• Reference Citation Analysis
  • v
  • v
  • Find an Article
Find an Article PDF (4618911)   Today's Articles (2438)   Subscriber (49402)
For: DesJardins J, Aurora A, Tanner SL, Pace TB, Acampora KB, Laberge M. Increased Total Knee Arthroplasty Ultra-High Molecular Weight Polyethylene Wear Using a Clinically Relevant Hyaluronic Acid Simulator Lubricant. Proc Inst Mech Eng H 2006;220:609-23. [PMID: 16898218 DOI: 10.1243/09544119jeim30] [Citation(s) in RCA: 34] [Impact Index Per Article: 1.9] [Reference Citation Analysis] [What about the content of this article? (0)] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/18/2022]
Number Cited by Other Article(s)
1
Radice S, Tibbits G, Lin AYW, Beyenal H, Wimmer MA. Interactions between hyaluronic acid and CoCrMo alloy surface in simulated synovial fluids. BIOSURFACE AND BIOTRIBOLOGY 2021. [DOI: 10.1049/bsb2.12027] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/19/2022]  Open
2
Synthesis of a Lubricant to Mimic the Biorheological Behavior of Osteoarthritic and Revision Synovial Fluid. LUBRICANTS 2021. [DOI: 10.3390/lubricants9090087] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 11/16/2022]
3
Radice S, Impergre A, Fischer A, Wimmer MA. Corrosion resistance of the nickel-free high-nitrogen steel FeCrMnMoN0.9 under simulated inflammatory conditions. J Biomed Mater Res B Appl Biomater 2020;109:902-910. [PMID: 33159504 DOI: 10.1002/jbm.b.34754] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/21/2020] [Revised: 09/03/2020] [Accepted: 10/21/2020] [Indexed: 11/09/2022]
4
Griffiths MW, Athwal GS, Medley JB, Johnson JA, Langohr GDG. Wear of humeral polyethylene cups in reverse total shoulder arthroplasty with simulated rim damage from scapular notching. ACTA ACUST UNITED AC 2020. [DOI: 10.1016/j.biotri.2020.100123] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/26/2023]
5
Effects of bovine serum albumin and hyaluronic acid on the electrochemical response of a CoCrMo alloy to cathodic and anodic excursions. ACTA ACUST UNITED AC 2019;5. [PMID: 31828005 DOI: 10.1007/s40735-019-0299-4] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/25/2022]
6
Radice S, Yao J, Babauta J, Laurent MP, Wimmer MA. The effect of hyaluronic acid on the corrosion of an orthopedic CoCrMo-alloy in simulated inflammatory conditions. MATERIALIA 2019;6:100348. [PMID: 31183460 PMCID: PMC6554727 DOI: 10.1016/j.mtla.2019.100348] [Citation(s) in RCA: 7] [Impact Index Per Article: 1.4] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/09/2023]
7
Abdelgaied A, Fisher J, Jennings LM. A comparison between electromechanical and pneumatic-controlled knee simulators for the investigation of wear of total knee replacements. Proc Inst Mech Eng H 2017;231:643-651. [PMID: 28661228 PMCID: PMC5495426 DOI: 10.1177/0954411917696519] [Citation(s) in RCA: 10] [Impact Index Per Article: 1.4] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/15/2022]
8
Role of hyaluronic acid and phospholipid in the lubrication of a cobalt-chromium head for total hip arthroplasty. Biointerphases 2015;9:031007. [PMID: 25280848 DOI: 10.1116/1.4886255] [Citation(s) in RCA: 24] [Impact Index Per Article: 2.7] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/17/2022]  Open
9
Wear testing of crosslinked polyethylene: wear rate variability and microbial contamination. J Mech Behav Biomed Mater 2014;34:208-16. [PMID: 24607759 DOI: 10.1016/j.jmbbm.2014.02.016] [Citation(s) in RCA: 8] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/07/2013] [Revised: 02/10/2014] [Accepted: 02/11/2014] [Indexed: 11/21/2022]
10
Guenther LE, Pyle BW, Turgeon TR, Bohm ER, Wyss UP, Schmidt TA, Brandt JM. Biochemical analyses of human osteoarthritic and periprosthetic synovial fluid. Proc Inst Mech Eng H 2014;228:127-39. [DOI: 10.1177/0954411913517880] [Citation(s) in RCA: 19] [Impact Index Per Article: 1.9] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/17/2022]
11
Development of a synovial fluid analogue with bio-relevant rheology for wear testing of orthopaedic implants. J Mech Behav Biomed Mater 2013;32:177-184. [PMID: 24469228 DOI: 10.1016/j.jmbbm.2013.12.009] [Citation(s) in RCA: 22] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/15/2013] [Revised: 12/06/2013] [Accepted: 12/08/2013] [Indexed: 11/23/2022]
12
Scholes SC, Joyce TJ. In vitro tests of substitute lubricants for wear testing orthopaedic biomaterials. Proc Inst Mech Eng H 2013;227:693-703. [PMID: 23636752 DOI: 10.1177/0954411913481549] [Citation(s) in RCA: 11] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/16/2022]
13
Brandt JM, Charron K, Zhao L, MacDonald SJ, Medley JB. Calf serum constituent fractions influence polyethylene wear and microbial growth in knee simulator testing. Proc Inst Mech Eng H 2012;226:427-40. [DOI: 10.1177/0954411912444248] [Citation(s) in RCA: 27] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/31/2023]
14
Harsha AP, Joyce TJ. Challenges associated with using bovine serum in wear testing orthopaedic biopolymers. Proc Inst Mech Eng H 2011;225:948-58. [DOI: 10.1177/0954411911416047] [Citation(s) in RCA: 35] [Impact Index Per Article: 2.7] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/17/2022]
15
Kong CG, In Y, Cho HM, Suhl KH. The effects of applying adhesion prevention gel on the range of motion and pain after TKA. Knee 2011;18:104-7. [PMID: 20060726 DOI: 10.1016/j.knee.2009.12.007] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 05/20/2009] [Revised: 12/02/2009] [Accepted: 12/17/2009] [Indexed: 02/02/2023]
16
Brandt JM, Brière LK, Marr J, MacDonald SJ, Bourne RB, Medley JB. Biochemical comparisons of osteoarthritic human synovial fluid with calf sera used in knee simulator wear testing. J Biomed Mater Res A 2010;94:961-71. [PMID: 20730933 DOI: 10.1002/jbm.a.32728] [Citation(s) in RCA: 8] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/10/2022]
17
Maskiewicz VK, Williams PA, Prates SJ, Bowsher JG, Clarke IC. Characterization of protein degradation in serum-based lubricants during simulation wear testing of metal-on-metal hip prostheses. J Biomed Mater Res B Appl Biomater 2010;94:429-440. [PMID: 20583304 DOI: 10.1002/jbm.b.31671] [Citation(s) in RCA: 11] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/07/2022]
18
Bruck AL, Kanaga Karuppiah KS, Sundararajan S, Wang J, Lin Z. Friction and wear behavior of ultrahigh molecular weight polyethylene as a function of crystallinity in the presence of the phospholipid dipalmitoyl phosphatidylcholine. J Biomed Mater Res B Appl Biomater 2010;93:351-8. [DOI: 10.1002/jbm.b.31587] [Citation(s) in RCA: 19] [Impact Index Per Article: 1.4] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/09/2022]
PrevPage 1 of 1 1Next
© 2004-2024 Baishideng Publishing Group Inc. All rights reserved. 7041 Koll Center Parkway, Suite 160, Pleasanton, CA 94566, USA