1
|
Ye K, Xu L, Pan B, Li J, Li M, Yuan H, Gong NJ. Deep learning-based image domain reconstruction enhances image quality and pulmonary nodule detection in ultralow-dose CT with adaptive statistical iterative reconstruction-V. Eur Radiol 2025:10.1007/s00330-024-11317-y. [PMID: 39792163 DOI: 10.1007/s00330-024-11317-y] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/22/2024] [Revised: 11/06/2024] [Accepted: 11/28/2024] [Indexed: 01/12/2025]
Abstract
OBJECTIVES To evaluate the image quality and lung nodule detectability of ultralow-dose CT (ULDCT) with adaptive statistical iterative reconstruction-V (ASiR-V) post-processed using a deep learning image reconstruction (DLIR)-based image domain compared to low-dose CT (LDCT) and ULDCT without DLIR. MATERIALS AND METHODS A total of 210 patients undergoing lung cancer screening underwent LDCT (mean ± SD, 0.81 ± 0.28 mSv) and ULDCT (0.17 ± 0.03 mSv) scans. ULDCT images were reconstructed with ASiR-V (ULDCT-ASiR-V) and post-processed using DLIR (ULDCT-DLIR). The quality of the three CT images was analyzed. Three radiologists detected and measured pulmonary nodules on all CT images, with LDCT results serving as references. Nodule conspicuity was assessed using a five-point Likert scale, followed by further statistical analyses. RESULTS A total of 463 nodules were detected using LDCT. The image noise of ULDCT-DLIR decreased by 60% compared to that of ULDCT-ASiR-V and was lower than that of LDCT (p < 0.001). The subjective image quality scores for ULDCT-DLIR (4.4 [4.1, 4.6]) were also higher than those for ULDCT-ASiR-V (3.6 [3.1, 3.9]) (p < 0.001). The overall nodule detection rates for ULDCT-ASiR-V and ULDCT-DLIR were 82.1% (380/463) and 87.0% (403/463), respectively (p < 0.001). The percentage difference between diameters > 1 mm was 2.9% (ULDCT-ASiR-V vs. LDCT) and 0.5% (ULDCT-DLIR vs. LDCT) (p = 0.009). Scores of nodule imaging sharpness on ULDCT-DLIR (4.0 ± 0.68) were significantly higher than those on ULDCT-ASiR-V (3.2 ± 0.50) (p < 0.001). CONCLUSION DLIR-based image domain improves image quality, nodule detection rate, nodule imaging sharpness, and nodule measurement accuracy of ASiR-V on ULDCT. KEY POINTS Question Deep learning post-processing is simple and cheap compared with raw data processing, but its performance is not clear on ultralow-dose CT. Findings Deep learning post-processing enhanced image quality and improved the nodule detection rate and accuracy of nodule measurement of ultralow-dose CT. Clinical relevance Deep learning post-processing improves the practicability of ultralow-dose CT and makes it possible for patients with less radiation exposure during lung cancer screening.
Collapse
Affiliation(s)
- Kai Ye
- Department of Radiology, Peking University Third Hospital, Beijing, China
| | - Libo Xu
- Laboratory for Intelligent Medical Imaging, Tsinghua Cross-strait Research Institute, Xiamen, China
| | | | - Jie Li
- Department of Radiology, Clinical Oncology School of Fujian Medical University, Fujian Cancer Hospital, Fuzhou, China
| | - Meijiao Li
- Department of Radiology, Peking University Third Hospital, Beijing, China
| | - Huishu Yuan
- Department of Radiology, Peking University Third Hospital, Beijing, China.
| | - Nan-Jie Gong
- Shanghai Key Laboratory of Magnetic Resonance, School of Physics and Electronic Science, East China Normal University, Shanghai, China.
- Institute of Magnetic Resonance and Molecular Imaging in Medicine, East China Normal University, Shanghai, China.
| |
Collapse
|
2
|
Luo W, Ren Y, Liu Y, Deng J, Huang X. Imaging diagnostics of pulmonary ground-glass nodules: a narrative review with current status and future directions. Quant Imaging Med Surg 2024; 14:6123-6146. [PMID: 39144060 PMCID: PMC11320543 DOI: 10.21037/qims-24-674] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/31/2024] [Accepted: 06/21/2024] [Indexed: 08/16/2024]
Abstract
Background and Objective The incidence rate of lung cancer, which also has the highest mortality rates for both men and women worldwide, is increasing globally. Due to advancements in imaging technology and the growing inclination of individuals to undergo screening, the detection rate of ground-glass nodules (GGNs) has surged rapidly. Currently, artificial intelligence (AI) methods for data analysis and interpretation, image processing, illness diagnosis, and lesion prediction offer a novel perspective on the diagnosis of GGNs. This article aimed to examine how to detect malignant lesions as early as possible and improve clinical diagnostic and treatment decisions by identifying benign and malignant lesions using imaging data. It also aimed to describe the use of computed tomography (CT)-guided biopsies and highlight developments in AI techniques in this area. Methods We used PubMed, Elsevier ScienceDirect, Springer Database, and Google Scholar to search for information relevant to the article's topic. We gathered, examined, and interpreted relevant imaging resources from the Second Affiliated Hospital of Nanchang University's Imaging Center. Additionally, we used Adobe Illustrator 2020 to process all the figures. Key Content and Findings We examined the common signs of GGNs, elucidated the relationship between these signs and the identification of benign and malignant lesions, and then described the application of AI in image segmentation, automatic classification, and the invasiveness prediction of GGNs over the last three years, including its limitations and outlook. We also discussed the necessity of conducting biopsies of persistent pure GGNs. Conclusions A variety of imaging features can be combined to improve the diagnosis of benign and malignant GGNs. The use of CT-guided puncture biopsy to clarify the nature of lesions should be considered with caution. The development of new AI tools brings new possibilities and hope to improving the ability of imaging physicians to analyze GGN images and achieving accurate diagnosis.
Collapse
Affiliation(s)
- Wenting Luo
- The Second Clinical Medical College, Nanchang University, Nanchang, China
| | - Yifei Ren
- The Second Clinical Medical College, Nanchang University, Nanchang, China
| | - Yinuo Liu
- The Second Clinical Medical College, Nanchang University, Nanchang, China
| | - Jun Deng
- The Second Clinical Medical College, Nanchang University, Nanchang, China
- Department of Radiology, The Second Affiliated Hospital of Nanchang University, Nanchang, China
- Intelligent Medical Imaging of Jiangxi Key Laboratory, Nanchang, China
| | - Xiaoning Huang
- The Second Clinical Medical College, Nanchang University, Nanchang, China
- Department of Radiology, The Second Affiliated Hospital of Nanchang University, Nanchang, China
- Intelligent Medical Imaging of Jiangxi Key Laboratory, Nanchang, China
| |
Collapse
|
3
|
Klemenz AC, Beckert L, Manzke M, Lang CI, Weber MA, Meinel FG. Influence of Deep Learning Based Image Reconstruction on Quantitative Results of Coronary Artery Calcium Scoring. Acad Radiol 2024; 31:2259-2267. [PMID: 38582685 DOI: 10.1016/j.acra.2024.03.020] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/10/2024] [Revised: 03/05/2024] [Accepted: 03/18/2024] [Indexed: 04/08/2024]
Abstract
RATIONALE AND OBJECTIVES To assess the impact of deep learning-based imaging reconstruction (DLIR) on quantitative results of coronary artery calcium scoring (CACS) and to evaluate the potential of DLIR for radiation dose reduction in CACS. METHODS For a retrospective cohort of 100 consecutive patients (mean age 62 ±10 years, 40% female), CACS scans were reconstructed with filtered back projection (FBP), adaptive statistical iterative reconstruction (ASiR-V in 30%, 60% and 90% strength) and DLIR in low, medium and high strength. CACS was quantified semi-automatically and compared between image reconstructions. In a phantom study, a cardiac calcification insert was scanned inside an anthropomorphic thorax phantom at standard dose, 50% dose and 25% dose. FBP reconstructions at standard dose served as the reference standard. RESULTS In the patient study, DLIR led to a mean underestimation of Agatston score by 3.5, 6.4 and 11.6 points at low, medium and high strength, respectively. This underestimation of Agatston score was less pronounced for DLIR than for ASiR-V. In the phantom study, quantitative CACS results increased with reduced radiation dose and decreased with increasing strength of DLIR. Medium strength DLIR reconstruction at 50% dose reduction and high strength DLIR reconstruction at 75% dose reduction resulted in quantitative CACS results that were comparable to FBP reconstructions at standard dose. CONCLUSION Compared to FBP as the historical reference standard, DLIR leads to an underestimation of CACS but this underestimation is more moderate than with ASiR-V. DLIR can offset the increase in image noise and calcium score at reduced dose and may thus allow for substantial radiation dose reductions in CACS studies.
Collapse
Affiliation(s)
- Ann-Christin Klemenz
- Institute of Diagnostic and Interventional Radiology, Pediatric Radiology and Neuroradiology, University Medical Center Rostock, Schillingallee 36, 18057 Rostock, Germany
| | - Lynn Beckert
- Institute of Diagnostic and Interventional Radiology, Pediatric Radiology and Neuroradiology, University Medical Center Rostock, Schillingallee 36, 18057 Rostock, Germany
| | - Mathias Manzke
- Institute of Diagnostic and Interventional Radiology, Pediatric Radiology and Neuroradiology, University Medical Center Rostock, Schillingallee 36, 18057 Rostock, Germany
| | - Cajetan I Lang
- Department of Cardiology, University Medical Center Rostock, Rostock, Germany
| | - Marc-André Weber
- Institute of Diagnostic and Interventional Radiology, Pediatric Radiology and Neuroradiology, University Medical Center Rostock, Schillingallee 36, 18057 Rostock, Germany
| | - Felix G Meinel
- Institute of Diagnostic and Interventional Radiology, Pediatric Radiology and Neuroradiology, University Medical Center Rostock, Schillingallee 36, 18057 Rostock, Germany.
| |
Collapse
|
4
|
Im JY, Halliburton SS, Mei K, Perkins AE, Wong E, Roshkovan L, Sandvold OF, Liu LP, Gang GJ, Noël PB. Patient-derived PixelPrint phantoms for evaluating clinical imaging performance of a deep learning CT reconstruction algorithm. Phys Med Biol 2024; 69:115009. [PMID: 38604190 PMCID: PMC11097966 DOI: 10.1088/1361-6560/ad3dba] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/18/2023] [Revised: 03/22/2024] [Accepted: 04/11/2024] [Indexed: 04/13/2024]
Abstract
Objective. Deep learning reconstruction (DLR) algorithms exhibit object-dependent resolution and noise performance. Thus, traditional geometric CT phantoms cannot fully capture the clinical imaging performance of DLR. This study uses a patient-derived 3D-printed PixelPrint lung phantom to evaluate a commercial DLR algorithm across a wide range of radiation dose levels.Method. The lung phantom used in this study is based on a patient chest CT scan containing ground glass opacities and was fabricated using PixelPrint 3D-printing technology. The phantom was placed inside two different size extension rings to mimic a small- and medium-sized patient and was scanned on a conventional CT scanner at exposures between 0.5 and 20 mGy. Each scan was reconstructed using filtered back projection (FBP), iterative reconstruction, and DLR at five levels of denoising. Image noise, contrast to noise ratio (CNR), root mean squared error, structural similarity index (SSIM), and multi-scale SSIM (MS SSIM) were calculated for each image.Results.DLR demonstrated superior performance compared to FBP and iterative reconstruction for all measured metrics in both phantom sizes, with better performance for more aggressive denoising levels. DLR was estimated to reduce dose by 25%-83% in the small phantom and by 50%-83% in the medium phantom without decreasing image quality for any of the metrics measured in this study. These dose reduction estimates are more conservative compared to the estimates obtained when only considering noise and CNR.Conclusion. DLR has the capability of producing diagnostic image quality at up to 83% lower radiation dose, which can improve the clinical utility and viability of lower dose CT scans. Furthermore, the PixelPrint phantom used in this study offers an improved testing environment with more realistic tissue structures compared to traditional CT phantoms, allowing for structure-based image quality evaluation beyond noise and contrast-based assessments.
Collapse
Affiliation(s)
- Jessica Y Im
- Department of Radiology, University of Pennsylvania, Philadelphia, PA, United States of America
- Department of Bioengineering, University of Pennsylvania, Philadelphia, PA, United States of America
| | | | - Kai Mei
- Department of Radiology, University of Pennsylvania, Philadelphia, PA, United States of America
| | - Amy E Perkins
- Philips Healthcare, Cleveland, OH, United States of America
| | - Eddy Wong
- Philips Healthcare, Cleveland, OH, United States of America
| | - Leonid Roshkovan
- Department of Radiology, University of Pennsylvania, Philadelphia, PA, United States of America
| | - Olivia F Sandvold
- Department of Radiology, University of Pennsylvania, Philadelphia, PA, United States of America
- Department of Bioengineering, University of Pennsylvania, Philadelphia, PA, United States of America
| | - Leening P Liu
- Department of Radiology, University of Pennsylvania, Philadelphia, PA, United States of America
- Department of Bioengineering, University of Pennsylvania, Philadelphia, PA, United States of America
| | - Grace J Gang
- Department of Radiology, University of Pennsylvania, Philadelphia, PA, United States of America
| | - Peter B Noël
- Department of Radiology, University of Pennsylvania, Philadelphia, PA, United States of America
| |
Collapse
|
5
|
Klemenz AC, Albrecht L, Manzke M, Dalmer A, Böttcher B, Surov A, Weber MA, Meinel FG. Improved image quality in CT pulmonary angiography using deep learning-based image reconstruction. Sci Rep 2024; 14:2494. [PMID: 38291105 PMCID: PMC10827738 DOI: 10.1038/s41598-024-52517-2] [Citation(s) in RCA: 2] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/20/2023] [Accepted: 01/19/2024] [Indexed: 02/01/2024] Open
Abstract
We investigated the effect of deep learning-based image reconstruction (DLIR) compared to iterative reconstruction on image quality in CT pulmonary angiography (CTPA) for suspected pulmonary embolism (PE). For 220 patients with suspected PE, CTPA studies were reconstructed using filtered back projection (FBP), adaptive statistical iterative reconstruction (ASiR-V 30%, 60% and 90%) and DLIR (low, medium and high strength). Contrast-to-noise ratio (CNR) served as the primary parameter of objective image quality. Subgroup analyses were performed for normal weight, overweight and obese individuals. For patients with confirmed PE (n = 40), we further measured PE-specific CNR. Subjective image quality was assessed independently by two experienced radiologists. CNR was lowest for FBP and enhanced with increasing levels of ASiR-V and, even more with increasing strength of DLIR. High strength DLIR resulted in an additional improvement in CNR by 29-67% compared to ASiR-V 90% (p < 0.05). PE-specific CNR increased by 75% compared to ASiR-V 90% (p < 0.05). Subjective image quality was significantly higher for medium and high strength DLIR compared to all other image reconstructions (p < 0.05). In CT pulmonary angiography, DLIR significantly outperforms iterative reconstruction for increasing objective and subjective image quality. This may allow for further reductions in radiation exposure in suspected PE.
Collapse
Affiliation(s)
- Ann-Christin Klemenz
- Institute of Diagnostic and Interventional Radiology, Pediatric Radiology and Neuroradiology, University Medical Centre Rostock, Schillingallee 36, 18057, Rostock, Germany
| | - Lasse Albrecht
- Institute of Diagnostic and Interventional Radiology, Pediatric Radiology and Neuroradiology, University Medical Centre Rostock, Schillingallee 36, 18057, Rostock, Germany
| | - Mathias Manzke
- Institute of Diagnostic and Interventional Radiology, Pediatric Radiology and Neuroradiology, University Medical Centre Rostock, Schillingallee 36, 18057, Rostock, Germany
| | - Antonia Dalmer
- Institute of Diagnostic and Interventional Radiology, Pediatric Radiology and Neuroradiology, University Medical Centre Rostock, Schillingallee 36, 18057, Rostock, Germany
| | - Benjamin Böttcher
- Institute of Diagnostic and Interventional Radiology, Pediatric Radiology and Neuroradiology, University Medical Centre Rostock, Schillingallee 36, 18057, Rostock, Germany
| | - Alexey Surov
- Department of Radiology, Mühlenkreiskliniken Minden, Ruhr-University Bochum, Bochum, Germany
| | - Marc-André Weber
- Institute of Diagnostic and Interventional Radiology, Pediatric Radiology and Neuroradiology, University Medical Centre Rostock, Schillingallee 36, 18057, Rostock, Germany
| | - Felix G Meinel
- Institute of Diagnostic and Interventional Radiology, Pediatric Radiology and Neuroradiology, University Medical Centre Rostock, Schillingallee 36, 18057, Rostock, Germany.
| |
Collapse
|
6
|
Im JY, Halliburton SS, Mei K, Perkins AE, Wong E, Roshkovan L, Sandvold OF, Liu LP, Gang GJ, Noël PB. Patient-derived PixelPrint phantoms for evaluating clinical imaging performance of a deep learning CT reconstruction algorithm. MEDRXIV : THE PREPRINT SERVER FOR HEALTH SCIENCES 2023:2023.12.07.23299625. [PMID: 38106064 PMCID: PMC10723564 DOI: 10.1101/2023.12.07.23299625] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 12/19/2023]
Abstract
Objective Deep learning reconstruction (DLR) algorithms exhibit object-dependent resolution and noise performance. Thus, traditional geometric CT phantoms cannot fully capture the clinical imaging performance of DLR. This study uses a patient-derived 3D-printed PixelPrint lung phantom to evaluate a commercial DLR algorithm across a wide range of radiation dose levels. Approach The lung phantom used in this study is based on a patient chest CT scan containing ground glass opacities and was fabricated using PixelPrint 3D-printing technology. The phantom was placed inside two different sized extension rings to mimic a small and medium sized patient and was scanned on a conventional CT scanner at exposures between 0.5 and 20 mGy. Each scan was reconstructed using filtered back projection (FBP), iterative reconstruction, and DLR at five levels of denoising. Image noise, contrast to noise ratio (CNR), root mean squared error (RMSE), structural similarity index (SSIM), and multi-scale SSIM (MS SSIM) were calculated for each image. Main Results DLR demonstrated superior performance compared to FBP and iterative reconstruction for all measured metrics in both phantom sizes, with better performance for more aggressive denoising levels. DLR was estimated to reduce dose by 25-83% in the small phantom and by 50-83% in the medium phantom without decreasing image quality for any of the metrics measured in this study. These dose reduction estimates are more conservative compared to the estimates obtained when only considering noise and CNR with a non-anatomical physics phantom. Significance DLR has the capability of producing diagnostic image quality at up to 83% lower radiation dose which can improve the clinical utility and viability of lower dose CT scans. Furthermore, the PixelPrint phantom used in this study offers an improved testing environment with more realistic tissue structures compared to traditional CT phantoms, allowing for structure-based image quality evaluation beyond noise and contrast-based assessments.
Collapse
|
7
|
Adams SJ, Mikhael P, Wohlwend J, Barzilay R, Sequist LV, Fintelmann FJ. Artificial Intelligence and Machine Learning in Lung Cancer Screening. Thorac Surg Clin 2023; 33:401-409. [PMID: 37806742 DOI: 10.1016/j.thorsurg.2023.03.001] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/10/2023]
Abstract
Recent advances in artificial intelligence and machine learning (AI/ML) hold substantial promise to address some of the current challenges in lung cancer screening and improve health equity. This article reviews the status and future directions of AI/ML tools in the lung cancer screening workflow, focusing on determining screening eligibility, radiation dose reduction and image denoising for low-dose chest computed tomography (CT), lung nodule detection, lung nodule classification, and determining optimal screening intervals. AI/ML tools can assess for chronic diseases on CT, which creates opportunities to improve population health through opportunistic screening.
Collapse
Affiliation(s)
- Scott J Adams
- Department of Radiology, Stanford University School of Medicine, Stanford, CA, USA
| | - Peter Mikhael
- Department of Electrical Engineering and Computer Science, Massachusetts Institute of Technology, Cambridge, MA, USA; Jameel Clinic, Massachusetts Institute of Technology, Cambridge, MA, USA
| | - Jeremy Wohlwend
- Department of Electrical Engineering and Computer Science, Massachusetts Institute of Technology, Cambridge, MA, USA; Jameel Clinic, Massachusetts Institute of Technology, Cambridge, MA, USA
| | - Regina Barzilay
- Department of Electrical Engineering and Computer Science, Massachusetts Institute of Technology, Cambridge, MA, USA; Jameel Clinic, Massachusetts Institute of Technology, Cambridge, MA, USA
| | - Lecia V Sequist
- Department of Medicine, Massachusetts General Hospital, Harvard Medical School, 55 Fruit Street, Boston, MA 02114, USA; Harvard Medical School, Boston, MA, USA.
| | - Florian J Fintelmann
- Harvard Medical School, Boston, MA, USA; Department of Radiology, Massachusetts General Hospital, 55 Fruit Street, Boston, MA 02114, USA.
| |
Collapse
|
8
|
Cellina M, Cacioppa LM, Cè M, Chiarpenello V, Costa M, Vincenzo Z, Pais D, Bausano MV, Rossini N, Bruno A, Floridi C. Artificial Intelligence in Lung Cancer Screening: The Future Is Now. Cancers (Basel) 2023; 15:4344. [PMID: 37686619 PMCID: PMC10486721 DOI: 10.3390/cancers15174344] [Citation(s) in RCA: 17] [Impact Index Per Article: 8.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/10/2023] [Revised: 08/27/2023] [Accepted: 08/28/2023] [Indexed: 09/10/2023] Open
Abstract
Lung cancer has one of the worst morbidity and fatality rates of any malignant tumour. Most lung cancers are discovered in the middle and late stages of the disease, when treatment choices are limited, and patients' survival rate is low. The aim of lung cancer screening is the identification of lung malignancies in the early stage of the disease, when more options for effective treatments are available, to improve the patients' outcomes. The desire to improve the efficacy and efficiency of clinical care continues to drive multiple innovations into practice for better patient management, and in this context, artificial intelligence (AI) plays a key role. AI may have a role in each process of the lung cancer screening workflow. First, in the acquisition of low-dose computed tomography for screening programs, AI-based reconstruction allows a further dose reduction, while still maintaining an optimal image quality. AI can help the personalization of screening programs through risk stratification based on the collection and analysis of a huge amount of imaging and clinical data. A computer-aided detection (CAD) system provides automatic detection of potential lung nodules with high sensitivity, working as a concurrent or second reader and reducing the time needed for image interpretation. Once a nodule has been detected, it should be characterized as benign or malignant. Two AI-based approaches are available to perform this task: the first one is represented by automatic segmentation with a consequent assessment of the lesion size, volume, and densitometric features; the second consists of segmentation first, followed by radiomic features extraction to characterize the whole abnormalities providing the so-called "virtual biopsy". This narrative review aims to provide an overview of all possible AI applications in lung cancer screening.
Collapse
Affiliation(s)
- Michaela Cellina
- Radiology Department, Fatebenefratelli Hospital, ASST Fatebenefratelli Sacco, 20121 Milano, Italy;
| | - Laura Maria Cacioppa
- Department of Clinical, Special and Dental Sciences, University Politecnica delle Marche, 60126 Ancona, Italy; (L.M.C.); (N.R.); (A.B.)
- Division of Interventional Radiology, Department of Radiological Sciences, University Hospital “Azienda Ospedaliera Universitaria delle Marche”, 60126 Ancona, Italy
| | - Maurizio Cè
- Postgraduation School in Radiodiagnostics, Università degli Studi di Milano, 20122 Milan, Italy; (M.C.); (V.C.); (M.C.); (Z.V.); (D.P.); (M.V.B.)
| | - Vittoria Chiarpenello
- Postgraduation School in Radiodiagnostics, Università degli Studi di Milano, 20122 Milan, Italy; (M.C.); (V.C.); (M.C.); (Z.V.); (D.P.); (M.V.B.)
| | - Marco Costa
- Postgraduation School in Radiodiagnostics, Università degli Studi di Milano, 20122 Milan, Italy; (M.C.); (V.C.); (M.C.); (Z.V.); (D.P.); (M.V.B.)
| | - Zakaria Vincenzo
- Postgraduation School in Radiodiagnostics, Università degli Studi di Milano, 20122 Milan, Italy; (M.C.); (V.C.); (M.C.); (Z.V.); (D.P.); (M.V.B.)
| | - Daniele Pais
- Postgraduation School in Radiodiagnostics, Università degli Studi di Milano, 20122 Milan, Italy; (M.C.); (V.C.); (M.C.); (Z.V.); (D.P.); (M.V.B.)
| | - Maria Vittoria Bausano
- Postgraduation School in Radiodiagnostics, Università degli Studi di Milano, 20122 Milan, Italy; (M.C.); (V.C.); (M.C.); (Z.V.); (D.P.); (M.V.B.)
| | - Nicolò Rossini
- Department of Clinical, Special and Dental Sciences, University Politecnica delle Marche, 60126 Ancona, Italy; (L.M.C.); (N.R.); (A.B.)
| | - Alessandra Bruno
- Department of Clinical, Special and Dental Sciences, University Politecnica delle Marche, 60126 Ancona, Italy; (L.M.C.); (N.R.); (A.B.)
| | - Chiara Floridi
- Department of Clinical, Special and Dental Sciences, University Politecnica delle Marche, 60126 Ancona, Italy; (L.M.C.); (N.R.); (A.B.)
- Division of Interventional Radiology, Department of Radiological Sciences, University Hospital “Azienda Ospedaliera Universitaria delle Marche”, 60126 Ancona, Italy
- Division of Radiology, Department of Radiological Sciences, University Hospital “Azienda Ospedaliera Universitaria delle Marche”, 60126 Ancona, Italy
| |
Collapse
|
9
|
Lell M, Kachelrieß M. Computed Tomography 2.0: New Detector Technology, AI, and Other Developments. Invest Radiol 2023; 58:587-601. [PMID: 37378467 PMCID: PMC10332658 DOI: 10.1097/rli.0000000000000995] [Citation(s) in RCA: 9] [Impact Index Per Article: 4.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/27/2023] [Revised: 05/04/2023] [Indexed: 06/29/2023]
Abstract
ABSTRACT Computed tomography (CT) dramatically improved the capabilities of diagnostic and interventional radiology. Starting in the early 1970s, this imaging modality is still evolving, although tremendous improvements in scan speed, volume coverage, spatial and soft tissue resolution, as well as dose reduction have been achieved. Tube current modulation, automated exposure control, anatomy-based tube voltage (kV) selection, advanced x-ray beam filtration, and iterative image reconstruction techniques improved image quality and decreased radiation exposure. Cardiac imaging triggered the demand for high temporal resolution, volume acquisition, and high pitch modes with electrocardiogram synchronization. Plaque imaging in cardiac CT as well as lung and bone imaging demand for high spatial resolution. Today, we see a transition of photon-counting detectors from experimental and research prototype setups into commercially available systems integrated in patient care. Moreover, with respect to CT technology and CT image formation, artificial intelligence is increasingly used in patient positioning, protocol adjustment, and image reconstruction, but also in image preprocessing or postprocessing. The aim of this article is to give an overview of the technical specifications of up-to-date available whole-body and dedicated CT systems, as well as hardware and software innovations for CT systems in the near future.
Collapse
|
10
|
Koetzier LR, Mastrodicasa D, Szczykutowicz TP, van der Werf NR, Wang AS, Sandfort V, van der Molen AJ, Fleischmann D, Willemink MJ. Deep Learning Image Reconstruction for CT: Technical Principles and Clinical Prospects. Radiology 2023; 306:e221257. [PMID: 36719287 PMCID: PMC9968777 DOI: 10.1148/radiol.221257] [Citation(s) in RCA: 98] [Impact Index Per Article: 49.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/27/2022] [Revised: 09/26/2022] [Accepted: 10/13/2022] [Indexed: 02/01/2023]
Abstract
Filtered back projection (FBP) has been the standard CT image reconstruction method for 4 decades. A simple, fast, and reliable technique, FBP has delivered high-quality images in several clinical applications. However, with faster and more advanced CT scanners, FBP has become increasingly obsolete. Higher image noise and more artifacts are especially noticeable in lower-dose CT imaging using FBP. This performance gap was partly addressed by model-based iterative reconstruction (MBIR). Yet, its "plastic" image appearance and long reconstruction times have limited widespread application. Hybrid iterative reconstruction partially addressed these limitations by blending FBP with MBIR and is currently the state-of-the-art reconstruction technique. In the past 5 years, deep learning reconstruction (DLR) techniques have become increasingly popular. DLR uses artificial intelligence to reconstruct high-quality images from lower-dose CT faster than MBIR. However, the performance of DLR algorithms relies on the quality of data used for model training. Higher-quality training data will become available with photon-counting CT scanners. At the same time, spectral data would greatly benefit from the computational abilities of DLR. This review presents an overview of the principles, technical approaches, and clinical applications of DLR, including metal artifact reduction algorithms. In addition, emerging applications and prospects are discussed.
Collapse
Affiliation(s)
| | | | - Timothy P. Szczykutowicz
- From the Department of Radiology (L.R.K., D.M., A.S.W., V.S., D.F.,
M.J.W.) and Stanford Cardiovascular Institute (D.M., D.F., M.J.W.), Stanford
University School of Medicine, 300 Pasteur Dr, Stanford, CA 94305-5105;
Department of Radiology, University of Wisconsin–Madison, School of
Medicine and Public Health, Madison, Wis (T.P.S.); Department of Radiology,
Erasmus Medical Center, Rotterdam, the Netherlands (N.R.v.d.W.); Clinical
Science Western Europe, Philips Healthcare, Best, the Netherlands (N.R.v.d.W.);
and Department of Radiology, Leiden University Medical Center, Leiden, the
Netherlands (A.J.v.d.M.)
| | - Niels R. van der Werf
- From the Department of Radiology (L.R.K., D.M., A.S.W., V.S., D.F.,
M.J.W.) and Stanford Cardiovascular Institute (D.M., D.F., M.J.W.), Stanford
University School of Medicine, 300 Pasteur Dr, Stanford, CA 94305-5105;
Department of Radiology, University of Wisconsin–Madison, School of
Medicine and Public Health, Madison, Wis (T.P.S.); Department of Radiology,
Erasmus Medical Center, Rotterdam, the Netherlands (N.R.v.d.W.); Clinical
Science Western Europe, Philips Healthcare, Best, the Netherlands (N.R.v.d.W.);
and Department of Radiology, Leiden University Medical Center, Leiden, the
Netherlands (A.J.v.d.M.)
| | - Adam S. Wang
- From the Department of Radiology (L.R.K., D.M., A.S.W., V.S., D.F.,
M.J.W.) and Stanford Cardiovascular Institute (D.M., D.F., M.J.W.), Stanford
University School of Medicine, 300 Pasteur Dr, Stanford, CA 94305-5105;
Department of Radiology, University of Wisconsin–Madison, School of
Medicine and Public Health, Madison, Wis (T.P.S.); Department of Radiology,
Erasmus Medical Center, Rotterdam, the Netherlands (N.R.v.d.W.); Clinical
Science Western Europe, Philips Healthcare, Best, the Netherlands (N.R.v.d.W.);
and Department of Radiology, Leiden University Medical Center, Leiden, the
Netherlands (A.J.v.d.M.)
| | - Veit Sandfort
- From the Department of Radiology (L.R.K., D.M., A.S.W., V.S., D.F.,
M.J.W.) and Stanford Cardiovascular Institute (D.M., D.F., M.J.W.), Stanford
University School of Medicine, 300 Pasteur Dr, Stanford, CA 94305-5105;
Department of Radiology, University of Wisconsin–Madison, School of
Medicine and Public Health, Madison, Wis (T.P.S.); Department of Radiology,
Erasmus Medical Center, Rotterdam, the Netherlands (N.R.v.d.W.); Clinical
Science Western Europe, Philips Healthcare, Best, the Netherlands (N.R.v.d.W.);
and Department of Radiology, Leiden University Medical Center, Leiden, the
Netherlands (A.J.v.d.M.)
| | - Aart J. van der Molen
- From the Department of Radiology (L.R.K., D.M., A.S.W., V.S., D.F.,
M.J.W.) and Stanford Cardiovascular Institute (D.M., D.F., M.J.W.), Stanford
University School of Medicine, 300 Pasteur Dr, Stanford, CA 94305-5105;
Department of Radiology, University of Wisconsin–Madison, School of
Medicine and Public Health, Madison, Wis (T.P.S.); Department of Radiology,
Erasmus Medical Center, Rotterdam, the Netherlands (N.R.v.d.W.); Clinical
Science Western Europe, Philips Healthcare, Best, the Netherlands (N.R.v.d.W.);
and Department of Radiology, Leiden University Medical Center, Leiden, the
Netherlands (A.J.v.d.M.)
| | - Dominik Fleischmann
- From the Department of Radiology (L.R.K., D.M., A.S.W., V.S., D.F.,
M.J.W.) and Stanford Cardiovascular Institute (D.M., D.F., M.J.W.), Stanford
University School of Medicine, 300 Pasteur Dr, Stanford, CA 94305-5105;
Department of Radiology, University of Wisconsin–Madison, School of
Medicine and Public Health, Madison, Wis (T.P.S.); Department of Radiology,
Erasmus Medical Center, Rotterdam, the Netherlands (N.R.v.d.W.); Clinical
Science Western Europe, Philips Healthcare, Best, the Netherlands (N.R.v.d.W.);
and Department of Radiology, Leiden University Medical Center, Leiden, the
Netherlands (A.J.v.d.M.)
| | - Martin J. Willemink
- From the Department of Radiology (L.R.K., D.M., A.S.W., V.S., D.F.,
M.J.W.) and Stanford Cardiovascular Institute (D.M., D.F., M.J.W.), Stanford
University School of Medicine, 300 Pasteur Dr, Stanford, CA 94305-5105;
Department of Radiology, University of Wisconsin–Madison, School of
Medicine and Public Health, Madison, Wis (T.P.S.); Department of Radiology,
Erasmus Medical Center, Rotterdam, the Netherlands (N.R.v.d.W.); Clinical
Science Western Europe, Philips Healthcare, Best, the Netherlands (N.R.v.d.W.);
and Department of Radiology, Leiden University Medical Center, Leiden, the
Netherlands (A.J.v.d.M.)
| |
Collapse
|