1
|
K K, Karuppudaiyan S, Roy S. Design and evaluation of mechanical strength of multi-material polymeric implants for mandibular reconstruction. Int J Artif Organs 2024:3913988241261817. [PMID: 39066643 DOI: 10.1177/03913988241261817] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 07/30/2024]
Abstract
Reconstruction of mandible implants to address segmental abnormalities is still a challenging task, both in vitro and in vivo. The mechanical strength of the materials used is a critical factor that determines how well bone is regenerated. The reconstruction technique of mandibular abnormalities widely uses polymeric implants. It is critical to evaluate the mechanical resilience under different load cases, including axial, combined, and flexural loading conditions. This study developed implants for mandibular defects using a combination of four materials: polylactic acid (PLA), polyethylene terephthalate glycol (PETG), thermoplastic polyurethane (TPU), and polycaprolactone (PCL), with the aim of mimicking the inherent characteristics of cortical and cancellous bone structures and evaluating their mechanical properties to support bone Osseo integration. The eleven of these combinations of structures result below the micro strain threshold level of <3000 µε, and the five combinations of the structures result in micro strain above the threshold value. The intact bone study results show that the stress under axial, combined, and flexural loading conditions is 27.6, 38.9, and 64.9 MPa, respectively. This study's stress results are lower than those from the intact bone study. The study found that the combinations of PLA and TPU material were most preferred for the cortical and cancellous bone regions of polymeric implants. These materials are also compatible with 3D printing. The results of this study can be used to find multi-material combinations that are strong and flexible.
Collapse
Affiliation(s)
- Kalaithendral K
- Department of Mechanical Engineering, SRM Institute of Science and Technology, Kattankulathur, Tamil Nadu, India
| | - S Karuppudaiyan
- Department of Mechanical Engineering, SRM Institute of Science and Technology, Kattankulathur, Tamil Nadu, India
| | - Sandipan Roy
- Department of Mechanical Engineering, SRM Institute of Science and Technology, Kattankulathur, Tamil Nadu, India
| |
Collapse
|
2
|
Huang X, Zheng L, Zheng D, Li S, Fan Y, Lin Z, Huang S. Studying trabecular bone samples demonstrates a power law relation between deteriorated structure and mechanical properties - a study combining 3D printing with the finite element method. Front Endocrinol (Lausanne) 2023; 14:1061758. [PMID: 37334285 PMCID: PMC10273262 DOI: 10.3389/fendo.2023.1061758] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 10/05/2022] [Accepted: 05/17/2023] [Indexed: 06/20/2023] Open
Abstract
Introduction The bone volume fraction (BV/TV) significantly contributes to the mechanical properties of trabecular bone. However, when studies compare normal trabeculae against osteoporotic trabeculae (in terms of BV/TV decrease), only an "average" mechanical result has been determined because of the limitation that no two trabecular structures are the same and that each unique trabecular structure can be mechanically tested only once. The mathematic relation between individual structural deterioration and mechanical properties during aging or the osteoporosis process has yet to be further clarified. Three-dimensional (3D) printing and micro-CT-based finite element method (μFEM) can assist in overcoming this issue. Methods In this study, we 3D printed structural-identical but BV/TV value-attenuated trabecular bones (scaled up ×20) from the distal femur of healthy and ovariectomized rats and performed compression mechanical tests. Corresponding μFEM models were also established for simulations. The tissue modulus and strength of 3D printed trabecular bones as well as the effective tissue modulus (denoted as Ez) derived from μFEM models were finally corrected by the side-artifact correction factor. Results The results showed that the tissue modulus corrected, strength corrected and Ez corrected exhibited a significant power law function of BV/TV in structural-identical but BV/TV value-attenuated trabecular samples. Discussion Using 3D printed bones, this study confirms the long-known relationship measured in trabecular tissue with varying volume fractions. In the future, 3D printing may help us attain better bone strength evaluations and even personal fracture risk assessments for patients who suffer from osteoporosis.
Collapse
Affiliation(s)
- Xiuhong Huang
- Stomatological Hospital, School of Stomatology, Southern Medical University, Guangzhou, China
| | - Liqin Zheng
- The First Clinical Medical College, Guangzhou University of Chinese Medicine, Guangzhou, Guangdong, China
| | - Desheng Zheng
- The First Clinical Medical College, Guangzhou University of Chinese Medicine, Guangzhou, Guangdong, China
| | - Shaobin Li
- The First Clinical Medical College, Guangzhou University of Chinese Medicine, Guangzhou, Guangdong, China
| | - Yueguang Fan
- Department of Joint Surgery, The First Affiliated Hospital of Guangzhou University of Chinese Medicine, Guangzhou, China
| | - Ziling Lin
- Department of Orthopedic Trauma, The First Affiliated Hospital of Guangzhou University of Chinese Medicine, Guangzhou, Guangdong, China
| | - Shaohong Huang
- Stomatological Hospital, School of Stomatology, Southern Medical University, Guangzhou, China
| |
Collapse
|
3
|
Dairaghi J, Benito Alston C, Cadle R, Rogozea D, Solorio L, Barco CT, Moldovan NI. A dual osteoconductive-osteoprotective implantable device for vertical alveolar ridge augmentation. FRONTIERS IN DENTAL MEDICINE 2023. [DOI: 10.3389/fdmed.2022.1066501] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/06/2023] Open
Abstract
Repair of large oral bone defects such as vertical alveolar ridge augmentation could benefit from the rapidly developing additive manufacturing technology used to create personalized osteoconductive devices made from porous tricalcium phosphate/hydroxyapatite (TCP/HA)-based bioceramics. These devices can be also used as hydrogel carriers to improve their osteogenic potential. However, the TCP/HA constructs are prone to brittle fracture, therefore their use in clinical situations is difficult. As a solution, we propose the protection of this osteoconductive multi-material (herein called “core”) with a shape-matched “cover” made from biocompatible poly-ɛ-caprolactone (PCL), which is a ductile, and thus more resistant polymeric material. In this report, we present a workflow starting from patient-specific medical scan in Digital Imaging and Communications in Medicine (DICOM) format files, up to the design and 3D printing of a hydrogel-loaded porous TCP/HA core and of its corresponding PCL cover. This cover could also facilitate the anchoring of the device to the patient's defect site via fixing screws. The large, linearly aligned pores in the TCP/HA bioceramic core, their sizes, and their filling with an alginate hydrogel were analyzed by micro-CT. Moreover, we created a finite element analysis (FEA) model of this dual-function device, which permits the simulation of its mechanical behavior in various anticipated clinical situations, as well as optimization before surgery. In conclusion, we designed and 3D-printed a novel, structurally complex multi-material osteoconductive-osteoprotective device with anticipated mechanical properties suitable for large-defect oral bone regeneration.
Collapse
|
4
|
Xu S, Zhang S, Ren G, Pan Y, Li J. Optimization of Structural and Processing Parameters for Selective Laser Melting of Porous 316L Bone Scaffolds. MATERIALS (BASEL, SWITZERLAND) 2022; 15:ma15175896. [PMID: 36079277 PMCID: PMC9456604 DOI: 10.3390/ma15175896] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 07/18/2022] [Revised: 08/09/2022] [Accepted: 08/22/2022] [Indexed: 05/03/2023]
Abstract
In the implantation of porous bone scaffolds, good mechanical properties of the scaffold are a prerequisite for the long-term functionality of the implanted scaffolds, which varies according to the structure and the forming process. In this study, the influence of the forming parameters and structure of the Selective Laser Melting (SLM) process on the mechanical properties of 316L stainless steel bone scaffolds was investigated using finite element simulation combined with experimental methods. The mechanism of the influence of the process parameters and structure on the mechanical properties of bone scaffolds was summarized using static compression finite element numerical simulations, compression experiments, hydrodynamic simulations, forming numerical simulations and SLM forming experiments. The results show that the magnitude of residual stress and the distribution of defects under different process parameters had a strong influence on the microstructure and properties of the scaffold, and the residual stress of the Body-Centered Cube (BCC) structure formed at an energy density of 41.7 J/mm3 was significantly reduced, with less surface spheroidization and fewer cracks on the melt pool surface. The smallest grain size of 321 nm was obtained at an energy density of 77.4 J/mm3, while in terms of mechanical properties, the optimization of the structure resulted in an 8.3% increase in yield strength and a reduction in stress concentration. The predictions of stress, deformation, and forming quality during construction with different process parameters, achieved using finite element analysis, are basically in agreement with the experimental results, indicating that the best process parameters for forming BCC structural supports were determined by using finite element simulation combined with experiments; moreover, the distribution and evolution of residual stresses and defects under different process parameters for constructing BCC structures were obtained.
Collapse
Affiliation(s)
- Shubo Xu
- School of Materials Science and Engineering, Shandong Jianzhu University, Jinan 250101, China
- State Key Laboratory of Materials Processing and Die & Mould Technology, Huazhong University of Science and Technology, Wuhan 430074, China
- Correspondence:
| | - Sen Zhang
- School of Materials Science and Engineering, Shandong Jianzhu University, Jinan 250101, China
| | - Guocheng Ren
- School of Materials Science and Engineering, Shandong Jianzhu University, Jinan 250101, China
| | - Yuefei Pan
- School of Materials Science and Engineering, Shandong Jianzhu University, Jinan 250101, China
| | - Jianing Li
- School of Materials Science and Engineering, Shandong Jianzhu University, Jinan 250101, China
| |
Collapse
|
5
|
Multi-objective Shape Optimization of Bone Scaffolds: Enhancement of Mechanical Properties and Permeability. Acta Biomater 2022; 146:317-340. [PMID: 35533924 DOI: 10.1016/j.actbio.2022.04.051] [Citation(s) in RCA: 7] [Impact Index Per Article: 3.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/11/2022] [Revised: 04/05/2022] [Accepted: 04/29/2022] [Indexed: 11/23/2022]
Abstract
Porous scaffolds have recently attracted attention in bone tissue engineering. The implanted scaffolds are supposed to satisfy the mechanical and biological requirements. In this study, two porous structures named MFCC-1 (modified face centered cubic-1) and MFCC-2 (modified face centered cubic-2) are introduced. The proposed porous architectures are evaluated, optimized, and tested to enhance mechanical and biological properties. The geometric parameters of the scaffolds with porosities ranging from 70% to 90% are optimized to find a compromise between the effective Young's modulus and permeability, as well as satisfying the pore size and specific surface area requirements. To optimize the effective Young's modulus and permeability, we integrated a mathematical formulation, finite element analysis, and computational fluid dynamics simulations. For validation, the optimized scaffolds were 3D-printed, tested, and compared with two different orthogonal cylindrical struts (OCS) scaffold architectures. The MFCC designs are preferred to the generic OCS scaffolds from various perspectives: a) the MFCC architecture allows scaffold designs with porosities up to 96%; b) the very porous architecture of MFCC scaffolds allows achieving high permeabilities, which could potentially improve the cell diffusion; c) despite having a higher porosity compared to the OCS scaffolds, MFCC scaffolds improve mechanical performance regarding Young's modulus, stress concentration, and apparent yield strength; d) the proposed structures with different porosities are able to cover all the range of permeability for the human trabecular bones. The optimized MFCC designs have simple architectures and can be easily fabricated and used to improve the quality of load-bearing orthopedic scaffolds. STATEMENT OF SIGNIFICANCE: Porous scaffolds are increasingly being studied to repair large bone defects. A scaffold is supposed to withstand mechanical loads and provide an appropriate environment for bone cell growth after implantation. These mechanical and biological requirements are usually contradicting; improving the mechanical performance would require a reduction in porosity and a lower porosity is likely to reduce the biological performance of the scaffold. Various studies have shown that the mechanical and biological performance of bone scaffolds can be improved by internal architecture modification. In this study, we propose two scaffold architectures named MFCC-1 and MFCC-2 and provide an optimization framework to simultaneously optimize their stiffness and permeability to improve their mechanical and biological performances.
Collapse
|
6
|
Zhou R, Xue H, Wang J, Wang X, Wang Y, Zhang A, Zhang J, Han Q, Zhao X. Improving the Stability of a Hemipelvic Prosthesis Based on Bone Mineral Density Screw Channel and Prosthesis Optimization Design. Front Bioeng Biotechnol 2022; 10:892385. [PMID: 35706507 PMCID: PMC9189365 DOI: 10.3389/fbioe.2022.892385] [Citation(s) in RCA: 4] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/09/2022] [Accepted: 05/16/2022] [Indexed: 11/13/2022] Open
Abstract
In pelvic reconstruction surgery, the hemipelvic prosthesis can cause significant changes in stress distribution due to its high stiffness, and its solid structure is not suitable for osseointegration. The purpose of this study was to identify a novel bone mineral density screw channel and design the structure of the prosthesis so as to improve the distribution of stress, promote bone growth, and enhance the biomechanical properties of the prosthesis. The mechanical characteristics of bone mineral density screw and traditional screw were compared by finite element analysis method, and redesigned by topology optimization. The direction of the newly proposed screw channel was the posterolateral entrance of the auricular surface, ending at the contralateral sacral cape. Compared to the original group, the maximum stress of the optimized prosthesis was decreased by 24.39%, the maximum stress of the sacrum in the optimized group was decreased by 27.23%, and the average strain energy density of the sacrum in the optimized group was increased by 8.43%. On the surface of screw and connecting plate, the area with micromotion more than 28 μm is reduced by 12.17%. On the screw surface, the area with micromotion more than 28 μm is reduced by 22.9%. The newly determined screw channel and optimized prosthesis design can effectively improve the biomechanical properties of a prosthesis and the microenvironment of osseointegration. This method can provide a reference for the fixation of prostheses in clinical pelvic reconstruction.
Collapse
|
7
|
Özcan M, Magini EB, Volpato GM, Cruz A, Volpato CAM. Additive Manufacturing Technologies for Fabrication of Biomaterials for Surgical Procedures in Dentistry: A Narrative Review. J Prosthodont 2022; 31:105-135. [PMID: 35313027 DOI: 10.1111/jopr.13484] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Accepted: 01/13/2022] [Indexed: 11/28/2022] Open
Abstract
PURPOSE To screen and critically appraise available literature regarding additive manufacturing technologies for bone graft material fabrication in dentistry. MATERIAL AND METHODS PubMed and Scopus were searched up to May 2021. Studies reporting the additive manufacturing techniques to manufacture scaffolds for intraoral bone defect reconstruction were considered eligible. A narrative review was synthesized to discuss the techniques for bone graft material fabrication in dentistry and the biomaterials used. RESULTS The databases search resulted in 933 articles. After removing duplicate articles (128 articles), the titles and abstracts of the remaining articles (805 articles) were evaluated. A total of 89 articles were included in this review. Reading these articles, 5 categories of additive manufacturing techniques were identified: material jetting, powder bed fusion, vat photopolymerization, binder jetting, and material extrusion. CONCLUSIONS Additive manufacturing technologies for bone graft material fabrication in dentistry, especially 3D bioprinting approaches, have been successfully used to fabricate bone graft material with distinct compositions.
Collapse
Affiliation(s)
- Mutlu Özcan
- Division of Dental Biomaterials, Center of Dental Medicine, Clinic for Reconstructive Dentistry, University of Zürich, Zürich, Switzerland
| | - Eduarda Blasi Magini
- Department of Dentistry, Federal University of Santa Catarina, Florianópolis, Brazil
| | | | - Ariadne Cruz
- Department of Dentistry, Federal University of Santa Catarina, Florianópolis, Brazil
| | | |
Collapse
|
8
|
Shape optimization of orthopedic porous scaffolds to enhance mechanical performance. J Mech Behav Biomed Mater 2022; 128:105098. [DOI: 10.1016/j.jmbbm.2022.105098] [Citation(s) in RCA: 4] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/23/2021] [Revised: 11/02/2021] [Accepted: 01/17/2022] [Indexed: 11/19/2022]
|
9
|
Tarassoli SP, Jessop ZM, Jovic T, Hawkins K, Whitaker IS. Candidate Bioinks for Extrusion 3D Bioprinting-A Systematic Review of the Literature. Front Bioeng Biotechnol 2021; 9:616753. [PMID: 34722473 PMCID: PMC8548422 DOI: 10.3389/fbioe.2021.616753] [Citation(s) in RCA: 22] [Impact Index Per Article: 7.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/13/2020] [Accepted: 04/19/2021] [Indexed: 11/25/2022] Open
Abstract
Purpose: Bioprinting is becoming an increasingly popular platform technology for engineering a variety of tissue types. Our aim was to identify biomaterials that have been found to be suitable for extrusion 3D bioprinting, outline their biomechanical properties and biocompatibility towards their application for bioprinting specific tissue types. This systematic review provides an in-depth overview of current biomaterials suitable for extrusion to aid bioink selection for specific research purposes and facilitate design of novel tailored bioinks. Methods: A systematic search was performed on EMBASE, PubMed, Scopus and Web of Science databases according to the PRISMA guidelines. References of relevant articles, between December 2006 to January 2018, on candidate bioinks used in extrusion 3D bioprinting were reviewed by two independent investigators against standardised inclusion and exclusion criteria. Data was extracted on bioprinter brand and model, printing technique and specifications (speed and resolution), bioink material and class of mechanical assessment, cell type, viability, and target tissue. Also noted were authors, study design (in vitro/in vivo), study duration and year of publication. Results: A total of 9,720 studies were identified, 123 of which met inclusion criteria, consisting of a total of 58 reports using natural biomaterials, 26 using synthetic biomaterials and 39 using a combination of biomaterials as bioinks. Alginate (n = 50) and PCL (n = 33) were the most commonly used bioinks, followed by gelatin (n = 18) and methacrylated gelatin (GelMA) (n = 16). Pneumatic extrusion bioprinting techniques were the most common (n = 78), followed by piston (n = 28). The majority of studies focus on the target tissue, most commonly bone and cartilage, and investigate only one bioink rather than assessing a range to identify those with the most promising printability and biocompatibility characteristics. The Bioscaffolder (GeSiM, Germany), 3D Discovery (regenHU, Switzerland), and Bioplotter (EnvisionTEC, Germany) were the most commonly used commercial bioprinters (n = 35 in total), but groups most often opted to create their own in-house devices (n = 20). Many studies also failed to specify whether the mechanical data reflected pre-, during or post-printing, pre- or post-crosslinking and with or without cells. Conclusions: Despite the continued increase in the variety of biocompatible synthetic materials available, there has been a shift change towards using natural rather than synthetic bioinks for extrusion bioprinting, dominated by alginate either alone or in combination with other biomaterials. On qualitative analysis, no link was demonstrated between the type of bioink or extrusion technique and the target tissue, indicating that bioprinting research is in its infancy with no established tissue specific bioinks or bioprinting techniques. Further research is needed on side-by-side characterisation of bioinks with standardisation of the type and timing of biomechanical assessment.
Collapse
Affiliation(s)
- Sam P Tarassoli
- Reconstructive Surgery & Regenerative Medicine Research Group (ReconRegen), Swansea University Medical School, Institute of Life Sciences, Swansea, United Kingdom
| | - Zita M Jessop
- Reconstructive Surgery & Regenerative Medicine Research Group (ReconRegen), Swansea University Medical School, Institute of Life Sciences, Swansea, United Kingdom.,The Welsh Centre for Burns & Plastic Surgery, Morriston Hospital, Swansea, United Kingdom
| | - Thomas Jovic
- Reconstructive Surgery & Regenerative Medicine Research Group (ReconRegen), Swansea University Medical School, Institute of Life Sciences, Swansea, United Kingdom.,The Welsh Centre for Burns & Plastic Surgery, Morriston Hospital, Swansea, United Kingdom
| | - Karl Hawkins
- Centre for NanoHealth, Swansea University Medical School, Institute of Life Sciences, Swansea, United Kingdom
| | - Iain S Whitaker
- Reconstructive Surgery & Regenerative Medicine Research Group (ReconRegen), Swansea University Medical School, Institute of Life Sciences, Swansea, United Kingdom.,The Welsh Centre for Burns & Plastic Surgery, Morriston Hospital, Swansea, United Kingdom
| |
Collapse
|
10
|
The advances of topology optimization techniques in orthopedic implants: A review. Med Biol Eng Comput 2021; 59:1673-1689. [PMID: 34363576 DOI: 10.1007/s11517-021-02361-7] [Citation(s) in RCA: 12] [Impact Index Per Article: 4.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/29/2020] [Accepted: 04/05/2021] [Indexed: 10/20/2022]
Abstract
Metal implants are widely used in the treatment of orthopedic diseases. However, owing to the mismatched elastic modulus of the bone and implants, stress shielding often occurs clinically which can result in failure of the implant or fractures around the implant. Topology optimization (TO) is a technique that can provide more efficient material distribution according to the objective function under the special load and boundary conditions. Several researchers have paid close attention to TO for optimal design of orthopedic implants. Thanks to the development of additive manufacturing (AM), the complex structure of the TO design can be fabricated. This article mainly focuses on the current stage of TO technique with respect to the global layout and hierarchical structure in orthopedic implants. In each aspect, diverse implants in different orthopedic fields related to TO design are discussed. The characteristics of implants, methods of TO, validation methods of the newly designed implants, and limitations of current research have been summarized. The review concludes with future challenges and directions for research. Wang TO design of global layout and local structure of implants in diverse fields of orthopedic.
Collapse
|
11
|
Catana D, Pop MA, Brus DI. Comparison between the Test and Simulation Results for PLA Structures 3D Printed, Bending Stressed. Molecules 2021; 26:molecules26113325. [PMID: 34205989 PMCID: PMC8198108 DOI: 10.3390/molecules26113325] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/13/2021] [Revised: 05/26/2021] [Accepted: 05/28/2021] [Indexed: 11/16/2022] Open
Abstract
The additive manufacturing process is one of the technical domains that has had a sustained development in recent decades. The designers' attention to equipment and materials for 3D printing has been focused on this type of process. The paper presents a comparison between the results of the bending tests and those of the simulation of the same type of stress applied on 3D-printed PLA and PLA-glass structures. The comparison of the results shows that they are close, and the simulation process can be applied with confidence for the streamline of filament consumption, with direct consequences on the volume and weight of additive manufactured structures. The paper determines whether the theories and concepts valid in the strength of materials can be applied to the additive manufacturing pieces. Thus, the study shows that the geometry of the cross-section, by its shape (circular or elliptical) and type (solid or ring shaped), influences the strength properties of 3D-printed structures. The use of simulation will allow a significant shortening of the design time of the new structures. Moreover, the simulation process was applied with good results on 3D-printed structures in which two types of filaments were used for a single piece (structure).
Collapse
Affiliation(s)
- Dorin Catana
- Department of Materials Engineering and Welding, Transilvania University of Brasov, 500036 Brasov, Romania
- Correspondence:
| | - Mihai-Alin Pop
- Department of Materials Science, Transilvania University of Brasov, 500036 Brasov, Romania;
| | - Denisa-Iulia Brus
- School for Doctoral Studies in Socio-Humanities, Dunarea de Jos University, 800008 Galati, Romania;
| |
Collapse
|
12
|
Lisiak-Myszke M, Marciniak D, Bieliński M, Sobczak H, Garbacewicz Ł, Drogoszewska B. Application of Finite Element Analysis in Oral and Maxillofacial Surgery-A Literature Review. MATERIALS 2020; 13:ma13143063. [PMID: 32659947 PMCID: PMC7411758 DOI: 10.3390/ma13143063] [Citation(s) in RCA: 36] [Impact Index Per Article: 9.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 05/30/2020] [Revised: 07/02/2020] [Accepted: 07/07/2020] [Indexed: 12/12/2022]
Abstract
In recent years in the field of biomechanics, the intensive development of various experimental methods has been observed. The implementation of virtual studies that for a long time have been successfully used in technical sciences also represents a new trend in dental engineering. Among these methods, finite element analysis (FEA) deserves special attention. FEA is a method used to analyze stresses and strains in complex mechanical systems. It enables the mathematical conversion and analysis of mechanical properties of a geometric object. Since the mechanical properties of the human skeleton cannot be examined in vivo, a discipline in which FEA has found particular application is oral and maxillofacial surgery. In this review we summarize the application of FEA in particular oral and maxillofacial fields such as traumatology, orthognathic surgery, reconstructive surgery and implantology presented in the current literature. Based on the available literature, we discuss the methodology and results of research where FEA has been used to understand the pathomechanism of fractures, identify optimal osteosynthesis methods, plan reconstructive operations and design intraosseous implants or osteosynthesis elements. As well as indicating the benefits of FEA in mechanical parameter analysis, we also point out the assumptions and simplifications that are commonly used. The understanding of FEA's opportunities and advantages as well as its limitations and main flaws is crucial to fully exploit its potential.
Collapse
Affiliation(s)
- Magdalena Lisiak-Myszke
- Maxillofacial Surgery Ward, Alfa-Med Medical Center, 85-095 Bydgoszcz, Poland
- Correspondence:
| | - Dawid Marciniak
- Faculty of Mechanical Engineering, Department of Manufacturing Technology, UTP University of Science and Technology, 85-796 Bydgoszcz, Poland; (D.M.); (M.B.)
| | - Marek Bieliński
- Faculty of Mechanical Engineering, Department of Manufacturing Technology, UTP University of Science and Technology, 85-796 Bydgoszcz, Poland; (D.M.); (M.B.)
| | - Hanna Sobczak
- Department of Maxillofacial Surgery, Medical University of Gdansk, 80-210 Gdansk, Poland; (H.S.); (Ł.G.); (B.D.)
| | - Łukasz Garbacewicz
- Department of Maxillofacial Surgery, Medical University of Gdansk, 80-210 Gdansk, Poland; (H.S.); (Ł.G.); (B.D.)
| | - Barbara Drogoszewska
- Department of Maxillofacial Surgery, Medical University of Gdansk, 80-210 Gdansk, Poland; (H.S.); (Ł.G.); (B.D.)
| |
Collapse
|
13
|
Haglund L, Ahangar P, Rosenzweig DH. Advancements in 3D printed scaffolds to mimic matrix complexities for musculoskeletal repair. CURRENT OPINION IN BIOMEDICAL ENGINEERING 2019. [DOI: 10.1016/j.cobme.2019.06.002] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/18/2022]
|