1
|
Meng L, Hu Y, Li W, Zhou Z, Cui S, Wang M, Chen Z, Wu Q. Molecular Chain Rearrangement-Induced In Situ Formation of Nanofibers for Improving the Strength and Toughness of Hydrogels. ACS APPLIED MATERIALS & INTERFACES 2024; 16:53007-53021. [PMID: 39303004 DOI: 10.1021/acsami.4c13362] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 09/22/2024]
Abstract
Although poly(vinyl alcohol) (PVA) hydrogel has high elasticity and is suitable for cartilage tissue engineering, it is difficult to have both high strength and toughness. In this study, a simple and universal strategy is proposed to prepare strong and tough PVA hydrogels by in situ forming nanofibers on the original network structure induced by a molecular chain rearrangement. Quenching-tempering alteratively in ethanol and water several times is carried out to strengthen PVA hydrogels (PVA-Etn hydrogels) due to the advantages of noncovalent bonds in adjustability and reversibility. The results show that, after three quenching-tempering cycles, PVA-Et3 hydrogel with water content up to 79 wt % shows comprehensive improved mechanical properties. The compression modulus, tensile modulus, fracture strength, tensile strain, and tear energy of the PVA-Et3 hydrogel are 270, 250, 260, 130, and 180% of the initial PVA hydrogel, respectively. The improved mechanical properties of the PVA-Et3 hydrogel are attributed to the strong cross-linked PVA chains and hydrogen bond-reinforced nanofibers. This study not only provides a simple and efficient solution for the preparation of strong and tough polymer scaffolds in tissue engineering but also provides new insights for understanding the mechanism of improving the mechanical properties of polymer hydrogels by adjusting the molecular structure.
Collapse
Affiliation(s)
- Lihui Meng
- State Key Laboratory of Advanced Technology for Materials Synthesis and Processing, Wuhan University of Technology, Wuhan 430070, P. R. China
| | - Yanru Hu
- State Key Laboratory of Advanced Technology for Materials Synthesis and Processing, Wuhan University of Technology, Wuhan 430070, P. R. China
| | - Wenchao Li
- State Key Laboratory of Advanced Technology for Materials Synthesis and Processing, Wuhan University of Technology, Wuhan 430070, P. R. China
| | - Zilin Zhou
- State Key Laboratory of Advanced Technology for Materials Synthesis and Processing, Wuhan University of Technology, Wuhan 430070, P. R. China
| | - Shuojie Cui
- State Key Laboratory of Advanced Technology for Materials Synthesis and Processing, Wuhan University of Technology, Wuhan 430070, P. R. China
| | - Meng Wang
- State Key Laboratory of Advanced Technology for Materials Synthesis and Processing, Wuhan University of Technology, Wuhan 430070, P. R. China
| | - Zebin Chen
- Center of Hepato-Pancreato-Biliary Surgery, The First Affiliated Hospital, Sun Yat-sen University, Guangzhou 510080, P. R. China
| | - Qingzhi Wu
- State Key Laboratory of Advanced Technology for Materials Synthesis and Processing, Wuhan University of Technology, Wuhan 430070, P. R. China
| |
Collapse
|
2
|
Sahinis C, Kellis E. Distal hamstrings tendons mechanical properties at rest and contraction using free-hand 3-D ultrasonography. Scand J Med Sci Sports 2024; 34:e14621. [PMID: 38597348 DOI: 10.1111/sms.14621] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/05/2023] [Revised: 03/10/2024] [Accepted: 03/17/2024] [Indexed: 04/11/2024]
Abstract
Tendon properties impact human locomotion, influencing sports performance, and injury prevention. Hamstrings play a crucial role in sprinting, particularly the biceps femoris long head (BFlh), which is prone to frequent injuries. It remains uncertain if BFlh exhibits distinct mechanical properties compared to other hamstring muscles. This study utilized free-hand three-dimensional ultrasound to assess morphological and mechanical properties of distal hamstrings tendons in 15 men. Scans were taken in prone position, with hip and knee extended, at rest and during 20%, 40%, 60%, and 80% of maximal voluntary isometric contraction of the knee flexors. Tendon length, volume, cross-sectional area (CSA), and anteroposterior (AP) and mediolateral (ML) widths were quantified at three locations. Longitudinal and transverse deformations, stiffness, strain, and stress were estimated. The ST had the greatest tendon strain and the lowest stiffness as well as the highest CSA and AP and ML width strain compared to other tendons. Biceps femoris short head (BFsh) exhibited the least strain, AP and ML deformation. Further, BFlh displayed the highest stiffness and stress, and BFsh had the lowest stress. Additionally, deformation varied by region, with the proximal site showing generally the lowest CSA strain. Distal tendon mechanical properties differed among the hamstring muscles during isometric knee flexions. In contrast to other bi-articular hamstrings, the BFlh high stiffness and stress may result in greater energy absorption by its muscle fascicles, rather than the distal tendon, during late swing in sprinting. This could partly account for the increased incidence of hamstring injuries in this muscle.
Collapse
Affiliation(s)
- Chrysostomos Sahinis
- Department of Physical Education and Sport Sciences at Serres, Laboratory of Neuromechanics, Aristotle University of Thessaloniki, Serres, Greece
| | - Eleftherios Kellis
- Department of Physical Education and Sport Sciences at Serres, Laboratory of Neuromechanics, Aristotle University of Thessaloniki, Serres, Greece
| |
Collapse
|
3
|
Tsai L, Navarro P, Wu S, Levinson T, Mendoza E, Janneke Schwaner M, Daley MA, Azizi E, Ilton M. Viscoelastic materials are most energy efficient when loaded and unloaded at equal rates. J R Soc Interface 2024; 21:20230527. [PMID: 38290561 PMCID: PMC10827427 DOI: 10.1098/rsif.2023.0527] [Citation(s) in RCA: 1] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/11/2023] [Accepted: 01/04/2024] [Indexed: 02/01/2024] Open
Abstract
Biological springs can be used in nature for energy conservation and ultra-fast motion. The loading and unloading rates of elastic materials can play an important role in determining how the properties of these springs affect movements. We investigate the mechanical energy efficiency of biological springs (American bullfrog plantaris tendons and guinea fowl lateral gastrocnemius tendons) and synthetic elastomers. We measure these materials under symmetric rates (equal loading and unloading durations) and asymmetric rates (unequal loading and unloading durations) using novel dynamic mechanical analysis measurements. We find that mechanical efficiency is highest at symmetric rates and significantly decreases with a larger degree of asymmetry. A generalized one-dimensional Maxwell model with no fitting parameters captures the experimental results based on the independently characterized linear viscoelastic properties of the materials. The model further shows that a broader viscoelastic relaxation spectrum enhances the effect of rate-asymmetry on efficiency. Overall, our study provides valuable insights into the interplay between material properties and unloading dynamics in both biological and synthetic elastic systems.
Collapse
Affiliation(s)
- Lucien Tsai
- Department of Physics, Harvey Mudd College, Claremont, CA 91711, USA
| | - Paco Navarro
- Department of Physics, Harvey Mudd College, Claremont, CA 91711, USA
| | - Siqi Wu
- Department of Physics, Harvey Mudd College, Claremont, CA 91711, USA
| | - Taylor Levinson
- Department of Physics, Harvey Mudd College, Claremont, CA 91711, USA
| | - Elizabeth Mendoza
- Department of Ecology and Evolutionary Biology, University of California, Irvine, CA 92697, USA
| | - M. Janneke Schwaner
- Department of Ecology and Evolutionary Biology, University of California, Irvine, CA 92697, USA
| | - Monica A. Daley
- Department of Ecology and Evolutionary Biology, University of California, Irvine, CA 92697, USA
| | - Emanuel Azizi
- Department of Ecology and Evolutionary Biology, University of California, Irvine, CA 92697, USA
| | - Mark Ilton
- Department of Physics, Harvey Mudd College, Claremont, CA 91711, USA
| |
Collapse
|
4
|
Sun M, Li H, Hou Y, Huang N, Xia X, Zhu H, Xu Q, Lin Y, Xu L. Multifunctional tendon-mimetic hydrogels. SCIENCE ADVANCES 2023; 9:eade6973. [PMID: 36800416 PMCID: PMC9937573 DOI: 10.1126/sciadv.ade6973] [Citation(s) in RCA: 21] [Impact Index Per Article: 21.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 09/02/2022] [Accepted: 01/18/2023] [Indexed: 05/21/2023]
Abstract
We report multifunctional tendon-mimetic hydrogels constructed from anisotropic assembly of aramid nanofiber composites. The stiff nanofibers and soft polyvinyl alcohol in these anisotropic composite hydrogels (ACHs) mimic the structural interplay between aligned collagen fibers and proteoglycans in tendons. The ACHs exhibit a high modulus of ~1.1 GPa, strength of ~72 MPa, fracture toughness of 7333 J/m2, and many additional characteristics matching those of natural tendons, which was not achieved with previous synthetic hydrogels. The surfaces of ACHs were functionalized with bioactive molecules to present biophysical cues for the modulation of morphology, phenotypes, and other behaviors of attached cells. Moreover, soft bioelectronic components can be integrated on ACHs, enabling in situ sensing of various physiological parameters. The outstanding mechanics and functionality of these tendon mimetics suggest their further applications in advanced tissue engineering, implantable prosthetics, human-machine interactions, and other technologies.
Collapse
Affiliation(s)
- Mingze Sun
- Department of Mechanical Engineering, The University of Hong Kong, Hong Kong SAR, China
| | - Hegeng Li
- Department of Mechanical Engineering, The University of Hong Kong, Hong Kong SAR, China
| | - Yong Hou
- Department of Electrical and Electronic Engineering, The University of Hong Kong, Hong Kong SAR, China
| | - Nan Huang
- Department of Mechanical Engineering, The University of Hong Kong, Hong Kong SAR, China
| | - Xingyu Xia
- Department of Mechanical Engineering, The University of Hong Kong, Hong Kong SAR, China
| | - Hengjia Zhu
- Department of Mechanical Engineering, The University of Hong Kong, Hong Kong SAR, China
| | - Qin Xu
- Department of Physics, Faculty of Sciences, The Hong Kong University of Science and Technology, Hong Kong SAR, China
| | - Yuan Lin
- Department of Mechanical Engineering, The University of Hong Kong, Hong Kong SAR, China
- Advanced Biomedical Instrumentation Centre Limited, Hong Kong SAR, China
| | - Lizhi Xu
- Department of Mechanical Engineering, The University of Hong Kong, Hong Kong SAR, China
- Advanced Biomedical Instrumentation Centre Limited, Hong Kong SAR, China
| |
Collapse
|
5
|
Rojek K, Ćwiklińska M, Kuczak J, Guzowski J. Microfluidic Formulation of Topological Hydrogels for Microtissue Engineering. Chem Rev 2022; 122:16839-16909. [PMID: 36108106 PMCID: PMC9706502 DOI: 10.1021/acs.chemrev.1c00798] [Citation(s) in RCA: 36] [Impact Index Per Article: 18.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/15/2021] [Indexed: 02/07/2023]
Abstract
Microfluidics has recently emerged as a powerful tool in generation of submillimeter-sized cell aggregates capable of performing tissue-specific functions, so-called microtissues, for applications in drug testing, regenerative medicine, and cell therapies. In this work, we review the most recent advances in the field, with particular focus on the formulation of cell-encapsulating microgels of small "dimensionalities": "0D" (particles), "1D" (fibers), "2D" (sheets), etc., and with nontrivial internal topologies, typically consisting of multiple compartments loaded with different types of cells and/or biopolymers. Such structures, which we refer to as topological hydrogels or topological microgels (examples including core-shell or Janus microbeads and microfibers, hollow or porous microstructures, or granular hydrogels) can be precisely tailored with high reproducibility and throughput by using microfluidics and used to provide controlled "initial conditions" for cell proliferation and maturation into functional tissue-like microstructures. Microfluidic methods of formulation of topological biomaterials have enabled significant progress in engineering of miniature tissues and organs, such as pancreas, liver, muscle, bone, heart, neural tissue, or vasculature, as well as in fabrication of tailored microenvironments for stem-cell expansion and differentiation, or in cancer modeling, including generation of vascularized tumors for personalized drug testing. We review the available microfluidic fabrication methods by exploiting various cross-linking mechanisms and various routes toward compartmentalization and critically discuss the available tissue-specific applications. Finally, we list the remaining challenges such as simplification of the microfluidic workflow for its widespread use in biomedical research, bench-to-bedside transition including production upscaling, further in vivo validation, generation of more precise organ-like models, as well as incorporation of induced pluripotent stem cells as a step toward clinical applications.
Collapse
Affiliation(s)
- Katarzyna
O. Rojek
- Institute of Physical Chemistry, Polish Academy of Sciences, ul. Kasprzaka 44/52, 01-224 Warsaw, Poland
| | - Monika Ćwiklińska
- Institute of Physical Chemistry, Polish Academy of Sciences, ul. Kasprzaka 44/52, 01-224 Warsaw, Poland
| | - Julia Kuczak
- Institute of Physical Chemistry, Polish Academy of Sciences, ul. Kasprzaka 44/52, 01-224 Warsaw, Poland
| | - Jan Guzowski
- Institute of Physical Chemistry, Polish Academy of Sciences, ul. Kasprzaka 44/52, 01-224 Warsaw, Poland
| |
Collapse
|
6
|
Benage LG, Sweeney JD, Giers MB, Balasubramanian R. Dynamic Load Model Systems of Tendon Inflammation and Mechanobiology. Front Bioeng Biotechnol 2022; 10:896336. [PMID: 35910030 PMCID: PMC9335371 DOI: 10.3389/fbioe.2022.896336] [Citation(s) in RCA: 12] [Impact Index Per Article: 6.0] [Reference Citation Analysis] [Abstract] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/14/2022] [Accepted: 06/22/2022] [Indexed: 11/25/2022] Open
Abstract
Dynamic loading is a shared feature of tendon tissue homeostasis and pathology. Tendon cells have the inherent ability to sense mechanical loads that initiate molecular-level mechanotransduction pathways. While mature tendons require physiological mechanical loading in order to maintain and fine tune their extracellular matrix architecture, pathological loading initiates an inflammatory-mediated tissue repair pathway that may ultimately result in extracellular matrix dysregulation and tendon degeneration. The exact loading and inflammatory mechanisms involved in tendon healing and pathology is unclear although a precise understanding is imperative to improving therapeutic outcomes of tendon pathologies. Thus, various model systems have been designed to help elucidate the underlying mechanisms of tendon mechanobiology via mimicry of the in vivo tendon architecture and biomechanics. Recent development of model systems has focused on identifying mechanoresponses to various mechanical loading platforms. Less effort has been placed on identifying inflammatory pathways involved in tendon pathology etiology, though inflammation has been implicated in the onset of such chronic injuries. The focus of this work is to highlight the latest discoveries in tendon mechanobiology platforms and specifically identify the gaps for future work. An interdisciplinary approach is necessary to reveal the complex molecular interplay that leads to tendon pathologies and will ultimately identify potential regenerative therapeutic targets.
Collapse
Affiliation(s)
- Lindsay G. Benage
- School of Chemical, Biological and Environmental Engineering, Oregon State University, Corvallis, OR, United States
| | - James D. Sweeney
- School of Chemical, Biological and Environmental Engineering, Oregon State University, Corvallis, OR, United States
| | - Morgan B. Giers
- School of Chemical, Biological and Environmental Engineering, Oregon State University, Corvallis, OR, United States
- *Correspondence: Morgan B. Giers,
| | - Ravi Balasubramanian
- School of Chemical, Biological and Environmental Engineering, Oregon State University, Corvallis, OR, United States
- School of Mechanical, Industrial and Manufacturing Engineering, Oregon State University, Corvallis, OR, United States
| |
Collapse
|
7
|
Rehydration of the Tendon Fascicle Bundles Using Simulated Body Fluid Ensures Stable Mechanical Properties of the Samples. MATERIALS 2022; 15:ma15093033. [PMID: 35591368 PMCID: PMC9104251 DOI: 10.3390/ma15093033] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 01/30/2022] [Revised: 03/31/2022] [Accepted: 04/11/2022] [Indexed: 11/24/2022]
Abstract
In this work, we investigate the influence of dehydration and subsequent rehydration of tendon fascicle bundles on their structural and mechanical properties by using distilled water, 0.9% NaCl, 10% NaCl, SBF, and double concentrated SBF (SBFx2). The properties of tendon fascicle bundles were investigated by means of uniaxial tests with relaxation periods and hysteresis for samples with various interfascicular matrix content, dissected from the anterior and posterior areas of bovine tendon. Uniaxial tests with relaxation periods and analysis of sample geometry and weight showed that dehydration alters the modulus of elasticity dependent on the interfascicular matrix content and influences the viscoelastic properties of tendon fascicle bundles. Tensile and relaxation tests revealed that changes resulting from excessive sample drying can be reversed by rehydration in an SBF bath solution for elastic strain range above the toe region. Rehydration in SBF solution led to minor differences in mechanical properties when compared to control samples. Moreover, anterior samples with greater interfascicular matrix content, despite their lower stiffness, are less sensitive to sample drying. The obtained results allow us to limit the discrepancies in the measurement of mechanical properties of wet biological samples and can be useful to researchers investigating soft tissue mechanics and the stability of transplant materials.
Collapse
|
8
|
McBride JM. Muscle Actuators, Not Springs, Drive Maximal Effort Human Locomotor Performance. J Sports Sci Med 2021; 20:766-777. [PMID: 35321123 PMCID: PMC8488820 DOI: 10.52082/jssm.2021.766] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/03/2021] [Accepted: 09/20/2021] [Indexed: 05/19/2023]
Abstract
The current investigation examined muscle-tendon unit kinematics and kinetics in human participants asked to perform a hopping task for maximal performance with variational preceding milieu. Twenty-four participants were allocated post-data collection into those participants with an average hop height of higher (HH) or lower (LH) than 0.1 m. Participants were placed on a customized sled at a 20º angle while standing on a force plate. Participants used their dominant ankle for all testing and their knee was immobilized and thus all movement involved only the ankle joint and corresponding propulsive unit (triceps surae muscle complex). Participants were asked to perform a maximal effort during a single dynamic countermovement hop (CMH) and drop hops from 10 cm (DH10) and 50 cm (DH50). Three-dimensional motion analysis was performed by utilizing an infrared camera VICON motion analysis system and a corresponding force plate. An ultrasound probe was placed on the triceps surae muscle complex for muscle fascicle imaging. HH hopped significantly higher in all hopping tasks in comparison to LH. In addition, the HH group concentric ankle work was significantly higher in comparison to LH during all of the hopping tasks. Active muscle work was significantly higher in HH in comparison to LH as well. Tendon work was not significantly different between HH and LH. Active muscle work was significantly correlated with hopping height (r = 0.97) across both groups and hopping tasks and contributed more than 50% of the total work. The data indicates that humans primarily use a motor-driven system and thus it is concluded that muscle actuators and not springs maximize performance in hopping locomotor tasks in humans.
Collapse
Affiliation(s)
- Jeffrey M McBride
- Neuromuscular & Biomechanics Laboratory, Beaver College of Health Sciences, Department of Health & Exercise Science, Appalachian State University, North Carolina, USA
| |
Collapse
|
9
|
Crites S, Joumaa V, Rios JL, Sawatsky A, Hart DA, Reimer RA, Herzog W. Moderate aerobic exercise, but not dietary prebiotic fibre, attenuates losses to mechanical property integrity of tail tendons in a rat model of diet-induced obesity. J Biomech 2021; 129:110798. [PMID: 34700144 DOI: 10.1016/j.jbiomech.2021.110798] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/03/2021] [Revised: 08/26/2021] [Accepted: 10/03/2021] [Indexed: 10/20/2022]
Abstract
The purpose of this study was to investigate the alterations with obesity, and the effects of moderate aerobic exercise or prebiotic dietary-fibre supplementation on the mechanical and biochemical properties of the tail tendon in a rat model of high-fat/high-sucrose (HFS) diet-induced obesity. Thirty-two male Sprague-Dawley rats were randomized to chow (n = 8) or HFS (n = 24) diets. After 12-weeks, the HFS fed rats were further randomized into sedentary (HFS sedentary, n = 8), exercise (HFS + E, n = 8) or prebiotic fibre supplementation (HFS + F, n = 8) groups. After another 12-weeks, rats were sacrificed, and one tail tendon was isolated and tested. Stress-relaxation and stretch-to-failure tests were performed to determine mechanical properties (peak, steady-state, yield and failure stresses, Young's modulus, and yield and failure strains) of the tendons. The hydroxyproline content was also analyzed. The HFS sedentary and HFS + F groups had higher final body masses and fat percentages compared to the chow and HFS + E groups. Yield strain was reduced in the HFS sedentary rats compared to the chow rats. Peak and steady-state stresses, failure strain, Young's modulus, and hydroxyproline content were not different across groups. Although the HFS + E group showed higher failure stress, yield stress, and yield strain compared to the HFS sedentary group, HFS + F animals did not produce differences in the properties of the tail tendon compared to the HFS sedentary group. These results indicate that exposure to a HFS diet led to a reduction in the yield strain of the tail tendon and aerobic exercise, but not fibre supplementation, attenuated these diet-related alterations to tendon integrity.
Collapse
Affiliation(s)
- Stephanie Crites
- Human Performance Laboratory, Faculty of Kinesiology, University of Calgary, Calgary, AB, Canada
| | - Venus Joumaa
- Human Performance Laboratory, Faculty of Kinesiology, University of Calgary, Calgary, AB, Canada; McCaig Institute for Bone and Joint Health, University of Calgary, Calgary, AB, Canada.
| | - Jaqueline L Rios
- Human Performance Laboratory, Faculty of Kinesiology, University of Calgary, Calgary, AB, Canada; McCaig Institute for Bone and Joint Health, University of Calgary, Calgary, AB, Canada; Regenerative Medicine Center Utrecht, University Medical Center Utrecht, Utrecht, Netherland
| | - Andrew Sawatsky
- Human Performance Laboratory, Faculty of Kinesiology, University of Calgary, Calgary, AB, Canada; McCaig Institute for Bone and Joint Health, University of Calgary, Calgary, AB, Canada
| | - David A Hart
- Human Performance Laboratory, Faculty of Kinesiology, University of Calgary, Calgary, AB, Canada; McCaig Institute for Bone and Joint Health, University of Calgary, Calgary, AB, Canada
| | - Raylene A Reimer
- Human Performance Laboratory, Faculty of Kinesiology, University of Calgary, Calgary, AB, Canada; McCaig Institute for Bone and Joint Health, University of Calgary, Calgary, AB, Canada; Department of Biochemistry and Molecular Biology, Cumming School of Medicine, University of Calgary, Calgary, AB, Canada
| | - Walter Herzog
- Human Performance Laboratory, Faculty of Kinesiology, University of Calgary, Calgary, AB, Canada; McCaig Institute for Bone and Joint Health, University of Calgary, Calgary, AB, Canada
| |
Collapse
|
10
|
Ryan C, Pugliese E, Shologu N, Gaspar D, Rooney P, Islam MN, O'Riordan A, Biggs M, Griffin M, Zeugolis D. A combined physicochemical approach towards human tenocyte phenotype maintenance. Mater Today Bio 2021; 12:100130. [PMID: 34632361 PMCID: PMC8488312 DOI: 10.1016/j.mtbio.2021.100130] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/21/2021] [Revised: 08/27/2021] [Accepted: 08/28/2021] [Indexed: 02/08/2023] Open
Abstract
During in vitro culture, bereft of their optimal tissue context, tenocytes lose their phenotype and function. Considering that tenocytes in their native tissue milieu are exposed simultaneously to manifold signals, combination approaches (e.g. growth factor supplementation and mechanical stimulation) are continuously gaining pace to control cell fate during in vitro expansion, albeit with limited success due to the literally infinite number of possible permutations. In this work, we assessed the potential of scalable and potent physicochemical approaches that control cell fate (substrate stiffness, anisotropic surface topography, collagen type I coating) and enhance extracellular matrix deposition (macromolecular crowding) in maintaining human tenocyte phenotype in culture. Cell morphology was primarily responsive to surface topography. The tissue culture plastic induced the largest nuclei area, the lowest aspect ratio, and the highest focal adhesion kinase. Collagen type I coating increased cell number and metabolic activity. Cell viability was not affected by any of the variables assessed. Macromolecular crowding intensely enhanced and accelerated native extracellular matrix deposition, albeit not in an aligned fashion, even on the grooved substrates. Gene analysis at day 14 revealed that the 130 kPa grooved substrate without collagen type I coating and under macromolecular crowding conditions positively regulated human tenocyte phenotype. Collectively, this work illustrates the beneficial effects of combined physicochemical approaches in controlling cell fate during in vitro expansion.
Collapse
Affiliation(s)
- C.N.M. Ryan
- Regenerative, Modular & Developmental Engineering Laboratory (REMODEL), Biomedical Sciences Building, National University of Ireland Galway (NUI Galway), Galway, Ireland
- Science Foundation Ireland (SFI) Centre for Research in Medical Devices (CÚRAM), Biomedical Sciences Building, National University of Ireland Galway (NUI Galway), Galway, Ireland
| | - E. Pugliese
- Regenerative, Modular & Developmental Engineering Laboratory (REMODEL), Biomedical Sciences Building, National University of Ireland Galway (NUI Galway), Galway, Ireland
- Science Foundation Ireland (SFI) Centre for Research in Medical Devices (CÚRAM), Biomedical Sciences Building, National University of Ireland Galway (NUI Galway), Galway, Ireland
| | - N. Shologu
- Regenerative, Modular & Developmental Engineering Laboratory (REMODEL), Biomedical Sciences Building, National University of Ireland Galway (NUI Galway), Galway, Ireland
- Science Foundation Ireland (SFI) Centre for Research in Medical Devices (CÚRAM), Biomedical Sciences Building, National University of Ireland Galway (NUI Galway), Galway, Ireland
| | - D. Gaspar
- Regenerative, Modular & Developmental Engineering Laboratory (REMODEL), Biomedical Sciences Building, National University of Ireland Galway (NUI Galway), Galway, Ireland
- Science Foundation Ireland (SFI) Centre for Research in Medical Devices (CÚRAM), Biomedical Sciences Building, National University of Ireland Galway (NUI Galway), Galway, Ireland
| | - P. Rooney
- Science Foundation Ireland (SFI) Centre for Research in Medical Devices (CÚRAM), Biomedical Sciences Building, National University of Ireland Galway (NUI Galway), Galway, Ireland
| | - Md N. Islam
- Science Foundation Ireland (SFI) Centre for Research in Medical Devices (CÚRAM), Biomedical Sciences Building, National University of Ireland Galway (NUI Galway), Galway, Ireland
- Regenerative Medicine Institute (REMEDI), School of Medicine, Biomedical Sciences Building, National University of Ireland Galway (NUI Galway), Galway, Ireland
- Discipline of Biochemistry, School of Natural Sciences, National University of Ireland Galway (NUI Galway), Galway, Ireland
| | - A. O'Riordan
- Tyndall National Institute, University College Cork (UCC), Cork, Ireland
| | - M.J. Biggs
- Science Foundation Ireland (SFI) Centre for Research in Medical Devices (CÚRAM), Biomedical Sciences Building, National University of Ireland Galway (NUI Galway), Galway, Ireland
| | - M.D. Griffin
- Science Foundation Ireland (SFI) Centre for Research in Medical Devices (CÚRAM), Biomedical Sciences Building, National University of Ireland Galway (NUI Galway), Galway, Ireland
- Regenerative Medicine Institute (REMEDI), School of Medicine, Biomedical Sciences Building, National University of Ireland Galway (NUI Galway), Galway, Ireland
| | - D.I. Zeugolis
- Regenerative, Modular & Developmental Engineering Laboratory (REMODEL), Biomedical Sciences Building, National University of Ireland Galway (NUI Galway), Galway, Ireland
- Science Foundation Ireland (SFI) Centre for Research in Medical Devices (CÚRAM), Biomedical Sciences Building, National University of Ireland Galway (NUI Galway), Galway, Ireland
- Regenerative, Modular & Developmental Engineering Laboratory (REMODEL), Charles Institute of Dermatology, Conway Institute of Biomolecular & Biomedical Research and School of Mechanical & Materials Engineering, University College Dublin (UCD), Dublin, Ireland
| |
Collapse
|
11
|
Bones of teleost fish demonstrate high fracture strain. J Biomech 2021; 120:110341. [PMID: 33743397 DOI: 10.1016/j.jbiomech.2021.110341] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/30/2020] [Revised: 01/04/2021] [Accepted: 02/12/2021] [Indexed: 11/22/2022]
Abstract
The endoskeleton of teleosts (bony fish) includes a vertebral spine with articulating rib bones (RBs) similar to humans and further encompasses mineralized tissues that are not found in mammals, including intermuscular bones (IBs). RBs form through endochondral ossification and protect the inner organs, and IBs form through intramembranous ossification within the myosepta and play a role in force transmission and propulsion during locomotion. Based on previous findings suggesting that IBs show a much higher ability for fracture strain compared to mammalian bones, this study aims to investigate whether this ability is general to teleost bones or specific to IBs. We analyzed RBs and IBs of 25 North Atlantic Herring fish. RBs were analyzed using micro-mechanical tensile testing and micro-computed tomography, and both RB and IB were additionally analyzed with Raman spectroscopy. Based on our previous results from IB, we found that RBs are more elastically deformable (on average, 50% higher yield strain and 115% higher elastic work) and stronger (55% higher fracture stress) than values reported for IBs. However, these differences were neither associated with a higher Young's modulus nor a higher degree of mineralization in RBs. Astonishingly, RBs and IBs showed similar fracture strains (12-15% on average, reaching up to 20%), reflecting a much higher ability for tensile deformation than reported for mammalian bone, and further highlighting the biomimetic potential of teleost fish bones for inspiring innovative biomaterials.
Collapse
|
12
|
Zielinska N, Szewczyk B, Tubbs RS, Olewnik Ł. Coexistence of two accessory flexor pollicis longus heads or coexistence of two-headed flexor pollicis longus with an unrecognized anatomical structure? Surg Radiol Anat 2021; 43:763-769. [PMID: 33656594 PMCID: PMC8105208 DOI: 10.1007/s00276-021-02721-w] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/16/2020] [Accepted: 02/18/2021] [Indexed: 02/01/2023]
Abstract
The flexor pollicis longus (FPL) is located in the anterior compartment of the forearm. It is morphologically variable in both point of origin and insertion. An additional head of the FPL can lead to anterior interosseous syndrome. This report presents a morphological variation of the FPL (additional head in proximal attachment and bifurcated tendinous insertion in distal attachment) and an unrecognized structure that has not so far been described in the literature. This structure originates in six heads (attached to the FPL or interosseous membrane) that merge together, and inserts on to the FPL. All the variations noted have clinical significance, ranging from potential nerve compression to prevention of tendon rupture.
Collapse
Affiliation(s)
- Nicol Zielinska
- Department of Anatomical Dissection and Donation, Medical University of Lodz, Lodz, Poland
| | - Bartłomiej Szewczyk
- Department of Anatomical Dissection and Donation, Medical University of Lodz, Lodz, Poland
| | - R. Shane Tubbs
- Department of Neurosurgery, Tulane University School of Medicine, New Orleans, LA USA
- Department of Neurosurgery and Ochsner Neuroscience Institute, Ochsner Health System, New Orleans, LA USA
- Department of Anatomical Sciences, St. George’s University, West Indies, Grenada
| | - Łukasz Olewnik
- Department of Anatomical Dissection and Donation, Medical University of Lodz, Lodz, Poland
| |
Collapse
|
13
|
Javidi M, McGowan CP, Lin DC. Estimation of the force-velocity properties of individual muscles from measurement of the combined plantarflexor properties. J Exp Biol 2020; 223:jeb219980. [PMID: 32680898 DOI: 10.1242/jeb.219980] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/10/2019] [Accepted: 07/13/2020] [Indexed: 11/20/2022]
Abstract
The force-velocity (F-V) properties of isolated muscles or muscle fibers have been well studied in humans and other animals. However, determining properties of individual muscles in vivo remains a challenge because muscles usually function within a synergistic group. Modeling has been used to estimate the properties of an individual muscle from the experimental measurement of the muscle group properties. While this approach can be valuable, the models and the associated predictions are difficult to validate. In this study, we measured the in situ F-V properties of the maximally activated kangaroo rat plantarflexor group and used two different assumptions and associated models to estimate the properties of the individual plantarflexors. The first model (Mdl1) assumed that the percent contributions of individual muscles to group force and power were based upon the muscles' cross-sectional area and were constant across the different isotonic loads applied to the muscle group. The second model (Mdl2) assumed that the F-V properties of the fibers within each muscle were identical, but because of differences in muscle architecture, the muscles' contributions to the group properties changed with isotonic load. We compared the two model predictions with independent estimates of the muscles' contributions based upon sonomicrometry measurements of muscle length. We found that predictions from Mdl2 were not significantly different from sonomicrometry-based estimates while those from Mdl1 were significantly different. The results of this study show that incorporating appropriate fiber properties and muscle architecture is necessary to parse the individual muscles' contributions to the group F-V properties.
Collapse
Affiliation(s)
- Mehrdad Javidi
- Voiland School of Chemical Engineering and Bioengineering, Washington State University, PO Box 646515, Pullman, WA 99164, USA
| | - Craig P McGowan
- Department of Biological Sciences, University of Idaho, 875 Perimeter Drive, MS 3051, Moscow, ID 83844, USA
- WWAMI Medical Education Program, University of Idaho, 875 Perimeter Drive, MS 4207, Moscow, ID 83844, USA
- Washington Center for Muscle Biology, Washington State University, PO Box 646515, Pullman, WA 99164, USA
| | - David C Lin
- Voiland School of Chemical Engineering and Bioengineering, Washington State University, PO Box 646515, Pullman, WA 99164, USA
- Washington Center for Muscle Biology, Washington State University, PO Box 646515, Pullman, WA 99164, USA
- Department of Integrative Physiology and Neuroscience, Washington State University, PO Box 647620, Pullman, WA 99164, USA
| |
Collapse
|
14
|
Wiesinger HP, Seynnes OR, Kösters A, Müller E, Rieder F. Mechanical and Material Tendon Properties in Patients With Proximal Patellar Tendinopathy. Front Physiol 2020; 11:704. [PMID: 32733263 PMCID: PMC7358637 DOI: 10.3389/fphys.2020.00704] [Citation(s) in RCA: 21] [Impact Index Per Article: 5.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/02/2020] [Accepted: 05/28/2020] [Indexed: 01/20/2023] Open
Abstract
Introduction The effect of chronic patellar tendinopathy on tissue function and integrity is currently unclear and underinvestigated. The aim of this cohort comparison was to examine morphological, material, and mechanical properties of the patellar tendon and to extend earlier findings by measuring the ability to store and return elastic energy in symptomatic tendons. Methods Seventeen patients with chronic (>3 months, VISA-P < 80), inferior pole patellar tendinopathy (24 ± 4 years; male = 12, female = 5) were carefully matched to controls (25 ± 3 years) for training status, pattern, and history of loading of the patellar tendon. Individual knee extension force, patellar tendon stiffness, stress, strain, Young’s modulus, hysteresis, and energy storage capacity, were obtained with combined dynamometry, ultrasonography, magnetic resonance imaging, and electromyography. Results Anthropometric parameters did not differ between groups. VISA-P scores ranged from 28 to 78 points, and symptoms had lasted from 10 to 120 months before testing. Tendon proximal cross-sectional area was 61% larger in the patellar tendinopathy group than in the control group. There were no differences between groups in maximal voluntary isometric knee extension torque (p = 0.216; d < −0.31) nor in tensile tendon force produced during isometric ramp contractions (p = 0.185; d < −0.34). Similarly, tendon strain (p = 0.634; d < 0.12), hysteresis (p = 0.461; d < 0.18), and strain energy storage (p = 0.656; d < 0.36) did not differ between groups. However, patellar tendon stiffness (−19%; p = 0.007; d < −0.74), stress (−27%; p< 0.002; d < −0.90) and Young’s modulus (−32%; p = 0.001; d < −0.94) were significantly lower in tendinopathic patients compared to healthy controls. Discussion In this study, we observed lower stiffness in affected tendons. However, despite the substantial structural and histological changes occurring with tendinopathy, the tendon capacity to store and dissipate energy did not differ significantly.
Collapse
Affiliation(s)
- Hans-Peter Wiesinger
- Department of Sport and Exercise Science, University of Salzburg, Salzburg, Austria
| | - Olivier R Seynnes
- Department of Physical Performance, Norwegian School of Sport Sciences, Oslo, Norway
| | - Alexander Kösters
- Department of Sport and Exercise Science, University of Salzburg, Salzburg, Austria
| | - Erich Müller
- Department of Sport and Exercise Science, University of Salzburg, Salzburg, Austria
| | - Florian Rieder
- Department of Sport and Exercise Science, University of Salzburg, Salzburg, Austria.,Institute of Physical Medicine and Rehabilitation, Paracelsus Medical University, Salzburg, Austria
| |
Collapse
|
15
|
Rosario MV, Roberts TJ. Loading Rate Has Little Influence on Tendon Fascicle Mechanics. Front Physiol 2020; 11:255. [PMID: 32265742 PMCID: PMC7105874 DOI: 10.3389/fphys.2020.00255] [Citation(s) in RCA: 9] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/09/2019] [Accepted: 03/05/2020] [Indexed: 11/13/2022] Open
Abstract
Mechanically, tendons behave like springs and store energy by stretching in proportion to applied stress. This relationship is potentially modified by the rate at which stress is applied, a phenomenon known as viscosity. Viscoelasticity, the combined effects of elasticity and viscosity, can affect maximum strain, the amount of stored energy, and the proportion of energy recovered (resilience). Previous studies of tendons have investigated the functional effects of viscoelasticity, but not at the intermediate durations of loading that are known to occur in fast locomotor events. In this study, we isolated tendon fascicles from rat tails and performed force-controlled tensile tests at rates between ∼10 MPa s–1 to ∼80 MPa s–1. At high rates of applied stress, we found that tendon fascicles strained less, stored less energy, and were more resilient than at low rates of stress (p = 0.007, p = 0.040, and p = 0.004, respectively). The measured changes, however, were very small across the range of strain rates studied. For example, the average strain for the slowest loading rate was 0.637% while it was 0.614% for the fastest loading. We conclude that although there is a measurable effect of loading rate on tendon mechanics, the effect is small and can be largely ignored in the context of muscle-actuated locomotion, with the possible exception of extreme muscle-tendon morphologies.
Collapse
Affiliation(s)
- Michael V Rosario
- Department of Ecology and Evolutionary Biology, Brown University, Providence, RI, United States.,Department of Biology, West Chester University, West Chester, PA, United States
| | - Thomas J Roberts
- Department of Ecology and Evolutionary Biology, Brown University, Providence, RI, United States
| |
Collapse
|
16
|
Mendoza E, Azizi E, Moen DS. What explains vast differences in jumping power within a clade? Diversity, ecology and evolution of anuran jumping power. Funct Ecol 2020. [DOI: 10.1111/1365-2435.13545] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/30/2023]
Affiliation(s)
- Elizabeth Mendoza
- Department of Ecology and Evolutionary Biology University of California Irvine CA USA
- Department of Integrative Biology Oklahoma State University Stillwater OK USA
| | - Emanuel Azizi
- Department of Ecology and Evolutionary Biology University of California Irvine CA USA
| | - Daniel S. Moen
- Department of Integrative Biology Oklahoma State University Stillwater OK USA
| |
Collapse
|
17
|
Muszyński S, Świątkiewicz S, Arczewska-Włosek A, Dobrowolski P, Valverde Piedra JL, Arciszewski MB, Szymańczyk S, Zacharko-Siembida A, Kowalik S, Hułas-Stasiak M, Tomczyk-Warunek A, Schwarz T, Tomaszewska E. Analysis of mechanical properties of bones and tendons shows that modern hybrid rye can be introduced to corn-wheat based diet in broiler chickens as an alternative energy source irrespective of xylanase supplementation. Poult Sci 2020; 98:5613-5621. [PMID: 31222275 DOI: 10.3382/ps/pez323] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/01/2019] [Accepted: 05/21/2019] [Indexed: 12/31/2022] Open
Abstract
This study focused on analyzing the effects of inclusion of modern hybrid rye to corn-wheat diet on mechanical properties of bones and tendons. A total of 224 broiler chickens were fed a diet without rye inclusion or a diet containing 15% of hybrid rye cv. Brasetto. The diets were either unsupplemented or supplemented with xylanase (minimum activity 1000 FXU/g, dose 200 mg/kg of feed). Each dietary group consisted of 56 birds. On day 42, selected chickens (n = 7 from each group) were slaughtered. Tibia were analyzed for mineralization, geometry, and biomechanical characteristics of bone mid-diaphysis. The mechanical properties of digital flexor III tendon were also assessed. Bone mineral density and bone ash percentage did not differ when both diets were given without xylanase. Enzyme supplementation increased bone mineral density (P < 0.01) in both dietary groups, whereas bone ash percentage (P < 0.01) increased only for corn-wheat diet. Rye inclusion had no effect on bone mid-shaft geometrical traits related to tibia weight-bearing capacity (cross-sectional area, cortical index, and mean relative wall thickness). Performed bending test showed no effect of hybrid rye inclusion on bone mechanical endurance. When xylanase was supplemented, bone length (P < 0.01) and weight (P < 0.05) decreased, whereas yield load (P < 0.01), stiffness (P < 0.05), Young modulus (P < 0.05), elastics stress (P < 0.01), and ultimate stress (P < 0.01) increased, irrespective of rye presence. The tendon tensile strain test showed that in corn-wheat diet enzyme supplementation positively influenced rupture force (P < 0.05) and tendon stiffness (P < 0.01). Xylanase supplementation increased the value of energy required to tendon rupture, irrespective of rye inclusion (P < 0.05). Study showed that modern hybrid rye varieties can be introduced to corn-wheat diets of broiler chickens in the aspect of animal welfare related to the development and homeostasis of musculoskeletal system, irrespective of xylanase supplementation. The enzyme addition positively affected biomechanical properties of bones and tendons.
Collapse
Affiliation(s)
- S Muszyński
- Department of Biophysics, University of Life Sciences in Lublin, 20-950 Lublin, Poland
| | - S Świątkiewicz
- Department of Nutrition Physiology, National Research Institute of Animal Production, 32-083 Balice, Poland
| | - A Arczewska-Włosek
- Department of Nutrition Physiology, National Research Institute of Animal Production, 32-083 Balice, Poland
| | - P Dobrowolski
- Department of Comparative Anatomy and Anthropology, Maria Curie-Skłodowska University, 20-400 Lublin, Poland
| | - J L Valverde Piedra
- Department of Preclinical Veterinary Sciences, University of Life Sciences in Lublin, 20-950 Lublin, Poland
| | - M B Arciszewski
- Department of Animal Anatomy and Histology, University of Life Sciences in Lublin, 20-950 Lublin, Poland
| | - S Szymańczyk
- Department of Animal Physiology, University of Life Sciences in Lublin, 20-950 Lublin, Poland
| | - A Zacharko-Siembida
- Department of Animal Anatomy and Histology, University of Life Sciences in Lublin, 20-950 Lublin, Poland
| | - S Kowalik
- Department of Animal Physiology, University of Life Sciences in Lublin, 20-950 Lublin, Poland
| | - M Hułas-Stasiak
- Department of Comparative Anatomy and Anthropology, Maria Curie-Skłodowska University, 20-400 Lublin, Poland
| | - A Tomczyk-Warunek
- Locomotor System Research Department, Chair and Department of Rehabilitation and Orthopaedics, Medical University in Lublin, 20-090 Lublin, Poland
| | - T Schwarz
- Department of Swine and Small Animal Breeding, University of Agriculture in Kraków, 30-059 Cracow, Poland
| | - E Tomaszewska
- Department of Animal Physiology, University of Life Sciences in Lublin, 20-950 Lublin, Poland
| |
Collapse
|
18
|
|
19
|
Channon SB, Young IS, Cordner B, Swann N. Ontogenetic scaling of pelvic limb muscles, tendons and locomotor economy in the ostrich ( Struthio camelus). ACTA ACUST UNITED AC 2019; 222:jeb.182741. [PMID: 31350301 DOI: 10.1242/jeb.182741] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/13/2018] [Accepted: 07/23/2019] [Indexed: 01/14/2023]
Abstract
In rapidly growing animals there are numerous selective pressures and developmental constraints underpinning the ontogenetic development of muscle-tendon morphology and mechanical properties. Muscle force generating capacity, tendon stiffness, elastic energy storage capacity and efficiency were calculated from muscle and tendon morphological parameters and in vitro tendon mechanical properties obtained from a growth series of ostrich cadavers. Ontogenetic scaling relationships were established using reduced major axis regression analysis. Ostrich pelvic limb muscle mass and cross-sectional area broadly scaled with positive allometry, indicating maintained or relatively greater capacity for maximum isometric force generation in larger animals. The length of distal limb tendons was found to scale with positive allometry in several tendons associated with antigravity support and elastic energy storage during locomotion. Distal limb tendon stiffness scaled with negative allometry with respect to body mass, with tendons being relatively more compliant in larger birds. Tendon material properties also appeared to be size-dependent, suggesting that the relative increased compliance of tendons in larger ostriches is due in part to compensatory distortions in tendon material properties during maturation and development, not simply from ontogenetic changes in tendon geometry. Our results suggest that the previously reported increase in locomotor economy through ontogeny in the ostrich is due to greater potential for elastic energy storage with increasing body size. In fact, the rate of this increase may be somewhat greater than the conservative predictions of previous studies, thus illustrating the biological importance of elastic tendon structures in adult ostriches.
Collapse
Affiliation(s)
- Sarah B Channon
- Department of Comparative Biomedical Sciences, Royal Veterinary College, Royal College Street, London NW1 0TU, UK
| | - Iain S Young
- Institute of Integrative Biology, Department of Functional and Comparative Genomics, University of Liverpool, Liverpool L69 7ZB, UK
| | - Beckie Cordner
- Department of Comparative Biomedical Sciences, Royal Veterinary College, Royal College Street, London NW1 0TU, UK
| | - Nicola Swann
- Nicola Swann, Department of Applied and Human Sciences, Faculty of Science, Engineering and Computing, Kingston University London, Kingston-on-Thames KT1 2EE, UK
| |
Collapse
|
20
|
Fiedler IAK, Zeveleva S, Duarte A, Zhao X, Depalle B, Cardoso L, Jin S, Berteau JP. Microstructure, mineral and mechanical properties of teleost intermuscular bones. J Biomech 2019; 94:59-66. [PMID: 31427091 DOI: 10.1016/j.jbiomech.2019.07.009] [Citation(s) in RCA: 9] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/04/2018] [Revised: 06/12/2019] [Accepted: 07/09/2019] [Indexed: 12/12/2022]
Abstract
There is an increasing interest in understanding teleost bone biomechanics in several scientific communities, for instance as interesting biomaterials with specific structure-function relationships. Intermuscular bones of teleost fish have previously been described to play a role in the mechanical force transmission between muscle and bone, but their biomechanical properties are not yet fully described. Here, we have investigated intermuscular bones (IBs) of the North Atlantic Herring with regard to their structure and micro-architecture, mineral-related properties, and micro-mechanical tensile properties. A total of 115 IBs from 18 fish were investigated. One cohort of IBs, containing 20 bones from 2 smaller fish and 23 bones of 3 larger fish, was used for mechanical testing, wide-angle X-ray scattering, and scanning electron microscopy. Another cohort, containing 36 bones from 7 smaller fish and 36 bones from 6 larger fish, was used for microCT. Results show some astonishing properties of the IBs: (i) IBs present higher ductility, lower Young's modulus but similar strength and TMD (Tissue Mineral Density) compared to mammalian bone, and (ii) IBs from small fish were 49% higher in Young's modulus than fish bones from larger fish while their TMD was not statistically different and crystal length was 8% higher in large fish bones. Our results revealed that teleost IB presents a hybrid nature of soft and hard tissue that differs from other bone types, which might be associated with their evolution from mineralized tendons. This study provides new data regarding teleost fish bone biomechanical and micro-structural properties.
Collapse
Affiliation(s)
- I A K Fiedler
- Department of Physical Therapy, City University of New York - College of Staten Island, USA; Department of Osteology and Biomechanics, University Medical Center Hamburg Eppendorf, DE, Germany
| | - S Zeveleva
- Department of Physical Therapy, City University of New York - College of Staten Island, USA
| | - A Duarte
- Department of Physical Therapy, City University of New York - College of Staten Island, USA
| | - X Zhao
- Department of Chemistry, City University of New York - College of Staten Island, USA
| | - B Depalle
- Department of Materials, Imperial College London, UK
| | - L Cardoso
- Department of Biomedical Engineering, City University of New York - City College of New York, USA
| | - S Jin
- Department of Chemistry, City University of New York - College of Staten Island, USA
| | - J P Berteau
- Department of Physical Therapy, City University of New York - College of Staten Island, USA; New York Center for Biomedical Engineering, City University of New York - City College of New York, USA; Nanoscience Initiative, Advanced Science Research Center, City University of New York, USA.
| |
Collapse
|
21
|
Javidi M, McGowan CP, Schiele NR, Lin DC. Tendons from kangaroo rats are exceptionally strong and tough. Sci Rep 2019; 9:8196. [PMID: 31160640 PMCID: PMC6546749 DOI: 10.1038/s41598-019-44671-9] [Citation(s) in RCA: 12] [Impact Index Per Article: 2.4] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/31/2018] [Accepted: 05/17/2019] [Indexed: 11/14/2022] Open
Abstract
Tendons must be able to withstand the forces generated by muscles and not fail. Accordingly, a previous comparative analysis across species has shown that tendon strength (i.e., failure stress) increases for larger species. In addition, the elastic modulus increases proportionally to the strength, demonstrating that the two properties co-vary. However, some species may need specially adapted tendons to support high performance motor activities, such as sprinting and jumping. Our objective was to determine if the tendons of kangaroo rats (k-rat), small bipedal animals that can jump as high as ten times their hip height, are an exception to the linear relationship between elastic modulus and strength. We measured and compared the material properties of tendons from k-rat ankle extensor muscles to those of similarly sized white rats. The elastic moduli of k-rat and rat tendons were not different, but k-rat tendon failure stresses were much larger than the rat values (nearly 2 times larger), as were toughness (over 2.5 times larger) and ultimate strain (over 1.5 times longer). These results support the hypothesis that the tendons from k-rats are specially adapted for high motor performance, and k-rat tendon could be a novel model for improving tissue engineered tendon replacements.
Collapse
Affiliation(s)
- Mehrdad Javidi
- Voiland School of Chemical Engineering and Bioengineering, Washington State University, PO Box 646515, Pullman, WA, 99164, USA
| | - Craig P McGowan
- Department of Biological Sciences, University of Idaho, 875 Perimeter Drive, MS 3051, Moscow, ID, 83844, USA.,WWAMI Medical Education Program, University of Idaho, 875 Perimeter Drive, MS 4207, Moscow, ID, 83844, USA.,Washington Center for Muscle Biology, Washington State University, PO Box 646515, Pullman, WA, 99164, USA
| | - Nathan R Schiele
- Department of Biological Engineering, University of Idaho, 875 Perimeter Dr. MS 0904, Moscow, ID, 83844, USA
| | - David C Lin
- Voiland School of Chemical Engineering and Bioengineering, Washington State University, PO Box 646515, Pullman, WA, 99164, USA. .,Washington Center for Muscle Biology, Washington State University, PO Box 646515, Pullman, WA, 99164, USA. .,Department of Integrative Physiology and Neuroscience, Washington State University, PO Box 647620, Pullman, WA, 99164, USA.
| |
Collapse
|
22
|
Stenroth L, Thelen D, Franz J. Biplanar ultrasound investigation of in vivo Achilles tendon displacement non-uniformity. TRANSLATIONAL SPORTS MEDICINE 2019; 2:73-81. [PMID: 31008448 PMCID: PMC6472705 DOI: 10.1002/tsm2.61] [Citation(s) in RCA: 14] [Impact Index Per Article: 2.8] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/24/2022]
Abstract
The Achilles tendon is a common tendon for the medial and lateral gastrocnemius and soleus muscles. Non-uniform Achilles tendon regional displacements have been observed in vivo which may result from non-uniform muscle loading and intra-tendinous shearing. However, prior observations are limited to the sagittal plane. This study investigated Achilles tendon tissue displacement patterns during isometric plantarflexor contractions in the coronal and sagittal planes. Fourteen subjects (5 female, 9 male, 26±3 yr) performed maximal isometric plantarflexor contractions with the knee in full extension and flexed to 110°. An ultrasound transducer positioned over the free Achilles tendon collected beam formed radio frequency (RF) data at 70 frames/s. Localized tissue displacements were analyzed using a speckle tracking algorithm. We observed non-uniform Achilles tendon tissue displacements in both imaging planes. Knee joint posture had no significant effect on tissue displacement patterns in either imaging plane. The non-uniform Achilles tendon tissue displacements during loading may arise from the anatomical organization of the sub-tendons associated with the three heads of the triceps surae. The biplanar investigation suggests that greatest displacements are localized to tissue likely to belong to soleus sub-tendon. This study adds novel information with possible implications for muscle coordination, function and muscle-tendon injury mechanisms.
Collapse
Affiliation(s)
- Lauri Stenroth
- Department of Applied Physics, University of Eastern Finland, Finland
- Faculty of Sport and Health Sciences, University of Jyvaskyla, Finland
| | - Darryl Thelen
- Department of Mechanical Engineering, University of Wisconsin – Madison, USA
- Department of Biomedical Engineering, University of Wisconsin – Madison, USA
| | - Jason Franz
- Joint Department of Biomedical Engineering, The University of North Carolina at Chapel Hill and North Carolina State University, USA
| |
Collapse
|
23
|
Clark WH, Franz JR. Do triceps surae muscle dynamics govern non-uniform Achilles tendon deformations? PeerJ 2018; 6:e5182. [PMID: 30013844 PMCID: PMC6046199 DOI: 10.7717/peerj.5182] [Citation(s) in RCA: 17] [Impact Index Per Article: 2.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/01/2018] [Accepted: 06/14/2018] [Indexed: 01/03/2023] Open
Abstract
The human Achilles tendon (AT) consists of sub-tendons arising from the gastrocnemius and soleus muscles that exhibit non-uniform tissue displacements thought to facilitate some independent actuation. However, the mechanisms governing non-uniform displacement patterns within the AT, and their relevance to triceps surae muscle contractile dynamics, have remained elusive. We used a dual-probe ultrasound imaging approach to investigate triceps surae muscle dynamics (i.e., medial gastrocnemius-GAS, soleus-SOL) as a determinant of non-uniform tendon tissue displacements in the human AT. We hypothesized that superficial versus deep differences in AT tissue displacements would be accompanied by and correlate with anatomically consistent differences in GAS versus SOL muscle shortening. Nine subjects performed ramped maximum voluntary isometric contractions at each of five ankle joint angles spanning 10° dorsiflexion to 30° plantarflexion. For all conditions, SOL shortened by an average of 78% more than GAS during moment generation. This was accompanied by, on average, 51% more displacement in the deep versus superficial region of the AT. The magnitude of GAS and SOL muscle shortening positively correlated with displacement in their associated sub-tendons within the AT. Moreover, and as hypothesized, superficial versus deep differences in sub-tendon tissue displacements positively correlated with anatomically consistent differences in GAS versus SOL muscle shortening. We present the first in vivo evidence that triceps surae muscle dynamics may precipitate non-uniform displacement patterns in the architecturally complex AT.
Collapse
Affiliation(s)
- William H Clark
- Joint Department of Biomedical Engineering, University of North Carolina at Chapel Hill and North Carolina State University, Chapel Hill, NC, United States of America
| | - Jason R Franz
- Joint Department of Biomedical Engineering, University of North Carolina at Chapel Hill and North Carolina State University, Chapel Hill, NC, United States of America
| |
Collapse
|
24
|
Massey GJ, Balshaw TG, Maden-Wilkinson TM, Folland JP. Tendinous tissue properties after short- and long-term functional overload: Differences between controls, 12 weeks and 4 years of resistance training. Acta Physiol (Oxf) 2018; 222:e13019. [PMID: 29253326 DOI: 10.1111/apha.13019] [Citation(s) in RCA: 10] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/27/2017] [Revised: 10/27/2017] [Accepted: 12/08/2017] [Indexed: 01/20/2023]
Abstract
AIM The potential for tendinous tissues to adapt to functional overload, especially after several years of exposure to heavy-resistance training, is largely unexplored. This study compared the morphological and mechanical characteristics of the patellar tendon and knee extensor tendon-aponeurosis complex between young men exposed to long-term (4 years; n = 16), short-term (12 weeks; n = 15) and no (untrained controls; n = 39) functional overload in the form of heavy-resistance training. METHODS Patellar tendon cross-sectional area, vastus lateralis aponeurosis area and quadriceps femoris volume, plus patellar tendon stiffness and Young's modulus, and tendon-aponeurosis complex stiffness, were quantified with MRI, dynamometry and ultrasonography. RESULTS As expected, long-term trained had greater muscle strength and volume (+58% and +56% vs untrained, both P < .001), as well as a greater aponeurosis area (+17% vs untrained, P < .01), but tendon cross-sectional area (mean and regional) was not different between groups. Only long-term trained had reduced patellar tendon elongation/strain over the whole force/stress range, whilst both short-term and long-term overload groups had similarly greater stiffness/Young's modulus at high force/stress (short-term +25/22%, and long-term +17/23% vs untrained; all P < .05). Tendon-aponeurosis complex stiffness was not different between groups (ANOVA, P = .149). CONCLUSION Despite large differences in muscle strength and size, years of resistance training did not induce tendon hypertrophy. Both short-term and long-term overload demonstrated similar increases in high-force mechanical and material stiffness, but reduced elongation/strain over the whole force/stress range occurred only after years of overload, indicating a force/strain specific time-course to these adaptations.
Collapse
Affiliation(s)
- G. J. Massey
- Arthritis Research UK Centre for Sport, Exercise and Osteoarthritis; Loughborough University; Leicestershire UK
- School of Sport, Exercise, and Health Sciences; Loughborough University; Leicestershire UK
| | - T. G. Balshaw
- Arthritis Research UK Centre for Sport, Exercise and Osteoarthritis; Loughborough University; Leicestershire UK
- School of Sport, Exercise, and Health Sciences; Loughborough University; Leicestershire UK
| | - T. M. Maden-Wilkinson
- School of Sport, Exercise, and Health Sciences; Loughborough University; Leicestershire UK
- Faculty of Health and Wellbeing; Sheffield Hallam University; Sheffield UK
| | - J. P. Folland
- Arthritis Research UK Centre for Sport, Exercise and Osteoarthritis; Loughborough University; Leicestershire UK
- School of Sport, Exercise, and Health Sciences; Loughborough University; Leicestershire UK
| |
Collapse
|
25
|
Abdala V, Ponssa ML, Tulli MJ, Fabre AC, Herrel A. Frog tendon structure and its relationship with locomotor modes. J Morphol 2018; 279:895-903. [PMID: 29570838 DOI: 10.1002/jmor.20819] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/04/2018] [Revised: 02/14/2018] [Accepted: 02/22/2018] [Indexed: 01/01/2023]
Abstract
Tendon collagen fibrils are the basic force-transmitting units of the tendon. Yet, surprisingly little is known about the diversity in tendon anatomy and ultrastructure, and the possible relationships between this diversity and locomotor modes utilized. Our main objectives were to investigate: (a) the ultra-structural anatomy of the tendons in the digits of frogs; (b) the diversity of collagen fibril diameters across frogs with different locomotor modes; (c) the relationship between morphology, as expressed by the morphology of collagen fibrils and tendons, and locomotor modes. To assess the relationship between morphology and the locomotor modes of the sampled taxa we performed a principal component analysis considering body length, fibrillar cross sectional area (CSA) and tendon CSA. A MANOVA showed that differences between species with different locomotor modes were significant with collagen fibril diameter being the discriminating factor. Overall, our data related the greatest collagen fibril diameter to the most demanding locomotor modes, conversely, the smallest collagen fibril CSA and the highest tendon CSA were observed in animals showing a hopping locomotion requiring likely little absorption of landing forces given the short jump distances.
Collapse
Affiliation(s)
- Virginia Abdala
- Instituto de Biodiversidad Neotropical UNT-CONICET, Cátedra de Biología General. Universidad Nacional de Tucumán, Tucumán, Argentina
| | - María Laura Ponssa
- Unidad Ejecutora Lillo, Fundación Miguel Lillo-CONICET, Tucumán, Argentina
| | - María José Tulli
- Unidad Ejecutora Lillo, Fundación Miguel Lillo-CONICET, Tucumán, Argentina
| | - Anne-Claire Fabre
- Département d'Ecologie et de Gestion de la Biodiversité, 55 rue Buffon, Bat Anatomie Comparee, CP 55, Paris Cedex 5, 75005, France
| | - Anthony Herrel
- Département d'Ecologie et de Gestion de la Biodiversité, 55 rue Buffon, Bat Anatomie Comparee, CP 55, Paris Cedex 5, 75005, France
| |
Collapse
|
26
|
Finni T, Bernabei M, Baan GC, Noort W, Tijs C, Maas H. Non-uniform displacement and strain between the soleus and gastrocnemius subtendons of rat Achilles tendon. Scand J Med Sci Sports 2017; 28:1009-1017. [DOI: 10.1111/sms.13001] [Citation(s) in RCA: 29] [Impact Index Per Article: 4.1] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Accepted: 10/25/2017] [Indexed: 12/17/2022]
Affiliation(s)
- T. Finni
- Neuromuscular Research Center; Faculty of Sport and Health Sciences; University of Jyväskylä; Jyväskylä Finland
| | - M. Bernabei
- Department of Human Movement Sciences; Faculty of Behavioural and Movement Sciences; Vrije Universiteit Amsterdam; Amsterdam Movement Sciences; Amsterdam The Netherlands
| | - G. C. Baan
- Department of Human Movement Sciences; Faculty of Behavioural and Movement Sciences; Vrije Universiteit Amsterdam; Amsterdam Movement Sciences; Amsterdam The Netherlands
| | - W. Noort
- Department of Human Movement Sciences; Faculty of Behavioural and Movement Sciences; Vrije Universiteit Amsterdam; Amsterdam Movement Sciences; Amsterdam The Netherlands
| | - C. Tijs
- Department of Organismic and Evolutionary Biology; Harvard University, Concord Field Station; Bedford MA USA
| | - H. Maas
- Department of Human Movement Sciences; Faculty of Behavioural and Movement Sciences; Vrije Universiteit Amsterdam; Amsterdam Movement Sciences; Amsterdam The Netherlands
| |
Collapse
|
27
|
Zhang R, Han D, Luo G, Ling L, Li G, Ji Q, Li J. Macroscopic and microscopic analyses in flexor tendons of the tarsometatarso-phalangeal joint of ostrich (Struthio camelus) foot with energy storage and shock absorption. J Morphol 2017; 279:302-311. [PMID: 29148083 DOI: 10.1002/jmor.20772] [Citation(s) in RCA: 11] [Impact Index Per Article: 1.6] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/18/2017] [Revised: 10/23/2017] [Accepted: 10/27/2017] [Indexed: 12/31/2022]
Abstract
Flexor tendons function as energy storage and shock absorption structures in the tarsometatarso-phalangeal joint (TMTPJ) of ostrich feet during high-speed and heavy-load locomotion. In this study, mechanisms underlying the energy storage and shock absorption of three flexor tendons of the third toe were studied using histology and scanning electron microscopy (SEM). Macroscopic and microscopic structures of the flexor tendons in different positions of TMTPJ were analyzed. Histological slices showed collagen fiber bundles of all flexor tendons in the middle TMTPJ were arranged in a linear-type, but in the proximal and distal TMTPJ, a wavy-type arrangement was found in the tendon of the M. flexor digitorum longus and tendon of the M. flexor perforans et perforatus digiti III, while no regular-type was found in the tendon of the M. flexor perforatus digiti III. SEM showed that the collagen fiber bundles of flexor tendons were arranged in a hierarchically staggered way (horizontally linear-type and vertically linear-type). Linear-type and wavy-type both existed in the proximal TMTPJ for the collagen fiber bundles of the tendon of the M. flexor perforatus digiti III, but only the linear-type was found in the distal TMTPJ. A number of fibrils were distributed among the collagen fiber bundles, which were likely effective in connection, force transmission and other functions. The morphology and arrangement of collagen fiber bundles were closely related to the tendon functions. We present interpretations of the biological functions in different positions and types of the tendons in the TMTPJ of the ostrich feet.
Collapse
Affiliation(s)
- Rui Zhang
- Key Laboratory of Bionic Engineering, Ministry of Education, Jilin University, Changchun, People's Republic of China
| | - Dianlei Han
- Key Laboratory of Bionic Engineering, Ministry of Education, Jilin University, Changchun, People's Republic of China
| | - Gang Luo
- Key Laboratory of Bionic Engineering, Ministry of Education, Jilin University, Changchun, People's Republic of China
| | - Lei Ling
- Key Laboratory of Bionic Engineering, Ministry of Education, Jilin University, Changchun, People's Republic of China
| | - Guoyu Li
- Key Laboratory of Bionic Engineering, Ministry of Education, Jilin University, Changchun, People's Republic of China
| | - Qiaoli Ji
- Key Laboratory of Bionic Engineering, Ministry of Education, Jilin University, Changchun, People's Republic of China
| | - Jianqiao Li
- Key Laboratory of Bionic Engineering, Ministry of Education, Jilin University, Changchun, People's Republic of China
| |
Collapse
|
28
|
Moore TY, Rivera AM, Biewener AA. Vertical leaping mechanics of the Lesser Egyptian Jerboa reveal specialization for maneuverability rather than elastic energy storage. Front Zool 2017; 14:32. [PMID: 28680452 PMCID: PMC5496339 DOI: 10.1186/s12983-017-0215-z] [Citation(s) in RCA: 17] [Impact Index Per Article: 2.4] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/12/2016] [Accepted: 06/05/2017] [Indexed: 11/10/2022] Open
Abstract
BACKGROUND Numerous historical descriptions of the Lesser Egyptian jerboa, Jaculus jaculus, a small bipedal mammal with elongate hindlimbs, make special note of their extraordinary leaping ability. We observed jerboa locomotion in a laboratory setting and performed inverse dynamics analysis to understand how this small rodent generates such impressive leaps. We combined kinematic data from video, kinetic data from a force platform, and morphometric data from dissections to calculate the relative contributions of each hindlimb muscle and tendon to the total movement. RESULTS Jerboas leapt in excess of 10 times their hip height. At the maximum recorded leap height (not the maximum observed leap height), peak moments for metatarso-phalangeal, ankle, knee, and hip joints were 13.1, 58.4, 65.1, and 66.9 Nmm, respectively. Muscles acting at the ankle joint contributed the most work (mean 231.6 mJ / kg Body Mass) to produce the energy of vertical leaping, while muscles acting at the metatarso-phalangeal joint produced the most stress (peak 317.1 kPa). The plantaris, digital flexors, and gastrocnemius tendons encountered peak stresses of 25.6, 19.1, and 6.0 MPa, respectively, transmitting the forces of their corresponding muscles (peak force 3.3, 2.0, and 3.8 N, respectively). Notably, we found that the mean elastic energy recovered in the primary tendons of both hindlimbs comprised on average only 4.4% of the energy of the associated leap. CONCLUSIONS The limited use of tendon elastic energy storage in the jerboa parallels the morphologically similar heteromyid kangaroo rat, Dipodomys spectabilis. When compared to larger saltatory kangaroos and wallabies that sustain hopping over longer periods of time, these small saltatory rodents store and recover less elastic strain energy in their tendons. The large contribution of muscle work, rather than elastic strain energy, to the vertical leap suggests that the fitness benefit of rapid acceleration for predator avoidance dominated over the need to enhance locomotor economy in the evolutionary history of jerboas.
Collapse
Affiliation(s)
- Talia Y Moore
- Concord Field Station, Harvard University, 100 Old Causeway Road, Bedford, MA 01730 USA.,University of Michigan, Museum of Zoology and Department of Ecology and Evolutionary Biology, Ruthven Museum, 1109 Geddes Ave, Ann Arbor, MI 48109 USA
| | - Alberto M Rivera
- Concord Field Station, Harvard University, 100 Old Causeway Road, Bedford, MA 01730 USA
| | - Andrew A Biewener
- Concord Field Station, Harvard University, 100 Old Causeway Road, Bedford, MA 01730 USA
| |
Collapse
|
29
|
Bontempi M. A proposal to evaluate the fibers’ break probability in ligaments and tendons. J Biomech 2017; 57:103-109. [DOI: 10.1016/j.jbiomech.2017.03.022] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/20/2016] [Revised: 02/22/2017] [Accepted: 03/31/2017] [Indexed: 10/19/2022]
|
30
|
Zhang J, Yuan T, Zheng N, Zhou Y, Hogan MV, Wang JHC. The combined use of kartogenin and platelet-rich plasma promotes fibrocartilage formation in the wounded rat Achilles tendon entheses. Bone Joint Res 2017; 6:231-244. [PMID: 28450316 PMCID: PMC5415905 DOI: 10.1302/2046-3758.64.bjr-2017-0268.r1] [Citation(s) in RCA: 34] [Impact Index Per Article: 4.9] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 10/07/2016] [Accepted: 02/10/2017] [Indexed: 01/01/2023] Open
Abstract
Objectives After an injury, the biological reattachment of tendon to bone is a challenge because healing takes place between a soft (tendon) and a hard (bone) tissue. Even after healing, the transition zone in the enthesis is not completely regenerated, making it susceptible to re-injury. In this study, we aimed to regenerate Achilles tendon entheses (ATEs) in wounded rats using a combination of kartogenin (KGN) and platelet-rich plasma (PRP). Methods Wounds created in rat ATEs were given three different treatments: kartogenin platelet-rich plasma (KGN-PRP); PRP; or saline (control), followed by histological and immunochemical analyses, and mechanical testing of the rat ATEs after three months of healing. Results Histological analysis showed well organised arrangement of collagen fibres and proteoglycan formation in the wounded ATEs in the KGN-PRP group. Furthermore, immunohistochemical analysis revealed fibrocartilage formation in the KGN-PRP-treated ATEs, evidenced by the presence of both collagen I and II in the healed ATE. Larger positively stained collagen III areas were found in both PRP and saline groups than those in the KGN-PRP group. Chondrocyte-related genes, SOX9 and collagen II, and tenocyte-related genes, collagen I and scleraxis (SCX), were also upregulated by KGN-PRP. Moreover, mechanical testing results showed higher ultimate tensile strength in the KGN-PRP group than in the saline control group. In contrast, PRP treatment appeared to have healed the injured ATE but induced no apparent formation of fibrocartilage. The saline-treated group showed poor healing without fibrocartilage tissue formation in the ATEs. Conclusions Our results show that injection of KGN-PRP induces fibrocartilage formation in the wounded rat ATEs. Hence, KGN-PRP may be a clinically relevant, biological approach to regenerate injured enthesis effectively. Cite this article: J. Zhang, T. Yuan, N. Zheng, Y. Zhou, M. V. Hogan, J. H-C. Wang. The combined use of kartogenin and platelet-rich plasma promotes fibrocartilage formation in the wounded rat Achilles tendon entheses. Bone Joint Res 2017;6:231–244. DOI: 10.1302/2046-3758.64.BJR-2017-0268.R1.
Collapse
Affiliation(s)
- J Zhang
- Department of Orthopaedic Surgery, University of Pittsburgh School of Medicine, 200 Lothrop Street, Pittsburgh, Pennsylvania 15213, USA
| | - T Yuan
- Department of Orthopaedic Surgery, University of Pittsburgh School of Medicine, 200 Lothrop Street, Pittsburgh, Pennsylvania 15213, USA
| | - N Zheng
- Department of Mechanical Engineering, University of North Carolina, 9201 University City Blvd, Mechanical Engineering, Duke 201, Charlotte, North Carolina, USA
| | - Y Zhou
- Department of Orthopaedic Surgery, University of Pittsburgh School of Medicine, 200 Lothrop Street, Pittsburgh, Pennsylvania 15213, USA
| | - M V Hogan
- Department of Orthopaedic Surgery, University of Pittsburgh School of Medicine, 200 Lothrop Street, Pittsburgh, Pennsylvania 15213, USA
| | - J H-C Wang
- Department of Orthopaedic Surgery, University of Pittsburgh School of Medicine, 200 Lothrop Street, Pittsburgh, Pennsylvania 15213, USA
| |
Collapse
|
31
|
Hessel AL, Nishikawa KC. Effects of a titin mutation on negative work during stretch-shortening cycles in skeletal muscles. J Exp Biol 2017; 220:4177-4185. [DOI: 10.1242/jeb.163204] [Citation(s) in RCA: 14] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/22/2017] [Accepted: 09/15/2017] [Indexed: 01/17/2023]
Abstract
Negative work occurs in muscles during braking movements such as downhill walking or landing after a jump. When performing negative work during stretch-shortening cycles, viscoelastic structures within muscles store energy during stretch, return a fraction of this energy during shortening, and dissipate the remaining energy as heat. Because tendons and extracellular matrix are relatively elastic rather than viscoelastic, energy is mainly dissipated by cross bridges and titin. Recent studies demonstrate that titin stiffness increases in active skeletal muscles, suggesting that titin contributions to negative work may have been underestimated in previous studies. The muscular dystrophy with myositis (mdm) mutation in mice results in a deletion in titin that leads to reduced titin stiffness in active muscle, providing an opportunity to investigate the contribution of titin to negative work in stretch-shortening cycles. Using the work loop technique, extensor digitorum longus and soleus muscles from mdm and wild type mice were stimulated during the stretch phase of stretch-shortening cycles to investigate negative work. The results demonstrate that, compared to wild type muscles, negative work is reduced in muscles from mdm mice. We suggest that changes in the viscoelastic properties of mdm titin reduce energy storage by muscles during stretch and energy dissipation during shortening. Maximum isometric stress is also reduced in muscles from mdm mice, possibly due to impaired transmission of cross bridge force, impaired cross bridge function, or both. Functionally, the reduction in negative work could lead to increased muscle damage during eccentric contractions that occur during braking movements.
Collapse
Affiliation(s)
- Anthony L. Hessel
- Center for Bioengineering Innovation and Department of Biological Sciences, Northern Arizona University, PO Box 4185, Flagstaff, AZ 86011, USA
| | - Kiisa C. Nishikawa
- Center for Bioengineering Innovation and Department of Biological Sciences, Northern Arizona University, PO Box 4185, Flagstaff, AZ 86011, USA
| |
Collapse
|
32
|
Creechley JJ, Krentz ME, Lujan TJ. Fatigue life of bovine meniscus under longitudinal and transverse tensile loading. J Mech Behav Biomed Mater 2016; 69:185-192. [PMID: 28088070 DOI: 10.1016/j.jmbbm.2016.12.020] [Citation(s) in RCA: 9] [Impact Index Per Article: 1.1] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/01/2016] [Revised: 12/19/2016] [Accepted: 12/23/2016] [Indexed: 12/12/2022]
Abstract
The knee meniscus is composed of a fibrous extracellular matrix that is subjected to large and repeated loads. Consequently, the meniscus is frequently torn, and a potential mechanism for failure is fatigue. The objective of this study was to measure the fatigue life of bovine meniscus when applying cyclic tensile loads either longitudinal or transverse to the principal fiber direction. Fatigue experiments consisted of cyclic loads to 60%, 70%, 80% or 90% of the predicted ultimate tensile strength until failure occurred or 20,000 cycles was reached. The fatigue data in each group was fit with a Weibull distribution to generate plots of stress level vs. cycles to failure (S-N curve). Results showed that loading transverse to the principal fiber direction gave a two-fold increase in failure strain, a three-fold increase in creep, and a nearly four-fold increase in cycles to failure (not significant), compared to loading longitudinal to the principal fiber direction. The S-N curves had strong negative correlations between the stress level and the mean cycles to failure for both loading directions, where the slope of the transverse S-N curve was 11% less than the longitudinal S-N curve (longitudinal: S=108-5.9ln(N); transverse: S=112-5.2ln(N)). Collectively, these results suggest that the non-fibrillar matrix is more resistant to fatigue failure than the collagen fibers. Results from this study are relevant to understanding the etiology of atraumatic radial and horizontal meniscal tears, and can be utilized by research groups that are working to develop meniscus implants with fatigue properties that mimic healthy tissue.
Collapse
Affiliation(s)
- Jaremy J Creechley
- Boise State University, 1910 University Drive, Boise, ID 83725-2085, United States.
| | - Madison E Krentz
- Boise State University, 1910 University Drive, Boise, ID 83725-2085, United States.
| | - Trevor J Lujan
- Boise State University, 1910 University Drive, Boise, ID 83725-2085, United States.
| |
Collapse
|
33
|
Roberts TJ. Contribution of elastic tissues to the mechanics and energetics of muscle function during movement. ACTA ACUST UNITED AC 2016; 219:266-75. [PMID: 26792339 DOI: 10.1242/jeb.124446] [Citation(s) in RCA: 118] [Impact Index Per Article: 14.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/26/2023]
Abstract
Muscle force production occurs within an environment of tissues that exhibit spring-like behavior, and this elasticity is a critical determinant of muscle performance during locomotion. Muscle force and power output both depend on the speed of contraction, as described by the isotonic force-velocity curve. By influencing the speed of contractile elements, elastic structures can have a profound effect on muscle force, power and work. In very rapid movements, elastic mechanisms can amplify muscle power by storing the work of muscle contraction slowly and releasing it rapidly. When energy must be dissipated rapidly, such as in landing from a jump, energy stored rapidly in elastic elements can be released more slowly to stretch muscle contractile elements, reducing the power input to muscle and possibly protecting it from damage. Elastic mechanisms identified so far rely primarily on in-series tendons, but many structures within muscles exhibit spring-like properties. Actomyosin cross-bridges, actin and myosin filaments, titin, and the connective tissue scaffolding of the extracellular matrix all have the potential to store and recover elastic energy during muscle contraction. The potential contribution of these elements can be assessed from their stiffness and estimates of the strain they undergo during muscle function. Such calculations provide boundaries for the possible roles these springs might play in locomotion, and may help to direct future studies of the uses of elastic elements in muscle.
Collapse
Affiliation(s)
- Thomas J Roberts
- Department of Ecology and Evolutionary Biology, Brown University, Providence, RI 02912, USA
| |
Collapse
|
34
|
Mechanical and material properties of the plantarflexor muscles and Achilles tendon in children with spastic cerebral palsy and typically developing children. J Biomech 2016; 49:3004-3008. [DOI: 10.1016/j.jbiomech.2016.07.020] [Citation(s) in RCA: 29] [Impact Index Per Article: 3.6] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/06/2015] [Revised: 07/20/2016] [Accepted: 07/20/2016] [Indexed: 11/18/2022]
|
35
|
Konow N, Cheney JA, Roberts TJ, Waldman JRS, Swartz SM. Spring or string: does tendon elastic action influence wing muscle mechanics in bat flight? Proc Biol Sci 2016; 282:20151832. [PMID: 26423848 DOI: 10.1098/rspb.2015.1832] [Citation(s) in RCA: 24] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/24/2023] Open
Abstract
Tendon springs influence locomotor movements in many terrestrial animals, but their roles in locomotion through fluids as well as in small-bodied mammals are less clear. We measured muscle, tendon and joint mechanics in an elbow extensor of a small fruit bat during ascending flight. At the end of downstroke, the tendon was stretched by elbow flexion as the wing was folded. At the end of upstroke, elastic energy was recovered via tendon recoil and extended the elbow, contributing to unfurling the wing for downstroke. Compared with a hypothetical 'string-like' system lacking series elastic compliance, the tendon spring conferred a 22.5% decrease in muscle fascicle strain magnitude. Our findings demonstrate tendon elastic action in a small flying mammal and expand our understanding of the occurrence and action of series elastic actuator mechanisms in fluid-based locomotion.
Collapse
Affiliation(s)
- Nicolai Konow
- Department of Ecology and Evolutionary Biology, Providence, RI 02912, USA
| | - Jorn A Cheney
- Department of Ecology and Evolutionary Biology, Providence, RI 02912, USA
| | - Thomas J Roberts
- Department of Ecology and Evolutionary Biology, Providence, RI 02912, USA
| | - J Rhea S Waldman
- Department of Ecology and Evolutionary Biology, Providence, RI 02912, USA
| | - Sharon M Swartz
- Department of Ecology and Evolutionary Biology, Providence, RI 02912, USA School of Engineering, Brown University, Providence, RI 02912, USA
| |
Collapse
|
36
|
Decellularized and Engineered Tendons as Biological Substitutes: A Critical Review. Stem Cells Int 2016; 2016:7276150. [PMID: 26880985 PMCID: PMC4736572 DOI: 10.1155/2016/7276150] [Citation(s) in RCA: 54] [Impact Index Per Article: 6.8] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/09/2015] [Accepted: 11/10/2015] [Indexed: 12/18/2022] Open
Abstract
Tendon ruptures are a great burden in clinics. Finding a proper graft material as a substitute for tendon repair is one of the main challenges in orthopaedics, for which the requirement of a biological scaffold would be different for each clinical application. Among biological scaffolds, the use of decellularized tendon-derived matrix increasingly represents an interesting approach to treat tendon ruptures. We analyzed in vitro and in vivo studies focused on the development of efficient protocols for the decellularization and for the cell reseeding of the tendon matrix to obtain medical devices for tendon substitution. Our review considered also the proper tendon source and preclinical animal models with the aim of entering into clinical trials. The results highlight a wide panorama in terms of allogenic or xenogeneic tendon sources, specimen dimensions, physical or chemical decellularization techniques, and the cell type variety for reseeding from terminally differentiated to undifferentiated mesenchymal stem cells and their static or dynamic culture employed to generate implantable constructs tested in different animal models. We try to identify the most efficient approach to achieve an optimal biological scaffold for biomechanics and intrinsic properties, resembling the native tendon and being applicable in clinics in the near future, with particular attention to the Achilles tendon substitution.
Collapse
|
37
|
Foster KL, Higham TE. Integrating gastrocnemius force-length properties, in vivo activation, and operating lengths reveals how Anolis deal with ecological challenges. J Exp Biol 2016; 220:796-806. [DOI: 10.1242/jeb.151795] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/17/2016] [Accepted: 12/08/2016] [Indexed: 11/20/2022]
Abstract
A central question in biology is how animals successfully behave under complex natural conditions. Although changes in locomotor behaviour, motor control, and force production in relation to incline are commonly examined, a wide range of other factors, including a range of perch diameters, pervades arboreal habitats. Moving on different substrate diameters requires considerable alteration of body and limb posture, likely causing significant shifts in the lengths of the muscle-tendon units powering locomotion. Thus, how substrate shape impacts in vivo muscle function remains an important, but neglected question in ecophysiology. Here, we used high-speed videography, electromyography, in situ contractile experiments, and morphology to examine gastrocnemius muscle function during arboreal locomotion in the Cuban knight anole, (Anolis equestris). The gastrocnemius contributes more to the propulsive effort on broad surfaces than on narrow surfaces. Surprisingly, substrate inclination affected the relationship between the maximum potential force and fibre recruitment; the trade-off that was present between these variables on horizontal conditions became a positive relationship on inclined surfaces. Finally, the biarticular nature of the gastrocnemius allows it to generate force isometrically, regardless of condition, despite the fact that the tendons are incapable of stretching during cyclical locomotion. Our results emphasize the importance of considering ecology and muscle function together, and the necessity of examining both mechanical and physiological properties of muscles to understand how animals move in their environment.
Collapse
Affiliation(s)
- Kathleen L. Foster
- Department of Biology, University of California, 900 University Avenue, Riverside, CA, 92521, USA
- Current address: Department of Biology, University of Ottawa, 30 Marie Curie, Ottawa, ON, K1N7N1, Canada
| | - Timothy E. Higham
- Department of Biology, University of California, 900 University Avenue, Riverside, CA, 92521, USA
| |
Collapse
|
38
|
Lionello G, Fognani R, Baleani M, Sudanese A, Toni A. Suturing the myotendinous junction in total hip arthroplasty: A biomechanical comparison of different stitching techniques. Clin Biomech (Bristol, Avon) 2015; 30:1077-82. [PMID: 26392227 DOI: 10.1016/j.clinbiomech.2015.09.003] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 03/31/2015] [Revised: 08/31/2015] [Accepted: 09/01/2015] [Indexed: 02/07/2023]
Abstract
BACKGROUND The repair of the myotendinous junction following total hip arthroplasty is challenging as this region is the weakest part of the muscle structure. This study investigated the mechanical behaviour and the mode of failure of different suturing techniques of the myotendinous junction. A new asymmetrical stitch was compared to two widely used techniques, i.e. the simple stitch (two loops in parallel) and the figure-of-eight stitch. METHODS The ovine triceps brachii myotendinous junction was selected as the experimental model. Each technique was sewn in muscle belly on one side and in a polyester belt (no-tendon configuration) or in thin tendon (full configuration) on the other side. The former was chosen to determine the grasping power of the stitch on the muscle despite the tendon quality, the latter to simulate a very thin gluteus medius tendon. FINDINGS The new stitch showed a higher ultimate strength (+40%) compared to the two controls in the no-tendon configuration. In the full configuration, no significant increase was observed, although failure of the new stitch always occurred at the tendon side. Furthermore, the new stitch does not alter the stiffness of repair. INTERPRETATION The new stitch has a higher grasping power on muscle belly than the single passing-through stitches thanks to the multiple fixation points, which better distribute the load in the tissue. However, such performance can be fully exploited only in the presence of good quality tendons.
Collapse
Affiliation(s)
- Giacomo Lionello
- Laboratorio di Tecnologia Medica, Istituto Ortopedico Rizzoli, Bologna, Italy
| | - Roberta Fognani
- Laboratorio Prometeo, Istituto Ortopedico Rizzoli, Bologna, Italy
| | | | - Alessandra Sudanese
- Ortopedia-Traumatologia e Chirurgia protesica e dei reimpianti d'anca e di ginocchio, Istituto Ortopedico Rizzoli, Bologna, Italy
| | - Aldo Toni
- Laboratorio di Tecnologia Medica, Istituto Ortopedico Rizzoli, Bologna, Italy; Ortopedia-Traumatologia e Chirurgia protesica e dei reimpianti d'anca e di ginocchio, Istituto Ortopedico Rizzoli, Bologna, Italy
| |
Collapse
|
39
|
Konow N, Roberts TJ. The series elastic shock absorber: tendon elasticity modulates energy dissipation by muscle during burst deceleration. Proc Biol Sci 2015; 282:20142800. [PMID: 25716796 DOI: 10.1098/rspb.2014.2800] [Citation(s) in RCA: 67] [Impact Index Per Article: 7.4] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/12/2022] Open
Abstract
During downhill running, manoeuvring, negotiation of obstacles and landings from a jump, mechanical energy is dissipated via active lengthening of limb muscles. Tendon compliance provides a 'shock-absorber' mechanism that rapidly absorbs mechanical energy and releases it more slowly as the recoil of the tendon does work to stretch muscle fascicles. By lowering the rate of muscular energy dissipation, tendon compliance likely reduces the risk of muscle injury that can result from rapid and forceful muscle lengthening. Here, we examine how muscle-tendon mechanics are modulated in response to changes in demand for energy dissipation. We measured lateral gastrocnemius (LG) muscle activity, force and fascicle length, as well as leg joint kinematics and ground-reaction force, as turkeys performed drop-landings from three heights (0.5-1.5 m centre-of-mass elevation). Negative work by the LG muscle-tendon unit during landing increased with drop height, mainly owing to greater muscle recruitment and force as drop height increased. Although muscle strain did not increase with landing height, ankle flexion increased owing to increased tendon strain at higher muscle forces. Measurements of the length-tension relationship of the muscle indicated that the muscle reached peak force at shorter and likely safer operating lengths as drop height increased. Our results indicate that tendon compliance is important to the modulation of energy dissipation by active muscle with changes in demand and may provide a mechanism for rapid adjustment of function during deceleration tasks of unpredictable intensity.
Collapse
Affiliation(s)
- Nicolai Konow
- Department of Ecology and Evolutionary Biology, Brown University, Box G-B204, Providence, RI 02912, USA
| | - Thomas J Roberts
- Department of Ecology and Evolutionary Biology, Brown University, Box G-B204, Providence, RI 02912, USA
| |
Collapse
|
40
|
Gatt R, Vella Wood M, Gatt A, Zarb F, Formosa C, Azzopardi KM, Casha A, Agius TP, Schembri-Wismayer P, Attard L, Chockalingam N, Grima JN. Negative Poisson's ratios in tendons: An unexpected mechanical response. Acta Biomater 2015; 24:201-8. [PMID: 26102335 DOI: 10.1016/j.actbio.2015.06.018] [Citation(s) in RCA: 44] [Impact Index Per Article: 4.9] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/11/2015] [Revised: 06/11/2015] [Accepted: 06/16/2015] [Indexed: 11/28/2022]
Abstract
Tendons are visco-elastic structures that connect bones to muscles and perform the basic function of force transfer to and from the skeleton. They are essential for positioning as well as energy storing when involved in more abrupt movements such as jumping. Unfortunately, they are also prone to damage, and when injuries occur, they may have dilapidating consequences. For instance, there is consensus that injuries of tendons such as Achilles tendinopathies, which are common in athletes, are difficult to treat. Here we show, through in vivo and ex vivo tests, that healthy tendons are highly anisotropic and behave in a very unconventional manner when stretched, and exhibit a negative Poisson's ratio (auxeticity) in some planes when stretched up to 2% along their length, i.e. within their normal range of motion. Furthermore, since the Poisson's ratio is highly dependent on the material's microstructure, which may be lost if tendons are damaged or diseased, this property may provide a suitable diagnostic tool to assess tendon health. STATEMENT OF SIGNIFICANCE We report that human tendons including the Achilles tendons exhibits the very unusual mechanical property of a negative Poisson's ratio (auxetic) meaning that they get fatter rather than thinner when stretched. This report is backed by in vivo and ex vivo experiments we performed which clearly confirm auxeticity in this living material for strains which correspond to those experienced during most normal everyday activities. We also show that this property is not limited to the human Achilles tendon, as it was also found in tendons taken from sheep and pigs. This new information about tendons can form the scientific basis for a test for tendon health as well as enable the design of better tendon prosthesis which could replace damaged tendons.
Collapse
Affiliation(s)
- Ruben Gatt
- Metamaterials Unit, Faculty of Science, University of Malta, Msida MSD 2080, Malta.
| | - Michelle Vella Wood
- Metamaterials Unit, Faculty of Science, University of Malta, Msida MSD 2080, Malta
| | - Alfred Gatt
- Department of Podiatry, Faculty of Health Sciences, University of Malta, Msida MSD 2080, Malta; Faculty of Health Sciences, Staffordshire University, Science Centre, Leek Road ST4 2DF, UK
| | - Francis Zarb
- Department of Radiography, Faculty of Health Sciences, University of Malta, Msida MSD 2080, Malta
| | - Cynthia Formosa
- Department of Podiatry, Faculty of Health Sciences, University of Malta, Msida MSD 2080, Malta; Faculty of Health Sciences, Staffordshire University, Science Centre, Leek Road ST4 2DF, UK
| | - Keith M Azzopardi
- Metamaterials Unit, Faculty of Science, University of Malta, Msida MSD 2080, Malta
| | - Aaron Casha
- Department of Anatomy, Faculty of Medicine & Surgery, University of Malta, Msida MSD 2080, Malta
| | - Tonio P Agius
- Department of Physiotherapy, Faculty of Health Sciences, University of Malta, Msida MSD 2080, Malta
| | - Pierre Schembri-Wismayer
- Department of Anatomy, Faculty of Medicine & Surgery, University of Malta, Msida MSD 2080, Malta
| | - Lucienne Attard
- Department of Orthopaedics, MaterDei Hospital, Msida MSD 2090, Malta
| | - Nachiappan Chockalingam
- Faculty of Health Sciences, Staffordshire University, Science Centre, Leek Road ST4 2DF, UK; Department of Podiatry, Faculty of Health Sciences, University of Malta, Msida MSD 2080, Malta
| | - Joseph N Grima
- Metamaterials Unit, Faculty of Science, University of Malta, Msida MSD 2080, Malta; Department of Chemistry, Faculty of Science, University of Malta, Msida MSD 2080, Malta
| |
Collapse
|
41
|
Franz JR, Slane LC, Rasske K, Thelen DG. Non-uniform in vivo deformations of the human Achilles tendon during walking. Gait Posture 2015; 41:192-7. [PMID: 25457482 PMCID: PMC4268127 DOI: 10.1016/j.gaitpost.2014.10.001] [Citation(s) in RCA: 85] [Impact Index Per Article: 9.4] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 04/18/2014] [Revised: 08/12/2014] [Accepted: 10/03/2014] [Indexed: 02/02/2023]
Abstract
The free Achilles tendon (AT) consists of distinct fascicles arising from each of the triceps surae muscles that may give rise to non-uniform behavior during functional tasks such as walking. Here, we estimated in vivo deformations of the human AT during walking using simultaneous ultrasound and motion capture measurements. Ten subjects walked at three speeds (0.75, 1.00, and 1.25 m/s) on a force-measuring treadmill. A custom orthotic secured a linear array transducer in two locations: (1) the distal lateral gastrocnemius muscle-tendon junction and (2) the free AT, on average centered 6 cm superior to calcaneal insertion. We used motion capture to record lower extremity kinematics and the position and orientation of the ultrasound transducer. A 2D ultrasound elastography algorithm tracked superficial and deep tissue displacements within the free AT. We estimated AT elongation (i.e., change in length) relative to the calcaneal insertion by transforming the orthotic, transducer, and calcaneus kinematics into a common reference frame. Superficial and deep regions of the free AT underwent significantly different longitudinal displacements and elongations during walking. For example, we found that the superficial AT exhibited 16-29% greater peak elongation than the deep AT during the stance phase of walking (p < 0.01). Moreover, superficial-deep AT tissue deformations became less uniform with faster walking speed (p < 0.01). Non-uniform deformations of the free AT, which could reflect inter-fascicle sliding, may enable the gastrocnemius and soleus muscles to transmit their forces independently while allowing unique kinematic behavior at the muscle fiber level.
Collapse
Affiliation(s)
- Jason R. Franz
- Dept. of Mechanical Engineering, University of Wisconsin-Madison, Madison, WI
| | - Laura C. Slane
- Dept. of Biomedical Engineering, University of Wisconsin-Madison, Madison, WI
| | - Kristen Rasske
- Dept. of Biomedical Engineering, University of Wisconsin-Madison, Madison, WI
| | - Darryl G. Thelen
- Dept. of Mechanical Engineering, University of Wisconsin-Madison, Madison, WI,Dept. of Biomedical Engineering, University of Wisconsin-Madison, Madison, WI,Dept. of Orthopedics and Rehabilitation, University of Wisconsin-Madison, Madison, WI
| |
Collapse
|
42
|
Vereecke EE, Channon AJ. The role of hind limb tendons in gibbon locomotion: springs or strings? ACTA ACUST UNITED AC 2013; 216:3971-80. [PMID: 23868842 DOI: 10.1242/jeb.083527] [Citation(s) in RCA: 14] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/08/2023]
Abstract
Tendon properties have an important effect on the mechanical behaviour of muscles, with compliant tendons allowing near-isometric muscle contraction and facilitating elastic energy storage and recoil. Stiff tendons, in contrast, facilitate rapid force transfer and precise positional control. In humans, the long Achilles tendon contributes to the mechanical efficiency of running via elastic energy storage and recovery, and its presence has been linked to the evolution of habitual bipedalism. Gibbons also possess relatively long hind limb tendons; however, their role is as yet unknown. Based on their large dimensions, and inferring from the situation in humans, we hypothesize that the tendons in the gibbon hind limb will facilitate elastic energy storage and recoil during hind-limb-powered locomotion. To investigate this, we determined the material properties of the gibbon Achilles and patellar tendon in vitro and linked this with available kinematic and kinetic data to evaluate their role in leaping and bipedalism. Tensile tests were conducted on tendon samples using a material testing machine and the load-displacement data were used to calculate stiffness, Young's modulus and hysteresis. In addition, the average stress-in-life and energy absorption capacity of both tendons were estimated. We found a functional difference between the gibbon Achilles and patellar tendon, with the Achilles tendon being more suitable for elastic energy storage and release. The patellar tendon, in contrast, has a relatively high hysteresis, making it less suitable to act as elastic spring. This suggests that the gibbon Achilles tendon might fulfil a similar function as in humans, contributing to reducing the locomotor cost of bipedalism by acting as elastic spring, while the high stiffness of the patellar tendon might favour fast force transfer upon recoil and, possibly, enhance leaping performance.
Collapse
Affiliation(s)
- Evie E Vereecke
- Department of Development and Regeneration @ Kulak, KU Leuven, 3000 Leuven, Belgium
| | | |
Collapse
|