1
|
Zamboni R, Gauthier-Manuel L, Zaltron A, Lucchetti L, Chauvet M, Sada C. Opto-microfluidic coupling between optical waveguides and tilted microchannels in lithium niobate. OPTICS EXPRESS 2023; 31:28423-28436. [PMID: 37710896 DOI: 10.1364/oe.495406] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Received: 05/16/2023] [Accepted: 07/05/2023] [Indexed: 09/16/2023]
Abstract
This work presents a reconfigurable opto-microfluidic coupling between optical waveguides and tilted microfluidic channels in monolithic lithium niobate crystal. The light path connecting two waveguide arrays located on opposite sides of a microfluidic channel depends on the refractive index between the liquid phase and the hosting crystal. As a result, the optical properties of the flowing fluid, which is pumped into the microfluidic channel on demand, can be exploited to control the light pathways inside the optofluidic device. Proof-of-concept applications are herein presented, including microfluidic optical waveguide switching, optical refractive index sensing, and wavelength demultiplexing.
Collapse
|
2
|
Lialys L, Lialys J, Salandrino A, Ackley BD, Fardad S. Optical trapping of sub-millimeter sized particles and microorganisms. Sci Rep 2023; 13:8615. [PMID: 37244967 DOI: 10.1038/s41598-023-35829-7] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/02/2023] [Accepted: 05/24/2023] [Indexed: 05/29/2023] Open
Abstract
While optical tweezers (OT) are mostly used for confining smaller size particles, the counter-propagating (CP) dual-beam traps have been a versatile method for confining both small and larger size particles including biological specimen. However, CP traps are complex sensitive systems, requiring tedious alignment to achieve perfect symmetry with rather low trapping stiffness values compared to OT. Moreover, due to their relatively weak forces, CP traps are limited in the size of particles they can confine which is about 100 μm. In this paper, a new class of counter-propagating optical tweezers with a broken symmetry is discussed and experimentally demonstrated to trap and manipulate larger than 100 μm particles inside liquid media. Our technique exploits a single Gaussian beam folding back on itself in an asymmetrical fashion forming a CP trap capable of confining small and significantly larger particles (up to 250 μm in diameter) based on optical forces only. Such optical trapping of large-size specimen to the best of our knowledge has not been demonstrated before. The broken symmetry of the trap combined with the retro-reflection of the beam has not only significantly simplified the alignment of the system, but also made it robust to slight misalignments and enhances the trapping stiffness as shown later. Moreover, our proposed trapping method is quite versatile as it allows for trapping and translating of a wide variety of particle sizes and shapes, ranging from one micron up to a few hundred of microns including microorganisms, using very low laser powers and numerical aperture optics. This in turn, permits the integration of a wide range of spectroscopy techniques for imaging and studying the optically trapped specimen. As an example, we will demonstrate how this novel technique enables simultaneous 3D trapping and light-sheet microscopy of C. elegans worms with up to 450 µm length.
Collapse
Affiliation(s)
- Laurynas Lialys
- Department of Electrical Engineering & Computer Science, University of Kansas, Lawrence, 66045, USA
| | - Justinas Lialys
- Department of Electrical Engineering & Computer Science, University of Kansas, Lawrence, 66045, USA
| | - Alessandro Salandrino
- Department of Electrical Engineering & Computer Science, University of Kansas, Lawrence, 66045, USA
- I2S, Institute for Information Sciences, University of Kansas, Lawrence, 66045, USA
| | - Brian D Ackley
- Department of Molecular Biosciences, University of Kansas, Lawrence, 66045, USA
| | - Shima Fardad
- Department of Electrical Engineering & Computer Science, University of Kansas, Lawrence, 66045, USA.
- I2S, Institute for Information Sciences, University of Kansas, Lawrence, 66045, USA.
| |
Collapse
|
3
|
Chen Y, Guo K, Jiang L, Zhu S, Ni Z, Xiang N. Microfluidic deformability cytometry: A review. Talanta 2022; 251:123815. [DOI: 10.1016/j.talanta.2022.123815] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/22/2022] [Revised: 07/23/2022] [Accepted: 08/02/2022] [Indexed: 10/15/2022]
|
4
|
|
5
|
Dawson H, Elias J, Etienne P, Calas-Etienne S. The Rise of the OM-LoC: Opto-Microfluidic Enabled Lab-on-Chip. MICROMACHINES 2021; 12:1467. [PMID: 34945317 PMCID: PMC8706692 DOI: 10.3390/mi12121467] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 11/08/2021] [Revised: 11/22/2021] [Accepted: 11/23/2021] [Indexed: 01/04/2023]
Abstract
The integration of optical circuits with microfluidic lab-on-chip (LoC) devices has resulted in a new era of potential in terms of both sample manipulation and detection at the micro-scale. On-chip optical components increase both control and analytical capabilities while reducing reliance on expensive laboratory photonic equipment that has limited microfluidic development. Notably, in-situ LoC devices for bio-chemical applications such as diagnostics and environmental monitoring could provide great value as low-cost, portable and highly sensitive systems. Multiple challenges remain however due to the complexity involved with combining photonics with micro-fabricated systems. Here, we aim to highlight the progress that optical on-chip systems have made in recent years regarding the main LoC applications: (1) sample manipulation and (2) detection. At the same time, we aim to address the constraints that limit industrial scaling of this technology. Through evaluating various fabrication methods, material choices and novel approaches of optic and fluidic integration, we aim to illustrate how optic-enabled LoC approaches are providing new possibilities for both sample analysis and manipulation.
Collapse
|
6
|
Wu J, Dai B, Li Z, Pan T, Zhang D, Lin F. Emerging optofluidic technologies for biodiagnostic applications. VIEW 2021. [DOI: 10.1002/viw.20200035] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/15/2022] Open
Affiliation(s)
- Jiandong Wu
- Bionic Sensing and Intelligence Center Institute of Biomedical and Health Engineering Shenzhen Institute of Advanced Technology Chinese Academy of Sciences Shenzhen China
| | - Bo Dai
- Engineering Research Center of Optical Instrument and System Ministry of Education Shanghai Key Laboratory of Modern Optical System University of Shanghai for Science and Technology Shanghai China
| | - Zhenqing Li
- Engineering Research Center of Optical Instrument and System Ministry of Education Shanghai Key Laboratory of Modern Optical System University of Shanghai for Science and Technology Shanghai China
| | - Tingrui Pan
- Department of Biomedical Engineering University of California Davis California USA
| | - Dawei Zhang
- Engineering Research Center of Optical Instrument and System Ministry of Education Shanghai Key Laboratory of Modern Optical System University of Shanghai for Science and Technology Shanghai China
| | - Francis Lin
- Department of Physics and Astronomy University of Manitoba Winnipeg Manitoba Canada
| |
Collapse
|
7
|
Yin S, He F, Kubo W, Wang Q, Frame J, Green NG, Fang X. Coherently tunable metalens tweezers for optofluidic particle routing. OPTICS EXPRESS 2020; 28:38949-38959. [PMID: 33379453 DOI: 10.1364/oe.411985] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Received: 10/08/2020] [Accepted: 11/16/2020] [Indexed: 06/12/2023]
Abstract
Nanophotonic particle manipulation exploits unique light shaping capabilities of nanophotonic devices to trap, guide, rotate and propel particles in microfluidic channels. Recent introduction of metalens into microfluidics research demonstrates the new capability of using nanophotonics devices for far-field optical manipulation. In this work we demonstrate, via numerical simulation, the first tunable metalens tweezers that function under dual-beam illumination. The phase profile of the metalens is modulated by controlling the relative strength and phase of the two coherent incident light beams. As a result, the metalens creates a thin sheet of focus inside a microchannel. Changes to the illumination condition allow the focus to be swept across the microchannel, thereby producing a controllable and reconfigurable path for particle transport. Particle routing in a Y-branch junction, for both nano- and microparticles, is evaluated as an example functionality for the tunable metalens tweezers. This work shows that tunable far-field particle manipulation can be achieved using near-field nano-engineering and coherent control, opening a new way for the integration of nanophotonics and microfluidics.
Collapse
|
8
|
Hao Y, Cheng S, Tanaka Y, Hosokawa Y, Yalikun Y, Li M. Mechanical properties of single cells: Measurement methods and applications. Biotechnol Adv 2020; 45:107648. [DOI: 10.1016/j.biotechadv.2020.107648] [Citation(s) in RCA: 19] [Impact Index Per Article: 4.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/12/2020] [Revised: 09/11/2020] [Accepted: 10/12/2020] [Indexed: 12/22/2022]
|
9
|
Vitali V, Nava G, Zanchetta G, Bragheri F, Crespi A, Osellame R, Bellini T, Cristiani I, Minzioni P. Integrated Optofluidic Chip for Oscillatory Microrheology. Sci Rep 2020; 10:5831. [PMID: 32242060 PMCID: PMC7118116 DOI: 10.1038/s41598-020-62628-1] [Citation(s) in RCA: 8] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/24/2019] [Accepted: 03/05/2020] [Indexed: 11/24/2022] Open
Abstract
We propose and demonstrate an on-chip optofluidic device allowing active oscillatory microrheological measurements with sub-μL sample volume, low cost and high flexibility. Thanks to the use of this optofluidic microrheometer it is possible to measure the viscoelastic properties of complex fluids in the frequency range 0.01-10 Hz at different temperatures. The system is based on the optical forces exerted on a microbead by two counterpropagating infrared laser beams. The core elements of the optical part, integrated waveguides and an optical modulator, are fabricated by fs-laser writing on a glass substrate. The system performance is validated by measuring viscoelastic solutions of aqueous worm-like micelles composed by Cetylpyridinium Chloride (CPyCl) and Sodium Salicylate (NaSal).
Collapse
Affiliation(s)
- Valerio Vitali
- University of Pavia, Dept. of Electrical, Computer and Biomedical Engineering, Pavia, 27100, Italy
| | - Giovanni Nava
- University of Milano, Dept. of Medical Biotechnology and Translational Medicine, Milano, 20129, Italy
| | - Giuliano Zanchetta
- University of Milano, Dept. of Medical Biotechnology and Translational Medicine, Milano, 20129, Italy
| | - Francesca Bragheri
- Istituto di Fotonica e Nanotecnologie, Consiglio Nazionale delle Ricerche (IFN-CNR), Milano, 20133, Italy
| | - Andrea Crespi
- Istituto di Fotonica e Nanotecnologie, Consiglio Nazionale delle Ricerche (IFN-CNR), Milano, 20133, Italy
- Dipartimento di Fisica, Politecnico di Milano, Milano, 20133, Italy
| | - Roberto Osellame
- Istituto di Fotonica e Nanotecnologie, Consiglio Nazionale delle Ricerche (IFN-CNR), Milano, 20133, Italy
- Dipartimento di Fisica, Politecnico di Milano, Milano, 20133, Italy
| | - Tommaso Bellini
- University of Milano, Dept. of Medical Biotechnology and Translational Medicine, Milano, 20129, Italy
| | - Ilaria Cristiani
- University of Pavia, Dept. of Electrical, Computer and Biomedical Engineering, Pavia, 27100, Italy
| | - Paolo Minzioni
- University of Pavia, Dept. of Electrical, Computer and Biomedical Engineering, Pavia, 27100, Italy.
| |
Collapse
|
10
|
|
11
|
Li Z, Gao C, Fan S, Zou J, Gu G, Dong M, Song J. Cell Nanomechanics Based on Dielectric Elastomer Actuator Device. NANO-MICRO LETTERS 2019; 11:98. [PMID: 34138039 PMCID: PMC7770812 DOI: 10.1007/s40820-019-0331-8] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 09/16/2019] [Accepted: 10/21/2019] [Indexed: 05/23/2023]
Abstract
As a frontier of biology, mechanobiology plays an important role in tissue and biomedical engineering. It is a common sense that mechanical cues under extracellular microenvironment affect a lot in regulating the behaviors of cells such as proliferation and gene expression, etc. In such an interdisciplinary field, engineering methods like the pneumatic and motor-driven devices have been employed for years. Nevertheless, such techniques usually rely on complex structures, which cost much but not so easy to control. Dielectric elastomer actuators (DEAs) are well known as a kind of soft actuation technology, and their research prospect in biomechanical field is gradually concerned due to their properties just like large deformation (> 100%) and fast response (< 1 ms). In addition, DEAs are usually optically transparent and can be fabricated into small volume, which make them easy to cooperate with regular microscope to realize real-time dynamic imaging of cells. This paper first reviews the basic components, principle, and evaluation of DEAs and then overview some corresponding applications of DEAs for cellular mechanobiology research. We also provide a comparison between DEA-based bioreactors and current custom-built devices and share some opinions about their potential applications in the future according to widely reported results via other methods.
Collapse
Affiliation(s)
- Zhichao Li
- Institute of Nano Biomedicine and Engineering, Department of Instrument Science and Engineering, School of Electronic Information and Electrical Engineering, Shanghai Jiao Tong University, Shanghai, 200240, People's Republic of China
| | - Chao Gao
- Institute of Nano Biomedicine and Engineering, Department of Instrument Science and Engineering, School of Electronic Information and Electrical Engineering, Shanghai Jiao Tong University, Shanghai, 200240, People's Republic of China
| | - Sisi Fan
- Institute of Nano Biomedicine and Engineering, Department of Instrument Science and Engineering, School of Electronic Information and Electrical Engineering, Shanghai Jiao Tong University, Shanghai, 200240, People's Republic of China
| | - Jiang Zou
- Robotics Institute, School of Mechanical Engineering, Shanghai Jiao Tong University, Shanghai, 200240, People's Republic of China
- State Key Laboratory of Mechanical System and Vibration, Shanghai Jiao Tong University, Shanghai, 200240, People's Republic of China
| | - Guoying Gu
- Robotics Institute, School of Mechanical Engineering, Shanghai Jiao Tong University, Shanghai, 200240, People's Republic of China
- State Key Laboratory of Mechanical System and Vibration, Shanghai Jiao Tong University, Shanghai, 200240, People's Republic of China
| | - Mingdong Dong
- Interdisciplinary Nanoscience Center (iNANO), Aarhus University, Aarhus, 8000, Denmark
| | - Jie Song
- Institute of Nano Biomedicine and Engineering, Department of Instrument Science and Engineering, School of Electronic Information and Electrical Engineering, Shanghai Jiao Tong University, Shanghai, 200240, People's Republic of China.
- Shanghai Engineering Research Center of Advanced Dental Technology and Materials, Shanghai Ninth People's Hospital, Shanghai Jiao Tong University, Shanghai, 200240, People's Republic of China.
| |
Collapse
|
12
|
Moon JY, Choi SB, Lee JS, Tanner RI, Lee JS. Numerical simulation of optical control for a soft particle in a microchannel. Phys Rev E 2019; 99:022607. [PMID: 30934346 DOI: 10.1103/physreve.99.022607] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/20/2018] [Indexed: 11/07/2022]
Abstract
Technologies that use optical force to actively control particles in microchannels are a significant area of research interest in various fields. An optical force is generated by the momentum change caused by the refraction and reflection of light, which changes the particle surface as a function of the angle of incidence of light and which in turn feeds back and modifies the force on the particle. Simulating this phenomenon is a complex task. The deformation of a particle, the interaction between the surrounding fluid and the particle, and the reflection and refraction of light should be analyzed simultaneously. Herein, a deformable particle in a microchannel subjected to optical interactions is simulated using the three-dimensional lattice Boltzmann immersed-boundary method. The laser from the optical source is analyzed by dividing it into individual rays. To calculate the optical forces exerted on the particle, the intensity, momentum, and ray direction are calculated. The optical-separator problem with one optical source is analyzed by measuring the distance traveled because of the optical force. The optical-stretcher problem with two optical sources is then studied by analyzing the relation between the intensity of the optical source and particle deformation. This simulation will help the design of sorting and measuring by optical force.
Collapse
Affiliation(s)
- Ji Young Moon
- School of Aerospace, Mechanical and Mechatronic Engineering, The University of Sydney, Sydney, NSW 2006, Australia
| | - Se Bin Choi
- School of Mechanical Engineering, Yonsei University, Seoul, 03722, Republic of Korea
| | - Jung Shin Lee
- School of Mechanical Engineering, Yonsei University, Seoul, 03722, Republic of Korea
| | - Roger I Tanner
- School of Aerospace, Mechanical and Mechatronic Engineering, The University of Sydney, Sydney, NSW 2006, Australia
| | - Joon Sang Lee
- School of Mechanical Engineering, Yonsei University, Seoul, 03722, Republic of Korea
| |
Collapse
|
13
|
Nava G, Yang T, Vitali V, Minzioni P, Cristiani I, Bragheri F, Osellame R, Bethge L, Klussmann S, Paraboschi EM, Asselta R, Bellini T. Newtonian to non-newtonian fluid transition of a model transient network. SOFT MATTER 2018; 14:3288-3295. [PMID: 29691545 DOI: 10.1039/c8sm00373d] [Citation(s) in RCA: 7] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/08/2023]
Abstract
The viscosity of gel-forming fluids is notoriously complex and its study can benefit from new model systems that enable a detailed control of the network features. Here we use a novel and simple microfluidic-based active microrheology approach to study the transition from Newtonian to non-Newtonian behavior in a DNA hydrogel whose structure, connectivity, density of bonds, bond energy and kinetics are strongly temperature dependent and well known. In a temperature range of 15 °C, the system reversibly and continuously transforms from a Newtonian dispersion of low-valence nanocolloids into a strongly shear-thinning fluid, passing through a set of intermediate states where it behaves as a power-law fluid. We demonstrate that the knowledge of network topology and bond free energy enables to quantitatively predict the observed behavior using established rheology models.
Collapse
Affiliation(s)
- Giovanni Nava
- Department of Medical Biotechnology and Translational Medicine, University of Milan, 20129 Milano, Italy.
| | | | | | | | | | | | | | | | | | | | | | | |
Collapse
|
14
|
Paiè P, Zandrini T, Vázquez RM, Osellame R, Bragheri F. Particle Manipulation by Optical Forces in Microfluidic Devices. MICROMACHINES 2018; 9:E200. [PMID: 30424133 PMCID: PMC6187572 DOI: 10.3390/mi9050200] [Citation(s) in RCA: 21] [Impact Index Per Article: 3.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 03/29/2018] [Revised: 04/18/2018] [Accepted: 04/20/2018] [Indexed: 01/09/2023]
Abstract
Since the pioneering work of Ashkin and coworkers, back in 1970, optical manipulation gained an increasing interest among the scientific community. Indeed, the advantages and the possibilities of this technique are unsubtle, allowing for the manipulation of small particles with a broad spectrum of dimensions (nanometers to micrometers size), with no physical contact and without affecting the sample viability. Thus, optical manipulation rapidly found a large set of applications in different fields, such as cell biology, biophysics, and genetics. Moreover, large benefits followed the combination of optical manipulation and microfluidic channels, adding to optical manipulation the advantages of microfluidics, such as a continuous sample replacement and therefore high throughput and automatic sample processing. In this work, we will discuss the state of the art of these optofluidic devices, where optical manipulation is used in combination with microfluidic devices. We will distinguish on the optical method implemented and three main categories will be presented and explored: (i) a single highly focused beam used to manipulate the sample, (ii) one or more diverging beams imping on the sample, or (iii) evanescent wave based manipulation.
Collapse
Affiliation(s)
- Petra Paiè
- Istituto di Fotonica e Nanotecnlogie IFN-CNR, Piazza Leonardo da Vinci 32, Milano 20133, Italy.
| | - Tommaso Zandrini
- Istituto di Fotonica e Nanotecnlogie IFN-CNR, Piazza Leonardo da Vinci 32, Milano 20133, Italy.
- Dipartimento di Chimica, Materiali e Ingegneria Chimica "Giulio Natta", Politecnico di Milano, Piazza Leonardo da Vinci 32, Milano 20133, Italy.
| | - Rebeca Martínez Vázquez
- Istituto di Fotonica e Nanotecnlogie IFN-CNR, Piazza Leonardo da Vinci 32, Milano 20133, Italy.
| | - Roberto Osellame
- Istituto di Fotonica e Nanotecnlogie IFN-CNR, Piazza Leonardo da Vinci 32, Milano 20133, Italy.
- Dipartimento di Fisica, Politecnico di Milano, Piazza Leonardo da Vinci 32, Milano 20133, Italy.
| | - Francesca Bragheri
- Istituto di Fotonica e Nanotecnlogie IFN-CNR, Piazza Leonardo da Vinci 32, Milano 20133, Italy.
| |
Collapse
|
15
|
Xiong W, Xiao G, Han X, Zhou J, Chen X, Luo H. Back-focal-plane displacement detection using side-scattered light in dual-beam fiber-optic traps. OPTICS EXPRESS 2017; 25:9449-9457. [PMID: 28437907 DOI: 10.1364/oe.25.009449] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/07/2023]
Abstract
In optical traps the position of a trapped bead is usually determined by measuring the intensity distribution of the forward-scattered light and the back-scattered light. In this paper we demonstrate that this position can be determined using the side-scattered light. A quadrant photodiode is used to monitor the position of an optically trapped object in a dual-beam fiber-optic trap by measurement of intensity shifts in the back focal plane of the objective that is perpendicular to the propagating beam. An approximated model based on ray optics is presented with numerical results that describe the use of the side-scattered light for position detection. The influences of system parameters, including fiber separations, the numerical apertures (NA), and the radii of microspheres, are discussed in details. We find out that the displacement sensitivity of the detector is null for some critical radii and numerical apertures. In addition, the noises in laser powers are analyzed, and one power difference regime is proposed to weaken the influences.
Collapse
|
16
|
Kamble H, Barton MJ, Jun M, Park S, Nguyen NT. Cell stretching devices as research tools: engineering and biological considerations. LAB ON A CHIP 2016; 16:3193-203. [PMID: 27440436 DOI: 10.1039/c6lc00607h] [Citation(s) in RCA: 50] [Impact Index Per Article: 6.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/04/2023]
Abstract
Cells within the human body are subjected to continuous, cyclic mechanical strain caused by various organ functions, movement, and growth. Cells are well known to have the ability to sense and respond to mechanical stimuli. This process is referred to as mechanotransduction. A better understanding of mechanotransduction is of great interest to clinicians and scientists alike to improve clinical diagnosis and understanding of medical pathology. However, the complexity involved in in vivo biological systems creates a need for better in vitro technologies, which can closely mimic the cells' microenvironment using induced mechanical strain. This technology gap motivates the development of cell stretching devices for better understanding of the cell response to mechanical stimuli. This review focuses on the engineering and biological considerations for the development of such cell stretching devices. The paper discusses different types of stretching concepts, major design consideration and biological aspects of cell stretching and provides a perspective for future development in this research area.
Collapse
Affiliation(s)
- Harshad Kamble
- Queensland Micro- and Nanotechnology Centre, Griffith University, Nathan Campus, 170 Kessels Road, QLD 4111, Australia.
| | - Matthew J Barton
- Menzies Health Institute Queensland, Griffith University, Gold Coast, QLD, Australia
| | - Myeongjun Jun
- School of Mechanical Engineering, Sungkyunkwan University, Suwon, Korea
| | - Sungsu Park
- School of Mechanical Engineering, Sungkyunkwan University, Suwon, Korea
| | - Nam-Trung Nguyen
- Queensland Micro- and Nanotechnology Centre, Griffith University, Nathan Campus, 170 Kessels Road, QLD 4111, Australia.
| |
Collapse
|
17
|
Yang T, Bragheri F, Minzioni P. A Comprehensive Review of Optical Stretcher for Cell Mechanical Characterization at Single-Cell Level. MICROMACHINES 2016; 7:E90. [PMID: 30404265 PMCID: PMC6189960 DOI: 10.3390/mi7050090] [Citation(s) in RCA: 37] [Impact Index Per Article: 4.6] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 03/10/2016] [Revised: 04/14/2016] [Accepted: 04/21/2016] [Indexed: 11/21/2022]
Abstract
This paper presents a comprehensive review of the development of the optical stretcher, a powerful optofluidic device for single cell mechanical study by using optical force induced cell stretching. The different techniques and the different materials for the fabrication of the optical stretcher are first summarized. A short description of the optical-stretching mechanism is then given, highlighting the optical force calculation and the cell optical deformability characterization. Subsequently, the implementations of the optical stretcher in various cell-mechanics studies are shown on different types of cells. Afterwards, two new advancements on optical stretcher applications are also introduced: the active cell sorting based on cell mechanical characterization and the temperature effect on cell stretching measurement from laser-induced heating. Two examples of new functionalities developed with the optical stretcher are also included. Finally, the current major limitation and the future development possibilities are discussed.
Collapse
Affiliation(s)
- Tie Yang
- Department of Electrical, Computer, and Biomedical Engineering, Università di Pavia, Via Ferrata 5A, Pavia 27100, Italy.
| | - Francesca Bragheri
- Institute of Photonics and Nanotechnology, CNR & Department of Physics, Politecnico di Milano, Piazza Leonardo da Vinci 32, Milano 20133, Italy.
| | - Paolo Minzioni
- Department of Electrical, Computer, and Biomedical Engineering, Università di Pavia, Via Ferrata 5A, Pavia 27100, Italy.
| |
Collapse
|
18
|
Chen X, Xiao G, Luo H, Xiong W, Yang K. Dynamics analysis of microsphere in a dual-beam fiber-optic trap with transverse offset. OPTICS EXPRESS 2016; 24:7575-84. [PMID: 27137046 DOI: 10.1364/oe.24.007575] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/14/2023]
Abstract
A comprehensive dynamics analysis of microsphere has been presented in a dual-beam fiber-optic trap with transverse offset. As the offset distance between two counterpropagating beams increases, the motion type of the microsphere starts with capture, then spiral motion, then orbital rotation, and ends with escape. We analyze the transformation process and mechanism of the four motion types based on ray optics approximation. Dynamic simulations show that the existence of critical offset distances at which different motion types transform. The result is an important step toward explaining physical phenomena in a dual-beam fiber-optic trap with transverse offset, and is generally applicable to achieving controllable motions of microspheres in integrated systems, such as microfluidic systems and lab-on-a-chip systems.
Collapse
|
19
|
Yang T, Bragheri F, Nava G, Chiodi I, Mondello C, Osellame R, Berg-Sørensen K, Cristiani I, Minzioni P. A comprehensive strategy for the analysis of acoustic compressibility and optical deformability on single cells. Sci Rep 2016; 6:23946. [PMID: 27040456 PMCID: PMC4819226 DOI: 10.1038/srep23946] [Citation(s) in RCA: 24] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/02/2015] [Accepted: 03/17/2016] [Indexed: 12/17/2022] Open
Abstract
We realized an integrated microfluidic chip that allows measuring both optical deformability and acoustic compressibility on single cells, by optical stretching and acoustophoresis experiments respectively. Additionally, we propose a measurement protocol that allows evaluating the experimental apparatus parameters before performing the cell-characterization experiments, including a non-destructive method to characterize the optical force distribution inside the microchannel. The chip was used to study important cell-mechanics parameters in two human breast cancer cell lines, MCF7 and MDA-MB231. Results indicate that MDA-MB231 has both higher acoustic compressibility and higher optical deformability than MCF7, but statistical analysis shows that optical deformability and acoustic compressibility are not correlated parameters. This result suggests the possibility to use them to analyze the response of different cellular structures. We also demonstrate that it is possible to perform both measurements on a single cell, and that the order of the two experiments does not affect the retrieved values.
Collapse
Affiliation(s)
- Tie Yang
- Department of Electrical, Computer, and Biomedical Engineering, Università di Pavia, Via Ferrata 5A, 27100, Pavia, Italy
| | - Francesca Bragheri
- Institute of Photonics and Nanotechnology, CNR & Department of Physics, Politecnico di Milano, Piazza, Leonardo da Vinci 32, 20133 Milano, Italy
| | - Giovanni Nava
- Department of Biomedical Science and Translational Medicine, Università di Milano, Via F.lli Cervi 91, 20090 Segrate, Italy
| | - Ilaria Chiodi
- Institute of Molecular Genetics (IGM), CNR, Via Abbiategrasso 207, 27100 Pavia, Italy
| | - Chiara Mondello
- Institute of Molecular Genetics (IGM), CNR, Via Abbiategrasso 207, 27100 Pavia, Italy
| | - Roberto Osellame
- Institute of Photonics and Nanotechnology, CNR & Department of Physics, Politecnico di Milano, Piazza, Leonardo da Vinci 32, 20133 Milano, Italy
| | | | - Ilaria Cristiani
- Department of Electrical, Computer, and Biomedical Engineering, Università di Pavia, Via Ferrata 5A, 27100, Pavia, Italy
| | - Paolo Minzioni
- Department of Electrical, Computer, and Biomedical Engineering, Università di Pavia, Via Ferrata 5A, 27100, Pavia, Italy
| |
Collapse
|
20
|
Martinez Vazquez R, Nava G, Veglione M, Yang T, Bragheri F, Minzioni P, Bianchi E, Di Tano M, Chiodi I, Osellame R, Mondello C, Cristiani I. An optofluidic constriction chip for monitoring metastatic potential and drug response of cancer cells. Integr Biol (Camb) 2015; 7:477-84. [PMID: 25804890 DOI: 10.1039/c5ib00023h] [Citation(s) in RCA: 22] [Impact Index Per Article: 2.4] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/21/2022]
Abstract
Cellular mechanical properties constitute good markers to characterize tumor cells, to study cell population heterogeneity and to highlight the effect of drug treatments. In this work, we describe the fabrication and validation of an integrated optofluidic chip capable of analyzing cellular deformability on the basis of the pressure gradient needed to push a cell through a narrow constriction. We demonstrate the ability of the chip to discriminate between tumorigenic and metastatic breast cancer cells (MCF7 and MDA-MB231) and between human melanoma cells with different metastatic potential (A375P and A375MC2). Moreover, we show that this chip allows highlighting the effect of drugs interfering with microtubule organization (paclitaxel, combretastatin A-4 and nocodazole) on cancer cells, which leads to changes in the pressure-gradient required to push cells through the constriction. Our single-cell microfluidic device for mechanical evaluation is compact and easy to use, allowing for an extensive use in different laboratory environments.
Collapse
Affiliation(s)
- R Martinez Vazquez
- Istituto di Fotonica e Nanotecnologie (IFN)-CNR, Piazza Leonardo da Vinci 32, 20133 Milano, Italy
| | | | | | | | | | | | | | | | | | | | | | | |
Collapse
|
21
|
De Coster D, Ottevaere H, Vervaeke M, Van Erps J, Callewaert M, Wuytens P, Simpson SH, Hanna S, De Malsche W, Thienpont H. Mass-manufacturable polymer microfluidic device for dual fiber optical trapping. OPTICS EXPRESS 2015; 23:30991-31009. [PMID: 26698730 DOI: 10.1364/oe.23.030991] [Citation(s) in RCA: 6] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/05/2023]
Abstract
We present a microfluidic chip in Polymethyl methacrylate (PMMA) for optical trapping of particles in an 80µm wide microchannel using two counterpropagating single-mode beams. The trapping fibers are separated from the sample fluid by 70µm thick polymer walls. We calculate the optical forces that act on particles flowing in the microchannel using wave optics in combination with non-sequential ray-tracing and further mathematical processing. Our results are compared with a theoretical model and the Mie theory. We use a novel fabrication process that consists of a premilling step and ultraprecision diamond tooling for the manufacturing of the molds and double-sided hot embossing for replication, resulting in a robust microfluidic chip for optical trapping. In a proof-of-concept demonstration, we show the trapping capabilities of the hot embossed chip by trapping spherical beads with a diameter of 6µm, 8µm and 10µm and use the power spectrum analysis of the trapped particle displacements to characterize the trap strength.
Collapse
|
22
|
Yang T, Nava G, Minzioni P, Veglione M, Bragheri F, Lelii FD, Vazquez RM, Osellame R, Cristiani I. Investigation of temperature effect on cell mechanics by optofluidic microchips. BIOMEDICAL OPTICS EXPRESS 2015; 6:2991-2996. [PMID: 26309762 PMCID: PMC4541526 DOI: 10.1364/boe.6.002991] [Citation(s) in RCA: 8] [Impact Index Per Article: 0.9] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 03/20/2015] [Revised: 07/06/2015] [Accepted: 07/06/2015] [Indexed: 06/04/2023]
Abstract
Here we present the results of a study concerning the effect of temperature on cell mechanical properties. Two different optofluidic microchips with external temperature control are used to investigate the temperature-induced changes of highly metastatic human melanoma cells (A375MC2) in the range of ~0 - 35 °C. By means of an integrated optical stretcher, we observe that cells' optical deformability is strongly enhanced by increasing cell and buffer-fluid temperature. This finding is supported by the results obtained from a second device, which probes the cells' ability to be squeezed through a constriction. Measured data demonstrate a marked dependence of cell mechanical properties on temperature, thus highlighting the importance of including a proper temperature-control system in the experimental apparatus.
Collapse
Affiliation(s)
- Tie Yang
- Dip. Ingegneria Industriale e dell’Informazione, Università di Pavia, Via Ferrata 5A, 27100 Pavia, Italy
| | - Giovanni Nava
- Dip. Ingegneria Industriale e dell’Informazione, Università di Pavia, Via Ferrata 5A, 27100 Pavia, Italy
- Dip. Biotecnologie Mediche e Medicina Traslazionale, Università di Milano,Via F.lli Cervi 91, 20090 Segrate, Italy
| | - Paolo Minzioni
- Dip. Ingegneria Industriale e dell’Informazione, Università di Pavia, Via Ferrata 5A, 27100 Pavia, Italy
| | - Manuela Veglione
- Istituto di Genetica Molecolare (IGM) – CNR, Via Abbiategrasso 207, 27100 Pavia, Italy
| | - Francesca Bragheri
- Istituto di Fotonica e Nanotecnologie (IFN)-CNR,Piazza Leonardo da Vinci 32, 20133 Milano, Italy
| | - Francesca Demetra Lelii
- Dip. Ingegneria Industriale e dell’Informazione, Università di Pavia, Via Ferrata 5A, 27100 Pavia, Italy
| | - Rebeca Martinez Vazquez
- Istituto di Fotonica e Nanotecnologie (IFN)-CNR,Piazza Leonardo da Vinci 32, 20133 Milano, Italy
| | - Roberto Osellame
- Istituto di Fotonica e Nanotecnologie (IFN)-CNR,Piazza Leonardo da Vinci 32, 20133 Milano, Italy
| | - Ilaria Cristiani
- Dip. Ingegneria Industriale e dell’Informazione, Università di Pavia, Via Ferrata 5A, 27100 Pavia, Italy
| |
Collapse
|
23
|
Faigle C, Lautenschläger F, Whyte G, Homewood P, Martín-Badosa E, Guck J. A monolithic glass chip for active single-cell sorting based on mechanical phenotyping. LAB ON A CHIP 2015; 15:1267-1275. [PMID: 25537986 DOI: 10.1039/c4lc01196a] [Citation(s) in RCA: 20] [Impact Index Per Article: 2.2] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/04/2023]
Abstract
The mechanical properties of biological cells have long been considered as inherent markers of biological function and disease. However, the screening and active sorting of heterogeneous populations based on serial single-cell mechanical measurements has not been demonstrated. Here we present a novel monolithic glass chip for combined fluorescence detection and mechanical phenotyping using an optical stretcher. A new design and manufacturing process, involving the bonding of two asymmetrically etched glass plates, combines exact optical fiber alignment, low laser damage threshold and high imaging quality with the possibility of several microfluidic inlet and outlet channels. We show the utility of such a custom-built optical stretcher glass chip by measuring and sorting single cells in a heterogeneous population based on their different mechanical properties and verify sorting accuracy by simultaneous fluorescence detection. This offers new possibilities of exact characterization and sorting of small populations based on rheological properties for biological and biomedical applications.
Collapse
Affiliation(s)
- Christoph Faigle
- Biotechnology Center, Technische Universität Dresden, Dresden, Germany.
| | | | | | | | | | | |
Collapse
|
24
|
Gu Y, Bragheri F, Valentino G, Morris K, Bellini N, Osellame R. Ferrofluid-based optofluidic switch using femtosecond laser-micromachined waveguides. APPLIED OPTICS 2015; 54:1420-1425. [PMID: 25968208 DOI: 10.1364/ao.54.001420] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Received: 10/16/2014] [Accepted: 01/08/2015] [Indexed: 06/04/2023]
Abstract
We present a portable optofluidic switch using a ferrofluid plug in a commercially produced microfluidic chip with waveguides added via femtosecond laser micromachining (FLM). FLM enabled the one-step fabrication of highly reproducible, perfectly aligned integrated waveguides orthogonally crossing an existing microfluidic channel. In the "ON" state for each output, the ferrofluid plug is outside the intersection and input light arrives at the output with relatively small loss. In the "OFF" state, the plug is inside the intersection and the input light is absorbed. The same plug is used to turn ON and OFF several parallel waveguides with contrast ratios of 22 dB or better. In addition, the plug is driven periodically using an electromagnet combined with a permanent magnet for frequency-dependent characterization. Photodiode data show high contrast up to 50 Hz and linear frequency response up to 1 KHz.
Collapse
|
25
|
Dynamic operation of optical fibres beyond the single-mode regime facilitates the orientation of biological cells. Nat Commun 2014; 5:5481. [PMID: 25410595 PMCID: PMC4263128 DOI: 10.1038/ncomms6481] [Citation(s) in RCA: 35] [Impact Index Per Article: 3.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/05/2014] [Accepted: 10/06/2014] [Indexed: 01/27/2023] Open
Abstract
The classical purpose of optical fibres is delivery of either optical power, as for welding, or temporal information, as for telecommunication. Maximum performance in both cases is provided by the use of single-mode optical fibres. However, transmitting spatial information, which necessitates higher-order modes, is difficult because their dispersion relation leads to dephasing and a deterioration of the intensity distribution with propagation distance. Here we consciously exploit the fundamental cause of the beam deterioration—the dispersion relation of the underlying vectorial electromagnetic modes—by their selective excitation using adaptive optics. This allows us to produce output beams of high modal purity, which are well defined in three dimensions. The output beam distribution is even robust against significant bending of the fibre. The utility of this approach is exemplified by the controlled rotational manipulation of live cells in a dual-beam fibre-optical trap integrated into a modular lab-on-chip system. Transmitting spatial information through optical fibres is difficult because scalar high-order modes deteriorate. Here, the authors counter deterioration using adaptive optics to excite vectorial modes, achieving high-quality beams robust against fibre bending and use those to rotate cells in a laser trap.
Collapse
|
26
|
Paiè P, Bragheri F, Vazquez RM, Osellame R. Straightforward 3D hydrodynamic focusing in femtosecond laser fabricated microfluidic channels. LAB ON A CHIP 2014; 14:1826-33. [PMID: 24740611 DOI: 10.1039/c4lc00133h] [Citation(s) in RCA: 21] [Impact Index Per Article: 2.1] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/11/2023]
Abstract
We report on the use of femtosecond laser irradiation followed by chemical etching as a microfabrication tool for innovative microfluidic networks that implement hydrodynamic focusing. The capability of our microfabrication technology to interconnect microchannels in three dimensions was exploited to demonstrate 2D hydrodynamic focusing, either in the horizontal or in the vertical plane, and full 3D hydrodynamic focusing. In all cases only two inlets were required, one for the sample and one for the sheath flows. Fluidic characterization of all devices was provided. In addition, taking advantage of the possibility to write optical waveguides using the same technology, a monolithic cell counter based on 3D hydrodynamic focusing and integrated optical detection was validated. Counting rates up to 5000 cells s(-1) were achieved in this very compact device, where focusing and counting operations were implemented in less than 1 mm(3). Integration of this hydrodynamic focusing module into several devices fabricated by the same technology as optical cell stretchers and cell sorters is envisaged.
Collapse
Affiliation(s)
- Petra Paiè
- Dipartimento di Fisica, Politecnico di Milano, Piazza Leonardo da Vinci 32, 20133 Milano, Italy.
| | | | | | | |
Collapse
|
27
|
Kolb T, Albert S, Haug M, Whyte G. Dynamically reconfigurable fibre optical spanner. LAB ON A CHIP 2014; 14:1186-90. [PMID: 24493284 DOI: 10.1039/c3lc51277k] [Citation(s) in RCA: 15] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/14/2023]
Abstract
In this paper we describe a pneumatically actuated fibre-optic spanner integrated into a microfluidic Lab-on-a-Chip device for the controlled trapping and rotation of living cells. The dynamic nature of the system allows interactive control over the rotation speed with the same optical power. The use of a multi-layer device makes it possible to rotate a cell both in the imaging plane and also in a perpendicular plane allowing tomographic imaging of the trapped living cell. The integrated device allows easy operation and by combining it with high-resolution confocal microscopy we show for the first time that the pattern of rotation can give information regarding the sub-cellular composition of a rotated cell.
Collapse
Affiliation(s)
- Thorsten Kolb
- Biophysics Group, Department of Physics, Friedrich-Alexander Universität Erlangen-Nürnberg, Henkestrasse 91, 91052 Erlangen, Germany.
| | | | | | | |
Collapse
|