1
|
Koutserimpas C, Karaiskos I, Piagkou M. The Insertion of Threaded Acetabulum Components: Indications According to Specific Acetabulum Anatomy and Methods to Avoid Pitfalls. Cureus 2023; 15:e50824. [PMID: 38249265 PMCID: PMC10799201 DOI: 10.7759/cureus.50824] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Accepted: 12/19/2023] [Indexed: 01/23/2024] Open
Abstract
New-generation threaded acetabulum components have been used in total hip arthroplasty (THA) with good outcomes. We have extensively used the EcoFit® SC cup (Implantcast, Buxtehude, Germany) in our practice. In this report, we present some major complications related to the use of this implant, as well as insights regarding the surgical technique to avoid such adverse effects. Furthermore, we attempt to describe certain contraindications for using threaded cups in THA, taking into account specific patient anatomy and intraoperative acetabulum preparation. We have observed acetabulum roof and posterior wall fractures, as well as incomplete placement of the component. Ensuring the meticulous preparation of the peripheral rim of the acetabulum is crucial to prevent incomplete placement since threaded components have a larger diameter than that of the reamers used to prepare the acetabulum. Additionally, when dealing with the acetabula where the posterior or anterior walls have thinned, it is advisable to refrain from using a threaded cup to avoid the risk of intraoperative fractures caused by the torque forces exerted during implant insertion.
Collapse
Affiliation(s)
- Christos Koutserimpas
- Department of Orthopaedics and Traumatology, "251" Hellenic Air Force General Hospital, Athens, GRC
| | - Ilias Karaiskos
- Department of Orthopaedics and Traumatology, "251" Hellenic Air Force General Hospital, Athens, GRC
| | - Maria Piagkou
- Anatomy/Oral Surgery, National and Kapodistrian University of Athens, Athens, GRC
| |
Collapse
|
2
|
Tottas S, Ververidis A, Kougioumtzis I, Tilkeridis K, Tsigalou C, Karaglani M, Drosos G. MINIMA Short Stem Versus Standard Profemur (TL) Stem in Primary Total Hip Replacement: A Comparative Study. Cureus 2022; 14:e23771. [PMID: 35509762 PMCID: PMC9062282 DOI: 10.7759/cureus.23771] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Accepted: 04/02/2022] [Indexed: 12/28/2022] Open
Abstract
Background: The objective of our study was to compare a novel squared section, tapered design - with four conicity - short stem, the MINIMA® short stem with the cementless Profemur® TL standard femoral stem in primary total hip arthroplasty (THA) in terms of functional outcomes, radiologic evaluation and other peri-operative and post-operative data. Material and methods: This is a comparative study including 46 patients undergoing primary THA. In 23 patients, the MINIMA® short stem was used. These patients were matched with another 23 patients in whom a cementless Profemur® TL standard femoral stem was used. The levels of the pain were evaluated according to the Visual Analog Scale/Numerical Rating Scale (VAS/NRS). The functional and clinical evaluation of the patients was performed with Harris Hip Score (HHS), Charnley’s Hip score, EuroQol (EQ-5D)-(EQ-100), Patient Health Questionnaire (PHQ-9), and neuropathic pain questionnaire (DN-4). The rest of the comparison data included demographic data, the American Society of Anesthesiologists score (ASA), Charlson Index score, the pre-operative diagnosis, radiographic evaluation, the days of hospitalization, the operating time, incision length, blood loss, and blood transfusion requirements and complication rates. Results: The two cohorts had comparable results regarding all patients’ peri-operative data. The radiographic assessment revealed considerable higher levels of femoral offset and femoral subsidence for the MINIMA group, but within acceptable limits for both cohorts. The majority of the functional and other scores did not give strong prominence to one specific femoral stem. Conclusion: Our comparative study underlined the efficacy of the MINIMA® short stem, due to the fact that it revealed comparable and, in some cases, relatively better short-term outcomes compared with the TL standard femoral stem. Yet, more well-designed long-term research is required in order to further establish its effectiveness.
Collapse
Affiliation(s)
- Stylianos Tottas
- Orthopeadics, University General Hospital of Alexandroupolis/Democritus University of Thrace, Alexandroupolis, GRC
| | - Athanasios Ververidis
- Orthopeadics, University General Hospital of Alexandroupolis/Democritus University of Thrace, Alexandroupolis, GRC
| | - Ioannis Kougioumtzis
- Orthopeadics, University General Hospital of Alexandroupolis/Democritus University of Thrace, Alexandroupolis, GRC
| | - Konstantinos Tilkeridis
- Orthopeadics, University General Hospital of Alexandroupolis/Democritus University of Thrace, Alexandroupolis, GRC
| | - Christina Tsigalou
- Medical-Molecular Microbiology, University General Hospital of Alexandroupolis/Democritus University of Thrace, Alexandroupolis, GRC
| | - Makrina Karaglani
- Laboratory of Pharmacology, Medical School/Democritus University of Thrace, Alexandroupolis, GRC
| | - Georgios Drosos
- Orthopeadics, University General Hosital of Alexandroupolis/Democritus University of Thrace, Alexandroupolis, GRC
| |
Collapse
|
3
|
Nicolli A, Trevisan A, Bortoletti I, Pozzuoli A, Ruggieri P, Martinelli A, Gambalunga A, Carrieri M. Biological Monitoring of Metal Ions Released from Hip Prostheses. Int J Environ Res Public Health 2020; 17:E3223. [PMID: 32384733 DOI: 10.3390/ijerph17093223] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [What about the content of this article? (0)] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 02/28/2020] [Revised: 04/24/2020] [Accepted: 05/04/2020] [Indexed: 01/06/2023]
Abstract
The aim of this study was to evaluate the levels of As, Be, Bi, Cd, Co, Cr, Cu, Hg, Mn, Ni, Pb, Se, Tl, V, and Zn, by inductively coupled plasma-mass spectrometry (ICP-MS) in the urine of two groups of patients with two different types of metal-on-metal (MoM) total hip prostheses (ASR DePuy®, group A, 25 patients; total Met-Met System Lima®, group B, 28 patients). The determination of metals reflected a steady-state release (group A: 9 years after surgery and group B: 6 years after surgery). The results obtained confirmed the increase of Co and Cr urinary levels in both group when compared with the reference values for the general population adopted by the Italian Society of Reference Values (SIVR). In particular, Co and Cr levels exceeded the threshold values in urine, respectively, of 30 μg and 21 µg, adjusted to creatinine based on the threshold in whole blood of 7 μg/L proposed by the Medicines and Healthcare Products Regulatory Agency (MHRA). Regarding the other investigated metals, significantly higher values were found in Group A than in Group B. These differences could be due to the type of hip prosthesis implanted, the longer period of time since the implantation, as well as many other factors such as diet, age, drug consumption, physical activity, or presence of dental fillings. The continuous monitoring over the years of metal concentrations in patients carrying a prosthesis could be useful to better identify the sources of these metals.
Collapse
|
4
|
Gargiulo P, Edmunds KJ, Gíslason MK, Latour C, Hermannsson Þ, Esposito L, Bifulco P, Cesarelli M, Fraldi M, Cristofolini L, Jónsson H. Patient-specific mobility assessment to monitor recovery after total hip arthroplasty. Proc Inst Mech Eng H 2018; 232:1048-1059. [PMID: 30191747 DOI: 10.1177/0954411918797971] [Citation(s) in RCA: 8] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/22/2022]
Abstract
Total hip arthroplasty is a ubiquitously successful orthopedic surgical procedure, whose prevalence is rising worldwide. While many investigations focus on characterizing periprosthetic pathophysiology, the objective of our research is to develop and describe multi-metric assemblies as a first step toward creating a patient-specific mobility index that rehabilitators and orthopedic surgeons can utilize for prescribing their respective procedures. In total, 48 total hip arthroplasty patients (both cemented and uncemented) undergoing unilateral, primary surgery went through computed tomographic scans and gait analysis measurements both before and 1 year following their surgery. Altogether, the reported quantitative metrics include 11 spatial and temporal gait parameters, muscle density, and electromyography signals from the rectus femoris, vastus lateralis, and vastus medialis, and bone mineral density values from bioimage analysis around the implant stem. We found that measured parameters from a subgroup were sensitive to changes observed during patient recovery, implicating the predictive sensitivity of these patient conditions. Most post-operative gait parameters changed significantly, while electromyography data indicated few significant differences. Moreover, results from bioimage analyses indicate a general reduction of periprosthetic bone mineral density after 1 year, in association with increasing density of the quadriceps muscles. Furthermore, this work identifies which quantitative metrics undergo the greatest variation after total hip arthroplasty and demonstrates the clinical feasibility of a multimodal approach to mobility assessment that may ultimately support decision-making for post-surgical rehabilitation protocols.
Collapse
Affiliation(s)
- Paolo Gargiulo
- 1 Institute for Biomedical and Neural Engineering, Reykjavík University, Reykjavík, Iceland.,2 Department of Science, Landspítali University Hospital, Reykjavík, Iceland
| | - Kyle Joseph Edmunds
- 1 Institute for Biomedical and Neural Engineering, Reykjavík University, Reykjavík, Iceland
| | - Magnús K Gíslason
- 1 Institute for Biomedical and Neural Engineering, Reykjavík University, Reykjavík, Iceland
| | - Chase Latour
- 3 Washington University in St. Louis, St. Louis, MO, USA
| | - Þröstur Hermannsson
- 1 Institute for Biomedical and Neural Engineering, Reykjavík University, Reykjavík, Iceland
| | - Luca Esposito
- 4 Department of Structures for Engineering and Architecture, University of Naples Federico II, Naples, Italy
| | - Paolo Bifulco
- 5 Department of Electrical Engineering and Information Technologies, University of Naples Federico II, Naples, Italy
| | - Mario Cesarelli
- 5 Department of Electrical Engineering and Information Technologies, University of Naples Federico II, Naples, Italy
| | - Massimiliano Fraldi
- 4 Department of Structures for Engineering and Architecture, University of Naples Federico II, Naples, Italy.,6 Interdisciplinary Research Centre for Biomaterials, University of Naples Federico II, Naples, Italy
| | - Luca Cristofolini
- 7 Department of Industrial Engineering, University of Bologna, Bologna, Italy
| | - Halldór Jónsson
- 8 Faculty of Medicine, University of Iceland, Reykjavík, Iceland.,9 Orthopedic Clinic, Landspítali University Hospital, Reykjavík, Iceland
| |
Collapse
|
5
|
Mahuvava C, Du Plessis FCP. Dosimetry Effects Caused by Unilateral and Bilateral Hip Prostheses: A Monte Carlo Case Study in Megavoltage Photon Radiotherapy for Computed Tomography Data without Metal Artifacts. J Med Phys 2018; 43:236-246. [PMID: 30636849 PMCID: PMC6299754 DOI: 10.4103/jmp.jmp_70_18] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/27/2022] Open
Abstract
Background: Hip prostheses (HPs) are routinely used in hip augmentation to replace painful or dysfunctional hip joints. However, high-density and high-atomic-number (Z) inserts may cause dose perturbations in the target volume and interface regions. Aim: To evaluate the dosimetric influence of various HPs during megavoltage conformal radiotherapy (RT) of the prostate using Monte Carlo (MC) simulations. Materials and Methods: BEAMnrc and DOSXYZnrc MC user-codes were respectively used to simulate the linac head and to calculate 3D absorbed dose distributions in a computed tomography (CT)-based phantom. A novel technique was used to synthetically introduce HPs into the raw patient CT dataset. The prosthesis materials evaluated were stainless steel (SS316L), titanium (Ti6Al4V), and ultra-high-molecular-weight polyethylene (UHMWPE). Four, five, and six conformal photon fields of 6–20 MV were used. Results: The absorbed dose within and beyond metallic prostheses dropped significantly due to beam attenuation. For bilateral HPs, the target dose reduction ranged up to 23% and 17% for SS316L and Ti6Al4V, respectively. For unilateral HP, the respective dose reductions were 19% and 12%. Dose enhancement was always <1% for UHMWPE. The 6-field plan produced the best target coverage. Up to 38% dose increase was found at the bone–SS316L proximal interface. Conclusions: The novel technique used enabled the complete exclusion of metal artifacts in the CT dataset. High-energy plans with more oblique beams can help minimize dose attenuation through HPs. Shadowing and interface effects are density dependent and greatest for SS316L, while UHMWPE poses negligible dose perturbation.
Collapse
Affiliation(s)
- Courage Mahuvava
- Department of Medical Physics, Faculty of Health Sciences, University of the Free State, Bloemfontein, South Africa
| | | |
Collapse
|
6
|
Bills P, Racasan R, Bhattacharya S, Blunt L, Isaac G. Comparative study of material loss at the taper interface in retrieved metal-on-polyethylene and metal-on-metal femoral components from a single manufacturer. Proc Inst Mech Eng H 2017; 231:683-690. [PMID: 28393608 DOI: 10.1177/0954411917701496] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/27/2022]
Abstract
There have been a number of reports on the occurrence of taper corrosion and/or fretting and some have speculated on a link to the occurrence of adverse local tissue reaction specifically in relation to total hip replacement which have a metal-on-metal bearing. As such a study was carried out to compare the magnitude of material loss at the taper in a series of retrieved femoral heads used in metal-on-polyethylene bearings with that in a series of retrieved heads used in metal-on-metal bearings. A total of 36 metal-on-polyethylene and 21 metal-on-metal femoral components were included in the study all of which were received from a customer complaint database. Furthermore, a total of nine as-manufactured femoral components were included to provide a baseline for characterisation. All taper surfaces were assessed using an established corrosion scoring method and measurements were taken of the female taper surface using a contact profilometry. In the case of metal-on-metal components, the bearing wear was also assessed using coordinate metrology to determine whether or not there was a relationship between bearing and taper material loss in these cases. The study found that in this cohort the median value of metal-on-polyethylene taper loss was 1.25 mm3 with the consequent median value for metal-on-metal taper loss being 1.75 mm3. This study also suggests that manufacturing form can result in an apparent loss of material from the taper surface determined to have a median value of 0.59 mm3. Therefore, it is clear that form variability is a significant confounding factor in the measurement of material loss from the tapers of femoral heads retrieved following revision surgery.
Collapse
Affiliation(s)
- Paul Bills
- 1 Centre for Precision Technologies, University of Huddersfield, Huddersfield, UK
| | - Radu Racasan
- 1 Centre for Precision Technologies, University of Huddersfield, Huddersfield, UK
| | | | - Liam Blunt
- 1 Centre for Precision Technologies, University of Huddersfield, Huddersfield, UK
| | - Graham Isaac
- 2 DePuy Synthes, Leeds, UK.,3 Institute of Medical and Biological Engineering, University of Leeds, Leeds, UK
| |
Collapse
|
7
|
Dold P, Pandorf T, Flohr M, Preuss R, Bone MC, Joyce TJ, Holland J, Deehan D. Acetabular shell deformation as a function of shell stiffness and bone strength. Proc Inst Mech Eng H 2016; 230:259-64. [PMID: 26888887 DOI: 10.1177/0954411916632792] [Citation(s) in RCA: 8] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/09/2015] [Accepted: 12/21/2015] [Indexed: 11/16/2022]
Abstract
Press-fit acetabular shells used for hip replacement rely upon an interference fit with the bone to provide initial stability. This process may result in deformation of the shell. This study aimed to model shell deformation as a process of shell stiffness and bone strength. A cohort of 32 shells with two different wall thicknesses (3 and 4 mm) and 10 different shell sizes (44- to 62-mm outer diameter) were implanted into eight cadavers. Shell deformation was then measured in the cadavers using a previously validated ATOS Triple Scan III optical system. The shell-bone interface was then considered as a spring system according to Hooke's law and from this the force exerted on the shell by the bone was calculated using a combined stiffness consisting of the measured shell stiffness and a calculated bone stiffness. The median radial stiffness for the 3-mm wall thickness was 4192 N/mm (range, 2920-6257 N/mm), while for the 4-mm wall thickness the median was 9633 N/mm (range, 6875-14,341 N/mm). The median deformation was 48 µm (range, 3-187 µm), while the median force was 256 N (range, 26-916 N). No statistically significant correlation was found between shell stiffness and deformation. Deformation was also found to be not fully symmetric (centres 180° apart), with a median angle discrepancy of 11.5° between the two maximum positive points of deformation. Further work is still required to understand how the bone influences acetabular shell deformation.
Collapse
Affiliation(s)
- Philipp Dold
- Medical Products Division, CeramTec GmbH, Plochingen, Germany
| | - Thomas Pandorf
- Medical Products Division, CeramTec GmbH, Plochingen, Germany
| | - Markus Flohr
- Medical Products Division, CeramTec GmbH, Plochingen, Germany
| | - Roman Preuss
- Medical Products Division, CeramTec GmbH, Plochingen, Germany
| | - Martin C Bone
- School of Mechanical Engineering, Newcastle University, Newcastle upon Tyne, UK
| | - Tom J Joyce
- School of Mechanical Engineering, Newcastle University, Newcastle upon Tyne, UK
| | - James Holland
- Newcastle Surgical Training Centre, Freeman Hospital, Newcastle upon Tyne, UK
| | - David Deehan
- Newcastle Surgical Training Centre, Freeman Hospital, Newcastle upon Tyne, UK
| |
Collapse
|
8
|
Grosse S, Haugland HK, Lilleng P, Ellison P, Hallan G, Høl PJ. Wear particles and ions from cemented and uncemented titanium-based hip prostheses-a histological and chemical analysis of retrieval material. J Biomed Mater Res B Appl Biomater 2014; 103:709-17. [PMID: 25051953 PMCID: PMC4413358 DOI: 10.1002/jbm.b.33243] [Citation(s) in RCA: 44] [Impact Index Per Article: 4.4] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/05/2014] [Revised: 06/10/2014] [Accepted: 07/08/2014] [Indexed: 12/13/2022]
Abstract
Wear debris-induced inflammation is considered to be the main cause for periprosthetic osteolysis in total hip replacements (THR). The objective of this retrieval study was to examine the tissue reactions and exposure to metal ions and wear particles in periprosthetic tissues and blood samples from patients with titanium (Ti)-based hip prostheses that were revised due to wear, osteolysis, and/or aseptic loosening. Semiquantitative, histological tissue evaluations in 30 THR-patients revealed numerous wear debris-loaded macrophages, inflammatory cells, and necrosis in both groups. Particle load was highest in tissues adjacent to loosened cemented Ti stems that contained mainly submicron zirconium (Zr) dioxide particles. Particles containing pure Ti and Ti alloy elements were most abundant in tissues near retrieved uncemented cups. Polyethylene particles were also detected, but accounted only for a small portion of the total particle number. The blood concentrations of Ti and Zr were highly elevated in cases with high abrasive wear and osteolysis. Our findings indicate that wear particles of different chemical composition induced similar inflammatory responses, which suggests that particle size and load might be more important than the wear particle composition in periprosthetic inflammation and osteolysis. © 2014 The Authors. Journal of Biomedical Materials Research Part B: Applied Biomaterials Published by Wiley Periodicals, Inc. J Biomed Mater Res Part B: Appl Biomater, 103B:709–717, 2015.
Collapse
Affiliation(s)
- Susann Grosse
- Department of Clinical Medicine, University of Bergen, N-5021, Norway
| | | | | | | | | | | |
Collapse
|
9
|
Herrera A, Rebollo S, Ibarz E, Mateo J, Gabarre S, Gracia L. Mid-term study of bone remodeling after femoral cemented stem implantation: comparison between DXA and finite element simulation. J Arthroplasty 2014; 29:90-100. [PMID: 23725926 DOI: 10.1016/j.arth.2013.03.028] [Citation(s) in RCA: 15] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 01/24/2013] [Revised: 03/21/2013] [Accepted: 03/23/2013] [Indexed: 02/01/2023] Open
Abstract
This five-year prospective study was designed to investigate periprosthetic bone remodeling associated with two cemented stem models, ABG-II (Stryker) and VerSys (Zimmer), randomly implanted in patients older than 75 years. The sample consisted of 64 cases (32, ABG-II; 32, VerSys). Inclusion criterion was diagnosis of osteoarthritis recommended for cemented total hip arthroplasty. Besides clinical study, Finite Element (FE) simulation was used to analyze biomechanical changes caused by hip arthroplasty. Bone Mineral Density (BMD) measurements showed a progressive increase in bone mass throughout the entire follow-up period for both stems, well correlated with FE results except in Gruen zones 4, 5, 6 for ABG-II and in zones 4, 5 for VerSys, denoting that remodeling in those zones does not depend on mechanical factors but rather on biological or physiological ones.
Collapse
Affiliation(s)
- Antonio Herrera
- Department of Orthopaedic and Trauma Surgery, Miguel Servet University Hospital, Medicine School, University of Zaragoza, Zaragoza, Spain; Orthopaedic Surgery, Miguel Servet University Hospital, Zaragoza, Spain
| | | | | | | | | | | |
Collapse
|