Hollensteiner M, Sandriesser S, Augat P. Open the pores - Polydimethylsiloxane influences the porous structure of cancellous bone surrogates for biomechanical testing of osteosyntheses. J Biomech 2024; 165:112000. [PMID: 38387369 DOI: 10.1016/j.jbiomech.2024.112000] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/20/2023] [Revised: 02/08/2024] [Accepted: 02/14/2024] [Indexed: 02/24/2024]
Abstract
Synthetic materials used for valid and reliable implant testing and design should reflect the mechanical and morphometric properties of human bone. Such bone models are already available on the market, but they do not reflect the population variability of human bone, nor are they open-celled porous as human bone is. Biomechanical studies aimed at cementing the fracture or an implant cannot be conducted with them. The aim of this study was to investigate the influence of a cell stabilizer on polyurethane-based cancellous synthetic bone in terms of morphology, compressive mechanics, and opening of the cancellous bone structure for bone cement application. Mechanical properties of cylindrical specimens of the bone surrogates were determined by static compression tests to failure. Furthermore, a morphometric analysis was performed using microcomputed tomography. To prove the open-cell nature of the bone surrogates, an attempt was made to apply bone cement. Effects on the mechanical properties of the polyurethane-based bone surrogates were observed by the addition of polydimethylsiloxane. All mechanical parameters like Young's modulus, ultimate stress and yield stress increased statistically significantly with increasing amounts of cell stabilizer (all p > 0.001), except for yield stress. The analysis of morphometric parameters showed a decrease in trabecular thickness, spacing and connectivity density, which was accompanied by an increase in trabecular number and an increase in pore size. The open-cell nature was proven by the application and distribution of bone cement in specimens with stabilizer, which was visualized by X-ray. In conclusion, the results show that by adding a cell stabilizer, polyurethane-based cancellous bone substrates can be produced that have an open-cell structure similar to human bone. This makes these bone surrogates suitable for biomechanical testing of osteosyntheses and for osteosynthesis cementation issues.
Collapse
Affiliation(s)
- Marianne Hollensteiner
- Institute for Biomechanics, BG Unfallklinik Murnau, Prof.-Küntscher-Straße 8, 82418 Murnau, Germany; Institute for Biomechanics, Paracelsus Medical University Salzburg, Strubergasse 21, 5020 Salzburg, Austria.
| | - Sabrina Sandriesser
- Institute for Biomechanics, BG Unfallklinik Murnau, Prof.-Küntscher-Straße 8, 82418 Murnau, Germany; Institute for Biomechanics, Paracelsus Medical University Salzburg, Strubergasse 21, 5020 Salzburg, Austria
| | - Peter Augat
- Institute for Biomechanics, BG Unfallklinik Murnau, Prof.-Küntscher-Straße 8, 82418 Murnau, Germany; Institute for Biomechanics, Paracelsus Medical University Salzburg, Strubergasse 21, 5020 Salzburg, Austria
| |
Collapse
|
2
|
Tavares MCMS, Silveira RMF, Arno A, de Lara IAR, Salvador ML, de Freitas SM, da Silva IJO. Environmental enrichment in finishing pigs: does it promote any changes in bone biomechanics? Trop Anim Health Prod 2023; 55:408. [PMID: 37987872 DOI: 10.1007/s11250-023-03830-x] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/27/2023] [Accepted: 11/07/2023] [Indexed: 11/22/2023]
Abstract
The resistance of pigs' bone structure was evaluated for the first time, reared with and without environmental enrichment (EE) in the finishing phase using techniques in bone biomechanics; 432 swine from the Hampshire breed, being males and females, with initial body weight between 22 and 27 kg and final body weight between 110 and 125 kg were evaluated for 112 days. The experimental design was in randomized blocks, with 6 treatments, distributed in a 2 × 3 factorial scheme (sex × conditions in creation), with 12 repetitions/treatment, totaling 72 pens. The treatments were as follows: branched chain for males (T1), sisal branched string for males (T2), males without EE (T3), branched chain for females (T4), sisal branched string for females (T5), and females without EE (T6). At the end of the experimental period, all animals were slaughtered in an industrial slaughterhouse, having their femur bones collected for bone biomechanics analysis. There was no effect (P > 0.05) of the interaction (enrichment × sex) and individual factors for bone weight. There was a tendency (P = 0.08) of the interaction for flexion force, being higher in males enriched with branched ropes and chains. For breaking stress, there was an interaction effect (P = 0.04), being the females without EE the ones showing the lowest breaking stress, favoring bone fragility. The use of branched ropes and chains strengthens the bone structure in swine in the termination phase (110-125 kg BW - 183-190 days in age), being an important strategy used to meet the animal welfare requirements.
Collapse
Affiliation(s)
- Mariana Coelly Modesto Santos Tavares
- Environment Livestock Research Group (NUPEA), Department of Biosystems Engineering, "Luiz de Queiroz" College of Agriculture (ESALQ), University of São Paulo (USP), Piracicaba, São Paulo, Brazil
| | - Robson Mateus Freitas Silveira
- Department of Animal Science, "Luiz de Queiroz" College of Agriculture (ESALQ), University of São Paulo (USP), Piracicaba, São Paulo, Brazil
| | - Alessandra Arno
- Environment Livestock Research Group (NUPEA), Department of Biosystems Engineering, "Luiz de Queiroz" College of Agriculture (ESALQ), University of São Paulo (USP), Piracicaba, São Paulo, Brazil
| | - Idemauro Antonio Rodrigues de Lara
- Department of Exact Sciences, "Luiz de Queiroz" College of Agriculture (ESALQ), University of São Paulo (USP), Piracicaba, São Paulo, Brazil
| | - Maria Letícia Salvador
- Department of Exact Sciences, "Luiz de Queiroz" College of Agriculture (ESALQ), University of São Paulo (USP), Piracicaba, São Paulo, Brazil
| | - Silvia Maria de Freitas
- Department of Statistics and Applied Mathematics, Federal University of Ceará, Campus Do Pici, Science Center, Block 910, Fortaleza, CE, CEP: 60440-900, Brazil
| | - Iran José Oliveira da Silva
- Environment Livestock Research Group (NUPEA), Department of Biosystems Engineering, "Luiz de Queiroz" College of Agriculture (ESALQ), University of São Paulo (USP), Piracicaba, São Paulo, Brazil.
| |
Collapse
|
3
|
Ji C, Zhang L, Wang Y, Lin B, Bai X, Yun S, He B. The influence of different shaped osteocyte lacunae on microcrack initiation and propagation. Clin Biomech (Bristol, Avon) 2023; 108:106072. [PMID: 37611387 DOI: 10.1016/j.clinbiomech.2023.106072] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 04/28/2023] [Revised: 08/12/2023] [Accepted: 08/16/2023] [Indexed: 08/25/2023]
Abstract
BACKGROUND The morphology of osteocyte lacunae varies in bones of different ages and bone pathologies. Osteocyte lacunae can cause stress concentration and initiate microcracks. However, the influence of changes in osteocyte lacunar shape on microcrack is unknown. Therefore, the aim of this study was to determine the effects of osteocyte lacunae with different shapes on microcrack initiation and propagation. METHODS Osteon models containing osteocyte lacunae with different shapes were established. The progressive damage analysis method, based on computer simulations, was used to study the evolution of microdamage within the osteon, including the processes of intralaminar and interlaminar microdamage. FINDINGS Models with larger DoE values can effectively delay or prevent the formation of linear microcracks, which ensures high fracture toughness of cortical bone. It is subjected to stronger mechanical stimulation, making it more sensitive to loads. Models with smaller DoE values increase the load threshold for microdamage generation and reduces its impact on bone mechanical performance, making it less susceptible to microdamage than models with larger DoE values. INTERPRETATION These findings enhance the limited knowledge of the influence of the lacunar shape on microdamage and contribute to a better understanding of bone biomechanics.
Collapse
Affiliation(s)
- Chunhui Ji
- School of Mechanical Engineering, Tianjin University, Tianjin 300072, PR China
| | - Liang Zhang
- School of Mechanical Engineering, Tianjin University, Tianjin 300072, PR China
| | - Yan Wang
- Tianjin Hospital, Tianjin University, Tianjin 300072, PR China
| | - Bin Lin
- School of Mechanical Engineering, Tianjin University, Tianjin 300072, PR China.
| | - Xinlei Bai
- School of Mechanical Engineering, Tianjin University, Tianjin 300072, PR China
| | - Shiyue Yun
- School of Mechanical Engineering, Tianjin University, Tianjin 300072, PR China
| | - Bingnan He
- School of Mechanical Engineering, Tianjin University, Tianjin 300072, PR China
| |
Collapse
|
4
|
Monahan GE, Schiavi-Tritz J, Britton M, Vaughan TJ. Longitudinal alterations in bone morphometry, mechanical integrity and composition in Type-2 diabetes in a Zucker diabetic fatty (ZDF) rat. Bone 2023; 170:116672. [PMID: 36646266 DOI: 10.1016/j.bone.2023.116672] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 11/04/2022] [Revised: 12/30/2022] [Accepted: 01/03/2023] [Indexed: 01/15/2023]
Abstract
Individuals with Type-2 Diabetes (T2D) have an increased risk of bone fracture, without a reduction in bone mineral density. It is hypothesised that the hyperglycaemic state caused by T2D forms an excess of Advanced Glycated End-products (AGEs) in the organic matrix of bone, which are thought to stiffen the collagen network and lead to impaired mechanical properties. However, the mechanisms are not well understood. This study aimed to investigate the geometrical, structural and material properties of diabetic cortical bone during the development and progression of T2D in ZDF (fa/fa) rats at 12-, 26- and 46-weeks of age. Longitudinal bone growth was impaired as early as 12-weeks of age and by 46-weeks bone size was significantly reduced in ZDF (fa/fa) rats versus controls (fa/+). Diabetic rats had significant structural deficits, such as bending rigidity, ultimate moment and energy-to-failure measured via three-point bend testing. Tissue material properties, measured by taking bone geometry into account, were altered as the disease progressed, with significant reductions in yield and ultimate strength for ZDF (fa/fa) rats at 46-weeks. FTIR analysis on cortical bone powder demonstrated that the tissue material deficits coincided with changes in tissue composition, in ZDF (fa/fa) rats with long-term diabetes having a reduced carbonate:phosphate ratio and increased acid phosphate content when compared to age-matched controls, indicative of an altered bone turnover process. AGE accumulation, measured via fluorescent assays, was higher in the skin of ZDF (fa/fa) rats with long-term T2D, bone AGEs did not differ between strains and neither AGEs correlated with bone strength. In conclusion, bone fragility in the diabetic ZDF (fa/fa) rats likely occurs through a multifactorial mechanism influenced initially by impaired bone growth and development and proceeding to an altered bone turnover process that reduces bone quality and impairs biomechanical properties as the disease progresses.
Collapse
Affiliation(s)
- Genna E Monahan
- Biomechanics Research Centre (BioMEC), Biomedical Engineering, College of Science and Engineering, University of Galway, Galway, Ireland
| | - Jessica Schiavi-Tritz
- Biomechanics Research Centre (BioMEC), Biomedical Engineering, College of Science and Engineering, University of Galway, Galway, Ireland; Laboratoire Réactions et Génie des Procédés, Université de Lorraine, CNRS UMR, 7274 Nancy, France
| | - Marissa Britton
- Biomechanics Research Centre (BioMEC), Biomedical Engineering, College of Science and Engineering, University of Galway, Galway, Ireland
| | - Ted J Vaughan
- Biomechanics Research Centre (BioMEC), Biomedical Engineering, College of Science and Engineering, University of Galway, Galway, Ireland.
| |
Collapse
|
5
|
Walle M, Whittier DE, Schenk D, Atkins PR, Blauth M, Zysset P, Lippuner K, Müller R, Collins CJ. Precision of bone mechanoregulation assessment in humans using longitudinal high-resolution peripheral quantitative computed tomography in vivo. Bone 2023; 172:116780. [PMID: 37137459 DOI: 10.1016/j.bone.2023.116780] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 02/16/2023] [Revised: 03/31/2023] [Accepted: 04/20/2023] [Indexed: 05/05/2023]
Abstract
Local mechanical stimuli in the bone microenvironment are essential for the homeostasis and adaptation of the skeleton, with evidence suggesting that disruption of the mechanically-driven bone remodelling process may lead to bone loss. Longitudinal clinical studies have shown the combined use of high-resolution peripheral quantitative computed tomography (HR-pQCT) and micro-finite element analysis can be used to measure load-driven bone remodelling in vivo; however, quantitative markers of bone mechanoregulation and the precision of these analyses methods have not been validated in human subjects. Therefore, this study utilised participants from two cohorts. A same-day cohort (n = 33) was used to develop a filtering strategy to minimise false detections of bone remodelling sites caused by noise and motion artefacts present in HR-pQCT scans. A longitudinal cohort (n = 19) was used to develop bone imaging markers of trabecular bone mechanoregulation and characterise the precision for detecting longitudinal changes in subjects. Specifically, we described local load-driven formation and resorption sites independently using patient-specific odds ratios (OR) and 99 % confidence intervals. Conditional probability curves were computed to link the mechanical environment to the remodelling events detected on the bone surface. To quantify overall mechanoregulation, we calculated a correct classification rate measuring the fraction of remodelling events correctly identified by the mechanical signal. Precision was calculated as root-mean-squared averages of the coefficient of variation (RMS-SD) of repeated measurements using scan-rescan pairs at baseline combined with a one-year follow-up scan. We found no significant mean difference (p < 0.01) between scan-rescan conditional probabilities. RMS-SD was 10.5 % for resorption odds, 6.3 % for formation odds, and 1.3 % for correct classification rates. Bone was most likely to be formed in high-strain and resorbed in low-strain regions for all participants, indicating a consistent, regulated response to mechanical stimuli. For each percent increase in strain, the likelihood of bone resorption decreased by 2.0 ± 0.2 %, and the likelihood of bone formation increased by 1.9 ± 0.2 %, totalling 38.3 ± 1.1 % of strain-driven remodelling events across the entire trabecular compartment. This work provides novel robust bone mechanoregulation markers and their precision for designing future clinical studies.
Collapse
Affiliation(s)
- Matthias Walle
- Institute for Biomechanics, ETH Zurich, Zurich, Switzerland
| | - Danielle E Whittier
- Institute for Biomechanics, ETH Zurich, Zurich, Switzerland; Department of Osteoporosis, Bern University Hospital, Bern, Switzerland
| | - Denis Schenk
- ARTORG Center for Biomedical Engineering Research, University of Bern, Bern, Switzerland
| | - Penny R Atkins
- Institute for Biomechanics, ETH Zurich, Zurich, Switzerland; Department of Osteoporosis, Bern University Hospital, Bern, Switzerland
| | - Michael Blauth
- Department of Orthopaedics and Traumatology, Medical University Innsbruck, Innsbruck, Austria
| | - Philippe Zysset
- ARTORG Center for Biomedical Engineering Research, University of Bern, Bern, Switzerland
| | - Kurt Lippuner
- Department of Osteoporosis, Bern University Hospital, Bern, Switzerland
| | - Ralph Müller
- Institute for Biomechanics, ETH Zurich, Zurich, Switzerland
| | - Caitlyn J Collins
- Institute for Biomechanics, ETH Zurich, Zurich, Switzerland; Virginia Tech, Department of Biomedical Engineering and Mechanics, Blacksburg, VA, United States.
| |
Collapse
|
6
|
La Mattina AA, Baruffaldi F, Taylor M, Viceconti M. Statistical Properties of a Virtual Cohort for In Silico Trials Generated with a Statistical Anatomy Atlas. Ann Biomed Eng 2023; 51:117-124. [PMID: 36066781 PMCID: PMC9832093 DOI: 10.1007/s10439-022-03050-8] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/14/2022] [Accepted: 08/06/2022] [Indexed: 01/28/2023]
Abstract
Osteoporosis-related hip fragility fractures are a catastrophic event for patient lives but are not frequently observed in prospective studies, and therefore phase III clinical trials using fractures as primary clinical endpoint require thousands of patients enrolled for several years to reach statistical significance. A novel answer to the large number of subjects needed to reach the desired evidence level is offered by In Silico Trials, that is, the simulation of a clinical trial on a large cohort of virtual patients, monitoring the biomarkers of interest. In this work we investigated if statistical aliasing from a custom anatomy atlas could be used to expand the patient cohort while retaining the original biomechanical characteristics. We used a pair-matched cohort of 94 post-menopausal women (at the time of the CT scan, 47 fractured and 47 not fractured) to create a statistical anatomy atlas through principal component analysis, and up-sampled the atlas in order to obtain over 1000 synthetic patient models. We applied the biomechanical computed tomography pipeline to the resulting virtual cohort and compared its fracture risk distribution with that of the original physical cohort. While the distribution of femoral strength values in the non-fractured sub-group was nearly identical to that of the original physical cohort, that of the fractured sub-group was lower than in the physical cohort. Nonetheless, by using the classification threshold used for the original population, the synthetic population was still divided into two parts of approximatively equal number.
Collapse
Affiliation(s)
- Antonino A. La Mattina
- grid.6292.f0000 0004 1757 1758Department of Industrial Engineering, Alma Mater Studiorum - University of Bologna (IT), Bologna, Italy ,grid.419038.70000 0001 2154 6641Medical Technology Lab, IRCCS Istituto Ortopedico Rizzoli, Via di Barbiano 1/10, 40136 Bologna, Italy
| | - Fabio Baruffaldi
- grid.419038.70000 0001 2154 6641Medical Technology Lab, IRCCS Istituto Ortopedico Rizzoli, Via di Barbiano 1/10, 40136 Bologna, Italy
| | - Mark Taylor
- grid.1014.40000 0004 0367 2697Medical Device Research Institute, College of Science and Engineering, Flinders University, Adelaide, Australia
| | - Marco Viceconti
- grid.6292.f0000 0004 1757 1758Department of Industrial Engineering, Alma Mater Studiorum - University of Bologna (IT), Bologna, Italy ,grid.419038.70000 0001 2154 6641Medical Technology Lab, IRCCS Istituto Ortopedico Rizzoli, Via di Barbiano 1/10, 40136 Bologna, Italy
| |
Collapse
|
7
|
Cifuentes-Mendiola SE, Solís-Suárez DL, Martínez-Dávalos A, Perrusquía-Hernández E, García-Hernández AL. Aerobic training improves bone fragility by reducing the inflammatory microenvironment in bone tissue in type 2 diabetes. J Biomech 2022; 145:111354. [PMID: 36335825 DOI: 10.1016/j.jbiomech.2022.111354] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/23/2022] [Revised: 10/13/2022] [Accepted: 10/16/2022] [Indexed: 11/06/2022]
Abstract
Aerobic training (AT) is indicated in type 2 diabetes mellitus (T2DM) to control hyperglycaemia and inflammation. AT improves bone microarchitecture and resistance to fracture. The intensity of AT and the mechanisms that lead to the improvement in bone quality are still unknown. Using a mouse model of T2DM, we evaluated the effects of two intensities of forced AT. We divided mice into: sedentary (SED), T2DM-SED, low runners (LOW), T2DM-LOW, high runners (HIGH) and T2DM-HIGH. The AT for low was 8 m/minute (m/min); 5° slope or high 18 m/min; 15° slope for 2 months. We measured metabolic parameters, the serum cytokines concentration, lipocalin-2 (LCN-2) and adiponectin; and the tibial concentrations of LCN-2, tumour necrosis factor alpha (TNF-α) and protein carbonylation (CO). We evaluated femur morphometry and biomechanical properties. We performed multiple correlation analysis. The T2DM-LOW versus T2DM-SED group, shown an increase of interleukin (IL)-10 (417 ± 90 vs 102 ± 25 pg/mL) and improved trabecular bone (BV/TV: 31.8 ± 2.3 vs 19.25 ± 1.4%; Tb.Sp.: 1.62 ± 0.02 vs 2.0 ± 0.07 mm), by a decrease bone CO (3.4 ± 0.1 vs 6.0 ± 0.5 nmol/mg), bone TNF-α (84 ± 4 vs 239 ± 13 pg/mL) and LCN-2 (2887 ± 23 vs 3418 ± 105 pg/mL). The T2DM-HIGH versus T2DM-SED group showed a greater hypoglycaemic effect (228 ± 10 vs 408 ± 5 mg/dL), with improved cortical bone density (0.26 ± 0.012 vs 0.21 ± 0.007 mm) and fracture resistance (102 ± 8 vs 78 ± 5 MPa), by a reduction of bone TNF-α (77 ± 34 vs 239 ± 13 pg/mL); LCN-2 (2768 ± 20 vs 3418 ± 105 pg/mL) and CO (4.8 ± 0.5 vs 6.0 ± 0.5 nmol/mg). In conclusion, AT improves bone morphometry and biomechanical properties by reducing the bone inflammatory microenvironment.
Collapse
Affiliation(s)
- Saúl Ernesto Cifuentes-Mendiola
- Laboratory of Dental Research, Section of Osteoimmunology and Oral Immunology. FES Iztacala, National Autonomous University of Mexico (UNAM), Mexico; Postgraduate in Biological Sciences. National Autonomous University of Mexico (UNAM), Mexico City, Mexico
| | - Diana Laura Solís-Suárez
- Laboratory of Dental Research, Section of Osteoimmunology and Oral Immunology. FES Iztacala, National Autonomous University of Mexico (UNAM), Mexico; Postgraduate in Dentistry Sciencies. National Autonomous University of Mexico (UNAM), Mexico City, Mexico
| | | | - Elías Perrusquía-Hernández
- Laboratory of Dental Research, Neurobiology of Oral Sensations and Movements Section, FES Iztacala, National Autonomous University of Mexico (UNAM), Mexico
| | - Ana Lilia García-Hernández
- Laboratory of Dental Research, Section of Osteoimmunology and Oral Immunology. FES Iztacala, National Autonomous University of Mexico (UNAM), Mexico.
| |
Collapse
|
8
|
Gürgül S, Keskin Ö, Demirel C, Yaşar Özkars M, Nural Y. Does anti-IgE therapy prevent chronic allergic asthma-related bone deterioration in asthmatic mice? J Biomech 2022; 141:111180. [PMID: 35724549 DOI: 10.1016/j.jbiomech.2022.111180] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/03/2021] [Revised: 06/06/2022] [Accepted: 06/06/2022] [Indexed: 11/21/2022]
Abstract
Current evidence on the association between allergic diseases and bone metabolism indicates asthma may be a potential risk factor for bone health. Using anti-IgE has been proven effective in allergic asthma treatment with a good safety profile; however, its effects on bone health are unknown. Thus, we aimed to investigate whether: (i) chronic allergic asthma (CAA) causes any meaningful changes in bone, and if any, (ii) anti-IgE therapy prevents any CAA-induced adverse alteration. A murine model was used to study CAA. Thirty-two BALB/c male-mice were assigned into four groups (eight-mice/group): Control, CAA (treated with saline), CAA + 100 µg of anti-IgE (CAA + 100AIgE), and CAA + 200 µg of anti-IgE (CAA + 200AIgE) groups. After immunization, saline or anti-IgE was performed intraperitoneally for 8-weeks (in five-sessions at 15-days interval). Three-point bending test was used for the mechanical analysis. Bone calcium (Ca2+) and phosphorus (P3-) as well as Ca/P ratio were evaluated using inductively-coupled plasma-mass-spectrometer (ICP-MS). Compared to control, reductions observed in yield and ultimate moments, rigidity, energy-to-failure, yield and ultimate stresses, elastic modulus, toughness, and post-yield toughness parameters of the CAA group were found significant (P < 0.05). Similar declines were also detected regarding bone Ca2+, P3- and Ca/P ratio (P < 0.05). Compared to control, we observed that 200 µg administration of anti-IgE in CAA + 200AIgE group hindered CAA-related impairments in mineral and mechanical characteristics of bone, while 100 µg in CAA + 100AIgE failed to do so. Our results showed CAA may cause bone loss, leading to a decrease in bone strength, and anti-IgE administration may dose-dependently inhibit these impairments in bone.
Collapse
|
9
|
Klinger S, Greinwald M, Augat P, Hollensteiner M. Mechanical and morphometric characterization of custom-made trabecular bone surrogates. J Mech Behav Biomed Mater 2022; 129:105146. [PMID: 35247861 DOI: 10.1016/j.jmbbm.2022.105146] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/09/2021] [Revised: 10/14/2021] [Accepted: 02/26/2022] [Indexed: 10/19/2022]
Abstract
Synthetic bones for biomechanical testing and surgeon training have become more important due to their numerous advantages compared to human bones. Several bone models are already available on the market, but most of them do not reflect the full range of versatile properties that characterize human bone like population-level influences, size, stiffness, bone-implant-interface or morphometry. Thus, the objectives of this study were to develop synthetic trabecular bone surrogates from polyurethane and varying additives and to determine their elastic and plastic mechanical compressive and additionally morphometric properties. Another aim was to investigate the influence of varying additives on aforementioned properties and finally compare the results with published data from human trabecular bone. Additives used were blowing agents to create a porous structure, mineral fillers to manipulate the basic polyurethane resin, and cell stabilizers to achieve an open porous composition. Mechanical properties were obtained from static compression tests until failure while morphometric analysis was carried out using microcomputed tomography. Thereby, the blowing agent showed the strongest influence on mechanical and morphometric properties with mean Young's moduli ranging from 627 ± 37 MPa (0% blowing agent) to 154 ± 15 MPa (0.25% blowing agent) while the variation of mineral filler content resulted in small standard deviations of approximately 10-20 MPa with a constant proportion of blowing agent. The achieved mechanical properties of the developed synthetic bones, such as the Young's modulus, ultimate stress and yield stress were in accordance with human trabecular bone, while yield strain for all groups was noticeably higher compared to human trabecular bone. Additionally, morphometric analysis showed results indicating similar morphometry of the custom-made synthetic bone and human cancellous bone. Although recreating bone structures in physiological conditions is not simple, the results of the current study show the possibility of developing synthetic bone materials with characteristics like human trabecular bone.
Collapse
Affiliation(s)
- Simon Klinger
- Institute for Biomechanics, BG Unfallklinik Murnau and Paracelsus Medical University Salzburg, Prof.-Küntscher-Straße 8, 82418, Murnau, Germany; Ostbayerische Technische Hochschule Regensburg, Galgenbergstraße 30, 93053, Regensburg, Germany
| | - Markus Greinwald
- Institute for Biomechanics, BG Unfallklinik Murnau and Paracelsus Medical University Salzburg, Prof.-Küntscher-Straße 8, 82418, Murnau, Germany
| | - Peter Augat
- Institute for Biomechanics, BG Unfallklinik Murnau and Paracelsus Medical University Salzburg, Prof.-Küntscher-Straße 8, 82418, Murnau, Germany
| | - Marianne Hollensteiner
- Institute for Biomechanics, BG Unfallklinik Murnau and Paracelsus Medical University Salzburg, Prof.-Küntscher-Straße 8, 82418, Murnau, Germany.
| |
Collapse
|
10
|
Albert DL, Katzenberger MJ, Agnew AM, Kemper AR. A comparison of rib cortical bone compressive and tensile material properties: Trends with age, sex, and loading rate. J Mech Behav Biomed Mater 2021; 122:104668. [PMID: 34265671 DOI: 10.1016/j.jmbbm.2021.104668] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/25/2021] [Revised: 06/16/2021] [Accepted: 06/26/2021] [Indexed: 11/18/2022]
Abstract
The objectives of this study were to develop novel methods for quantifying human rib cortical bone material properties in compression and to compare the compressive material property data to existing tensile data for matched subjects. Cylindrical coupons were obtained from the rib cortical bone of 30 subjects (M = 19, F = 11) ranging from 18 to 95 years of age (Avg. = 48.5 ± 24.3). Two coupons were obtained from each subject. One coupon was tested in compression at 0.005 strain/s, while the other coupon was tested in compression at 0.5 strain/s. Load and displacement data were recorded so that the elastic modulus, yield stress, yield strain, ultimate stress, ultimate strain, elastic strain energy density (SED), plastic SED, and total SED could be calculated. All compressive material properties were significantly different between the two loading rates. An ANOVA revealed that sex alone had no significant effect on the compressive material properties. The interaction between sex and age was significant for some material properties, but this may have been a consequence of the lack of older females in the subject pool. None of the compressive material properties were significantly correlated with age, but were more correlated with sample density. This finding differed for the tensile material properties, which showed stronger correlations with age. When comparing between tension and compression, significant differences were observed for all material properties except for the total SED, once the effects of loading rate and age had been accounted for. This was the first study to quantify the material properties of human rib cortical bone in compression. The results of this study demonstrated that rib and thorax finite element models should consider the effects of loading rate, loading mode, and age when incorporating material properties published in the literature.
Collapse
Affiliation(s)
- Devon L Albert
- Virginia Tech - Wake Forest, Center for Injury Biomechanics, USA
| | | | - Amanda M Agnew
- The Ohio State University, Injury Biomechanics Research Center, USA
| | - Andrew R Kemper
- Virginia Tech - Wake Forest, Center for Injury Biomechanics, USA.
| |
Collapse
|
11
|
Bizzoca D, Vicenti G, Caiaffa V, Abate A, De Carolis O, Carrozzo M, Solarino G, Moretti B. Assessment of fracture healing in orthopaedic trauma. Injury 2020; 54 Suppl 1:S46-S52. [PMID: 33234266 DOI: 10.1016/j.injury.2020.11.014] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 08/29/2020] [Accepted: 11/05/2020] [Indexed: 02/02/2023]
Abstract
Fracture healing is a complex physiologic process, relying on the crucial interplay between biological and mechanical factors. It is generally assessed using imaging modalities, including conventional radiology, CT, MRI and ultrasound (US), based on the fracture and patient features. Although these techniques are routinely used in orthopaedic clinical practice, unfortunately, they do not provide any information about the biomechanical status of the fracture site. Therefore, in recent years, several non-invasive techniques have been proposed to assess bone healing using ultrasonic wave propagation, changes in electrical properties of bones and callus stiffness measurement. Moreover, different research groups are currently developing smart orthopaedic implants (plates, intramedullary nails and external fixators), able to provide information about the fracture healing process. These devices could significantly improve orthopaedic and trauma clinical practice in the future and, at the same time, reduce patients' exposure to X-rays. This study aims to define the role of traditional imaging techniques and emerging technologies in the assessment of the fracture healing process.
Collapse
Affiliation(s)
- Davide Bizzoca
- School of Medicine, University of Bari Aldo Moro, AOU Consorziale "Policlinico", Department of Basic Medical Sciences, Neuroscience and Sense Organs, Orthopaedic & Trauma Unit, Bari, Italy
| | - Giovanni Vicenti
- School of Medicine, University of Bari Aldo Moro, AOU Consorziale "Policlinico", Department of Basic Medical Sciences, Neuroscience and Sense Organs, Orthopaedic & Trauma Unit, Bari, Italy.
| | - Vincenzo Caiaffa
- Orthopaedic and Traumatology Unit, "Di Venere" Hospital, Bari, Italy
| | - Antonella Abate
- Orthopaedic and Traumatology Unit, "Di Venere" Hospital, Bari, Italy
| | - Oronzo De Carolis
- Orthopaedic and Traumatology Unit, "Di Venere" Hospital, Bari, Italy
| | - Massimiliano Carrozzo
- School of Medicine, University of Bari Aldo Moro, AOU Consorziale "Policlinico", Department of Basic Medical Sciences, Neuroscience and Sense Organs, Orthopaedic & Trauma Unit, Bari, Italy
| | - Giuseppe Solarino
- School of Medicine, University of Bari Aldo Moro, AOU Consorziale "Policlinico", Department of Basic Medical Sciences, Neuroscience and Sense Organs, Orthopaedic & Trauma Unit, Bari, Italy
| | - Biagio Moretti
- School of Medicine, University of Bari Aldo Moro, AOU Consorziale "Policlinico", Department of Basic Medical Sciences, Neuroscience and Sense Organs, Orthopaedic & Trauma Unit, Bari, Italy
| |
Collapse
|
12
|
Roux JP, Boutroy S, Bouxsein ML, Chapurlat R, Wegrzyn J. Local and global microarchitecture is associated with different features of bone biomechanics. Bone Rep 2020; 13:100716. [PMID: 32995387 DOI: 10.1016/j.bonr.2020.100716] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [What about the content of this article? (0)] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 05/29/2020] [Revised: 08/31/2020] [Accepted: 09/14/2020] [Indexed: 11/21/2022] Open
Abstract
Purpose Beside areal bone mineral density (aBMD), evaluation of fragility fracture risk mostly relies on global microarchitecture. However, microarchitecture is not a uniform network. Therefore, this study aimed to compare local structural weakness to global microarchitecture on whole vertebral bodies and to evaluate how local and global microarchitecture was associated with bone biomechanics. Methods From 21 human L3 vertebrae, aBMD was measured using absorptiometry. Parameters of global microarchitecture were measured using HR-pQCT: trabecular bone volume fraction (Tb.BV/TVglobal), trabecular number, structure model index and connectivity density (Conn.D). Local minimal values of aBMD and Tb.BV/TV were identified in the total (Tt) or trabecular (Tb) area of each vertebral body. “Two dimensional (2D) local structural weakness” was defined as Tt.BMDmin, Tt.BV/TVmin and Tb.BV/TVmin. Mechanical testing was performed in 3 phases: 1/ initial compression until mild vertebral fracture, 2/ unloaded relaxation, and 3/ second compression until failure. Results Initial and post-fracture mechanics were significantly correlated with bone mass, global and local microarchitecture. Tt.BMDmin, Tt.BV/TVmin, Tb.BV/TVmin, and initial and post-fracture mechanics remained significantly correlated after adjustment for aBMD or Tb.BV/TVglobal (p < 0.001 to 0.038). The combination of the most relevant parameter of bone mass, global and local microarchitecture associated with failure load and stiffness demonstrated that global microarchitecture explained initial and post-fracture stiffness, while local structural weakness explained initial and post-fracture failure load (p < 0.001). Conclusion Local and global microarchitecture was associated with different features of vertebral bone biomechanics, with global microarchitecture controlling stiffness and 2D local structural weakness controlling strength. Therefore, determining both localized low density and impaired global microarchitecture could have major impact on vertebral fracture risk prediction. Global and local microarchitecture were associated with different features of bone biomechanics. Localized low density and/or impaired microarchitecture regions could have major impact on bone mechanical behavior. Global microarchitecture determined initial and post-fracture vertebral stiffness. Local microarchitecture determined initial and post-fracture vertebral failure load.
Collapse
|
13
|
Koria L, Mengoni M, Brockett C. Estimating tissue-level properties of porcine talar subchondral bone. J Mech Behav Biomed Mater 2020; 110:103931. [PMID: 32805501 DOI: 10.1016/j.jmbbm.2020.103931] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [What about the content of this article? (0)] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/26/2019] [Revised: 06/05/2020] [Accepted: 06/10/2020] [Indexed: 11/21/2022]
Abstract
Tissue-level properties of bone play an important role when characterising apparent-level bone biomechanical behaviour and yet little is known about its effect at this hierarchical level. In combination with trabecular morphological data these properties can be used to predict bone strength, which becomes an invaluable tool for clinicians in patient treatment planning. This study developed specimen-specific micro-finite element (μFE) models using validated continuum-level models, containing grayscale-derived material properties, to indirectly establish tissue-level properties of porcine talar subchondral bone. Specimen-specific continuum finite element (hFE) models of subchondral trabecular bone were setup using μCT data of ten cylindrical specimens extracted from juvenile porcine tali. The models were validated using quasi-static uniaxial compression testing. Validated hFE models were used to calibrate the tissue modulus of corresponding μFE models by minimising the difference between the μFE and hFE stiffness values. Key trabecular morphological indices (BV/TV, DA, Conn.D, Tb.Th, EF) were evaluated. Good agreement was observed between hFE models and experiment (CCC = 0.66). Calibrated Etiss was 504 ± 37.65 MPa. Average BV/TV and DA for μFE specimens were 0.37 ± 0.05 and 0.68 ± 0.11, respectively. BV/TV (r2 = 0.667) correlated highly with μFE stiffness. The small intra-specimen variation to tissue-level properties suggests that variations to apparent-level stiffness originate from variations to microarchitecture rather than tissue mechanical properties.
Collapse
|
14
|
Jin Y, Zhang T, Cheung JPY, Wong TM, Feng X, Sun T, Zu H, Sze KY, Lu WW. A novel mechanical parameter to quantify the microarchitecture effect on apparent modulus of trabecular bone: A computational analysis of ineffective bone mass. Bone 2020; 135:115314. [PMID: 32156663 DOI: 10.1016/j.bone.2020.115314] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 12/02/2019] [Revised: 03/03/2020] [Accepted: 03/06/2020] [Indexed: 11/30/2022]
Abstract
BACKGROUND One of the characteristics of osteoporotic bone is the deterioration of trabecular microarchitecture. Previous studies have shown microarchitecture alone can vary the apparent modulus of trabecular bone significantly independent of bone volume fraction (BV/TV) from morphological and topological perspectives. However, modulus is a mechanical quantity and there is a lack of mechanical explanatory parameters. This study aims to propose a novel mechanical parameter to quantify the microarchitecture effect on the apparent modulus of trabecular bone. MATERIALS AND METHODS Fourteen human female cadaveric vertebrae were scanned with a dual-energy X-ray (DXA) equipment followed by a micro-CT (μCT) system at 18 μm isotropic resolution. Four trabecular bone specimens (3.46 × 3.46 × 3.46 mm) were obtained from each vertebral body and converted to voxel-based micro finite element (μFE) models. The apparent modulus (E) of the μFE model was computed using a linear micro finite element analysis (μFEA). The normalized apparent modulus (E*) was computed as E divided by BV/TV. The relationship between E and BV/TV was analyzed by linear, power-law and exponential regressions. Linear regression was performed between E* and BV/TV. Ineffective bone mass (InBM) was defined as the bone mass with a negligible contribution to the load-resistance and represented by elements with von Mises stress less than a certain stress threshold. InBM was quantified as the low von Mises stress ratio (LSVMR), which is the ratio of the number of InBM elements to the total number of elements in the μFE model. An incremental search technique with coarse and fine search intervals of 10 and 1 MPa, respectively, was adopted to determine the stress threshold for calculating LSVMR of the μFE model. Correlation between E* and LSVMR was analyzed using linear and power-law models for each stress threshold. The threshold producing the highest coefficient of determination (R2) in the correlation between E* and LSVMR was taken as the optimal stress threshold for calculating LSVMR. Linear regression was performed between E and LSVMR. Multiple linear regression of E against both BV/TV and LSVMR was further analyzed. RESULTS E significantly (p < .001) correlates to BV/TV whereas E* has no significant (p = .75) correlation with BV/TV. Incremental search suggests 59 MPa to be the optimal stress threshold for calculating LSVMR. BV/TV alone can explain 59% of the variation in E using power-law regression model (E = 2254.64BV/TV1.04, R2 = 0.59, p < .001). LSVMR alone can explain 48% of the variation in E using linear regression model (E = 1696.4-1647.1LSVMR, R2 = 0.48, p < .001). With these two predictors taken into consideration, 95% of the variation in E can be explained in a multiple linear regression model (E = 1364.89 + 2184.37BV/TV - 1605.38LSVMR, adjusted R2 = 0.95, p < .001). CONCLUSION LSVMR can be adopted as the mechanical parameter to quantify the microarchitecture effect on the apparent modulus of trabecular bone.
Collapse
Affiliation(s)
- Yongqiang Jin
- Department of Orthopaedics and Traumatology, Li Ka Shing Faculty of Medicine, The University of Hong Kong, Hong Kong, China
| | - Teng Zhang
- Department of Orthopaedics and Traumatology, Li Ka Shing Faculty of Medicine, The University of Hong Kong, Hong Kong, China.
| | - Jason Pui Yin Cheung
- Department of Orthopaedics and Traumatology, Li Ka Shing Faculty of Medicine, The University of Hong Kong, Hong Kong, China
| | - Tak Man Wong
- Department of Orthopaedics and Traumatology, Li Ka Shing Faculty of Medicine, The University of Hong Kong, Hong Kong, China
| | - Xiaoreng Feng
- Department of Orthopaedics and Traumatology, Li Ka Shing Faculty of Medicine, The University of Hong Kong, Hong Kong, China
| | - Tianhao Sun
- Department of Orthopaedics and Traumatology, The University of Hong Kong - Shenzhen Hospital, Shenzhen, China
| | - Haiyue Zu
- Department of Orthopaedics and Traumatology, Faculty of Medicine, The Chinese University of Hong Kong, Hong Kong, China
| | - Kam Yim Sze
- Department of Mechanical Engineering, Faculty of Engineering, The University of Hong Kong, Hong Kong, China.
| | - William Weijia Lu
- Department of Orthopaedics and Traumatology, Li Ka Shing Faculty of Medicine, The University of Hong Kong, Hong Kong, China
| |
Collapse
|
15
|
Koirala N, McLennan G. Percutaneous reinforced osteoplasty for long bone metastases: a feasibility study. Skeletal Radiol 2020; 49:375-382. [PMID: 31377837 DOI: 10.1007/s00256-019-03288-9] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 05/19/2019] [Revised: 07/03/2019] [Accepted: 07/22/2019] [Indexed: 02/02/2023]
Abstract
OBJECTIVE While percutaneous osteoplasty is common for the treatment of vertebral fractures, low strength of fixation remains a major challenge for use in metastatic weight-bearing bones. With stent, wire, and cement augmentation, this study explores the feasibility of percutaneous reinforced osteoplasty for use in correcting long bone fractures. MATERIALS AND METHODS Fifteen explanted swine femora were randomly assigned into three groups. Group 1 (n = 5) was native (intact) bones without any intervention (control), group 2 (n = 5) received cementoplasty, and group 3 (n = 5) received stent and wire scaffolding ("rebar") in addition to cementoplasty. All treatment procedures were performed under fluoroscopic guidance. Mechanical strength of fracture fixation was quantified by peak load to failure, stiffness, work done to fracture, and fatigue testing with four-point bend test. RESULTS Percutaneous osteoplasty with or without reinforcement was successfully achieved in all specimens. The respective peak load at failure, flexural stiffness, and work done to fracture (mean ± SEM) for group 1 was 2245 ± 168 N, 14.77 ± 1.3 Nm/degree, and 4854 ± 541 Nmm; group 2 was 468 ± 81 N, 3.9 ± 0.5 Nm/degree, and 401 ± 56 Nmm; and group 3 was 594 ± 90 N, 4.42 ± 0.4 Nm/degree, and 522 ± 54 Nmm. The mean cyclic displacement for groups 1, 2, and 3 were 0.15, 0.58, and 0.48 mm, respectively, at 220-240 N loading. CONCLUSIONS While percutaneous reinforced osteoplasty with stent, wire, and cement augmentation resulted in improved mechanical strength in restored bones, it did not differ significantly from specimens that underwent exclusive cementoplasty. With the improvement of fracture strength, the concept may be applicable for prevention or treatment of pathological fractures.
Collapse
Affiliation(s)
- Nischal Koirala
- Department of Chemical and Biomedical Engineering, Cleveland State University, 2121 Euclid Ave, Cleveland, OH, 44115, USA.,Department of Biomedical Engineering, Cleveland Clinic, 9500 Euclid Ave, Cleveland, OH, 44195, USA
| | - Gordon McLennan
- Department of Biomedical Engineering, Cleveland Clinic, 9500 Euclid Ave, Cleveland, OH, 44195, USA. .,Section of Vascular and Interventional Radiology, 9500 Euclid Ave, Mail Code: ND 20, Cleveland, OH, 44195, USA.
| |
Collapse
|
16
|
Yang L, Yang J, Pan T, Zhong X. Liraglutide increases bone formation and inhibits bone resorption in rats with glucocorticoid-induced osteoporosis. J Endocrinol Invest 2019; 42:1125-1131. [PMID: 30955181 DOI: 10.1007/s40618-019-01034-5] [Citation(s) in RCA: 21] [Impact Index Per Article: 4.2] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 10/26/2018] [Accepted: 03/15/2019] [Indexed: 02/07/2023]
Abstract
OBJECTIVE This study aimed to investigate the effects of liraglutide on bone metabolism markers in rat models with glucocorticoid-induced osteoporosis (GIOP), including the effects on bone mass, bone tissue microstructure, bone biomechanics, and bone turnover markers. METHOD Thirty male Sprague-Dawley rats aged 8 weeks were randomly divided into three groups: the control group (n = 10) was intramuscularly injected with an equal volume of 0.9% sodium chloride, the dexamethasone group (n = 10) was intramuscularly injected with dexamethasone at 1 mg/kg (twice a week) to induce GIOP, the dexamethasone plus liraglutide group (n = 10) was subcutaneously injected with liraglutide at 200 μg/kg daily, simultaneously. The bilateral femurs and the fifth lumbar vertebrae were collected after 12 weeks to perform micro-computed tomography and bone biomechanical examinations. Also, tartrate-resistant acid phosphatase (TRACP), cross-linked carboxy-terminal telopeptide of type I collagen (CTX-I), alkaline phosphatase (ALP), and osteocalcin (OC) were tested. RESULTS The bone mineral density (BMD), bone microstructure, and bone biomechanical markers reduced significantly in the dexamethasone group compared with the control group. The bone resorption indicators (TRACP and CTX-I) increased, while the bone formation indicators (ALP and OC) decreased. After liraglutide treatment, BMD, bone microstructure, and bone biomechanical markers improved significantly. Moreover, TRACP and CTX-I decreased significantly, while ALP and OC increased compared with the dexamethasone group. CONCLUSIONS Liraglutide improved BMD, bone microstructure, and bone strength and reversed GIOP, primarily through the reduction of bone resorption and promotion of bone formation.
Collapse
Affiliation(s)
- L Yang
- Department of Endocrinology, The Second Affiliated Hospital of Anhui Medical University, No. 678 Furong Road, Hefei, 230061, People's Republic of China
| | - J Yang
- Department of Endocrinology, The Second Affiliated Hospital of Anhui Medical University, No. 678 Furong Road, Hefei, 230061, People's Republic of China
| | - T Pan
- Department of Endocrinology, The Second Affiliated Hospital of Anhui Medical University, No. 678 Furong Road, Hefei, 230061, People's Republic of China
| | - X Zhong
- Department of Endocrinology, The Second Affiliated Hospital of Anhui Medical University, No. 678 Furong Road, Hefei, 230061, People's Republic of China.
| |
Collapse
|
17
|
Chandler H, Brooks DJ, Hattersley G, Bouxsein ML, Lanske B. Abaloparatide increases bone mineral density and bone strength in ovariectomized rabbits with glucocorticoid-induced osteopenia. Osteoporos Int 2019; 30:1607-1616. [PMID: 31053927 PMCID: PMC6663928 DOI: 10.1007/s00198-019-04999-4] [Citation(s) in RCA: 15] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 03/04/2019] [Accepted: 04/21/2019] [Indexed: 12/22/2022]
Abstract
UNLABELLED Glucorticoid (GC) therapy is the commonest cause of secondary osteoporosis. Ovariectomized rabbits receiving the GC methylprednisolone for 6 weeks exhibited relatively lower vertebral and femoral bone mass. Treatment with the PTH receptor agonist abaloparatide for 12 weeks during ongoing methylprednisolone administration increased cortical and trabecular bone mass and femur bending strength. INTRODUCTION Abaloparatide, an osteoanabolic PTHrP analog, increases bone mineral density (BMD) and reduces fracture risk in women with postmenopausal osteoporosis. This study assessed abaloparatide effects on BMD and bone strength in ovariectomized (OVX) rabbits with glucocorticoid (GC)-induced osteopenia. METHODS Thirty-two rabbits underwent OVX and 8 underwent sham surgery. One day later, 24 OVX rabbits began daily s.c. GC injections (methylprednisolone, 1 mg/kg/day) for 6 weeks, while 8 OVX and 8 sham controls received no GC. GC-challenged rabbits (8/group) then received GC (0.5 mg/kg/day) along with daily s.c. vehicle (GC-OVX), abaloparatide 5 μg/kg/day (ABL5), or 25 μg/kg/day (ABL25) for 12 weeks, and the no-GC OVX and sham controls received daily vehicle. RESULTS GC-OVX rabbits showed significant deficits in vertebral and proximal femur areal BMD, lower cortical area, thickness and volumetric BMD of the femur diaphysis, and reduced trabecular bone volume and volumetric BMD in the vertebra and distal femur versus sham controls. These deficits were significantly reversed in the ABL25 group, which also showed enhanced trabecular micro-architecture versus GC-OVX controls. Destructive bending tests showed significantly lower femur diaphysis ultimate load and bending rigidity of the femoral diaphysis in the GC-OVX group versus sham controls, whereas these parameters were similar in the ABL25 group vs sham controls. CONCLUSIONS Abaloparatide 25 μg/kg/day mitigated the adverse effects of GC administration on cortical and trabecular bone and improved femoral strength in OVX rabbits. These results suggest potential promise for abaloparatide as an investigational therapy for glucocorticoid-induced osteoporosis.
Collapse
Affiliation(s)
- H Chandler
- Radius Health Inc., 950 Winter Street, Waltham, MA, 02451, USA
| | - D J Brooks
- Center for Advanced Orthopaedic Studies, Beth Israel Deaconess Medical Center, Boston, MA, USA
| | - G Hattersley
- Radius Health Inc., 950 Winter Street, Waltham, MA, 02451, USA
| | - M L Bouxsein
- Center for Advanced Orthopaedic Studies, Beth Israel Deaconess Medical Center, Boston, MA, USA
- Department of Orthopedic Surgery, Harvard Medical School, Boston, MA, USA
| | - B Lanske
- Radius Health Inc., 950 Winter Street, Waltham, MA, 02451, USA.
| |
Collapse
|
18
|
Hong AL, Ispiryan M, Padalkar MV, Jones BC, Batzdorf AS, Shetye SS, Pleshko N, Rajapakse CS. MRI-derived bone porosity index correlates to bone composition and mechanical stiffness. Bone Rep 2019; 11:100213. [PMID: 31372372 PMCID: PMC6660551 DOI: 10.1016/j.bonr.2019.100213] [Citation(s) in RCA: 9] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 02/01/2019] [Revised: 06/13/2019] [Accepted: 06/19/2019] [Indexed: 01/11/2023] Open
Abstract
The MRI-derived porosity index (PI) is a non-invasively obtained biomarker based on an ultrashort echo time sequence that images both bound and pore water protons in bone, corresponding to water bound to organic collagenous matrix and freely moving water, respectively. This measure is known to strongly correlate with the actual volumetric cortical bone porosity. However, it is unknown whether PI may also be able to directly quantify bone organic composition and/or mechanical properties. We investigated this in human cadaveric tibiae by comparing PI values to near infrared spectral imaging (NIRSI) compositional data and mechanical compression data. Data were obtained from a cohort of eighteen tibiae from male and female donors with a mean ± SD age of 70 ± 21 years. Biomechanical stiffness in compression and NIRSI-derived collagen and bound water content all had significant inverse correlations with PI (r = −0.79, −0.73, and −0.95 and p = 0.002, 0.007, and <0.001, respectively). The MRI-derived bone PI alone was a moderate predictor of bone stiffness (R2 = 0.63, p = 0.002), and multivariate analyses showed that neither cortical bone cross-sectional area nor NIRSI values improved bone stiffness prediction compared to PI alone. However, NIRSI-obtained collagen and water data together were a moderate predictor of bone stiffness (R2 = 0.52, p = 0.04). Our data validates the MRI-derived porosity index as a strong predictor of organic composition of bone and a moderate predictor of bone stiffness, and also provides preliminary evidence that NIRSI measures may be useful in future pre-clinical studies on bone pathology.
Collapse
Affiliation(s)
- Abigail L Hong
- Department of Radiology, University of Pennsylvania, United States of America
| | - Mikayel Ispiryan
- Department of Radiology, University of Pennsylvania, United States of America
| | - Mugdha V Padalkar
- Department of Bioengineering, Temple University, United States of America
| | - Brandon C Jones
- Department of Radiology, University of Pennsylvania, United States of America.,Department of Orthopaedic Surgery, University of Pennsylvania, United States of America
| | | | - Snehal S Shetye
- Department of Orthopaedic Surgery, University of Pennsylvania, United States of America
| | - Nancy Pleshko
- Department of Bioengineering, Temple University, United States of America
| | - Chamith S Rajapakse
- Department of Radiology, University of Pennsylvania, United States of America.,Department of Orthopaedic Surgery, University of Pennsylvania, United States of America
| |
Collapse
|
19
|
Pienkowski D, Wood CL, Malluche HH. Young's modulus and hardness of human trabecular bone with bisphosphonate treatment durations up to 20 years. Osteoporos Int 2019; 30:277-285. [PMID: 30488274 DOI: 10.1007/s00198-018-4760-x] [Citation(s) in RCA: 6] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 04/13/2018] [Accepted: 11/01/2018] [Indexed: 10/27/2022]
Abstract
UNLABELLED Bone modulus from patients with osteoporosis treated with bisphosphonates for 1 to 20 years was analyzed. Modulus increases during the first 6 years of treatment and remains unchanged thereafter. INTRODUCTION Bisphosphonates are widely used for treating osteoporosis, but the relationship between treatment duration and bone quality is unclear. Since material properties partially determine bone quality, the present study quantified the relationship between human bone modulus and hardness with bisphosphonate treatment duration. METHODS Iliac crest bone samples from a consecutive case series of 86 osteoporotic Caucasian women continuously treated with oral bisphosphonates for 1.1-20 years were histologically evaluated to assess bone turnover and then tested using nanoindentation. Young's modulus and hardness were measured and related to bisphosphonate treatment duration by statistical modeling. RESULTS All bone samples had low bone turnover. Statistical models showed that with increasing bisphosphonate treatment duration, modulus and hardness increased, peaked, and plateaued. These models used quadratic terms to model modulus increases from 1 to 6 years of bisphosphonate treatment and linear terms to model modulus plateaus from 6 to 20 years of treatment. The treatment duration at which the quadratic-linear transition (join point) occurred also depended upon trabecular location. Hardness increased and peaked at 12.4 years of treatment; it remained constant for the next 7.6 years of treatment and was insensitive to trabecular location. CONCLUSIONS Bone modulus increases with bisphosphonate treatment durations up to 6 years, no additional modulus increases occurred after 6 years of treatment. Although hardness increased, peaked at 12.4 years and remained constant for the next 7.6 years of BP treatment, the clinical relevance of hardness remains unclear.
Collapse
Affiliation(s)
- D Pienkowski
- F. Joseph Halcomb III, MD Department of Biomedical Engineering, University of Kentucky, Lexington, KY, USA
| | - C L Wood
- Department of Statistics, University of Kentucky, Lexington, KY, USA
| | - H H Malluche
- Division of Nephrology, Bone & Mineral Metabolism, Department of Medicine, University of Kentucky Chandler Medical Center, 800 Rose Street, MN-564, Lexington, KY, 40536-0298, USA.
| |
Collapse
|
20
|
Álvarez-Lloret P, Fernández JM, Molinuevo MS, Lino AB, Ferretti JL, Capozza RF, Cortizo AM, McCarthy AD. Multi-Scale Approach for the Evaluation of Bone Mineralization in Strontium Ranelate-Treated Diabetic Rats. Biol Trace Elem Res 2018; 186:457-466. [PMID: 29623650 DOI: 10.1007/s12011-018-1322-1] [Citation(s) in RCA: 6] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 11/23/2017] [Accepted: 03/21/2018] [Indexed: 11/27/2022]
Abstract
Long-term diabetes mellitus can induce osteopenia and osteoporosis, an increase in the incidence of low-stress fractures, and/or delayed fracture healing. Strontium ranelate (SrR) is a dual-action anti-osteoporotic agent whose use in individuals with diabetic osteopathy has not been adequately evaluated. In this study, we studied the effects of an oral treatment with SrR and/or experimental diabetes on bone composition and biomechanics. Young male Wistar rats (half non-diabetic, half with streptozotocin/nicotinamide-induced diabetes) were either untreated or orally administered 625 mg/kg/day of SrR for 6 weeks. After sacrifice, femora from all animals were evaluated by a multi-scale approach (X-ray diffraction, Fourier transform infrared spectroscopy, inductively coupled plasma optical-emission spectrometry, static histomorphometry, pQCT, and mechanical testing) to determine chemical, crystalline, and biomechanical properties. Untreated diabetic animals (versus untreated non-diabetic) showed a decrease in femoral mineral carbonate content, in cortical thickness and BMC, in trabecular osteocyte density, in maximum load supported at rupture and at yield point, and in overall toughness at mid-shaft. Treatment of diabetic animals with SrR further affected several parameters of bone (some already impaired by diabetes): crystallinity index (indicating less mature apatite crystals); trabecular area, BMC, and vBMD; maximum load at yield point; and structural elastic rigidity. However, SrR was also able to prevent the diabetes-induced decreases in trabecular osteocyte density (completely) and in bone ultimate strength at rupture (partially). Our results indicate that SrR treatment can partially but significantly prevent some bone structural mechanical properties as previously affected by diabetes, but not others (which may even be worsened).
Collapse
Affiliation(s)
- Pedro Álvarez-Lloret
- Departament of Geology, University of Oviedo, C/Jesús Arias de Velasco, s/n, 33005, Oviedo, Spain
| | - Juan Manuel Fernández
- Laboratorio de Investigaciones en Osteopatías y Metabolismo Mineral (LIOMM), Facultad de Ciencias Exactas, Universidad Nacional de La Plata, 47 y 115, 1900, La Plata, Argentina
| | - María Silvina Molinuevo
- Laboratorio de Investigaciones en Osteopatías y Metabolismo Mineral (LIOMM), Facultad de Ciencias Exactas, Universidad Nacional de La Plata, 47 y 115, 1900, La Plata, Argentina
| | - Agustina Berenice Lino
- Laboratorio de Investigaciones en Osteopatías y Metabolismo Mineral (LIOMM), Facultad de Ciencias Exactas, Universidad Nacional de La Plata, 47 y 115, 1900, La Plata, Argentina
| | - José Luis Ferretti
- Centro de Estudios del Metabolismo Fosfocálcico (CeMFoC), Facultad de Medicina, Universidad Nacional de Rosario, 2000, Rosario, Argentina
| | - Ricardo Francisco Capozza
- Centro de Estudios del Metabolismo Fosfocálcico (CeMFoC), Facultad de Medicina, Universidad Nacional de Rosario, 2000, Rosario, Argentina
| | - Ana María Cortizo
- Laboratorio de Investigaciones en Osteopatías y Metabolismo Mineral (LIOMM), Facultad de Ciencias Exactas, Universidad Nacional de La Plata, 47 y 115, 1900, La Plata, Argentina
| | - Antonio Desmond McCarthy
- Laboratorio de Investigaciones en Osteopatías y Metabolismo Mineral (LIOMM), Facultad de Ciencias Exactas, Universidad Nacional de La Plata, 47 y 115, 1900, La Plata, Argentina.
| |
Collapse
|
21
|
Dragomir-Daescu D, Rossman TL, Rezaei A, Carlson KD, Kallmes DF, Skinner JA, Khosla S, Amin S. Factors associated with proximal femur fracture determined in a large cadaveric cohort. Bone 2018; 116:196-202. [PMID: 30096469 PMCID: PMC6342454 DOI: 10.1016/j.bone.2018.08.005] [Citation(s) in RCA: 16] [Impact Index Per Article: 2.7] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 03/12/2018] [Revised: 08/02/2018] [Accepted: 08/07/2018] [Indexed: 12/16/2022]
Abstract
Many researchers have used cadaveric fracture tests to determine the relationship between proximal femur (hip) fracture strength and a multitude of possible explanatory variables, typically considered one or two at a time. These variables include subject-specific proximal femur variables such as femoral neck areal bone mineral density (aBMD), sex, age, and geometry, as well as physiological hip fracture event variables such as fall speed and angle of impact. However, to our knowledge, no study has included all of these variables simultaneously in the same experimental dataset. To address this gap, the present study simultaneously included all of these subject-specific and fracture event variables in multivariate models to understand their contributions to femoral strength and fracture type. The primary aim of this study was to determine not only whether each of these variables contributed to the prediction of femoral strength, but also to determine the relative importance of each variable in strength prediction. A secondary aim was to similarly characterize the importance of these variables for the prediction of fracture type. To accomplish these aims, we characterized 197 proximal femurs (covering a wide range of subject-specific variables) with DXA and CT scans, and then tested the femurs to fracture in a sideways fall on the hip configuration. Each femur was tested using one of three fall speed conditions and one of four angles of impact (bone orientations). During each test, we acquired measurements of relevant force and displacement data. We then reduced the test data to determine femoral strength, and we used post-fracture CT scans to classify the fracture type (e.g., trochanteric, cervical). Using these results, the explanatory variables were analyzed with mixed statistical models to explain variations in hip fracture strength and fracture type, respectively. Five explanatory variables were statistically significant in explaining the variability in femoral strength: aBMD, sex, age, fall speed, and neck-shaft angle (P ≤ 0.0135). These five variables, including significant interactions, explained 80% of the variability in hip fracture strength. Additionally, when only aBMD, sex, and age (P < 0.0001) were considered in the model, again including significant interactions, these three variables alone explained 79% of the variability in hip fracture strength. So while fall speed (P = 0.0135) and neck-shaft angle (P = 0.0041) were statistically significant, the inclusion of these variables did not appreciably improve the prediction of hip fracture strength compared to the model that considered only aBMD, sex and age. For the variables we included in this study, in the ranges we considered, our findings indicate that the clinically-available information of patient age, sex and aBMD are sufficient for femoral strength assessment. These findings also suggest that there is little value in the extra effort required to characterize the effect of femoral geometry on strength, or to account for the probabilistic nature of fall-related factors such as fall speed and angle of impact. For fracture type, the only explanatory variable found to be significant was aBMD (P ≤ 0.0099). We found that the odds of having intertrochanteric fractures increased by 47% when aBMD decreased by one standard deviation (0.2 g/cm2).
Collapse
Affiliation(s)
- Dan Dragomir-Daescu
- Department of Physiology and Biomedical Engineering, Mayo Clinic, United States.
| | | | - Asghar Rezaei
- Department of Physiology and Biomedical Engineering, Mayo Clinic, United States
| | - Kent D Carlson
- Department of Physiology and Biomedical Engineering, Mayo Clinic, United States
| | | | | | - Sundeep Khosla
- Robert and Arlene Kogod Center on Aging and Endocrine Research Unit, Mayo Clinic, United States
| | - Shreyasee Amin
- Division of Rheumatology, Mayo Clinic, United States; Division of Epidemiology, Department of Health Sciences Research, Mayo Clinic, United States
| |
Collapse
|
22
|
Gargiulo P, Edmunds KJ, Gíslason MK, Latour C, Hermannsson Þ, Esposito L, Bifulco P, Cesarelli M, Fraldi M, Cristofolini L, Jónsson H. Patient-specific mobility assessment to monitor recovery after total hip arthroplasty. Proc Inst Mech Eng H 2018; 232:1048-1059. [PMID: 30191747 DOI: 10.1177/0954411918797971] [Citation(s) in RCA: 8] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/22/2022]
Abstract
Total hip arthroplasty is a ubiquitously successful orthopedic surgical procedure, whose prevalence is rising worldwide. While many investigations focus on characterizing periprosthetic pathophysiology, the objective of our research is to develop and describe multi-metric assemblies as a first step toward creating a patient-specific mobility index that rehabilitators and orthopedic surgeons can utilize for prescribing their respective procedures. In total, 48 total hip arthroplasty patients (both cemented and uncemented) undergoing unilateral, primary surgery went through computed tomographic scans and gait analysis measurements both before and 1 year following their surgery. Altogether, the reported quantitative metrics include 11 spatial and temporal gait parameters, muscle density, and electromyography signals from the rectus femoris, vastus lateralis, and vastus medialis, and bone mineral density values from bioimage analysis around the implant stem. We found that measured parameters from a subgroup were sensitive to changes observed during patient recovery, implicating the predictive sensitivity of these patient conditions. Most post-operative gait parameters changed significantly, while electromyography data indicated few significant differences. Moreover, results from bioimage analyses indicate a general reduction of periprosthetic bone mineral density after 1 year, in association with increasing density of the quadriceps muscles. Furthermore, this work identifies which quantitative metrics undergo the greatest variation after total hip arthroplasty and demonstrates the clinical feasibility of a multimodal approach to mobility assessment that may ultimately support decision-making for post-surgical rehabilitation protocols.
Collapse
Affiliation(s)
- Paolo Gargiulo
- 1 Institute for Biomedical and Neural Engineering, Reykjavík University, Reykjavík, Iceland.,2 Department of Science, Landspítali University Hospital, Reykjavík, Iceland
| | - Kyle Joseph Edmunds
- 1 Institute for Biomedical and Neural Engineering, Reykjavík University, Reykjavík, Iceland
| | - Magnús K Gíslason
- 1 Institute for Biomedical and Neural Engineering, Reykjavík University, Reykjavík, Iceland
| | - Chase Latour
- 3 Washington University in St. Louis, St. Louis, MO, USA
| | - Þröstur Hermannsson
- 1 Institute for Biomedical and Neural Engineering, Reykjavík University, Reykjavík, Iceland
| | - Luca Esposito
- 4 Department of Structures for Engineering and Architecture, University of Naples Federico II, Naples, Italy
| | - Paolo Bifulco
- 5 Department of Electrical Engineering and Information Technologies, University of Naples Federico II, Naples, Italy
| | - Mario Cesarelli
- 5 Department of Electrical Engineering and Information Technologies, University of Naples Federico II, Naples, Italy
| | - Massimiliano Fraldi
- 4 Department of Structures for Engineering and Architecture, University of Naples Federico II, Naples, Italy.,6 Interdisciplinary Research Centre for Biomaterials, University of Naples Federico II, Naples, Italy
| | - Luca Cristofolini
- 7 Department of Industrial Engineering, University of Bologna, Bologna, Italy
| | - Halldór Jónsson
- 8 Faculty of Medicine, University of Iceland, Reykjavík, Iceland.,9 Orthopedic Clinic, Landspítali University Hospital, Reykjavík, Iceland
| |
Collapse
|
23
|
Wu JZ, Liu PC, Liu R, Cai M. Icariin Restores Bone Structure and Strength in a Rat Model of Chronic High-Dose Alcohol-Induced Osteopenia. Cell Physiol Biochem 2018; 46:1727-1736. [PMID: 29698972 DOI: 10.1159/000489248] [Citation(s) in RCA: 12] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/21/2017] [Accepted: 03/13/2018] [Indexed: 11/19/2022] Open
Abstract
BACKGROUND/AIMS Chronic alcohol abuse is an important risk factor for osteopenia. However, few studies have focused on the efficacy and mechanism of action of icariin on alcohol-induced osteopenia. The aim of this study was to investigate the efficacy and underlying mechanism of action of icariin in the treatment of chronic high-dose alcohol-induced osteopenia in a rat model. METHODS Thirty-six adult male Sprague-Dawley rats were randomly divided into four groups: sham, alcohol, and low-dose and high-dose icariin groups. Bone volume fraction (BV/TV), bone mineral density (BMD), bone biomechanical properties, and bone morphology were assessed after 16 weeks. Reverse-transcription PCR was used to detect mRNA expression levels of alkaline phosphatase (ALP), collagen type I (Col I), osteocalcin (OC), runt-related transcription factor 2 (Runx2), bone morphogenetic protein-2 (BMP-2), and osteoprotegerin (OPG). RESULTS Bone metabolic markers and biomechanical properties in the alcohol group were decreased significantly compared with the sham group. BV/TV, BMD, mineral apposition rate (MAR), percent trabecular area (%Tb.Ar), and bone biomechanical properties were elevated in the low-dose and high-dose icariin groups relative to the alcohol group. ALP, Col I, OC, Runx2, BMP-2, and OPG mRNA levels in the icariin group were significantly elevated in comparison with the alcohol group. CONCLUSION Icariin can prevent overall progression of chronic high-dose alcohol-induced osteopenia in a rat model, in a dose-dependent manner. Icariin promotes bone formation and inhibits bone loss, and effectively restores bone structure and strength in chronic high-dose alcohol-induced osteopenic rats. Bone metabolism reversal is evidenced by increased BV/TV, BMD, MAR, %Tb.Ar, and biomechanical properties and elevated ALP, Col I, OC, Runx2, BMP-2, and OPG mRNA levels.
Collapse
Affiliation(s)
- Jie-Zhou Wu
- Department of Orthopedics, Shanghai Tenth People's Hospital, School of Medicine, Tongji University, Shanghai, China
| | - Peng-Cheng Liu
- Department of Orthopedics, Shanghai Tenth People's Hospital, School of Medicine, Tongji University, Shanghai, China
| | - Run Liu
- Department of Orthopedics, Affiliated Hospital of Chengdu University, Chengdu, China
| | - Ming Cai
- Department of Orthopedics, Shanghai Tenth People's Hospital, School of Medicine, Tongji University, Shanghai, China
| |
Collapse
|
24
|
Gardinier JD, Rostami N, Juliano L, Zhang C. Bone adaptation in response to treadmill exercise in young and adult mice. Bone Rep 2018; 8:29-37. [PMID: 29379848 PMCID: PMC5787623 DOI: 10.1016/j.bonr.2018.01.003] [Citation(s) in RCA: 34] [Impact Index Per Article: 5.7] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 09/27/2017] [Revised: 12/20/2017] [Accepted: 01/11/2018] [Indexed: 11/30/2022] Open
Abstract
Exercise is a key determinate of fracture risk and provides a clinical means to promote bone formation. However, the efficacy of exercise to increase bone mass declines with age. The purpose of this study was to identify age-related differences in the anabolic response to exercise at the cellular and tissue level. To this end, young (8-weeks of age) and adult (36-weeks of age) male mice were subjected to a moderate exercise regimen of running on a treadmill. As a result, exercise had a significant effect on PTHrP and SOST gene expression during the first week that was dependent upon age. In particular, young mice displayed an increase in PTHrP expression and decrease in SOST expression, both of which remained unaffected by exercise in the adult mice. After 5-weeks of exercise, a significant decrease in the percentage of osteocytes expressing sclerostin at the protein level was found in young mice, but not adult mice. Mechanical testing of the tibia found exercise to have a significant influence on tissue-level mechanical properties, specifically ultimate-stress and modulus that was dependent on age. Adult mice in particular experienced a significant decrease in modulus despite an increase in cortical area and cortical thickness compared to sedentary controls. Altogether, this study demonstrates a shift in the cellular response to exercise with age, and that gains in bone mass at the adult stage fail to improve bone strength.
Collapse
Affiliation(s)
- Joseph D. Gardinier
- Bone and Joint Center, Henry Ford Hospital, Detroit, MI 48202, USA
- Corresponding author at: Bone and Joint Center, Henry Ford Health System, 6135 Woodward Avenue, Detroit, MI 48202, USA.
| | - Niloufar Rostami
- Bone and Joint Center, Henry Ford Hospital, Detroit, MI 48202, USA
| | | | - Chunbin Zhang
- Bone and Joint Center, Henry Ford Hospital, Detroit, MI 48202, USA
| |
Collapse
|
25
|
Pujari-Palmer M, Robo C, Persson C, Procter P, Engqvist H. Influence of cement compressive strength and porosity on augmentation performance in a model of orthopedic screw pull-out. J Mech Behav Biomed Mater 2017; 77:624-633. [PMID: 29100205 DOI: 10.1016/j.jmbbm.2017.10.016] [Citation(s) in RCA: 15] [Impact Index Per Article: 2.1] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/01/2017] [Revised: 10/09/2017] [Accepted: 10/10/2017] [Indexed: 12/20/2022]
Abstract
Disease and injuries that affect the skeletal system may require surgical intervention and internal fixation, i.e. orthopedic plate and screw insertion, to stabilize the injury and facilitate tissue repair. If the surrounding bone quality is poor the screws may migrate, or the bone may fail, resulting in fixation failure. While numerous studies have shown that cement augmentation of the interface between bone and implant can increase screw pull-out force, the physical properties of cement that influence pull-out force have not been investigated. The present study sought to determine how the physical properties of high strength calcium phosphate cements (hsCPCs, specifically dicalcium phosphate) affected the corresponding orthopedic screw pull-out force in urethane foam models of "healthy" and "osteoporotic" synthetic bone (Sawbones). In the simplest model, where only the bond strength between screw thread and cement (without Sawbone) was tested, the correlation between pull-out force and cement compressive strength (R2 = 0.79) was weaker than correlation with total cement porosity (R2 = 0.89). In open pore Sawbone that mimics "healthy" cancellous bone density the stronger cements produced higher pull-out force (50-60% increase). High strength, low porosity cements also produced higher pull-out forces (50-190% increase) in "healthy" Sawbones with cortical fixation if the failure strength of the cortical material was similar to, or greater than (a metal shell), actual cortical bone. This result is of particular clinical relevance where fixation with a metal plate implant is indicated, as the nearby metal can simulate a thicker cortical shell, thereby increasing the pull-out force of screws augmented with stronger cements. The improvement in pull-out force was apparent even at low augmentation volumes of 0.5mL (50% increase), which suggest that in clinical situations where augmentation volume is limited the stronger, lower porosity calcium phosphate cement (CPC) may still produce a significant improvement in screw pull-out force. When the correlation strength of all the tested models were compared both cement porosity and compressive strength accurately predicted pull-out force (R2=1.00, R2=0.808), though prediction accuracy depended upon the strength of the material surrounding the Sawbone. The correlations strength was low for bone with no, or weak, cortical fixation (R2=0.56, 0.36). Higher strength and lower porosity CPCs also produced greater pull-out force (1-1.5kN) than commercial CPC (0.2-0.5kN), but lower pull-out force than PMMA (2-3kN). The results of this study suggest that the likelihood of screw fixation failure may be reduced by selecting calcium phosphate cements with lower porosity and higher compressive strength, in patients with healthy bone mineral density and/or sufficient cortical thickness. This is of particular clinical relevance when fixation with metal plates is indicated, or where the augmentation volume is limited.
Collapse
Affiliation(s)
- Michael Pujari-Palmer
- Materials in Medicine, Div. of Applied Materials Science, Dept. of Engineering Sciences, Uppsala University, Box 534, SE-751 21 Uppsala, Sweden
| | - Celine Robo
- Materials in Medicine, Div. of Applied Materials Science, Dept. of Engineering Sciences, Uppsala University, Box 534, SE-751 21 Uppsala, Sweden
| | - Cecilia Persson
- Materials in Medicine, Div. of Applied Materials Science, Dept. of Engineering Sciences, Uppsala University, Box 534, SE-751 21 Uppsala, Sweden
| | - Philip Procter
- Materials in Medicine, Div. of Applied Materials Science, Dept. of Engineering Sciences, Uppsala University, Box 534, SE-751 21 Uppsala, Sweden
| | - Håkan Engqvist
- Materials in Medicine, Div. of Applied Materials Science, Dept. of Engineering Sciences, Uppsala University, Box 534, SE-751 21 Uppsala, Sweden.
| |
Collapse
|
26
|
Rezaei A, Giambini H, Rossman T, Carlson KD, Yaszemski MJ, Lu L, Dragomir-Daescu D. Are DXA/aBMD and QCT/FEA Stiffness and Strength Estimates Sensitive to Sex and Age? Ann Biomed Eng 2017; 45:2847-2856. [PMID: 28940110 DOI: 10.1007/s10439-017-1914-5] [Citation(s) in RCA: 9] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/06/2017] [Accepted: 08/31/2017] [Indexed: 10/18/2022]
Abstract
Dual X-ray absorptiometry (DXA) measures areal bone mineral density (aBMD) by simplifying a complex 3D bone structure to a 2D projection and is not equally effective for explaining fracture strength in women and men. Unlike DXA, subject-specific quantitative computed tomography-based finite element analysis (QCT/FEA) estimates fracture strength using 3D bone mineral distribution and geometry. By using experimentally-measured femoral stiffness and strength from a one hundred sample cadaveric cohort that included variations in sex and age, we wanted to determine if QCT/FEA estimates were able to better predict the experimental variations than DXA/aBMD. For each femur, DXA/aBMD was assessed and a QCT/FEA model was developed to estimate femoral stiffness and strength. Then, the femur was mechanically tested to fracture in a sideways fall on the hip position to measure stiffness and strength. DXA/aBMD and QCT/FEA estimates were compared for their sensitivity to sex and age with multivariate statistical analyses. When comparing the measured data with DXA/aBMD predictions, both age and sex were significant (p ≤ 0.0398) for both femoral stiffness and strength. However, QCT/FEA predictions of stiffness and strength showed sex was insignificant (p ≥ 0.23). Age was still significant (p ≤ 0.0072). These results indicate that QCT/FEA, unlike DXA/aBMD, accounted for bone differences due to sex.
Collapse
Affiliation(s)
- Asghar Rezaei
- Department of Physiology and Biomedical Engineering, Mayo Clinic, 200 First Street, S.W., Rochester, MN, 55905, USA
| | - Hugo Giambini
- Department of Orthopedic Surgery, Mayo Clinic, Rochester, MN, USA
| | | | - Kent D Carlson
- Department of Physiology and Biomedical Engineering, Mayo Clinic, 200 First Street, S.W., Rochester, MN, 55905, USA
| | | | - Lichun Lu
- Department of Physiology and Biomedical Engineering, Mayo Clinic, 200 First Street, S.W., Rochester, MN, 55905, USA
| | - Dan Dragomir-Daescu
- Department of Physiology and Biomedical Engineering, Mayo Clinic, 200 First Street, S.W., Rochester, MN, 55905, USA.
| |
Collapse
|
27
|
Bozzini C, Viscor G, Kristjánsson JCR, Picasso E, Champin G, Alippi RM, Bozzini CE. Increased intrinsic stiffness and mineralization in femurs of adult rats after high intensity treadmill running training. Biomed Mater Eng 2017; 28:431-441. [PMID: 28869430 DOI: 10.3233/bme-171684] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/15/2022]
Abstract
BACKGROUND Physical activity plays a tremendous role in determining bone mechanical behavior, which is superimposed to gravidity. OBJECTIVE Compare the geometric and material responses of the rat femur to a high intensity treadmill running training of a relatively short duration, as assessed by 3-point mechanical test. METHODS Mature male rats (180.0 ± 30 g) were assigned (7 rats/group) to no exercise (NE) or treadmill exercise (EX). After a preconditioning period, the running speed was set at 45 cm.seg-1 during 2 wks, frequency 5 d/wk, 2-hour sessions/day. Body weight and weight of the crural quadriceps were registered at euthanasia. The right femur was mechanically tested through 3-point bending. The left femur was ashed to estimate bone mineral content. Geometric and material bone properties were estimated directly or calculated by appropriate equations. RESULTS 1) Final body weight was 14% reduced in EX rats, while the crural quadriceps was 47% increased. Yield and fracture loads, and structural stiffness were significantly higher in the EX rats, as were the apparent elastic modulus, the bone mineral content and the degree of mineralization. Geometric properties were not affected. CONCLUSIONS High intensity treadmill running training increases bone strength and stiffness by increasing material stiffness and mineralization, without affecting geometric bone parameters.
Collapse
Affiliation(s)
- Clarisa Bozzini
- Cátedra de Fisiología, Facultad de Odontología, Universidad de Buenos Aires, Argentina. E-mail:
| | - Ginés Viscor
- Departament de Fisiología i Immunología, Universitat de Barcelona, España
| | | | - Emilio Picasso
- Facultad de Ingeniería, Universidad de Buenos Aires, Argentina
| | - Graciela Champin
- Cátedra de Fisiología, Facultad de Odontología, Universidad de Buenos Aires, Argentina. E-mail:
| | - Rosa M Alippi
- Cátedra de Fisiología, Facultad de Odontología, Universidad de Buenos Aires, Argentina. E-mail:
| | - Carlos E Bozzini
- Cátedra de Fisiología, Facultad de Odontología, Universidad de Buenos Aires, Argentina. E-mail:
| |
Collapse
|
28
|
Lejonklou MH, Christiansen S, Örberg J, Shen L, Larsson S, Boberg J, Hass U, Lind PM. Low-dose developmental exposure to bisphenol A alters the femoral bone geometry in wistar rats. Chemosphere 2016; 164:339-346. [PMID: 27592323 DOI: 10.1016/j.chemosphere.2016.08.114] [Citation(s) in RCA: 18] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 07/01/2016] [Revised: 08/22/2016] [Accepted: 08/23/2016] [Indexed: 06/06/2023]
Abstract
BACKGROUND Bisphenol A (BPA) is a chemical produced in large volumes for use in manufacturing of consumer products and industrial applications, and an endocrine disruptor known to affect several hormonal systems. Bone produces hormones and is additionally a sensitive hormone target tissue, and is thus potentially sensitive to low doses of endocrine disruptors such as BPA, especially during development. METHODS 110 pregnant Wistar rats were gavaged with 0; 25 μg; 250 μg; 5000 μg or 50,000 μg BPA/kg bodyweight (bw)/day from gestational day 7 until weaning at postnatal day 22. The three-month-old offspring were sacrificed and right femurs collected for length measurements, geometrical measurements by peripheral quantitative computed tomography (pQCT), as well as for analyses of biomechanical properties using the three-point-bending method. RESULTS The femur was elongated in female offspring of dams exposed to 25 or 5000 μg BPA/kg bw/day (1.8% and 2.1%, respectively), and increased cortical thickness (4.7%) was observed in male offspring of dams exposed to 25 μg BPA/kg bw/day, compared to controls (p < 0.005). The biomechanical properties of the bone were not significantly altered. CONCLUSIONS In utero and lactational exposure to the lowest BPA dose used in this study altered femoral geometry in both male and female offspring. This was observed at 25 μg BPA/kg bw/day, a dose lower than the Human Equivalent Dose (HED) applied by EFSA to set a temporary TDI (609 μg BPA/kg bw/day), and far lower than the No-Observed-Adverse-Effect-Level (NOAEL) (5000 μg BPA/kg bw/day) on which the US FDA TDI is based.
Collapse
Affiliation(s)
- M H Lejonklou
- Department of Medical Sciences, Occupational and Environmental Medicine, Box 256, Uppsala University, SE-751 85 Uppsala, Sweden.
| | - S Christiansen
- Division of Diet, Disease Prevention and Toxicology, Technical University of Denmark, Mørkhøj Bygade 19, DK-2860 Søborg, Denmark
| | - J Örberg
- Department of Environmental Toxicology, Evolutionary Biology Centre, Box 256, Uppsala University, SE-75105 Uppsala, Sweden
| | - L Shen
- Department of Medical Sciences, Occupational and Environmental Medicine, Box 256, Uppsala University, SE-751 85 Uppsala, Sweden
| | - S Larsson
- Department of Surgical Sciences, Section of Orthopedics, Box 256, Uppsala University, SE-75185 Uppsala, Sweden
| | - J Boberg
- Division of Diet, Disease Prevention and Toxicology, Technical University of Denmark, Mørkhøj Bygade 19, DK-2860 Søborg, Denmark
| | - U Hass
- Division of Diet, Disease Prevention and Toxicology, Technical University of Denmark, Mørkhøj Bygade 19, DK-2860 Søborg, Denmark
| | - P M Lind
- Department of Medical Sciences, Occupational and Environmental Medicine, Box 256, Uppsala University, SE-751 85 Uppsala, Sweden
| |
Collapse
|
29
|
Cointry GR, Nocciolino L, Ireland A, Hall NM, Kriechbaumer A, Ferretti JL, Rittweger J, Capozza RF. Structural differences in cortical shell properties between upper and lower human fibula as described by pQCT serial scans. A biomechanical interpretation. Bone 2016; 90:185-94. [PMID: 27302664 DOI: 10.1016/j.bone.2016.06.007] [Citation(s) in RCA: 13] [Impact Index Per Article: 1.6] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 10/25/2015] [Revised: 06/06/2016] [Accepted: 06/10/2016] [Indexed: 12/01/2022]
Abstract
This study describes the structural features of fibula cortical shell as allowed by serial pQCT scans in 10/10 healthy men and women aged 20-40years. Indicators of cortical mass (mineral content -BMC-, cross-sectional area -CSA-), mineralization (volumetric BMD, vBMD), design (perimeters, thickness, moments of inertia -MIs-) and strength (Bone Strength Indices, BSIs; polar Strength-Strain Index, pSSI) were determined. All cross-sectional shapes and geometrical or strength indicators suggested a sequence of five different regions along the bone, which would be successively adapted to 1. transmit loads from the articular surface to the cortical shell (near the proximal tibia-fibular joint), 2. favor lateral bending (central part of upper half), 3. resist lateral bending (mid-diaphysis), 4. favor lateral bending again (central part of the lower half), and 5. resist bending/torsion (distal end). Cortical BMC and the cortical/total CSA ratio were higher at the midshaft than at both bone ends (p<0.001). However, all MIs, BSIs and pSSI values and the endocortical perimeter/cortical CSA ratio (indicator of the mechanostat's ability to re-distribute the available cortical mass) showed a "W-shaped" distribution along the bone, with maximums at the mid-shaft and at both bone's ends (site effect, p<0.001). The correlation coefficient (r) of the relationship between MIs (y) and cortical vBMD (x) at each bone site ("distribution/quality" curve that describes the efficiency of distribution of the cortical tissue as a function of the local tissue stiffness) was higher at proximal than distal bone regions (p<0.001). The results from the study suggest that human fibula is primarily adapted to resist bending and torsion rather than compression stresses, and that fibula's bending strength is lower at the center of its proximal and distal halves and higher at the mid-shaft and at both bone's ends. This would favor, proximally, the elastic absorption of energy by the attached muscles that rotate or evert the foot, and distally, the widening of the heel joint and the resistance to excessive lateral bending. Results also suggest that biomechanical control of structural stiffness differs between proximal and distal fibula.
Collapse
Affiliation(s)
- Gustavo R Cointry
- Center of P-Ca Metabolism Studies (CEMFoC), National University of Rosario, Rosario, Argentina
| | - Laura Nocciolino
- Center of P-Ca Metabolism Studies (CEMFoC), National University of Rosario, Rosario, Argentina
| | - Alex Ireland
- School of Healthcare Science, Manchester Metropolitan University, Manchester, UK.
| | - Nicolas M Hall
- Division of Space Physiology, Institute of Aerospace Medicine, German Aerospace Center, Cologne, Germany
| | - Andreas Kriechbaumer
- Division of Space Physiology, Institute of Aerospace Medicine, German Aerospace Center, Cologne, Germany
| | - José L Ferretti
- Center of P-Ca Metabolism Studies (CEMFoC), National University of Rosario, Rosario, Argentina
| | - Jörn Rittweger
- Division of Space Physiology, Institute of Aerospace Medicine, German Aerospace Center, Cologne, Germany
| | - Ricardo F Capozza
- Center of P-Ca Metabolism Studies (CEMFoC), National University of Rosario, Rosario, Argentina
| |
Collapse
|
30
|
Oestreich AK, Garcia MR, Yao X, Pfeiffer FM, Nobakhti S, Shefelbine SJ, Wang Y, Brodeur AC, Phillips CL. Characterization of the MPS I-H knock-in mouse reveals increased femoral biomechanical integrity with compromised material strength and altered bone geometry. Mol Genet Metab Rep 2015. [PMID: 28649535 PMCID: PMC5471398 DOI: 10.1016/j.ymgmr.2015.08.004] [Citation(s) in RCA: 6] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/30/2022] Open
Abstract
Mucopolysaccharidosis type I (MPS I), is an autosomal recessive lysosomal storage disorder caused by a deficiency in the α-L-iduronidase enzyme, resulting in decreased enzymatic activity and accumulation of glycosaminoglycans. The disorder phenotypically manifests with increased urine glycosaminoglycan excretion, facial dysmorphology, neuropathology, cardiac manifestations, and bone deformities. While the development of new treatment strategies have shown promise in attenuating many symptoms associated with the disorder, the bone phenotype remains unresponsive. The aim of this study was to investigate and further characterize the skeletal manifestations of the Idua-W392X knock-in mouse model, which carries a nonsense mutation corresponding to the IDUA-W402X mutation found in Hurler syndrome (MPS I-H) patients. μCT analysis of the microarchitecture demonstrated increased cortical thickness, trabecular number, and trabecular connectivity along with decreased trabecular separation in the tibiae of female homozygous Idua-W392X knock-in (IDUA−/−) mice, and increased cortical thickness in male IDUA−/− tibiae. Cortical density, as determined by μCT, and bone mineral density distribution, as determined by quantitative backscattered microscopy, were equivalent in IDUA−/− and wildtype (Wt) bone. However, tibial porosity was increased in IDUA−/− cortical bone. Raman spectroscopy results indicated that tibiae from female IDUA−/− had decreased phosphate to matrix ratios and increased carbonate to phosphate ratios compared to Wt female tibiae, whereas these ratios remained equivalent in male IDUA−/− and Wt tibiae. Femora demonstrated altered geometry and upon torsional loading to failure analysis, female IDUA−/− mouse femora exhibited increased torsional ultimate strength, with a decrease in material strength relative to Wt littermates. Taken together, these findings suggest that the IDUA−/− mutation results in increased bone torsional strength by altering the overall bone geometry and the microarchitecture which may be a compensatory response to increased porosity, reduced bone tensile strength and altered physiochemical composition.
Collapse
Key Words
- BMD, bone mineral density
- BMDD, bone mineral density distribution
- BV/TV, bone volume/total volume
- Bone biomechanics
- FWHM, full width at half maximum
- G, shear modulus of elasticity
- GAGs, glycosaminoglycans
- IDUA, α-L-iduronidase
- Idua-W392X
- Ks, stiffness
- MPS I, mucopolysaccharidosis type I
- Mucopolysaccharidosis type I
- Raman spectroscopy
- SMI, structure model index
- Su, tensile strength
- Tmax, torsional ultimate strength
- U, energy to failure
- α-L-iduronidase
- μCT, microcomputed tomography
Collapse
Affiliation(s)
- Arin K Oestreich
- Department of Biological Sciences, University of Missouri, Columbia, MO 65211, United States
| | - Mekka R Garcia
- Department of Biochemistry, University of Missouri, Columbia, MO 65211, United States
| | - Xiaomei Yao
- Department of Oral and Craniofacial Sciences, School of Dentistry, University of Missouri-Kansas City, Kansas City, MO 64108, United States
| | - Ferris M Pfeiffer
- Department of Orthopaedic Surgery and Bioengineering, University of Missouri, Columbia, MO 65211, United States
| | - Sabah Nobakhti
- Department of Mechanical and Industrial Engineering, Northeastern University, Boston, MA 02115, United States
| | - Sandra J Shefelbine
- Department of Mechanical and Industrial Engineering, Northeastern University, Boston, MA 02115, United States
| | - Yong Wang
- Department of Oral and Craniofacial Sciences, School of Dentistry, University of Missouri-Kansas City, Kansas City, MO 64108, United States
| | - Amanda C Brodeur
- Department of Biomedical Sciences, Missouri State University, Springfield, MO 65804, United States
| | - Charlotte L Phillips
- Department of Biochemistry, University of Missouri, Columbia, MO 65211, United States.,Department of Child Health, University of Missouri, Columbia, MO 65211, United States
| |
Collapse
|
31
|
Abstract
Extracorporeal irradiation of an excised tumour-bearing segment of bone followed by its re-implantation is a technique used in bone sarcoma surgery for limb salvage when the bone is of reasonable quality. There is no agreement among previous studies about the dose of irradiation to be given: up to 300 Gy have been used. We investigated the influence of extracorporeal irradiation on the elastic and viscoelastic properties of bone. Bone was harvested from mature cattle and subdivided into 13 groups: 12 were exposed to increasing levels of irradiation: one was not and was used as a control. The specimens, once irradiated, underwent mechanical testing in saline at 37°C. The mechanical properties of each group, including Young's modulus, storage modulus and loss modulus, were determined experimentally and compared with the control group. There were insignificant changes in all of these mechanical properties with an increasing level of irradiation. We conclude that the overall mechanical effect of high levels of extracorporeal irradiation (300 Gy) on bone is negligible. Consequently the dose can be maximised to reduce the risk of local tumour recurrence.
Collapse
Affiliation(s)
- S Gupta
- Glasgow Royal Infirmary, Castle Street, Glasgow, G0 4SF, UK
| | - D Cafferky
- University of Strathclyde, 106 Rottenrow East, Glasgow, G4 0NW, UK
| | - F Cowie
- Beatson Oncology Centre, 1053 Great Western Road, Glasgow, G11 0YN, UK
| | - P Riches
- University of Strathclyde, 106 Rottenrow East, Glasgow, G4 0NW, UK
| | - A Mahendra
- Glasgow Royal Infirmary, Castle Street, Glasgow, G0 4SF, UK
| |
Collapse
|
32
|
Schileo E, Balistreri L, Grassi L, Cristofolini L, Taddei F. To what extent can linear finite element models of human femora predict failure under stance and fall loading configurations? J Biomech 2014; 47:3531-8. [PMID: 25261321 DOI: 10.1016/j.jbiomech.2014.08.024] [Citation(s) in RCA: 108] [Impact Index Per Article: 10.8] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/28/2014] [Revised: 08/08/2014] [Accepted: 08/31/2014] [Indexed: 11/29/2022]
Abstract
Proximal femur strength estimates from computed tomography (CT)-based finite element (FE) models are finding clinical application. Published models reached a high in-vitro accuracy, yet many of them rely on nonlinear methodologies or internal best-fitting of parameters. The aim of the present study is to verify to what extent a linear FE modelling procedure, fully based on independently determined parameters, can predict the failure characteristics of the proximal femur in stance and sideways fall loading configurations. Fourteen fresh-frozen cadaver femora were CT-scanned. Seven femora were tested to failure in stance loading conditions, and seven in fall. Fracture was monitored with high-speed videos. Linear FE models were built from CT images according to a procedure already validated in the prediction of strains. An asymmetric maximum principal strain criterion (0.73% tensile, 1.04% compressive limit) was used to define a node-based risk factor (RF). FE-predicted failure load, mode (tensile/compressive) and location were determined from the first node reaching RF=1. FE-predicted and measured failure loads were highly correlated (R(2)=0.89, SEE=814N). In all specimens, FE models correctly identified the failure mode (tensile in stance, compressive in fall) and the femoral region where fracture started (supero-lateral neck aspect). The location of failure onset was accurately predicted in eight specimens. In summary, a simple FE model, adaptable in the future to multiple loads (e.g. including muscles), was highly correlated with experimental failure in two loading conditions on specimens ranging from normal to osteoporotic. Thus, it can be suitable for use in clinical studies.
Collapse
Affiliation(s)
- Enrico Schileo
- Laboratorio di Bioingegneria Computazionale, Istituto Ortopedico Rizzoli, Via di Barbiano, 1/10, 40136 Bologna, Italy.
| | - Luca Balistreri
- Laboratorio di Tecnologia Medica, Istituto Ortopedico Rizzoli, Bologna, Italy
| | - Lorenzo Grassi
- Laboratorio di Tecnologia Medica, Istituto Ortopedico Rizzoli, Bologna, Italy
| | - Luca Cristofolini
- Department of Industrial Engineering, University of Bologna, Bologna, Italy
| | - Fulvia Taddei
- Laboratorio di Tecnologia Medica, Istituto Ortopedico Rizzoli, Bologna, Italy
| |
Collapse
|