1
|
Ho GWK, Thaarun T, Ee NJ, Boon TC, Ning KZ, Cove ME, Loh WNH. A systematic review on the use of sevoflurane in the management of status asthmaticus in adults. Crit Care 2024; 28:334. [PMID: 39402635 PMCID: PMC11476279 DOI: 10.1186/s13054-024-05122-8] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/11/2024] [Accepted: 10/05/2024] [Indexed: 10/19/2024] Open
Abstract
BACKGROUND To conduct a systematic review looking into the use of sevoflurane in the management of status asthmaticus (SA) in adults. METHODS We performed a systematic search on PubMed, EMBASE, and The Cochrane Library - CENTRAL through 23rd August 2023, restricting to studies reported in English. We included studies reporting use of sevoflurane in asthmatics beyond its use as an anaesthetic agent in surgeries i.e. in the emergency department (ED) and critical care setting, and focused on patient's clinical parameters, ventilation pressures and weaning of invasive ventilation. RESULTS A total of 13 publications fulfilled the inclusion criteria, comprising of 18 cases. All publications were of case reports/ series and conference abstracts, and no randomised trials were available. Most patients required intubation despite best medical management before sevoflurane administration, and high airway pressures and respiratory acidosis were apparent. There was significant heterogeneity regarding severity of asthma, treatment instituted, and the delivery, duration and concentration of sevoflurane administered. Many of the studies also did not quantify the changes in parameters pre- and post-sevoflurane. Sixteen patients experienced improvements in clinical status with sevoflurane administration-one required escalation to extracorporeal membrane oxygenation (ECMO), and another did not survive. CONCLUSION The systematic review suggests sevoflurane can be a valuable treatment option in SA. As these cases are rare and heterogenous, further prospective case series are needed to support this.
Collapse
Affiliation(s)
- Gerald Wai Kit Ho
- Department of Anaesthesia, National University Hospital, 5 Lower Kent Ridge Rd, Singapore, 119074, Singapore.
| | | | - Neo Jean Ee
- Yong Loo Lin School of Medicine, National University of Singapore, Singapore, Singapore
| | - Teo Chong Boon
- Department of Medicine, National University Hospital, Singapore, Singapore
| | - Koh Zheng Ning
- Department of Anaesthesia, National University Hospital, 5 Lower Kent Ridge Rd, Singapore, 119074, Singapore
| | - Matthew Edward Cove
- Division of Respiratory and Critical Care Medicine, Department of Medicine, National University Hospital, Singapore, Singapore
| | - Will Ne-Hooi Loh
- Department of Anaesthesia, National University Hospital, 5 Lower Kent Ridge Rd, Singapore, 119074, Singapore
- Department of Anaesthesia, Yong Loo Lin School of Medicine, National University of Singapore, Singapore, Singapore
| |
Collapse
|
2
|
Müller-Wirtz LM, O'Gara B, Gama de Abreu M, Schultz MJ, Beitler JR, Jerath A, Meiser A. Volatile anesthetics for lung- and diaphragm-protective sedation. Crit Care 2024; 28:269. [PMID: 39217380 PMCID: PMC11366159 DOI: 10.1186/s13054-024-05049-0] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/12/2024] [Accepted: 07/30/2024] [Indexed: 09/04/2024] Open
Abstract
This review explores the complex interactions between sedation and invasive ventilation and examines the potential of volatile anesthetics for lung- and diaphragm-protective sedation. In the early stages of invasive ventilation, many critically ill patients experience insufficient respiratory drive and effort, leading to compromised diaphragm function. Compared with common intravenous agents, inhaled sedation with volatile anesthetics better preserves respiratory drive, potentially helping to maintain diaphragm function during prolonged periods of invasive ventilation. In turn, higher concentrations of volatile anesthetics reduce the size of spontaneously generated tidal volumes, potentially reducing lung stress and strain and with that the risk of self-inflicted lung injury. Taken together, inhaled sedation may allow titration of respiratory drive to maintain inspiratory efforts within lung- and diaphragm-protective ranges. Particularly in patients who are expected to require prolonged invasive ventilation, in whom the restoration of adequate but safe inspiratory effort is crucial for successful weaning, inhaled sedation represents an attractive option for lung- and diaphragm-protective sedation. A technical limitation is ventilatory dead space introduced by volatile anesthetic reflectors, although this impact is minimal and comparable to ventilation with heat and moisture exchangers. Further studies are imperative for a comprehensive understanding of the specific effects of inhaled sedation on respiratory drive and effort and, ultimately, how this translates into patient-centered outcomes in critically ill patients.
Collapse
Affiliation(s)
- Lukas M Müller-Wirtz
- Department of Anesthesiology, Outcomes Research Consortium, Cleveland Clinic, Cleveland, OH, USA
- Department of Anesthesiology, Intensive Care and Pain Therapy, Faculty of Medicine, Saarland University Medical Center and Saarland University, Homburg, Saarland, Germany
- Department of Anesthesiology, Friedrich-Alexander-Universität Erlangen-Nürnberg, University Hospital Erlangen, Erlangen, Germany
| | - Brian O'Gara
- Department of Anesthesia, Critical Care, and Pain Medicine, Beth Israel Deaconess Medical Center, Boston, MA, USA
| | - Marcelo Gama de Abreu
- Department of Anesthesiology, Outcomes Research Consortium, Cleveland Clinic, Cleveland, OH, USA
- Division of Intensive Care and Resuscitation, Department of Anesthesiology, Cleveland Clinic, Cleveland, OH, USA
- Division of Cardiothoracic Anesthesiology, Department of Anesthesiology, Cleveland Clinic, Cleveland, OH, USA
| | - Marcus J Schultz
- Department of Intensive Care, Amsterdam University Medical Center, Amsterdam, The Netherlands
- Department of Anesthesiology, Intensive Care Medicine and Pain Medicine, Division of Cardiac Thoracic Vascular Anesthesia and Intensive Care Medicine, Medical University of Vienna, Vienna, Austria
| | - Jeremy R Beitler
- Columbia Respiratory Critical Care Trials Group, New York-Presbyterian Hospital and Columbia University, New York, NY, USA
| | - Angela Jerath
- Department of Anesthesiology and Pain Medicine, Temerty Faculty of Medicine, University of Toronto, Toronto, ON, Canada
- Department of Anesthesia, Sunnybrook Health Sciences Centre, Toronto, ON, Canada
| | - Andreas Meiser
- Department of Anesthesiology, Intensive Care and Pain Therapy, Faculty of Medicine, Saarland University Medical Center and Saarland University, Homburg, Saarland, Germany.
| |
Collapse
|
3
|
O'Gara B, Boncyk C, Meiser A, Jerath A, Bellgardt M, Jabaudon M, Beitler JR, Hughes CG. Volatile Anesthetic Sedation for Critically Ill Patients. Anesthesiology 2024; 141:163-174. [PMID: 38860793 DOI: 10.1097/aln.0000000000004994] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 06/12/2024]
Abstract
Volatile anesthetics have multiple properties that make them useful for sedation in the intensive care unit. The team-based approach to volatile anesthetic sedation leverages these properties to provide a safe and effective alternative to intravenous sedatives.
Collapse
Affiliation(s)
- Brian O'Gara
- Beth Israel Deaconess Medical Center, Department of Anaesthesia, Critical Care, and Pain Medicine, Harvard Medical School, Boston, Massachusetts
| | - Christina Boncyk
- Vanderbilt University Medical Center, Department of Anesthesiology, Vanderbilt University School of Medicine, Nashville, Tennessee
| | - Andreas Meiser
- Saarland University Hospital, Privatdozent Medical Faculty of Saarland University, Homburg, Germany
| | - Angela Jerath
- Sunnybrook Research Institute, Department of Anesthesia, Sunnybrook Health Sciences Centre, Toronto, Canada; Department of Anesthesiology and Pain Medicine, Temerty Faculty of Medicine, University of Toronto, Toronto, Canada
| | - Martin Bellgardt
- St. Josef-Hospital, University Hospital of Ruhr-University of Bochum, Bochum, Germany
| | - Matthieu Jabaudon
- University Hospital Center Clermont-Ferrand, Department of Perioperative Medicine, Clermont Auvergne University, Institute of Genetics, Reproduction, and Development, National Center for Scientific Research, National Institute of Health and Medical Research, Clermont-Ferrand, France
| | - Jeremy R Beitler
- New York Presbyterian/Columbia University Medical Center, Vagelos College of Physicians and Surgeons, Columbia University, New York, New York
| | - Christopher G Hughes
- Vanderbilt University Medical Center, Department of Anesthesiology, Vanderbilt University School of Medicine, Nashville, Tennessee
| |
Collapse
|
4
|
Müller-Wirtz LM, Becher T, Günther U, Bellgardt M, Sackey P, Volk T, Meiser A. Ventilatory Effects of Isoflurane Sedation via the Sedaconda ACD-S versus ACD-L: A Substudy of a Randomized Trial. J Clin Med 2023; 12:jcm12093314. [PMID: 37176754 PMCID: PMC10179426 DOI: 10.3390/jcm12093314] [Citation(s) in RCA: 1] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/13/2023] [Revised: 04/27/2023] [Accepted: 05/04/2023] [Indexed: 05/15/2023] Open
Abstract
Devices used to deliver inhaled sedation increase dead space ventilation. We therefore compared ventilatory effects among isoflurane sedation via the Sedaconda ACD-S (internal volume: 50 mL), isoflurane sedation via the Sedaconda ACD-L (100 mL), and propofol sedation with standard mechanical ventilation with heat and moisture exchangers (HME). This is a substudy of a randomized trial that compared inhaled isoflurane sedation via the ACD-S or ACD-L to intravenous propofol sedation in 301 intensive care patients. Data from the first 24 h after study inclusion were analyzed using linear mixed models. Primary outcome was minute ventilation. Secondary outcomes were tidal volume, respiratory rate, arterial carbon dioxide pressure, and isoflurane consumption. In total, 151 patients were randomized to propofol and 150 to isoflurane sedation; 64 patients received isoflurane via the ACD-S and 86 patients via the ACD-L. While use of the ACD-L was associated with higher minute ventilation (average difference (95% confidence interval): 1.3 (0.7, 1.8) L/min, p < 0.001), higher tidal volumes (44 (16, 72) mL, p = 0.002), higher respiratory rates (1.2 (0.1, 2.2) breaths/min, p = 0.025), and higher arterial carbon dioxide pressures (3.4 (1.2, 5.6) mmHg, p = 0.002), use of the ACD-S did not significantly affect ventilation compared to standard mechanical ventilation and sedation. Isoflurane consumption was slightly less with the ACD-L compared to the ACD-S (-0.7 (-1.3, 0.1) mL/h, p = 0.022). The Sedaconda ACD-S compared to the ACD-L is associated with reduced minute ventilation and does not significantly affect ventilation compared to a standard mechanical ventilation and sedation setting. The smaller ACD-S is therefore the device of choice to minimize impact on ventilation, especially in patients with a limited ability to compensate (e.g., COPD patients). Volatile anesthetic consumption is slightly higher with the ACD-S compared to the ACD-L.
Collapse
Affiliation(s)
- Lukas M Müller-Wirtz
- Department of Anaesthesiology, Intensive Care and Pain Therapy, Saarland University Medical Center and Saarland University Faculty of Medicine, 66421 Homburg, Germany
- Outcomes Research Consortium, Cleveland, OH 44195, USA
| | - Tobias Becher
- Department of Anesthesiology and Intensive Care Medicine, Campus Kiel, University Medical Center Schleswig-Holstein, 24118 Kiel, Germany
| | - Ulf Günther
- Department of Anaesthesiology, Intensive Care, Emergency Medicine, Pain Therapy, University Hospital Oldenburg, 26133 Oldenburg, Germany
| | - Martin Bellgardt
- Department of Anaesthesiology and Intensive Care Medicine, St. Josef-Hospital, University Hospital of the Ruhr-University Bochum, 44780 Bochum, Germany
| | - Peter Sackey
- Unit of Anesthesiology and Intensive Care, Department of Physiology and Pharmacology, Karolinska Institute, 17177 Stockholm, Sweden
- Sedana Medical AB, 18232 Danderyd, Sweden
| | - Thomas Volk
- Department of Anaesthesiology, Intensive Care and Pain Therapy, Saarland University Medical Center and Saarland University Faculty of Medicine, 66421 Homburg, Germany
- Outcomes Research Consortium, Cleveland, OH 44195, USA
| | - Andreas Meiser
- Department of Anaesthesiology, Intensive Care and Pain Therapy, Saarland University Medical Center and Saarland University Faculty of Medicine, 66421 Homburg, Germany
| |
Collapse
|
5
|
Müller-Wirtz LM, Grimm D, Albrecht FW, Fink T, Volk T, Meiser A. Increased Respiratory Drive after Prolonged Isoflurane Sedation: A Retrospective Cohort Study. J Clin Med 2022; 11:jcm11185422. [PMID: 36143068 PMCID: PMC9504554 DOI: 10.3390/jcm11185422] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/29/2022] [Revised: 09/11/2022] [Accepted: 09/12/2022] [Indexed: 11/16/2022] Open
Abstract
Low-dose isoflurane stimulates spontaneous breathing. We, therefore, tested the hypothesis that isoflurane compared to propofol sedation for at least 48 h is associated with increased respiratory drive in intensive care patients after sedation stop. All patients in our intensive care unit receiving at least 48 h of isoflurane or propofol sedation in 2019 were included. The primary outcome was increased respiratory drive over 72 h after sedation stop, defined as an arterial carbon dioxide pressure below 35 mmHg and a base excess more than −2 mmol/L. Secondary outcomes were acid–base balance and ventilatory parameters. We analyzed 64 patients, 23 patients sedated with isoflurane and 41 patients sedated with propofol. Patients sedated with isoflurane were about three times as likely to show increased respiratory drive after sedation stop than those sedated with propofol: adjusted risk ratio [95% confidence interval]: 2.9 [1.3, 6.5], p = 0.010. After sedation stop, tidal volumes were significantly greater and arterial carbon dioxide partial pressures were significantly lower, while respiratory rates did not differ in isoflurane versus propofol-sedated patients. In conclusion, prolonged isoflurane use in intensive care patients is associated with increased respiratory drive after sedation stop. Beneficial effects of isoflurane sedation on respiratory drive may, thus, extend beyond the actual period of sedation.
Collapse
Affiliation(s)
- Lukas Martin Müller-Wirtz
- Department of Anaesthesiology, Intensive Care and Pain Therapy, Saarland University Medical Center and Saarland University Faculty of Medicine, 66424 Homburg, Germany
- Outcomes Research Consortium, Cleveland, OH 44195, USA
- Correspondence: (L.M.M.-W.); (A.M.)
| | - Dustin Grimm
- Department of Anaesthesiology, Intensive Care and Pain Therapy, Saarland University Medical Center and Saarland University Faculty of Medicine, 66424 Homburg, Germany
| | - Frederic Walter Albrecht
- Department of Anaesthesiology, Intensive Care and Pain Therapy, Saarland University Medical Center and Saarland University Faculty of Medicine, 66424 Homburg, Germany
| | - Tobias Fink
- Department of Anaesthesiology, Intensive Care and Pain Therapy, Saarland University Medical Center and Saarland University Faculty of Medicine, 66424 Homburg, Germany
- Outcomes Research Consortium, Cleveland, OH 44195, USA
| | - Thomas Volk
- Department of Anaesthesiology, Intensive Care and Pain Therapy, Saarland University Medical Center and Saarland University Faculty of Medicine, 66424 Homburg, Germany
- Outcomes Research Consortium, Cleveland, OH 44195, USA
| | - Andreas Meiser
- Department of Anaesthesiology, Intensive Care and Pain Therapy, Saarland University Medical Center and Saarland University Faculty of Medicine, 66424 Homburg, Germany
- Correspondence: (L.M.M.-W.); (A.M.)
| |
Collapse
|
6
|
Kundra P, Goswami S, Parameswari A. Advances in vaporisation: A narrative review. Indian J Anaesth 2020; 64:171-180. [PMID: 32346162 PMCID: PMC7179779 DOI: 10.4103/ija.ija_850_19] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/19/2019] [Revised: 01/08/2020] [Accepted: 01/24/2020] [Indexed: 11/30/2022] Open
Abstract
The output of inhalational agents from modern vaporisers are both electronically and pneumatically controlled. They are designed to deliver set agent concentrations accurately with low fresh gas flows and possess enhanced safety features. The purpose of this review article is to give an overview of three modern vaporisers, namely, the Aladin cassette vaporiser, injection vaporisers and AnaConDa™. The Aladin cassette is integrated with Datex Ohmeda S/5 ADU and GE Aisys anaesthesia machines. The electronic vapour control unit is incorporated within the anaesthesia machine. The agent specific cassettes act as a detachable vaporising chamber. The system can work as a variable bypass and measured flow vaporiser but requires a power supply to function. Injection vaporisers can achieve the set end-tidal agent concentration very rapidly with even metabolic flow rates. Hence, anaesthetic depth can be rapidly altered with minimal wastage and theatre pollution. The two types of injection vaporisers, namely, Maquet and DIVA™ are customised to function with Maquet FLOW-i and the Drager Zeus anaesthesia machine, respectively. AnaConDa™ is a combination of vaporiser and humidity and moisture exchange filter which can be fitted in the ventilatory circuit. It is primarily designed for use in intensive care for sedation and out of operating room use.
Collapse
Affiliation(s)
- Pankaj Kundra
- Department of Anaesthesiology and Critical Care, Jawaharlal Institute of Postgraduate Medical Education and Research, Puducherry, Tamil Nadu, India
| | - Shreya Goswami
- Department of Anaesthesiology, Washington University School of Medicine, St Louis, MO, USA
| | - Aruna Parameswari
- Department of Anaesthesiology, Critical Care and Pain Medicine, Sri Ramachandra University, Chennai, Tamil Nadu, India
| |
Collapse
|
7
|
Bomberg H, Meiser F, Daume P, Bellgardt M, Volk T, Sessler DI, Groesdonk HV, Meiser A. Halving the Volume of AnaConDa: Evaluation of a New Small-Volume Anesthetic Reflector in a Test Lung Model. Anesth Analg 2020; 129:371-379. [PMID: 29787413 DOI: 10.1213/ane.0000000000003452] [Citation(s) in RCA: 15] [Impact Index Per Article: 3.8] [Reference Citation Analysis] [Abstract] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/28/2023]
Abstract
BACKGROUND Volatile anesthetics are increasingly used for sedation in intensive care units. The most common administration system is AnaConDa-100 mL (ACD-100; Sedana Medical, Uppsala, Sweden), which reflects volatile anesthetics in open ventilation circuits. AnaConDa-50 mL (ACD-50) is a new device with half the volumetric dead space. Carbon dioxide (CO2) can be retained with both devices. We therefore compared the CO2 elimination and isoflurane reflection efficiency of both devices. METHODS A test lung constantly insufflated with CO2 was ventilated with a tidal volume of 500 mL at 10 breaths/min. End-tidal CO2 (EtCO2) partial pressure was measured using 3 different devices: a heat-and-moisture exchanger (HME, 35 mL), ACD-100, and ACD-50 under 4 different experimental conditions: ambient temperature pressure (ATP), body temperature pressure saturated (BTPS) conditions, BTPS with 0.4 Vol% isoflurane (ISO-0.4), and BTPS with 1.2 Vol% isoflurane. Fifty breaths were recorded at 3 time points (n = 150) for each device and each condition. To determine device dead space, we adjusted the tidal volume to maintain normocapnia (n = 3), for each device. Thereafter, we determined reflection efficiency by measuring isoflurane concentrations at infusion rates varying from 0.5 to 20 mL/h (n = 3), for each device. RESULTS EtCO2 was consistently greater with ACD-100 than with ACD-50 and HME (ISO-0.4, mean ± standard deviations: ACD-100, 52.4 ± 0.8; ACD-50, 44.4 ± 0.8; HME, 40.1 ± 0.4 mm Hg; differences of means of EtCO2 [respective 95% confidence intervals]: ACD-100 - ACD-50, 8.0 [7.9-8.1] mm Hg, P < .001; ACD-100 - HME, 12.3 [12.2-12.4] mm Hg, P < .001; ACD-50 - HME, 4.3 [4.2-4.3] mm Hg, P < .001). It was greatest under ATP, less under BTPS, and least with ISO-0.4 and BTPS with 1.2 Vol% isoflurane. In addition to the 100 or 50 mL "volumetric dead space" of each AnaConDa, "reflective dead space" was 40 mL with ACD-100 and 25 mL with ACD-50 when using isoflurane. Isoflurane reflection was highest under ATP. Under BTPS with CO2 insufflation and isoflurane concentrations around 0.4 Vol%, reflection efficiency was 93% with ACD-100 and 80% with ACD-50. CONCLUSIONS Isoflurane reflection remained sufficient with the ACD-50 at clinical anesthetic concentrations, while CO2 elimination was improved. The ACD-50 should be practical for tidal volumes as low as 200 mL, allowing lung-protective ventilation even in small patients.
Collapse
Affiliation(s)
- Hagen Bomberg
- From the Department of Anesthesiology, Intensive Care Medicine and Pain Medicine, Saarland University Medical Centre, University of Saarland, Homburg/Saar, Germany
| | - Franziska Meiser
- From the Department of Anesthesiology, Intensive Care Medicine and Pain Medicine, Saarland University Medical Centre, University of Saarland, Homburg/Saar, Germany
| | - Philipp Daume
- From the Department of Anesthesiology, Intensive Care Medicine and Pain Medicine, Saarland University Medical Centre, University of Saarland, Homburg/Saar, Germany
| | - Martin Bellgardt
- Department of Anesthesiology and Intensive Care Medicine, St Josef Hospital, Katholisches Klinikum Bochum, University Hospital, Ruhr-University of Bochum, Bochum, Germany
| | - Thomas Volk
- From the Department of Anesthesiology, Intensive Care Medicine and Pain Medicine, Saarland University Medical Centre, University of Saarland, Homburg/Saar, Germany
| | - Daniel I Sessler
- Department of Outcomes Research, Anesthesiology Institute, Cleveland Clinic, Cleveland, Ohio
| | - Heinrich V Groesdonk
- From the Department of Anesthesiology, Intensive Care Medicine and Pain Medicine, Saarland University Medical Centre, University of Saarland, Homburg/Saar, Germany
| | - Andreas Meiser
- From the Department of Anesthesiology, Intensive Care Medicine and Pain Medicine, Saarland University Medical Centre, University of Saarland, Homburg/Saar, Germany
| |
Collapse
|
8
|
Comparison of the use of AnaConDa® versus AnaConDa-S® during the post-operative period of cardiac surgery under standard conditions of practice. J Clin Monit Comput 2019; 34:89-95. [PMID: 30784010 PMCID: PMC7222112 DOI: 10.1007/s10877-019-00285-0] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Key Words] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/25/2018] [Accepted: 02/13/2019] [Indexed: 01/16/2023]
Abstract
Changes have been made to the AnaConDa device (Sedana Medical, Stockholm, Sweden), decreasing its size to reduce dead space and carbon dioxide (CO2) retention. However, this also involves a decrease in the surface area of the activated carbon filter. The CO2 elimination and sevoflurane (SEV) reflection of the old device (ACD-100) were thus compared with the new version (ACD-50) in patients sedated after coronary artery bypass graft surgery. After ERC approval and written informed consent, 23 patients were sedated with SEV, using first the ACD-100 and then the ACD-50 for 60 min each. With each device, patients were ventilated with tidal volumes (TV) of 5 ml/kg of ideal body weight for the first 30 min, and with 7 ml/kg for the next 30 min. Ventilation parameters, arterial blood gases, Bispectral-Index™ (BIS, Aspect Medical Systems Inc., Newton, MA, USA), SEV concentrations exhaled by the patient (SEV-exhaled) and from the expiratory hose (SEV-lost) were recorded every 30 min. A SEV reflection index was calculated: SRI [%] = 100 × (1 − (SEV-lost/SEV-exhaled)). Data were compared using ANOVA with repeated measurements and Student’s T-tests for pairs. Respiratory rates, tidal and minute volumes were not significantly different between the two devices. End tidal and arterial CO2 partial pressures were significantly higher with the ACD-100 as compared with the ACD-50. SEV infusion rate remained constant. SEV reflection was higher (SRI: ACD-100 vs. ACD-50, TV 5 ml/kg: 95.29 ± 6.45 vs. 85.54 ± 11.15, p = 0.001; 7 ml/kg: 93.42 ± 6.55 vs. 88.77 ± 12.26, p = 0.003). BIS was significantly lower when using the higher TV (60.91 ± 9.99 vs. 66.57 ± 8.22, p = 0.012), although this difference was not clinically relevant. During postoperative sedation, the use of ACD-50 significantly reduced CO2 retention. SEV reflection was slightly reduced. However, patients remained sufficiently sedated without increasing SEV infusion.
Collapse
|
9
|
Halving the volume of AnaConDa: initial clinical experience with a new small-volume anaesthetic reflector in critically ill patients-a quality improvement project. J Clin Monit Comput 2018; 32:639-646. [PMID: 29700664 DOI: 10.1007/s10877-018-0146-z] [Citation(s) in RCA: 12] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/10/2017] [Accepted: 04/23/2018] [Indexed: 02/07/2023]
Abstract
AnaConDa-100 ml (ACD-100, Sedana Medical, Uppsala, Sweden) is well established for inhalation sedation in the intensive care unit. But because of its large dead space, the system can retain carbon dioxide (CO2) and increase ventilatory demands. We therefore evaluated whether AnaConDa-50 ml (ACD-50), a device with half the internal volume, reduces CO2 retention and ventilatory demands during sedation of invasively ventilated, critically ill patients. Ten patients participated in this cross-over protocol. After sedation with isoflurane via ACD-100 for 24 h, the 5-h observation period started. During the first hour, ACD-100 was used; for the next 2 h, ACD-50; and for the last 2 h, ACD-100 was used again. Sedation was titrated to Richmond Agitation and Sedation Scale (RASS) score - 3 to - 4 and a processed electroencephalogram (Narcotrend Index, Narcotrend-Gruppe, Hannover, Germany) was recorded. Minute ventilation, CO2 elimination, and isoflurane consumption were compared. All patients were deeply sedated (Narcotrend Index, mean ± SD: 38 ± 10; RASS scores - 3 to - 5) and breathed spontaneously with pressure support throughout the observation period. Infusion rates of isoflurane and opioid, either remifentanil or sufentanil, as well as ventilator settings were unchanged. Minute ventilation and end-tidal CO2 were significantly reduced with the ACD-50, respiratory rate remained unchanged, and tidal volume decreased by 66 ± 43 ml. End-tidal isoflurane concentrations were also slightly reduced while haemodynamic measures remained constant. The ACD-50 reduces the tidal volume needed to eliminate carbon dioxide without augmenting isoflurane consumption.
Collapse
|
10
|
Mashari A, Fedorko L, Fisher JA, Klein M, Wąsowicz M, Meineri M. High volatile anaesthetic conservation with a digital in-line vaporizer and a reflector. Acta Anaesthesiol Scand 2018; 62:177-185. [PMID: 29068042 DOI: 10.1111/aas.13017] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/06/2017] [Revised: 06/29/2017] [Accepted: 09/29/2017] [Indexed: 12/01/2022]
Abstract
BACKGROUND A volatile anaesthetic (VA) reflector can reduce VA consumption (VAC) at the cost of fine control of its delivery and CO2 accumulation. A digital in-line vaporizer and a second CO2 absorber circumvent both of these limitations. We hypothesized that the combination of a VA reflector with an in-line vaporizer would yield substantial VA conservation, independent of fresh gas flow (FGF) in a circle circuit, and provide fine control of inspired VA concentrations. METHOD Prospective observational study on six Yorkshire pigs. A secondary anaesthetic circuit consisting of a Y-piece with 2 one-way valves, an in-line vaporizer and a CO2 absorber in the inspiratory limb was connected to the patient's side of the VA reflector. The other side was connected to the Y-piece of a circle anaesthetic circuit. In six pigs, an inspired concentration of sevoflurane of 2.5% was maintained by the in-line vaporizer. We measured VAC at FGF of 1, 4 and 10 l/min. RESULTS With the secondary circuit, VAC was 55% less than with the circle system alone at FGF 1 l/min, and independent of FGF over the range of 1-10 l/min. Insertion of a CO2 absorber in the secondary circuit reduced Pet CO2 by 1.3-2.0 kpa (10-15 mmHg). CONCLUSION A secondary circuit with reflector and in-line vaporizer provides highly efficient anaesthetic delivery, independent of FGF. A second CO2 absorber was necessary to scavenge the CO2 reflected by the anaesthetic reflector. This secondary circuit may turn any open circuit ventilator into an anaesthetic delivery unit.
Collapse
Affiliation(s)
- A. Mashari
- Department of Anesthesia and Pain Management; Toronto General Hospital; University Health Network; University of Toronto; Toronto Canada
| | - L. Fedorko
- Department of Anesthesia and Pain Management; Toronto General Hospital; University Health Network; University of Toronto; Toronto Canada
- Thornhill Research Inc.; Toronto Canada
| | - J. A. Fisher
- Department of Anesthesia and Pain Management; Toronto General Hospital; University Health Network; University of Toronto; Toronto Canada
- Thornhill Research Inc.; Toronto Canada
| | - M. Klein
- Department of Engineering; Thornhill Research Inc.; Toronto Canada
| | - M. Wąsowicz
- Department of Anesthesia and Pain Management; Toronto General Hospital; University Health Network; University of Toronto; Toronto Canada
| | - M. Meineri
- Department of Anesthesia and Pain Management; Toronto General Hospital; University Health Network; University of Toronto; Toronto Canada
| |
Collapse
|
11
|
Farrell R, Oomen G, Carey P. A technical review of the history, development and performance of the anaesthetic conserving device "AnaConDa" for delivering volatile anaesthetic in intensive and post-operative critical care. J Clin Monit Comput 2018; 32:595-604. [PMID: 29388094 PMCID: PMC6061082 DOI: 10.1007/s10877-017-0097-9] [Citation(s) in RCA: 35] [Impact Index Per Article: 5.8] [Reference Citation Analysis] [Abstract] [Key Words] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/21/2017] [Accepted: 12/21/2017] [Indexed: 12/11/2022]
Abstract
There is a shift in critical care to adopt volatile anaesthetics as sedatives for certain patients using mechanical ventilation. Accompanying this shift is a growing body of literature describing the advantages or disadvantages of using isoflurane or sevoflurane for long term sedation. This practise requires a cost effective, efficient and safe means to deliver these drugs that can simultaneously operate with modern critical care ventilators and ventilation protocols while protecting the care environment and care workers from excessive exposure to the drugs. The anaesthetic conserving device (“AnaConDa”, Sedana Medical) is one device that delivers a safe sedative dose of either isoflurane or sevoflurane to a patient using existing critical care ventilators, common syringe pumps and gas monitors. The device is essentially a small disposable anaesthetic vaporizer and HME filter combined into one airway component. Similar to an HME filter, the device reflects moisture back to the patient, but also reflects 90% of the anaesthetic by adsorbing and releasing the drug using a proprietary carbon filament reflecting medium. This reflection reduces the total amount of anaesthetic needed, reducing that which is exhausted or scavenged upon exhalation. It can be used for 24 h of sedation, and fits into current critical care ventilator circuits almost without modifications. This article will describe the physical characteristics of the device, how it works, its development history and the performance parameters under which it can be used.
Collapse
Affiliation(s)
- Ron Farrell
- Sedana Medical, The Village Center, Two Mile House, Naas, Co. Kildare, Ireland.
| | - Glen Oomen
- Sedana Medical, Unit 306, 397 King Street West, Dundas, ON, L9H 1W9, Canada
| | - Pauric Carey
- Sedana Medical, The Village Center, Two Mile House, Naas, Co. Kildare, Ireland
| |
Collapse
|
12
|
Volumetric and reflective device dead space of anaesthetic reflectors under different conditions. J Clin Monit Comput 2018; 32:1073-1080. [PMID: 29374847 DOI: 10.1007/s10877-018-0105-8] [Citation(s) in RCA: 12] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/17/2016] [Accepted: 01/20/2018] [Indexed: 01/15/2023]
Abstract
Inhalation sedation is increasingly performed in intensive care units. For this purpose, two anaesthetic reflectors, AnaConDa™ and Mirus™ are commercially available. However, their internal volume (100 ml) and possible carbon dioxide reflection raised concerns. Therefore, we compared carbon dioxide elimination of both with a heat moisture exchanger (HME, 35 ml) in a test lung model. A constant flow of carbon dioxide was insufflated into the test lung, ventilated with 500 ml, 10 breaths per minute. HME, MIRUS and AnaConDa were connected successively. Inspired (insp-CO2) and end-tidal carbon dioxide concentrations (et-CO2) were measured under four conditions: ambient temperature pressure (ATP), body temperature pressure saturated (BTPS), BTPS with 0.4 Vol% (ISO-0.4), and 1.2 Vol% isoflurane (ISO-1.2). Tidal volume increase to maintain normocapnia was also determined. Insp-CO2 was higher with AnaConDa compared to MIRUS and higher under ATP compared to BTPS. Isoflurane further decreased insp-CO2 and abolished the difference between AnaConDa and MIRUS. Et-CO2 showed similar effects. In addition to volumetric dead space, reflective dead space was determined as 198 ± 6/58 ± 6/35 ± 0/25 ± 0 ml under ATP/BTPS/ISO-0.4/ISO-1.2 conditions for AnaConDa, and 92 ± 6/25 ± 0/25 ± 0/25 ± 0 ml under the same conditions for MIRUS, respectively. Under BTPS conditions and with the use of moderate inhaled agent concentrations, reflective dead space is small and similar between the two devices.
Collapse
|
13
|
Meiser A, Bomberg H, Volk T, Groesdonk HV. [New technical developments for inhaled sedation]. Anaesthesist 2017; 66:274-282. [PMID: 28144686 DOI: 10.1007/s00101-017-0269-5] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/07/2023]
Abstract
The circle system has been in use for more than 100 years, whereas the first clinical application of an anaesthetic reflector was reported just 15 years ago. In the circle system, all breathing gas is rebreathed after carbon dioxide absorption. A reflector, on the other hand, with the breathing gas flowing to and fro, specifically retains the anaesthetic during expiration and resupplies it during the next inspiration. A high reflection efficiency (number of molecules resupplied/number of molecules exhaled, RE 80-90%) decreases consumption. In analogy to the fresh gas flow of a circle system, pulmonary clearance ((1-RE) × minute ventilation) defines the opposition between consumption and control of the concentration.It was not until reflection systems became available that volatile anaesthetics were used routinely in some intensive care units. Their advantages, such as easy handling, and better ventilatory capabilities of intensive care versus anaesthesia ventilators, were basic preconditions for this. Apart from AnaConDa™ (Sedana Medical, Uppsala, Sweden), the new MIRUS™ system (Pall Medical, Dreieich, Germany) represents a second, more sophisticated commercially available system.Organ protective effects, excellent control of sedation, and dose-dependent deep sedation while preserving spontaneous breathing with hardly any accumulation or induction of tolerance, make volatile anaesthetics an interesting alternative, especially for patients needing deep sedation or when intravenous drugs are no longer efficacious.But obviously, the outcome is most important. We know that deep intravenous sedation increases mortality, whereas inhalational sedation could prove beneficial. We now need prospective clinical trials examining mortality, but also the psychological outcome of those most critically ill patients sedated by inhalation or intravenously.
Collapse
Affiliation(s)
- A Meiser
- Klinik für Anästhesiologie, Intensivmedizin und Schmerztherapie, Universitätsklinikum des Saarlandes, Kirrberger Str. 1, 66421, Homburg/Saar, Deutschland.
| | - H Bomberg
- Klinik für Anästhesiologie, Intensivmedizin und Schmerztherapie, Universitätsklinikum des Saarlandes, Kirrberger Str. 1, 66421, Homburg/Saar, Deutschland
| | - T Volk
- Klinik für Anästhesiologie, Intensivmedizin und Schmerztherapie, Universitätsklinikum des Saarlandes, Kirrberger Str. 1, 66421, Homburg/Saar, Deutschland
| | - H V Groesdonk
- Klinik für Anästhesiologie, Intensivmedizin und Schmerztherapie, Universitätsklinikum des Saarlandes, Kirrberger Str. 1, 66421, Homburg/Saar, Deutschland
| |
Collapse
|
14
|
Karnjuš I, Mekiš D, Križmarić M. Uncontrolled delivery of liquid volatile anaesthetic when using the anaesthetic conserving device. J Clin Monit Comput 2017; 32:629-638. [PMID: 28567612 DOI: 10.1007/s10877-017-0022-2] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/21/2016] [Accepted: 04/24/2017] [Indexed: 11/30/2022]
Abstract
During patient sedation with liquid volatile anaesthetic, some problems may occur through a process called auto-pumping, defined as an expansion of bubbles inside the syringe, which can lead to uncontrolled anaesthetic delivery. The study examined how the temperature of liquid volatile anaesthetics (sevoflurane and isoflurane) and the presence of gas bubbles in the syringe affect the occurrence of auto-pumping when using the anaesthetic conserving device (ACD, AnaConDa™, Sedana Medical, Uppsala, Sweden). Four different circumstances for each volatile anaesthetic were tested with a bench study: volatile anaesthetic at room temperature or precooled with and without the presence of gas bubbles in the syringe. Liquid volatile anaesthetic was infused into the ACD via a syringe pump at a fixed rate and heated gradually until the temperature of the syringe surface reached 50 °C. A main-stream gas monitor was used to measure the expired fraction of volatile anaesthetic (FE vol%). The occurrence of auto-pumping was observed only in the subgroups containing gas bubbles, with both anaesthetics. In these subgroups, the values of the expired anaesthetic gas fraction increased dramatically with the expansion of gas bubbles in the syringe (ΔFE ranged from +1.6 to 2.4 vol% for sevoflurane and +2.3 to 3.4 vol% for isoflurane). Furthermore, when the heat source was removed, a substantial decline in anaesthetic agent values below the baseline was observed with both anaesthetics. The presence of gas bubbles in the syringe, especially when exposed to a heat source, may provoke auto-pumping with uncontrolled excessive anaesthetic delivery. If auto-pumping is suspected, the syringe pump must be stopped and the ACD removed from the breathing circuit at once.
Collapse
Affiliation(s)
- Igor Karnjuš
- Department of Nursing, Faculty of Health Sciences, University of Primorska, Polje 42, 6310, Izola, Slovenia.
| | - Dušan Mekiš
- Department of Anaesthesiology, Intensive Care and Pain Management, University Medical Centre Maribor, Ljubljanska ulica 5, 2000, Maribor, Slovenia.,Department of Anaesthesiology and Reanimation, Faculty of Medicine, University of Maribor, Taborska 8, 2000, Maribor, Slovenia
| | - Miljenko Križmarić
- Department of Anaesthesiology and Reanimation, Faculty of Medicine, University of Maribor, Taborska 8, 2000, Maribor, Slovenia.,Department of Bioinformatics, Faculty of Health Sciences, University of Maribor, Žitna ulica 15, 2000, Maribor, Slovenia
| |
Collapse
|
15
|
Jabaudon M, Boucher P, Imhoff E, Chabanne R, Faure JS, Roszyk L, Thibault S, Blondonnet R, Clairefond G, Guérin R, Perbet S, Cayot S, Godet T, Pereira B, Sapin V, Bazin JE, Futier E, Constantin JM. Sevoflurane for Sedation in Acute Respiratory Distress Syndrome. A Randomized Controlled Pilot Study. Am J Respir Crit Care Med 2017; 195:792-800. [DOI: 10.1164/rccm.201604-0686oc] [Citation(s) in RCA: 90] [Impact Index Per Article: 12.9] [Reference Citation Analysis] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/31/2022] Open
Affiliation(s)
- Matthieu Jabaudon
- Department of Perioperative Medicine
- Clermont Université, Université d'Auvergne, Clermont-Ferrand, France
| | | | | | | | | | - Laurence Roszyk
- Department of Medical Biochemistry and Molecular Biology, and
- Clermont Université, Université d'Auvergne, Clermont-Ferrand, France
| | - Sandrine Thibault
- Department of Clinical Research and Innovation (DRCI), CHU Clermont-Ferrand, Clermont-Ferrand, France; and
| | - Raiko Blondonnet
- Department of Perioperative Medicine
- Clermont Université, Université d'Auvergne, Clermont-Ferrand, France
| | - Gael Clairefond
- Clermont Université, Université d'Auvergne, Clermont-Ferrand, France
| | | | - Sébastien Perbet
- Department of Perioperative Medicine
- Clermont Université, Université d'Auvergne, Clermont-Ferrand, France
| | | | | | - Bruno Pereira
- Department of Clinical Research and Innovation (DRCI), CHU Clermont-Ferrand, Clermont-Ferrand, France; and
| | - Vincent Sapin
- Department of Medical Biochemistry and Molecular Biology, and
- Clermont Université, Université d'Auvergne, Clermont-Ferrand, France
| | | | - Emmanuel Futier
- Department of Perioperative Medicine
- Clermont Université, Université d'Auvergne, Clermont-Ferrand, France
| | - Jean-Michel Constantin
- Department of Perioperative Medicine
- Clermont Université, Université d'Auvergne, Clermont-Ferrand, France
| |
Collapse
|
16
|
Purrucker JC, Renzland J, Uhlmann L, Bruckner T, Hacke W, Steiner T, Bösel J. Volatile sedation with sevoflurane in intensive care patients with acute stroke or subarachnoid haemorrhage using AnaConDa®: an observational study. Br J Anaesth 2015; 114:934-43. [PMID: 25823541 DOI: 10.1093/bja/aev070] [Citation(s) in RCA: 38] [Impact Index Per Article: 4.2] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Accepted: 01/02/2015] [Indexed: 01/22/2023] Open
Abstract
BACKGROUND The anaesthetic conserving device, AnaConDa(®), allows use of inhaled anaesthetics for sedation in the intensive care unit. We prospectively measured cerebral and cardiopulmonary parameters in patients with acute stroke or subarachnoid haemorrhage during a switch from i.v. to inhalative sedation. METHODS 25 patients were switched from i.v. to an indefinite period of inhaled sedation with sevoflurane. Mean arterial (MAP), intracranial (ICP), and cerebral perfusion pressure (CPP), middle cerebral artery mean flow velocity (MFV) and fractional tissue oxygen extraction (FTOE), systemic cardiopulmonary parameters, and administered drugs were assessed before and after the change (-6 to +12 h). RESULTS In 8 patients, critically reduced MAP or ICP crisis led to premature termination of sevoflurane sedation. In the other 17 patients, after the first hour, mean ICP increased [2.4 (4.5) mm Hg; P=0.046], MAP decreased [7.8 (14.1) mm Hg; P=0.036] and thus CPP decreased also [-10.2 (15.1) mm Hg; P=0.014]. MFV and FTOE did not change. Over a 12 hour post switch observational period, [Formula: see text] increased slightly [0.3 (0.8) kPa; P=0.104], ICP did not change [0.2 (3.9) mm Hg; P=0.865], but MAP [-6 (6.9) mm Hg; P=0.002] and thus CPP decreased [-6 (8.5) mm Hg; P=0.010]. CONCLUSION Sevoflurane led to sufficient sedation, but decreased MAP and CPP in a selected cerebrovascular neurocritical care population. In about a third of these patients, severe adverse reactions, including intolerable ICP increases, were observed.
Collapse
Affiliation(s)
- J C Purrucker
- Department of Neurology, Heidelberg University Hospital, Heidelberg, Germany
| | - J Renzland
- Department of Neurology, Heidelberg University Hospital, Heidelberg, Germany
| | - L Uhlmann
- Department of Medical Biometry and Informatics, University of Heidelberg, Heidelberg, Germany
| | - T Bruckner
- Department of Medical Biometry and Informatics, University of Heidelberg, Heidelberg, Germany
| | - W Hacke
- Department of Neurology, Heidelberg University Hospital, Heidelberg, Germany
| | - T Steiner
- Department of Neurology, Heidelberg University Hospital, Heidelberg, Germany Department of Neurology, Frankfurt Hoechst Hospital, Frankfurt am Main, Germany
| | - J Bösel
- Department of Neurology, Heidelberg University Hospital, Heidelberg, Germany
| |
Collapse
|
17
|
Impact of the anesthetic conserving device on respiratory parameters and work of breathing in critically ill patients under light sedation with sevoflurane. Anesthesiology 2014; 121:808-16. [PMID: 25111218 DOI: 10.1097/aln.0000000000000394] [Citation(s) in RCA: 24] [Impact Index Per Article: 2.4] [Reference Citation Analysis] [Abstract] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/03/2023]
Abstract
BACKGROUND Sevoflurane sedation in the intensive care unit is possible with a special heat and moisture exchanger called the Anesthetic Conserving Device (ACD) (AnaConDa; Sedana Medical AB, Uppsala, Sweden). The ACD, however, may corrupt ventilatory mechanics when used during the weaning process of intensive care unit patients. The authors compared the ventilatory effects of light-sedation with sevoflurane administered with the ACD and those of classic management, consisting of a heated humidifier and intravenous sedation, in intensive care unit patients receiving pressure-support ventilation. METHODS Fifteen intensive care unit patients without chronic pulmonary disease were included. A target Richmond Agitation Sedation Scale level of -1/-2 was obtained with intravenous remifentanil (baseline 1-condition). Two successive interventions were tested: replacement of the heated humidifier by the ACD without sedation change (ACD-condition) and sevoflurane with the ACD with an identical target level (ACD-sevoflurane-condition). Patients finally returned to baseline (baseline 2-condition). Work of breathing, ventilatory patterns, blood gases, and tolerance were recorded. A steady state of 30 min was achieved for each experimental condition. RESULTS ACD alone worsened ventilatory parameters, with significant increases in work of breathing (from 1.7 ± 1.1 to 2.3 ± 1.2 J/l), minute ventilation, P0,1, intrinsic positive end-expiratory pressure (from 1.3 ± 2.6 to 4.7 ± 4.2 cm H2O), inspiratory pressure swings, and decreased patient comfort. Sevoflurane normalized work of breathing (from 2.3 ± 1.2 to 1.8 ± 1 J/l), intrinsic positive end-expiratory pressure (from 4.7 ± 4.2 to 1.8 ± 2 cm H2O), inspiratory pressure swings, other ventilatory parameters, and patient tolerance. CONCLUSIONS ACD increases work of breathing and worsens ventilatory parameters. Sevoflurane use via the ACD (for a light-sedation target) normalizes respiratory parameters. In this patient's population, light-sedation with sevoflurane and the ACD may be possible during the weaning process.
Collapse
|
18
|
Sturesson LW, Bodelsson M, Jonson B, Malmkvist G. Anaesthetic conserving device AnaConDa: dead space effect and significance for lung protective ventilation. Br J Anaesth 2014; 113:508-14. [PMID: 24871871 DOI: 10.1093/bja/aeu102] [Citation(s) in RCA: 23] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Abstract] [Key Words] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/18/2022] Open
Abstract
BACKGROUND The anaesthetic conserving device AnaConDa (ACD) reflects exhaled anaesthetic agents thereby facilitating the use of inhaled anaesthetic agents outside operating theatres. Expired CO₂ is, however, also reflected causing a dead space effect in excess of the ACD internal volume. CO₂ reflection from the ACD is attenuated by humidity. This study tests the hypothesis that sevoflurane further attenuates reflection of CO₂. An analysis of clinical implications of our findings was performed. METHODS Twelve postoperative patients received mechanical ventilation using a conventional heat and moisture exchanger (HME, internal volume 50 ml) and an ACD (100 ml), the latter with or without administration of sevoflurane. The ACD was also studied with a test lung at high sevoflurane concentrations. Reflection of CO₂ and dead space effects were evaluated with the single-breath test for CO2. RESULTS Sevoflurane reduced but did not abolish CO₂ reflection. In patients, the mean dead space effect with 0.8% sevoflurane was 88 ml larger using the ACD compared with the HME (P<0.001), of which 38 ml was due to CO₂ reflection. Our calculations show that with the use of the ACD, normocapnia cannot be achieved with tidal volume <6 ml kg(-1) even when respiratory rate is increased. CONCLUSIONS An ACD causes a dead space effect larger than its internal volume due to reflection of CO₂, which is attenuated but not abolished by sevoflurane administration. CO₂ reflection from the ACD limits its use with low tidal volume ventilation, such as with lung protection ventilation strategies. CLINICAL TRIAL REGISTRATION Clinical Trials NCT01699802.
Collapse
Affiliation(s)
- L W Sturesson
- Section of Anaesthesiology and Intensive Care, Lund University and Skane University Hospital, SE-221 85 Lund, Sweden
| | - M Bodelsson
- Section of Anaesthesiology and Intensive Care, Lund University and Skane University Hospital, SE-221 85 Lund, Sweden
| | - B Jonson
- Section of Clinical Physiology, Department of Clinical Sciences Lund, Lund University and Skane University Hospital, SE-221 85 Lund, Sweden
| | - G Malmkvist
- Section of Anaesthesiology and Intensive Care, Lund University and Skane University Hospital, SE-221 85 Lund, Sweden
| |
Collapse
|