1
|
Braga MS, de Almeida Ramos AM, Coelho-Silva F, Bonadiman EA, Pereira TCR, de-Azevedo-Vaz SL. Impact of enhancement filters of a CMOS system on halo artifact expression at the bone-to-implant interface. Clin Oral Investig 2024; 28:161. [PMID: 38381269 DOI: 10.1007/s00784-024-05553-1] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/09/2023] [Accepted: 02/10/2024] [Indexed: 02/22/2024]
Abstract
OBJECTIVE To assess the impact of enhancement filters on the formation of halo artifacts in radiographs of dental implants obtained with a complementary metal oxide semiconductor (CMOS) system. METHODS Digital radiographs of dental implants placed in dry human mandibles were processed with the Noise Reduction smoothing filter, as well as the Sharpen 1, Sharpen 4, and Sharpen UM high-pass filters available in the CLINIVIEW™ software (Instrumentarium Dental, Tuusula, Finland). Subjective analysis involved evaluating the left, right, and apical surfaces of each implant for the presence of much, few, or no halo. The objective analysis involved measurement of the halo area using the Trainable Weka Segmentation plugin (ImageJ, National Institutes of Health, Bethesda, MD, USA). Data were analyzed using Friedman's test (subjective analysis) and ANOVA (objective analysis) (α = 5%). RESULTS In the subjective evaluation, the Sharpen 4 filter produced more radiographs with much halo present, and in the objective evaluation, a bigger halo area when compared to the original images and the Noise Reduction filter for all surfaces (p < 0.05). CONCLUSIONS When evaluating dental implants, priority should be given to original images and those enhanced with smoothing filters since they exhibit fewer halo artifacts. CLINICAL RELEVANCE Post-processing tools, such as enhancement filters, may improve the image quality and assist some diagnostic tasks. However, little is known regarding the impact of enhancement filters in halo formation on CMOS systems, which have been increasingly used in dental offices.
Collapse
Affiliation(s)
| | | | - Fernanda Coelho-Silva
- Department of Oral Diagnosis, Division of Oral Radiology, Piracicaba Dental School, University of Campinas, Piracicaba, Brazil
| | - Eduarda Alberti Bonadiman
- Dental Sciences Graduate Program, Federal University of Espírito Santo (UFES), Av. Marechal Campos 1468, Maruípe, Vitória, Espírito Santo, 29043900, Brazil
| | | | - Sergio Lins de-Azevedo-Vaz
- Dental Sciences Graduate Program, Federal University of Espírito Santo (UFES), Av. Marechal Campos 1468, Maruípe, Vitória, Espírito Santo, 29043900, Brazil.
| |
Collapse
|
2
|
Miranda-Viana M, Fontenele RC, Nogueira-Reis F, Farias-Gomes A, Oliveira ML, Freitas DQ, Haiter-Neto F. DICOM file format has better radiographic image quality than other file formats: an objective study. Braz Dent J 2023; 34:150-157. [PMID: 37909638 PMCID: PMC10642272 DOI: 10.1590/0103-6440202305499] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/28/2023] [Accepted: 07/24/2023] [Indexed: 11/03/2023] Open
Abstract
This study aimed to assess the influence of the file format on the image quality parameters (image noise, brightness, and uniformity) of periapical radiographs acquired with different digital systems. Radiographic images of an acrylic phantom were acquired with two digital systems - Digora Toto and Express, and exported into five different file formats - TIFF, BMP, DICOM, PNG, and JPEG. Image noise, image brightness (mean of gray values), and image uniformity (standard deviation of gray values) were evaluated in all images. A two-way analysis of variance with Tukey's test as a post-hoc test was used to compare the results, considering the file formats and radiographic systems as the studied factors. A significance level of 5% was adopted for all analyses. The DICOM image file format presented lower image noise, higher brightness (higher mean gray values), and greater image uniformity (p<0.001) than the other file formats, which did not differ from each other for both digital radiography systems (p>0.05). The Express system revealed lower image noise and greater image uniformity than the Digora Toto system regardless of the image file format (p<0.001). Moreover, the Express showed higher brightness than the Digora Toto for all image file formats (p<0.001), except for the DICOM image file format, which did not significantly differ between the digital radiography systems tested (p>0.05). The DICOM image file format showed lower image noise, higher brightness, and greater image uniformity than the other file formats (TIFF, BMP, PNG, and JPEG) in both digital radiography systems tested.
Collapse
Affiliation(s)
- Murilo Miranda-Viana
- Department of Oral Diagnosis - Oral Radiology Area, Piracicaba Dental School, University of Campinas, Piracicaba, SP, Brazil
| | - Rocharles Cavalcante Fontenele
- Department of Oral Diagnosis - Oral Radiology Area, Piracicaba Dental School, University of Campinas, Piracicaba, SP, Brazil
| | - Fernanda Nogueira-Reis
- Department of Oral Diagnosis - Oral Radiology Area, Piracicaba Dental School, University of Campinas, Piracicaba, SP, Brazil
| | - Amanda Farias-Gomes
- Oral Radiology Area, Dental School, Federal University of Mato Grosso do Sul, Campo Grande, MS, Brazil
| | - Matheus L Oliveira
- Department of Oral Diagnosis - Oral Radiology Area, Piracicaba Dental School, University of Campinas, Piracicaba, SP, Brazil
| | - Deborah Queiroz Freitas
- Department of Oral Diagnosis - Oral Radiology Area, Piracicaba Dental School, University of Campinas, Piracicaba, SP, Brazil
| | - Francisco Haiter-Neto
- Department of Oral Diagnosis - Oral Radiology Area, Piracicaba Dental School, University of Campinas, Piracicaba, SP, Brazil
| |
Collapse
|
3
|
Ruiz DC, Gomes AF, Fontenele RC, Haiter Neto F, Freitas DQ, Groppo FC. Could the radiographic image quality be affected by the excessive use of the photostimulable phosphor plate? Braz Dent J 2023; 34:39-44. [PMID: 36888843 PMCID: PMC10027106 DOI: 10.1590/0103-6440202305225] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/29/2022] [Accepted: 01/18/2023] [Indexed: 03/08/2023] Open
Abstract
The study aimed to assess the influence of excessive use of a photostimulable phosphor plate (PSP) on the density, image noise, and contrast of radiographs. For that, radiographs of an acrylic block were acquired with a PSP of the Express intraoral system to assess the density and image noise. Initially, five images were obtained and exported (first group). After 400 exposures to X-rays and scannings of PSP, other five images were obtained and exported (second group). The same procedure was done after 800 (third group), 1200 (fourth group), 1600 (fifth group), and 2000 acquisitions (sixth group), resulting in 30 images to be evaluated. The mean and standard deviation of the gray values were calculated for the images using the ImageJ software. For contrast analysis, radiographs of an aluminum step-wedge were acquired with a new PSP following the same acquisition intervals. The percentage of contrast variation was calculated. Another two unused PSP receptors were employed to evaluate the method's reproducibility. The comparison of the results among the acquisition groups was performed with one-way Analysis of Variance (α=0.05). Intraclass Correlation Coefficient (ICC) assessed the reproducibility of the receptors. Image noise did not differ among the groups (p>0.05). There was a slight increase in density after 400 acquisitions and a slight difference in contrast for all acquisition groups without a pattern of increase or decrease (p<0.05). ICC showed excellent reliability for the methods. Therefore, excessive PSP use slightly affected the radiograph's density and contrast.
Collapse
Affiliation(s)
- Débora Costa Ruiz
- Department of Oral Diagnosis, Piracicaba Dental School, University of Campinas, Piracicaba, SP, Brazil
| | - Amanda Farias Gomes
- Department of Oral Diagnosis, Piracicaba Dental School, University of Campinas, Piracicaba, SP, Brazil
| | | | - Francisco Haiter Neto
- Department of Oral Diagnosis, Piracicaba Dental School, University of Campinas, Piracicaba, SP, Brazil
| | - Deborah Queiroz Freitas
- Department of Oral Diagnosis, Piracicaba Dental School, University of Campinas, Piracicaba, SP, Brazil
| | - Francisco Carlos Groppo
- Department of Oral Diagnosis, Piracicaba Dental School, University of Campinas, Piracicaba, SP, Brazil
- Department of Physiological Sciences, Piracicaba Dental School, University of Campinas, Piracicaba, SP, Brazil
| |
Collapse
|
4
|
Ruiz DC, Farias-Gomes A, Fontenele RC, Gaêta-Araujo H, Haiter-Neto F, Freitas DQ, Groppo FC. Influence of extensive use of a photostimulable phosphor receptor on the diagnosis of proximal carious lesions: An in vitro study. Oral Surg Oral Med Oral Pathol Oral Radiol 2022; 135:539-547. [PMID: 36566136 DOI: 10.1016/j.oooo.2022.11.004] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/16/2022] [Revised: 10/17/2022] [Accepted: 11/02/2022] [Indexed: 11/13/2022]
Abstract
OBJECTIVE The aim of this study was to evaluate the influence of the extensive use of a photostimulable phosphor (PSP) receptor on the diagnosis of proximal carious lesions. STUDY DESIGN Forty posterior teeth were paired and mounted in 20 phantoms. Using a PSP receptor of the Express intraoral system, 1 radiograph of each phantom was acquired, totaling 20 radiographs (group 1). After 400 acquisitions, another radiograph of each phantom was obtained, totaling 20 new radiographs (group 2). This procedure was also done after 800 (group 3), 1,200 (group 4), and 1,600 (group 5) acquisitions, resulting in 100 radiographs. Another 40 radiographs (20 phantoms × 2 groups) were obtained with a second PSP sensor to evaluate the diagnostic replicability of the receptors. All 140 radiographs were assessed independently by 5 examiners for the presence of proximal caries. Area under the receiver operating characteristic curve, sensitivity, and specificity were calculated and compared among the groups by analysis of variance. The Student t test evaluated the diagnostic replicability of the receptors. The significance level was set at 5% (P < .05). RESULTS The diagnostic outcomes for proximal caries did not differ among the groups (P ≥ .37). The diagnostic values did not differ among the radiographs acquired with the 2 PSP receptors (P ≥ .75). CONCLUSIONS The diagnosis of proximal carious lesions was not affected by extensive use of the PSP receptor.
Collapse
Affiliation(s)
- Débora Costa Ruiz
- Department of Oral Diagnosis, Piracicaba Dental School, University of Campinas, Piracicaba, São Paulo, Brazil.
| | - Amanda Farias-Gomes
- Department of Oral Diagnosis, Piracicaba Dental School, University of Campinas, Piracicaba, São Paulo, Brazil
| | | | - Hugo Gaêta-Araujo
- School of Dentistry, Federal University of Alfenas, Alfenas, Minas Gerais, Brazil
| | - Francisco Haiter-Neto
- Department of Oral Diagnosis, Piracicaba Dental School, University of Campinas, Piracicaba, São Paulo, Brazil
| | - Deborah Queiroz Freitas
- Department of Oral Diagnosis, Piracicaba Dental School, University of Campinas, Piracicaba, São Paulo, Brazil
| | - Francisco Carlos Groppo
- Department of Oral Diagnosis, Piracicaba Dental School, University of Campinas, Piracicaba, São Paulo, Brazil; Department of Physiological Sciences, Piracicaba Dental School, University of Campinas, Piracicaba, São Paulo, Brazil
| |
Collapse
|
5
|
SOUZA-PINTO GND, NEJAIM Y, GOMES AF, CANTERAS FB, FREITAS DQ, HAITER-NETO F. Evaluation of the microstructure, chemical composition, and image quality of different PSP receptors. Braz Oral Res 2022; 36:e130. [DOI: 10.1590/1807-3107bor-2022.vol36.0130] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/25/2021] [Accepted: 05/02/2022] [Indexed: 12/23/2022] Open
Affiliation(s)
| | - Yuri NEJAIM
- Universidade Federal do Mato Grosso do Sul, Brazil
| | | | | | | | | |
Collapse
|
6
|
Miranda-Viana M, Fontenele RC, Farias Gomes A, Nogueira-Reis F, Nejaim Y, Oliveira ML, Freitas DQ. Digital file format does not influence the radiographic diagnosis of vertical root fracture. Oral Radiol 2022; 38:452-458. [PMID: 34626307 PMCID: PMC8501329 DOI: 10.1007/s11282-021-00573-z] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/12/2021] [Accepted: 09/28/2021] [Indexed: 11/26/2022]
Abstract
OBJECTIVE To evaluate the influence of the file format of digital periapical radiographs on the diagnosis of vertical root fracture (VRF). STUDY DESIGN Periapical radiographic images of 34 single-rooted teeth-19 with VRF, and 15 without VRF were acquired using two digital systems-Digora Toto, and Digora Optime, and exported into four different file formats-TIFF, BMP, PNG, and JPEG, totaling 272 radiographs. The radiographs were assessed by five examiners for the detection of VRF, using a 5-point scale (1-definitely absent; 2-probably absent; 3-uncertain; 4-probably present; 5-definitely present). Diagnostic values of area under the ROC curve, specificity, and sensitivity for the diagnosis of VRF were calculated. The results were compared by two-way Analysis of Variance with post hoc Tukey's test. The intra- and inter-examiner agreements were measured by the Kappa test. The significance level was set at 5% for all analyses. RESULTS The values of intra-examiner agreement varied from moderate (0.56) to almost perfect (0.81), while the values of inter-examiner agreement varied from fair (0.29) to moderate (0.60). The image file format did not influence the diagnostic values for VRF for any of the radiographic systems tested (p > 0.05). Digora Toto had significantly greater values of area under the ROC curve than Digora Optime for all file formats (p = 0.001). CONCLUSION The image file format of periapical radiographs does not influence the diagnosis of VRF, regardless of the digital radiography system.
Collapse
Affiliation(s)
- Murilo Miranda-Viana
- Oral Radiology Area, Piracicaba Dental School, University of Campinas, Avenida Limeira, 901, Piracicaba, São Paulo, 13414-903, Brazil
| | - Rocharles Cavalcante Fontenele
- Oral Radiology Area, Piracicaba Dental School, University of Campinas, Avenida Limeira, 901, Piracicaba, São Paulo, 13414-903, Brazil.
| | - Amanda Farias Gomes
- Oral Radiology Area, Piracicaba Dental School, University of Campinas, Avenida Limeira, 901, Piracicaba, São Paulo, 13414-903, Brazil
| | - Fernanda Nogueira-Reis
- Oral Radiology Area, Piracicaba Dental School, University of Campinas, Avenida Limeira, 901, Piracicaba, São Paulo, 13414-903, Brazil
| | - Yuri Nejaim
- Oral Radiology Area, Dental School, Federal University of Mato Grosso do Sul, Campo Grande, MS, Brazil
| | - Matheus L Oliveira
- Oral Radiology Area, Piracicaba Dental School, University of Campinas, Avenida Limeira, 901, Piracicaba, São Paulo, 13414-903, Brazil
| | - Deborah Queiroz Freitas
- Oral Radiology Area, Piracicaba Dental School, University of Campinas, Avenida Limeira, 901, Piracicaba, São Paulo, 13414-903, Brazil
| |
Collapse
|
7
|
de Moura G, Vizzotto MB, Tiecher PFDS, Arús NA, da Silveira HLD. Benefits of using a photostimulable phosphor plate protective device. Dentomaxillofac Radiol 2021; 50:20200339. [PMID: 33411592 PMCID: PMC8404516 DOI: 10.1259/dmfr.20200339] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/16/2020] [Revised: 12/02/2020] [Accepted: 12/18/2020] [Indexed: 11/05/2022] Open
Abstract
OBJECTIVES To develop and test a protective device (PD) to increase the resistance of photostimulable storage phosphor (PSP) plate to compressive load, and assess the resulting image quality. METHODS Two prototypes, polyvinylchloride sheets of 0.3 mm and 0.7 mm each, were developed for PSP plate size 2. The resistance to compressive load was tested using eight new PSPs divided into four test groups: (1) PSP, (2) PSP and paperboard protector, (3) PSP and 0.3 mm PD, and (4) PSP and 0.7 mm PD. The resulting images were analyzed by three oral radiologists, based on the consensus for image artifacts. Additionally, the objective image quality test was performed with four new PSPs, using an 8-step wedge aluminum scale. The mean gray values and standard deviation were measured in a total of 240 images, and the data were analyzed using analysis of variance with Bonferroni post-hoc test. RESULTS Artifacts were seen in the PSP control group starting at 40 n, and at 150 n, 175 n and 300 n in 0.3 mm PD, paperboard protector and 0.7 mm PD, respectively. Although there was no statistical difference among groups, there were differences between exposure times (0.06-0.25 s, 0.06-0.40 s, and 0.10-0.40 s). Scanning resolution of 20 lp/mm showed higher mean gray value than 25 and 40 lp/mm (p < 0.05). CONCLUSION The developed PDs improved the PSP resistance to compressive forces, with low interference on the pixel gray values, regardless of exposure time and spatial resolution. Nevertheless, the 0.7 mm PD could withstand the maximum compressive load.
Collapse
Affiliation(s)
- Graziela de Moura
- Department of Oral Surgery and Orthopedics, Division of Oral Radiology, Dental School, Federal University of Rio Grande do Sul (UFRGS), Porto Alegre, Rio Grande do Sul, Brazil
| | - Mariana Boessio Vizzotto
- Department of Oral Surgery and Orthopedics, Division of Oral Radiology, Dental School, Federal University of Rio Grande do Sul (UFRGS), Porto Alegre, Rio Grande do Sul, Brazil
| | - Priscila Fernanda da Silveira Tiecher
- Department of Oral Surgery and Orthopedics, Division of Oral Radiology, Dental School, Federal University of Rio Grande do Sul (UFRGS), Porto Alegre, Rio Grande do Sul, Brazil
| | - Nádia Assein Arús
- Department of Oral Surgery and Orthopedics, Division of Oral Radiology, Dental School, Federal University of Rio Grande do Sul (UFRGS), Porto Alegre, Rio Grande do Sul, Brazil
| | - Heraldo Luis Dias da Silveira
- Department of Oral Surgery and Orthopedics, Division of Oral Radiology, Dental School, Federal University of Rio Grande do Sul (UFRGS), Porto Alegre, Rio Grande do Sul, Brazil
| |
Collapse
|
8
|
Miranda-Viana M, Madlum DV, Oliveira-Santos N, Gaêta-Araujo H, Haiter-Neto F, Oliveira ML. Influence of the image file format of digital periapical radiographs on the diagnosis of external and internal root resorptions. Clin Oral Investig 2021; 25:4941-4948. [PMID: 33495894 DOI: 10.1007/s00784-021-03803-0] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/30/2020] [Accepted: 01/19/2021] [Indexed: 11/28/2022]
Abstract
OBJECTIVES To evaluate the influence of different image file formats of digital radiographic images on the diagnosis of external (ERR) and internal root resorption (IRR). MATERIALS AND METHODS Thirty-four human teeth were selected. For ERR, 20 teeth were used (10 control and 10 with simulated ERR), and for IRR, 14 teeth were used (before and after IRR simulation). Digital periapical radiographs were acquired using the Digora Toto system and exported in four different image file formats: TIFF, BMP, PNG, and JPEG, totaling 192 radiographs. Five examiners evaluated the images using the JPEGView software and scored the detection of ERR or IRR on a 5-point scale. Sensitivity, specificity, accuracy, and the area under the ROC curve were obtained for the diagnosis of ERR and IRR in the different image file formats. Two-way ANOVA compared the diagnostic values between the file formats and the Kappa test assessed intra- and inter-examiner agreement. The significance level was set at 5% (α = 0.05). RESULTS The mean values of intra-examiner agreement were substantial (0.740) for ERR and almost perfect (0.836) for IRR and, inter-examiner was fair (0.263) and moderate (0.421), respectively. No statistically significant differences were found among the different file formats for the diagnostic values of ERR and IRR. CONCLUSION The file format of digital radiographs does not influence the diagnosis of ERR and IRR. CLINICAL RELEVANCE Digital radiographic images may be susceptible to computational factors; however, they can be stored in multiple file formats without affecting the diagnosis of dental root resorptions.
Collapse
Affiliation(s)
- Murilo Miranda-Viana
- Piracicaba Dental School, Department of Oral Diagnosis, University of Campinas, Avenida Limeira, 901, São Paulo, 13414-903, Piracicaba, Brazil.
| | - Daniela Verardi Madlum
- Piracicaba Dental School, Department of Oral Diagnosis, University of Campinas, Avenida Limeira, 901, São Paulo, 13414-903, Piracicaba, Brazil
| | - Nicolly Oliveira-Santos
- Piracicaba Dental School, Department of Oral Diagnosis, University of Campinas, Avenida Limeira, 901, São Paulo, 13414-903, Piracicaba, Brazil
| | - Hugo Gaêta-Araujo
- Piracicaba Dental School, Department of Oral Diagnosis, University of Campinas, Avenida Limeira, 901, São Paulo, 13414-903, Piracicaba, Brazil
| | - Francisco Haiter-Neto
- Piracicaba Dental School, Department of Oral Diagnosis, University of Campinas, Avenida Limeira, 901, São Paulo, 13414-903, Piracicaba, Brazil
| | - Matheus L Oliveira
- Piracicaba Dental School, Department of Oral Diagnosis, University of Campinas, Avenida Limeira, 901, São Paulo, 13414-903, Piracicaba, Brazil
| |
Collapse
|
9
|
Evaluation of Two Dental Digital Imaging Systems Based on Quality Scorings, Burn-Out Effects and Cervical Width Determination. BALKAN JOURNAL OF DENTAL MEDICINE 2020. [DOI: 10.2478/bjdm-2020-0012] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/21/2022] Open
Abstract
Summary
Background/Aim: The aim of the present study is to evaluate diagnostic accuracy of two generic image receptors with CMOS and PSP sensors for image quality scoring (IQS), burnout incidences (BI) and cervical widths (CW) with regard to four different exposure times.
Material and Methods: 43 incisor teeth within 15 paraffin block models were exposed at 4 different exposure times both for the CMOS and PSP groups, and a total number of 120 images were obtained. All images were evaluated by 3 dentomaxillofacial radiologists via 3 different criteria; IQS, BI, CW.
Results: Diagnostic quality scorings between groups displayed statistically significant difference for 0,1; 0,125 and 0,16 sec exposure times. PSP group revealed higher IQS. For 0,125 and 0,16 seconds exposure times, PSP group showed higher percentages of BI. Average CW were lower in PSP group. Although no statistically significant difference was found between average CW vs. exposure times in the CMOS group; PSP group revealed significant differences among exposure times. We can state that, the PSP system displayed higher image quality so exposure times can be reduced, alas, the same conclusion is not possible with CMOS system used.
Conclusions: Image quality perception is higher in PSP system we used, compared with CMOS system. PSP system display more burnout effects with increasing exposure times, while CMOS system is constant.
Collapse
|
10
|
Fontenele RC, Nejaim Y, Farias Gomes A, Gaêta-Araujo H, Haiter-Neto F, Freitas DQ. Does the addition of a lead foil to digital radiographic receptors influence image contrast and approximal caries lesions diagnosis? Dentomaxillofac Radiol 2020; 49:20190384. [DOI: 10.1259/dmfr.20190384] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/05/2022] Open
Abstract
Objectives: To access the influence of the addition of a lead foil to intraoral digital radiographic receptors on image contrast and approximal caries lesions diagnosis. Methods: 40 posterior teeth were distributed in silicone phantoms composed of two premolars, two molars and a non-test canine. Radiographic images of the phantoms were obtained with and without the incorporation of a lead foil, using the Digora Optime and Digora Toto systems. Four observers scored the images for the presence of caries lesions, using a 5-point scale. Images of an aluminum step wedge were acquired with and without the incorporation of a lead foil. Gray values and standard deviation of gray values were calculated in different thickness of the step wedge and, then, contrast variation was calculated. Results: Presence of a lead foil did not influence caries lesions diagnostic values, regardless of the type of digital system (p > 0.05). In general, the objective analysis was not influenced by the presence of a lead foil in any of the tested systems (p > 0.05). However, Digora Toto images showed greater gray values, lower standard deviation of gray values and lower contrast variation, regardless of the presence of the lead foil (p < 0.05). Conclusions: The addition of a lead foil to intraoral digital receptors did not influence image contrast nor caries lesions diagnosis.
Collapse
Affiliation(s)
| | - Yuri Nejaim
- Department of Oral Diagnosis, Piracicaba Dental School, State University of Campinas, Piracicaba, SP, Brazil
| | - Amanda Farias Gomes
- Department of Oral Diagnosis, Piracicaba Dental School, State University of Campinas, Piracicaba, SP, Brazil
| | - Hugo Gaêta-Araujo
- Department of Oral Diagnosis, Piracicaba Dental School, State University of Campinas, Piracicaba, SP, Brazil
| | - Francisco Haiter-Neto
- Department of Oral Diagnosis, Piracicaba Dental School, State University of Campinas, Piracicaba, SP, Brazil
| | - Deborah Queiroz Freitas
- Department of Oral Diagnosis, Piracicaba Dental School, State University of Campinas, Piracicaba, SP, Brazil
| |
Collapse
|
11
|
Digital subtraction radiography in detection of vertical root fractures: accuracy evaluation for root canal filling, fracture orientation and width variables. An ex-vivo study. Clin Oral Investig 2020; 24:3671-3681. [PMID: 32080760 DOI: 10.1007/s00784-020-03245-0] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/15/2019] [Accepted: 01/29/2020] [Indexed: 01/19/2023]
Abstract
OBJECTIVE Ex-vivo evaluation of the detectability of vertical root fractures (VRFs) using digital subtraction radiography (DSR) and conventional digital periapical radiography (CDPR); investigation of the effect of root canal filling, x-ray angulation, and thickness of the VRF in the diagnostic accuracy. MATERIALS AND METHODS Sixty root canals were mechanically prepared and radiographed either with a gutta-percha root canal filling or without, at 0o and ± 10o. VRFs were introduced with a universal testing machine. The width and angulation of the fracture line with the radiographic beam were calculated. DSR was performed comparing radiographs obtained prior to and after the VRF induction. Five examiners evaluated the resultant images and analysis was performed using receiver operator characteristic (ROC) statistics and binary logistic regression tests. RESULTS No significant differences in sensitivity, specificity, and the areas under the ROC curves (AUC) between the CDPR and DSR were detected (p > 0.05), except for root canal filled teeth where the AUC for DSR was higher (p < 0.05). Using DSR, a VRF was 1.3 times more likely to be diagnosed [95% confidence intervals (CI): 1.045-1.59; p = 0.018]. A correct diagnosis was 2.399 times more likely to occur in non-filled teeth regardless of the radiographic technique (95% CI 1.940-2.965; p = 0). The regression coefficients were positive for width and negative for angle. CONCLUSIONS DSR showed a better diagnostic accuracy of VRFs compared with CDPR, in single root canal filled teeth. The angulation, the width, and the presence of a root canal filling affected the diagnostic potential. CLINICAL RELEVANCE DSR is a cost- and time-effective imaging technique that could contribute in early diagnosis of VRFs.
Collapse
|