1
|
Zeimpekis KG, Sari H, Gözlügöl N, Achangwa NR, Shi K, Schindewolf M, Afshar-Oromieh A, Rominger A, Seifert R. Evaluation of long axial field-of-view (LAFOV) PET/CT for post-treatment dosimetry in Yttrium-90 radioembolization of liver tumors: a comparative study with conventional SPECT imaging. Eur J Nucl Med Mol Imaging 2025; 52:1460-1471. [PMID: 39730786 DOI: 10.1007/s00259-024-07034-9] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/01/2024] [Accepted: 12/15/2024] [Indexed: 12/29/2024]
Abstract
PURPOSE Long axial field-of-view (LAFOV) positron emission tomography/computed tomography (PET/CT) scanners enable high sensitivity and wide anatomical coverage. Therefore, they seem ideal to perform post-selective internal radiation therapy (SIRT) 90Y scans, which are needed, to confirm that the dose is delivered to the tumors and that healthy organs are spared. However, it is unclear to what extent the use of LAFOV PET is feasible and which dosimetry approaches results in accurate measurements. METHODS In this retrospective analysis, a total number of 32 patients was included (median age 71, IQR 14), which had hepatocellular carcinoma, cholangiocarcinoma, or liver metastases. All patients underwent SIRT, and the post-therapy scan was acquired on a single photon emission computed tomography/computed tomography (SPECT/CT) and a LAFOV Biograph Quadra PET/CT with a 20-minute acquisition time. Post-treatment dosimetry, regarding the tumor, whole-liver and lung (LMD) absorbed dose was done using an organ-wise (Simplicit90Y) and a voxel-wise approach (HERMIA Dosimetry) which used a semi-Monte Carlo algorithm. The lung shunt fraction (LSF) was also measured using the voxel-wise approach and compared to the planned. RESULTS The planning, post-treatment SPECT and PET (SPECTpre, SPECTpost, PETpost) median tumor doses based on the organ-wise dosimetry were 276.0 Gy (200.0-330.0 Gy), 232.0 Gy (158.5-303.5 Gy) and 267.5 Gy (182.5-370.8 Gy). In contrast, the median voxel-wise PETpost dose was significantly smaller than the planned SPECTpre (152.5 Gy (94.8-223.8 Gy); p < 0.00001). Moreover, the median tumor absorbed dose at 90% (D90) of the tumor volume was significantly higher in SPECTpost compared with PETpost (123.5 Gy; 81.5-180.0 vs. 30.5 Gy; 11.3-106.3; p < 0.00001). The PETpost measured LSF was significantly lower compared to the planned SPECTpre (0.89%; 0.4-1.3% vs. 2.3%; 1.5-3.6%; p < 0.0001). Similarly, the measured PETpost median LMD was considerably lower to the planned SPECTpre (1.2 Gy; 0.6-2.3 vs. 2.5 Gy; 1.4-4.7; p < 0.0001). CONCLUSION LAFOV PET enabled the direct measurement of post therapy lung dose and tumor doses that correlated well with the planned treatment doses. However, current voxel-wise-based tumor dosimetry seems to be inaccurate for LAFOV PET. In addition, dose volume histogram-based metrics also significantly underestimate the delivered dose. Therefore, improved dosimetry tools are needed for reliable voxel-wise 90Y dosimetry to leverage the sensitivity and spatial resolution of LAFOV PET scanners.
Collapse
Affiliation(s)
- Konstantinos G Zeimpekis
- Department of Nuclear Medicine, Inselspital, Bern University Hospital, University of Bern, Freiburgstrasse 18, Bern, 3010, Switzerland.
| | - Hasan Sari
- Department of Nuclear Medicine, Inselspital, Bern University Hospital, University of Bern, Freiburgstrasse 18, Bern, 3010, Switzerland
- Advanced Clinical Imaging Technology, Siemens Healthcare AG, Lausanne, Switzerland
| | - Nasir Gözlügöl
- Department of Nuclear Medicine, Inselspital, Bern University Hospital, University of Bern, Freiburgstrasse 18, Bern, 3010, Switzerland
| | - Ngwe Rawlings Achangwa
- Department of Nuclear Medicine, Inselspital, Bern University Hospital, University of Bern, Freiburgstrasse 18, Bern, 3010, Switzerland
| | - Kuangyu Shi
- Department of Nuclear Medicine, Inselspital, Bern University Hospital, University of Bern, Freiburgstrasse 18, Bern, 3010, Switzerland
| | - Marc Schindewolf
- Division of Angiology, Swiss Cardiovascular Center, Inselspital, Bern University Hospital, University of Bern, Bern, Switzerland
| | - Ali Afshar-Oromieh
- Department of Nuclear Medicine, Inselspital, Bern University Hospital, University of Bern, Freiburgstrasse 18, Bern, 3010, Switzerland
| | - Axel Rominger
- Department of Nuclear Medicine, Inselspital, Bern University Hospital, University of Bern, Freiburgstrasse 18, Bern, 3010, Switzerland
| | - Robert Seifert
- Department of Nuclear Medicine, Inselspital, Bern University Hospital, University of Bern, Freiburgstrasse 18, Bern, 3010, Switzerland
| |
Collapse
|
2
|
Reinders MTM, Braat AJAT, van Erpecum KJ, de Bruijne J, Bruijnen RCG, Sprengers D, de Man R, Vegt E, IJzermans JNM, Elias SG, Lam MGEH, Smits MLJ. Holmium-166 radioembolisation dosimetry in HCC. Eur J Nucl Med Mol Imaging 2025; 52:993-1003. [PMID: 39470786 PMCID: PMC11754330 DOI: 10.1007/s00259-024-06940-2] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/07/2024] [Accepted: 09/29/2024] [Indexed: 11/01/2024]
Abstract
PURPOSE To evaluate dosimetry, dose-response and dose-toxicity relationships for holmium-166 (166Ho) radioembolisation in patients with hepatocellular carcinoma (HCC). METHODS Thirty-one patients with hepatocellular carcinoma were included in the HEPAR Primary study (NCT03379844, registered on December 20th, 2017) and underwent 166Ho-microspheres radioembolisation. Linear mixed models assessed the association between tumour absorbed doses and response based on mRECIST both on tumour and patient level. Preliminary tumour absorbed dose thresholds were estimated based on predictive value. Linear regression models assessed the association between non-tumour absorbed dose and Common Terminology Criteria for Adverse Events version 4.03. RESULTS Median tumour absorbed dose (tumour level) was 95.5 Gy (range 44-332 Gy). Median non-tumour absorbed dose based on whole liver volume was 19 Gy (range 3 - 48 Gy) and based on target liver volume was 30 Gy (range 13 - 54 Gy). There was a significant association between non-tumour absorbed dose and toxicity. Tumours with partial response/complete response (PR/CR, responders) received a 41% higher absorbed dose than tumours with progressive disease/stable disease (PD/SD, non-responders) (95%CI: 2%-93%, p = 0.04). A predictive value of 90% for tumour response was observed at a tumour absorbed dose threshold of 155 Gy, 100% predictive value was achieved at 184.5 Gy. CONCLUSION This study confirms a positive relationship between tumour absorbed dose and response and between non-tumour absorbed dose and toxicity. Dose thresholds found in this study can serve as a basis for personalized dosimetry in HCC patients treated with 166Ho-microspheres.
Collapse
Affiliation(s)
- Margot T M Reinders
- Department of Radiology & Nuclear Medicine, Utrecht University - University Medical Centre Utrecht, P.O. Box 85500 100, 3500 GA, Utrecht, the Netherlands
| | - Arthur J A T Braat
- Department of Radiology & Nuclear Medicine, Utrecht University - University Medical Centre Utrecht, P.O. Box 85500 100, 3500 GA, Utrecht, the Netherlands
| | - Karel J van Erpecum
- Department of Gastroenterology & Hepatology, Utrecht University - University Medical Centre Utrecht, P.O. Box 85500 100, 3500 GA, Utrecht, the Netherlands
| | - Joep de Bruijne
- Department of Gastroenterology & Hepatology, Utrecht University - University Medical Centre Utrecht, P.O. Box 85500 100, 3500 GA, Utrecht, the Netherlands
| | - Rutger C G Bruijnen
- Department of Radiology & Nuclear Medicine, Utrecht University - University Medical Centre Utrecht, P.O. Box 85500 100, 3500 GA, Utrecht, the Netherlands
| | - Dave Sprengers
- Department of Gastroenterology & Hepatology, Erasmus MC-University Medical Centre Rotterdam, P.O. Box 2040, 3000 CA, Rotterdam, the Netherlands
| | - Rob de Man
- Department of Gastroenterology & Hepatology, Erasmus MC-University Medical Centre Rotterdam, P.O. Box 2040, 3000 CA, Rotterdam, the Netherlands
| | - Erik Vegt
- Department of Radiology & Nuclear Medicine, Erasmus MC-University Medical Centre Rotterdam, P.O. Box 2040, 3000 CA, Rotterdam, the Netherlands
| | - Jan N M IJzermans
- Department of Surgery, Erasmus MC-University Medical Centre Rotterdam, P.O. Box 2040, 3000 CA, Rotterdam, the Netherlands
| | - Sjoerd G Elias
- Julius Centre for Health Sciences and Primary Care, Utrecht University - University Medical Centre Utrecht, P.O. Box 85500 100, 3500 GA, Utrecht, the Netherlands
| | - Marnix G E H Lam
- Department of Radiology & Nuclear Medicine, Utrecht University - University Medical Centre Utrecht, P.O. Box 85500 100, 3500 GA, Utrecht, the Netherlands
| | - Maarten L J Smits
- Department of Radiology & Nuclear Medicine, Utrecht University - University Medical Centre Utrecht, P.O. Box 85500 100, 3500 GA, Utrecht, the Netherlands.
| |
Collapse
|
3
|
Calatayud-Jordán J, Carrasco-Vela N, Chimeno-Hernández J, Carles-Fariña M, Olivas-Arroyo C, Bello-Arqués P, Pérez-Enguix D, Martí-Bonmatí L, Torres-Espallardo I. Y-90 PET/MR imaging optimization with a Bayesian penalized likelihood reconstruction algorithm. Phys Eng Sci Med 2024; 47:1397-1413. [PMID: 38884672 DOI: 10.1007/s13246-024-01452-7] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/17/2024] [Accepted: 05/23/2024] [Indexed: 06/18/2024]
Abstract
Positron Emission Tomography (PET) imaging after90 Y liver radioembolization is used for both lesion identification and dosimetry. Bayesian penalized likelihood (BPL) reconstruction algorithms are an alternative to ordered subset expectation maximization (OSEM) with improved image quality and lesion detectability. The investigation of optimal parameters for90 Y image reconstruction of Q.Clear, a commercial BPL algorithm developed by General Electric (GE), in PET/MR is a field of interest and the subject of this study. The NEMA phantom was filled at an 8:1 sphere-to-background ratio. Acquisitions were performed on a PET/MR scanner for clinically relevant activities between 0.7 and 3.3 MBq/ml. Reconstructions with Q.Clear were performed varying the β penalty parameter between 20 and 6000, the acquisition time between 5 and 20 min and pixel size between 1.56 and 4.69 mm. OSEM reconstructions of 28 subsets with 2 and 4 iterations with and without Time-of-Flight (TOF) were compared to Q.Clear with β = 4000. Recovery coefficients (RC), their coefficient of variation (COV), background variability (BV), contrast-to-noise ratio (CNR) and residual activity in the cold insert were evaluated. Increasing β parameter lowered RC, COV and BV, while CNR was maximized at β = 4000; further increase resulted in oversmoothing. For quantification purposes, β = 1000-2000 could be more appropriate. Longer acquisition times resulted in larger CNR due to reduced image noise. Q.Clear reconstructions led to higher CNR than OSEM. A β of 4000 was obtained for optimal image quality, although lower values could be considered for quantification purposes. An optimal acquisition time of 15 min was proposed considering its clinical use.
Collapse
Affiliation(s)
- José Calatayud-Jordán
- Department of Nuclear Medicine, La Fe University and Polytechnical Hospital, Av. Fernando Abril Martorell 106, 46026, Valencia, Spain.
| | - Nuria Carrasco-Vela
- Radiophysics and Radiological Protection Service, Clinical University Hospital of Valencia, Av. Blasco Ibáñez 17, 46010, Valencia, Spain
| | - José Chimeno-Hernández
- Department of Nuclear Medicine, La Fe University and Polytechnical Hospital, Av. Fernando Abril Martorell 106, 46026, Valencia, Spain
| | - Montserrat Carles-Fariña
- Biomedical Imaging Research Group (GIBI230) at Health Research Institute Hospital La Fe (IIS La Fe), La Fe University and Polytechnical Hospital, Av. Fernando Abril Martorell 106, 46026, Valencia, Spain
| | - Consuelo Olivas-Arroyo
- Department of Nuclear Medicine, La Fe University and Polytechnical Hospital, Av. Fernando Abril Martorell 106, 46026, Valencia, Spain
| | - Pilar Bello-Arqués
- Department of Nuclear Medicine, La Fe University and Polytechnical Hospital, Av. Fernando Abril Martorell 106, 46026, Valencia, Spain
| | - Daniel Pérez-Enguix
- Department of Radiology, La Fe University and Polytechnical Hospital, Av. Fernando Abril Martorell 106, 46026, Valencia, Spain
| | - Luis Martí-Bonmatí
- Biomedical Imaging Research Group (GIBI230) at Health Research Institute Hospital La Fe (IIS La Fe), La Fe University and Polytechnical Hospital, Av. Fernando Abril Martorell 106, 46026, Valencia, Spain
- Department of Radiology, La Fe University and Polytechnical Hospital, Av. Fernando Abril Martorell 106, 46026, Valencia, Spain
| | - Irene Torres-Espallardo
- Department of Nuclear Medicine, La Fe University and Polytechnical Hospital, Av. Fernando Abril Martorell 106, 46026, Valencia, Spain
- Biomedical Imaging Research Group (GIBI230) at Health Research Institute Hospital La Fe (IIS La Fe), La Fe University and Polytechnical Hospital, Av. Fernando Abril Martorell 106, 46026, Valencia, Spain
| |
Collapse
|
4
|
Dietze MMA, Meddens MBM, van Rooij R, Braat AJAT, de Keizer B, Bruijnen RCG, Lam MGEH, Smits MLJ, de Jong HWAM. Safety and Feasibility of Interventional Hybrid Fluoroscopy and Nuclear Imaging in the Work-up Procedure of Hepatic Radioembolization. Radiol Imaging Cancer 2024; 6:e240044. [PMID: 39485113 PMCID: PMC11615633 DOI: 10.1148/rycan.240044] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/13/2024] [Revised: 09/04/2024] [Accepted: 09/24/2024] [Indexed: 11/03/2024]
Abstract
Purpose To evaluate the safety and feasibility of a novel hybrid nuclear and fluoroscopy C-arm scanner to be used during the work-up procedure of hepatic radioembolization. Materials and Methods In this prospective first-in-human clinical study, 12 participants (median age, 67 years [range: 37-78 years]; nine [75%] male, three [25%] female) with liver tumors undergoing work-up for yttrium 90 radioembolization were included (ClinicalTrials.gov NCT06013774). Work-up angiography and technetium 99m-macroaggregated albumin injection were performed in an angiography suite equipped with a hybrid C-arm that could simultaneously perform fluoroscopy and planar nuclear imaging. Technetium 99m-macroaggregated albumin was injected under real-time hybrid imaging, followed by in-room SPECT imaging. Safety and feasibility were studied by assessing adverse events, technical performance, additional x-ray radiation dose, and questionnaires completed by radiologists and technologists. Results No adverse events were attributed to the hybrid C-arm scanner. The additional x-ray radiation dose was low (median, 19 Gy · cm2; minimum: 12 Gy · cm2; maximum: 21 Gy · cm2 for participants who completed all imaging steps). The interventional personnel considered use of the hybrid C-arm scanner safe and feasible, although the additional time spent in the intervention room was considered long (median, 64 minutes; minimum: 55 minutes; maximum: 77 minutes for participants who completed all imaging steps). Conclusion Use of the hybrid C-arm scanner during the work-up procedure of hepatic radioembolization was found to be safe and feasible in this first-in-human clinical study. Keywords: Angiography, Fluoroscopy, Interventional-Vascular, Radionuclide Studies, Radiosurgery, Gamma Knife, Cyberknife, SPECT, Instrumentation, Physics, Technical Aspects, Technology Assessment Supplemental material is available for this article. Published under a CC BY 4.0 license. Clinical trial registration no. NCT06013774.
Collapse
Affiliation(s)
- Martijn M. A. Dietze
- From the Department of Radiology and Nuclear Medicine, University
Medical Center Utrecht, Heidelberglaan 100, 3584 CX, PO Box 85500, 3508 GA
Utrecht, the Netherlands
| | - Marjolein B. M. Meddens
- From the Department of Radiology and Nuclear Medicine, University
Medical Center Utrecht, Heidelberglaan 100, 3584 CX, PO Box 85500, 3508 GA
Utrecht, the Netherlands
| | - Rob van Rooij
- From the Department of Radiology and Nuclear Medicine, University
Medical Center Utrecht, Heidelberglaan 100, 3584 CX, PO Box 85500, 3508 GA
Utrecht, the Netherlands
| | - Arthur J. A. T. Braat
- From the Department of Radiology and Nuclear Medicine, University
Medical Center Utrecht, Heidelberglaan 100, 3584 CX, PO Box 85500, 3508 GA
Utrecht, the Netherlands
| | - Bart de Keizer
- From the Department of Radiology and Nuclear Medicine, University
Medical Center Utrecht, Heidelberglaan 100, 3584 CX, PO Box 85500, 3508 GA
Utrecht, the Netherlands
| | - Rutger C. G. Bruijnen
- From the Department of Radiology and Nuclear Medicine, University
Medical Center Utrecht, Heidelberglaan 100, 3584 CX, PO Box 85500, 3508 GA
Utrecht, the Netherlands
| | - Marnix G. E. H. Lam
- From the Department of Radiology and Nuclear Medicine, University
Medical Center Utrecht, Heidelberglaan 100, 3584 CX, PO Box 85500, 3508 GA
Utrecht, the Netherlands
| | - Maarten L. J. Smits
- From the Department of Radiology and Nuclear Medicine, University
Medical Center Utrecht, Heidelberglaan 100, 3584 CX, PO Box 85500, 3508 GA
Utrecht, the Netherlands
| | - Hugo W. A. M. de Jong
- From the Department of Radiology and Nuclear Medicine, University
Medical Center Utrecht, Heidelberglaan 100, 3584 CX, PO Box 85500, 3508 GA
Utrecht, the Netherlands
| |
Collapse
|
5
|
Mansur A, Habibollahi P, Fang A, Mahvash A, Etezadi V, Liddell RP, Camacho JC, Cohen EI, Kokabi N, Arepally A, Georgiades C, Nezami N. New frontiers in radioembolization. Ther Adv Med Oncol 2024; 16:17588359241280692. [PMID: 39371617 PMCID: PMC11456171 DOI: 10.1177/17588359241280692] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/17/2024] [Accepted: 08/19/2024] [Indexed: 10/08/2024] Open
Abstract
Radioembolization is a locoregional transarterial therapy that combines radionuclide and micron-sized beads to deliver radiation internally to the target tumors based on the arterial blood flow. While initially developed as a palliative treatment option, radioembolization is now used for curative intent treatment, neoadjuvant therapy, and method to downstage or bridge for liver transplant. Radioembolization has become increasingly utilized and is an important therapeutic option for the management of hepatocellular carcinoma and liver metastasis. This article provides an overview of the techniques, challenges, and novel developments in radioembolization, including new dosimetry techniques, radionuclides, and new target tumors.
Collapse
Affiliation(s)
| | - Peiman Habibollahi
- Division of Diagnostic Imaging, Department of Interventional Radiology, The University of Texas MD Anderson Cancer Center, Houston, TX, USA
| | - Adam Fang
- Division of Vascular and Interventional Radiology, Department of Diagnostic Radiology and Nuclear Medicine, University of Maryland School of Medicine, Baltimore, MD, USA
| | - Armeen Mahvash
- Division of Diagnostic Imaging, Department of Interventional Radiology, The University of Texas MD Anderson Cancer Center, Houston, TX, USA
| | - Vahid Etezadi
- Division of Vascular and Interventional Radiology, Department of Diagnostic Radiology and Nuclear Medicine, University of Maryland School of Medicine, Baltimore, MD, USA
| | - Robert P. Liddell
- Division of Vascular and Interventional Radiology, Russell H. Morgan Department of Radiology and Radiological Science, The Johns Hopkins University School of Medicine, Baltimore, MD, USA
| | - Juan C. Camacho
- Department of Clinical Sciences, College of Medicine, Florida State University, Tallahassee, FL, USA
- Vascular and Interventional Radiology, Radiology Associates of Florida, Sarasota, FL, USA
| | - Emil I. Cohen
- Division of Vascular and Interventional Radiology, Department of Radiology, Georgetown University School of Medicine, Washington, DC, USA
| | - Nima Kokabi
- Department of Radiology, University of North Carolina at Chapel Hill, Chapel Hill, NC, USA
| | - Aravind Arepally
- Radiology Associates of Atlanta, Atlanta, GA, USA
- ABK Biomedical Inc., Atlanta, GA, USA
| | - Christos Georgiades
- Division of Vascular and Interventional Radiology, Russell H. Morgan Department of Radiology and Radiological Science, The Johns Hopkins University School of Medicine, Baltimore, MD, USA
| | - Nariman Nezami
- Division of Vascular and Interventional Radiology, Department of Radiology, Georgetown University School of Medicine, 3800 Reservoir Road, NW, CCC Bldg., Room CG225, Washington, DC 20007, USA
| |
Collapse
|
6
|
Kerckhaert CEM, de Jong HWAM, Meddens MBM, van Rooij R, Smits MLJ, Rakvongthai Y, Dietze MMA. Subtraction of single-photon emission computed tomography (SPECT) in radioembolization: a comparison of four methods. EJNMMI Phys 2024; 11:72. [PMID: 39143361 PMCID: PMC11324633 DOI: 10.1186/s40658-024-00675-7] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/21/2024] [Accepted: 08/05/2024] [Indexed: 08/16/2024] Open
Abstract
BACKGROUND Subtraction of single-photon emission computed tomography (SPECT) images has a number of clinical applications in e.g. foci localization in ictal/inter-ictal SPECT and defect detection in rest/stress cardiac SPECT. In this work, we investigated the technical performance of SPECT subtraction for the purpose of quantifying the effect of a vasoconstricting drug (angiotensin-II, or AT2) on the Tc-99m-MAA liver distribution in hepatic radioembolization using an innovative interventional hybrid C-arm scanner. Given that subtraction of SPECT images is challenging due to high noise levels and poor resolution, we compared four methods to obtain a difference image in terms of image quality and quantitative accuracy. These methods included (i) image subtraction: subtraction of independently reconstructed SPECT images, (ii) projection subtraction: reconstruction of a SPECT image from subtracted projections, (iii) projection addition: reconstruction by addition of projections as a background term during the iterative reconstruction, and (iv) image addition: simultaneous reconstruction of the difference image and the subtracted image. RESULTS Digital simulations (XCAT) and phantom studies (NEMA-IQ and anthropomorphic torso) showed that all four methods were able to generate difference images but their performance on specific metrics varied substantially. Image subtraction had the best quantitative performance (activity recovery coefficient) but had the worst visual quality (contrast-to-noise ratio) due to high noise levels. Projection subtraction showed a slightly better visual quality than image subtraction, but also a slightly worse quantitative accuracy. Projection addition had a substantial bias in its quantitative accuracy which increased with less counts in the projections. Image addition resulted in the best visual image quality but had a quantitative bias when the two images to subtract contained opposing features. CONCLUSION All four investigated methods of SPECT subtraction demonstrated the capacity to generate a feasible difference image from two SPECT images. Image subtraction is recommended when the user is only interested in quantitative values, whereas image addition is recommended when the user requires the best visual image quality. Since quantitative accuracy is most important for the dosimetric investigation of AT2 in radioembolization, we recommend using the image subtraction method for this purpose.
Collapse
Affiliation(s)
- Camiel E M Kerckhaert
- Radiology and Nuclear Medicine, Utrecht University and University Medical Center Utrecht, P.O. Box 85500, 3508 GA, Utrecht, Netherlands.
| | - Hugo W A M de Jong
- Radiology and Nuclear Medicine, Utrecht University and University Medical Center Utrecht, P.O. Box 85500, 3508 GA, Utrecht, Netherlands
| | - Marjolein B M Meddens
- Radiology and Nuclear Medicine, Utrecht University and University Medical Center Utrecht, P.O. Box 85500, 3508 GA, Utrecht, Netherlands
| | - Rob van Rooij
- Radiology and Nuclear Medicine, Utrecht University and University Medical Center Utrecht, P.O. Box 85500, 3508 GA, Utrecht, Netherlands
| | - Maarten L J Smits
- Radiology and Nuclear Medicine, Utrecht University and University Medical Center Utrecht, P.O. Box 85500, 3508 GA, Utrecht, Netherlands
| | - Yothin Rakvongthai
- Chulalongkorn University Biomedical Imaging Group, Department of Radiology, Faculty of Medicine, Chulalongkorn University, Bangkok, Thailand
- Division of Nuclear Medicine, Department of Radiology, Faculty of Medicine, Chulalongkorn University, Bangkok, Thailand
| | - Martijn M A Dietze
- Radiology and Nuclear Medicine, Utrecht University and University Medical Center Utrecht, P.O. Box 85500, 3508 GA, Utrecht, Netherlands
| |
Collapse
|
7
|
Kim TP, Gandhi RT, Tolakanahalli R, Herrera R, Chuong MD, Gutierrez AN, Alvarez D. Establishing Updated Safety Standards for Independent 99mTc-MAA SPECT/CT Treatment Planning in Radioembolization. Int J Radiat Oncol Biol Phys 2024; 119:1285-1296. [PMID: 38925768 DOI: 10.1016/j.ijrobp.2023.12.049] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/10/2023] [Revised: 12/08/2023] [Accepted: 12/30/2023] [Indexed: 06/28/2024]
Abstract
PURPOSE Significant improvements within radioembolization imaging and dosimetry permit the development of an accurate and personalized pretreatment plan using technetium 99m-labeled macroaggregated albumin (99mTc-MAA) and single-photon emission computed tomography (SPECT) combined with anatomical CT (SPECT/CT). Despite these potential advantages, the clinical transition to pretreatment protocols with SPECT/CT is hindered by their unknown safety constraints. This study aimed to address this issue by establishing novel dose limits for 99mTc-MAA SPECT/CT to enable quantitative pretreatment planning. METHODS AND MATERIALS Stratification criteria to determine images most viable for dosimetry analysis were created from a cohort of 85 patients. SPECT/CT, cone beam CT, and activity calculations derived from the local deposition method were used to create an accurate pretreatment protocol. Planar and SPECT/CT images were compared using linear regression and modified Bland-Altman analyses to convert accepted planar dose limits to SPECT/CT. To validate these new dose limits, activity calculations based on SPECT/CT were compared with those calculated with the body surface area and planar methods for three treatment plans. RESULTS A total of 38 of 85 patients were deemed viable for dosimetry analysis. SPECT yielded greater lung shunt fractions (LSFs) than planar imaging when LSFs were <4.89%, whereas SPECT yielded lower LSFs than planar imaging when LSFs were >4.89%. Planar to SPECT/CT dose conversions were 0.76×, 0.70×, and 0.55× for the whole liver, normal liver, and lungs, respectively. Patients with SPECT LSFs ≤4.89% were safely treated with the direct application of planar lung dose limits. Activity calculations with the newly established SPECT/CT dose limits were greater than those of the body surface area method by a median range of 33.1% to 61.9% and were lower than planar-based activity calculations by a median range of 12.5% to 13.7% for the whole liver and by 29.4% to 32.2% for the normal liver. CONCLUSIONS This study demonstrated a safe method for translating dose limits from 99mTc-MAA planar imaging to SPECT/CT. A robust pretreatment protocol was further developed guided by the current knowledge in the field. Established SPECT/CT dose limits safely treated 97.5% of patients and permitted the application of independent pretreatment planning with 99mTc-MAA SPECT/CT.
Collapse
Affiliation(s)
| | - Ripal T Gandhi
- Radiation Oncology Department, Miami Cancer Institute, Miami, Florida; Interventional Radiology Department, Miami Cardiac and Vascular Institute, Miami, Florida
| | | | - Robert Herrera
- Radiation Oncology Department, Miami Cancer Institute, Miami, Florida
| | - Michael D Chuong
- Radiation Oncology Department, Miami Cancer Institute, Miami, Florida
| | | | - Diane Alvarez
- Radiation Oncology Department, Miami Cancer Institute, Miami, Florida
| |
Collapse
|
8
|
Ramdhani K, Lam MGEH, Braat AJAT, Smits MLJ, El-Haddad G. Hepatic Radioembolization: A Multistep Theragnostic Procedure. PET Clin 2024; 19:431-446. [PMID: 38816137 DOI: 10.1016/j.cpet.2024.03.010] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 06/01/2024]
Abstract
This article provides a thorough overview of the practice and multistep approach of hepatic radioembolization. The current literature on hepatic radioembolization in primary or metastatic liver tumors as well as future perspectives are discussed.
Collapse
Affiliation(s)
- K Ramdhani
- Department of Radiology and Nuclear Medicine, University Medical Center Utrecht, P.O. Box 85500, 3508 GA Utrecht, The Netherlands.
| | - Marnix G E H Lam
- Department of Radiology and Nuclear Medicine, University Medical Center Utrecht, P.O. Box 85500, 3508 GA Utrecht, The Netherlands
| | - Arthur J A T Braat
- Department of Radiology and Nuclear Medicine, University Medical Center Utrecht, P.O. Box 85500, 3508 GA Utrecht, The Netherlands
| | - Maarten L J Smits
- Department of Radiology and Nuclear Medicine, University Medical Center Utrecht, P.O. Box 85500, 3508 GA Utrecht, The Netherlands
| | - Ghassan El-Haddad
- Diagnostic Imaging and Interventional Radiology, H. Lee Moffitt Cancer Center, FL, USA
| |
Collapse
|
9
|
Cutrì E, Morel-Corlu E, Rolland Y, Saint-Jalmes H, Eliat PA, Garin E, Bezy-Wendling J. A microscopic model of the dose distribution in hepatocellular carcinoma after selective internal radiation therapy. Phys Med 2024; 122:103384. [PMID: 38824827 DOI: 10.1016/j.ejmp.2024.103384] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 10/12/2023] [Revised: 04/03/2024] [Accepted: 05/21/2024] [Indexed: 06/04/2024] Open
Abstract
The dosimetry evaluation for the selective internal radiation therapy is currently performed assuming a uniform activity distribution, which is in contrast with literature findings. A 2D microscopic model of the perfused liver was developed to evaluate the effect of two different 90Y microspheres distributions: i) homogeneous partitioning with the microspheres equally distributed in the perfused liver, and ii) tumor-clustered partitioning where the microspheres distribution is inferred from the patient specific images. METHODS Two subjects diagnosed with liver cancer were included in this study. For each subject, abdominal CT scans acquired prior to the SIRT and post-treatment 90Y positron emission tomography were considered. Two microspheres partitionings were simulated namely homogeneous and tumor-clustered partitioning. The homogeneous and tumor-clustered partitionings were derived starting from CT images. The microspheres radiation is simulated by means of Russell's law. RESULTS In homogenous simulations, the dose delivery is uniform in the whole liver while in the tumor-clustered simulations a heterogeneous distribution of the delivered dose is visible with higher values in the tumor regions. In addition, in the tumor-clustered simulation, the delivered dose is higher in the viable tumor than in the necrotic tumor, for all patients. In the tumor-clustered case, the dose delivered in the non-tumoral tissue (NTT) was considerably lower than in the perfused liver. CONCLUSIONS The model proposed here represents a proof-of-concept for personalized dosimetry assessment based on preoperative CT images.
Collapse
Affiliation(s)
- Elena Cutrì
- Univ Rennes, CLCC Eugène Marquis, Inserm, LTSI - UMR 1099, F-35000, Rennes, France; Université de technologie de Compiègne, CNRS, Biomechanics and Bioengineering, 60203 Compiègne Cedex, France; Inria, Saclay Ile-de-France, Palaiseau, 91120, France.
| | - Ewan Morel-Corlu
- Univ Rennes, CLCC Eugène Marquis, Inserm, LTSI - UMR 1099, F-35000, Rennes, France
| | - Yan Rolland
- Univ Rennes, CLCC Eugène Marquis, Inserm, LTSI - UMR 1099, F-35000, Rennes, France
| | - Hervé Saint-Jalmes
- Univ Rennes, CLCC Eugène Marquis, Inserm, LTSI - UMR 1099, F-35000, Rennes, France
| | - Pierre-Antoine Eliat
- INRAE, INSERM, Univ Rennes, Nutrition Metabolisms and Cancer, NuMeCan, St Gilles, Rennes, France; CNRS, INSERM, Biosit UAR 3480 US_S 018, PRISM, Univ Rennes, Rennes, France
| | - Etienne Garin
- INRAE, INSERM, Univ Rennes, Nutrition Metabolisms and Cancer, NuMeCan, St Gilles, Rennes, France; Department of Nuclear Medicine, Centre Eugène Marquis, Rennes, France
| | | |
Collapse
|
10
|
Kim TP, Enger SA. Characterizing the voxel-based approaches in radioembolization dosimetry with reDoseMC. Med Phys 2024; 51:4007-4027. [PMID: 38703394 DOI: 10.1002/mp.17054] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/15/2022] [Revised: 02/15/2024] [Accepted: 02/20/2024] [Indexed: 05/06/2024] Open
Abstract
BACKGROUND Yttrium-90 (90 Y $^{90}{\rm {Y}}$ ) represents the primary radioisotope used in radioembolization procedures, while holmium-166 (166 Ho $^{166}{\rm {Ho}}$ ) is hypothesized to serve as a viable substitute for90 Y $^{90}{\rm {Y}}$ due to its comparable therapeutic potential and improved quantitative imaging. Voxel-based dosimetry for these radioisotopes relies on activity images obtained through PET or SPECT and dosimetry methods, including the voxel S-value (VSV) and the local deposition method (LDM). However, the evaluation of the accuracy of absorbed dose calculations has been limited by the use of non-ideal reference standards and investigations restricted to the liver. The objective of this study was to expand upon these dosimetry characterizations by investigating the impact of image resolutions, voxel sizes, target volumes, and tissue materials on the accuracy of90 Y $^{90}{\rm {Y}}$ and166 Ho $^{166}{\rm {Ho}}$ dosimetry techniques. METHODS A specialized radiopharmaceutical dosimetry software called reDoseMC was developed using the Geant4 Monte Carlo toolkit and validated by benchmarking the generated90 Y $^{90}{\rm {Y}}$ kernels with published data. The decay spectra of both90 Y $^{90}{\rm {Y}}$ and166 Ho $^{166}{\rm {Ho}}$ were also compared. Multiple VSV kernels were generated for the liver, lungs, soft tissue, and bone for isotropic voxel sizes of 1 mm, 2 mm, and 4 mm. Three theoretical phantom setups were created with 20 or 40 mm activity and mass density inserts for the same three voxel sizes. To replicate the limited spatial resolutions present in PET and SPECT images, image resolutions were modeled using a 3D Gaussian kernel with a Full Width at Half Maximum (FWHM) ranging from 0 to 16 mm and with no added noise. The VSV and LDM dosimetry methods were evaluated by characterizing their respective kernels and analyzing their absorbed dose estimates calculated on theoretical phantoms. The ground truth for these estimations was calculated using reDoseMC. RESULTS The decay spectra obtained through reDoseMC showed less than a 1% difference when compared to previously published experimental data for energies below 1.9 MeV in the case of90 Y $^{90}{\rm {Y}}$ and less than 1% for energies below 1.5 MeV for166 Ho $^{166}{\rm {Ho}}$ . Additionally, the validation kernels for90 Y $^{90}{\rm {Y}}$ VSV exhibited results similar to those found in published Monte Carlo codes, with source dose depositions having less than a 3% error margin. Resolution thresholds (FWHM thresh s ${\rm {FWHM}}_\mathrm{thresh}{\rm {s}}$ ), defined as resolutions that resulted in similar dose estimates between the LDM and VSV methods, were observed for90 Y $^{90}{\rm {Y}}$ . They were 1.5 mm for bone, 2.5 mm for soft tissue and liver, and 8.5 mm for lungs. For166 Ho $^{166}{\rm {Ho}}$ , the accuracy of absorbed dose deposition was found to be dependent on the contributions of absorbed dose from photons. Volume errors due to variations in voxel size impacted the final dose estimates. Larger target volumes yielded more accurate mean doses than smaller volumes. For both radioisotopes, the radial dose profiles for the VSV and LDM approximated but never matched the reference standard. CONCLUSIONS reDoseMC was developed and validated for radiopharmaceutical dosimetry. The accuracy of voxel-based dosimetry was found to vary widely with changes in image resolutions, voxel sizes, chosen target volumes, and tissue material; hence, the standardization of dosimetry protocols was found to be of great importance for comparable dosimetry analysis.
Collapse
Affiliation(s)
- Taehyung Peter Kim
- Medical Physics Unit, Department of Oncology, McGill University, Montreal, Québec, Canada
- Lady Davis Institute for Medical Research, Jewish General Hospital, Montréal, Québec, Canada
| | - Shirin A Enger
- Medical Physics Unit, Department of Oncology, McGill University, Montreal, Québec, Canada
- Lady Davis Institute for Medical Research, Jewish General Hospital, Montréal, Québec, Canada
| |
Collapse
|
11
|
Braat MN, Braat AJ, Lam MG. Toxicity comparison of yttrium-90 resin and glass microspheres radioembolization. THE QUARTERLY JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING : OFFICIAL PUBLICATION OF THE ITALIAN ASSOCIATION OF NUCLEAR MEDICINE (AIMN) [AND] THE INTERNATIONAL ASSOCIATION OF RADIOPHARMACOLOGY (IAR), [AND] SECTION OF THE SOCIETY OF... 2024; 68:133-142. [PMID: 35762664 DOI: 10.23736/s1824-4785.22.03452-5] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/15/2023]
Abstract
BACKGROUND To investigate the clinical, hematological and biochemical toxicity differences between glass and resin yttrium-90 (90Y)-microspheres radioembolization treatment of primary and metastatic liver disease. METHODS Between May 2014 and November 2016 all consecutive glass and resin 90Y microspheres radioembolization treatments were retrospectively analyzed. Biochemical, hematological and clinical data were collected at treatment day, two weeks, one month and three months follow-up. Post-treatment 90Y PET/CTs were assessed for the absorbed doses in non-tumorous liver volume (DNTLV) and tumor volume (DTV). Biochemical, hematological and clinical toxicity were compared between glass and resin using chi square tests and repeated ANOVA measures. Biochemical and clinical toxicity was correlated with DNTLV,total by means of Pearson correlation and independent t-tests. RESULTS A total of 85 patients were included (N.=44 glass, N.=41 resin). Clinical toxicity the day after treatment (i.e. abdominal pain [P=0.000], nausea [P=0.000] and vomiting [P=0.003]) was more prevalent for resin. Biochemical and hematological toxicities were similar for both microspheres. The DNTLV,total was significantly higher in patients with REILD grade ≥3 in the resin group (43.5 versus 33.3 Gy [P=0.050]). A similar non-significant trend was seen in the glass group: 95.0 versus 69.0 Gy [P=0.144]. CONCLUSIONS The clinical, hematological and biochemical toxicity of radioembolization treatment with glass and resin is comparable, however, post-embolization syndrome related complaints are more common for resin.
Collapse
Affiliation(s)
- Manon N Braat
- Department of Radiology and Nuclear Medicine, University Medical Center Utrecht, Utrecht, the Netherlands -
| | - Arthur J Braat
- Department of Radiology and Nuclear Medicine, University Medical Center Utrecht, Utrecht, the Netherlands
| | - Marnix G Lam
- Department of Radiology and Nuclear Medicine, University Medical Center Utrecht, Utrecht, the Netherlands
| |
Collapse
|
12
|
Inchingolo R, Cortese F, Pisani AR, Acquafredda F, Calbi R, Memeo R, Anagnostopoulos F, Spiliopoulos S. Selective internal radiation therapy segmentectomy: A new minimally invasive curative option for primary liver malignancies? World J Gastroenterol 2024; 30:2379-2386. [PMID: 38764771 PMCID: PMC11099395 DOI: 10.3748/wjg.v30.i18.2379] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 01/18/2024] [Revised: 03/15/2024] [Accepted: 04/19/2024] [Indexed: 05/11/2024] Open
Abstract
Transarterial radioembolization or selective internal radiation therapy (SIRT) has emerged as a minimally invasive approach for the treatment of tumors. This percutaneous technique involves the local, intra-arterial delivery of radioactive microspheres directly into the tumor. Historically employed as a palliative measure for liver malignancies, SIRT has gained traction over the past decade as a potential curative option, mirroring the increasing role of radiation segmentectomy. The latest update of the BCLC hepatocellular carcinoma guidelines recognizes SIRT as an effective treatment modality comparable to other local ablative methods, particularly well-suited for patients where surgical resection or ablation is not feasible. Radiation segmentectomy is a more selective approach, aiming to deliver high-dose radiation to one to three specific hepatic segments, while minimizing damage to surrounding healthy tissue. Future research efforts in radiation segmentectomy should prioritize optimizing radiation dosimetry and refining the technique for super-selective administration of radiospheres within the designated hepatic segments.
Collapse
Affiliation(s)
- Riccardo Inchingolo
- Unit of Interventional Radiology, “F. Miulli” Regional General Hospital, Bari 70021, Italy
| | - Francesco Cortese
- Unit of Interventional Radiology, “F. Miulli” Regional General Hospital, Bari 70021, Italy
| | - Antonio Rosario Pisani
- Interdisciplinary Department of Medicine, Section of Nuclear Medicine, University of Bari “Aldo Moro”, Bari 70121, Italy
| | - Fabrizio Acquafredda
- Unit of Interventional Radiology, “F. Miulli” Regional General Hospital, Bari 70021, Italy
| | - Roberto Calbi
- Department of Radiology, General Regional Hospital “F. Miulli”, Acquaviva delle Fonti 70021, Italy
| | - Riccardo Memeo
- Unit of Hepato-Pancreatic-Biliary Surgery, “F. Miulli” Regional General Hospital, Bari 70021, Italy
| | - Fotis Anagnostopoulos
- The Second Radiology Department, National and Kapodistrian University of Athens, Chaidari Athens 12461, Greece
| | - Stavros Spiliopoulos
- The Second Radiology Department, National and Kapodistrian University of Athens, Chaidari Athens 12461, Greece
| |
Collapse
|
13
|
Huesa-Berral C, Withrow JD, Dawson RJ, Beekman C, Bolch WE, Paganetti H, Wehrenberg-Klee E, Bertolet A. MIDOS: a novel stochastic model towards a treatment planning system for microsphere dosimetry in liver tumors. Eur J Nucl Med Mol Imaging 2024; 51:1506-1515. [PMID: 38155237 PMCID: PMC11043005 DOI: 10.1007/s00259-023-06567-9] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/24/2023] [Accepted: 12/08/2023] [Indexed: 12/30/2023]
Abstract
PURPOSE Transarterial radioembolization (TARE) procedures treat liver tumors by injecting radioactive microspheres into the hepatic artery. Currently, there is a critical need to optimize TARE towards a personalized dosimetry approach. To this aim, we present a novel microsphere dosimetry (MIDOS) stochastic model to estimate the activity delivered to the tumor(s), normal liver, and lung. METHODS MIDOS incorporates adult male/female liver computational phantoms with the hepatic arterial, hepatic portal venous, and hepatic venous vascular trees. Tumors can be placed in both models at user discretion. The perfusion of microspheres follows cluster patterns, and a Markov chain approach was applied to microsphere navigation, with the terminal location of microspheres determined to be in either normal hepatic parenchyma, hepatic tumor, or lung. A tumor uptake model was implemented to determine if microspheres get lodged in the tumor, and a probability was included in determining the shunt of microspheres to the lung. A sensitivity analysis of the model parameters was performed, and radiation segmentectomy/lobectomy procedures were simulated over a wide range of activity perfused. Then, the impact of using different microspheres, i.e., SIR-Sphere®, TheraSphere®, and QuiremSphere®, on the tumor-to-normal ratio (TNR), lung shunt fraction (LSF), and mean absorbed dose was analyzed. RESULTS Highly vascularized tumors translated into increased TNR. Treatment results (TNR and LSF) were significantly more variable for microspheres with high particle load. In our scenarios with 1.5 GBq perfusion, TNR was maximum for TheraSphere® at calibration time in segmentectomy/lobar technique, for SIR-Sphere® at 1-3 days post-calibration, and regarding QuiremSphere® at 3 days post-calibration. CONCLUSION This novel approach is a decisive step towards developing a personalized dosimetry framework for TARE. MIDOS assists in making clinical decisions in TARE treatment planning by assessing various delivery parameters and simulating different tumor uptakes. MIDOS offers evaluation of treatment outcomes, such as TNR and LSF, and quantitative scenario-specific decisions.
Collapse
Affiliation(s)
- Carlos Huesa-Berral
- Department of Radiation Oncology, Massachusetts General Hospital and Harvard Medical School, Boston, MA, USA.
| | - Julia D Withrow
- J. Crayton Pruitt Family Department of Biomedical Engineering, University of Florida, Gainesville, FL, USA
| | - Robert J Dawson
- J. Crayton Pruitt Family Department of Biomedical Engineering, University of Florida, Gainesville, FL, USA
| | - Chris Beekman
- Department of Radiation Oncology, Massachusetts General Hospital and Harvard Medical School, Boston, MA, USA
| | - Wesley E Bolch
- J. Crayton Pruitt Family Department of Biomedical Engineering, University of Florida, Gainesville, FL, USA
| | - Harald Paganetti
- Department of Radiation Oncology, Massachusetts General Hospital and Harvard Medical School, Boston, MA, USA
| | - Eric Wehrenberg-Klee
- Division of Interventional Radiology, Department of Radiology, Massachusetts General Hospital and Harvard Medical School, Boston, MA, USA
| | - Alejandro Bertolet
- Department of Radiation Oncology, Massachusetts General Hospital and Harvard Medical School, Boston, MA, USA.
| |
Collapse
|
14
|
Wagemans MEHM, Kunnen B, Stella M, van Rooij R, Smits M, Bruijnen R, Lam MGEH, de Jong HWAM, Braat AJAT. Comparison of 3 Different Therapeutic Particles in Radioembolization of Locally Advanced Intrahepatic Cholangiocarcinoma. J Nucl Med 2024; 65:272-278. [PMID: 38176716 DOI: 10.2967/jnumed.123.265597] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/16/2023] [Revised: 11/07/2023] [Indexed: 01/06/2024] Open
Abstract
Our objective was to compare 3 different therapeutic particles used for radioembolization in locally advanced intrahepatic cholangiocarcinoma. Methods: 90Y-glass, 90Y-resin, and 166Ho-labeled poly(l-lactic acid) microsphere prescribed activity was calculated as per manufacturer recommendations. Posttreatment quantitative 90Y PET/CT and quantitative 166Ho SPECT/CT were used to determine tumor-absorbed dose, whole-normal-liver-absorbed dose, treated-normal-liver-absorbed dose, tumor-to-nontumor ratio, lung-absorbed dose, and lung shunt fraction. Response was assessed using RECIST 1.1 and the [18F]FDG PET-based change in total lesion glycolysis. Hepatotoxicity was assessed using the radioembolization-induced liver disease classification. Results: Six 90Y-glass, 8 90Y-resin, and 7 166Ho microsphere patients were included for analysis. The mean administered activity was 2.6 GBq for 90Y-glass, 1.5 GBq for 90Y-resin, and 7.0 GBq for 166Ho microspheres. Tumor-absorbed dose and treated-normal-liver-absorbed dose were significantly higher for 90Y-glass than for 90Y-resin and 166Ho microspheres (mean tumor-absorbed dose, 197 Gy for 90Y-glass vs. 73 Gy for 90Y-resin and 50 Gy for 166Ho; mean treated-normal-liver-absorbed dose, 79 Gy for 90Y-glass vs. 37 Gy for 90Y-resin and 31 Gy for 166Ho). The whole-normal-liver-absorbed dose and tumor-to-nontumor ratio did not significantly differ between the particles. All patients had a lung-absorbed dose under 30 Gy and a lung shunt fraction under 20%. The 3 groups showed similar toxicity and response according to RECIST 1.1 and [18F]FDG PET-based total lesion glycolysis changes. Conclusion: The therapeutic particles used for radioembolization differed from each other and showed significant differences in absorbed dose, whereas toxicity and response were similar for all groups. This finding emphasizes the need for separate dose constraints and dose targets for each particle.
Collapse
Affiliation(s)
- Martijn E H M Wagemans
- Department of Radiology and Nuclear Medicine, UMC Utrecht, Utrecht, The Netherlands; and
| | - Britt Kunnen
- Department of Radiology and Nuclear Medicine, UMC Utrecht, Utrecht, The Netherlands; and
- Image Sciences Institute, UMC Utrecht and University Utrecht, Utrecht, The Netherlands
| | - Martina Stella
- Department of Radiology and Nuclear Medicine, UMC Utrecht, Utrecht, The Netherlands; and
| | - Rob van Rooij
- Department of Radiology and Nuclear Medicine, UMC Utrecht, Utrecht, The Netherlands; and
| | - Maarten Smits
- Department of Radiology and Nuclear Medicine, UMC Utrecht, Utrecht, The Netherlands; and
| | - Rutger Bruijnen
- Department of Radiology and Nuclear Medicine, UMC Utrecht, Utrecht, The Netherlands; and
| | - Marnix G E H Lam
- Department of Radiology and Nuclear Medicine, UMC Utrecht, Utrecht, The Netherlands; and
| | - Hugo W A M de Jong
- Department of Radiology and Nuclear Medicine, UMC Utrecht, Utrecht, The Netherlands; and
| | - Arthur J A T Braat
- Department of Radiology and Nuclear Medicine, UMC Utrecht, Utrecht, The Netherlands; and
| |
Collapse
|
15
|
Villalobos A, Pisanie JLD, Gandhi RT, Kokabi N. Yttrium-90 Radioembolization Dosimetry: Dose Considerations, Optimization, and Tips. Semin Intervent Radiol 2024; 41:63-78. [PMID: 38495257 PMCID: PMC10940044 DOI: 10.1055/s-0044-1779715] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 03/19/2024]
Affiliation(s)
- Alexander Villalobos
- Department of Radiology, University of North Carolina at Chapel Hill, Chapel Hill, North Carolina
| | - Johannes L. du Pisanie
- Department of Radiology, University of North Carolina at Chapel Hill, Chapel Hill, North Carolina
| | - Ripal T. Gandhi
- Department of Radiology, University of North Carolina at Chapel Hill, Chapel Hill, North Carolina
| | - Nima Kokabi
- Department of Radiology, University of North Carolina at Chapel Hill, Chapel Hill, North Carolina
| |
Collapse
|
16
|
Lee JH, Lee CH, Kim M, Song YS, Yoon CJ, Lee WW. CT texture features and lung shunt fraction measured using 99mTc-macroaggregated albumin SPECT/CT before trans-arterial radioembolization for hepatocellular carcinoma patients. Sci Rep 2023; 13:22288. [PMID: 38097801 PMCID: PMC10721865 DOI: 10.1038/s41598-023-49787-7] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/30/2023] [Accepted: 12/12/2023] [Indexed: 12/17/2023] Open
Abstract
The aim of this study is to determine whether contrast-enhanced computed tomography (CECT)-based texture parameters can predict high (> 30 Gy) expected lung dose (ELD) calculated using 99mTc macroaggregated albumin single-photon emission computed tomography/computed tomography (SPECT/CT) for pre-trans-arterial radioembolization (TARE) dosimetry. 35 patients were analyzed, with a treatable planned dose of ≥ 200 Gy for unresectable hepatocellular carcinoma (HCC). Lung shunt fraction (LSF) was obtained from planar and SPECT/CT scans. Texture features of the tumor lesion on CECT before TARE were analyzed. Univariate and multivariate linear regression analyses were performed to determine potential ELD > 30 Gy predictors. Among the 35 patients, nine (25.7%) had ELD > 30 Gy, and had a higher LSF than the ELD ≤ 30 Gy group using the planar (20.7 ± 8.0% vs. 6.3 ± 3.3%; P < 0.001) and SPECT/CT (12.4 ± 5.1% vs. 3.5 ± 2.0%; P < 0.001) scans. The tumor integral total (HU × L) value was a predictor for high LSF using SPECT/CT, with an area under the curve, sensitivity, and specificity of 0.983 (95% confidence interval: 0.869-1.000, P < 0.001), 100%, and 88.5%, respectively. The tumor integral total value is an imaging marker for predicting ELD > 30 Gy. Applying CECT texture analysis may assist in reducing time and cost in patient selection and modifying TARE treatment plans.
Collapse
Affiliation(s)
- Jae Hwan Lee
- Department of Radiology, Seoul National University Bundang Hospital, Bundang-gu, Seongnam-si, Gyeonggi-do, Republic of Korea
- Department of Radiology, Seoul National University College of Medicine, Jongno-gu, Seoul, Republic of Korea
- Institute of Radiation Medicine, Seoul National University Medical Research Center, Jongno-gu, Seoul, Republic of Korea
| | - Chong-Ho Lee
- Department of Radiology, Seoul National University Bundang Hospital, Bundang-gu, Seongnam-si, Gyeonggi-do, Republic of Korea
| | - Minuk Kim
- Department of Radiology, Seoul Metropolitan Government-Seoul National University Boramae Medical Center, Seoul, Korea
| | - Yoo Sung Song
- Department of Nuclear Medicine, Seoul National University Bundang Hospital, Bundang-gu, Seongnam-si, Gyeonggi-do, Republic of Korea.
- Department of Nuclear Medicine, Seoul National University College of Medicine, Seoul, Republic of Korea.
| | - Chang Jin Yoon
- Department of Radiology, Seoul National University Bundang Hospital, Bundang-gu, Seongnam-si, Gyeonggi-do, Republic of Korea
- Department of Radiology, Seoul National University College of Medicine, Jongno-gu, Seoul, Republic of Korea
- Institute of Radiation Medicine, Seoul National University Medical Research Center, Jongno-gu, Seoul, Republic of Korea
| | - Won Woo Lee
- Institute of Radiation Medicine, Seoul National University Medical Research Center, Jongno-gu, Seoul, Republic of Korea
- Department of Nuclear Medicine, Seoul National University Bundang Hospital, Bundang-gu, Seongnam-si, Gyeonggi-do, Republic of Korea
- Department of Nuclear Medicine, Seoul National University College of Medicine, Seoul, Republic of Korea
- Department of Health Science and Technology, The Graduate School of Convergence Science and Technology, Seoul National University, Suwon-si, Gyeonggi-do, Republic of Korea
| |
Collapse
|
17
|
Doyle PW, Workman CS, Shah N, McGonigle TW, Grice JV, Huang S, Borgmann AJ, Baker JC, Guys NP, Taylor JE, Brown DB. Predictive Partition Dosimetry and Outcomes after Yttrium-90 Resin Microsphere Radioembolization of Colorectal Cancer Metastatic to the Liver: A Retrospective Analysis. J Vasc Interv Radiol 2023; 34:2138-2146. [PMID: 37640105 DOI: 10.1016/j.jvir.2023.08.031] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/05/2023] [Revised: 06/26/2023] [Accepted: 08/21/2023] [Indexed: 08/31/2023] Open
Abstract
PURPOSE To characterize estimated absorbed tumor dose (ADT), objective response (OR), and estimated target dose of liver metastatic colorectal cancer (mCRC) after resin microsphere yttrium-90 (90Y) radioembolization using partition dosimetry. MATERIALS AND METHODS In this retrospective, single-center study, multicompartment dosimetry of index tumors undergoing 90Y radioembolization from October 2013 to July 2022 was performed using MIM SurePlan and pretreatment technetium-99m macroaggregated albumin infusion data. Thirty-eight patients with mCRC underwent treatments for 59 index tumors. Patients were imaged every 2-3 months after treatment and then every 3-6 months after disease control to determine the best response per Response Evaluation Criteria in Solid Tumors 1.1. Responses were categorized as OR or nonresponse (NR). A Cox proportional hazards model evaluated the probability of tumor OR and local progression-free survival (LPFS) based on ADT. RESULTS Patients had a median follow-up of 116 days (interquartile range [IQR], 69-231 days). The ADT was higher for OR patients than for NR patients (median, 130.8 [IQR, 85.6-239.0] vs 40.6 [IQR, 26.0-66.3] Gy; P < .001). A greater percentage of OR than NR patients were treated with activities calculated by partition modeling (54% vs 12%; P = .005). Only ADT predicted response (P = .032). At 6 months, an ADT of 120 Gy predicted a 55% (95% CI, 0.0%-89%) probability of OR. Only ADT (P = .010) and female sex (P = .014) predicted LPFS. At 1 year, an ADT of 120 Gy predicted a 70% (95% CI, 35%-100%) probability of LPFS. CONCLUSIONS Tumor dose was the strongest predictor of OR for mCRC. Administration of an estimated 120 Gy to mCRC predicted 55% OR with 90Y resin microspheres at 6 months.
Collapse
Affiliation(s)
- Patrick W Doyle
- Vanderbilt University School of Medicine, Nashville, Tennessee
| | - C Spencer Workman
- Department of Radiology, Vanderbilt University Medical Center, Nashville, Tennessee
| | - Neal Shah
- Department of Radiology, Vanderbilt University Medical Center, Nashville, Tennessee
| | - Trey W McGonigle
- Department of Biostatistics, Vanderbilt University Medical Center, Nashville, Tennessee
| | - Jared V Grice
- Department of Radiology, Vanderbilt University Medical Center, Nashville, Tennessee
| | - Shi Huang
- Department of Biostatistics, Vanderbilt University Medical Center, Nashville, Tennessee
| | - Anthony J Borgmann
- Department of Radiology, Vanderbilt University Medical Center, Nashville, Tennessee
| | - Jennifer C Baker
- Department of Radiology, Vanderbilt University Medical Center, Nashville, Tennessee
| | - Nicholas P Guys
- Department of Radiology, Vanderbilt University Medical Center, Nashville, Tennessee
| | - Jason E Taylor
- Department of Radiology, Vanderbilt University Medical Center, Nashville, Tennessee
| | - Daniel B Brown
- Department of Radiology, Vanderbilt University Medical Center, Nashville, Tennessee.
| |
Collapse
|
18
|
Andel D, Hagendoorn J, Alsultan AA, Lacle MM, Smits MLJ, Braat AJAT, Kranenburg O, Lam MGEH, Borel Rinkes IHM. Colorectal liver metastases that survive radioembolization display features of aggressive tumor behavior. HPB (Oxford) 2023; 25:1345-1353. [PMID: 37442645 DOI: 10.1016/j.hpb.2023.06.011] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 03/03/2023] [Revised: 05/11/2023] [Accepted: 06/20/2023] [Indexed: 07/15/2023]
Abstract
BACKGROUND Radiation lobectomy is a therapeutic approach that involves targeted radiation delivery to induce future liver remnant hypertrophy and tumor control. In patients with colorectal liver metastases, only 30-40% have complete tumor regression. The importance of tumor biology in treatment response remains elusive. METHODS Patients with colorectal liver metastases who received radiation lobectomy were selected from surgical pathology files. Using a machine learning scoring protocol, pathological response was correlated to tumor absorbed dose and expression of markers of radioresistance Ki-67 (proliferation), CAIX (hypoxia), Olfm4 (cancer stem cells) and CD45 (leukocytes). RESULTS No linear association was found between tumor dose and response (ρ < 0.1, P = 0.73 (90Y), P = 0.92 (166Ho)). Response did correlate with proliferation (ρ = 0.56, P = 0.012), and non-responsive lesions had large pools (>15%) of Olfm4 positive cancer stem cells (Fisher's exact test, P = 0.0037). Responding lesions (regression grade ≤2) were highly hypoxic compared to moderate and non-responding lesions (P = 0.011). Non-responsive lesions had more tumor-infiltrating leukocytes (3240 cells/mm2 versus 650 cells/mm2), although this difference was not significant (P = 0.08). CONCLUSION The aggressive phenotype of a subset of surviving cancer cells emphasizes the importance of prompt resection after radiation lobectomy.
Collapse
Affiliation(s)
- Daan Andel
- Department of Surgical Oncology, University Medical Center Utrecht, Cancer Center, Utrecht, the Netherlands.
| | - Jeroen Hagendoorn
- Department of Surgical Oncology, University Medical Center Utrecht, Cancer Center, Utrecht, the Netherlands
| | - Ahmed Aziz Alsultan
- Department of Radiology and Nuclear Medicine, University Medical Center Utrecht, Cancer Center, Utrecht, the Netherlands
| | - Miangela Marie Lacle
- Department of Pathology, University Medical Center Utrecht, Utrecht University, Utrecht, the Netherlands
| | - Maarten Leonard Johannes Smits
- Department of Radiology and Nuclear Medicine, University Medical Center Utrecht, Cancer Center, Utrecht, the Netherlands
| | | | - Onno Kranenburg
- Department of Surgical Oncology, University Medical Center Utrecht, Cancer Center, Utrecht, the Netherlands
| | | | | |
Collapse
|
19
|
Andel D, Lam MGEH, de Bruijne J, Smits MLJ, Braat AJAT, Moelker A, Vegt E, Ruiter SJS, Noordzij W, Grazi G, Vallati GE, Bennink RJ, van Delden OM, Kranenburg OW, Ijzermans JNM, Nijkamp MW, Erdmann JI, Sciuto R, Hagendoorn J, Borel Rinkes IHM. Dose finding study for unilobar radioembolization using holmium-166 microspheres to improve resectability in patients with HCC: the RALLY protocol. BMC Cancer 2023; 23:771. [PMID: 37596578 PMCID: PMC10436405 DOI: 10.1186/s12885-023-11280-9] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/26/2022] [Accepted: 08/08/2023] [Indexed: 08/20/2023] Open
Abstract
BACKGROUND High dose unilobar radioembolization (also termed 'radiation lobectomy')-the transarterial unilobar infusion of radioactive microspheres as a means of controlling tumour growth while concomitantly inducing future liver remnant hypertrophy-has recently gained interest as induction strategy for surgical resection. Prospective studies on the safety and efficacy of the unilobar radioembolization-surgery treatment algorithm are lacking. The RALLY study aims to assess the safety and toxicity profile of holmium-166 unilobar radioembolization in patients with hepatocellular carcinoma ineligible for surgery due to insufficiency of the future liver remnant. METHODS The RALLY study is a multicenter, interventional, non-randomized, open-label, non-comparative safety study. Patients with hepatocellular carcinoma who are considered ineligible for surgery due to insufficiency of the future liver remnant (< 2.7%/min/m2 on hepatobiliary iminodiacetic acid scan will be included. A classical 3 + 3 dose escalation model will be used, enrolling three to six patients in each cohort. The primary objective is to determine the maximum tolerated treated non-tumourous liver-absorbed dose (cohorts of 50, 60, 70 and 80 Gy). Secondary objectives are to evaluate dose-response relationships, to establish the safety and feasibility of surgical resection following unilobar radioembolization, to assess quality of life, and to generate a biobank. DISCUSSION This will be the first clinical study to assess the unilobar radioembolization-surgery treatment algorithm and may serve as a stepping stone towards its implementation in routine clinical practice. TRIAL REGISTRATION Netherlands Trial Register NL8902 , registered on 2020-09-15.
Collapse
Affiliation(s)
- Daan Andel
- Department of Surgical Oncology, University Medical Center Utrecht, Cancer Center, PO BOX 85500, 3508 GA, Utrecht, The Netherlands.
| | - Marnix G E H Lam
- Department of Radiology and Nuclear Medicine, University Medical Center Utrecht, Cancer Center, Utrecht, The Netherlands
| | - Joep de Bruijne
- Department Gastroenterology and Hepatology, University Medical Center Utrecht, Utrecht, the Netherlands
| | - Maarten L J Smits
- Department of Radiology and Nuclear Medicine, University Medical Center Utrecht, Cancer Center, Utrecht, The Netherlands
| | - Arthur J A T Braat
- Department of Radiology and Nuclear Medicine, University Medical Center Utrecht, Cancer Center, Utrecht, The Netherlands
| | - Adriaan Moelker
- Department of Radiology and Nuclear Medicine, Erasmus MC University Medical Center, Rotterdam, The Netherlands
| | - Erik Vegt
- Department of Radiology and Nuclear Medicine, Erasmus MC University Medical Center, Rotterdam, The Netherlands
| | - Simeon J S Ruiter
- Department of HPB & Liver Transplantation, University Medical Center Groningen, Groningen, The Netherlands
| | - Walter Noordzij
- Department of Nuclear Medicine and Molecular Imaging, University Medical Center Groningen, Groningen, The Netherlands
| | - Gianluca Grazi
- Hepatopancreatobiliary Surgery, IRCCS - Regina Elena National Cancer Institute, Rome, Italy
| | - Giulio E Vallati
- Interventional Radiology, IRCCS - Regina Elena National Cancer Institute, Rome, Italy
| | - Roel J Bennink
- Department of Radiology and Nuclear Medicine, Cancer Center, Amsterdam UMC, Location University of Amsterdam, Amsterdam, The Netherlands
| | - Otto M van Delden
- Department of Radiology and Nuclear Medicine, Cancer Center, Amsterdam UMC, Location University of Amsterdam, Amsterdam, The Netherlands
| | - Onno W Kranenburg
- Department of Surgical Oncology, University Medical Center Utrecht, Cancer Center, PO BOX 85500, 3508 GA, Utrecht, The Netherlands
| | - Jan N M Ijzermans
- Department of Surgery, Erasmus MC University Medical Center, Rotterdam, The Netherlands
| | - Maarten W Nijkamp
- Department of HPB & Liver Transplantation, University Medical Center Groningen, Groningen, The Netherlands
| | - Joris I Erdmann
- Department of Surgery, Cancer Center, Amsterdam UMC, Location Vrije Universiteit Amsterdam, Amsterdam, The Netherlands
| | - Rosa Sciuto
- Nuclear Medicine, IRCCS - Regina Elena National Cancer Institute, Rome, Italy
| | - Jeroen Hagendoorn
- Department of Surgical Oncology, University Medical Center Utrecht, Cancer Center, PO BOX 85500, 3508 GA, Utrecht, The Netherlands
| | - Inne H M Borel Rinkes
- Department of Surgical Oncology, University Medical Center Utrecht, Cancer Center, PO BOX 85500, 3508 GA, Utrecht, The Netherlands.
| |
Collapse
|
20
|
Stella M, van Rooij R, Lam MGEH, de Jong HWAM, Braat AJAT. Automatic healthy liver segmentation for holmium-166 radioembolization dosimetry. EJNMMI Res 2023; 13:68. [PMID: 37453996 DOI: 10.1186/s13550-023-00996-1] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/24/2023] [Accepted: 05/08/2023] [Indexed: 07/18/2023] Open
Abstract
BACKGROUND For safe and effective holmium-166 (166Ho) liver radioembolization, dosimetry is crucial and requires accurate healthy liver definition. The current clinical standard relies on manual segmentation and registration of a separately acquired contrast enhanced CT (CECT), a prone-to-error and time-consuming task. An alternative is offered by simultaneous imaging of 166Ho and technetium-99m stannous-phytate accumulating in healthy liver cells (166Ho-99mTc dual-isotope protocol). This study compares healthy liver segmentation performed with an automatic method using 99mTc images derived from a 166Ho-99mTc dual-isotope acquisition to the manual segmentation, focusing on healthy liver dosimetry and corresponding hepatotoxicity. Data from the prospective HEPAR PLuS study were used. Automatic healthy liver segmentation was obtained by thresholding the 99mTc image (no registration step required). Manual segmentation was performed on CECT and then manually registered to the SPECT/CT and subsequently to the corresponding 166Ho SPECT to compute absorbed dose in healthy liver. RESULTS Thirty-one patients (66 procedures) were assessed. Manual segmentation and registration took a median of 30 min per patient, while automatic segmentation was instantaneous. Mean ± standard deviation of healthy liver absorbed dose was 18 ± 7 Gy and 20 ± 8 Gy for manual and automatic segmentations, respectively. Mean difference ± coefficient of reproducibility between healthy liver absorbed doses using the automatic versus manual segmentation was 2 ± 6 Gy. No correlation was found between mean absorbed dose in the healthy liver and hepatotoxicity. CONCLUSIONS 166Ho-99mTc dual-isotope protocol can automatically segment the healthy liver without hampering the 166Ho dosimetry assessment. TRIAL REGISTRATION ClinicalTrials.gov, NCT02067988. Registered 20 February 2014. https://clinicaltrials.gov/ct2/show/NCT02067988.
Collapse
Affiliation(s)
- Martina Stella
- Department of Radiology and Nuclear Medicine, UMC Utrecht, Heidelberglaan 100, 3584 CX, Utrecht, The Netherlands.
| | - Rob van Rooij
- Department of Radiology and Nuclear Medicine, UMC Utrecht, Heidelberglaan 100, 3584 CX, Utrecht, The Netherlands
| | - Marnix G E H Lam
- Department of Radiology and Nuclear Medicine, UMC Utrecht, Heidelberglaan 100, 3584 CX, Utrecht, The Netherlands
| | - Hugo W A M de Jong
- Department of Radiology and Nuclear Medicine, UMC Utrecht, Heidelberglaan 100, 3584 CX, Utrecht, The Netherlands
| | - Arthur J A T Braat
- Department of Radiology and Nuclear Medicine, UMC Utrecht, Heidelberglaan 100, 3584 CX, Utrecht, The Netherlands
| |
Collapse
|
21
|
Riveira-Martin M, Akhavanallaf A, Mansouri Z, Bianchetto Wolf N, Salimi Y, Ricoeur A, Mainta I, Garibotto V, López Medina A, Zaidi H. Predictive value of 99mTc-MAA-based dosimetry in personalized 90Y-SIRT planning for liver malignancies. EJNMMI Res 2023; 13:63. [PMID: 37395912 DOI: 10.1186/s13550-023-01011-3] [Citation(s) in RCA: 6] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/09/2023] [Accepted: 06/16/2023] [Indexed: 07/04/2023] Open
Abstract
BACKGROUND Selective internal radiation therapy with 90Y radioembolization aims to selectively irradiate liver tumours by administering radioactive microspheres under the theragnostic assumption that the pre-therapy injection of 99mTc labelled macroaggregated albumin (99mTc-MAA) provides an estimation of the 90Y microspheres biodistribution, which is not always the case. Due to the growing interest in theragnostic dosimetry for personalized radionuclide therapy, a robust relationship between the delivered and pre-treatment radiation absorbed doses is required. In this work, we aim to investigate the predictive value of absorbed dose metrics calculated from 99mTc-MAA (simulation) compared to those obtained from 90Y post-therapy SPECT/CT. RESULTS A total of 79 patients were analysed. Pre- and post-therapy 3D-voxel dosimetry was calculated on 99mTc-MAA and 90Y SPECT/CT, respectively, based on Local Deposition Method. Mean absorbed dose, tumour-to-normal ratio, and absorbed dose distribution in terms of dose-volume histogram (DVH) metrics were obtained and compared for each volume of interest (VOI). Mann-Whitney U-test and Pearson's correlation coefficient were used to assess the correlation between both methods. The effect of the tumoral liver volume on the absorbed dose metrics was also investigated. Strong correlation was found between simulation and therapy mean absorbed doses for all VOIs, although simulation tended to overestimate tumour absorbed doses by 26%. DVH metrics showed good correlation too, but significant differences were found for several metrics, mostly on non-tumoral liver. It was observed that the tumoral liver volume does not significantly affect the differences between simulation and therapy absorbed dose metrics. CONCLUSION This study supports the strong correlation between absorbed dose metrics from simulation and therapy dosimetry based on 90Y SPECT/CT, highlighting the predictive ability of 99mTc-MAA, not only in terms of mean absorbed dose but also of the dose distribution.
Collapse
Affiliation(s)
- Mercedes Riveira-Martin
- Genetic Oncology, Radiobiology and Radiointeraction Research Group, Galicia Sur Health Research Institute, Vigo, Spain
- Department of Radiology, Rehabilitation and Physiotherapy, Medicine School, Complutense University of Madrid, Madrid, Spain
| | - Azadeh Akhavanallaf
- Division of Nuclear Medicine and Molecular Imaging, Diagnostic Department, Geneva University Hospital, 1211, Geneva, Switzerland
| | - Zahra Mansouri
- Division of Nuclear Medicine and Molecular Imaging, Diagnostic Department, Geneva University Hospital, 1211, Geneva, Switzerland
| | - Nicola Bianchetto Wolf
- Division of Nuclear Medicine and Molecular Imaging, Diagnostic Department, Geneva University Hospital, 1211, Geneva, Switzerland
| | - Yazdan Salimi
- Division of Nuclear Medicine and Molecular Imaging, Diagnostic Department, Geneva University Hospital, 1211, Geneva, Switzerland
| | - Alexis Ricoeur
- Service of Radiology, Geneva University Hospital, 1211, Geneva, Switzerland
| | - Ismini Mainta
- Division of Nuclear Medicine and Molecular Imaging, Diagnostic Department, Geneva University Hospital, 1211, Geneva, Switzerland
| | - Valentina Garibotto
- Division of Nuclear Medicine and Molecular Imaging, Diagnostic Department, Geneva University Hospital, 1211, Geneva, Switzerland
- Centre for Biomedical Imaging (CIBM), Geneva, Switzerland
- Geneva Neuroscience Centre, Geneva University, Geneva, Switzerland
| | - Antonio López Medina
- Department of Medical Physics and RP, Hospital do Meixoeiro (GALARIA), Vigo, Spain.
| | - Habib Zaidi
- Division of Nuclear Medicine and Molecular Imaging, Diagnostic Department, Geneva University Hospital, 1211, Geneva, Switzerland.
- Geneva Neuroscience Centre, Geneva University, Geneva, Switzerland.
- Department of Nuclear Medicine and Molecular Imaging, University Medical Centre Groningen, University of Groningen, Groningen, Netherlands.
- Department of Nuclear Medicine, University of Southern Denmark, Odense, Denmark.
| |
Collapse
|
22
|
Patel MV, McNiel D, Brunson C, Kuo PH, Hennemeyer CT, Woodhead G, McGregor H. Prior ablation and progression of disease correlate with higher tumor-to-normal liver 99mTc-MAA uptake ratio in hepatocellular carcinoma. Abdom Radiol (NY) 2023; 48:752-757. [PMID: 36344658 DOI: 10.1007/s00261-022-03718-8] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/14/2022] [Revised: 10/17/2022] [Accepted: 10/17/2022] [Indexed: 11/09/2022]
Abstract
PURPOSE Factors affecting tumor-to-normal tissue ratio (T:N) have implications for patient selection, dosimetry, and outcomes when considering radioembolization for HCC. This study sought to evaluate patient, disease specific, and technical parameters that predict T:N as measured on planning pre-90Y radioembolization 99mTc-MAA scintigraphy for hepatocellular carcinoma (HCC). METHODS 99mTc-MAA hepatic angiography procedures with SPECT/CT over a 4-year period were reviewed. Data recorded included patient demographics, details of underlying liver disease, tumor size, history of prior treatments for HCC and technical parameters from angiography. Anatomic-based segmentation was performed in 93 cases for measurement of tumor and perfused liver volumes and SPECT counts. T:N were calculated and correlated with collected variables. RESULTS Mean calculated T:N was 2.52. History of prior ablation was significantly correlated with higher T:N (mean 3.39 vs 2.24, p = 0.003). Cases in which mapping was being performed for treatment of disease progression was significantly correlated with higher T:N (mean 3.35 vs 2.14, p = 0.001). Larger tumor size trended toward lower T:N (p = 0.052). CONCLUSION Patients with history of ablation and those undergoing treatment for disease progression have higher T:N and, therefore, could be considered for radioembolization preferentially over alternative treatments.
Collapse
Affiliation(s)
- Mikin V Patel
- Department of Radiology, University of Chicago Medical Center, 5841 S Maryland Ave, MC 2026, Chicago, IL, 60637, USA.
| | - David McNiel
- Department of Medical Imaging, University of Arizona Medical Center, Tucson, AZ, USA
| | - Christopher Brunson
- Department of Medical Imaging, University of Arizona Medical Center, Tucson, AZ, USA
| | - Phillip H Kuo
- Department of Medical Imaging, University of Arizona Medical Center, Tucson, AZ, USA
| | - Charles T Hennemeyer
- Department of Medical Imaging, University of Arizona Medical Center, Tucson, AZ, USA
| | - Gregory Woodhead
- Department of Medical Imaging, University of Arizona Medical Center, Tucson, AZ, USA
| | - Hugh McGregor
- Department of Radiology, University of Washington Medicine, Seattle, WA, USA
| |
Collapse
|
23
|
Maciak M, Konior M, Wawszczak D, Majewska A, Brodaczewska K, Piasecki P, Narloch J, Sady M, Olszewski J, Gajewski Z, Kieda C, Dziel T, Iller E. Physical properties and biological impact of 90Y microspheres prepared by sol-gel method for liver radioembolization. Radiat Phys Chem Oxf Engl 1993 2023. [DOI: 10.1016/j.radphyschem.2022.110506] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/26/2022]
|
24
|
A Theranostic Approach in SIRT: Value of Pre-Therapy Imaging in Treatment Planning. J Clin Med 2022; 11:jcm11237245. [PMID: 36498819 PMCID: PMC9736029 DOI: 10.3390/jcm11237245] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/31/2022] [Revised: 11/24/2022] [Accepted: 12/02/2022] [Indexed: 12/12/2022] Open
Abstract
Selective internal radiation therapy (SIRT) is one of the treatment options for liver tumors. Microspheres labelled with a therapeutic radionuclide (90Y or 166Ho) are injected into the liver artery feeding the tumor(s), usually achieving a high tumor absorbed dose and a high tumor control rate. This treatment adopts a theranostic approach with a mandatory simulation phase, using a surrogate to radioactive microspheres (99mTc-macroaggregated albumin, MAA) or a scout dose of 166Ho microspheres, imaged by SPECT/CT. This pre-therapy imaging aims to evaluate the tumor targeting and detect potential contraindications to SIRT, i.e., digestive extrahepatic uptake or excessive lung shunt. Moreover, the absorbed doses to the tumor(s) and the healthy liver can be estimated and used for planning the therapeutic activity for SIRT optimization. The aim of this review is to evaluate the accuracy of this theranostic approach using pre-therapy imaging for simulating the biodistribution of the microspheres. This review synthesizes the recent publications demonstrating the advantages and limitations of pre-therapy imaging in SIRT, particularly for activity planning.
Collapse
|
25
|
Reinders MT, van Erpecum KJ, Smits ML, Braat AJ, de Bruijne J, Bruijnen R, Sprengers D, de Man RA, Vegt E, IJzermans JN, Moelker A, Lam MG. Safety and Efficacy of 166Ho Radioembolization in Hepatocellular Carcinoma: The HEPAR Primary Study. J Nucl Med 2022; 63:1891-1898. [PMID: 35589409 PMCID: PMC9730925 DOI: 10.2967/jnumed.122.263823] [Citation(s) in RCA: 13] [Impact Index Per Article: 4.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/15/2022] [Revised: 04/18/2022] [Indexed: 01/11/2023] Open
Abstract
The safety and efficacy of 166Ho radioembolization was first determined in the HEPAR and HEPAR II studies, which, however, excluded patients with hepatocellular carcinoma (HCC). The aim of this prospective clinical early phase II study was to establish the toxicity profile of 166Ho radioembolization in patients with measurable, liver-dominant HCC; Barcelona clinic liver cancer stage B or C; a Child-Pugh score of no more than B7; and an Eastern Cooperative Oncology Group performance status of 0-1 without curative treatment options. Methods: The primary endpoint was a rate of unacceptable toxicity defined as grade 3 hyperbilirubinemia (Common Terminology Cancer Adverse Events, version 4.03) in combination with a low albumin or ascites level in the absence of disease progression or treatment-related serious adverse events. Secondary endpoints included overall toxicity, response, survival, change in α-fetoprotein, and quality of life. Thirty-one patients with Barcelona clinic liver cancer stage B (71%) or C (29%) HCC were included, mostly multifocal (87%) or bilobar (55%) disease. Results: Common grade 1 or 2 clinical toxicity included fatigue (71%), back pain (55%), ascites (32%), dyspnea (23%), nausea (23%), and abdominal pain (23%), with no more than 10% grade 3-5 toxicity. Grade 3 laboratory toxicity (>10%) included an aspartate transaminase and γ-glutamyltransferase increase (16%), hyperglycemia (19%), and lymphopenia (29%). Treatment-related unacceptable toxicity occurred in 3 of 31 patients. At 3 mo, 54% of target lesions showed a complete or partial response according to modified RECIST. Median overall survival was 14.9 mo (95% CI, 10.4-24.9 mo). No significant changes in quality of life or pain were observed. Conclusion: The safety of 166Ho radioembolization was confirmed in HCC, with less than 10% unacceptable toxicity. Efficacy data support further evaluation.
Collapse
Affiliation(s)
- Margot T.M. Reinders
- Department of Radiology and Nuclear Medicine, University Medical Centre, Utrecht University, Utrecht, The Netherlands
| | - Karel J. van Erpecum
- Department of Gastroenterology and Hepatology University Medical Centre, Utrecht University, Utrecht, The Netherlands
| | - Maarten L.J. Smits
- Department of Radiology and Nuclear Medicine, University Medical Centre, Utrecht University, Utrecht, The Netherlands
| | - Arthur J.A.T. Braat
- Department of Radiology and Nuclear Medicine, University Medical Centre, Utrecht University, Utrecht, The Netherlands
| | - Joep de Bruijne
- Department of Gastroenterology and Hepatology University Medical Centre, Utrecht University, Utrecht, The Netherlands
| | - Rutger Bruijnen
- Department of Radiology and Nuclear Medicine, University Medical Centre, Utrecht University, Utrecht, The Netherlands
| | - Dave Sprengers
- Department of Gastroenterology and Hepatology, Erasmus MC–University Medical Centre, Rotterdam, The Netherlands
| | - Robert A. de Man
- Department of Gastroenterology and Hepatology, Erasmus MC–University Medical Centre, Rotterdam, The Netherlands
| | - Erik Vegt
- Department of Radiology and Nuclear Medicine, Erasmus MC–University Medical Centre, Rotterdam, The Netherlands; and
| | - Jan N.M. IJzermans
- Department of Surgery, Erasmus MC–University Medical Centre, Rotterdam, The Netherlands
| | - Adriaan Moelker
- Department of Radiology and Nuclear Medicine, Erasmus MC–University Medical Centre, Rotterdam, The Netherlands; and
| | - Marnix G.E.H. Lam
- Department of Radiology and Nuclear Medicine, University Medical Centre, Utrecht University, Utrecht, The Netherlands
| |
Collapse
|
26
|
Stella M, van Rooij R, Lam MGEH, de Jong HWAM, Braat AJAT. Lung Dose Measured on Postradioembolization 90Y PET/CT and Incidence of Radiation Pneumonitis. J Nucl Med 2022; 63:1075-1080. [PMID: 34772794 PMCID: PMC9258566 DOI: 10.2967/jnumed.121.263143] [Citation(s) in RCA: 7] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/01/2021] [Revised: 10/26/2021] [Indexed: 01/03/2023] Open
Abstract
Radiation pneumonitis is a rare but possibly fatal side effect of 90Y radioembolization. It may occur 1-6 mo after therapy, if a significant part of the 90Y microspheres shunts to the lungs. In current clinical practice, a predicted lung dose greater than 30 Gy is considered a criterion to exclude patients from treatment. However, contrasting findings regarding the occurrence of radiation pneumonitis and lung dose were previously reported in the literature. In this study, the relationship between the lung dose and the eventual occurrence of radiation pneumonitis after 90Y radioembolization was investigated. Methods: We retrospectively analyzed 317 90Y liver radioembolization procedures performed during an 8-y period (February 2012 to September 2020). We calculated the predicted lung mean dose (LMD) using 99mTc-MAA planar scintigraphy (LMDMAA) acquired during the planning phase and left LMD (LMDY-90) using the 90Y PET/CT acquired after the treatment. For the lung dose computation, we used the left lung as the representative lung volume, to compensate for scatter from the liver moving in the craniocaudal direction because of breathing and mainly affecting the right lung. Results: In total, 272 patients underwent 90Y procedures, of which 63% were performed with glass microspheres and 37% with resin microspheres. The median injected activity was 1,974 MBq (range, 242-9,538 MBq). The median LMDMAA was 3.5 Gy (range, 0.2-89.0 Gy). For 14 procedures, LMDMAA was more than 30 Gy. Median LMDY-90 was 1 Gy (range, 0.0-22.1 Gy). No patients had an LMDY-90 of more than 30 Gy. Of the 3 patients with an LMDY-90 of more than 12 Gy, 2 patients (one with an LMDY-90 of 22.1 Gy and an LMDMAA of 89 Gy; the other with an LMDY-90 of 17.7 Gy and an LMDMAA of 34.1 Gy) developed radiation pneumonitis and consequently died. The third patient, with an LMDY-90 of 18.4 Gy (LMDMAA, 29.1 Gy), died 2 mo after treatment, before the imaging evaluation, because of progressive disease. Conclusion: The occurrence of radiation pneumonitis as a consequence of a lung shunt after 90Y radioembolization is rare (<1%). No radiation pneumonitis developed in patients with a measured LMDY-90 lower than 12 Gy.
Collapse
Affiliation(s)
- Martina Stella
- Division of Imaging and Oncology, University Medical Center Utrecht, Utrecht University, Utrecht, The Netherlands
| | - Rob van Rooij
- Division of Imaging and Oncology, University Medical Center Utrecht, Utrecht University, Utrecht, The Netherlands
| | - Marnix G E H Lam
- Division of Imaging and Oncology, University Medical Center Utrecht, Utrecht University, Utrecht, The Netherlands
| | - Hugo W A M de Jong
- Division of Imaging and Oncology, University Medical Center Utrecht, Utrecht University, Utrecht, The Netherlands
| | - Arthur J A T Braat
- Division of Imaging and Oncology, University Medical Center Utrecht, Utrecht University, Utrecht, The Netherlands
| |
Collapse
|
27
|
Dietze MMA, de Jong HWAM. Progress in large field-of-view interventional planar scintigraphy and SPECT imaging. Expert Rev Med Devices 2022; 19:393-403. [PMID: 35695477 DOI: 10.1080/17434440.2022.2088355] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/04/2022]
Abstract
INTRODUCTION Handheld gamma cameras and gamma probes have been successfully implemented for enabling nuclear image or radio-guidance in minimally-invasive procedures. There is an opportunity for large field-of-view interventional planar scintigraphy and SPECT imaging to complement these small field-of-view devices for two reasons. First, a large field-of-view camera enables imaging of relatively larger organs and activity accumulations that are not close to the patient's skin. And second, more precise corrections can be implemented in the SPECT reconstruction algorithm, improving its quality. AREAS COVERED This review article discusses the progress that has been made in the field of large field-of-view interventional planar scintigraphy and SPECT imaging. First, an overview of planar scintigraphy and SPECT is provided. Second, an exploration is given of the potential applications where large field-of-view interventional planar scintigraphy and SPECT imaging may be employed. And third, the requirements for scanner hardware are discussed and an overview of the possible system configurations is provided. EXPERT OPINION We believe that there is an opportunity for large field-of-view interventional planar scintigraphy and SPECT imaging to assist clinical workflows. A major effort is now required to evaluate the prototype systems in clinical studies so that valuable practical experience can be obtained.
Collapse
Affiliation(s)
- Martijn M A Dietze
- Radiology and Nuclear Medicine, Utrecht University and University Medical Center, Utrecht, Netherlands
| | - Hugo W A M de Jong
- Radiology and Nuclear Medicine, Utrecht University and University Medical Center, Utrecht, Netherlands
| |
Collapse
|
28
|
Ahmadzadehfar H, Ilhan H, Lam MGEH, Sraieb M, Stegger L. Radioembolization, Principles and indications. Nuklearmedizin 2022; 61:262-272. [PMID: 35354218 DOI: 10.1055/a-1759-4238] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/18/2022]
Abstract
Radioembolization is the selective application of radionuclide-loaded microspheres into liver arteries for the therapy of liver tumours and metastases. In this review, we focused on therapy planning and dosimetry, as well as the main indications of 90Y-glass and resin microspheres and 166Ho-microspheres.
Collapse
Affiliation(s)
| | - Harun Ilhan
- Department of Nuclear Medicine, Klinikum der Universität München, Munich, Germany.,Die Radiologie, Practice for Radiology, Nuclear Medicine, and Radiation Oncology, Munich, Germany
| | - Marnix G E H Lam
- Radiology and Nuclear Medicine, University of Utrecht Faculty of Medicine, Utrecht, Netherlands
| | - Miriam Sraieb
- Nuclear Medicine, University Hospital Essen, Germany
| | - Lars Stegger
- Nuclear Medicine, University Hospital Münster, Germany
| |
Collapse
|
29
|
Stella M, Braat AJAT, Lam MGEH, de Jong HWAM, van Rooij R. 166Holmium- 99mTechnetium dual-isotope imaging: scatter compensation and automatic healthy-liver segmentation for 166Holmium radioembolization dosimetry. EJNMMI Phys 2022; 9:30. [PMID: 35445948 PMCID: PMC9023629 DOI: 10.1186/s40658-022-00459-x] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/20/2021] [Accepted: 04/08/2022] [Indexed: 11/21/2022] Open
Abstract
Background Partition modeling allows personalized activity calculation for holmium-166 (166Ho) radioembolization. However, it requires the definition of tumor and non-tumorous liver, by segmentation and registration of a separately acquired CT, which is time-consuming and prone to error. A protocol including 166Ho-scout, for treatment simulation, and technetium-99m (99mTc) stannous phytate for healthy-liver delineation was proposed. This study assessed the accuracy of automatic healthy-liver segmentation using 99mTc images derived from a phantom experiment. In addition, together with data from a patient study, the effect of different 99mTc activities on the 166Ho-scout images was investigated. To reproduce a typical scout procedure, the liver compartment, including two tumors, of an anthropomorphic phantom was filled with 250 MBq of 166Ho-chloride, with a tumor to non-tumorous liver activity concentration ratio of 10. Eight SPECT/CT scans were acquired, with varying levels of 99mTc added to the non-tumorous liver compartment (ranging from 25 to 126 MBq). For comparison, forty-two scans were performed in presence of only 99mTc from 8 to 240 MBq. 99mTc image quality was assessed by cold-sphere (tumor) contrast recovery coefficients. Automatic healthy-liver segmentation, obtained by thresholding 99mTc images, was evaluated by recovered volume and Sørensen–Dice index. The impact of 99mTc on 166Ho images and the role of the downscatter correction were evaluated on phantom scans and twenty-six patients’ scans by considering the reconstructed 166Ho count density in the healthy-liver. Results All 99mTc image reconstructions were found to be independent of the 166Ho activity present during the acquisition. In addition, cold-sphere contrast recovery coefficients were independent of 99mTc activity. The segmented healthy-liver volume was recovered fully, independent of 99mTc activity as well. The reconstructed 166Ho count density was not influenced by 99mTc activity, as long as an adequate downscatter correction was applied. Conclusion The 99mTc image reconstructions of the phantom scans all performed equally well for the purpose of automatic healthy-liver segmentation, for activities down to 8 MBq. Furthermore, 99mTc could be injected up to at least 126 MBq without compromising 166Ho image quality. Clinical trials The clinical study mentioned is registered with Clinicaltrials.gov (NCT02067988) on February 20, 2014.
Collapse
Affiliation(s)
- Martina Stella
- Department of Radiology and Nuclear Medicine, UMC Utrecht, Heidelberglaan 100, 3584 CX, Utrecht, The Netherlands.
| | - Arthur J A T Braat
- Department of Radiology and Nuclear Medicine, UMC Utrecht, Heidelberglaan 100, 3584 CX, Utrecht, The Netherlands
| | - Marnix G E H Lam
- Department of Radiology and Nuclear Medicine, UMC Utrecht, Heidelberglaan 100, 3584 CX, Utrecht, The Netherlands
| | - Hugo W A M de Jong
- Department of Radiology and Nuclear Medicine, UMC Utrecht, Heidelberglaan 100, 3584 CX, Utrecht, The Netherlands
| | - Rob van Rooij
- Department of Radiology and Nuclear Medicine, UMC Utrecht, Heidelberglaan 100, 3584 CX, Utrecht, The Netherlands
| |
Collapse
|
30
|
d’Abadie P, Walrand S, Lhommel R, Hesse M, Borbath I, Jamar F. Optimization of the Clinical Effectiveness of Radioembolization in Hepatocellular Carcinoma with Dosimetry and Patient-Selection Criteria. Curr Oncol 2022; 29:2422-2434. [PMID: 35448170 PMCID: PMC9024927 DOI: 10.3390/curroncol29040196] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/10/2022] [Revised: 03/26/2022] [Accepted: 03/28/2022] [Indexed: 02/05/2023] Open
Abstract
Selective internal radiation therapy (SIRT) is part of the treatment strategy for hepatocellular carcinoma (HCC). Strong clinical data demonstrated the effectiveness of this therapy in HCC with a significant improvement in patient outcomes. Recent studies demonstrated a strong correlation between the tumor response and the patient outcome when the tumor-absorbed dose was assessed by nuclear medicine imaging. Dosimetry plays a key role in predicting the clinical response and can be optimized using a personalized method of activity planning (multi-compartmental dosimetry). This paper reviews the main clinical results of SIRT in HCC and emphasizes the central role of dosimetry for improving it effectiveness. Moreover, some patient and tumor characteristics predict a worse outcome, and toxicity related to SIRT treatment of advanced HCC patient selection based on the performance status, liver function, tumor characteristics, and tumor targeting using technetium-99m macro-aggregated albumin scintigraphy can significantly improve the clinical performance of SIRT.
Collapse
Affiliation(s)
- Philippe d’Abadie
- Department of Nuclear Medicine, Cliniques Universitaires Saint Luc, Université Catholique de Louvain, 1200 Brussels, Belgium; (S.W.); (R.L.); (M.H.); (F.J.)
- Correspondence: ; Tel.: +32-2764-7944
| | - Stephan Walrand
- Department of Nuclear Medicine, Cliniques Universitaires Saint Luc, Université Catholique de Louvain, 1200 Brussels, Belgium; (S.W.); (R.L.); (M.H.); (F.J.)
| | - Renaud Lhommel
- Department of Nuclear Medicine, Cliniques Universitaires Saint Luc, Université Catholique de Louvain, 1200 Brussels, Belgium; (S.W.); (R.L.); (M.H.); (F.J.)
| | - Michel Hesse
- Department of Nuclear Medicine, Cliniques Universitaires Saint Luc, Université Catholique de Louvain, 1200 Brussels, Belgium; (S.W.); (R.L.); (M.H.); (F.J.)
| | - Ivan Borbath
- Department of Gastroenterology, Cliniques Universitaires Saint Luc, Université Catholique de Louvain, 1200 Brussels, Belgium;
| | - François Jamar
- Department of Nuclear Medicine, Cliniques Universitaires Saint Luc, Université Catholique de Louvain, 1200 Brussels, Belgium; (S.W.); (R.L.); (M.H.); (F.J.)
| |
Collapse
|
31
|
Chan HW, Lo YH, Chang DY, Li JJ, Chang WY, Chen CH, Chang CH, Chen CL, Wang HE, Liu RS, Wu CY. Radiometal-Labeled Chitosan Microspheres as Transarterial Radioembolization Agents against Hepatocellular Carcinoma. Gels 2022; 8:gels8030180. [PMID: 35323293 PMCID: PMC8953182 DOI: 10.3390/gels8030180] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/11/2022] [Revised: 03/09/2022] [Accepted: 03/12/2022] [Indexed: 01/27/2023] Open
Abstract
Transarterial radioembolization (TARE) is an emerging treatment for patients with unresectable hepatocellular carcinoma (HCC). This study successfully developed radiometal-labeled chitosan microspheres (111In/177Lu-DTPA-CMS) with a diameter of 36.5 ± 5.3 μm for TARE. The radiochemical yields of 111In/177Lu-DTPA-CMS were greater than 90% with high radiochemical purities (>98%). Most of the 111In/177Lu-DTPA-CMS were retained in the hepatoma and liver at 1 h after intraarterial (i.a.) administration. Except for liver accumulation, radioactivity in each normal organ was less than 1% of the injected radioactivity (%IA) at 72 h after injection. At 10 days after injection of 177Lu-DTPA-CMS (18.6 ± 1.3 MBq), the size of the hepatoma was significantly reduced by around 81%, while that of the rats in the control group continued to grow. This study demonstrated the effectiveness of 177Lu-DTPA-CMS in the treatment of N1-S1 hepatoma. 111In/177Lu-DTPA-CMS have the potential to be a superior theranostic pair for the treatment of clinical hepatoma.
Collapse
Affiliation(s)
- Hui-Wen Chan
- Department of Biomedical Imaging and Radiological Sciences, National Yang Ming Chiao Tung University, Taipei Branch, Taipei 112, Taiwan; (H.-W.C.); (Y.-H.L.); (D.-Y.C.); (C.-H.C.); (C.-L.C.); (H.-E.W.); (R.-S.L.)
| | - Yi-Hsuan Lo
- Department of Biomedical Imaging and Radiological Sciences, National Yang Ming Chiao Tung University, Taipei Branch, Taipei 112, Taiwan; (H.-W.C.); (Y.-H.L.); (D.-Y.C.); (C.-H.C.); (C.-L.C.); (H.-E.W.); (R.-S.L.)
| | - Deng-Yuan Chang
- Department of Biomedical Imaging and Radiological Sciences, National Yang Ming Chiao Tung University, Taipei Branch, Taipei 112, Taiwan; (H.-W.C.); (Y.-H.L.); (D.-Y.C.); (C.-H.C.); (C.-L.C.); (H.-E.W.); (R.-S.L.)
| | - Jia-Je Li
- KeMyth Biotechnology Corporation, NHRI Incubation Center, National Health Research Institutes, Miaoli 350, Taiwan;
- Division of Infectious Diseases and Tropical Medicine, Department of Internal Medicine, Tri-Service General Hospital, National Defense Medical Center, Taipei 114, Taiwan
| | - Wen-Yi Chang
- Department of Nuclear Medicine, Taipei Veterans General Hospital, Taipei 112, Taiwan; (W.-Y.C.); (C.-H.C.)
| | - Chih-Hao Chen
- Department of Nuclear Medicine, Taipei Veterans General Hospital, Taipei 112, Taiwan; (W.-Y.C.); (C.-H.C.)
| | - Chih-Hsien Chang
- Department of Biomedical Imaging and Radiological Sciences, National Yang Ming Chiao Tung University, Taipei Branch, Taipei 112, Taiwan; (H.-W.C.); (Y.-H.L.); (D.-Y.C.); (C.-H.C.); (C.-L.C.); (H.-E.W.); (R.-S.L.)
- Institute of Nuclear Energy Research, Taoyuan 325, Taiwan
| | - Chuan-Lin Chen
- Department of Biomedical Imaging and Radiological Sciences, National Yang Ming Chiao Tung University, Taipei Branch, Taipei 112, Taiwan; (H.-W.C.); (Y.-H.L.); (D.-Y.C.); (C.-H.C.); (C.-L.C.); (H.-E.W.); (R.-S.L.)
| | - Hsin-Ell Wang
- Department of Biomedical Imaging and Radiological Sciences, National Yang Ming Chiao Tung University, Taipei Branch, Taipei 112, Taiwan; (H.-W.C.); (Y.-H.L.); (D.-Y.C.); (C.-H.C.); (C.-L.C.); (H.-E.W.); (R.-S.L.)
| | - Ren-Shyan Liu
- Department of Biomedical Imaging and Radiological Sciences, National Yang Ming Chiao Tung University, Taipei Branch, Taipei 112, Taiwan; (H.-W.C.); (Y.-H.L.); (D.-Y.C.); (C.-H.C.); (C.-L.C.); (H.-E.W.); (R.-S.L.)
| | - Chun-Yi Wu
- Department of Biomedical Imaging and Radiological Sciences, National Yang Ming Chiao Tung University, Taipei Branch, Taipei 112, Taiwan; (H.-W.C.); (Y.-H.L.); (D.-Y.C.); (C.-H.C.); (C.-L.C.); (H.-E.W.); (R.-S.L.)
- Correspondence:
| |
Collapse
|
32
|
Tang X, Jafargholi Rangraz E, Heeren R, Coudyzer W, Maleux G, Baete K, Verslype C, Gooding MJ, Deroose CM, Nuyts J. Segmentation-guided multi-modal registration of liver images for dose estimation in SIRT. EJNMMI Phys 2022; 9:3. [PMID: 35076801 PMCID: PMC8790002 DOI: 10.1186/s40658-022-00432-8] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/04/2021] [Accepted: 01/12/2022] [Indexed: 12/04/2022] Open
Abstract
Purpose Selective internal radiation therapy (SIRT) requires a good liver registration of multi-modality images to obtain precise dose prediction and measurement. This study investigated the feasibility of liver registration of CT and MR images, guided by segmentation of the liver and its landmarks. The influence of the resulting lesion registration on dose estimation was evaluated. Methods The liver segmentation was done with a convolutional neural network (CNN), and the landmarks were segmented manually. Our image-based registration software and its liver-segmentation-guided extension (CNN-guided) were tuned and evaluated with 49 CT and 26 MR images from 20 SIRT patients. Each liver registration was evaluated by the root mean square distance (RMSD) of mean surface distance between manually delineated liver contours and mass center distance between manually delineated landmarks (lesions, clips, etc.). The root mean square of RMSDs (RRMSD) was used to evaluate all liver registrations. The CNN-guided registration was further extended by incorporating landmark segmentations (CNN&LM-guided) to assess the value of additional landmark guidance. To evaluate the influence of segmentation-guided registration on dose estimation, mean dose and volume percentages receiving at least 70 Gy (V70) estimated on the 99mTc-labeled macro-aggregated albumin (99mTc-MAA) SPECT were computed, either based on lesions from the reference 99mTc-MAA CT (reference lesions) or from the registered floating CT or MR images (registered lesions) using the CNN- or CNN&LM-guided algorithms. Results The RRMSD decreased for the floating CTs and MRs by 1.0 mm (11%) and 3.4 mm (34%) using CNN guidance for the image-based registration and by 2.1 mm (26%) and 1.4 mm (21%) using landmark guidance for the CNN-guided registration. The quartiles for the relative mean dose difference (the V70 difference) between the reference and registered lesions and their correlations [25th, 75th; r] are as follows: [− 5.5% (− 1.3%), 5.6% (3.4%); 0.97 (0.95)] and [− 12.3% (− 2.1%), 14.8% (2.9%); 0.96 (0.97)] for the CNN&LM- and CNN-guided CT to CT registrations, [− 7.7% (− 6.6%), 7.0% (3.1%); 0.97 (0.90)] and [− 15.1% (− 11.3%), 2.4% (2.5%); 0.91 (0.78)] for the CNN&LM- and CNN-guided MR to CT registrations. Conclusion Guidance by CNN liver segmentations and landmarks markedly improves the performance of the image-based registration. The small mean dose change between the reference and registered lesions demonstrates the feasibility of applying the CNN&LM- or CNN-guided registration to volume-level dose prediction. The CNN&LM- and CNN-guided registrations for CTs can be applied to voxel-level dose prediction according to their small V70 change for most lesions. The CNN-guided MR to CT registration still needs to incorporate landmark guidance for smaller change of voxel-level dose estimation.
Collapse
|
33
|
Keane G, Lam M, de Jong H. Beyond the MAA-Y90 Paradigm: The Evolution of Radioembolization Dosimetry Approaches and Scout Particles. Semin Intervent Radiol 2021; 38:542-553. [PMID: 34853500 DOI: 10.1055/s-0041-1736660] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/12/2022]
Abstract
Radioembolization is a well-established treatment for primary and metastatic liver cancer. There is increasing interest in personalized treatment planning supported by dosimetry, as it provides an opportunity to optimize dose delivery to tumor and minimize nontarget deposition, which demonstrably increases the efficacy and safety of this therapy. However, the optimal dosimetry procedure in the radioembolization setting is still evolving; existing data are limited as few trials have prospectively tailored dose based on personalized planning and predominantly semi-empirical methods are used for dose calculation. Since the pretreatment or "scout" procedure forms the basis of dosimetry calculations, an accurate and reliable technique is essential. 99m Tc-MAA SPECT constitutes the current accepted standard for pretreatment imaging; however, inconsistent patterns in published data raise the question whether this is the optimal agent. Alternative particles are now being introduced to the market, and early indications suggest use of an identical scout and treatment particle may be superior to the current standard. This review will undertake an evaluation of the increasingly refined dosimetric methods driving radioembolization practices, and a horizon scanning exercise identifying alternative scout particle solutions. Together these constitute a compelling vision for future treatment planning methods that prioritize individualized care.
Collapse
Affiliation(s)
- Grace Keane
- Nuclear Medicine, Universitair Medisch Centrum Utrecht, Utrecht, The Netherlands
| | - Marnix Lam
- Nuclear Medicine, Universitair Medisch Centrum Utrecht, Utrecht, The Netherlands
| | - Hugo de Jong
- Nuclear Medicine, Universitair Medisch Centrum Utrecht, Utrecht, The Netherlands
| |
Collapse
|
34
|
Yoo MY, Paeng JC, Kim HC, Lee MS, Lee JS, Lee DS, Kang KW, Cheon GJ. Efficacy of voxel-based dosimetry map for predicting response to trans-arterial radioembolization therapy for hepatocellular carcinoma: a pilot study. Nucl Med Commun 2021; 42:1396-1403. [PMID: 34392298 DOI: 10.1097/mnm.0000000000001471] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/04/2023]
Abstract
OBJECTIVE Typical clinical dosimetry models for trans-arterial radioembolization (TARE) assume uniform dose distribution in each tissue compartment. We performed simple voxel-based dosimetry using post-treatment 90Y PET following TARE with 90Y-resin microspheres and investigated its prognostic value in a pilot cohort. METHOD Ten patients with 14 hepatocellular carcinoma lesions who underwent TARE with 90Y-resin microspheres were retrospectively included. The partition model-based expected target tumor dose (TDp) was calculated using a pretreatment 99mTc-macroaggregated albumin scan. From post-treatment 90Y-microsphere PET and voxel-wise S-value kernels, voxel-based dose maps were produced and the absorbed dose of each lesion (TDv) was calculated. Heterogeneity of intratumoral absorbed doses was assessed using the SD and coefficient of variation of voxel doses. The response of each lesion was determined based on contrast-enhanced MRI or CT, or both. Lesion responses were classified as local control success or failure. Prognostic values of dosimetry parameters and clinicopathological factors were evaluated in terms of progression-free survival (PFS) of each lesion. RESULTS TDv was significantly different between local control success and failure groups, whereas tumor size, TDp and intratumoral dose heterogeneity were not. Univariate survival analysis identified serum aspartate transaminase level ≥40 IU/L, tumor size ≥66 mm and TDv <81 Gy as significant prognostic factors for PFS. However, only TDv was an independent predictive factor in the multivariate analysis (P = 0.022). There was a significant correlation between TDv and PFS (P = 0.009; r = 0.669). CONCLUSIONS In TARE, voxel-based dose index TDv can be estimated on post-treatment 90Y PET using a simple method. TDv was a more effective prognostic factor for TARE than TDp and clinicopathologic factors in this pilot study. Further studies are warranted on the role of voxel-based dose and dose distribution in TARE.
Collapse
Affiliation(s)
- Min Young Yoo
- Departments of Nuclear Medicine, Chungbuk National University Hospital, Cheongju
| | - Jin Chul Paeng
- Department of Nuclear Medicine, Seoul National University Hospital
| | - Hyo-Cheol Kim
- Department of Radiology, Seoul National University Hospital
| | - Min Sun Lee
- Department of Nuclear Medicine, Seoul National University Hospital
- Interdisciplinary Program in Radiation Applied Life Science, Seoul National University, Seoul
- Nuclear Emergency and Environmental Protection Division, Korea Atomic Energy Research Institute, Daejeon
| | - Jae Sung Lee
- Department of Nuclear Medicine, Seoul National University Hospital
- Interdisciplinary Program in Radiation Applied Life Science, Seoul National University, Seoul
- Department of Biomedical Sciences, Seoul National University College of Medicine
| | - Dong Soo Lee
- Department of Nuclear Medicine, Seoul National University Hospital
- Department of Molecular Medicine and Biopharmaceutical Sciences, Graduate School of Convergence Science and Technology, Seoul National University, Seoul
| | - Keon Wook Kang
- Department of Nuclear Medicine, Seoul National University Hospital
- Cancer Research Institute, Seoul National University College of Medicine, Seoul, Republic of Korea
| | - Gi Jeong Cheon
- Department of Nuclear Medicine, Seoul National University Hospital
- Cancer Research Institute, Seoul National University College of Medicine, Seoul, Republic of Korea
| |
Collapse
|
35
|
Zijlema SE, Branderhorst W, Bastiaannet R, Tijssen RHN, Lagendijk JJW, van den Berg CAT. Minimizing the need for coil attenuation correction in integrated PET/MRI at 1.5 T using low-density MR-linac receive arrays. Phys Med Biol 2021; 66. [PMID: 34571496 DOI: 10.1088/1361-6560/ac2a8a] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/28/2021] [Accepted: 09/27/2021] [Indexed: 11/12/2022]
Abstract
The simultaneous use of positron emission tomography (PET) and magnetic resonance imaging (MRI) requires attenuation correction (AC) of photon-attenuating objects, such as MRI receive arrays. However, AC of flexible, on-body arrays is complex and therefore often omitted. This can lead to significant, spatially varying PET signal losses when conventional MRI receive arrays are used. Only few dedicated, photon transparent PET/MRI arrays exist, none of which are compatible with our new, wide-bore 1.5 T PET/MRI system dedicated to radiotherapy planning. In this work, we investigated the use of 1.5 T MR-linac (MRL) receive arrays for PET/MRI, as these were designed to have a low photon attenuation for accurate dose delivery and can be connected to the new 1.5 T PET/MRI scanner. Three arrays were assessed: an 8-channel clinically-used MRL array, a 32-channel prototype MRL array, and a conventional MRI receive array. We experimentally determined, simulated, and compared the impact of these arrays on the PET sensitivity and image reconstructions. Furthermore, MRI performance was compared. Overall coil-induced PET sensitivity losses were reduced from 8.5% (conventional) to 1.7% (clinical MRL) and 0.7% (prototype MRL). Phantom measurements showed local signal errors of up to 32.7% (conventional) versus 3.6% (clinical MRL) and 3.5% (prototype MRL). Simulations with data of eight cancer patients showed average signal losses were reduced from 14.3% (conventional) to 1.2% (clinical MRL) and 1.0% (prototype MRL). MRI data showed that the signal-to-noise ratio of the MRL arrays was slightly lower at depth (110 versus 135). The parallel imaging performance of the conventional and prototype MRL arrays was similar, while the clinical MRL array's performance was lower. In conclusion, MRL arrays reducein-vivoPET signal losses >10×, which decreases, or eliminates, the need for coil AC on a new 1.5 T PET/MRI system. The prototype MRL array allows flexible coil positioning without compromising PET or MRI performance. One limitation of MRL arrays is their limited radiolucent PET window (field of view) in the craniocaudal direction.
Collapse
Affiliation(s)
- Stefan E Zijlema
- Department of Radiotherapy, University Medical Center Utrecht, Utrecht, The Netherlands.,Computational Imaging Group for MR Diagnostics & Therapy, Center for Image Sciences, University Medical Center Utrecht, The Netherlands
| | - Woutjan Branderhorst
- Department of Radiology and Nuclear Medicine, University Medical Center Utrecht, The Netherlands
| | - Remco Bastiaannet
- Department of Radiology and Nuclear Medicine, University Medical Center Utrecht, The Netherlands.,Department of Radiology, The Johns Hopkins University, School of Medicine, Baltimore, Maryland, United States of America
| | - Rob H N Tijssen
- Department of Radiotherapy, University Medical Center Utrecht, Utrecht, The Netherlands.,Department of Radiation Oncology, Catharina Hospital, Eindhoven, The Netherlands
| | - Jan J W Lagendijk
- Department of Radiotherapy, University Medical Center Utrecht, Utrecht, The Netherlands
| | - Cornelis A T van den Berg
- Department of Radiotherapy, University Medical Center Utrecht, Utrecht, The Netherlands.,Computational Imaging Group for MR Diagnostics & Therapy, Center for Image Sciences, University Medical Center Utrecht, The Netherlands
| |
Collapse
|
36
|
Plachouris D, Tzolas I, Gatos I, Papadimitroulas P, Spyridonidis T, Apostolopoulos D, Papathanasiou N, Visvikis D, Plachouri KM, Hazle JD, Kagadis GC. A deep-learning-based prediction model for the biodistribution of 90 Y microspheres in liver radioembolization. Med Phys 2021; 48:7427-7438. [PMID: 34628667 DOI: 10.1002/mp.15270] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/08/2021] [Revised: 09/24/2021] [Accepted: 09/27/2021] [Indexed: 12/15/2022] Open
Abstract
BACKGROUND Radioembolization with 90 Y microspheres is a treatment approach for liver cancer. Currently, employed dosimetric calculations exhibit low accuracy, lacking consideration of individual patient, and tissue characteristics. PURPOSE The purpose of the present study was to employ deep learning (DL) algorithms to differentiate patterns of pretreatment distribution of 99m Tc-macroaggregated albumin on SPECT/CT and post-treatment distribution of 90 Y microspheres on PET/CT and to accurately predict how the 90 Y-microspheres will be distributed in the liver tissue by radioembolization therapy. METHODS Data for 19 patients with liver cancer (10 with hepatocellular carcinoma, 5 with intrahepatic cholangiocarcinoma, 4 with liver metastases) who underwent radioembolization with 90 Y microspheres were used for the DL training. We developed a 3D voxel-based variation of the Pix2Pix model, which is a special type of conditional GANs designed to perform image-to-image translation. SPECT and CT scans along with the clinical target volume for each patient were used as inputs, as were their corresponding post-treatment PET scans. The real and predicted absorbed PET doses for the tumor and the whole liver area were compared. Our model was evaluated using the leave-one-out method, and the dose calculations were measured using a tissue-specific dose voxel kernel. RESULTS The comparison of the real and predicted PET/CT scans showed an average absorbed dose difference of 5.42% ± 19.31% and 0.44% ± 1.64% for the tumor and the liver area, respectively. The average absorbed dose differences were 7.98 ± 31.39 Gy and 0.03 ± 0.25 Gy for the tumor and the non-tumor liver parenchyma, respectively. Our model had a general tendency to underpredict the dosimetric results; the largest differences were noticed in one case, where the model underestimated the dose to the tumor area by 56.75% or 72.82 Gy. CONCLUSIONS The proposed deep-learning-based pretreatment planning method for liver radioembolization accurately predicted 90 Y microsphere biodistribution. Its combination with a rapid and accurate 3D dosimetry method will render it clinically suitable and could improve patient-specific pretreatment planning.
Collapse
Affiliation(s)
- Dimitris Plachouris
- Department of Medical Physics, School of Medicine, University of Patras, Rion, Greece
| | - Ioannis Tzolas
- School of Electrical and Computer Engineering, University of Patras, Rion, Greece
| | - Ilias Gatos
- Department of Medical Physics, School of Medicine, University of Patras, Rion, Greece
| | - Panagiotis Papadimitroulas
- Department of Medical Physics, School of Medicine, University of Patras, Rion, Greece.,R&D Department, Bioemission Technology Solutions, Athens, Greece
| | - Trifon Spyridonidis
- Department of Nuclear Medicine, School of Medicine, University of Patras, Rion, Greece
| | | | | | | | | | - John D Hazle
- Department of Imaging Physics, The University of Texas MD Anderson Cancer Center, Houston, Texas, USA
| | - George C Kagadis
- Department of Medical Physics, School of Medicine, University of Patras, Rion, Greece.,Department of Imaging Physics, The University of Texas MD Anderson Cancer Center, Houston, Texas, USA
| |
Collapse
|
37
|
Assessment of radiation sensitivity of unresectable intrahepatic cholangiocarcinoma in a series of patients submitted to radioembolization with yttrium-90 resin microspheres. Sci Rep 2021; 11:19745. [PMID: 34611210 PMCID: PMC8492793 DOI: 10.1038/s41598-021-99219-7] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/20/2021] [Accepted: 08/25/2021] [Indexed: 01/23/2023] Open
Abstract
Radioembolization is a valuable therapeutic option in patients with unresectable intrahepatic cholangiocarcinoma. The essential implementation of the absorbed dose calculation methods should take into account also the specific tumor radiosensitivity, expressed by the α parameter. Purpose of this study was to retrospectively calculate it in a series of patients with unresectable intrahepatic cholangiocarcinoma submitted to radioembolization. Twenty-one therapeutic procedures in 15 patients were analysed. Tumor absorbed doses were calculated processing the post-therapeutic 90Y-PET/CT images and the pre-treatment contrast-enhanced CT scans. Tumor absorbed dose and pre- and post-treatment tumor volumes were used to calculate α and α3D parameters (dividing targeted liver in n voxels of the same volume with specific voxel absorbed dose). A tumor volume reduction was observed after treatment. The median of tumor average absorbed dose was 93 Gy (95% CI 81–119) and its correlation with the residual tumor mass was statistically significant. The median of α and α3D parameters was 0.005 Gy−1 (95% CI 0.004–0.008) and 0.007 Gy−1 (95% CI 0.005–0.015), respectively. Multivariate analysis showed tumor volume and tumor absorbed dose as significant predictors of the time to tumor progression. The knowledge of radiobiological parameters gives the possibility to decide the administered activity in order to improve the outcome of the treatment.
Collapse
|
38
|
Georgiou MF, Kuker RA, Studenski MT, Ahlman PP, Witte M, Portelance L. Lung shunt fraction calculation using 99mTc-MAA SPECT/CT imaging for 90Y microsphere selective internal radiation therapy of liver tumors. EJNMMI Res 2021; 11:96. [PMID: 34585259 PMCID: PMC8479035 DOI: 10.1186/s13550-021-00837-z] [Citation(s) in RCA: 11] [Impact Index Per Article: 2.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/13/2021] [Accepted: 09/11/2021] [Indexed: 01/16/2023] Open
Abstract
BACKGROUND 99mTc-macroaggregated albumin (99mTc-MAA) scintigraphy is utilized in treatment planning for Yttrium-90 (90Y) Selective Internal Radiation Therapy (SIRT) of liver tumors to evaluate hepatopulmonary shunting by calculating the lung shunt fraction (LSF). The purpose of this study was to evaluate if LSF calculation using SPECT/CT instead of planar gamma camera imaging is more accurate and if this can potentially lead to more effective treatment planning of hepatic lesions while avoiding excessive pulmonary irradiation. RESULTS LSF calculation was obtained using two different methodologies in 85 cases from consecutive patients intended to receive 90Y SIRT. The first method was based on planar gamma camera imaging in the anterior and posterior views with geometric mean calculation of the LSF from regions of interest of the liver and lungs. The second method was based on segmentation of the liver and lungs from SPECT/CT images of the thorax and abdomen. The differences in planar imaging versus SPECT/CT derived LSF values along with the estimated absorbed lung mean dose (LMD) were evaluated. The LSF values were higher in planar imaging versus SPECT/CT in 81/85 cases, with a mean value of 8.5% vs. 4.6% respectively; the difference was statistically significant using a paired t-test (alpha = 0.05). In those patients who received SIRT, the estimated absorbed LMD calculated with planar imaging was significantly higher than with SPECT/CT (t-test, P < 0.005). Repeated phantom experiments using an anthropomorphic torso phantom with variable 99mTc activity concentrations for the liver and lungs were performed with the standard patient protocol, demonstrated improved accuracy of the LSF calculation based on SPECT/CT than planar imaging (mean overestimated value of 6% vs. 26%). CONCLUSIONS This study demonstrates that LSF calculation using planar imaging can be significantly overestimated while calculation using SPECT/CT imaging and appropriate segmentation tools can be more accurate. Minimizing the errors in obtaining the LSF can lead to more effective 90Y SIRT treatment planning for hepatic tumors while ensuring the lung dose will not exceed the standard acceptable safety thresholds.
Collapse
Affiliation(s)
- Mike F Georgiou
- Department of Radiology, Miller School of Medicine, University of Miami, 1611 NW 12th Avenue, JMH C-248, Miami, FL, 33136, USA.
| | - Russ A Kuker
- Department of Radiology, Miller School of Medicine, University of Miami, 1611 NW 12th Avenue, JMH C-248, Miami, FL, 33136, USA
| | - Matthew T Studenski
- Department of Radiation Oncology, Miller School of Medicine, University of Miami, Miami, FL, USA
| | - Preeti P Ahlman
- Department of Radiology, Miller School of Medicine, University of Miami, 1611 NW 12th Avenue, JMH C-248, Miami, FL, 33136, USA
| | - Megan Witte
- Department of Biomedical Engineering, University of Miami, Miami, FL, USA
| | - Lorraine Portelance
- Department of Radiation Oncology, Miller School of Medicine, University of Miami, Miami, FL, USA
| |
Collapse
|
39
|
Accurate non-tumoral 99mTc-MAA absorbed dose prediction to plan optimized activities in liver radioembolization using resin microspheres. Phys Med 2021; 89:250-257. [PMID: 34438353 DOI: 10.1016/j.ejmp.2021.07.032] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 02/15/2021] [Revised: 07/23/2021] [Accepted: 07/28/2021] [Indexed: 12/19/2022] Open
Abstract
AIM The manufacturers' recommended methods to calculate delivered activities in liver radioembolization are simplistic and only slightly personalized. Activity planning could also be based on a 99mTc-macroaggregated albumin SPECT/CT (MAA) using the partition model but its accuracy is controversial. This study evaluates the dose parameters in the normal liver and in the tumor compartments using MAA SPECT/CT (pre-therapeutic imaging) and 90Y TOF-PET/CT (post-therapy imaging). Finally, we propose a prescription of the activity as a function of the normal liver MAA distribution. METHOD 66 procedures of RE (with resin microspheres) corresponding to 171 lesions were analyzed. Tumor to normal targeted liver uptake (T/NTL), tumor absorbed dose (TD) and whole normal liver absorbed (WNLD) were assessed with MAA and 90Y imaging. Secondly, activities were recalculated using the MAA distribution in the normal liver compartment to reach the maximal tolerable liver dose. These Activities were compared to activities defined with the BSA method. RESULTS Compared to 90Y imaging, our study demonstrated an accurate estimation of the WNLD using MAA imaging (Pearson's R = 0.97, p < 0.001). On the contrary, significant variations were found for TD (R = 0.65, p < 0.001). The MAA T/NTL ratio has a 85% positive predictive value in identifying patients who will get a 90Y T/NTL ratio above 1.5. Moreover, activities calculated using the MAA distribution in the normal liver compartment were significantly higher to activities defined with the BSA method. CONCLUSION Whole normal liver absorbed doses are accurately predicted with MAA imaging and could be used to optimize the activity planning.
Collapse
|
40
|
Yıldırım AK, Kökkülünk HT. Comparison of Y-90 and Ho-166 Dosimetry Using Liver Phantom: A Monte Carlo Study. Anticancer Agents Med Chem 2021; 22:1348-1353. [PMID: 34431467 DOI: 10.2174/1871520621666210824111534] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/12/2021] [Revised: 07/06/2021] [Accepted: 07/15/2021] [Indexed: 11/22/2022]
Abstract
BACKGROUND It is estimated that more than 1 million people are diagnosed with liver malignancy each year and one of the treatments is radioembolization with Y-90 and Ho-166. <P> Objective: The aim of this study is to calculate the absorbed doses caused by Y-90 and Ho-166 in tumor and liver parenchyma using a phantom via Monte Carlo method. <P> Methods: A liver model phantom including a tumor imitation of sphere (r =1.5cm) was defined in GATE. The total activity of 40 mCi Y-90 and Ho-166 was prescribed into tumor imitation as source and 2x2x2 mm3 voxel-sized DoseActors were identified at 30 locations. The simulation, performed to calculate the absorbed doses left by particles during 1 second for Y-90 and Ho-166, was run for a total of 10 days and 11 days, respectively. Total doses were calculated by taking the doses occurring in 1 second as a reference. <P> Results: The maximum absorbed doses were found to be 2.334E+03±1.576E+01 Gy for Y-90 and 7.006E+02±6.013E-01 Gy for Ho-166 at the center of tumor imitation. The minimum absorbed doses were found to be 2.133E-03±1.883E-01 Gy for Y-90 and 1.152E-02±1.036E-03 Gy for Ho-166 at the farthest location from source. The mean absorbed doses in tumor imitation were found to be 1.50E+03±1.36E+00 Gy and 4.58E+02±4.75E-01 Gy for Y-90 and Ho-166, respectively. And, the mean absorbed doses in normal parenchymal tissue were found to be2.07E+01±9.58E-02 Gy and 3.79E+00±2.63E-02 Gy for Y-90 and Ho-166, respectively. <P> Conclusion: Based on the results, Ho-166 is a good alternative to Y-90 according to dosimetric evaluation.
Collapse
|
41
|
Conventional Hepatic Volumetry May Lead to Inaccurate Segmental Yttrium-90 Radiation Dosimetry. Cardiovasc Intervent Radiol 2021; 44:1973-1985. [PMID: 34414494 DOI: 10.1007/s00270-021-02898-y] [Citation(s) in RCA: 6] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 09/26/2020] [Accepted: 06/10/2021] [Indexed: 12/17/2022]
Abstract
OBJECTIVE To compare radioembolization treatment zone volumes from mapping cone beam CT (CBCT) versus planning CT/MRI and to model their impact on dosimetry. METHODS Y90 cases were retrospectively identified in which intra-procedural CBCT angiograms were performed. Segmental and lobar treatment zone volumes were calculated with semi-automated contouring using Couinaud venous anatomy (planning CT/MRI) or tumor angiosome enhancement (CBCT). Differences were compared with a Wilcoxon signed-rank test. Treatment zone-specific differences in segmental volumes by volumetric method were also calculated and used to model differences in delivered dose using medical internal radiation dosimetry (MIRD) at 200 and 120 Gy targets. Anatomic, pathologic, and technical factors likely affecting segmental volumes by volumetric method were evaluated. RESULTS Forty segmental and 48 lobar CBCT angiograms and corresponding planning CT/MRI scans were included. Median Couinaud- and CBCT-derived segmental volumes were 281 and 243 mL, respectively (p = 0.005). Differences between Couinaud and CBCT lobar volumes (right, left) were not significant (p = 0.24, p = 0.07). Couinaud overestimated segmental volumes in 28 cases by a median of 98 mL (83%) and underestimated in 12 cases by median 69 mL (20%). At a 200 Gy dose target, Couinaud estimates produced median delivered doses of 367 and 160 Gy in these 28 and 12 cases. At a 120 Gy target, Couinaud produced doses of 220 and 96 Gy. Proximal vs. distal microcatheter positioning, variant arterial anatomy, and tumor location on or near segmental watersheds were leading factors linked to volumetric differences. CONCLUSION Use of CBCT-based volumetry may allow more accurate, personalized dosimetry for segmental Y90 radioembolization.
Collapse
|
42
|
d'Abadie P, Walrand S, Hesse M, Annet L, Borbath I, Van den Eynde M, Lhommel R, Jamar F. Prediction of tumor response and patient outcome after radioembolization of hepatocellular carcinoma using 90Y-PET-computed tomography dosimetry. Nucl Med Commun 2021; 42:747-754. [PMID: 33741864 DOI: 10.1097/mnm.0000000000001395] [Citation(s) in RCA: 6] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/19/2022]
Abstract
AIM 90Y-radioembolization using glass or resin microspheres is increasingly used for the treatment of hepatocellular carcinoma (HCC). The aim of this retrospective study is to determine the prognostic relevance of dosimetric parameters defined with 90Y-PET-CT obtained immediately after radioembolization. METHODS Forty-five HCC patients, mostly with multiple lesions, were treated by radioembolization between 2011 and 2017. After treatment, all underwent a 90Y PET-CT with time of flight reconstruction (90Y-TOF-PET-CT). Tumor absorbed dose and cumulative tumor dose-volume histogram were calculated using a dose point Kernel convolution algorithm. The radiological tumor response was assessed using modified (m)-RECIST criteria. Progression-free-survival (PFS) and overall survival (OS) were analyzed using the Kaplan-Meier method and Cox regression analysis. RESULTS Twenty-six patients were treated with glass microspheres (73 lesions) and nineteen with resin microspheres (60 lesions). Thresholds of 118 and 61 Gy for glass and resin microspheres respectively correlate well with radiological response with a positive predictive value (PPV) of 98 and 80% and discriminate patient outcome with regard to PFS (P = 0.03 and 0.005) and OS (P = 0.003 and 0.007). Using dose volume histogram, a minimal absorbed dose of 40 Gy in 66% of the tumor volume (defined as D66) was highly predictive of radiological response (PPV = 94%), PFS (P < 0.001) and OS (P = 0. 008), for either device. CONCLUSION Dosimetric parameters obtained using 90Y-PET-CT are predictive of tumor response, PFS and OS. In clinical practice, a systematic dosimetric evaluation using 90Y PET should be implemented to help predicting patient outcomes.
Collapse
Affiliation(s)
| | | | | | | | - Ivan Borbath
- Gastroenterology and Oncology, Cliniques Universitaires Saint Luc, Université Catholique de Louvain, Brussels, Belgium
| | - Marc Van den Eynde
- Gastroenterology and Oncology, Cliniques Universitaires Saint Luc, Université Catholique de Louvain, Brussels, Belgium
| | | | | |
Collapse
|
43
|
d’Abadie P, Hesse M, Louppe A, Lhommel R, Walrand S, Jamar F. Microspheres Used in Liver Radioembolization: From Conception to Clinical Effects. Molecules 2021; 26:3966. [PMID: 34209590 PMCID: PMC8271370 DOI: 10.3390/molecules26133966] [Citation(s) in RCA: 26] [Impact Index Per Article: 6.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/28/2021] [Revised: 06/22/2021] [Accepted: 06/23/2021] [Indexed: 01/31/2023] Open
Abstract
Inert microspheres, labeled with several radionuclides, have been developed during the last two decades for the intra-arterial treatment of liver tumors, generally called Selective Intrahepatic radiotherapy (SIRT). The aim is to embolize microspheres into the hepatic capillaries, accessible through the hepatic artery, to deliver high levels of local radiation to primary (such as hepatocarcinoma, HCC) or secondary (metastases from several primary cancers, e.g., colorectal, melanoma, neuro-endocrine tumors) liver tumors. Several types of microspheres were designed as medical devices, using different vehicles (glass, resin, poly-lactic acid) and labeled with different radionuclides, 90Y and 166Ho. The relationship between the microspheres' properties and the internal dosimetry parameters have been well studied over the last decade. This includes data derived from the clinics, but also computational data with various millimetric dosimetry and radiobiology models. The main purpose of this paper is to define the characteristics of these radiolabeled microspheres and explain their association with the microsphere distribution in the tissues and with the clinical efficacy and toxicity. This review focuses on avenues to follow in the future to optimize such particle therapy and benefit to patients.
Collapse
Affiliation(s)
- Philippe d’Abadie
- Department of Nuclear Medicine, Cliniques Universitaires Saint Luc, Université Catholique de Louvain, 1200 Brussels, Belgium; (M.H.); (A.L.); (R.L.); (S.W.); (F.J.)
| | | | | | | | | | | |
Collapse
|
44
|
Van BJ, Dewaraja YK, Sangogo ML, Mikell JK. Y-90 SIRT: evaluation of TCP variation across dosimetric models. EJNMMI Phys 2021; 8:45. [PMID: 34114115 PMCID: PMC8192668 DOI: 10.1186/s40658-021-00391-6] [Citation(s) in RCA: 6] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/14/2021] [Accepted: 05/28/2021] [Indexed: 11/24/2022] Open
Abstract
Introduction Much progress has been made in implementing selective internal radiation therapy (SIRT) as a viable treatment option for hepatic malignancies. However, there is still much need for improved options for calculating the amount of activity to be administered. To make advances towards this goal, this study examines the relationship between predicted biological outcomes of liver tumors via tumor control probabilities (TCP) and parenchyma via normal tissue complication probabilities (NTCP) given variations in absorbed dose prescription methodologies. Methods Thirty-nine glass microsphere treatments in 35 patients with hepatocellular carcinoma or metastatic liver disease were analyzed using 99mTc-MAA SPECT/CT and 90Y PET/CT scans. Predicted biological outcomes corresponding to the single compartment (standard) model and multi-compartment (partition) dosimetry model were compared using our previously derived TCP dose-response curves over a range of 80–150 Gy prescribed absorbed dose to the perfused volume, recommended in the package insert for glass microspheres. Retrospective planning dosimetry was performed on the MAA SPECT/CT; changes from the planned infused activity due to selection of absorbed dose level and dosimetry model (standard or partition) were used to scale absorbed doses reported from 90Y PET/CT including liver parenchyma and lesions (N = 120) > 2 ml. A parameterized charting system was developed across all potential prescription options to enable a clear relationship between standard prescription vs. the partition model-based prescription. Using a previously proposed NTCP model, the change in prescribed dose from a standard model prescription of 120 Gy to the perfused volume to a 15% NTCP prescription to the normal liver was explored. Results Average TCP predictions for the partition model compared with the standard model varied from a 13% decrease to a 32% increase when the prescribed dose was varied across the range of 80–150 Gy. In the parametrized chart comparing absorbed dose prescription ranges across the standard model and partition models, a line of equivalent absorbed dose to a tumor was identified. TCP predictions on a per lesion basis varied between a 26% decrease and a 81% increase for the most commonly chosen prescription options when comparing the partition model with the standard model. NTCP model was only applicable to a subset of patients because of the small volume fraction of the liver that was targeted in most cases. Conclusion Our retrospective analysis of patient imaging data shows that the choice of prescribed dose and which model to prescribe potentially contribute to a wide variation in average tumor efficacy. Biological response data should be included as one factor when looking to improve patient care in the clinic. The use of parameterized charting, such as presented here, will help direct physicians when transitioning to newer prescription methods. Supplementary Information The online version contains supplementary material available at 10.1186/s40658-021-00391-6.
Collapse
Affiliation(s)
- Benjamin J Van
- Department of Radiology, University of Michigan, Ann Arbor, MI, 48109, USA.
| | - Yuni K Dewaraja
- Department of Radiology, University of Michigan, Ann Arbor, MI, 48109, USA
| | - Mamadou L Sangogo
- Department of Radiology, University of Michigan, Ann Arbor, MI, 48109, USA
| | - Justin K Mikell
- Department of Radiation Oncology, University of Michigan, Ann Arbor, 48109, MI, USA
| |
Collapse
|
45
|
Lu Z, Chen G, Lin KH, Wu TH, Mok GSP. Evaluation of different CT maps for attenuation correction and segmentation in static 99m Tc-MAA SPECT/CT for 90 Y radioembolization treatment planning: A simulation study. Med Phys 2021; 48:3842-3851. [PMID: 34013551 DOI: 10.1002/mp.14991] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/23/2020] [Revised: 05/04/2021] [Accepted: 05/08/2021] [Indexed: 11/08/2022] Open
Abstract
PURPOSE Conventional 99m Tc-macroaggregated albumin (99m Tc-MAA) planar scintigraphy overestimates lung shunt fraction (LSF) compared to SPECT/CT. However, the respiratory motion artifact due to the temporal mismatch between static SPECT and helical CT (HCT) may compromise the SPECT quantitation accuracy by incorrect attenuation correction (AC) and volume-of-interest (VOI) segmentation. This study aims to evaluate AC and VOI segmentation effects systematically and to propose a CT map for LSF and tumor-to-normal liver ratio (TNR) estimation in static 99m Tc-MAA SPECT/CT. METHODS The 4D XCAT phantom was used to simulate a phantom population of 120 phantoms, modeling 10 different anatomical variations, nine TNRs (2-13.2), nine tumor sizes (2-6.7 cm diameter), eight tumor locations, three axial motion amplitudes of 1, 1.5, and 2 (cm), and four LSFs of 5%, 10%, 15%, and 20%. An analytical projector for low-energy high-resolution parallel-hole collimator was used to simulate 60 noisy projections over 360°, modeling attenuation and geometric collimator-detector response (GCDR). AC and VOI mismatch effects were investigated independently and together, using cine average CT (CACT), HCT at end-inspiration (HCT-IN), mid-respiration (HCT-MID), and end-expiration (HCT-EX) respectively as attenuation and segmentation maps. SPECT images without motion, AC, and VOI errors were also generated as reference. LSF and TNR errors were measured as compared to the ground truth. RESULTS HCT-MID has slightly better performance for AC effect compared with other CT maps in LSF and TNR estimation, while HCT-EX and HCT-MID perform better for VOI effect. For a respiratory motion amplitude of 1.5 cm and a LSF of 5%, the LSF errors are 19.56 ± 4.58%, -6.79 ± 1.74%, 77.29 ± 14.74%, and 111.25 ± 18.29% corresponding to HCT-MID, HCT-EX, HCT-IN, and CACT in static SPECT. The TNR errors are -12.38 ± 6.42%, -20.55 ± 11.25%, -20.89 ± 9.98%, and -22.89 ± 14.38% respectively. HCT-MID has the best performance for LSF estimation for LSF > 10% and TNR estimation, followed by HCT-EX, HCT-IN, and CACT. CONCLUSIONS The HCT-MID is recommended for AC and segmentation to alleviate respiratory artifacts and improve quantitation accuracy in 90 Y radioembolization treatment planning. HCT-EX would also be a recommended choice if HCT-MID is not available.
Collapse
Affiliation(s)
- Zhonglin Lu
- Biomedical Imaging Laboratory (BIG), Department of Electrical and Computer Engineering, Faculty of Science and Technology, University of Macau, Avenida da Universidade, Taipa, Macau SAR, China
| | - Gefei Chen
- Biomedical Imaging Laboratory (BIG), Department of Electrical and Computer Engineering, Faculty of Science and Technology, University of Macau, Avenida da Universidade, Taipa, Macau SAR, China
| | - Kuan-Heng Lin
- Department of Biomedical Imaging and Radiological Sciences, National Yang Ming Chiao Tung University, Taipei, Taiwan.,Industrial PhD Program of Biomedical Science and Engineering, National Yang Ming Chiao Tung University, Taipei, Taiwan
| | - Tung-Hsin Wu
- Department of Biomedical Imaging and Radiological Sciences, National Yang Ming Chiao Tung University, Taipei, Taiwan
| | - Greta S P Mok
- Biomedical Imaging Laboratory (BIG), Department of Electrical and Computer Engineering, Faculty of Science and Technology, University of Macau, Avenida da Universidade, Taipa, Macau SAR, China.,Center for Cognitive and Brain Sciences, Institute of Collaborative Innovation, University of Macau, Avenida da Universidade, Taipa, Macau SAR, China
| |
Collapse
|
46
|
Sarrut D, Bała M, Bardiès M, Bert J, Chauvin M, Chatzipapas K, Dupont M, Etxebeste A, M Fanchon L, Jan S, Kayal G, S Kirov A, Kowalski P, Krzemien W, Labour J, Lenz M, Loudos G, Mehadji B, Ménard L, Morel C, Papadimitroulas P, Rafecas M, Salvadori J, Seiter D, Stockhoff M, Testa E, Trigila C, Pietrzyk U, Vandenberghe S, Verdier MA, Visvikis D, Ziemons K, Zvolský M, Roncali E. Advanced Monte Carlo simulations of emission tomography imaging systems with GATE. Phys Med Biol 2021; 66:10.1088/1361-6560/abf276. [PMID: 33770774 PMCID: PMC10549966 DOI: 10.1088/1361-6560/abf276] [Citation(s) in RCA: 62] [Impact Index Per Article: 15.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/09/2020] [Accepted: 03/26/2021] [Indexed: 12/13/2022]
Abstract
Built on top of the Geant4 toolkit, GATE is collaboratively developed for more than 15 years to design Monte Carlo simulations of nuclear-based imaging systems. It is, in particular, used by researchers and industrials to design, optimize, understand and create innovative emission tomography systems. In this paper, we reviewed the recent developments that have been proposed to simulate modern detectors and provide a comprehensive report on imaging systems that have been simulated and evaluated in GATE. Additionally, some methodological developments that are not specific for imaging but that can improve detector modeling and provide computation time gains, such as Variance Reduction Techniques and Artificial Intelligence integration, are described and discussed.
Collapse
Affiliation(s)
- David Sarrut
- Université de Lyon, CREATIS, CNRS UMR5220, Inserm U1294, INSA-Lyon, Université Lyon 1, Lyon, France
| | | | - Manuel Bardiès
- Cancer Research Institute of Montpellier, U1194 INSERM/ICM/Montpellier University, 208 Av des Apothicaires, F-34298 Montpellier cedex 5, France
| | - Julien Bert
- LaTIM, INSERM UMR 1101, IBRBS, Faculty of Medicine, Univ Brest, 22 avenue Camille Desmoulins, F-29238, Brest, France
| | - Maxime Chauvin
- CRCT, UMR 1037, INSERM, Université Toulouse III Paul Sabatier, Toulouse, France
| | | | | | - Ane Etxebeste
- Université de Lyon, CREATIS, CNRS UMR5220, Inserm U1294, INSA-Lyon, Université Lyon 1, Lyon, France
| | - Louise M Fanchon
- Department of Medical Physics, Memorial Sloan Kettering Cancer Center, New York, NY, 10065, United States of America
| | - Sébastien Jan
- Université Paris-Saclay, CEA, CNRS, Inserm, BioMaps, Service Hospitalier Frédéric Joliot, F-91401, Orsay, France
| | - Gunjan Kayal
- CRCT, UMR 1037, INSERM, Université Toulouse III Paul Sabatier, Toulouse, France
- SCK CEN, Belgian Nuclear Research Centre, Boeretang 200, Mol 2400, Belgium
| | - Assen S Kirov
- Department of Medical Physics, Memorial Sloan Kettering Cancer Center, New York, NY, 10065, United States of America
| | - Paweł Kowalski
- High Energy Physics Division, National Centre for Nuclear Research, Otwock-Świerk, Poland
| | - Wojciech Krzemien
- High Energy Physics Division, National Centre for Nuclear Research, Otwock-Świerk, Poland
| | - Joey Labour
- Université de Lyon, CREATIS, CNRS UMR5220, Inserm U1294, INSA-Lyon, Université Lyon 1, Lyon, France
| | - Mirjam Lenz
- FH Aachen University of Applied Sciences, Forschungszentrum Jülich, Jülich, Germany
- Faculty of Mathematics and Natural Sciences, University of Wuppertal, Wuppertal, Germany
| | - George Loudos
- Bioemission Technology Solutions (BIOEMTECH), Alexandras Av. 116, Athens, Greece
| | | | - Laurent Ménard
- Université Paris-Saclay, CNRS/IN2P3, IJCLab, F-91405 Orsay, France
- Université de Paris, IJCLab, F-91405 Orsay France
| | | | | | - Magdalena Rafecas
- Institute of Medical Engineering, University of Lübeck, Lübeck, Germany
| | - Julien Salvadori
- Department of Nuclear Medicine and Nancyclotep molecular imaging platform, CHRU-Nancy, Université de Lorraine, F-54000, Nancy, France
| | - Daniel Seiter
- Department of Medical Physics, University of Wisconsin-Madison School of Medicine and Public Health, Madison, WI, 53705, United States of America
| | - Mariele Stockhoff
- Medical Image and Signal Processing (MEDISIP), Ghent University, Ghent, Belgium
| | - Etienne Testa
- Univ. Lyon, Univ. Claude Bernard Lyon 1, CNRS/IN2P3, IP2I Lyon, F-69622, Villeurbanne, France
| | - Carlotta Trigila
- Department of Biomedical Engineering, University of California, Davis, CA 95616 United States of America
| | - Uwe Pietrzyk
- Faculty of Mathematics and Natural Sciences, University of Wuppertal, Wuppertal, Germany
| | | | - Marc-Antoine Verdier
- Université Paris-Saclay, CNRS/IN2P3, IJCLab, F-91405 Orsay, France
- Université de Paris, IJCLab, F-91405 Orsay France
| | - Dimitris Visvikis
- LaTIM, INSERM UMR 1101, IBRBS, Faculty of Medicine, Univ Brest, 22 avenue Camille Desmoulins, F-29238, Brest, France
| | - Karl Ziemons
- FH Aachen University of Applied Sciences, Forschungszentrum Jülich, Jülich, Germany
| | - Milan Zvolský
- Institute of Medical Engineering, University of Lübeck, Lübeck, Germany
| | - Emilie Roncali
- Department of Biomedical Engineering, University of California, Davis, CA 95616 United States of America
| |
Collapse
|
47
|
Henry EC, Strugari M, Mawko G, Brewer KD, Abraham R, Kappadath SC, Syme A. Post-administration dosimetry in yttrium-90 radioembolization through micro-CT imaging of radiopaque microspheres in a porcine renal model. Phys Med Biol 2021; 66. [PMID: 33784639 DOI: 10.1088/1361-6560/abf38a] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/25/2021] [Accepted: 03/30/2021] [Indexed: 12/27/2022]
Abstract
The purpose of this study is to perform post-administration dosimetry in yttrium-90 radioembolization through micro-CT imaging of radiopaque microsphere distributions in a porcine renal model and explore the impact of spatial resolution of an imaging system on the extraction of specific dose metrics. Following the administration of radiopaque microspheres to the kidney of a hybrid farm pig, the kidney was explanted and imaged with micro-CT. To produce an activity distribution, 400 MBq of yttrium-90 activity was distributed throughout segmented voxels of the embolized vasculature based on an established linear relationship between microsphere concentration and CT voxel value. This distribution was down-sampled to coarser isotropic grids ranging in voxel size from 2.5 to 15 mm to emulate nominal resolutions comparable to those found in yttrium-90 PET and Bremsstrahlung SPECT imaging. Dose distributions were calculated through the convolution of activity distributions with dose-voxel kernels generated using the GATE Monte Carlo toolkit. Contours were computed to represent normal tissue and target volumes. Dose-volume histograms, dose metrics, and dose profiles were compared to a ground truth dose distribution computed with GATE. The mean dose to the target for all studied voxel sizes was found to be within 5.7% of the ground truth mean dose.D70was shown to be strongly correlated with image voxel size of the dose distribution (r2 = 0.90).D70is cited in the literature as an important dose metric and its dependence on voxel size suggests higher resolution dose distributions may provide new perspectives on dose-response relationships in yttrium-90 radioembolization. This study demonstrates that dose distributions with large voxels incorrectly homogenize the dose by attributing escalated doses to normal tissues and reduced doses in high-dose target regions. High-resolution micro-CT imaging of radiopaque microsphere distributions can provide increased confidence in characterizing the absorbed dose heterogeneity in yttrium-90 radioembolization.
Collapse
Affiliation(s)
- E Courtney Henry
- Department of Physics and Atmospheric Science, Dalhousie University, Halifax, Canada
| | - Matthew Strugari
- Department of Physics and Atmospheric Science, Dalhousie University, Halifax, Canada.,Biomedical Translational Imaging Centre, Halifax, Canada
| | - George Mawko
- Department of Physics and Atmospheric Science, Dalhousie University, Halifax, Canada.,Department of Diagnostic Radiology, Dalhousie University, Halifax, Canada.,Department of Medical Physics, Nova Scotia Health Authority, Halifax, Canada.,Department of Radiation Oncology, Dalhousie University, Halifax, Canada
| | - Kimberly D Brewer
- Department of Physics and Atmospheric Science, Dalhousie University, Halifax, Canada.,Biomedical Translational Imaging Centre, Halifax, Canada.,Department of Diagnostic Radiology, Dalhousie University, Halifax, Canada.,Department of Biomedical Engineering, Dalhousie University, Halifax, Canada
| | - Robert Abraham
- Department of Diagnostic Radiology, Dalhousie University, Halifax, Canada.,ABK Biomedical Inc., Halifax, Canada
| | - S Cheenu Kappadath
- Department of Imaging Physics, University of Texas MD Anderson Cancer Centre, Houston, United States of America
| | - Alasdair Syme
- Department of Physics and Atmospheric Science, Dalhousie University, Halifax, Canada.,Department of Medical Physics, Nova Scotia Health Authority, Halifax, Canada.,Department of Radiation Oncology, Dalhousie University, Halifax, Canada
| |
Collapse
|
48
|
Roosen J, Klaassen NJM, Westlund Gotby LEL, Overduin CG, Verheij M, Konijnenberg MW, Nijsen JFW. To 1000 Gy and back again: a systematic review on dose-response evaluation in selective internal radiation therapy for primary and secondary liver cancer. Eur J Nucl Med Mol Imaging 2021; 48:3776-3790. [PMID: 33839892 PMCID: PMC8484215 DOI: 10.1007/s00259-021-05340-0] [Citation(s) in RCA: 29] [Impact Index Per Article: 7.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/08/2020] [Accepted: 03/25/2021] [Indexed: 12/21/2022]
Abstract
Purpose To systematically review all current evidence into the dose-response relation of yttrium-90 and holmium-166 selective internal radiation therapy (SIRT) in primary and secondary liver cancer. Methods A standardized search was performed in PubMed (MEDLINE), Embase, and the Cochrane Library in order to identify all published articles on dose-response evaluation in SIRT. In order to limit the results, all articles that investigated SIRT in combination with other therapy modalities (such as chemotherapy) were excluded. Results A total of 3038 records were identified of which 487 were screened based on the full text. Ultimately, 37 studies were included for narrative analysis. Meta-analysis could not be performed due to the large heterogeneity in study and reporting designs. Out of 37 studies, 30 reported a ‘mean dose threshold’ that needs to be achieved in order to expect a response. This threshold appears to be higher for hepatocellular carcinoma (HCC, 100–250 Gy) than for colorectal cancer metastases (CRC, 40–60 Gy). Reported thresholds tend to be lower for resin microspheres than when glass microspheres are used. Conclusion Although the existing evidence demonstrates a dose-response relationship in SIRT for both primary liver tumours and liver metastases, many pieces of the puzzle are still missing, hampering the definition of standardized dose thresholds. Nonetheless, most current evidence points towards a target mean dose of 100–250 Gy for HCC and 40–60 Gy for CRC. The field would greatly benefit from a reporting standard and prospective studies designed to elucidate the dose-response relation in different tumour types. Supplementary Information The online version contains supplementary material available at 10.1007/s00259-021-05340-0.
Collapse
Affiliation(s)
- Joey Roosen
- Department of Medical Imaging, Radboud Institute for Health Sciences, Radboud University Medical Center, Nijmegen, The Netherlands
| | - Nienke J M Klaassen
- Department of Medical Imaging, Radboud Institute for Health Sciences, Radboud University Medical Center, Nijmegen, The Netherlands
| | - Lovisa E L Westlund Gotby
- Department of Medical Imaging, Radboud Institute for Health Sciences, Radboud University Medical Center, Nijmegen, The Netherlands
| | - Christiaan G Overduin
- Department of Medical Imaging, Radboud Institute for Health Sciences, Radboud University Medical Center, Nijmegen, The Netherlands
| | - Marcel Verheij
- Department of Radiation Oncology, Radboud University Medical Center, Nijmegen, The Netherlands
| | - Mark W Konijnenberg
- Department of Medical Imaging, Radboud Institute for Health Sciences, Radboud University Medical Center, Nijmegen, The Netherlands
- Department of Radiology and Nuclear Medicine, Erasmus Medical Center, Rotterdam, The Netherlands
| | - J Frank W Nijsen
- Department of Medical Imaging, Radboud Institute for Health Sciences, Radboud University Medical Center, Nijmegen, The Netherlands.
| |
Collapse
|
49
|
Nodari G, Popoff R, Riedinger JM, Lopez O, Pellegrinelli J, Dygai-Cochet I, Tabouret-Viaud C, Presles B, Chevallier O, Gehin S, Gallet M, Latournerie M, Manfredi S, Loffroy R, Vrigneaud JM, Cochet A. Impact of contouring methods on pre-treatment and post-treatment dosimetry for the prediction of tumor control and survival in HCC patients treated with selective internal radiation therapy. EJNMMI Res 2021; 11:24. [PMID: 33687596 PMCID: PMC7943673 DOI: 10.1186/s13550-021-00766-x] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/28/2020] [Accepted: 02/23/2021] [Indexed: 12/16/2022] Open
Abstract
INTRODUCTION The aim of this study was to evaluate the impact of the contouring methods on dose metrics and their predictive value on tumor control and survival, in both situations of pre-treatment and post-treatment dosimetry, for patients with advanced HCC treated with SIRT. METHODS Forty-eight patients who underwent SIRT between 2012 and 2020 were retrospectively included in this study. Target volumes were delineated using two methods: MRI-based contours manually drawn by a radiologist and then registered on SPECT/CT and PET/CT via deformable registration (Pre-CMRI and Post-CMRI), 99mTc-MAA-SPECT and 90Y-microspheres-PET 10% threshold contouring (Pre-CSPECT and Post-CPET). The mean absorbed dose (Dm) and the minimal absorbed dose delivered to 70% of the tumor volume (D70) were evaluated with both contouring methods; the tumor-to-normal liver uptake ratio (TNR) was evaluated with MRI-based contours only. Tumor response was assessed using the mRECIST criteria on the follow-up MRIs. RESULTS No significant differences were found for Dm and TNR between pre- and post-treatment. TNR evaluated with radiologic contours (Pre-CMRI and Post-CMRI) were predictive of tumor control at 6 months on pre- and post-treatment dosimetry (OR 5.9 and 7.1, respectively; p = 0.02 and 0.01). All dose metrics determined with both methods were predictive of overall survival (OS) on pre-treatment dosimetry, but only Dm with MRI-based contours was predictive of OS on post-treatment images with a median of 23 months for patients with a supramedian Dm versus 14 months for the others (p = 0.04). CONCLUSION In advanced HCC treated with SIRT, Dm and TNR determined with radiologic contours were predictive of tumor control and OS. This study shows that a rigorous clinical workflow (radiologic contours + registration on scintigraphic images) is feasible and should be prospectively considered for improving therapeutic strategy.
Collapse
Affiliation(s)
- Guillaume Nodari
- Department of Nuclear Medicine, Centre Georges-François Leclerc, Dijon, France.
| | - Romain Popoff
- Department of Nuclear Medicine, Centre Georges-François Leclerc, Dijon, France.,ImViA Laboratory, IFTIM Team, EA 7535, University of Burgundy, Dijon, France
| | - Jean Marc Riedinger
- Department of Nuclear Medicine, Centre Georges-François Leclerc, Dijon, France
| | - Olivier Lopez
- Department of Vascular and Interventional Radiology, University Hospital Dijon, Dijon, France
| | - Julie Pellegrinelli
- Department of Vascular and Interventional Radiology, University Hospital Dijon, Dijon, France
| | - Inna Dygai-Cochet
- Department of Nuclear Medicine, Centre Georges-François Leclerc, Dijon, France
| | | | - Benoit Presles
- ImViA Laboratory, IFTIM Team, EA 7535, University of Burgundy, Dijon, France
| | - Olivier Chevallier
- ImViA Laboratory, IFTIM Team, EA 7535, University of Burgundy, Dijon, France.,Department of Vascular and Interventional Radiology, University Hospital Dijon, Dijon, France
| | - Sophie Gehin
- Department of Vascular and Interventional Radiology, University Hospital Dijon, Dijon, France
| | - Matthieu Gallet
- Department of Nuclear Medicine, Centre Georges-François Leclerc, Dijon, France
| | | | - Sylvain Manfredi
- Department of Gastroenterology, University Hospital Dijon, Dijon, France
| | - Romaric Loffroy
- ImViA Laboratory, IFTIM Team, EA 7535, University of Burgundy, Dijon, France.,Department of Vascular and Interventional Radiology, University Hospital Dijon, Dijon, France
| | - Jean Marc Vrigneaud
- Department of Nuclear Medicine, Centre Georges-François Leclerc, Dijon, France.,ImViA Laboratory, IFTIM Team, EA 7535, University of Burgundy, Dijon, France
| | - Alexandre Cochet
- Department of Nuclear Medicine, Centre Georges-François Leclerc, Dijon, France.,ImViA Laboratory, IFTIM Team, EA 7535, University of Burgundy, Dijon, France
| |
Collapse
|
50
|
Plachouris D, Mountris KA, Papadimitroulas P, Spyridonidis T, Katsanos K, Apostolopoulos D, Papathanasiou N, Hazle JD, Visvikis D, Kagadis GC. Clinical Evaluation of a Three-Dimensional Internal Dosimetry Technique for Liver Radioembolization with 90Y Microspheres Using Dose Voxel Kernels. Cancer Biother Radiopharm 2021; 36:809-819. [PMID: 33656372 DOI: 10.1089/cbr.2020.4554] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/24/2022] Open
Abstract
Background: The purpose of this study was to develop a rapid, reliable, and efficient tool for three-dimensional (3D) dosimetry treatment planning and post-treatment evaluation of liver radioembolization with 90Y microspheres, using tissue-specific dose voxel kernels (DVKs) that can be used in everyday clinical practice. Materials and Methods: Two tissue-specific DVKs for 90Y were calculated through Monte Carlo (MC) simulations. DVKs for the liver and lungs were generated, and the dose distribution was compared with direct MC simulations. A method was developed to produce a 3D dose map by convolving the calculated DVKs with the activity biodistribution derived from clinical single-photon emission computed tomography (SPECT) or positron emission tomography (PET) images. Image registration for the SPECT or PET images with the corresponding computed tomography scans was performed before dosimetry calculation. The authors first compared the DVK convolution dosimetry with a direct full MC simulation on an XCAT anthropomorphic phantom. They then tested it in 25 individual clinical cases of patients who underwent 90Y therapy. All MC simulations were carried out using the GATE MC toolkit. Results: Comparison of the measured absorbed dose using tissue-specific DVKs and direct MC simulation on 25 patients revealed a mean difference of 1.07% ± 1.43% for the liver and 1.03% ± 1.21% for the tumor tissue, respectively. The largest difference between DVK convolution and full MC dosimetry was observed for the lung tissue (10.16% ± 1.20%). The DVK statistical uncertainty was <0.75% for both media. Conclusions: This semiautomatic algorithm is capable of performing rapid, accurate, and efficient 3D dosimetry. The proposed method considers tissue and activity heterogeneity using tissue-specific DVKs. Furthermore, this method provides results in <1 min, making it suitable for everyday clinical practice.
Collapse
Affiliation(s)
- Dimitris Plachouris
- 3DMI Research Group, Department of Medical Physics, School of Medicine, University of Patras, Rion, Greece
| | - Konstantinos A Mountris
- Department of Electrical Engineering, Aragon Institute of Engineering Research, IIS Aragon, University of Zaragoza, Zaragoza, Spain
| | | | - Trifon Spyridonidis
- Department of Nuclear Medicine, School of Medicine, University of Patras, Rion, Greece
| | | | | | | | - John D Hazle
- Department of Imaging Physics, The University of Texas MD Anderson Cancer Center, Houston, Texas, USA
| | | | - George C Kagadis
- 3DMI Research Group, Department of Medical Physics, School of Medicine, University of Patras, Rion, Greece.,Department of Imaging Physics, The University of Texas MD Anderson Cancer Center, Houston, Texas, USA
| |
Collapse
|