A review of optical breast imaging: Multi-modality systems for breast cancer diagnosis. Eur J Radiol 2020; 129:109067. [PMID: 32497943 DOI: 10.1016/j.ejrad.2020.109067] [Citation(s) in RCA: 15] [Impact Index Per Article: 3.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/07/2020] [Revised: 05/04/2020] [Accepted: 05/09/2020] [Indexed: 11/24/2022]
Abstract
This review of optical breast imaging describes basic physical and system principles and summarizes technological evolution with a focus on multi-modality platforms and recent clinical trial results. Ultrasound-guided diffuse optical tomography and co-registered ultrasound and photoacoustic imaging systems are emphasized as models of state of the art optical technology that are most conducive to clinical translation.
Collapse
|
2
|
Krishnamurthy N, Kainerstorfer JM, Sassaroli A, Anderson PG, Fantini S. Broadband optical mammography instrument for depth-resolved imaging and local dynamic measurements. THE REVIEW OF SCIENTIFIC INSTRUMENTS 2016; 87:024302. [PMID: 26931870 PMCID: PMC4769268 DOI: 10.1063/1.4941777] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 10/29/2015] [Accepted: 01/30/2016] [Indexed: 06/05/2023]
Abstract
We present a continuous-wave instrument for non-invasive diffuse optical imaging of the breast in a parallel-plate transmission geometry. The instrument measures continuous spectra in the wavelength range 650-1000 nm, with an intensity noise level <1.5% and a spatial sampling rate of 5 points/cm in the x- and y-directions. We collect the optical transmission at four locations, one collinear and three offset with respect to the illumination optical fiber, to recover the depth of optical inhomogeneities in the tissue. We imaged a tissue-like, breast shaped, silicone phantom (6 cm thick) with two embedded absorbing structures: a black circle (1.7 cm in diameter) and a black stripe (3 mm wide), designed to mimic a tumor and a blood vessel, respectively. The use of a spatially multiplexed detection scheme allows for the generation of on-axis and off-axis projection images simultaneously, as opposed to requiring multiple scans, thus decreasing scan-time and motion artifacts. This technique localizes detected inhomogeneities in 3D and accurately assigns their depth to within 1 mm in the ideal conditions of otherwise homogeneous tissue-like phantoms. We also measured induced hemodynamic changes in the breast of a healthy human subject at a selected location (no scanning). We applied a cyclic, arterial blood pressure perturbation by alternating inflation (to a pressure of 200 mmHg) and deflation of a pneumatic cuff around the subject's thigh at a frequency of 0.05 Hz, and measured oscillations with amplitudes up to 1 μM and 0.2 μM in the tissue concentrations of oxyhemoglobin and deoxyhemoglobin, respectively. These hemodynamic oscillations provide information about the vascular structure and functional integrity in tissue, and may be used to assess healthy or abnormal perfusion in a clinical setting.
Collapse
Affiliation(s)
- Nishanth Krishnamurthy
- Department of Biomedical Engineering, Tufts University, Medford, Massachusetts 02155, USA
| | - Jana M Kainerstorfer
- Department of Biomedical Engineering, Tufts University, Medford, Massachusetts 02155, USA
| | - Angelo Sassaroli
- Department of Biomedical Engineering, Tufts University, Medford, Massachusetts 02155, USA
| | - Pamela G Anderson
- Department of Biomedical Engineering, Tufts University, Medford, Massachusetts 02155, USA
| | - Sergio Fantini
- Department of Biomedical Engineering, Tufts University, Medford, Massachusetts 02155, USA
| |
Collapse
|
3
|
Roblyer D, O'Sullivan TD, Warren RV, Tromberg B. Feasibility of Direct Digital Sampling for Diffuse Optical Frequency Domain Spectroscopy in Tissue. MEASUREMENT SCIENCE & TECHNOLOGY 2013; 24:045501. [PMID: 24678143 PMCID: PMC3963501 DOI: 10.1088/0957-0233/24/4/045501] [Citation(s) in RCA: 8] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/18/2023]
Abstract
Frequency domain optical spectroscopy in the diffusive regime is currently being investigated for biomedical applications including tumor detection, therapy monitoring, exercise metabolism, and others. Analog homodyne or heterodyne detection of sinusoidally modulated signals have been the predominant method for measuring phase and amplitude of photon density waves that have traversed through tissue. Here we demonstrate the feasibility of utilizing direct digital sampling of modulated signals using a 3.6 Gigasample/second 12 bit Analog to Digital Converter. Digitally synthesized modulated signals between 50MHz and 400MHz were measured on tissue simulating phantoms at six near-infrared wavelengths. An amplitude and phase precision of 1% and 0.6 degrees were achieved during drift tests. Amplitude, phase, scattering and absorption values were compared with a well-characterized network analyzer based diffuse optical device. Measured optical properties measured with both systems were within 3.6% for absorption and 2.8% for scattering over a range of biologically relevant values. Direct digital sampling represents a viable method for frequency domain diffuse optical spectroscopy and has the potential to reduce system complexity, size, and cost.
Collapse
Affiliation(s)
- Darren Roblyer
- Department of Biomedical Engineering, Boston University, 44 Cummington Mall, Boston, MA 02115 ; Laser Microbeam and Medical Program (LAMMP), Beckman Laser Institute and Medical Clinic, University of California, Irvine
| | - Thomas D O'Sullivan
- Laser Microbeam and Medical Program (LAMMP), Beckman Laser Institute and Medical Clinic, University of California, Irvine
| | - Robert V Warren
- Laser Microbeam and Medical Program (LAMMP), Beckman Laser Institute and Medical Clinic, University of California, Irvine
| | - Bruce Tromberg
- Laser Microbeam and Medical Program (LAMMP), Beckman Laser Institute and Medical Clinic, University of California, Irvine
| |
Collapse
|
4
|
Kainerstorfer JM, Yu Y, Weliwitigoda G, Anderson PG, Sassaroli A, Fantini S. Depth discrimination in diffuse optical transmission imaging by planar scanning off-axis fibers: initial applications to optical mammography. PLoS One 2013; 8:e58510. [PMID: 23516494 PMCID: PMC3597739 DOI: 10.1371/journal.pone.0058510] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/11/2012] [Accepted: 02/05/2013] [Indexed: 11/17/2022] Open
Abstract
We present a method for depth discrimination in parallel-plate, transmission mode, diffuse optical imaging. The method is based on scanning a set of detector pairs, where the two detectors in each pair are separated by a distance δDi along direction δ D i within the x-y scanning plane. A given optical inhomogeneity appears shifted by αi δ D i (with 0≤ αi ≤1) in the images collected with the two detection fibers of the i-th pair. Such a spatial shift can be translated into a measurement of the depth z of the inhomogeneity, and the depth measurements based on each detector pair are combined into a specially designed weighted average. This depth assessment is demonstrated on tissue-like phantoms for simple inhomogeneities such as straight rods in single-rod or multiple-rod configurations, and for more complex curved structures which mimic blood vessels in the female breast. In these phantom tests, the method has recovered the depth of single inhomogeneities in the central position of the phantom to within 4 mm of their actual value, and within 7 mm for more superficial inhomogeneities, where the thickness of the phantom was 65 mm. The application of this method to more complex images, such as optical mammograms, requires a robust approach to identify corresponding structures in the images collected with the two detectors of a given pair. To this aim, we propose an approach based on the inner product of the skeleton images collected with the two detectors of each pair, and we present an application of this approach to optical in vivo images of the female breast. This depth discrimination method can enhance the spatial information content of 2D projection images of the breast by assessing the depth of detected structures, and by allowing for 3D localization of breast tumors.
Collapse
Affiliation(s)
- Jana M Kainerstorfer
- Department of Biomedical Engineering, Tufts University, Medford, Massachusetts, United States of America.
| | | | | | | | | | | |
Collapse
|
5
|
Choe R, Durduran T. Diffuse Optical Monitoring of the Neoadjuvant Breast Cancer Therapy. IEEE JOURNAL OF SELECTED TOPICS IN QUANTUM ELECTRONICS : A PUBLICATION OF THE IEEE LASERS AND ELECTRO-OPTICS SOCIETY 2012; 18:1367-1386. [PMID: 23243386 PMCID: PMC3521564 DOI: 10.1109/jstqe.2011.2177963] [Citation(s) in RCA: 43] [Impact Index Per Article: 3.6] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/19/2023]
Abstract
Recent advances in the use of diffuse optical techniques for monitoring the hemodynamic, metabolic and physiological signatures of the neoadjuvant breast cancer therapy effectiveness is critically reviewed. An extensive discussion of the state-of-theart diffuse optical mammography is presented alongside a discussion of the current approaches to breast cancer therapies. Overall, the diffuse optics field is growing rapidly with a great deal of promise to fill an important niche in the current approaches to monitor, predict and personalize neoadjuvant breast cancer therapies.
Collapse
Affiliation(s)
- Regine Choe
- Department of Biomedical Engineering, University of Rochester, Rochester, NY, USA;
| | - Turgut Durduran
- ICFO- Institut de Ciències Fotòniques, Mediterranean Technology Park, 08860, Barcelona, Spain;
| |
Collapse
|
6
|
Heijblom M, Klaase JM, van den Engh FM, van Leeuwen TG, Steenbergen W, Manohar S. Imaging Tumor Vascularization for Detection and Diagnosis of Breast Cancer. Technol Cancer Res Treat 2011; 10:607-23. [DOI: 10.7785/tcrt.2012.500227] [Citation(s) in RCA: 45] [Impact Index Per Article: 3.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/15/2023] Open
Affiliation(s)
- M. Heijblom
- Biomedical Photonic Imaging Group, MIRA Institute for Biomedical Technology and Technical Medicine, University of Twente, P.O. Box 217, 7500 AE Enschede, the Netherlands
- Center for Breast Care, Medisch Spectrum Twente Hospital, P.O. Box 50000, 7500 KA Enschede, the Netherlands
| | - J. M. Klaase
- Center for Breast Care, Medisch Spectrum Twente Hospital, P.O. Box 50000, 7500 KA Enschede, the Netherlands
| | - F. M. van den Engh
- Center for Breast Care, Medisch Spectrum Twente Hospital, P.O. Box 50000, 7500 KA Enschede, the Netherlands
| | - T. G. van Leeuwen
- Biomedical Photonic Imaging Group, MIRA Institute for Biomedical Technology and Technical Medicine, University of Twente, P.O. Box 217, 7500 AE Enschede, the Netherlands
- Biomedical Engineering and Physics, Academic Medical Center, University of Amsterdam, P.O. Box 2270, 1100 DE Amsterdam, the Netherlands
| | - W. Steenbergen
- Biomedical Photonic Imaging Group, MIRA Institute for Biomedical Technology and Technical Medicine, University of Twente, P.O. Box 217, 7500 AE Enschede, the Netherlands
| | - S. Manohar
- Biomedical Photonic Imaging Group, MIRA Institute for Biomedical Technology and Technical Medicine, University of Twente, P.O. Box 217, 7500 AE Enschede, the Netherlands
| |
Collapse
|
7
|
Radiologic and near-infrared/optical spectroscopic imaging: where is the synergy? AJR Am J Roentgenol 2010; 195:321-32. [PMID: 20651186 DOI: 10.2214/ajr.10.5002] [Citation(s) in RCA: 23] [Impact Index Per Article: 1.6] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/12/2022]
Abstract
OBJECTIVE Optical and radiologic imaging are commonly used in preclinical research, and research into combined instruments for human applications is showing promise. The purpose of this article is to outline the fundamental limitations and advantages and to review the available systems. The emerging developments and future potential will be summarized. CONCLUSION Integration of hybrid systems is now routine at the preclinical level and appears in the form of specialized packages in which performance varies considerably. The synergy is commonly focused on using spatial localization from radiographs to provide structural data for spectroscopy; however, applications also exist in which the spectroscopy informs the use of radiologic imaging. Examples of clinical systems under research and development are shown.
Collapse
|
8
|
Sassaroli A, Martelli F, Fantini S. Perturbation theory for the diffusion equation by use of the moments of the generalized temporal point-spread function. III. Frequency-domain and time-domain results. JOURNAL OF THE OPTICAL SOCIETY OF AMERICA. A, OPTICS, IMAGE SCIENCE, AND VISION 2010; 27:1723-42. [PMID: 20596162 PMCID: PMC3429950 DOI: 10.1364/josaa.27.001723] [Citation(s) in RCA: 8] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/20/2023]
Abstract
We study the performance of a previously proposed perturbation theory for the diffusion equation in frequency and time domains as they are known in the field of near infrared spectroscopy and diffuse optical tomography. We have derived approximate formulas for calculating higher order self- and mixed path length moments, up to the fourth order, which can be used in general diffusive media regardless of geometry and initial distribution of the optical properties, for studying the effect of absorbing defects. The method of Padé approximants is used to extend the validity of the theory to a wider range of absorption contrasts between defects and background. By using Monte Carlo simulations, we have tested these formulas in the semi-infinite and slab geometries for the cases of single and multiple absorbing defects having sizes of interest (d=4-10 mm, where d is the diameter of the defect). In frequency domain, the discrepancy between the two methods of calculation (Padé approximants and Monte Carlo simulations) was within 10% for absorption contrasts Deltamu(a)<or=0.2 mm(-1) for alternating current data, and usually to within 1 degrees for Deltamu(a)<or=0.1 mm(-1) for phase data. In time domain, the average discrepancy in the temporal range of interest (a few nanoseconds) was 2%-3% for Deltamu(a)<or=0.06 mm(-1). The proposed method is an effective fast forward problem solver: all the time-domain results presented in this work were obtained with a computational time of less than about 15 s with a Pentium IV 1.66 GHz personal computer.
Collapse
Affiliation(s)
- Angelo Sassaroli
- Department of Biomedical Engineering, Tufts University, 4 Colby Street, Medford, Massachusetts 02155, USA.
| | | | | |
Collapse
|