1
|
Thuan MD, Dung NQ. Results of Total Hip Replacement Surgery Using Short-Stem Spiron Prosthesis in Vietnamese Adults. Adv Orthop 2024; 2024:4623071. [PMID: 39015203 PMCID: PMC11251800 DOI: 10.1155/2024/4623071] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 12/16/2023] [Revised: 05/28/2024] [Accepted: 06/28/2024] [Indexed: 07/18/2024] Open
Abstract
Introduction Total hip arthroplasty with traditional stem joints, although bringing many benefits to patients indicated for hip replacement, faces many difficulties in reoperations in young patients due to the limited lifespan of the artificial joint. Recently, the short-stem joint was introduced to help overcome this problem. This study aims to evaluate the results of short-stem implants for primary total hip arthroplasty in Vietnamese adults. Materials and Methods The study design is retrospective longitudinal. The study subjects were 91 patients with aseptic necrosis of the femoral head who underwent short-shaft cementless total hip replacement surgery from February 2012 to December 2018. Outcomes that were assessed included implant survivorship, Harris hip scores, thigh pain, periprosthetic fracture, subsidence, proximal stress shielding, the prevalence of stem malalignment, and inappropriate implant sizing. Results Our research group has 119 hips of 91 patients (28 patients had hip replacements on both sides), with the average follow-up time of 67.1 months. Seven cases of early joint loosening required replacing the traditional stem. The survival rate is 94.1%. The average Harris hip score 24 months after surgery was statistically significantly higher than before (92.00 ± 4.47 and 45.56 ± 3.22, respectively, p < 0.001). The average leg length discrepancy between the two limbs before surgery was 9.5 ±mm and 24 months after surgery was 3.4 ± 2.9 mm. There were 12 cases (10.1%) of partial bone loss around the femoral stem; 12 cases of joint displacement of more than 2 mm, accounting for 10.1%; and 1 case of acetabular fracture, accounting for 0.8%. Conclusion The Spiron short stem has certain advantages suitable for young patients, restoring the hip anatomy and significantly improving postoperative hip function. However, this is a complex technique that needs to be performed by experienced surgeons who have practiced for a long time. We encourage using the short-stem implant during primary total hip arthroplasty in Vietnamese adult patients.
Collapse
Affiliation(s)
- Mai Duc Thuan
- Department of Joint SurgeryInstitute of Trauma and Orthopedic – 108 Military Central Hospital, Hanoi, Vietnam
| | - Nguyen Quoc Dung
- Department of Joint SurgeryInstitute of Trauma and Orthopedic – 108 Military Central Hospital, Hanoi, Vietnam
| |
Collapse
|
2
|
Hinz N, Marsoni G, Mittelstädt H, Sonnabend F, Wallroth K, Johl C, Weigert U, Anderl C, Ortmaier R, Zeleny N, Schulz AP. Short stem hip arthroplasty with the optimys prosthesis is a safe and effective option for obese patients: a mid-term follow-up multicenter study. Arch Orthop Trauma Surg 2024; 144:1401-1414. [PMID: 37924371 PMCID: PMC10896938 DOI: 10.1007/s00402-023-05105-4] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 06/02/2023] [Accepted: 10/09/2023] [Indexed: 11/06/2023]
Abstract
INTRODUCTION Short stems are a valuable option in young patients undergoing total hip arthroplasty (THA) because of their bone stock preserving properties facilitating revision hip arthroplasty. Although the effect of obesity on conventional THA is well studied, data about short stem THA in obese patients are lacking. Therefore, this study aimed to investigate the influence of obesity on complications, revisions, and outcome after short stem THA. MATERIALS AND METHODS This multicenter, observational cohort study included patients undergoing short stem THA with the optimys prosthesis. Follow-up examinations were performed at specific intervals up to 7 years postoperatively. Operation characteristics, general and specific complications, revisions, VAS rest pain, VAS load pain, VAS patient satisfaction, and Harris Hip Score (HHS) were recorded and statistically compared between obese (BMI ≥ 30 kg/m2) and non-obese (BMI < 30 kg/m2) patients. RESULTS Of the 224 patients included with a mean follow-up of 87.2 months (range 81.9-104.0), 69 were assigned to the OB group and 155 to the non-OB group. A minimally invasive approach was significantly less often selected in obese patients (p = 0.049), whereas operating time and length of hospital stay were not significantly different. The rate of general and specific complications did not significantly differ between both groups. Survival of the optimys prosthesis was 99.1% at 7-year follow-up and one patient per group had to undergo revision surgery. VAS rest pain, load pain, and satisfaction improved from preoperatively to postoperatively in both groups without a significant difference between both groups. While the HHS was improved from preoperatively to postoperatively, obese patients showed a significantly lower HHS at the 7-year follow-up (p = 0.01) but still exhibited an excellent scoring above the PASS threshold. CONCLUSION Short stem THA with the optimys prosthesis is a safe and effective option also in obese patients with an excellent clinical outcome and a low complication rate.
Collapse
Affiliation(s)
- Nico Hinz
- BG Hospital Hamburg, Trauma Surgery, Orthopedics and Sports Traumatology, Bergedorfer Strasse 10, 21033, Hamburg, Germany.
| | - Giulia Marsoni
- Erzgebirgsklinikum, Orthopedics and Trauma Surgery, Jahnsdorfer Strasse 7, 09366, Stollberg, Germany
| | - Hagen Mittelstädt
- University Medical Center Schleswig-Holstein, Campus Lübeck, Orthopaedic and Trauma Surgery, Ratzeburger Allee 160, 23538, Lübeck, Germany
| | - Falk Sonnabend
- Helios Klinik Köthen, Orthopedics, Hallesche Strasse 29, 06366, Köthen, Germany
| | - Karsten Wallroth
- Erzgebirgsklinikum, Orthopedics and Trauma Surgery, Jahnsdorfer Strasse 7, 09366, Stollberg, Germany
| | - Carsten Johl
- Klinikum Dahme-Spreewald, Orthopedics and Trauma Surgery, Schillerstrasse 29, 15907, Lübben, Germany
| | - Ulrich Weigert
- Practice for Orthopedics and Trauma Surgery, Friedrichstrasse 1-3, 15537, Erkner, Germany
| | - Conrad Anderl
- Ordensklinikum Linz Barmherzige Schwestern, Orthopedics, Seilerstätte 4, 4010, Linz, Austria
| | - Reinhold Ortmaier
- Ordensklinikum Linz Barmherzige Schwestern, Orthopedics, Seilerstätte 4, 4010, Linz, Austria
| | | | - Arndt-Peter Schulz
- BG Hospital Hamburg, Trauma Surgery, Orthopedics and Sports Traumatology, Bergedorfer Strasse 10, 21033, Hamburg, Germany
- Medical Faculty, Universität zu Lübeck, Ratzeburger Allee 160, 23562, Lübeck, Germany
| |
Collapse
|
3
|
Migliorini F, Maffulli N, Pilone M, Velaj E, Hofmann UK, Bell A. Demographic characteristics influencing the stem subsidence in total hip arthroplasty: an imaging study. Arch Orthop Trauma Surg 2024; 144:887-894. [PMID: 37770626 PMCID: PMC10822810 DOI: 10.1007/s00402-023-05054-y] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 03/22/2023] [Accepted: 09/02/2023] [Indexed: 09/30/2023]
Abstract
INTRODUCTION The present study evaluated whether patient demographic characteristics influence the subsidence of the stem in total hip arthroplasty (THA). The following characteristics were evaluated: age, height, weight, and sex. The association between the time elapsed from the THA implantation and the amount of stem subsidence was also investigated. METHODS The records of patients who underwent THA in the period between 2016 and 2023 were accessed. All patients underwent two-staged bilateral THA using cementless DePuy collarless Corail (DePuy Synthes, Raynham, MA, USA) stems. The following parameters were measured and compared to assess stem subsidence: distance from the proximal femur at the stem bone interface and the medial apex of the regular triangle built within the trochanter minor (point A); distance from the medial apex of the regular triangle built within the trochanter minor and the distal portion of the femoral stem (point B). RESULTS Overall, 294 patients were included. 62% (182 of 294 patients) were women. 45% (134 of 296 THAs) were on the right side. The mean age was 64.9 ± 10.4 years. The mean BMI was 28.3 ± 5.1 kg/m2. The mean length of the follow-up was 14.4 ± 11.0 months. The mean subsidence in point A was 2.1 mm (P < 0.0001), and that in point B was 3.1 mm (P < 0.0001). There was evidence of a weak positive association between patient weight (P < 0.0001), age (P = 0.03), follow-up (P = 0.002) and the amount of stem subsidence. Patient height did not demonstrate any association with the amount of stem subsidence (P = 0.07). There was no difference in stem subsidence between women and men (P = 0.9). CONCLUSION Stem subsidence in THA using cementless DePuy collarless Corail implants is approximately 2.6 mm after 14.4 months. Greater patient weight, age, and longer time elapsed from THA implantation were associated with greater stem subsidence. Patient height and sex did not demonstrate any influence on the amount of stem subsidence. These results must be considered in light of the limitations of the present study.
Collapse
Affiliation(s)
- Filippo Migliorini
- Department of Orthopaedics, Trauma, and Reconstructive Surgery, University Clinic Aachen, RWTH Aachen University Medical Centre, Pauwelsstraße 30, 52064, Aachen, Germany.
- Department of Orthopaedics and Trauma Surgery, Academic Hospital of Bolzano (SABES-ASDAA), Teaching Hospital of Paracelsus Medical University (PMU), 39100 Bolzano, Italy.
| | - Nicola Maffulli
- Department of Orthopaedic and Trauma Surgery, Hospital Sant'Andrea, University of Rome La Sapienza, Rome, Italy
- School of Pharmacy and Bioengineering, Keele University School of Medicine, Thornburrow Drive, Stoke On Trent, England
- Barts and the London School of Medicine and Dentistry, Centre for Sports and Exercise Medicine, Mile End Hospital, Queen Mary University of London, 275 Bancroft Road, London, E1 4DG, England
| | - Marco Pilone
- Department of Orthopaedic and Trauma Surgery, Hospital Sant'Andrea, University of Rome La Sapienza, Rome, Italy
- Residency Program in Orthopedics and Traumatology, University of Milan, Milan, Italy
| | - Erlis Velaj
- Department of Orthopaedics, Trauma, and Reconstructive Surgery, University Clinic Aachen, RWTH Aachen University Medical Centre, Pauwelsstraße 30, 52064, Aachen, Germany
| | - Ulf Krister Hofmann
- Department of Orthopaedics, Trauma, and Reconstructive Surgery, University Clinic Aachen, RWTH Aachen University Medical Centre, Pauwelsstraße 30, 52064, Aachen, Germany
| | - Andreas Bell
- Department of Orthopedics, Eifelklinik St. Brigida, 52152, Simmerath, Germany
| |
Collapse
|
4
|
Tottas S, Ververidis A, Kougioumtzis I, Tilkeridis K, Tsigalou C, Karaglani M, Drosos G. MINIMA Short Stem Versus Standard Profemur (TL) Stem in Primary Total Hip Replacement: A Comparative Study. Cureus 2022; 14:e23771. [PMID: 35509762 PMCID: PMC9062282 DOI: 10.7759/cureus.23771] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Accepted: 04/02/2022] [Indexed: 12/28/2022] Open
Abstract
Background: The objective of our study was to compare a novel squared section, tapered design - with four conicity - short stem, the MINIMA® short stem with the cementless Profemur® TL standard femoral stem in primary total hip arthroplasty (THA) in terms of functional outcomes, radiologic evaluation and other peri-operative and post-operative data. Material and methods: This is a comparative study including 46 patients undergoing primary THA. In 23 patients, the MINIMA® short stem was used. These patients were matched with another 23 patients in whom a cementless Profemur® TL standard femoral stem was used. The levels of the pain were evaluated according to the Visual Analog Scale/Numerical Rating Scale (VAS/NRS). The functional and clinical evaluation of the patients was performed with Harris Hip Score (HHS), Charnley’s Hip score, EuroQol (EQ-5D)-(EQ-100), Patient Health Questionnaire (PHQ-9), and neuropathic pain questionnaire (DN-4). The rest of the comparison data included demographic data, the American Society of Anesthesiologists score (ASA), Charlson Index score, the pre-operative diagnosis, radiographic evaluation, the days of hospitalization, the operating time, incision length, blood loss, and blood transfusion requirements and complication rates. Results: The two cohorts had comparable results regarding all patients’ peri-operative data. The radiographic assessment revealed considerable higher levels of femoral offset and femoral subsidence for the MINIMA group, but within acceptable limits for both cohorts. The majority of the functional and other scores did not give strong prominence to one specific femoral stem. Conclusion: Our comparative study underlined the efficacy of the MINIMA® short stem, due to the fact that it revealed comparable and, in some cases, relatively better short-term outcomes compared with the TL standard femoral stem. Yet, more well-designed long-term research is required in order to further establish its effectiveness.
Collapse
Affiliation(s)
- Stylianos Tottas
- Orthopeadics, University General Hospital of Alexandroupolis/Democritus University of Thrace, Alexandroupolis, GRC
| | - Athanasios Ververidis
- Orthopeadics, University General Hospital of Alexandroupolis/Democritus University of Thrace, Alexandroupolis, GRC
| | - Ioannis Kougioumtzis
- Orthopeadics, University General Hospital of Alexandroupolis/Democritus University of Thrace, Alexandroupolis, GRC
| | - Konstantinos Tilkeridis
- Orthopeadics, University General Hospital of Alexandroupolis/Democritus University of Thrace, Alexandroupolis, GRC
| | - Christina Tsigalou
- Medical-Molecular Microbiology, University General Hospital of Alexandroupolis/Democritus University of Thrace, Alexandroupolis, GRC
| | - Makrina Karaglani
- Laboratory of Pharmacology, Medical School/Democritus University of Thrace, Alexandroupolis, GRC
| | - Georgios Drosos
- Orthopeadics, University General Hosital of Alexandroupolis/Democritus University of Thrace, Alexandroupolis, GRC
| |
Collapse
|
5
|
Subsidence of a metaphyseal-anchored press-fit stem after 4-year follow-up: an EBRA-FCA analysis. Arch Orthop Trauma Surg 2022; 142:2075-2082. [PMID: 34287700 PMCID: PMC9296414 DOI: 10.1007/s00402-021-04068-8] [Citation(s) in RCA: 2] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 09/18/2020] [Accepted: 07/10/2021] [Indexed: 11/21/2022]
Abstract
PURPOSE Uncemented stem migration analysis by EBRA-FCA (Einzel-Bild-Roentgen Analyse, Femoral Component Analyse) has been seen to be a good predictive indicator for early implant failure. In this study, we investigated the migration behavior of a cementless metaphyseal-anchored press-fit stem after 4-year follow-up. METHODS Applying a retrospective study design, we reviewed all consecutive patients who between 2012 and 2017 received a cementless Accolade II press-fit stem at our Department. We reviewed medical histories and performed radiological measurements using EBRA-FCA software. EBRA-FCA measurements and statistical investigations were performed by two independent investigators. RESULTS A total of 102 stems in 91 patients (female 60; male 31) fulfilled our inclusion criteria. Mean age at surgery was 66.2 (range 24.3-92.6) years. EBRA migration analysis showed a mean subsidence of 1.4 mm (range 0.0-12.0) at final follow-up. The angle between stem and femur axis was 0.5° (range 0.0°-2.8°) after 48 months. No correlations between gender or Dorr types and subsidence were found (p > 0.05). A body mass index > 30 kg/m2 showed a significant increase in stem subsidence within the first 6 (p = 0.0258) and 12 months (p = 0.0466) postoperative. CONCLUSIONS Migration pattern of the metaphyseal-anchored stem and a low subsidence rate at final follow-up may predict a good long-term clinical result. TRIAL REGISTRATION Number: 20181024-1875.
Collapse
|
6
|
Dammerer D, Blum P, Putzer D, Krappinger D, Pabinger C, Liebensteiner MC, Thaler M. Migration characteristics of the Corail hydroxyapatite-coated femoral stem-a retrospective clinical evaluation and migration measurement with EBRA. Arch Orthop Trauma Surg 2022; 142:517-524. [PMID: 33999259 PMCID: PMC8843908 DOI: 10.1007/s00402-021-03926-9] [Citation(s) in RCA: 9] [Impact Index Per Article: 4.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 09/18/2020] [Accepted: 04/29/2021] [Indexed: 11/27/2022]
Abstract
PURPOSE Uncemented stem migration analysis by EBRA-FCA (Einzel-Bild-Roentgen Analyse, Femoral Component Analysis) has been seen to be a good predictive indicator for early implant failure. In this study, we investigated the migration behavior of a cementless press-fit stem after two years follow-up. Stem type and postoperative gap between collar and femur were evaluated as a risk factor. METHODS Applying a retrospective study design, we reviewed all consecutive patients who between 2013 and 2017 received a cementless press-fit Corail stem (DePuy Orthopaedics Inc., Warsaw, IN, USA) at our Department. We reviewed medical histories and performed radiological measurements using EBRA-FCA software. RESULTS A total of 109 stems in 105 patients (female: 60; male: 45) fulfilled our inclusion criteria. Mean age at surgery was 67.8 (range, 21.6-90.5) years. EBRA migration analysis showed a mean subsidence of 1.8 mm (range, 0.0-12.1) at final follow-up. At 18 months mean subsidence of collared stems was significantly lower than in the collarless group [1.3 mm (range, 0.0-7.6) vs. 3.2 mm (range, 0.5-10.7), p = 0.0104]. Collared stems resting on the femoral cut presented a tendency to less subsidence than did collared stems showing a postoperative gap between collar and femur (1.3 vs. 2.0 mm) without finding statistical significance (p > 0.05). CONCLUSIONS Low subsidence and the migration pattern of the cementless press-fit stem may predict a good long-term result. Collared stems investigated in our study provide good stability and are able to prevent significant subsidence. Trial registration number and date of registration: Number: 20181024-1875; Date: 2018-10-24.
Collapse
Affiliation(s)
- Dietmar Dammerer
- Department of Orthopaedics and Traumatology, Medical University of Innsbruck, Anichstrasse 35, 6020 Innsbruck, Austria
| | - Philipp Blum
- Department of Orthopaedics and Traumatology, Medical University of Innsbruck, Anichstrasse 35, 6020 Innsbruck, Austria
| | - David Putzer
- Department of Experimental Orthopaedics, Medical University of Innsbruck, Sonnenburgstr. 16, 6020 Innsbruck, Austria
| | - Dietmar Krappinger
- Department of Orthopaedics and Traumatology, Medical University of Innsbruck, Anichstrasse 35, 6020 Innsbruck, Austria
| | - Christof Pabinger
- Medical University of Innsbruck, Christoph-Probst-Platz 52, 6020 Innsbruck, Austria
| | - Michael C. Liebensteiner
- Department of Orthopaedics and Traumatology, Medical University of Innsbruck, Anichstrasse 35, 6020 Innsbruck, Austria
| | - Martin Thaler
- Department of Orthopaedics and Traumatology, Medical University of Innsbruck, Anichstrasse 35, 6020 Innsbruck, Austria
| |
Collapse
|
7
|
Afghanyar Y, Klug A, Rehbein P, Dargel J, Drees P, Kutzner KP. One-stage bilateral versus unilateral short-stem total hip arthroplasty: A matched-pair analysis of 216 hips. J Orthop 2021; 27:130-136. [PMID: 34616117 PMCID: PMC8476895 DOI: 10.1016/j.jor.2021.09.008] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 07/24/2021] [Accepted: 09/19/2021] [Indexed: 12/01/2022] Open
Abstract
Background One-stage, bilateral, short-stem total hip arthroplasty (1B-ssTHA) represents an alternative to staged, unilateral, short-stem total hip arthroplasty (U-ssTHA); however, the safety and reliability of 1B-ssTHA remain unknown. The objective of the present study was to compare the functional outcomes, complications, and mortality rates between 1B-ssTHA and U-ssTHA at mid-term. Methods A retrospective, matched-pair study was performed, including 216 short stems implanted in 162 patients. Among the study population, 54 patients were treated with 1B-ssTHA. Patients were matched by gender, age, body mass index (BMI), and American Society of Anesthesiologists (ASA) classification. A total of 46 full matches could be accomplished. The mean follow-up time for the 1B-ssTHA group was 61.7 months (standard deviation [SD] 6.2 months), compared with was 63.4 months (SD 8.0 months) for the U-ssTHA group. Mortality, complication, and revision rates were documented. For clinical examinations, the visual analogue scale (VAS) was used to evaluate satisfaction, rest pain, and load pain, and the Harris Hip Score (HHS) was determined. Results No surgery-related deaths were observed. At mid-term, none of the 1B-ssTHA patients required stem revision. The rate of complications for both groups was low. The mean drop in haemoglobin measured in the 1B-ssTHA group was 4.42 mg/dl, compared with 3.18 mg/dl in the U-ssTHA group. The mean HHS in the 1B-ssTHA group was 98.3 points (SD 2.80), whereas, in the U-ssTHA group, the mean HHS was 97.9 points (SD 3.44) (p = 0.478). Satisfaction rates were significantly higher in the 1B-ssTHA group (p = 0.04) than in the U-ssTHA group, whereas no significant differences were found for pain at rest and pain at load (p = 0.56 and p = 0.26, respectively). Conclusion Our findings indicate that 1B-ssTHA is an effective and beneficial procedure for a select population. Mortality, complications, implant survival, and clinical outcomes were comparable to those for a matched group with unilateral osteoarthritis treated with U-ssTHA. However, an increase in blood loss must be acknowledged for the 1B-ssTHA procedure.
Collapse
Affiliation(s)
- Yama Afghanyar
- Department of Orthopaedics and Traumatology, St. Josefs Hospital Wiesbaden, Beethovenstr. 20, 65189, Wiesbaden, Germany
| | - Alexander Klug
- Department of Orthopaedics and Traumatology, Berufsgenossenschaftliche Unfallklinik Frankfurt am Main, Frankfurt am Main, Germany
| | - Philipp Rehbein
- Department of Orthopaedics and Traumatology, St. Josefs Hospital Wiesbaden, Beethovenstr. 20, 65189, Wiesbaden, Germany
| | - Jens Dargel
- Department of Orthopaedics and Traumatology, St. Josefs Hospital Wiesbaden, Beethovenstr. 20, 65189, Wiesbaden, Germany
| | - Philipp Drees
- Department of Orthopaedics and Traumatology, University Medical Centre of the Johannes Gutenberg-University of Mainz, Langenbeckstraße 1, 55131, Mainz, Germany
| | - Karl Philipp Kutzner
- Department of Orthopaedics and Traumatology, St. Josefs Hospital Wiesbaden, Beethovenstr. 20, 65189, Wiesbaden, Germany.,Department of Orthopaedics and Traumatology, University Medical Centre of the Johannes Gutenberg-University of Mainz, Langenbeckstraße 1, 55131, Mainz, Germany
| |
Collapse
|
8
|
Kutzner KP. Calcar-guided short-stem total hip arthroplasty: Will it be the future standard? Review and perspectives. World J Orthop 2021; 12:534-547. [PMID: 34485100 PMCID: PMC8384612 DOI: 10.5312/wjo.v12.i8.534] [Citation(s) in RCA: 14] [Impact Index Per Article: 4.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 02/14/2021] [Revised: 05/10/2021] [Accepted: 07/20/2021] [Indexed: 02/06/2023] Open
Abstract
Short stems in total hip arthroplasty (THA) are becoming increasingly popular. In Germany, already 10.4% of all primary THAs are performed using a cementless short stem. The concept of modern, calcar-guided, short stems aims for an individualized reconstruction of the hip anatomy by following the calcar of the femoral neck, a bone- and soft-tissue-sparing implantation technique, and physiological loading. The stem design uses either metaphyseal fixation alone or additional diaphyseal anchoring, depending on the stem alignment and indication. These individualized anchorage types increase the potential indications for the safe use of a short stem. The design features may account for potential advantages of current short stem implants compared with earlier short-stem designs, particularly in cases of reduced bone quality or osteonecrosis of the femoral head and femoral neck fractures. The implantation technique, however, requires distinct knowledge regarding the characteristics of varus and valgus positioning, with the potential for clinical consequences. A learning curve for surgeons new to this technique must be taken into account. Cortical contact with the distal lateral cortex appears to be crucial to provide sufficient primary stability, and the use of intraoperative imaging to identify “undersizing” is highly recommended. Current results of several national registries indicate that calcar-guided short stems are among the most successful implants in terms of mid-term survivorship. However, long-term data remain scarce. This review introduces the characteristics of calcar-guided short-stem THA and summarizes the current evidence.
Collapse
Affiliation(s)
- Karl Philipp Kutzner
- Department of Orthopaedic Surgery, St Josefs Hospital Wiesbaden, Germany, Wiesbaden 65189, Germany
- Department of Hip Surgery, Gelenkzentrum Rhein-Main, Wiesbaden 65183, Germany
- Center of Orthopedics and Traumatology, Johannes Gutenberg-University of Mainz, Mainz 55131, Germany
| |
Collapse
|
9
|
Hasler J, Flury A, Dimitriou D, Holweg I, Helmy N, Finsterwald M. Mid-term subsidence and periprosthetic radiolucency of the AMIStem: a 5-year EBRA-FCA analysis. J Orthop Surg Res 2021; 16:19. [PMID: 33413463 PMCID: PMC7792117 DOI: 10.1186/s13018-020-02104-8] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 10/04/2020] [Accepted: 11/19/2020] [Indexed: 01/22/2023] Open
Abstract
Background There has been an evolution in cementless total hip arthroplasty (THA) with newer short stem designs aimed to preserve metaphyseal bone stock and facilitate implantation through minimally invasive approaches. While early subsidence has been correlated to aseptic loosening in conventional stems, there is a paucity of data regarding short stems. The current study aims to report on stem subsidence and mid-term clinical outcomes of a cementless, metaphyseal-anchored short femoral stem, specifically designed for the direct anterior approach (DAA). Methods Ninety-four consecutive patients (100 hips) with a minimum follow-up of 5 years following cementless THA were included in this single-center retrospective study. Subsidence was evaluated using the “Ein-Bild-Roentgen-Analyse” (EBRA). Periprosthetic radiolucency allocated to the zones of Charnley and Gruen was assessed. Additionally, demographic and implant-related factors potentially associated with increased subsidence and clinical outcomes were evaluated. Results At the last follow-up, the average stem subsidence was 1.98 ± 1.20 mm, with 48% of the implants demonstrating subsidence of > 2 mm. Periprosthetic radiolucency of > 2 mm was found in 26% of the implants in zone 1 and in 9% in zone 7, respectively. Neither the amount of subsidence nor proximal periprosthetic radiolucency was associated with aseptic loosening or worse clinical outcomes. Conclusions Comparable to other proximally fixed short stem designs, the highest subsidence was observed within the first 3 months following implantation. No demographic or implant-related factors were found to have a statistically significant influence on stem subsidence. Periprosthetic radiolucency and subsidence of the AMISstem is not correlated with worse clinical outcomes at 5-year follow-up.
Collapse
Affiliation(s)
- Julian Hasler
- Departement of Orthopaedics and Traumatology, Bürgerspital Solothurn, Solothurn, Switzerland.
| | - Andreas Flury
- Departement of Orthopaedics and Traumatology, Bürgerspital Solothurn, Solothurn, Switzerland
| | - Dimitris Dimitriou
- Departement of Orthopaedics and Traumatology, Bürgerspital Solothurn, Solothurn, Switzerland
| | - Iris Holweg
- Departement of Orthopaedics and Traumatology, Bürgerspital Solothurn, Solothurn, Switzerland
| | - Naeder Helmy
- Departement of Orthopaedics and Traumatology, Bürgerspital Solothurn, Solothurn, Switzerland
| | - Michael Finsterwald
- Departement of Orthopaedics and Traumatology, Bürgerspital Solothurn, Solothurn, Switzerland
| |
Collapse
|
10
|
Two-year radiologic assessment of the Pinnacle cup-a migration analysis with EBRA. Arch Orthop Trauma Surg 2021; 141:149-154. [PMID: 33128095 PMCID: PMC7815589 DOI: 10.1007/s00402-020-03648-4] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 05/18/2020] [Accepted: 10/15/2020] [Indexed: 11/27/2022]
Abstract
INTRODUCTION The most common cause of failure in total hip arthroplasty (THA) is aseptic loosening. Uncemented cup migration analysis by EBRA (Einzel-Bild-Roentgen-Analyse) has shown to be a good predictive indicator for early implant failure if the cup migrates more than 1 milimeter (mm) within the first 2 years after surgery. In this study, we investigated the migration behaviour of an uncemented press-fit cup after 2 years follow-up. MATERIALS AND METHODS Applying a retrospective study design, we reviewed all consecutive patients who received an uncemented press-fit cup at our Department between 2013 and 2018. A total of 484 patients were identified. We reviewed medical histories and performed radiological measurements using EBRA-Cup software. EBRA measurements and statistical investigations were performed by two independent investigators. RESULTS A total of 165 cups in 159 patients (female: 90; male: 69) met our inclusion criteria. Mean age at surgery was 66.7 (range 18.4-90.5) years. EBRA migration analysis showed a mean total migration of 0.7 mm (range 0.0-6.3) over our follow-up period of 2 years. Of the investigated cups, 53.2% showed less than 1 mm migration in the investigated follow-up period. CONCLUSION In conclusion, the Pinnacle cup used in our study provides low mean migration at final follow-up. Based on the assumption of secondary stabilization, good long-term outcome of the Pinnacle cup can be expected. TRIAL REGISTRATION NUMBER AND DATE OF REGISTRATION Number: 20181024-1875; Date: 2018-09-20.
Collapse
|
11
|
Stoffel K, Horn T, Zagra L, Mueller M, Perka C, Eckardt H. Periprosthetic fractures of the proximal femur: beyond the Vancouver classification. EFORT Open Rev 2020; 5:449-456. [PMID: 32818072 PMCID: PMC7407870 DOI: 10.1302/2058-5241.5.190086] [Citation(s) in RCA: 10] [Impact Index Per Article: 2.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 11/06/2022] Open
Abstract
The majority of periprosthetic femoral fractures are treated surgically. Surgical treatment may be revision only, revision in combination with open reduction and internal fixation (ORIF), or ORIF only. The treatment decision is dependent on whether the stem is loose or not, but loose stems are not always identified, resulting in unsatisfactory treatments. This article presents an algorithmic approach to identifying loose stems around proximal femoral periprosthetic fractures, taking patient history, stem design, and plain radiographs into consideration. This approach may help identifying loose stems and increase the probability of effective treatments.
Cite this article: EFORT Open Rev 2020;5:449-456. DOI: 10.1302/2058-5241.5.190086
Collapse
Affiliation(s)
- Karl Stoffel
- Department of Orthopaedics and Traumatology, University Hospital Basel, Basel, Switzerland
| | - Tamara Horn
- Clinic of Orthopaedic Surgery, Kantonsspital Baselland, Liestal, Switzerland
| | - Luigi Zagra
- Hip Department, IRCCS Galeazzi Orthopaedic Institute, Milano, Italy
| | - Michael Mueller
- Orthopaedic Department, Charité - Universitätsmedizin Berlin, Berlin, Germany
| | - Carsten Perka
- Orthopaedic Department, Charité - Universitätsmedizin Berlin, Berlin, Germany
| | - Henrik Eckardt
- Department of Orthopaedics and Traumatology, University Hospital Basel, Basel, Switzerland
| |
Collapse
|
12
|
Kim SS, Kim HJ, Kim KW, Jung YH, Heo SY. Comparative Analysis between Short Stem and Conventional Femoral Stem in Patients with Osteonecrosis of Femoral Head: Metha Stem and Excia Stem. Orthop Surg 2020; 12:819-826. [PMID: 32469158 PMCID: PMC7307223 DOI: 10.1111/os.12684] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 01/20/2020] [Revised: 03/09/2020] [Accepted: 03/26/2020] [Indexed: 11/12/2022] Open
Abstract
Objective To compare the intraoperative, radiological, and clinical short‐term outcomes of cementless total hip arthroplasties (THA) using a short stem (SS) and a conventional femoral stem (CS) in a randomized prospective control study. Methods From June 2011 to October 2017, patients who underwent cementless THA for idiopathic osteonecrosis of the femoral head were recruited. Patients had a minimum 2 years of follow‐up after the operation. The patients were divided into two groups: those who underwent THA using an SS and those who underwent THA using a CS. SS were used in 34 patients (41 hips) and CS were used in 41 patients (45 hips). In both groups, the same cup was used in all cases, and the mean follow‐up periods were 63 (26–101) months in the SS and 64 (26–101) months in the CS groups. Intraoperative, clinical, and radiological evaluations were performed for the two groups. Results There was no difference in the demographics of the two groups. There was one patient with a proximal femoral crack in the SS group and one with a distal femoral crack in the CS group. Clinically, the mean Harris hip score was improved in both groups at 2‐year follow‐up. Radiographically endosteal osseointegrations were found in 40 of 41 cases in the SS group and in 44 of 45 cases in the CS group. There was one case of dislocation in each group. In the SS group, the acetabular cup was changed and repositioned 7 months after the initial operation. Stem loosening, infection, ceramic breakage, and varus/valgus change were not observed. There was a statistically significant lower stress shielding effect in the SS group. There were no differences in vertical/parallel offset and leg length discrepancy. Conclusion The intraoperative, radiological, and clinical evaluations in both groups showed good outcomes and there was no statistically significant difference between the two groups.
Collapse
Affiliation(s)
- Sung Soo Kim
- Department of Orthopaedic Surgery, College of Medicine, Dong-A University, Busan,, South Korea
| | - Hyeon Jun Kim
- Department of Orthopaedic Surgery, College of Medicine, Dong-A University, Busan,, South Korea
| | - Ki Woong Kim
- Department of Orthopaedic Surgery, Dong Kang Hospital, Ulsan, South Korea
| | - Young Hun Jung
- Department of Orthopaedic Surgery, College of Medicine, Dong-A University, Busan,, South Korea
| | - Si Young Heo
- Department of Orthopaedic Surgery, College of Medicine, Dong-A University, Busan,, South Korea
| |
Collapse
|
13
|
Gombár C, Janositz G, Friebert G, Sisák K. The DePuy Proxima™ short stem for total hip arthroplasty - Excellent outcome at a minimum of 7 years. J Orthop Surg (Hong Kong) 2020; 27:2309499019838668. [PMID: 30939986 DOI: 10.1177/2309499019838668] [Citation(s) in RCA: 10] [Impact Index Per Article: 2.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 11/15/2022] Open
Abstract
PURPOSE Metaphyseal, proximally anchored uncemented stems for total hip arthroplasty provide bone preservation and decrease the incidence of proximal stress shielding and thigh pain. Our study investigated the clinical and radiological outcome of the DePuy Proxima™ short stem at a minimum of 7 years. METHODS Eighty-one consecutive patients (86 procedures) under the age of 70 undergoing primary total hip replacement at two arthroplasty centres were enrolled. Follow-up was clinical (Harris Hip Score (HHS), thigh pain and satisfaction) and radiological (subsidence, malalignment and loosening) at 6 months and yearly thereafter. RESULTS Average age was 50 (range 32-65) with 79% (68 of 86) being male. Preoperative diagnosis included primary osteoarthritis (OA) 36%, avascular necrosis of femoral head 51%, dysplasia 9% and post-traumatic OA 4%. HHS improved 51 points at latest follow-up (from 40 to 91). We had 3.5% (3 of 86) periprosthetic fractures, one requiring revision. We had one dislocation, no infections and no thigh pain. Malalignment rate (≥5° off neutral) was 12% (10 of 86), not affecting clinical results. CONCLUSION Overall stem survival was over 97% at 7 years. The DePuy Proxima provides excellent clinical results at a minimum of 7 years post-operatively.
Collapse
Affiliation(s)
- Csaba Gombár
- 1 Department of Orthopaedics, University of Szeged, Szeged, Hungary
| | - Gábor Janositz
- 2 Department of Orthopaedics, Bacs-Kiskun District General Hospital, Kecskemét, Hungary
| | - Gábor Friebert
- 1 Department of Orthopaedics, University of Szeged, Szeged, Hungary
| | - Krisztián Sisák
- 1 Department of Orthopaedics, University of Szeged, Szeged, Hungary
| |
Collapse
|
14
|
Clinical evaluation of a novel press-fit acetabular cup using "Ein-Bild-Roentgen-Analysis" (EBRA): A positive short-term prognosis. J Orthop 2020; 22:33-37. [PMID: 32280166 DOI: 10.1016/j.jor.2020.03.059] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 03/25/2020] [Accepted: 03/28/2020] [Indexed: 11/23/2022] Open
Abstract
Introduction Demographic change and demand for high quality of life lead to increasing implantation numbers. Aim of this study was to compare the Plasmafit® cup to Allofit® and Plasmacup®. Methods The study included 174 patients who had received 33 Plasmacup®, 68 Allofit® and 73 Plasmafit® cup implants. These were reviewed postoperatively, after 6 months control and after 12 months. Results No significant progressive migration could be discovered in any of the cup systems. At each follow-up the cups showed nearly constant values. Conclusions All examined acetabular cups showed excellent migration behavior within the first 12 postoperative months.
Collapse
|
15
|
Primary stability of calcar-guided short-stem total hip arthroplasty in the treatment of osteonecrosis of the femoral head: migration analysis using EBRA-FCA. Arch Orthop Trauma Surg 2020; 140:2091-2100. [PMID: 33011847 PMCID: PMC7674354 DOI: 10.1007/s00402-020-03610-4] [Citation(s) in RCA: 13] [Impact Index Per Article: 3.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 05/07/2020] [Accepted: 09/25/2020] [Indexed: 12/11/2022]
Abstract
INTRODUCTION Osteonecrosis of the femoral head (ONFH) is a disabling condition that often results in secondary arthritis necessitating total hip arthroplasty (THA). Short-stem THA has constantly gained popularity. It remains controversial, whether ONFH represents a risk factor for failure after the implantation of short stems with pronounced metaphyseal anchorage. The potential spread of the osteonecrotic area and bone marrow edema into the metaphyseal bone might result in compromised stability. Early implant migration is considered predictive of subsequent aseptic loosening. The purpose of this study was a migration analysis of a modern, calcar-guided short-stem implant in patients with ONFH in a mid-term follow-up. MATERIALS AND METHODS This retrospective analysis investigated the migration pattern of 45 calcar-guided short stems in patients with ONFH, using Einzel-Bild-Roentgen-Analyse Femoral-Component-Analysis (EBRA-FCA). Influencing factors such as ARCO categories, age, gender, body weight and BMI were analyzed. Complications and adverse events were documented. RESULTS At mid-term [48.1 months (SD 20.7 months)], mean axial migration was 1.56 mm (SD 1.77 mm). Mean migration rate stabilized after 2 years. No influence of ARCO categories, age and BMI was found. A tendency of increased axial migration was observed in male patients and in overweight patients. No revision surgeries had to be performed during follow-up. CONCLUSION The results indicate a migration pattern comparable to that of primary osteoarthritis patients with slight initial migration under full load followed by subsequent stabilization in the metaphyseal femur. The 100% survival rate at mid-term supports the usage of this short-stem design in patients with ONFH.
Collapse
|
16
|
Kutzner KP, Donner S, Loweg L, Rehbein P, Dargel J, Drees P, Pfeil J. Mid-term results of a new-generation calcar-guided short stem in THA: clinical and radiological 5-year follow-up of 216 cases. J Orthop Traumatol 2019; 20:31. [PMID: 31673809 PMCID: PMC6823459 DOI: 10.1186/s10195-019-0537-z] [Citation(s) in RCA: 14] [Impact Index Per Article: 2.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 06/17/2019] [Accepted: 08/23/2019] [Indexed: 12/12/2022] Open
Abstract
BACKGROUND In recent years, a variety of short stems have been introduced. To date, mid- and long-term results of calcar-guided short-stem designs have been rarely available. MATERIALS AND METHODS Two hundred and sixteen calcar-guided short stems were included in combination with a cementless cup in a prospective study. Patients were allowed full weight-bearing on the first day postoperatively. Harris hip score (HHS) as well as pain and satisfaction on visual analogue scale (VAS) were assessed during a median follow-up of 61.7 months. Standardised radiographs were analysed at predefined time points regarding radiological alterations such as bone resorption and remodelling, radiolucency, osteolysis and cortical hypertrophy using modified Gruen zones. RESULTS At mid-term follow-up, no revision surgery of the stem had to be performed in the whole collective. At 5 years, HHS was 97.8 (SD 4.7), satisfaction on VAS was 9.7 (SD 0.7), rest pain on VAS was 0.1 (SD 0.5), and load pain on VAS was 0.6 (SD 1.2). Compared to the 2-year results, femoral bone resorption increased significantly at the 5-year follow-up (3.9% versus 42.3%). Rate of femoral cortical hypertrophy remained stable, occurring in a total of 9 hips (4.5%). At the 5-year follow-up, 2 stems (1.0%) showed non-progressive radiolucent lines with a maximum width of 2 mm. Signs of osteolysis were not observed. Compared to the 2-year follow-up, no further subsidence was observed. CONCLUSIONS The rate of stem revision (0%) at the mid-term follow-up was remarkable and indicates the principle of using a calcar-guided short stem as being a safe procedure. However, signs of bone-remodelling, indicating some amount of stress-shielding, must be acknowledged at 5 years depending on stem alignment and type of anchorage. LEVEL OF EVIDENCE IV, Prospective observational study Trial registration German Clinical Trials Register, DRKS00012634, 07/07/2017 (retrospectively registered).
Collapse
Affiliation(s)
- Karl Philipp Kutzner
- Department of Orthopaedic Surgery and Traumatology, St. Josefs Hospital Wiesbaden, Beethovenstr. 20, 65189, Wiesbaden, Germany. .,Department for Orthopaedics and Traumatology, University Medical Centre of the Johannes Gutenberg University Mainz, Mainz, Germany.
| | - Stefanie Donner
- Department of Orthopaedic Surgery and Traumatology, St. Josefs Hospital Wiesbaden, Beethovenstr. 20, 65189, Wiesbaden, Germany
| | - Lennard Loweg
- Department of Orthopaedic Surgery and Traumatology, St. Josefs Hospital Wiesbaden, Beethovenstr. 20, 65189, Wiesbaden, Germany
| | - Philipp Rehbein
- Department of Orthopaedic Surgery and Traumatology, St. Josefs Hospital Wiesbaden, Beethovenstr. 20, 65189, Wiesbaden, Germany
| | - Jens Dargel
- Department of Orthopaedic Surgery and Traumatology, St. Josefs Hospital Wiesbaden, Beethovenstr. 20, 65189, Wiesbaden, Germany
| | - Philipp Drees
- Department for Orthopaedics and Traumatology, University Medical Centre of the Johannes Gutenberg University Mainz, Mainz, Germany
| | - Joachim Pfeil
- Department of Orthopaedic Surgery and Traumatology, St. Josefs Hospital Wiesbaden, Beethovenstr. 20, 65189, Wiesbaden, Germany
| |
Collapse
|
17
|
Kang JS, Na Y, Ko BS, Jeon YS. Clinical outcomes and survival rate of cementless modular distal fixation femoral stem for revision hip arthroplasty: A minimum 6-year follow-up. J Orthop Surg (Hong Kong) 2019; 26:2309499018812241. [PMID: 30449250 DOI: 10.1177/2309499018812241] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 11/16/2022] Open
Abstract
PURPOSE Revision hip arthroplasty is a very challenging procedure. Use of a modular distal fixation stem is one of the available options for revision arthroplasty in patients with proximal femoral bone deficiency. The purpose of this study was to evaluate mid- to long-term outcomes of cementless modular distal fixation femoral stem implantation in revision hip surgery. METHODS Clinical and radiological findings, complications, and stem survival rate were analyzed for 46 patients (48 hips) who underwent revision hip arthroplasty using a cementless modular distal fixation femoral stem. The mean patient age was 58.8 years (range 31-82 years) and the mean follow-up period was 95 months (72-122 months). The preoperative diagnoses were aseptic loosening (36 hips), infection (4 hips), ceramic fracture (4 hips), and femoral periprosthetic fracture (4 hips). RESULTS The mean Harris hip score improved from 56.6 preoperatively to 88.2 postoperatively at the last follow-up. All hips showed stable osteointegration and firm fixation. Complications involved four hips (8.3%); there was one case each of periprosthetic fracture, delayed union of osteotomy site, femoral perforation, and infection. One stem re-revision was performed for deep infection of the femoral side. The Kaplan-Meier survival rate was 97.6% at the final follow-up. CONCLUSION Revision hip arthroplasty using a cementless modular distal fixation femoral stem showed satisfactory initial firm fixation and mid- to long-term survival rate. Complications can be minimized by careful surgical planning and meticulous procedure.
Collapse
Affiliation(s)
- Joon Soon Kang
- Department of Orthopedic Surgery, College of Medicine, Inha University Hospital, Incheon, Korea
| | - Yeop Na
- Department of Orthopedic Surgery, College of Medicine, Inha University Hospital, Incheon, Korea
| | - Bong Seong Ko
- Department of Orthopedic Surgery, College of Medicine, Inha University Hospital, Incheon, Korea
| | - Yoon Sang Jeon
- Department of Orthopedic Surgery, College of Medicine, Inha University Hospital, Incheon, Korea
| |
Collapse
|
18
|
Born P, Manzoni I, Ilchmann T, Clauss M. Is cemented revision total hip arthroplasty a reasonable treatment option in an elderly population? Orthop Rev (Pavia) 2019; 11:8263. [PMID: 31616553 PMCID: PMC6790558 DOI: 10.4081/or.2019.8263] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 07/31/2019] [Accepted: 08/25/2019] [Indexed: 12/03/2022] Open
Abstract
Revision THA is increasingly performed especially in the elderly population. The surgeon’s challenge is to provide a solution that supports immediate full weight-bearing, despite poor bone quality. Shape-closed revision stems facilitate that by combining cement fixation with additional press-fit anchoring. The design tolerates varying cement mantle thickness and inconsistent cancellous bone lining of the femoral canal. Following that philosophy, we present our mid-term results using a long version of a cemented Charnley- Kerboull type stem. From 2010 to 2017, 38 long Charnley-Kerboull revision stems (Centris®, Mathys European Orthopaedics, Bettlach, Switzerland) were implanted and followed prospectively. Surgery was performed via a Hardinge approach in supine position with a third generation cementing technique. Patients were mobilized using full-weight bearing as early as possible. Survival was determined for stem revision for aseptic loosening and stem and/or cup revision for any reason. 20 stems had a minimum follow-up (f/u) of 2 years and were included for further radiological analysis. Detailed subsidence analysis as an early predictor for later aseptic loosening was performed using EBRA-FCA software. Further, the presence of osteolysis and cement debonding was evaluated. Mean follow- up was 4 years. No patient was lost to f/u.18 died of causes unrelated to THA. Stem survival was 100%. Survival for any re-operation was 82.2% (two early infections, one soft-tissue debridement, one cup exchange for recurrent dislocations). None of the cases revised for septic loosening showed signs of persistent infection at final f/u. EBRA-FCA revealed two oligosymptomatic cases of subsidence of 5mm and 6mm over a course of 2 and 12 months, respectively, with stable implants thereafter. Neither required revision. There was no development of osteolysis or debonding. The stem provides a reliable early fullweight bearing solution for revision THA with excellent mid-term survival in an elderly population. Even in two cases where subsidence was present, mobility was not impaired and re-revision could be avoided.
Collapse
Affiliation(s)
- Philipp Born
- Clinic for Orthopedic and Trauma Surgery, Kantonsspital Baselland, Liestal
| | - Isabella Manzoni
- Clinic for Orthopedic and Trauma Surgery, Kantonsspital Baselland, Liestal
| | - Thomas Ilchmann
- Clinic for Orthopedic and Trauma Surgery, Kantonsspital Baselland, Liestal.,Hirslanden Klinik Birshof, Münchenstein
| | - Martin Clauss
- Clinic for Orthopedic and Trauma Surgery, Kantonsspital Baselland, Liestal.,Department of Orthopedics and Traumatology, University Hospital Basel, University of Basel, Switzerland
| |
Collapse
|
19
|
Jacquel A, Le Viguelloux A, Valluy J, Saffarini M, Bonin N. A shortened uncemented stem offers comparable positioning and increased metaphyseal fill compared to a standard uncemented stem. J Exp Orthop 2019; 6:28. [PMID: 31240502 PMCID: PMC6593034 DOI: 10.1186/s40634-019-0197-1] [Citation(s) in RCA: 7] [Impact Index Per Article: 1.4] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 03/21/2019] [Accepted: 06/14/2019] [Indexed: 01/19/2023] Open
Abstract
BACKGROUND Shortened stems are increasingly used in uncemented total hip arthroplasty (THA) as they represent a compromise between the metaphyseal anchorage of short stems and the facilitated axial alignment of standard stems. The purpose of this study was to compare the metaphyseal canal-fill ratio (CFR) and axial alignment of a shortened double-tapered stem with those of a standard stem. The hypothesis was that the shortened stem would achieve greater metaphyseal fill and comparable axial alignment. METHODS The authors reviewed routine follow-up anteroposterior radiographs taken 2 months after THA to evaluate metaphyseal fill and axial alignment of a shortened stem (n = 96) and a standard stem (n = 101). The CFR was calculated at the level of the tip and superior margin of the lesser trochanter. Stem alignment was defined as the angle between the stem axis and the proximal anatomic femoral axis. Stems were classified as being in varus or valgus alignment if they deviated by more than 3° from the anatomic axis of the femur. RESULTS Hips implanted with shortened and standard stems had comparable demographics and axial alignment (1.1° ± 1.7° vs 0.8° ± 1.2°; p = 0.331). However, varus alignment was observed in 5% of shortened stems compared to only 1% of standard stems, though this difference was not significant (p = 0.111). The femoral CFR was greater using shortened stems than using standard stems, both at the level of the tip of the lesser trochanter (0.91 ± 0.05 vs 0.85 ± 0.08; p < 0.001) and at its superior margin (0.76 ± 0.06 vs 0.72 ± 0.07; p < 0.001). CONCLUSIONS Compared to the standard stem, the shortened stem had increased metaphyseal filling and equivalent alignment. These findings suggest that shortened stems could provide adequate metaphyseal fixation and correct alignment. Further studies remain necessary to evaluate how shortened stems perform in terms of osseointegration, clinical outcomes and survival.
Collapse
Affiliation(s)
- Alexandre Jacquel
- Ramsay Générale de Santé, Clinique de la Sauvegarde, Lyon-Ortho-Clinic, 8 Avenue Ben Gourion, 69009, Lyon, France
| | - Augustin Le Viguelloux
- Centre Hospitalier William Morey, 4 Rue Capitaine Drillien, 71100, Chalon Sur Saône, France
| | - Jeremy Valluy
- ReSurg SA, Rue Saint Jean 22, 1260, Nyon, Switzerland
| | - Mo Saffarini
- ReSurg SA, Rue Saint Jean 22, 1260, Nyon, Switzerland.
| | - Nicolas Bonin
- Ramsay Générale de Santé, Clinique de la Sauvegarde, Lyon-Ortho-Clinic, 8 Avenue Ben Gourion, 69009, Lyon, France
| |
Collapse
|
20
|
Madörin K, Siepen W, Manzoni I, Stoffel KK, Ilchmann T, Clauss M. Five-year prospective subsidence analysis of 100 cemented polished straight stems: A concise clinical and radiological follow-up observation. Orthop Rev (Pavia) 2019; 11:7984. [PMID: 31210913 PMCID: PMC6551455 DOI: 10.4081/or.2019.7984] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 01/06/2019] [Accepted: 05/02/2019] [Indexed: 12/31/2022] Open
Abstract
Early subsidence (>1.5mm) has been shown to be an indicator for later aseptic loosening of cemented hip stems. For the cemented twinSys® stem we published excellent short-term results at 2 years. Midterm data for this stem are available from national registers (NZL, NL), however in all of these sources, clinical and radiological results are missing. Aim of our study was to analyse mid-term survival and radiological changes around the cemented twinSys® stem with special emphasis on subsidence using EBRA-FCA. We conducted a prospective clinical and radiological 5- year follow-up study of 100 consecutive hybrid total hip arthroplasties (THA) using a polished, cemented collarless straight stem (twinSys®, Mathys AG® Bettlach, Switzerland) with a cementless monobloc pressfit cup (RM pressfit®, Mathys AG® Bettlach, Switzerland). Median age at surgery was 79 (69 to 93) years. No patient was lost to follow-up. Survival rates were calculated using the Kaplan-Meier method. Clinical (Harris Hip Score [HHS]) and radiological (cementing quality, alignment, osteolysis, debonding and cortical atrophy) outcomes and an in-depth subsidence analysis using EBRA-FCA were performed. 22 patients died in the course of follow-up unrelated to surgery, 21 stems had an incomplete radiological follow-up. 2 stems were revised, both due to an infection. The survival rate for the stem at 5 years was 98.0% (95% CI 95.3-100%). The survival rate of the stem for revision due to aseptic loosening at 5 years was 100%. The HHS improved from 53 (14-86) points preoperatively to 90 (49-100) points 5 years after surgery. Osteolysis was found in 2 stems without clinical symptoms. In 49 out of 55 patients with a complete radiological follow- up, the EBRA-FCA analysis was possible and showed an average subsidence of 0.66 (95% CI 0.46 to 0.86) mm 5 years after surgery. 10 patients showed a subsidence >1 mm, 5 of which bigger than 1.5 mm. Subsidence was independent from radiological changes and cementing quality. The cemented twinSys® stem showed excellent clinical and radiological mid-term results at five years' follow-up and seems to be a reliable implant.
Collapse
Affiliation(s)
- Kevin Madörin
- Department of Orthopedics and Trauma Surgery, Kantonsspital Baselland
| | - Wolf Siepen
- Department of Orthopedics and Trauma Surgery, Kantonsspital Baselland
| | - Isabella Manzoni
- Department of Orthopedics and Trauma Surgery, Kantonsspital Baselland
| | | | | | - Martin Clauss
- Department of Orthopedics and Trauma Surgery, Kantonsspital Baselland
| |
Collapse
|
21
|
Lee YK, Kim TY, Ha YC, Koo KH. To withhold or to implement bisphosphonate after cementless hip arthroplasty: a dilemma in elderly hip fracture patients. J Orthop Surg Res 2019; 14:66. [PMID: 30808386 PMCID: PMC6390618 DOI: 10.1186/s13018-019-1104-2] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 04/12/2018] [Accepted: 02/18/2019] [Indexed: 01/23/2023] Open
Abstract
Background Prior studies reported ambivalent effects of bisphosphonates on the fixation of cementless stem in hip arthroplasty patients. To set up the postoperative guide of bisphosphonate use after cementless hip arthroplasty, we investigated whether zoledronate has beneficial or negative effects in the stem migration and walking ability after cementless hemi-arthroplasty in elderly patients, who were operated due to femoral neck fracture. Methods We compared 59 patients (zoledronate group), who received zoledronate after cementless hemi-arthroplasty, and 66 patients (control group), who did not receive that agent. We evaluated stem subsidence, cortical porosis around the stem, and walking ability with the use of Koval’s categories at 2-year follow-up. Results No patient had more than 2 mm of stem subsidence in both groups. One patient in the control group had cortical porosis around the stem, but none in the zoledronate group. There were no significant differences in the postoperative Koval scores (p = 0.769) and in the proportion of walking recovery to pre-fracture status (p = 0.695) between the two groups. Conclusion We did not find neither beneficial nor negative effect of this agent in terms of stem fixation and walking ability. Zoledronate can be used after cementless hemi-arthroplasty to manage the osteoporosis in elderly patients.
Collapse
Affiliation(s)
- Young-Kyun Lee
- Department of Orthopaedic Surgery, Seoul National University Bundang Hospital, 166 Gumi-ro, Bundang-gu, Seongnam, 13620, South Korea
| | - Tae-Young Kim
- Konkuk University Medical Center, Department of Orthopaedic Surgery, School of Medicine, Konkuk University, 120-1, Neungdong-ro, Gwangjin-gu, Seoul, 05030, South Korea.
| | - Yong-Chan Ha
- Department of Orthopaedic Surgery, College of Medicine, Chung-Ang University, 224-1 Heukseok-dong, Dongjak-gu, Seoul, 06973, South Korea
| | - Kyung-Hoi Koo
- Department of Orthopaedic Surgery, Seoul National University Bundang Hospital, 166 Gumi-ro, Bundang-gu, Seongnam, 13620, South Korea
| |
Collapse
|
22
|
Tian S, Goswami K, Manrique J, Blevins K, Azboy I, Hozack WJ. Direct Anterior Approach Total Hip Arthroplasty Using a Morphometrically Optimized Femoral Stem, a Conventional Operating Table, Without Fluoroscopy. J Arthroplasty 2019; 34:327-332. [PMID: 30448326 DOI: 10.1016/j.arth.2018.10.023] [Citation(s) in RCA: 11] [Impact Index Per Article: 2.2] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 08/31/2018] [Revised: 10/12/2018] [Accepted: 10/18/2018] [Indexed: 02/06/2023] Open
Abstract
BACKGROUND Our experience with direct anterior approach total hip arthroplasty (THA) suggests that it can be performed successfully with a morphometrically optimized metaphyseal-diaphyseal engaging femoral stem (NOT a short stem), a regular operating room table (NOT a special custom table), and WITHOUT intraoperative fluoroscopy. We report our minimum 2-year results. METHODS A retrospective review of a single-surgeon series of primary direct anterior approach THAs was performed. All procedures were performed on a regular table, without fluoroscopy, using a cementless tapered femoral stem. Clinical, functional, and radiographic outcomes were evaluated at a minimum of 2 years. RESULTS In total, 1017 primary THAs were performed. The preoperative Harris Hip Score was 40.7 ± 5.1 and improved to 95.3 ± 4.2 at minimum 2-year follow-up. There were 3 dislocations (0.3%) and 15 revisions (1.5%): 7 for infection (0.7%), 4 for periprosthetic fractures (0.4%), 2 for instability (0.2%), 1 for loosening (0.1%), and 1 for pain (0.1%). Five patients (0.5%) required blood transfusion. One patient developed deep vein thrombosis and pulmonary embolism. No intraoperative fractures, perforation, or THA-related mortality occurred. Neutral stem alignment was confirmed in 98.3%. Mean cup inclination was 38.8° ± 5.1° and anteversion was 16.2° ± 3.5°. The mean leg-length discrepancy was corrected from 1.2 ± 0.2 cm preoperatively to 0.2 ± 0.1 cm postoperatively. CONCLUSION Using a morphometrically optimized metaphyseal-diaphyseal engaging tapered femoral stem instead of a short stem reduces component malposition and minimizes risk of loosening. Combining the use of this implant design and the technique and elements described in our cohort demonstrated to have excellent results at 2 years. The patients will need continued follow-up to demonstrate further durability of this device and technique compared to others performing direct anterior THA.
Collapse
Affiliation(s)
- Shaoqi Tian
- Rothman Institute, Thomas Jefferson University, Philadelphia, PA; Affiliated Hospital of Qingdao University, Qingdao, China
| | - Karan Goswami
- Rothman Institute, Thomas Jefferson University, Philadelphia, PA
| | - Jorge Manrique
- Rothman Institute, Thomas Jefferson University, Philadelphia, PA; Department of Orthopaedics & Sports Medicine, University of Washington, Seattle, WA
| | - Kier Blevins
- Rothman Institute, Thomas Jefferson University, Philadelphia, PA
| | - Ibrahim Azboy
- Rothman Institute, Thomas Jefferson University, Philadelphia, PA
| | - William J Hozack
- Rothman Institute, Thomas Jefferson University, Philadelphia, PA
| |
Collapse
|
23
|
Rutherford M, Khan RJK, Fick DP, Haebich S, Nivbrant O, Kozak T. Randomised clinical trial assessing migration of uncemented primary total hip replacement stems, with and without autologous impaction bone grafting. INTERNATIONAL ORTHOPAEDICS 2019; 43:2715-2723. [PMID: 30706087 DOI: 10.1007/s00264-019-04290-5] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 09/26/2018] [Accepted: 01/02/2019] [Indexed: 01/15/2023]
Abstract
PURPOSE Uncemented stems in primary total hip replacement (THR) are concerning in the elderly due to ectatic femoral canals and cortical thinning resulting in higher incidence of fracture and subsidence in this population. To obviate this concern, the authors developed a technique using autologous impaction bone grafting to achieve a better fitting femoral stem. The aim of this randomised clinical trial was to assess the efficacy of the technique. METHODS From 2013 to 2015, a total of 98 consecutive participants (100 primary THR procedures) were inducted into a single-institution, single-blinded, randomised clinical trial assessing, with radiostereometric analysis (RSA), the efficacy of autologous impaction bone grafting in uncemented primary THR compared with traditional uncemented primary THR technique. The primary outcome measure was femoral component migration using RSA. Secondary outcomes were post-operative proximal femoral bone density (using DEXA), hip function and quality of life using Oxford Hip Score (OHS) and Short Form-12 Health Survey (SF-12), hip pain and patient satisfaction. RESULTS There was no difference in femoral component stability (p > 0.5) or calcar resorption between the Graft and No Graft Groups at two years. There was also no difference in OHS, SF-12, pain or satisfaction between the Graft and No Graft Groups at two years (p > 0.39). CONCLUSIONS Autologous impaction bone grafting in uncemented primary THR has shown its short-term post-operative outcomes to be equivalent to standard uncemented technique, whilst offering a better fit in patients who are between femoral stem sizes. AUSTRALIAN CLINICAL TRIAL REGISTRATION NUMBER ACTRN12618000652279.
Collapse
Affiliation(s)
- Michael Rutherford
- Hollywood Private Hospital, Monash Avenue, Perth, WA, 6009, Australia. .,The Joint Studio, Suite 1/85 Monash Avenue, Perth, WA, 6009, Australia.
| | - Riaz J K Khan
- Hollywood Private Hospital, Monash Avenue, Perth, WA, 6009, Australia.,The Joint Studio, Suite 1/85 Monash Avenue, Perth, WA, 6009, Australia.,School of Medicine, University of Notre Dame Fremantle, Fremantle, WA, 6160, Australia
| | - Daniel P Fick
- Hollywood Private Hospital, Monash Avenue, Perth, WA, 6009, Australia.,The Joint Studio, Suite 1/85 Monash Avenue, Perth, WA, 6009, Australia
| | - Samantha Haebich
- The Joint Studio, Suite 1/85 Monash Avenue, Perth, WA, 6009, Australia
| | - Oscar Nivbrant
- Department of Orthopaedics, Umeå University, Umeå, Sweden
| | - Thomas Kozak
- Royal Perth Hospital, 197 Wellington St., Perth, WA, 6000, Australia
| |
Collapse
|
24
|
Abstract
Over the last two decades, several conservative femoral prostheses have been designed. The goals of conservative stems include: the spearing of the trochanteric bone stock; a more physiological loading in the proximal femur reducing the risk of stress shielding; and to avoid a long stem into the diaphysis preventing impingement with the femoral cortex and thigh pain. All stems designed to be less invasive than conventional uncemented stems are commonly named ‘short stems’. However, this term is misleading because it refers to a heterogeneous group of stems deeply different in terms of design, biomechanics and bearing. In the short-term follow-up, all conservative stems provided excellent survivorship. However, variable rates of complications were reported, including stem malalignment, incorrect stem sizing and intra-operative fracture. Radiostereometric analysis (RSA) studies demonstrated that some conservative stems were affected by an early slight migration and rotation within the first months after surgery, followed by a secondary stable fixation. Dual-energy x-ray absorptiometry (DEXA) studies demonstrated an implant-specific pattern of bone remodelling. Although the vast majority of stems demonstrated a good osseointegration, some prostheses transferred loads particularly to the lateral and distal-medial regions, favouring proximal stress shielding and bone atrophy in the great trochanter and calcar regions.
Cite this article: EFORT Open Rev 2018;3:149-159. DOI: 10.1302/2058-5241.3.170052
Collapse
Affiliation(s)
- Mattia Loppini
- Department of Biomedical Sciences, Humanitas University, Italy; Hip Diseases and Joint Replacement Surgery Unit, Humanitas Clinical and Research Center, Italy
| | - Guido Grappiolo
- Hip Diseases and Joint Replacement Surgery Unit, Humanitas Clinical and Research Center, Italy
| |
Collapse
|
25
|
Kabelitz M, Fritz Y, Grueninger P, Meier C, Fries P, Dietrich M. Cementless Stem for Femoral Neck Fractures in a Patient’s 10th Decade of Life: High Rate of Periprosthetic Fractures. Geriatr Orthop Surg Rehabil 2018; 9:2151459318765381. [PMID: 29623237 PMCID: PMC5881960 DOI: 10.1177/2151459318765381] [Citation(s) in RCA: 11] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 11/14/2017] [Revised: 01/28/2018] [Accepted: 02/15/2018] [Indexed: 01/22/2023] Open
Abstract
Background: Subsidence of cementless femoral stems in hemiarthroplasty (HA) and increased fracture rates are ongoing concerns of orthopedic surgeons when treating fractures in very old patients. Additionally, bone cement implantation syndrome may result in perioperative cardiac or pulmonary complications, especially in older patients, leading to morbidity and mortality. This study was performed to analyze possible subsidence and intraoperative fractures in a cohort of very old patients treated with cementless stems. Methods: We retrospectively analyzed a consecutive cohort of patients aged ≥90 years with femoral neck fractures treated by uncemented HA and an anterior minimally invasive approach. Immediate full-weight bearing was allowed postoperatively. Pelvic radiographs were examined for subsidence immediately postoperatively and 6 weeks later. Results: We treated 109 patients (74% women; mean age, 93 years; range, 90-102 years) by HA from January 2010 to March 2016. The 30-day mortality rate was 16%, and the morbidity rate was 47%. There were 11 (12%) intraoperative fractures: 8 (Vancouver B2) had to be addressed immediately during the primary operation, while 3 (1 Vancouver B1 and 2 Vancouver AG) were treated conservatively. One periprosthetic femoral fracture (Vancouver B1) was documented during follow-up. In 17 patients, subsidence of >2.0 mm (median, 3.9 mm; range, 2.5-9.0 mm) was documented. Conclusion: Early subsidence was low in this very old cohort treated with an uncemented stem and not showing a periprosthetic fracture. The risk of intraoperative periprosthetic fractures was high. The use of uncemented implants in osteoporotic bone continues to be an intervention with high risk and should only be performed by experienced surgeons. Level of Evidence: Level III, Therapeutic study.
Collapse
Affiliation(s)
- Method Kabelitz
- Department for Surgery, City Hospital Waid Zurich, Zurich, Switzerland
| | - Yannick Fritz
- Department for Surgery, City Hospital Waid Zurich, Zurich, Switzerland
| | | | - Christoph Meier
- Department for Surgery, Kantonsspital Winterthur, Winterthur, Switzerland
| | - Patrick Fries
- Department for Surgery, City Hospital Waid Zurich, Zurich, Switzerland
| | - Michael Dietrich
- Department for Surgery, City Hospital Waid Zurich, Zurich, Switzerland
| |
Collapse
|
26
|
Godoy-Monzon D, Buttaro M, Comba F, Zanotti G, Piccaluga F, Neira-Borrajo I. Outcomes using wedge stem with full hydroxiapatite coverage with a minimum of 5 years’ follow-up. Rev Esp Cir Ortop Traumatol (Engl Ed) 2017. [DOI: 10.1016/j.recote.2017.10.004] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/18/2022] Open
|
27
|
Godoy-Monzon D, Buttaro M, Comba F, Zanotti G, Piccaluga F, Neira-Borrajo I. Outcomes using wedge stem with full hydroxiapatite coverage with a minimum of 5 years' follow-up. Rev Esp Cir Ortop Traumatol (Engl Ed) 2017; 61:390-396. [PMID: 28917605 DOI: 10.1016/j.recot.2017.06.007] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/14/2016] [Revised: 04/28/2017] [Accepted: 06/27/2017] [Indexed: 10/18/2022] Open
Abstract
INTRODUCTION Total Hip Arthroplsty (THA) using uncemented stems is a popular practice in the last decades. The implant survivorship is crtitical and a less than 10% revision at 10 years is been propesed for commercialization and use. OBJECTIVE To analyse the clinicoradiological results of an uncemented hydroxiapatite covered wedge stem with a 5 years minimum follow up. MATERIAL AND METHODS Prospective study, patients aged from 21-75years were included. All patients received an Element stem (Exactech) and uncemented cup with crosslink poly and 32 mm metal head, and posterior approach with piriformis retention was used. Scheduled clinical and radiographic evaluation at 3 weeks, 3-6 month, year and subsequent years using Harris Hip Score and Merle d'Aubigné Postel. Intraoperative and during follow up complications were recorded. RESULTS One hundred and fourteen total hip replacements in 104 patients: 54 females and 50 males (52%/48%). Follow-up of 5.7 years (range, 5-6.2years). Average age 56.8years (range, 42-75years). Clinical evaluation the Merle d'Aubigné score improved 6.8 points and from the initianl Harris Hip Score 47.3 to 93.1 points at last follow up. Radiographic evaluation shows osteointegration in all stems. And in 6 cases (5.3% at 3 months subsidence was detected, average 1.4 mm (range 0-2.6 mm) with no clinical manifestation, 3 cases of subsidence were associated to intraoperative fractures (1 greater trochanter and 2 in the calcar area, all resolved with wire cerclaje). Subjective evaluation: 86 cases (82.6%) excellent, 9 patients (8.6%) good, 6 cases (5.9%) satisfactory and 3 cases (2.9%) poor. All poor results linked to the intraoperative complications. No patient lost during follow up period. No femoral pain dislocation or aseptic or loosening detected. All implants were in situ at last follow up. CONCLUSIONS The radiological results confirm the benefits of this type of stem with good osteointegration. The clinical and subjective results are promising. With good surgical technical and without complications the risk of aseptic loosening should be absent or minimal.
Collapse
Affiliation(s)
- D Godoy-Monzon
- Centro de Cadera Sir John Charnley, Servicio de Ortopedia y Traumatología, Hospital Italiano de Buenos Aires, Buenos Aires, Argentina.
| | - M Buttaro
- Centro de Cadera Sir John Charnley, Servicio de Ortopedia y Traumatología, Hospital Italiano de Buenos Aires, Buenos Aires, Argentina
| | - F Comba
- Centro de Cadera Sir John Charnley, Servicio de Ortopedia y Traumatología, Hospital Italiano de Buenos Aires, Buenos Aires, Argentina
| | - G Zanotti
- Centro de Cadera Sir John Charnley, Servicio de Ortopedia y Traumatología, Hospital Italiano de Buenos Aires, Buenos Aires, Argentina
| | - F Piccaluga
- Centro de Cadera Sir John Charnley, Servicio de Ortopedia y Traumatología, Hospital Italiano de Buenos Aires, Buenos Aires, Argentina
| | | |
Collapse
|
28
|
Waligora AC, Owen JR, Wayne JS, Hess SR, Golladay GJ, Jiranek WA. The Effect of Prophylactic Cerclage Wires in Primary Total Hip Arthroplasty: A Biomechanical Study. J Arthroplasty 2017; 32:2023-2027. [PMID: 28209401 DOI: 10.1016/j.arth.2017.01.019] [Citation(s) in RCA: 21] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 06/07/2016] [Revised: 11/18/2016] [Accepted: 01/15/2017] [Indexed: 02/01/2023] Open
Abstract
BACKGROUND Despite literature to support the use of various cerclage techniques to address intraoperative femoral fractures in total hip arthroplasty, there are limited data to support prophylactic cerclage wiring of the femur during cementless implant placement. This study aims to evaluate the effect of prophylactic calcar cerclage wires on the biomechanical parameters required to produce periprosthetic femoral fractures and on the morphology of these fracture patterns in stable cementless femoral implants. METHODS Ten pairs of matched fresh frozen cadaveric femurs were implanted with anatomic tapered cementless implants with or without the addition of 2 monofilament calcar wires. Specimens were axially loaded and externally rotated to failure. Initial torsional stiffness, rotation and energy to failure, and torque at failure were measured. Statistical significance was set at P < .05. Fracture patterns were classified according to a well-known classification system. RESULTS Wired specimens required significantly more rotation (P = .039) and energy to failure (P = .048). No significant difference was detected in initial torsional stiffness (P = .63) or torque at failure (P = .10). All unwired samples developed a Vancouver B2 fracture pattern. Seven of the 8 wired specimens also developed a Vancouver B2 fracture pattern, while the eighth wired specimen developed a Vancouver B1 fracture pattern. CONCLUSION Prophylactic cerclage wire placement increases the rotation and energy to failure in well-fixed press-fit femoral implants. The increase in torsional energy needed for failure may reduce the risk of early periprosthetic fracture. Further studies are needed to evaluate cost vs benefit and long-term outcomes of prophylactic wiring. Based on the results of our study, consideration of prophylactic wiring should be addressed on a case-to-case basis.
Collapse
Affiliation(s)
- Andrew C Waligora
- Department of Orthopaedic Surgery and Biomedical Engineering, Orthopaedic Research Laboratory, Virginia Commonwealth University, Richmond, Virginia
| | - John R Owen
- Department of Orthopaedic Surgery and Biomedical Engineering, Orthopaedic Research Laboratory, Virginia Commonwealth University, Richmond, Virginia
| | - Jennifer S Wayne
- Department of Orthopaedic Surgery and Biomedical Engineering, Orthopaedic Research Laboratory, Virginia Commonwealth University, Richmond, Virginia
| | - Shane R Hess
- Department of Orthopaedic Surgery and Biomedical Engineering, Orthopaedic Research Laboratory, Virginia Commonwealth University, Richmond, Virginia
| | - Gregory J Golladay
- Department of Orthopaedic Surgery and Biomedical Engineering, Orthopaedic Research Laboratory, Virginia Commonwealth University, Richmond, Virginia
| | - William A Jiranek
- Department of Orthopaedic Surgery and Biomedical Engineering, Orthopaedic Research Laboratory, Virginia Commonwealth University, Richmond, Virginia
| |
Collapse
|
29
|
Sivananthan S, Lim CT, Narkbunnam R, Sox-Harris A, Huddleston JI, Goodman SB. Revision Hip Arthroplasty Using a Modular, Cementless Femoral Stem: Intermediate-Term Follow-Up. J Arthroplasty 2017; 32:1245-1249. [PMID: 27923596 DOI: 10.1016/j.arth.2016.10.033] [Citation(s) in RCA: 20] [Impact Index Per Article: 2.9] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 10/19/2016] [Accepted: 10/25/2016] [Indexed: 02/01/2023] Open
Abstract
BACKGROUND Modular femoral stem provides flexibility in femoral reconstruction, ensuring improved "fit and fill". However, there are risks of junction failure and corrosion, as well as cost concerns in the use of modular femoral stems. METHODS We reviewed prospectively-gathered clinical and radiographic data on revision total hip arthroplasties (THAs) performed from 2001-2007 using modular, cementless femoral component performed by the 2 senior authors. Patients with a minimum follow-up of 7 years were included in this study. RESULTS Sixty-four patients (68 hips) with a median age of 68 ± 14 years (range 40-92 years) at revision THA were included. The median follow-up was 11.0 ± 1.8 years (range 7-14). Harris hip score, femoral stem subsidence, and stem osseointegration were recorded. The Harris hip score improved from an average of 38.1-80.1 (P < .01). Five hips had one or more dislocations. Seven patients underwent reoperations, 3 of which did not involve the stem. Four stems required revision because of infection, recurrent dislocation, or suboptimal implant position. Survival rates for any reasons and revision for femoral stems were 90% and 94%, respectively, at the most recent follow-up. Four stems subsided more than 5 mm, but established stable osseointegration thereafter. Seven nonloose stems (10.2%) demonstrated radiolucent lines in Gruen zones 1 and 7. No complications regarding the modular junction were encountered. CONCLUSION Modular, cementless, extensively porous-coated femoral components have demonstrated intermediate-term clinical and radiographic success. Initial distal intramedullary fixation ensures stability, and proximal modularity further maximizes fit and fill.
Collapse
Affiliation(s)
- Sureshan Sivananthan
- Department of Orthopaedic Surgery, Stanford University School of Medicine, Redwood City, California
| | - Chin-Tat Lim
- Department of Orthopaedic Surgery, Stanford University School of Medicine, Redwood City, California; Department of Orthopaedic Surgery, National University Hospital, Singapore
| | - Rapeepat Narkbunnam
- Department of Orthopaedic Surgery, Stanford University School of Medicine, Redwood City, California
| | - Alex Sox-Harris
- Department of Orthopaedic Surgery, Stanford University School of Medicine, Redwood City, California
| | - James I Huddleston
- Department of Orthopaedic Surgery, Stanford University School of Medicine, Redwood City, California
| | - Stuart B Goodman
- Department of Orthopaedic Surgery, Stanford University School of Medicine, Redwood City, California
| |
Collapse
|
30
|
Castellini I, Andreani L, Parchi PD, Bonicoli E, Piolanti N, Risoli F, Lisanti M. Hydroxyapatite in total hip arthroplasty. Our experience with a plasma spray porous titanium alloy/hydroxyapatite double-coated cementless stem. ACTA ACUST UNITED AC 2017; 13:221-227. [PMID: 28228786 DOI: 10.11138/ccmbm/2016.13.3.221] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/29/2023]
Abstract
PURPOSE Total hip arthroplasty could fail due to many factors and one of the most common is the aseptic loosening. In order to achieve an effective osseointegration and reduce risk of lossening, the use of cemented implant, contact porous bearing surface and organic coating were developed. Aim of this study was to evaluate clinical and radiological mid-term outcomes of a porous titanium alloy/hydroxyapatite double coating manufactured cementless femoral stem applied with "plasma spray" technique and to demonstrate the possibility to use this stem in different types of femoral canals. METHODS Between January 2008 and December 2012, 240 consecutive primary total hip arthroplasties (THAs) were performed using a porous titanium alloy/hydroxyapatite double coating manufactured cementless femoral stem. 182 patients were examined: 136 were females (74.7%) and 46 males (25.2%); average age was 72 years old (ranging from 26 to 92 years old). For each patient, Harris Hip Scores (HHS) and Womac Scores were collected. All X-ray images were analyzed in order to demonstrate stem survival rate and subsidence. RESULTS Harris Hip Score was good or excellent in 85% of the cases (average 90%) and mean WOMAC score was 97.5 (ranging from 73.4 to 100). No cases of early/late infection or periprosthetic fracture were noticed, with an excellent implant survival rate (100%) in a mean period of 40 months (ranging from 24 and 84 months). 5 cases presented acute implant dislocation, 2 due to wrong cup positioning in a dysplastic acetabulum and 3 after ground level fall. Dorr classification of femoral geometry was uses and the results were: 51 type A bone, 53 type B bone and 78 type C bone. Stem subsidence over 2 mm was considered as a risk factor of future implant loosening and was evidenced in 3 female patients with type C of Dorr classification. No radiolucencies signs around the proximally coated portion of stem or proximal reabsorption were visible during the radiographic follow-up. CONCLUSIONS Concerning the use of porous titanium alloy/hydroxyapatite double coating, this study reported an excellent implant survival rate in a mid-term period with a rate of 1,64% of subsidence in patients with type C of femoral canal but with an optimal HHS and Womac Score results. Regarding this stem, primary stability is guaranteed by trapezoid shape of proximal region and tapering in frontal plane through press-fit technique. Radiological absence of pedestal has been accepted as sign of no excessive stress transmission to distal cortex due to its tapered diaphyseal region. Thanks to the reported data, Authors can consider this double coating a valid choice with an excellent medium-term survival and encouraging subsidence results. Further studies are needed to ensure these results can be replicated.
Collapse
Affiliation(s)
- Iacopo Castellini
- Orthopaedics and Traumatology 1st Department, University of Pisa, Pisa, Italy
| | - Lorenzo Andreani
- Orthopaedics and Traumatology 1st Department, University of Pisa, Pisa, Italy
| | | | - Enrico Bonicoli
- Orthopaedics and Traumatology 1st Department, University of Pisa, Pisa, Italy
| | - Nicola Piolanti
- Orthopaedics and Traumatology 1st Department, University of Pisa, Pisa, Italy
| | - Francesca Risoli
- Orthopaedics and Traumatology 1st Department, University of Pisa, Pisa, Italy
| | - Michele Lisanti
- Orthopaedics and Traumatology 1st Department, University of Pisa, Pisa, Italy
| |
Collapse
|
31
|
Kutzner KP, Freitag T, Donner S, Kovacevic MP, Bieger R. Outcome of extensive varus and valgus stem alignment in short-stem THA: clinical and radiological analysis using EBRA-FCA. Arch Orthop Trauma Surg 2017; 137:431-439. [PMID: 28154993 PMCID: PMC5310617 DOI: 10.1007/s00402-017-2640-z] [Citation(s) in RCA: 61] [Impact Index Per Article: 8.7] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 07/25/2016] [Indexed: 12/21/2022]
Abstract
INTRODUCTION The principle of implanting a calcar-guided short stem consists of an individual alignment alongside the medial calcar providing the ability of reconstructing varus and valgus anatomy in a great variety. However, still, there are broad concerns about the safety of extensive varus and valgus positioning in regard to stability, bony alterations, and periprosthetic fractures. MATERIALS AND METHODS 216 total hip arthroplasties using a calcar-guided short stem (optimys, Mathys Ltd.) in 162 patients were included. Depending on postoperative CCD angle, hips were divided into five groups (A-E). Varus- and valgus tilt and axial subsidence were assessed by "Einzel-Bild-Roentgen-Analyse"(EBRA-FCA, femoral component analysis) over a 2-year follow-up. The incidence of stress-shielding and cortical hypertrophy as well as clinical outcome [Harris Hip Score (HHS)] were reported. RESULTS Postoperative CCD angles ranged from 117.9° to 145.6° and mean postoperative CCD angles in group A-E were 123.3°, 128.0°, 132.4°, 137.5°, and 142.5°, respectively. After 2 years, the mean varus/valgus tilt was -0.16°, 0.37°, 0.48°, 0.01°, and 0.86°, respectively (p = 0.502). Axial subsidence after 2 years was 1.20, 1.02, 1.44, 1.50, and 2.62 mm, respectively (p = 0.043). No periprosthetic fractures occurred and none of the stems had to be revised. Rates of stress-shielding and cortical hypertrophy as well as HHS showed no significant difference between the groups. CONCLUSIONS Valgus alignment results in increased subsidence but does not affect the clinical outcome. There is no difference in stress shielding and cortical hypertrophy between the groups. The authors recommend long term monitoring of valgus aligned stems.
Collapse
Affiliation(s)
- Karl Philipp Kutzner
- Department of Orthopaedic Surgery and Traumatology, St. Josefs Hospital Wiesbaden, Beethovenstr. 20, 65189 Wiesbaden, Germany
| | - Tobias Freitag
- Department of Orthopaedic Surgery, University of Ulm, Oberer Eselsberg 45, 89081 Ulm, Germany
| | - Stefanie Donner
- Department of Orthopaedic Surgery and Traumatology, St. Josefs Hospital Wiesbaden, Beethovenstr. 20, 65189 Wiesbaden, Germany
| | - Mark Predrag Kovacevic
- Department of Traumatology, Hand- and Orthopaedic Surgery, HELIOS Dr. Horst Schmidt Clinic Wiesbaden, Ludwig-Erhard-Str. 100, 65199 Wiesbaden, Germany
| | - Ralf Bieger
- Department of Orthopaedic Surgery, University of Ulm, Oberer Eselsberg 45, 89081 Ulm, Germany
| |
Collapse
|
32
|
Shin YS, Suh DH, Park JH, Kim JL, Han SB. Comparison of Specific Femoral Short Stems and Conventional-Length Stems in Primary Cementless Total Hip Arthroplasty. Orthopedics 2016; 39:e311-7. [PMID: 26913760 DOI: 10.3928/01477447-20160222-04] [Citation(s) in RCA: 25] [Impact Index Per Article: 3.1] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 04/06/2015] [Accepted: 09/01/2015] [Indexed: 02/03/2023]
Abstract
There are several reported disadvantages with conventional-length femoral stems in cementless total hip arthroplasty (THA). Therefore, various efforts have been made to develop a specific femoral short stem to improve physiologic bone remodeling at the femoral aspect of a cementless THA. However, there are potential disadvantages with specific femoral short stems, such as malalignment, inadvertent subsidence, and potential proximal femoral fracture. Therefore, the authors quantitatively compared radiographic and clinical outcomes as well as component-specific complications between 2 groups of patients following primary cementless THA. A matched comparison was made between specific femoral short stems (n=50) and conventional-length femoral stems (n=50) in cementless THA procedures performed between January 2008 and January 2012. Patients were matched for age, sex, body mass index, height, surgical approach, and surgeon. No significant differences were found between the 2 groups in mean postoperative radiographic outcomes, functional outcomes, or complications. Both groups showed satisfactory performance at 5-year follow-up. Specific femoral short stems resulted in a higher incidence of malalignment and subsidence and a lower incidence of thigh pain and proximal bone resorption compared with conventional-length femoral stems. Although longer follow-up is required, specific femoral short stems may have clinical and radiographic advantages with equivalent perioperative complications relative to conventional-length femoral stems. However, this technique requires proper patient selection in combination with careful preoperative planning and meticulous surgical technique.
Collapse
|
33
|
Siepen W, Zwicky L, Stoffel KK, Ilchmann T, Clauss M. Prospective two-year subsidence analysis of 100 cemented polished straight stems - a short-term clinical and radiological observation. BMC Musculoskelet Disord 2016; 17:395. [PMID: 27640188 PMCID: PMC5027091 DOI: 10.1186/s12891-016-1247-9] [Citation(s) in RCA: 9] [Impact Index Per Article: 1.1] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 04/09/2016] [Accepted: 09/09/2016] [Indexed: 01/14/2023] Open
Abstract
Background Cemented stems show good long-term results and the survival of new implants can be predicted by their early subsidence. With EBRA-FCA (Femoral Component Analysis using Einzel-Bild-Röntgen-Analyse) early subsidence as an early indicator for later aseptic loosening can be analysed. For the cemented TwinSys stem mid- and long-term data is only avalible from the New Zeeland Arthroplasty register, thus close monitoring of this implant system is still mandatory. Methods We conducted a 2 year follow up of 100 consecutive hybrid THA (Total hip arthroplasty) of a series of 285 primary THA operated between Jan 2009 und Oct 2010. These 100 received a polished, cemented collarless straight stem (twinSys®, Mathys AG® Bettlach, Switzerland) with an uncemented monobloc pressfit cup (RM pressfit®, Mathys AG® Bettlach, Switzerland). The other patients were treated with the uncemented version of this stem and the same cup. Clinical (Harris Hip Score) and radiological (ap and axial x-rays, cementing quality according to Barrack, alignment) outcomes besides an EBRA-FCA subsidence analysis were performed. Results Median age at operation was 78 (68 to 93) years. 5 patients died in the course of follow-up unrelated to surgery. The KM (Kaplan-Meier) survival at 2 years for the endpoint reoperation for any reason was 94.9 (95 % confidence interval 90.6–100 %). Survival for the endpoint aseptic loosening at 2 years was 100 %. The HHS (Harris Hip Score) improved from 56 (14–86) preoperatively to 95 (60–100) 2 years after the operation. Cementing results were judged 47 % Grade A, 45 % Grade B and 7 % Grade C. Osteolysis was found in 2 stems without clinical symptoms or correlation to subsidence or cementing quality. The EBRA-FCA analysis showed an average subsidence of -0.30 mm (95 % CI -0.5 mm to -0.1 mm). 11 patients showed a subsidence of more than 1 mm. In this group one patient showed a subsidence of 1.5 mm and one of 3.1 mm without further radiological changes. Conclusions The twinSys stem showed excellent clinical and radiologic short term results at 2 years follow-up and seems to be a reliable implant.
Collapse
Affiliation(s)
- Wolf Siepen
- Department for Orthopaedics and Trauma Surgery, Kantonsspital Baselland, CH-4410, Liestal, Switzerland.
| | - Lukas Zwicky
- Department for Orthopaedics and Trauma Surgery, Kantonsspital Baselland, CH-4410, Liestal, Switzerland
| | - Karl Kilian Stoffel
- Department for Orthopaedics and Trauma Surgery, Kantonsspital Baselland, CH-4410, Liestal, Switzerland
| | - Thomas Ilchmann
- LEONARDO, Hirslanden Klinik Birshof, Münchenstein, Switzerland
| | - Martin Clauss
- Department for Orthopaedics and Trauma Surgery, Kantonsspital Baselland, CH-4410, Liestal, Switzerland
| |
Collapse
|
34
|
Gabarre S, Herrera A, Ibarz E, Mateo J, Gil-Albarova J, Gracia L. Comparative Analysis of the Biomechanical Behaviour of Two Cementless Short Stems for Hip Replacement: Linea Anatomic and Minihip. PLoS One 2016; 11:e0158411. [PMID: 27391328 PMCID: PMC4938462 DOI: 10.1371/journal.pone.0158411] [Citation(s) in RCA: 14] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/24/2015] [Accepted: 06/15/2016] [Indexed: 12/18/2022] Open
Abstract
A comparative study between two stems (Linea Anatomic and Minihip) has been performed in order to analyse the differences in their biomechanical behaviour, concerning stem micromotions and load transmission between stem and bone. From the corresponding finite element models, a parametric study was carried out to quantify ranges of micromotions taking into account: friction coefficient in the stem-bone interface, press-fit and two types of gait cycle. Micromotions were evaluated for each stem at six different levels along repeated gait cycles. An initial and marked stem subsidence at the beginning of the simulation was observed, followed by an asymptotic decrease due to friction forces. Once migration occurs, a repeated reversible cyclic micromotion is developed and stabilized as gait cycle times are simulated. The general motion pattern exhibited higher amplitude of micromotion for Minihip compared to Linea stem. The load transmission mechanism was analyzed, identifying the main internal forces. The results show higher local forces for Minihip stem up to 80% greater than for Linea stem. The differences of design between Minihip and Linea conditioned different distributions of load, influencing the posterior stress-shielding. Consequently, short stems require high bone stock and quality should, being indicated for young patients with high bone quality.
Collapse
Affiliation(s)
- Sergio Gabarre
- Department of Mechanical Engineering, University of Zaragoza, Zaragoza, Spain
- Aragón Institute for Engineering Research, Zaragoza, Spain
| | - Antonio Herrera
- Department of Surgery, University of Zaragoza, Zaragoza, Spain
- Aragón Health Sciences Institute, Zaragoza, Spain
- * E-mail:
| | - Elena Ibarz
- Department of Mechanical Engineering, University of Zaragoza, Zaragoza, Spain
- Aragón Institute for Engineering Research, Zaragoza, Spain
| | - Jesús Mateo
- Department of Surgery, University of Zaragoza, Zaragoza, Spain
- Aragón Health Sciences Institute, Zaragoza, Spain
- Department of Orthopaedic Surgery and Traumatology, Miguel Servet University Hospital, Zaragoza, Spain
| | - Jorge Gil-Albarova
- Department of Surgery, University of Zaragoza, Zaragoza, Spain
- Aragón Health Sciences Institute, Zaragoza, Spain
- Department of Orthopaedic Surgery and Traumatology, Miguel Servet University Hospital, Zaragoza, Spain
| | - Luis Gracia
- Department of Mechanical Engineering, University of Zaragoza, Zaragoza, Spain
- Aragón Institute for Engineering Research, Zaragoza, Spain
| |
Collapse
|
35
|
Al-Najjim M, Khattak U, Sim J, Chambers I. Differences in subsidence rate between alternative designs of a commonly used uncemented femoral stem. J Orthop 2016; 13:322-6. [PMID: 27436922 DOI: 10.1016/j.jor.2016.06.026] [Citation(s) in RCA: 45] [Impact Index Per Article: 5.6] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 05/25/2016] [Accepted: 06/27/2016] [Indexed: 11/19/2022] Open
Abstract
INTRODUCTION Measurement of early subsidence of uncemented femoral stems can be used to evaluate the likelihood of long term stem component loosening and therefore clinical failure. Our aim was to evaluate the factors associated with subsidence in collared and uncollared versions of the Corail femoral stem. METHODS 121 hips in 113 consecutive patients were studied, operated on by two surgeons in our hospital differing in their choice of Corail stem. This gave two groups of patients with 66 hips having collared stems and 55 hips having uncollared. We recorded patients' age, sex, ASA grade and BMI. Radiographs post-operatively at day 1, 6 weeks and 1 year were evaluated measuring subsidence, angulation, signs of stability and fixation, and canal fill ratio at the metaphysis and diaphysisafter correcting for magnification errors by calibration using femoral head size. RESULTS Clinically significant subsidence (>3 mm) occurred in 7.6% of collared and 10.9% of uncollared stems, all within 6-8 weeks, but did not reach statistical significance (p = 0.345). Revision for symptomatic loosening was required in 1 patient in each group (1.5% collared versus 1.8% uncollared). DISCUSSION Early subsidence of Corail femoral stem should alert surgeons to closer patient follow-up as the rate of early revision is 18% in stems with >3 mm of subsidence. However, the presence of a collar does not seem to be protective.
Collapse
|
36
|
Streit MR, Haeussler D, Bruckner T, Proctor T, Innmann MM, Merle C, Gotterbarm T, Weiss S. Early Migration Predicts Aseptic Loosening of Cementless Femoral Stems: A Long-term Study. Clin Orthop Relat Res 2016; 474:1697-706. [PMID: 27130649 PMCID: PMC4887381 DOI: 10.1007/s11999-016-4857-5] [Citation(s) in RCA: 55] [Impact Index Per Article: 6.9] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 09/22/2015] [Accepted: 04/19/2016] [Indexed: 01/31/2023]
Abstract
BACKGROUND Excessive early migration of cemented stems and cups after THA has been associated with poor long-term survival and allows predictable evaluation of implant performance. However, there are few data regarding the relationship between early migration and aseptic loosening of cementless femoral components, and whether early migration might predict late failure has not been evaluated, to our knowledge. Einzel-Bild-Röntgen-Analyse-femoral component analysis (EBRA-FCA) is a validated technique to accurately measure axial femoral stem migration without the need for tantalum markers, can be performed retrospectively, and may be a suitable tool to identify poor performing implants before their widespread use. QUESTIONS/PURPOSES We asked: (1) Is axial migration within the first 24 months as assessed by EBRA-FCA greater among cementless stems that develop aseptic loosening than those that remain well fixed through the second decade; (2) what is the diagnostic performance of implant migration at 24 months postoperatively to predict later aseptic loosening of these components; and (3) how does long-term stem survivorship compare between groups with high and low early migration? METHODS We evaluated early axial stem migration in 158 cementless THAs using EBRA-FCA. The EBRA-FCA measurements were performed during the first week postoperatively (baseline measurement) and at regular followups of 3, 6, and 12 months postoperatively and annually thereafter. The mean duration of followup was 21 years (range, 18-24 years). The stems studied represented 45% (158 of 354) of the cementless THAs performed during that time, and cementless THAs represented 34% (354 of 1038) of the THA practice during that period. No patient enrolled in this study was lost to followup. Multivariate survivorship analysis using Cox's regression model was performed with an endpoint of aseptic loosening of the femoral component. Loosening was defined according to the criteria described by Engh et al. and assessed by two independent observers. Patients with a diagnosis of prosthetic joint infection were excluded. Receiver operating characteristic (ROC) curve analysis was used to evaluate diagnostic performance of axial stem migration 1, 2, 3, and 4 years postoperatively as a predictor of aseptic loosening. Survivorship of hips with high (≥ 2.7 mm) and low (< 2.7 mm) migration was compared using a competing-events analysis. RESULTS Femoral components that had aseptic loosening develop showed greater mean distal migration at 24 months postoperatively than did components that remained well fixed throughout the surveillance period (4.2 mm ± 3.1 mm vs 0.8 mm ± 0.9 mm; mean difference, 3.4 mm, 95% CI, 2.5-4.4; p ≤ 0.001). Distal migration at 24 months postoperatively was a strong risk factor for aseptic loosening (hazard ratio, 1.98; 95% CI, 1.51-2.57; p < 0.001). The associated overall diagnostic performance of 2-year distal migration for predicting aseptic loosening was good (area under the ROC curve, 0.86; 95% CI, 0.72-1.00; p < 0.001). Sensitivity of early migration measurement was high for the prediction of aseptic loosening during the first decade after surgery but decreased markedly thereafter. Stems with large amounts of early migration (≥ 2.7 mm) had lower 18-year survivorship than did stems with little early migration (29% [95% CI, 0%-62%] versus 95% [95% CI, 90%-100%] p < 0.001). CONCLUSIONS Early migration, as measured by EBRA-FCA at 2 years postoperatively, has good diagnostic capabilities for detection of uncemented femoral components at risk for aseptic loosening during the first and early second decades after surgery. However, there was no relationship between early migration patterns and aseptic loosening during the late second and third decades. EBRA-FCA can be used as a research tool to evaluate new cementless stems or in clinical practice to evaluate migration patterns in patients with painful femoral components. LEVEL OF EVIDENCE Level III, diagnostic study.
Collapse
Affiliation(s)
- Marcus R. Streit
- Clinic of Orthopaedic and Trauma Surgery, Center for Orthopaedics, Trauma Surgery and Spinal Cord Injury, University of Heidelberg, Schlierbacher Landstrasse 200a, 69118 Heidelberg, Germany
| | - Daniel Haeussler
- Clinic of Orthopaedic and Trauma Surgery, Center for Orthopaedics, Trauma Surgery and Spinal Cord Injury, University of Heidelberg, Schlierbacher Landstrasse 200a, 69118 Heidelberg, Germany
| | - Thomas Bruckner
- Institute of Medical Biometry and Informatics, University of Heidelberg, Heidelberg, Germany
| | - Tanja Proctor
- Institute of Medical Biometry and Informatics, University of Heidelberg, Heidelberg, Germany
| | - Moritz M. Innmann
- Clinic of Orthopaedic and Trauma Surgery, Center for Orthopaedics, Trauma Surgery and Spinal Cord Injury, University of Heidelberg, Schlierbacher Landstrasse 200a, 69118 Heidelberg, Germany
| | - Christian Merle
- Clinic of Orthopaedic and Trauma Surgery, Center for Orthopaedics, Trauma Surgery and Spinal Cord Injury, University of Heidelberg, Schlierbacher Landstrasse 200a, 69118 Heidelberg, Germany
| | - Tobias Gotterbarm
- Clinic of Orthopaedic and Trauma Surgery, Center for Orthopaedics, Trauma Surgery and Spinal Cord Injury, University of Heidelberg, Schlierbacher Landstrasse 200a, 69118 Heidelberg, Germany
| | - Stefan Weiss
- Clinic of Orthopaedic and Trauma Surgery, Center for Orthopaedics, Trauma Surgery and Spinal Cord Injury, University of Heidelberg, Schlierbacher Landstrasse 200a, 69118 Heidelberg, Germany ,Department of Joint Replacement Surgery, ARCUS Kliniken Pforzheim, Pforzheim, Germany
| |
Collapse
|
37
|
Malak TT, Broomfield JAJ, Palmer AJR, Hopewell S, Carr A, Brown C, Prieto-Alhambra D, Glyn-Jones S. Surrogate markers of long-term outcome in primary total hip arthroplasty: A systematic review. Bone Joint Res 2016; 5:206-14. [PMID: 27267795 PMCID: PMC4921042 DOI: 10.1302/2046-3758.56.2000568] [Citation(s) in RCA: 25] [Impact Index Per Article: 3.1] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 09/17/2015] [Accepted: 03/23/2016] [Indexed: 12/24/2022] Open
Abstract
Objectives High failure rates of metal-on-metal hip arthroplasty implants have highlighted the need for more careful introduction and monitoring of new implants and for the evaluation of the safety of medical devices. The National Joint Registry and other regulatory services are unable to detect failing implants at an early enough stage. We aimed to identify validated surrogate markers of long-term outcome in patients undergoing primary total hip arthroplasty (THA). Methods We conducted a systematic review of studies evaluating surrogate markers for predicting long-term outcome in primary THA. Long-term outcome was defined as revision rate of an implant at ten years according to National Institute of Health and Care Excellence guidelines. We conducted a search of Medline and Embase (OVID) databases. Separate search strategies were devised for the Cochrane database and Google Scholar. Each search was performed to include articles from the date of their inception to June 8, 2015. Results Our search strategy identified 1082 studies of which 115 studies were included for full article review. Following review, 17 articles were found that investigated surrogate markers of long-term outcome. These included one systematic review, one randomised control trial (RCT), one case control study and 13 case series. Validated surrogate markers included Radiostereometric Analysis (RSA) and Einzel-Bild-Röntgen-Analyse (EBRA), each measuring implant migration and wear. We identified five RSA studies (one systematic review and four case series) and four EBRA studies (one RCT and three case series). Patient Reported Outcome Measures (PROMs) at six months have been investigated but have not been validated against long-term outcomes. Conclusions This systematic review identified two validated surrogate markers of long-term primary THA outcome: RSA and EBRA, each measuring implant migration and wear. We recommend the consideration of RSA in the pre-market testing of new implants. EBRA can be used to investigate acetabular wear but not femoral migration. Further studies are needed to validate the use of PROMs for post-market surveillance. Cite this article: T. T. Malak, J. A. J. Broomfield, A. J. R. Palmer, S. Hopewell, A. Carr, C. Brown, D. Prieto-Alhambra, S. Glyn-Jones. Surrogate markers of long-term outcome in primary total hip arthroplasty: A systematic review. Bone Joint Res 2016;5:206–214. DOI: 10.1302/2046-3758.56.2000568.
Collapse
Affiliation(s)
- T T Malak
- Oxford NIHR Musculoskeletal Biomedical Research Unit, Nuffield Department of Orthopaedics, Rheumatology and Musculoskeletal Sciences, University of Oxford, Windmill Lane, Oxford OX3 7LD, UK
| | - J A J Broomfield
- Oxford NIHR Musculoskeletal Biomedical Research Unit, Nuffield Department of Orthopaedics, Rheumatology and Musculoskeletal Sciences, University of Oxford, Windmill Lane, Oxford OX3 7LD, UK
| | - A J R Palmer
- Oxford NIHR Musculoskeletal Biomedical Research Unit, Nuffield Department of Orthopaedics, Rheumatology and Musculoskeletal Sciences, University of Oxford, Windmill Lane, Oxford OX3 7LD, UK
| | - S Hopewell
- Oxford NIHR Musculoskeletal Biomedical Research Unit, Nuffield Department of Orthopaedics, Rheumatology and Musculoskeletal Sciences, University of Oxford, Windmill Lane, Oxford OX3 7LD, UK
| | - A Carr
- Oxford NIHR Musculoskeletal Biomedical Research Unit, Nuffield Department of Orthopaedics, Rheumatology and Musculoskeletal Sciences, University of Oxford, Windmill Lane, Oxford OX3 7LD, UK
| | - C Brown
- Oxford NIHR Musculoskeletal Biomedical Research Unit, Nuffield Department of Orthopaedics, Rheumatology and Musculoskeletal Sciences, University of Oxford, Windmill Lane, Oxford OX3 7LD, UK
| | - D Prieto-Alhambra
- Oxford NIHR Musculoskeletal Biomedical Research Unit, Nuffield Department of Orthopaedics, Rheumatology and Musculoskeletal Sciences, University of Oxford, Windmill Lane, Oxford OX3 7LD, UK
| | - S Glyn-Jones
- Oxford NIHR Musculoskeletal Biomedical Research Unit, Nuffield Department of Orthopaedics, Rheumatology and Musculoskeletal Sciences, University of Oxford, Windmill Lane, Oxford OX3 7LD, UK
| |
Collapse
|
38
|
Nebergall AK, Rolfson O, Rubash HE, Malchau H, Troelsen A, Greene ME. Stable Fixation of a Cementless, Proximally Coated, Double Wedged, Double Tapered Femoral Stem in Total Hip Arthroplasty: A 5-Year Radiostereometric Analysis. J Arthroplasty 2016; 31:1267-1274. [PMID: 26725135 DOI: 10.1016/j.arth.2015.11.036] [Citation(s) in RCA: 10] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 07/28/2015] [Revised: 11/19/2015] [Accepted: 11/20/2015] [Indexed: 02/01/2023] Open
Abstract
BACKGROUND The objective of this 5-year prospective study of 51 hips was to assess migration of a cementless tapered femoral stem using radiostereometric analysis (RSA), plain radiographs (radiolucencies), and patient-reported outcome measures (PROMs). METHODS Forty-seven patients (51 hips) agreed to participate in this prospective RSA study. All patients received a Taperloc stem. Tantalum beads were inserted into the femoral bone surrounding the stem to measure migration using RSA. RSA films, plain radiograph, and PROM follow-up were obtained immediately after surgery, 6 months, 1, 2, 3, and 5 years after surgery. RESULTS The median (interquartile range) subsidence was 0.03 mm (-0.23 to 0.06) at 5 years, with no significant differences over time. Four outlier stems had >1.5 mm of subsidence by 1 year. No stem showed radiolucencies in more than 3 zones during the 5 years. All PROMs remained favorable at 5 years, suggesting an excellent outcome. There were no stems revised for mechanical loosening; 1 stem was revised for an infection. CONCLUSION After initial settling, the cementless tapered femoral stems in our series were stable. The 4 outlier stems with >1.5 mm of subsidence by 1 year remain stable at 5 years. RSA was the most sensitive method of detection for stems at greater risk for potential future failure. This report adds contributions to the positive results associated with this type of fixation. The results at 5 years showed excellent midterm survivorship in this cohort with a cementless tapered femoral component.
Collapse
Affiliation(s)
- Audrey K Nebergall
- Department of Orthopaedics, Harris Orthopaedic Laboratory, Massachusetts General Hospital, Boston, Massachusetts
| | - Ola Rolfson
- Department of Orthopaedics, Harris Orthopaedic Laboratory, Massachusetts General Hospital, Boston, Massachusetts; Department of Orthopaedics, Institute of Clinical Sciences at Sahlgrenska Academy, University of Gothenburg, Gothenburg, Sweden
| | - Harry E Rubash
- Department of Orthopaedics, Harris Orthopaedic Laboratory, Massachusetts General Hospital, Boston, Massachusetts
| | - Henrik Malchau
- Department of Orthopaedics, Harris Orthopaedic Laboratory, Massachusetts General Hospital, Boston, Massachusetts
| | - Anders Troelsen
- Department of Orthopaedics, Harris Orthopaedic Laboratory, Massachusetts General Hospital, Boston, Massachusetts; Department of Orthopedics, Copenhagen University Hvidovre Hospital, Hvidovre, Denmark
| | - Meridith E Greene
- Department of Orthopaedics, Harris Orthopaedic Laboratory, Massachusetts General Hospital, Boston, Massachusetts
| |
Collapse
|
39
|
Boettner F, Sculco P, Lipman J, Renner L, Faschingbauer M. A novel method to measure femoral component migration by computed tomography: a cadaver study. Arch Orthop Trauma Surg 2016; 136:857-63. [PMID: 26983723 DOI: 10.1007/s00402-016-2442-8] [Citation(s) in RCA: 6] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 10/05/2015] [Indexed: 11/25/2022]
Abstract
INTRODUCTION Radiostereometric analysis (RSA) is the most accurate technique to measure implant migration. However, it requires special equipment, technical expertise and analysis software and has not gained wide acceptance. The current paper analyzes a novel method to measure implant migration utilizing widely available computer tomography (CT). METHODS Three uncemented total hip replacements were performed in three human cadavers and six tantalum beads were inserted into the femoral bone similar to RSA. Six different 28 mm heads (-3, 0, 2.5, 5.0, 7.5 and 10 mm) were added to simulate five reproducible translations (maximum total point migration) of the center of the head. Implant migration was measured in a 3-D analysis software (Geomagic Studio 7). Repeat manual reconstructions of the center of the head were performed by two investigators to determine repeatability and accuracy. RESULTS The accuracy of measurements between the centers of two head sizes was 0.11 mm with a CI 95 % of 0.22 mm. The intra-observer repeatability was 0.13 mm (CI 95 % 0.25 mm). The interrater-reliability was 0.943. CONCLUSION CT based measurement of head displacement in a cadaver model were highly accurate and reproducible.
Collapse
|
40
|
One-stage bilateral versus unilateral short-stem total hip arthroplasty: comparison of migration patterns using "Ein-Bild-Roentgen-Analysis Femoral-Component-Analysis". INTERNATIONAL ORTHOPAEDICS 2016; 41:61-66. [PMID: 27075867 DOI: 10.1007/s00264-016-3184-5] [Citation(s) in RCA: 11] [Impact Index Per Article: 1.4] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 12/09/2015] [Accepted: 03/27/2016] [Indexed: 12/22/2022]
Abstract
PURPOSE The hypothesis of this study was that femoral implant migration would not differ between simultaneous bilateral or unilateral short-stem THA. METHOD Implant migration of 202 femoral short-stems (100 unilateral and 102 one-stage bilateral cases) in 151 patients was assessed by "Ein-Bild-Roentgen-Analysis Femoral-Component-Analysis" in a two years follow-up (2.0-3.0 years). Migration patterns of unilateral and simultaneous cases were analysed and compared. RESULTS There was no difference between the two groups regarding age, body mass index and gender. After two years mean subsidence of all 202 implants was 1.43 mm (-6.5 mm to 2.0 mm). After initial subsidence of 0.37 mm per month within the first six weeks, the mean monthly migration was reduced to 0.02 mm between one and two years post-operative. There was no statistical difference in mean migration between unilateral (1.34 mm) and simultaneous bilateral (1.51 mm) THA (p = 0.33). CONCLUSION In summary, two years post-operative there was no difference in the amount of mean implant subsidence between unilateral compared to simultaneous bilateral short-stem THA. This suggests that regarding implant fixation simultaneous bilateral short-stem THA is as safe and successful as a solely unilateral intervention.
Collapse
|
41
|
Kutzner KP, Kovacevic MP, Freitag T, Fuchs A, Reichel H, Bieger R. Influence of patient-related characteristics on early migration in calcar-guided short-stem total hip arthroplasty: a 2-year migration analysis using EBRA-FCA. J Orthop Surg Res 2016; 11:29. [PMID: 26951069 PMCID: PMC4782512 DOI: 10.1186/s13018-016-0363-4] [Citation(s) in RCA: 28] [Impact Index Per Article: 3.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 01/15/2016] [Accepted: 03/03/2016] [Indexed: 12/15/2022] Open
Abstract
Background Short stems have gained popularity in recent years. Because of encouraging clinical results, indications have been expended from young to elderly and obese patients. However, long-term results are lacking. The purpose of this study was to evaluate the influence of gender, age, body weight, body mass index (BMI), and offset version on short-stem migration in correlation to the clinical outcome. Methods The implant migration of 202 metaphyseal-anchoring, calcar-guided short stems in 151 patients was assessed by “Einzel-Bild-Roentgen-Analyse” femoral component analysis (EBRA-FCA, femoral component analysis) in a 2-year follow-up. Full weight bearing was allowed directly after surgery. Patients were divided into groups regarding gender, age, body weight, BMI, and offset version. The Harris hip score (HHS) and satisfaction on visual analogue scale (VAS) were analyzed. Results After 2 years, mean axial subsidence of all 202 implants was 1.43 mm (standard deviation, SD 1.45 mm). A continuous reduction of initially pronounced subsidence over time could be observed. None of the stems had to be revised. Statistically significant increased rates of subsidence were seen in male (1.68 mm; SD 1.56 mm; p = 0.005) and heavy patients (1.54 mm; SD 1.48 mm; p = 0.022). No differences in implant migration were found regarding age, BMI, and different offset versions. HHS improved markedly from 45.8 (SD 15.9) to 98.1 (SD 4.7) while satisfaction on VAS improved from 1.8 (SD 2.2) to 9.7 (SD 0.9) after 2 years. Conclusions The results suggest a migration pattern with initially pronounced subsidence followed by subsequent stabilization. Male and obese patients show a slightly increased initial subsidence without any signs of sustained micromovement. No correlation was found concerning clinical results and pronounced initial subsidence above the threshold of 1.5 mm. No aseptic loosening or other signs of implant failure were seen within the observation period of 2 years. Trial registration German Clinical Trials Register, DRKS00009834.
Collapse
Affiliation(s)
- Karl Philipp Kutzner
- Department of Orthopaedic Surgery and Traumatology, St. Josefs Hospital Wiesbaden, Beethovenstr. 20, 65189, Wiesbaden, Germany.
| | - Mark Predrag Kovacevic
- Clinic of Traumatology, Hand- and Orthopaedic Surgery, HELIOS Dr. Horst Schmidt Clinic Wiesbaden, Ludwig-Erhard-Str. 100, 65199, Wiesbaden, Germany.
| | - Tobias Freitag
- Department of Orthopaedic Surgery, University of Ulm, Oberer Eselsberg 45, 89081, Ulm, Germany.
| | - Andreas Fuchs
- Department of Orthopaedic Surgery, University of Ulm, Oberer Eselsberg 45, 89081, Ulm, Germany.
| | - Heiko Reichel
- Department of Orthopaedic Surgery, University of Ulm, Oberer Eselsberg 45, 89081, Ulm, Germany.
| | - Ralf Bieger
- Department of Orthopaedic Surgery, University of Ulm, Oberer Eselsberg 45, 89081, Ulm, Germany.
| |
Collapse
|
42
|
Acklin YP, Jenni R, Bereiter H, Thalmann C, Stoffel K. Prospective clinical and radiostereometric analysis of the Fitmore short-stem total hip arthroplasty. Arch Orthop Trauma Surg 2016; 136:277-84. [PMID: 26739137 DOI: 10.1007/s00402-015-2401-9] [Citation(s) in RCA: 26] [Impact Index Per Article: 3.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 05/31/2015] [Indexed: 01/28/2023]
Abstract
INTRODUCTION Uncemented short, curved femoral stems may help save proximal bone stock during total hip arthroplasty (THA) and facilitate insertion in minimal invasive surgery. The aim of this 2 year, prospective, single-center study was to examine the stability and migration of the Fitmore (®) stem in THA using model-based radiostereometric analysis (RSA), and thus predict the implant's long-term survival. In addition, we evaluated the stem's clinical performance using standard clinical measures. PATIENTS AND METHODS We conducted a prospective cohort study of 34 THA patients who received the short Fitmore Hip Stem (Zimmer, Winterthur, Switzerland). At 3, 6, 12 and 24 months postoperatively, the patients underwent clinical evaluation and radiostereometric analysis (RSA) to measure stem migration. RESULTS RSA analysis revealed a mean subsidence of -0.39 mm (95 % CI -0.60 to -0.18) at 3 months with no further migration after 2 years. Mean internal rotation along the longitudinal axis was 1.09° (95 % CI 0.52-1.66) at 2 years, versus 0.85° (95 % CI 0.44-1.26) at 3 months. The Harris hip score improved from 60 (range 30-80) preoperatively to 99 (range 83-100) after 2 years. Three patients underwent revision due to deep infection, non-specific thigh pain and aseptic loosening in one case. CONCLUSION We conclude that the Fitmore Hip Stem stabilizes after 3 months and achieves good short-term clinical results in most cases.
Collapse
Affiliation(s)
- Yves P Acklin
- Orthopedic Surgery, Kantonsspital Graubünden, Loestrasse 99, 7000, Chur, Switzerland.
| | - Raphael Jenni
- Orthopedic Surgery, Kantonsspital Graubünden, Loestrasse 99, 7000, Chur, Switzerland
| | - Heinz Bereiter
- Orthopedic Surgery, Kantonsspital Graubünden, Loestrasse 99, 7000, Chur, Switzerland
| | - Caroline Thalmann
- Orthopedic Surgery, Kantonsspital Graubünden, Loestrasse 99, 7000, Chur, Switzerland
| | - Karl Stoffel
- Orthopedic Surgery, Kantonsspital Baselland, Rheinstrasse 26, Liestal, Switzerland
| |
Collapse
|
43
|
Scheerlinck T, Polfliet M, Deklerck R, Van Gompel G, Buls N, Vandemeulebroucke J. Development and validation of an automated and marker-free CT-based spatial analysis method (CTSA) for assessment of femoral hip implant migration: In vitro accuracy and precision comparable to that of radiostereometric analysis (RSA). Acta Orthop 2015; 87:139-45. [PMID: 26634843 PMCID: PMC4812075 DOI: 10.3109/17453674.2015.1123569] [Citation(s) in RCA: 15] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 01/31/2023] Open
Abstract
BACKGROUND AND PURPOSE We developed a marker-free automated CT-based spatial analysis (CTSA) method to detect stem-bone migration in consecutive CT datasets and assessed the accuracy and precision in vitro. Our aim was to demonstrate that in vitro accuracy and precision of CTSA is comparable to that of radiostereometric analysis (RSA). MATERIAL AND METHODS Stem and bone were segmented in 2 CT datasets and both were registered pairwise. The resulting rigid transformations were compared and transferred to an anatomically sound coordinate system, taking the stem as reference. This resulted in 3 translation parameters and 3 rotation parameters describing the relative amount of stem-bone displacement, and it allowed calculation of the point of maximal stem migration. Accuracy was evaluated in 39 comparisons by imposing known stem migration on a stem-bone model. Precision was estimated in 20 comparisons based on a zero-migration model, and in 5 patients without stem loosening. RESULTS Limits of the 95% tolerance intervals (TIs) for accuracy did not exceed 0.28 mm for translations and 0.20° for rotations (largest standard deviation of the signed error (SD(SE)): 0.081 mm and 0.057°). In vitro, limits of the 95% TI for precision in a clinically relevant setting (8 comparisons) were below 0.09 mm and 0.14° (largest SD(SE): 0.012 mm and 0.020°). In patients, the precision was lower, but acceptable, and dependent on CT scan resolution. INTERPRETATION CTSA allows detection of stem-bone migration with an accuracy and precision comparable to that of RSA. It could be valuable for evaluation of subtle stem loosening in clinical practice.
Collapse
|
44
|
[Accuracy of hip stem migration measurement on plain radiographs: reliability of bony and prosthetic landmarks]. DER ORTHOPADE 2015; 43:934-9. [PMID: 25223758 DOI: 10.1007/s00132-014-3014-7] [Citation(s) in RCA: 8] [Impact Index Per Article: 0.9] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 10/24/2022]
Abstract
BACKGROUND In Germany, more than 150,000 total hip arthroplasties (THA) are performed annually. Early implant migration is supposed to be the best indicator for mechanical failure of femoral stems. Therefore, radiological evaluation of hip stems is routinely done by analyzing plain radiographs of THA. OBJECTIVES The purpose of this study was to evaluate the accuracy of implant migration measurement on plain radiographs. MATERIAL AND METHODS Two observers analyzed 44 anterior-posterior radiographs of the pelvis in 22 pain-free patients at least 2 years after implantation of an anatomical hip stem. The evaluation was performed on digital as well as conventional plain radiographs. Intraobserver reliability was analyzed by double measurements of each radiograph and the evaluation of the consecutive series of each patient. The anatomical structures of interest were the greater trochanter and the minor trochanter. Furthermore, the tip of the prosthesis, the shoulder of the implant, and the center of rotation were determined. RESULTS The conventional measurement technique proved higher accuracy compared to the digital measurement technique. The best anatomical structure was the greater trochanter in the conventional technique and the minor trochanter in the digital technique. The best reference structure with regard to the implant was the shoulder of the prosthesis for both techniques. CONCLUSION The recommended reference structures for the evaluation of implant migration on plain radiographs are the greater trochanter and the shoulder of the implant for the conventional measurement technique and the minor trochanter and the shoulder of the implant for the digital technique. Migration of an implant should not assumed before a determined difference of 2 mm.
Collapse
|
45
|
Budde S, Seehaus F, Schwarze M, Hurschler C, Floerkemeier T, Windhagen H, Noll Y, Ettinger M, Thorey F. Analysis of migration of the Nanos® short-stem hip implant within two years after surgery. INTERNATIONAL ORTHOPAEDICS 2015; 40:1607-1614. [PMID: 26404094 DOI: 10.1007/s00264-015-2999-9] [Citation(s) in RCA: 30] [Impact Index Per Article: 3.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 07/05/2015] [Accepted: 09/14/2015] [Indexed: 02/07/2023]
Abstract
PURPOSE Short-stem implants provide a bone-preserving alternative in total hip arthroplasty. However, some evidence exists that the smaller implant-bone contact surface may compromise primary stability and impair osseo-integration. The purpose of this study was to analyse the migration characteristics of the Nanos® short stem over two years by means of model-based roentgen stereophotogrammetric analysis (MBRSA). METHODS Eighteen patients aged 53.6 ± 7.2 years were included. After being treated with a Nanos implant, 14 patients were followed-up radiologically at three, six, 12 and 24 months by means of MBRSA. Early implant migration was calculated. Clinical data have been assessed in addition. RESULTS Highest translational migration was observed with a mean value of -0.22 ± 0.39 mm along the proximo-distal axis after three months and highest rotational migration with 0.8 ± 3.2° also around the y-axis after two years. The resulting total migration was 0.46 ± 0.31 mm, with the largest proportion occurring within three months after surgery (0.40 ± 0.34 mm). CONCLUSION The Nanos short-stem hip implant shows only a slight initial migration within three months after implantation, followed by secondary stabilisation. These results suggest both good primary stability and osseo-integration, suggesting a low risk of aseptic loosening.
Collapse
Affiliation(s)
- Stefan Budde
- Department of Orthopaedic Surgery, Hannover Medical School, Anna-von-Borries-Str. 1-7, 30625, Hannover, Germany.
| | - Frank Seehaus
- Laboratory for Biomechanics and Biomaterials, Department of Orthopaedic Surgery, Hannover Medical School, Anna-von-Borries-Str. 1-7, 30625, Hannover, Germany
| | - Michael Schwarze
- Laboratory for Biomechanics and Biomaterials, Department of Orthopaedic Surgery, Hannover Medical School, Anna-von-Borries-Str. 1-7, 30625, Hannover, Germany
| | - Christof Hurschler
- Laboratory for Biomechanics and Biomaterials, Department of Orthopaedic Surgery, Hannover Medical School, Anna-von-Borries-Str. 1-7, 30625, Hannover, Germany
| | - Thilo Floerkemeier
- Department of Orthopaedic Surgery, Hannover Medical School, Anna-von-Borries-Str. 1-7, 30625, Hannover, Germany
| | - Henning Windhagen
- Department of Orthopaedic Surgery, Hannover Medical School, Anna-von-Borries-Str. 1-7, 30625, Hannover, Germany
| | - Yvonne Noll
- Department of Orthopaedic Surgery, Hannover Medical School, Anna-von-Borries-Str. 1-7, 30625, Hannover, Germany
| | - Max Ettinger
- Department of Orthopaedic Surgery, Hannover Medical School, Anna-von-Borries-Str. 1-7, 30625, Hannover, Germany
| | - Fritz Thorey
- Centre for Hip, Knee and Foot Surgery, Sports Traumatology, ATOS Hospital, Bismarckstr. 9-15, 69115, Heidelberg, Germany
| |
Collapse
|
46
|
Tandara AA, Capeller LJ, Jarczok MN, Mayrhofer P, Jung M, Daecke W. A software tool for prediction of prosthesis failure at the carpometacarpal joint of the thumb. J Hand Surg Eur Vol 2015; 40:364-9. [PMID: 25190607 DOI: 10.1177/1753193414548644] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 01/20/2013] [Accepted: 12/16/2013] [Indexed: 02/03/2023]
Abstract
Early recognition of prosthesis failure is difficult. A tool that helps to identify faulty prosthesis - a cause of early implant loosening - is needed. The aim of this study was to detect early implant loosening by applying a software program EBRA (Ein-Bild-Röntgen-Analyse). EBRA was applied to the radiographs of a series of 76 patients, with a total of 102 thumb carpometacarpal joint de la Caffinière prostheses, with an average follow-up of 14.5 months (range 0.5-24). The data were used to draw graphs of cup migration and inclination over time. Corresponding regression lines of migration and inclination in relation to time were made up to the point of loosening. The gradient of regression was calculated for all implants. The gradient of regression on the x and y axes differed significantly between stable and loose implants. Loose and stable implants showed significantly different cup migration on the x and y axes over time. EBRA proved to be a reliable tool to visualize cup migration in the trapeziometacarpal joint and to predict implant failure.
Collapse
Affiliation(s)
- A A Tandara
- Department of Surgery, Heidelberg University Hospital, Heidelberg, Germany
| | - L J Capeller
- Surgical Outpatient-Clinic Wiesloch, Wiesloch, Germany
| | - M N Jarczok
- Mannheim Institute of Public Health, Social and Preventive Medicine, Heidelberg University, Mannheim, Germany
| | - P Mayrhofer
- Geometry and CAD, Leopold-Franzens-University Innsbruck, Innsbruck, Austria
| | | | - W Daecke
- Frankfurt Höchst Clinic, Frankfurt, Germany
| |
Collapse
|
47
|
Migration characteristics and early clinical results of the NANOS® short-stem hip arthroplasty. Wien Klin Wochenschr 2015; 127:375-8. [DOI: 10.1007/s00508-015-0756-0] [Citation(s) in RCA: 13] [Impact Index Per Article: 1.4] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/19/2014] [Accepted: 01/21/2015] [Indexed: 02/06/2023]
|
48
|
Migration pattern of a femoral short-stem prosthesis: a 2-year EBRA-FCA-study. Arch Orthop Trauma Surg 2014; 134:1003-8. [PMID: 24691814 DOI: 10.1007/s00402-014-1984-x] [Citation(s) in RCA: 27] [Impact Index Per Article: 2.7] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 10/23/2013] [Indexed: 12/18/2022]
Abstract
INTRODUCTION Short-stem prostheses enable bone stock preserving total hip arthroplasty. However, little is known about the durability of this group of implants. The most common cause for implant failure is aseptic loosening. Early implant migration is supposed to be the best indicator for mechanical failure of femoral stems. The purpose of this study was to evaluate the migration pattern of a short stem implant and the influence of BMI, gender and femoral offset on implant migration. MATERIALS AND METHODS After a minimum follow-up of 2 years, 72 hips were included in this EBRA-FCA-study. The mean age at surgery of the 34 female and 32 male patients was 54 years (range 22-75 years). The mean BMI was 29 kg/m(2) (range 21-51 kg/m(2)). RESULTS Mean axial subsidence was 1 mm (±1.4 mm) after 24 months. BMI, gender and implant offset did not influence implant migration on a statistical significant level. Nevertheless, a tendency towards more migration in obese and female patients was observed. CONCLUSION The evaluated short stem prosthesis showed a migration pattern similar to clinical proven standard straight stem implants. The indication of short-stem prostheses should be critically evaluated in obese and female patients.
Collapse
|
49
|
Loosely implanted cementless stems may become rotationally stable after loading. Clin Orthop Relat Res 2014; 472:2231-6. [PMID: 24664196 PMCID: PMC4048396 DOI: 10.1007/s11999-014-3577-y] [Citation(s) in RCA: 10] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 10/22/2013] [Accepted: 03/22/2014] [Indexed: 01/31/2023]
Abstract
BACKGROUND Experimental studies have suggested that initial micromotion of cementless components may lead to failure of osteointegration. Roentgen stereophotogrammetric analyses have shown durable implant fixation can be achieved long-term even when initial instability exists, as evidenced by subsidence. However improved implant stability as a result of subsidence, before osteointegration, has not been shown biomechanically. QUESTIONS/PURPOSES We asked whether insertionally loose cementless tapered femoral stems show (1) less rotational stability (more toggle); (2) more subsidence; and (3) reduced ability to resist torsion (lower initial construct stiffness), lower torque at failure, and greater rotation to failure in comparison to well-fixed cementless tapered femoral stems. METHODS Ten matched pairs of cadaveric femurs were implanted with well-fixed and loose cementless tapered stems. The loose stem construct was obtained by appropriately broaching the femur but afterwards inserting a stem one size smaller than that broached. Femoral stem rotational stability of implanted femurs was tested by measuring the angular rotation (ie, toggle) required to produce a torque of 2 N-m at 0 N, 250 N, and 500 N vertical load in 25° adduction simulating single-legged stance. Subsidence was measured as vertical movement during the toggle tests. Then at 500 N initial vertical load, femoral stems were externally rotated to failure. The construct stiffness between 5 and 40 N-m was determined to assess ability to resist torsion. The torque and rotation to failure were recorded to compare failure characteristics. Groups were compared using mixed model ANOVA followed by Tukey-Kramer post hoc pairwise comparison for toggle and subsidence tests and by Student's paired t-tests for stiffness, torque at failure, and rotation to failure tests. RESULTS Loose tapered cementless stems were less stable (ie, more toggle) than well-fixed at 0 N of load (p < 0.0001), but no difference was detectable in toggle between loose and well-fixed stems at 250 N (p = 0.7019) and 500 N (p = 0.9970). Loose tapered cementless stems showed significant subsidence at 250 N (p < 0.0001) and 500 N (p < 0.0001), which was not found in the well-fixed stems at 250 N (p = 0.8813) and 500 N (p = 0.1621). Torsional stiffness was lower for loose stems as compared with well-fixed stems (p = 0.0033). No difference in torque at failure (p = 0.7568) or rotation to failure (p = 0.2629) was detected between loose and well-fixed stems. CONCLUSIONS In this study, we observed that insertionally loose cementless stems have the ability to subside and become rotationally stable with loading. They did not exhibit a lower torque or rotation to failure in comparison to well-fixed stems when under simulated single-legged stance. CLINICAL RELEVANCE Secondary rotational stabilization may prevent insertionally loose tapered stems from producing a stress pattern that predisposes to early postoperative periprosthetic fracture around loose cemented stems.
Collapse
|
50
|
Prospective five-year subsidence analysis of a cementless fully hydroxyapatite-coated femoral hip arthroplasty component. Hip Int 2014; 24:91-7. [PMID: 24474406 PMCID: PMC6159840 DOI: 10.5301/hipint.5000082] [Citation(s) in RCA: 12] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Accepted: 06/28/2013] [Indexed: 02/04/2023]
Abstract
Early subsidence >1.5 mm is considered to be a predictive factor for later aseptic loosening of the femoral component following total hip arthroplasty (THA). The aim of this study was to assess five-year subsidence rates of the cementless hydroxyapatite-coated twinSys stem (Mathys Ltd., Bettlach, Switzerland).This prospective single-surgeon series examined consecutive patients receiving a twinSys stem at Maria Middelares Hospital, Belgium. Patients aged >85 years or unable to come to follow-up were excluded. Subsidence was assessed using Ein Bild Roentgen Analyse--Femoral Component Analysis (EBRA-FCA). Additional clinical and radiographic assessments were performed. Follow-ups were prospectively scheduled at two, five, 12, 24, and 60 months.In total, 218 THA (211 patients) were included. At five years, mean subsidence was 0.66 mm (95% CI: 0.43-0.90). Of the 211 patients, 95.2% had an excellent or good Harris Hip Score. There were few radiological changes. Kaplan-Meier analysis indicated five-year stem survival to be 98.4% (95% CI: 97.6-100%).Subsidence levels of the twinSys femoral stem throughout the five years of follow-up were substantially lower than the 1.5 mm level predictive of aseptic loosening. This was reflected in the high five-year survival rate.
Collapse
|