Traub-Weidinger T, Arbizu J, Barthel H, Boellaard R, Borgwardt L, Brendel M, Cecchin D, Chassoux F, Fraioli F, Garibotto V, Guedj E, Hammers A, Law I, Morbelli S, Tolboom N, Van Weehaeghe D, Verger A, Van Paesschen W, von Oertzen TJ, Zucchetta P, Semah F. EANM practice guidelines for an appropriate use of PET and SPECT for patients with epilepsy. Eur J Nucl Med Mol Imaging 2024; 51:1891-1908. [PMID: 38393374 PMCID: PMC11139752 DOI: 10.1007/s00259-024-06656-3] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/01/2023] [Accepted: 02/13/2024] [Indexed: 02/25/2024]
Abstract
Epilepsy is one of the most frequent neurological conditions with an estimated prevalence of more than 50 million people worldwide and an annual incidence of two million. Although pharmacotherapy with anti-seizure medication (ASM) is the treatment of choice, ~30% of patients with epilepsy do not respond to ASM and become drug resistant. Focal epilepsy is the most frequent form of epilepsy. In patients with drug-resistant focal epilepsy, epilepsy surgery is a treatment option depending on the localisation of the seizure focus for seizure relief or seizure freedom with consecutive improvement in quality of life. Beside examinations such as scalp video/electroencephalography (EEG) telemetry, structural, and functional magnetic resonance imaging (MRI), which are primary standard tools for the diagnostic work-up and therapy management of epilepsy patients, molecular neuroimaging using different radiopharmaceuticals with single-photon emission computed tomography (SPECT) and positron emission tomography (PET) influences and impacts on therapy decisions. To date, there are no literature-based praxis recommendations for the use of Nuclear Medicine (NM) imaging procedures in epilepsy. The aims of these guidelines are to assist in understanding the role and challenges of radiotracer imaging for epilepsy; to provide practical information for performing different molecular imaging procedures for epilepsy; and to provide an algorithm for selecting the most appropriate imaging procedures in specific clinical situations based on current literature. These guidelines are written and authorized by the European Association of Nuclear Medicine (EANM) to promote optimal epilepsy imaging, especially in the presurgical setting in children, adolescents, and adults with focal epilepsy. They will assist NM healthcare professionals and also specialists such as Neurologists, Neurophysiologists, Neurosurgeons, Psychiatrists, Psychologists, and others involved in epilepsy management in the detection and interpretation of epileptic seizure onset zone (SOZ) for further treatment decision. The information provided should be applied according to local laws and regulations as well as the availability of various radiopharmaceuticals and imaging modalities.
Collapse
Affiliation(s)
- Tatjana Traub-Weidinger
- Division of Nuclear Medicine, Department of Biomedical Imaging and Image-guided Therapy, Medical University of Vienna, Vienna, Austria
| | - Javier Arbizu
- Department of Nuclear Medicine, University of Navarra Clinic, Pamplona, Spain
| | - Henryk Barthel
- Department of Nuclear Medicine, Leipzig University Medical Centre, Leipzig, Germany
| | - Ronald Boellaard
- Department of Radiology and Nuclear Medicine, Amsterdam UMC, Location VUmc, Amsterdam, The Netherlands
| | - Lise Borgwardt
- Department of Clinical Physiology and Nuclear Medicine, University of Copenhagen, Blegdamsvej 9, DK-2100, RigshospitaletCopenhagen, Denmark
| | - Matthias Brendel
- Department of Nuclear Medicine, Ludwig Maximilian-University of Munich, Munich, Germany
- DZNE-German Center for Neurodegenerative Diseases, Munich, Germany
- Munich Cluster for Systems Neurology (SyNergy), Munich, Germany
| | - Diego Cecchin
- Nuclear Medicine Unit, Department of Medicine-DIMED, University-Hospital of Padova, Padova, Italy
| | - Francine Chassoux
- Université Paris-Saclay, CEA, CNRS, Inserm, BioMaps, 91401, Orsay, France
| | - Francesco Fraioli
- Institute of Nuclear Medicine, University College London (UCL), London, UK
| | - Valentina Garibotto
- Division of Nuclear Medicine and Molecular Imaging, Geneva University Hospitals, Geneva, Switzerland
- NIMTLab, Faculty of Medicine, University of Geneva, Geneva, Switzerland
- Center for Biomedical Imaging (CIBM), Geneva, Switzerland
| | - Eric Guedj
- APHM, CNRS, Centrale Marseille, Institut Fresnel, Timone Hospital, CERIMED, Nuclear Medicine Department, Aix Marseille Univ, Marseille, France
| | - Alexander Hammers
- School of Biomedical Engineering and Imaging Sciences, Faculty of Life Sciences and Medicine, King's College London & Guy's and St Thomas' PET Centre, King's College London, London, UK
| | - Ian Law
- Department of Clinical Physiology and Nuclear Medicine, Rigshospitalet, University of Copenhagen, Blegdamsvej 9, DK-2100, Copenhagen, Denmark
| | - Silvia Morbelli
- Nuclear Medicine Unit, IRCCS Ospedale Policlinico San Martino, Department of Health Sciences (DISSAL), University of Genoa, Genoa, Italy
| | - Nelleke Tolboom
- Department of Radiology and Nuclear Medicine, University Medical Center Utrecht, Utrecht University, Utrecht, The Netherlands
| | | | - Antoine Verger
- Department of Nuclear Medicine and Nancyclotep Imaging Platform, CHRU Nancy, Université de Lorraine, IADI, INSERM U1254, Nancy, France
| | - Wim Van Paesschen
- Laboratory for Epilepsy Research, KU Leuven and Department of Neurology, University Hospitals, Leuven, Belgium
| | - Tim J von Oertzen
- Depts of Neurology 1&2, Kepler University Hospital, Johannes Kepler University, Linz, Austria
| | - Pietro Zucchetta
- Nuclear Medicine Unit, Department of Medicine-DIMED, University-Hospital of Padova, Padova, Italy
| | - Franck Semah
- Nuclear Medicine Department, University Hospital, Inserm, CHU Lille, U1172-LilNCog-Lille, F-59000, Lille, France.
| |
Collapse
|
2
|
Naghavi-Behzad M, Vogsen M, Gerke O, Dahlsgaard-Wallenius SE, Nissen HJ, Jakobsen NM, Braad PE, Vilstrup MH, Deak P, Hildebrandt MG, Andersen TL. Comparison of Image Quality and Quantification Parameters between Q.Clear and OSEM Reconstruction Methods on FDG-PET/CT Images in Patients with Metastatic Breast Cancer. J Imaging 2023; 9:jimaging9030065. [PMID: 36976116 PMCID: PMC10058454 DOI: 10.3390/jimaging9030065] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/23/2023] [Revised: 03/01/2023] [Accepted: 03/07/2023] [Indexed: 03/11/2023] Open
Abstract
We compared the image quality and quantification parameters through bayesian penalized likelihood reconstruction algorithm (Q.Clear) and ordered subset expectation maximization (OSEM) algorithm for 2-[18F]FDG-PET/CT scans performed for response monitoring in patients with metastatic breast cancer in prospective setting. We included 37 metastatic breast cancer patients diagnosed and monitored with 2-[18F]FDG-PET/CT at Odense University Hospital (Denmark). A total of 100 scans were analyzed blinded toward Q.Clear and OSEM reconstruction algorithms regarding image quality parameters (noise, sharpness, contrast, diagnostic confidence, artefacts, and blotchy appearance) using a five-point scale. The hottest lesion was selected in scans with measurable disease, considering the same volume of interest in both reconstruction methods. SULpeak (g/mL) and SUVmax (g/mL) were compared for the same hottest lesion. There was no significant difference regarding noise, diagnostic confidence, and artefacts within reconstruction methods; Q.Clear had significantly better sharpness (p < 0.001) and contrast (p = 0.001) than the OSEM reconstruction, while the OSEM reconstruction had significantly less blotchy appearance compared with Q.Clear reconstruction (p < 0.001). Quantitative analysis on 75/100 scans indicated that Q.Clear reconstruction had significantly higher SULpeak (5.33 ± 2.8 vs. 4.85 ± 2.5, p < 0.001) and SUVmax (8.27 ± 4.8 vs. 6.90 ± 3.8, p < 0.001) compared with OSEM reconstruction. In conclusion, Q.Clear reconstruction revealed better sharpness, better contrast, higher SUVmax, and higher SULpeak, while OSEM reconstruction had less blotchy appearance.
Collapse
Affiliation(s)
- Mohammad Naghavi-Behzad
- Department of Clinical Research, University of Southern Denmark, 5000 Odense, Denmark (T.L.A.)
- Department of Nuclear Medicine, Odense University Hospital, 5000 Odense, Denmark
- Centre for Personalized Response Monitoring in Oncology, Odense University Hospital, 5000 Odense, Denmark
- Correspondence: ; Tel.: +45-9160-9622
| | - Marianne Vogsen
- Department of Clinical Research, University of Southern Denmark, 5000 Odense, Denmark (T.L.A.)
- Department of Nuclear Medicine, Odense University Hospital, 5000 Odense, Denmark
- Centre for Personalized Response Monitoring in Oncology, Odense University Hospital, 5000 Odense, Denmark
- Department of Oncology, Odense University Hospital, 5000 Odense, Denmark
| | - Oke Gerke
- Department of Clinical Research, University of Southern Denmark, 5000 Odense, Denmark (T.L.A.)
- Department of Nuclear Medicine, Odense University Hospital, 5000 Odense, Denmark
| | - Sara Elisabeth Dahlsgaard-Wallenius
- Department of Clinical Research, University of Southern Denmark, 5000 Odense, Denmark (T.L.A.)
- Department of Nuclear Medicine, Odense University Hospital, 5000 Odense, Denmark
| | - Henriette Juel Nissen
- Department of Clinical Research, University of Southern Denmark, 5000 Odense, Denmark (T.L.A.)
- Department of Nuclear Medicine, Odense University Hospital, 5000 Odense, Denmark
| | - Nick Møldrup Jakobsen
- Department of Clinical Research, University of Southern Denmark, 5000 Odense, Denmark (T.L.A.)
- Department of Nuclear Medicine, Odense University Hospital, 5000 Odense, Denmark
| | - Poul-Erik Braad
- Department of Clinical Research, University of Southern Denmark, 5000 Odense, Denmark (T.L.A.)
- Department at Clinical Engineering, Region of Southern Denmark, 6200 Aabenraa, Denmark
| | - Mie Holm Vilstrup
- Department of Clinical Research, University of Southern Denmark, 5000 Odense, Denmark (T.L.A.)
- Department of Nuclear Medicine, Odense University Hospital, 5000 Odense, Denmark
| | - Paul Deak
- Healthcare Science Technology, GE Healthcare, Chicago, IL 06828, USA
| | - Malene Grubbe Hildebrandt
- Department of Clinical Research, University of Southern Denmark, 5000 Odense, Denmark (T.L.A.)
- Department of Nuclear Medicine, Odense University Hospital, 5000 Odense, Denmark
- Centre for Personalized Response Monitoring in Oncology, Odense University Hospital, 5000 Odense, Denmark
- Centre for Innovative Medical Technology, Odense University Hospital, 5000 Odense, Denmark
| | - Thomas Lund Andersen
- Department of Clinical Research, University of Southern Denmark, 5000 Odense, Denmark (T.L.A.)
- Department of Clinical Physiology and Nuclear Medicine, Rigshospitalet, 2100 Copenhagen, Denmark
| |
Collapse
|
3
|
Magota K, Shinyama D. [[PET] 1. Characteristics and Clinical Applications of SiPM-based PET System]. Nihon Hoshasen Gijutsu Gakkai Zasshi 2022; 78:1488-1494. [PMID: 36543233 DOI: 10.6009/jjrt.2022-2129] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/23/2022]
Affiliation(s)
- Keiichi Magota
- Division of Medical Imaging and Technology, Hokkaido University Hospital
| | | |
Collapse
|
4
|
Ahrari S, Zaragori T, Bros M, Oster J, Imbert L, Verger A. Implementing the Point Spread Function Deconvolution for Better Molecular Characterization of Newly Diagnosed Gliomas: A Dynamic 18F-FDOPA PET Radiomics Study. Cancers (Basel) 2022; 14:cancers14235765. [PMID: 36497245 PMCID: PMC9738921 DOI: 10.3390/cancers14235765] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/18/2022] [Revised: 11/10/2022] [Accepted: 11/17/2022] [Indexed: 11/25/2022] Open
Abstract
Purpose: This study aims to investigate the effects of applying the point spread function deconvolution (PSFd) to the radiomics analysis of dynamic L-3,4-dihydroxy-6-[18F]-fluoro-phenyl-alanine (18F-FDOPA) positron emission tomography (PET) images, to non-invasively identify isocitrate dehydrogenase (IDH) mutated and/or 1p/19q codeleted gliomas. Methods: Fifty-seven newly diagnosed glioma patients underwent dynamic 18F-FDOPA imaging on the same digital PET system. All images were reconstructed with and without PSFd. An L1-penalized (Lasso) logistic regression model, with 5-fold cross-validation and 20 repetitions, was trained with radiomics features extracted from the static tumor-to-background-ratio (TBR) and dynamic time-to-peak (TTP) parametric images, as well as a combination of both. Feature importance was assessed using Shapley additive explanation values. Results: The PSFd significantly modified 95% of TBR, but only 79% of TTP radiomics features. Applying the PSFd significantly improved the ability to identify IDH-mutated and/or 1p/19q codeleted gliomas, compared to PET images not processed with PSFd, with respective areas under the curve of 0.83 versus 0.79 and 0.75 versus 0.68 for a combination of static and dynamic radiomics features (p < 0.001). Without the PSFd, four and eight radiomics features contributed to 50% of the model for detecting IDH-mutated and/or 1p/19q codeleted gliomas, respectively. Application of the PSFd reduced this to three and seven contributive radiomics features. Conclusion: Application of the PSFd to dynamic 18F-FDOPA PET imaging significantly improves the detection of molecular parameters in newly diagnosed gliomas, most notably by modifying TBR radiomics features.
Collapse
Affiliation(s)
- Shamimeh Ahrari
- Imagerie Adaptative Diagnostique et Interventionnelle, Institut National de la Santé et de la Recherche Médicale U1254, Université de Lorraine, F-54000 Nancy, France
- Nancyclotep Imaging Platform, Université de Lorraine, F-54000 Nancy, France
| | - Timothée Zaragori
- Imagerie Adaptative Diagnostique et Interventionnelle, Institut National de la Santé et de la Recherche Médicale U1254, Université de Lorraine, F-54000 Nancy, France
- Nancyclotep Imaging Platform, Université de Lorraine, F-54000 Nancy, France
| | - Marie Bros
- Department of Nuclear Medicine, Centre Hospitalier Régional Universitaire de Nancy, F-54000 Nancy, France
| | - Julien Oster
- Imagerie Adaptative Diagnostique et Interventionnelle, Institut National de la Santé et de la Recherche Médicale U1254, Université de Lorraine, F-54000 Nancy, France
| | - Laetitia Imbert
- Imagerie Adaptative Diagnostique et Interventionnelle, Institut National de la Santé et de la Recherche Médicale U1254, Université de Lorraine, F-54000 Nancy, France
- Nancyclotep Imaging Platform, Université de Lorraine, F-54000 Nancy, France
- Department of Nuclear Medicine, Centre Hospitalier Régional Universitaire de Nancy, F-54000 Nancy, France
| | - Antoine Verger
- Imagerie Adaptative Diagnostique et Interventionnelle, Institut National de la Santé et de la Recherche Médicale U1254, Université de Lorraine, F-54000 Nancy, France
- Nancyclotep Imaging Platform, Université de Lorraine, F-54000 Nancy, France
- Department of Nuclear Medicine, Centre Hospitalier Régional Universitaire de Nancy, F-54000 Nancy, France
- Correspondence:
| |
Collapse
|
5
|
Hildebrandt MG, Naghavi-Behzad M, Vogsen M. A role of FDG-PET/CT for response evaluation in metastatic breast cancer? Semin Nucl Med 2022; 52:520-530. [PMID: 35525631 DOI: 10.1053/j.semnuclmed.2022.03.004] [Citation(s) in RCA: 2] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/14/2022] [Accepted: 03/27/2022] [Indexed: 01/19/2023]
Abstract
Breast cancer prognosis is steadily improving due to early detection of primary cancer in screening programs and revolutionizing treatment development. In the metastatic setting, therapy improvements render breast cancer a chronic disease. Although FDG-PET/CT has emerged as a highly accurate method for staging metastatic breast cancer, there has been no change in response evaluation methods for decades. FDG-PET/CT has proven high prognostic values in patients with metastatic breast cancer when using quantitative PET methods. It has also shown a higher predictive value than conventional CT when applying the respective response evaluation criteria, RECIST and PERCIST. Response categorization using FDG-PET/CT is more sensitive in detecting progressive and regressive disease, while conventional imaging such as CT and bone scintigraphy deem stable disease more often. These findings reflect the higher accuracy of FDG-PET/CT for response evaluation in this patient group. But does the higher accuracy of FDG-PET/CT translate into a patient benefit when implementing it for monitoring response to palliative treatment? We have evidence of survival benefit from a retrospective study indicating the superiority of using FDG-PET/CT compared with conventional imaging for response evaluation in metastatic breast cancer patients. The survival benefit seems to result from earlier detection of progression with FDG-PET/CT than conventional imaging, leading to an earlier change in treatment with potentially better efficacy of the subsequent treatment line. FDG-PET/CT can be used semiquantitatively as suggested in PERCIST. However, we still need to improve clinically applicable methods based on neural network modeling to better integrate the quantitative information in a smart and standardized way, enabling relevant comparability between scans, patients, and institutions. Such innovation is warranted to support imaging specialists in diagnostic response assessment. Prospective multicenter studies analyzing patients' survival, quality of life, societal and patient costs of replacing conventional imaging with FDG-PET/CT are needed before firm conclusions can be drawn on which type of scan to recommend in future clinical guidelines.
Collapse
Affiliation(s)
- Malene Grubbe Hildebrandt
- Department of Nuclear Medicine, Odense University Hospital, Odense, Denmark; Department of Clinical Research, University of Southern Denmark, Odense, Denmark; Center for Personalized Response Monitoring in Oncology, PREMIO, Odense University Hospital, Odense, Denmark; Center for Innovative Medical Technology, CIMT, Odense University Hospital, Odense, Denmark.
| | - Mohammad Naghavi-Behzad
- Department of Nuclear Medicine, Odense University Hospital, Odense, Denmark; Department of Clinical Research, University of Southern Denmark, Odense, Denmark; Center for Personalized Response Monitoring in Oncology, PREMIO, Odense University Hospital, Odense, Denmark
| | - Marianne Vogsen
- Department of Nuclear Medicine, Odense University Hospital, Odense, Denmark; Department of Clinical Research, University of Southern Denmark, Odense, Denmark; Center for Personalized Response Monitoring in Oncology, PREMIO, Odense University Hospital, Odense, Denmark; Department of Oncology, Odense University Hospital, Odense, Denmark
| |
Collapse
|
6
|
PET Imaging in Neuro-Oncology: An Update and Overview of a Rapidly Growing Area. Cancers (Basel) 2022; 14:cancers14051103. [PMID: 35267411 PMCID: PMC8909369 DOI: 10.3390/cancers14051103] [Citation(s) in RCA: 18] [Impact Index Per Article: 9.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/17/2022] [Revised: 02/08/2022] [Accepted: 02/19/2022] [Indexed: 12/21/2022] Open
Abstract
Simple Summary Positron emission tomography (PET) is a functional imaging technique which plays an increasingly important role in the management of brain tumors. Owing different radiotracers, PET allows to image different metabolic aspects of the brain tumors. This review outlines currently available PET radiotracers and their respective indications in neuro-oncology. It specifically focuses on the investigation of gliomas, meningiomas, primary central nervous system lymphomas as well as brain metastases. Recent advances in the production of PET radiotracers, image analyses and translational applications to peptide radionuclide receptor therapy, which allow to treat brain tumors with radiotracers, are also discussed. The objective of this review is to provide a comprehensive overview of PET imaging’s potential in neuro-oncology as an adjunct to brain magnetic resonance imaging (MRI). Abstract PET plays an increasingly important role in the management of brain tumors. This review outlines currently available PET radiotracers and their respective indications. It specifically focuses on 18F-FDG, amino acid and somatostatin receptor radiotracers, for imaging gliomas, meningiomas, primary central nervous system lymphomas as well as brain metastases. Recent advances in radiopharmaceuticals, image analyses and translational applications to therapy are also discussed. The objective of this review is to provide a comprehensive overview of PET imaging’s potential in neuro-oncology as an adjunct to brain MRI for all medical professionals implicated in brain tumor diagnosis and care.
Collapse
|
7
|
Rogasch JMM, Hofheinz F, van Heek L, Voltin CA, Boellaard R, Kobe C. Influences on PET Quantification and Interpretation. Diagnostics (Basel) 2022; 12:diagnostics12020451. [PMID: 35204542 PMCID: PMC8871060 DOI: 10.3390/diagnostics12020451] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/09/2021] [Revised: 01/06/2022] [Accepted: 02/08/2022] [Indexed: 01/21/2023] Open
Abstract
Various factors have been identified that influence quantitative accuracy and image interpretation in positron emission tomography (PET). Through the continuous introduction of new PET technology—both imaging hardware and reconstruction software—into clinical care, we now find ourselves in a transition period in which traditional and new technologies coexist. The effects on the clinical value of PET imaging and its interpretation in routine clinical practice require careful reevaluation. In this review, we provide a comprehensive summary of important factors influencing quantification and interpretation with a focus on recent developments in PET technology. Finally, we discuss the relationship between quantitative accuracy and subjective image interpretation.
Collapse
Affiliation(s)
- Julian M. M. Rogasch
- Department of Nuclear Medicine, Charité—Universitätsmedizin Berlin, Corporate Member of Freie Universität Berlin and Humboldt-Universität zu Berlin, 13353 Berlin, Germany;
- Berlin Institute of Health at Charité, Universitätsmedizin Berlin, 10178 Berlin, Germany
| | - Frank Hofheinz
- Institute of Radiopharmaceutical Cancer Research, Helmholtz Center Dresden-Rossendorf, 01328 Dresden, Germany;
| | - Lutz van Heek
- Department of Nuclear Medicine, Faculty of Medicine and University Hospital Cologne, University of Cologne, 50937 Cologne, Germany; (L.v.H.); (C.-A.V.)
| | - Conrad-Amadeus Voltin
- Department of Nuclear Medicine, Faculty of Medicine and University Hospital Cologne, University of Cologne, 50937 Cologne, Germany; (L.v.H.); (C.-A.V.)
| | - Ronald Boellaard
- Department of Radiology and Nuclear Medicine, Cancer Center Amsterdam (CCA), Amsterdam University Medical Center, Free University Amsterdam, 1081 HV Amsterdam, The Netherlands;
| | - Carsten Kobe
- Department of Nuclear Medicine, Faculty of Medicine and University Hospital Cologne, University of Cologne, 50937 Cologne, Germany; (L.v.H.); (C.-A.V.)
- Correspondence: ; Tel.: +49-221-478-7534
| |
Collapse
|
8
|
Guedj E, Varrone A, Boellaard R, Albert NL, Barthel H, van Berckel B, Brendel M, Cecchin D, Ekmekcioglu O, Garibotto V, Lammertsma AA, Law I, Peñuelas I, Semah F, Traub-Weidinger T, van de Giessen E, Van Weehaeghe D, Morbelli S. EANM procedure guidelines for brain PET imaging using [ 18F]FDG, version 3. Eur J Nucl Med Mol Imaging 2021; 49:632-651. [PMID: 34882261 PMCID: PMC8803744 DOI: 10.1007/s00259-021-05603-w] [Citation(s) in RCA: 76] [Impact Index Per Article: 25.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/10/2021] [Accepted: 10/21/2021] [Indexed: 12/13/2022]
Abstract
The present procedural guidelines summarize the current views of the EANM Neuro-Imaging Committee (NIC). The purpose of these guidelines is to assist nuclear medicine practitioners in making recommendations, performing, interpreting, and reporting results of [18F]FDG-PET imaging of the brain. The aim is to help achieve a high-quality standard of [18F]FDG brain imaging and to further increase the diagnostic impact of this technique in neurological, neurosurgical, and psychiatric practice. The present document replaces a former version of the guidelines that have been published in 2009. These new guidelines include an update in the light of advances in PET technology such as the introduction of digital PET and hybrid PET/MR systems, advances in individual PET semiquantitative analysis, and current broadening clinical indications (e.g., for encephalitis and brain lymphoma). Further insight has also become available about hyperglycemia effects in patients who undergo brain [18F]FDG-PET. Accordingly, the patient preparation procedure has been updated. Finally, most typical brain patterns of metabolic changes are summarized for neurodegenerative diseases. The present guidelines are specifically intended to present information related to the European practice. The information provided should be taken in the context of local conditions and regulations.
Collapse
Affiliation(s)
- Eric Guedj
- APHM, CNRS, Centrale Marseille, Institut Fresnel, Timone Hospital, CERIMED, Nuclear Medicine Department, Aix Marseille Univ, Marseille, France. .,Service Central de Biophysique et Médecine Nucléaire, Hôpital de la Timone, 264 rue Saint Pierre, 13005, Marseille, France.
| | - Andrea Varrone
- Department of Clinical Neuroscience, Centre for Psychiatry Research, Karolinska Institutet and Stockholm Healthcare Services, Stockholm, Sweden
| | - Ronald Boellaard
- Department of Radiology and Nuclear Medicine, Amsterdam UMC, Location VUmc, Amsterdam, The Netherlands.,Nuclear Medicine and Molecular Imaging, University Medical Center Groningen, University of Groningen, Groningen, The Netherlands
| | - Nathalie L Albert
- Department of Nuclear Medicine, Ludwig Maximilians-University of Munich, Munich, Germany
| | - Henryk Barthel
- Department of Nuclear Medicine, Leipzig University, Leipzig, Germany
| | - Bart van Berckel
- Department of Radiology and Nuclear Medicine, Amsterdam UMC, Location VUmc, Amsterdam, The Netherlands
| | - Matthias Brendel
- Department of Nuclear Medicine, Ludwig Maximilians-University of Munich, Munich, Germany.,German Centre of Neurodegenerative Diseases (DZNE), Site Munich, Bonn, Germany
| | - Diego Cecchin
- Nuclear Medicine Unit, Department of Medicine - DIMED, University of Padua, Padua, Italy
| | - Ozgul Ekmekcioglu
- Sisli Hamidiye Etfal Education and Research Hospital, Nuclear Medicine Dept., University of Health Sciences, Istanbul, Turkey
| | - Valentina Garibotto
- NIMTLab, Faculty of Medicine, Geneva University, Geneva, Switzerland.,Division of Nuclear Medicine and Molecular Imaging, Geneva University Hospitals, Geneva, Switzerland
| | - Adriaan A Lammertsma
- Department of Radiology and Nuclear Medicine, Amsterdam UMC, Location VUmc, Amsterdam, The Netherlands.,Nuclear Medicine and Molecular Imaging, University Medical Center Groningen, University of Groningen, Groningen, The Netherlands
| | - Ian Law
- Department of Clinical Physiology, Nuclear Medicine and PET, Rigshospitalet, University of Copenhagen, Copenhagen, Denmark
| | - Iván Peñuelas
- Department of Nuclear Medicine, Clinica Universidad de Navarra, IdiSNA, University of Navarra, Pamplona, Spain
| | - Franck Semah
- Nuclear Medicine Department, University Hospital, Lille, France
| | - Tatjana Traub-Weidinger
- Division of Nuclear Medicine, Department of Biomedical Imaging and Image-guided Therapy, Medical University of Vienna, Vienna, Austria
| | - Elsmarieke van de Giessen
- Department of Radiology and Nuclear Medicine, Amsterdam UMC, Location VUmc, Amsterdam, The Netherlands.,Radiology and Nuclear Medicine, Amsterdam UMC, Location AMC, Meibergdreef 9, Amsterdam, The Netherlands
| | | | - Silvia Morbelli
- IRCCS Ospedale Policlinico San Martino, Genoa, Italy.,Nuclear Medicine Unit, Department of Health Sciences (DISSAL), University of Genoa, Genoa, Italy
| |
Collapse
|
9
|
López-Mora DA, Carrió I, Flotats A. Digital PET vs Analog PET: Clinical Implications? Semin Nucl Med 2021; 52:302-311. [PMID: 34836617 DOI: 10.1053/j.semnuclmed.2021.10.004] [Citation(s) in RCA: 11] [Impact Index Per Article: 3.7] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/12/2021] [Accepted: 10/19/2021] [Indexed: 12/17/2022]
Abstract
Positron emission tomography (PET) is a functional imaging technique introduced in 1970s. Over the years, PET was used alone but is in 2000 when the first hybrid PET/CT device was clinically introduced. Since then, PET has continuously been marked by technological developments, being the most recent one the introduction of silicon photomultipliers (SiPMs) as an alternative to standard photomultiplier tubes used in analog PET/CT systems. SiPMs, the basis for the so called digital PET/CT systems, are smaller than standard photomultiplier tubes (enabling higher spatial resolution) and provide up to 100% coverage of the crystal area, as well as high sensitivity, low noise, and fast timing resolution. SiPMs in combination with optimized acquisition and reconstruction parameters improve the localization of the annihilation events, provide high definition PET images, and offer higher sensitivity and higher diagnostic performance. This article summarizes the evidence about the superior performance of the state of the art digital PET and highlights its potential clinical implications. Digital PET opens new perspectives in the quantification and characterization of small lesions, which are mostly undetectable using analog PET systems, potentially changing patient management and improving outcomes in oncological and non-oncological diseases. Moreover, digital PET offers the possibility to reduce radiation dose and scan times which may facilitate the implementation of PET to address unmet clinical needs.
Collapse
Affiliation(s)
- Diego Alfonso López-Mora
- Nuclear Medicine Department, Hospital de la Santa Creu i Sant Pau, Universitat Autònoma de Barcelona, Barcelona, Spain.
| | - Ignasi Carrió
- Nuclear Medicine Department, Hospital de la Santa Creu i Sant Pau, Universitat Autònoma de Barcelona, Barcelona, Spain
| | - Albert Flotats
- Nuclear Medicine Department, Hospital de la Santa Creu i Sant Pau, Universitat Autònoma de Barcelona, Barcelona, Spain
| |
Collapse
|
10
|
Zaragori T, Doyen M, Rech F, Blonski M, Taillandier L, Imbert L, Verger A. Dynamic 18F-FDopa PET Imaging for Newly Diagnosed Gliomas: Is a Semiquantitative Model Sufficient? Front Oncol 2021; 11:735257. [PMID: 34676168 PMCID: PMC8523996 DOI: 10.3389/fonc.2021.735257] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/02/2021] [Accepted: 09/06/2021] [Indexed: 11/13/2022] Open
Abstract
Purpose Dynamic amino acid positron emission tomography (PET) has become essential in neuro-oncology, most notably for its prognostic value in the noninvasive prediction of isocitrate dehydrogenase (IDH) mutations in newly diagnosed gliomas. The 6-[18F]fluoro-l-DOPA (18F-FDOPA) kinetic model has an underlying complexity, while previous studies have predominantly used a semiquantitative dynamic analysis. Our study addresses whether a semiquantitative analysis can capture all the relevant information contained in time–activity curves for predicting the presence of IDH mutations compared to the more sophisticated graphical and compartmental models. Methods Thirty-seven tumour time–activity curves from 18F-FDOPA PET dynamic acquisitions of newly diagnosed gliomas (median age = 58.3 years, range = 20.3–79.9 years, 16 women, 16 IDH-wild type) were analyzed with a semiquantitative model based on classical parameters, with (SQ) or without (Ref SQ) a reference region, or on parameters of a fit function (SQ Fit), a graphical Logan model with input function (Logan) or reference region (Ref Logan), and a two-tissue compartmental model previously reported for 18F-FDOPA PET imaging of gliomas (2TCM). The overall predictive performance of each model was assessed with an area under the curve (AUC) comparison using multivariate analysis of all the parameters included in the model. Moreover, each extracted parameter was assessed in a univariate analysis by a receiver operating characteristic curve analysis. Results The SQ model with an AUC of 0.733 for predicting IDH mutations showed comparable performance to the other models with AUCs of 0.752, 0.814, 0.693, 0.786, and 0.863, respectively corresponding to SQ Fit, Ref SQ, Logan, Ref Logan, and 2TCM (p ≥ 0.10 for the pairwise comparisons with other models). In the univariate analysis, the SQ time-to-peak parameter had the best diagnostic performance (75.7% accuracy) compared to all other individual parameters considered. Conclusions The SQ model circumvents the complexities of the 18F-FDOPA kinetic model and yields similar performance in predicting IDH mutations when compared to the other models, most notably the compartmental model. Our study provides supportive evidence for the routine clinical application of the SQ model for the dynamic analysis of 18F-FDOPA PET images in newly diagnosed gliomas.
Collapse
Affiliation(s)
- Timothée Zaragori
- Department of Nuclear Medicine and Nancyclotep Imaging Platform, CHRU-Nancy, Université de Lorraine, Nancy, France.,IADI UMR 1254, INSERM, Université de Lorraine, Nancy, France
| | - Matthieu Doyen
- Department of Nuclear Medicine and Nancyclotep Imaging Platform, CHRU-Nancy, Université de Lorraine, Nancy, France.,IADI UMR 1254, INSERM, Université de Lorraine, Nancy, France
| | - Fabien Rech
- Department of Neurosurgery, CHRU-Nancy, Université de Lorraine, Nancy, France.,Centre de Recherche en Automatique de Nancy CRAN UMR 7039, CNRS, Université de Lorraine, Nancy, France
| | - Marie Blonski
- Centre de Recherche en Automatique de Nancy CRAN UMR 7039, CNRS, Université de Lorraine, Nancy, France.,Department of Neuro-Oncology, CHRU-Nancy, Université de Lorraine, Nancy, France
| | - Luc Taillandier
- Centre de Recherche en Automatique de Nancy CRAN UMR 7039, CNRS, Université de Lorraine, Nancy, France.,Department of Neuro-Oncology, CHRU-Nancy, Université de Lorraine, Nancy, France
| | - Laëtitia Imbert
- Department of Nuclear Medicine and Nancyclotep Imaging Platform, CHRU-Nancy, Université de Lorraine, Nancy, France.,IADI UMR 1254, INSERM, Université de Lorraine, Nancy, France
| | - Antoine Verger
- Department of Nuclear Medicine and Nancyclotep Imaging Platform, CHRU-Nancy, Université de Lorraine, Nancy, France.,IADI UMR 1254, INSERM, Université de Lorraine, Nancy, France
| |
Collapse
|
11
|
Verger A, Grimaldi S, Ribeiro MJ, Frismand S, Guedj E. Single Photon Emission Computed Tomography/Positron Emission Tomography Molecular Imaging for Parkinsonism: A Fast-Developing Field. Ann Neurol 2021; 90:711-719. [PMID: 34338333 PMCID: PMC9291534 DOI: 10.1002/ana.26187] [Citation(s) in RCA: 18] [Impact Index Per Article: 6.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/28/2021] [Revised: 07/30/2021] [Accepted: 07/31/2021] [Indexed: 11/26/2022]
Abstract
The early differential diagnosis of Parkinson disease and atypical parkinsonism is a major challenge. The use of single photon emission computed tomography (SPECT)/positron emission tomography (PET) molecular imaging to investigate parkinsonism is a fast‐developing field. Imaging biomarker research may potentially lead to more accurate disease detection, enabling earlier diagnosis and treatment. This review summarizes recent SPECT/PET advances in radiopharmaceuticals and imaging technologies/analyses that improve the diagnosis of neurodegenerative parkinsonism. We are currently witnessing a turning point in the field. Integrating molecular imaging as a diagnostic technique represents an opportunity to reassess the strategies for diagnosing neurodegenerative parkinsonism. ANN NEUROL 2021;90:711–719
Collapse
Affiliation(s)
- Antoine Verger
- Department of Nuclear Medicine & Nancyclotep Imaging Platform, Centre Hospitalier Régional Universitaire Nancy, Lorraine University, Nancy, France.,Imagerie Adaptative Diagnostique et Interventionnelle, Institut National de la Santé et de la Recherche Médicale, Unité Mixte de Recherche 1254, Lorraine University, Nancy, France
| | - Stephan Grimaldi
- Department of Neurology and Movement Disorders, Public Assistance Hospitals of Marseille, Timone University Hospital, Marseille, France
| | - Maria-Joao Ribeiro
- Unité Mixte de Recherche 1253, iBrain, University of Tours, Institut National de la Santé et de la Recherche Médicale Centre d'Investigation Clinique 1415, Centre Hospitalier Régional Universitaire Tours, Tours, France
| | - Solène Frismand
- Department of Neurology, Centre Hospitalier Régional Universitaire Nancy, Lorraine University, Nancy, France
| | - Eric Guedj
- Aix-Marseille University, Centre National de Recherche Scientifique, Central School of Marseille, Unité Mixte de Recherche 7249, Fresnel Institute, Marseille, France.,Department of Nuclear Medicine, Public Assistance Hospitals of Marseille, Timone University Hospital, Marseille, France.,Centre Européen de Recherche en Imagerie Médicale, Aix-Marseille University, Marseille, France
| |
Collapse
|
12
|
Mikami S, Nakamura F, Nakamura A, Torizuka T. [Influence of Reconstruction FOV and Matrix Size on the Quantitative Accuracy of FDG-PET: Comparison between OSEM and Bayesian Penalized Likelihood]. Nihon Hoshasen Gijutsu Gakkai Zasshi 2021; 77:454-462. [PMID: 34011788 DOI: 10.6009/jjrt.2021_jsrt_77.5.454] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/11/2022]
Abstract
PURPOSE Field of view (FOV) and matrix size determine the pixel size of positron emission tomography (PET) images; however, the effect of any variation in these parameters on the quantitative accuracy is unclear. The FOV and matrix size of PET images are adjusted as per each clinical objective. Therefore, this study aimed to evaluate the quantitative accuracy of PET images under different FOV and matrix sizes. METHOD A National Electrical Manufacturers Association (NEMA) body phantom set was filled with 18F-FDG solution, and imaging data were acquired for 30 min. Images were reconstructed using ordered subset expectation maximization (OSEM) and Bayesian penalized likelihood (BPL), both of which were combined with point spread function (PSF) and time of flight (TOF). In each reconstruction method, the image parameters were set to the following: FOV, 20-70 cm; matrix size, 128×128 to 384×384; and pixel size, 1-3 mm. The images were evaluated by physical assessment of the recovery coefficient (RC) and maximum standardized uptake value ratio (SUVmax ratio). RESULT The RC of OSEM images was not affected by changes in FOV, whereas the RC of BPL images decreased in small spheres, when FOV was 20 and 30 cm. The SUVmax ratio of the OSEM images was not affected by the difference in pixel size. However, the SUVmax ratio of BPL images degraded in the 1-mm pixel size; this influence was observed only when the FOV was changed. Conclusion: BPL images reconstructed using a small FOV might degrade the quantitative accuracy of small spheres.
Collapse
Affiliation(s)
- Shinya Mikami
- Department of Radiological Technology, Hamamatsu Medical Center.,Hamamatsu Medical Imaging Center, Hamamatsu Medical Photonics Foundation
| | | | - Akihiro Nakamura
- Hamamatsu Medical Imaging Center, Hamamatsu Medical Photonics Foundation
| | - Tatsuo Torizuka
- Hamamatsu Medical Imaging Center, Hamamatsu Medical Photonics Foundation
| |
Collapse
|
13
|
Zaragori T, Oster J, Roch V, Hossu G, Chawki MB, Grignon R, Pouget C, Gauchotte G, Rech F, Blonski M, Taillandier L, Imbert L, Verger A. 18F-FDOPA PET for the non-invasive prediction of glioma molecular parameters: a radiomics study. J Nucl Med 2021; 63:147-157. [PMID: 34016731 DOI: 10.2967/jnumed.120.261545] [Citation(s) in RCA: 26] [Impact Index Per Article: 8.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/09/2020] [Revised: 04/06/2021] [Indexed: 11/16/2022] Open
Abstract
Purpose: The assessment of gliomas by 18F-FDOPA PET imaging in adjunct to MRI showed high performance by combining static and dynamic features to non-invasively predict the isocitrate dehydrogenase (IDH) mutations and the 1p/19q co-deletion, which the World Health Organization classified as significant parameters in 2016. The current study evaluates whether other 18F-FDOPA PET radiomics features further improve performance and the contributions of each of these features to performance. Methods: Our study included seventy-two, retrospectively selected, newly diagnosed, glioma patients with 18F-FDOPA PET dynamic acquisitions. A set of 114 features, including conventional static features and dynamic features as well as other radiomics features were extracted and machine-learning models trained to predict IDH mutations and the 1p/19q co-deletion. Models were based on a machine-learning algorithm built from stable, relevant, and uncorrelated features selected by hierarchical clustering followed by a bootstrapped feature selection process. Models were assessed by comparing area under the curve (AUC) using a nested cross-validation approach. Feature importance was assessed using SHapley Additive exPlanations (SHAP) values. Results: The best models were able to predict IDH mutations (logistic regression with L2 regularization) and the 1p/19q co-deletion (support vector machine with radial basis function kernel) with an AUC of 0.831[0.790;0.873] and 0.724[0.669;0.782] respectively. For the prediction of IDH mutations, dynamic features were the most important features in the model (TTP: 35.5%). In contrast, other radiomics features were the most useful for predicting the 1p/19q co-deletion (up to 14.5% of importance for the small zone low grey level emphasis) . Conclusion: 18F-FDOPA PET is an effective tool for the non-invasive prediction of glioma molecular parameters using a full set of amino-acid PET radiomics features. The contribution of each feature set shows the importance of systematically integrating dynamic acquisition for the prediction of the IDH mutations as well as developing the use of radiomics features in routine practice for the prediction the 1p/19q co-deletion.
Collapse
Affiliation(s)
- Timothée Zaragori
- CHRU-Nancy, Department of Nuclear Medicine & Nancyclotep Imaging platform and INSERM, IADI, UMR 1254
| | | | - Veronique Roch
- CHRU-Nancy, Department of Nuclear Medicine & Nancyclotep Imaging platform
| | - Gabriela Hossu
- INSERM, IADI, UMR 1254 and CHRU Nancy, CIC 1433 Innovation Technologique
| | | | - Rachel Grignon
- CHRU-Nancy, Department of Nuclear Medicine & Nancyclotep Imaging platform
| | - Celso Pouget
- CHRU-Nancy, Department of Pathology and INSERM U1256
| | | | - Fabien Rech
- CHRU-Nancy, Department of Neurosurgery and CRAN, CNRS UMR 7039
| | - Marie Blonski
- CHRU-Nancy, Department of Neuro-oncology and CRAN, CNRS UMR 7039
| | - Luc Taillandier
- CHRU-Nancy, Department of Neuro-oncology and CRAN, CNRS UMR 7039
| | - Laëtitia Imbert
- CHRU-Nancy, Department of Nuclear Medicine & Nancyclotep Imaging platform and INSERM, IADI, UMR 1254
| | - Antoine Verger
- CHRU-Nancy, Department of Nuclear Medicine & Nancyclotep Imaging platform and INSERM, IADI, UMR 1254
| |
Collapse
|
14
|
Verger A, Doyen M, Campion JY, Guedj E. The pons as reference region for intensity normalization in semi-quantitative analysis of brain 18FDG PET: application to metabolic changes related to ageing in conventional and digital control databases. EJNMMI Res 2021; 11:31. [PMID: 33761019 PMCID: PMC7990981 DOI: 10.1186/s13550-021-00771-0] [Citation(s) in RCA: 16] [Impact Index Per Article: 5.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/18/2021] [Accepted: 03/03/2021] [Indexed: 02/06/2023] Open
Abstract
Background The objective of the study is to define the most appropriate region for intensity normalization in brain 18FDG PET semi-quantitative analysis. The best option could be based on previous absolute quantification studies, which showed that the metabolic changes related to ageing affect the quasi-totality of brain regions in healthy subjects. Consequently, brain metabolic changes related to ageing were evaluated in two populations of healthy controls who underwent conventional (n = 56) or digital (n = 78) 18FDG PET/CT. The median correlation coefficients between age and the metabolism of each 120 atlas brain region were reported for 120 distinct intensity normalizations (according to the 120 regions). SPM linear regression analyses with age were performed on most significant normalizations (FWE, p < 0.05). Results The cerebellum and pons were the two sole regions showing median coefficients of correlation with age less than − 0.5. With SPM, the intensity normalization by the pons provided at least 1.7- and 2.5-fold more significant cluster volumes than other normalizations for conventional and digital PET, respectively. Conclusions The pons is the most appropriate area for brain 18FDG PET intensity normalization for examining the metabolic changes through ageing.
Collapse
Affiliation(s)
- A Verger
- Department of Nuclear Medicine and Nancyclotep Imaging Platform, Université de Lorraine, 54000, Nancy, France.,IADI, INSERM U1254, Université de Lorraine, 54000, Nancy, France
| | - M Doyen
- Department of Nuclear Medicine and Nancyclotep Imaging Platform, Université de Lorraine, 54000, Nancy, France.,IADI, INSERM U1254, Université de Lorraine, 54000, Nancy, France
| | - J Y Campion
- CNRS, Ecole Centrale de Marseille, UMR 7249, Institut Fresnel, Aix-Marseille Université, Marseille, France.,CERIMED, Aix-Marseille University, Marseille, France
| | - Eric Guedj
- CNRS, Ecole Centrale de Marseille, UMR 7249, Institut Fresnel, Aix-Marseille Université, Marseille, France. .,CERIMED, Aix-Marseille University, Marseille, France. .,Department of Nuclear Medicine, Assistance Publique Hôpitaux de Marseille, Timone University Hospital, Marseille, France.
| |
Collapse
|
15
|
Abstract
AIM To assess if digital PET/CT improves liver lesion detectability compared to analog PET/CT in patients with known or suspected liver metastases. MATERIALS AND METHODS We prospectively included 83 cancer patients, with one or more of these conditions: history of liver metastases, clinical risk of having liver metastases or presence of suspected liver metastases on the first of the two PET/CTs. All patients were consecutively scanned on each PET/CT on the same day after a single [18F]fluorodeoxyglucose dose injection. The order of acquisition was randomly assigned. Three nuclear medicine physicians assessed both PET/CTs by counting the foci of high uptake suspicious of liver metastases. Findings were correlated with appropriate reference standards; 19 patients were excluded from the analysis due to insufficient lesion nature confirmation. The final sample consisted of 64 patients (34 women, mean age 68 ± 12 years). RESULTS As per-patient analysis, the mean number of liver lesions detected by the digital PET/CT (3.84 ± 4.25) was significantly higher than that detected by the analog PET/CT (2.91 ± 3.31); P < 0.001. Fifty-five patients had a positive PET/CT study for liver lesions. In 26/55 patients (47%), the digital PET/CT detected more lesions; 7/26 patients (27%) had detectable lesions only by the digital system and had <10 mm of diameter. Twenty-nine patients had the same number of liver lesions detected by both systems. In nine patients both PET/CT systems were negative for liver lesions. CONCLUSION Digital PET/CT offers improved detectability of liver lesions over the analog PET/CT in patients with known or suspected liver metastases.
Collapse
|
16
|
Suzuki M, Fushimi Y, Okada T, Hinoda T, Nakamoto R, Arakawa Y, Sawamoto N, Togashi K, Nakamoto Y. Quantitative and qualitative evaluation of sequential PET/MRI using a newly developed mobile PET system for brain imaging. Jpn J Radiol 2021; 39:669-680. [PMID: 33641056 DOI: 10.1007/s11604-021-01105-9] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/25/2020] [Accepted: 02/15/2021] [Indexed: 10/22/2022]
Abstract
PURPOSE To evaluate the clinical feasibility of a newly developed mobile PET system with MR-compatibility (flexible PET; fxPET), compared with conventional PET (cPET)/CT for brain imaging. METHODS Twenty-one patients underwent cPET/CT with subsequent fxPET/MRI using 18F-FDG. As qualitative evaluation, we visually rated image quality of MR and PET images using a four-point scoring system. We evaluated overall image quality for MR, while we evaluated overall image quality, sharpness and lesion contrast. As quantitative evaluation, we compared registration accuracy between two modalities [(fxPET and MRI) and (cPET and CT)] measuring spatial coordinates. We also examined the accuracy of regional 18F-FDG uptake. RESULTS All acquired images were of diagnostic quality and the number of detected lesions did not differ significantly between fxPET/MR and cPET/CT. Mean misregistration was significantly larger with fxPET/MRI than with cPET/CT. SUVmax and SUVmean for fxPET and cPET showed high correlations in the lesions (R = 0.84, 0.79; P < 0.001, P = 0.002, respectively). In normal structures, we also showed high correlations of SUVmax (R = 0.85, 0.87; P < 0.001, P < 0.001, respectively) and SUVmean (R = 0.83, 0.87; P < 0.001, P < 0.001, respectively) in bilateral caudate nuclei and a moderate correlation of SUVmax (R = 0.65) and SUVmean (R = 0.63) in vermis. CONCLUSIONS The fxPET/MRI system showed image quality within the diagnostic range, registration accuracy below 3 mm and regional 18F-FDG uptake highly correlated with that of cPET/CT.
Collapse
Affiliation(s)
- Mizue Suzuki
- Department of Diagnostic Imaging and Nuclear Medicine, Kyoto University Graduate School of Medicine, 54 Shogoin Kawahara-cho, Sakyo-ku, Kyoto, 606-8507, Japan
| | - Yasutaka Fushimi
- Department of Diagnostic Imaging and Nuclear Medicine, Kyoto University Graduate School of Medicine, 54 Shogoin Kawahara-cho, Sakyo-ku, Kyoto, 606-8507, Japan.
| | - Tomohisa Okada
- Human Brain Research Center, Kyoto University Graduate School of Medicine, 54 Shogoin Kawahara-cho, Sakyo-ku, Kyoto, 606-8507, Japan
| | - Takuya Hinoda
- Department of Diagnostic Imaging and Nuclear Medicine, Kyoto University Graduate School of Medicine, 54 Shogoin Kawahara-cho, Sakyo-ku, Kyoto, 606-8507, Japan
| | - Ryusuke Nakamoto
- Department of Diagnostic Imaging and Nuclear Medicine, Kyoto University Graduate School of Medicine, 54 Shogoin Kawahara-cho, Sakyo-ku, Kyoto, 606-8507, Japan
| | - Yoshiki Arakawa
- Department of Neurosurgery, Kyoto University Graduate School of Medicine, 54 Shogoin Kawahara-cho, Sakyo-ku, Kyoto, 606-8507, Japan
| | - Nobukatsu Sawamoto
- Department of Human Health Sciences, Kyoto University Graduate School of Medicine, 54 Shogoin Kawahara-cho, Sakyo-ku, Kyoto, 606-8507, Japan
| | - Kaori Togashi
- Department of Diagnostic Imaging and Nuclear Medicine, Kyoto University Graduate School of Medicine, 54 Shogoin Kawahara-cho, Sakyo-ku, Kyoto, 606-8507, Japan
| | - Yuji Nakamoto
- Department of Diagnostic Imaging and Nuclear Medicine, Kyoto University Graduate School of Medicine, 54 Shogoin Kawahara-cho, Sakyo-ku, Kyoto, 606-8507, Japan
| |
Collapse
|
17
|
Oddstig J, Brolin G, Trägårdh E, Minarik D. Head-to-head comparison of a Si-photomultiplier-based and a conventional photomultiplier-based PET-CT system. EJNMMI Phys 2021; 8:19. [PMID: 33630173 PMCID: PMC7907292 DOI: 10.1186/s40658-021-00366-7] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/24/2020] [Accepted: 02/09/2021] [Indexed: 01/06/2023] Open
Abstract
BACKGROUND A novel generation of PET scanners based on silicon (Si)-photomultiplier (PM) technology has recently been introduced. Concurrently, there has been development of new reconstruction methods aimed at increasing the detectability of small lesions without increasing image noise. The combination of new detector technologies and new reconstruction algorithms has been found to increase image quality. However, it is unknown to what extent the demonstrated improvement of image quality is due to scanner hardware development or improved reconstruction algorithms. To isolate the contribution of the hardware, this study aimed to compare the ability to detect small hotspots in phantoms using the latest generation SiPM-based PET/CT scanner (GE Discovery MI) relative to conventional PM-based PET/CT scanner (GE Discovery 690), using identical reconstruction protocols. MATERIALS AND METHODS Two different phantoms (NEMA body and Jasczcak) with fillable spheres (31 μl to 26.5 ml) and varying sphere-to-background-ratios (SBR) were scanned in one bed position for 15-600 s on both scanners. The data were reconstructed using identical reconstruction parameters on both scanners. The recovery-coefficient (RC), noise level, contrast (spherepeak/backgroundpeak-value), and detectability of each sphere were calculated and compared between the scanners at each acquisition time. RESULTS The RC-curves for the NEMA phantom were near-identical for both scanners at SBR 10:1. For smaller spheres in the Jaszczak phantom, the contrast was 1.22 higher for the DMI scanner at SBR 15:1. The ratio decreased for lower SBR, with a ratio of 1.03 at SBR 3.85:1. Regarding the detectability of spheres, the sensitivity was 98% and 88% for the DMI and D690, respectively, for SBR 15:1. For SBR 7.5, the sensitivity was 75% and 83% for the DMI and D690, respectively. For SBR 3.85:1, the sensitivity was 43% and 30% for the DMI and D690, respectively. CONCLUSION Marginally higher contrast in small spheres was seen for the SiPM-based scanner but there was no significant difference in detectability between the scanners. It was difficult to detect differences between the scanners, suggesting that the SiPM-based detectors are not the primary reason for improved image quality.
Collapse
Affiliation(s)
- Jenny Oddstig
- Radiation Physics, Department of Hematology, Oncology and Radiation Physics, Skåne University Hospital, 221 85, Lund, Sweden.
| | - Gustav Brolin
- Radiation Physics, Department of Hematology, Oncology and Radiation Physics, Skåne University Hospital, 221 85, Lund, Sweden
| | - Elin Trägårdh
- Clinical Physiology and Nuclear Medicine, Skåne University Hospital and Lund University, Carl Bertil Laurells gata 9, Skåne University Hospital, 205 02, Malmö, Sweden.,Wallenberg Center for Molecular Medicine, Lund University, Carl Bertil Laurells gata 9, Skåne University Hospital, 205 02, Malmö, Sweden
| | - David Minarik
- Radiation Physics, Department of Hematology, Oncology and Radiation Physics, Skåne University Hospital, 221 85, Lund, Sweden
| |
Collapse
|
18
|
Salvadori J, Odille F, Karcher G, Marie PY, Imbert L. Fully digital PET is unaffected by any deterioration in TOF resolution and TOF image quality in the wide range of routine PET count rates. EJNMMI Phys 2021; 8:1. [PMID: 33409746 PMCID: PMC7788141 DOI: 10.1186/s40658-020-00344-5] [Citation(s) in RCA: 11] [Impact Index Per Article: 3.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/03/2020] [Accepted: 11/30/2020] [Indexed: 12/11/2022] Open
Abstract
PURPOSE Digital PET involving silicon photomultipliers (SiPM) provides an enhanced time-of-flight (TOF) resolution as compared with photomultiplier (PMT)-based PET, but also a better prevention of the count-related rises in dead time and pile-up effects mainly due to smaller trigger domains (i.e., the detection surfaces associated with each trigger circuit). This study aimed to determine whether this latter property could help prevent against deteriorations in TOF resolution and TOF image quality in the wide range of PET count rates documented in clinical routine. METHODS Variations, according to count rates, in timing resolution and in TOF-related enhancement of the quality of phantom images were compared between the first fully digital PET (Vereos) and a PMT-based PET (Ingenuity). Single-count rate values were additionally extracted from the list-mode data of routine analog- and digital-PET exams at each 500-ms interval, in order to determine the ranges of routine PET count rates. RESULTS Routine PET count rates were lower for the Vereos than for the Ingenuity. For Ingenuity, the upper limits were estimated at approximately 21.7 and 33.2 Mcps after injection of respectively 3 and 5 MBq.kg-1 of current 18F-labeled tracers. At 5.8 Mcps, corresponding to the lower limit of the routine count rates documented with the Ingenuity, timing resolutions provided by the scatter phantom were 326 and 621 ps for Vereos and Ingenuity, respectively. At higher count rates, timing resolution was remarkably stable for Vereos but exhibited a progressive deterioration for Ingenuity, respectively reaching 732 and 847 ps at the upper limits of 21.7 and 33.2 Mcps. The averaged TOF-related gain in signal/noise ratio was stable at approximately 2 for Vereos but decreased from 1.36 at 5.8 Mcps to 1.14 and 1.00 at respectively 21.7 and 33.2 Mcps for Ingenuity. CONCLUSION Contrary to the Ingenuity PMT-based PET, the Vereos fully digital PET is unaffected by any deterioration in TOF resolution and consequently, in the quality of TOF images, in the wide range of routine PET count rates. This advantage is even more striking with higher count-rates for which the preferential use of digital PET should be further recommended (i.e., dynamic PET recording, higher injected activities).
Collapse
Affiliation(s)
- Julien Salvadori
- Department of Nuclear Medicine and Nancyclotep Molecular Imaging Platform, CHRU-Nancy, Université de Lorraine, F54000, Nancy, France. .,Université de Lorraine, INSERM, UMR 1254, F54000, Nancy, France.
| | - Freddy Odille
- Department of Nuclear Medicine and Nancyclotep Molecular Imaging Platform, CHRU-Nancy, Université de Lorraine, F54000, Nancy, France.,Université de Lorraine, INSERM, UMR 1254, F54000, Nancy, France
| | - Gilles Karcher
- Department of Nuclear Medicine and Nancyclotep Molecular Imaging Platform, CHRU-Nancy, Université de Lorraine, F54000, Nancy, France.,Université de Lorraine, INSERM, UMR 1254, F54000, Nancy, France
| | - Pierre-Yves Marie
- Department of Nuclear Medicine and Nancyclotep Molecular Imaging Platform, CHRU-Nancy, Université de Lorraine, F54000, Nancy, France.,Université de Lorraine, INSERM, UMR 1116, F54000, Nancy, France
| | - Laetitia Imbert
- Department of Nuclear Medicine and Nancyclotep Molecular Imaging Platform, CHRU-Nancy, Université de Lorraine, F54000, Nancy, France.,Université de Lorraine, INSERM, UMR 1254, F54000, Nancy, France
| |
Collapse
|
19
|
Mairal E, Doyen M, Rivasseau-Jonveaux T, Malaplate C, Guedj E, Verger A. Clinical impact of digital and conventional PET control databases for semi-quantitative analysis of brain 18F-FDG digital PET scans. EJNMMI Res 2020; 10:144. [PMID: 33258085 PMCID: PMC7704892 DOI: 10.1186/s13550-020-00733-y] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/31/2020] [Accepted: 11/23/2020] [Indexed: 02/07/2023] Open
Abstract
PURPOSE Digital PET cameras markedly improve sensitivity and spatial resolution of brain 18F-FDG PET images compared to conventional cameras. Our study aimed to assess whether specific control databases are required to improve the diagnostic performance of these recent advances. METHODS We retrospectively selected two groups of subjects, twenty-seven Alzheimer's Disease (AD) patients and twenty-two healthy control (HC) subjects. All subjects underwent a brain 18F-FDG PET on a digital camera (Vereos, Philips®). These two group (AD and HC) are compared, using a Semi-Quantitative Analysis (SQA), to two age and sex matched controls acquired with a digital PET/CT (Vereos, Philips®) or a conventional PET/CT (Biograph 6, Siemens®) camera, at group and individual levels. Moreover, individual visual interpretation of SPM T-maps was provided for the positive diagnosis of AD by 3 experienced raters. RESULTS At group level, SQA using digital controls detected more marked hypometabolic areas in AD (+ 116 cm3 at p < 0.001 uncorrected for the voxel, corrected for the cluster) than SQA using conventional controls. At the individual level, the accuracy of SQA for discriminating AD using digital controls was higher than SQA using conventional controls (86% vs. 80%, p < 0.01, at p < 0.005 uncorrected for the voxel, corrected for the cluster), with higher sensitivity (89% vs. 78%) and similar specificity (82% vs. 82%). These results were confirmed by visual analysis (accuracies of 84% and 82% for digital and conventional controls respectively, p = 0.01). CONCLUSION There is an urgent need to establish specific digital PET control databases for SQA of brain 18F-FDG PET images as such databases improve the accuracy of AD diagnosis.
Collapse
Affiliation(s)
- Elise Mairal
- Department of Nuclear Medicine and Nancyclotep Imaging Platform, CHRU Nancy, Université de Lorraine, Rue du Morvan, 54500, Vandoeuvre-les-Nancy, France
| | - Matthieu Doyen
- Department of Nuclear Medicine and Nancyclotep Imaging Platform, CHRU Nancy, Université de Lorraine, Rue du Morvan, 54500, Vandoeuvre-les-Nancy, France.,IADI, INSERM U1254, Université de Lorraine, 54000, Nancy, France
| | - Thérèse Rivasseau-Jonveaux
- Clinical Memory and Research Center, Department of Geriatrics, CHRU Nancy, Université de Lorraine, 2LPN EA 7489, 54000, Nancy, France
| | - Catherine Malaplate
- Department of Biochemistry, Molecular Biology and Nutrition CHRU Nancy, Université de Lorraine, 54000, Nancy, France
| | - Eric Guedj
- APHM, CNRS, Centrale Marseille, Institut Fresnel, Timone Hospital, CERIMED, Nuclear Medicine Department, Aix Marseille Univ, Marseille, France
| | - Antoine Verger
- Department of Nuclear Medicine and Nancyclotep Imaging Platform, CHRU Nancy, Université de Lorraine, Rue du Morvan, 54500, Vandoeuvre-les-Nancy, France. .,IADI, INSERM U1254, Université de Lorraine, 54000, Nancy, France.
| |
Collapse
|
20
|
Wagatsuma K, Sakata M, Ishibashi K, Hirayama A, Kawakami H, Miwa K, Suzuki Y, Ishii K. Direct comparison of brain [ 18F]FDG images acquired by SiPM-based and PMT-based PET/CT: phantom and clinical studies. EJNMMI Phys 2020; 7:70. [PMID: 33226451 PMCID: PMC7683764 DOI: 10.1186/s40658-020-00337-4] [Citation(s) in RCA: 6] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/24/2020] [Accepted: 11/10/2020] [Indexed: 11/24/2022] Open
Abstract
Background Silicon photomultiplier-positron emission tomography (SiPM-PET) has better sensitivity, spatial resolution, and timing resolution than photomultiplier tube (PMT)-PET. The present study aimed to clarify the advantages of SiPM-PET in 18F-fluoro-2-deoxy-D-glucose ([18F]FDG) brain imaging in a head-to-head comparison with PMT-PET in phantom and clinical studies. Methods Contrast was calculated from images acquired from a Hoffman 3D brain phantom, and image noise and uniformity were calculated from images acquired from a pool phantom using SiPM- and PMT-PET. Sequential PMT-PET and SiPM-PET [18F]FDG images were acquired over a period of 10 min from 22 controls and 10 patients. All images were separately normalized to a standard [18F]FDG PET template, then the mean standardized uptake values (SUVmean) and Z-score were calculated using MIMneuro and CortexID Suite, respectively. Results Image contrast, image noise, and uniformity in SiPM-PET changed 19.2, 3.5, and − 40.0% from PMT-PET, respectively. These physical indices of both PET scanners satisfied the criteria for acceptable image quality published by the Japanese Society of Nuclear Medicine of contrast > 55%, CV ≤ 15%, and SD ≤ 0.0249, respectively. Contrast was 70.0% for SiPM-PET without TOF and 59.5% for PMT-PET without TOF. The TOF improved contrast by 3.5% in SiPM-PET. The SUVmean using SiPM-PET was significantly higher than PMT-PET and did not correlate with a time delay. Z-scores were also significantly higher in images acquired from SiPM-PET (except for the bilateral posterior cingulate) than PMT-PET because the peak signal that was extracted by the calculation of Z-score in CortexID Suite was increased. The hypometabolic area in statistical maps was reduced and localized using SiPM-PET. The trend was independent of whether the images were derived from controls or patients. Conclusions The improved spatial resolution and sensitivity of SiPM-PET contributed to better image contrast and uniformity in brain [18F]FDG images. The SiPM-PET offers better quality and more accurate quantitation of brain PET images. The SUVmean and Z-scores were higher in SiPM-PET than PMT-PET due to improved PVE. [18F]FDG images acquired using SiPM-PET will help to improve diagnostic outcomes based on statistical image analysis because SiPM-PET would localize the distribution of glucose metabolism on Z-score maps. Supplementary Information The online version contains supplementary material available at 10.1186/s40658-020-00337-4.
Collapse
Affiliation(s)
- Kei Wagatsuma
- Research Team for Neuroimaging, Tokyo Metropolitan Institute of Gerontology, 35-2 Sakae-cho, Itabashi-ku, Tokyo, 173-0015, Japan.
| | - Muneyuki Sakata
- Research Team for Neuroimaging, Tokyo Metropolitan Institute of Gerontology, 35-2 Sakae-cho, Itabashi-ku, Tokyo, 173-0015, Japan
| | - Kenji Ishibashi
- Research Team for Neuroimaging, Tokyo Metropolitan Institute of Gerontology, 35-2 Sakae-cho, Itabashi-ku, Tokyo, 173-0015, Japan
| | - Akira Hirayama
- GE Healthcare Japan, 4-7-127 Asahigaoka, Hino, 191-8503, Japan
| | | | - Kenta Miwa
- Department of Radiological Sciences, School of Health Science, International University of Health and Welfare, 2600-1 Kitakanemaru, Ohtawara, 324-8501, Japan
| | - Yukihisa Suzuki
- Research Team for Neuroimaging, Tokyo Metropolitan Institute of Gerontology, 35-2 Sakae-cho, Itabashi-ku, Tokyo, 173-0015, Japan.,Department of Ophthalmology and Visual Science, Tokyo Medical and Dental University, Graduate School, 1-5-45, Yushima, Bunkyo-ku, Tokyo, 113-8510, Japan
| | - Kenji Ishii
- Research Team for Neuroimaging, Tokyo Metropolitan Institute of Gerontology, 35-2 Sakae-cho, Itabashi-ku, Tokyo, 173-0015, Japan
| |
Collapse
|
21
|
Bordonne M, Chawki MB, Marie PY, Zaragori T, Roch V, Grignon R, Imbert L, Verger A. High-quality brain perfusion SPECT images may be achieved with a high-speed recording using 360° CZT camera. EJNMMI Phys 2020; 7:65. [PMID: 33146804 PMCID: PMC7642149 DOI: 10.1186/s40658-020-00334-7] [Citation(s) in RCA: 18] [Impact Index Per Article: 4.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/24/2020] [Accepted: 10/19/2020] [Indexed: 12/11/2022] Open
Abstract
Objective The aim of this study was to compare brain perfusion SPECT obtained from a 360° CZT and a conventional Anger camera. Methods The 360° CZT camera utilizing a brain configuration, with 12 detectors surrounding the head, was compared to a 2-head Anger camera for count sensitivity and image quality on 30-min SPECT recordings from a brain phantom and from 99mTc-HMPAO brain perfusion in 2 groups of 21 patients investigated with the CZT and Anger cameras, respectively. Image reconstruction was adjusted according to image contrast for each camera. Results The CZT camera provided more than 2-fold increase in count sensitivity, as compared with the Anger camera, as well as (1) lower sharpness indexes, giving evidence of higher spatial resolution, for both peripheral/central brain structures, with respective median values of 5.2%/3.7% versus 2.4%/1.9% for CZT and Anger camera respectively in patients (p < 0.01), and 8.0%/6.9% versus 6.2%/3.7% on phantom; and (2) higher gray/white matter contrast on peripheral/central structures, with respective ratio median values of 1.56/1.35 versus 1.11/1.20 for CZT and Anger camera respectively in patients (p < 0.05), and 2.57/2.17 versus 1.40/1.12 on phantom; and (3) no change in noise level. Image quality, scored visually by experienced physicians, was also significantly higher on CZT than on the Anger camera (+ 80%, p < 0.01), and all these results were unchanged on the CZT images obtained with only a 15 min recording time. Conclusion The 360° CZT camera provides brain perfusion images of much higher quality than a conventional Anger camera, even with high-speed recordings, thus demonstrating the potential for repositioning brain perfusion SPECT to the forefront of brain imaging. Supplementary Information The online version contains supplementary material available at 10.1186/s40658-020-00334-7.
Collapse
Affiliation(s)
- Manon Bordonne
- Department of Nuclear Medicine and Nancyclotep Imaging Platform, CHRU-Nancy, Université de Lorraine, F-54000, Nancy, France.,Médecine Nucléaire, CHRU-Nancy Brabois, Allée du Morvan, 54500 Vandoeuvre-lès-, Nancy, France
| | - Mohammad B Chawki
- Department of Nuclear Medicine and Nancyclotep Imaging Platform, CHRU-Nancy, Université de Lorraine, F-54000, Nancy, France
| | - Pierre-Yves Marie
- Department of Nuclear Medicine and Nancyclotep Imaging Platform, CHRU-Nancy, Université de Lorraine, F-54000, Nancy, France.,Université de Lorraine, INSERM, UMR-1116 DCAC, F-54000, Nancy, France
| | | | - Véronique Roch
- Department of Nuclear Medicine and Nancyclotep Imaging Platform, CHRU-Nancy, Université de Lorraine, F-54000, Nancy, France
| | - Rachel Grignon
- Department of Nuclear Medicine and Nancyclotep Imaging Platform, CHRU-Nancy, Université de Lorraine, F-54000, Nancy, France
| | - Laetitia Imbert
- Department of Nuclear Medicine and Nancyclotep Imaging Platform, CHRU-Nancy, Université de Lorraine, F-54000, Nancy, France. .,Médecine Nucléaire, CHRU-Nancy Brabois, Allée du Morvan, 54500 Vandoeuvre-lès-, Nancy, France. .,Université de Lorraine, INSERM U1254, IADI, F-54000, Nancy, France.
| | - Antoine Verger
- Department of Nuclear Medicine and Nancyclotep Imaging Platform, CHRU-Nancy, Université de Lorraine, F-54000, Nancy, France.,Université de Lorraine, INSERM U1254, IADI, F-54000, Nancy, France
| |
Collapse
|
22
|
Lasnon C, Coudrais N, Houdu B, Nganoa C, Salomon T, Enilorac B, Aide N. How fast can we scan patients with modern (digital) PET/CT systems? Eur J Radiol 2020; 129:109144. [PMID: 32593080 DOI: 10.1016/j.ejrad.2020.109144] [Citation(s) in RCA: 13] [Impact Index Per Article: 3.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/29/2019] [Revised: 05/13/2020] [Accepted: 06/16/2020] [Indexed: 12/20/2022]
Abstract
PURPOSE To seek for the minimal duration per bed position with a digital PET system without compromising image quality and lesion detection in patients requiring fast 18F-FDG PET imaging. MATERIALS AND METHODS 19 cancer patients experiencing pain or dyspnea and 9 pediatric patients were scanned on a Vereos system. List mode data were reconstructed with decreasing time frame down to 10 s per bed position. Noise was evaluated in the liver, blood pool and muscle, and using target-to-background ratios. Five PET readers recorded image quality, number of clinically relevant foci and of involved anatomical sites in reconstructions ranging from 60 to 10 s per bed position, compared to the standard 90 s reconstruction. RESULTS The following reconstructions, which harboured a noise not significantly higher than that of the standard reconstruction, were selected for clinical evaluation: 1iterations/10 subsets/20sec (1i10 s20sec), 1i10 s30sec, and 2i10 sPSF60sec. Only the 60 s per bed acquisition displayed similar target-to-background ratios compared to the standard reconstruction, but mean ratios were still higher than 2.0 for the 30 s reconstruction. Inter-rater agreement for the number of involved anatomical sites and detected lesion was good or almost perfect (Kappa: 0.64-0.91) for all acquisitions. In particular, kappa for the 30 s per bed acquisition was 0.78 and 0.91 for lesion and anatomical sites number, respectively. Intra-rater agreement was also excellent for the 30 s reconstruction (kappa = 0.72). Median estimated total PET acquisition time for the 1i10 s30sec, and the standard reconstruction were 4 and 12 min, respectively. CONCLUSIONS Fast imaging is feasible with state-of-the-art PET systems. Acquisitions of 30 s per bed position are feasible with the Vereos system, requiring optimization of reconstruction parameters.
Collapse
Affiliation(s)
- Charline Lasnon
- Centre François Baclesse, Nuclear Medicine Department, Caen, France; INSERM ANTICIPE, Normandie University, Caen, France
| | | | - Benjamin Houdu
- CHU de Caen, Nuclear Medicine Department, Caen, France; Normandie University, France
| | | | | | | | - Nicolas Aide
- CHU de Caen, Nuclear Medicine Department, Caen, France; INSERM ANTICIPE, Normandie University, Caen, France; Normandie University, France.
| |
Collapse
|
23
|
Salvadori J, Labour J, Odille F, Marie PY, Badel JN, Imbert L, Sarrut D. Monte Carlo simulation of digital photon counting PET. EJNMMI Phys 2020; 7:23. [PMID: 32335787 PMCID: PMC7183520 DOI: 10.1186/s40658-020-00288-w] [Citation(s) in RCA: 12] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/13/2019] [Accepted: 03/17/2020] [Indexed: 12/14/2022] Open
Abstract
A GATE Monte Carlo model of the Philips Vereos digital photon counting PET imaging system using silicon photo-multiplier detectors was proposed. It was evaluated against experimental data in accordance with NEMA guidelines. Comparisons were performed using listmode data in order to remain independent of image reconstruction algorithms. An original line of response-based method is proposed to estimate intrinsic spatial resolution without reconstruction. Four sets of experiments were performed: (1) count rates and scatter fraction, (2) energy and timing resolutions, (3) sensitivity, and (4) intrinsic spatial resolution. Experimental and simulated data were found to be in good agreement, with overall differences lower than 10% for activity concentrations used in most standard clinical applications. Illustrative image reconstructions were provided. In conclusion, the proposed Monte Carlo model was validated and can be used for numerous studies such as optimizing acquisition parameters or reconstruction algorithms.
Collapse
Affiliation(s)
- Julien Salvadori
- IADI, INSERM UMR 1254, Université de Lorraine, Nancy, France. .,Département de médecine nucléaire et plateforme Nancyclotep, CHRU-Nancy, Université de Lorraine, Nancy, France.
| | - Joey Labour
- CREATIS, Centre Léon Bérard, CNRS UMR 5220, INSERM U 1044, Université de Lyon; INSA-Lyon; Université Lyon 1, Lyon, France
| | - Freddy Odille
- IADI, INSERM UMR 1254, Université de Lorraine, Nancy, France
| | - Pierre-Yves Marie
- Département de médecine nucléaire et plateforme Nancyclotep, CHRU-Nancy, Université de Lorraine, Nancy, France.,DCAC, INSERM UMR 1116, Université de Lorraine, Nancy, France
| | - Jean-Noël Badel
- CREATIS, Centre Léon Bérard, CNRS UMR 5220, INSERM U 1044, Université de Lyon; INSA-Lyon; Université Lyon 1, Lyon, France
| | - Laëtitia Imbert
- IADI, INSERM UMR 1254, Université de Lorraine, Nancy, France.,Département de médecine nucléaire et plateforme Nancyclotep, CHRU-Nancy, Université de Lorraine, Nancy, France
| | - David Sarrut
- CREATIS, Centre Léon Bérard, CNRS UMR 5220, INSERM U 1044, Université de Lyon; INSA-Lyon; Université Lyon 1, Lyon, France
| |
Collapse
|
24
|
Salvadori J, Odille F, Verger A, Olivier P, Karcher G, Marie PY, Imbert L. Head-to-head comparison between digital and analog PET of human and phantom images when optimized for maximizing the signal-to-noise ratio from small lesions. EJNMMI Phys 2020; 7:11. [PMID: 32086646 PMCID: PMC7035408 DOI: 10.1186/s40658-020-0281-8] [Citation(s) in RCA: 21] [Impact Index Per Article: 5.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/09/2019] [Accepted: 02/13/2020] [Indexed: 02/07/2023] Open
Abstract
Background Routine PET exams are increasingly performed with reduced injected activities, leading to the use of different image reconstruction parameters than the NEMA parameters, in order to prevent from any deleterious decrease in signal-to-noise ratio (SNR) and thus, in lesion detectability. This study aimed to provide a global head-to-head comparison between digital (Vereos, Philips®) and analog (Ingenuity TF, Philips®) PET cameras of the trade-off between SNR and contrast through a wide-ranging number of reconstruction iterations, and with a further reconstruction optimization based on the SNR of small lesions. Methods Image quality parameters were compared between the two cameras on human and phantom images for a number of OSEM reconstruction iterations ranging from 1 to 10, the number of subsets being fixed at 10, and with the further identification of reconstruction parameters maximizing the SNR of spheres and adenopathies nearing 10 mm in diameter. These reconstructions were additionally obtained with and without time-of-flight (TOF) information (TOF and noTOF images, respectively) for further comparisons. Results On both human and phantom TOF images, the compromise between SNR and contrast was consistently more advantageous for digital than analog PET, with the difference being particularly pronounced for the lowest numbers of iterations and the smallest spheres. SNR was maximized with 1 and 2 OSEM iterations for the TOF images from digital and analog PET, respectively, whereas 4 OSEM iterations were required for the corresponding noTOF images from both cameras. On the TOF images obtained with this SNR optimization, digital PET exhibited a 37% to 44% higher SNR as compared with analog PET, depending on sphere size. These relative differences were however much lower for the noTOF images optimized for SNR (− 4 to + 18%), as well as for images reconstructed according to NEMA standards (− 4 to + 12%). Conclusion SNR may be dramatically higher for digital PET than for analog PET, especially when optimized for small lesions. This superiority is mostly attributable to enhanced TOF resolution and is significantly underestimated in NEMA-based analyses.
Collapse
Affiliation(s)
- Julien Salvadori
- Departement of Nuclear Medicine and Nancyclotep molecular imaging platform, CHRU-Nancy, Université de Lorraine, 54000, Nancy, France. .,IADI, INSERM, UMR 1254, Université de Lorraine, 54000, Nancy, France.
| | - Freddy Odille
- IADI, INSERM, UMR 1254, Université de Lorraine, 54000, Nancy, France
| | - Antoine Verger
- Departement of Nuclear Medicine and Nancyclotep molecular imaging platform, CHRU-Nancy, Université de Lorraine, 54000, Nancy, France.,IADI, INSERM, UMR 1254, Université de Lorraine, 54000, Nancy, France
| | - Pierre Olivier
- Departement of Nuclear Medicine and Nancyclotep molecular imaging platform, CHRU-Nancy, Université de Lorraine, 54000, Nancy, France
| | - Gilles Karcher
- Departement of Nuclear Medicine and Nancyclotep molecular imaging platform, CHRU-Nancy, Université de Lorraine, 54000, Nancy, France
| | - Pierre-Yves Marie
- Departement of Nuclear Medicine and Nancyclotep molecular imaging platform, CHRU-Nancy, Université de Lorraine, 54000, Nancy, France.,DCAC, INSERM, UMR 1116, Université de Lorraine, 54000, Nancy, France
| | - Laetitia Imbert
- Departement of Nuclear Medicine and Nancyclotep molecular imaging platform, CHRU-Nancy, Université de Lorraine, 54000, Nancy, France.,IADI, INSERM, UMR 1254, Université de Lorraine, 54000, Nancy, France
| |
Collapse
|
25
|
Affiliation(s)
- Delphine L Chen
- Seattle Cancer Care AllianceUniversity of WashingtonSeattle, Washington
| |
Collapse
|
26
|
Henrich TJ, Hsue PY, VanBrocklin H. Seeing Is Believing: Nuclear Imaging of HIV Persistence. Front Immunol 2019; 10:2077. [PMID: 31572355 PMCID: PMC6751256 DOI: 10.3389/fimmu.2019.02077] [Citation(s) in RCA: 14] [Impact Index Per Article: 2.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/13/2019] [Accepted: 08/16/2019] [Indexed: 12/19/2022] Open
Abstract
A major obstacle to HIV eradication is the presence of infected cells that persist despite suppressive antiretroviral therapy (ART). HIV largely resides outside of the peripheral circulation, and thus, numerous anatomical and lymphoid compartments that have the capacity to harbor HIV are inaccessible to routine sampling. As a result, there is a limited understanding of the tissue burden of HIV infection or anatomical distribution of HIV transcriptional and translational activity. Novel, non-invasive, in vivo methods are urgently needed to address this fundamental gap in knowledge. In this review, we discuss past and current nuclear imaging approaches that have been applied to HIV infection with an emphasis on current strategies to implement positron emission tomography (PET)-based imaging to directly visualize and characterize whole-body HIV burden. These imaging approaches have various limitations, such as the potential for limited PET sensitivity and specificity in the setting of ART suppression or low viral burden. However, recent advances in high-sensitivity, total-body PET imaging platforms and development of new radiotracer technologies that may enhance anatomical penetration of target-specific tracer molecules are discussed. Potential strategies to image non-viral markers of HIV tissue burden or focal immune perturbation are also addressed. Overall, emerging nuclear imaging techniques and platforms may play an important role in the development of novel therapeutic and HIV reservoir eradication strategies.
Collapse
Affiliation(s)
- Timothy J Henrich
- Division of Experimental Medicine, Department of Medicine, University of San Francisco, San Francisco, CA, United States
| | - Priscilla Y Hsue
- Division of Cardiology, Department of Medicine, University of San Francisco, San Francisco, CA, United States
| | - Henry VanBrocklin
- Radiopharmaceutical Research Program, Center for Molecular and Functional Imaging, University of San Francisco, San Francisco, CA, United States
| |
Collapse
|