1
|
Lizcano JD, Marei S, Sharkey PF, Higuera-Rueda CA, Moskal JT, Clyburn TA, Suleiman LI, McGrory BJ. Does the Type of Femoral Stem and/or Femoral Head Influence the Rate of Adverse Local Tissue Reactions After Primary Total Hip Arthroplasty? J Arthroplasty 2024:S0883-5403(24)01066-0. [PMID: 39426440 DOI: 10.1016/j.arth.2024.10.051] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 09/18/2024] [Revised: 10/08/2024] [Accepted: 10/11/2024] [Indexed: 10/21/2024] Open
Affiliation(s)
- Juan D Lizcano
- Department of Orthopaedics Cleveland Clinic, Weston, Florida
| | - Sameh Marei
- Menoufia Orthopedic Surgery Department, Menoufia University Hospitals, Menoufia, Egypt
| | | | | | - Joseph T Moskal
- Department of Orthopaedics Carilion Clinic, Roanoke, Virginia
| | - Terry A Clyburn
- Department of Orthopaedics Houston Methodists, Houston, Texas
| | - Linda I Suleiman
- Department of Orthopaedics Northwestern Feinberg School of Medicine, Chicago, Illinois
| | - Brian J McGrory
- Department of Orthopaedics Tufts University School of Medicine, Boston, Massachusetts
| |
Collapse
|
2
|
Bunyoz KI, Tsikandylakis G, Mortensen K, Gromov K, Mohaddes M, Malchau H, Troelsen A. The size of the femoral head does not influence metal ion levels after metal-on-polyethylene total hip arthroplasty: a five-year report from a randomized controlled trial. Bone Joint J 2024; 106-B:31-37. [PMID: 38423094 DOI: 10.1302/0301-620x.106b3.bjj-2023-0795.r2] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 03/02/2024]
Abstract
Aims In metal-on-polyethylene (MoP) total hip arthroplasty (THA), large metal femoral heads have been used to increase stability and reduce the risk of dislocation. The increased size of the femoral head can, however, lead to increased taper corrosion, with the release of metal ions and adverse reactions. The aim of this study was to investigate the relationship between the size of the femoral head and the levels of metal ions in the blood in these patients. Methods A total of 96 patients were enrolled at two centres and randomized to undergo MoP THA using either a 32 mm metal head or a femoral head of between 36 mm and 44 mm in size, being the largest possible to fit the thinnest available polyethylene insert. The levels of metal ions and patient-reported outcome measures (Oxford Hip Score, University of California, Los Angeles Activity Scale) were recorded at two and five years postoperatively. Results At five years, the median levels of chromium, cobalt, and titanium were 0.5 μg/l (interquartile range (IQR) 0.50 to 0.62), 0.24 μg/l (IQR 0.18 to 0.30), and 1.16 μg/l (IQR 1.0 to 1.68) for the 32 mm group, and 0.5 μg/l (IQR 0.5 to 0.54), 0.23 μg/l (IQR 0.17 to 0.39), and 1.30 μg/l (IQR 1 to 2.05) for the 36 mm to 44 mm group, with no significant difference between the groups (p = 0.825, p = 1.000, p = 0.558). There were increased levels of metal ions at two years postoperatively in seven patients in the 32 mm group, compared with four in the 36 mm to 44 mm group, and at five years postoperatively in six patients in the 32 mm group, compared with seven in the 36 mm to 44 mm group. There was no significant difference in either the OHS (p = 0.665) or UCLA (p = 0.831) scores between patients with or without an increased level of metal ions. Conclusion In patients who underwent MoP THA, we found no differences in the levels of metal ions five years postoperatively between those with a femoral head of 32 mm and those with a femoral head of between 36 mm and 44 mm, and no corrosion-related revisions. As taper corrosion can start after five years, there remains a need for longer-term studies investigating the relationship between the size of the femoral head size and corrosion in patients undergoing MoP THA.
Collapse
Affiliation(s)
- Kristine I Bunyoz
- Department of Orthopaedic Surgery, Copenhagen University Hospital, Hvidovre, Denmark
| | - Georgios Tsikandylakis
- Department of Orthopaedics, Sahlgrenska University Hospital, Gothenburg, Sweden
- Department of Orthopaedics, Institute of Clinical Sciences, Sahlgrenska Academy, University of Gothenburg, Gothenburg, Sweden
| | - Kristian Mortensen
- Department of Orthopaedic Surgery, Copenhagen University Hospital, Hvidovre, Denmark
| | - Kirill Gromov
- Department of Orthopaedic Surgery, Copenhagen University Hospital, Hvidovre, Denmark
| | - Maziar Mohaddes
- Department of Orthopaedics, Sahlgrenska University Hospital, Gothenburg, Sweden
- Department of Orthopaedics, Institute of Clinical Sciences, Sahlgrenska Academy, University of Gothenburg, Gothenburg, Sweden
| | - Henrik Malchau
- Department of Orthopaedics, Institute of Clinical Sciences, Sahlgrenska Academy, University of Gothenburg, Gothenburg, Sweden
- Harris Orthopaedic Laboratory, Department of Orthopaedics, Massachusetts General Hospital, Boston, Massachusetts, USA
| | - Anders Troelsen
- Department of Orthopaedic Surgery, Copenhagen University Hospital, Hvidovre, Denmark
| |
Collapse
|
3
|
Bunyoz KI, Tsikandylakis G, Mortensen K, Gromov K, Mohaddes M, Malchau H, Troelsen A. No difference in whole-blood metal ions between 32-mm and 36- to 44-mm femoral heads in metal-on-polyethylene total hip arthroplasty: a 2-year report from a randomised control trial. Hip Int 2023; 33:184-192. [PMID: 34102902 DOI: 10.1177/11207000211022623] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 02/04/2023]
Abstract
AIM To investigate the effect of femoral head size on blood metal-ion levels caused by taper corrosion in metal-on-polyethylene total hip arthroplasty, comparing 36- to 44-mm heads with 32-mm heads. METHODS In a randomised, controlled, single-blinded trial, 96 patients were allocated to receive either a 32-mm metal head or the largest possible metal head (36-44 mm) that could be accommodated in the thinnest available vitamin E, cross-linked polyethylene insert. Blood metal ion levels were collected at 1- and 2-year follow-ups. RESULTS At 1-year, metal-ion levels did not differ between the groups. The median (interquartile range) blood-ion levels for the 32-mm versus the 36- to 44-mm group were 0.11 µg/L (0.08-0.15) versus 0.12 µg/L (0.08-0.22), p = 0.546, for cobalt, 0.50 µg/L (0.50-0.59) versus 0.50 µg/L (0.50-1.20), p = 0.059, for chromium and 1.58 µg/L (1.38-2.05) versus 1.48 µg/L (1.14-1.87), p = 0.385, for titanium. At 2 years, there was no difference either and the corresponding values were 0.15 µg/L (0.12-0.24) versus 0.18 µg/L (0.12-0.28), p = 0.682 for cobalt, 0.50 µg/L (0.50-0.50) versus 0.50 µg/L (0.50-0.57), p = 0.554, for chromium and 1.54 µg/L (1.16-1.87) versus 1.42 µg/L (1.01-1.72), p = 0.207 for titanium. CONCLUSIONS The use of the largest possible metal head (36-44 mm) compared to a 32-mm head in metal-on-polyethylene bearings does not appear to elevate blood metal-ion levels up to 2 years postoperatively. As taper corrosion is probably time-dependent, longer-term reports are needed to evaluate the association between large metal heads and blood metal ion levels.Trial registration: ClinicalTrials.gov (reg. ID NCT0231 6704).
Collapse
Affiliation(s)
- Kristine I Bunyoz
- Department of Orthopaedic Surgery, Copenhagen University Hospital, Hvidovre, Denmark
| | - Georgios Tsikandylakis
- Department of Orthopaedics, Sahlgrenska University Hospital, Gothenburg, Sweden.,Department of Orthopaedics, Institute of Clinical Sciences, Sahlgrenska Academy, University of Gothenburg, Sweden
| | - Kristian Mortensen
- Department of Orthopaedic Surgery, Copenhagen University Hospital, Hvidovre, Denmark
| | - Kirill Gromov
- Department of Orthopaedic Surgery, Copenhagen University Hospital, Hvidovre, Denmark
| | - Maziar Mohaddes
- Department of Orthopaedics, Sahlgrenska University Hospital, Gothenburg, Sweden.,Department of Orthopaedics, Institute of Clinical Sciences, Sahlgrenska Academy, University of Gothenburg, Sweden
| | - Henrik Malchau
- Department of Orthopaedics, Institute of Clinical Sciences, Sahlgrenska Academy, University of Gothenburg, Sweden.,Harris Orthopaedic Laboratory, Department of Orthopaedics, Massachusetts General Hospital, Boston, USA
| | - Anders Troelsen
- Department of Orthopaedic Surgery, Copenhagen University Hospital, Hvidovre, Denmark
| |
Collapse
|
4
|
Ishii S, Homma Y, Matsukawa T, Baba T, Kaneko K, Ishijima M. Blood cobalt ion level in patients with different sizes of cobalt/chrome femoral head with the Accolade TMZF stem. INTERNATIONAL ORTHOPAEDICS 2022; 46:2205-2212. [PMID: 35840813 DOI: 10.1007/s00264-022-05502-1] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 03/18/2022] [Accepted: 06/29/2022] [Indexed: 11/30/2022]
Abstract
BACKGROUND Corrosion of stem-cobalt/chromium (Co/Cr) head interface and subsequent systemic Co ion complication have been a clinical concern after total hip arthroplasty (THA). The aim of this study is to investigate correlation between type of femoral head and blood Co ion level. METHODS One hundred four patients with THA using accolade TMZF and Co/Cr femoral head (32-mm; 55 cases, 36-mm; 20 cases, dual mobility system (DM) with 22.2 or 28-mm inner head; 29 cases) participated in this study, and blood Co ion concentration test was performed in patients a minimum of four years after THA. RESULTS DM group was significantly older than 32-mm and 36-mm group (DM: 73.9 ± 4.6, 32-mm: 63.3 ± 8.5, 36-mm: 66.8 ± 10.5). The median (interquartile range) blood Co concentration of each group was 32-mm group 0.26 µg/L (0.69), 36-mm group; 0.21 µg/L (0.30); and DM group 0.21 µg/L (0.13). There was a significant difference of Co concentration between DM and 32-mm group (p = 0.023). Abnormal values of the blood Co concentration (> 1 µg/L) were observed in the 32-mm group; 12 cases (21.8%), 36-mm group; 2 cases (10.0%); and DM group; 0 case (0%) (p = 0.018). CONCLUSIONS Co blood concentration differed among the different sizes of Co/Cr femoral head. THA using DM is a safe option with low risk of complication from cobalt ion if it is used for elderly patients.
Collapse
Affiliation(s)
- Seiya Ishii
- Department of Orthopaedic Surgery, Juntendo University Faculty of Medicine, 2-1-1 Hongo, Bunkyo-ku, Tokyo, 113-0033, Japan
| | - Yasuhiro Homma
- Department of Orthopaedic Surgery, Juntendo University Faculty of Medicine, 2-1-1 Hongo, Bunkyo-ku, Tokyo, 113-0033, Japan.
| | - Takehisa Matsukawa
- Department of Epidemiology and Environmental Health, Juntendo University Faculty of Medicine, 2-1-1 Hongo, Bunkyo-ku, Tokyo, 113-8421, Japan
- Department of Forensic Medicine, Juntendo University Faculty of Medicine, 2-1-1 Hongo, Bunkyo-ku, Tokyo, 113-8421, Japan
| | - Tomonori Baba
- Department of Orthopaedic Surgery, Juntendo University Faculty of Medicine, 2-1-1 Hongo, Bunkyo-ku, Tokyo, 113-0033, Japan
| | - Kazuo Kaneko
- Department of Orthopaedic Surgery, Juntendo University Faculty of Medicine, 2-1-1 Hongo, Bunkyo-ku, Tokyo, 113-0033, Japan
| | - Muneaki Ishijima
- Department of Orthopaedic Surgery, Juntendo University Faculty of Medicine, 2-1-1 Hongo, Bunkyo-ku, Tokyo, 113-0033, Japan
| |
Collapse
|
5
|
Haddad FS. Unexpected benefits of arthroplasty. Bone Joint J 2022; 104-B:309-310. [PMID: 35227096 DOI: 10.1302/0301-620x.104b3.bjj-2022-0115] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 11/05/2022]
Affiliation(s)
- Fares S Haddad
- University College London Hospitals, The Princess Grace Hospital, and The NIHR Biomedical Research Centre at UCLH, London, UK.,The Bone & Joint Journal, London, UK
| |
Collapse
|
6
|
Course of Metal Ions after a Revision of Malfunctioning Metal-on-Metal Total Hip Prostheses. ACTA ACUST UNITED AC 2021; 57:medicina57020115. [PMID: 33525335 PMCID: PMC7912175 DOI: 10.3390/medicina57020115] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/22/2020] [Revised: 01/25/2021] [Accepted: 01/26/2021] [Indexed: 12/16/2022]
Abstract
The present research evaluated the course of cobalt and chromium in the blood and urine after the revision of metal-on-metal with a ceramic-on-polyethylene total hip arthroplasty. Seven patients were enrolled for hip prosthesis revision owing to ascertained damage of the implant. Metals in the blood and urine were evaluated before and after the hip revision. The double measurement before the total hip revision revealed high levels of metal ions (on average, 88.1 µg/L of cobalt in the blood, 399.0 µg/g of creatinine cobalt in the urine, 46.8 µg/L of chromium in the blood, and 129.6 µg/g of creatinine chromium in the urine at the first measurements), with an increasing trend between the first and second dosage. Within a week after the hip revision, the levels of metal ions significantly decreased by approximately half. Four to six months after the operation, the cobalt levels were found near to the reference values, whereas the chromium levels reached 25% of the values measured before the revision. The revision of malfunctioning metal-on-metal implants produced a dramatic decrease of metal ions in biological fluids, although it did not completely rescue the chromium level.
Collapse
|