For: Bell J, Tipper JL, Ingham E, Stone MH, Fisher J. The influence of phospholipid concentration in protein-containing lubricants on the wear of ultra-high molecular weight polyethylene in artificial hip joints. Proc Inst Mech Eng H 2001;215:259-63. [PMID: 11382086 DOI: 10.1243/0954411011533661] [Citation(s) in RCA: 39] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [What about the content of this article? (0)] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/28/2022]
Number Cited by Other Article(s)
1
Competitive Binding of Bilirubin and Fatty Acid on Serum Albumin Affects Wear of UHMWPE. LUBRICANTS 2020;8. [PMID: 32655922 PMCID: PMC7351145 DOI: 10.3390/lubricants8050053] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Indexed: 11/16/2022]
2
Duan Y, Liu Y, Zhang C, Chen Z, Wen S. Insight into the Tribological Behavior of Liposomes in Artificial Joints. LANGMUIR : THE ACS JOURNAL OF SURFACES AND COLLOIDS 2016;32:10957-10966. [PMID: 27687876 DOI: 10.1021/acs.langmuir.6b02822] [Citation(s) in RCA: 12] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/06/2023]
3
Silicon Nitride Bearings for Total Joint Arthroplasty. LUBRICANTS 2016. [DOI: 10.3390/lubricants4040035] [Citation(s) in RCA: 11] [Impact Index Per Article: 1.4] [Reference Citation Analysis] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 11/16/2022]
4
Role of hyaluronic acid and phospholipid in the lubrication of a cobalt-chromium head for total hip arthroplasty. Biointerphases 2015;9:031007. [PMID: 25280848 DOI: 10.1116/1.4886255] [Citation(s) in RCA: 24] [Impact Index Per Article: 2.7] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/17/2022]  Open
5
Fröhlich SM, Archodoulaki VM, Allmaier G, Marchetti-Deschmann M. MALDI-TOF Mass Spectrometry Imaging Reveals Molecular Level Changes in Ultrahigh Molecular Weight Polyethylene Joint Implants in Correlation with Lipid Adsorption. Anal Chem 2014;86:9723-32. [DOI: 10.1021/ac5025232] [Citation(s) in RCA: 12] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/28/2022]
6
Jennings LM, Al-Hajjar M, Brockett CL, Williams S, Tipper JL, Ingham E, Fisher J. (iv) Enhancing the safety and reliability of joint replacement implants. ACTA ACUST UNITED AC 2012;26:246-252. [PMID: 23335949 PMCID: PMC3546063 DOI: 10.1016/j.mporth.2012.05.006] [Citation(s) in RCA: 19] [Impact Index Per Article: 1.6] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/13/2022]
7
Lubrication of metal-on-metal hip joints: The effect of protein content and load on film formation and wear. J Mech Behav Biomed Mater 2012;6:30-40. [DOI: 10.1016/j.jmbbm.2011.09.008] [Citation(s) in RCA: 96] [Impact Index Per Article: 8.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/24/2011] [Revised: 09/12/2011] [Accepted: 09/14/2011] [Indexed: 11/20/2022]
8
Fisher J. A stratified approach to pre-clinical tribological evaluation of joint replacements representing a wider range of clinical conditions advancing beyond the current standard. Faraday Discuss 2012;156:59-68; discussion 87-103. [DOI: 10.1039/c2fd00001f] [Citation(s) in RCA: 21] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/13/2022]
9
Harsha AP, Joyce TJ. Challenges associated with using bovine serum in wear testing orthopaedic biopolymers. Proc Inst Mech Eng H 2011;225:948-58. [DOI: 10.1177/0954411911416047] [Citation(s) in RCA: 35] [Impact Index Per Article: 2.7] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/17/2022]
10
Bruck AL, Kanaga Karuppiah KS, Sundararajan S, Wang J, Lin Z. Friction and wear behavior of ultrahigh molecular weight polyethylene as a function of crystallinity in the presence of the phospholipid dipalmitoyl phosphatidylcholine. J Biomed Mater Res B Appl Biomater 2010;93:351-8. [DOI: 10.1002/jbm.b.31587] [Citation(s) in RCA: 19] [Impact Index Per Article: 1.4] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/09/2022]
11
Oral E, Muratoglu OK. Radiation cross-linking in ultra-high molecular weight polyethylene for orthopaedic applications. NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH. SECTION B, BEAM INTERACTIONS WITH MATERIALS AND ATOMS 2007;265:18-22. [PMID: 19050735 PMCID: PMC2151736 DOI: 10.1016/j.nimb.2007.08.022] [Citation(s) in RCA: 37] [Impact Index Per Article: 2.2] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/27/2023]
12
The 2007 Otto Aufranc Award. Ceramic-on-metal hip arthroplasties: a comparative in vitro and in vivo study. Clin Orthop Relat Res 2007;465:23-32. [PMID: 18090468 DOI: 10.1097/blo.0b013e31814da946] [Citation(s) in RCA: 53] [Impact Index Per Article: 3.1] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 01/31/2023]
13
Taddei P, Affatato S, Fagnano C, Toni A. Oxidation in ultrahigh molecular weight polyethylene and cross-linked polyethylene acetabular cups tested against roughened femoral heads in a hip joint simulator. Biomacromolecules 2006;7:1912-20. [PMID: 16768414 DOI: 10.1021/bm060007u] [Citation(s) in RCA: 37] [Impact Index Per Article: 2.1] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/29/2022]
14
Bell CJ, Ingham E, Fisher J. Influence of hyaluronic acid on the time-dependent friction response of articular cartilage under different conditions. Proc Inst Mech Eng H 2006;220:23-31. [PMID: 16459443 DOI: 10.1243/095441105x69060] [Citation(s) in RCA: 73] [Impact Index Per Article: 4.1] [Reference Citation Analysis] [Abstract] [MESH Headings] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/25/2022]
15
Williams S, Jalali-Vahid D, Brockett C, Jin Z, Stone MH, Ingham E, Fisher J. Effect of swing phase load on metal-on-metal hip lubrication, friction and wear. J Biomech 2006;39:2274-81. [PMID: 16143337 DOI: 10.1016/j.jbiomech.2005.07.011] [Citation(s) in RCA: 56] [Impact Index Per Article: 3.1] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/11/2004] [Accepted: 07/17/2005] [Indexed: 12/28/2022]
16
The influences of lipid and protein concentration on wear of ultra-high molecular weight polyethylene. ACTA ACUST UNITED AC 2005. [DOI: 10.1016/s0167-8922(05)80019-7] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register]
17
Mazzucco D, Spector M. The John Charnley Award Paper. The role of joint fluid in the tribology of total joint arthroplasty. Clin Orthop Relat Res 2004:17-32. [PMID: 15577461 DOI: 10.1097/01.blo.0000150315.47697.b9] [Citation(s) in RCA: 47] [Impact Index Per Article: 2.4] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 01/31/2023]
18
Williams S, Stewart TD, Ingham E, Stone MH, Fisher J. Metal-on-metal bearing wear with different swing phase loads. ACTA ACUST UNITED AC 2004;70:233-9. [PMID: 15264305 DOI: 10.1002/jbm.b.30052] [Citation(s) in RCA: 48] [Impact Index Per Article: 2.4] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/28/2022]
19
Hills BA, Crawford RW. Normal and prosthetic synovial joints are lubricated by surface-active phospholipid: a hypothesis. J Arthroplasty 2003;18:499-505. [PMID: 12820095 DOI: 10.1016/s0883-5403(03)00072-x] [Citation(s) in RCA: 76] [Impact Index Per Article: 3.6] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 02/01/2023]  Open
20
Fluid film lubrication in artificial hip joints. ACTA ACUST UNITED AC 2003. [DOI: 10.1016/s0167-8922(03)80136-0] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register]