1
|
Mani G, Porter D, Collins S, Schatz T, Ornberg A, Shulfer R. A review on manufacturing processes of cobalt-chromium alloy implants and its impact on corrosion resistance and biocompatibility. J Biomed Mater Res B Appl Biomater 2024; 112:e35431. [PMID: 38817036 DOI: 10.1002/jbm.b.35431] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/22/2023] [Revised: 03/23/2024] [Accepted: 05/13/2024] [Indexed: 06/01/2024]
Abstract
Cobalt-Chromium (CoCr) alloys are currently used for various cardiovascular, orthopedic, fracture fixation, and dental implants. A variety of processes such as casting, forging, wrought processing, hot isostatic pressing, metal injection molding, milling, selective laser melting, and electron beam melting are used in the manufacture of CoCr alloy implants. The microstructure and precipitates (carbides, nitrides, carbonitrides, and intermetallic compounds) formed within the alloy are primarily determined by the type of manufacturing process employed. Although the effects of microstructure and precipitates on the physical and mechanical properties of CoCr alloys are well reviewed and documented in the literature, the effects on corrosion resistance and biocompatibility are not comprehensively reviewed. This article reviews the various processes used to manufacture CoCr alloy implants and discusses the effects of manufacturing processes on corrosion resistance and biocompatibility. This review concludes that the microstructure and precipitates formed in the alloy are unique to the manufacturing process employed and have a significant impact on the corrosion resistance and biocompatibility of CoCr alloys. Additionally, a historical and scientific overview of corrosion and biocompatibility for metallic implants is included in this review. Specifically, the failure of CoCr alloys when used in metal-on-metal bearing surfaces of total hip replacements is highlighted. It is recommended that the type of implant/application (orthopedic, dental, cardiovascular, etc.) should be the first and foremost factor to be considered when selecting biomaterials for medical device development.
Collapse
Affiliation(s)
- Gopinath Mani
- Global Biocompatibility and Science & Technology Organization, Abbott, St. Paul, Minnesota, USA
| | - Deanna Porter
- Global Biocompatibility and Science & Technology Organization, Abbott, St. Paul, Minnesota, USA
| | - Shell Collins
- Global Biocompatibility and Science & Technology Organization, Abbott, St. Paul, Minnesota, USA
| | - Tim Schatz
- Global Biocompatibility and Science & Technology Organization, Abbott, St. Paul, Minnesota, USA
| | - Andreas Ornberg
- Global Biocompatibility and Science & Technology Organization, Abbott, St. Paul, Minnesota, USA
| | - Robert Shulfer
- Global Biocompatibility and Science & Technology Organization, Abbott, St. Paul, Minnesota, USA
| |
Collapse
|
2
|
Ahadi F, Azadi M, Biglari M, Bodaghi M, Khaleghian A. Evaluation of coronary stents: A review of types, materials, processing techniques, design, and problems. Heliyon 2023; 9:e13575. [PMID: 36846695 PMCID: PMC9950843 DOI: 10.1016/j.heliyon.2023.e13575] [Citation(s) in RCA: 6] [Impact Index Per Article: 6.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/13/2022] [Revised: 01/22/2023] [Accepted: 02/02/2023] [Indexed: 02/11/2023] Open
Abstract
In the world, one of the leading causes of death is coronary artery disease (CAD). There are several ways to treat this disease, and stenting is currently the most appropriate way in many cases. Nowadays, the use of stents has rapidly increased, and they have been introduced in various models, with different geometries and materials. To select the most appropriate stent required, it is necessary to have an analysis of the mechanical behavior of various types of stents. The purpose of this article is to provide a complete overview of advanced research in the field of stents and to discuss and conclude important studies on different topics in the field of stents. In this review, we introduce the types of coronary stents, materials, stent processing technique, stent design, classification of stents based on the mechanism of expansion, and problems and complications of stents. In this article, by reviewing the biomechanical studies conducted in this field and collecting and classifying their results, a useful set of information has been presented to continue research in the direction of designing and manufacturing more efficient stents, although the clinical-engineering field still needs to continue research to optimize the design and construction. The optimum design of stents in the future is possible by simulation and using numerical methods and adequate knowledge of stent and artery biomechanics.
Collapse
Affiliation(s)
- Fatemeh Ahadi
- Faculty of Mechanical Engineering, Semnan University, Semnan, Iran
| | - Mohammad Azadi
- Faculty of Mechanical Engineering, Semnan University, Semnan, Iran
| | - Mojtaba Biglari
- Faculty of Mechanical Engineering, Semnan University, Semnan, Iran
| | - Mahdi Bodaghi
- Department of Engineering, School of Science and Technology, Nottingham Trent University, Nottingham, United Kingdom
| | - Ali Khaleghian
- Department of Biochemistry, Semnan University of Medical Sciences, Semnan, Iran
| |
Collapse
|
3
|
Öner A, Rosam P, Borowski F, Grabow N, Siewert S, Schmidt W, Schmitz KP, Stiehm M. Side-branch expansion capacity of contemporary DES platforms. Eur J Med Res 2021; 26:121. [PMID: 34641963 PMCID: PMC8507243 DOI: 10.1186/s40001-021-00595-7] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/21/2021] [Accepted: 09/27/2021] [Indexed: 11/24/2022] Open
Abstract
Background Percutaneous coronary interventions (PCI) of bifurcation stenoses are both complex and challenging. Stenting strategies share that the stents’ side cells must be carefully explored and appropriately prepared using balloons or stents. So far, stent manufacturers have not provided any information regarding side-branch expansion capacity of their stent platforms. Aims Given that drug-eluting stent (DES) information regarding their mechanical capacity of side-branch expansion is not available, we aimed to evaluate contemporary DES (Orsiro, BIOTRONIK AG; Xience Sierra, Abbott Vascular; Resolute Integrity, Medtronic; Promus Premier Select, Boston Scientific; Supraflex Cruz, Sahajan and Medical Technologies) by their side-branch expansion behavior using in vitro bench testing. Methods In this in vitro study, we analyzed five commercially available DES (diameter 3.0 mm), measuring their side-branch expansion following inflation of different high-pressure non-compliant (NC) balloons (balloon diameter: 2.00–4.00 mm), thereby revealing the morphological characteristics of their side-branch expansion capacities. Results We demonstrated that all tested contemporary DES platforms could withstand large single-cell deformations, up to 4.0 mm. As seen in our side-branch experiments, DES designs consisting of only two connectors between strut rings did not only result in huge cell areas, but also in larger cell diameters following side-branch expansion compared with DES designs using three or more connectors. Furthermore, the stent cell diameter attained was below the balloon diameter at normal pressure. Conclusions We recommend that the expansion capacity of side-branches should be considered in stent selection for bifurcation interventions.
Collapse
Affiliation(s)
- Alper Öner
- Department for Cardiology, Center for Internal Medicine, University Medical Center Rostock, Ernst-Heydemann-Straße 6, 18057, Rostock, Germany. .,Institute for Implant Technology and Biomaterials-IIB E.V, Associated Institute of the University of Rostock, Warnemuende, Rostock, Germany.
| | - Paula Rosam
- Institute for Implant Technology and Biomaterials-IIB E.V, Associated Institute of the University of Rostock, Warnemuende, Rostock, Germany
| | - Finja Borowski
- Institute for Implant Technology and Biomaterials-IIB E.V, Associated Institute of the University of Rostock, Warnemuende, Rostock, Germany
| | - Niels Grabow
- Institute for Biomedical Engineering, University Medical Center Rostock, Warnemuende, Rostock, Germany
| | - Stefan Siewert
- Institute for Implant Technology and Biomaterials-IIB E.V, Associated Institute of the University of Rostock, Warnemuende, Rostock, Germany
| | - Wolfram Schmidt
- Institute for Biomedical Engineering, University Medical Center Rostock, Warnemuende, Rostock, Germany
| | - Klaus-Peter Schmitz
- Institute for Implant Technology and Biomaterials-IIB E.V, Associated Institute of the University of Rostock, Warnemuende, Rostock, Germany
| | - Michael Stiehm
- Institute for Implant Technology and Biomaterials-IIB E.V, Associated Institute of the University of Rostock, Warnemuende, Rostock, Germany
| |
Collapse
|
4
|
Arbeiter D, Reske T, Teske M, Bajer D, Senz V, Schmitz KP, Grabow N, Oschatz S. Influence of Drug Incorporation on the Physico-Chemical Properties of Poly(l-Lactide) Implant Coating Matrices-A Systematic Study. Polymers (Basel) 2021; 13:292. [PMID: 33477626 PMCID: PMC7831498 DOI: 10.3390/polym13020292] [Citation(s) in RCA: 8] [Impact Index Per Article: 2.7] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/23/2020] [Revised: 01/12/2021] [Accepted: 01/13/2021] [Indexed: 12/15/2022] Open
Abstract
Local drug delivery has become indispensable in biomedical engineering with stents being ideal carrier platforms. While local drug release is superior to systemic administration in many fields, the incorporation of drugs into polymers may influence the physico-chemical properties of said matrix. This is of particular relevance as minimally invasive implantation is frequently accompanied by mechanical stresses on the implant and coating. Thus, drug incorporation into polymers may result in a susceptibility to potentially life-threatening implant failure. We investigated spray-coated poly-l-lactide (PLLA)/drug blends using thermal measurements (DSC) and tensile tests to determine the influence of selected drugs, namely sirolimus, paclitaxel, dexamethasone, and cyclosporine A, on the physico-chemical properties of the polymer. For all drugs and PLLA/drug ratios, an increase in tensile strength was observed. As for sirolimus and dexamethasone, PLLA/drug mixed phase systems were identified by shifted drug melting peaks at 200 °C and 240 °C, respectively, whereas paclitaxel and dexamethasone led to cold crystallization. Cyclosporine A did not affect matrix thermal properties. Altogether, our data provide a contribution towards an understanding of the complex interaction between PLLA and different drugs. Our results hold implications regarding the necessity of target-oriented thermal treatment to ensure the shelf life and performance of stent coatings.
Collapse
Affiliation(s)
- Daniela Arbeiter
- Institute for Biomedical Engineering, Rostock University Medical Center, Friedrich-Barnewitz-Straße 4, 18119 Rostock, Germany; (M.T.); (D.B.); (V.S.); (K.-P.S.); (N.G.); (S.O.)
| | - Thomas Reske
- Institute for Implant Technology and Biomaterials e.V., Friedrich-Barnewitz-Straße 4, 18119 Rostock, Germany;
| | - Michael Teske
- Institute for Biomedical Engineering, Rostock University Medical Center, Friedrich-Barnewitz-Straße 4, 18119 Rostock, Germany; (M.T.); (D.B.); (V.S.); (K.-P.S.); (N.G.); (S.O.)
| | - Dalibor Bajer
- Institute for Biomedical Engineering, Rostock University Medical Center, Friedrich-Barnewitz-Straße 4, 18119 Rostock, Germany; (M.T.); (D.B.); (V.S.); (K.-P.S.); (N.G.); (S.O.)
| | - Volkmar Senz
- Institute for Biomedical Engineering, Rostock University Medical Center, Friedrich-Barnewitz-Straße 4, 18119 Rostock, Germany; (M.T.); (D.B.); (V.S.); (K.-P.S.); (N.G.); (S.O.)
| | - Klaus-Peter Schmitz
- Institute for Biomedical Engineering, Rostock University Medical Center, Friedrich-Barnewitz-Straße 4, 18119 Rostock, Germany; (M.T.); (D.B.); (V.S.); (K.-P.S.); (N.G.); (S.O.)
- Institute for Implant Technology and Biomaterials e.V., Friedrich-Barnewitz-Straße 4, 18119 Rostock, Germany;
| | - Niels Grabow
- Institute for Biomedical Engineering, Rostock University Medical Center, Friedrich-Barnewitz-Straße 4, 18119 Rostock, Germany; (M.T.); (D.B.); (V.S.); (K.-P.S.); (N.G.); (S.O.)
| | - Stefan Oschatz
- Institute for Biomedical Engineering, Rostock University Medical Center, Friedrich-Barnewitz-Straße 4, 18119 Rostock, Germany; (M.T.); (D.B.); (V.S.); (K.-P.S.); (N.G.); (S.O.)
| |
Collapse
|
5
|
Jeong DW, Park W, Bedair TM, Kang EY, Kim IH, Park DS, Sim DS, Hong YJ, Koh WG, Jeong MH, Han DK. Augmented re-endothelialization and anti-inflammation of coronary drug-eluting stent by abluminal coating with magnesium hydroxide. Biomater Sci 2019; 7:2499-2510. [PMID: 30957801 DOI: 10.1039/c8bm01696h] [Citation(s) in RCA: 21] [Impact Index Per Article: 4.2] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/08/2023]
Abstract
Drug-eluting stents (DESs) have been widely used as a treatment approach for coronary artery diseases. Generally, conventional DESs were fully covered with drugs and biodegradable polymers on both abluminal and luminal layers (i.e., conformal coating). However, uncontrolled drug release from the luminal drug-coating layer of the stent is known to inhibit re-endothelialization. Furthermore, the acidification of the surrounding tissue by the decomposed coating polymer causes inflammation, resulting in restenosis and late thrombosis. To overcome these limitations, here we demonstrated a functional DES coated with poly(lactic-co-glycolic acid) (PLGA), sirolimus (SRL), and magnesium hydroxide (Mg(OH)2, MH) precisely only on the abluminal layer. The acidic neutralization effect of MH was elucidated by measuring the pH change of the fabricated film in PBS solution. In an in vitro cell study, the stent coated with MH exhibited higher compatibility with human coronary artery endothelial cells (ECs) and a lower inflammation score as compared to the control stent. Finally, in an in vivo large porcine model, the abluminal coated DES with SRL and MH showed excellent re-endothelialization and anti-inflammatory and anti-thrombotic effects. In conclusion, it is believed that this approach has great potential for the development of functional DES for the treatment of cardiovascular diseases.
Collapse
Affiliation(s)
- Da-Won Jeong
- Department of Biomedical Science, CHA University, 335 Pangyo-ro, Bundang-gu, Seongnam, Gyeonggi 13488, Republic of Korea.
| | | | | | | | | | | | | | | | | | | | | |
Collapse
|
6
|
Kim MC, Kim IS, Jeong MH, Sim DS, Hong YJ, Kim JH, Ahn Y, Cho JG, Park JC. Incidence of cardiac death and recurrent stent thrombosis after treatment for angiographically confirmed stent thrombosis. J Cardiol 2019; 74:267-272. [PMID: 30955998 DOI: 10.1016/j.jjcc.2019.02.019] [Citation(s) in RCA: 11] [Impact Index Per Article: 2.2] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 12/19/2018] [Revised: 02/12/2019] [Accepted: 02/25/2019] [Indexed: 12/20/2022]
Abstract
BACKGROUND Although many studies showed the predictive factors of stent thrombosis (ST) occurrence, there are few data about clinical outcomes and recurrent ST after percutaneous coronary intervention (PCI) for ST. Furthermore, it is uncertain which factors can cause adverse clinical events including recurrent ST. METHODS This study examined the clinical outcomes after treatment for definite ST. Among 18,739 patients between June 2003 and December 2016 who underwent PCI using a drug-eluting stent (DES) or bare-metal stent (BMS), 243 consecutive patients who suffered definite ST were enrolled in this study. The overall incidence of ST was 1.3% (DES 1.4% and BMS 0.8%). The study endpoint was 1-year cardiac death or recurrent definite ST after the initial ST. RESULTS Study endpoint occurred in 57 patients (23.5%) during the 1-year follow-up after the initial ST. In multivariate analysis, the factors predicting 1-year endpoint were early ST [adjusted hazard ratio (HR): 2.23, 95% confidence interval (CI): 1.26-4.08, p=0.006], BMS ST (HR: 2.42, 95% CI: 1.27-4.81, p=0.045), serum level of glucose (HR: 1.03, 95% CI: 1.01-1.05, p=0.048), and ST-segment elevation myocardial infarction (STEMI) at the initial ST (HR: 3.73, 95% CI: 1.82-7.65, p<0.001). CONCLUSIONS Recurrent ST or cardiac death during the first year after the initial ST event occurred in ∼25% of patients treated for definite ST. BMS ST, serum level of glucose, STEMI, and early ST at the initial ST were associated with adverse cardiac events.
Collapse
Affiliation(s)
- Min Chul Kim
- Heart Center, Chonnam National University Hospital, Gwangju, Republic of Korea; Division of Cardiology, Department of Internal Medicine, Chonnam National University Hospital, Gwangju, Republic of Korea
| | - In-Soo Kim
- Heart Center, Chonnam National University Hospital, Gwangju, Republic of Korea
| | - Myung Ho Jeong
- Heart Center, Chonnam National University Hospital, Gwangju, Republic of Korea; Division of Cardiology, Department of Internal Medicine, Chonnam National University Hospital, Gwangju, Republic of Korea.
| | - Doo Sun Sim
- Heart Center, Chonnam National University Hospital, Gwangju, Republic of Korea; Division of Cardiology, Department of Internal Medicine, Chonnam National University Hospital, Gwangju, Republic of Korea
| | - Young Joon Hong
- Heart Center, Chonnam National University Hospital, Gwangju, Republic of Korea; Division of Cardiology, Department of Internal Medicine, Chonnam National University Hospital, Gwangju, Republic of Korea
| | - Ju Han Kim
- Heart Center, Chonnam National University Hospital, Gwangju, Republic of Korea; Division of Cardiology, Department of Internal Medicine, Chonnam National University Hospital, Gwangju, Republic of Korea
| | - Youngkeun Ahn
- Heart Center, Chonnam National University Hospital, Gwangju, Republic of Korea; Division of Cardiology, Department of Internal Medicine, Chonnam National University Hospital, Gwangju, Republic of Korea
| | - Jeong Gwan Cho
- Heart Center, Chonnam National University Hospital, Gwangju, Republic of Korea; Division of Cardiology, Department of Internal Medicine, Chonnam National University Hospital, Gwangju, Republic of Korea
| | - Jong Chun Park
- Heart Center, Chonnam National University Hospital, Gwangju, Republic of Korea; Division of Cardiology, Department of Internal Medicine, Chonnam National University Hospital, Gwangju, Republic of Korea
| |
Collapse
|
7
|
Chichareon P, Katagiri Y, Asano T, Takahashi K, Kogame N, Modolo R, Tenekecioglu E, Chang CC, Tomaniak M, Kukreja N, Wykrzykowska JJ, Piek JJ, Serruys PW, Onuma Y. Mechanical properties and performances of contemporary drug-eluting stent: focus on the metallic backbone. Expert Rev Med Devices 2019; 16:211-228. [DOI: 10.1080/17434440.2019.1573142] [Citation(s) in RCA: 17] [Impact Index Per Article: 3.4] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/19/2022]
Affiliation(s)
- Ply Chichareon
- Academic Medical Center, University of Amsterdam, Amsterdam, the Netherlands
- Division of Cardiovascular Medicine, Department of Internal Medicine, Faculty of Medicine, Prince of Songkla University, Hatyai, Songkhla, Thailand
| | - Yuki Katagiri
- Academic Medical Center, University of Amsterdam, Amsterdam, the Netherlands
| | - Taku Asano
- Academic Medical Center, University of Amsterdam, Amsterdam, the Netherlands
| | - Kuniaki Takahashi
- Academic Medical Center, University of Amsterdam, Amsterdam, the Netherlands
| | - Norihiro Kogame
- Academic Medical Center, University of Amsterdam, Amsterdam, the Netherlands
| | - Rodrigo Modolo
- Academic Medical Center, University of Amsterdam, Amsterdam, the Netherlands
- Department of Internal Medicine, Cardiology Division, University of Campinas (UNICAMP). Campinas, Sao Paulo, Brazil
| | | | - Chun-Chin Chang
- ThoraxCenter, Erasmus Medical Center, Rotterdam, the Netherlands
| | - Mariusz Tomaniak
- ThoraxCenter, Erasmus Medical Center, Rotterdam, the Netherlands
- First Department of Cardiology, Medical University of Warsaw, Warsaw, Poland
| | - Neville Kukreja
- Department of Cardiology, East and North Hertfordshire NHS Trust, Hertfordshire, UK
| | | | - Jan J. Piek
- Academic Medical Center, University of Amsterdam, Amsterdam, the Netherlands
| | - Patrick W. Serruys
- International Centre for Circulatory Health, NHLI, Imperial College London, London, UK
| | - Yoshinobu Onuma
- ThoraxCenter, Erasmus Medical Center, Rotterdam, the Netherlands
| |
Collapse
|