1
|
Yoo M, Chun MH, Hong GR, Lee C, Lee JK, Lee A. Effects of Training with a Powered Exoskeleton on Cortical Activity Modulation in Hemiparetic Chronic Stroke Patients: A Randomized Controlled Pilot Trial. Arch Phys Med Rehabil 2023; 104:1620-1629. [PMID: 37295705 DOI: 10.1016/j.apmr.2023.05.012] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/02/2022] [Revised: 04/26/2023] [Accepted: 05/25/2023] [Indexed: 06/12/2023]
Abstract
OBJECTIVES To investigate the effects of exoskeleton-assisted gait training in stroke patients. DESIGN Prospective randomized controlled trial. SETTING Rehabilitation department in a single tertiary hospital. PARTICIPANTS Thirty (N=30) chronic stroke patients with Functional Ambulatory Category scale (FAC) between 2 and 4. INTERVENTION Patients were randomly assigned to 1 of 2 groups: training with Healbot G, a wearable powered exoskeleton (Healbot G group; n=15), or treadmill training (control group; n=15). All participants received 30 minutes of training, 10 times per week, for 4 weeks. OUTCOME MEASUREMENTS The primary outcome was oxyhemoglobin level changes, representing cortical activity in both motor cortices using functional near-infrared spectroscopy. The secondary outcomes included FAC, Berg Balance Scale, Motricity Index for the lower extremities (MI-Lower), 10-meter walk test, and gait symmetry ratio (spatial step and temporal symmetry ratio). RESULTS Compared to the control group, during the entire training session, the pre-training and post-training mean cortical activity, and the amount of increment between pre- and post-training were significantly higher in the Healbot G group (∆mean ± SD; pre-training, 0.245±0.119, post-training, 0.697±0.429, between pre- and post-training, 0.471±0.401μmol, P<.001). There was no significant difference in cortical activity between affected- and unaffected hemispheres after Healbot G training. FAC (∆mean ± SD; 0.35 ± 0.50, P=.012), MI-Lower (∆mean ± SD; 7.01 ± 0.14, P=.001), and spatial step gait symmetry ratio (∆mean ± SD; -0.32 ± 0.25, P=.049) were improved significantly in the Healbot G group. CONCLUSION Exoskeleton-assisted gait training induces cortical modulation effect in both motor cortices, a balanced cortical activation pattern with improvements in spatial step symmetry ratio, walking ability, and voluntary strength.
Collapse
Affiliation(s)
- Miran Yoo
- Department of Rehabilitation Medicine, Asan Medical Center, University of Ulsan College of Medicine, Seoul, Republic of Korea
| | - Min Ho Chun
- Department of Rehabilitation Medicine, Asan Medical Center, University of Ulsan College of Medicine, Seoul, Republic of Korea.
| | - Ga Ram Hong
- Department of Rehabilitation Medicine, Asan Medical Center, University of Ulsan College of Medicine, Seoul, Republic of Korea
| | - Changmin Lee
- School of Electrical and Electronic Engineering, Yonsei University, Seoul, Republic of Korea
| | - June Kyoung Lee
- Department of Rehabilitation Medicine, Hallym University Dongtan Sacred Heart Hospital, Hallym University College of Medicine, Hwaseong, Gyeonggi-do, Republic of Korea
| | - Anna Lee
- Department of Rehabilitation Medicine, Asan Medical Center, University of Ulsan College of Medicine, Seoul, Republic of Korea
| |
Collapse
|
2
|
Kim J, Oh S, Jo Y, Moon JH, Kim J. A robotic treadmill system to mimic overground walking training with body weight support. Front Neurorobot 2023; 17:1089377. [PMID: 37359910 PMCID: PMC10288878 DOI: 10.3389/fnbot.2023.1089377] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/04/2022] [Accepted: 02/21/2023] [Indexed: 06/28/2023] Open
Abstract
Introduction Body weight support overground walking training (BWSOWT) is widely used in gait rehabilitation. However, existing systems require large workspace, complex structure, and substantial installation cost for the actuator, which make those systems inappropriate for the clinical environment. For wide clinical use, the proposed system is based on a self-paced treadmill, and uses an optimized body weight support with frame-based two-wire mechanism. Method The Interactive treadmill was used to mimic overground walking. We opted the conventional DC motors to partially unload the body weight and modified pelvic type harness to allow natural pelvic motion. The performance of the proposed system on the measurement of anterior/posterior position, force control, and pelvic motion was evaluated with 8 healthy subjects during walking training. Results We verified that the proposed system was the cost/space-effective and showed the more accurate anterior/posterior position than motion sensor, comparable force control performance, and natural pelvic motion. Discussion The proposed system is cost/space effective, and able to mimic overground walking training with body weight support. In future work, we will improve the force control performance and optimize the training protocol for wide clinical use.
Collapse
Affiliation(s)
- Jongbum Kim
- Department of Robotics and Mechatronics Engineering, Daegu Gyeongbuk Institute of Science and Technology (DGIST), Daegu, Republic of Korea
| | - Seunghue Oh
- Department of Physical Therapy, Uiduk University, Gyeongju-si, Republic of Korea
| | - Yongjin Jo
- Department of Mechanical Engineering, Sungkyunkwan University, Suwon-si, Republic of Korea
| | - James Hyungsup Moon
- Department of Mechanical Engineering, Sungkyunkwan University, Suwon-si, Republic of Korea
| | - Jonghyun Kim
- Department of Mechanical Engineering, Sungkyunkwan University, Suwon-si, Republic of Korea
| |
Collapse
|
3
|
Zheng J, He W, Ma Q, Cai W, Li S, Yu H. Cortical activation in robot-assisted dynamic and static resistance training combining VR interaction: An fNIRS based pilot study. NeuroRehabilitation 2023; 52:413-423. [PMID: 36806524 DOI: 10.3233/nre-220292] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/19/2023]
Abstract
BACKGROUND There are few isometric training systems based on upper limb rehabilitation robots. Its efficacy and neural mechanism are not well understood. OBJECTIVE This study aims to investigate the cortex activation of dynamic resistance and static (isometric) training based on upper limb rehabilitation robot combined with virtual reality (VR) interaction by using functional near-infrared spectroscopy (fNIRS). METHODS Twenty subjects were included in this study. The experiment adopts the block paradigm design. Experiment in dynamic and static conditions consisted of three trials, each consisting of task (60 s)-rest (40 s). The neural activities of the sensorimotor cortex (SMC), premotor cortex (PMC) and prefrontal cortex (PFC) were measured. The cortex activation and functional connectivity (FC) were analyzed. RESULTS Both the dynamic and static training can activate SMC, PMC, and PFC. In SMC and PMC, the activation of static training was stronger than dynamic training, there were significant differences between the two modes of each region of interest (ROI) (p < 0.05) (SMC: p = 0.022, ES = 0.72, PMC: p = 0.039, ES = 0.63). Besides, the FC between all ROIs of the static training was stronger than that of the dynamic training. CONCLUSION The static training based on upper limb rehabilitation robot may better facilitate the cortical activation associated with motor control.
Collapse
Affiliation(s)
- Jinyu Zheng
- Institute of Rehabilitation Engineering and Technology, University of Shanghai for Science and Technology, Shanghai, China.,Shanghai Engineering Research Center of Assistive Devices, Shanghai, China
| | - Wanying He
- Institute of Rehabilitation Engineering and Technology, University of Shanghai for Science and Technology, Shanghai, China.,Shanghai Engineering Research Center of Assistive Devices, Shanghai, China
| | - Qiqi Ma
- Institute of Rehabilitation Engineering and Technology, University of Shanghai for Science and Technology, Shanghai, China.,Shanghai Engineering Research Center of Assistive Devices, Shanghai, China
| | - Wenqian Cai
- Institute of Rehabilitation Engineering and Technology, University of Shanghai for Science and Technology, Shanghai, China.,Shanghai Engineering Research Center of Assistive Devices, Shanghai, China
| | - Sujiao Li
- Institute of Rehabilitation Engineering and Technology, University of Shanghai for Science and Technology, Shanghai, China.,Shanghai Engineering Research Center of Assistive Devices, Shanghai, China.,Key Laboratory of Neural-Functional Information and Rehabilitation Engineering of the Ministry of Civil Affairs, Shanghai, China
| | - Hongliu Yu
- Institute of Rehabilitation Engineering and Technology, University of Shanghai for Science and Technology, Shanghai, China.,Shanghai Engineering Research Center of Assistive Devices, Shanghai, China.,Key Laboratory of Neural-Functional Information and Rehabilitation Engineering of the Ministry of Civil Affairs, Shanghai, China
| |
Collapse
|
4
|
Relation between Cortical Activation and Effort during Robot-Mediated Walking in Healthy People: A Functional Near-Infrared Spectroscopy Neuroimaging Study (fNIRS). SENSORS 2022; 22:s22155542. [PMID: 35898041 PMCID: PMC9329983 DOI: 10.3390/s22155542] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 06/20/2022] [Revised: 07/19/2022] [Accepted: 07/22/2022] [Indexed: 02/01/2023]
Abstract
Force and effort are important components of a motor task that can impact rehabilitation effectiveness. However, few studies have evaluated the impact of these factors on cortical activation during gait. The purpose of the study was to investigate the relation between cortical activation and effort required during exoskeleton-mediated gait at different levels of physical assistance in healthy individuals. Twenty-four healthy participants walked 10 m with an exoskeleton that provided four levels of assistance: 100%, 50%, 0%, and 25% resistance. Functional near-infrared spectroscopy (fNIRS) was used to measure cerebral flow dynamics with a 20-channel (plus two reference channels) device that covered most cortical motor regions bilaterally. We measured changes in oxyhemoglobin (HbO2) and deoxyhemoglobin (HbR). According to HbO2 levels, cortical activation only differed slightly between the assisted conditions and rest. In contrast, bilateral and widespread cortical activation occurred during the two unassisted conditions (somatosensory, somatosensory association, primary motor, premotor, and supplementary motor cortices). A similar pattern was seen for HbR levels, with a smaller number of significant channels than for HbO2. These results confirmed the hypothesis that there is a relation between cortical activation and level of effort during gait. This finding should help to optimize neurological rehabilitation strategies to drive neuroplasticity.
Collapse
|
5
|
Song KJ, Chun MH, Lee J, Lee C. The effect of robot-assisted gait training on cortical activation in stroke patients: A functional near-infrared spectroscopy study. NeuroRehabilitation 2021; 49:65-73. [PMID: 33998555 DOI: 10.3233/nre-210034] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/15/2022]
Abstract
OBJECTIVE To investigate the effects of the robot-assisted gait training on cortical activation and functional outcomes in stroke patients. METHODS The patients were randomly assigned: training with Morning Walk® (Morning Walk group; n = 30); conventional physiotherapy (control group; n = 30). Rehabilitation was performed five times a week for 3 weeks. The primary outcome was the cortical activation in the Morning Walk group. The secondary outcomes included gait speed, 10-Meter Walk Test (10MWT), FAC, Motricity Index-Lower (MI-Lower), Modified Barthel Index (MBI), Rivermead Mobility Index (RMI), and Berg Balance Scale (BBS). RESULTS Thirty-six subjects were analyzed, 18 in the Morning Walk group and 18 in the control group. The cortical activation was lower in affected hemisphere than unaffected hemisphere at the beginning of robot rehabilitation. After training, the affected hemisphere achieved a higher increase in cortical activation than the unaffected hemisphere. Consequently, the cortical activation in affected hemisphere was significantly higher than that in unaffected hemisphere (P = 0.036). FAC, MBI, BBS, and RMI scores significantly improved in both groups. The Morning Walk group had significantly greater improvements than the control group in 10MWT (P = 0.017), gait speed (P = 0.043), BBS (P = 0.010), and MI-Lower (P = 0.047) scores. CONCLUSION Robot-assisted gait training not only improved functional outcomes but also increased cortical activation in stroke patients.
Collapse
Affiliation(s)
- Kyeong Joo Song
- Department of Rehabilitation Medicine, Asan Medical Center, University of Ulsan College of Medicine, Seoul, Republic of Korea
| | - Min Ho Chun
- Department of Rehabilitation Medicine, Asan Medical Center, University of Ulsan College of Medicine, Seoul, Republic of Korea
| | - Junekyung Lee
- Department of Rehabilitation Medicine, Hallym University Dongtan Sacred Heart Hospital, Hallym University College of Medicine, Hwaseong, Republic of Korea
| | - Changmin Lee
- BK21-Y-BASE R&E Institute, School of Electrical and Electronic Engineering, Yonsei University, Seoul, Republic of Korea
| |
Collapse
|
6
|
Effects of passive and active training modes of upper-limb rehabilitation robot on cortical activation: a functional near-infrared spectroscopy study. Neuroreport 2021; 32:479-488. [PMID: 33788815 DOI: 10.1097/wnr.0000000000001615] [Citation(s) in RCA: 10] [Impact Index Per Article: 3.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/04/2023]
Abstract
OBJECTIVE The purpose of this study is to investigate the cortical activation during passive and active training modes under different speeds of upper extremity rehabilitation robots. METHODS Twelve healthy subjects completed the active and passive training modes at various speeds (0.12, 0.18, and 0.24 m/s) for the right upper limb. The functional near-infrared spectroscopy (fNIRS) was used to measure the neural activities of the sensorimotor cortex (SMC), premotor cortex (PMC), supplementary motor area (SMA), and prefrontal cortex (PFC). RESULTS Both the active and passive training modes can activate SMC, PMC, SMA, and PFC. The activation level of active training is higher than that of passive training. At the speed of 0.12 m/s, there is no significant difference in the intensity of the two modes. However, at the speed of 0.24 m/s, there are significant differences between the two modes in activation levels of each region of interest (ROI) (P < 0.05) (SMC: F = 8.90, P = 0.003; PMC: F = 8.26, P = 0.005; SMA: F = 5.53, P = 0.023; PFC: F = 9.160, P = 0.003). CONCLUSION This study mainly studied on the neural mechanisms of active and passive training modes at different speeds based on the end-effector upper-limb rehabilitation robot. Slow, active training better facilitated the cortical activation associated with cognition and motor control.See Video Abstract, http://links.lww.com/WNR/A621.
Collapse
|
7
|
Asgher U, Khan MJ, Asif Nizami MH, Khalil K, Ahmad R, Ayaz Y, Naseer N. Motor Training Using Mental Workload (MWL) With an Assistive Soft Exoskeleton System: A Functional Near-Infrared Spectroscopy (fNIRS) Study for Brain-Machine Interface (BMI). Front Neurorobot 2021; 15:605751. [PMID: 33815084 PMCID: PMC8012849 DOI: 10.3389/fnbot.2021.605751] [Citation(s) in RCA: 9] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/13/2020] [Accepted: 02/05/2021] [Indexed: 11/24/2022] Open
Abstract
Mental workload is a neuroergonomic human factor, which is widely used in planning a system's safety and areas like brain-machine interface (BMI), neurofeedback, and assistive technologies. Robotic prosthetics methodologies are employed for assisting hemiplegic patients in performing routine activities. Assistive technologies' design and operation are required to have an easy interface with the brain with fewer protocols, in an attempt to optimize mobility and autonomy. The possible answer to these design questions may lie in neuroergonomics coupled with BMI systems. In this study, two human factors are addressed: designing a lightweight wearable robotic exoskeleton hand that is used to assist the potential stroke patients with an integrated portable brain interface using mental workload (MWL) signals acquired with portable functional near-infrared spectroscopy (fNIRS) system. The system may generate command signals for operating a wearable robotic exoskeleton hand using two-state MWL signals. The fNIRS system is used to record optical signals in the form of change in concentration of oxy and deoxygenated hemoglobin (HbO and HbR) from the pre-frontal cortex (PFC) region of the brain. Fifteen participants participated in this study and were given hand-grasping tasks. Two-state MWL signals acquired from the PFC region of the participant's brain are segregated using machine learning classifier-support vector machines (SVM) to utilize in operating a robotic exoskeleton hand. The maximum classification accuracy is 91.31%, using a combination of mean-slope features with an average information transfer rate (ITR) of 1.43. These results show the feasibility of a two-state MWL (fNIRS-based) robotic exoskeleton hand (BMI system) for hemiplegic patients assisting in the physical grasping tasks.
Collapse
Affiliation(s)
- Umer Asgher
- School of Mechanical and Manufacturing Engineering (SMME), National University of Sciences and Technology (NUST), Islamabad, Pakistan
| | - Muhammad Jawad Khan
- School of Mechanical and Manufacturing Engineering (SMME), National University of Sciences and Technology (NUST), Islamabad, Pakistan
| | - Muhammad Hamza Asif Nizami
- School of Mechanical and Manufacturing Engineering (SMME), National University of Sciences and Technology (NUST), Islamabad, Pakistan
- Florida State University College of Engineering, Florida A&M University, Tallahassee, FL, United States
| | - Khurram Khalil
- School of Mechanical and Manufacturing Engineering (SMME), National University of Sciences and Technology (NUST), Islamabad, Pakistan
| | - Riaz Ahmad
- School of Mechanical and Manufacturing Engineering (SMME), National University of Sciences and Technology (NUST), Islamabad, Pakistan
- Directorate of Quality Assurance and International Collaboration, National University of Sciences and Technology (NUST), Islamabad, Pakistan
| | - Yasar Ayaz
- School of Mechanical and Manufacturing Engineering (SMME), National University of Sciences and Technology (NUST), Islamabad, Pakistan
- National Center of Artificial Intelligence (NCAI), National University of Sciences and Technology, Islamabad, Pakistan
| | - Noman Naseer
- Department of Mechatronics and Biomedical Engineering, Air University, Islamabad, Pakistan
| |
Collapse
|
8
|
Jeong H, Song M, Oh S, Kim J, Kim J. Toward Comparison of Cortical Activation with Different Motor Learning Methods Using Event-Related Design: EEG-fNIRS Study. ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY. IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY. ANNUAL INTERNATIONAL CONFERENCE 2020; 2019:6339-6342. [PMID: 31947292 DOI: 10.1109/embc.2019.8857693] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 11/10/2022]
Abstract
Recently, motor imagery brain-computer interface (MI-BCI) has been studied as a motor learning method and evaluated by comparing with conventional passive and active training. Most functional near-infrared spectroscopy (fNIRS) studies adopted block design for comparing those motor learning methods, including MI-BCI. Compared to the block design, event-related design would be more appropriate for estimating cortical activation in MI-BCI which provides feedback for each trial. This paper is a preliminary study to check the feasibility whether event-related design can be applicable for MI-BCI. To this end, three different motor learning methods involving MI-BCI were compared. In hemodynamic response, MI-BCI showed significantly stronger cortical activation than passive training (PT), and weaker than active training (AT), which conforms most existing studies. The results demonstrate that event-related design could be applied to investigate cortical effects of MI-BCI and comparing hemodynamic responses of different motor learning methods.
Collapse
|
9
|
Mirbagheri M, Hakimi N, Ebrahimzadeh E, Setarehdan SK. Simulation and in vivo investigation of light-emitting diode, near infrared Gaussian beam profiles. JOURNAL OF NEAR INFRARED SPECTROSCOPY 2019. [DOI: 10.1177/0967033519884209] [Citation(s) in RCA: 6] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 02/01/2023]
Abstract
Near infrared spectroscopy is an optical imaging technique which offers a non-invasive, portable, and low-cost method for continuously measuring the oxygenation of tissues. In particular, it can provide the brain activation through measuring the blood oxygenation and blood volume in the cortex. Understanding and then improving the spatial and depth sensitivity of near infrared spectroscopy measurements to brain tissue are essential for designing experiments as well as interpreting research findings. In this study, we investigate the effect of applying two common light beam profiles including Uniform and Gaussian on the penetration depth of an LED-based near infrared spectroscopy. In this regard, two Gaussian profiles were produced by adjusting plano-convex and bi-convex lenses and the Uniform profile was provided by applying a flat lens. Two experiments were conducted in this study. First, a simulation experiment was carried out based on scanning the intra space of a liquid phantom by using static and pulsating absorbers to compare the penetration depth of the configurations applied on the LED-based near infrared spectroscopy with that of a laser-based near infrared spectroscopy. Second, to show the feasibility of the best proposed configuration applied, an in vivo experiment of stress assessment has been performed and its results have been compared with that results obtained by laser one. The results showed that the LED-based near infrared spectroscopy equipped with bi-convex lens provides a penetration depth and hence quality measurements of near infrared spectroscopy and its extracted heart rate variability signals as well as laser-based near infrared spectroscopy especially in the application of stress assessment.
Collapse
Affiliation(s)
- Mahya Mirbagheri
- Control and Intelligent Processing Center of Excellence, School of Electrical and Computer Engineering, College of Engineering, University of Tehran, Tehran, Iran
| | - Naser Hakimi
- Control and Intelligent Processing Center of Excellence, School of Electrical and Computer Engineering, College of Engineering, University of Tehran, Tehran, Iran
| | - Elias Ebrahimzadeh
- Control and Intelligent Processing Center of Excellence, School of Electrical and Computer Engineering, College of Engineering, University of Tehran, Tehran, Iran
- Department of Clinical Neurosciences, University of Calgary, Calgary, Alberta, Canada
- Hotchkiss Brain Institute, Cumming School of Medicine, University of Calgary, Calgary, Alberta, Canada
- Seaman Family MR Research Centre, University of Calgary, Calgary, Alberta, Canada
| | - S Kamaledin Setarehdan
- Control and Intelligent Processing Center of Excellence, School of Electrical and Computer Engineering, College of Engineering, University of Tehran, Tehran, Iran
| |
Collapse
|
10
|
Kim J, Oh S, Kim J, Kim J. A two-wire body weight support system for interactive treadmill. IEEE Int Conf Rehabil Robot 2019; 2019:349-354. [PMID: 31374654 DOI: 10.1109/icorr.2019.8779549] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/05/2022]
Abstract
Body weight support (BWS) system is widely used for patients to help their gait training. However, that existing systems require large workspace and elastic component in actuation makes the systems inappropriate for wide clinical use. The interactive treadmill was reported to be cost/space effectively simulate overground walking, but there was no suitable BWS system for the treadmill. We proposed a new concept of body weight support system for interactive treadmill. For wide clinical use, we applied a two-wire driven mechanism with simple actuator and a custom pelvic-type harness. With three healthy subjects, the performance of the proposed BWS system on unloading force control was evaluated, and the result showed that the feasibility of the proposed BWS system.
Collapse
|