Deshmukh P, Dhatrak P. Evaluating the Feasibility of Short Dental Implants as Alternatives to Long Dental Implants in Mandibular Bone: A Finite Element Study. J Biomed Mater Res B Appl Biomater 2024; 112:e35481. [PMID: 39213170 DOI: 10.1002/jbm.b.35481] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/27/2024] [Revised: 08/01/2024] [Accepted: 08/14/2024] [Indexed: 09/04/2024]
Abstract
This study uses finite element analysis to investigate the potential application of shorter dental implants as a substitute for longer implants in the lower jaw (mandible). FEA allows the evaluation of the stress patterns around the implant-bone interface, a critical factor for successful osseointegration. Ten models were generated, encompassing five long (L1-L5) and five short implant models (S1-S5) with variations in diameter and length. Hypermesh software was utilized to meticulously prepare the FEA models, ensuring accurate mesh generation. The FEA simulations were conducted under four distinct loading scenarios (100 N occlusal load, 40 N lateral load, 100 N oblique at 30°, and 100 N oblique at 45°) to realistically mimic the forces exerted during biting, using an ABAQUS CAE solver. The results revealed that the von Mises stress generated within the short implant models was demonstrably lower compared to their long implants. Additionally, a significant drop in stress was observed with increasing the diameter of the short implants, to a certain diameter range. These findings suggest the potential for successful substitution of long implant model L4 with short implant model S4 due to the demonstrably lower stress values achieved. Furthermore, the data indicates the possibility of utilizing short implant models S3 and S5 as alternatives to long implant models L3 and L5, respectively. These observations hold significant promise for evaluating the feasibility of replacing long implants with shorter variants, potentially leading to a reduction in implant-related failures.
Collapse
Affiliation(s)
- Prathamesh Deshmukh
- Department of Mechanical Engineering, Dr. Vishwanath Karad MIT World Peace University, Pune, India
| | - Pankaj Dhatrak
- Department of Mechanical Engineering, Dr. Vishwanath Karad MIT World Peace University, Pune, India
| |
Collapse
|
2
|
Anniwaer A, Muhetaer A, Yin Z, Zhu J, Jin C, Huang C. Influence of prosthetic index structures and implant materials on stress distribution in implant restorations: a three-dimensional finite element analysis. BMC Oral Health 2024; 24:901. [PMID: 39107754 PMCID: PMC11304626 DOI: 10.1186/s12903-024-04680-1] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/14/2024] [Accepted: 07/29/2024] [Indexed: 08/10/2024] Open
Abstract
BACKGROUND Mechanical complications affect the stability of implant restorations and are a key concern for clinicians, especially with the frequent introduction of new implant designs featuring various structures and materials. This study evaluated the effect of different prosthetic index structure types and implant materials on the stress distribution of implant restorations using both in silico and in vitro methods. METHODS Four finite element analysis (FEA) models of implant restorations were created, incorporating two prosthetic index structures (cross-fit (CF) and torc-fit (TF)) and two implant materials (titanium and titanium-zirconium). A static load was applied to each group. An in vitro study using digital image correlation (DIC) with a research scenario identical to that of the FEA was conducted for validation. The primary strain, sensitivity index, and equivalent von Mises stress were used to evaluate the outcomes. RESULTS Changing the implant material from titanium to titanium-zirconium did not significantly affect the stress distribution or maximum stress value of other components, except for the implant itself. In the CF group, implants with a lower elastic modulus increased the stress on the screw. The TF group showed better stress distribution on the abutment and a lower stress value on the screw. The TF group demonstrated similar sensitivity for all components. DIC analysis revealed significant differences between TF-TiZr and CF-Ti in terms of the maximum (P < 0.001) and minimum principal strains (P < 0.05) on the implants and the minimum principal strains on the investment materials in both groups (P < 0.001). CONCLUSIONS Changes in the implant material significantly affected the maximum stress of the implant. The TF group exhibited better structural integrity and reliability.
Collapse
Affiliation(s)
- Annikaer Anniwaer
- State Key Laboratory of Oral & Maxillofacial Reconstruction and Regeneration, Key Laboratory of Oral Biomedicine Ministry of Education, Hubei Key Laboratory of Stomatology, School & Hospital of Stomatology, Wuhan University, #237 Luoyu Road, Hongshan District, Wuhan, 430079, China
| | - Aihemaiti Muhetaer
- State Key Laboratory of Oral & Maxillofacial Reconstruction and Regeneration, Key Laboratory of Oral Biomedicine Ministry of Education, Hubei Key Laboratory of Stomatology, School & Hospital of Stomatology, Wuhan University, #237 Luoyu Road, Hongshan District, Wuhan, 430079, China
| | - Zhengrong Yin
- State Key Laboratory of Oral & Maxillofacial Reconstruction and Regeneration, Key Laboratory of Oral Biomedicine Ministry of Education, Hubei Key Laboratory of Stomatology, School & Hospital of Stomatology, Wuhan University, #237 Luoyu Road, Hongshan District, Wuhan, 430079, China
| | - Jiakang Zhu
- State Key Laboratory of Oral & Maxillofacial Reconstruction and Regeneration, Key Laboratory of Oral Biomedicine Ministry of Education, Hubei Key Laboratory of Stomatology, School & Hospital of Stomatology, Wuhan University, #237 Luoyu Road, Hongshan District, Wuhan, 430079, China
| | - Chunxiao Jin
- State Key Laboratory of Oral & Maxillofacial Reconstruction and Regeneration, Key Laboratory of Oral Biomedicine Ministry of Education, Hubei Key Laboratory of Stomatology, School & Hospital of Stomatology, Wuhan University, #237 Luoyu Road, Hongshan District, Wuhan, 430079, China
| | - Cui Huang
- State Key Laboratory of Oral & Maxillofacial Reconstruction and Regeneration, Key Laboratory of Oral Biomedicine Ministry of Education, Hubei Key Laboratory of Stomatology, School & Hospital of Stomatology, Wuhan University, #237 Luoyu Road, Hongshan District, Wuhan, 430079, China.
| |
Collapse
|
3
|
Puengpaiboon U, Rattanapan N, Pasam VK, Sukjamsri C. Finite Element Analysis of Anterior Implant-Supported Restorations with Different CAD-CAM Restorative Materials. Eur J Dent 2024. [PMID: 38744334 DOI: 10.1055/s-0044-1785532] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 05/16/2024] Open
Abstract
OBJECTIVES Due to the lack of literature concerning the selection of crown materials for the restoration of anterior teeth, this study aimed to investigate the effects of six distinct computer-aided design and computer-aided manufacturing (CAD-CAM) crown materials on stress and strain distribution within implant-supported maxillary central incisor restorations, employing finite element analysis (FEA). Furthermore, a comparative analysis was conducted between models that incorporated adjacent natural teeth and those that did not, intending to guide the selection of the most suitable modeling approach. MATERIALS AND METHODS Crown materials, including Lava Ultimate, Enamic, Emax CAD, Suprinity, Celtra Duo, and Cercon xt ML, were the subjects of the investigation. FEA models incorporating Coulomb friction were developed. These models were subjected to an oblique load, simulating the average maximum bite force experienced by anterior teeth. The potential for failure in titanium implant components and the prosthesis crown was evaluated through von Mises and principal stress, respectively. Furthermore, the failure of crestal bone was assessed through principal strain values. STATISTICAL ANALYSIS Stress values for each implant component and strain values of the bone were extracted from the models. To assess the impact of the six groups of crown materials, Kruskal-Wallis analysis of variance and post-hoc comparisons were conducted. Additionally, a statistical comparison between the two groups with Lava Ultimate and Cercon xt ML was performed using the Mann-Whitney U test to determine the difference in the two modeling approaches. RESULTS Higher crown material stiffness led to decreased stress in the abutment, fixture, and retaining screw, along with reduced strain in the surrounding bone. However, the decrease in stress and strain values became less significant with increasing crown stiffness. Additionally, the model with adjacent teeth showed significantly lower stress and strain concentrations compared to the model without adjacent teeth. CONCLUSION Crowns with a high elastic modulus were the optimal choice for anterior teeth restoration. Constructing FEA models with adjacent teeth was highly recommended to gain a deeper understanding of the mechanical behavior of dental implant restorations.
Collapse
Affiliation(s)
- Usanee Puengpaiboon
- Department of General Dentistry, Faculty of Dentistry, Srinakharinwirot University, Bangkok, Thailand
| | - Nichapat Rattanapan
- Department of Biomedical Engineering, Faculty of Engineering, Srinakharinwirot University, Nakhon Nayok, Thailand
| | - Vamsi Krishna Pasam
- Department of Mechanical Engineering, National Institute of Technology Warangal, Warangal, Telangana, India
| | - Chamaiporn Sukjamsri
- Department of Biomedical Engineering, Faculty of Engineering, Srinakharinwirot University, Nakhon Nayok, Thailand
| |
Collapse
|
4
|
Abdoli Z, Mohammadi B, Karimi HR. On the fatigue life of dental implants: Numerical and experimental investigation on configuration effect. Med Eng Phys 2024; 123:104078. [PMID: 38365331 DOI: 10.1016/j.medengphy.2023.104078] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/15/2023] [Revised: 11/10/2023] [Accepted: 12/03/2023] [Indexed: 02/18/2024]
Abstract
Dental implants have seen widespread and successful use in recent years. Given their long-term application and the critical role of geometry in determining fracture and fatigue characteristics, fatigue assessments are of utmost importance for implant systems. In this study, nine dental implant system samples were subjected to testing in accordance with ISO 14801 standards. The tests included static evaluations to assess ultimate loads and fatigue tests conducted under loads of 270 N and 230 N at a frequency of 15 Hz, aimed at identifying fatigue failure locations and fatigue life. Fatigue life predictions and related calculations were carried out using Fe-safe software. The initial model featured a 22° angle for both the fixture and abutment. Subsequently, variations in abutment angles at 21° and 23° were considered while keeping the fixture angle at 22°. In the next phase, the fixture and abutment angles were set as identical, at 21° and 23°. The results unveiled that when the angles of the abutment and fixture matched, stress values decreased, and fatigue life increased. Conversely, models featuring abutment angles of 21° and 23°, with a 22° angle for the fixture, led to a 49.1 % increase in stress and a 36.9 % decrease in fatigue life compared to the primary model. Notably, in the case of the implant with a 23° angle for both abutment and fixture, the fatigue life reached its highest value at 10 million cycles. Conversely, the worst-case scenario was observed in the implant with a 21° abutment angle and a 23° fixture angle, with a fatigue life of 5.49 million cycles.
Collapse
Affiliation(s)
- Zahrae Abdoli
- School of Mechanical Engineering, Iran University of Science and Technology, Tehran, Iran
| | - Bijan Mohammadi
- School of Mechanical Engineering, Iran University of Science and Technology, Tehran, Iran.
| | - Hamid Reza Karimi
- School of Civil Engineering, Iran University of Science and Technology, Tehran, Iran
| |
Collapse
|
5
|
Wu W, Song L, Liu J, Du L, Zhang Y, Chen Y, Tang Z, Shen M. Finite element analysis of the angle range in trans-inferior alveolar nerve implantation at the mandibular second molar. BMC Oral Health 2023; 23:928. [PMID: 38007495 PMCID: PMC10676576 DOI: 10.1186/s12903-023-03641-4] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/18/2023] [Accepted: 11/08/2023] [Indexed: 11/27/2023] Open
Abstract
BACKGROUND Trans- inferior alveolar nerve (IAN) implantation technique was wildly used while the potential appropriate angle range in which the residual alveolar bone can bear the stress without absorption are currently unclear. This study aimed to evaluate the stress distribution pattern of the interface between bone and implant by finite element analysis (FEA) to determine the appropriate range of the implant tilt angle. METHODS Cone beam computed tomography (CBCT) images of 120 patients with missing mandibular second molars and vertical bone height < 9 mm in the edentulous area were selected. The distances from the mandibular nerve canal to the buccal cortex, the lingual cortex and the alveolar ridge crest were measured by using a combination of software. The angular ranges of the buccal-lingual inclination of simulated trans-IAN implants were measured and three-dimensional finite element models were constructed in the mandibular second molar area according to the differences of the inclination angles. A vertical load (200N) was then applied to analyze the biomechanical conditions of the implant-bone interface during median occlusion. RESULTS The distance at the second molar from the nerve canal to the buccal cortex, lingual cortex and alveolar crest were 6.861 ± 1.194 mm, 2.843 ± 0.933 mm and 7.944 ± 0.77 mm. Trans-IAN implantation was feasible in 73.33% of patients. The minimum angle and maximum angles of the buccal-lingual inclination of the simulated implant were 19.135 ± 6.721° and 39.282 ± 6.581°. When a vertical static load of 200N was applied, the tensile stress in cortical bone gradually increased with the increase of the implant tilt angle. When the inclination angle reached 30°, the tensile stress (105.9 MPa) exceeded the yield strength (104 MPa) of cortical bone. Compared with the conventional implants, the stress peak value of the vertical ultra-short implant in cortical bone was greater than the stress peak value of the conventional implants at 10°(79.81 MPa) and 20°(82.83 MPa) and was smaller than the stress of the implant at 30°(105.9 MPa) and 40°(107.8 MPa). Therefore, when the bone mass allows, conventional-length implants should be selected whenever possible, and an operative range of the trans-IAN implantation in the mandibular second molar could be retained with an inclination angle of < 30°. CONCLUSIONS The mandibular nerve canal at the mandibular second molar was obviously biased to the lingual side, which ensured sufficient bone mass at the buccal side. In most patients with severe mandibular atrophy, it was possible to maintain a safe distance from the nerve canal with conventional-length implants via the trans-IAN implantation technique.
Collapse
Affiliation(s)
- Wenli Wu
- Jiangsu Province Key Laboratory of Oral Diseases, Nanjing Medical University, Nanjing, 210029, China
| | - Liangyue Song
- Jiangsu Province Key Laboratory of Oral Diseases, Nanjing Medical University, Nanjing, 210029, China
| | - Jinming Liu
- Jiangsu Province Key Laboratory of Oral Diseases, Nanjing Medical University, Nanjing, 210029, China
| | - Lingyi Du
- Jiangsu Province Key Laboratory of Oral Diseases, Nanjing Medical University, Nanjing, 210029, China
| | - Yuhang Zhang
- Jiangsu Province Key Laboratory of Oral Diseases, Nanjing Medical University, Nanjing, 210029, China
| | - Yingying Chen
- Jiangsu Province Key Laboratory of Oral Diseases, Nanjing Medical University, Nanjing, 210029, China
| | - Zichun Tang
- Jiangsu Province Key Laboratory of Oral Diseases, Nanjing Medical University, Nanjing, 210029, China.
- The Affiliated Stomatological Hospital of Soochow University, Suzhou Stomatological Hospital, Suzhou, 215000, China.
| | - Ming Shen
- Jiangsu Province Key Laboratory of Oral Diseases, Nanjing Medical University, Nanjing, 210029, China.
- Jiangsu Province Engineering Research Center of Stomatological Translational Medicine, Nanjing Medical University, Nanjing, 210029, China.
- Department of General Dentistry, Affiliated Hospital of Stomatology, Nanjing Medical University, Nanjing, 210029, China.
| |
Collapse
|
6
|
Anitua E, Eguia A, Alkhraisat MH. Extra-short implants (≤ 6.5 mm in length) in atrophic and non-atrophic sites to support screw-retained full-arch restoration: a retrospective clinical study. Int J Implant Dent 2023; 9:29. [PMID: 37702800 PMCID: PMC10499764 DOI: 10.1186/s40729-023-00499-7] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/26/2023] [Accepted: 09/05/2023] [Indexed: 09/14/2023] Open
Abstract
PURPOSE Increasing scientific evidence support extending the application of short dental implants to non-atrophic dental arches. The purpose of this study has been the evaluation of extra-short implants (≤ 6.5 mm in length) that were placed in atrophic and non-atrophic anatomical sites to support the same prosthesis. METHODS For that, a retrospective study was conducted by including complete dentures that were solely supported by extra-short implants in the maxilla and/or the mandible. Clinical data about patients, implants, anatomy, and prosthesis were obtained. Statistical analysis was performed to assess implant- and prosthesis-survival, changes in the marginal bone level and prosthetic complications. RESULTS A total of 87 implants in 15 screw-retained complete dentures were assessed. None of the prostheses nor the extra-short implant failed during the follow-up of 27.2 ± 15.4 months. The changes in the mesial and distal marginal bone level were + 0.15 ± 0.51 mm and + 0.11 ± 0.50 mm, respectively. Comparing the implants according to the availability of sufficient bone to place longer implants, indicated the absence of significant differences in the changes of the mesial marginal bone level. However, the changes in the distal marginal bone level showed a statistically significant difference in favor of implants that were placed in non-atrophic sites. Two events of screw loosening were reported that were resolved by retightening the screws. CONCLUSIONS Implant- and prosthesis-related outcomes support the use of extra-short implants in atrophic and non-atrophic site to support complete prosthesis.
Collapse
Affiliation(s)
- Eduardo Anitua
- Private Practice in Oral Implantology, Clínica Eduardo Anitua Foundation, C/ Jose Maria Cagigal 19, 01007, Vitoria, Spain.
- University Institute for Regenerative Medicine and Oral Implantology, UIRMI (UPV/EHU-Fundación Eduardo Anitua), Vitoria, Spain.
- BTI Biotechnology Institute, Vitoria, Spain.
| | - Asier Eguia
- University Institute for Regenerative Medicine and Oral Implantology, UIRMI (UPV/EHU-Fundación Eduardo Anitua), Vitoria, Spain
- University of the Basque Country UPV/EHU, Leioa (Bizkaia), Spain
| | - Mohammad Hamdan Alkhraisat
- University Institute for Regenerative Medicine and Oral Implantology, UIRMI (UPV/EHU-Fundación Eduardo Anitua), Vitoria, Spain
- BTI Biotechnology Institute, Vitoria, Spain
| |
Collapse
|
7
|
Qin S, Gao Z. Comparative evaluation of short or standard implants with different prosthetic designs in the posterior mandibular region: a three-dimensional finite element analysis study. Comput Methods Biomech Biomed Engin 2023; 26:1499-1509. [PMID: 36125258 DOI: 10.1080/10255842.2022.2124859] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/05/2022] [Revised: 08/29/2022] [Accepted: 09/11/2022] [Indexed: 11/03/2022]
Abstract
The purpose of this study is to evaluate the stress distribution of splinted or nonsplinted restorations supported by 2 short or 2 standard dental implants in the mandibular molar region using three-dimensional finite element analysis. Two standard implants (4.8 × 10mm) were placed in the mandibular molar area. Two short implants (4.8 × 6 mm) were located in the mandibular molar atrophied area. Implant-supported prostheses were simulated with splinted or nonsplinted crowns design. Vertical load of 200 N and oblique load of 100 N were applied on the central fossa and the buccal cusps. Evaluation of stress distribution in implants and peri-implant cortical bone using the finite element analysis software (Ansys, Version 2020, R2), a multipurpose computer design program. The maximum principal stress of cortical bone around the implants was higher in nonsplinted crowns when compared to splinted crowns. The stress concentration of cortical bone surrounding implants increased as the implant length decreased either splinted crowns or nonsplinted crowns. The short implants with nonsplinted crowns showed lower stresses when compared to standard implants with nonsplinted crowns. The results suggest that the nonsplinted prostheses supported by short dental implants might be considered in the molar area of the atrophic mandible.
Collapse
Affiliation(s)
- Siqi Qin
- Department of Stomatology, The Second Affiliated Hospital of Chongqing Medical University, Chongqing, People's Republic of China
| | - Zhi Gao
- Department of Stomatology, The Second Affiliated Hospital of Chongqing Medical University, Chongqing, People's Republic of China
| |
Collapse
|
8
|
Heimes D, Becker P, Pabst A, Smeets R, Kraus A, Hartmann A, Sagheb K, Kämmerer PW. How does dental implant macrogeometry affect primary implant stability? A narrative review. Int J Implant Dent 2023; 9:20. [PMID: 37405709 DOI: 10.1186/s40729-023-00485-z] [Citation(s) in RCA: 5] [Impact Index Per Article: 5.0] [Reference Citation Analysis] [Abstract] [Key Words] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/03/2023] [Accepted: 06/21/2023] [Indexed: 07/06/2023] Open
Abstract
PURPOSE The macrogeometry of a dental implant plays a decisive role in its primary stability. A larger diameter, a conical shape, and a roughened surface increase the contact area of the implant with the surrounding bone and thus improve primary stability. This is considered the basis for successful implant osseointegration that different factors, such as implant design, can influence. This narrative review aims to critically review macro-geometric features affecting the primary stability of dental implants. METHODS For this review, a comprehensive literature search and review of relevant studies was conducted based on formulating a research question, searching the literature using keywords and electronic databases such as PubMed, Embase, and Cochrane Library to search for relevant studies. These studies were screened and selected, the study quality was assessed, data were extracted, the results were summarized, and conclusions were drawn. RESULTS The macrogeometry of a dental implant includes its surface characteristics, size, and shape, all of which play a critical role in its primary stability. At the time of placement, the initial stability of an implant is determined by its contact area with the surrounding bone. Larger diameter and a conical shape of an implant result in a larger contact area and better primary stability. But the linear relationship between implant length and primary stability ends at 12 mm. CONCLUSIONS Several factors must be considered when choosing the ideal implant geometry, including local factors such as the condition of the bone and soft tissues at the implant site and systemic and patient-specific factors such as osteoporosis, diabetes, or autoimmune diseases. These factors can affect the success of the implant procedure and the long-term stability of an implant. By considering these factors, the surgeon can ensure the greatest possible therapeutic success and minimize the risk of implant failure.
Collapse
Affiliation(s)
- Diana Heimes
- Department of Oral and Maxillofacial Surgery, University Medical Center Mainz, Augustusplatz 2, 55131, Mainz, Germany.
| | - Philipp Becker
- Department of Oral and Maxillofacial Surgery, University Medical Center Mainz, Augustusplatz 2, 55131, Mainz, Germany
- Department of Oral and Maxillofacial Surgery, Federal Armed Forces Hospital, Rübenacherstraße 170, 56072, Koblenz, Germany
| | - Andreas Pabst
- Department of Oral and Maxillofacial Surgery, University Medical Center Mainz, Augustusplatz 2, 55131, Mainz, Germany
- Department of Oral and Maxillofacial Surgery, Federal Armed Forces Hospital, Rübenacherstraße 170, 56072, Koblenz, Germany
| | - Ralf Smeets
- Department of Oral and Maxillofacial Surgery, University Medical Center Hamburg-Eppendorf, Martinistraße 52, 20246, Hamburg, Germany
- Department of Oral and Maxillofacial Surgery, Division of "Regenerative Orofacial Medicine", University Medical Center Hamburg-Eppendorf, Hamburg, Germany
| | - Annika Kraus
- Department of Prosthetic Dentistry, University Medical Center Mainz, Augustusplatz 2, 55131, Mainz, Germany
| | - Amely Hartmann
- Department of Oral and Maxillofacial Surgery, University Medical Center Mainz, Augustusplatz 2, 55131, Mainz, Germany
- Private Practice for Oral Surgery, Echterdinger Straße 7, 70794, Filderstadt, Germany
| | - Keyvan Sagheb
- Department of Oral and Maxillofacial Surgery, University Medical Center Mainz, Augustusplatz 2, 55131, Mainz, Germany
| | - Peer W Kämmerer
- Department of Oral and Maxillofacial Surgery, University Medical Center Mainz, Augustusplatz 2, 55131, Mainz, Germany
| |
Collapse
|
9
|
Nie H, Tang Y, Yang Y, Wu W, Zhou W, Liu Z. Influence of a new abutment design concept on the biomechanics of peri-implant bone, implant components, and microgap formation: a finite element analysis. BMC Oral Health 2023; 23:277. [PMID: 37170117 PMCID: PMC10176806 DOI: 10.1186/s12903-023-02989-x] [Citation(s) in RCA: 3] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/27/2023] [Accepted: 04/25/2023] [Indexed: 05/13/2023] Open
Abstract
BACKGROUND A new two-piece abutment design consisting of an upper prosthetic component and tissue-level base has been introduced; however, the biomechanical behavior of such a design has not been documented. This study aimed to investigate the effect of a two-piece abutment design on the stress in the implant components and surrounding bone, as well as its influence on microgap formation. METHODS To simulate the implant models in the mandibular left first molar area, we established nine experimental groups that included three bone qualities (type II, III, and IV) and three implant-abutment designs (internal bone level, tissue level, and a two-piece design). After the screw was preloaded, the maximum occlusal (600 N) and masticatory (225 N) forces were established. Finite element analysis was performed to analyze the maximum and minimum principal stresses on the peri-implant bone; the von Mises stresses in the implants, abutments, bases, and screws, and the microgaps at the implant-abutment, implant-base, and base-abutment interfaces. RESULTS For all three loading methods, the two-piece abutment design and bone-level connection exhibited similarities in the maximum and minimum principal stresses in the peri-implant bone. The von Mises stresses in both screws and bases were greater for the two-piece design than for the other connection types. The smallest microgap was detected in the tissue-level connection; the largest was observed at the implant-base interface in the two-piece design. CONCLUSIONS The present study found no evidence that the abutment design exerts a significant effect on peri-implant bone stress. However, the mechanical effects associated with the base and screws should be noted when using a two-piece abutment design. The two-piece abutment design also had no advantage in eliminating the microgap.
Collapse
Affiliation(s)
- Huimin Nie
- Department of Implant Dentistry, Binzhou Medical University Affiliated Yantai Stomatological Hospital, No. 19, Beima Road, Zhifu District, Yantai, 264000, China
| | - Yantai Tang
- Department of Implant Dentistry, Binzhou Medical University Affiliated Yantai Stomatological Hospital, No. 19, Beima Road, Zhifu District, Yantai, 264000, China
| | - Yan Yang
- Department of Implant Dentistry, Binzhou Medical University Affiliated Yantai Stomatological Hospital, No. 19, Beima Road, Zhifu District, Yantai, 264000, China
| | - Weijie Wu
- University of Science and Technology Beijing, Beijing, 100000, China
| | - Wenjuan Zhou
- Department of Implant Dentistry, Binzhou Medical University Affiliated Yantai Stomatological Hospital, No. 19, Beima Road, Zhifu District, Yantai, 264000, China.
| | - Zhonghao Liu
- Department of Implant Dentistry, Binzhou Medical University Affiliated Yantai Stomatological Hospital, No. 19, Beima Road, Zhifu District, Yantai, 264000, China
| |
Collapse
|
10
|
Wagner C, Herberg S, Bourauel C, Stark H, Dörsam I. Biomechanical analysis of different fixed dental restorations on short implants: a finite element study. BIOMED ENG-BIOMED TE 2023:bmt-2022-0414. [PMID: 36795430 DOI: 10.1515/bmt-2022-0414] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/23/2022] [Accepted: 02/02/2023] [Indexed: 02/17/2023]
Abstract
OBJECTIVES Although the use of short implants is becoming more common for patients with atrophic alveolar ridges, their use is still quite limited. This is due to the lack of data of long-term survival compared to standard-length implants. The aim of this study was to determine the load in the bone and implant system with different superstructures. METHODS Three kinds of prosthetic restorations were created on short implants based on CT-Data. Two short implants with different macro-geometries were used. The implants were inserted in idealised posterior lower mandibular segments and afterwards restored with a crown, a double splinted crown, and a bridge. RESULTS The analysis was performed under load of 300 N either divided between a mesial and distal point or as a point load on the pontic/mesial crown. The different design of the implant systems had a noticeable influence on the stress in the cortical bone, in the implant system, and the displacement of the superstructure as well. CONCLUSIONS Compared with implants of standard length, higher stresses were observed, which can lead early failure of the implant during the healing period or a late cervical bone resorption. Precise indications are essential for short implants to avoid the failure of short implants.
Collapse
Affiliation(s)
- Christian Wagner
- Department of Prosthetic Dentistry, Preclinical Education and Materials Science, Dental School, University of Bonn Bonn, Germany
| | - Samira Herberg
- Department of Prosthetic Dentistry, Preclinical Education and Materials Science, Dental School, University of Bonn Bonn, Germany
| | | | - Helmut Stark
- Department of Prosthetic Dentistry, Preclinical Education and Materials Science, Dental School, University of Bonn Bonn, Germany
| | - Istabrak Dörsam
- Department of Prosthetic Dentistry, Preclinical Education and Materials Science, Dental School, University of Bonn Bonn, Germany.,Oral Technology, University of Bonn Bonn, Germany
| |
Collapse
|
11
|
The evaluation of stress on bone level and tissue level short implants: A Finite Element Analysis (FEA) study. JOURNAL OF STOMATOLOGY, ORAL AND MAXILLOFACIAL SURGERY 2023; 124:101298. [PMID: 36179771 DOI: 10.1016/j.jormas.2022.09.019] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 09/23/2022] [Accepted: 09/26/2022] [Indexed: 11/23/2022]
Abstract
PURPOSE This study aimed to evaluate the difference between the stress level and distribution around the BL and TL short implants, and their surrounding structures, using finite element analysis. METHODS Two different study models were constructed: BL model and TL model. Two dental implant systems (ITI (Straumann, Waldenburg, Switzerland) and NTA Short) with a diameter of 4.1 mm and 4 mm and with a length of 6 mm were used in this study. In each model, implants were placed in the mandibular 1st molar region. The von Mises stress and maximum principal (tensile) and minimum principal (compressive) stresses were evaluated. RESULTS The highest stress values recorded in the BL implants (von Mises: 342.77 MPa), in the peri‑implant bone around the BL implants (maximum principal stress: 114.1 MPa), as a result of oblique loading, and overall stress values were found to be higher in the BL model. However, these measured values appeared to be low to cause a fracture, when considering the yield strengths of the materials and bone. CONCLUSIONS The stress values were higher in the BL model, but not high enough to cause failure. Short implants could be an effective method of treatment for patients unsuitable for advanced surgical techniques.
Collapse
|
12
|
Anitua E, Alkhraisat MH, Eguia A. Single-crown restorations in premolar-molar regions: short (≤ 6.5) vs longer implants: retrospective cohort study. Int J Implant Dent 2022; 8:40. [PMID: 36192573 PMCID: PMC9530083 DOI: 10.1186/s40729-022-00438-y] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/07/2022] [Accepted: 09/08/2022] [Indexed: 11/25/2022] Open
Abstract
Purpose To compare the survival, changes in marginal bone level and prosthetic complications rate of short (≤ 6.5 mm) and longer implants (≥ 7.5) supporting a single-crown restoration in the maxillary/mandibular premolar or molar region. Methods This cohort study was conducted following the STROBE statement recommendations for observational studies. Clinical outcomes of 88 short implants in 78 patients and 88 long implants in 88 patients were examined. All the implants had been placed by the same surgeon and restored following the same prosthetic concept; using a transepithelial abutment (intermediate abutment) and a screw retained restoration. Results All the implants were in function after the follow-up period since insertion (median: 31 months; range 11 to 84 for SiG vs median: 35 months; range: 6–117 for CG; p = 0.139). No statistical differences (p = 0.342) were observed related to prosthetic complications (screw loosening 2/88 vs 5/88 CG, ceramic chipping 1/88 vs 0/88, temporary crown resin chipping 1/88 vs 0/88 for SiG and CG, respectively) or related to marginal bone level (Mesial or Distal MBL ≥ 2 mm in 1/88 implants for SiG vs 3/88 for CG; p = 0.312). Conclusions Within the limitations of this study, no survival differences have been observed between short implants and longer implants in single-crown restorations in posterior maxilla/mandible.
Collapse
Affiliation(s)
- Eduardo Anitua
- Clínica Eduardo Anitua, Jose Maria Cagigal Kalea, 19, 01007, Vitoria-Gazteiz, Álava, Spain. .,BTI-Biotechnology Institute, Vitoria-Gazteiz, Álava, Spain.
| | | | - Asier Eguia
- Clínica Eduardo Anitua, Jose Maria Cagigal Kalea, 19, 01007, Vitoria-Gazteiz, Álava, Spain.,University of the Basque Country UPV/EHU, Leioa, Vizcaya, Spain
| |
Collapse
|
13
|
Kushwah A, Kumar M, Premsagar S, Sharma S, Kumar S, Sailesh T. Analysis of initial stress distribution in palatal bone around the implant in lingual orthodontics for single and double palatal implant systems: a FEM study. Dental Press J Orthod 2022; 27:e2120492. [PMID: 36169494 PMCID: PMC9507026 DOI: 10.1590/2177-6709.27.4.e2120492.oar] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/07/2020] [Accepted: 03/15/2021] [Indexed: 12/02/2022] Open
Abstract
Objective: To analyze and compare the Von Mises stress and principal stress distribution in palatal bone around the palatal implant in lingual orthodontics (LiO) for single and double palatal implant systems with varying lengths of lever arm. Methods: Two groups were assessed: single (Group 1) and double (Group 2) palatal implant systems, which were further divided into two subgroups, based on lever arm length, for analyzing stress in the palatal bone around the implant. Hence, two 3D finite element models of bilateral maxillary first premolar extraction cases were constructed in each system. Lingual brackets (0.018-in slot) were positioned at the center of the clinical crown. In both systems, 150g of retraction force was applied, and ANSYS v. 12.1 software was used to analyze and compare stress in the palatal bone around the palatal implant. Results: In this study, higher stress was observed at the inner threaded interface of cortical bone. Magnitude of Von Mises stress was higher in Group 2 (0.63 MPa and 0.65 MPa) in comparison to Group 1 (0.29 MPa and 0.29 MPa). Similarly, magnitude of principal stress was higher in Group 2, in comparison to Group 1. Higher stress was observed in the apical region of the implant-bone interface of cancellous bone. Conclusion: This study concluded that the Von Misses stress as well as principal stress in the palatal bone were within the optimal limit in both groups. Finally, it can be concluded that both systems (single and double palatal implant) were safe for the patients in clinical use of 150g of retraction force.
Collapse
Affiliation(s)
- Ashish Kushwah
- Institute of Dental Education & Advance Studies, Department of Orthodontics and Dentofacial Orthopaedics, (Gwalior/MP, India)
| | - Mukesh Kumar
- Teerthanker Mahaveer Dental College, Department of Orthodontics and Dentofacial Orthopaedics, (Moradabad/UP, India)
| | - Shruti Premsagar
- ITS Dental College, Department of Orthodontics and Dentofacial Orthopaedics (Greater Noida, UP, India)
| | | | - Sumit Kumar
- Teerthanker Mahaveer Dental College, Department of Orthodontics and Dentofacial Orthopaedics, (Moradabad/UP, India)
| | | |
Collapse
|
14
|
Influence of Implant Tilting and Length on the Biomechanics of Single-Tooth Restoration: A Finite Element Analysis in Atrophic Mandible. Dent J (Basel) 2022; 10:dj10050077. [PMID: 35621530 PMCID: PMC9139222 DOI: 10.3390/dj10050077] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/14/2022] [Revised: 04/19/2022] [Accepted: 04/24/2022] [Indexed: 12/28/2022] Open
Abstract
The aim of the present study is to assess by means of finite element models the effect on bone stresses of implant length and tilting in single-unit implant restorations. The factors that were analyzed in this study were implant length (4.5, 5.5, and 10 mm), implant titling (0, 17°, 30°, and 45°), bone type (0/I, II, and III), and loading (immediate and delayed). An axial load of 200 N was applied to the occlusal surface of the prosthesis at a height of 11 mm and the Von Mises equivalent stress in the bone was analyzed. Finite element analysis indicated that the most determinant factor was implant tilting. Tilting the implant by 17° doubled the Von Mises stress received by bone. The highest increase was in the case of implant tilting at 45° (by 1300%). The use of extra-short implants did not produce a significant increase in Von Mises stress in bone. Moreover, the length of the implant did not affect the stress value in bone types I and II. Based on the obtained results, an axially placed short implant would be a better option than titling a standard-length implant to support a crown restoration in an atrophic mandible from a biomechanical point of view.
Collapse
|
15
|
Sun F, Lv LT, Cheng W, Zhang JL, Ba DC, Song GQ, Lin Z. Effect of Loading Angles and Implant Lengths on the Static and Fatigue Fractures of Dental Implants. MATERIALS (BASEL, SWITZERLAND) 2021; 14:5542. [PMID: 34639935 PMCID: PMC8509834 DOI: 10.3390/ma14195542] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 07/24/2021] [Revised: 09/16/2021] [Accepted: 09/19/2021] [Indexed: 11/16/2022]
Abstract
Mechanical properties play a key role in the failure of dental implants. Dental implants require fatigue life testing before clinical application, but this process takes a lot of time. This study investigated the effect of various loading angles and implant lengths on the static fracture and fatigue life of dental implants. Implants with lengths of 9 mm and 11 mm were prepared. Static fracture tests and dynamic fatigue life tests were performed under three loading angles (30°, 40°, and 50°), and the level arm and bending moment were measured. After that, the fracture morphology and fracture mode of the implant were observed. The results showed that 9 mm length implants have a higher static failure load and can withstand greater bending moments, while 11 mm length implants have a longer fatigue life. In addition, as the loading angle increases, the static strength and bending moment decrease linearly, and the fatigue life shows an exponential decrease at a rate of three times. Increasing the loading angle reduces the time of the implant fatigue test, which may be an effective method to improve the efficiency of the experiment.
Collapse
Affiliation(s)
| | | | | | | | | | | | - Zeng Lin
- Key Laboratory of Implant Device and Interface Science of Liaoning Province, School of Mechanical Engineering and Automation, Northeastern University, Shenyang 110819, China; (F.S.); (L.-T.L.); (W.C.); (J.-L.Z.); (D.-C.B.); (G.-Q.S.)
| |
Collapse
|
16
|
Lin C, Hu H, Zhu J, Wu Y, Rong Q, Tang Z. Influence of sagittal root positions on the stress distribution around custom-made root-analogue implants: a three-dimensional finite element analysis. BMC Oral Health 2021; 21:443. [PMID: 34521397 PMCID: PMC8438997 DOI: 10.1186/s12903-021-01809-4] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/21/2021] [Accepted: 09/07/2021] [Indexed: 11/18/2022] Open
Abstract
Background Stress concentration may cause bone resorption even lead to the failure of implantation. This study was designed to investigate whether a certain sagittal root position could cause stress concentration around maxillary anterior custom-made root-analogue implants via three-dimensional finite element analysis. Methods The von Mises stresses in the bone around implants in different groups were compared by finite element analysis. Six models were constructed and divided into two groups through Geomagic Studio 2012 software. The smooth group included models of unthreaded custom-made implants in Class I, II or III sagittal root positions. The threaded group included models of reverse buttress-threaded implants in the three positions. The von Mises stress distributions and the range of the stresses under vertical and oblique loads of 100 N were analyzed through ANSYS 16.0 software. Results Stress concentrations around the labial lamella area were more prominent in the Class I position than in the Class II and Class III positions under oblique loading. Under vertical loading, the most obvious stress concentration areas were the labial lamella and palatal apical areas in the Class I and Class III positions, respectively. Stress was relatively distributed in the labial and palatal lamellae in the Class II position. The maximum von Mises stresses in the bone around the custom-made root-analogue implants in this study were lower than around traditional implants reported in the literature. The maximum von Mises stresses in this study were all less than 25 MPa in cortical bone and less than 6 MPa in cancellous bone. Additionally, compared to the smooth group, the threaded group showed lower von Mises stress concentration in the bone around the implants. Conclusions The sagittal root position affected the von Mises stress distribution around custom-made root-analogue implants. There was no certain sagittal root position that could cause excessive stress concentration around the custom-made root-analogue implants. Among the three sagittal root positions, the Class II position would be the most appropriate site for custom-made root-analogue implants.
Collapse
Affiliation(s)
- Chunping Lin
- Department of Periodontology, Peking University School and Hospital of Stomatology, National Engineering Laboratory for Digital and Material Technology of Stomatology, Beijing Key Laboratory of Digital Stomatology, Beijing, 100081, China
| | - Hongcheng Hu
- Second Dental Center, Peking University School and Hospital of Stomatology, National Engineering Laboratory for Digital and Material Technology of Stomatology, Beijing Key Laboratory of Digital Stomatology, Beijing, 100101, China
| | - Junxin Zhu
- Second Dental Center, Peking University School and Hospital of Stomatology, National Engineering Laboratory for Digital and Material Technology of Stomatology, Beijing Key Laboratory of Digital Stomatology, Beijing, 100101, China
| | - Yuwei Wu
- Second Dental Center, Peking University School and Hospital of Stomatology, National Engineering Laboratory for Digital and Material Technology of Stomatology, Beijing Key Laboratory of Digital Stomatology, Beijing, 100101, China
| | - Qiguo Rong
- Department of Mechanics and Engineering Science, College of Engineering, Peking University, Beijing, 100871, China.
| | - Zhihui Tang
- Second Dental Center, Peking University School and Hospital of Stomatology, National Engineering Laboratory for Digital and Material Technology of Stomatology, Beijing Key Laboratory of Digital Stomatology, Beijing, 100101, China.
| |
Collapse
|
17
|
Yeğin E, Atala MH. Comparison of CAD/CAM manufactured implant-supported crowns with different analyses. Int J Implant Dent 2020; 6:69. [PMID: 33106916 PMCID: PMC7588579 DOI: 10.1186/s40729-020-00267-x] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/22/2020] [Accepted: 09/17/2020] [Indexed: 11/23/2022] Open
Abstract
Background Present study compared the failure load of CAD/CAM-manufactured implant-supported crowns and the stress distribution on the prosthesis-implant-bone complex with different restoration techniques. Methods The materials were divided into four groups: group L-M: lithium disilicate ceramic (LDS, monolithic), group L-V: LDS ceramic (veneering), group ZL-M: zirconia-reinforced lithium silicate ceramic (ZLS, monolithic), group ZL-V: ZLS ceramic (veneering). Crown restorations were subjected to load-to-failure test (0.5 mm/min). Failure loads of each group were statistically analyzed (two-way ANOVA, post hoc Tukey HSD, α = 0.05). Finite element analysis (FEA) was used to compare the stress distribution of crown restorations. Results Group L-M had the highest failure load (2891.88 ± 410.12 N) with a significant difference from other groups (p < 0.05). Although there was a significant difference between group ZL-M (1750.28 ± 314.96 N) and ZL-V (2202.55 ± 503.14 N), there was no significant difference from group L-V in both groups (2077.37 ± 356.59 N) (p > 0.05). Conclusions The veneer application had opposite effects on ceramics, increased the failure load of ZLS and reduced it for LDS without a statistically significant difference. Both materials are suitable for implant-supported crowns. Different restorative materials did not influence the stress distribution, but monolithic restorations reduced the stress concentration on the implant and bone.
Collapse
Affiliation(s)
- Elif Yeğin
- Department of Prosthodontics, Faculty of Dentistry, Biruni University, Istanbul, Turkey.
| | - Mustafa Hayati Atala
- Department of Prosthodontics, Faculty of Dentistry, Medeniyet University, Istanbul, Turkey
| |
Collapse
|
18
|
Kim JH, Noh G, Hong SJ, Lee H. Biomechanical stress and microgap analysis of bone-level and tissue-level implant abutment structure according to the five different directions of occlusal loads. J Adv Prosthodont 2020; 12:316-321. [PMID: 33149853 PMCID: PMC7604240 DOI: 10.4047/jap.2020.12.5.316] [Citation(s) in RCA: 6] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/13/2020] [Revised: 09/15/2020] [Accepted: 09/22/2020] [Indexed: 11/11/2022] Open
Abstract
PURPOSE The stress distribution and microgap formation on an implant abutment structure was evaluated to determine the relationship between the direction of the load and the stress value. MATERIALS AND METHODS Two types of three-dimensional models for the mandibular first molar were designed: bone-level implant and tissue-level implant. Each group consisted of an implant, surrounding bone, abutment, screw, and crown. Static finite element analysis was simulated through 200 N of occlusal load and preload at five different load directions: 0, 15, 30, 45, and 60°. The von Mises stress of the abutment and implant was evaluated. Microgap formation on the implant-abutment interface was also analyzed. RESULTS The stress values in the implant were as follows: 525, 322, 561, 778, and 1150 MPa in a bone level implant, and 254, 182, 259, 364, and 436 MPa in a tissue level implant at a load direction of 0, 15, 30, 45, and 60°, respectively. For microgap formation between the implant and abutment interface, three to seven-micron gaps were observed in the bone level implant under a load at 45 and 60°. In contrast, a three-micron gap was observed in the tissue level implant under a load at only 60°. CONCLUSION The mean stress of bone-level implant showed 2.2 times higher than that of tissue-level implant. When considering the loading point of occlusal surface and the direction of load, higher stress was noted when the vector was from the center of rotation in the implant prostheses.
Collapse
Affiliation(s)
- Jae-Hoon Kim
- Department of Dental Education, Dental Research Institute, Dental and Life Science Institute, School of Dentistry, Pusan National University, Yangsan, Republic of Korea
| | - Gunwoo Noh
- School of Mechanical Engineering, Kyungpook National University, Daegu, Republic of Korea
| | - Seoung-Jin Hong
- Department of Prosthodontics, Kyung Hee University Dental Hospital, Seoul, Republic of Korea
| | - Hyeonjong Lee
- Department of Prosthodontics, Dental Research Institute, Dental and Life Science Institute, School of Dentistry, Pusan National University, Yangsan, Republic of Korea
| |
Collapse
|
19
|
Effect of Different Implant Designs on Strain and Stress Distribution under Non-Axial Loading: A Three-Dimensional Finite Element Analysis. INTERNATIONAL JOURNAL OF ENVIRONMENTAL RESEARCH AND PUBLIC HEALTH 2020; 17:ijerph17134738. [PMID: 32630294 PMCID: PMC7370002 DOI: 10.3390/ijerph17134738] [Citation(s) in RCA: 21] [Impact Index Per Article: 5.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 05/12/2020] [Revised: 06/20/2020] [Accepted: 06/26/2020] [Indexed: 11/17/2022]
Abstract
Implant design evolved alongside the development of implant therapy. The purpose of this finite element analysis (FEA) study was to analyze the influence of different implant designs on the stress and strain distribution to the implants and surrounding bone. Three implant designs with the same length and diameter were used. The three-dimensional geometry of the bone was simulated with a cortical bone of three different thicknesses and two medullar bone densities: low density (150 Hounsfield units) and high density (850 Hounsfield units). A 30° oblique load of 150 N was applied to the implant restoration. Displacement and stress (von Mises) results were obtained for bone and dental implants. The strain and stress distributions to the bone were higher for the tissue-level implant for all types of bone. The maximum principal strain and stress decreased with an increase in cortical bone thickness for both cancellous bone densities. The distribution of the load was concentrated at the coronal portion of the bone and implants. All implants showed a good distribution of forces for non-axial loads, with higher forces concentrated at the crestal region of the bone–implant interface. Decrease in medullar bone density negatively affects the strain and stress produced by the implants.
Collapse
|
20
|
The Trends of TiZr Alloy Research as a Viable Alternative for Ti and Ti16 Zr Roxolid Dental Implants. COATINGS 2020. [DOI: 10.3390/coatings10040422] [Citation(s) in RCA: 14] [Impact Index Per Article: 3.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 12/26/2022]
Abstract
Despite many discussions about Ti versus Zr, Ti remains the golden standard for dental implants. With the extended use of implants, their rejection in peri-implantitis due to material properties is going to be an important part of oral health problems. Extended use of implants leading to a statistical increase in implant rejection associated with peri-implantitis raises concerns in selecting better implant materials. In this context, starting in the last decade, investigation and use of TiZr alloys as alternatives for Ti in oral dentistry became increasingly more viable. Based on existing new results for Ti16Zr (Roxolid) implants and Ti50Zr alloy behaviour in oral environments, this paper presents the trends of research concerning the electrochemical stability, mechanical, and biological properties of this alloy with treated and untreated surfaces. The surface treatments were mostly performed by anodizing the alloy in various conditions as a non-sophisticated and cheap procedure, leading to nanostructures such as nanopores and nanotubes. The drug loading and release from nanostructured Ti50Zr as an important perspective in oral implant applications is discussed and promoted as well.
Collapse
|