McLean D, Delfino O, Vozzo M, Moorin R. Estimation of maternal and foetal risk of radiation-induced cancer from a survey of computed tomography pulmonary angiography and ventilation/perfusion lung scanning for diagnosing pulmonary embolism during pregnancy. J Med Imaging Radiat Oncol 2024; 68:385-392. [PMID: 38687690 DOI: 10.1111/1754-9485.13661] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/20/2023] [Accepted: 04/05/2024] [Indexed: 05/02/2024]
Abstract
INTRODUCTION While there are many papers on maternal and foetal radiation doses from computed tomography pulmonary angiography (CTPA) and ventilation/perfusion (V/Q) lung scanning examinations for diagnosing pulmonary embolism in pregnant patients, few have used clinical data to examine the patient lifetime attributable risk (LAR) of different cancer types. This paper aims to estimate the cancer risk from maternal radiation doses from CTPA and V/Q examinations and associated foetal doses. METHODS Dosimetric data were determined for 267 pregnant patients who received CTPA and/or V/Q examinations over 8 years. Organ and foetal doses were determined using software allowing patient size variations for CTPA and using two different activity-to-organ dose conversion methods for V/Q scans. The LAR of cancer incidence was estimated using International Commission on Radiological Protection (ICRP) modelling including estimates of detriment. RESULTS Estimated total cancer incidence was 23 and 22 cases per 100,000 for CTPA and V/Q examinations, respectively, with detriment estimates of 18 and 20 cases. Cancer incidence was evenly divided between lung and breast cancer for CTPA with lung cancer being 80% of all cancer for V/Q. The median foetal doses were 0.03 mSv for CTPA and 0.29 mSv for V/Q. Significant differences in estimated foetal dose for V/Q scans were obtained by the two different methods used. The differences in dose between the modes of CTPA scan acquisition highlight the importance of optimisation. CONCLUSION Maternal cancer incidence and detriment were remarkably similar for each examination. Optimisation of examinations is critical for low-dose outcomes, particularly for CTPA examination.
Collapse
Affiliation(s)
- Donald McLean
- Medical Physics and Radiation Engineering, Canberra Health Services, Canberra, Australian Capital Territory, Australia
| | - Olivia Delfino
- Medical Physics and Radiation Engineering, Canberra Health Services, Canberra, Australian Capital Territory, Australia
| | - Marie Vozzo
- Medical Physics and Radiation Engineering, Canberra Health Services, Canberra, Australian Capital Territory, Australia
| | - Rachael Moorin
- Discipline of Health Economics & Data Analytics, Curtin School of Population Health, Faculty of Health Sciences, Curtin University, Perth, Western Australia, Australia
- School of Population and Global Health, The University of Western Australia, Perth, Western Australia, Australia
| |
Collapse
|
2
|
Schönfeld T, Seitz P, Krieghoff C, Ponorac S, Wötzel A, Olthoff S, Schaudt S, Steglich J, Gutberlet M, Gohmann RF. High-pitch CT pulmonary angiography (CTPA) with ultra-low contrast medium volume for the detection of pulmonary embolism: a comparison with standard CTPA. Eur Radiol 2024; 34:1921-1931. [PMID: 37656178 PMCID: PMC10873234 DOI: 10.1007/s00330-023-10101-8] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/29/2022] [Revised: 06/29/2023] [Accepted: 07/05/2023] [Indexed: 09/02/2023]
Abstract
OBJECTIVE To investigate the feasibility and image quality of high-pitch CT pulmonary angiography (CTPA) with reduced iodine volume in normal weight patients. METHODS In total, 81 normal weight patients undergoing CTPA for suspected pulmonary arterial embolism were retrospectively included: 41 in high-pitch mode with 20 mL of contrast medium (CM); and 40 with normal pitch and 50 mL of CM. Subjective image quality was assessed and rated on a 3-point scale. For objective image quality, attenuation and noise values were measured in all pulmonary arteries from the trunk to segmental level. Contrast-to-noise ratio (CNR) was calculated. Radiation dose estimations were recorded. RESULTS There were no statistically significant differences in patient and scan demographics between high-pitch and standard CTPA. Subjective image quality was rated good to excellent in over 90% of all exams with no significant group differences (p = 0.32). Median contrast opacification was lower in high-pitch CTPA (283.18 [216.06-368.67] HU, 386.81 [320.57-526.12] HU; p = 0.0001). CNR reached a minimum of eight in all segmented arteries, but was lower in high-pitch CTPA (8.79 [5.82-12.42], 11.01 [9.19-17.90]; p = 0.005). Median effective dose of high-pitch CTPA was lower (1.04 [0.72-1.27] mSv/mGy·cm; 1.49 [1.07-2.05] mSv/mGy·cm; p < 0.0001). CONCLUSION High-pitch CTPA using ultra-low contrast volume (20 mL) rendered diagnostic images for the detection of pulmonary arterial embolism in most instances. Compared to standard CTPA, the high-pitch CTPA exams with drastically reduced contrast medium volume had also concomitantly reduced radiation exposure. However, objective image quality of high-pitch CTPA was worse, though likely still within acceptable limits for confident diagnosis. CLINICAL RELEVANCE This study provides valuable insights on the performance of a high-pitch dual-source CTPA protocol, offering potential benefits in reducing contrast medium and radiation dose while maintaining sufficient image quality for accurate diagnosis in patients suspected of pulmonary embolism. KEY POINTS • High-pitch CT pulmonary angiography (CTPA) with ultra-low volume of contrast medium and reduced radiation dose renders diagnostic examinations with comparable subjective image quality to standard CTPA in most patients. • Objective image quality of high-pitch CTPA is reduced compared to standard CTPA, but contrast opacification and contrast-to-noise ratio remain above diagnostic thresholds. • Challenges of high-pitch CTPA may potentially be encountered in patients with severe heart failure or when performing a Valsalva maneuver during the examination.
Collapse
Affiliation(s)
- Tobias Schönfeld
- Department of Diagnostic and Interventional Radiology, Heart Center Leipzig, Strümpellstr. 39, 04289, Leipzig, Germany
- Department of General and Geriatric Medicine, St. Elisabeth-Hospital Leipzig, Biedermannstr. 84, 04277, Leipzig, Germany
- Medical Faculty, University of Leipzig, Liebigstr. 27, 04103, Leipzig, Germany
| | - Patrick Seitz
- Department of Diagnostic and Interventional Radiology, Heart Center Leipzig, Strümpellstr. 39, 04289, Leipzig, Germany
| | - Christian Krieghoff
- Department of Diagnostic and Interventional Radiology, Heart Center Leipzig, Strümpellstr. 39, 04289, Leipzig, Germany
| | - Slavica Ponorac
- Department of Diagnostic and Interventional Radiology, Heart Center Leipzig, Strümpellstr. 39, 04289, Leipzig, Germany
- Institute of Radiology, University Medical Centre Ljubljana, Zaloška Cesta 7, 1000, Ljubljana, Slovenia
| | - Alexander Wötzel
- Emergency Department, Helios Park-Clinic Leipzig, Strümpellstr. 41, 04289, Leipzig, Germany
| | - Stefan Olthoff
- Department of Diagnostic and Interventional Radiology, Heart Center Leipzig, Strümpellstr. 39, 04289, Leipzig, Germany
| | - Sebastian Schaudt
- Department of Diagnostic and Interventional Radiology, Heart Center Leipzig, Strümpellstr. 39, 04289, Leipzig, Germany
- Medical Faculty, University of Leipzig, Liebigstr. 27, 04103, Leipzig, Germany
| | - Jonas Steglich
- Department of Diagnostic and Interventional Radiology, Heart Center Leipzig, Strümpellstr. 39, 04289, Leipzig, Germany
| | - Matthias Gutberlet
- Department of Diagnostic and Interventional Radiology, Heart Center Leipzig, Strümpellstr. 39, 04289, Leipzig, Germany
- Medical Faculty, University of Leipzig, Liebigstr. 27, 04103, Leipzig, Germany
- Leipzig Heart Institute, Russenstr. 69a, 04289, Leipzig, Germany
| | - Robin F Gohmann
- Department of Diagnostic and Interventional Radiology, Heart Center Leipzig, Strümpellstr. 39, 04289, Leipzig, Germany.
- Medical Faculty, University of Leipzig, Liebigstr. 27, 04103, Leipzig, Germany.
| |
Collapse
|
3
|
Hassan A, Taleb M, Hasan W, Shehab F, Maki R, Alhamar N. Positive rate and quality assessment of CT pulmonary angiography in sickle cell disease: a case‒control study. Emerg Radiol 2023; 30:209-216. [PMID: 36947347 PMCID: PMC10031195 DOI: 10.1007/s10140-023-02126-9] [Citation(s) in RCA: 1] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/23/2022] [Accepted: 03/14/2023] [Indexed: 03/23/2023]
Abstract
BACKGROUND Pulmonary complications are common in sickle cell disease (SCD) and can mimic pulmonary embolisms (PEs), leading to potential overuse of computed tomography pulmonary angiography (CTPA). Maximizing the quality of CTPA is essential for its diagnostic accuracy. However, little is known about the positive rate and quality of CTPA in SCD. METHODS This retrospective case‒control study aimed to determine the positive rate and quality of CTPA studies performed to rule out PE in SCD (HbSS genotype) patients compared to a control group. Logistic regression analysis was used to identify independent factors associated with suboptimal CTPA studies, defined as a mean enhancement of < 210 HU in the pulmonary artery. RESULTS The study included 480 patients, consisting of 240 SCD patients and 240 controls. The positive rate of PE was 4.0%, with a similar rate in both SCD patients and the control group (4.2% vs. 3.8%, p = 0.08). However, SCD patients had significantly lower contrast enhancement of the pulmonary artery than the control group (266.1 ± 90.5 HU vs. 342.2 ± 116.1 HU, p < 0.01). Notably, 25.4% of SCD patients had suboptimal scans. The logistic regression model demonstrated that SCD was significantly associated with suboptimal pulmonary arterial contrast enhancement compared to the control group (OR = 4.4; 95% CI: 2.4-8.3). CONCLUSIONS This study revealed a relatively low positive rate of CTPA in both SCD patients and the control group. However, SCD was significantly associated with suboptimal image quality due to inadequate contrast enhancement of the pulmonary artery. Further research is needed to identify measures that can enhance the quality of CTPA studies in SCD patients and to establish a specific imaging protocol for this patient population.
Collapse
Affiliation(s)
- Ali Hassan
- Department of Radiology, Salmaniya Medical Complex, Manama, Bahrain.
| | - Mohammed Taleb
- Department of Radiology, Salmaniya Medical Complex, Manama, Bahrain
| | - Wafa Hasan
- Department of Radiology, Salmaniya Medical Complex, Manama, Bahrain
| | - Fatema Shehab
- Department of Radiology, Salmaniya Medical Complex, Manama, Bahrain
| | - Reem Maki
- Department of Radiology, Salmaniya Medical Complex, Manama, Bahrain
| | - Nawal Alhamar
- Department of Radiology, Salmaniya Medical Complex, Manama, Bahrain
| |
Collapse
|
4
|
Mahmoudi S, Lange M, Lenga L, Yel I, Koch V, Booz C, Martin S, Bernatz S, Vogl T, Albrecht M, Scholtz JE. Salvaging low contrast abdominal CT studies using noise-optimised virtual monoenergetic image reconstruction. BJR Open 2022; 4:20220006. [PMID: 36105416 PMCID: PMC9446156 DOI: 10.1259/bjro.20220006] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/28/2022] [Revised: 04/21/2022] [Accepted: 04/22/2022] [Indexed: 11/25/2022] Open
Abstract
Objectives To assess the impact of noise-optimised virtual monoenergetic imaging (VMI+) on image quality and diagnostic evaluation in abdominal dual-energy CT scans with impaired portal-venous contrast. Methods We screened 11,746 patients who underwent portal-venous abdominal dual-energy CT for cancer staging between 08/2014 and 11/2019 and identified those with poor portal-venous contrast.Standard linearly-blended image series and VMI+ image series at 40, 50, and 60 keV were reconstructed. Signal-to-noise ratio (SNR) and contrast-to-noise ratio (CNR) of abdominal organs and vascular structures were calculated. Image noise, image contrast and overall image quality were rated by three radiologists using 5-point Likert scale. Results 452 of 11,746 (4%) exams were poorly opacified. We excluded 190 cases due to incomplete datasets or multiple exams of the same patient with a final study group of 262. Highest CNR values in all abdominal organs (liver, 6.4 ± 3.0; kidney, 17.4 ± 7.5; spleen, 8.0 ± 3.5) and vascular structures (aorta, 16.0 ± 7.3; intrahepatic vein, 11.3 ± 4.7; portal vein, 15.5 ± 6.7) were measured at 40 keV VMI+ with significantly superior values compared to all other series. In subjective analysis, highest image contrast was seen at 40 keV VMI+ (4.8 ± 0.4), whereas overall image quality peaked at 50 keV VMI+ (4.2 ± 0.5) with significantly superior results compared to all other series (p < 0.001). Conclusions Image reconstruction using VMI+ algorithm at 50 keV significantly improves image contrast and image quality of originally poorly opacified abdominal CT scans and reduces the number of non-diagnostic scans. Advances in knowledge We validated the impact of VMI+ reconstructions in poorly attenuated DECT studies of the abdomen in a big data cohort.
Collapse
Affiliation(s)
- Scherwin Mahmoudi
- Department of Diagnostic and Interventional Radiology, University Hospital Frankfurt, Theodor-Stern-Kai, Frankfurt, Germany
| | - Marvin Lange
- Department of Diagnostic and Interventional Radiology, University Hospital Frankfurt, Theodor-Stern-Kai, Frankfurt, Germany
| | - Lukas Lenga
- Department of Diagnostic and Interventional Radiology, University Hospital Frankfurt, Theodor-Stern-Kai, Frankfurt, Germany
| | - Ibrahim Yel
- Department of Diagnostic and Interventional Radiology, University Hospital Frankfurt, Theodor-Stern-Kai, Frankfurt, Germany
| | - Vitali Koch
- Department of Diagnostic and Interventional Radiology, University Hospital Frankfurt, Theodor-Stern-Kai, Frankfurt, Germany
| | - Christian Booz
- Department of Diagnostic and Interventional Radiology, University Hospital Frankfurt, Theodor-Stern-Kai, Frankfurt, Germany
| | - Simon Martin
- Department of Diagnostic and Interventional Radiology, University Hospital Frankfurt, Theodor-Stern-Kai, Frankfurt, Germany
| | - Simon Bernatz
- Department of Diagnostic and Interventional Radiology, University Hospital Frankfurt, Theodor-Stern-Kai, Frankfurt, Germany
| | - Thomas Vogl
- Department of Diagnostic and Interventional Radiology, University Hospital Frankfurt, Theodor-Stern-Kai, Frankfurt, Germany
| | - Moritz Albrecht
- Department of Diagnostic and Interventional Radiology, University Hospital Frankfurt, Theodor-Stern-Kai, Frankfurt, Germany
| | - Jan-Erik Scholtz
- Department of Diagnostic and Interventional Radiology, University Hospital Frankfurt, Theodor-Stern-Kai, Frankfurt, Germany
| |
Collapse
|
5
|
How artificial intelligence improves radiological interpretation in suspected pulmonary embolism. Eur Radiol 2022; 32:5831-5842. [PMID: 35316363 PMCID: PMC8938594 DOI: 10.1007/s00330-022-08645-2] [Citation(s) in RCA: 34] [Impact Index Per Article: 17.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/29/2021] [Revised: 12/29/2021] [Accepted: 02/04/2022] [Indexed: 11/05/2022]
Abstract
Objectives To evaluate and compare the diagnostic performances of a commercialized artificial intelligence (AI) algorithm for diagnosing pulmonary embolism (PE) on CT pulmonary angiogram (CTPA) with those of emergency radiologists in routine clinical practice. Methods This was an IRB-approved retrospective multicentric study including patients with suspected PE from September to December 2019 (i.e., during a preliminary evaluation period of an approved AI algorithm). CTPA quality and conclusions by emergency radiologists were retrieved from radiological reports. The gold standard was a retrospective review of CTPA, radiological and clinical reports, AI outputs, and patient outcomes. Diagnostic performance metrics for AI and radiologists were assessed in the entire cohort and depending on CTPA quality. Results Overall, 1202 patients were included (median age: 66.2 years). PE prevalence was 15.8% (190/1202). The AI algorithm detected 219 suspicious PEs, of which 176 were true PEs, including 19 true PEs missed by radiologists. In the cohort, the highest sensitivity and negative predictive values (NPVs) were obtained with AI (92.6% versus 90% and 98.6% versus 98.1%, respectively), while the highest specificity and positive predictive value (PPV) were found with radiologists (99.1% versus 95.8% and 95% versus 80.4%, respectively). Accuracy, specificity, and PPV were significantly higher for radiologists except in subcohorts with poor-to-average injection quality. Radiologists positively evaluated the AI algorithm to improve their diagnostic comfort (55/79 [69.6%]). Conclusion Instead of replacing radiologists, AI for PE detection appears to be a safety net in emergency radiology practice due to high sensitivity and NPV, thereby increasing the self-confidence of radiologists. Key Points • Both the AI algorithm and emergency radiologists showed excellent performance in diagnosing PE on CTPA (sensitivity and specificity ≥ 90%; accuracy ≥ 95%). • The AI algorithm for PE detection can help increase the sensitivity and NPV of emergency radiologists in clinical practice, especially in cases of poor-to-moderate injection quality. • Emergency radiologists recommended the use of AI for PE detection in satisfaction surveys to increase their confidence and comfort in their final diagnosis. Supplementary Information The online version contains supplementary material available at 10.1007/s00330-022-08645-2.
Collapse
|
6
|
Vlahos I, Jacobsen MC, Godoy MC, Stefanidis K, Layman RR. Dual-energy CT in pulmonary vascular disease. Br J Radiol 2022; 95:20210699. [PMID: 34538091 PMCID: PMC8722250 DOI: 10.1259/bjr.20210699] [Citation(s) in RCA: 12] [Impact Index Per Article: 6.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/06/2021] [Revised: 09/01/2021] [Accepted: 09/06/2021] [Indexed: 01/03/2023] Open
Abstract
Dual-energy CT (DECT) imaging is a technique that extends the capabilities of CT beyond that of established densitometric evaluations. CT pulmonary angiography (CTPA) performed with dual-energy technique benefits from both the availability of low kVp CT data and also the concurrent ability to quantify iodine enhancement in the lung parenchyma. Parenchymal enhancement, presented as pulmonary perfused blood volume maps, may be considered as a surrogate of pulmonary perfusion. These distinct capabilities have led to new opportunities in the evaluation of pulmonary vascular diseases. Dual-energy CTPA offers the potential for improvements in pulmonary emboli detection, diagnostic confidence, and most notably severity stratification. Furthermore, the appreciated insights of pulmonary vascular physiology conferred by DECT have resulted in increased use for the assessment of pulmonary hypertension, with particular utility in the subset of patients with chronic thromboembolic pulmonary hypertension. With the increasing availability of dual energy-capable CT systems, dual energy CTPA is becoming a standard-of-care protocol for CTPA acquisition in acute PE. Furthermore, qualitative and quantitative pulmonary vascular DECT data heralds promise for the technique as a "one-stop shop" for diagnosis and surveillance assessment in patients with pulmonary hypertension. This review explores the current application, clinical value, and limitations of DECT imaging in acute and chronic pulmonary vascular conditions. It should be noted that certain manufacturers and investigators prefer alternative terms, such as spectral or multi-energy CT imaging. In this review, the term dual energy is utilised, although readers can consider these terms synonymous for purposes of the principles explained.
Collapse
Affiliation(s)
- Ioannis Vlahos
- Department of Thoracic Imaging, The University of Texas MD Anderson Cancer Center, Houston, TX, USA
| | - Megan C Jacobsen
- Department of Imaging Physics, The University of Texas MD Anderson Cancer Center, Houston, TX, USA
| | - Myrna C Godoy
- Department of Thoracic Imaging, The University of Texas MD Anderson Cancer Center, Houston, TX, USA
| | | | - Rick R Layman
- Department of Imaging Physics, The University of Texas MD Anderson Cancer Center, Houston, TX, USA
| |
Collapse
|
7
|
Kligerman S, Hsiao A. Optimizing the diagnosis and assessment of chronic thromboembolic pulmonary hypertension with advancing imaging modalities. Pulm Circ 2021; 11:20458940211007375. [PMID: 34104420 PMCID: PMC8150458 DOI: 10.1177/20458940211007375] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 10/09/2020] [Accepted: 12/10/2020] [Indexed: 02/05/2023] Open
Abstract
Imaging is key to nearly all aspects of chronic thromboembolic pulmonary hypertension including management for screening, assessing eligibility for pulmonary endarterectomy, and post-operative follow-up. While ventilation/perfusion scintigraphy, the gold standard technique for chronic thromboembolic pulmonary hypertension screening, can have excellent sensitivity, it can be confounded by other etiologies of pulmonary malperfusion, and does not provide structural information to guide operability assessment. Conventional computed tomography pulmonary angiography has high specificity, though findings of chronic thromboembolic pulmonary hypertension can be visually subtle and unrecognized. In addition, computed tomography pulmonary angiography can provide morphologic information to aid in pre-operative workup and assessment of other structural abnormalities. Advances in computed tomography imaging techniques, including dual-energy computed tomography and spectral-detector computed tomography, allow for improved sensitivity and specificity in detecting chronic thromboembolic pulmonary hypertension, comparable to that of ventilation/perfusion scans. Furthermore, these advanced computed tomography techniques, compared with conventional computed tomography, provide additional physiologic data from perfused blood volume maps and improved resolution to better visualize distal chronic thromboembolic pulmonary hypertension, an important consideration for balloon pulmonary angioplasty for inoperable patients. Electrocardiogram-synchronized techniques in electrocardiogram-gated computed tomography can also show further information regarding right ventricular function and structure. While the standard of care in the workup of chronic thromboembolic pulmonary hypertension includes a ventilation/perfusion scan, computed tomography pulmonary angiography, direct catheter angiography, echocardiogram, and coronary angiogram, in the future an electrocardiogram-gated dual-energy computed tomography angiography scan may enable a "one-stop" imaging study to guide diagnosis, operability assessment, and treatment decisions with less radiation exposure and cost than traditional chronic thromboembolic pulmonary hypertension imaging modalities.
Collapse
Affiliation(s)
- Seth Kligerman
- Cardiothoracic Imaging, University of California San Diego, La Jolla, CA, USA
| | - Albert Hsiao
- Cardiothoracic Imaging, University of California San Diego, La Jolla, CA, USA
| |
Collapse
|
8
|
Aldosari S, Sun Z. A Systematic Review of Double Low-dose CT Pulmonary Angiography in Pulmonary Embolism. Curr Med Imaging 2020; 15:453-460. [PMID: 32008552 DOI: 10.2174/1573405614666180813120619] [Citation(s) in RCA: 7] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/21/2017] [Revised: 07/20/2018] [Accepted: 07/31/2018] [Indexed: 02/07/2023]
Abstract
BACKGROUND The aim of this study is to perform a systematic review of the feasibility and clinical application of double low-dose CT pulmonary angiography (CTPA) in the diagnosis of patients with suspected pulmonary embolism. DISCUSSION A total of 13 studies were found to meet selection criteria reporting both low radiation dose (70 or 80 kVp versus 100 or 120 kVp) and low contrast medium dose CTPA protocols. Lowdose CTPA resulted in radiation dose reduction from 29.6% to 87.5% in 12 studies (range: 0.4 to 23.5 mSv), while in one study, radiation dose was increased in the dual-energy CT group when compared to the standard 120 kVp group. CTPA with use of low contrast medium volume (range: 20 to 75 ml) was compared to standard CTPA (range: 50 to 101 ml) in 12 studies with reduction between 25 and 67%, while in the remaining study, low iodine concentration was used with 23% dose reduction achieved. Quantitative assessment of image quality (in terms of signal-to-noise ratio and contrast-to-noise ratio) showed that low-dose CTPA was associated with higher, lower and no change in image quality in 3, 3 and 6 studies, respectively when compared to the standard CTPA protocol. The subjective assessment indicated similar image quality in 11 studies between low-dose and standard CTPA groups, and improved image quality in 1 study with low-dose CTPA. CONCLUSION This review shows that double low-dose CTPA is feasible in the diagnosis of pulmonary embolism with significant reductions in both radiation and contrast medium doses, without compromising diagnostic image quality.
Collapse
Affiliation(s)
- Sultan Aldosari
- Discipline of Medical Radiation Sciences, School of Molecular and Life Sciences, Curtin University, Perth, Australia
| | - Zhonghua Sun
- Discipline of Medical Radiation Sciences, School of Molecular and Life Sciences, Curtin University, Perth, Australia
| |
Collapse
|
9
|
Zhang L, Pelgrim GJ, Yan J, Zhang H, Vliegenthart R, Xie X. Feasibility of bronchial wall quantification in low- and ultralow-dose third-generation dual-source CT: An ex vivo lung study. J Appl Clin Med Phys 2020; 21:218-226. [PMID: 32991062 PMCID: PMC7592972 DOI: 10.1002/acm2.13032] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/08/2019] [Revised: 07/21/2020] [Accepted: 08/27/2020] [Indexed: 11/08/2022] Open
Abstract
PURPOSE To investigate image quality and bronchial wall quantification in low- and ultralow-dose third-generation dual-source computed tomography (CT). METHODS A lung specimen from a formerly healthy male was scanned using third-generation dual-source CT at standard-dose (51 mAs/120 kV, CTDIvol 3.41 mGy), low-dose (1/4th and 1/10th of standard dose), and ultralow-dose setting (1/20th). Low kV (70, 80, 90, and Sn100 kV) scanning was applied in each low/ultralow-dose setting, combined with adaptive mAs to keep a constant dose. Images were reconstructed at advanced modeled iterative reconstruction (ADMIRE) levels 1, 3, and 5 for each scan. Bronchial wall were semi-automatically measured from the lobar level to subsegmental level. Spearman correlation analysis was performed between bronchial wall quantification (wall thickness and wall area percentage) and protocol settings (dose, kV, and ADMIRE). ANOVA with a post hoc pairwise test was used to compare signal-to-noise ratio (SNR), noise and bronchial wall quantification values among standard- and low/ultralow-dose settings, and among ADMIRE levels. RESULTS Bronchial wall quantification had no correlation with dose level, kV, or ADMIRE level (|correlation coefficients| < 0.3). SNR and noise showed no statistically significant differences at different kV in the same ADMIRE level (1, 3, or 5) and in the same dose group (P > 0.05). Generally, there were no significant differences in bronchial wall quantification among the standard- and low/ultralow-dose settings, and among different ADMIRE levels (P > 0.05). CONCLUSION The combined use of low/ultralow-dose scanning and ADMIRE does not influence bronchial wall quantification compared to standard-dose CT. This specimen study suggests the potential that an ultralow-dose scan can be used for bronchial wall quantification.
Collapse
Affiliation(s)
- Lin Zhang
- Radiology Department, Shanghai General Hospital, Shanghai Jiao Tong University School of Medicine, Shanghai, China.,Radiology Department, Shanghai General Hospital of Nanjing Medical University, Shanghai, China
| | - Gert Jan Pelgrim
- Department of Radiology, University of Groningen, University Medical Center Groningen, Groningen, The Netherlands
| | - Jing Yan
- Siemens Healthcare Ltd, Shanghai, China
| | - Hao Zhang
- Radiology Department, Shanghai General Hospital, Shanghai Jiao Tong University School of Medicine, Shanghai, China
| | - Rozemarijn Vliegenthart
- Department of Radiology, University of Groningen, University Medical Center Groningen, Groningen, The Netherlands
| | - Xueqian Xie
- Radiology Department, Shanghai General Hospital, Shanghai Jiao Tong University School of Medicine, Shanghai, China
| |
Collapse
|
10
|
Watanabe R, Funama Y, Takaki T, Oda S, Nakaura T, Murakami S, Aoki T. Additive value of split-bolus single-phase CT scan protocol for preoperative assessment of lung cancer patients referred for video-assisted thoracic surgery. Radiol Phys Technol 2019; 12:409-416. [PMID: 31654374 DOI: 10.1007/s12194-019-00541-7] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/08/2019] [Revised: 10/16/2019] [Accepted: 10/17/2019] [Indexed: 10/25/2022]
Abstract
We aimed to assess the additive value of the split-bolus single-phase computed tomography (CT) scan protocol to preoperatively assess patients with lung cancer, who were referred for video-assisted thoracic surgery, when compared to a standard staging CT protocol. We included 160 patients with lung cancer who underwent a split-bolus single-phase CT scan protocol (split-bolus protocol), which can acquire whole-body staging CT and pulmonary artery-vein separation CT angiography (PA-PV CTA) in a single acquisition and 160 patients who underwent whole-body staging CT (standard protocol). We compared the quality of the staging CT images of hepatic parenchyma, portal vein, and hepatic vein between both protocols. We also investigated image quality on PA-PV CTA images in the split-bolus protocol and recorded the number of patients that underwent the 3D PA-PV CTA imaging process. The split-bolus protocol for staging CT images demonstrated a slightly higher enhancement with regard to the hepatic parenchyma (p = 0.007) and hepatic vein (p = 0.006) than the standard protocol. There was no significant difference in the quality of the staging CT images between both protocols (p = 0.067). The mean CT number for the main pulmonary artery and the left atrium for the PA-PV CTA images in the split-bolus protocol were 289.1 HU and 172.8 HU, respectively. Among the images associated with the split-bolus protocol, 98.1% were of appropriate quality for 3D PA-PV CTA imaging. The split-bolus protocol is a dose-efficient protocol to acquire the staging CT and PA-PV CTA images in a single session and provides sufficient image quality for preoperative assessment in patients with lung cancer.
Collapse
Affiliation(s)
- Ryo Watanabe
- Graduate School of Health Sciences, Kumamoto University, 1-1-1, Honjo, Chuo-ku, Kumamoto, 860-8556, Japan.,Department of Radiology, Hospital of the University of Occupational and Environmental Health, Iseigaoka 1-1, Yahatanishi-ku, Kitakyushu-shi, Fukuoka, 807-8555, Japan
| | - Yoshinori Funama
- Department of Medical Physics, Faculty of Life Sciences, Kumamoto University, 1-1-1, Honjo, Chuo-ku, Kumamoto, 860-8556, Japan.
| | - Takeshi Takaki
- Department of Radiology, Hospital of the University of Occupational and Environmental Health, Iseigaoka 1-1, Yahatanishi-ku, Kitakyushu-shi, Fukuoka, 807-8555, Japan
| | - Seitaro Oda
- Department of Radiology, Kumamoto University Hospital, 1-1-1, Honjo, Chuo-ku, Kumamoto, 860-8556, Japan
| | - Takeshi Nakaura
- Department of Radiology, Kumamoto University Hospital, 1-1-1, Honjo, Chuo-ku, Kumamoto, 860-8556, Japan
| | - Seiichi Murakami
- Department of Radiology, Hospital of the University of Occupational and Environmental Health, Iseigaoka 1-1, Yahatanishi-ku, Kitakyushu-shi, Fukuoka, 807-8555, Japan
| | - Takatoshi Aoki
- Department of Radiology, University of Occupational and Environmental Health School of Medicine, Iseigaoka 1-1, Yahatanishi-ku, Kitakyushu-shi, Fukuoka, 807-8555, Japan
| |
Collapse
|
11
|
Al Hassan DA, Waheed KB, El Sirafy MN, Khattab MA, Al-Hammadi HI, Ibrahim MF, Arulanantham ZJ. Computed tomography pulmonary angiography using high-pitch dual-source scanner technology. Saudi Med J 2019; 40:230-237. [PMID: 30834417 PMCID: PMC6468199 DOI: 10.15537/smj.2019.3.23940] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/18/2023] Open
Abstract
Objectives: To compare use of ultra-fast high-pitch dual-source free-breathing computed tomography pulmonary angiogram (CTPA) with conventional standard-pitch single-source breath-hold CTPA. Methods: This retrospective comparative study was conducted in Radiology Department at King Fahad Military Medical Complex Dhahran, Saudi Arabia from July 2016 to December 2017. Patients (N=130) were divided into 2 groups, each having 65 consecutive patients; Group-1 (single-source CT) and Group-2 (dual-source CT). Previously treated pulmonary embolism cases, pregnant patients and those with incomplete data were excluded. Image quality was subjectively assessed by 2 readers for adequacy of contrast opacification and pulmonary vessel outline, and presence of artifacts (breathing motion, cardiac pulsation, and contrast related). Scan acquisition times and radiation doses were also compared. Chi-square and t-test were used to determine association. Results: Improved image quality (optimal studies without artifacts 91%) was seen in Group-2 compared to Group-1 (optimal studies without artifacts 75.4%). Also, reduced scan time (1-2 sec.) and radiation dose (mean dose length product (DLP)-248 mGy-cm) were observed in Group-2 compared to Group-1 (scan time- 6.5 sec, mean DLP-375). Results were found significant (p<0.05). Conclusion: High-pitch dual-source CT with free-breathing yields better image quality, reduces image acquisition time and radiation doses.
Collapse
Affiliation(s)
- Donya A Al Hassan
- Department of Radiology, King Fahad Military Medical Complex,Prince Sultan Military College of Health Science, Dhahran, Kingdom of Saudi Arabia. E-mail.
| | - Khawaja B Waheed
- Radiology Department, King Fahad Military Medical Complex, Dhahran, Kingdom of Saudi Arabia. E-mail.
| | | | | | | | | | | |
Collapse
|
12
|
Aldosari S, Jansen S, Sun Z. Patient-specific 3D printed pulmonary artery model with simulation of peripheral pulmonary embolism for developing optimal computed tomography pulmonary angiography protocols. Quant Imaging Med Surg 2019; 9:75-85. [PMID: 30788248 PMCID: PMC6351806 DOI: 10.21037/qims.2018.10.13] [Citation(s) in RCA: 15] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/10/2018] [Accepted: 10/26/2018] [Indexed: 11/06/2022]
Abstract
BACKGROUND Computed tomography pulmonary angiography (CTPA) is the preferred imaging modality for diagnosis of patients with suspected pulmonary embolism (PE). Radiation dose associated with CTPA has been significantly reduced due to the use of dose-reduction strategies, however, investigation of low-dose CTPA with use of different kVp and pitch values has not been systematically studied. The aim of this study was to utilize a 3D printed pulmonary model with simulation of small thrombus in the pulmonary arteries for development of optimal CTPA protocols. METHODS Animal blood clots were inserted into the pulmonary arteries to simulate peripheral embolism based on a realistic 3D printed pulmonary artery model. The 3D printed model was scanned with 192-slice 3rd generation dual-source CT with 1 mm slice thickness and 0.5 mm reconstruction interval. All images were reconstructed with advanced modelled iterative reconstruction (IR) at a strength level of 3. CTPA scanning parameters were as follows: 70, 80, 100 and 120 kVp, 0.9, 2.2 and 3.2 pitch values. Quantitative assessment of image quality was determined by measuring signal-to-noise ratio (SNR) in both main pulmonary arteries, while qualitative analysis of images was scored by two experienced radiologists (score of 1 indicates poor visualization of thrombus with no confidence, and score of 5 excellent visualization of thrombus with high confidence) to determine the image quality in relation to different scanning protocols for detection of thrombus in the pulmonary arteries. RESULTS No significant differences were found in SNR measurements among all CTPA protocols (P>0.05), regardless of kVp or pitch values used, although SNR was higher with 120 kVp and 0.9 and 2.2 pitch protocols than that in other protocols. The thrombi were detected in all images, with 70 kVp and 3.2 pitch protocol scored the lowest with a score of 3 by two observers, and images with other protocols were scored 4 or 5. Lowering kVp from 120 to 70 with use of high-pitch 2.2 or 3.2 protocol resulted in up to 80% dose reduction without significantly affecting image quality. CONCLUSIONS Low-dose CT pulmonary angiography protocols comprising 70 kVp and high pitch 2.2 or 3.2 allow for detection of peripheral PE with significant reduction in radiation dose while images are still considered diagnostic.
Collapse
Affiliation(s)
- Sultan Aldosari
- Discipline of Medical Radiation Sciences, School of Molecular and Life Sciences, Curtin University, Perth, Australia
| | - Shirley Jansen
- Department of Vascular and Endovascular Surgery, Sir Charles Gairdner Hospital, Perth, Australia
- Curtin Medical School, Curtin University, Perth, Australia
- Faculty of Health and Medical Sciences, University of Western Australia, Crawley, Australia
- Heart and Vascular Research Institute, Harry Perkins Medical Research Institute, Perth, Australia
| | - Zhonghua Sun
- Discipline of Medical Radiation Sciences, School of Molecular and Life Sciences, Curtin University, Perth, Australia
| |
Collapse
|