1
|
Moses AS, Korzun T, Mamnoon B, Baldwin MK, Myatt L, Taratula O, Taratula OR. Nanomedicines for Improved Management of Ectopic Pregnancy: A Narrative Review. SMALL (WEINHEIM AN DER BERGSTRASSE, GERMANY) 2023:e2301873. [PMID: 37471169 PMCID: PMC10837845 DOI: 10.1002/smll.202301873] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 03/03/2023] [Revised: 07/04/2023] [Indexed: 07/22/2023]
Abstract
Ectopic pregnancy (EP) - the implantation of an embryo outside of the endometrial cavity, often in the fallopian tube - is a significant contributor to maternal morbidity and leading cause of maternal death due to hemorrhage in first trimester. Current diagnostic modalities including human chorionic gonadotropin (hCG) quantification and ultrasonography are effective, but may still misdiagnose EP at initial examination in many cases. Depending on the patient's hemodynamic stability and gestational duration of the pregnancy, as assessed by history, hCG measurement and ultrasonography, management strategies may include expectant management, chemotherapeutic treatment using methotrexate (MTX), or surgical intervention. While these strategies are largely successful, expectant management may result in tubal rupture if the pregnancy does not resolve spontaneously; MTX administration is not always successful and may induce significant side effects; and surgical intervention may result in loss of the already-damaged fallopian tube, further hampering the patient's subsequent attempts to conceive. Nanomaterial-based technologies offer the potential to enhance delivery of diagnostic imaging contrast and therapeutic agents to more effectively and safely manage EP. The purpose of this narrative review is to summarize the current state of nanomedicine technology dedicated to its potential to improve both the diagnosis and treatment of EP.
Collapse
Affiliation(s)
- Abraham S Moses
- Department of Pharmaceutical Sciences, College of Pharmacy, Oregon State University, 2730 S Moody Avenue, Portland, Oregon, 97201, USA
| | - Tetiana Korzun
- Department of Pharmaceutical Sciences, College of Pharmacy, Oregon State University, 2730 S Moody Avenue, Portland, Oregon, 97201, USA
| | - Babak Mamnoon
- Department of Pharmaceutical Sciences, College of Pharmacy, Oregon State University, 2730 S Moody Avenue, Portland, Oregon, 97201, USA
| | - Maureen K Baldwin
- Department of Obstetrics and Gynecology, School of Medicine, Oregon Health & Science University, 3181 SW Sam Jackson Park Road, Portland, OR, 97239, USA
| | - Leslie Myatt
- Department of Obstetrics and Gynecology, School of Medicine, Oregon Health & Science University, 3181 SW Sam Jackson Park Road, Portland, OR, 97239, USA
| | - Oleh Taratula
- Department of Pharmaceutical Sciences, College of Pharmacy, Oregon State University, 2730 S Moody Avenue, Portland, Oregon, 97201, USA
| | - Olena R Taratula
- Department of Pharmaceutical Sciences, College of Pharmacy, Oregon State University, 2730 S Moody Avenue, Portland, Oregon, 97201, USA
| |
Collapse
|
2
|
Maryam S, Nogueira MS, Gautam R, Krishnamoorthy S, Venkata Sekar SK, Kho KW, Lu H, Ni Riordain R, Feeley L, Sheahan P, Burke R, Andersson-Engels S. Label-Free Optical Spectroscopy for Early Detection of Oral Cancer. Diagnostics (Basel) 2022; 12:diagnostics12122896. [PMID: 36552903 PMCID: PMC9776497 DOI: 10.3390/diagnostics12122896] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/24/2022] [Revised: 11/16/2022] [Accepted: 11/18/2022] [Indexed: 11/23/2022] Open
Abstract
Oral cancer is the 16th most common cancer worldwide. It commonly arises from painless white or red plaques within the oral cavity. Clinical outcome is highly related to the stage when diagnosed. However, early diagnosis is complex owing to the impracticality of biopsying every potentially premalignant intraoral lesion. Therefore, there is a need to develop a non-invasive cost-effective diagnostic technique to differentiate non-malignant and early-stage malignant lesions. Optical spectroscopy may provide an appropriate solution to facilitate early detection of these lesions. It has many advantages over traditional approaches including cost, speed, objectivity, sensitivity, painlessness, and ease-of use in clinical setting for real-time diagnosis. This review consists of a comprehensive overview of optical spectroscopy for oral cancer diagnosis, epidemiology, and recent improvements in this field for diagnostic purposes. It summarizes major developments in label-free optical spectroscopy, including Raman, fluorescence, and diffuse reflectance spectroscopy during recent years. Among the wide range of optical techniques available, we chose these three for this review because they have the ability to provide biochemical information and show great potential for real-time deep-tissue point-based in vivo analysis. This review also highlights the importance of saliva-based potential biomarkers for non-invasive early-stage diagnosis. It concludes with the discussion on the scope of development and future demands from a clinical point of view.
Collapse
Affiliation(s)
- Siddra Maryam
- Tyndall National Institute, University College Cork, T12 R229 Cork, Ireland
- Correspondence:
| | | | - Rekha Gautam
- Tyndall National Institute, University College Cork, T12 R229 Cork, Ireland
| | | | | | - Kiang Wei Kho
- Tyndall National Institute, University College Cork, T12 R229 Cork, Ireland
| | - Huihui Lu
- Tyndall National Institute, University College Cork, T12 R229 Cork, Ireland
| | - Richeal Ni Riordain
- ENTO Research Institute, University College Cork, T12 R229 Cork, Ireland
- Cork University Dental School and Hospital, Wilton, T12 E8YV Cork, Ireland
| | - Linda Feeley
- ENTO Research Institute, University College Cork, T12 R229 Cork, Ireland
- Cork University Hospital, T12 DC4A Cork, Ireland
| | - Patrick Sheahan
- ENTO Research Institute, University College Cork, T12 R229 Cork, Ireland
- South Infirmary Victoria University Hospital, T12 X23H Cork, Ireland
| | - Ray Burke
- Tyndall National Institute, University College Cork, T12 R229 Cork, Ireland
| | | |
Collapse
|
3
|
O'Brien CM, Bishop KW, Zhang H, Xu X, Shmuylovich L, Conley E, Nwosu K, Duncan K, Mondal SB, Sudlow G, Achilefu S. Quantitative tumor depth determination using dual wavelength excitation fluorescence. BIOMEDICAL OPTICS EXPRESS 2022; 13:5628-5642. [PMID: 36733737 PMCID: PMC9872884 DOI: 10.1364/boe.468059] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 06/16/2022] [Revised: 08/10/2022] [Accepted: 08/16/2022] [Indexed: 06/07/2023]
Abstract
Quantifying solid tumor margins with fluorescence-guided surgery approaches is a challenge, particularly when using near infrared (NIR) wavelengths due to increased penetration depths. An NIR dual wavelength excitation fluorescence (DWEF) approach was developed that capitalizes on the wavelength-dependent attenuation of light in tissue to determine fluorophore depth. A portable dual wavelength excitation fluorescence imaging system was built and tested in parallel with an NIR tumor-targeting fluorophore in tissue mimicking phantoms, chicken tissue, and in vivo mouse models of breast cancer. The system showed high accuracy in all experiments. The low cost and simplicity of this approach make it ideal for clinical use.
Collapse
Affiliation(s)
- Christine M O'Brien
- Department of Radiology, Washington University School of Medicine, 4515 McKinley Ave., St. Louis, MO, 63110, USA
- Department of Biomedical Engineering, Washington University in St. Louis, 1 Brookings Drive St. Louis, MO 63130, USA
- These authors contributed equally to this work
| | - Kevin W Bishop
- Department of Radiology, Washington University School of Medicine, 4515 McKinley Ave., St. Louis, MO, 63110, USA
| | - Haini Zhang
- Department of Radiology, Washington University School of Medicine, 4515 McKinley Ave., St. Louis, MO, 63110, USA
- Department of Biomedical Engineering, Washington University in St. Louis, 1 Brookings Drive St. Louis, MO 63130, USA
| | - Xiao Xu
- Department of Radiology, Washington University School of Medicine, 4515 McKinley Ave., St. Louis, MO, 63110, USA
| | - Leo Shmuylovich
- Department of Radiology, Washington University School of Medicine, 4515 McKinley Ave., St. Louis, MO, 63110, USA
- Division of Dermatology, Department of Medicine, Washington University School of Medicine, 4960 Children's Place, St. Louis, MO 63110, USA
| | - Elizabeth Conley
- Department of Radiology, Washington University School of Medicine, 4515 McKinley Ave., St. Louis, MO, 63110, USA
| | - Karen Nwosu
- Department of Radiology, Washington University School of Medicine, 4515 McKinley Ave., St. Louis, MO, 63110, USA
| | - Kathleen Duncan
- Department of Radiology, Washington University School of Medicine, 4515 McKinley Ave., St. Louis, MO, 63110, USA
| | - Suman B Mondal
- Department of Radiology, Washington University School of Medicine, 4515 McKinley Ave., St. Louis, MO, 63110, USA
| | - Gail Sudlow
- Department of Radiology, Washington University School of Medicine, 4515 McKinley Ave., St. Louis, MO, 63110, USA
| | - Samuel Achilefu
- Department of Radiology, Washington University School of Medicine, 4515 McKinley Ave., St. Louis, MO, 63110, USA
- Department of Biomedical Engineering, Washington University in St. Louis, 1 Brookings Drive St. Louis, MO 63130, USA
- Department of Medicine, Washington University School of Medicine, 4960 Children's Place, St. Louis, MO 63110, USA
- Department of Biochemistry and Molecular Biophysics, Washington University School of Medicine, 660 S. Euclid Ave., St. Louis, MO 63110, USA
- These authors contributed equally to this work
| |
Collapse
|
4
|
Kirillin M, Khilov A, Kurakina D, Orlova A, Perekatova V, Shishkova V, Malygina A, Mironycheva A, Shlivko I, Gamayunov S, Turchin I, Sergeeva E. Dual-Wavelength Fluorescence Monitoring of Photodynamic Therapy: From Analytical Models to Clinical Studies. Cancers (Basel) 2021; 13:cancers13225807. [PMID: 34830963 PMCID: PMC8616416 DOI: 10.3390/cancers13225807] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/30/2021] [Revised: 11/03/2021] [Accepted: 11/09/2021] [Indexed: 11/16/2022] Open
Abstract
Simple Summary Fluorescence imaging is an efficient tool in monitoring photodynamic therapy procedures allowing us to track accumulation and photobleaching of a photosensitizer (PS). Chlorin-based PSs feature high absorption in the red and blue bands of visible spectrum. Due to spectral dispersion of light penetration depth in biotissues, fluorescence signals registered upon excitation by red or blue light are formed in different measurement volumes. We present analytical and numerical models of dual-wavelength fluorescence imaging for evaluation of PS localization depth in the cases of topical administration and intravenous injection. The results of analytical and numerical simulations are in good agreement with the phantom experiments, and are translated to the in vivo imaging, which allows to interpret experimental observations in animal trials, human volunteers, and clinical studies. The proposed approach allows us to noninvasively estimate typical accumulation depths of PS localization which are consistent with the morphologically expected values. Abstract Fluorescence imaging modalities are currently a routine tool for the assessment of marker distribution within biological tissues, including monitoring of fluorescent photosensitizers (PSs) in photodynamic therapy (PDT). Conventional fluorescence imaging techniques provide en-face two-dimensional images, while depth-resolved techniques require complicated tomographic modalities. In this paper, we report on a cost-effective approach for the estimation of fluorophore localization depth based on dual-wavelength probing. Owing to significant difference in optical properties of superficial biotissues for red and blue ranges of optical spectra, simultaneous detection of fluorescence excited at different wavelengths provides complementary information from different measurement volumes. Here, we report analytical and numerical models of the dual-wavelength fluorescence imaging of PS-containing biotissues considering topical and intravenous PS administration, and demonstrate the feasibility of this approach for evaluation of the PS localization depth based on the fluorescence signal ratio. The results of analytical and numerical simulations, as well as phantom experiments, were translated to the in vivo imaging to interpret experimental observations in animal experiments, human volunteers, and clinical studies. The proposed approach allowed us to estimate typical accumulation depths of PS localization which are consistent with the morphologically expected values for both topical PS administration and intravenous injection.
Collapse
Affiliation(s)
- Mikhail Kirillin
- Institute of Applied Physics RAS, 46 Ulyanov St., 603950 Nizhny Novgorod, Russia
| | - Aleksandr Khilov
- Institute of Applied Physics RAS, 46 Ulyanov St., 603950 Nizhny Novgorod, Russia
| | - Daria Kurakina
- Institute of Applied Physics RAS, 46 Ulyanov St., 603950 Nizhny Novgorod, Russia
| | - Anna Orlova
- Institute of Applied Physics RAS, 46 Ulyanov St., 603950 Nizhny Novgorod, Russia
| | - Valeriya Perekatova
- Institute of Applied Physics RAS, 46 Ulyanov St., 603950 Nizhny Novgorod, Russia
| | - Veronika Shishkova
- Institute of Applied Physics RAS, 46 Ulyanov St., 603950 Nizhny Novgorod, Russia
- Institute of Information Technology, Mathematics and Mechanics, Lobachevsky State University of Nizhny Novgorod, 23 Gagarin Avenue, 603022 Nizhny Novgorod, Russia
| | - Alfia Malygina
- Center for Skin Tumor Diagnostics and Treatment, Privolzhsky Research Medical University, 10/1 Minin and Pozharsky Sq., 603005 Nizhny Novgorod, Russia
| | - Anna Mironycheva
- Institute of Applied Physics RAS, 46 Ulyanov St., 603950 Nizhny Novgorod, Russia
- Center for Skin Tumor Diagnostics and Treatment, Privolzhsky Research Medical University, 10/1 Minin and Pozharsky Sq., 603005 Nizhny Novgorod, Russia
| | - Irena Shlivko
- Center for Skin Tumor Diagnostics and Treatment, Privolzhsky Research Medical University, 10/1 Minin and Pozharsky Sq., 603005 Nizhny Novgorod, Russia
| | - Sergey Gamayunov
- Institute of Applied Physics RAS, 46 Ulyanov St., 603950 Nizhny Novgorod, Russia
- Nizhny Novgorod Regional Oncological Hospital, Delovaya 11/1, 603126 Nizhny Novgorod, Russia
| | - Ilya Turchin
- Institute of Applied Physics RAS, 46 Ulyanov St., 603950 Nizhny Novgorod, Russia
| | - Ekaterina Sergeeva
- Institute of Applied Physics RAS, 46 Ulyanov St., 603950 Nizhny Novgorod, Russia
| |
Collapse
|
5
|
Komolibus K, Fisher C, Swartling J, Svanberg S, Svanberg K, Andersson-Engels S. Perspectives on interstitial photodynamic therapy for malignant tumors. JOURNAL OF BIOMEDICAL OPTICS 2021; 26:JBO-210111-PERR. [PMID: 34302323 PMCID: PMC8299827 DOI: 10.1117/1.jbo.26.7.070604] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 04/06/2021] [Accepted: 07/08/2021] [Indexed: 05/17/2023]
Abstract
SIGNIFICANCE Despite remarkable advances in the core modalities used in combating cancer, malignant diseases remain the second largest cause of death globally. Interstitial photodynamic therapy (IPDT) has emerged as an alternative approach for the treatment of solid tumors. AIM The aim of our study is to outline the advancements in IPDT in recent years and provide our vision for the inclusion of IPDT in standard-of-care (SoC) treatment guidelines of specific malignant diseases. APPROACH First, the SoC treatment for solid tumors is described, and the attractive properties of IPDT are presented. Second, the application of IPDT for selected types of tumors is discussed. Finally, future opportunities are considered. RESULTS Strong research efforts in academic, clinical, and industrial settings have led to significant improvements in the current implementation of IPDT, and these studies have demonstrated the unique advantages of this modality for the treatment of solid tumors. It is envisioned that further randomized prospective clinical trials and treatment optimization will enable a wide acceptance of IPDT in the clinical community and inclusion in SoC guidelines for well-defined clinical indications. CONCLUSIONS The minimally invasive nature of this treatment modality combined with the relatively mild side effects makes IPDT a compelling alternative option for treatment in a number of clinical applications. The adaptability of this technique provides many opportunities to both optimize and personalize the treatment.
Collapse
Affiliation(s)
- Katarzyna Komolibus
- Tyndall National Institute, Biophotonics@Tyndall, IPIC, Cork, Ireland
- Address all correspondence to Katarzyna Komolibus,
| | - Carl Fisher
- Tyndall National Institute, Biophotonics@Tyndall, IPIC, Cork, Ireland
| | | | - Sune Svanberg
- Lund University, Department of Physics, Lund, Sweden
- South China Normal University, South China Academy of Advanced Optoelectronics, Guangzhou, China
| | - Katarina Svanberg
- South China Normal University, South China Academy of Advanced Optoelectronics, Guangzhou, China
- Lund University Hospital, Department of Clinical Sciences, Lund, Sweden
| | - Stefan Andersson-Engels
- Tyndall National Institute, Biophotonics@Tyndall, IPIC, Cork, Ireland
- University College Cork, Department of Physics, Cork, Ireland
| |
Collapse
|
6
|
Smith JT, Aguénounon E, Gioux S, Intes X. Macroscopic fluorescence lifetime topography enhanced via spatial frequency domain imaging. OPTICS LETTERS 2020; 45:4232-4235. [PMID: 32735266 PMCID: PMC7935427 DOI: 10.1364/ol.397605] [Citation(s) in RCA: 15] [Impact Index Per Article: 3.8] [Reference Citation Analysis] [Abstract] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/15/2023]
Abstract
We report on a macroscopic fluorescence lifetime imaging (MFLI) topography computational framework based around machine learning with the main goal of retrieving the depth of fluorescent inclusions deeply seated in bio-tissues. This approach leverages the depth-resolved information inherent to time-resolved fluorescence data sets coupled with the retrieval of in situ optical properties as obtained via spatial frequency domain imaging (SFDI). Specifically, a Siamese network architecture is proposed with optical properties (OPs) and time-resolved fluorescence decays as input followed by simultaneous retrieval of lifetime maps and depth profiles. We validate our approach using comprehensive in silico data sets as well as with a phantom experiment. Overall, our results demonstrate that our approach can retrieve the depth of fluorescence inclusions, especially when coupled with optical properties estimation, with high accuracy. We expect the presented computational approach to find great utility in applications such as optical-guided surgery.
Collapse
Affiliation(s)
- Jason T. Smith
- Department of Biomedical Engineering, Rensselaer Polytechnic Institute, Troy, New York 12180, USA
| | - Enagnon Aguénounon
- University of Strasbourg, ICube Laboratory, 300 Boulevard Sebastien Brant, 67412 Illkirch, France
| | - Sylvain Gioux
- University of Strasbourg, ICube Laboratory, 300 Boulevard Sebastien Brant, 67412 Illkirch, France
| | - Xavier Intes
- Department of Biomedical Engineering, Rensselaer Polytechnic Institute, Troy, New York 12180, USA
- Corresponding author:
| |
Collapse
|
7
|
Etrych T, Janoušková O, Chytil P. Fluorescence Imaging as a Tool in Preclinical Evaluation of Polymer-Based Nano-DDS Systems Intended for Cancer Treatment. Pharmaceutics 2019; 11:E471. [PMID: 31547308 PMCID: PMC6781319 DOI: 10.3390/pharmaceutics11090471] [Citation(s) in RCA: 17] [Impact Index Per Article: 3.4] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/02/2019] [Revised: 08/29/2019] [Accepted: 09/04/2019] [Indexed: 01/04/2023] Open
Abstract
Targeted drug delivery using nano-sized carrier systems with targeting functions to malignant and inflammatory tissue and tailored controlled drug release inside targeted tissues or cells has been and is still intensively studied. A detailed understanding of the correlation between the pharmacokinetic properties and structure of the nano-sized carrier is crucial for the successful transition of targeted drug delivery nanomedicines into clinical practice. In preclinical research in particular, fluorescence imaging has become one of the most commonly used powerful imaging tools. Increasing numbers of suitable fluorescent dyes that are excitable in the visible to near-infrared (NIR) wavelengths of the spectrum and the non-invasive nature of the method have significantly expanded the applicability of fluorescence imaging. This chapter summarizes non-invasive fluorescence-based imaging methods and discusses their potential advantages and limitations in the field of drug delivery, especially in anticancer therapy. This chapter focuses on fluorescent imaging from the cellular level up to the highly sophisticated three-dimensional imaging modality at a systemic level. Moreover, we describe the possibility for simultaneous treatment and imaging using fluorescence theranostics and the combination of different imaging techniques, e.g., fluorescence imaging with computed tomography.
Collapse
Affiliation(s)
- Tomáš Etrych
- Institute of Macromolecular Chemistry, Czech Academy of Sciences, Heyrovského nám. 2, 162 06 Prague 6, Czech Republic.
| | - Olga Janoušková
- Institute of Macromolecular Chemistry, Czech Academy of Sciences, Heyrovského nám. 2, 162 06 Prague 6, Czech Republic
| | - Petr Chytil
- Institute of Macromolecular Chemistry, Czech Academy of Sciences, Heyrovského nám. 2, 162 06 Prague 6, Czech Republic
| |
Collapse
|
8
|
Roberts DW, Olson JD, Evans LT, Kolste KK, Kanick SC, Fan X, Bravo JJ, Wilson BC, Leblond F, Marois M, Paulsen KD. Red-light excitation of protoporphyrin IX fluorescence for subsurface tumor detection. J Neurosurg 2018; 128:1690-1697. [PMID: 28777025 PMCID: PMC5797501 DOI: 10.3171/2017.1.jns162061] [Citation(s) in RCA: 31] [Impact Index Per Article: 5.2] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/02/2023]
Abstract
OBJECTIVE The objective of this study was to detect 5-aminolevulinic acid (ALA)-induced tumor fluorescence from glioma below the surface of the surgical field by using red-light illumination. METHODS To overcome the shallow tissue penetration of blue light, which maximally excites the ALA-induced fluorophore protoporphyrin IX (PpIX) but is also strongly absorbed by hemoglobin and oxyhemoglobin, a system was developed to illuminate the surgical field with red light (620-640 nm) matching a secondary, smaller absorption peak of PpIX and detecting the fluorescence emission through a 650-nm longpass filter. This wide-field spectroscopic imaging system was used in conjunction with conventional blue-light fluorescence for comparison in 29 patients undergoing craniotomy for resection of high-grade glioma, low-grade glioma, meningioma, or metastasis. RESULTS Although, as expected, red-light excitation is less sensitive to PpIX in exposed tumor, it did reveal tumor at a depth up to 5 mm below the resection bed in 22 of 24 patients who also exhibited PpIX fluorescence under blue-light excitation during the course of surgery. CONCLUSIONS Red-light excitation of tumor-associated PpIX fluorescence below the surface of the surgical field can be achieved intraoperatively and enables detection of subsurface tumor that is not visualized under conventional blue-light excitation. Clinical trial registration no.: NCT02191488 (clinicaltrials.gov).
Collapse
Affiliation(s)
- David W. Roberts
- Section of Neurosurgery, Dartmouth-Hitchcock Medical Center, Lebanon
- Geisel School of Medicine, Dartmouth College, Hanover, New Hampshire
- Norris Cotton Cancer Center, Dartmouth-Hitchcock Medical Center, Lebanon
- Thayer School of Engineering, Dartmouth College, Hanover, New Hampshire
| | - Jonathan D. Olson
- Thayer School of Engineering, Dartmouth College, Hanover, New Hampshire
| | - Linton T. Evans
- Section of Neurosurgery, Dartmouth-Hitchcock Medical Center, Lebanon
| | - Kolbein K. Kolste
- Thayer School of Engineering, Dartmouth College, Hanover, New Hampshire
| | - Stephen C. Kanick
- Thayer School of Engineering, Dartmouth College, Hanover, New Hampshire
| | - Xiaoyao Fan
- Section of Neurosurgery, Dartmouth-Hitchcock Medical Center, Lebanon
- Thayer School of Engineering, Dartmouth College, Hanover, New Hampshire
| | - Jaime J. Bravo
- Thayer School of Engineering, Dartmouth College, Hanover, New Hampshire
| | - Brian C. Wilson
- Princess Margaret Cancer Centre/University Health Network and Department of Medical Biophysics, University of Toronto, Ontario
| | - Frederic Leblond
- Department of Engineering Physics, Polytechnique Montreal, Quebec
- Centre de Recherche du Centre Hospitalier de l’Université de Montréal, Quebec, Canada
| | - Mikael Marois
- Thayer School of Engineering, Dartmouth College, Hanover, New Hampshire
| | - Keith D. Paulsen
- Section of Neurosurgery, Dartmouth-Hitchcock Medical Center, Lebanon
- Norris Cotton Cancer Center, Dartmouth-Hitchcock Medical Center, Lebanon
- Thayer School of Engineering, Dartmouth College, Hanover, New Hampshire
| |
Collapse
|
9
|
Rehman AU, Anwer AG, Goldys EM. Programmable LED-based integrating sphere light source for wide-field fluorescence microscopy. Photodiagnosis Photodyn Ther 2017; 20:201-206. [PMID: 29042307 DOI: 10.1016/j.pdpdt.2017.10.002] [Citation(s) in RCA: 7] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/02/2017] [Revised: 09/13/2017] [Accepted: 10/07/2017] [Indexed: 11/30/2022]
Abstract
Wide-field fluorescence microscopy commonly uses a mercury lamp, which has limited spectral capabilities. We designed and built a programmable integrating sphere light (PISL) source which consists of nine LEDs, light-collecting optics, a commercially available integrating sphere and a baffle. The PISL source is tuneable in the range 365-490nm with a uniform spatial profile and a sufficient power at the objective to carry out spectral imaging. We retrofitted a standard fluorescence inverted microscope DM IRB (Leica) with a PISL source by mounting it together with a highly sensitive low- noise CMOS camera. The capabilities of the setup have been demonstrated by carrying out multispectral autofluorescence imaging of live BV2 cells.
Collapse
Affiliation(s)
- Aziz Ul Rehman
- ARC Centre of Excellence in Nanoscale Biophotonics, Macquarie University, Sydney, 2109, New South Wales, Australia; Department of Physics and Astronomy Macquarie University, Sydney, 2109, New South Wales, Australia; Biophotonics Laboratory, National Institute of Lasers and Optronics, Lehtrar Road, Islamabad 45650, Pakistan.
| | - Ayad G Anwer
- ARC Centre of Excellence in Nanoscale Biophotonics, Macquarie University, Sydney, 2109, New South Wales, Australia; Department of Physics and Astronomy Macquarie University, Sydney, 2109, New South Wales, Australia
| | - Ewa M Goldys
- ARC Centre of Excellence in Nanoscale Biophotonics, Macquarie University, Sydney, 2109, New South Wales, Australia; Department of Physics and Astronomy Macquarie University, Sydney, 2109, New South Wales, Australia
| |
Collapse
|
10
|
Wirth D, Kolste K, Kanick S, Roberts DW, Leblond F, Paulsen KD. Fluorescence depth estimation from wide-field optical imaging data for guiding brain tumor resection: a multi-inclusion phantom study. BIOMEDICAL OPTICS EXPRESS 2017; 8:3656-3670. [PMID: 28856042 PMCID: PMC5560832 DOI: 10.1364/boe.8.003656] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 04/14/2017] [Revised: 06/17/2017] [Accepted: 07/01/2017] [Indexed: 05/08/2023]
Abstract
Studies have shown that fluorescent agents demarcate tumor from surrounding brain tissue and offer intraoperative guidance during resection. However, visualization of fluorescence signal from tumor below the surgical surface or through the appearance of blood in the surgical field is challenging. We have previously described red light imaging techniques for estimating fluorescent depths in turbid media. In this study, we evaluate these methods over a broader range of fluorophore concentrations, and investigate the ability to resolve multiple fluorescent emissions in the same plane or at different depths along the axis of imaging. A tungsten halogen lamp is used as a broadband white light source for reflectance imaging. Fluorescence from Alexa Fluor 647 is excited with a 635 nm diode laser. Reflectance and fluorescence spectral data are gathered between 670 and 720 nm with the use of a liquid crystal tunable filter and recorded on a sCMOS camera. Results show that two fluorescent emissions can be resolved within 2 mm if they are in the same plane or within 3 mm if they are at different depths along the axis of imaging up to 6 mm below the surface.
Collapse
Affiliation(s)
- Dennis Wirth
- Department of Surgery, Dartmouth-Hitchcock Medical Center, 1 Medical Center Dr. Lebanon, NH 03766, USA
| | - Kolbein Kolste
- Thayer School of Engineering, Dartmouth College, 14 Engineering Dr. Hanover, NH 03755, USA
| | - Stephen Kanick
- Thayer School of Engineering, Dartmouth College, 14 Engineering Dr. Hanover, NH 03755, USA
| | - David W. Roberts
- Section of Neurosurgery, Dartmouth-Hitchcock Medical Center, 1 Medical Center Dr. Lebanon, NH 03766, USA
| | - Frédéric Leblond
- Polytechnique Montreal, Engineering Physics Department, Montreal, Québec H3C 3A7, Canada
| | - Keith D. Paulsen
- Thayer School of Engineering, Dartmouth College, 14 Engineering Dr. Hanover, NH 03755, USA
| |
Collapse
|
11
|
Miller JP, Habimana-Griffin L, Edwards TS, Achilefu S. Multimodal fluorescence molecular imaging for in vivo characterization of skin cancer using endogenous and exogenous fluorophores. JOURNAL OF BIOMEDICAL OPTICS 2017; 22:66007. [PMID: 28613348 PMCID: PMC5470328 DOI: 10.1117/1.jbo.22.6.066007] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 03/09/2017] [Accepted: 05/23/2017] [Indexed: 06/07/2023]
Abstract
Similarity of skin cancer with many benign skin pathologies requires reliable methods to detect and differentiate the different types of these lesions. Previous studies have explored the use of disparate optical techniques to identify and estimate the invasive nature of melanoma and basal cell carcinoma with varying outcomes. Here, we used a concerted approach that provides complementary information for rapid screening and characterization of tumors, focusing on squamous cell carcinoma (SCC) of the skin. Assessment of in vivo autofluorescence lifetime (FLT) imaging of endogenous fluorophores that are excitable at longer wavelengths (480 nm) than conventional NADH and FAD revealed a decrease in the short FLT component for SCC compared to normal skin, with mean values of 0.57 ± 0.026 ?? ns and 0.61 ± 0.021 ?? ns , respectively ( p = 0.004 ). Subsequent systemic administration of a near-infrared fluorescent molecular probe in SCC bearing mice, followed by the implementation of image processing methods on data acquired from two-dimensional and three-dimensional fluorescence molecular imaging, allowed us to estimate the tumor volume and depth, as well as quantify the fluorescent probe in the tumor. The result suggests the involvement of lipofuscin-like lipopigments and riboflavin in SCC metabolism and serves as a model for staging SCC.
Collapse
Affiliation(s)
- Jessica P. Miller
- Washington University School of Medicine, Mallinckrodt Institute of Radiology, Optical Radiology Laboratory, St. Louis, Missouri, United States
- Washington University in St. Louis, Biomedical Engineering, St. Louis, Missouri, United States
| | - LeMoyne Habimana-Griffin
- Washington University School of Medicine, Mallinckrodt Institute of Radiology, Optical Radiology Laboratory, St. Louis, Missouri, United States
- Washington University in St. Louis, Biomedical Engineering, St. Louis, Missouri, United States
| | - Tracy S. Edwards
- Washington University School of Medicine, Mallinckrodt Institute of Radiology, Optical Radiology Laboratory, St. Louis, Missouri, United States
| | - Samuel Achilefu
- Washington University School of Medicine, Mallinckrodt Institute of Radiology, Optical Radiology Laboratory, St. Louis, Missouri, United States
- Washington University in St. Louis, Biomedical Engineering, St. Louis, Missouri, United States
| |
Collapse
|
12
|
Miller JP, Maji D, Lam J, Tromberg BJ, Achilefu S. Noninvasive depth estimation using tissue optical properties and a dual-wavelength fluorescent molecular probe in vivo. BIOMEDICAL OPTICS EXPRESS 2017; 8:3095-3109. [PMID: 28663929 PMCID: PMC5480452 DOI: 10.1364/boe.8.003095] [Citation(s) in RCA: 10] [Impact Index Per Article: 1.4] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 02/27/2017] [Revised: 05/21/2017] [Accepted: 05/25/2017] [Indexed: 05/28/2023]
Abstract
Translation of fluorescence imaging using molecularly targeted imaging agents for real-time assessment of surgical margins in the operating room requires a fast and reliable method to predict tumor depth from planar optical imaging. Here, we developed a dual-wavelength fluorescent molecular probe with distinct visible and near-infrared excitation and emission spectra for depth estimation in mice and a method to predict the optical properties of the imaging medium such that the technique is applicable to a range of medium types. Imaging was conducted at two wavelengths in a simulated blood vessel and an in vivo tumor model. Although the depth estimation method was insensitive to changes in the molecular probe concentration, it was responsive to the optical parameters of the medium. Results of the intra-tumor fluorescent probe injection showed that the average measured tumor sub-surface depths were 1.31 ± 0.442 mm, 1.07 ± 0.187 mm, and 1.42 ± 0.182 mm, and the average estimated sub-surface depths were 0.97 ± 0.308 mm, 1.11 ± 0.428 mm, 1.21 ± 0.492 mm, respectively. Intravenous injection of the molecular probe allowed for selective tumor accumulation, with measured tumor sub-surface depths of 1.28 ± 0.168 mm, and 1.50 ± 0.394 mm, and the estimated depths were 1.46 ± 0.314 mm, and 1.60 ± 0.409 mm, respectively. Expansion of our technique by using material optical properties and mouse skin optical parameters to estimate the sub-surface depth of a tumor demonstrated an agreement between measured and estimated depth within 0.38 mm and 0.63 mm for intra-tumor and intravenous dye injections, respectively. Our results demonstrate the feasibility of dual-wavelength imaging for determining the depth of blood vessels and characterizing the sub-surface depth of tumors in vivo.
Collapse
Affiliation(s)
- Jessica P. Miller
- Optical Radiology Lab, Mallinckrodt Institute of Radiology, Washington University School of Medicine, 4515 McKinley Ave, St. Louis, Missouri 63110, USA
- Biomedical Engineering, Washington University in St. Louis, St. Louis, Missouri 63130, USA
- Co-contributing first authors contributed equally
| | - Dolonchampa Maji
- Optical Radiology Lab, Mallinckrodt Institute of Radiology, Washington University School of Medicine, 4515 McKinley Ave, St. Louis, Missouri 63110, USA
- Biomedical Engineering, Washington University in St. Louis, St. Louis, Missouri 63130, USA
- Co-contributing first authors contributed equally
| | - Jesse Lam
- Laser Microbeam and Medical Program, Beckman Laser Institute, University of California, Irvine, Irvine, California 92612, USA
| | - Bruce J. Tromberg
- Laser Microbeam and Medical Program, Beckman Laser Institute, University of California, Irvine, Irvine, California 92612, USA
| | - Samuel Achilefu
- Optical Radiology Lab, Mallinckrodt Institute of Radiology, Washington University School of Medicine, 4515 McKinley Ave, St. Louis, Missouri 63110, USA
- Biomedical Engineering, Washington University in St. Louis, St. Louis, Missouri 63130, USA
| |
Collapse
|
13
|
Fluorescence optical imaging in anticancer drug delivery. J Control Release 2016; 226:168-81. [PMID: 26892751 DOI: 10.1016/j.jconrel.2016.02.022] [Citation(s) in RCA: 84] [Impact Index Per Article: 10.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/24/2015] [Revised: 02/10/2016] [Accepted: 02/11/2016] [Indexed: 12/21/2022]
Abstract
In the past several decades, nanosized drug delivery systems with various targeting functions and controlled drug release capabilities inside targeted tissues or cells have been intensively studied. Understanding their pharmacokinetic properties is crucial for the successful transition of this research into clinical practice. Among others, fluorescence imaging has become one of the most commonly used imaging tools in pre-clinical research. The development of increasing numbers of suitable fluorescent dyes excitable in the visible to near-infrared wavelengths of the spectrum has significantly expanded the applicability of fluorescence imaging. This paper focuses on the potential applications and limitations of non-invasive imaging techniques in the field of drug delivery, especially in anticancer therapy. Fluorescent imaging at both the cellular and systemic levels is discussed in detail. Additionally, we explore the possibility for simultaneous treatment and imaging using theranostics and combinations of different imaging techniques, e.g., fluorescence imaging with computed tomography.
Collapse
|
14
|
Pera V, Brooks DH, Niedre M. Multiplexed fluorescence tomography with spectral and temporal data: demixing with intrinsic regularization. BIOMEDICAL OPTICS EXPRESS 2016; 7:111-131. [PMID: 26819822 PMCID: PMC4722896 DOI: 10.1364/boe.7.000111] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 09/29/2015] [Revised: 11/25/2015] [Accepted: 12/01/2015] [Indexed: 06/05/2023]
Abstract
We consider the joint use of spectral and temporal data for multiplexed fluorescence molecular tomography to enable high-throughput imaging of multiple fluorescent targets in bulk tissue. This is a challenging problem due to the narrow near-infrared diagnostic window and relatively broad emission spectra of common fluorophores, and the distortion ("redshift") that the fluorophore signals undergo as they propagate through tissue. We show through a Cramér-Rao lower bound analysis that demixing with spectral-temporal data could result in an order of magnitude improvement in performance over either modality alone. To cope with the resulting large data set, we propose a novel two-stage algorithm that decouples the demixing and tomographic reconstruction operations. In this work we concentrate on the demixing stage. We introduce an approach which incorporates ideas from sparse subspace clustering and compressed sensing and does not require a regularization parameter. We report on simulations in which we simultaneously demixed four fluorophores with closely overlapping spectral and temporal profiles in a 25 mm diameter cross-sectional area with a root-mean-square error of less than 3% per fluorophore, as well as on studies of sensitivity of the method to model mismatch.
Collapse
|
15
|
Ovanesyan Z, Mimun LC, Kumar GA, Yust BG, Dannangoda C, Martirosyan KS, Sardar DK. Depth-Resolved Multispectral Sub-Surface Imaging Using Multifunctional Upconversion Phosphors with Paramagnetic Properties. ACS APPLIED MATERIALS & INTERFACES 2015; 7:21465-21471. [PMID: 26322519 PMCID: PMC4597474 DOI: 10.1021/acsami.5b06491] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/04/2023]
Abstract
Molecular imaging is very promising technique used for surgical guidance, which requires advancements related to properties of imaging agents and subsequent data retrieval methods from measured multispectral images. In this article, an upconversion material is introduced for subsurface near-infrared imaging and for the depth recovery of the material embedded below the biological tissue. The results confirm significant correlation between the analytical depth estimate of the material under the tissue and the measured ratio of emitted light from the material at two different wavelengths. Experiments with biological tissue samples demonstrate depth resolved imaging using the rare earth doped multifunctional phosphors. In vitro tests reveal no significant toxicity, whereas the magnetic measurements of the phosphors show that the particles are suitable as magnetic resonance imaging agents. The confocal imaging of fibroblast cells with these phosphors reveals their potential for in vivo imaging. The depth-resolved imaging technique with such phosphors has broad implications for real-time intraoperative surgical guidance.
Collapse
Affiliation(s)
- Zaven Ovanesyan
- Department of Physics and Astronomy, The University of Texas at San Antonio, San Antonio, Texas 78249, United States
| | - L. Christopher Mimun
- Department of Physics and Astronomy, The University of Texas at San Antonio, San Antonio, Texas 78249, United States
| | - Gangadharan Ajith Kumar
- Department of Physics and Astronomy, The University of Texas at San Antonio, San Antonio, Texas 78249, United States
| | - Brian G. Yust
- Department of Physics, University of Texas at Rio Grande Valley, Edinburg, Texas 78539, United States
| | - Chamath Dannangoda
- Department of Physics and Astronomy, University of Texas at Rio Grande Valley, Brownsville, Texas 78520, United States
| | - Karen S. Martirosyan
- Department of Physics and Astronomy, University of Texas at Rio Grande Valley, Brownsville, Texas 78520, United States
| | - Dhiraj K. Sardar
- Department of Physics and Astronomy, The University of Texas at San Antonio, San Antonio, Texas 78249, United States
| |
Collapse
|
16
|
Individual variability analysis of fluorescence parameters measured in skin with different levels of nutritive blood flow. Med Eng Phys 2015; 37:574-83. [DOI: 10.1016/j.medengphy.2015.03.011] [Citation(s) in RCA: 25] [Impact Index Per Article: 2.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/11/2014] [Revised: 01/14/2015] [Accepted: 03/27/2015] [Indexed: 01/27/2023]
|
17
|
Jermyn M, Kolste K, Pichette J, Sheehy G, Angulo-Rodríguez L, Paulsen KD, Roberts DW, Wilson BC, Petrecca K, Leblond F. Macroscopic-imaging technique for subsurface quantification of near-infrared markers during surgery. JOURNAL OF BIOMEDICAL OPTICS 2015; 20:036014. [PMID: 25793562 PMCID: PMC4367847 DOI: 10.1117/1.jbo.20.3.036014] [Citation(s) in RCA: 10] [Impact Index Per Article: 1.1] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 01/14/2015] [Accepted: 03/03/2015] [Indexed: 05/20/2023]
Abstract
Obtaining accurate quantitative information on the concentration and distribution of fluorescent markers lying at a depth below the surface of optically turbid media, such as tissue, is a significant challenge. Here, we introduce a fluorescence reconstruction technique based on a diffusion light transport model that can be used during surgery, including guiding resection of brain tumors, for depth-resolved quantitative imaging of near-infrared fluorescent markers. Hyperspectral fluorescence images are used to compute a topographic map of the fluorophore distribution, which yields structural and optical constraints for a three-dimensional subsequent hyperspectral diffuse fluorescence reconstruction algorithm. Using the model fluorophore Alexa Fluor 647 and brain-like tissue phantoms, the technique yielded estimates of fluorophore concentration within ±25% of the true value to depths of 5 to 9 mm, depending on the concentration. The approach is practical for integration into a neurosurgical fluorescence microscope and has potential to further extend fluorescence-guided resection using objective and quantified metrics of the presence of residual tumor tissue.
Collapse
Affiliation(s)
- Michael Jermyn
- McGill University, Brain Tumour Research Centre, Montreal Neurological Institute and Hospital, Department of Neurology and Neurosurgery, 3801 University Street, Montreal, Quebec H3A 2B4, Canada
- Polytechnique Montreal, Department of Engineering Physics, CP 6079, Succ. Centre-Ville, Montreal, Quebec H3C 3A7, Canada
| | - Kolbein Kolste
- Dartmouth College, Thayer School of Engineering, 14 Engineering Drive, Hanover, New Hampshire 03755, United States
| | - Julien Pichette
- Polytechnique Montreal, Department of Engineering Physics, CP 6079, Succ. Centre-Ville, Montreal, Quebec H3C 3A7, Canada
| | - Guillaume Sheehy
- Polytechnique Montreal, Department of Engineering Physics, CP 6079, Succ. Centre-Ville, Montreal, Quebec H3C 3A7, Canada
| | - Leticia Angulo-Rodríguez
- Polytechnique Montreal, Department of Engineering Physics, CP 6079, Succ. Centre-Ville, Montreal, Quebec H3C 3A7, Canada
| | - Keith D. Paulsen
- Dartmouth College, Thayer School of Engineering, 14 Engineering Drive, Hanover, New Hampshire 03755, United States
| | - David W. Roberts
- Dartmouth-Hitchcock Medical Center, Section of Neurosurgery, Lebanon, New Hampshire 03756, United States
| | - Brian C. Wilson
- University of Toronto/University Health Network, Department of Medical Biophysics, 101 College Street, Toronto, Ontario M5G 1L7, Canada
| | - Kevin Petrecca
- McGill University, Brain Tumour Research Centre, Montreal Neurological Institute and Hospital, Department of Neurology and Neurosurgery, 3801 University Street, Montreal, Quebec H3A 2B4, Canada
| | - Frederic Leblond
- Polytechnique Montreal, Department of Engineering Physics, CP 6079, Succ. Centre-Ville, Montreal, Quebec H3C 3A7, Canada
- Address all correspondence to: Frederic Leblond, E-mail:
| |
Collapse
|
18
|
Kolste KK, Kanick SC, Valdés PA, Jermyn M, Wilson BC, Roberts DW, Paulsen KD, Leblond F. Macroscopic optical imaging technique for wide-field estimation of fluorescence depth in optically turbid media for application in brain tumor surgical guidance. JOURNAL OF BIOMEDICAL OPTICS 2015; 20:26002. [PMID: 25652704 PMCID: PMC4405086 DOI: 10.1117/1.jbo.20.2.026002] [Citation(s) in RCA: 7] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 10/08/2014] [Accepted: 01/05/2015] [Indexed: 05/13/2023]
Abstract
A diffuse imaging method is presented that enables wide-field estimation of the depth of fluorescent molecular markers in turbid media by quantifying the deformation of the detected fluorescence spectra due to the wavelength-dependent light attenuation by overlying tissue. This is achieved by measuring the ratio of the fluorescence at two wavelengths in combination with normalization techniques based on diffuse reflectance measurements to evaluate tissue attenuation variations for different depths. It is demonstrated that fluorescence topography can be achieved up to a 5 mm depth using a near-infrared dye with millimeter depth accuracy in turbid media having optical properties representative of normal brain tissue. Wide-field depth estimates are made using optical technology integrated onto a commercial surgical microscope, making this approach feasible for real-world applications.
Collapse
Affiliation(s)
- Kolbein K. Kolste
- Dartmouth College, Thayer School of Engineering, Hanover, 14 Engineering Drive, New Hampshire 03755, United States
| | - Stephen C. Kanick
- Dartmouth College, Thayer School of Engineering, Hanover, 14 Engineering Drive, New Hampshire 03755, United States
| | - Pablo A. Valdés
- Dartmouth College, Thayer School of Engineering, Hanover, 14 Engineering Drive, New Hampshire 03755, United States
- Dartmouth College, Geisel School of Medicine, Hanover, 1 Rope Ferry Road, New Hampshire 03755, United States
| | - Michael Jermyn
- Polytechnique Montreal, Engineering Physics Department, Montreal, Québec H3C 3A7, Canada
| | - Brian C. Wilson
- University of Toronto, Ontario Cancer Institute, 610 University Avenue, Toronto, Ontario M5G 2M9, Canada
| | - David W. Roberts
- Dartmouth-Hitchcock Medical Center, Section of Neurosurgery, 1 Medical Center Drive, Lebanon, New Hampshire 03756, United States
| | - Keith D. Paulsen
- Dartmouth College, Thayer School of Engineering, Hanover, 14 Engineering Drive, New Hampshire 03755, United States
| | - Frederic Leblond
- Polytechnique Montreal, Engineering Physics Department, Montreal, Québec H3C 3A7, Canada
- Address all correspondence to: Frederic Leblond, E-mail:
| |
Collapse
|
19
|
Zhou T, Ando T, Nakagawa K, Liao H, Kobayashi E, Sakuma I. Localizing fluorophore (centroid) inside a scattering medium by depth perturbation. JOURNAL OF BIOMEDICAL OPTICS 2015; 20:017003. [PMID: 25611868 DOI: 10.1117/1.jbo.20.1.017003] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 08/30/2014] [Accepted: 12/29/2014] [Indexed: 06/04/2023]
Abstract
Fluorescence molecular tomography (FMT) imaging can be used to determine the location, size, and biodistribution of fluorophore biomarkers inside tissues. Yet when using FMT in the reflectance geometry it is challenging to accurately localize fluorophores. A depth perturbation method is proposed to determine the centroid of fluorophore inside a tissue-like medium. Through superposition of a known thin optical phantom onto the medium surface, the fluorophore depth is deliberately perturbed and signal localization is improved in a stable way. We hypothesize that the fluorophore centroid can be better localized through use of this fluorescent intensity variation resulting from the depth perturbation. This hypothesis was tested in tissue-like phantoms. The results show that a small-size fluorophore inclusion (1.2 mm(3)volume, depth up to 4.8 mm) can be localized by the method with an error of 0.2 to 0.3 mm. The method is also proven to be capable of handling multiple fluorescent inclusion conditions with the assistance of other strategies. Additionally, our further studies showed that the method's performance in the presence of background fluorophores indicated that the small inclusion could be located at a 1.8 (3.8) mm depth with accurate localization only when its concentration was not <10 (100) times the background level.
Collapse
Affiliation(s)
- Tuo Zhou
- The University of Tokyo, Graduate School of Engineering, Department of Precision Engineering, 7-3-1 Hongo Bunkyoku, Tokyo 1138656, Japan
| | - Takehiro Ando
- The University of Tokyo, Graduate School of Engineering, Department of Precision Engineering, 7-3-1 Hongo Bunkyoku, Tokyo 1138656, Japan
| | - Keiichi Nakagawa
- The University of Tokyo, Graduate School of Engineering, Department of Precision Engineering, 7-3-1 Hongo Bunkyoku, Tokyo 1138656, Japan
| | - Hongen Liao
- Tsinghua University, School of Medicine, Department of Biomedical Engineering, 1 Qinghuayuan Haidian District, Beijing 100084, China
| | - Etsuko Kobayashi
- The University of Tokyo, Graduate School of Engineering, Department of Precision Engineering, 7-3-1 Hongo Bunkyoku, Tokyo 1138656, Japan
| | - Ichiro Sakuma
- The University of Tokyo, Graduate School of Engineering, Department of Precision Engineering, 7-3-1 Hongo Bunkyoku, Tokyo 1138656, Japan
| |
Collapse
|
20
|
Du Le VN, Nie Z, Hayward JE, Farrell TJ, Fang Q. Measurements of extrinsic fluorescence in Intralipid and polystyrene microspheres. BIOMEDICAL OPTICS EXPRESS 2014; 5:2726-35. [PMID: 25136497 PMCID: PMC4133001 DOI: 10.1364/boe.5.002726] [Citation(s) in RCA: 6] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 03/05/2014] [Revised: 05/27/2014] [Accepted: 07/16/2014] [Indexed: 05/21/2023]
Abstract
The fluorescence of Intralipid and polystyrene microspheres with sphere diameter of 1 µm at a representative lipid and microsphere concentration for simulation of mucosal tissue scattering has not been a subject of extensive experimental study. In order to elucidate the quantitative relationship between lipid and microsphere concentration and the respective fluorescent intensity, the extrinsic fluorescence spectra between 360 nm and 650 nm (step size of 5 nm) were measured at different lipid concentrations (from 0.25% to 5%) and different microsphere concentrations (0.00364, 0.0073, 0.0131 spheres per cubic micrometer) using laser excitation at 355 nm with pulse energy of 2.8 µJ. Current findings indicated that Intralipid has a broadband emission between 360 and 650 nm with a primary peak at 500 nm and a secondary peak at 450 nm while polystyrene microspheres have a single peak at 500 nm. In addition, for similar scattering properties the fluorescence of Intralipid solutions is approximately three-fold stronger than that of the microsphere solutions. Furthermore, Intralipid phantoms with lipid concentrations ~2% (simulating the bottom layer of mucosa) produce up to seven times stronger fluorescent emission than phantoms with lipid concentration ~0.25% (simulating the top layer of mucosa). The fluoresence decays of Intralipid and microsphere solutions were also recorded for estimation of fluorescence lifetime.
Collapse
Affiliation(s)
- Vinh Nguyen Du Le
- Medical Physics and Applied Radiation Sciences, McMaster University, Hamilton, Ontario, Canada
| | - Zhaojun Nie
- School of Biomedical Engineering, McMaster University, Hamilton, Ontario, Canada
| | - Joseph E. Hayward
- Medical Physics and Applied Radiation Sciences, McMaster University, Hamilton, Ontario, Canada
| | - Thomas J. Farrell
- Medical Physics and Applied Radiation Sciences, McMaster University, Hamilton, Ontario, Canada
| | - Qiyin Fang
- School of Biomedical Engineering, McMaster University, Hamilton, Ontario, Canada
- Department of Engineering Physics, McMaster University, Hamilton, Ontario, Canada
| |
Collapse
|
21
|
Valentine RM, Ibbotson SH, Wood K, Brown CTA, Moseley H. Modelling fluorescence in clinical photodynamic therapy. Photochem Photobiol Sci 2013; 12:203-13. [PMID: 23128146 DOI: 10.1039/c2pp25271f] [Citation(s) in RCA: 32] [Impact Index Per Article: 2.9] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/24/2023]
Abstract
Understanding the interactions of non-ionizing radiation with living organisms has been the focus of much research over recent decades. The complex nature of these interactions warrants development of theoretical and experimental studies to gain an insight into predicting and monitoring the success of photodynamic therapy (PDT) protocols. There is a major impetus towards evidence-based recommendations for patient diagnosis, treatment and management. Knowledge of the biophysical aspects of PDT is important for improving dosimetry protocols. Fluorescence in clinical PDT may be used to detect and diagnose pre-malignant and malignant conditions, while photobleaching can monitor changes in fluorescence during treatment. Combining empirical fluorescence photobleaching clinical data with computational modelling enables clinical PDT dosimetry protocols to be investigated with a view to optimising treatment regimes. We will discuss how Monte Carlo radiation transfer (MCRT) modelling has been intercalated in the field of fluorescence detection and PDT. In this paper we highlight important aspects of basic research in PDT by reporting on the current utilisation of fluorescence in clinical PDT from both a clinical and theoretical perspective. Understanding and knowledge of light propagation in biological tissue from these perspectives should have a positive impact on treatment planning.
Collapse
Affiliation(s)
- Ronan M Valentine
- Photobiology Unit, Ninewells Hospital and Medical School, University of Dundee, Dundee, DD1 9SY, UK.
| | | | | | | | | |
Collapse
|
22
|
Gerega A, Milej D, Weigl W, Botwicz M, Zolek N, Kacprzak M, Wierzejski W, Toczylowska B, Mayzner-Zawadzka E, Maniewski R, Liebert A. Multiwavelength time-resolved detection of fluorescence during the inflow of indocyanine green into the adult's brain. JOURNAL OF BIOMEDICAL OPTICS 2012; 17:087001. [PMID: 23224200 DOI: 10.1117/1.jbo.17.8.087001] [Citation(s) in RCA: 11] [Impact Index Per Article: 0.9] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/06/2023]
Abstract
Optical technique based on diffuse reflectance measurement combined with indocyanine green (ICG) bolus tracking is extensively tested as a method for clinical assessment of brain perfusion in adults at the bedside. Methodology of multiwavelength and time-resolved detection of fluorescence light excited in the ICG is presented and advantages of measurements at multiple wavelengths are discussed. Measurements were carried out: 1. on a physical homogeneous phantom to study the concentration dependence of the fluorescence signal, 2. on the phantom to simulate the dynamic inflow of ICG at different depths, and 3. in vivo on surface of the human head. Pattern of inflow and washout of ICG in the head of healthy volunteers after intravenous injection of the dye was observed for the first time with time-resolved instrumentation at multiple emission wavelengths. The multiwavelength detection of fluorescence signal confirms that at longer emission wavelengths, probability of reabsorption of the fluorescence light by the dye itself is reduced. Considering different light penetration depths at different wavelengths, and the pronounced reabsorption at longer wavelengths, the time-resolved multiwavelength technique may be useful in signal decomposition, leading to evaluation of extra- and intracerebral components of the measured signals.
Collapse
Affiliation(s)
- Anna Gerega
- Nalecz Institute of Biocybernetics and Biomedical Engineering Polish Academy of Sciences, Trojdena 4, 02-109 Warsaw, Poland.
| | | | | | | | | | | | | | | | | | | | | |
Collapse
|
23
|
Leblond F, Ovanesyan Z, Davis SC, Valdés PA, Kim A, Hartov A, Wilson BC, Pogue BW, Paulsen KD, Roberts DW. Analytic expression of fluorescence ratio detection correlates with depth in multi-spectral sub-surface imaging. Phys Med Biol 2011; 56:6823-37. [PMID: 21971201 DOI: 10.1088/0031-9155/56/21/005] [Citation(s) in RCA: 21] [Impact Index Per Article: 1.6] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/12/2022]
Abstract
Here we derived analytical solutions to diffuse light transport in biological tissue based on spectral deformation of diffused near-infrared measurements. These solutions provide a closed-form mathematical expression which predicts that the depth of a fluorescent molecule distribution is linearly related to the logarithm of the ratio of fluorescence at two different wavelengths. The slope and intercept values of the equation depend on the intrinsic values of absorption and reduced scattering of tissue. This linear behavior occurs if the following two conditions are satisfied: the depth is beyond a few millimeters and the tissue is relatively homogeneous. We present experimental measurements acquired with a broad-beam non-contact multi-spectral fluorescence imaging system using a hemoglobin-containing diffusive phantom. Preliminary results confirm that a significant correlation exists between the predicted depth of a distribution of protoporphyrin IX molecules and the measured ratio of fluorescence at two different wavelengths. These results suggest that depth assessment of fluorescence contrast can be achieved in fluorescence-guided surgery to allow improved intra-operative delineation of tumor margins.
Collapse
Affiliation(s)
- F Leblond
- Thayer School of Engineering, Dartmouth College, 8000 Cummings Hall, Hanover, NH 03755, USA.
| | | | | | | | | | | | | | | | | | | |
Collapse
|
24
|
Gerega A, Zolek N, Soltysinski T, Milej D, Sawosz P, Toczylowska B, Liebert A. Wavelength-resolved measurements of fluorescence lifetime of indocyanine green. JOURNAL OF BIOMEDICAL OPTICS 2011; 16:067010. [PMID: 21721831 DOI: 10.1117/1.3593386] [Citation(s) in RCA: 32] [Impact Index Per Article: 2.5] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/11/2023]
Abstract
We study fluorescence lifetime of indocyanine green (ICG) using femtosecond laser and sensitive detection based on time-correlated single-photon counting. A time-resolved multichannel spectral system is constructed and applied for determination of the fluorescence lifetime of the ICG in different solvents. Emission properties of ICG in water, milk, and 1% intralipid solution are investigated. Fluorescence of the fluorophore of different concentrations (in a range of 1.7-160 μM) dissolved in different solutions is excited by femtosecond pulses generated with the use of Ti:Sa laser tuned within the range of 740-790 nm. It is observed that fluorescence lifetime of ICG in water is 0.166 ± 0.02 ns and does not depend on excitation and emission wavelengths. We also show that for the diffusely scattering solvents (milk and intralipid), the lifetime may depend on the dye concentration (especially for large concentrations of ICG). This effect should be taken into account when analyzing changes in the mean time of arrival of fluorescence photons excited in ICG dissolved in such optically turbid media.
Collapse
Affiliation(s)
- Anna Gerega
- Polish Academy of Sciences, Institute of Biocybernetics and Biomedical Engineering, Trojdena 4, 02-109 Warsaw, Poland.
| | | | | | | | | | | | | |
Collapse
|
25
|
Zacharakis G, Favicchio R, Simantiraki M, Ripoll J. Spectroscopic detection improves multi-color quantification in fluorescence tomography. BIOMEDICAL OPTICS EXPRESS 2011; 2:431-9. [PMID: 21412449 PMCID: PMC3047349 DOI: 10.1364/boe.2.000431] [Citation(s) in RCA: 7] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 11/01/2010] [Revised: 12/30/2010] [Accepted: 01/25/2011] [Indexed: 05/22/2023]
Abstract
Simultaneous detection of several biological processes in vivo is a common requirement in biomedical and biological applications, and in order to address this issue the use of multiple fluorophores is usually the method of choice. Existing methodologies however, do not provide quantitative feedback of multiple fluorophore concentrations in small animals in vivo when their spectra overlap, especially when imaging the whole body in 3D. Here we present an approach where a spectroscopic module has been implemented into a custom-built Fluorescence Molecular Tomography (FMT) system. In contrast with other multispectral approaches, this multimodal imaging system is capable of recording the fluorescence spectra from each illumination point during a tomographic measurement. In situ spectral information can thus be extracted and used to improve the separation of overlapping signals associated with different fluorophores. The results of this new approach tested on both in vitro and in vivo experiments are presented, proving that accurate recovery of fluorophore concentrations can be obtained from multispectral tomography data even in the presence of high autofluorescence.
Collapse
Affiliation(s)
- Giannis Zacharakis
- Institute of Electronic Structure and Laser – Foundation for Research and Technology Hellas, N. Plastira 100, 71110 Heraklion Crete, Greece
| | - Rosy Favicchio
- Institute of Electronic Structure and Laser – Foundation for Research and Technology Hellas, N. Plastira 100, 71110 Heraklion Crete, Greece
| | - Maria Simantiraki
- Institute of Electronic Structure and Laser – Foundation for Research and Technology Hellas, N. Plastira 100, 71110 Heraklion Crete, Greece
| | - Jorge Ripoll
- Institute of Electronic Structure and Laser – Foundation for Research and Technology Hellas, N. Plastira 100, 71110 Heraklion Crete, Greece
| |
Collapse
|
26
|
Kim A, Roy M, Dadani FN, Wilson BC. Topographic mapping of subsurface fluorescent structures in tissue using multiwavelength excitation. JOURNAL OF BIOMEDICAL OPTICS 2010; 15:066026. [PMID: 21198200 PMCID: PMC3022586 DOI: 10.1117/1.3523369] [Citation(s) in RCA: 8] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/05/2023]
Abstract
Different colors of visible light penetrate to varying depths in tissue due to the wavelength dependence of tissue optical absorption and elastic scattering. We exploit this to map the contour of the closest surface of a buried fluorescent object. This uses a novel algorithm based on the diffusion theory description of light propagation in tissue at each excitation wavelength to derive metrics that define the depth of the top surface of the object. The algorithm was validated using a tissue-simulating phantom. It was then demonstrated in vivo by subsurface brain tumor topography in a rodent model, using the fluorescence signal from protoporphyrin IX that is preferentially synthesized within malignant cells following systemic application of aminolevulinic acid. Comparisons to histomorphometry in the brain post mortem show the spatial accuracy of the technique. This method has potential for fluorescence image-guided tumor surgery, as well as other biomedical and nonbiological applications in subsurface sensing.
Collapse
Affiliation(s)
- Anthony Kim
- University of Toronto, Department of Medical Biophysics, Toronto, Ontario, Canada
| | | | | | | |
Collapse
|
27
|
Joshi AA, Chaudhari AJ, Li C, Dutta J, Cherry SR, Shattuck DW, Toga AW, Leahy RM. DigiWarp: a method for deformable mouse atlas warping to surface topographic data. Phys Med Biol 2010; 55:6197-214. [PMID: 20885019 DOI: 10.1088/0031-9155/55/20/011] [Citation(s) in RCA: 18] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/11/2022]
Abstract
For pre-clinical bioluminescence or fluorescence optical tomography, the animal's surface topography and internal anatomy need to be estimated for improving the quantitative accuracy of reconstructed images. The animal's surface profile can be measured by all-optical systems, but estimation of the internal anatomy using optical techniques is non-trivial. A 3D anatomical mouse atlas may be warped to the estimated surface. However, fitting an atlas to surface topography data is challenging because of variations in the posture and morphology of imaged mice. In addition, acquisition of partial data (for example, from limited views or with limited sampling) can make the warping problem ill-conditioned. Here, we present a method for fitting a deformable mouse atlas to surface topographic range data acquired by an optical system. As an initialization procedure, we match the posture of the atlas to the posture of the mouse being imaged using landmark constraints. The asymmetric L(2) pseudo-distance between the atlas surface and the mouse surface is then minimized in order to register two data sets. A Laplacian prior is used to ensure smoothness of the surface warping field. Once the atlas surface is normalized to match the range data, the internal anatomy is transformed using elastic energy minimization. We present results from performance evaluation studies of our method where we have measured the volumetric overlap between the internal organs delineated directly from MRI or CT and those estimated by our proposed warping scheme. Computed Dice coefficients indicate excellent overlap in the brain and the heart, with fair agreement in the kidneys and the bladder.
Collapse
Affiliation(s)
- Anand A Joshi
- Laboratory of Neuro Imaging, UCLA School of Medicine, Los Angeles, CA 90095, USA.
| | | | | | | | | | | | | | | |
Collapse
|
28
|
Leblond F, Davis SC, Valdés PA, Pogue BW. Pre-clinical whole-body fluorescence imaging: Review of instruments, methods and applications. JOURNAL OF PHOTOCHEMISTRY AND PHOTOBIOLOGY B-BIOLOGY 2009; 98:77-94. [PMID: 20031443 DOI: 10.1016/j.jphotobiol.2009.11.007] [Citation(s) in RCA: 362] [Impact Index Per Article: 24.1] [Reference Citation Analysis] [Abstract] [Subscribe] [Scholar Register] [Received: 07/22/2009] [Revised: 11/16/2009] [Accepted: 11/20/2009] [Indexed: 01/07/2023]
Abstract
Fluorescence sampling of cellular function is widely used in all aspects of biology, allowing the visualization of cellular and sub-cellular biological processes with spatial resolutions in the range from nanometers up to centimeters. Imaging of fluorescence in vivo has become the most commonly used radiological tool in all pre-clinical work. In the last decade, full-body pre-clinical imaging systems have emerged with a wide range of utilities and niche application areas. The range of fluorescent probes that can be excited in the visible to near-infrared part of the electromagnetic spectrum continues to expand, with the most value for in vivo use being beyond the 630 nm wavelength, because the absorption of light sharply decreases. Whole-body in vivo fluorescence imaging has not yet reached a state of maturity that allows its routine use in the scope of large-scale pre-clinical studies. This is in part due to an incomplete understanding of what the actual fundamental capabilities and limitations of this imaging modality are. However, progress is continuously being made in research laboratories pushing the limits of the approach to consistently improve its performance in terms of spatial resolution, sensitivity and quantification. This paper reviews this imaging technology with a particular emphasis on its potential uses and limitations, the required instrumentation, and the possible imaging geometries and applications. A detailed account of the main commercially available systems is provided as well as some perspective relating to the future of the technology development. Although the vast majority of applications of in vivo small animal imaging are based on epi-illumination planar imaging, the future success of the method relies heavily on the design of novel imaging systems based on state-of-the-art optical technology used in conjunction with high spatial resolution structural modalities such as MRI, CT or ultrasound.
Collapse
Affiliation(s)
- Frederic Leblond
- Thayer School of Engineering, Dartmouth College, Hanover, NH 03755, USA.
| | | | | | | |
Collapse
|
29
|
Chaudhari AJ, Ahn S, Levenson R, Badawi RD, Cherry SR, Leahy RM. Excitation spectroscopy in multispectral optical fluorescence tomography: methodology, feasibility and computer simulation studies. Phys Med Biol 2009; 54:4687-704. [PMID: 19590118 DOI: 10.1088/0031-9155/54/15/004] [Citation(s) in RCA: 26] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/31/2022]
Abstract
Molecular probes used for in vivo optical fluorescence tomography (OFT) studies in small animals are typically chosen such that their emission spectra lie in the 680-850 nm wavelength range. This is because tissue attenuation in this spectral band is relatively low, allowing optical photons even from deep sites in tissue to reach the animal surface and consequently be detected by a CCD camera. The wavelength dependence of tissue optical properties within the 680-850 nm band can be exploited for emitted light by measuring fluorescent data via multispectral approaches and incorporating the spectral dependence of these optical properties into the OFT inverse problem-that of reconstructing underlying 3D fluorescent probe distributions from optical data collected on the animal surface. However, in the aforementioned spectral band, due to only small variations in the tissue optical properties, multispectral emission data, though superior for image reconstruction compared to achromatic data, tend to be somewhat redundant. A different spectral approach for OFT is to capitalize on the larger variations in the optical properties of tissue for excitation photons than for the emission photons by using excitation at multiple wavelengths as a means of decoding source depth in tissue. The full potential of spectral approaches in OFT can be realized by a synergistic combination of these two approaches, that is, exciting the underlying fluorescent probe at multiple wavelengths and measuring emission data multispectrally. In this paper, we describe a method that incorporates both excitation and emission spectral information into the OFT inverse problem. We describe a linear algebraic formulation of the multiple wavelength illumination-multispectral detection forward model for OFT and compare it to models that use only excitation at multiple wavelengths or those that use only multispectral detection techniques. This study is carried out in a realistic inhomogeneous mouse atlas using singular value decomposition and analysis of reconstructed spatial resolution versus noise. For simplicity, quantitative results have been shown for one representative fluorescent probe (Alexa 700) and effects due to tissue autofluorescence have not been taken into account. We also demonstrate the performance of our method for 3D reconstruction of tumors in a simulated mouse model of metastatic human hepatocellular carcinoma.
Collapse
Affiliation(s)
- Abhijit J Chaudhari
- Department of Biomedical Engineering, University of California-Davis, Davis, CA 95616, USA.
| | | | | | | | | | | |
Collapse
|
30
|
Davis SC, Pogue BW, Tuttle SB, Dehghani H, Paulsen KD. Spectral distortion in diffuse molecular luminescence tomography in turbid media. JOURNAL OF APPLIED PHYSICS 2009; 105:102024. [PMID: 20157444 PMCID: PMC2821414 DOI: 10.1063/1.3116130] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 03/31/2008] [Accepted: 08/07/2008] [Indexed: 05/28/2023]
Abstract
The influence of tissue optical properties on the shape of near-infrared (NIR) fluorescence emission spectra propagating through multiple centimeters of tissue-like media was investigated. Fluorescence emission spectra measured from 6 cm homogeneous tissue-simulating phantoms show dramatic spectral distortion which results in emission peak shifts of up to 60 nm in wavelength. Measured spectral shapes are highly dependent on the photon path length and the scattered photon field in the NIR amplifies the wavelength-dependent absorption of the fluorescence spectra. Simulations of the peak propagation using diffusion modeling describe the experimental observations and confirm the path length dependence of fluorescence emission spectra. Spectral changes are largest for long path length measurements and thus will be most important in human tomography studies in the NIR. Spectrally resolved detection strategies are required to detect and interpret these effects which may otherwise produce erroneous intensity measurements. This observed phenomenon is analogous to beam hardening in x-ray tomography, which can lead to image artifacts without appropriate compensation. The peak shift toward longer wavelengths, and therefore lower energy photons, observed for NIR luminescent signals propagating through tissue may readily be described as a beam softening phenomenon.
Collapse
|
31
|
Kortun C, Hijazi YR, Arifler D. Combined Monte Carlo and finite-difference time-domain modeling for biophotonic analysis: implications on reflectance-based diagnosis of epithelial precancer. JOURNAL OF BIOMEDICAL OPTICS 2008; 13:034014. [PMID: 18601559 DOI: 10.1117/1.2939405] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/26/2023]
Abstract
Monte Carlo (MC) modeling of photon transport in tissues is generally performed using simplified functions that only approximate the angular scattering properties of tissue constituents. However, such approximations may not be sufficient for fully characterizing tissue scatterers such as cells. Finite-difference time-domain (FDTD) modeling provides a flexible approach to compute realistic tissue phase functions that describe probability of scattering at different angles. We describe a computational framework that combines MC and FDTD modeling, and allows random sampling of scattering directions from FDTD phase functions. We carry out simulations to assess the influence of incorporating realistic FDTD phase functions on modeling spectroscopic reflectance signals obtained from normal and precancerous epithelial tissues. Simulations employ various fiber optic probe designs to analyze the sensitivity of different probe geometries to FDTD-generated phase functions. Combined MC/FDTD modeling results indicate that the form of the phase function used is an important factor in determining the reflectance profile of tissues, and detected reflectance intensity can change up to approximately 30% when a realistic FDTD phase function is used instead of an approximating function. The results presented need to be taken into account when developing photon propagation models or implementing inverse algorithms to extract optical properties from measurements.
Collapse
Affiliation(s)
- Cemre Kortun
- University College London, Department of Medical Physics and Bioengineering, London WC1E 6BT, United Kingdom
| | | | | |
Collapse
|
32
|
Brambilla M, Spinelli L, Pifferi A, Torricelli A, Cubeddu R. Time-resolved scanning system for double reflectance and transmittance fluorescence imaging of diffusive media. THE REVIEW OF SCIENTIFIC INSTRUMENTS 2008; 79:013103. [PMID: 18248018 DOI: 10.1063/1.2828054] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/03/2023]
Abstract
In this work we present a novel diffuse fluorescence imaging system, based on time-resolved two-wavelength double reflectance and transmittance setup for slab geometry samples. We describe the hardware setup, showing its compactness and versatility and show the results on preliminary measurements on phantoms. We fully assessed the performances and the dynamic ranges of the system. We validated its ability of recovering the optical properties of the bulk medium, for samples with scattering and absorption coefficients similar to those of biological tissues and with thicknesses of about 2 cm. Moreover we assess the linearity of the recorded signals against the fluorophore concentration, when it is homogeneously diffused in the phantom or concentrated inside a sealed inclusion. In both cases we observe again a fairly good linearity, over three orders of magnitude, from 10(-8)M to 10(-5)M. With the fluorescent inclusion we were also able to assess the imaging capabilities of the system, in terms of spatial resolution, which we appraise in about 3 mm, and in terms of imaging sensitivity (the smallest quantity of fluorescent dye distinguishable from the homogeneous background), settled to 200 fmol. Since the recorded data are time resolved, we could also estimate the dye fluorescence lifetime and build early and late time gate images. We finally discuss some of the criticalities of the proposed system and the developments we are currently carrying on in order to adapt it for in vivo measurements.
Collapse
Affiliation(s)
- Marco Brambilla
- IIT, ULTRAS-INFM-CNR and IFN-CNR, Politecnico di Milano, Dipartimento di Fisica, Piazza Leonardo da Vinci 32, I-20133 Milan, Italy.
| | | | | | | | | |
Collapse
|
33
|
Pan T, Rasmussen JC, Lee JH, Sevick-Muraca EM. Monte Carlo simulation of time-dependent, transport-limited fluorescent boundary measurements in frequency domain. Med Phys 2007; 34:1298-311. [PMID: 17500461 DOI: 10.1118/1.2710549] [Citation(s) in RCA: 7] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/07/2022] Open
Abstract
Recently, we have presented and experimentally validated a unique numerical solver of the coupled radiative transfer equations (RTEs) for rapidly computing time-dependent excitation and fluorescent light propagation in small animal tomography. Herein, we present a time-dependent Monte Carlo algorithm to validate the forward RTE solver and investigate the impact of physical parameters upon transport-limited measurements in order to best direct the development of the RTE solver for optical tomography. Experimentally, the Monte Carlo simulations for both transport-limited and diffusion-limited propagations are validated using frequency domain photon migration measurements for 1.0%, 0.5%, and 0.2% intralipid solutions containing 1 microM indocyanine green in a 49 cm3 cylindrical phantom corresponding to the small volume employed in small animal tomography. The comparisons between Monte Carlo simulations and the numerical solutions result in mean percent error in amplitude and the phase shift less than 5.0% and 0.7 degrees, respectively, at excitation and emission wavelengths for varying anisotropic factors, lifetimes, and modulation frequencies. Monte Carlo simulations indicate that the accuracy of the forward model is enhanced using (i) suitable source models of photon delivery, (ii) accurate anisotropic factors, and (iii) accurate acceptance angles of collected photons. Monte Carlo simulations also show that the accuracy of the diffusion approximation in the small phantom depends upon (i) the ratio d(phantom)/l(tr), where d(phantom) is the phantom diameter and l(tr) is the transport mean free path; and (ii) the anisotropic factor of the medium. The Monte Carlo simulations validates and guides the future development of an appropriate RTE solver for deployment in small animal optical tomography.
Collapse
Affiliation(s)
- Tianshu Pan
- Department of Radiology, Baylor College of Medicine, One Baylor Plaza, MS: BCM 360, Houston, Texas 77030, USA
| | | | | | | |
Collapse
|
34
|
Gebhart SC, Majumder SK, Mahadevan-Jansen A. Comparison of spectral variation from spectroscopy to spectral imaging. APPLIED OPTICS 2007; 46:1343-60. [PMID: 17318255 DOI: 10.1364/ao.46.001343] [Citation(s) in RCA: 14] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/08/2023]
Abstract
Optical biopsy has been shown to discriminate between normal and diseased tissue with high sensitivity and specificity. Fiber-optic probe-based spectroscopy systems do not provide the necessary spatial information to guide therapy effectively, ultimately requiring a transition from probe-based spectroscopy to spectral imaging. The effect of such a transition on fluorescence and diffuse reflectance line shape is investigated. Inherent differences in spectral line shape between spectroscopy and imaging are characterized and many of these differences may be attributed to a shift in illumination-collection geometry between the two systems. Sensitivity of the line-shape disparity is characterized with respect to changes in sample absorption and scattering as well as to changes in various parameters of the fiber-optic probe design (e.g., fiber diameter, beam steering). Differences in spectral line shape are described in terms of the relative relationship between the light diffusion within the tissue and the distribution of source-detector separation distances for the probe-based and imaging illumination-collection geometries. Monte Carlo simulation is used to determine fiber configurations that minimize the line-shape disparity between the two systems. In conclusion, we predict that fiber-optic probe designs that mimic a spectral imaging geometry and spectral imaging systems designed to emulate a probe-based geometry will be difficult to implement, pointing toward a posteriori correction for illumination-collection geometry to reconcile imaging and probe-based spectral line shapes or independent evaluation of tissue discrimination accuracy for probe-based and spectral imaging systems.
Collapse
Affiliation(s)
- Steven C Gebhart
- Department of Biomedical Engineering, Vandervilt University, Nashville, Tennessee 32735, USA.
| | | | | |
Collapse
|
35
|
Abstract
There is a wealth of new fluorescent reporter technologies for tagging of many cellular and subcellular processes in vivo. This imposed contrast is now captured with an increasing number of available imaging methods that offer new ways to visualize and quantify fluorescent markers distributed in tissues. This is an evolving field of imaging sciences that has already achieved major advances but is also facing important challenges. It is nevertheless well poised to significantly impact the ways of biological research, drug discovery, and clinical practice in the years to come. Herein, the most pertinent technologies associated with in vivo noninvasive or minimally invasive fluorescence imaging of tissues are summarized. Focus is given to small-animal imaging. However, while a broad spectrum of fluorescence reporter technologies and imaging methods are outlined, as necessary for biomedical research, and clinical translation as well.
Collapse
Affiliation(s)
- Vasilis Ntziachristos
- Laboratory for Bio-Optics and Molecular Imaging, Center for Molecular Imaging Research, Massachusetts General Hospital, Harvard Medical School, Boston, Massachusetts 02114, USA.
| |
Collapse
|
36
|
Gupta S, Raja VLNS, Pradhan A. Simultaneous extraction of optical transport parameters and intrinsic fluorescence of tissue mimicking model media using a spatially resolved fluorescence technique. APPLIED OPTICS 2006; 45:7529-37. [PMID: 16983443 DOI: 10.1364/ao.45.007529] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/11/2023]
Abstract
We present a method based on spatially resolved fluorescence measurement for the simultaneous estimation of optical transport parameters, namely, the reduced scattering coefficient (micro s'), the absorption coefficient (micro a), and the intrinsic fluorescence spectra from turbid media. The accuracy of this approach was tested by conducting studies on a series of tissue-simulating phantoms with known optical transport properties. The estimated relative error in the values for micro s' and micro a using this technique was found to be < or =10%. Furthermore, the line shape and intensity of the intrinsic fluorescence recovered by using this approach were observed to be free from the distorting effects of the wavelength-dependent absorption and scattering properties of the medium, and they were in excellent agreement with the directly measured intrinsic fluorescence spectra of the fluorophores.
Collapse
|
37
|
Pogue BW, Patterson MS. Review of tissue simulating phantoms for optical spectroscopy, imaging and dosimetry. JOURNAL OF BIOMEDICAL OPTICS 2006; 11:041102. [PMID: 16965130 DOI: 10.1117/1.2335429] [Citation(s) in RCA: 370] [Impact Index Per Article: 20.6] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/11/2023]
Abstract
Optical spectroscopy, imaging, and therapy tissue phantoms must have the scattering and absorption properties that are characteristic of human tissues, and over the past few decades, many useful models have been created. In this work, an overview of their composition and properties is outlined, by separating matrix, scattering, and absorbing materials, and discussing the benefits and weaknesses in each category. Matrix materials typically are water, gelatin, agar, polyester or epoxy and polyurethane resin, room-temperature vulcanizing (RTV) silicone, or polyvinyl alcohol gels. The water and hydrogel materials provide a soft medium that is biologically and biochemically compatible with addition of organic molecules, and are optimal for scientific laboratory studies. Polyester, polyurethane, and silicone phantoms are essentially permanent matrix compositions that are suitable for routine calibration and testing of established systems. The most common three choices for scatters have been: (1.) lipid based emulsions, (2.) titanium or aluminum oxide powders, and (3.) polymer microspheres. The choice of absorbers varies widely from hemoglobin and cells for biological simulation, to molecular dyes and ink as less biological but more stable absorbers. This review is an attempt to indicate which sets of phantoms are optimal for specific applications, and provide links to studies that characterize main phantom material properties and recipes.
Collapse
Affiliation(s)
- Brian W Pogue
- Dartmouth College, Thayer School of Engineering, Hanover, New Hampshire 03755, USA.
| | | |
Collapse
|
38
|
Zavattini G, Vecchi S, Mitchell G, Weisser U, Leahy RM, Pichler BJ, Smith DJ, Cherry SR. A hyperspectral fluorescence system for 3Din vivooptical imaging. Phys Med Biol 2006; 51:2029-43. [PMID: 16585843 DOI: 10.1088/0031-9155/51/8/005] [Citation(s) in RCA: 33] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/03/2023]
Abstract
In vivo optical instruments designed for small animal imaging generally measure the integrated light intensity across a broad band of wavelengths, or make measurements at a small number of selected wavelengths, and primarily use any spectral information to characterize and remove autofluorescence. We have developed a flexible hyperspectral imaging instrument to explore the use of spectral information to determine the 3D source location for in vivo fluorescence imaging applications. We hypothesize that the spectral distribution of the emitted fluorescence signal can be used to provide additional information to 3D reconstruction algorithms being developed for optical tomography. To test this hypothesis, we have designed and built an in vivo hyperspectral imaging system, which can acquire data from 400 to 1000 nm with 3 nm spectral resolution and which is flexible enough to allow the testing of a wide range of illumination and detection geometries. It also has the capability to generate a surface contour map of the animal for input into the reconstruction process. In this paper, we present the design of the system, demonstrate the depth dependence of the spectral signal in phantoms and show the ability to reconstruct 3D source locations using the spectral data in a simple phantom. We also characterize the basic performance of the imaging system.
Collapse
Affiliation(s)
- Guido Zavattini
- Department of Biomedical Engineering, University of California-Davis, One Shields Avenue, Davis, CA 95616, USA
| | | | | | | | | | | | | | | |
Collapse
|
39
|
Svensson T, Swartling J, Taroni P, Torricelli A, Lindblom P, Ingvar C, Andersson-Engels S. Characterization of normal breast tissue heterogeneity using time-resolved near-infrared spectroscopy. Phys Med Biol 2005; 50:2559-71. [PMID: 15901954 DOI: 10.1088/0031-9155/50/11/008] [Citation(s) in RCA: 45] [Impact Index Per Article: 2.4] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/12/2022]
Abstract
In recent years, extensive efforts have been made in developing near-infrared optical techniques to be used in detection and diagnosis of breast cancer. Variations in optical properties of normal breast tissue set limits to the performance of such techniques and must therefore be thoroughly examined. In this paper, we present intra- and intersubject as well as contralateral variations of optical and physiological properties in breast tissue as measured by using four-wavelength time-resolved spectroscopy (at 660, 786, 916 and 974 nm). In total, 36 volunteers were examined at five regions at each breast. Optical properties (absorption, mu(a), and reduced scattering, mu'(s)) are derived by employing diffusion theory. The use of four wavelengths enables determination of main tissue chromophores (haemoglobin, water and lipids) as well as haemoglobin oxygenation. Variations in all evaluated properties seen over the entire breast are approximately twice those for small-scale heterogeneity (millimetre scale). Intrasubject variations in optical properties are almost in all cases below 20% for mu'(s), and 40% for mu(a). Overall variations in water, lipid and haemoglobin concentrations are all in the order of 20%. Oxygenation is the least variable of the quantities evaluated, overall intrasubject variations being 6% on average. Extracted physiological properties confirm differences between pre- and post-menopausal breast tissue. Results do not indicate systematic differences between left and right breasts.
Collapse
Affiliation(s)
- Tomas Svensson
- Department of Physics, Lund Institute of Technology, Box 118, SE-221 00 Lund, Sweden.
| | | | | | | | | | | | | |
Collapse
|
40
|
af Klinteberg C, Pifferi A, Andersson-Engels S, Cubeddu R, Svanberg S. In vivo absorption spectroscopy of tumor sensitizers with femtosecond white light. APPLIED OPTICS 2005; 44:2213-20. [PMID: 15835366 DOI: 10.1364/ao.44.002213] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/11/2023]
Abstract
A system based on a femtosecond white-light continuum and a streak camera was used for recordings of the in vivo absorption spectra of the tumor-seeking agent disulphonated aluminum phthalocyanine. Measurements for different drug doses were performed on tumor tissue (muscle-implanted adenocarcinoma) and normal muscle tissue in rats. It was found that the shape of the spectrum is tissue dependent. The peak of the absorption spectrum is blueshifted in tumor tissue as compared with the muscle. Thus the contrast in the drug-related absorption can be altered by up to a factor of 2 from the primary drug molecular-concentration contrast between normal muscle and tumor by the proper selection of the illumination wavelength.
Collapse
|