Abstract
PURPOSE
The FNA-CT is useful for the diagnosis of MTC. The aim of this study was to evaluate the performance of FNA-CT in TNs coexisting with CCH.
METHODS
This study retrospectively reviewed the records of 11 patients with TNs submitted to thyroidectomy on the basis of elevated basal and/or stimulated serum CT values, which at histology were not confirmed to be MTC. The results obtained in this group were compared with those of a previously reported group of histologically proven MTC patients submitted to an identical presurgical evaluation. All patients, negative for known mutations in the RET proto-oncogene, were preoperatively submitted to neck ultrasound, FNA-cytology, and FNA-CT.
RESULTS
Approximately 6 of 11 patients showed increased (>36 ng/mL, as established in previous studies not involving patients with CCH) FNA-CT. All these patients showed diffuse CCH at histology in the thyroid lobe submitted to FNA; 5 of them were benign at histology, while only one was malignant (papillary thyroid carcinoma, PTC). The remaining 5 of 11 patients had low FNA-CT (<36 ng/mL), and all of them showed only focal CCH in the lobe submitted to FNA; three of them were malignant (2 PTC, 1 follicular carcinoma), while two were benign.
CONCLUSIONS
Employing the currently proposed cut-off values, false-positive FNA-CT results may be observed in benign/malignant TNs with coexisting diffuse CCH. FNA-CT must therefore be cautiously used in the diagnostic approach for patients with TNs and a slightly increased basal or stimulated serum CT concentration in order to avoid unnecessary surgery.