1
|
Zhou W, Villa U, Anastasio MA. Ideal Observer Computation by Use of Markov-Chain Monte Carlo With Generative Adversarial Networks. IEEE TRANSACTIONS ON MEDICAL IMAGING 2023; 42:3715-3724. [PMID: 37578916 PMCID: PMC10769588 DOI: 10.1109/tmi.2023.3304907] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 08/16/2023]
Abstract
Medical imaging systems are often evaluated and optimized via objective, or task-specific, measures of image quality (IQ) that quantify the performance of an observer on a specific clinically-relevant task. The performance of the Bayesian Ideal Observer (IO) sets an upper limit among all observers, numerical or human, and has been advocated for use as a figure-of-merit (FOM) for evaluating and optimizing medical imaging systems. However, the IO test statistic corresponds to the likelihood ratio that is intractable to compute in the majority of cases. A sampling-based method that employs Markov-chain Monte Carlo (MCMC) techniques was previously proposed to estimate the IO performance. However, current applications of MCMC methods for IO approximation have been limited to a small number of situations where the considered distribution of to-be-imaged objects can be described by a relatively simple stochastic object model (SOM). As such, there remains an important need to extend the domain of applicability of MCMC methods to address a large variety of scenarios where IO-based assessments are needed but the associated SOMs have not been available. In this study, a novel MCMC method that employs a generative adversarial network (GAN)-based SOM, referred to as MCMC-GAN, is described and evaluated. The MCMC-GAN method was quantitatively validated by use of test-cases for which reference solutions were available. The results demonstrate that the MCMC-GAN method can extend the domain of applicability of MCMC methods for conducting IO analyses of medical imaging systems.
Collapse
|
2
|
O’Neill AG, Valdez EL, Lingala SG, Pineda AR. Modeling human observer detection in undersampled magnetic resonance imaging reconstruction with total variation and wavelet sparsity regularization. J Med Imaging (Bellingham) 2023; 10:015502. [PMID: 36852415 PMCID: PMC9961227 DOI: 10.1117/1.jmi.10.1.015502] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/14/2022] [Accepted: 02/06/2023] [Indexed: 02/27/2023] Open
Abstract
Purpose Task-based assessment of image quality in undersampled magnetic resonance imaging provides a way of evaluating the impact of regularization on task performance. In this work, we evaluated the effect of total variation (TV) and wavelet regularization on human detection of signals with a varying background and validated a model observer in predicting human performance. Approach Human observer studies used two-alternative forced choice (2-AFC) trials with a small signal known exactly task but with varying backgrounds for fluid-attenuated inversion recovery images reconstructed from undersampled multi-coil data. We used a 3.48 undersampling factor with TV and a wavelet sparsity constraints. The sparse difference-of-Gaussians (S-DOG) observer with internal noise was used to model human observer detection. The internal noise for the S-DOG was chosen to match the average percent correct (PC) in 2-AFC studies for four observers using no regularization. That S-DOG model was used to predict the PC of human observers for a range of regularization parameters. Results We observed a trend that the human observer detection performance remained fairly constant for a broad range of values in the regularization parameter before decreasing at large values. A similar result was found for the normalized ensemble root mean squared error. Without changing the internal noise, the model observer tracked the performance of the human observers as the regularization was increased but overestimated the PC for large amounts of regularization for TV and wavelet sparsity, as well as the combination of both parameters. Conclusions For the task we studied, the S-DOG observer was able to reasonably predict human performance with both TV and wavelet sparsity regularizers over a broad range of regularization parameters. We observed a trend that task performance remained fairly constant for a range of regularization parameters before decreasing for large amounts of regularization.
Collapse
Affiliation(s)
- Alexandra G. O’Neill
- Manhattan College, Department of Mathematics, New York City, New York, United States
| | - Emely L. Valdez
- Manhattan College, Department of Mathematics, New York City, New York, United States
| | - Sajan Goud Lingala
- University of Iowa, Roy J. Carver Department of Biomedical Engineering, Iowa City, Iowa, United States
| | - Angel R. Pineda
- Manhattan College, Department of Mathematics, New York City, New York, United States
| |
Collapse
|
3
|
Rahman MA, Yu Z, Jha AK. Ideal-Observer Computation with anthropomorphic phantoms using Markov chain Monte Carlo. PROCEEDINGS. IEEE INTERNATIONAL SYMPOSIUM ON BIOMEDICAL IMAGING 2022; 2022:10.1109/isbi52829.2022.9761579. [PMID: 36388622 PMCID: PMC9648621 DOI: 10.1109/isbi52829.2022.9761579] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 04/28/2023]
Abstract
In medical imaging, it is widely recognized that image quality should be objectively evaluated based on performance in clinical tasks. To evaluate performance in signal-detection tasks, the ideal observer (IO) is optimal but also challenging to compute in clinically realistic settings. Markov Chain Monte Carlo (MCMC)-based strategies have demonstrated the ability to compute the IO using pre-computed projections of an anatomical database. To evaluate image quality in clinically realistic scenarios, the observer performance should be measured for a realistic patient distribution. This implies that the anatomical database should also be derived from a realistic population. In this manuscript, we propose to advance the MCMC-based approach towards achieving these goals. We then use the proposed approach to study the effect of anatomical database size on IO computation for the task of detecting perfusion defects in simulated myocardial perfusion SPECT images. Our preliminary results provide evidence that the size of the anatomical database affects the computation of the IO.
Collapse
Affiliation(s)
- Md Ashequr Rahman
- Department of Biomedical Engineering, Washington University in St. Louis, St. Louis, MO, USA
- Mallinckrodt Institute of Radiology, Washington University in St. Louis, St. Louis, MO, USA
| | - Zitong Yu
- Department of Biomedical Engineering, Washington University in St. Louis, St. Louis, MO, USA
- Mallinckrodt Institute of Radiology, Washington University in St. Louis, St. Louis, MO, USA
| | - Abhinav K Jha
- Department of Biomedical Engineering, Washington University in St. Louis, St. Louis, MO, USA
- Mallinckrodt Institute of Radiology, Washington University in St. Louis, St. Louis, MO, USA
| |
Collapse
|
4
|
Jha AK, Myers KJ, Obuchowski NA, Liu Z, Rahman MA, Saboury B, Rahmim A, Siegel BA. Objective Task-Based Evaluation of Artificial Intelligence-Based Medical Imaging Methods:: Framework, Strategies, and Role of the Physician. PET Clin 2021; 16:493-511. [PMID: 34537127 DOI: 10.1016/j.cpet.2021.06.013] [Citation(s) in RCA: 19] [Impact Index Per Article: 6.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/23/2022]
Abstract
Artificial intelligence-based methods are showing promise in medical imaging applications. There is substantial interest in clinical translation of these methods, requiring that they be evaluated rigorously. We lay out a framework for objective task-based evaluation of artificial intelligence methods. We provide a list of available tools to conduct this evaluation. We outline the important role of physicians in conducting these evaluation studies. The examples in this article are proposed in the context of PET scans with a focus on evaluating neural network-based methods. However, the framework is also applicable to evaluate other medical imaging modalities and other types of artificial intelligence methods.
Collapse
Affiliation(s)
- Abhinav K Jha
- Department of Biomedical Engineering, Mallinckrodt Institute of Radioly, Alvin J. Siteman Cancer Center, Washington University in St. Louis, 510 S Kingshighway Boulevard, St Louis, MO 63110, USA.
| | - Kyle J Myers
- Division of Imaging, Diagnostics, and Software Reliability, Office of Science and Engineering Laboratories, Center for Devices and Radiological Health, Food and Drug Administration (FDA), Silver Spring, MD, USA
| | | | - Ziping Liu
- Department of Biomedical Engineering, Washington University in St. Louis, 1 Brookings Drive, St Louis, MO 63130, USA
| | - Md Ashequr Rahman
- Department of Biomedical Engineering, Washington University in St. Louis, 1 Brookings Drive, St Louis, MO 63130, USA
| | - Babak Saboury
- Department of Radiology and Imaging Sciences, Clinical Center, National Institutes of Health, 9000 Rockville Pike, Bethesda, MD 20892, USA
| | - Arman Rahmim
- Department of Radiology, Department of Physics, University of British Columbia, BC Cancer, BC Cancer Research Institute, 675 West 10th Avenue, Office 6-112, Vancouver, British Columbia V5Z 1L3, Canada
| | - Barry A Siegel
- Division of Nuclear Medicine, Mallinckrodt Institute of Radiology, Alvin J. Siteman Cancer Center, Washington University School of Medicine, 510 S Kingshighway Boulevard #956, St Louis, MO 63110, USA
| |
Collapse
|
5
|
Rahman MA, Jha AK. Task-based assessment of binned and list-mode SPECT systems. PROCEEDINGS OF SPIE--THE INTERNATIONAL SOCIETY FOR OPTICAL ENGINEERING 2021; 11599:1159904. [PMID: 34345113 PMCID: PMC8325874 DOI: 10.1117/12.2582266] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 01/02/2023]
Abstract
In SPECT, list-mode (LM) format allows storing data at higher precision compared to binned data. There is significant interest in investigating whether this higher precision translates to improved performance on clinical tasks. Towards this goal, in this study, we quantitatively investigated whether processing data in LM format, and in particular, the energy attribute of the detected photon, provides improved performance on the task of absolute quantification of region-of-interest (ROI) uptake in comparison to processing the data in binned format. We conducted this evaluation study using a DaTscan brain SPECT acquisition protocol, conducted in the context of imaging patients with Parkinson's disease. This study was conducted with a synthetic phantom. A signal-known exactly/background-known-statistically (SKE/BKS) setup was considered. An ordered-subset expectation-maximization algorithm was used to reconstruct images from data acquired in LM format, including the scatter-window data, and including the energy attribute of each LM event. Using a realistic 2-D SPECT system simulation, quantification tasks were performed on the reconstructed images. The results demonstrated improved quantification performance when LM data was used compared to binning the attributes in all the conducted evaluation studies. Overall, we observed that LM data, including the energy attribute, yielded improved performance on absolute quantification tasks compared to binned data.
Collapse
Affiliation(s)
- Md Ashequr Rahman
- Department of Biomedical Engineering, Washington University in St. Louis, St. Louis, MO, USA
- Mallinckrodt Institute of Radiology, Washington University in St. Louis, St. Louis, MO, USA
| | - Abhinav K. Jha
- Department of Biomedical Engineering, Washington University in St. Louis, St. Louis, MO, USA
- Mallinckrodt Institute of Radiology, Washington University in St. Louis, St. Louis, MO, USA
| |
Collapse
|
6
|
Jha AK, Zhu Y, Arridge S, Wong DF, Rahmim A. Incorporating reflection boundary conditions in the Neumann series radiative transport equation: application to photon propagation and reconstruction in diffuse optical imaging. BIOMEDICAL OPTICS EXPRESS 2018; 9:1389-1407. [PMID: 29675291 PMCID: PMC5905895 DOI: 10.1364/boe.9.001389] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 09/28/2017] [Revised: 11/28/2017] [Accepted: 12/26/2017] [Indexed: 05/11/2023]
Abstract
We propose a formalism to incorporate boundary conditions in a Neumann-series-based radiative transport equation. The formalism accurately models the reflection of photons at the tissue-external medium interface using Fresnel's equations. The formalism was used to develop a gradient descent-based image reconstruction technique. The proposed methods were implemented for 3D diffuse optical imaging. In computational studies, it was observed that the average root-mean-square error (RMSE) for the output images and the estimated absorption coefficients reduced by 38% and 84%, respectively, when the reflection boundary conditions were incorporated. These results demonstrate the importance of incorporating boundary conditions that model the reflection of photons at the tissue-external medium interface.
Collapse
Affiliation(s)
- Abhinav K. Jha
- Department of Radiology and Radiological Sciences, Johns Hopkins University, Baltimore, MD,
USA
- Department of Biomedical Engineering, Washington University in St. Louis, St. Louis, MO, USA
- Mallinckrodt Institute of Radiology, Washington University in St. Louis, St. Louis, MO, USA
| | - Yansong Zhu
- Department of Radiology and Radiological Sciences, Johns Hopkins University, Baltimore, MD,
USA
- Department of Electrical and Computer Engineering, Johns Hopkins University, Baltimore, MD, USA
| | - Simon Arridge
- Department of Computer Science, University College London, Gower Street, London WC1E 6BT, UK
| | - Dean F. Wong
- Department of Radiology and Radiological Sciences, Johns Hopkins University, Baltimore, MD,
USA
- Department of Neuroscience, Johns Hopkins University, Baltimore, MD, USA
- Department of Psychiatry and Behavioral Sciences, Johns Hopkins University, Baltimore, MD, USA
- Department of Neurology, Johns Hopkins University, Baltimore, MD, USA
| | - Arman Rahmim
- Department of Radiology and Radiological Sciences, Johns Hopkins University, Baltimore, MD,
USA
- Department of Electrical and Computer Engineering, Johns Hopkins University, Baltimore, MD, USA
| |
Collapse
|
7
|
Li X, Jha AK, Ghaly M, Elshahaby FEA, Links JM, Frey EC. Use of Sub-Ensembles and Multi-Template Observers to Evaluate Detection Task Performance for Data That are Not Multivariate Normal. IEEE TRANSACTIONS ON MEDICAL IMAGING 2017; 36:917-929. [PMID: 28026757 PMCID: PMC5496770 DOI: 10.1109/tmi.2016.2643684] [Citation(s) in RCA: 11] [Impact Index Per Article: 1.6] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/14/2023]
Abstract
The Hotelling Observer (HO) is widely used to evaluate image quality in medical imaging. However, applying it to data that are not multivariate-normally (MVN) distributed is not optimal. In this paper, we apply two multi-template linear observer strategies to handle such data. First, the entire data ensemble is divided into sub-ensembles that are exactly or approximately MVN and homoscedastic. Next, a different linear observer template is estimated for and applied to each sub-ensemble. The first multi-template strategy, adapted from previous work, applies the HO to each sub-ensemble, calculates the area under the receiver operating characteristics curve (AUC) for each sub-ensemble, and averages the AUCs from all the sub-ensembles. The second strategy applies the Linear Discriminant (LD) to estimate test statistics for each sub-ensemble and calculates a single global AUC using the pooled test statistics from all the sub-ensembles. We show that this second strategy produces the maximum AUC when only shifting of the HO test statistics is allowed. We compared these strategies to the use of a single HO template for the entire data ensemble by applying them to the non-MVN data obtained from reconstructed images of a realistic simulated population of myocardial perfusion SPECT studies with the goal of optimizing the reconstruction parameters. Of the strategies investigated, the multi-template LD strategy yielded the highest AUC for any given set of reconstruction parameters. The optimal reconstruction parameters obtained by the two multi-template strategies were comparable and produced higher AUCs for each sub-ensemble than the single-template HO strategy.
Collapse
|
8
|
Jha AK, Zhu Y, Wong DF, Rahmim A. A radiative transfer equation-based image-reconstruction method incorporating boundary conditions for diffuse optical imaging. PROCEEDINGS OF SPIE--THE INTERNATIONAL SOCIETY FOR OPTICAL ENGINEERING 2017; 10137. [PMID: 28736472 DOI: 10.1117/12.2255802] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 12/23/2022]
Abstract
Developing reconstruction methods for diffuse optical imaging requires accurate modeling of photon propagation, including boundary conditions arising due to refractive index mismatch as photons propagate from the tissue to air. For this purpose, we developed an analytical Neumann-series radiative transport equation (RTE)-based approach. Each Neumann series term models different scattering, absorption, and boundary-reflection events. The reflection is modeled using the Fresnel equation. We use this approach to design a gradient-descent-based analytical reconstruction algorithm for a three-dimensional (3D) setup of a diffuse optical imaging (DOI) system. The algorithm was implemented for a three-dimensional DOI system consisting of a laser source, cuboidal scattering medium (refractive index > 1), and a pixelated detector at one cuboid face. In simulation experiments, the refractive index of the scattering medium was varied to test the robustness of the reconstruction algorithm over a wide range of refractive index mismatches. The experiments were repeated over multiple noise realizations. Results showed that by using the proposed algorithm, the photon propagation was modeled more accurately. These results demonstrated the importance of modeling boundary conditions in the photon-propagation model.
Collapse
Affiliation(s)
- Abhinav K Jha
- Department of Radiology, Johns Hopkins University, Baltimore, MD, USA
| | - Yansong Zhu
- Department of Electrical and Computer Engineering, Baltimore, MD, USA
| | - Dean F Wong
- Department of Radiology, Johns Hopkins University, Baltimore, MD, USA
| | - Arman Rahmim
- Department of Radiology, Johns Hopkins University, Baltimore, MD, USA.,Department of Electrical and Computer Engineering, Baltimore, MD, USA
| |
Collapse
|
9
|
Zhu Y, Jha AK, Dreyer JK, Le HND, Kang JU, Roland PE, Wong DF, Rahmim A. A three-step reconstruction method for fluorescence molecular tomography based on compressive sensing. PROCEEDINGS OF SPIE--THE INTERNATIONAL SOCIETY FOR OPTICAL ENGINEERING 2017; 10059. [PMID: 28596634 DOI: 10.1117/12.2252664] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 12/24/2022]
Abstract
Fluorescence molecular tomography (FMT) is a promising tool for real time in vivo quantification of neurotransmission (NT) as we pursue in our BRAIN initiative effort. However, the acquired image data are noisy and the reconstruction problem is ill-posed. Further, while spatial sparsity of the NT effects could be exploited, traditional compressive-sensing methods cannot be directly applied as the system matrix in FMT is highly coherent. To overcome these issues, we propose and assess a three-step reconstruction method. First, truncated singular value decomposition is applied on the data to reduce matrix coherence. The resultant image data are input to a homotopy-based reconstruction strategy that exploits sparsity via ℓ1 regularization. The reconstructed image is then input to a maximum-likelihood expectation maximization (MLEM) algorithm that retains the sparseness of the input estimate and improves upon the quantitation by accurate Poisson noise modeling. The proposed reconstruction method was evaluated in a three-dimensional simulated setup with fluorescent sources in a cuboidal scattering medium with optical properties simulating human brain cortex (reduced scattering coefficient: 9.2 cm-1, absorption coefficient: 0.1 cm-1) and tomographic measurements made using pixelated detectors. In different experiments, fluorescent sources of varying size and intensity were simulated. The proposed reconstruction method provided accurate estimates of the fluorescent source intensity, with a 20% lower root mean square error on average compared to the pure-homotopy method for all considered source intensities and sizes. Further, compared with conventional ℓ2 regularized algorithm, overall, the proposed method reconstructed substantially more accurate fluorescence distribution. The proposed method shows considerable promise and will be tested using more realistic simulations and experimental setups.
Collapse
Affiliation(s)
- Yansong Zhu
- Department of Electrical and Computer Engineering, Johns Hopkins University, Baltimore, USA
| | - Abhinav K Jha
- Department of Radiology, Johns Hopkins University, Baltimore, USA
| | - Jakob K Dreyer
- Department of Neuroscience and Pharmacology, University of Copenhagen, Copenhagen, Denmark
| | - Hanh N D Le
- Department of Electrical and Computer Engineering, Johns Hopkins University, Baltimore, USA
| | - Jin U Kang
- Department of Electrical and Computer Engineering, Johns Hopkins University, Baltimore, USA
| | - Per E Roland
- Department of Neuroscience and Pharmacology, University of Copenhagen, Copenhagen, Denmark
| | - Dean F Wong
- Department of Radiology, Johns Hopkins University, Baltimore, USA
| | - Arman Rahmim
- Department of Electrical and Computer Engineering, Johns Hopkins University, Baltimore, USA.,Department of Radiology, Johns Hopkins University, Baltimore, USA
| |
Collapse
|
10
|
Caucci L, Myers KJ, Barrett HH. Radiance and photon noise: imaging in geometrical optics, physical optics, quantum optics and radiology. OPTICAL ENGINEERING (REDONDO BEACH, CALIF.) 2016; 55:10.1117/1.oe.55.1.013102. [PMID: 32139948 PMCID: PMC7058161 DOI: 10.1117/1.oe.55.1.013102] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/10/2023]
Abstract
The statistics of detector outputs produced by an imaging system are derived from basic radiometric concepts and definitions. We show that a fundamental way of describing a photon-limited imaging system is in terms of a Poisson random process in spatial, angular, and wavelength variables. We begin the paper by recalling the concept of radiance in geometrical optics, radiology, physical optics, and quantum optics. The propagation and conservation laws for radiance in each of these domains are reviewed. Building upon these concepts, we distinguish four categories of imaging detectors that all respond in some way to the incident radiance, including the new category of photon-processing detectors (capable of measuring radiance on a photon-by-photon basis). This allows us to rigorously show how the concept of radiance is related to the statistical properties of detector outputs and to the information content of a single detected photon. A Monte-Carlo technique, which is derived from the Boltzmann transport equation, is presented as a way to estimate probability density functions to be used in reconstruction from photon-processing data.
Collapse
Affiliation(s)
- Luca Caucci
- The University of Arizona, Center for Gamma-Ray Imaging, Department of Medical Imaging, 1609 North Warren Avenue, Tucson, Arizona 85724, United States
| | - Kyle J. Myers
- U.S. Food and Drug Administration, Center for Devices and Radiological Health, Division of Imaging and Applied Mathematics, 10903 New Hampshire Avenue, Silver Spring, Maryland 20993, United States
| | - Harrison H. Barrett
- The University of Arizona, Center for Gamma-Ray Imaging, Department of Medical Imaging, 1609 North Warren Avenue, Tucson, Arizona 85724, United States
- University of Arizona, College of Optical Sciences, 1630 East University Boulevard, Tucson, Arizona 85719, United States
| |
Collapse
|
11
|
Barrett HH, Myers KJ, Caucci L. RADIANCE AND PHOTON NOISE: Imaging in geometrical optics, physical optics, quantum optics and radiology. PROCEEDINGS OF SPIE--THE INTERNATIONAL SOCIETY FOR OPTICAL ENGINEERING 2014; 9193. [PMID: 27478293 DOI: 10.1117/12.2066715] [Citation(s) in RCA: 8] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 12/25/2022]
Abstract
A fundamental way of describing a photon-limited imaging system is in terms of a Poisson random process in spatial, angular and wavelength variables. The mean of this random process is the spectral radiance. The principle of conservation of radiance then allows a full characterization of the noise in the image (conditional on viewing a specified object). To elucidate these connections, we first review the definitions and basic properties of radiance as defined in terms of geometrical optics, radiology, physical optics and quantum optics. The propagation and conservation laws for radiance in each of these domains are reviewed. Then we distinguish four categories of imaging detectors that all respond in some way to the incident radiance, including the new category of photon-processing detectors. The relation between the radiance and the statistical properties of the detector output is discussed and related to task-based measures of image quality and the information content of a single detected photon.
Collapse
Affiliation(s)
- Harrison H Barrett
- College of Optical Sciences, University of Arizona, Tucson AZ 85721; Center for Gamma-Ray Imaging, Dept. of Medical Imaging, Tucson AZ 85724
| | - Kyle J Myers
- Div. of Imaging and Applied Mathematics, Center for Devices and Radiological Health, Food and Drug Administration, Silver Spring, MD 20993
| | - Luca Caucci
- Center for Gamma-Ray Imaging, Dept. of Medical Imaging, Tucson AZ 85724
| |
Collapse
|