1
|
Higinbotham SE, Ali AA, Liu XC, Blackwood CA, Rullkoetter PJ, Blackwood CB, Shelburne KB. Determinants of pivot kinematics in posterior stabilized total knee arthroplasty. Clin Biomech (Bristol, Avon) 2024; 120:106350. [PMID: 39317133 DOI: 10.1016/j.clinbiomech.2024.106350] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 06/18/2024] [Revised: 08/28/2024] [Accepted: 09/16/2024] [Indexed: 09/26/2024]
Abstract
BACKGROUND Restoring medial knee pivot kinematics post-total knee arthroplasty is widely recognized to enhance patient satisfaction. Our study investigates the kinematics of patients who received posterior stabilized implants via robotic-arm assisted surgery, specifically analyzing effects of implant alignment and soft tissue balance on pivot location. METHODS Twelve high-functioning patients with unilateral posterior stabilizing knee implants underwent CT-guided robotic-arm assisted surgery. We then evaluated their knee kinematics using stereo radiography during gait, stair descent, lunge, seated knee extension and leg press. Femoral low-point condylar kinematics were used to calculate the transverse center of rotation, or pivot, using principal component analysis. Linear mixed effects regression was used to identify surgical parameters that influence pivot location across a flexion range. FINDINGS Across all five activities a central pivot pattern emerged as the primary pivot location (40 %) followed by medial (25 %), no pivot (22 %) and lateral (14 %). Tibial medial resection depth and Tibial implant flexion-extension placement were significantly associated with shifting the pivot location laterally prior to cam-post engagement. Femoral implant external-internal implant placement, and medial compartment laxity in extension were significantly associated with shifting the pivot location laterally during the cam-post engagement, while femoral distal-lateral resection depth was associated with a medial shift. INTERPRETATION Central and medial pivot locations are predominant in patients with posterior stabilized total knee arthroplasty, facilitated by robotic-arm assisted surgery. Despite significant associations between surgical parameters such as tibial medial resection depth and lateral compartment laxity with medial pivot, these variables explained a small portion of the variability in pivot location. This suggests that while surgical precision influences pivot kinematics, individual patient factors may play a more critical role, suggesting a need for further research into patient-specific biomechanics to optimize post-surgical outcomes.
Collapse
Affiliation(s)
- Sean E Higinbotham
- Center for Orthopaedic Biomechanics, University of Denver, Denver, CO, USA
| | | | | | | | - Paul J Rullkoetter
- Center for Orthopaedic Biomechanics, University of Denver, Denver, CO, USA
| | | | - Kevin B Shelburne
- Center for Orthopaedic Biomechanics, University of Denver, Denver, CO, USA.
| |
Collapse
|
2
|
Sanghavi SA, Nedopil AJ, Howell SM, Hull ML. An Insert Goniometer Can Help Select the Optimal Insert Thickness When Performing Kinematically Aligned Total Knee Arthroplasty with a Medial 1:1 Ball-in-Socket and Lateral Flat Surface Insert and Posterior Cruciate Ligament Retention. Bioengineering (Basel) 2024; 11:910. [PMID: 39329652 PMCID: PMC11444139 DOI: 10.3390/bioengineering11090910] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/23/2024] [Revised: 08/29/2024] [Accepted: 09/07/2024] [Indexed: 09/28/2024] Open
Abstract
Current surgical practices in total knee arthroplasty (TKA) have advanced and include significant changes and improvements in alignment philosophies, femorotibial implant conformities, and ligament management to replicate in vivo knee kinematics. While corrective measures have emphasized sagittal plane alignment to restore normal flexion-extension (F-E) motion and coronal plane ligament balance, internal-external (I-E) rotation kinematics in the axial plane have been largely neglected. Recent in vivo evidence indicates that the combination of factors necessary to closely restore native tibial rotation as the knee flexes and extends is kinematic alignment (KA), which resurfaces the patient's pre-arthritic knee without releasing ligaments, an insert with medial 1:1 ball-in-socket conformity and a lateral flat surface, and posterior cruciate ligament (PCL) retention. However, the inherent anterior-posterior (A-P) stability provided by the medial 1:1 ball-in-socket limits the surgeon's ability to select the correct insert thickness using manual laxity testing. Accordingly, this review presents the design and validation of an instrument called an insert goniometer that measures I-E tibial rotation for inserts that differ in thickness by 1 mm and uses rotation limits at extension and 90° flexion to select the optimal insert thickness. The optimal thickness is the one that provides the greatest external tibial orientation in extension and internal tibial orientation at 90° flexion without lift-off of the insert.
Collapse
Affiliation(s)
- Sahil A. Sanghavi
- Department of Arthroplasty, Sancheti Institute for Orthopaedics and Rehabilitation, Pune 411005, India
| | - Alexander J. Nedopil
- Department of Orthopaedic Surgery, König-Ludwig-Haus, University of Würzburg, Brettreichstr. 11, 97074 Würzburg, Germany
| | - Stephen M. Howell
- Department of Biomedical Engineering, University of California at Davis, One Shields Avenue, Davis, CA 95616, USA
| | - Maury L. Hull
- Department of Biomedical Engineering, Department of Mechanical Engineering, Department of Orthopaedic Surgery, University of California at Davis, One Shields Avenue, Davis, CA 95616, USA
| |
Collapse
|
3
|
Ohyama Y, Kobayashi A, Minoda Y, Iwakiri K, Masuda S, Ohta Y, Sugama R, Nakamura H. Association Between Overhang of the Posterior Femoral Condyle and Restricted Postoperative Knee Flexion Related to Patient-Reported Stiffness in Medial-Pivot Total Knee Arthroplasty. J Arthroplasty 2024:S0883-5403(24)00919-7. [PMID: 39265813 DOI: 10.1016/j.arth.2024.08.058] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 04/22/2024] [Revised: 08/28/2024] [Accepted: 08/30/2024] [Indexed: 09/14/2024] Open
Abstract
BACKGROUND The primary aim of this study was to investigate the association between the posterior longitudinal overhang in the femoral condyle (PLOF) in medial-pivot total knee arthroplasty (TKA) and a change in knee flexion angle (change in flexion). METHODS This retrospective cohort study included 148 knees undergoing medial-pivot TKA for medial knee osteoarthritis. The primary outcome was the change in flexion (c-flexion) preoperatively and 1-year postoperatively. The component positions were evaluated using 3-dimensional measurements, where the PLOF was measured for each medial and lateral femoral condyle. The secondary outcome was the Western Ontario and McMaster Universities Osteoarthritis Index scores taken preoperatively and 2 years postoperatively. A multivariate regression analysis was performed to determine predictors of c-flexion and risk factors for negative c-flexion (less than 0°). Furthermore, a receiver operating characteristic curve was utilized to determine the threshold for negative c-flexion. RESULTS The mean c-flexion was -3.2° ± 8.7, and lateral PLOF was significantly associated with c-flexion (β = -0.52; P < 0.001). Larger preoperative flexion angles (odds ratio, 1.10; P < 0.001) and larger lateral PLOF (odds ratio, 1.69; P = 0.001) were risk factors for negative c-flexion, with thresholds of 129° and 1.1 mm, respectively (sensitivity, 0.79; specificity, 0.72). Additionally, patients who had negative c-flexion (n = 91) demonstrated less improvement in preoperative and 2-year postoperative Western Ontario and McMaster Universities Osteoarthritis Index stiffness subscores than patients who had positive c-flexion (0° or more; n = 57) (P = 0.01). CONCLUSIONS A larger lateral PLOF was associated with decreased and negative c-flexion after medial-pivot TKA. Patients who had negative c-flexion demonstrated less improvement in knee stiffness. Surgical strategies aimed at minimizing lateral PLOF may enhance postoperative knee flexion and overall patient outcomes in medial-pivot TKA.
Collapse
Affiliation(s)
- Yohei Ohyama
- Department of Orthopaedic Surgery, Osaka Metropolitan University Graduate School of Medicine, Osaka, Japan; Department of Orthopaedic Surgery, Shiraniwa Hospital Joint Arthroplasty Center, Nara, Japan
| | - Akio Kobayashi
- Department of Orthopaedic Surgery, Shiraniwa Hospital Joint Arthroplasty Center, Nara, Japan
| | - Yukihide Minoda
- Department of Orthopaedic Surgery, Osaka Metropolitan University Graduate School of Medicine, Osaka, Japan
| | - Kentaro Iwakiri
- Department of Orthopaedic Surgery, Shiraniwa Hospital Joint Arthroplasty Center, Nara, Japan
| | - Sho Masuda
- Department of Orthopaedic Surgery, Osaka Metropolitan University Graduate School of Medicine, Osaka, Japan
| | - Yoichi Ohta
- Department of Orthopaedic Surgery, Osaka Metropolitan University Graduate School of Medicine, Osaka, Japan; Department of Orthopaedic Surgery, Shiraniwa Hospital Joint Arthroplasty Center, Nara, Japan
| | - Ryo Sugama
- Department of Orthopaedic Surgery, Osaka Metropolitan University Graduate School of Medicine, Osaka, Japan
| | - Hiroaki Nakamura
- Department of Orthopaedic Surgery, Osaka Metropolitan University Graduate School of Medicine, Osaka, Japan
| |
Collapse
|
4
|
Harbison G, O'Donnell E, Elorza S, Howell SM, Hull ML. Retention of the posterior cruciate ligament stabilizes the medial femoral condyle during kneeling using a tibial insert with ball-in-socket medial conformity. INTERNATIONAL ORTHOPAEDICS 2024; 48:2395-2401. [PMID: 38997513 DOI: 10.1007/s00264-024-06251-z] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 05/14/2024] [Accepted: 07/03/2024] [Indexed: 07/14/2024]
Abstract
PURPOSE Resecting the posterior cruciate ligament (PCL) increases posterior laxity and increases the flexion gap more than the extension gap in the native (i.e. healthy) knee. These two effects could lead to significant anterior displacement of the medial femoral condyle in kneeling following total knee arthroplasty even when using a tibial insert with a high degree of medial conformity. Using an insert with ball-in-socket medial conformity and a flat lateral articular surface, the primary purpose was to determine whether the medial femoral condyle remained stable with and without PCL retention during kneeling. METHODS Two groups of patients were studied, one with PCL retention (22 patients) and the other with PCL resection (25 patients), while kneeling at 90º flexion. Following 3D model-to-2D image registration, A-P displacements of both femoral condyles were determined relative to the dwell point of the medial socket. RESULTS With PCL resection versus PCL retention, the medial femoral condyle was 5.1 ± 3.7 mm versus 0.8 ± 2.1 mm anterior of the dwell point (p < 0.0001). Patient-reported function scores were comparable (p ≥ 0.1610) despite a significantly shorter follow-up of 7.8 ± 0.9 months with PCL retention than 19.6 ± 4.9 months with PCL resection (p < 0.0001). Range of motion was 126 ± 8° versus 122 ± 6° with and without PCL retention, respectively (p = 0.057). CONCLUSION Surgeons that use a highly conforming tibial insert design can stabilize the medial femoral condyle during kneeling by retaining the PCL. In patients with PCL resection, the 9 mm high anterior lip of the insert with ball-in-socket medial conformity was insufficient to prevent significant anterior displacement of the medial femoral condyle when weight-bearing on the anterior tibia.
Collapse
Affiliation(s)
- Greg Harbison
- Department of Orthopaedic Surgery, University of California Davis Medical Center, Sacramento, CA, 95817, USA
| | - Ed O'Donnell
- Department of Orthopaedic Surgery, University of California Davis Medical Center, Sacramento, CA, 95817, USA
| | - Saul Elorza
- Department of Biomedical Engineering, University of California Davis, Davis, CA, 95616, USA
| | - S M Howell
- Department of Biomedical Engineering, University of California Davis, Davis, CA, 95616, USA
| | - M L Hull
- Department of Orthopaedic Surgery, University of California Davis Medical Center, Sacramento, CA, 95817, USA.
- Department of Biomedical Engineering, University of California Davis, Davis, CA, 95616, USA.
- Department of Mechanical Engineering, University of California Davis, Davis, CA, 95616, USA.
| |
Collapse
|
5
|
James Jensen A, Silva CS, Costello KE, Banks S. A novel post-processing technique for correcting symmetric implant ambiguity in measuring total knee arthroplasty kinematics from single-plane fluoroscopy. J Biomech 2024; 170:112172. [PMID: 38833908 DOI: 10.1016/j.jbiomech.2024.112172] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/23/2023] [Revised: 05/17/2024] [Accepted: 05/23/2024] [Indexed: 06/06/2024]
Abstract
Recent advancements in computer vision and machine learning enable autonomous measurement of total knee arthroplasty kinematics through single-plane fluoroscopy. However, symmetric components present challenges in optimization routines, causing "symmetry traps" and ambiguous poses. Achieving clinically robust kinematics measurement requires addressing this issue. We devised an algorithm that converts a "true" pose to its corresponding "symmetry trap" orientation. From a dataset of nearly 13,000 human supervised kinematics, this algorithm constructs an augmented dataset of "true" and "symmetry trap" kinematics, used to train eight classification machine learning algorithms. The outputs from the highest-performing algorithm classify kinematics sequences as 'obviously true' or 'potentially ambiguous.' We construct a spline through 'obviously true' poses, and 'ambiguous' poses are compared to the spline to determine correct orientation. The machine learning algorithms achieved 88-94% accuracy on our internal test set and 91-93% on our external test set. Applying our spline algorithm to kinematics sequences yielded 91.1% accuracy, 94% specificity, but 67% sensitivity. The accuracy of standard ML algorithms for implants within 5 degrees of a pure-lateral view was 71%, rising to 88% beyond 5 degrees. This pioneering study systematizes addressing model-image registration issues with symmetric tibial implants. High accuracy suggests potential use of ML algorithms to mitigate shape-ambiguity errors in pose measurements from single-plane fluoroscopy. Our results also suggest an imaging protocol for measuring kinematics that favors more oblique viewing angles, which could further disambiguate "true" and "symmetry trap" poses.
Collapse
Affiliation(s)
- Andrew James Jensen
- Department of Mechanical & Aerospace Engineering, PO Box 116250, Gainesville, FL 32611, USA.
| | - Catia S Silva
- Department of Electrical & Computer Engineering, 968 Center Drive, Gainesville, FL 32611, USA.
| | - Kerry E Costello
- Department of Mechanical & Aerospace Engineering, PO Box 116250, Gainesville, FL 32611, USA.
| | - Scott Banks
- Department of Mechanical & Aerospace Engineering, PO Box 116250, Gainesville, FL 32611, USA.
| |
Collapse
|
6
|
Hamilton LD, Shelburne KB, Rullkoetter PJ, Barnes CL, Mannen EM. Kinematic Performance of Medial Pivot Total Knee Arthroplasty. J Arthroplasty 2024; 39:1595-1601.e7. [PMID: 38061399 PMCID: PMC11096005 DOI: 10.1016/j.arth.2023.11.038] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 09/07/2023] [Revised: 11/16/2023] [Accepted: 11/27/2023] [Indexed: 12/30/2023] Open
Abstract
BACKGROUND Total knee arthroplasty (TKA) implants have continued to evolve to accommodate new understandings of knee mechanics. The medial-pivot implant is a newer design, which is intended to limit anterior-posterior translation in the medial compartment while allowing lateral compartment translation. However, evidence for a generalized medial-pivot characteristic across all activities is limited. The purpose of the study was to quantify and compare in vivo knee joint kinematics using high-speed stereo radiography during activities of daily living in patients who have undergone a TKA with a cruciate sacrificing medial-pivot implant to age-matched and sex-matched native controls. METHODS Fifteen participants (7 patients, 4 women, mean age 70 years and 8 nonsymptomatic controls, 4 women, mean age 64 years) performed 6 functional tasks in high-speed stereo radiography: deep-knee lunge, chair rise, step down, gait, gait with 90° turn, and seated knee extension. Translational differences between groups (surgical versus control) were assessed for the medial and lateral condyle, while pivot location was normalized to subject-specific tibial plateau geometry. RESULTS The surgical cohort displayed a more constrained medial condyle that provided greater stability of the medial compartment and did not result in the paradoxical anterior translation at mid-flexion angles during weight-bearing activities, but was associated with less condylar translation than native knees. Additionally, the transverse tibial pivot location occurs most commonly in the middle third of the tibial plateau and secondarily on the medial third. CONCLUSIONS Some variability in pivot location occurs between activities and is more in nonsymptomatic, native knee controls.
Collapse
Affiliation(s)
- Landon D Hamilton
- Department of Mechanical and Materials Engineering, University of Denver, Denver, Colorado
| | - Kevin B Shelburne
- Department of Mechanical and Materials Engineering, University of Denver, Denver, Colorado
| | - Paul J Rullkoetter
- Department of Mechanical and Materials Engineering, University of Denver, Denver, Colorado
| | - C Lowry Barnes
- Department of Orthopaedic Surgery, University of Arkansas for Medical Sciences, Little Rock, Arkansas
| | - Erin M Mannen
- Department of Orthopaedic Surgery, University of Arkansas for Medical Sciences, Little Rock, Arkansas; Department of Mechanical and Biomedical Engineering, Boise State University, Boise, Idaho
| |
Collapse
|
7
|
Hodgeson SM, Soeno T, Mears SC, Stambough JB, Barnes CL, Stronach BM. The Medial Pivot Design in Total Knee Arthroplasty. Orthop Clin North Am 2024; 55:49-59. [PMID: 37980103 DOI: 10.1016/j.ocl.2023.06.007] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/20/2023]
Abstract
Medial pivot total knee arthroplasty implants are designed to function in a similar manner to that of the native knee with a relatively fixed medial center of rotation and a less conforming lateral compartment that follows an arcuate path. Medial pivot implants in total knee arthroplasty have increased in popularity with many companies offering medial pivot or retrofitted medial congruent implants, and there are variations between the various medial pivot and medial congruent implants. Existing literature on medial pivot implants have demonstrated high survivorship and patient outcomes. More studies are needed to compare newer medial pivot implants with each other and with retrofitted medial congruent implants.
Collapse
Affiliation(s)
- Sydney M Hodgeson
- Department of Orthopaedics, University of Arkansas for Medical Sciences, 4301 West Markham Street, Slot 531, Little Rock, AR 72205, USA
| | - Tatsuya Soeno
- Department of Orthopaedics, University of Arkansas for Medical Sciences, 4301 West Markham Street, Slot 531, Little Rock, AR 72205, USA
| | - Simon C Mears
- Department of Orthopaedics, University of Arkansas for Medical Sciences, 4301 West Markham Street, Slot 531, Little Rock, AR 72205, USA
| | - Jeffrey B Stambough
- Department of Orthopaedics, University of Arkansas for Medical Sciences, 4301 West Markham Street, Slot 531, Little Rock, AR 72205, USA
| | - C Lowry Barnes
- Department of Orthopaedics, University of Arkansas for Medical Sciences, 4301 West Markham Street, Slot 531, Little Rock, AR 72205, USA
| | - Benjamin M Stronach
- Department of Orthopaedics, University of Arkansas for Medical Sciences, 4301 West Markham Street, Slot 531, Little Rock, AR 72205, USA.
| |
Collapse
|
8
|
Kono K, Yamazaki T, Tamaki M, Ishibashi T, Tanaka S, Tomita T. Effect of single-radius design on in vivo kinematics during stair activities after total knee arthroplasty. J Orthop Surg (Hong Kong) 2024; 32:10225536241246326. [PMID: 38652873 DOI: 10.1177/10225536241246326] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 04/25/2024] Open
Abstract
BACKGROUND The single-radius design is one of the major total knee arthroplasty (TKA) designs and widely used all over the world. The objective of this study was to compare in vivo kinematics between the anteroposterior (AP) single-radius design with mediolateral (ML) single-radius (Non Restricted Geometry; NRG) and ML dual-radius (Triathlon) during stair activities. METHODS A total of 21 knees in 18 patients (NRG group: 10 knees in 7 patients, Triathlon group: 11 knees in 11 patients) with a clinically successful posterior stabilized TKA were examined. Under fluoroscopic surveillance, each patient performed stair ascending and descending motions. In vivo kinematics were analyzed using 2D/3D registration technique. The knee flexion angle, rotation angle, varus-valgus angle, AP translation of the femorotibial contact point for both the medial and lateral sides of the knee, and post-cam engagement were evaluated. RESULTS There were no significant differences between the two groups in rotation angle and AP translation at each flexion angle. Examining the varus-valgus angle, the NRG group showed varus position at an early flexion angle during both stair activities.Post-cam engagement was observed in both groups during both stair activities. The mean flexion angle of engagement in the NRG group, the post of which was located anterior to the Triathlon, was larger than that in the Triathlon group during both stair activities. CONCLUSION Despite the same AP single-radius TKA, ML single-radius might affect varus motion at an early flexion angle.
Collapse
Affiliation(s)
- Kenichi Kono
- Department of Orthopedic Surgery, Faculty of Medicine, The University of Tokyo, Bunkyo, Japan
| | - Takaharu Yamazaki
- Department of Information Systems, Faculty of Engineering, Saitama Institute of Technology, Fukaya, Japan
| | - Masashi Tamaki
- Department of Orthopedic Biomaterial Science, Osaka UniversityGraduate School of Medicine, Suita, Japan
| | - Teruya Ishibashi
- Department of Orthopedic Biomaterial Science, Osaka UniversityGraduate School of Medicine, Suita, Japan
| | - Sakae Tanaka
- Department of Orthopedic Surgery, Faculty of Medicine, The University of Tokyo, Bunkyo, Japan
| | - Tetsuya Tomita
- Department of Orthopedic Biomaterial Science, Osaka UniversityGraduate School of Medicine, Suita, Japan
- Department of Health Science, Graduate School of Health Science, Morinomiya University of Medical Sciences, Suminoe, Japan
| |
Collapse
|
9
|
Jensen AJ, Flood PDL, Palm-Vlasak LS, Burton WS, Chevalier A, Rullkoetter PJ, Banks SA. Joint Track Machine Learning: An Autonomous Method of Measuring Total Knee Arthroplasty Kinematics From Single-Plane X-Ray Images. J Arthroplasty 2023; 38:2068-2074. [PMID: 37236287 DOI: 10.1016/j.arth.2023.05.029] [Citation(s) in RCA: 9] [Impact Index Per Article: 9.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 01/04/2023] [Revised: 05/11/2023] [Accepted: 05/17/2023] [Indexed: 05/28/2023] Open
Abstract
BACKGROUND Dynamic radiographic measurements of 3-dimensional (3-D) total knee arthroplasty (TKA) kinematics have provided important information for implant design and surgical technique for over 30 years. However, current methods of measuring TKA kinematics are too cumbersome, inaccurate, or time-consuming for practical clinical application. Even state-of-the-art techniques require human-supervision to obtain clinically reliable kinematics. Eliminating human supervision could potentially make this technology practical for clinical use. METHODS We demonstrate a fully autonomous pipeline for quantifying 3D-TKA kinematics from single-plane radiographic imaging. First, a convolutional neural network (CNN) segmented the femoral and tibial implants from the image. Second, those segmented images were compared to precomputed shape libraries for initial pose estimates. Lastly, a numerical optimization routine aligned 3D implant contours and fluoroscopic images to obtain the final implant poses. RESULTS The autonomous technique reliably produces kinematic measurements comparable to human-supervised measures, with root-mean-squared differences of less than 0.7 mm and 4° for our test data, and 0.8 mm and 1.7° for external validation studies. CONCLUSION A fully autonomous method to measure 3D-TKA kinematics from single-plane radiographic images produces results equivalent to a human-supervised method, and may soon make it practical to perform these measurements in a clinical setting.
Collapse
Affiliation(s)
- Andrew J Jensen
- Department of Mechanical and Aerospace Engineering, University of Florida, Gainesville, Florida
| | - Paris D L Flood
- Department of Computer Science, University of Cambridge, Cambridge, UK
| | - Lindsey S Palm-Vlasak
- Department of Mechanical and Aerospace Engineering, University of Florida, Gainesville, Florida
| | - William S Burton
- Center for Orthopaedic Biomechanics, University of Denver, Denver, Colorado
| | - Amélie Chevalier
- Electromechanical, Systems and Metals Engineering, Ghent University, Ghent, Belgium; Department of Electromechanics, CoSysLab, University of Antwerp, Antwerp, Belgium; AnSyMo/Cosys, Flanders Make, The Strategic Research Centre for the Manufacturing Industry, Antwerp, Belgium
| | - Paul J Rullkoetter
- Center for Orthopaedic Biomechanics, University of Denver, Denver, Colorado
| | - Scott A Banks
- Department of Mechanical and Aerospace Engineering, University of Florida, Gainesville, Florida
| |
Collapse
|
10
|
Scott DF, Hellie AA. Mid-Flexion, Anteroposterior Stability of Total Knee Replacement Implanted with Kinematic Alignment: A Randomized, Quantitative Radiographic Laxity Study with Posterior-Stabilized and Medial-Stabilized Implants. J Bone Joint Surg Am 2023; 105:9-19. [PMID: 36574642 DOI: 10.2106/jbjs.22.00549] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 12/28/2022]
Abstract
UPDATE This article was updated on January 4, 2023, because of a previous error, which was discovered after the preliminary version of the article was posted online. On page 16, in Figure 5, the x-axis that had read "P<0.0086" now reads "KSS Pain (p=0.02)," and the value for the MS group that had read "48.9" now reads "48.8."This article was updated on January 6, 2022, because of a previous error. On page 13, in the section entitled "Results," the sentence that had read "However, when only the subset of female subjects was considered, the MS group demonstrated significantly less anteroposterior laxity in 90° of flexion than the MS group (2.3 versus 5.4 mm; p = 0.008)." now reads "However, when only the subset of female subjects was considered, the MS group demonstrated significantly less anteroposterior laxity in 90° of flexion than the PS group (2.3 versus 5.4 mm; p = 0.008)." BACKGROUND Stability in mid-flexion is important for satisfactory clinical outcomes following total knee arthroplasty (TKA). The purpose of the present study was to compare the anteroposterior stability of knees that had been treated with a posterior-stabilized (PS) device or a medial-stabilized (MS) device. We hypothesized that mid-flexion laxity would be greater in the PS group and that clinical outcome scores would be better for the group with lower laxity. METHODS Sixty-three patients who had been randomly selected from a larger randomized, prospective, blinded clinical trial underwent primary TKA with either a PS implant (n = 30) or an MS implant (n = 33). Range of motion, the Knee Society Score (KSS), and the Forgotten Joint Score (FJS) were collected, and anteroposterior laxity with the knee in 45° and 90° of flexion was evaluated with stress radiographs. RESULTS In 45° of flexion, the MS group demonstrated significantly less total anteroposterior displacement than the PS group (mean, 3.6 versus 16.5 mm; p ≤ 0.0001). In 90° of flexion, the total anteroposterior displacement was not significantly different for the 2 groups when both male and female patients were included (mean, 3.9 versus 5.9; p = 0.07). However, when only the subset of female subjects was considered, the MS group demonstrated significantly less anteroposterior laxity in 90° of flexion than the PS group (2.3 versus 5.4 mm; p = 0.008). The groups did not differ significantly in terms of preoperative age, body mass index, sex distribution, FJS, KSS, or range of motion, and they also did not differ in terms of postoperative FJS or range of motion. However, all 33 patients in the MS group returned to sports as indicated in question 12 of the FJS, compared with 19 subjects in the PS group (p = 0.0001). The postoperative KSS Pain, Pain/Motion, and Function scores were all significantly higher in the MS group than the PS; specifically, the mean KSS Pain score was 48.8 in the MS group, compared with 44.8 in the PS group (p = 0.02); the mean KSS Pain/Motion score was 98.4 in the MS group, compared with 89.5 in the PS group (p < 0.0001); and the mean KSS Function score was 95.5 in the MS group, compared with 85.7 in the PS group (p = 0.003). CONCLUSIONS Mid-flexion laxity was greater in patients with PS implants than in those with MS implants, and laxity in 90° was greater in the subset of female patients in the PS group. The decreased laxity observed in the MS group correlated with higher KSS Pain, Pain/Motion, and Function scores as well as with a higher rate of return to sports activities. LEVEL OF EVIDENCE Therapeutic Level I . See Instructions for Authors for a complete description of levels of evidence.
Collapse
Affiliation(s)
- David F Scott
- Spokane Joint Replacement Center, Inc., Spokane, Washington.,Elson S. Floyd College of Medicine, Washington State University, Spokane, Washington
| | - Amy A Hellie
- Spokane Joint Replacement Center, Inc., Spokane, Washington
| |
Collapse
|
11
|
Bauer L, Thorwächter C, Steinbrück A, Jansson V, Traxler H, Alic Z, Holzapfel BM, Woiczinski M. Does Posterior Tibial Slope Influence Knee Kinematics in Medial Stabilized TKA? J Clin Med 2022; 11:jcm11226875. [PMID: 36431352 PMCID: PMC9698522 DOI: 10.3390/jcm11226875] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/03/2022] [Revised: 10/26/2022] [Accepted: 11/17/2022] [Indexed: 11/23/2022] Open
Abstract
BACKGROUND During total knee arthroplasty (TKA), one of the key alignment factors to pay attention to is the posterior tibial slope (PTS). The PTS clearly influences the kinematics of the knee joint but must be adapted to the coupling degree of the specific TKA design. So far, there is hardly any literature including clear recommendations for how surgeons should choose the PTS in a medial stabilized (MS) TKA. The aim of the present study is to investigate the effects of different degrees of PTS on femorotibial kinematics in MS TKA. MATERIALS AND METHODS An MS TKA was performed in seven fresh-frozen human specimens successively with 0°, 3°, and 6° of PTS. After each modification, weight-bearing deep knee flexion (30-130°) was performed, and femorotibial kinematics were analyzed. RESULTS A lateral femoral rollback was observed for all three PTS modifications. With an increasing PTS, the tibia was shifted more anteriorly on the lateral side (0° PTS anterior tibial translation -9.09 (±9.19) mm, 3° PTS anterior tibial translation -11.03 (±6.72) mm, 6° PTS anterior tibial translation 11.86 (±9.35) mm). No difference in the tibial rotation was found for the different PTS variants. All PTS variants resulted in internal rotation of the tibia during flexion. With a 3° PTS, the design-specific medial rotation point was achieved more accurately. CONCLUSIONS According to our findings, we recommend a PTS of 3° when implanting the MS prosthesis used in this study.
Collapse
Affiliation(s)
- Leandra Bauer
- Department of Orthopaedics and Trauma Surgery, Musculoskeletal University Center Munich (MUM), University Hospital, LMU Munich, Marchioninistraße 15, 81377 Munich, Germany
| | - Christoph Thorwächter
- Department of Orthopaedics and Trauma Surgery, Musculoskeletal University Center Munich (MUM), University Hospital, LMU Munich, Marchioninistraße 15, 81377 Munich, Germany
| | - Arnd Steinbrück
- Department of Orthopaedics and Trauma Surgery, Musculoskeletal University Center Munich (MUM), University Hospital, LMU Munich, Marchioninistraße 15, 81377 Munich, Germany
- Orthopaedic Surgical Competence Center Augsburg (OCKA), Vinzenz-von-Paul-Platz 1, 86152 Augsburg, Germany
| | - Volkmar Jansson
- Department of Orthopaedics and Trauma Surgery, Musculoskeletal University Center Munich (MUM), University Hospital, LMU Munich, Marchioninistraße 15, 81377 Munich, Germany
- German Arthroplasty Registry (EPRD Deutsche Endoprothesenregister gGmbH), Straße des 17. Juni 106-108, 10623 Berlin, Germany
| | - Hannes Traxler
- Center for Anatomy and Cell Biology, Division of Anatomy, Medical University of Vienna (MedUni Vienna), Waehringer Str. 13, 1090 Vienna, Austria
| | - Zumreta Alic
- Center for Anatomy and Cell Biology, Division of Anatomy, Medical University of Vienna (MedUni Vienna), Waehringer Str. 13, 1090 Vienna, Austria
| | - Boris Michael Holzapfel
- Department of Orthopaedics and Trauma Surgery, Musculoskeletal University Center Munich (MUM), University Hospital, LMU Munich, Marchioninistraße 15, 81377 Munich, Germany
| | - Matthias Woiczinski
- Department of Orthopaedics and Trauma Surgery, Musculoskeletal University Center Munich (MUM), University Hospital, LMU Munich, Marchioninistraße 15, 81377 Munich, Germany
- Correspondence:
| |
Collapse
|
12
|
Grupp TM, Schilling C, Fritz B, Puente Reyna AL, Rusch S, Taunt C, Mihalko WM. Endurance Behavior of Cemented Tibial Tray Fixation Under Anterior Shear and Internal-External Torsional Shear Testing: A New Methodological Approach. J Arthroplasty 2022; 37:2272-2281. [PMID: 35588902 DOI: 10.1016/j.arth.2022.05.021] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 01/27/2022] [Revised: 04/24/2022] [Accepted: 05/10/2022] [Indexed: 02/02/2023] Open
Abstract
BACKGROUND Early total knee arthroplasty failures continue to surface in the literature. Cementation technique and implant design are two of the most important scenarios that can affect implant survivorship. Our objectives were to develop a more suitable preclinical test to evaluate the endurance of the implant-cement-bone interface under anterior shear and internal-external (I/E) torsional shear testing condition in a biomechanical sawbones. METHODS Implants tested included the AS VEGA System PS and the AS Columbus CR/PS (Aesculap AG, Germany), with zirconium nitride (ZrN) coating. Tibial implants were evaluated under anterior shear and I/E torsional shear conditions with 6 samples in 4 test groups. For the evaluation of the I/E torsional shear endurance behavior, a test setup was created allowing for clinically relevant I/E rotation with simultaneous high axial/tibio-femoral load. The test was performed with an I/E displacement of ±17.2°, for 1 million cycles with an axial preload of 3,000 N. RESULTS After the anterior shear test an implant-cement-bone fixation strength for the AS VEGA System tibial tray of 2,674 ± 754 N and for the AS Columbus CR/PS tibial tray of 2,177 ± 429 N was determined (P = .191). After I/E rotational shear testing an implant-cement-bone fixation strength for the AS VEGA System PS tray of 2,561 ± 519 N and for the AS Columbus CR/PS tray of 2,824 ± 515 N was resulted (P = .39). CONCLUSION Both methods had varying degrees of failure modes from debonding to failure of the sawbones foam. These two intense biomechanical loading tests are more strenuous and more representative of clinical activity.
Collapse
Affiliation(s)
- Thomas M Grupp
- Aesculap AG Research & Development, Tuttlingen, Germany; Ludwig Maximilians University Munich, Department of Orthopaedic and Trauma Surgery, Musculoskeletal University Center Munich (MUM), Campus Grosshadern, Munich, Germany
| | | | | | | | - Sabine Rusch
- Aesculap AG Research & Development, Tuttlingen, Germany
| | | | - William M Mihalko
- Campbell Clinic Department of Orthopaedic Surgery & Biomedical Eng., University of Tennessee Health Science Center, Memphis, Tennessee
| |
Collapse
|
13
|
Kage T, Inui H, Tomita T, Yamazaki T, Taketomi S, Yamagami R, Kono K, Kawaguchi K, Murakami R, Arakawa T, Tanaka S. In vivo kinematic comparison of medial pivot total knee arthroplasty in weight-bearing and non-weight-bearing deep knee bending. Clin Biomech (Bristol, Avon) 2022; 99:105762. [PMID: 36148703 DOI: 10.1016/j.clinbiomech.2022.105762] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 04/15/2022] [Revised: 08/05/2022] [Accepted: 09/06/2022] [Indexed: 02/07/2023]
Abstract
BACKGROUND This study aimed to determine the kinematics of medial pivot total knee arthroplasty by comparing weight-bearing and non-weight-bearing deep knee bending and to evaluate the effect of the weight-bearing state on the kinematics. METHODS The kinematics of 19 knees were investigated under fluoroscopy during squatting (weight-bearing) and active-assisted knee bending (non-weight-bearing) using two- to three-dimensional registration technique. Accordingly, range of motion, anteroposterior translation for the medial and lateral low contact points, axial rotation of the femoral component relative to the tibial component and kinematic pathway were evaluated. FINDINGS There was no difference in range of motion between the two states. The medial anteroposterior translation showed no significant movement with no anterior translation in both the weight-bearing and non-weight-bearing from 0° to 90° of flexion. Regarding the lateral anteroposterior translation, a posterior translation was observed during weight-bearing, whereas a slight anterior translation from 0° to 30° of flexion and subsequent posterior translation were found in the non-weight-bearing. Femoral external rotation was observed in the weight-bearing, whereas femoral internal rotation was seen from 0° to 30° of flexion and subsequent femoral external rotation was observed in the non-weight-bearing. The kinematic pathway showed medial pivot motion and subsequent bicondylar rollback in the weight-bearing, whereas only medial pivot motion was observed in the non-weight-bearing. INTERPRETATION The medial anteroposterior translation of the femur during deep knee bending showed no anterior motion in the two states. The lateral anteroposterior translation and femoral rotation were different in the mid-flexion range between the two states.
Collapse
Affiliation(s)
- Tomofumi Kage
- Department of Orthopaedic Surgery, Faculty of Medicine, The University of Tokyo, 7-3-1 Hongo, Bunkyo-ku, Tokyo 113-8655, Japan
| | - Hiroshi Inui
- Department of Orthopaedic Surgery, Faculty of Medicine, The University of Tokyo, 7-3-1 Hongo, Bunkyo-ku, Tokyo 113-8655, Japan.
| | - Tetsuya Tomita
- Department of Orthopaedic Biomaterial Science, Osaka University Graduate School of Medicine, 2-2 Yamada-oka, Suita, Osaka 565-0871, Japan
| | - Takaharu Yamazaki
- Department of Information Systems, Faculty of Engineering, Saitama Institute of Technology, 1690 Fusaiji, Fukaya, Saitama 369-0293, Japan
| | - Shuji Taketomi
- Department of Orthopaedic Surgery, Faculty of Medicine, The University of Tokyo, 7-3-1 Hongo, Bunkyo-ku, Tokyo 113-8655, Japan
| | - Ryota Yamagami
- Department of Orthopaedic Surgery, Faculty of Medicine, The University of Tokyo, 7-3-1 Hongo, Bunkyo-ku, Tokyo 113-8655, Japan
| | - Kenichi Kono
- Department of Orthopaedic Surgery, Faculty of Medicine, The University of Tokyo, 7-3-1 Hongo, Bunkyo-ku, Tokyo 113-8655, Japan
| | - Kohei Kawaguchi
- Department of Orthopaedic Surgery, Faculty of Medicine, The University of Tokyo, 7-3-1 Hongo, Bunkyo-ku, Tokyo 113-8655, Japan
| | - Ryo Murakami
- Department of Orthopaedic Surgery, Faculty of Medicine, The University of Tokyo, 7-3-1 Hongo, Bunkyo-ku, Tokyo 113-8655, Japan
| | - Takahiro Arakawa
- Department of Orthopaedic Surgery, Faculty of Medicine, The University of Tokyo, 7-3-1 Hongo, Bunkyo-ku, Tokyo 113-8655, Japan
| | - Sakae Tanaka
- Department of Orthopaedic Surgery, Faculty of Medicine, The University of Tokyo, 7-3-1 Hongo, Bunkyo-ku, Tokyo 113-8655, Japan
| |
Collapse
|
14
|
Kage T, Inui H, Tomita T, Yamazaki T, Taketomi S, Yamagami R, Kono K, Kawaguchi K, Takagi K, Sameshima S, Tanaka S. The Association between In Vivo Knee Kinematics and Patient-Reported Outcomes during Squatting in Bicruciate-Stabilized Total Knee Arthroplasty. J Knee Surg 2022; 35:1342-1348. [PMID: 33545725 DOI: 10.1055/s-0041-1723763] [Citation(s) in RCA: 6] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 02/07/2023]
Abstract
Bicruciate-stabilized total knee arthroplasty (BCS TKA) has been developed to improve TKA kinematic performance. However, the relationship between in vivo kinematics and patient-reported outcomes (PROs) has not been well described. This study was performed to clarify the relationship between in vivo kinematics and PROs in a cohort of patients undergoing BCS TKA. Forty knees were evaluated using a two-dimensional to three-dimensional registration technique obtained from sagittal plane fluoroscopy. In vivo kinematics including anteroposterior (AP) translation and tibiofemoral rotation were evaluated. Knee Society scores (KSSs) and Knee injury and Osteoarthritis Outcome Scores (KOOSs) were assessed before and after surgery. Relationships between tibiofemoral kinematics assessed with the knee in different positions of knee flexion and PROs were evaluated using Spearman's correlation analysis. The study demonstrated a significant negative correlation (r = - 0.33) between medial AP translation from minimum flexion to 30 degrees flexion and postoperative KOOS activities of daily living subscale. A significant positive correlation (r = 0.51) was found between the femoral external rotation from minimum flexion to 30 degrees flexion and improvement of the KOOS pain subscale. No correlation was found between the lateral AP translation and PROs. Achieving medial AP and femoral external rotation stability in early flexion may be important in optimizing postoperative PROs.
Collapse
Affiliation(s)
- Tomofumi Kage
- Department of Orthopaedic Surgery, Faculty of Medicine, The University of Tokyo, Tokyo, Japan
| | - Hiroshi Inui
- Department of Orthopaedic Surgery, Faculty of Medicine, The University of Tokyo, Tokyo, Japan
| | - Tetsuya Tomita
- Department of Orthopaedic Biomaterial Science, Graduate School of Medicine, Osaka University, Osaka, Japan
| | - Takaharu Yamazaki
- Department of Information Systems, Faculty of Engineering, Saitama Institute of Technology, Fukaya, Saitama, Japan
| | - Shuji Taketomi
- Department of Orthopaedic Surgery, Faculty of Medicine, The University of Tokyo, Tokyo, Japan
| | - Ryota Yamagami
- Department of Orthopaedic Surgery, Faculty of Medicine, The University of Tokyo, Tokyo, Japan
| | - Kenichi Kono
- Department of Orthopaedic Surgery, Faculty of Medicine, The University of Tokyo, Tokyo, Japan
| | - Kohei Kawaguchi
- Department of Orthopaedic Surgery, Faculty of Medicine, The University of Tokyo, Tokyo, Japan
| | - Kentaro Takagi
- Department of Orthopaedic Surgery, Faculty of Medicine, The University of Tokyo, Tokyo, Japan
| | - Shin Sameshima
- Department of Orthopaedic Surgery, Faculty of Medicine, The University of Tokyo, Tokyo, Japan
| | - Sakae Tanaka
- Department of Orthopaedic Surgery, Faculty of Medicine, The University of Tokyo, Tokyo, Japan
| |
Collapse
|
15
|
A TKA Insert with A Lateral Flat Articular Surface Maximizes External and Internal Tibial Orientations without Anterior Lift-Off Relative to Low- and Ultracongruent Surfaces. J Pers Med 2022; 12:jpm12081274. [PMID: 36013223 PMCID: PMC9410386 DOI: 10.3390/jpm12081274] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/10/2022] [Revised: 07/30/2022] [Accepted: 07/30/2022] [Indexed: 01/15/2023] Open
Abstract
Background: In total knee arthroplasty (TKA), inserts can have different levels of medial and lateral congruency determined by the acuteness of the upslopes of the anterior and posterior articular surfaces. The present study evaluated an insert with different levels of lateral congruency and a medial ball-in-socket congruency to test the hypothesis that a lateral flat (F) insert maximizes external tibial orientation at extension and internal orientation at 90° flexion and lowers the incidence of anterior lift-off relative to low-congruent (LC) and ultracongruent (UC) lateral inserts. Methods: Two surgeons treated 23 patients with unrestricted caliper-verified kinematic alignment (KA) and posterior cruciate ligament (PCL) retention. They randomly trialed inserts with a medial radial dial that functioned as a built-in goniometer by measuring the tibial orientation relative to a sagittal line on the femoral trial component. Anterior lift-off of the insert from the baseplate indicated PCL tightness. Results: The F insert’s mean of 9° of external tibial orientation was higher than that of the LC (5°, p < 0.0001) and UC inserts (2°, p < 0.0001). The −13° of internal tibial orientation at 90° flexion was higher than that of the LC (−9°, p < 0.0001) and UC inserts (−7°, p < 0.0001). The 0% incidence of anterior lift-off was less than that of the LC (26%) and UC inserts (57%) (p < 0.0001). Conclusions: Surgeons and implant manufacturers should know that adding congruency to the lateral articular surface limits external tibial orientation in extension and internal tibial orientation at 90° flexion and overtightens the PCL. These rotational limitations and flexion space tightness can adversely affect patellofemoral tracking and knee flexion.
Collapse
|
16
|
Scott DF, Gray CG. Outcomes are Better With a Medial-Stabilized vs a Posterior-Stabilized Total Knee Implanted With Kinematic Alignment. J Arthroplasty 2022; 37:S852-S858. [PMID: 35189286 DOI: 10.1016/j.arth.2022.02.059] [Citation(s) in RCA: 5] [Impact Index Per Article: 2.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 11/22/2021] [Revised: 02/04/2022] [Accepted: 02/14/2022] [Indexed: 02/02/2023] Open
Abstract
BACKGROUND There is no consensus whether a posterior-stabilized (PS) total knee device is superior to a more congruent, cruciate-substituting, medial-stabilized device (MS). This study compared the clinical outcomes of these devices. The primary hypothesis was that the clinical outcomes would be better in the MS group implanted with kinematic alignment. METHODS This prospective, randomized, single-center Level 1 study compared the outcomes of 99 patients who received a PS device and 101 patients who received an MS device implanted with kinematic alignment. Institutional Review Board approval and informed consent were obtained. Clinical and radiographic assessments were performed preoperatively, 6 weeks, 6 months, and annually. RESULTS All subjects reached the minimum follow-up of 2 years. There were no statistically significant differences in demographic characteristics, preoperative scores, or alignment (preoperative or postoperative). Tourniquet time was 7.24% longer for the PS group (40.28 min vs 37.56 min, P < .0086). There were significant differences between groups for the 1-year and 2-year Knee Society scores, Forgotten Joint Score, and ROM; in every case favoring the MS group. The FJS was 68.3 in the MS group at 2 years and 58.3 in the PS group (P = .02). The maximum flexion at 2 years was 132° in the MS group and 124° in the PS group (P < .0001). CONCLUSION The clinical outcomes of the MS group at 1 and 2 years were better. At the minimum 2-year follow-up, the results demonstrate the superiority of the medial-stabilized device in terms of multiple clinical outcomes. LEVEL OF EVIDENCE I.
Collapse
Affiliation(s)
- David F Scott
- Spokane Joint Replacement Center Inc., Spokane, Washington; Washington State University, Elson S. Floyd College of Medicine, Spokane, Washington
| | - Celeste G Gray
- Spokane Joint Replacement Center Inc., Spokane, Washington
| |
Collapse
|
17
|
Postolka B, Taylor WR, List R, Fucentese SF, Koch PP, Schütz P. ISB clinical biomechanics award winner 2021: Tibio-femoral kinematics of natural versus replaced knees - A comparison using dynamic videofluoroscopy. Clin Biomech (Bristol, Avon) 2022; 96:105667. [PMID: 35636308 DOI: 10.1016/j.clinbiomech.2022.105667] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 08/31/2021] [Revised: 05/06/2022] [Accepted: 05/11/2022] [Indexed: 02/07/2023]
Abstract
BACKGROUND A comparison of natural versus replaced tibio-femoral kinematics in vivo during challenging activities of daily living can help provide a detailed understanding of the mechanisms leading to unsatisfactory results and lay the foundations for personalised implant selection and surgical implantation, but also enhance further development of implant designs towards restoring physiological knee function. The aim of this study was to directly compare in vivo tibio-femoral kinematics in natural versus replaced knees throughout complete cycles of different gait activities using dynamic videofluoroscopy. METHODS Twenty-seven healthy and 30 total knee replacement subjects (GMK Sphere, GMK PS, GMK UC) were assessed during multiple complete gait cycles of level walking, downhill walking, and stair descent using dynamic videofluoroscopy. Following 2D/3D registration, tibio-femoral rotations, condylar antero-posterior translations, and the location of the centre of rotation were compared. FINDINGS The total knee replacement groups predominantly experienced reduced tibial internal/external rotation and altered medial and lateral condylar antero-posterior translations compared to natural knees. An average medial centre of rotation was found for the natural and GMK sphere groups in all three activities, whereas the GMK PS and UC groups experienced a more central to lateral centre of rotation. INTERPRETATION Each total knee replacement design exhibited characteristic motion patterns, with the GMK Sphere most closely replicating the medial centre of rotation found for natural knees. Despite substantial similarities between the subject groups, none of the implant geometries was able to replicate all aspects of natural tibio-femoral kinematics, indicating that different implant geometries might best address individual functional needs.
Collapse
Affiliation(s)
- Barbara Postolka
- Laboratory for Movement Biomechanics, Institute for Biomechanics, ETH Zürich, Leopold-Ruzicka-Weg 4, 8093 Zürich, Switzerland.
| | - William R Taylor
- Laboratory for Movement Biomechanics, Institute for Biomechanics, ETH Zürich, Leopold-Ruzicka-Weg 4, 8093 Zürich, Switzerland
| | - Renate List
- Laboratory for Movement Biomechanics, Institute for Biomechanics, ETH Zürich, Leopold-Ruzicka-Weg 4, 8093 Zürich, Switzerland; Human Performance Lab, Schulthess Clinic, Lengghalde 2, 8008 Zürich, Switzerland
| | - Sandro F Fucentese
- Balgrist University Hospital, Forchstrasse 340, 8008 Zürich, Switzerland
| | - Peter P Koch
- Winterthur Cantonal Hospital, Brauerstrasse 15, 8401 Winterthur, Switzerland
| | - Pascal Schütz
- Laboratory for Movement Biomechanics, Institute for Biomechanics, ETH Zürich, Leopold-Ruzicka-Weg 4, 8093 Zürich, Switzerland
| |
Collapse
|
18
|
Øhrn FD, Lian ØB, Tsukanaka M, Röhrl SM. Early migration of a medially stabilized total knee arthroplasty : a radiostereometric analysis study up to two years. Bone Jt Open 2021; 2:737-744. [PMID: 34493056 PMCID: PMC8479839 DOI: 10.1302/2633-1462.29.bjo-2021-0115.r1] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 11/25/2022] Open
Abstract
Aims Medial pivot (MP) total knee arthroplasties (TKAs) were designed to mimic native knee kinematics with their deep medial congruent fitting of the tibia to the femur almost like a ball-on-socket, and a flat lateral part. GMK Sphere is a novel MP implant. Our primary aim was to study the migration pattern of the tibial tray of this TKA. Methods A total of 31 patients were recruited to this single-group radiostereometric analysis (RSA) study and received a medial pivot GMK Sphere TKA. The distributions of male patients versus female patients and right versus left knees were 21:10 and 17:14, respectively. Mean BMI was 29 kg/m2 (95% confidence interval (CI) 27 to 30) and mean age at surgery was 63 years (95% CI 61 to 66). Maximum total point motions (MTPMs), medial, proximal, and anterior translations and transversal, internal, and varus rotations were calculated at three, 12, and 24 months. Patient-reported outcome measure data were also retrieved. Results MTPMs at three, 12, and 24 months were 1.0 mm (95% CI 0.8 to 1.2), 1.3 mm (95% CI 0.9 to 1.7), and 1.4 mm (0.8 to 2.0), respectively. The Forgotten Joint Score was 79 (95% CI 39 to 95) and Knee Injury and Osteoarthritis Outcome Score obtained at two years was 94 (95% CI 81 to 100), 86 (95% CI 75 to 93), 94 (95% CI 88 to 100), 69 (95% CI 48 to 88), and 81 (95% CI59 to 100) for Pain, Symptoms, Activities of Daily Living, Sport & Recreation, and Quality of Life, respectively. Conclusion In conclusion, we found that the mean increase in MTPM was lower than 0.2 mm between 12 and 24 months and thus apparently stable. Yet the GMK Sphere had higher migration at one and two years than anticipated. Based on current RSA data, we therefore cannot conclude on the long-term performance of the implant, pending further assessment. Cite this article: Bone Jt Open 2021;2(9):737–744.
Collapse
Affiliation(s)
- Frank-David Øhrn
- Kristiansund Hospital, Møre and Romsdal Health Trust, Kristiansund, Norway.,Department of Neuromedicine and Movement Science, NTNU Norwegian University of Science and Technology, Trondheim, Norway
| | - Øystein Bjerkestrand Lian
- Kristiansund Hospital, Møre and Romsdal Health Trust, Kristiansund, Norway.,Department of Neuromedicine and Movement Science, NTNU Norwegian University of Science and Technology, Trondheim, Norway
| | - Masako Tsukanaka
- Institute of Clinical Medicine, University of Oslo, Oslo, Norway
| | - Stephan Maximillian Röhrl
- Institute of Clinical Medicine, University of Oslo, Oslo, Norway.,Division of Orthopaedic Surgery, Oslo University Hospital, Oslo, Norway
| |
Collapse
|
19
|
Ghirardelli S, Asay JL, Leonardi EA, Amoroso T, Andriacchi TP, Indelli PF. Kinematic Comparison between Medially Congruent and Posterior-Stabilized Third-Generation TKA Designs. J Funct Morphol Kinesiol 2021; 6:jfmk6010027. [PMID: 33804113 PMCID: PMC8006233 DOI: 10.3390/jfmk6010027] [Citation(s) in RCA: 6] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 01/20/2021] [Revised: 03/05/2021] [Accepted: 03/10/2021] [Indexed: 11/16/2022] Open
Abstract
Background: This study compares knee kinematics in two groups of patients who have undergone primary total knee arthroplasty (TKA) using two different modern designs: medially congruent (MC) and posterior-stabilized (PS). The aim of the study is to demonstrate only minimal differences between the groups. Methods: Ten TKA patients (4 PS, 6 MC) with successful clinical outcomes were evaluated through 3D knee kinematics analysis performed using a multicamera optoelectronic system and a force platform. Extracted kinematic data included knee flexion angle at heel-strike (KFH), peak midstance knee flexion angle (MSKFA), maximum and minimum knee adduction angle (KAA), and knee rotational angle at heel-strike. Data were compared with a group of healthy controls. Results: There were no differences in preferred walking speed between MC and PS groups, but we found consistent differences in knee function. At heel-strike, the knee tended to be more flexed in the PS group compared to the MC group; the MSKFA tended to be higher in the PS group compared to the MC group. There was a significant fluctuation in KAA during the swing phase in the PS group compared to the MC group, PS patients showed a higher peak knee flexion moment compared to MC patients, and the PS group had significantly less peak internal rotation moments than the MC group. Conclusions: Modern, third-generation TKA designs failed to reproduce normal knee kinematics. MC knees tended to reproduce a more natural kinematic pattern at heel-strike and during axial rotation, while PS knees showed better kinematics during mid-flexion.
Collapse
|
20
|
Lynch JT, Scarvell JM, Galvin CR, Smith PN, Perriman DM. Influence of component design on in vivo tibiofemoral contact patterns during kneeling after total knee arthroplasty: a systematic review and meta-analysis. Knee Surg Sports Traumatol Arthrosc 2021; 29:446-466. [PMID: 32242268 DOI: 10.1007/s00167-020-05949-y] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 12/03/2019] [Accepted: 03/20/2020] [Indexed: 11/30/2022]
Abstract
PURPOSE Modern TKR prostheses are designed to restore healthy kinematics including high flexion. Kneeling is a demanding high-flexion activity. There have been many studies of kneeling kinematics using a plethora of implant designs but no comprehensive comparisons. Visualisation of contact patterns allows for quantification and comparison of knee kinematics. The aim of this systematic review was to determine whether there are any differences in the kinematics of kneeling as a function of TKR design. METHODS A search of the published literature identified 26 articles which were assessed for methodologic quality using the MINORS instrument. Contact patterns for different implant designs were compared at 90° and maximal flexion using quality-effects meta-analysis models. RESULTS Twenty-five different implants using six designs were reported. Most of the included studies had small-sample sizes, were non-consecutive, and did not have a direct comparison group. Only posterior-stabilised fixed-bearing and cruciate-retaining fixed-bearing designs had data for more than 200 participants. Meta-analyses revealed that bicruciate-stabilised fixed-bearing designs appeared to achieve more flexion and the cruciate-retaining rotating-platform design achieved the least, but both included single studies only. All designs demonstrated posterior-femoral translation and external rotation in kneeling, but posterior-stabilised designs were more posterior at maximal flexion when compared to cruciate retaining. However, the heterogeneity of the mean estimates was substantial, and therefore, firm conclusions about relative behaviour cannot be drawn. CONCLUSION The high heterogeneity may be due to a combination of variability in the kneeling activity and variations in implant geometry within each design category. There remains a need for a high-quality prospective comparative studies to directly compare designs using a common method. LEVEL OF EVIDENCE Systematic review and meta-analysis Level IV.
Collapse
Affiliation(s)
- Joseph T Lynch
- The Trauma and Orthopaedic Research Unit, Australian National University, The Canberra Hospital, Building 6, Level 1, Garran, ACT, Australia.
| | | | - Catherine R Galvin
- College of Engineering and Computer Science, Australian National University, Acton, ACT, Australia
| | - Paul N Smith
- The Trauma and Orthopaedic Research Unit, Australian National University, The Canberra Hospital, Building 6, Level 1, Garran, ACT, Australia
| | - Diana M Perriman
- The Trauma and Orthopaedic Research Unit, Australian National University, The Canberra Hospital, Building 6, Level 1, Garran, ACT, Australia
| |
Collapse
|
21
|
Alesi D, Marcheggiani Muccioli GM, Roberti di Sarsina T, Bontempi M, Pizza N, Zinno R, Di Paolo S, Zaffagnini S, Bragonzoni L. In vivo femorotibial kinematics of medial-stabilized total knee arthroplasty correlates to post-operative clinical outcomes. Knee Surg Sports Traumatol Arthrosc 2021; 29:491-497. [PMID: 32253483 DOI: 10.1007/s00167-020-05975-w] [Citation(s) in RCA: 28] [Impact Index Per Article: 9.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 12/22/2019] [Accepted: 03/30/2020] [Indexed: 12/22/2022]
Abstract
PURPOSE To evaluate if there was a correlation between in vivo kinematics of a medial-stabilized (MS) total knee arthroplasty (TKA) and post-operative clinical scores. We hypothesized that (1) a MS-TKA would produce a medial pivot movement and that (2) this specific pattern would be correlated with higher clinical scores. METHODS 18 patients were evaluated through clinical and functional scores evaluation (Knee Society Score clinical and functional, Womac, Oxford), and kinematically through dynamic radiostereometric analysis (RSA) at 9 months after MS-TKA, during the execution of a sit-to-stand and a lunge motor task. The anteroposterior (AP) Low Point translation of medial and lateral femoral compartments was compared through Student's t test (p < 0.05). A correlation analysis between scores and kinematics was performed through the Pearson's correlation coefficient r. RESULTS A significantly greater (p < 0.0001) anterior translation of the lateral compartment with respect to the medial one was found in both sit-to-stand (medial 2.9 mm ± 0.7 mm, lateral 7.1 mm ± 0.6 mm) and lunge (medial 5.3 mm ± 0.9 mm, lateral 10.9 mm ± 0.7 mm) motor tasks, thus resulting in a medial pivot pattern in about 70% of patients. Significant positive correlation in sit-to-stand was found between the peak of AP translation in the lateral compartment and clinical scores (r = 0.59 for Knee Society Score clinical and r = 0.61 for Oxford). Moreover, we found that the higher peak of AP translation of the medial compartment correlated with lower clinical scores (r = - 0.55 for Knee Society Score clinical, r = - 0.61 for Womac and r = - 0.53 for Oxford) in the lunge. A negative correlation was found between Knee Society Score clinical and VV laxity during sit-to-stand (r = - 0.56) and peak of external rotation in the lunge motor task (r = - 0.66). CONCLUSIONS The MS-TKA investigated produced in vivo a medial pivot movement in about 70% of patients in both examined motor tasks. There was a correlation between the presence of medial pivot and higher post-operative scores. LEVEL OF EVIDENCE IV.
Collapse
Affiliation(s)
- Domenico Alesi
- 2nd Orthopaedic and Traumatologic Clinic, IRCCS, Istituto Ortopedico Rizzoli, Via G.B. Pupilli 1, 40136, Bologna, Italy
| | - Giulio Maria Marcheggiani Muccioli
- 2nd Orthopaedic and Traumatologic Clinic, IRCCS, Istituto Ortopedico Rizzoli, Via G.B. Pupilli 1, 40136, Bologna, Italy. .,University of Bologna, Bologna, Italy.
| | - Tommaso Roberti di Sarsina
- 2nd Orthopaedic and Traumatologic Clinic, IRCCS, Istituto Ortopedico Rizzoli, Via G.B. Pupilli 1, 40136, Bologna, Italy
| | - Marco Bontempi
- 2nd Orthopaedic and Traumatologic Clinic, IRCCS, Istituto Ortopedico Rizzoli, Via G.B. Pupilli 1, 40136, Bologna, Italy
| | - Nicola Pizza
- 2nd Orthopaedic and Traumatologic Clinic, IRCCS, Istituto Ortopedico Rizzoli, Via G.B. Pupilli 1, 40136, Bologna, Italy
| | - Raffaele Zinno
- 2nd Orthopaedic and Traumatologic Clinic, IRCCS, Istituto Ortopedico Rizzoli, Via G.B. Pupilli 1, 40136, Bologna, Italy
| | - Stefano Di Paolo
- 2nd Orthopaedic and Traumatologic Clinic, IRCCS, Istituto Ortopedico Rizzoli, Via G.B. Pupilli 1, 40136, Bologna, Italy
| | - Stefano Zaffagnini
- 2nd Orthopaedic and Traumatologic Clinic, IRCCS, Istituto Ortopedico Rizzoli, Via G.B. Pupilli 1, 40136, Bologna, Italy.,University of Bologna, Bologna, Italy
| | | |
Collapse
|
22
|
Thomeer L, Guan S, Gray H, Schache A, de Steiger R, Pandy M. Six-Degree-of-Freedom Tibiofemoral and Patellofemoral Joint Motion During Activities of Daily Living. Ann Biomed Eng 2020; 49:1183-1198. [PMID: 33094419 DOI: 10.1007/s10439-020-02646-2] [Citation(s) in RCA: 10] [Impact Index Per Article: 2.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/03/2020] [Accepted: 09/30/2020] [Indexed: 11/30/2022]
Abstract
The purpose of this study was to measure the three-dimensional movements of the femur, tibia and patella in healthy young people during activities of daily living. A mobile biplane X-ray imaging system was used to obtain simultaneous measurements of six-degree-of-freedom (6-DOF) tibiofemoral and patellofemoral kinematics and femoral condylar motion in ten participants during standing, level walking, downhill walking, stair ascent, stair descent and open-chain (non-weightbearing) knee flexion. Seven of the eleven secondary motions at the knee-three translations at the tibiofemoral joint, three translations at the patellofemoral joint, and patellar flexion-were coupled to the tibiofemoral flexion angle (r2 ≥ 0.71). Tibial internal-external rotation, tibial abduction-adduction, patellar rotation, and patellar tilt were each weakly related to the tibiofemoral flexion angle (r2 ≤ 0.45). The displacements of the femoral condyles were also coupled to the tibiofemoral flexion angle (r2 ≥ 0.70), with the lateral condyle translating further on the tibial plateau than the medial condyle. The center of rotation of the tibiofemoral joint in the transverse plane was located on the medial side in all activities. These findings expand our understanding of the kinematic function of the healthy knee and may be relevant to a range of applications in biomechanics, including the design of prosthetic knee implants and the development of knee models for use in full-body simulations of movement.
Collapse
Affiliation(s)
- Lucas Thomeer
- Department of Mechanical Engineering, University of Melbourne, Parkville, VIC, 3010, Australia
| | - Shanyuanye Guan
- Department of Mechanical Engineering, University of Melbourne, Parkville, VIC, 3010, Australia
| | - Hans Gray
- Department of Mechanical Engineering, University of Melbourne, Parkville, VIC, 3010, Australia
| | - Anthony Schache
- Department of Mechanical Engineering, University of Melbourne, Parkville, VIC, 3010, Australia
| | - Richard de Steiger
- Department of Surgery, Epworth Health Care, University of Melbourne, Richmond, VIC, 3010, Australia
| | - Marcus Pandy
- Department of Mechanical Engineering, University of Melbourne, Parkville, VIC, 3010, Australia.
| |
Collapse
|
23
|
Esposito F, Freddolini M, Marcucci M, Latella L, Corvi A. Biomechanical analysis on total knee replacement patients during gait: Medial pivot or posterior stabilized design? Clin Biomech (Bristol, Avon) 2020; 78:105068. [PMID: 32535478 DOI: 10.1016/j.clinbiomech.2020.105068] [Citation(s) in RCA: 7] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 04/16/2019] [Revised: 03/03/2020] [Accepted: 05/26/2020] [Indexed: 02/07/2023]
Abstract
BACKGROUND Total Knee Replacement surgery restores joint function in patients with advanced osteoarthritis. There are several prostheses available based on different mechanisms, which guarantee knee stability during Activities of Daily Living. The aim of this study is to compare ball-in-socket (or Medial Pivot) and post-cam mechanisms to detect possible differences in terms of biomechanical parameters between these two prosthesis designs and to evaluate which design is closer to physiological biomechanics. METHODS A kinematics, kinetics and electromyography lower limb analyses were performed during gait on sixty subjects: twenty with Medial Pivot prosthesis, twenty with posterior stabilized prosthesis and twenty healthy subjects to obtain a physiologic reference. FINDINGS Total Knee Replacement gait pattern for both patient groups were characterized by reduced walking speed, reduced stride length and increased stance time respect to control group. Comparison between Medial Pivot and Posterior Stabilized groups showed a reduction of knee flexion and flexor moment in patients with ball-in-socket mechanism. A prolonged muscular activity of rectus femoris was observed in Medial Pivot patients compared to Posterior Stabilized and control groups. INTERPRETATION "Stiff knee pattern" mechanism was showed for both patient groups but more enhanced in Medial Pivot patients. Even though the Posterior Stabilized design introduces the non-physiological paradoxical motion and the Medial Pivot design seems to better reproduce the physiological condylar movement as gait analysis parameters, including kinematics, kinetics and electromyographic parameters were closer to control group and, in turn, to physiological gait for the Posterior Stabilized than Medial Pivot group parameters.
Collapse
Affiliation(s)
- Francesco Esposito
- Laboratorio congiunto di Analisi del Movimento, "Fondazione ONLUS: In cammino…", Piazza Spartaco Lavignini 1, 50054 Fucecchio (FI), Italy; Industrial Engineering Department, University of Florence, Via di S. Marta 3, 50139 Firenze (FI), Italy.
| | - Marco Freddolini
- Italian Institute of Technology, Via Morego 30, 16163 Genova (GE), Italy
| | - Massimiliano Marcucci
- Laboratorio congiunto di Analisi del Movimento, "Fondazione ONLUS: In cammino…", Piazza Spartaco Lavignini 1, 50054 Fucecchio (FI), Italy; "Centro di Eccellenza Sostituzioni Articolari Toscana (C.E.S.A.T.)", Piazza Spartaco Lavignini 1, 50054 Fucecchio (FI), Italy; Health Sciences Department, University of Florence, Viale Pieraccini 6, 50139 Firenze (FI), Italy
| | - Leonardo Latella
- Laboratorio congiunto di Analisi del Movimento, "Fondazione ONLUS: In cammino…", Piazza Spartaco Lavignini 1, 50054 Fucecchio (FI), Italy; "Centro di Eccellenza Sostituzioni Articolari Toscana (C.E.S.A.T.)", Piazza Spartaco Lavignini 1, 50054 Fucecchio (FI), Italy
| | - Andrea Corvi
- Laboratorio congiunto di Analisi del Movimento, "Fondazione ONLUS: In cammino…", Piazza Spartaco Lavignini 1, 50054 Fucecchio (FI), Italy; Industrial Engineering Department, University of Florence, Via di S. Marta 3, 50139 Firenze (FI), Italy
| |
Collapse
|
24
|
Gray HA, Guan S, Young TJ, Dowsey MM, Choong PF, Pandy MG. Comparison of posterior-stabilized, cruciate-retaining, and medial-stabilized knee implant motion during gait. J Orthop Res 2020; 38:1753-1768. [PMID: 31994751 DOI: 10.1002/jor.24613] [Citation(s) in RCA: 44] [Impact Index Per Article: 11.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 08/08/2019] [Revised: 12/18/2019] [Accepted: 01/21/2020] [Indexed: 02/04/2023]
Abstract
Accurate knowledge of knee joint motion is needed to evaluate the effects of implant design on functional performance and component wear. We conducted a randomized controlled trial to measure and compare 6-degree-of-freedom (6-DOF) kinematics and femoral condylar motion of posterior-stabilized (PS), cruciate-retaining (CR), and medial-stabilized (MS) knee implant designs for one cycle of walking. A mobile biplane X-ray imaging system was used to accurately measure 6-DOF tibiofemoral motion as patients implanted with PS (n = 23), CR (n = 25), or MS (n = 26) knees walked over ground at their self-selected speeds. Knee flexion angle did not differ significantly between the three designs. Relative movements of the femoral and tibial components were generally similar for PS and CR with significant differences observed only for anterior tibial drawer. Knee kinematic profiles measured for MS were appreciably different: external rotation and abduction of the tibia were increased while peak-to-peak anterior drawer was significantly reduced for MS compared with PS and CR. Anterior-posterior drawer and medial-lateral shift of the tibia were strongly coupled to internal-external rotation for MS, as was anterior-posterior translation of the contact center in the lateral compartment. MS exhibited the least amount of paradoxical anterior translation of the femur relative to the tibia during knee flexion. The joint center of rotation in the transverse plane was located in the lateral compartment for PS and CR and in the medial compartment for MS. Substantial differences were evident in 6-DOF knee kinematics between the healthy knee and all three prosthetic designs. Overall, knee kinematic profiles observed for MS resemble those of the healthy joint more closely than PS and CR.
Collapse
Affiliation(s)
- Hans A Gray
- Department of Mechanical Engineering, University of Melbourne, Parkville, Victoria, Australia
| | - Shanyuanye Guan
- Department of Mechanical Engineering, University of Melbourne, Parkville, Victoria, Australia
| | - Tony J Young
- Department of Surgery, St. Vincent's Hospital, University of Melbourne, Fitzroy, Victoria, Australia
- Department of Orthopaedics, St. Vincent's Hospital, Fitzroy, Victoria, Australia
| | - Michelle M Dowsey
- Department of Surgery, St. Vincent's Hospital, University of Melbourne, Fitzroy, Victoria, Australia
- Department of Orthopaedics, St. Vincent's Hospital, Fitzroy, Victoria, Australia
| | - Peter F Choong
- Department of Surgery, St. Vincent's Hospital, University of Melbourne, Fitzroy, Victoria, Australia
- Department of Orthopaedics, St. Vincent's Hospital, Fitzroy, Victoria, Australia
| | - Marcus G Pandy
- Department of Mechanical Engineering, University of Melbourne, Parkville, Victoria, Australia
| |
Collapse
|
25
|
Øhrn FD, Gøthesen Ø, Låstad Lygre SH, Peng Y, Lian ØB, Lewis PL, Furnes O, Röhrl SM. Decreased Survival of Medial Pivot Designs Compared with Cruciate-retaining Designs in TKA Without Patellar Resurfacing. Clin Orthop Relat Res 2020; 478:1207-1218. [PMID: 31977446 PMCID: PMC7319362 DOI: 10.1097/corr.0000000000001120] [Citation(s) in RCA: 14] [Impact Index Per Article: 3.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 01/31/2023]
Abstract
BACKGROUND The medial pivot TKA design was introduced in the 1990s. These are fixed-bearing, medial-conforming implants with virtually no translation in the medial part of the knee, in contrast to the flat lateral part of the insert allowing for translation similar to the native knee during flexion and extension. Most primary TKAs performed in Norway and Australia are cruciate-retaining. All of the medial pivot implants in our study are cruciate-sacrificing but without a post-cam mechanism. The medial pivot implant design was developed to more closely mimic native knee motion, in the hope of improving function, and not primarily as a more constrained knee for difficult cases. In the past 10 to 12 years, a second-generation medial-pivot design has emerged, but there are no larger registry studies on the survival of these implants. Both cruciate-retaining and medial pivot designs are reported in the Australian and Norwegian registries, allowing for large-scale, comparative survivorship studies. QUESTIONS/PURPOSES (1) Is there any difference in survival between the medial pivot design and the three most commonly used cruciate-retaining TKA designs? (2) Is there any difference in survival among the different medial pivot implant designs? (3) What are the main indications for revision of medial pivot TKAs? METHODS Registry data from the Australian Orthopaedic Association National Joint Replacement Registry and Norwegian Arthroplasty Register from 2005 until the end of 2017 were used to compare the five different brands of medial pivot TKA designs (total primary TKAs assessed: 6310). In Australia, the study group of medial pivot implants represented 9% (6012 of 72,477) of the total number of cemented/hybrid TKAs without patellar resurfacing; 345 had cementless femoral components. In Norway, the study group represented 1% (298 of 47,820) of the total number of TKAs with cemented tibias without patellar resurfacing; all had cemented femoral components. The control group consisted of the three most commonly used cruciate-retaining TKA designs (n = 70,870; Australia n = 54,554; Norway n = 16,316). All TKAs used a fixed-bearing, cemented tibial component and did not involve patella resurfacing. Kaplan-Meier survival analysis was assessed to estimate survivorship. We compared the groups by calculating the hazard ratios (HR) using Cox regression adjusted for age, gender and preoperative diagnosis with 95% CI. To answer our third question, we calculated the percentage of each revision indication from the total number of revisions in each group, and used a Cox regression analysis to compare revision causes and HRs. Analyses were performed separately by each registry. Accounting for competing risks (Fine and Gray) did not alter our findings []. RESULTS After controlling for potential confounding variables such as gender, age and preoperative diagnosis, we found an increased revision risk for the medial pivot compared with cruciate-retaining TKA designs in Australia (HR 1.4 [95% CI 1.2 to 1.7]; p < 0.001), but not in Norway (HR 1.5 [95% CI 0.9 to 2.4]; p = 0.1). Two brands of the medial pivot design reported to the AOANJRR showed an increased risk of revision compared with cruciate-retaining designs: the Advance® II MP (HR 1.7 [95% CI 1.2 to 2.6]; p = 0.004) and the GMK® Sphere (HR 2.0 [95% CI 1.5 to 2.6]; p < 0.001), whereas the MRK (HR 0.7 [95% CI 0.4 to 1.5]; p = 0.4), the Evolution® MP (HR 1.4 [95% CI 1.0 to 1.9]; p = 0.06) and the SAIPH® (HR 0.9 [95% CI 0.5 to 1.5]; p = 0.7) showed no difference. The most common reasons for revision of medial pivot implants in Australia were infection (27%), pain alone (19%), patellar erosion (13%), loosening/lysis (12%); in Norway the primary indications were loosening/lysis (28%), instability (28%), malalignment (11%) and pain alone (11%). CONCLUSIONS The medial pivot TKA design as a group had a higher revision rate than cruciate-retaining fixed-bearing controls in TKA performed without patellar component resurfacing. By brand, the Advance II MP and the GMK Sphere had inferior survivorship, whereas the MRK, the SAIPH and the Evolution MP had no differences in survivorship compared with cruciate-retaining controls. In Australia, TKAs with the medial pivot design without patella resurfacing had a higher rate of revisions for instability, malalignment, and patella erosion. In Norway, there was an increased risk of revision for lysis and loosening compared with the cruciate-retaining design. Several of these implants had short follow-up in this study. Further registry studies with longer follow up are therefore necessary. LEVEL OF EVIDENCE Level III, therapeutic study.
Collapse
|
26
|
Are TKA Kinematics During Closed Kinetic Chain Exercises Associated with Patient-reported Outcomes? A Preliminary Analysis. Clin Orthop Relat Res 2020; 478:255-263. [PMID: 31634171 PMCID: PMC7438127 DOI: 10.1097/corr.0000000000000991] [Citation(s) in RCA: 29] [Impact Index Per Article: 7.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 01/31/2023]
Abstract
BACKGROUND Kinematic patterns after TKA can vary considerably from those of the native knee. It is unknown, however, if there is a relationship between a given kinematic pattern and patient satisfaction after TKA. QUESTIONS/PURPOSES Is there an association between kinematic patterns as measured by AP translation during open kinetic chain flexion-extension and closed kinetic chain exercises (rising from a chair and squatting) and a custom aggregate of patient-reported outcome measures (PROMs) that targeted symptoms, pain, activities of daily living (ADL), sports, quality of life (QOL), and patient satisfaction after TKA? METHODS Thirty patients who underwent TKA between 2014 and 2016 were tested at a minimum follow-up of 6 months. As three different implants were used, per implant the first 10 patients who presented themselves at the follow-up consultations and were able to bend the knee at least 90°, were recruited. Tibiofemoral kinematics during an open kinetic chain flexion-extension and closed kinetic chain exercises-rising from a chair and squatting-were analyzed using fluoroscopy. A two-step cluster analysis was performed, resulting in two clusters of patients who answered the Knee Injury and Osteoarthritis Outcome Score and the satisfaction subscore of the Knee Society Score questionnaires. Cluster 1 (CL1) consisted of patients with better (good-to-excellent) patient-reported outcome measures scores (high-PROMs cluster); Cluster 2 (CL2) consisted of patients with poorer scores (low-PROMs cluster). Tibiofemoral kinematics were compared between patients in these clusters by performing a Mann-Whitney U test with Bonferroni correction. RESULTS Concerning open kinetic chain flexion-extension, there was no difference in kinematic patterns between the patients in the high-PROMs cluster and those in the low-PROMs cluster, with the numbers available. However, during the closed-chain kinetic exercises, medially, initial anterior translation (femur relative to tibia) was found in patients in Cluster 1 during early flexion, but in those in Cluster 2, translation was steeper and ran more anteriorly (CL1 -1.5 ± 7.3%; CL2 -8.5 ± 4.4%); mean difference 7.0% [95% CI 0.1 to 13.8]; p = 0.046). In midflexion, the femur did not translate anterior nor posterior in relation to the tibia, resulting in a stable medial compartment in Cluster 1, whereas Cluster 2 had already started translating posteriorly (CL1 -0.7 ± 3.5%; CL2 3.4 ± 3.6%; mean difference -4.1% [95% CI -7.0 to -1.2]; p = 0.008). There was no difference, with the numbers available, between the two clusters with respect to posterior translation in deep flexion. Laterally, there was small initial anterior translation in early flexion, followed by posterior translation in midflexion that continued in deep flexion. Patients in Cluster 1 demonstrated more pronounced posterior translation in deep flexion laterally than patients in Cluster 2 did (CL1 8.3 ± 5.2%; CL2 3.5 ± 4.5%); mean difference 4.9% [95% CI 0.6 to 9.1]; p = 0.026). CONCLUSIONS This study of total knee kinematics suggests that during closed kinetic chain movements, patients with poor PROM scores after TKA experience more anterior translation on the medial side followed by a medial mid-flexion instability and less posterior translation on the lateral side in deep flexion than patients with good PROM scores. The relationship of kinematic variations with patient-reported outcomes including satisfaction must be further elaborated and translated into TKA design and position. Reproduction of optimal kinematic patterns during TKA could be instrumental in improving patient satisfaction after total knee replacement. Future expansion of the study group is needed to confirm these findings.Level of Evidence Level II, therapeutic study.
Collapse
|
27
|
Hosseini Nasab SH, Smith CR, Schütz P, Postolka B, List R, Taylor WR. Elongation Patterns of the Collateral Ligaments After Total Knee Arthroplasty Are Dominated by the Knee Flexion Angle. Front Bioeng Biotechnol 2019; 7:323. [PMID: 31799245 PMCID: PMC6861521 DOI: 10.3389/fbioe.2019.00323] [Citation(s) in RCA: 17] [Impact Index Per Article: 3.4] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/04/2019] [Accepted: 10/28/2019] [Indexed: 11/13/2022] Open
Abstract
The primary aim of this study was to assess the effects of total knee arthroplasty (TKA) implant design on collateral ligament elongation patterns that occur during level walking, downhill walking, and stair descent. Using a moving fluoroscope, tibiofemoral kinematics were captured in three groups of patients with different TKA implant designs, including posterior stabilized, medial stabilized, and ultra-congruent. The 3D in vivo joint kinematics were then fed into multibody models of the replaced knees and elongation patterns of virtual bundles connecting origin and insertion points of the medial and lateral collateral ligaments (MCL and LCL) were determined throughout complete cycles of all activities. Regardless of the implant design and activity type, non-isometric behavior of the collateral ligaments was observed. The LCL shortened with increasing knee flexion, while the MCL elongation demonstrated regional variability, ranging from lengthening of the anterior bundle to slackening of the posterior bundle. The implant component design did not demonstrate statistically significant effects on the collateral elongation patterns and this was consistent between the studied activities. This study revealed that post-TKA collateral ligament elongation is primarily determined by the knee flexion angle. The different anterior translation and internal rotation that were induced by three distinctive implant designs had minimal impact on the length change patterns of the collateral ligaments.
Collapse
Affiliation(s)
| | - Colin R Smith
- Laboratory for Movement Biomechanics, Institute for Biomechanics, ETH Zurich, Zurich, Switzerland
| | - Pascal Schütz
- Laboratory for Movement Biomechanics, Institute for Biomechanics, ETH Zurich, Zurich, Switzerland
| | - Barbara Postolka
- Laboratory for Movement Biomechanics, Institute for Biomechanics, ETH Zurich, Zurich, Switzerland
| | - Renate List
- Laboratory for Movement Biomechanics, Institute for Biomechanics, ETH Zurich, Zurich, Switzerland
| | - William R Taylor
- Laboratory for Movement Biomechanics, Institute for Biomechanics, ETH Zurich, Zurich, Switzerland
| |
Collapse
|
28
|
Schütz P, Taylor WR, Postolka B, Fucentese SF, Koch PP, Freeman MA, Pinskerova V, List R. Kinematic Evaluation of the GMK Sphere Implant During Gait Activities: A Dynamic Videofluoroscopy Study. J Orthop Res 2019; 37:2337-2347. [PMID: 31304995 PMCID: PMC6851890 DOI: 10.1002/jor.24416] [Citation(s) in RCA: 43] [Impact Index Per Article: 8.6] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 10/26/2018] [Accepted: 07/02/2019] [Indexed: 02/04/2023]
Abstract
Joint stability is a primary concern in total knee joint replacement. The GMK Sphere prosthesis was specifically designed to provide medial compartment anterior-posterior (A-P) stability, while permitting rotational freedom of the joint through a flat lateral tibial surface. The objective of this study was to establish the changes in joint kinematics introduced by the GMK Sphere prosthesis during gait activities in comparison to conventional posterior-stabilized (PS) fixed-bearing and ultra-congruent (UC) mobile-bearing geometries. The A-P translation and internal/external rotation of three cohorts, each with 10 good outcome subjects (2.9 ± 1.6 years postop), with a GMK Sphere, GMK PS or GMK UC implant were analysed throughout complete cycles of gait activities using dynamic videofluoroscopy. The GMK Sphere showed the smallest range of medial compartment A-P translation for level walking, downhill walking, and stair descent (3.6 ± 0.9 mm, 3.1 ± 0.8 mm, 3.9 ± 1.3 mm), followed by the GMK UC (5.7 ± 1.0 mm, 8.0 ± 1.7 mm, 8.7 ± 1.9 mm) and the GMK PS (10.3 ± 2.2 mm, 10.1 ± 2.6 mm, 11.6 ± 1.6 mm) geometries. The GMK Sphere exhibited the largest range of lateral compartment A-P translation (12.1 ± 2.2 mm), and the largest range of tibial internal/external rotation (13.2 ± 2.2°), both during stair descent. This study has shown that the GMK Sphere clearly restricts A-P motion of the medial condyle during gait activities while still allowing a large range of axial rotation. The additional comparison against the conventional GMK PS and UC geometries, not only demonstrates that implant geometry is a key factor in governing tibio-femoral kinematics, but also that the geometry itself probably plays a more dominant role for joint movement than the type of gait activity. © 2019 The Authors. Journal of Orthopaedic Research® published by Wiley Periodicals, Inc. on behalf of Orthopaedic Research Society. J Orthop Res 37:2337-2347, 2019.
Collapse
Affiliation(s)
- Pascal Schütz
- Institute for Biomechanics, D‐HESTETH ZurichZurichSwitzerland
| | | | | | | | - Peter P. Koch
- Klinik für Orthopädie und TraumatologieWinterthur Cantonal HospitalWinterthurSwitzerland
| | | | - Vera Pinskerova
- First Orthopaedic Clinic, Faculty of MedicineCharles UniversityPragueCzech Republic
| | - Renate List
- Institute for Biomechanics, D‐HESTETH ZurichZurichSwitzerland
| |
Collapse
|
29
|
Angerame MR, Holst DC, Jennings JM, Komistek RD, Dennis DA. Total Knee Arthroplasty Kinematics. J Arthroplasty 2019; 34:2502-2510. [PMID: 31229370 DOI: 10.1016/j.arth.2019.05.037] [Citation(s) in RCA: 48] [Impact Index Per Article: 9.6] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 10/19/2018] [Revised: 05/20/2019] [Accepted: 05/21/2019] [Indexed: 02/01/2023] Open
Abstract
Knee kinematics is an analysis of motion pattern that is utilized to assess a comparative, biomechanical performance of healthy nonimplanted knees, injured nonimplanted knees, and various prosthetic knee designs. Unfortunately, a consensus between implanted knee kinematics and outcomes has not been reached. One might hypothesize that the kinematic variances between the nonimplanted and implanted knee might play a role in patient dissatisfaction following TKA. There is a wide range of TKA designs available today. With such variety, it is important for surgeons and engineers to understand the various geometries and kinematic profiles of available prostheses. The purpose of this review is to provide readers with the pertinent information related to TKA kinematics.
Collapse
Affiliation(s)
| | - David C Holst
- Department of Orthopedic Surgery, Duke University, Raleigh, NC
| | - Jason M Jennings
- Colorado Joint Replacement, Porter Adventist Hospital, Denver, CO; Department of Biomedical Engineering, University of Denver, Denver, CO
| | - Richard D Komistek
- Department of Biomedical Engineering, University of Tennessee, Knoxville, TN
| | - Douglas A Dennis
- Colorado Joint Replacement, Porter Adventist Hospital, Denver, CO; Department of Biomedical Engineering, University of Denver, Denver, CO; Department of Biomedical Engineering, University of Tennessee, Knoxville, TN; Department of Orthopaedics, University of Colorado Health School of Medicine, Aurora, CO
| |
Collapse
|
30
|
Key S, Scott G, Stammers JG, Freeman MAR, Pinskerova V, Field RE, Skinner J, Banks SA. Does lateral lift-off occur in static and dynamic activity in a medially spherical total knee arthroplasty? A pulsed-fluoroscopic investigation. Bone Joint Res 2019; 8:207-215. [PMID: 31214333 PMCID: PMC6548977 DOI: 10.1302/2046-3758.85.bjr-2018-0237.r1] [Citation(s) in RCA: 9] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 12/20/2022] Open
Abstract
OBJECTIVES The medially spherical GMK Sphere (Medacta International AG, Castel San Pietro, Switzerland) total knee arthroplasty (TKA) was previously shown to accommodate lateral rollback while pivoting around a stable medial compartment, aiming to replicate native knee kinematics in which some coronal laxity, especially laterally, is also present. We assess coronal plane kinematics of the GMK Sphere and explore the occurrence and pattern of articular separation during static and dynamic activities. METHODS Using pulsed fluoroscopy and image matching, the coronal kinematics and articular surface separation of 16 well-functioning TKAs were studied during weight-bearing and non-weight-bearing, static, and dynamic activities. The closest distances between the modelled articular surfaces were examined with respect to knee position, and proportions of joint poses exhibiting separation were computed. RESULTS Overall, 1717 joint poses were analyzed. At a 1.0 mm detection threshold, 37 instances of surface separation were observed in the lateral compartment and four medially (p < 0.001). Separation was activity-dependent, both laterally and medially (p < 0.001), occurring more commonly during static deep flexion in the lateral compartment, and during static rotation in the medial compartment. Lateral separation occurred more frequently than medial during kneeling (7/14 lateral vs 1/14 medial; p = 0.031) and stepping (20/1022 lateral vs 0/1022 medial; p < 0.001). Separation varied significantly between individuals during dynamic activities. CONCLUSION No consistent association between closest distances of the articular surfaces and knee position was found during any activity. Lift-off was infrequent and depended on the activity performed and the individual knee. Lateral separation was consistent with the design rationale. Medial lift-off was rare and mostly in non-weight-bearing activities.Cite this article: S. Key, G. Scott, J.G. Stammers, M. A. R. Freeman†, V. Pinskerova, R. E. Field, J. Skinner, S. A. Banks. Does lateral lift-off occur in static and dynamic activity in a medially spherical total knee arthroplasty? A pulsed-fluoroscopic investigation. Bone Joint Res 2019;8:207-215. DOI: 10.1302/2046-3758.85.BJR-2018-0237.R1.
Collapse
Affiliation(s)
- S Key
- Royal London Hospital, London, UK
| | - G Scott
- Royal London Hospital, London, UK
| | | | - M A R Freeman
- †M.A.R Freeman has deceased since the submission of this manuscript
| | - V Pinskerova
- First Orthopaedic Clinic, Faculty of Medicine, Charles University, Prague, Czech Republic
| | - R E Field
- St George's, University of London, London, UK; Director of Research, South West London Elective Orthopaedic Centre, Epsom, UK
| | - J Skinner
- Royal National Orthopaedic Hospital, Stanmore, UK
| | - S A Banks
- University of Florida, Gainesville, Florida, USA
| |
Collapse
|
31
|
Symmetrical cruciate-retaining versus medial pivot prostheses: The effect of intercondylar sagittal conformity on knee kinematics and contact mechanics. Comput Biol Med 2019; 108:101-110. [DOI: 10.1016/j.compbiomed.2019.03.005] [Citation(s) in RCA: 12] [Impact Index Per Article: 2.4] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/30/2018] [Revised: 03/06/2019] [Accepted: 03/07/2019] [Indexed: 01/28/2023]
|
32
|
Indelli PF, Risitano S, Hall KE, Leonardi E, Migliore E. Effect of polyethylene conformity on total knee arthroplasty early clinical outcomes. Knee Surg Sports Traumatol Arthrosc 2019; 27:1028-1034. [PMID: 30328496 DOI: 10.1007/s00167-018-5170-5] [Citation(s) in RCA: 31] [Impact Index Per Article: 6.2] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 04/06/2018] [Accepted: 09/21/2018] [Indexed: 11/25/2022]
Abstract
PURPOSE Total knee arthroplasty is a successful procedure in treating subjects with end-stage knee osteoarthritis. The objective of this matched study was to evaluate subjective patient satisfaction and clinical and radiological outcomes in two groups of patients undergoing primary TKA using an identical third-generation design with different conformity in the polyethylene insert. METHODS One hundred consecutive patients undergoing TKA because of knee osteoarthritis were randomized in two matched groups. Group A included 50 Posterior-Stabilized (PS) implants, while group B included 50 Medially Congruent (MC) implants. The surgical technique was identical: gap balancing in extension and measured resection in flexion; cruciate ligaments were always removed; the coronal alignment followed the mechanical axis and the tibial slope was set at 3° in the PS group and 5° in the MC. Oxford Knee Score (OKS) and Knee Society Score (KSS) were assessed preoperatively and at 2 year minimum follow-up. Two-sample T test statistical analysis was performed. RESULTS All patients were available at final follow-up: there were no preoperative statistical differences between the two groups in the average preoperative ROM (PS 112°, MC 108°; n.s.), average preoperative KSS (PS 64.4, MC 63.7; n.s.), average preoperative OKS (PS 19.6; MC 19.0; n.s.), and average BMI (PS 34.40, MC 34.60; n.s.). At final follow-up, there were no statistical differences between the two groups in the average OKS (PS 40,5; MC 41.1; n.s.) and in the average KSS (PS 161,5, MC 165,7; n.s.). We found a statistically but not clinically significant difference at final ROM: the average maximum active flexion was 120° in the PS group and 123° in the MC group (s.s.). CONCLUSION This study evaluated two biomechanically different polyethylene inserts in the same TKA design, showing that reducing the level of intra-articular conformity had minimal effects on PROMs and objective short-term clinical results but a potentially beneficial effect on ROM. This study suggests that, once a satisfactory intra-operative stability is obtained, the minimal level of constraint should be used. LEVEL OF EVIDENCE III.
Collapse
Affiliation(s)
- Pier Francesco Indelli
- Department Orthopaedic Surgery and Bioengineering, Stanford University School of Medicine, Stanford, USA.
- PAVAHCS, Surgical services, 1801 Miranda Ave, Palo Alto, CA, 94304, USA.
| | - Salvatore Risitano
- Department Orthopaedic Surgery and Bioengineering, Stanford University School of Medicine, Stanford, USA
- PAVAHCS, Surgical services, 1801 Miranda Ave, Palo Alto, CA, 94304, USA
| | - Kimberly E Hall
- Department Orthopaedic Surgery and Bioengineering, Stanford University School of Medicine, Stanford, USA
- PAVAHCS, Surgical services, 1801 Miranda Ave, Palo Alto, CA, 94304, USA
| | - Erika Leonardi
- Department Orthopaedic Surgery and Bioengineering, Stanford University School of Medicine, Stanford, USA
- PAVAHCS, Surgical services, 1801 Miranda Ave, Palo Alto, CA, 94304, USA
| | - Eleonora Migliore
- Department Orthopaedic Surgery and Bioengineering, Stanford University School of Medicine, Stanford, USA
- PAVAHCS, Surgical services, 1801 Miranda Ave, Palo Alto, CA, 94304, USA
| |
Collapse
|
33
|
Gray HA, Guan S, Thomeer LT, Schache AG, de Steiger R, Pandy MG. Three-dimensional motion of the knee-joint complex during normal walking revealed by mobile biplane x-ray imaging. J Orthop Res 2019; 37:615-630. [PMID: 30680795 DOI: 10.1002/jor.24226] [Citation(s) in RCA: 54] [Impact Index Per Article: 10.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 07/02/2018] [Accepted: 01/08/2019] [Indexed: 02/04/2023]
Abstract
Accurate knowledge of knee kinematics is important for a better understanding of normal joint function and for improving patient outcomes subsequent to joint reconstructive surgery. Limited information is available that accurately describes the relative movements of the bones at the knee in vivo, even for the most common of all activities: walking. We used a mobile X-ray imaging system to measure the three-dimensional motion of the entire knee-joint complex-femur, tibia, and patella-when humans walk over ground at their natural speeds. Data were recorded from 15 healthy individuals (9 males, 6 females; age 30.5 ± 6.2 years). The most pronounced rotational motion of the tibia was flexion-extension followed by internal-external rotation and abduction-adduction (peak-to-peak displacements: 70.7°, 9.2°, and 1.9°, respectively). Maximum anterior translation of the tibia was 6.5 mm and occurred in early swing, coinciding with peak knee flexion and peak internal rotation. The most prominent rotational motion of the patella was flexion-extension (peak-to-peak displacement: 50.5°). The tibia pivoted about the medial compartment of the tibiofemoral joint, conferring greater movements of the contact centers in the lateral compartment than the medial compartment (15.4 and 9.7 mm, respectively). Internal-external rotation, anterior-posterior translation and medial-lateral shift of the tibia as well as flexion-extension and anterior-posterior translation of the patella were each coupled to the knee flexion angle, as were movements of the contact centers at each joint. These fundamental data serve as a valuable resource for evaluating knee joint function in normal and pathological gait. The data are available in Supplementary_Material_Data.xlsx. © 2019 Orthopaedic Research Society. Published by Wiley Periodicals, Inc. J Orthop Res.
Collapse
Affiliation(s)
- Hans A Gray
- Department of Mechanical Engineering, University of Melbourne, Parkville, Victoria 3010, Australia
| | - Shanyuanye Guan
- Department of Mechanical Engineering, University of Melbourne, Parkville, Victoria 3010, Australia
| | - Lucas T Thomeer
- Department of Mechanical Engineering, University of Melbourne, Parkville, Victoria 3010, Australia
| | - Anthony G Schache
- Department of Mechanical Engineering, University of Melbourne, Parkville, Victoria 3010, Australia
| | - Richard de Steiger
- Department of Surgery, Epworth Health Care, University of Melbourne, Victoria 3010, Australia
| | - Marcus G Pandy
- Department of Mechanical Engineering, University of Melbourne, Parkville, Victoria 3010, Australia
| |
Collapse
|
34
|
Piolanti N, Polloni S, Bonicoli E, Giuntoli M, Scaglione M, Indelli PF. Giovanni Alfonso Borelli: The Precursor of Medial Pivot Concept in Knee Biomechanics. JOINTS 2018; 6:167-172. [PMID: 30582105 PMCID: PMC6301847 DOI: 10.1055/s-0038-1675164] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 08/13/2018] [Accepted: 09/09/2018] [Indexed: 12/02/2022]
Abstract
A new philosophy of science and medicine had spread throughout the 17th-century Italy: the “Scientific Revolution.” Giovanni Alfonso Borelli (1608–1679) was one of the most charismatic and brilliant scientists of his generation in Europe. He extended to biology the rigorous analytic methods developed by his indirect mentor Galileo in the field of mechanics. In his masterpiece “
De Motu Animalium
,” Borelli analyzed structure, motion, balance, and forces concerning almost all the principal joints of the human body, in static and dynamic situations. In particular, he accurately studied the anatomy and biomechanics of the knee joint. He sustained that femoral condyles shift backward during flexion, allowing a wider range of movement. Furthermore, he observed that, when the knee flexes, the lateral condyle moves backward more than the medial condyle: this concept is nowadays known as medial pivoting. The aim of this article is to describe the life and work of this important Italian scientist and to present his unrecognized contribution to modern knee biomechanics.
Collapse
Affiliation(s)
- Nicola Piolanti
- Dipartimento di Ricerca Traslazionale e delle Nuove Tecnologie in Medicina e Chirurgia, Università degli Studi di Pisa, Pisa, Italy
| | - Simone Polloni
- Dipartimento di Ricerca Traslazionale e delle Nuove Tecnologie in Medicina e Chirurgia, Università degli Studi di Pisa, Pisa, Italy
| | - Enrico Bonicoli
- Dipartimento di Ricerca Traslazionale e delle Nuove Tecnologie in Medicina e Chirurgia, Università degli Studi di Pisa, Pisa, Italy
| | - Michele Giuntoli
- Dipartimento di Ricerca Traslazionale e delle Nuove Tecnologie in Medicina e Chirurgia, Università degli Studi di Pisa, Pisa, Italy
| | - Michelangelo Scaglione
- Dipartimento di Ricerca Traslazionale e delle Nuove Tecnologie in Medicina e Chirurgia, Università degli Studi di Pisa, Pisa, Italy
| | - Pier Francesco Indelli
- Department of Orthopaedic Surgery, Stanford University School of Medicine, Stanford University, Stanford, California, United States
| |
Collapse
|
35
|
Young T, Dowsey MM, Pandy M, Choong PF. A Systematic Review of Clinical Functional Outcomes After Medial Stabilized Versus Non-Medial Stabilized Total Knee Joint Replacement. Front Surg 2018; 5:25. [PMID: 29696144 PMCID: PMC5905240 DOI: 10.3389/fsurg.2018.00025] [Citation(s) in RCA: 9] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/31/2017] [Accepted: 03/05/2018] [Indexed: 11/29/2022] Open
Abstract
BACKGROUND Medial stabilized total knee joint replacement (TKJR) construct is designed to closely replicate the kinematics of the knee. Little is known regarding comparison of clinical functional outcomes of patients utilising validated patient reported outcome measures (PROM) after medial stabilized TKJR and other construct designs. PURPOSE To perform a systematic review of the available literature related to the assessment of clinical functional outcomes following a TKJR employing a medial stabilized construct design. METHODS The review was performed with a Preferred Reporting Items for Systematic Review and Meta-Analyses (PRISMA) algorithm. The literature search was performed using variouscombinations of keywords. The statistical analysis was completed using Review Manager (RevMan), Version 5.3. RESULTS In the nineteen unique studies identified, there were 2,448 medial stabilized TKJRs implanted in 2,195 participants, there were 1,777 TKJRs with non-medial stabilized design constructs implanted in 1,734 subjects. The final mean Knee Society Score (KSS) value in the medial stabilized group was 89.92 compared to 90.76 in the non-medial stabilized group, with the final KSS mean value difference between the two groups was statistically significant and favored the non-medial stabilized group (SMD 0.21; 95% CI: 0.01 to 0.41; p = 004). The mean difference in the final WOMAC values between the two groups was also statistically significant and favored the medial stabilized group (SMD: -0.27; 95% CI: -0.47 to -0.07; p = 0.009). Moderate to high values (I2 ) of heterogeneity were observed during the statistical comparison of these functional outcomes. CONCLUSION Based on the small number of studies with appropriate statistical analysis, we are unable to reach a clear conclusion in the clinical performance of medial stabilized knee replacement construct. LEVEL OF EVIDENCE Level II.
Collapse
Affiliation(s)
- Tony Young
- Department of Surgery, University of Melbourne, St. Vincent’s Hospital Melbourne, Fitzroy, VIC, Australia
- Department of Orthopaedic Surgery, St. Vincent’s Hospital Melbourne, Fitzroy, VIC, Australia
| | - Michelle M. Dowsey
- Department of Surgery, University of Melbourne, St. Vincent’s Hospital Melbourne, Fitzroy, VIC, Australia
- Department of Orthopaedic Surgery, St. Vincent’s Hospital Melbourne, Fitzroy, VIC, Australia
| | - Marcus Pandy
- Department of Mechanical Engineering, Melbourne School of Engineering, University of Melbourne, Parkville, VIC, Australia
| | - Peter F. Choong
- Department of Surgery, University of Melbourne, St. Vincent’s Hospital Melbourne, Fitzroy, VIC, Australia
- Department of Orthopaedic Surgery, St. Vincent’s Hospital Melbourne, Fitzroy, VIC, Australia
| |
Collapse
|
36
|
Canham CD, Incavo SJ. The Medial Stabilized Knee Guides Knee Motion. Tech Orthop 2018. [DOI: 10.1097/bto.0000000000000262] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 11/25/2022]
|
37
|
Kono K, Tomita T, Futai K, Yamazaki T, Tanaka S, Yoshikawa H, Sugamoto K. In vivo three-dimensional kinematics of normal knees during different high-flexion activities. Bone Joint J 2018; 100-B:50-55. [PMID: 29305450 PMCID: PMC5842511 DOI: 10.1302/0301-620x.100b1.bjj-2017-0553.r2] [Citation(s) in RCA: 41] [Impact Index Per Article: 6.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 11/13/2022]
Abstract
Aims In Asia and the Middle-East, people often flex their knees deeply
in order to perform activities of daily living. The purpose of this
study was to investigate the 3D kinematics of normal knees during
high-flexion activities. Our hypothesis was that the femorotibial
rotation, varus-valgus angle, translations, and kinematic pathway
of normal knees during high-flexion activities, varied according
to activity. Materials and Methods We investigated the in vivo kinematics of eight
normal knees in four male volunteers (mean age 41.8 years; 37 to
53) using 2D and 3D registration technique, and modelled the knees
with a computer aided design program. Each subject squatted, kneeled,
and sat cross-legged. We evaluated the femoral rotation and varus-valgus
angle relative to the tibia and anteroposterior translation of the
medial and lateral side, using the transepicodylar axis as our femoral
reference relative to the perpendicular projection on to the tibial
plateau. This method evaluates the femur medially from what has
elsewhere been described as the extension facet centre, and differs
from the method classically applied. Results During squatting and kneeling, the knees displayed femoral external
rotation. When sitting cross-legged, femurs displayed internal rotation
from 10° to 100°. From 100°, femoral external rotation was observed.
No significant difference in varus-valgus angle was seen between
squatting and kneeling, whereas a varus position was observed from
140° when sitting cross-legged. The measure kinematic pathway using
our methodology found during squatting a medial pivoting pattern
from 0° to 40° and bicondylar rollback from 40° to 150°. During
kneeling, a medial pivot pattern was evident. When sitting cross-legged,
a lateral pivot pattern was seen from 0° to 100°, and a medial pivot
pattern beyond 100°. Conclusion The kinematics of normal knees during high flexion are variable
according to activity. Nevertheless, our study was limited to a
small number of male patients using a different technique to report
the kinematics than previous publications. Accordingly, caution
should be observed in generalizing our findings. Cite this article: Bone Joint J 2018;100-B:50–5.
Collapse
Affiliation(s)
- K Kono
- Graduate School of Medicine, The University of Tokyo, 7-3-1 Hongo, Bunkyo-ku, Tokyo 113-0033, Japan and Department of Orthopaedic Biomaterial Science, Osaka University Graduate School of Medicine, 2-2 Yamada-oka, Suita, Osaka 565-0871, Japan
| | - T Tomita
- Osaka University Graduate School of Medicine, 2-2 Yamada-oka, Suita, Osaka 565-0871, Japan
| | - K Futai
- Osaka University Graduate School of Medicine, 2-2 Yamada-oka, Suita, Osaka 565-0871, Japan
| | - T Yamazaki
- Saitama Institute of Technology, 1690 Fusaiji, Fukaya, Saitama 369-0293, Japan
| | - S Tanaka
- Graduate School of Medicine, The University of Tokyo, 7-3-1 Hongo, Bunkyo-ku, Tokyo 113-0033, Japan
| | - H Yoshikawa
- Osaka University Graduate School of Medicine, 2-2 Yamada-oka, Suita, Osaka 565-0871, Japan
| | - K Sugamoto
- Osaka University Graduate School of Medicine, 2-2 Yamada-oka, Suita, Osaka 565-0871, Japan
| |
Collapse
|
38
|
Sabatini L, Risitano S, Parisi G, Tosto F, Indelli PF, Atzori F, Massè A. Medial Pivot in Total Knee Arthroplasty: Literature Review and Our First Experience. CLINICAL MEDICINE INSIGHTS-ARTHRITIS AND MUSCULOSKELETAL DISORDERS 2018; 11:1179544117751431. [PMID: 29326531 PMCID: PMC5758963 DOI: 10.1177/1179544117751431] [Citation(s) in RCA: 41] [Impact Index Per Article: 6.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 09/13/2017] [Accepted: 12/07/2017] [Indexed: 01/26/2023]
Abstract
Background: Traditional total knee implants designs, usually, are not able to reproduce the physiological kinematics of the knee, leaving almost 20% of the patients, those who underwent a total knee arthroplasty (TKA), not fully satisfied. Modern inserts are nowadays designed with a fully congruent medial compartment to reproduce the normal medial pivoting biomechanics of the knee. The aim of this article was to evaluate preliminary clinical improvement using the Medial Congruent (MC) insert as specific level of constraint. Materials and methods: A total of 10 consecutive patients have been enrolled in this study and treated using an MC tibial polyethylene insert. The Oxford Knee Score (OKS) and the Knee Society Score (KSS) have been assessed preoperatively and at 3-month, 6-month, and 1-year follow-up (FU) and used as validated measurements to evaluate early clinical improvements. Postoperative radiological examination was reviewed looking for radiolucent lines or loosening of the components. Results: Average improvement in OKS was from 19.5 to 41.2, whereas KSS improved with an average score from 64.7 preoperatively to 167.5 at the final FU showing good to excellent results in 95% of the treated knees. Evaluating the range of motion, the average maximum active movement was 124° and none of the patients needing for a revision surgery or manipulation under anesthesia. No complications were observed at the final FU as septic or aseptic loosening or vascular or neurologic injury. Discussion and conclusions: Medial Congruent insert showed good to excellent clinical results at 1-year FU. Range of motion and subjective outcomes were satisfying and comparable with results obtained in literature using traditional TKA design.
Collapse
Affiliation(s)
- Luigi Sabatini
- Department of Orthopaedics and Traumatology, Città della Salute e della Scienza di Torino, CTO Hospital, Turin, Italy
| | | | | | | | - Pier Francesco Indelli
- Department of Orthopaedic Surgery, Stanford University School of Medicine, Palo Alto, CA, USA
| | | | - Alessandro Massè
- Department of Orthopaedics and Traumatology, Città della Salute e della Scienza di Torino, CTO Hospital, Turin, Italy
| |
Collapse
|
39
|
Van Overschelde P, Pinskerova V, Koch PP, Fornasieri C, Fucentese S. Redefining Knee Balance in a Medially Stabilized Prosthesis: An In-Vitro Study. Open Orthop J 2017; 11:1165-1172. [PMID: 29290852 PMCID: PMC5721310 DOI: 10.2174/1874325001711011165] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 06/27/2017] [Revised: 08/22/2017] [Accepted: 09/12/2017] [Indexed: 11/22/2022] Open
Abstract
BACKGROUND To date, there is still no consensus on what soft tissues must be preserved and what structures can be safely released during total knee arthroplasty (TKA) with a medially stabilized implant. OBJECTIVE The aim of this study was to analyze the effect of a progressive selective release of the medial and lateral soft tissues in a knee implanted with a medially stabilized prosthesis. METHOD Six cadaveric fresh-frozen full leg specimens were tested. In each case, kinematic pattern and mediolateral laxity were measured in three stages: firstly, prior to implantation; secondly, after the implantation of the trial components, but before any soft tissue release; and thirdly, progressively as soft tissue was released with the trial implant in place. The incremental impact of each selective release on knee balance was then analyzed. RESULTS In all cases sagittal stability was not affected by the progressive release of the lateral soft tissue envelope. It was possible to perform progressive lateral release provided the anterior one-third of the iliotibial band (ITB) remained intact. Progressive medial release could be performed on the medial side provided the anterior fibers of the superficial medial collateral ligament (sMCL) remained intact. CONCLUSION The medially conforming implant remains stable provided the anterior fibers of sMCL and the anterior fibers of the ITB remain intact. The implant's sagittal stability is mainly dependent on its medial ball-in-socket design.
Collapse
Affiliation(s)
| | - Vera Pinskerova
- Charles University, First Orthopaedic Clinic, Faculty of Medicine, Prague, Czech Republic
| | - Peter P. Koch
- Kantonsspital Winterthur, Klinik für Orthopädie und Traumatologie, Brauerstrasse 15, 8400 Winterthur, Switzerland
| | | | - Sandro Fucentese
- University Hospital Balgrist, Forchstrasse 340, 8008 Zürich, Switzerland
| |
Collapse
|
40
|
Ross DS, Howell SM, Hull ML. Errors in Calculating Anterior–Posterior Tibial Contact Locations in Total Knee Arthroplasty Using Three-Dimensional Model to Two-Dimensional Image Registration in Radiographs: An In Vitro Study of Two Methods. J Biomech Eng 2017; 139:2650611. [DOI: 10.1115/1.4037632] [Citation(s) in RCA: 7] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/10/2017] [Indexed: 11/08/2022]
Abstract
Knowledge of anterior–posterior (A-P) tibial contact locations provides an objective assessment of the relative motion of the tibia on the femur following total knee arthroplasty (TKA), which can be used to compare the effects of different components, surgical techniques, and alignment goals on knee function in vivo. Both the lowest point method and the penetration method have been used to calculate A-P tibial contact locations using three-dimensional (3D) model to two-dimensional (2D) image registration. The primary objective of this study was to quantify errors in calculating the A-P tibial contact location using the lowest point and penetration methods because the errors in calculating the A-P tibial contact locations using these two methods are unknown. The A-P tibial contact locations were calculated with the two methods and simultaneously measured with a tibial force sensor in ten fresh-frozen cadaveric knee specimens with a TKA. Single-plane radiographs of the knee specimens were acquired at 0 deg, 30 deg, 60 deg, and 90 deg of flexion in neutrally, internally, and externally rotated orientations. While the radiographs were exposed, reference A-P tibial contact locations were simultaneously collected using the tibial force sensor to be compared to the calculated A-P tibial contact locations. The overall root-mean-squared-errors (RMSEs) in the A-P tibial contact location calculated with the lowest point method, the penetration method with penetration, and penetration method without penetration were 5.5 mm, 3.6 mm, and 8.9 mm, respectively. The overall RMSE was lowest for the penetration method with penetration, making it the superior method for calculating A-P tibial contact locations.
Collapse
Affiliation(s)
- Derrick S. Ross
- Biomedical Engineering Graduate Group, University of California, Davis, Davis, CA 95616
| | - Stephen M. Howell
- Department of Biomedical Engineering, University of California, Davis, Davis, CA 95616
| | - Maury L. Hull
- Department of Mechanical and Aerospace Engineering, University of California, Davis, Davis, CA 95616
- Department of Biomedical Engineering, University of California, Davis, Davis, CA 95616
- Department of Orthopaedic Surgery, University of California, Davis, 1 Shields Avenue, Davis, CA, 95616 e-mail:
| |
Collapse
|
41
|
Risitano S, Indelli PF. Is "symmetric" gap balancing still the gold standard in primary total knee arthroplasty? ANNALS OF TRANSLATIONAL MEDICINE 2017; 5:325. [PMID: 28861422 DOI: 10.21037/atm.2017.06.18] [Citation(s) in RCA: 26] [Impact Index Per Article: 3.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 11/06/2022]
Abstract
A rectangular and symmetrical gap in flexion as well as in extension is mandatory to achieve good outcomes and good long-term results in total knee arthroplasty (TKA) using classical designs. Recently, as showed in several fluoroscopic studies, different modern designs (medial congruent or sagittally stable implants) have been demonstrated to better reproduce the more physiological medial pivoting (MP) biomechanics of the normal knee when compared to classical postero-stabilized (PS) and cruciate-retaining (CR) designs. These modern designs, characterized by different level of conformity, might require adopting a different surgical technique in terms of soft tissue balancing technique for primary TKA. In such cases, the current authors suggest to reproduce a slightly asymmetric extension and flexion gaps with a tighter medial then lateral compartment to re-establish the MP kinematics of the normal knee.
Collapse
Affiliation(s)
- Salvatore Risitano
- Department of Orthopaedic Surgery and Bioengineering, Stanford University School of Medicine and the Palo Alto Veterans Affairs Health Care System (PAVAHCS), Palo Alto, CA, USA.,Department of Orthopaedic Surgery and Traumatology, University of Turin, "Citta della scianza e della salute"-CTO Hospital of Turin, Turin, Italy
| | - Pier Francesco Indelli
- Department of Orthopaedic Surgery and Bioengineering, Stanford University School of Medicine and the Palo Alto Veterans Affairs Health Care System (PAVAHCS), Palo Alto, CA, USA
| |
Collapse
|