Zhao N, Du L, Lv C, Liang J, He L, Zhou Q. Accuracy analysis of robotic-assisted immediate implant placement: A retrospective case series. J Dent 2024; 146:105035. [PMID: 38734299 DOI: 10.1016/j.jdent.2024.105035] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/21/2023] [Revised: 04/19/2024] [Accepted: 04/30/2024] [Indexed: 05/13/2024] Open
Abstract
OBJECTIVES This study aimed to investigate the accuracy of a robotic computer-assisted implant surgery (r-CAIS) for immediate implant placement. METHODS Patients requiring immediate implant placement in the maxillary anterior region were enrolled for r-CAIS. Before surgery, the patients underwent a cone beam computed tomography (CBCT) scan with a positioning marker. Virtual implant placement position and drilling sequences were planned. Following spatial registration and calibration, the implants were placed with the robotic system under supervision. A postoperative CBCT was taken to control the actual implant positions. The DICOM data of the virtually planned and the actually placed implant were superimposed and registered through the accuracy verification software of the robotic system. The accuracy was calculated automatically. The deviation at the mesial-distal, labial-palatal, and apico-coronal directions were recorded. RESULTS Fifteen patients with 20 implants were included. No adverse surgical events or postoperative complications were reported. The global platform, apex, and angular deviation were 0.75 ± 0.20 mm (95 % CI: 0.65 to 0.84 mm), 0.70 ± 0.27 mm (95 % CI: 0.57 to 0.82 mm), and 1.17 ± 0.73° (95 % CI: 0.83 to 1.51°), respectively. Moreover, the vertical platform and apex deviation were 0.50 ± 0.31 mm, (95 % CI: 0.35 to 0.64 mm) and 0.48 ± 0.32 mm, (95 % CI: 0.33 to 0.63 mm), respectively. All the placed implant positions were further labial and apical than the planned ones, respectively. CONCLUSIONS High accuracy of immediate implant placement was achieved with the robotic system. CLINICAL SIGNIFICANCE Our study provided evidence to support the potential of the robotic system in implant placement, even in challenging scenarios.
Collapse
Affiliation(s)
- Ningbo Zhao
- Key Laboratory of Shaanxi Province for Craniofacial Precision Medicine Research, College of Stomatology, Xi'an Jiaotong University, PR China; Clinical Research Center of Shaanxi Province for Dental and Maxillofacial Disease, College of Stomatology, Xi'an Jiaotong University, PR China; Department of Implant Dentistry, College of Stomatology, Xi'an Jiaotong University, PR China
| | - Liangzhi Du
- Department of Implant Dentistry, College of Stomatology, Xi'an Jiaotong University, PR China
| | - Chengpeng Lv
- Department of Implant Dentistry, College of Stomatology, Xi'an Jiaotong University, PR China
| | - Jianfei Liang
- Key Laboratory of Shaanxi Province for Craniofacial Precision Medicine Research, College of Stomatology, Xi'an Jiaotong University, PR China; Clinical Research Center of Shaanxi Province for Dental and Maxillofacial Disease, College of Stomatology, Xi'an Jiaotong University, PR China; Department of Implant Dentistry, College of Stomatology, Xi'an Jiaotong University, PR China
| | - Longlong He
- Key Laboratory of Shaanxi Province for Craniofacial Precision Medicine Research, College of Stomatology, Xi'an Jiaotong University, PR China; Clinical Research Center of Shaanxi Province for Dental and Maxillofacial Disease, College of Stomatology, Xi'an Jiaotong University, PR China; Department of Implant Dentistry, College of Stomatology, Xi'an Jiaotong University, PR China.
| | - Qin Zhou
- Key Laboratory of Shaanxi Province for Craniofacial Precision Medicine Research, College of Stomatology, Xi'an Jiaotong University, PR China; Clinical Research Center of Shaanxi Province for Dental and Maxillofacial Disease, College of Stomatology, Xi'an Jiaotong University, PR China; Department of Implant Dentistry, College of Stomatology, Xi'an Jiaotong University, PR China.
| |
Collapse
|
2
|
Gonzalez-Passos T, Barros-Costa M, Oliveira ML, Freitas DQ. Influence of tube current and metal artifact reduction on the diagnosis of external cervical resorption in teeth adjacent to a dental implant in CBCT: an ex-vivo study. Clin Oral Investig 2024; 28:356. [PMID: 38834721 DOI: 10.1007/s00784-024-05750-y] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/03/2024] [Accepted: 05/27/2024] [Indexed: 06/06/2024]
Abstract
OBJECTIVES This ex-vivo study aimed to assess the influence of tube current (mA) and metal artifact reduction (MAR) on the diagnosis of early external cervical resorption (EECR) in cone-beam computed tomography (CBCT) in the presence of an adjacent dental implant. MATERIALS AND METHODS Twenty-three single-rooted teeth were sectioned longitudinally and EECR was induced using a spherical drill and 5% nitric acid in 10 teeth. Each tooth was positioned in the socket of the lower right canine of a dry human mandible and CBCT scans were acquired using 90 kVp, voxel of 0.085 mm, field of view of 5 x 5 cm, and varying tube current (4, 8 or 12 mA), MAR (enabled or disabled) and implant conditions (with a zirconia implant in the socket of the lower right first premolar or without). Five oral radiologists evaluated the presence of EECR in a 5-point scale and the diagnostic values (area under the receiver operating characteristic curve - AUC, sensitivity, and specificity) were compared using multi-way Analysis of Variance (α = 0.05). Kappa test assessed intra-/inter-evaluator agreement. RESULTS The tube current only influenced the AUC values in the presence of the implant and when MAR disabled; in this case, 8 mA showed lower values (p<0.007). MAR did not influence the diagnostic values (p>0.05). In general, the presence of an implant reduced the AUC values (p<0.0001); sensitivity values with 8 mA and MAR disabled, and specificity values with 4 mA and MAR enabled and 8 mA regardless MAR were also decreased (p<0.0001). CONCLUSIONS Variations in tube current and MAR were unable to improve EECR detection, which was impaired by the presence of an adjacent implant. CLINICAL RELEVANCE Increasing tube current or activating MAR tool does not improve EECR diagnosis, which is hampered by the artifacts generated by dental implants.
Collapse
Affiliation(s)
- Thamiles Gonzalez-Passos
- Department of Oral Diagnosis, Division of Oral Radiology, Piracicaba Dental School, University of Campinas, Piracicaba, SP, Brazil. Av. Limeira, 901, Zip Code13414903, Piracicaba, São Paulo, Brazil.
| | - Matheus Barros-Costa
- Department of Oral Diagnosis, Division of Oral Radiology, Piracicaba Dental School, University of Campinas, Piracicaba, SP, Brazil. Av. Limeira, 901, Zip Code13414903, Piracicaba, São Paulo, Brazil
| | - Matheus L Oliveira
- Department of Oral Diagnosis, Division of Oral Radiology, Piracicaba Dental School, University of Campinas, Piracicaba, SP, Brazil. Av. Limeira, 901, Zip Code13414903, Piracicaba, São Paulo, Brazil
| | - Deborah Queiroz Freitas
- Department of Oral Diagnosis, Division of Oral Radiology, Piracicaba Dental School, University of Campinas, Piracicaba, SP, Brazil. Av. Limeira, 901, Zip Code13414903, Piracicaba, São Paulo, Brazil
| |
Collapse
|
3
|
Capel CP, da Motta RJG, Pauwels R, Gaêta-Araujo H, Oliveira-Santos C, Tirapelli C. Effect of metal artefact reduction level on the assessment of dental implant positioning by cone-beam computed tomography. Dentomaxillofac Radiol 2024; 53:233-239. [PMID: 38466923 PMCID: PMC11056797 DOI: 10.1093/dmfr/twae008] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/05/2024] [Revised: 02/13/2024] [Accepted: 02/16/2024] [Indexed: 03/13/2024] Open
Abstract
OBJECTIVES This study evaluated the effect of metal artefact reduction (MAR) level and tube current on the assessment of dental implant positioning relative to the mandibular canal (MC) through cone-beam computed tomography (CBCT). METHODS Titanium dental implants were placed in dried mandibles at 0.5-mm superior to the MC (group 1/n = 8) and 0.5-mm inside the MC with perforation of the cortex (group 2/n = 10). CBCT scans were obtained with different levels of MAR (off, medium, and high) and 2 tube currents (4 and 8 mA). Four examiners analysed the images and scored the contact between the implant and the MC using a 5-point scale. Sensitivity, specificity, area under receiver operating characteristic curve (ROC), and frequency of scores were calculated. Data were compared with analysis of variance 2-way and Tukey's test and scores with Chi-square test. RESULTS Specificity and area under ROC curve decreased significantly when MAR level was high compared with MAR-medium and MAR-off. The frequency of score 3 (inconclusive) was the highest, and scores 1 and 5 (definitely no contact and definitely contact, respectively) were the lowest with MAR-high, regardless of the tube current. When MAR was off, there were higher frequencies of scores 1 and 5. CONCLUSIONS The level of MAR influences the assessment of the relationship between the dental implant and the MC. MAR-high led to lower diagnostic accuracy compared with MAR-medium and off. ADVANCES IN KNOWLEDGE This article shows that high level of MAR can interfere in the diagnostic of dental implant positioning relative to the MC, decreasing its accuracy.
Collapse
Affiliation(s)
- Camila Porto Capel
- Department of Dental Materials and Prosthodontics, Ribeirão Preto School of Dentistry, University of São Paulo, 14040-904, São Paulo, Brazil
| | - Raphael Jurca Gonçalves da Motta
- Department of Dental Materials and Prosthodontics, Ribeirão Preto School of Dentistry, University of São Paulo, 14040-904, São Paulo, Brazil
| | - Ruben Pauwels
- Department of Dentistry and Oral Health, Aarhus University, 8000 Aarhus, Denmark
- Department of Radiology, Faculty of Dentistry, Chulalongkorn University, 10330 Bangkok, Thailand
| | - Hugo Gaêta-Araujo
- Department of Stomatology, Public Health and Forensic Dentistry, Ribeirão Preto School of Dentistry, University of São Paulo, 14040-904, São Paulo, Brazil
| | - Christiano Oliveira-Santos
- Department of Diagnosis & Oral Health, University of Louisville, School of Dentistry, 40202-1701, Louisville, KY, United States
| | - Camila Tirapelli
- Department of Dental Materials and Prosthodontics, Ribeirão Preto School of Dentistry, University of São Paulo, 14040-904, São Paulo, Brazil
| |
Collapse
|
4
|
Han X, Wei D, Jiang X, Di P, Yi C, Lin Y. Digital registration versus cone-beam computed tomography for evaluating implant position: a prospective cohort study. BMC Oral Health 2024; 24:304. [PMID: 38438985 PMCID: PMC10913533 DOI: 10.1186/s12903-024-04088-x] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/04/2023] [Accepted: 02/29/2024] [Indexed: 03/06/2024] Open
Abstract
BACKGROUND Postoperative cone-beam computed tomography (CBCT) examination is considered a reliable method for clinicians to assess the positions of implants. Nevertheless, CBCT has drawbacks involving radiation exposure and high costs. Moreover, the image quality can be affected by artifacts. Recently, some literature has mentioned a digital registration method (DRM) as an alternative to CBCT for evaluating implant positions. The aim of this clinical study was to verify the accuracy of the DRM compared to CBCT scans in postoperative implant positioning. MATERIALS AND METHODS A total of 36 patients who received anterior maxillary implants were included in this clinical study, involving a total of 48 implants. The study included 24 patients in the single implant group and 12 patients in the dual implant group. The postoperative three-dimensional (3D) positions of implants were obtained using both CBCT and DRM. The DRM included three main steps. Firstly, the postoperative 3D data of the dentition and intraoral scan body (ISB) was obtained through the intraoral scan (IOS). Secondly, a virtual model named registration unit which comprised an implant replica and a matching ISB was created with the help of a lab scanner and reverse engineering software. Thirdly, by superimposing the registration unit and IOS data, the postoperative position of the implant was determined. The accuracy of DRM was evaluated by calculating the Root Mean Square (RMS) values after superimposing the implant positions obtained from DRM with those from postoperative CBCT. The accuracy of DRM was compared between the single implant group and the dual implant group using independent sample t-tests. The superimposition deviations of CBCT and IOS were also evaluated. RESULTS The overall mean RMS was 0.29 ± 0.05 mm. The mean RMS was 0.30 ± 0.03 mm in the single implant group and 0.29 ± 0.06 mm in the dual implant group, with no significant difference (p = 0.27). The overall registration accuracy of the IOS and CBCT data ranged from 0.14 ± 0.05 mm to 0.21 ± 0.08 mm. CONCLUSION In comparison with the 3D implant positions obtained by CBCT, the implant positions located by the DRM showed clinically acceptable deviation ranges. This method can be used in single and dual implant treatments to assess the implant positions.
Collapse
Affiliation(s)
- Xinrui Han
- Department of Oral Implantology, Peking University School and Hospital of Stomatology & National Clinical Research Center for Oral Diseases & National Engineering Research Center of Oral Biomaterials and Digital Medical Devices & Beijing Key Laboratory of Digital Stomatology, 22 Zhongguancun South Avenue, Haidian District, Beijing, 100081, PR China
| | - Donghao Wei
- Department of Oral Implantology, Peking University School and Hospital of Stomatology & National Clinical Research Center for Oral Diseases & National Engineering Research Center of Oral Biomaterials and Digital Medical Devices & Beijing Key Laboratory of Digital Stomatology, 22 Zhongguancun South Avenue, Haidian District, Beijing, 100081, PR China
| | - Xi Jiang
- Department of Oral Implantology, Peking University School and Hospital of Stomatology & National Clinical Research Center for Oral Diseases & National Engineering Research Center of Oral Biomaterials and Digital Medical Devices & Beijing Key Laboratory of Digital Stomatology, 22 Zhongguancun South Avenue, Haidian District, Beijing, 100081, PR China
| | - Ping Di
- Department of Oral Implantology, Peking University School and Hospital of Stomatology & National Clinical Research Center for Oral Diseases & National Engineering Research Center of Oral Biomaterials and Digital Medical Devices & Beijing Key Laboratory of Digital Stomatology, 22 Zhongguancun South Avenue, Haidian District, Beijing, 100081, PR China
| | - Chun Yi
- Department of Oral Implantology, Peking University School and Hospital of Stomatology & National Clinical Research Center for Oral Diseases & National Engineering Research Center of Oral Biomaterials and Digital Medical Devices & Beijing Key Laboratory of Digital Stomatology, 22 Zhongguancun South Avenue, Haidian District, Beijing, 100081, PR China.
| | - Ye Lin
- Department of Oral Implantology, Peking University School and Hospital of Stomatology & National Clinical Research Center for Oral Diseases & National Engineering Research Center of Oral Biomaterials and Digital Medical Devices & Beijing Key Laboratory of Digital Stomatology, 22 Zhongguancun South Avenue, Haidian District, Beijing, 100081, PR China.
| |
Collapse
|
5
|
Asnaashari M, Sadeghipour M, Bahrani Z, Valizadeh S, Moshfeghi M. The Effect of Changes in the Angular Position of Implants on Metal Artifact Reduction in Cone-Beam Computed Tomography Images: A Scoping Review. Radiol Res Pract 2023; 2023:5539719. [PMID: 37554657 PMCID: PMC10406552 DOI: 10.1155/2023/5539719] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/04/2023] [Revised: 07/07/2023] [Accepted: 07/20/2023] [Indexed: 08/10/2023] Open
Abstract
OBJECTIVE Dental implant artifacts can compromise the quality of cone-beam computed tomography (CBCT) scans and challenge radiographic detection in surrounding regions. This literature review was conducted to examine the impact of implant angle modification on reducing metal artifacts in CBCT scans. MATERIALS AND METHODS A scoping review of literature was carried out in PubMed, Embase, Scopus, and Cochrane databases. RESULTS Different spatial planes, including alpha, beta, gamma, and phi, along with 0°, 5.2°, 9.8°, 14.5°, 15°, 30°, 45°, 60°, 75°, and 90° angles were studied. Changes in the angular position of implants may reduce metal artifacts and improve the quality of CBCT scans. CONCLUSIONS Rotating implants within the alpha plane and angling them at 90° in the alpha plane enables reducing dental implant artifacts.
Collapse
Affiliation(s)
- Maedeh Asnaashari
- School of Dentistry, Shahid Beheshti University of Medical Sciences, Tehran, Iran
| | - Maryam Sadeghipour
- Department of Community Oral Health, School of Dentistry, Shahid Beheshti University of Medical Sciences, Tehran, Iran
| | - Zeinab Bahrani
- Department of Prosthodontics, School of Dentistry, Shahid Beheshti University of Medical Sciences, Tehran, Iran
| | - Solmaz Valizadeh
- Department of Oral and Maxillofacial Radiology, School of Dentistry, Shahid Beheshti University of Medical Sciences, Tehran, Iran
| | - Mahkameh Moshfeghi
- Department of Oral and Maxillofacial Radiology, School of Dentistry, Shahid Beheshti University of Medical Sciences, Tehran, Iran
| |
Collapse
|
6
|
de Freitas BN, da Motta RJG, Pauwels R, Oliveira-Santos C, Tirapelli C. Influence of metal artefact reduction on the diagnosis of contact between implant and mandibular canal in cone beam computed tomography: An ex-vivo study. Clin Oral Implants Res 2023; 34:741-750. [PMID: 37246310 DOI: 10.1111/clr.14100] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/05/2023] [Revised: 04/23/2023] [Accepted: 05/12/2023] [Indexed: 05/30/2023]
Abstract
OBJECTIVE To evaluate the influence of metal artefact reduction (MAR) in the diagnosis of dental implant contact with the mandibular canal (MC) using cone beam computed tomography (CBCT). METHODS Dental implants were installed with surgical guides in the posterior hemiarches of 10 dry human mandibles: 0.5 mm above to the MC cortex (G1/n = 8) and 0.5 mm inside the MC (G2/n = 10). The experimental set-up was scanned with two CBCT equipment using 85 kV and 90 kV, MAR ON or OFF, and different tube currents (4 mA, 8 mA and 10 mA). Two dentomaxillofacial radiologists (DMFRs) and two dentists (DDS) scored the relation between the dental implant and MC. Descriptive statistics were used to observe the absolute frequency of scores. Sensitivity, specificity and accuracy were calculated considering the known relation between the dental implant and the MC interior. McNemar's test (α = .05) was applied to compare the diagnostic efficacy of MAR ON versus MAR OFF. RESULTS Overall specificity was higher than sensitivity for both DDS and DMFR (97% vs. 50% and 92.0% vs. 78.0% respectively). There was a significant effect of MAR (p = .031) for DMFR in the case of contact between the dental implant with the MC interior, in which sensitivity decreased with MAR activation from 90% to 40%. DMFR observers showed a better diagnostic performance compared with the DDS observers (accuracy of 84.0% and 71.0%, respectively). CONCLUSIONS Due to the limited efficacy of MAR, it should not be used when conducting CBCT scans for the evaluation of contact between the implant and the mandibular canal.
Collapse
Affiliation(s)
- Bruna Neves de Freitas
- Department of Dental Materials and Prosthodontics, School of Dentistry of Ribeirão Preto, University of São Paulo, São Paulo, Brazil
| | - Raphael Jurca Gonçalves da Motta
- Department of Dental Materials and Prosthodontics, School of Dentistry of Ribeirão Preto, University of São Paulo, São Paulo, Brazil
| | - Ruben Pauwels
- Department of Dentistry and Oral Health, Aarhus University, Aarhus, Denmark
- Department of Radiology, Faculty of Dentistry, Chulalongkorn University, Bangkok, Thailand
| | - Christiano Oliveira-Santos
- Department of Diagnosis & Oral Health, University of Louisville School of Dentistry, Louisville, Kentucky, USA
| | - Camila Tirapelli
- Department of Dental Materials and Prosthodontics, School of Dentistry of Ribeirão Preto, University of São Paulo, São Paulo, Brazil
| |
Collapse
|
7
|
Li S, Yi C, Yu Z, Wu A, Zhang Y, Lin Y. Accuracy assessment of implant placement with versus without a CAD/CAM surgical guide by novices versus specialists via the digital registration method: an in vitro randomized crossover study. BMC Oral Health 2023; 23:426. [PMID: 37370027 PMCID: PMC10294323 DOI: 10.1186/s12903-023-03116-6] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/18/2023] [Accepted: 06/07/2023] [Indexed: 06/29/2023] Open
Abstract
BACKGROUND Many studies demonstrated that surgical guides might reduce discrepancies compared with freehand implant placement. This randomized crossover study aimed to assess the effects of approaches, practitioners' experience and learning sequences on the accuracy of single tooth implantation via digital registration method. No similar study was found. METHODS This in vitro randomized crossover study enrolled 60 novice students (Group S) and 10 experienced instructors (Group I). Sixty students were randomly and evenly assigned to two groups (Group SA and SB). In Group SA, 30 students first performed single molar implant on a simulation model freehand (Group SAFH), and then with a CAD/CAM surgical guide (Group SASG). In Group SB, another 30 students first performed guided (Group SBSG) and then freehand (Group SBFH). Ten instructors were also divided into Group IAFH/IASG (n = 5) and IBSG/IBFH (n = 5) following the same rules. The accuracy of implant placement was assessed by the coronal and apical distance (mm) and angular (°) deviations using the digital registration method. T tests and nonparametric tests were used to compare the results among different groups of approaches, experience and sequences. RESULTS For students, the coronal and apical distance and the angular deviations were significantly lower in surgical guide group than freehand group in total and in learning freehand first subgroup, but for learning surgical guide first subgroup the apical distance deviation showed no significant difference between two approaches. For students, the angular deviation of freehand group was significantly lower in learning surgical guide first group than learning freehand first group. For instructors, the coronal and apical distance and angular deviations showed no significant difference between two approaches and two sequences. For freehand approach, the coronal and apical distance and the angular deviations were significantly higher in student group than instructor group, while not significantly different between two groups for surgical guide approach. CONCLUSIONS For novices, using a surgical guide for the first implant placement may reduce the potential deviations compared with freehand surgery, and may reach a comparable accuracy with that of specialists. For simple single molar implantation, the surgical guide may not be significantly helpful for experienced specialists.
Collapse
Affiliation(s)
- Sha Li
- Department of Oral Implantology, Peking University School and Hospital of Stomatology & National Clinical Research Center for Oral Diseases & National Engineering Research Center of Oral Biomaterials and Digital Medical Devices & Beijing Key Laboratory of Digital Stomatology, 22 Zhongguancun South Avenue, Haidian District, 100081, Beijing, P. R. China
| | - Chun Yi
- Department of Oral Implantology, Peking University School and Hospital of Stomatology & National Clinical Research Center for Oral Diseases & National Engineering Research Center of Oral Biomaterials and Digital Medical Devices & Beijing Key Laboratory of Digital Stomatology, 22 Zhongguancun South Avenue, Haidian District, 100081, Beijing, P. R. China
| | - Ziyang Yu
- Department of Oral Implantology, Peking University School and Hospital of Stomatology Center of Digital, Dentistry, Peking University School and Hospital of Stomatology & National Clinical Research Center for Oral Diseases & National Engineering Research Center of Oral Biomaterials and Digital Medical Devices & Beijing Key Laboratory of Digital Stomatology, Beijing, P. R. China
| | - Aozhou Wu
- Department of Epidemiology, Johns Hopkins Bloomberg School of Public Health, Baltimore, MD, USA
| | - Yu Zhang
- Department of Oral Implantology, Peking University School and Hospital of Stomatology & National Clinical Research Center for Oral Diseases & National Engineering Research Center of Oral Biomaterials and Digital Medical Devices & Beijing Key Laboratory of Digital Stomatology, 22 Zhongguancun South Avenue, Haidian District, 100081, Beijing, P. R. China.
| | - Ye Lin
- Department of Oral Implantology, Peking University School and Hospital of Stomatology & National Clinical Research Center for Oral Diseases & National Engineering Research Center of Oral Biomaterials and Digital Medical Devices & Beijing Key Laboratory of Digital Stomatology, 22 Zhongguancun South Avenue, Haidian District, 100081, Beijing, P. R. China.
| |
Collapse
|
8
|
Goodarzi Pour D, Emami Meybodi E, Sodagar K, Emami Meybodi ZA, Safari S. Effect of metal artifact removal modes on the accuracy of linear measurement around titanium implants by applying different voltages: an original article. BMC Med Imaging 2023; 23:74. [PMID: 37277737 DOI: 10.1186/s12880-023-01025-2] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/25/2022] [Accepted: 05/23/2023] [Indexed: 06/07/2023] Open
Abstract
BACKGROUND This study aims to evaluate the effects of the artifact removal algorithm on linear measurements of the buccal cortical plate by altering the voltage. METHODS Ten titanium fixtures were inserted at the site of central, lateral, canine, premolars and molars of dry human mandibles. Vertical height of buccal plate was measured using a digital caliper as a gold standard. Mandibles were scanned with 54 and 58 kVp. Other parameters were constant. Images were reconstructed with none, low, medium and high artifact removal modes. Two Oromaxillofacial radiologists evaluated and measured the buccal plate height using Romexis software. Statistical package for the social sciences (SPSS) version 24 was used for data analysis. RESULTS In medium and high modes, the difference between 54 and 58 kVp was significant (p < 0.001). No significance was noted by using low ARM (artifact removal mode) at the 54 kVp and 58 kVp. CONCLUSION Using artifact removal in low voltage decreases the accuracy of linear measurement and buccal crest visibility. By using high voltage, artifact removal would have no significant effect on accuracy of linear measurements.
Collapse
Affiliation(s)
- Daryoush Goodarzi Pour
- Department of Oral and Maxillofacial Radiology, School of Dentistry, Tehran University of Medical Sciences, Tehran, Iran
| | | | - Kosar Sodagar
- School of Dentistry, Tehran University of Medical Sciences, Tehran, Iran
| | | | - Sanaz Safari
- School of Dentistry, Tehran University of Medical Sciences, Tehran, Iran
| |
Collapse
|
9
|
Khurana S, Parasher P, Creanga AG, Geha H. Effect of Mandible Phantom Inclination in the Axial Plane on Image Quality in the Presence of Implant Using Cone-Beam Computer Tomography. Cureus 2023; 15:e36630. [PMID: 37155440 PMCID: PMC10122839 DOI: 10.7759/cureus.36630] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Accepted: 03/24/2023] [Indexed: 05/10/2023] Open
Abstract
Purpose To assess the effect of 30° phantom inclination on image quality in the presence of an implant using cone-beam computed tomography (CBCT). Materials and methods Three series of eight scans were taken and categorized by a range of 87-90 kVp and 7.1 mA, and 8 mA. For the first CBCT series, the phantom was placed on a flat plane. For the second series, the phantom was inclined at 30° in the axial plane. For the third series, inclined scans were re-oriented and included for statistics. In total, 24 scans were used for statistics. i.e., eight scans at three different planes (flat plane, inclined plane, and re-oriented inclined plane). All the images were analyzed for artifact and contrast-to-noise ratio (CNR) on ImageJ software. Results The inclination of the dry human mandible phantom by 30° reduces the artifact (p <0.05). However, the CNR was not affected by the phantom inclination. Conclusion The appropriate inclination of the head can significantly reduce the metal artifact in the presence of implants and thus improve the CBCT image quality for post-operative follow-up.
Collapse
Affiliation(s)
- Sonam Khurana
- Oral Pathology, Radiology, and Medicine, New York University College of Dentistry, New York City, USA
| | - Pranav Parasher
- Diagnostic Radiology, Rutgers School of Dental Medicine, Newark, USA
| | - Adriana G Creanga
- Oral and Maxillofacial Radiology, Rutgers School of Dental Medicine, Newark, USA
| | - Hassem Geha
- Oral and Maxillofacial Radiology, University of Texas Health Science Center at San Antonio, San Antonio, USA
| |
Collapse
|
10
|
Digital versus radiographic accuracy evaluation of guided implant surgery: an in vitro study. BMC Oral Health 2022; 22:540. [DOI: 10.1186/s12903-022-02585-5] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/03/2022] [Accepted: 11/11/2022] [Indexed: 11/25/2022] Open
Abstract
Abstract
Background
Cone-beam computed tomography (CBCT) is the most widely used method for postsurgical evaluation of the accuracy of guided implant surgery. However, the disadvantages of CBCT include radiation exposure, artifacts caused by metal implants, and high cost. Few studies have introduced a digital registration method to replace CBCT for evaluating the accuracy of guided surgery. The purpose of this study was to compare digital registration to conventional CBCT in terms of the capacity to evaluate the implant positioning accuracy of guided surgery.
Materials and methods
This in vitro study included 40 acrylic resin models with posterior single mandibular tooth loss. Guided surgery software was used to determine the optimal implant position; 40 tooth-supported fully guided drilling templates were designed and milled accordingly. After the guided surgery, the accuracies of the surgical templates were evaluated by conventional CBCT and digital registration. For evaluation by conventional CBCT, postsurgical CBCT scans of the resin models were performed. The CBCT data were reconstructed and superimposed on the implant planning data. For digital registration, we constructed a virtual registration unit that consisted of an implant replica and a scan body. Next, we obtained postsurgical optical scans of resin models with the scan body. The postsurgical implant position was identified by superimposition of the registration unit and optical scan data. The implant planning data and postsurgical implant position data were superimposed; deviations were reported in terms of distance for implant entry/apex point and in terms of angle for the implant axis. Interclass correlation coefficients (ICCs) and Bland–Altman plots were used to analyze the agreement between the two evaluation methods.
Results
The ICCs between the two methods were 0.986, 0.993, and 0.968 for the entry point, apex point, and angle, respectively; all were significantly greater than 0.75 (p < 0.001). Bland–Altman plots showed that the 95% limits of agreement of the differences were − 0.144 to + 0.081 mm, − 0.135 to + 0.147 mm, and − 0.451° to + 0.729° for the entry point, apex point, and angle, respectively; all values were within the maximum tolerated difference.
Conclusion
Conventional CBCT and digital registration showed good agreement in terms of evaluating the accuracy of implant positioning using tooth-supported surgical templates.
Collapse
|
11
|
Shokri A, Vafaee F, Haghighat L, Shahabi S, Farhadian M, Jamalpour MR. Comparison of the amount of artifacts induced by zirconium and titanium implants in cone-beam computed tomography images. BMC Med Imaging 2022; 22:156. [PMID: 36057551 PMCID: PMC9440550 DOI: 10.1186/s12880-022-00884-5] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/30/2022] [Accepted: 08/29/2022] [Indexed: 11/18/2022] Open
Abstract
Background This study aimed to compare the amount of artifacts induced by the titanium and zirconium implants on cone-beam computed tomography (CBCT) and assess the effect of different exposure settings on the image quality for both materials.
Methods In this experimental study, 30 zirconium and 30 titanium implants were placed in bovine rib bone blocks. CBCT images were taken in two different fields of view (FOV: 4 × 6 cm2 and 6 × 8 cm2) and at two resolutions (133 µ and 200 µ voxel size). Subsequently, two observers assessed the images and detected the amount of artifacts around the implants through gray values. Data were analyzed by paired t test and independent t test using SPSS 21 and the 0.05 significance level. Results The results showed that titanium implants caused lower amounts of artifacts than zirconium implants, which was statistically significant (P < 0.001). The larger FOV (6 × 8 cm2) resulted in a lower amount of artifacts in both groups, although the results were only statistically significant in the zirconium group (P < 0.001). The amount of artifacts was increased when using the 133 µ voxel size in both groups, which was only significant in the zirconium group (P < 0.001). Conclusion Our results suggest that zirconium implants induce higher amounts of artifacts than titanium ones. We also concluded that the artifacts could be minimized using the larger FOV and voxel size.
Collapse
Affiliation(s)
- Abbas Shokri
- Department of Oral and Maxillofacial Radiology, Dental Implants Research Center, Hamadan University of Medical Sciences, Hamadan, Iran
| | - Fariborz Vafaee
- Department of Prosthodontics, Dental Implants Research Center, Hamadan University of Medical Sciences, Hamadan, Iran
| | | | - Shiva Shahabi
- Dental Implants Research Center, Hamadan University of Medical Sciences, Hamadan, Iran
| | - Maryam Farhadian
- Department of Biostatistics, School of Public Health and Research Center for Health Sciences, Hamadan University of Medical Sciences, Hamadan, Iran
| | - Mohammad Reza Jamalpour
- Department of Oral and Maxillofacial Surgery, Dental Implants Research Center, Hamadan University of Medical Sciences, Shaheed Fahmideh Avenue, Hamadan, 6517838636, Iran.
| |
Collapse
|
12
|
Moshfeghi M, Safi Y, Różyło-Kalinowska I, Gandomi S. Does the size of an object containing dental implant affect the expression of artifacts in cone beam computed tomography imaging? Head Face Med 2022; 18:20. [PMID: 35765076 PMCID: PMC9241278 DOI: 10.1186/s13005-022-00326-1] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/11/2022] [Accepted: 06/13/2022] [Indexed: 11/29/2022] Open
Abstract
Background Artifacts fault image quality but handling several factors can affect it. This study was conducted to investigate the effect of object size on artifacts in cone-beam computed tomography systems. Methods Five phantoms, each containing a titanium implant in a sheep bone block, were fabricated of various sizes ranging from XS to XL: The M phantom was the same size as the device’s field of view (FOV). The L and XL phantoms were 20 and 40% larger than the FOV while the S and XS phantoms were 20 and 40% smaller than FOV, respectively. Ballistic gelatin was used to fill the phantoms. Phantoms were scanned by NewTom VGI and HDXWill Q-FACE. The mean and standard deviation (SD) of gray values in each 120 ROI was obtained by OnDemand software. The contrast to noise ratio (CNR) was also calculated. Results The gray value in S and M phantoms were more homogenous. The lowest SD value (10.20) was found in S phantom. The highest value for SD (125.16) was observed in XL phantom. The lowest (4.47) and highest (9.92) CNR were obtained in XL and S phantoms, respectively. HDXWill Q-FACE recorded a higher SD and a lower CNR than NewTom VGI (P < 0.05). Conclusion Object dimensions of the FOV size or up to 20% smaller provided better image quality. Since the dimensions of soft tissue in most patients are larger than the selective FOV, it is recommended that in CBCT artifacts studies, an object with dimensions closer to the patient’s dimensions be used to better relate the results with the clinical condition, because the sample dimensions affect the amount of artifacts.
Collapse
Affiliation(s)
- Mahkameh Moshfeghi
- Department of Oral and Maxillofacial Radiology, School of Dentistry, Shahid Beheshti University of Medical Sciences, Tehran, Iran
| | - Yaser Safi
- Department of Oral and Maxillofacial Radiology, School of Dentistry, Shahid Beheshti University of Medical Sciences, Tehran, Iran
| | - Ingrid Różyło-Kalinowska
- Department of Dental and Maxillofacial Radiodiagnostics, Medical University of Lublin, Lublin, Poland
| | - Shiva Gandomi
- Department of Oral and Maxillofacial Radiology, School of Dentistry, Ahvaz Jundishapur University of Medical Sciences, Ahvaz, Iran.
| |
Collapse
|
13
|
In Vitro Quantitative Evaluation of Postprocessing Filter for Metal Artifact Reduction in Cone Beam Computed Tomography Images of Titanium and Zirconium Dioxide Implants. BIOMED RESEARCH INTERNATIONAL 2022; 2022:1362473. [PMID: 35295958 PMCID: PMC8920685 DOI: 10.1155/2022/1362473] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 11/02/2021] [Revised: 01/25/2022] [Accepted: 02/16/2022] [Indexed: 11/17/2022]
Abstract
Objective To evaluate a postprocessing filter of a new imaging-processing software for analysis of metal artifact reduction. Methods Eight artificial edentulous mandibles (phantoms), where titanium and zirconium dioxide implants had been installed in four different regions (i.e., incisors, canine, premolars, and molars). CBCT volume was acquired, and then, four types of filters were applied to the images: BAR filter and Multi-CDT NR filter (e-Vol DX) and Sharpening Filters 1x and 2x (OnDemand). Artifact was assessed by measuring the standard deviation (SD) of the gray values of filtered and unfiltered images. The comparison between implant material, teeth, and filters was performed by using ANOVA, whereas multiple comparisons were performed by using Bonferroni's test. The level of significance adopted was 5%. Results The results showing higher SD values, which suggests a worse image, were obtained with titanium implants compared to zirconium dioxide ones. With regard to the four filters used, it can be seen that the lowest SD values were obtained with BAR and Multi-CDT NR filters and the highest with Sharpening Filters 1x and 2x, with no statistical difference between them, except regarding the molar region in titanium implants. Conclusion The highest SD values were seen in zirconium dioxide implants, mainly in the region of anterior teeth. The BAR filter was found to be the most effective as its SD value decreased significantly, indicating that the image quality was improved.
Collapse
|
14
|
Hu KF, Lin SW, Lin YC, Jeng JH, Huang YT, Liu PF, Tseng CJ, Chou YH. Using Cone-Beam Computed Tomography to Assess Changes in Alveolar Bone Width around Dental Implants at Native and Reconstructed Bone Sites: A Retrospective Cohort Study. J Pers Med 2021; 11:jpm11101011. [PMID: 34683152 PMCID: PMC8537892 DOI: 10.3390/jpm11101011] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/19/2021] [Revised: 10/03/2021] [Accepted: 10/04/2021] [Indexed: 12/13/2022] Open
Abstract
The aim of this study was to use a cone-beam computed tomography (CBCT) to assess changes in alveolar bone width around dental implants at native and reconstructed bone sites before and after implant surgery. A total of 99 implant sites from 54 patients with at least two CBCT scans before and after implant surgery during 2010–2019 were assessed in this study. Demographic data, dental treatments and CBCT scans were collected. Horizontal alveolar bone widths around implants at three levels (subcrestal width 1 mm (CW1), subcrestal width 4 mm (CW4), and subcrestal width 7 mm (CW7)) were measured. A p-value of < 0.05 indicated statistically significant differences. The initial bone widths (mean ± standard deviation (SD)) at CW1, CW4, and CW7 were 6.98 ± 2.24, 9.97 ± 2.64, and 11.33 ± 3.00 mm, respectively, and the postsurgery widths were 6.83 ± 2.02, 9.58 ± 2.55, and 11.19 ± 2.90 mm, respectively. The change in bone width was 0.15 ± 1.74 mm at CW1, 0.39 ± 1.12 mm at CW4 (p = 0.0008), and 0.14 ± 1.05 mm at CW7. A statistically significant change in bone width was observed at only the CW4 level. Compared with those at the native bone sites, the changes in bone width around implants at reconstructed sites did not differ significantly. A significant alveolar bone width resorption was found only at the middle third on CBCT scans. No significant changes in bone width around implants were detected between native and reconstructed bone sites.
Collapse
Affiliation(s)
- Kai-Fang Hu
- Institute of Clinical Medicine, National Yang Ming Chiao Tung University, Taipei 112, Taiwan;
- Department of Dentistry, Division of Periodontics, Kaohsiung Medical University Hospital, Kaohsiung 80708, Taiwan
| | - Szu-Wei Lin
- School of Dentistry, College of Dental Medicine, Kaohsiung Medical University, Kaohsiung 807378, Taiwan; (S.-W.L.); (Y.-C.L.); (J.-H.J.)
| | - Ying-Chu Lin
- School of Dentistry, College of Dental Medicine, Kaohsiung Medical University, Kaohsiung 807378, Taiwan; (S.-W.L.); (Y.-C.L.); (J.-H.J.)
| | - Jiiang-Huei Jeng
- School of Dentistry, College of Dental Medicine, Kaohsiung Medical University, Kaohsiung 807378, Taiwan; (S.-W.L.); (Y.-C.L.); (J.-H.J.)
- Department of Dentistry, National Taiwan University Hospital and School of Dentistry, National Taiwan University Medical College, Taipei 106216, Taiwan
- Department of Dentistry, Kaohsiung Medical University Hospital, Kaohsiung 80708, Taiwan
| | - Yu-Ting Huang
- Department of Medical Research, Division of Medical Statistics and Bioinformatics, Kaohsiung Medical University Hospital, Kaohsiung Medical University, Kaohsiung 80708, Taiwan;
| | - Pei-Feng Liu
- Department of Biomedical Science and Environmental Biology, Kaohsiung Medical University, Kaohsiung 807378, Taiwan;
- Department of Medical Research, Kaohsiung Medical University Hospital, Kaohsiung 80708, Taiwan
- Center for Cancer Research, Kaohsiung Medical University, Kaohsiung 807378, Taiwan
- Institute of Biomedical Sciences, National Sun Yat-sen University, Kaohsiung 804201, Taiwan
| | - Ching-Jiunn Tseng
- Institute of Clinical Medicine, National Yang Ming Chiao Tung University, Taipei 112, Taiwan;
- Department of Medical education and Research, Kaohsiung Veterans General Hospital, Kaohsiung 813779, Taiwan
- Department of Medical Research, China Medical University Hospital, China Medical University, Taichung 40402, Taiwan
- Correspondence: (C.-J.T.); (Y.-H.C.); Tel.: +886-975-581-557 (C.-J.T.); +886-7-3121101-7004 (Y.-H.C.)
| | - Yu-Hsiang Chou
- Department of Dentistry, Division of Periodontics, Kaohsiung Medical University Hospital, Kaohsiung 80708, Taiwan
- School of Dentistry, College of Dental Medicine, Kaohsiung Medical University, Kaohsiung 807378, Taiwan; (S.-W.L.); (Y.-C.L.); (J.-H.J.)
- Correspondence: (C.-J.T.); (Y.-H.C.); Tel.: +886-975-581-557 (C.-J.T.); +886-7-3121101-7004 (Y.-H.C.)
| |
Collapse
|
15
|
Salemi F, Jamalpour MR, Eskandarloo A, Tapak L, Rahimi N. Efficacy of Metal Artifact Reduction Algorithm of Cone-Beam Computed Tomography for Detection of Fenestration and Dehiscence around Dental Implants. J Biomed Phys Eng 2021; 11:305-314. [PMID: 34189119 PMCID: PMC8236107 DOI: 10.31661/jbpe.v0i0.2102-1284] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/16/2021] [Accepted: 04/02/2021] [Indexed: 11/30/2022]
Abstract
Background: Beam hardening and scattering artifacts from high-density objects such as dental implants adversely affect the image quality and subsequently the detection of fenestration or dehiscence around dental implants. Objective: This study aimed to assess the efficacy of metal artifact reduction (MAR) algorithm of two cone-beam computed tomography (CBCT) systems for detection of peri-implant fenestration and dehiscence. Material and Methods: In this experimental study, thirty-six titanium implants were placed in bone blocks of bovine ribs. Fenestration and dehiscence were created in the buccal bone around implants.
CBCT images were obtained using Cranex 3D and ProMax 3D CBCT systems with and without MAR algorithm. Two experienced radiologists observed the images. Data were analyzed using SPSS software.
The Kappa coefficient of agreement, the area under the receiver operating characteristic (ROC) curve, sensitivity, specificity, and accuracy of different imaging modalities were calculated and analyzed. Results: In both CBCT systems, the use of MAR algorithm decreased the area under the ROC curve and subsequently the diagnostic accuracy for the detection of fenestration and dehiscence.
The sensitivity, specificity and accuracy of both CBCT systems were higher in absence of the MAR algorithm. The specificity of ProMax 3D for detection of fenestration was equal with/without the MAR algorithm. Conclusion: Although CBCT is suitable for detection of peri-implant defects, the application of the MAR algorithm does not enhance the detection of peri-implant fenestration and dehiscence.
Collapse
Affiliation(s)
- Fatemeh Salemi
- PhD, Department of Oral & Maxillofacial Radiology, School of Dentistry, Hamadan university of Medical Science, Hamadan, Iran
| | - Mohamad Reza Jamalpour
- MScD, Department of Oral and Maxillofacial Surgery, Dental Implants Research Center, School of Dentistry, Hamadan university of Medical Science. Hamadan, Iran
| | - Amir Eskandarloo
- PhD, Department of Oral & Maxillofacial Radiology, School of Dentistry, Hamadan university of Medical Science, Hamadan, Iran
| | - Leili Tapak
- PhD, Department of Biostatistics, School of Health Modeling of Noncommunicable Diseases Research Center, Health Sciences & Technology Research Institute, Hamadan University of Medical Sciences, Hamadan, Iran
| | - Narges Rahimi
- DMD, General Dentist, Hamadan University of Medical Sciences, Hamadan, Iran
| |
Collapse
|
16
|
Min CK, Kim KA. Quantitative analysis of metal artefacts of dental implant in CBCT image by correlation analysis to micro-CT: A microstructural study. Dentomaxillofac Radiol 2021; 50:20200365. [PMID: 33002369 DOI: 10.1259/dmfr.20200365] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/20/2023] Open
Abstract
OBJECTIVES Quantification of dental implant metal artefacts in CBCT images using correlation analysis of trabecular microstructural parameters from CBCT and micro-CT, and analysis of the effect of varying the angular position of the subject. METHODS Polyurethane synthetic bone blocks were first scanned without implants by micro-CT and CBCT. Two dental implants were then placed parallel in the bone blocks and these specimens were scanned by CBCT with different alpha angles. Three volumes of interest (VOI) were set for further analysis. Six microstructural parameters were measured: trabecular thickness (TbTh), trabecular spacing (ThSp), bone volume per total volume (BV/TV), bone surface per total volume (BS/TV), connectivity density (CD) andfractal dimension (FD). Micro-CT measurements were used as a gold standard for CBCT. Spearman correlation coefficients for each microstructural parameter from CBCT and micro-CT were calculated and compared using Steiger's Z test. RESULTS Without the implants, in VOI1, the Spearman correlation coefficients of TbTh, TbSp, BV/TV, BS/TV, CD and FD were 0.599, 0.76, 0.552, 0.566, 0.664 and 0.607, respectively. With the implants, the correlation coefficients decreased sharply in VOI1. As the alpha angle increased from zero to 90°, the correlation coefficients increased and became significant. Similar results appeared in VOI2. In contrast, in VOI3, the correlation coefficient decreased as the alpha angle increased. CONCLUSIONS Metal artefacts were successfully quantified using microstructural parameters in terms of the image quality of the CBCT. Changes in alpha angle affected the quality of the CBCT image.
Collapse
Affiliation(s)
- Chang-Ki Min
- Research Institute of Clinical Medicine of Jeonbuk National University, Jeonju, South Korea.,Department of Oral and Maxillofacial Radiology, School of Dentistry, Backjedaero 567, School of Dentistry, Jeonbuk National University, Jeonju, South Korea
| | - Kyoung-A Kim
- Research Institute of Clinical Medicine of Jeonbuk National University, Jeonju, South Korea.,Department of Oral and Maxillofacial Radiology, School of Dentistry, Backjedaero 567, School of Dentistry, Jeonbuk National University, Jeonju, South Korea
| |
Collapse
|
17
|
Mancini AXM, Santos MUC, Gaêta-Araujo H, Tirapelli C, Pauwels R, Oliveira-Santos C. Artefacts at different distances from titanium and zirconia implants in cone-beam computed tomography: effect of tube current and metal artefact reduction. Clin Oral Investig 2021; 25:5087-5094. [PMID: 33544197 DOI: 10.1007/s00784-021-03821-y] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/22/2020] [Accepted: 01/29/2021] [Indexed: 11/28/2022]
Abstract
OBJECTIVES To evaluate the effect of cone-beam computed tomography (CBCT) tube current (mA) on the magnitude of artefacts at different distances from titanium or zirconia implants, with and without activation of a proprietary metal artefact reduction (MAR). MATERIAL AND METHODS Human mandibles were scanned on an OP300 Maxio CBCT unit (Instrumentarium, Tuusula, Finland) before and after the installation of dental implants, with four different tube currents (4 mA, 6.3 mA, 8 mA and 10 mA), with and without activation of proprietary MAR. The effect of mA on the standard deviation (SD) of gray values and contrast to noise ratio (CNR) were assessed in regions of interest located 1.5 cm, 2.5 cm, and 3.5 cm from implants. RESULTS In the presence of titanium implants, a significant decrease in SD was found by increasing tube current from 4 mA to 6.3 mA or 8 mA. For zirconia implants, 8 mA yielded better results for all distances. MAR improved CNR in the presence of zirconia implants at all distances, whereas no differences were observed with the use of MAR for titanium implants. CONCLUSION Increased tube current can improve overall image quality in the presence of implants, at all the distances tested. When a zirconia implant is present, such increase in mA should be higher in comparison to that for examinations with titanium implants. Activation of OP300 Maxio proprietary MAR improved image quality only among examinations with zirconia implants. CLINICAL RELEVANCE Artefact-generating implants are common in the field of view of CBCT examinations. Optimal exposure parameters, such as tube current, ensure high image quality with lowest possible radiation exposure.
Collapse
Affiliation(s)
- Arthur Xavier Maseti Mancini
- Department of Dental Materials and Prosthodontics, School of Dentistry of Ribeirao Preto, University of Sao Paulo, Av. Do Café, s/n, Ribeirao Preto, Sao Paulo, 14040-904, Brazil.
| | - Matheus Urias Cruz Santos
- Department of Stomatology, Public Oral Health and Forensic Dentistry, Division of Oral Radiology, School of Dentistry of Ribeirao Preto, University of Sao Paulo, Av. Do Café, s/n, Ribeirao Preto, Sao Paulo, 14040-904, Brazil
| | - Hugo Gaêta-Araujo
- Department of Oral Diagnosis, Division of Oral Radiology, Piracicaba Dental School, University of Campinas, Av. Limeira, 901, Piracicaba, São Paulo, 13414-903, Brazil
| | - Camila Tirapelli
- Department of Dental Materials and Prosthodontics, School of Dentistry of Ribeirao Preto, University of Sao Paulo, Av. Do Café, s/n, Ribeirao Preto, Sao Paulo, 14040-904, Brazil
| | - Ruben Pauwels
- Medical Physics & Quality Assessment, Department of Imaging & Pathology, Catholic University of Leuven, Leuven, Belgium and Aarhus Institute of Advanced Studies, Aarhus University, Høegh-Guldbergs Gade 6B, 8000, Aarhus, Denmark
| | - Christiano Oliveira-Santos
- Department of Stomatology, Public Oral Health and Forensic Dentistry, Division of Oral Radiology, School of Dentistry of Ribeirao Preto, University of Sao Paulo, Av. Do Café, s/n, Ribeirao Preto, Sao Paulo, 14040-904, Brazil
| |
Collapse
|
18
|
Phaneuf T, Kishen A, Moayedi M, Lam EWN. Effectiveness of Commercial Software-Enhanced Image Artifact Reduction Software. J Endod 2021; 47:820-826. [PMID: 33548328 DOI: 10.1016/j.joen.2020.11.028] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/21/2020] [Revised: 11/23/2020] [Accepted: 11/29/2020] [Indexed: 10/22/2022]
Abstract
INTRODUCTION Artifact reduction (AR) software has been incorporated into some cone-beam computed tomographic (CBCT) systems to reduce the severity of beam hardening (BH) artifacts and improve image quality. This study quantifies BH artifact and evaluates the effectiveness of AR in 2 CBCT systems. METHODS Palatal roots of Dent-Alike (Dentsply Sirona, Tulsa, OK) teeth were prepared and root filled with gutta-percha and EndoSequence BC Sealer (Brasseler, Savannah, GA). Six teeth were imaged with and without AR software using the ProMax3D (Planmeca Oy, Helsinki, Finland) and the Pax-i3D (Vatech, Hwaseong-si, South Korea) systems. FSL (FMRIB, Oxford, UK) software was used to quantify the light and dark components of the BH artifact along the tooth root using a specific region of interest approach and an image-wide analysis approach. Statistical analysis was performed using paired t tests and corrected for multiple comparisons with cluster mass correction using a nonparametric statistical analysis to evaluate the differences in the artifact volumes and areas with and without AR. RESULTS A significant reduction in the light artifact was observed with the Planmeca system (P < .05), but no significant differences were observed for either the light or dark artifacts with the Vatech system when AR was applied. There were also significant reductions in the volumes of light and dark artifacts along the entire root length when the AR was applied with the Planmeca system (cluster mass P < .05), but no significant differences were observed with the Vatech system. CONCLUSIONS Proprietary AR software is not equally effective in reducing the light and/or dark components of CBCT BH artifacts.
Collapse
Affiliation(s)
- Tyler Phaneuf
- Faculty of Dentistry, The University of Toronto, Toronto, Ontario, Canada
| | - Anil Kishen
- Faculty of Dentistry, The University of Toronto, Toronto, Ontario, Canada
| | - Massieh Moayedi
- Faculty of Dentistry, The University of Toronto, Toronto, Ontario, Canada
| | - Ernest W N Lam
- Faculty of Dentistry, The University of Toronto, Toronto, Ontario, Canada.
| |
Collapse
|
19
|
Shahmirzadi S, Sharaf RA, Saadat S, Moore WS, Geha H, Tamimi D, Demirturk Kocasarac H. Assessment of the efficiency of a pre- versus post-acquisition metal artifact reduction algorithm in the presence of 3 different dental implant materials using multiple CBCT settings: An in vitro study. Imaging Sci Dent 2021; 51:1-7. [PMID: 33828955 PMCID: PMC8007401 DOI: 10.5624/isd.20200094] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/25/2020] [Revised: 11/24/2020] [Accepted: 11/25/2020] [Indexed: 12/21/2022] Open
Abstract
Purpose The aim of this study was to assess artifacts generated in cone-beam computed tomography (CBCT) of 3 types of dental implants using 3 metal artifact reduction (MAR) algorithm conditions (pre-acquisition MAR, postacquisition MAR, and no MAR), and 2 peak kilovoltage (kVp) settings. Materials and Methods Titanium-zirconium, titanium, and zirconium alloy implants were placed in a dry mandible. CBCT images were acquired using 84 and 90 kVp and at normal resolution for all 3 MAR conditions. The images were analyzed using ImageJ software (National Institutes of Health, Bethesda, MD) to calculate the intensity of artifacts for each combination of material and settings. A 3-factor analysis of variance model with up to 3-way interactions was used to determine whether there was a statistically significant difference in the mean intensity of artifacts associated with each factor. Results The analysis of all 3 MAR conditions showed that using no MAR resulted in substantially more severe artifacts than either of the 2 MAR algorithms for the 3 implant materials; however, there were no significant differences between pre- and post-acquisition MAR. The 90 kVp setting generated less intense artifacts on average than the 84 kVp setting. The titanium-zirconium alloy generated significantly less intense artifacts than zirconium. Titanium generated artifacts at an intermediate level relative to the other 2 implant materials, but was not statistically significantly different from either. Conclusion This in vitro study suggests that artifacts can be minimized by using a titanium-zirconium alloy at the 90 kVp setting, with either MAR setting.
Collapse
Affiliation(s)
- Solaleh Shahmirzadi
- Department of Diagnostic Sciences, Division of Oral and Maxillofacial Radiology, Texas A&M College of Dentistry, Dallas, TX, USA
| | - Rana A Sharaf
- Department of Comprehensive Dentistry, Division of Oral and Maxillofacial Radiology, University of Texas Health Science Center, San Antonio, TX, USA
| | - Sarang Saadat
- Department of Oral and Maxillofacial Surgery, University of Texas Health Science Center, San Antonio, TX, USA
| | - William S Moore
- Department of Comprehensive Dentistry, Division of Oral and Maxillofacial Radiology, University of Texas Health Science Center, San Antonio, TX, USA
| | - Hassem Geha
- Department of Comprehensive Dentistry, Division of Oral and Maxillofacial Radiology, University of Texas Health Science Center, San Antonio, TX, USA
| | - Dania Tamimi
- Private Practice, Oral and Maxillofacial Radiology, Orlando, FL, USA
| | - Husniye Demirturk Kocasarac
- Department of General Dental Sciences, Division of Oral and Maxillofacial Radiology, Marquette University School of Dentistry, Milwaukee, WI, USA
| |
Collapse
|
20
|
Hedayatipanah M, Salemi F, Kamyari N, Yalpanian A. Measurement of Peri-Implant Bone Width with and without Metal Artifact Reduction Algorithm Using Two Cone-Beam Computed Tomography Software Programs. PESQUISA BRASILEIRA EM ODONTOPEDIATRIA E CLÍNICA INTEGRADA 2021. [DOI: 10.1590/pboci.2021.118] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/22/2022] Open
|
21
|
Muellensiefen M, Tins B, Kuiper JH, Weber MA, Krakowski-Roosen H. Development of a total hip replacement phantom for the assessment of CT-image quality. Acta Radiol 2020; 61:1644-1652. [PMID: 32151141 DOI: 10.1177/0284185120907981] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/16/2022]
Abstract
BACKGROUND The quality of computed tomography (CT) imaging is important when used to judge the success of joint replacement surgery. Metal artefacts are a known source of error, typically compensated by noise reduction software. PURPOSE To develop a transportable and stable system for the assessment of image quality of bone lesions around orthopedic implants. MATERIAL AND METHODS The design and manufacture of a bone-implant-phantom is described, which is based on a calf acetabulum with surrounding pelvic bone structures. Bone lesions of several sizes were created in the acetabulum before implanting the cup of an uncemented hip prosthesis, which was fixed with a stainless-steel bone screw. Plastic strips were placed on a cobalt-chromium stemmed femoral component, simulating typical bone lesions around loosening or infected prostheses, before embedding the stem in material similar to bone and shaped like a femur. The head of the femoral component was then placed in the acetabular cup and CT scans were produced. RESULTS It was possible to construct a durable CT hip phantom for quality assurance work. The usability of different materials and the choices made for the phantom are discussed. CONCLUSION It is possible to construct a durable joint implant phantom for quality assurance and scanner hardware and software assessment with limited resources. The phantom was successfully used in the assessment of the hardware and software performance of different CT scanners.
Collapse
Affiliation(s)
- Mara Muellensiefen
- Applied Sport Sciences, University of Applied Sciences Hamm-Lippstadt, Hamm, Germany
- Department of Radiology, Robert Jones and Agnes Hunt Orthopaedic Hospital, Oswestry, UK
| | - Bernhard Tins
- Department of Radiology, Robert Jones and Agnes Hunt Orthopaedic Hospital, Oswestry, UK
| | - Jan-Herman Kuiper
- Institute for Science and Technology in Medicine, Keele University/Robert Jones and Agnes Hunt Orthopaedic Hospital, Oswestry, UK
| | - Marc-André Weber
- Institute of Diagnostic and Interventional Radiology, University Medical Center Rostock, Rostock, Germany
| | | |
Collapse
|
22
|
Gaêta‐Araujo H, Nascimento EHL, Oliveira‐Santos N, Pinheiro MCR, Coelho‐Silva F, Oliveira‐Santos C. Influence of adjacent teeth restored with metal posts in the detection of simulated internal root resorption using CBCT. Int Endod J 2020; 53:1299-1306. [DOI: 10.1111/iej.13348] [Citation(s) in RCA: 7] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/03/2020] [Accepted: 06/09/2020] [Indexed: 02/01/2023]
Affiliation(s)
- H. Gaêta‐Araujo
- Division of Oral Radiology Department of Oral Diagnosis Piracicaba Dental School University of Campinas (UNICAMP) PiracicabaBrazil
| | - E. H. L. Nascimento
- Division of Oral Radiology Department of Oral Diagnosis Piracicaba Dental School University of Campinas (UNICAMP) PiracicabaBrazil
| | - N. Oliveira‐Santos
- Division of Oral Radiology Department of Oral Diagnosis Piracicaba Dental School University of Campinas (UNICAMP) PiracicabaBrazil
| | - M. C. R. Pinheiro
- Division of Oral Radiology Department of Oral Diagnosis Piracicaba Dental School University of Campinas (UNICAMP) PiracicabaBrazil
| | - F. Coelho‐Silva
- Division of Oral Radiology Department of Oral Diagnosis Piracicaba Dental School University of Campinas (UNICAMP) PiracicabaBrazil
| | - C. Oliveira‐Santos
- Division of Oral Radiology Department of Stomatology, Public Oral Health, Forensic Dentistry School of Dentistry of Ribeirao Preto University of Sao Paulo (USP) Ribeirao Preto Brazil
| |
Collapse
|
23
|
Reducing metal artifacts between implants in cone-beam CT by adjusting angular position of the subject. Oral Radiol 2020; 37:385-394. [PMID: 32638201 DOI: 10.1007/s11282-020-00458-7] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/29/2020] [Accepted: 06/19/2020] [Indexed: 12/14/2022]
Abstract
OBJECTIVES To reduce inter-implant metal artifacts in cone-beam CT (CBCT) imaging by adjusting angular position of the subject relative to the source-detector plane. MATERIALS AND METHODS Two dental implants were placed in a block made of homogeneous dental impression material. Using a custom-made apparatus, the specimen was scanned with a CBCT machine at seven different angles (0°, 15°, 30°, 45°, 60°, 75°, and 90°) along three different spatial axes, yielding 21 experimental groups. Thirteen volumes of interest (VOI) including inter- and peri-implant areas were selected from each axial reconstruction perpendicular to the implants. Gray values (GVs) of each pixel within these VOIs were measured. Mean differences in GV (ΔGV) between the VOIs and control area were calculated and expressed as a percentage. These ΔGVs from different spatial angle were compared and analyzed by Welch's analysis of variance (ANOVA) and linear regression using SPSS 25.0 software. RESULTS As alpha angle increased, the ΔGV of the inter-implant area increased from - 62.02% to near-zero while the standard deviation decreased. Welch's ANOVA and linear regression analysis revealed ΔGV increased significantly with alpha angle (p < 0.001, R2 = 0.406). VOIs on the extension line of two implants showed similar results. After adjusting the beta and gamma angles, there was no significant change in ΔGV. CONCLUSIONS Increasing the alpha angle can reduce metal artifacts in the inter-implant area in CBCT images.
Collapse
|
24
|
Gaêta-Araujo H, Nascimento EHL, Fontenele RC, Mancini AXM, Freitas DQ, Oliveira-Santos C. Magnitude of beam-hardening artifacts produced by gutta-percha and metal posts on cone-beam computed tomography with varying tube current. Imaging Sci Dent 2020; 50:1-7. [PMID: 32206614 PMCID: PMC7078413 DOI: 10.5624/isd.2020.50.1.1] [Citation(s) in RCA: 25] [Impact Index Per Article: 6.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/30/2019] [Revised: 09/26/2019] [Accepted: 10/10/2019] [Indexed: 02/01/2023] Open
Abstract
Purpose This study was performed to evaluate the magnitude of artifacts produced by gutta-percha and metal posts on cone-beam computed tomography (CBCT) scans obtained with different tube currents and with or without metal artifact reduction (MAR). Materials and Methods A tooth was inserted in a dry human mandible socket, and CBCT scans were acquired after root canal instrumentation, root canal filling, and metal post placement with various tube currents with and without MAR activation. The artifact magnitude was assessed by the standard deviation (SD) of gray values and the contrast-to-noise ratio (CNR) at the various distances from the tooth. Data were compared using multi-way analysis of variance. Results At all distances, a current of 4 mA was associated with a higher SD and a lower CNR than 8 mA or 10 mA (P<0.05). For the metal posts without MAR, the artifact magnitude as assessed by SD was greatest at 1.5 cm or less (P<0.05). When MAR was applied, SD values for distances 1.5 cm or closer to the tooth were reduced (P<0.05). MAR usage did not influence the magnitude of artifacts in the control and gutta-percha groups (P>0.05). Conclusion Increasing the tube current from 4 mA to 8 mA may reduce the magnitude of artifacts from metal posts. The magnitude of artifacts arising from metal posts was significantly higher at distances of 1.5 cm or less than at greater distances. MAR usage improved image quality near the metal post, but had no significant influence farther than 1.5 cm from the tooth.
Collapse
Affiliation(s)
- Hugo Gaêta-Araujo
- Department of Oral Diagnosis, Division of Oral Radiology, Piracicaba Dental School, University of Campinas, Piracicaba, Sao Paulo, Brazil
| | - Eduarda Helena Leandro Nascimento
- Department of Oral Diagnosis, Division of Oral Radiology, Piracicaba Dental School, University of Campinas, Piracicaba, Sao Paulo, Brazil
| | - Rocharles Cavalcante Fontenele
- Department of Oral Diagnosis, Division of Oral Radiology, Piracicaba Dental School, University of Campinas, Piracicaba, Sao Paulo, Brazil
| | - Arthur Xavier Maseti Mancini
- Department of Dental Materials and Prosthodontics, School of Dentistry of Ribeirao Preto, University of Sao Paulo, Ribeirao Preto, Sao Paulo, Brazil
| | - Deborah Queiroz Freitas
- Department of Oral Diagnosis, Division of Oral Radiology, Piracicaba Dental School, University of Campinas, Piracicaba, Sao Paulo, Brazil
| | - Christiano Oliveira-Santos
- Department of Stomatology, Public Oral Health and Forensic Dentistry, Division of Oral Radiology, School of Dentistry of Ribeirao Preto, University of Sao Paulo, Ribeirao Preto, Sao Paulo, Brazil
| |
Collapse
|
25
|
Bayrak S, Kursun Cakmak ES, Kamalak H. Contrast-to-noise ratios of different dental restorative materials: an in-vitro cone beam computed tomography study. Eur Oral Res 2020; 54:36-41. [PMID: 32518909 PMCID: PMC7252535 DOI: 10.26650/eor.20200079] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/20/2022] Open
Abstract
Purpose In radiological views, strong beam hardening and streaking artifacts occur due to high-density structures and polyenergetic X-ray beams, and these lead to misdiagnosis. This study was performed in vitro to compare the contrast-to-noise ratio (CNR) of commonly used dental restorative materials by using Cone Beam Computed Tomography (CBCT) images with and without artifact reduction (AR) mode. Materials and methods A total of 108 molar teeth were restored with nine different groups of restorative materials, with each group containing 12 teeth. Teeth were placed in a dry human mandible and scanned, one by one, via Planmeca 3D ProMax (Planmeca, Helsinki, Finland) with and without AR mode. Images were analyzed using ImageJ software (National Institutes of Health, Bethesda, MD) to calculate the CNR. Results CNR was calculated to be the highest in compomer (Glassiosite) images without AR mode (mean: 3.36) and with AR mode (mean: 3.61). CNR was calculated to be the lowest in amalgam (Tytin) images without AR mode (mean: 0.21) and with AR mode (mean: 0.23). A significant difference was found between materials in terms of CNR measurements (p ≤ 0.05). CNR measurements were increased after the AR mode application (p ≤ 0.05). Conclusion AR mode was effective in reducing artifacts arising from dental materials on CBCT images, so it is necessary to use AR mode for correct diagnoses.
Collapse
Affiliation(s)
- Seval Bayrak
- Abant İzzet Baysal University, Dentistry Faculty,Dentomaxillofacial Radiology Department, Bolu,Turkey
| | | | - Hakan Kamalak
- Kahramanmaras Sütcü İmam University, Dentistry Faculty, Department of Restorative Dentistry, Kahramanmaras,Turkey
| |
Collapse
|
26
|
Knaus J, Schaffarczyk D, Cölfen H. On the Future Design of Bio-Inspired Polyetheretherketone Dental Implants. Macromol Biosci 2019; 20:e1900239. [PMID: 31802617 DOI: 10.1002/mabi.201900239] [Citation(s) in RCA: 32] [Impact Index Per Article: 6.4] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/07/2019] [Revised: 10/10/2019] [Indexed: 11/09/2022]
Abstract
Polyetheretherketone (PEEK) is a promising implant material because of its excellent mechanical characteristics. Although this polymer is a standard material in spinal applications, PEEK is not in use in the manufacturing of dental implants, where titanium is still the most-used material. This may be caused by its relative bio-inertness. By the use of various surface modification techniques, efforts have been made to enhance its osseointegrative characteristics to enable the polymer to be used in dentistry. In this feature paper, the state-of-the-art for dental implants is given and different surface modification techniques of PEEK are discussed. The focus will lie on a covalently attached surface layer mimicking natural bone. The usage of such covalently anchored biomimetic composite materials combines many advantageous properties: A biocompatible organic matrix and a mineral component provide the cells with a surrounding close to natural bone. Bone-related cells may not recognize the implant as a foreign body and therefore, may heal and integrate faster and more firmly. Because neither metal-based nor ceramics are ideal material candidates for a dental implant, the combination of PEEK and a covalently anchored mineralized biopolymer layer may be the start of the desired evolution in dental surgery.
Collapse
Affiliation(s)
- Jennifer Knaus
- Department of Chemistry, Physical Chemistry, University of Konstanz, Universitätsstraße 10, 78457, Konstanz, Germany.,stimOS GmbH, Byk-Gulden-Straße 2, 78467, Konstanz, Germany
| | | | - Helmut Cölfen
- Department of Chemistry, Physical Chemistry, University of Konstanz, Universitätsstraße 10, 78457, Konstanz, Germany
| |
Collapse
|
27
|
Derksen W, Wismeijer D, Flügge T, Hassan B, Tahmaseb A. The accuracy of computer-guided implant surgery with tooth-supported, digitally designed drill guides based on CBCT and intraoral scanning. A prospective cohort study. Clin Oral Implants Res 2019; 30:1005-1015. [PMID: 31330566 DOI: 10.1111/clr.13514] [Citation(s) in RCA: 73] [Impact Index Per Article: 14.6] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/19/2018] [Revised: 03/31/2019] [Accepted: 03/31/2019] [Indexed: 11/29/2022]
Abstract
OBJECTIVES The purpose of this prospective cohort study was to evaluate computer-guided implant surgery with tooth-supported drill guides based on CBCT scans and intraoral scanning. MATERIALS AND METHODS For partially edentulous patients, a prosthetic and surgical planning was completed in the guided surgery software (coDiagnostiX) and drill guides were 3D-printed accordingly. Three months after implant placement, an intraoral scan of the implant's position was used to evaluate the accuracy of placement using the coDiagnostiX treatment evaluation tool. Deviations were reported in degrees and in distance at implant's entry point and apex. Several risk factors, which might influence the accuracy, were evaluated separately: treated jaw, flap design, prior augmentations, amount of unrestored teeth, crowding, location of implants, cortical interference, and implant's length and diameter. RESULTS A total of 66 patients received 145 Straumann tissue level implants that were eligible for accuracy analysis. The mean angular deviation was 2.72° ± 1.42. The mean three-dimensional deviation at the implant's entry point was 0.75 mm ± 0.34. At implant's apex, the mean was 1.06 mm ± 0.44. The amount of unrestored teeth (p = .002 & p = .003), the implant's location (p < .001), the implant's length (p = .004), and cortical interference (p = .033) had a significant influence on the accuracy of placement. Implant survival was 99.3% (n = 1 failed implant) at 12 and 24 months. CONCLUSIONS Guided surgery with tooth-supported drill guides made in a digital workflow is a feasible treatment option. However, deviations do occur and the implant's length, location, cortical interference and the amount of unrestored teeth have a significant influence on the accuracy.
Collapse
Affiliation(s)
- Wiebe Derksen
- Section of Oral Implantology and Prosthetic Dentistry, Academic Centre for Dentistry Amsterdam (ACTA), Amsterdam, The Netherlands
| | - Daniel Wismeijer
- Section of Oral Implantology and Prosthetic Dentistry, Academic Centre for Dentistry Amsterdam (ACTA), Amsterdam, The Netherlands
| | - Tabea Flügge
- Department of Oral and Maxillofacial Surgery, Faculty of Medicine and Medical Center, University of Freiburg, Freiburg, Germany
| | - Bassam Hassan
- Section of Oral Implantology and Prosthetic Dentistry, Academic Centre for Dentistry Amsterdam (ACTA), Amsterdam, The Netherlands
| | - Ali Tahmaseb
- Section of Oral Implantology and Prosthetic Dentistry, Academic Centre for Dentistry Amsterdam (ACTA), Amsterdam, The Netherlands
| |
Collapse
|
28
|
Shokri A, Jamalpour MR, Khavid A, Mohseni Z, Sadeghi M. Effect of exposure parameters of cone beam computed tomography on metal artifact reduction around the dental implants in various bone densities. BMC Med Imaging 2019; 19:34. [PMID: 31035955 PMCID: PMC6489302 DOI: 10.1186/s12880-019-0334-4] [Citation(s) in RCA: 11] [Impact Index Per Article: 2.2] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/08/2018] [Accepted: 04/15/2019] [Indexed: 11/25/2022] Open
Abstract
Background This study aimed to assess the effect of exposure parameters such as milliampere (mA) and field of view (FOV) of cone beam computed tomography (CBCT) on a metal artifact of dental implants placed in different bone densities. Methods A total of 27 bone blocks with different densities (nine were type 1, nine were types 2 and 3, and nine were type 4) were used in this in vitro, experimental study. These blocks were placed in mandibular wax models. The blocks were scanned after drilling (hole preparation) and after implant placement using Cranex3D imaging system with a 4 × 6 cm2and 6 × 8 cm2 FOV and 4 and 10 mA. Gray value of the bone blocks was recorded before and after placement of implants. Results In general, irrespective of bone density, the amount of artifacts was lower in small FOV compared to large FOV (P < 0.05). Change of mA had no effect on metal artifacts (P > 0.05). Artifacts in type 4 bone were greater than in other bone types (P < 0.05). Difference between type 1 and types 2 and 3 was not significant (P > 0.05). Conclusion According to the results of this study, Peri-implant artifacts were seen in all bone types; the amount of artifacts in type 4 bone was higher than that in other types. Size of FOV and bone density affect the metal artifacts around dental implants; so that a smaller FOV can be used to decrease metal artifacts.
Collapse
Affiliation(s)
- Abbas Shokri
- Dental Implant Research Center, Department of Oral and Maxillofacial Radiology, Dental School, Hamadan University of Medical Sciences, Hamadan, Iran
| | - Mohammad Reza Jamalpour
- Dental Implant Research Center, Department of Oral and Maxillofacial Surgery, Dental School, Hamadan University of Medical Sciences, Hamadan, Iran
| | - Atefeh Khavid
- Oral and Maxillofacial Radiology Department, Faculty of Dentistry, Kermanshah University of Medical Sciences, Kermanshah, Iran.
| | - Zeinab Mohseni
- Dental Implant Research Center, Department of Oral and Maxillofacial Radiology, Dental School, Hamadan University of Medical Sciences, Hamadan, Iran
| | - Masoud Sadeghi
- Medical Biology Research Center, Kermanshah University of Medical Sciences, Kermanshah, Iran
| |
Collapse
|
29
|
Demirturk Kocasarac H, Ustaoglu G, Bayrak S, Katkar R, Geha H, Deahl ST, Mealey BL, Danaci M, Noujeim M. Evaluation of artifacts generated by titanium, zirconium, and titanium-zirconium alloy dental implants on MRI, CT, and CBCT images: A phantom study. Oral Surg Oral Med Oral Pathol Oral Radiol 2019; 127:535-544. [PMID: 30879914 DOI: 10.1016/j.oooo.2019.01.074] [Citation(s) in RCA: 39] [Impact Index Per Article: 7.8] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/29/2018] [Revised: 01/16/2019] [Accepted: 01/20/2019] [Indexed: 02/07/2023]
Abstract
OBJECTIVE The aim of this study was to assess artifacts generated by zirconium, titanium, and titanium-zirconium alloy implants on magnetic resonance imaging(MRI), computed tomography(CT), and cone beam computed tomography(CBCT) and to correlate the findings to the dose-area product and exposure factors on CT and CBCT. STUDY DESIGN Three phantoms were built by embedding zirconium, titanium, and titanium-zirconium implants in ultrasound gel. MRI, CT, and CBCT images were acquired by using multiple sequences and settings. For MRI, "artifact" was described as the length of signal void beyond the limits of the implant. For CT and CBCT, "artifact" was calculated by subtracting the gray level of the darkest pixel from the level of the lightest pixel. RESULTS On MRI, zirconium implants had minor distortion artifacts, whereas titanium and titanium-zirconium implants created extensive artifacts (P < .05). On CT and CBCT, artifacts were less prominent with titanium and titanium-zirconium implants compared with zirconium (P < .05). Titanium grade 5 implants with 0.3 and 0.4 mm3 voxels produced the least severe artifacts. CONCLUSIONS MRI images were less affected by artifacts from zirconium implants, whereas CT and CBCT images showed less severe artifacts from titanium and titanium-zirconium alloy implants. CT generated greater artifacts compared with CBCT. Larger CBCT voxel sizes reduced the dose-area product and the severity of artifacts.
Collapse
Affiliation(s)
- Husniye Demirturk Kocasarac
- Department of Comprehensive Dentistry, University of Texas Health San Antonio, TX, USA and Department of General Dental Sciences, Marquette University, Milwaukee, WI, USA.
| | - Gulbahar Ustaoglu
- Chair, Department of Periodontology, Abant Izzet Baysal University, Bolu, Turkey
| | - Seval Bayrak
- Chair, Department of Oral and Maxillofacial Radiology, Abant Izzet Baysal University, Bolu, Turkey
| | - Rujuta Katkar
- Department of Comprehensive Dentistry, University of Texas Health San Antonio, TX, USA and Department of General Dental Sciences, Marquette University, Milwaukee, WI, USA
| | - Hassem Geha
- Department of Comprehensive Dentistry, University of Texas Health San Antonio, TX, USA and Department of General Dental Sciences, Marquette University, Milwaukee, WI, USA
| | - S Thomas Deahl
- Department of Comprehensive Dentistry, University of Texas Health San Antonio, TX, USA and Department of General Dental Sciences, Marquette University, Milwaukee, WI, USA
| | - Brian L Mealey
- Graduate Program Director, Department of Periodontology, University of Texas Health San Antonio, TX, USA
| | - Murat Danaci
- Chair, Department of Radiology, School of Medicine, Ondokuz Mayıs University, Samsun, Turkey
| | - Marcel Noujeim
- Department of Comprehensive Dentistry, University of Texas Health San Antonio, TX, USA and Department of General Dental Sciences, Marquette University, Milwaukee, WI, USA
| |
Collapse
|
30
|
Abstract
In the last several decades, the need for 3D images in dentistry have developed. Computerized tomography was first introduced mainly with the advent of implantology, but its use remained limited to a small number of specialists, due to its indications, access and dose radiation. In the late 90's, a new technology using a cone-shaped beam and a reciprocating detector, which rotates around the patient 360 degrees and acquires projected data in a single rotation, namely the cone beam computerized tomography (CBCT), invaded dentistry, making the perception of 3D easily acceptable to dentists and their patients.
Collapse
Affiliation(s)
- Ibrahim Nasseh
- Department of Oral and Maxillofacial Radiology, Lebanese University, School of Dentistry, PO Box 166598, Beirut, Lebanon.
| | - Wisam Al-Rawi
- Private Practice, Horizon Dental, 742 Broadway, El Cajon, CA 92021, USA
| |
Collapse
|
31
|
Nikbin A, Dalili Kajan Z, Taramsari M, Khosravifard N. Effect of object position in the field of view and application of a metal artifact reduction algorithm on the detection of vertical root fractures on cone-beam computed tomography scans: An in vitro study. Imaging Sci Dent 2018; 48:245-254. [PMID: 30607348 PMCID: PMC6305778 DOI: 10.5624/isd.2018.48.4.245] [Citation(s) in RCA: 16] [Impact Index Per Article: 2.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/15/2018] [Revised: 08/14/2018] [Accepted: 08/24/2018] [Indexed: 01/28/2023] Open
Abstract
Purpose To assess the effects of object position in the field of view (FOV) and application of a metal artifact reduction (MAR) algorithm on the diagnostic accuracy of cone-beam computed tomography (CBCT) for the detection of vertical root fractures (VRFs). Materials and Methods Sixty human single-canal premolars received root canal treatment. VRFs were induced in 30 endodontically treated teeth. The teeth were then divided into 4 groups, with 2 groups receiving metal posts and the remaining 2 only having an empty post space. The roots from different groups were mounted in a phantom made of cow rib bone, and CBCT scans were obtained for the 4 different groups. Three observers evaluated the images independently. Results The highest frequency of correct diagnoses of VRFs was obtained with the object positioned centrally in the FOV, using the MAR algorithm. Peripheral positioning of the object without the MAR algorithm yielded the highest sensitivity for the first observer (66.7%). For the second and third observers, a central position improved sensitivity, with or without the MAR algorithm. In the presence of metal posts, central positioning of the object in the FOV significantly increased the diagnostic sensitivity and accuracy compared to peripheral positioning. Conclusion Diagnostic accuracy was higher with central positioning than with peripheral positioning, irrespective of whether the MAR algorithm was applied. However, the effect of the MAR algorithm was more significant with central positioning than with peripheral positioning of the object in the FOV. The clinical experience and expertise of the observers may serve as a confounder in this respect.
Collapse
Affiliation(s)
- Ava Nikbin
- Department of Maxillofacial Radiology, Faculty of Dentistry, Guilan University of Medical Sciences, Rasht, Iran
| | - Zahra Dalili Kajan
- Dental Sciences Research Center, Department of Maxillofacial Radiology, Faculty of Dentistry, Guilan University of Medical Sciences, Rasht, Iran
| | - Mehran Taramsari
- Dental Sciences Research Center, Department of Endodontics, Faculty of Dentistry, Guilan University of Medical Sciences, Rasht, Iran
| | - Negar Khosravifard
- Dental Sciences Research Center, Department of Maxillofacial Radiology, Faculty of Dentistry, Guilan University of Medical Sciences, Rasht, Iran
| |
Collapse
|
32
|
Freitas DQ, Fontenele RC, Nascimento EHL, Vasconcelos TV, Noujeim M. Influence of acquisition parameters on the magnitude of cone beam computed tomography artifacts. Dentomaxillofac Radiol 2018; 47:20180151. [PMID: 29916722 DOI: 10.1259/dmfr.20180151] [Citation(s) in RCA: 43] [Impact Index Per Article: 7.2] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/16/2023] Open
Abstract
AIM To evaluate the influence of kilovoltage (kVp) and metal artifact reduction tool (MAR) on the magnitude of cone beam CT (CBCT) artifacts. METHODS A titanium and zirconia implants were inserted alternately in a posterior region of a mandible. CBCT exams were acquired with ProMax 3D (Planmeca Oy, Helsinki, Finland) and Picasso Trio machines (Vatech, Hwaseong, South Korea) using 70 kVp, 80 kVp and 90 kVp with and without MAR activation. The other exposure factors remained fixed at 5mA, field of view 80 × 50 mm and voxel 0.20 mm. The scans were performed before and after the insertion of the implants. Regions of interest were determined in different distances from the artifact production area (15, 25 and 35 mm) in an axial image, in which standard deviation (SD) of grayscale values was measured and contrast-to-noise ratio (CNR) was calculated. Analysis of variance was used to compare the data. RESULTS Overall, in cases where the artifact was pronounced, MAR was efficient in reducing SD values. MAR also improved the CNR of ProMax images, but did not affect the Picasso images. Additionally, the higher was the kVp, the lower was the SD value and the higher was the CNR in both machines. CONCLUSION In both machines, increasing kVp and MAR are effective in decreasing the CBCT artifacts in all their magnitude when they are pronounced. Therefore, the professionals should choose one of those options or even both considering the purpose of the CBCT imaging and radiation dose for the patient.
Collapse
Affiliation(s)
- Deborah Queiroz Freitas
- 1 Department of Oral Diagnosis, Division of Oral Radiology, Piracicaba Dental School, University of Campinas , Limeira , Brazil
| | - Rocharles Cavalcante Fontenele
- 1 Department of Oral Diagnosis, Division of Oral Radiology, Piracicaba Dental School, University of Campinas , Limeira , Brazil
| | | | | | - Marcel Noujeim
- 3 Department of Comprehensive Dentistry, Division of Oral and Maxillofacial Radiology, University of Texas Health Science Center at San Antonio , San Antonio, TX , United States
| |
Collapse
|
33
|
Machado AH, Fardim KAC, de Souza CF, Sotto-Maior BS, Assis NMSP, Devito KL. Effect of anatomical region on the formation of metal artefacts produced by dental implants in cone beam computed tomographic images. Dentomaxillofac Radiol 2018; 47:20170281. [PMID: 29231055 DOI: 10.1259/dmfr.20170281] [Citation(s) in RCA: 21] [Impact Index Per Article: 3.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/07/2023] Open
Abstract
OBJECTIVES To quantitatively compare metal artefacts produced by implants in different maxillomandibular regions on cone beam CT (CBCT) images. METHODS A total of 200 implants selected from CBCT examinations were divided into four groups: Group 1 (n = 50)-implants located in the anterior maxilla; Group 2 (n = 50)-implants located in the posterior maxilla; Group 3 (n = 50)-implants located in the anterior mandible and Group 4 (n = 50)-implants located in the posterior mandible. The implants were further classified as isolated or adjacent to other implants. Three axial reconstructions were selected for each sampled implant (apical, middle and cervical). On each slice, the artefacts produced by the implants were counted. The Mann-Whitney test was used to compare the variables between groups. The Kruskal-Wallis and Student-Newman-Keuls tests were used to compare the axial reconstructions. RESULTS The mandible showed a greater number of artefacts than the maxilla (apical image: p = 0.0024; middle image: p < 0.0001). The anterior region produced more artefacts than the posterior region (apical image: p = 0.0105; middle image: p < 0.0316). There was no significant difference in the number of artefacts between isolated and adjacent implants, and the cervical image was most affected by artefacts. CONCLUSIONS Dental implants always produce metal artefacts in CBCT images, and these artefacts are affected by the anatomical location in the dental arch.
Collapse
Affiliation(s)
- Alessiana Helena Machado
- 1 Master's Program in Dental Clinic, School of Dentistry, Federal University of Juiz de Fora , Juiz de Fora, Minas Gerais , Brazil
| | | | - Camila Furtado de Souza
- 1 Master's Program in Dental Clinic, School of Dentistry, Federal University of Juiz de Fora , Juiz de Fora, Minas Gerais , Brazil
| | - Bruno Salles Sotto-Maior
- 2 Department of Restorative Dentistry, School of Dentistry, Federal University of Juiz de Fora , Juiz de Fora, Minas Gerais , Brazil
| | | | - Karina Lopes Devito
- 3 Department of Dental Clinic, School of Dentistry, Federal University of Juiz de Fora , Juiz de Fora, Minas Gerais , Brazil
| |
Collapse
|
34
|
Fakhar HB, Rashtchian R, Parvin M. Effect of Dental Implant Metal Artifacts on Accuracy of Linear Measurements by Two Cone-Beam Computed Tomography Systems Before and After Crown Restoration. JOURNAL OF DENTISTRY (TEHRAN, IRAN) 2017; 14:329-336. [PMID: 29942327 PMCID: PMC6015588] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Indexed: 11/23/2022]
Abstract
OBJECTIVES The aim of this study was to determine the impact of fixture location and crown restoration on the accuracy of linear measurements by two cone-beam computed tomography (CBCT) systems. MATERIALS AND METHODS Six dental implants were inserted in a dry human mandible in two stages. CBCT images were obtained in each stage by Alphard VEGA 3030 and Promax 3D Max systems. Imaging procedures were repeated after metallic crown placement. Two observers measured the alveolar height and width using five radiopaque markers. Values were compared to the same measurements made on initial images (prior to implant insertion) using t-test. The linear regression test was used to evaluate the effect of implant location on the accuracy of linear measurements. RESULTS The impact of fixture and fixture-crown combination on the accuracy of linear measurements of height (t = -5.2, P=0.0001 and t=-5.98, P<0.0001, respectively) and width (t=-3.42, P=0.004 and t= -2.7, P=0.015, respectively) was significantly underestimated. Metal crowns had no significant effect on measurements of bone height and width (t=-1.38, P=0.19 and t=0, P=1.00, respectively). Although both systems showed some underestimations, Promax 3D Max underestimated bone width significantly more than the other system (Alphard VEGA 3030=- 0.51mm and Promax 3D Max=-0.80). Regarding implant location, the measurements in the canine sites were found to be more accurate than the region between adjacent implants. CONCLUSIONS CBCT is an accurate and reproducible system for dental implant follow-up examinations. Metal artifacts can lead to underestimation of measurements. However, this was not statistically significant in our study.
Collapse
Affiliation(s)
- Hoorieh Bashizadeh Fakhar
- Assistant Professor, Dental Research Center, Dentistry Research Institute, Tehran University of Medical Sciences, Tehran, Iran; Department of Oral and Maxillofacial Radiology, School of Dentistry, Tehran University of Medical Sciences, Tehran, Iran
| | - Roxana Rashtchian
- Postgraduate Student, Department of Oral and Maxillofacial Radiology, School of Dentistry, Tehran University of Medical Sciences, Tehran, Iran,Corresponding author: R. Rashtchian, Department of Oral and Maxillofacial Radiology, School of Dentistry, Tehran University of Medical Sciences, Tehran, Iran,
| | - Milad Parvin
- Postgraduate Student, Department of Oral and Maxillofacial Surgery, School of Dentistry, Tehran University of Medical Sciences, Tehran, Iran
| |
Collapse
|
35
|
The effects of different restorative materials on the detection of approximal caries in cone-beam computed tomography scans with and without metal artifact reduction mode. Oral Surg Oral Med Oral Pathol Oral Radiol 2017; 123:392-400. [DOI: 10.1016/j.oooo.2016.11.008] [Citation(s) in RCA: 20] [Impact Index Per Article: 2.9] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/21/2016] [Revised: 10/26/2016] [Accepted: 11/22/2016] [Indexed: 11/20/2022]
|
36
|
Queiroz PM, Santaella GM, da Paz TDJ, Freitas DQ. Evaluation of a metal artefact reduction tool on different positions of a metal object in the FOV. Dentomaxillofac Radiol 2017; 46:20160366. [PMID: 27910700 DOI: 10.1259/dmfr.20160366] [Citation(s) in RCA: 38] [Impact Index Per Article: 5.4] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/05/2022] Open
Abstract
OBJECTIVES To evaluate the action of a metal artefact reduction (MAR) tool when artefact-generator metal object is at different positions in the field of view (FOV). METHODS A cylindrical utility wax phantom, with a metal alloy sample inside, was made. The phantom was positioned centrally and peripherally in the FOV for image acquisition, with and without the MAR tool activation. The standard deviation values (image noise levels) from areas around the metal sample and the control area were obtained. The numbers were compared by Student's t-test (α = 0.05). RESULTS When the tool was activated, a significant difference of image noise was observed for central and peripheral positioning, for both control area (p = 0.0012) and metal area (p = 0.03), and a smaller level of noise was observed for images with phantoms in central positioning. A decrease in image noise with the tool activated was found only in phantoms with the metal object positioned centrally in the FOV. CONCLUSIONS For the MAR tool to be effective, the artefact-generator object needs to be in the central region of the FOV.
Collapse
Affiliation(s)
- Polyane M Queiroz
- Department of Oral Diagnosis, Area of Oral Radiology, Piracicaba Dental School, University of Campinas, Piracicaba, Sao Paulo, Brazil
| | - Gustavo M Santaella
- Department of Oral Diagnosis, Area of Oral Radiology, Piracicaba Dental School, University of Campinas, Piracicaba, Sao Paulo, Brazil
| | - Thais D J da Paz
- Department of Oral Diagnosis, Area of Oral Radiology, Piracicaba Dental School, University of Campinas, Piracicaba, Sao Paulo, Brazil
| | - Deborah Q Freitas
- Department of Oral Diagnosis, Area of Oral Radiology, Piracicaba Dental School, University of Campinas, Piracicaba, Sao Paulo, Brazil
| |
Collapse
|
37
|
Kamburoğlu K, Yılmaz F, Yeta EN, Özen D. Assessment of furcal perforations in the vicinity of different root canal sealers using a cone beam computed tomography system with and without the application of artifact reduction mode: an ex vivo investigation on extracted human teeth. Oral Surg Oral Med Oral Pathol Oral Radiol 2016; 121:657-65. [DOI: 10.1016/j.oooo.2016.01.010] [Citation(s) in RCA: 10] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/21/2015] [Revised: 11/28/2015] [Accepted: 01/14/2016] [Indexed: 11/26/2022]
|
38
|
Soft tissue coverage on the segmentation accuracy of the 3D surface-rendered model from cone-beam CT. Clin Oral Investig 2016; 21:921-930. [PMID: 27206862 PMCID: PMC5360826 DOI: 10.1007/s00784-016-1844-x] [Citation(s) in RCA: 8] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/06/2015] [Accepted: 05/02/2016] [Indexed: 10/25/2022]
Abstract
OBJECTIVES The aim of this study is to investigate the effect of soft tissue presence on the segmentation accuracy of the 3D hard tissue models from cone-beam computed tomography (CBCT). MATERIALS AND METHODS Seven pairs of CBCT Digital Imaging and Communication in Medicine (DICOM) datasets, containing data of human cadaver heads and their respective dry skulls, were used. The effect of the soft tissue presence on the accuracy of the segmented models was evaluated by performing linear and angular measurements and by superimposition and color mapping of the surface discrepancies after splitting the mandible and maxillo-facial complex in the midsagittal plane. RESULTS The linear and angular measurements showed significant differences for the more posterior transversal measurements on the mandible (p < 0.01). By splitting and superimposing the maxillo-facial complex, the mean root-mean-square error (RMSE) as a measurement of inaccuracy decreased insignificantly from 0.936 to 0.922 mm (p > 0.05). The RMSE value for the mandible, however, significantly decreased from 1.240 to 0.981 mm after splitting (p < 0.01). CONCLUSIONS The soft tissue presence seems to affect the accuracy of the 3D hard tissue model obtained from a cone-beam CT, below a generally accepted level of clinical significance of 1 mm. However, this level of accuracy may not meet the requirement for applications where high precision is paramount. CLINICAL RELEVANCE Accuracy of CBCT-based 3D surface-rendered models, especially of the hard tissues, are crucial in several dental and medical applications, such as implant planning and virtual surgical planning on patients undergoing orthognathic and navigational surgeries. When used in applications where high precision is paramount, the effect of soft tissue presence should be taken into consideration during the segmentation process.
Collapse
|
39
|
Kühl S, Zürcher S, Zitzmann NU, Filippi A, Payer M, Dagassan-Berndt D. Detection of peri-implant bone defects with different radiographic techniques - a human cadaver study. Clin Oral Implants Res 2015; 27:529-34. [PMID: 26059443 DOI: 10.1111/clr.12619] [Citation(s) in RCA: 38] [Impact Index Per Article: 4.2] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Accepted: 04/25/2015] [Indexed: 01/03/2023]
Abstract
OBJECTIVES Two- and three-dimensional radiographic techniques are available to determine peri-implantitis-related bone loss around dental implants. PURPOSE To compare the performance of detecting different peri-implant bone defects in intraoral radiography (IR), panoramic radiography (PR), Cone Beam Computer Tomography (CBCT) and Computer Tomography (CT). MATERIAL AND METHODS Six implants were inserted under ideal conditions into the lower jaw of an edentulous human cadaver. IR, PR, CBCT and CT were performed. Two-wall, three-wall and four-wall defects with 1 mm depth were artificially created around two of the implants (one anterior and one posterior), and radiographies were repeated. The identical set-up was used for 3-mm-deep bone defects. All images were presented to seven observers. Sensitivity (SN) and specificity (SP) were determined for each modality, defect type and depths, and likelihood ratios were calculated. RESULTS The highest sensitivity was found with IR and CBCT for 1 mm (0.67; 0.68) and 3-mm defects (0.81; 0.79). The highest specificity was found with IR for both defect depths (0.51). The best classification of defect type revealed PR for both 1-mm and 3-mm-deep defects. Both likelihood ratios (LR+ and LR-) were best for IR with 1-mm (1.37 and 0.65) and with 3-mm defects (1.65 and 0.37). CONCLUSIONS IR should still be recommended as favourable method evaluating bone loss around dental implants, while CT demonstrated the lowest performance in detecting peri-implant bone defects.
Collapse
Affiliation(s)
- Sebastian Kühl
- Department of Oral Surgery, Oral Radiology and Oral Medicine, School of Dental Medicine University of Basel, Basel, Switzerland
| | - Silvia Zürcher
- Department of Oral Surgery, Oral Radiology and Oral Medicine, School of Dental Medicine University of Basel, Basel, Switzerland
| | - Nicola U Zitzmann
- Clinic for Periodontology, Endodontics and Cariology, University of Basel, Basel, Switzerland
| | - Andreas Filippi
- Department of Oral Surgery, Oral Radiology and Oral Medicine, School of Dental Medicine University of Basel, Basel, Switzerland
| | - Michael Payer
- Department of Oral Surgery and Radiology, Medical University of Graz, Graz, Austria
| | - Dorothea Dagassan-Berndt
- Department of Oral Surgery, Oral Radiology and Oral Medicine, School of Dental Medicine University of Basel, Basel, Switzerland
| |
Collapse
|
40
|
Benic GI, Elmasry M, Hämmerle CHF. Novel digital imaging techniques to assess the outcome in oral rehabilitation with dental implants: a narrative review. Clin Oral Implants Res 2015; 26 Suppl 11:86-96. [DOI: 10.1111/clr.12616] [Citation(s) in RCA: 47] [Impact Index Per Article: 5.2] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Accepted: 04/16/2015] [Indexed: 11/26/2022]
Affiliation(s)
- Goran I. Benic
- Clinic of Fixed and Removable Prosthodontics and Dental Material Science; Center of Dental Medicine; University of Zurich; Zurich Switzerland
| | - Moustafa Elmasry
- Clinic of Fixed and Removable Prosthodontics and Dental Material Science; Center of Dental Medicine; University of Zurich; Zurich Switzerland
| | - Christoph H. F. Hämmerle
- Clinic of Fixed and Removable Prosthodontics and Dental Material Science; Center of Dental Medicine; University of Zurich; Zurich Switzerland
| |
Collapse
|
41
|
Slagter KW, Raghoebar GM, Vissink A, Meijer HJA. Inter- and intraobserver reproducibility of buccal bone measurements at dental implants with cone beam computed tomography in the esthetic region. Int J Implant Dent 2015; 1:8. [PMID: 27747630 PMCID: PMC5005615 DOI: 10.1186/s40729-015-0007-1] [Citation(s) in RCA: 9] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/24/2014] [Accepted: 02/19/2015] [Indexed: 11/10/2022] Open
Abstract
BACKGROUND Sufficient buccal bone is important for optimal esthetic results of implant treatment in the anterior region. It can be measured with cone beam computed tomography (CBCT), but background scattering and problems with standardization of the measurements are encountered. The aim was to develop a method for reliable, reproducible measurements on CBCTs. METHODS Using a new method, buccal bone thickness was measured on ten CBCTs at six positions along the implant axis. Inter- and intraobserver reproducibility was assessed by repeated measurements by two examiners. RESULTS Mean buccal bone thickness measured by observers 1 and 2 was 2.42 mm (sd: 0.50) and 2.41 mm (sd: 0.47), respectively. Interobserver intraclass correlation coefficient was 0.96 (95% CI 0.93 to 0.98). The mean buccal bone thickness of the first measurement and the second measurement of observer 1 was 2.42 mm (sd: 0.50) and 2.53 mm (sd: 0.49), respectively, with an intraobserver intraclass correlation coefficient of 0.93 (95% CI 0.88 to 0.96). The mean buccal bone thickness of the first measurement and the second measurement of observer 2 was 2.41 mm (sd: 0.47) and 2.52 mm (sd: 0.47), respectively, with an intraobserver intraclass correlation coefficient of 0.96 (95% CI 0.93 to 0.97). CONCLUSIONS Applying the methods used in this study, CBCTs are suitable for reliable and reproducible measurements of buccal bone thickness at implants.
Collapse
Affiliation(s)
- Kirsten W Slagter
- Department of Oral and Maxillofacial Surgery, University of Groningen, University Medical Center Groningen, PO Box 30.001, 9700RB, Groningen, The Netherlands
| | - Gerry M Raghoebar
- Department of Oral and Maxillofacial Surgery, University of Groningen, University Medical Center Groningen, PO Box 30.001, 9700RB, Groningen, The Netherlands
| | - Arjan Vissink
- Department of Oral and Maxillofacial Surgery, University of Groningen, University Medical Center Groningen, PO Box 30.001, 9700RB, Groningen, The Netherlands
| | - Henny J A Meijer
- Department of Oral and Maxillofacial Surgery, University of Groningen, University Medical Center Groningen, PO Box 30.001, 9700RB, Groningen, The Netherlands. .,Department of Fixed and Removable Prosthodontics, University of Groningen, University Medical Center Groningen, PO Box 30.001, 9700RB, Groningen, The Netherlands.
| |
Collapse
|
42
|
Bezerra ISQ, Neves FS, Vasconcelos TV, Ambrosano GMB, Freitas DQ. Influence of the artefact reduction algorithm of Picasso Trio CBCT system on the diagnosis of vertical root fractures in teeth with metal posts. Dentomaxillofac Radiol 2015; 44:20140428. [PMID: 25764360 DOI: 10.1259/dmfr.20140428] [Citation(s) in RCA: 58] [Impact Index Per Article: 6.4] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/31/2022] Open
Abstract
OBJECTIVES To assess the influence of the artefact reduction algorithm (AR) available on the Picasso Trio 3D(®) imaging system (Vatech, Hwaseong, Republic of Korea) on image quality [greyscale values, contrast-to-noise ratio (CNR) and artefact formation] and diagnosis of vertical root fractures (VRFs) in the teeth with intracanal metal posts. METHODS 30 uniradicular teeth had their crowns removed and their roots endodontically treated to receive intracanal metal posts. In 20 teeth, both complete (n = 10) and incomplete (n = 10) VRFs were created. Each tooth was scanned twice, with and without AR activation. The mean and variation of greyscale values, as well as CNR, were calculated for all images. Subsequently, an evaluator compared the amount of artefact (cupping, white streaks and dark bands) in all images. Five evaluators rated for VRF presence using a five-point scale. RESULTS Mean greyscale values and CNR were significantly decreased in images acquired with the AR. The usage of the algorithm promoted an overall reduction of image artefacts. Regarding the diagnosis of complete and incomplete VRFs, the use of the AR had an overall negative impact on specificity and accuracy. CONCLUSIONS While indeed reducing artefact formation, the use of the AR, instead of improving the impact on the diagnosis of VRFs in teeth with intracanal metal posts, had a negative impact on the diagnosis.
Collapse
Affiliation(s)
- I S Q Bezerra
- 1 Oral Radiology Area, Department of Oral Diagnosis, Piracicaba Dental School, State University of Campinas, Piracicaba, São Paulo, Brazil
| | - F S Neves
- 1 Oral Radiology Area, Department of Oral Diagnosis, Piracicaba Dental School, State University of Campinas, Piracicaba, São Paulo, Brazil
| | - T V Vasconcelos
- 1 Oral Radiology Area, Department of Oral Diagnosis, Piracicaba Dental School, State University of Campinas, Piracicaba, São Paulo, Brazil
| | - G M B Ambrosano
- 2 Department of Community Dentistry, Dental School of Piracicaba, State University of Campinas, Piracicaba, São Paulo, Brazil
| | - D Q Freitas
- 1 Oral Radiology Area, Department of Oral Diagnosis, Piracicaba Dental School, State University of Campinas, Piracicaba, São Paulo, Brazil
| |
Collapse
|