1
|
He Y, Xu Y, Hai M, Feng Y, Liu P, Chen Z, Duan W. Exoskeleton-Assisted Rehabilitation and Neuroplasticity in Spinal Cord Injury. World Neurosurg 2024; 185:45-54. [PMID: 38320651 DOI: 10.1016/j.wneu.2024.01.167] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/23/2023] [Revised: 01/29/2024] [Accepted: 01/30/2024] [Indexed: 02/08/2024]
Abstract
Spinal cord injury (SCI) results in neurological deficits below the level of injury, causing motor dysfunction and various severe multisystem complications. Rehabilitative training plays a crucial role in the recovery of individuals with SCI, and exoskeleton serves as an emerging and promising tool for rehabilitation, especially in promoting neuroplasticity and alleviating SCI-related complications. This article reviews the classifications and research progresses of medical exoskeletons designed for SCI patients and describes their performances in practical application separately. Meanwhile, we discuss their mechanisms for enhancing neuroplasticity and functional remodeling, as well as their palliative impacts on secondary complications. The potential trends in exoskeleton design are raised according to current progress and requirements on SCI rehabilitation.
Collapse
Affiliation(s)
- Yana He
- Department of Neurosurgery, Xuanwu Hospital, Capital Medical University, Beijing, China; School of Basic Medical Sciences, Capital Medical University, Beijing, China
| | - Yuxuan Xu
- Department of Neurosurgery, Xuanwu Hospital, Capital Medical University, Beijing, China; School of Basic Medical Sciences, Capital Medical University, Beijing, China
| | - Minghang Hai
- Department of Neurosurgery, Xuanwu Hospital, Capital Medical University, Beijing, China; School of Basic Medical Sciences, Capital Medical University, Beijing, China
| | - Yang Feng
- Department of Neurosurgery, Xuanwu Hospital, Capital Medical University, Beijing, China; School of Basic Medical Sciences, Capital Medical University, Beijing, China
| | - Penghao Liu
- Department of Neurosurgery, Xuanwu Hospital, Capital Medical University, Beijing, China; Lab of Spinal Cord Injury and Functional Reconstruction, China International Neuroscience Institute(CHINA-INI), Beijing, China
| | - Zan Chen
- Department of Neurosurgery, Xuanwu Hospital, Capital Medical University, Beijing, China; Lab of Spinal Cord Injury and Functional Reconstruction, China International Neuroscience Institute(CHINA-INI), Beijing, China
| | - Wanru Duan
- Department of Neurosurgery, Xuanwu Hospital, Capital Medical University, Beijing, China; Lab of Spinal Cord Injury and Functional Reconstruction, China International Neuroscience Institute(CHINA-INI), Beijing, China.
| |
Collapse
|
2
|
Postol N, Barton J, Wakely L, Bivard A, Spratt NJ, Marquez J. "Are we there yet?" expectations and experiences with lower limb robotic exoskeletons: a qualitative evaluation of the therapist perspective. Disabil Rehabil 2024; 46:1023-1030. [PMID: 36861846 DOI: 10.1080/09638288.2023.2183992] [Citation(s) in RCA: 2] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/28/2022] [Revised: 02/11/2023] [Accepted: 02/18/2023] [Indexed: 03/03/2023]
Abstract
PURPOSE Lower limb robotic exoskeletons can assist movement, however, clinical uptake in neurorehabilitation is limited. The views and experiences of clinicians are pivotal to the successful clinical implementation of emerging technologies. This study investigates therapist perspectives of the clinical use and future role of this technology in neurorehabilitation. METHODS Australian and New Zealand-based therapists with lower limb exoskeleton experience were recruited to complete an online survey and semi-structured interview. Survey data were transposed into tables and interviews transcribed verbatim. Qualitative data collection and analysis were guided by qualitative content analysis and interview data were thematically analysed. RESULTS Five participants revealed that the use of exoskeletons to deliver therapy involves the interplay of human elements - experiences and perspectives of use, and mechanical elements - the device itself. Two overarching themes emerged: the "journey", with subthemes of clinical reasoning and user experience; and the "vehicle" with design features and cost as subthemes, to explore the question "Are we there yet?" CONCLUSION Therapists expressed positive and negative perspectives from their experiences with exoskeletons, giving suggestions for design features, marketing input, and cost to enhance future use. Therapists are optimistic that this journey will see lower limb exoskeletons integral to rehabilitation service delivery.
Collapse
Affiliation(s)
- Nicola Postol
- University of Newcastle, College of Health, Medicine and Wellbeing, Callghan, Australia
- Centre for Brain and Mental Health, Hunter Medical Research Institute, New Lambton, Australia
| | - Julia Barton
- University of Newcastle, College of Health, Medicine and Wellbeing, Callghan, Australia
| | - Luke Wakely
- Department of Rural Health, University of Newcastle, Callghan, Australia
- Hunter New England Local Health District, New Lambton, Australia
| | - Andrew Bivard
- University of Newcastle, College of Health, Medicine and Wellbeing, Callghan, Australia
- Centre for Brain and Mental Health, Hunter Medical Research Institute, New Lambton, Australia
- University of Melbourne, School of Medicine, Dentistry and Public Health, Melbourne, Australia
| | - Neil J Spratt
- University of Newcastle, College of Health, Medicine and Wellbeing, Callghan, Australia
- Centre for Brain and Mental Health, Hunter Medical Research Institute, New Lambton, Australia
- Hunter New England Local Health District, New Lambton, Australia
| | - Jodie Marquez
- University of Newcastle, College of Health, Medicine and Wellbeing, Callghan, Australia
- Centre for Brain and Mental Health, Hunter Medical Research Institute, New Lambton, Australia
| |
Collapse
|
3
|
Xu J, Xue Y, Yu Z, Zhao D, Li X, Fan J, Han D. Effect of exoskeleton manipulator on hand function rehabilitation for postburn patients. Disabil Rehabil 2023; 45:4148-4155. [PMID: 36373170 DOI: 10.1080/09638288.2022.2143577] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/21/2022] [Accepted: 10/30/2022] [Indexed: 11/15/2022]
Abstract
PURPOSE Patients with scar contracture deformities caused by hand burns were treated with an exoskeleton manipulator system, which was equipped with games to explore its clinical application value. METHODS Twenty patients who were treated for post-burn scars of bilateral hands between October 2020 and June 2021 were selected (ChiCTR2000036232). The patients were divided into two groups: control, 10 patients (traditional outpatient treatment); and experimental, 10 patients (exoskeleton manipulator system treatment). We compared the change in the total active motion (TAM) value, grip strength, scar improvement, and postoperative pain improvement. RESULTS After 3 months of rehabilitation training, the improvement of thumb TAM was 33.80 ± 11.38 ° in the experimental group and 23.2 ± 6.13 ° in the control group. With respect to the index finger TAM, the improvement in the experimental and control groups was 84.50 ± 30.96 ° and 54.80 ± 15.89 °, respectively. The middle finger TAM of the experimental and control groups improved by 86.75 ± 32.85 ° and 60.25 ± 17.97 °, respectively. However, improvement of grip strength, scar score, and pain score were similar between the two groups. CONCLUSIONS The exoskeleton manipulator system has excellent effects in improving burned hand joint movement, which is suitable for hand burn patients and has beneficial clinical effects.Implications for rehabilitationExercise is an effective means to improve the hand function of burn patients.The application of mechanical devices in the rehabilitation of burned hands can effectively help patients exercise.The A5 Hand Function Training System is an exoskeleton mechanical device that can exercise the small joints of the hand. It assists patients in using different computer games during treatment.
Collapse
Affiliation(s)
- Jia Xu
- Department of Plastic and Reconstructive Surgery, Shanghai Ninth People's Hospital, Shanghai Jiao Tong University School of Medicine, Shanghai, People's Republic of China
| | - Yaxin Xue
- Department of Plastic and Reconstructive Surgery, Shanghai Ninth People's Hospital, Shanghai Jiao Tong University School of Medicine, Shanghai, People's Republic of China
| | - Zhencheng Yu
- Department of Plastic and Reconstructive Surgery, Shanghai Ninth People's Hospital, Shanghai Jiao Tong University School of Medicine, Shanghai, People's Republic of China
| | - Danyang Zhao
- Department of Plastic and Reconstructive Surgery, Shanghai Ninth People's Hospital, Shanghai Jiao Tong University School of Medicine, Shanghai, People's Republic of China
| | - Xin Li
- Department of Plastic and Reconstructive Surgery, Shanghai Ninth People's Hospital, Shanghai Jiao Tong University School of Medicine, Shanghai, People's Republic of China
| | - Jiajun Fan
- Department of Plastic and Reconstructive Surgery, Shanghai Ninth People's Hospital, Shanghai Jiao Tong University School of Medicine, Shanghai, People's Republic of China
| | - Dong Han
- Department of Plastic and Reconstructive Surgery, Shanghai Ninth People's Hospital, Shanghai Jiao Tong University School of Medicine, Shanghai, People's Republic of China
| |
Collapse
|
4
|
Mitchell J, Shirota C, Clanchy K. Factors that influence the adoption of rehabilitation technologies: a multi-disciplinary qualitative exploration. J Neuroeng Rehabil 2023; 20:80. [PMID: 37340496 DOI: 10.1186/s12984-023-01194-9] [Citation(s) in RCA: 3] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/01/2022] [Accepted: 05/23/2023] [Indexed: 06/22/2023] Open
Abstract
BACKGROUND Technological innovation is recognised as having the potential to enhance rehabilitation for people with disability. Yet, resistance to, and abandonment of, rehabilitation technology is prevalent and the successful translation of technology into rehabilitation settings remains limited. Therefore, the aim of this work was to develop an in-depth, multi-stakeholder perspective on what influences the adoption of rehabilitation technologies. METHODS Semi-structured focus groups were conducted as part of a larger research project aiming to facilitate the co-design of a novel neurorestorative technology. Focus group data were analysed using a five-phase hybrid deductive-inductive approach to qualitative data analysis. RESULTS Focus groups were attended by 43 stakeholders with expertise in one or more of the following fields: people with disability, allied health, human movement science, computer science, design, engineering, ethics, funding, marketing, business, product development, and research development. Six main themes influencing the adoption of technology in rehabilitation were identified: cost beyond the purchase price, benefits to all stakeholders, trust to be earned in technology, ease of technology operation, ability to access technology, and the 'co' in co-design. All six themes were found to be interrelated; in particular, the importance of direct stakeholder engagement in the development of rehabilitation technologies (the 'co' in co-design) was prevalent in all themes. CONCLUSIONS A range of complex and interrelated factors influence the adoption of rehabilitation technologies. Importantly, many of the issues that have the potential to negatively impact rehabilitation technology adoption may be addressed during development by utilising the experience and expertise of stakeholders who influence its supply and demand. Our findings state that a wider cohort of stakeholders needs to be actively engaged in the development of rehabilitation technologies to better address the factors that contribute to technology underutilisation and abandonment and facilitate better outcomes for people with disability.
Collapse
Affiliation(s)
- Jessie Mitchell
- The Hopkins Centre, Menzies Health Institute Queensland, Griffith University, Brisbane, Australia
| | - Camila Shirota
- The Hopkins Centre, Menzies Health Institute Queensland, Griffith University, Brisbane, Australia
| | - Kelly Clanchy
- The Hopkins Centre, Menzies Health Institute Queensland, Griffith University, Brisbane, Australia.
- School of Health Sciences and Social Work, Griffith University, Southport, Australia.
| |
Collapse
|
5
|
Morone G, Pirrera A, Iannone A, Giansanti D. Development and Use of Assistive Technologies in Spinal Cord Injury: A Narrative Review of Reviews on the Evolution, Opportunities, and Bottlenecks of Their Integration in the Health Domain. Healthcare (Basel) 2023; 11:healthcare11111646. [PMID: 37297786 DOI: 10.3390/healthcare11111646] [Citation(s) in RCA: 2] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/03/2023] [Revised: 05/15/2023] [Accepted: 05/26/2023] [Indexed: 06/12/2023] Open
Abstract
Assistive technologies are increasingly taking a leading role in supporting people with spinal cord injury (SCI). This narrative review of reviews intends to contribute by making a map point investigating the integration of ATs in SCI. The methodology of the review was based on: (I) a search of PubMed and Scopus and (II) an eligibility assessment using specific parameters. The outcome highlighted the following: -The evolution of ATs considered in the context of SCI, considering ATs as both products and/or services in standalone and/or networked devices, and as processes of delivery. -Innovative technologies could play an important role in improving the quality of life and in minimizing costs in healthcare. -The international scientific community has identified ATs as one of the six strategic development areas in SCI. The overview also allowed the detection of some problems: (I) The ethical and regulatory aspects have been addressed in a weak way and only in specific and limited cases. (II) There is a lack of studies on the use and applications of ATs in SCI with a focus in multiple domains (e.g., costs, acceptance, dissemination, problems, regulatory aspects, ethical aspects, and other issues important for integration into the health domain). This review highlights the need for further studies and activities focused on integrating consensus in multiple domains, including ethics and regulations, to aid researchers and decision-makers in the field.
Collapse
Affiliation(s)
- Giovanni Morone
- Department of Life, Health and Environmental Sciences, University of L'Aquila, 67100 L'Aquila, Italy
- San Raffaele Institute of Sulmona, 67039 Sulmona, Italy
| | | | - Antonio Iannone
- Association "Relazionarti", 05100 Terni, Italy
- CREA Italian National Research Body, 00184 Roma, Italy
| | | |
Collapse
|
6
|
Cumplido-Trasmonte C, Molina-Rueda F, Puyuelo-Quintana G, Plaza-Flores A, Hernández-Melero M, Barquín-Santos E, Destarac-Eguizabal MA, García-Armada E. Satisfaction analysis of overground gait exoskeletons in people with neurological pathology. a systematic review. J Neuroeng Rehabil 2023; 20:47. [PMID: 37072823 PMCID: PMC10111693 DOI: 10.1186/s12984-023-01161-4] [Citation(s) in RCA: 1] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/28/2022] [Accepted: 03/30/2023] [Indexed: 04/20/2023] Open
Abstract
BACKGROUND People diagnosed with neurological pathology may experience gait disorders that affect their quality of life. In recent years, research has been carried out on a variety of exoskeletons in this population. However, the satisfaction perceived by the users of these devices is not known. Therefore, the objective of the present study is to evaluate the satisfaction perceived by users with neurological pathology (patients and professionals) after the use of overground exoskeletons. METHODS A systematic search of five electronic databases was conducted. In order to be included in this review for further analysis, the studies had to meet the following criteria: [1] the study population was people diagnosed with neurological pathology; [2] the exoskeletons had to be overground and attachable to the lower limbs; and [3]: the studies were to include measures assessing either patient or therapist satisfaction with the exoskeletons. RESULTS Twenty-three articles were selected, of which nineteen were considered clinical trials. Participants diagnosed with stroke (n = 165), spinal cord injury (SCI) (n = 102) and multiple sclerosis (MS) (n = 68). Fourteen different overground exoskeleton models were analysed. Fourteen different methods of assessing patient satisfaction with the devices were found, and three ways to evaluate it in therapists. CONCLUSION Users' satisfaction with gait overground exoskeletons in stroke, SCI and MS seems to show positive results in safety, efficacy and comfort of the devices. However, the worst rated aspects and therefore those that should be optimized from the users' point of view are ease of adjustment, size and weight, and ease of use.
Collapse
Affiliation(s)
- C Cumplido-Trasmonte
- Centre for Automation and Robotics (CAR), CSIC-UPM, Ctra Campo Real km 0.2 - La Poveda- Arganda del Rey, Madrid, 28500, Spain.
- International Doctoral School, Rey Juan Carlos University, Madrid, 28922, Spain.
| | - F Molina-Rueda
- Department of Physical Therapy, Physical Medicine and Rehabilitation, Rey Juan Carlos University, Madrid, Spain
| | - G Puyuelo-Quintana
- International Doctoral School, Rey Juan Carlos University, Madrid, 28922, Spain
- Marsi Bionics S.L., Madrid, Spain
| | - A Plaza-Flores
- Centre for Automation and Robotics (CAR), CSIC-UPM, Ctra Campo Real km 0.2 - La Poveda- Arganda del Rey, Madrid, 28500, Spain
- Marsi Bionics S.L., Madrid, Spain
- Polytechnic University of Madrid, Madrid, Spain
| | - M Hernández-Melero
- Centre for Automation and Robotics (CAR), CSIC-UPM, Ctra Campo Real km 0.2 - La Poveda- Arganda del Rey, Madrid, 28500, Spain
| | | | | | - E García-Armada
- Centre for Automation and Robotics (CAR), CSIC-UPM, Ctra Campo Real km 0.2 - La Poveda- Arganda del Rey, Madrid, 28500, Spain.
| |
Collapse
|
7
|
van Dijsseldonk RB, Vriezekolk JE, Keijsers NLW, Geurts ACH, van Nes IJW. Needs and wishes for the future lower limb exoskeleton: an interview study among people with spinal cord injury with community-based exoskeleton experience. Disabil Rehabil 2023; 45:1139-1146. [PMID: 35332808 DOI: 10.1080/09638288.2022.2055158] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/03/2022]
Abstract
PURPOSE Exoskeleton use by people with complete spinal cord injury (SCI) in daily life is challenging. To optimize daily exoskeleton use, a better understanding of the purpose of use and the accompanying improvements are needed. The perspective of experienced exoskeleton users could guide design improvements. METHODS Face-to-face semi-structured interviews were held with 13 people with SCI with exoskeleton experience. Interviews were audio-taped, transcribed, and analysed thematically. RESULTS Participants expressed three future purposes of exoskeleton use: for daily activities (e.g., stair climbing), exercise (e.g., staying healthy), and social interaction (e.g., standing at parties). Exoskeleton use during daily activities was the ultimate goal. Therefore, the future exoskeleton should be: easy to use, small and lightweight, tailor made, safe, comfortable, less distinctive, durable, and affordable. Improving the ease of use was relevant for all purposes, for all participants. The other suggestions for improvement varied depending on the purpose of use and the participant. CONCLUSION Increasingly more advanced improvements are needed to transition from an exercise purpose to social interaction, and ultimately use during daily activities. In the current study, detailed suggestions for improvements have been made. Only when multiple of these suggestions are adjusted, can the exoskeleton be used to its full potential.IMPLICATIONS FOR REHABILITATIONThe use of an exoskeleton by people with a complete spinal cord injury in daily life is still in its infancy.To optimize daily exoskeleton use, a better understanding of the purpose of use and exoskeleton improvements is needed.More advanced improvements to future exoskeletons are needed to make a transition from use as an exercise device to use during social interaction and daily activities.Improving the ease of use of future exoskeletons is considered a priority by experienced users, followed by making the exoskeleton small, lightweight, and tailor made.
Collapse
Affiliation(s)
- Rosanne B van Dijsseldonk
- Department of Rehabilitation, Donders Institute for Brain, Cognition and Behaviour, Radboud University Medical Center, Nijmegen, Netherlands
- Department of Research, Sint Maartenskliniek, Nijmegen, Netherlands
| | | | - Noël L W Keijsers
- Department of Rehabilitation, Donders Institute for Brain, Cognition and Behaviour, Radboud University Medical Center, Nijmegen, Netherlands
- Department of Research, Sint Maartenskliniek, Nijmegen, Netherlands
| | - Alexander C H Geurts
- Department of Rehabilitation, Donders Institute for Brain, Cognition and Behaviour, Radboud University Medical Center, Nijmegen, Netherlands
- Department of Rehabilitation, Sint Maartenskliniek, Nijmegen, Netherlands
| | - Ilse J W van Nes
- Department of Rehabilitation, Sint Maartenskliniek, Nijmegen, Netherlands
| |
Collapse
|
8
|
Bigford GE, Garshick E. Systemic inflammation after spinal cord injury: A review of biological evidence, related health risks, and potential therapies. Curr Opin Pharmacol 2022; 67:102303. [PMID: 36206621 PMCID: PMC9929918 DOI: 10.1016/j.coph.2022.102303] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/01/2022] [Accepted: 09/06/2022] [Indexed: 01/25/2023]
Abstract
Individuals with chronic traumatic spinal cord injury (SCI) develop progressive multi-system health problems that result in clinical illness and disability. Systemic inflammation is associated with many of the common medical complications and acquired diseases that accompany chronic SCI, suggesting that it contributes to a number of comorbid pathological conditions. However, many of the mechanisms that promote persistent systemic inflammation and its consequences remain ill-defined. This review describes the significant biological factors that contribute to systemic inflammation, major organ systems affected, health risks, and the potential treatment strategies. We aim to highlight the need for a better understanding of inflammatory processes, and to establish appropriate strategies to address inflammation in SCI.
Collapse
Affiliation(s)
- Gregory E Bigford
- Department of Neurological Surgery, University of Miami Miller School of Medicine, Miami, FL, USA.
| | - Eric Garshick
- Pulmonary, Allergy, Sleep, and Critical Care Medicine Section, VA Boston Healthcare System, Boston, MA, USA; Harvard Medical School, Boston, MA, USA
| |
Collapse
|
9
|
Livolsi C, Conti R, Guanziroli E, Friðriksson Þ, Alexandersson Á, Kristjánsson K, Esquenazi A, Molino Lova R, Romo D, Giovacchini F, Crea S, Molteni F, Vitiello N. An impairment-specific hip exoskeleton assistance for gait training in subjects with acquired brain injury: a feasibility study. Sci Rep 2022; 12:19343. [PMID: 36369462 PMCID: PMC9652374 DOI: 10.1038/s41598-022-23283-w] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/29/2022] [Accepted: 10/27/2022] [Indexed: 11/13/2022] Open
Abstract
This study was designed to investigate the feasibility and the potential effects on walking performance of a short gait training with a novel impairment-specific hip assistance (iHA) through a bilateral active pelvis orthosis (APO) in patients with acquired brain injury (ABI). Fourteen subjects capable of independent gait and exhibiting mild-to-moderate gait deficits, due to an ABI, were enrolled. Subjects presenting deficit in hip flexion and/or extension were included and divided into two groups based on the presence (group A, n = 6) or absence (group B, n = 8) of knee hyperextension during stance phase of walking. Two iHA-based profiles were developed for the groups. The protocol included two overground gait training sessions using APO, and two evaluation sessions, pre and post training. Primary outcomes were pre vs. post-training walking distance and steady-state speed in the 6-min walking test. Secondary outcomes were self-selected speed, joint kinematics and kinetics, gait symmetry and forward propulsion, assessed through 3D gait analysis. Following the training, study participants significantly increased the walked distance and average steady-state speed in the 6-min walking tests, both when walking with and without the APO. The increased walked distance surpassed the minimal clinically important difference for groups A and B, (respectively, 42 and 57 m > 34 m). In group A, five out of six subjects had decreased knee hyperextension at the post-training session (on average the peak of the knee extension angle was reduced by 36%). Knee flexion during swing phase increased, by 16% and 31%, for A and B groups respectively. Two-day gait training with APO providing iHA was effective and safe in improving walking performance and knee kinematics in ABI survivors. These preliminary findings suggest that this strategy may be viable for subject-specific post-ABI gait rehabilitation.
Collapse
Affiliation(s)
- Chiara Livolsi
- The BioRobotics Institute, Scuola Superiore Sant'Anna, Pontedera, Pisa, Italy.
- Department of Excellence in Robotics & AI, Scuola Superiore Sant'Anna, Pisa, Italy.
| | | | - Eleonora Guanziroli
- Villa Beretta Rehabilitation Center, Valduce Hospital, Costa Masnaga, Lecco, Italy
| | | | | | | | - Alberto Esquenazi
- Department of PM&R, MossRehab and Einstein Healthcare Network, Elkins Park, PA, USA
| | | | | | | | - Simona Crea
- The BioRobotics Institute, Scuola Superiore Sant'Anna, Pontedera, Pisa, Italy
- Department of Excellence in Robotics & AI, Scuola Superiore Sant'Anna, Pisa, Italy
- IRCCS Fondazione Don Carlo Gnocchi ONLUS, Florence, Italy
| | - Franco Molteni
- Villa Beretta Rehabilitation Center, Valduce Hospital, Costa Masnaga, Lecco, Italy
| | - Nicola Vitiello
- The BioRobotics Institute, Scuola Superiore Sant'Anna, Pontedera, Pisa, Italy
- Department of Excellence in Robotics & AI, Scuola Superiore Sant'Anna, Pisa, Italy
- IRCCS Fondazione Don Carlo Gnocchi ONLUS, Florence, Italy
| |
Collapse
|
10
|
Rodriguez Tapia G, Doumas I, Lejeune T, Previnaire JG. Wearable powered exoskeletons for gait training in tetraplegia: a systematic review on feasibility, safety and potential health benefits. Acta Neurol Belg 2022; 122:1149-1162. [DOI: 10.1007/s13760-022-02011-1] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/21/2022] [Accepted: 06/16/2022] [Indexed: 11/01/2022]
|
11
|
Lamberti G, Sesenna G, Marina M, Ricci E, Ciardi G. Robot Assisted Gait Training in a Patient with Ataxia. Neurol Int 2022; 14:561-573. [PMID: 35893280 PMCID: PMC9326713 DOI: 10.3390/neurolint14030045] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/07/2022] [Revised: 06/17/2022] [Accepted: 06/20/2022] [Indexed: 12/02/2022] Open
Abstract
Background: Ataxia is a neurological sign characterized by motor coordination during gait/voluntary limb movements impairment. Ataxic gait leads to disability and worsening of quality of life; physiotherapy intervention is recommended to improve motor function. Recent studies showed benefits due to repetitive robotized assisted gait training using a static exoskeleton in patients affected by acquired ataxias. The aim of the study was to perform a preliminary evaluation of the short-term effects of overground UAN.GO®-assisted gait training in an adult patient with ataxia but with no clear genetic pattern. Methods: This case report study was conducted on a single male adult patient, who presented ataxic spastic gait, posterior chain tightness, pes cavus, and unstable standing position. The patient underwent two preliminary sessions to take part in the study. Treatment protocol planned 10 sessions and each one lasted 80 min, 60 of which were spent in gait training using the mobile overground exoskeleton UAN.GO®. At T1 (start of the study) and T10 (final evaluation) assessments using the Scale for the Assessment and Rating of Ataxia, Berg Balance Scale, 6-Minute Walking Test, and Likert Scale were administered. Space-time parameters of gait cycle were also evaluated: left and right step length, stance and swing percentages. Results: improvements on the Scale for the Assessment and Rating of Ataxia, Berg Balance Scale, and in the distance travelled at 6-Minute Walking Test emerged. The patient gave a positive opinion towards the treatment, showed by Likert Scale results. Kinematic gait analysis showed more physiological step length, stance and swing percentages, joint angles. The patient completed the training program with an excellent compliance. Discussion: Since these encouraging outcomes were obtained, it is possible to consider robot-assisted gait training performed with UAN.GO® as a therapeutic option to improve motor and functional performance in patients with ataxic gait.
Collapse
Affiliation(s)
- Gianfranco Lamberti
- Spinal Unit, Azienda Usl, 29121 Piacenza, Italy; (G.L.); (E.R.)
- Degree Course of Physiotherapy, University of Parma-Piacenza Training Center, Viale Abruzzo 12, 29017 Fiorenzuola d’Arda, Italy
| | | | - Martina Marina
- Degree Course of Physiotherapy Student, University of Parma-Piacenza Training Center, Viale Abruzzo 12, 29017 Fiorenzuola d’Arda, Italy;
| | - Emanuela Ricci
- Spinal Unit, Azienda Usl, 29121 Piacenza, Italy; (G.L.); (E.R.)
- Degree Course of Physiotherapy, University of Parma-Piacenza Training Center, Viale Abruzzo 12, 29017 Fiorenzuola d’Arda, Italy
| | - Gianluca Ciardi
- Spinal Unit, Azienda Usl, 29121 Piacenza, Italy; (G.L.); (E.R.)
- Degree Course of Physiotherapy, University of Parma-Piacenza Training Center, Viale Abruzzo 12, 29017 Fiorenzuola d’Arda, Italy
- Correspondence:
| |
Collapse
|
12
|
Maggio MG, Naro A, De Luca R, Latella D, Balletta T, Caccamo L, Pioggia G, Bruschetta D, Calabrò RS. Body Representation in Patients with Severe Spinal Cord Injury: A Pilot Study on the Promising Role of Powered Exoskeleton for Gait Training. J Pers Med 2022; 12:jpm12040619. [PMID: 35455735 PMCID: PMC9030625 DOI: 10.3390/jpm12040619] [Citation(s) in RCA: 9] [Impact Index Per Article: 4.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/27/2022] [Revised: 04/05/2022] [Accepted: 04/08/2022] [Indexed: 12/15/2022] Open
Abstract
Patients with spinal cord injury (SCI) complain of changes in body representation, potentially leading to negative physical and psychological consequences. The purpose of our study is to evaluate the effects of robotic training with the Ekso-GT on body representation (BR) and on the quality of life in patients with SCI. The trial was designed as a pilot, assessor-blinded study. Forty-two inpatients with a diagnosis of SCI, classified as either American Spinal Cord Injury Association Impairment Scale (AIS), were enrolled in this study and randomized into either a control (CG: n = 21) or an experimental (EG: n = 21) group. Patients in the EG received rehabilitation training with the Ekso-GT device, whereas the CG patients were trained with conventional physical therapy (CPT), which consisted of physical and occupational therapy and psychological support. We considered as a primary outcome the modified Body Uneasiness Test (MBUT), focusing on three specific subscales on the patient’s perception of BR, i.e., the Global Severity Index (MBUT-GSI), which is an indicator of body suffering; the Positive Symptom Distress Index (MBUT-PSDI) that expresses an individual’s psychological distress; and the Lower Limb MBUT (MBUT-LL), which indicates the subject’s perception of their thighs/legs. The Short-Form-12 Health Status Questionnaire (SF12) and the Beck’s Depression Inventory (BDI) were used as secondary outcomes to evaluate the effect of the training on the quality of life and the psychological status. Non-parametric statistical analysis showed that the effect of the two treatments was significantly different on MBUT (BR), SF-12 (quality of life), and, partially, BDI (mood). Particularly, patients belonging to the EG achieved a major improvement in nearly all test scores compared to those in the CG. Our data suggest that the Ekso-GT training could be helpful in achieving positive changes in BR in patients with chronic SCI, especially in reducing psychological distress (PSDI) and thigh/leg perception (MBUT-LL) with an overall improvement in quality of life (SF-12).
Collapse
Affiliation(s)
- Maria Grazia Maggio
- Department of Biomedical and Biotechnological Science, University of Catania, 95123 Catania, Italy;
| | - Antonino Naro
- AOU Policlinico “G. Martino”, 98125 Messina, Italy; (A.N.); (D.B.)
| | - Rosaria De Luca
- IRCCS Centro Neurolesi “Bonino Pulejo”, 98121 Messina, Italy; (R.D.L.); (D.L.); (T.B.)
| | - Desiree Latella
- IRCCS Centro Neurolesi “Bonino Pulejo”, 98121 Messina, Italy; (R.D.L.); (D.L.); (T.B.)
| | - Tina Balletta
- IRCCS Centro Neurolesi “Bonino Pulejo”, 98121 Messina, Italy; (R.D.L.); (D.L.); (T.B.)
| | - Lory Caccamo
- Neuropsychology Unit, University of Padua, 35121 Padua, Italy;
| | - Giovanni Pioggia
- Institute for Biomedical Research and Innovation, National Research Council of Italy (IRIB-CNR), 98164 Messina, Italy;
| | | | - Rocco Salvatore Calabrò
- IRCCS Centro Neurolesi “Bonino Pulejo”, 98121 Messina, Italy; (R.D.L.); (D.L.); (T.B.)
- Correspondence: ; Tel.: +39-090-6012-3850
| |
Collapse
|
13
|
Tamburella F, Lorusso M, Tramontano M, Fadlun S, Masciullo M, Scivoletto G. Overground robotic training effects on walking and secondary health conditions in individuals with spinal cord injury: systematic review. J Neuroeng Rehabil 2022; 19:27. [PMID: 35292044 PMCID: PMC8922901 DOI: 10.1186/s12984-022-01003-9] [Citation(s) in RCA: 12] [Impact Index Per Article: 6.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/05/2021] [Accepted: 02/14/2022] [Indexed: 12/12/2022] Open
Abstract
Overground powered lower limb exoskeletons (EXOs) have proven to be valid devices in gait rehabilitation in individuals with spinal cord injury (SCI). Although several articles have reported the effects of EXOs in these individuals, the few reviews available focused on specific domains, mainly walking. The aim of this systematic review is to provide a general overview of the effects of commercial EXOs (i.e. not EXOs used in military and industry applications) for medical purposes in individuals with SCI. This systematic review was conducted following the PRISMA guidelines and it referred to MED-LINE, EMBASE, SCOPUS, Web of Science and Cochrane library databases. The studies included were Randomized Clinical Trials (RCTs) and non-RCT based on EXOs intervention on individuals with SCI. Out of 1296 studies screened, 41 met inclusion criteria. Among all the EXO studies, the Ekso device was the most discussed, followed by ReWalk, Indego, HAL and Rex devices. Since 14 different domains were considered, the outcome measures were heterogeneous. The most investigated domain was walking, followed by cardiorespiratory/metabolic responses, spasticity, balance, quality of life, human–robot interaction, robot data, bowel functionality, strength, daily living activity, neurophysiology, sensory function, bladder functionality and body composition/bone density domains. There were no reports of negative effects due to EXOs trainings and most of the significant positive effects were noted in the walking domain for Ekso, ReWalk, HAL and Indego devices. Ekso studies reported significant effects due to training in almost all domains, while this was not the case with the Rex device. Not a single study carried out on sensory functions or bladder functionality reached significance for any EXO. It is not possible to draw general conclusions about the effects of EXOs usage due to the lack of high-quality studies as addressed by the Downs and Black tool, the heterogeneity of the outcome measures, of the protocols and of the SCI epidemiological/neurological features. However, the strengths and weaknesses of EXOs are starting to be defined, even considering the different types of adverse events that EXO training brought about. EXO training showed to bring significant improvements over time, but whether its effectiveness is greater or less than conventional therapy or other treatments is still mostly unknown. High-quality RCTs are necessary to better define the pros and cons of the EXOs available today. Studies of this kind could help clinicians to better choose the appropriate training for individuals with SCI.
Collapse
Affiliation(s)
- Federica Tamburella
- I.R.C.C.S. Santa Lucia Foundation (FSL), Via Ardeatina, 306, 00179, Rome, Italy.
| | - Matteo Lorusso
- I.R.C.C.S. Santa Lucia Foundation (FSL), Via Ardeatina, 306, 00179, Rome, Italy
| | - Marco Tramontano
- I.R.C.C.S. Santa Lucia Foundation (FSL), Via Ardeatina, 306, 00179, Rome, Italy
| | - Silvia Fadlun
- I.R.C.C.S. Santa Lucia Foundation (FSL), Via Ardeatina, 306, 00179, Rome, Italy
| | - Marcella Masciullo
- I.R.C.C.S. Santa Lucia Foundation (FSL), Via Ardeatina, 306, 00179, Rome, Italy
| | - Giorgio Scivoletto
- I.R.C.C.S. Santa Lucia Foundation (FSL), Via Ardeatina, 306, 00179, Rome, Italy
| |
Collapse
|
14
|
Apra C, Serra M, Robert H, Carpentier A. Early rehabilitation using gait exoskeletons is possible in the neurosurgical setting, even in patients with cognitive impairment. Neurochirurgie 2022; 68:458-460. [DOI: 10.1016/j.neuchi.2021.12.010] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/10/2021] [Accepted: 12/14/2021] [Indexed: 10/18/2022]
|
15
|
Koyama S, Tanabe S, Gotoh T, Taguchi Y, Katoh M, Saitoh E, Otaka Y, Hirano S. Wearable Power-Assist Locomotor for Gait Reconstruction in Patients With Spinal Cord Injury: A Retrospective Study. Front Neurorobot 2022; 16:775724. [PMID: 35250528 PMCID: PMC8894852 DOI: 10.3389/fnbot.2022.775724] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/14/2021] [Accepted: 01/11/2022] [Indexed: 11/16/2022] Open
Abstract
Wearable robotic exoskeletons (WREs) have been developed from orthoses as assistive devices for gait reconstruction in patients with spinal cord injury. They can solve some problems encountered with orthoses, such as difficulty in independent walking and standing up and high energy consumption during walking. The Wearable Power-Assist Locomotor (WPAL), a WRE, was developed based on a knee–ankle–foot orthosis with a single medial hip joint. The WPAL has been updated seven times during the period from the beginning of its development, in 2005, to 2020. The latest version, launched as a commercialized model in 2016, is available for medical facilities. In this retrospective study, which included updated results from previous reports, all data were extracted from development research records from July 2007 to December 2020. The records were as follows: patient characteristics [the number of participants, injury level, and the American Spinal Injury Association Impairment Scale (AIS) score], the total number of WPAL trials when aggregating the cases with all the versions or only the latest version of the WPAL, and maximum walking performance (functional ambulation category [FAC], distance, and time of continuous walking). Thirty-one patients participated in the development research. The levels of spinal cord injury were cervical (C5–C8), upper thoracic (T3–T6), lower thoracic (T7–T12), and lumbar (L1) in 10, 5, 15, and 1 of the patients, respectively. The numbers of patients with AIS scores of A, B, C, and D were 20, 7, 4, and 0, respectively. The total number of WPAL trials was 1,785, of which 1,009 were used the latest version of the WPAL. Twenty of the patients achieved an FAC score of 4 after an average of 9 (median 8, range 2–22) WPAL trials. The continuous walking distance and time improved with the WPAL were compared to the orthosis. We confirmed that the WPAL improves walking independence in people with a wide range of spinal cord injuries, such as cervical spinal cord injuries. Further refinement of the WPAL will enable its long-term use at home.
Collapse
Affiliation(s)
- Soichiro Koyama
- Faculty of Rehabilitation, School of Health Sciences, Fujita Health University, Toyoake, Japan
| | - Shigeo Tanabe
- Faculty of Rehabilitation, School of Health Sciences, Fujita Health University, Toyoake, Japan
| | - Takeshi Gotoh
- Department of Rehabilitation, Fujita Health University Hospital, Toyoake, Japan
| | - Yuta Taguchi
- Department of Rehabilitation, Fujita Health University Hospital, Toyoake, Japan
| | - Masaki Katoh
- Department of Rehabilitation, Fujita Health University Hospital, Toyoake, Japan
| | - Eiichi Saitoh
- Department of Rehabilitation Medicine I, School of Medicine, Fujita Health University, Toyoake, Japan
| | - Yohei Otaka
- Department of Rehabilitation Medicine I, School of Medicine, Fujita Health University, Toyoake, Japan
| | - Satoshi Hirano
- Department of Rehabilitation Medicine I, School of Medicine, Fujita Health University, Toyoake, Japan
- *Correspondence: Satoshi Hirano
| |
Collapse
|
16
|
Gutierrez F, Razghandi K. MotorSkins-a bio-inspired design approach towards an interactive soft-robotic exosuit. BIOINSPIRATION & BIOMIMETICS 2021; 16:066013. [PMID: 34530414 DOI: 10.1088/1748-3190/ac2785] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 04/21/2021] [Accepted: 09/16/2021] [Indexed: 06/13/2023]
Abstract
The work presents a bio-inspired design approach to a soft-robotic solution for assisting the knee-bending in users with reduced mobility in lower limbs. Exosuits and fluid-driven actuators are fabric-based devices that are gaining increasing relevance as alternatives assistive technologies that can provide simpler, more flexible solutions in comparison with the rigid exoskeletons. These devices, however, commonly require an external energy supply or a pressurized-fluid reservoir, which considerably constrain the autonomy of such solutions. In this work, we introduce an event-based energy cycle (EBEC) design concept, that can harvest, store, and release the required energy for assisting the knee-bending, in a synchronised interaction with the user and the environment, thus eliminating any need for external energy or control input. Ice-plant hydro-actuation system served as the source of inspiration to address the specific requirements of such interactive exosuit through a fluid-driven material system. Based on the EBEC design concepts and the abstracted bio-inspired principles, a series of (material and process driven) design experimentations helped to address the challenges of realising various functionalities of the harvest, storage, actuation and control instances within a closed hydraulic circuit. Sealing and defining various areas of water-tight seam made out of thermoplastic elastomers provided the base material system to program various chambers, channels, flow-check valves etc of such EBEC system. The resulting fluid-driven EBEC-skin served as a proof of concept for such active exosuit, that brings these functionalities into an integrated 'sense-acting' material system, realising an auto-synchronised energy and information cycles. The proposed design concept can serve as a model for development of similar fluid-driven EBEC soft-machines for further applications. On the more general scheme, the work presents an interdisciplinary design-science approach to bio-inspiration and showcases how biological material solutions can be looked at from a design/designer perspective to bridge the bottom-up and top-down approach to bio-inspiration.
Collapse
Affiliation(s)
- Facundo Gutierrez
- MotorSkins, Motionlab, Bouchéstraße 12, Halle20, Berlin, Berlin 12435, Germany
| | - Khashayar Razghandi
- Max Planck Institute of Colloids and Interfaces, Biomaterials Department, Potsdam, Germany
- Matters of Activity, Image Space Material, Cluster of Excellence Humboldt-Universität zu Berlin, Germany
| |
Collapse
|
17
|
Abstract
Owing to COVID-19, the world has advanced faster in the era of the Fourth Industrial Revolution, along with the 3D printing technology that has achieved innovation in personalized manufacturing. Three-dimensional printing technology has been utilized across various fields such as environmental fields, medical systems, and military materials. Recently, the 3D food printer global market has shown a high annual growth rate and is a huge industry of approximately one billion dollars. Three-dimensional food printing technology can be applied to various food ranges based on the advantages of designing existing food to suit one’s taste and purpose. Currently, many countries worldwide produce various 3D food printers, developing special foods such as combat food, space food, restaurants, floating food, and elderly food. Many people are unaware of the utilization of the 3D food printing technology industry as it is in its early stages. There are various cases using 3D food printing technology in various parts of the world. Three-dimensional food printing technology is expected to become a new trend in the new normal era after COVID-19. Compared to other 3D printing industries, food 3D printing technology has a relatively small overall 3D printing utilization and industry size because of problems such as insufficient institutionalization and limitation of standardized food materials for 3D food printing. In this review, the current industrial status of 3D food printing technology was investigated with suggestions for the improvement of the food 3D printing market in the new normal era.
Collapse
|
18
|
Treviño LR, Roberge P, Auer ME, Morales A, Torres-Reveron A. Predictors of Functional Outcome in a Cohort of Hispanic Patients Using Exoskeleton Rehabilitation for Cerebrovascular Accidents and Traumatic Brain Injury. Front Neurorobot 2021; 15:682156. [PMID: 34177511 PMCID: PMC8222710 DOI: 10.3389/fnbot.2021.682156] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/17/2021] [Accepted: 05/17/2021] [Indexed: 12/12/2022] Open
Abstract
Traumatic brain injury (TBI) and cerebrovascular accidents (CVA) are two of the leading causes of disability in the United States. Robotic exoskeletons (RE) have been approved for rehabilitation by the Federal Drug Administration (FDA) for use after a CVA, and recently received approval for use in patients with TBI. The aim of the study was to determine which factors predict the improvement in functional independence measure (FIM) score after using RE rehabilitation in a population of patients with CVA or TBI. We carried out a retrospective chart-review analysis of the use of the RE (Ekso® GT) in the rehabilitation of patients with TBI and CVA using data from a single, private rehabilitation hospital for patients admitted and discharged between 01/01/2017 and 04/30/2020. From the medical records, we collected presentation date, Glasgow Coma Scale score (GCS) on the date of injury, rehabilitation start date, age, diabetes status on presentation (Yes or No), injury category (TBI or CVA), and both admission and discharge FIM scores. Matching algorithms resulted in one TBI patient matched to three CVA patients resulting in a sample size of 36. The diabetic and non-diabetic populations showed significant differences between age and days from injury to the start of rehabilitation. A multivariate linear regression assessed predictors for discharge motor FIM and found admission motor FIM score and total RE steps to be statistically significant predictors. For each point scored higher on the admission motor FIM the discharge FIM was increased by 1.19 FIM points, and for each 1,000 steps taken in the RE, the discharge motor FIM increased by three points. The type of acquired brain injury (CVA or TBI) was not found to affect functional outcome. The presented results show that key clinic-biologic factors including diabetic status, together with start to rehabilitation play key roles in discharge FIM scores for patients using RE. Clinical Trial Registration: ClinicalTrials.gov, NCT04465019.
Collapse
Affiliation(s)
- Lisa R. Treviño
- DHR Health Institute for Research and Development, Edinburg, TX, United States
| | - Peter Roberge
- DHR Health Institute for Research and Development, Edinburg, TX, United States
| | - Michael E. Auer
- The DHR Health Rehabilitation Hospital, Edinburg, TX, United States
| | - Angela Morales
- The DHR Health Rehabilitation Hospital, Edinburg, TX, United States
| | | |
Collapse
|
19
|
Gorman PH, Forrest GF, Asselin PK, Scott W, Kornfeld S, Hong E, Spungen AM. The Effect of Exoskeletal-Assisted Walking on Spinal Cord Injury Bowel Function: Results from a Randomized Trial and Comparison to Other Physical Interventions. J Clin Med 2021; 10:jcm10050964. [PMID: 33801165 PMCID: PMC7957745 DOI: 10.3390/jcm10050964] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/30/2020] [Revised: 02/12/2021] [Accepted: 02/17/2021] [Indexed: 12/12/2022] Open
Abstract
Bowel function after spinal cord injury (SCI) is compromised because of a lack of voluntary control and reduction in bowel motility, often leading to incontinence and constipation not easily managed. Physical activity and upright posture may play a role in dealing with these issues. We performed a three-center, randomized, controlled, crossover clinical trial of exoskeletal-assisted walking (EAW) compared to usual activity (UA) in people with chronic SCI. As a secondary outcome measure, the effect of this intervention on bowel function was assessed using a 10-question bowel function survey, the Bristol Stool Form Scale (BSS) and the Spinal Cord Injury Quality of Life (SCI-QOL) Bowel Management Difficulties instrument. Fifty participants completed the study, with bowel data available for 49. The amount of time needed for the bowel program on average was reduced in 24% of the participants after EAW. A trend toward normalization of stool form was noted. There were no significant effects on patient-reported outcomes for bowel function for the SCI-QOL components, although the time since injury may have played a role. Subset analysis suggested that EAW produces a greater positive effect in men than women and may be more effective in motor-complete individuals with respect to stool consistency. EAW, along with other physical interventions previously investigated, may be able to play a previously underappreciated role in assisting with SCI-related bowel dysfunction.
Collapse
Affiliation(s)
- Peter H. Gorman
- Department of Neurology, University of Maryland School of Medicine, Baltimore, MD 21201, USA
- Division of Rehabilitation Medicine, University of Maryland Rehabilitation and Orthopaedic Institute, Baltimore, MD 21207, USA
- Correspondence: ; Tel.: +1-410-448-6265
| | - Gail F. Forrest
- Kessler Foundation, West Orange, NJ 07052, USA;
- Department of Physical Medicine and Rehabilitation, Rutgers New Jersey Medical School-Rutgers University, Newark, NJ 07103, USA
| | - Pierre K. Asselin
- Spinal Cord Damage Research Center, James J. Peters VA Medical Center, Bronx, NY 10468, USA; (P.K.A.); (S.K.); (E.H.); (A.M.S.)
- Department of Rehabilitation and Human Performance, Icahn School of Medicine at Mount Sinai, New York, NY 10029, USA
| | - William Scott
- VA Maryland Healthcare System, Baltimore, MD 21201, USA;
| | - Stephen Kornfeld
- Spinal Cord Damage Research Center, James J. Peters VA Medical Center, Bronx, NY 10468, USA; (P.K.A.); (S.K.); (E.H.); (A.M.S.)
- Department of Rehabilitation and Human Performance, Icahn School of Medicine at Mount Sinai, New York, NY 10029, USA
| | - Eunkyoung Hong
- Spinal Cord Damage Research Center, James J. Peters VA Medical Center, Bronx, NY 10468, USA; (P.K.A.); (S.K.); (E.H.); (A.M.S.)
- Department of Rehabilitation and Human Performance, Icahn School of Medicine at Mount Sinai, New York, NY 10029, USA
| | - Ann M. Spungen
- Spinal Cord Damage Research Center, James J. Peters VA Medical Center, Bronx, NY 10468, USA; (P.K.A.); (S.K.); (E.H.); (A.M.S.)
- Department of Rehabilitation and Human Performance, Icahn School of Medicine at Mount Sinai, New York, NY 10029, USA
| |
Collapse
|
20
|
Tan K, Koyama S, Sakurai H, Teranishi T, Kanada Y, Tanabe S. Wearable robotic exoskeleton for gait reconstruction in patients with spinal cord injury: A literature review. J Orthop Translat 2021; 28:55-64. [PMID: 33717982 PMCID: PMC7930505 DOI: 10.1016/j.jot.2021.01.001] [Citation(s) in RCA: 12] [Impact Index Per Article: 4.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 09/25/2020] [Revised: 12/25/2020] [Accepted: 01/07/2021] [Indexed: 12/13/2022] Open
Abstract
Objectives Wearable robotic exoskeletons (WREs) have been globally developed to achieve gait reconstruction in patients with spinal cord injury (SCI). The present study aimed to enable evidence-based decision-making in selecting the optimal WRE according to residual motor function and to provide a new perspective on further development of appropriate WREs. Methods The current review was conducted by searching PubMed, Web of Science, and Google Scholar for relevant studies published from April 2015 to February 2020. Selected studies were analysed with a focus on the participants’ neurological level of SCI, amount of training (number of training sessions and duration of the total training period), gait speed and endurance achieved, and subgroup exploration of the number of persons for assistance and the walking aid used among patients with cervical level injury. Results A total of 28 articles (nine using Ekso, three using Indego, ten using ReWalk, one using REX, five using Wearable Power-Assist Locomotor) involving 228 patients were included in the analysis. Across all WREs, T6 was the most frequently reported level of SCI. The amount of training showed a wide distribution (number of training sessions: 2–230 sessions [30–120 min per session]; duration of the total training period: 1–24 weeks [1–5 times per week]). The mean gait speed was 0.31 m/s (standard deviation [SD] 0.14), and the mean distance on the 6-min walking test as a measure of endurance was 108.9 m (SD 46.7). The subgroup exploration aimed at patients with cervical level injury indicated that 59.2% of patients were able to ambulate with no physical assistance and several patients used a walker as a walking aid. Conclusion The number of cervical level injury increased, as compared to the number previously indicated by a prior similar review. Training procedure was largely different among studies. Further improvement based on gait performance is required for use and dissemination in daily life. The translational potential of this article The present review reveals the current state of the clinical effectiveness of WREs for gait reconstruction in patients with SCI, contributing to evidence-based device application and further development.
Collapse
Affiliation(s)
- Koki Tan
- Graduate School of Health Sciences, Fujita Health University, Toyoake, Aichi, Japan
| | - Soichiro Koyama
- Faculty of Rehabilitation, School of Health Sciences, Fujita Health University, Toyoake, Aichi, Japan
| | - Hiroaki Sakurai
- Faculty of Rehabilitation, School of Health Sciences, Fujita Health University, Toyoake, Aichi, Japan
| | - Toshio Teranishi
- Faculty of Rehabilitation, School of Health Sciences, Fujita Health University, Toyoake, Aichi, Japan
| | - Yoshikiyo Kanada
- Faculty of Rehabilitation, School of Health Sciences, Fujita Health University, Toyoake, Aichi, Japan
| | - Shigeo Tanabe
- Faculty of Rehabilitation, School of Health Sciences, Fujita Health University, Toyoake, Aichi, Japan
- Corresponding author.
| |
Collapse
|
21
|
Rojek I, Mikołajewski D, Dostatni E, Macko M. AI-Optimized Technological Aspects of the Material Used in 3D Printing Processes for Selected Medical Applications. MATERIALS 2020; 13:ma13235437. [PMID: 33260398 PMCID: PMC7730732 DOI: 10.3390/ma13235437] [Citation(s) in RCA: 21] [Impact Index Per Article: 5.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 10/12/2020] [Revised: 11/25/2020] [Accepted: 11/27/2020] [Indexed: 12/18/2022]
Abstract
While the intensity, complexity, and specificity of robotic exercise may be supported by patient-tailored three-dimensional (3D)-printed solutions, their performance can still be compromised by non-optimal combinations of technological parameters and material features. The main focus of this paper was the computational optimization of the 3D-printing process in terms of features and material selection in order to achieve the maximum tensile force of a hand exoskeleton component, based on artificial neural network (ANN) optimization supported by genetic algorithms (GA). The creation and 3D-printing of the selected component was achieved using Cura 0.1.5 software and 3D-printed using fused filament fabrication (FFF) technology. To optimize the material and process parameters we compared ten selected parameters of the two distinct printing materials (polylactic acid (PLA), PLA+) using ANN supported by GA built and trained in the MATLAB environment. To determine the maximum tensile force of the exoskeleton, samples were tested using an INSTRON 5966 universal testing machine. While the balance between the technical requirements and user safety constraints requires further analysis, the PLA-based 3D-printing parameters have been optimized. Additive manufacturing may support the successful printing of usable/functional exoskeleton components. The network indicated which material should be selected: Namely PLA+. AI-based optimization may play a key role in increasing the performance and safety of the final product and supporting constraint satisfaction in patient-tailored solutions.
Collapse
Affiliation(s)
- Izabela Rojek
- Institute of Computer Science, Kazimierz Wielki University in Bydgoszcz, 85-064 Bydgoszcz, Poland;
- Correspondence: ; Tel.: +48-52-32-57-630
| | - Dariusz Mikołajewski
- Institute of Computer Science, Kazimierz Wielki University in Bydgoszcz, 85-064 Bydgoszcz, Poland;
| | - Ewa Dostatni
- Faculty of Mechanical Engineering, Poznan University of Technology, 60-965 Poznan, Poland;
| | - Marek Macko
- Department of Mechatronics, Kazimierz Wielki University in Bydgoszcz, 85-064 Bydgoszcz, Poland;
| |
Collapse
|
22
|
Kinnett-Hopkins D, Mummidisetty CK, Ehrlich-Jones L, Crown D, Bond RA, Applebaum MH, Jayaraman A, Furbish C, Forrest G, Field-Fote E, Heinemann AW. Users with spinal cord injury experience of robotic Locomotor exoskeletons: a qualitative study of the benefits, limitations, and recommendations. J Neuroeng Rehabil 2020; 17:124. [PMID: 32917287 PMCID: PMC7488437 DOI: 10.1186/s12984-020-00752-9] [Citation(s) in RCA: 13] [Impact Index Per Article: 3.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/28/2020] [Accepted: 08/31/2020] [Indexed: 01/13/2023] Open
Abstract
Background Persons with spinal cord injury (SCI) may experience both psychological and physiological benefits from robotic locomotor exoskeleton use, and knowledgeable users may have valuable perspectives to inform future development. The objective of this study is to gain insight into the experiences, perspectives, concerns, and suggestions on the use of robotic locomotor exoskeletons by civilians and veterans living with SCI. Methods Participants reported their demographic characteristics and the extent of robotic exoskeleton use in an online survey. Then, 28 experienced robotic locomotor exoskeleton users participated in focus groups held at three regional hospitals that specialize in rehabilitation for persons with SCI. We used a qualitative description approach analysis to analyze the data, and included thematic analysis. Results Participants expressed that robotic exoskeletons were useful in therapy settings but, in their current form, were not practical for activities of daily living due to device limitations. Participants detailed the psychological benefits of being eye-level with their non-disabled peers and family members, and some reported physiologic improvements in areas such as bowel and bladder function. Participants detailed barriers of increased fatigue, spasticity, and spasms and expressed dissatisfaction with the devices due to an inability to use them independently and safely. Participants provided suggestions to manufacturers for technology improvements. Conclusions The varied opinions and insights of robotic locomotor exoskeletons users with SCI add to our knowledge of device benefits and limitations.
Collapse
Affiliation(s)
| | | | | | | | | | | | | | | | - Gail Forrest
- Kessler Foundation, East Hanover, USA.,Rutgers New Jersey Medical School, Newark, USA
| | - Edelle Field-Fote
- Shepherd Center, Atlanta, USA.,Division of Physical Therapy, Emory University, Atlanta, USA
| | | |
Collapse
|
23
|
Gil-Agudo A, Del Ama-Espinosa AJ, Lozano-Berrio V, Fernández-López A, Megía García-Carpintero A, Benito-Penalva J, Pons JL. [Robot therapy with the H2 exoskeleton for gait rehabilitation in patients with incomplete spinal cord injry. A clinical experience]. Rehabilitacion (Madr) 2020; 54:87-95. [PMID: 32370833 DOI: 10.1016/j.rh.2019.10.004] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/24/2019] [Accepted: 10/22/2019] [Indexed: 11/17/2022]
Abstract
BACKGROUND AND OBJECTIVE Robotic exoskeletons have emerged as a promising tool in gait rehabilitation in patients with a spinal cord injury. The aim of this study was to assess the clinical applicability of a new robotic exoskeleton model (Exo H2) in the rehabilitation of people with incomplete spinal cord injury. MATERIAL AND METHODS Exo H2 exoskeleton training was performed for 15 sessions in patients with incomplete subacute spinal cord injury. We analysed the appearance of undesirable events and the patient's perception of pain, fatigue and comfort. In addition, a pilot test was carried out on the possible effectiveness of the device by analysing gait characteristics before and after treatment measured by the 10mWT, the 6mWT, the TUG, the WISCI-II, and the impact on the SCIM III scale. RESULTS Of a group of 8 patients recruited, we were able to analyse data from 4. No undesirable effects were reported. The VAS value was 2.28±1.55 for pain, 3.75±1.55 for fatigue and 4.17±1.68 for comfort. All values improved on the WISCI-I and the TUG and almost all in the 10MWT and in the 6MWT. CONCLUSIONS The performance of the Exo H2 exoskeleton was robust during a clinical protocol for gait rehabilitation. The treatment was safe, without undesirable effects and with good patient tolerance. These results might justify the performance of clinical trials with an adequate sample size.
Collapse
Affiliation(s)
- A Gil-Agudo
- Servicio de Rehabilitación, Hospital Nacional de Parapléjicos de Toledo, Toledo, España; Unidad de Neurorrehabilitación, Biomecánica y Función Sensitivo-Motora (HNP-SESCAM, Unidad asociada al CSIC).
| | - A J Del Ama-Espinosa
- Unidad de Biomecánica, Hospital Nacional de Parapléjicos de Toledo, Toledo, España; Área de Tecnología Electrónica, Universidad Rey Juan Carlos, Madrid, España
| | - V Lozano-Berrio
- Unidad de Biomecánica, Hospital Nacional de Parapléjicos de Toledo, Toledo, España
| | - A Fernández-López
- Servicio de Rehabilitación, Hospital Universitario Fundación Jiménez Díaz, Madrid, España
| | | | | | - J L Pons
- Grupo de Neuro-Rehabilitación, Instituto Cajal, CSIC, Madrid, España
| |
Collapse
|
24
|
Tamburella F, Tagliamonte NL, Pisotta I, Masciullo M, Arquilla M, van Asseldonk EHF, van der Kooij H, Wu AR, Dzeladini F, Ijspeert AJ, Molinari M. Neuromuscular Controller Embedded in a Powered Ankle Exoskeleton: Effects on Gait, Clinical Features and Subjective Perspective of Incomplete Spinal Cord Injured Subjects. IEEE Trans Neural Syst Rehabil Eng 2020; 28:1157-1167. [PMID: 32248116 DOI: 10.1109/tnsre.2020.2984790] [Citation(s) in RCA: 27] [Impact Index Per Article: 6.8] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/08/2022]
Abstract
Powered exoskeletons are among the emerging technologies claiming to assist functional ambulation. The potential to adapt robotic assistance based on specific motor abilities of incomplete spinal cord injury (iSCI) subjects, is crucial to optimize Human-Robot Interaction (HRI). Achilles, an autonomous wearable robot able to assist ankle during walking, was developed for iSCI subjects and utilizes a NeuroMuscular Controller (NMC). NMC can be used to adapt robotic assistance based on specific residual functional abilities of subjects. The main aim of this pilot study was to analyze the effects of the NMC-controlled Achilles, used as an assistive device, on chronic iSCI participants' performance, by assessing gait speed during 10-session training of robot-aided walking. Secondary aims were to assess training impact on participants' motion, clinical and functional features and to evaluate subjective perspective in terms of attitude towards technology, workload, usability and satisfaction. Results showed that 5 training sessions were necessary to significantly improve robot-aided gait speed on short paths and consequently to optimize HRI. Moreover, the training allowed participants who initially were not able to walk for 6 minutes, to improve gait endurance during Achilles-aided walking and to reduce perceived fatigue. Improvements were obtained also in gait speed during free walking, thus suggesting a potential rehabilitative impact, even if Achilles-aided walking was not faster than free walking. Participants' subjective evaluations indicated a positive experience.
Collapse
|
25
|
Maher JL, Baunsgaard CB, van Gerven J, Palermo AE, Biering-Sorensen F, Mendez A, Irwin RW, Nash MS. Differences in Acute Metabolic Responses to Bionic and Nonbionic Ambulation in Spinal Cord Injured Humans and Controls. Arch Phys Med Rehabil 2019; 101:121-129. [PMID: 31465760 DOI: 10.1016/j.apmr.2019.07.014] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/18/2019] [Accepted: 07/22/2019] [Indexed: 01/06/2023]
Abstract
OBJECTIVES To (1) compare energy expenditure during seated rest, standing, and prolonged bionic ambulation or bipedal ambulation in participants with spinal cord injury (SCI) and noninjured controls, respectively, and (2) test effects on postbionic ambulation glycemia in SCI. DESIGN Two independent group comparison of SCI and controls. SETTING Academic Medical Center. PARTICIPANTS Ten participants with chronic SCI (C7-T1, American Spinal Injury Association Impairment Scale A-C) and 10 controls (N=20). INTERVENTIONS A commercial bionic exoskeleton. MAIN OUTCOME MEASURES Absolute and relative (to peak) oxygen consumption, perceived exertion, carbohydrate/fat oxidation, energy expenditure, and postbionic ambulation plasma glucose/insulin. RESULTS Average work intensity accompanying 45 minutes of outdoor bionic ambulation was <40% peak oxygen consumption, with negligible drift after reaching steady state. Rating of perceived exertion (RPE) did not differ between groups and reflected low exertion. Absolute energy costs for bionic ambulation and nonbionic ambulation were not different between groups despite a 565% higher ambulation velocity in controls and 3.3× higher kilocalorie per meter in SCI. Fuel partitioning was similar between groups and the same within groups for carbohydrate and fat oxidation. Nonsignificant (9%) lowering of the area under a glucose tolerance curve following bionic ambulation required 20% less insulin than at rest. CONCLUSION Work intensity during prolonged bionic ambulation for this bionic exoskeleton is below a threshold for cardiorespiratory conditioning but above seated rest and passive standing. Bionic ambulation metabolism is consistent with low RPE and unchanged fuel partitioning from seated rest. Bionic ambulation did not promote beneficial effects on glycemia in well-conditioned, euglycemic participants. These findings may differ in less fit individuals with SCI or those with impaired glucose tolerance. Observed trends favoring this benefit suggest they are worthy of testing.
Collapse
Affiliation(s)
- Jennifer L Maher
- Miami Project to Cure Paralysis, University of Miami, Miller School of Medicine, Miami, Florida.
| | | | - Jan van Gerven
- Radboud University, Nijmegen Medical Center, Nijmegen, the Netherlands
| | - Anne E Palermo
- Miami Project to Cure Paralysis, University of Miami, Miller School of Medicine, Miami, Florida
| | | | - Armando Mendez
- Division of Endocrinology, Diabetes and Metabolism, Diabetes Research Institute, University of Miami, Miller School of Medicine, Miami, Florida
| | - Robert W Irwin
- Department of Physical Medicine and Rehabilitation, University of Miami, Miller School of Medicine, Miami, Florida
| | - Mark S Nash
- Miami Project to Cure Paralysis, University of Miami, Miller School of Medicine, Miami, Florida; Department of Neurological Surgery and Physical Medicine & Rehabilitation, University of Miami, Miller School of Medicine, Miami, Florida
| |
Collapse
|
26
|
Soliman AF, Sendur P, Ugurlu B. 3-D Dynamic Walking Trajectory Generation for a Bipedal Exoskeleton with Underactuated Legs: A Proof of Concept. IEEE Int Conf Rehabil Robot 2019; 2019:599-604. [PMID: 31374696 DOI: 10.1109/icorr.2019.8779438] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/09/2022]
Abstract
This paper presents a framework to address three dimensional (3-D) dynamic walking for a bipedal exoskeleton with underactuated legs. To achieve this goal, the framework is constructed via a trajectory generator and an optimized inverse kinematics algorithm that can cope with underactuation. In order to feasibly attain task velocities with underactuated legs, the inverse kinematics algorithm makes use of a task prioritization method via the exploitation of null space. In doing so, the tasks with lower priority, e.g., swing foot orientation, are attained as much as possible without disrupting the higher priority tasks, such as CoM trajectory. Meanwhile, the trajectory generator utilizes the ZMP concept analytically and ensures the acceleration continuity throughout the whole walking period, regardless of the contact and phase changes. The proposed method is verified via a lumped human-bipedal exoskeleton model that is developed and simulated in MSC.ADAMS simulation environment. As a result, we obtained feasible and dynamically balanced 3-D walking motion, in which no oblique foot landing or exaggerated torso orientation variations were observed, despite the underactuated nature of the robot legs.
Collapse
|
27
|
Yildirim MC, Kansizoglu AT, Emre S, Derman M, Coruk S, Soliman AF, Sendur P, Ugurlu B. Co-Ex: A Torque-Controllable Lower Body Exoskeleton for Dependable Human-Robot Co-existence. IEEE Int Conf Rehabil Robot 2019; 2019:605-610. [PMID: 31374697 DOI: 10.1109/icorr.2019.8779407] [Citation(s) in RCA: 6] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/09/2022]
Abstract
In this paper, we present our research study concerning the design and development of an exoskeleton that aims to provide 3D walking support with minimum number of actuators. Following a prior simulation study, the joint configuration was primarily determined. In order for the exoskeleton to possess advanced characteristics, the following design criteria were investigated: i) all the actuators (hip/knee/ankle) were deployed around the waist area to decrease leg weight and improve wearability, ii) custom-built series elastic actuators were used to power system for high fidelity torque-controllability, iii) 3D walking support is potentially enabled with reduced power requirements. As a result, we built the first actual prototype to experimentally verify the aforementioned design specifications. Furthermore, the preliminary torque control experiments indicated the viability of torque control.
Collapse
|
28
|
Exoskeleton for Gait Rehabilitation: Effects of Assistance, Mechanical Structure, and Walking Aids on Muscle Activations. APPLIED SCIENCES-BASEL 2019. [DOI: 10.3390/app9142868] [Citation(s) in RCA: 14] [Impact Index Per Article: 2.8] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 12/13/2022]
Abstract
Several exoskeletons have been developed and increasingly used in clinical settings for training and assisting locomotion. These devices allow people with severe motor deficits to regain mobility and sustain intense and repetitive gait training. However, three factors might affect normal muscle activations during walking: the assistive forces that are provided during walking, the crutches or walker that are always used in combination with the device, and the mechanical structure of the device itself. To investigate these effects, we evaluated eight healthy volunteers walking with the Ekso, which is a battery-powered, wearable exoskeleton. They walked supported by either crutches or a walker under five different assistance modalities: bilateral maximum assistance, no assistance, bilateral adaptive assistance, and unilateral adaptive assistance on each leg. Participants also walked overground without the exoskeleton. Surface electromyography was recorded bilaterally, and the statistical parametric mapping approach and muscle synergies analysis were used to investigate differences in muscular activity across different walking conditions. The lower limb muscle activations while walking with the Ekso were not influenced by the use of crutches or walker aids. Compared to normal walking without robotic assistance, the Ekso reduced the amplitude of activation for the distal lower limb muscles while changing the timing for the others. This depended mainly on the structure of the device, and not on the type or level of assistance. In fact, the presence of assistance did not change the timing of the muscle activations, but instead mainly had the effect of increasing the level of activation of the proximal lower limb muscles. Surprisingly, we found no significant changes in the adaptive control with respect to a maximal fixed assistance that did not account for subjects’ performance. These are important effects to take into careful considerations in clinics where these devices are used for gait rehabilitation in people with neurological diseases.
Collapse
|
29
|
Exoskeletons for Personal Use After Spinal Cord Injury. Arch Phys Med Rehabil 2019; 102:331-337. [PMID: 31228407 DOI: 10.1016/j.apmr.2019.05.028] [Citation(s) in RCA: 14] [Impact Index Per Article: 2.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/06/2019] [Revised: 04/11/2019] [Accepted: 05/28/2019] [Indexed: 02/07/2023]
Abstract
Before the development of robotic exoskeletons, mobility options beyond a wheelchair were very limited for most people lacking leg movement due to spinal cord injury (SCI). Over the years, robotic exoskeletons have become more widely available and now have the potential to be successfully used for personal use at home and in the community. However, it is important that users set realistic expectations. The features and capabilities of each robotic exoskeleton differ, and how exoskeletons are used may vary greatly between individuals. Robotic exoskeletons can allow individuals with SCI with varying levels of injury to safely and functionally walk for personal mobility or exercise. The following special communication will discuss important considerations surrounding exoskeleton use including feasibility, safety, cost, speed, and potential health benefits of using an exoskeleton for everyday life for people with SCI.
Collapse
|
30
|
Ugurlu B, Acer M, Barkana DE, Gocek I, Kucukyilmaz A, Arslan YZ, Basturk H, Samur E, Ugur E, Unal R, Bebek O. A Soft+Rigid Hybrid Exoskeleton Concept in Scissors-Pendulum Mode: A Suit for Human State Sensing and an Exoskeleton for Assistance. IEEE Int Conf Rehabil Robot 2019; 2019:518-523. [PMID: 31374682 DOI: 10.1109/icorr.2019.8779394] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 06/10/2023]
Abstract
In this paper, we present a novel concept that can enable the human aware control of exoskeletons through the integration of a soft suit and a robotic exoskeleton. Unlike the state-of-the-art exoskeleton controllers which mostly rely on lumped human-robot models, the proposed concept makes use of the independent state measurements concerning the human user and the robot. The ability to observe the human state independently is the key factor in this approach. In order to realize such a system from the hardware point of view, we propose a system integration frame that combines a soft suit for human state measurement and a rigid exoskeleton for human assistance. We identify the technological requirements that are necessary for the realization of such a system with a particular emphasis on soft suit integration. We also propose a template model, named scissor pendulum, that may encapsulate the dominant dynamics of the human-robot combined model to synthesize a controller for human state regulation. A series of simulation experiments were conducted to check the controller performance. As a result, satisfactory human state regulation was attained, adequately confirming that the proposed system could potentially improve exoskeleton-aided applications.
Collapse
|