1
|
Ghosn Y, Khdhir M, Jabbour Y, Dushfunian D, Kobeissi I, Abbas N, Akkari C, Kahwaji EM, Muallem N. Factors affecting radiation dose, radiation exposure time and procedural time in arterial embolization for active hemorrhage. Emerg Radiol 2024; 31:641-652. [PMID: 38955874 DOI: 10.1007/s10140-024-02262-w] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/20/2024] [Accepted: 06/26/2024] [Indexed: 07/04/2024]
Abstract
PURPOSE To evaluate patient and procedure-related factors contributing to the radiation dose, cumulative fluoroscopy time (CFT), and procedural time (PT) of Arterial Embolization (AE) for suspected active bleeding. METHODS Data on patients who underwent AE for suspected bleeding was retrospectively gathered between January 2019 and April 2022. Data collected included the dependent variables consisting of dose-area product (DAP), CFT, PT, and independent variables consisting of demographic, bleeding-specific, and procedure-specific parameters. All statistical computations were performed in SPSS statistics. The alpha value was set at 0.05. RESULTS Data from a total of 148 AE were collected with an average patient's age of 61.06 ± 21.57 years. Higher DAP was independently associated with male sex (p < 0.002), age ranges between 46 and 65 years (p = 0.019) and > 66 years (p = 0.027), BMI above 30 (p = 0.016), attending with less than 10 years of experience (p = 0.01), and bleeding in the abdomen and pelvis (p = 0.027). Longer CFT was independently associated with attending with less than 10 years of experience (p < 0.001), having 2 (p = 0.004) or > 3 (p = 0.005) foci of bleed, and age between 46 and 65 years (p = 0.007) and ≥ 66 years (p = 0.017). Longer PT was independently associated with attending with less than 10 years of experience (p < 0.001) and having 2 (p = 0.014) or > 3 (p = 0.005) foci of bleed. CONCLUSION The interventionist experience influenced radiation dose, CFT and PT. Dose was also affected by patients' sex, age, BMI, as well as bleeding location. CFT was also affected by patients' age, and both CFT and PT were also affected by the number of bleeding foci. These findings highlight the multifaceted factors that affect radiation dose and procedural time, emphasizing the importance of interventionist expertise, patient's age, sex, BMI, location and number of bleeds.
Collapse
Affiliation(s)
- Youssef Ghosn
- Department of Diagnostic Radiology, American University of Beirut, Riad El-Solh, P.O.Box 11-0236, Beirut, 1107 2020, Lebanon
| | - Mihran Khdhir
- Department of Radiology and Biomedical Imaging, Yale School of Medicine, New Haven, USA
| | - Yara Jabbour
- Department of Diagnostic Radiology, American University of Beirut, Riad El-Solh, P.O.Box 11-0236, Beirut, 1107 2020, Lebanon
| | - David Dushfunian
- Faculty of Medicine, American University of Beirut, Beirut, Lebanon
| | - Iyad Kobeissi
- Faculty of Medicine, American University of Beirut, Beirut, Lebanon
| | - Nada Abbas
- American University of Beirut, Beirut, Lebanon
| | - Chantal Akkari
- Department of Diagnostic Radiology, American University of Beirut, Riad El-Solh, P.O.Box 11-0236, Beirut, 1107 2020, Lebanon
| | - Eva-Maria Kahwaji
- Faculty of Health Science, American University of Berirut, Beirut, Lebanon
| | - Nadim Muallem
- Department of Diagnostic Radiology, American University of Beirut, Riad El-Solh, P.O.Box 11-0236, Beirut, 1107 2020, Lebanon.
| |
Collapse
|
2
|
Doncic N, Zech CJ, Wild D, Bachmann H, Mallaev M, Tsvetkov N, Hojski A, Takes MTL, Lardinois D. CT-guided percutaneous marking of small pulmonary nodules with [ 99mTc]Tc-Macrosalb is very accurate and allows minimally invasive lung-sparing resection: a single-centre quality control. Eur J Nucl Med Mol Imaging 2024; 51:2980-2987. [PMID: 37650931 PMCID: PMC11300552 DOI: 10.1007/s00259-023-06410-1] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/17/2023] [Accepted: 08/21/2023] [Indexed: 09/01/2023]
Abstract
PURPOSE The detection of small lung nodules in thoracoscopic procedure is difficult when the lesions are not located within the outer border of the lung. In the case of ground-glass opacities, it is often impossible to palpate the lesion. Marking lung nodules using a radiotracer is a known technique. We analysed the accuracy and safety of the technique and the potential benefits of operating in a hybrid operating room. METHODS 57 patients, including 33 (58%) females with a median age of 67 years (range 21-82) were included. In 27 patients, we marked and resected the lesion in a hybrid room. In 30 patients, the lesion was marked at the department of radiology the day before resection. [99mTc]Tc-Macrosalb (Pulmocis®) was used at an activity of 1 MBq in the hybrid room and at an activity of 3 MBq the day before to get technical feasible results. Radioactivity was detected using the Neoprobe® detection system. RESULTS Precise detection and resection of the nodules was possible in 95% of the lesions and in 93% of the patients. Complete thoracoscopic resection was possible in 90% of the patients. Total conversion rate was 10%, but conversion due to failure of the marking of the nodule was observed in only 5% of the patients. Histology revealed 28 (37%) primary lung cancers, 24 (32%) metastases and 21 (28%) benign lesions. In 13 (23%) patients, minor complications were observed. None of them required additional interventions. CONCLUSION The radio-guided detection of small pulmonary nodules is very accurate and safe after CT-guided injection of [99mTc]Tc-Macrosalb. Performing the operation in a hybrid room has several logistic advantages and allows using lower technetium-99m activities. The technique allows minimally invasive lung sparing resection and prevents overtreatment of benign and metastatic lesions.
Collapse
Affiliation(s)
- Nikola Doncic
- Department of Thoracic Surgery, University Hospital Basel, Spitalstrasse 21, 4031, Basel, Switzerland
| | - Christoph J Zech
- Department of Radiology and Nuclear Medicine, Division of Interventional Radiology, University Hospital Basel, Basel, Switzerland
| | - Damian Wild
- Department of Radiology and Nuclear Medicine, Division of Nuclear Medicine, University Hospital Basel, Basel, Switzerland
| | - Helga Bachmann
- Department of Thoracic Surgery, University Hospital Basel, Spitalstrasse 21, 4031, Basel, Switzerland
| | - Makhmudbek Mallaev
- Department of Thoracic Surgery, University Hospital Basel, Spitalstrasse 21, 4031, Basel, Switzerland
| | - Nikolay Tsvetkov
- Department of Thoracic Surgery, University Hospital Basel, Spitalstrasse 21, 4031, Basel, Switzerland
| | - Aljaz Hojski
- Department of Thoracic Surgery, University Hospital Basel, Spitalstrasse 21, 4031, Basel, Switzerland
| | - Martin T L Takes
- Department of Radiology and Nuclear Medicine, Division of Interventional Radiology, University Hospital Basel, Basel, Switzerland
| | - Didier Lardinois
- Department of Thoracic Surgery, University Hospital Basel, Spitalstrasse 21, 4031, Basel, Switzerland.
| |
Collapse
|
3
|
Modarai B, Haulon S, Ainsbury E, Böckler D, Vano-Carruana E, Dawson J, Farber M, Van Herzeele I, Hertault A, van Herwaarden J, Patel A, Wanhainen A, Weiss S, Esvs Guidelines Committee, Bastos Gonçalves F, Björck M, Chakfé N, de Borst GJ, Coscas R, Dias NV, Dick F, Hinchliffe RJ, Kakkos SK, Koncar IB, Kolh P, Lindholt JS, Trimarchi S, Tulamo R, Twine CP, Vermassen F, Document Reviewers, Bacher K, Brountzos E, Fanelli F, Fidalgo Domingos LA, Gargiulo M, Mani K, Mastracci TM, Maurel B, Morgan RA, Schneider P. Editor's Choice - European Society for Vascular Surgery (ESVS) 2023 Clinical Practice Guidelines on Radiation Safety. Eur J Vasc Endovasc Surg 2023; 65:171-222. [PMID: 36130680 DOI: 10.1016/j.ejvs.2022.09.005] [Citation(s) in RCA: 42] [Impact Index Per Article: 42.0] [Reference Citation Analysis] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/19/2022] [Accepted: 09/15/2022] [Indexed: 01/24/2023]
|
4
|
Yamamoto S, Matsumoto T, Suda S, Tomita K, Kamei S, Hashida K, Imai Y, Endo K, Murakami K, Hasebe T. First experience of efficacy and radiation exposure in 320-detector row CT fluoroscopy-guided interventions. Br J Radiol 2021; 94:20200754. [PMID: 33544633 DOI: 10.1259/bjr.20200754] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/13/2022] Open
Abstract
OBJECTIVE We investigated the efficacy and exposure to radiation in 320-detector row computed tomography fluoroscopy-guided (CTF-guided) interventions. METHODS We analysed 231 320-detector row CTF-guided interventions (207 patients over 2 years and 6 months) in terms of technical success rates, clinical success rates, complications, scanner settings, overall radiation doses (dose-length product, mGy*cm), patient doses of peri-interventional CT series, and interventional CT (including CTF), as a retrospective cohort study. The relationships between patient radiation dose and interventional factors were assessed using multivariate analysis. RESULTS Overall technical success rate was 98.7% (228/231). The technical success rates of biopsies, drainages, and aspirations were 98.7% (154/156), 98.5% (66/67), and 100% (8/8), respectively. The clinical success rate of biopsies was 93.5% (146/156). All three major complications occurred in chest biopsies. The median total radiation dose was 522.4 (393.4-819.8) mGy*cm. Of the total radiation dose, 87% was applied during the pre- and post-interventional CT series. Post-interventional CT accounted for 24.4% of the total radiation dose. Only 11.4% of the dose was applied by CTF-guided intervention. Multilinear regression demonstrated that male sex, body mass index, drainage, intervention time, and helical scan as post-interventional CT were significantly associated with higher dose. CONCLUSION The 320-detector row CTF interventions achieved a high success rate. Dose reduction in post-interventional CT provides patient dose reduction without decreasing the technical success rates. ADVANCES IN KNOWLEDGE This is the first study on the relationship between various interventional outcomes and patient exposure to radiation in 320-detector row CTF-guided interventions, suggesting a new perspective on dose reduction.
Collapse
Affiliation(s)
- Shota Yamamoto
- Department of Radiology, Tokai University Hachioji Hospital, Tokai University School of Medicine, 1838 Ishikawa-machi, Hachioji, Tokyo, Japan
| | - Tomohiro Matsumoto
- Department of Radiology, Tokai University Hachioji Hospital, Tokai University School of Medicine, 1838 Ishikawa-machi, Hachioji, Tokyo, Japan
| | - Satoshi Suda
- Department of Radiology, Tokai University Hachioji Hospital, Tokai University School of Medicine, 1838 Ishikawa-machi, Hachioji, Tokyo, Japan
| | - Kosuke Tomita
- Department of Radiology, Tokai University Hachioji Hospital, Tokai University School of Medicine, 1838 Ishikawa-machi, Hachioji, Tokyo, Japan
| | - Shunsuke Kamei
- Department of Radiology, Tokai University Hachioji Hospital, Tokai University School of Medicine, 1838 Ishikawa-machi, Hachioji, Tokyo, Japan
| | - Kazunobu Hashida
- Department of Radiology, Tokai University Hachioji Hospital, Tokai University School of Medicine, 1838 Ishikawa-machi, Hachioji, Tokyo, Japan
| | - Yutaka Imai
- Department of Radiology, Tokai University Hachioji Hospital, Tokai University School of Medicine, 1838 Ishikawa-machi, Hachioji, Tokyo, Japan
| | - Kazuyuki Endo
- Department of Radiological technology, Tokai University Hachioji Hospital, Tokai University School of Medicine, 1838 Ishikawa-machi, Hachioji, Tokyo, Japan
| | - Katsuki Murakami
- Department of Radiological technology, Tokai University Hachioji Hospital, Tokai University School of Medicine, 1838 Ishikawa-machi, Hachioji, Tokyo, Japan
| | - Terumitsu Hasebe
- Department of Radiology, Tokai University Hachioji Hospital, Tokai University School of Medicine, 1838 Ishikawa-machi, Hachioji, Tokyo, Japan
| |
Collapse
|
5
|
Theilig D, Mayerhofer A, Petschelt D, Elkilany A, Hamm B, Gebauer B, Geisel D. Impact of interventionalist's experience and gender on radiation dose and procedural time in CT-guided interventions-a retrospective analysis of 4380 cases over 10 years. Eur Radiol 2020; 31:569-579. [PMID: 32851446 PMCID: PMC8263432 DOI: 10.1007/s00330-020-07185-x] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/28/2020] [Revised: 06/30/2020] [Accepted: 08/12/2020] [Indexed: 11/09/2022]
Abstract
Objectives To investigate the impact of the interventionalist’s experience and gender on radiation dose and procedural time in CT-guided interventions. Methods We retrospectively analyzed 4380 CT-guided interventions performed at our institution with the same CT scanner from 2009 until 2018, 1287 (29%) by female and 3093 (71%) by male interventionalists. Radiation dose, number of CT fluoroscopy images taken per intervention, total procedural time, type of intervention, and degree of difficulty were derived from the saved dose reports and images. All 16 interventionalists included in this analysis performed their first CT-guided interventions during the study period, and interventions performed by each interventionalist were counted to assess the level of experience for each intervention in terms of the number of prior interventions performed by her or him. The Mann-Whitney U test (MWU test), multivariate regression, and linear mixed model analysis were performed. Results Assessment of the impact of gender with the MWU test revealed that female interventionalists took a significantly smaller number of images (p < 0.0001) and achieved a lower dose-length product per intervention (p < 0.0001) while taking more time per intervention (p = 0.0001). This finding was confirmed for most types of interventions when additionally accounting for other possible impact factors in multivariate regression analysis. In linear mixed model analysis, we found that radiation dose, number of images taken per intervention, and procedural time decreased statistically significantly with interventionalist’s experience. Conclusions Radiation doses of CT-guided interventions are reduced by interventionalist’s experience and, for most types of interventions, when performed by female interventionalists. Key Points • Radiation doses in CT-guided interventions are lower when performed by female interventionalists. • Procedural times of CT-guided interventions are longer when performed by female interventionalists. • Radiation doses of CT-guided interventions decrease with the interventionalist’s experience. Electronic supplementary material The online version of this article (10.1007/s00330-020-07185-x) contains supplementary material, which is available to authorized users.
Collapse
Affiliation(s)
- Dorothea Theilig
- Charité - Universitätsmedizin Berlin, corporate member of Freie Universität Berlin, Humboldt-Universität zu Berlin, Department of Diagnostic and Interventional Radiology, Augustenburger Platz 1, 13353, Berlin, Germany.
| | - Anna Mayerhofer
- Charité - Universitätsmedizin Berlin, corporate member of Freie Universität Berlin, Humboldt-Universität zu Berlin, Department of Diagnostic and Interventional Radiology, Augustenburger Platz 1, 13353, Berlin, Germany
| | - David Petschelt
- Charité - Universitätsmedizin Berlin, corporate member of Freie Universität Berlin, Humboldt-Universität zu Berlin, Department of Diagnostic and Interventional Radiology, Augustenburger Platz 1, 13353, Berlin, Germany
| | - Aboelyazid Elkilany
- Charité - Universitätsmedizin Berlin, corporate member of Freie Universität Berlin, Humboldt-Universität zu Berlin, Department of Diagnostic and Interventional Radiology, Augustenburger Platz 1, 13353, Berlin, Germany
| | - Bernd Hamm
- Charité - Universitätsmedizin Berlin, corporate member of Freie Universität Berlin, Humboldt-Universität zu Berlin, Department of Diagnostic and Interventional Radiology, Augustenburger Platz 1, 13353, Berlin, Germany
| | - Bernhard Gebauer
- Charité - Universitätsmedizin Berlin, corporate member of Freie Universität Berlin, Humboldt-Universität zu Berlin, Department of Diagnostic and Interventional Radiology, Augustenburger Platz 1, 13353, Berlin, Germany
| | - Dominik Geisel
- Charité - Universitätsmedizin Berlin, corporate member of Freie Universität Berlin, Humboldt-Universität zu Berlin, Department of Diagnostic and Interventional Radiology, Augustenburger Platz 1, 13353, Berlin, Germany
| |
Collapse
|