Akdag O, Borman PTS, Mandija S, Woodhead PL, Uijtewaal P, Raaymakers BW, Fast MF. Experimental demonstration of real-time cardiac physiology-based radiotherapy gating for improved cardiac radioablation on an MR-linac. Med Phys 2024; 51:2354-2366. [PMID: 38477841 DOI: 10.1002/mp.17024] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/28/2023] [Revised: 02/09/2024] [Accepted: 02/23/2024] [Indexed: 03/14/2024] Open
Abstract
BACKGROUND Cardiac radioablation is a noninvasive stereotactic body radiation therapy (SBRT) technique to treat patients with refractory ventricular tachycardia (VT) by delivering a single high-dose fraction to the VT isthmus. Cardiorespiratory motion induces position uncertainties resulting in decreased dose conformality. Electocardiograms (ECG) are typically used during cardiac MRI (CMR) to acquire images in a predefined cardiac phase, thus mitigating cardiac motion during image acquisition. PURPOSE We demonstrate real-time cardiac physiology-based radiotherapy beam gating within a preset cardiac phase on an MR-linac. METHODS MR images were acquired in healthy volunteers (n = 5, mean age = 29.6 years, mean heart-rate (HR) = 56.2 bpm) on the 1.5 T Unity MR-linac (Elekta AB, Stockholm, Sweden) after obtaining written informed consent. The images were acquired using a single-slice balance steady-state free precession (bSSFP) sequence in the coronal or sagittal plane (TR/TE = 3/1.48 ms, flip angle = 48∘ $^{\circ }$ , SENSE = 1.5,field-of-view = 400 × 207 $\text{field-of-view} = {400}\times {207}$ mm 2 ${\text{mm}}^{2}$ , voxel size =3 × 3 × 15 $3\times 3\times 15$ mm 3 ${\rm mm}^{3}$ , partial Fourier factor = 0.65, frame rate = 13.3 Hz). In parallel, a 4-lead ECG-signal was acquired using MR-compatible equipment. The feasibility of ECG-based beam gating was demonstrated with a prototype gating workflow using a Quasar MRI4D motion phantom (IBA Quasar, London, ON, Canada), which was deployed in the bore of the MR-linac. Two volunteer-derived combined ECG-motion traces (n = 2, mean age = 26 years, mean HR = 57.4 bpm, peak-to-peak amplitude = 14.7 mm) were programmed into the phantom to mimic dose delivery on a cardiac target in breath-hold. Clinical ECG-equipment was connected to the phantom for ECG-voltage-streaming in real-time using research software. Treatment beam gating was performed in the quiescent phase (end-diastole). System latencies were compensated by delay time correction. A previously developed MRI-based gating workflow was used as a benchmark in this study. A 15-beam intensity-modulated radiotherapy (IMRT) plan (1 × 6.25 ${1}\times {6.25}$ Gy) was delivered for different motion scenarios onto radiochromic films. Next, cardiac motion was then estimated at the basal anterolateral myocardial wall via normalized cross-correlation-based template matching. The estimated motion signal was temporally aligned with the ECG-signal, which were then used for position- and ECG-based gating simulations in the cranial-caudal (CC), anterior-posterior (AP), and right-left (RL) directions. The effect of gating was investigated by analyzing the differences in residual motion at 30, 50, and 70% treatment beam duty cycles. RESULTS ECG-based (MRI-based) beam gating was performed with effective duty cycles of 60.5% (68.8%) and 47.7% (50.4%) with residual motion reductions of 62.5% (44.7%) and 43.9% (59.3%). Local gamma analyses (1%/1 mm) returned pass rates of 97.6% (94.1%) and 90.5% (98.3%) for gated scenarios, which exceed the pass rates of 70.3% and 82.0% for nongated scenarios, respectively. In average, the gating simulations returned maximum residual motion reductions of 88%, 74%, and 81% at 30%, 50%, and 70% duty cycles, respectively, in favor of MRI-based gating. CONCLUSIONS Real-time ECG-based beam gating is a feasible alternative to MRI-based gating, resulting in improved dose delivery in terms of highγ -pass $\gamma {\text{-pass}}$ rates, decreased dose deposition outside the PTV and residual motion reduction, while by-passing cardiac MRI challenges.
Collapse
Affiliation(s)
- Osman Akdag
- Department of Radiotherapy, University Medical Center Utrecht, Utrecht, The Netherlands
| | - Pim T S Borman
- Department of Radiotherapy, University Medical Center Utrecht, Utrecht, The Netherlands
| | - Stefano Mandija
- Department of Radiotherapy, University Medical Center Utrecht, Utrecht, The Netherlands
- Computational Imaging Group for MR Diagnostics and Therapy, Center for Image Sciences, University Medical Center Utrecht, Utrecht, The Netherlands
| | - Peter L Woodhead
- Department of Radiotherapy, University Medical Center Utrecht, Utrecht, The Netherlands
- Elekta AB, Stockholm, Sweden
| | - Prescilla Uijtewaal
- Department of Radiotherapy, University Medical Center Utrecht, Utrecht, The Netherlands
| | - Bas W Raaymakers
- Department of Radiotherapy, University Medical Center Utrecht, Utrecht, The Netherlands
| | - Martin F Fast
- Department of Radiotherapy, University Medical Center Utrecht, Utrecht, The Netherlands
| |
Collapse
|
2
|
Meier C, Eisenblätter M, Gielen S. Myocardial Late Gadolinium Enhancement (LGE) in Cardiac Magnetic Resonance Imaging (CMR)-An Important Risk Marker for Cardiac Disease. J Cardiovasc Dev Dis 2024; 11:40. [PMID: 38392254 PMCID: PMC10888577 DOI: 10.3390/jcdd11020040] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/12/2023] [Revised: 01/18/2024] [Accepted: 01/22/2024] [Indexed: 02/24/2024] Open
Abstract
Cardiovascular magnetic resonance (CMR) has significantly revolutionized the comprehension and diagnosis of cardiac diseases, particularly through the utilization of late gadolinium enhancement (LGE) imaging for tissue characterization. LGE enables the visualization of expanded extracellular spaces in conditions such as fibrosis, fibrofatty tissue, or edema. The growing recognition of LGE's prognostic capacity underscores its importance, evident in the increasing explicit recommendations within guidelines. Notably, the contemporary characterization of cardiomyopathies relies on LGE-based scar assessment by CMR to a large extent. This review describes the pattern and prognostic value of LGE in detail for various cardiac diseases. Despite its merits, establishing LGE as a reliable risk marker encounters challenges. Limitations arise from the fact that not all diseases show LGE, and it should always be analyzed in the context of all CMR sequences and the patient's medical history. In summary, LGE stands as a robust indicator of adverse outcomes in diverse cardiovascular diseases. Its further integration into routine practice is desirable, necessitating widespread availability and application to accumulate both individual and scientific experience.
Collapse
Affiliation(s)
- Claudia Meier
- Universitätsklinik für Kardiologie, Angiologie und Internistische Intensivmedizin, Universitätsklinikum Ostwestfalen-Lippe, Campus Klinikum Lippe, D-32756 Detmold, Germany
- Medizinische Fakultät, Universität Bielefeld, D-33615 Bielefeld, Germany
| | - Michel Eisenblätter
- Medizinische Fakultät, Universität Bielefeld, D-33615 Bielefeld, Germany
- Universitätsinstitut für Diagnostische und Interventionelle Radiologie, Universitätsklinikum Ostwestfalen-Lippe, Campus Klinikum Lippe, D-32756 Detmold, Germany
| | - Stephan Gielen
- Universitätsklinik für Kardiologie, Angiologie und Internistische Intensivmedizin, Universitätsklinikum Ostwestfalen-Lippe, Campus Klinikum Lippe, D-32756 Detmold, Germany
- Medizinische Fakultät, Universität Bielefeld, D-33615 Bielefeld, Germany
| |
Collapse
|
3
|
Kohli U, von Alvensleben J, Srinivasan C. Subcutaneous Implantable Cardioverter Defibrillators in Pediatrics and Congenital Heart Disease. Card Electrophysiol Clin 2023; 15:e1-e16. [PMID: 38030336 DOI: 10.1016/j.ccep.2023.09.002] [Citation(s) in RCA: 1] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/01/2023]
Abstract
Subcutaneous implantable cardioverter defibrillators (S-ICDs) are being used with increased frequency in children and patients with congenital heart disease. Vascular access complexities, intracardiac shunts, and specific anatomies make these devices particularly appealing for some of these patients. Alternative screening, implantation, and programming techniques should be considered based on patient size, body habitus, anatomy, procedural history, and preference. Appropriate and inappropriate shock rates are generally comparable to those seen with transvenous devices. Complications such as infection can occur, although their severity is likely to be less than that seen with transvenous devices. Technical advances are likely to further broaden S-ICD applicability.
Collapse
Affiliation(s)
- Utkarsh Kohli
- Division of Pediatric Cardiology, Department of Pediatrics, West Virginia University School of Medicine and West Virginia University Children's Heart Center, 64 Medical Center Drive, Robert C. Byrd Health Science Center, PO Box 9214, Morgantown, WV 26506-9214, USA.
| | - Johannes von Alvensleben
- Children's Hospital Colorado, University of Colorado School of Medicine, 13123 East 16th Avenue, Aurora, CO 80045 720-777-1234, USA
| | - Chandra Srinivasan
- The Children's Hospital of Philadelphia; University of Perelman School of Medicine, 3401 Civic Center Boulevard, Philadelphia, PA 19104, USA
| |
Collapse
|
4
|
Korthals D, Eckardt L. The new European Society of Cardiology guideline for the management of cardiomyopathies: key messages for cardiac electrophysiologists. Herzschrittmacherther Elektrophysiol 2023; 34:311-323. [PMID: 37973628 PMCID: PMC10682323 DOI: 10.1007/s00399-023-00975-y] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/29/2023] [Accepted: 10/04/2023] [Indexed: 11/19/2023]
Abstract
Electrocardiographic findings and arrhythmias are common in cardiomyopathies. Both may be an early indication of a specific diagnosis or may occur due to myocardial fibrosis and/or reduced contractility. Brady- and tachyarrhythmias significantly contribute to increased morbidity and mortality in patients with cardiomyopathies. Antiarrhythmic therapy including risk stratification is often challenging and plays a major role for these patients. Thus, an "electrophysiological" perspective on guidelines on cardiomyopathies may be warranted. As the European Society of Cardiology (ESC) has recently published a new guideline for the management of cardiomyopathies, this overview aims to present key messages of these guidelines. Innovations include a new phenotype-based classification system with emphasis on a multimodal imaging approach for diagnosis and risk stratification. The guideline includes detailed chapters on dilated and hypertrophic cardiomyopathy and their phenocopies, arrhythmogenic right ventricular cardiomyopathy, and restrictive cardiomyopathy as well as syndromic and metabolic cardiomyopathies. Patient pathways guide clinicians from the initial presentation to diagnosis. The role of cardiovascular magnetic resonance imaging and genetic testing during diagnostic work-up is stressed. Concepts of rhythm and rate control for atrial fibrillation have led to new recommendations, and the role of defibrillator therapy in primary prevention is discussed in detail. Whilst providing general guidelines for management, the primary objective of the guideline is to ascertain the disease etiology and disease-specific, individualized management.
Collapse
Affiliation(s)
- Dennis Korthals
- Department of Cardiology II: Electrophysiology, University Hospital Münster, Albert-Schweitzer-Campus 1, 48149, Münster, Germany.
| | - Lars Eckardt
- Department of Cardiology II: Electrophysiology, University Hospital Münster, Albert-Schweitzer-Campus 1, 48149, Münster, Germany
| |
Collapse
|
5
|
Xiang J, Lamy J, Lampert R, Peters DC. Balanced Steady-State Free Precession Cine MR Imaging in the Presence of Cardiac Devices: Value of Interleaved Radial Linear Combination Acquisition With Partial Dephasing. J Magn Reson Imaging 2023; 58:782-791. [PMID: 36373998 DOI: 10.1002/jmri.28528] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/27/2022] [Revised: 10/31/2022] [Accepted: 11/01/2022] [Indexed: 11/16/2022] Open
Abstract
BACKGROUND Balanced steady-state free precession (bSSFP) is important in cardiac MRI but suffers from off-resonance artifacts. The interpretation-limiting artifacts in patients with cardiac implants remain an unsolved issue. PURPOSE To develop an interleaved radial linear combination bSSFP (lcSSFP) method with partial dephasing (PD) for improved cardiac cine imaging when implanted cardiovascular devices are present. STUDY TYPE Prospective. PHANTOM AND SUBJECTS Flow phantom adjacent to a pacemaker and 10 healthy volunteers (mean age ± standard deviation: 31.9 ± 2.9 years, 4 females) with a cardioverter-defibrillator (ICD) positioned extracorporeally at the left chest in the prepectoral region. FIELD STRENGTH/SEQUENCE A 3-T, 1) Cartesian bSSFP, 2) Cartesian gradient echo (GRE), 3) Cartesian lcSSFP, and 4) radial lcSSFP cine sequences. ASSESSMENT Flow artifacts mitigation using PD was validated with phantom experiments. Undersampled radial lcSSFP with interleaving across phase-cyclings and cardiac phases (RLC-SSFP), combined with PD, was then employed for achieving improved quality of cine images from left ventricular short-axis view. The image quality in the presence of cardiac devices was qualitatively assessed by three independent raters (1 = worst, 5 = best), regarding five criteria (banding artifacts, streak artifacts, flow artifacts, cavity visibility, and overall image quality). STATISTICAL TESTS Wilcoxon rank-sum test for the five criteria between Cartesian bSSFP cine and RLC-SSFP with PD. Fleiss kappa test for inter-reader agreement. A P value < 0.05 was considered statistically significant. RESULTS Based on simulations and phantom experiments, 60 projections per phase cycling and 1/6 PD were chosen. The in vivo experiments demonstrated significantly reduced banding artifacts (4.8 ± 0.4 vs. 2.7 ± 0.7), fewer streak artifacts (3.7 ± 0.6 vs. 2.6 ± 0.7) and flow artifacts (4.4 ± 0.4 vs. 3.7 ± 0.6), therefore improved cavity visibility (4.1 ± 0.4 vs. 2.9 ± 0.9) and overall quality (4.0 ± 0.4 vs. 2.7 ± 0.7). DATA CONCLUSION RLC-SSFP method with PD may improve cine image quality in subjects with cardiac devices. EVIDENCE LEVEL 2. TECHNICAL EFFICACY Stage 1.
Collapse
Affiliation(s)
- Jie Xiang
- Department of Biomedical Engineering, Yale University, New Haven, Connecticut, USA
| | - Jerome Lamy
- Department of Radiology and Biomedical Imaging, Yale University, New Haven, Connecticut, USA
| | - Rachel Lampert
- Department of Medicine, Cardiovascular Division, Yale University, New Haven, Connecticut, USA
| | - Dana C Peters
- Department of Biomedical Engineering, Yale University, New Haven, Connecticut, USA
- Department of Radiology and Biomedical Imaging, Yale University, New Haven, Connecticut, USA
| |
Collapse
|
6
|
Manning WJ. 2021 - State of our JCMR. J Cardiovasc Magn Reson 2022; 24:14. [PMID: 35246157 PMCID: PMC8896069 DOI: 10.1186/s12968-021-00840-2] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/09/2021] [Accepted: 12/14/2021] [Indexed: 11/10/2022] Open
Abstract
There were 89 articles published in the Journal of Cardiovascular Magnetic Resonance (JCMR) in 2020, including 71 original research papers, 5 technical notes, 6 reviews, 4 Society for Cardiovascular Magnetic Resonance (SCMR) position papers/guidelines/protocols and 3 corrections. The volume was up 12.7% from 2019 (n = 79) with a corresponding 17.9% increase in manuscript submissions from 369 to 435. This led to a slight increase in the acceptance rate from 22 to 23%. The quality of the submissions continues to be high. The 2020 JCMR Impact Factor (which is published in June 2020) slightly increased from 5.361 to 5.364 placing us in the top quartile of Society and cardiac imaging journals. Our 5 year impact factor increased from 5.18 to 6.52. Fourteen years ago, the JCMR was at the forefront of medical and medical society journal migration to the Open-Access format. The Open-Access system has dramatically increased the availability and citation of JCMR publications with accesses now exceeding 1.2 M! It takes a village to run a journal. JCMR is blessed to have a group of very dedicated Associate Editors, Guest Editors, Journal Club Editors, and Reviewers. I thank each of them for their efforts to ensure that the review process occurs in a timely and responsible manner. These efforts have allowed the JCMR to continue as the premier journal of our field. My role, and the entire process would not be possible without the dedication and efforts of our new managing editor, Jennifer Rodriguez, whose premier organizational efforts have allowed for streamlining of the review process and marked improvement in our time-to-decision (see later). As I begin my 6th and final year as your editor-in-chief, I thank you for entrusting me with the JCMR editorship. I hope that you will continue to send us your very best, high quality manuscripts for JCMR consideration and that our readers will continue to look to JCMR for the very best/state-of-the-art CMR publications. The editorial process continues to be a tremendously fulfilling experience and the opportunity to review manuscripts that reflect the best in our field remains a great joy and true highlight of my week!
Collapse
Affiliation(s)
- Warren J Manning
- Departments of Medicine (Cardiovascular Division) and Radiology, Beth Israel Deaconess Medical Center, Harvard Medical School, Boston, Massachusetts, 02215, USA.
- JCMR Editorial Office, Boston, Massachusetts, 02215, USA.
| |
Collapse
|
7
|
Ian Paterson D, White JA, Butler CR, Connelly KA, Guerra PG, Hill MD, James MT, Kirpalani A, Lydell CP, Roifman I, Sarak B, Sterns LD, Verma A, Wan D, Crean AM, Grosse-Wortmann L, Hanneman K, Leipsic J, Manlucu J, Nguyen ET, Sandhu RK, Villemaire C, Wald RM, Windram J. 2021 Update on Safety of Magnetic Resonance Imaging: Joint Statement From Canadian Cardiovascular Society/Canadian Society for Cardiovascular Magnetic Resonance/Canadian Heart Rhythm Society. Can J Cardiol 2021; 37:835-847. [PMID: 34154798 DOI: 10.1016/j.cjca.2021.02.012] [Citation(s) in RCA: 9] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/27/2020] [Revised: 02/15/2021] [Accepted: 02/18/2021] [Indexed: 11/30/2022] Open
Abstract
Magnetic resonance imaging (MRI) is often considered the gold-standard test for characterizing cardiac as well as noncardiac structure and function. However, many patients with cardiac implantable electronic devices (CIEDs) and/or severe renal dysfunction are unable to undergo this test because of safety concerns. In the past 10 years, newer-generation CIEDs and gadolinium-based contrast agents (GBCAs) as well as coordinated care between imaging and heart rhythm device teams have mitigated risk to patients and improved access to MRI at many hospitals. The purpose of this statement is to review published data on safety of MRI in patients with conditional and nonconditional CIEDs in addition to patient risks from older and newer GBCAs. This statement was developed through multidisciplinary collaboration of pan-Canadian experts after a relevant and independent literature search by the Canadian Agency for Drugs and Technologies in Health. All recommendations align with the Grading of Recommendations Assessment, Development and Evaluation (GRADE) system. Key recommendations include: (1) the development of standardized protocols for patients with a CIED undergoing MRI; (2) patients with MRI nonconditional pacemakers and pacemaker dependency should be programmed to asynchronous mode and those with MRI nonconditional transvenous defibrillators should have tachycardia therapies turned off during the scan; and (3) macrocyclic or newer linear GBCAs should be used in preference to older GBCAs because of their better safety profile in patients at higher risk of nephrogenic systemic fibrosis.
Collapse
Affiliation(s)
| | - D Ian Paterson
- Mazankowski Alberta Heart Institute, University of Alberta, Edmonton, Alberta, Canada.
| | - James A White
- Calgary Foothills Medical Centre, University of Calgary, Calgary, Alberta, Canada
| | - Craig R Butler
- Mazankowski Alberta Heart Institute, University of Alberta, Edmonton, Alberta, Canada
| | - Kim A Connelly
- St Michael's Hospital, University of Toronto, Toronto, Ontario, Canada
| | - Peter G Guerra
- Institut de Cardiologie de Montréal, Université de Montréal, Montréal, Québec, Canada
| | - Michael D Hill
- Calgary Foothills Medical Centre, University of Calgary, Calgary, Alberta, Canada
| | - Matthew T James
- Calgary Foothills Medical Centre, University of Calgary, Calgary, Alberta, Canada
| | - Anish Kirpalani
- St Michael's Hospital, University of Toronto, Toronto, Ontario, Canada
| | - Carmen P Lydell
- Calgary Foothills Medical Centre, University of Calgary, Calgary, Alberta, Canada
| | - Idan Roifman
- Sunnybrook Health Sciences Centre, University of Toronto, Toronto, Ontario, Canada
| | - Bradley Sarak
- St Michael's Hospital, University of Toronto, Toronto, Ontario, Canada
| | - Laurence D Sterns
- Royal Jubilee Hospital, University of British Columbia, Victoria, British Columbia, Canada
| | - Atul Verma
- Southlake Regional Health Centre, Newmarket, Ontario, Canada
| | - Douglas Wan
- Sunnybrook Health Sciences Centre, University of Toronto, Toronto, Ontario, Canada
| | | | - Andrew M Crean
- Ottawa Heart Institute, University of Ottawa, Ottawa, Ontario, Canada
| | - Lars Grosse-Wortmann
- Doernbecher Children's Hospital, Oregon Health and Science University, Portland, Oregon, USA
| | - Kate Hanneman
- Toronto General Hospital, University of Toronto, Toronto, Ontario, Canada
| | - Jonathon Leipsic
- St Paul's Hospital, University of British Columbia, Vancouver, British Columbia, Canada
| | - Jaimie Manlucu
- London Health Sciences Centre, Western University, London, Ontario, Canada
| | - Elsie T Nguyen
- Doernbecher Children's Hospital, Oregon Health and Science University, Portland, Oregon, USA
| | - Roopinder K Sandhu
- Mazankowski Alberta Heart Institute, University of Alberta, Edmonton, Alberta, Canada
| | - Christine Villemaire
- Institut de Cardiologie de Montréal, Université de Montréal, Montréal, Québec, Canada
| | - Rachel M Wald
- Mount Sinai Hospital, University of Toronto, Toronto, Ontario, Canada
| | - Jonathan Windram
- Mazankowski Alberta Heart Institute, University of Alberta, Edmonton, Alberta, Canada
| |
Collapse
|
8
|
Follow up after atrial switch surgery in patients with transposition of the great arteries; reality versus guidelines. INTERNATIONAL JOURNAL OF CARDIOLOGY CONGENITAL HEART DISEASE 2021. [DOI: 10.1016/j.ijcchd.2021.100123] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/19/2022] Open
|
9
|
Singh A, Chen W, Patel HN, Alvi N, Kawaji K, Besser SA, Tung R, Zou J, Lang RM, Mor-Avi V, Patel AR. Impact of Wideband Late Gadolinium Enhancement Cardiac Magnetic Resonance Imaging on Device-Related Artifacts in Different Implantable Cardioverter-Defibrillator Types. J Magn Reson Imaging 2021; 54:1257-1265. [PMID: 33742522 DOI: 10.1002/jmri.27608] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/03/2020] [Revised: 03/05/2021] [Accepted: 03/10/2021] [Indexed: 02/05/2023] Open
Abstract
BACKGROUND Late gadolinium enhancement (LGE) imaging in patients with implantable cardioverter-defibrillators (ICD) is limited by device-related artifacts (DRA). The use of wideband (WB) LGE protocols improves LGE images, but their efficacy with different ICD types is not well known. PURPOSE To assess the effects of WB LGE imaging on DRA in different non-MR conditional ICD subtypes. STUDY TYPE Retrospective. POPULATION A total of 113 patients undergoing cardiac magnetic resonance imaging with three ICD subtypes: transvenous (TV-ICD, N = 48), cardiac-resynchronization therapy device (CRT-D, N = 48), and subcutaneous (S-ICD, N = 17). FIELD STRENGTH/SEQUENCE 5 T scanner, standard LGE, and WB LGE imaging with a phase-sensitive inversion recovery segmented gradient echo sequence. ASSESSMENT DRA burden was defined as the number of artifact-positive short-axis LGE slices as percentage of the total number of short-axis slices covering the left ventricle from based to apex, and was determined for WB and standard LGE studies for each patient. Additionally, artifact area on each slice was quantified. STATISTICAL TESTS Shapiro-Wilks, Kruskal-Wallis analysis of variance, Dunn tests with Bonferroni correction, and Mann-Whitney U-test. RESULTS In patients with TV-ICD, DRA burden was significantly reduced and nearly eliminated with WB LGE compared to standard LGE imaging (median [interquartile range]: 0 [0-7]% vs. 18 [0-50]%, P < 0.05), but WB imaging had less of an impact on DRA in the CRT-D (8 [0-23]% vs. 16 [0-45]%, p = 0.12) and S-ICD (60 [15-71]% vs. 67 [50-92]%, P = 0.09) patients. Residual DRA was significantly greater (P < 0.05) for S-ICD compared to other device types with WB LGE imaging, despite the generators of all three ICD types having similar proximity to the heart. The area of S-ICD associated DRA was smaller with WB LGE (P < 0.001) than with standard LGE imaging and the artifacts had different characteristics (dark signal void instead of a bright hyperenhancement artifact). DATA CONCLUSION Although WB LGE imaging reduced the burden of DRA caused by S-ICD, the residual artifact was greater than that observed with TV-ICD and CRT-D devices. Further developments are needed to better resolve S-ICD artifacts. LEVEL OF EVIDENCE 1 TECHNICAL EFFICACY: STAGE: 5.
Collapse
Affiliation(s)
- Amita Singh
- Department of Medicine, Section of Cardiology, University of Chicago Medicine, Chicago, Illinois, USA
| | - Wensu Chen
- Department of Medicine, Section of Cardiology, University of Chicago Medicine, Chicago, Illinois, USA.,Cardiology Department, First Affiliated Hospital, Nanjing Medical University, Nanjing, China
| | - Hena N Patel
- Department of Medicine, Section of Cardiology, University of Chicago Medicine, Chicago, Illinois, USA
| | - Nazia Alvi
- Department of Medicine, Section of Cardiology, University of Chicago Medicine, Chicago, Illinois, USA
| | - Keigo Kawaji
- Department of Medicine, Section of Cardiology, University of Chicago Medicine, Chicago, Illinois, USA.,Department of Biomedical Engineering, Illinois Institute of Technology, Chicago, Illinois, USA
| | - Stephanie A Besser
- Department of Medicine, Section of Cardiology, University of Chicago Medicine, Chicago, Illinois, USA
| | - Roderick Tung
- Department of Medicine, Section of Cardiology, University of Chicago Medicine, Chicago, Illinois, USA
| | - Jiangang Zou
- Cardiology Department, First Affiliated Hospital, Nanjing Medical University, Nanjing, China
| | - Roberto M Lang
- Department of Medicine, Section of Cardiology, University of Chicago Medicine, Chicago, Illinois, USA
| | - Victor Mor-Avi
- Department of Medicine, Section of Cardiology, University of Chicago Medicine, Chicago, Illinois, USA
| | - Amit R Patel
- Department of Medicine, Section of Cardiology, University of Chicago Medicine, Chicago, Illinois, USA
| |
Collapse
|
10
|
Schwartz SM, Pathrose A, Serhal AM, Ragin AB, Charron J, Knight BP, Passman RS, Avery RJ, Kim D. Evaluation of image quality of wideband single-shot late gadolinium-enhancement MRI in patients with a cardiac implantable electronic device. J Cardiovasc Electrophysiol 2020; 32:138-147. [PMID: 33146422 DOI: 10.1111/jce.14798] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 08/01/2020] [Revised: 10/05/2020] [Accepted: 10/07/2020] [Indexed: 12/12/2022]
Abstract
INTRODUCTION While wideband segmented, breath-hold late gadolinium-enhancement (LGE) cardiovascular magnetic resonance (CMR) has been shown to suppress image artifacts associated with cardiac-implanted electronic devices (CIEDs), it may produce image artifacts in patients with arrhythmia and/or dyspnea. Single-shot LGE is capable of suppressing said artifacts. We sought to compare the performance of wideband single-shot free-breathing LGE against the standard and wideband-segmented LGEs in CIED patients. METHODS AND RESULTS We retrospectively identified all 54 consecutive patients (mean age: 61 ± 15 years; 31% females) with CIED who had undergone CMR with standard segmented, wideband segmented, and/or wideband single-shot LGE sequences as part of quality assurance for determining best clinical practice at 1.5 T. Two raters independently graded the conspicuity of myocardial scar or normal myocardium and the presence of device artifact level on a 5-point Likert scale (1: worst; 3: acceptable; 5: best). Summed visual score (SVS) was calculated as the sum of conspicuity and artifact scores (SVS ≥ 6 defined as diagnostically interpretable). Median conspicuity and artifact scores were significantly better for wideband single-shot LGE (F = 24.2, p < .001) and wideband-segmented LGE (F = 20.6, p < .001) compared to standard-segmented LGE. Among evaluated myocardial segments, 72% were deemed diagnostically interpretable-defined as SVS ≥ 6-for standard-segmented LGE, 89% were deemed diagnostically interpretable for wideband-segmented LGE, and 94% segments were deemed diagnostically interpretable for wideband single-shot LGE. CONCLUSIONS Wideband single-shot LGE and wideband-segmented LGE produced similarly improved image quality compared to standard LGE.
Collapse
Affiliation(s)
- Sarah M Schwartz
- Department of Radiology, Northwestern University Feinberg School of Medicine, Chicago, Illinois, USA
| | - Ashitha Pathrose
- Department of Radiology, Northwestern University Feinberg School of Medicine, Chicago, Illinois, USA
| | - Ali M Serhal
- Department of Radiology, Northwestern University Feinberg School of Medicine, Chicago, Illinois, USA
| | - Ann B Ragin
- Department of Radiology, Northwestern University Feinberg School of Medicine, Chicago, Illinois, USA
| | - Jessica Charron
- Department of Internal Medicine, Division of Cardiology, Northwestern University Feinberg School of Medicine, Chicago, Illinois, USA
| | - Bradley P Knight
- Department of Internal Medicine, Division of Cardiology, Northwestern University Feinberg School of Medicine, Chicago, Illinois, USA
| | - Rod S Passman
- Department of Internal Medicine, Division of Cardiology, Northwestern University Feinberg School of Medicine, Chicago, Illinois, USA
| | - Ryan J Avery
- Department of Radiology, Northwestern University Feinberg School of Medicine, Chicago, Illinois, USA
| | - Daniel Kim
- Department of Radiology, Northwestern University Feinberg School of Medicine, Chicago, Illinois, USA
| |
Collapse
|