1
|
Varkhede N, Bommana R, Schöneich C, Forrest ML. Proteolysis and Oxidation of Therapeutic Proteins After Intradermal or Subcutaneous Administration. J Pharm Sci 2020; 109:191-205. [PMID: 31408633 PMCID: PMC6937400 DOI: 10.1016/j.xphs.2019.08.005] [Citation(s) in RCA: 22] [Impact Index Per Article: 5.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/25/2019] [Revised: 08/05/2019] [Accepted: 08/06/2019] [Indexed: 12/12/2022]
Abstract
The intradermal (ID) and subcutaneous (SC) routes are commonly used for therapeutic proteins (TPs) and vaccines; however, the bioavailability of TPs is typically less than small molecule drugs given via the same routes. Proteolytic enzymes in the dermal, SC, and lymphatic tissues may be responsible for the loss of TPs. In addition, the TPs may be exposed to reactive oxygen species generated in the SC tissue and the lymphatic system in response to injection-related trauma and impurities within the formulation. The reactive oxygen species can oxidize TPs to alter their efficacy and immunogenicity potential. Mechanistic understandings of the dominant proteolysis and oxidative routes are useful in the drug discovery process, formulation development, and to assess the potential for immunogenicity and altered pharmacokinetics (PK). Furthermore, in vitro tools representing the ID or SC and lymphatic system can be used to evaluate the extent of proteolysis of the TPs after the injection and before systemic entry. The in vitro clearance data may be included in physiologically based pharmacokinetic models for improved PK predictions. In this review, we have summarized various physiological factors responsible for proteolysis and oxidation of TPs after ID and SC administration.
Collapse
Affiliation(s)
- Ninad Varkhede
- Department of Pharmaceutical Chemistry, The University of Kansas, Lawrence, Kansas 66047; Department of Pharmacokinetics, Pharmacodynamics & Drug Metabolism (PPDM), Merck Research Laboratories, West Point, Pennsylvania 19486
| | - Rupesh Bommana
- Department of Pharmaceutical Chemistry, The University of Kansas, Lawrence, Kansas 66047; MedImmune, Gaithersburg, Maryland 20878
| | - Christian Schöneich
- Department of Pharmaceutical Chemistry, The University of Kansas, Lawrence, Kansas 66047
| | - M Laird Forrest
- Department of Pharmaceutical Chemistry, The University of Kansas, Lawrence, Kansas 66047.
| |
Collapse
|
2
|
Samkoe KS, Park Y, Marra K, Chen EY, Tichauer KM. Paired-agent imaging for detection of head and neck cancers. PROCEEDINGS OF SPIE--THE INTERNATIONAL SOCIETY FOR OPTICAL ENGINEERING 2019; 10853. [PMID: 31686720 DOI: 10.1117/12.2510897] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 12/29/2022]
Abstract
Head and neck cancers overwhelmingly overexpress epidermal growth factor receptor (EGFR). This overexpression has been utilized for head and neck cancers using molecular targeted agents for therapy and cancer cell detection. Significant progress has been made in using EGFR-targeted fluorescent antibody and Affibody molecule agents for fluorescent guided surgery in head and neck cancers. Although success in achieving tumor-to-background ratio of 3-5 have been achieved, the field is limited by the non-specific fluorescence in normal tissues as well as EGFR specific fluorescence in the oral cavity. We propose that paired-agent imaging (PAI) could improve the contrast between tumor and normal tissue by removing the fluorescent signal arising from non-specific binding. Here, ABY-029 - an anti-EGFR Affibody molecule labeled with IRDye 800CW - and IRDye 680RD conjugated to Affibody Control Imaging Agent molecule (IR680-Affctrl) are used as targeted and untargeted control agents, respectively, in a panel of head and neck squamous cell carcinomas (HNSCC) to test the ability of PAI to increase tumor detection. Initial results demonstrate that binding potential, a value proportional to receptor concentration, correlates well to EGFR expression but experimental limitations prevented pixel-by-pixel analysis that was desired. Although promising, a more rigorous and well-defined experimental protocol is required to align ex vivo EGFR immunohistochemistry with in vivo binding potential and fluorescence intensity. Additionally, a new set of paired-agents, ABY-029 and IRDye 700DX, are successfully tested in naïve mice and will be carried forward for clinical translation.
Collapse
Affiliation(s)
- Kimberley S Samkoe
- Geisel School of Medicine, Dartmouth College, Hanover, NH 03755.,Department of Surgery, Dartmouth-Hitchcock, Lebanon, NH, 03756
| | | | - Kayla Marra
- Thayer School of Engineering at Dartmouth, Lebanon, NH, 03755
| | - Eunice Y Chen
- Geisel School of Medicine, Dartmouth College, Hanover, NH 03755
| | - Kenneth M Tichauer
- Department of Biomedical Engineering, llinois Institute of Technology, Chicago, Illinois, 60616
| |
Collapse
|
3
|
Paired-Agent Fluorescence Molecular Imaging of Sentinel Lymph Nodes Using Indocyanine Green as a Control Agent for Antibody-Based Targeted Agents. CONTRAST MEDIA & MOLECULAR IMAGING 2019; 2019:7561862. [PMID: 30718985 PMCID: PMC6335824 DOI: 10.1155/2019/7561862] [Citation(s) in RCA: 9] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 06/29/2018] [Revised: 10/28/2018] [Accepted: 12/13/2018] [Indexed: 01/10/2023]
Abstract
Purpose Paired-agent molecular imaging methods, which employ coadministration of an untargeted, "control" imaging agent with a targeted agent to correct for nonspecific uptake, have been demonstrated to detect 200 cancer cells in a mouse model of metastatic breast cancer. This study demonstrates that indocyanine green (ICG), which is approved for human use, is an ideal control agent for future paired-agent studies to facilitate eventual clinical translation. Methods The kinetics of ICG were compared with a known ideal control imaging agent, IRDye-700DX-labeled antibody in both healthy and metastatic rat popliteal lymph nodes after coadministration, intradermally in the footpad. Results The kinetics of ICG and antibody-based imaging agent in tumor-free rat lymph nodes demonstrated a strong correlation with each other (r = 0.98, p < 0.001) with a measured binding potential of -0.102 ± 0.03 at 20 min postagent injection, while the kinetics of ICG and targeted imaging agent shows significant separation in the metastatic lymph nodes. Conclusion This study indicated a potential for microscopic sensitivity to cancer spread in sentinel lymph nodes using ICG as a control agent for antibody-based molecular imaging assays.
Collapse
|
4
|
Li C, Torres VC, Tichauer KM. Noninvasive detection of cancer spread to lymph nodes: A review of molecular imaging principles and protocols. J Surg Oncol 2018; 118:301-314. [PMID: 30196532 DOI: 10.1002/jso.25124] [Citation(s) in RCA: 11] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/09/2018] [Accepted: 05/06/2018] [Indexed: 12/20/2022]
Abstract
Identification of cancer spread to tumor-draining lymph nodes offers critical information for guiding treatment in many cancer types. Current clinical methods of nodal staging are invasive and can have substantial negative side effects. Molecular imaging protocols have long been proposed as a less invasive means of nodal staging, having the potential to enable highly sensitive and specific evaluations. This review article summarizes the current status and future perspectives for molecular targeted nodal staging.
Collapse
Affiliation(s)
- Chengyue Li
- Department of Biomedical Engineering, Illinois Institute of Technology, Chicago, Illinois
| | - Veronica C Torres
- Department of Biomedical Engineering, Illinois Institute of Technology, Chicago, Illinois
| | - Kenneth M Tichauer
- Department of Biomedical Engineering, Illinois Institute of Technology, Chicago, Illinois
| |
Collapse
|
5
|
Samkoe KS, Bates BD, Tselepidakis NN, DSouza AV, Gunn JR, Ramkumar DB, Paulsen KD, Pogue BW, Henderson ER. Development and evaluation of a connective tissue phantom model for subsurface visualization of cancers requiring wide local excision. JOURNAL OF BIOMEDICAL OPTICS 2017; 22:1-12. [PMID: 29274143 PMCID: PMC5741805 DOI: 10.1117/1.jbo.22.12.121613] [Citation(s) in RCA: 18] [Impact Index Per Article: 2.6] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 04/21/2017] [Accepted: 12/01/2017] [Indexed: 05/14/2023]
Abstract
Wide local excision (WLE) of tumors with negative margins remains a challenge because surgeons cannot directly visualize the mass. Fluorescence-guided surgery (FGS) may improve surgical accuracy; however, conventional methods with direct surface tumor visualization are not immediately applicable, and properties of tissues surrounding the cancer must be considered. We developed a phantom model for sarcoma resection with the near-infrared fluorophore IRDye 800CW and used it to iteratively define the properties of connective tissues that typically surround sarcoma tumors. We then tested the ability of a blinded surgeon to resect fluorescent tumor-simulating inclusions with ∼1-cm margins using predetermined target fluorescence intensities and a Solaris open-air fluorescence imaging system. In connective tissue-simulating phantoms, fluorescence intensity decreased with increasing blood concentration and increased with increasing intralipid concentrations. Fluorescent inclusions could be resolved at ≥1-cm depth in all inclusion concentrations and sizes tested. When inclusion depth was held constant, fluorescence intensity decreased with decreasing volume. Using targeted fluorescence intensities, a blinded surgeon was able to successfully excise inclusions with ∼1-cm margins from fat- and muscle-simulating phantoms with inclusion-to-background contrast ratios as low as 2∶1. Indirect, subsurface FGS is a promising tool for surgical resection of cancers requiring WLE.
Collapse
Affiliation(s)
- Kimberley S. Samkoe
- Dartmouth-Hitchcock Medical Center, Department of Surgery, Lebanon, New Hampshire, United States
- Geisel School of Medicine at Dartmouth, Hanover, New Hampshire, United States
- Thayer School of Engineering at Dartmouth, Hanover, New Hampshire, United States
- Address all correspondence to: Kimberley S. Samkoe, E-mail:
| | - Brent D. Bates
- Geisel School of Medicine at Dartmouth, Hanover, New Hampshire, United States
| | - Niki N. Tselepidakis
- Thayer School of Engineering at Dartmouth, Hanover, New Hampshire, United States
| | - Alisha V. DSouza
- Thayer School of Engineering at Dartmouth, Hanover, New Hampshire, United States
| | - Jason R. Gunn
- Thayer School of Engineering at Dartmouth, Hanover, New Hampshire, United States
| | - Dipak B. Ramkumar
- Dartmouth-Hitchcock Medical Center, Department of Orthopaedics, Lebanon, New Hampshire, United States
| | - Keith D. Paulsen
- Geisel School of Medicine at Dartmouth, Hanover, New Hampshire, United States
- Thayer School of Engineering at Dartmouth, Hanover, New Hampshire, United States
| | - Brian W. Pogue
- Geisel School of Medicine at Dartmouth, Hanover, New Hampshire, United States
- Thayer School of Engineering at Dartmouth, Hanover, New Hampshire, United States
| | - Eric R. Henderson
- Dartmouth-Hitchcock Medical Center, Department of Orthopaedics, Lebanon, New Hampshire, United States
- White River Junction VAMC, White River Junction, Vermont, United States
| |
Collapse
|
6
|
Morley ST, Walsh MT, Newport DT. Opportunities for Studying the Hydrodynamic Context for Breast Cancer Cell Spread Through Lymph Flow. Lymphat Res Biol 2017; 15:204-219. [PMID: 28749743 DOI: 10.1089/lrb.2017.0005] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/06/2023] Open
Abstract
The lymphatic system serves as the primary route for the metastatic spread of breast cancer cells (BCCs). A scarcity of information exists with regard to the advection of BCCs in lymph flow and a fundamental understanding of the response of BCCs to the forces in the lymphatics needs to be established. This review summarizes the flow environment metastatic BCCs are exposed to in the lymphatics. Special attention is paid to the behavior of cells/particles in microflows in an attempt to elucidate the behavior of BCCs under lymph flow conditions (Reynolds number <1).
Collapse
Affiliation(s)
- Sinéad T Morley
- 1 Faculty of Science & Engineering, School of Engineering, Bernal Institute, University of Limerick , Limerick, Ireland
| | - Michael T Walsh
- 1 Faculty of Science & Engineering, School of Engineering, Bernal Institute, University of Limerick , Limerick, Ireland .,2 Health Research Institute, University of Limerick , Limerick, Ireland
| | - David T Newport
- 1 Faculty of Science & Engineering, School of Engineering, Bernal Institute, University of Limerick , Limerick, Ireland
| |
Collapse
|
7
|
DSouza AV, Marra K, Gunn JR, Samkoe KS, Pogue BW. Optical tracer size differences allow quantitation of active pumping rate versus Stokes-Einstein diffusion in lymphatic transport. JOURNAL OF BIOMEDICAL OPTICS 2016; 21:100501. [PMID: 27752703 PMCID: PMC5067306 DOI: 10.1117/1.jbo.21.10.100501] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 08/02/2016] [Accepted: 09/20/2016] [Indexed: 06/06/2023]
Abstract
Lymphatic uptake of interstitially administered agents occurs by passive convective–diffusive inflow driven by interstitial concentration and pressure, while the downstream lymphatic transport is facilitated by active propulsive contractions of lymphatic vessel walls. Near-infrared fluorescence imaging in mice was used to measure these central components of lymphatic transport for the first time, using two different-sized molecules––methylene blue (MB) and fluorescence-labeled antibody immunoglobulin G (IgG)-IRDye 680RD. This work confirms the hypothesis that lymphatic passive inflow and active propulsion rates can be separated based upon the relative differences in Stokes–Einstein diffusion coefficient. This coefficient specifically affects the passive-diffusive uptake when the interstitial volume and pressure are constant. Parameters such as mean time-to-peak signal, overall fluorescence signal intensities, and number of active peristaltic pulses, were estimated from temporal imaging data. While the mean time to attain peak signal representative of diffusion-dominated flow in the lymph vessels was 0.6±0.2??min for MB and 8±6??min for IgG, showing a size dependence, the active propulsion rates were 3.4±0.8??pulses/min and 3.3±0.5??pulses/min, respectively, appearing size independent. The propulsion rates for both dyes decreased with clearance from the interstitial injection-site, indicating intrinsic control of the smooth muscles in response to interstitial pressure. This approach to size-comparative agent flow imaging of lymphatic function can enable noninvasive characterization of diseases related to uptake and flow in lymph networks.
Collapse
Affiliation(s)
- Alisha V. DSouza
- Dartmouth College, Thayer School of Engineering, 14 Engineering Drive, Hanover, New Hampshire 03755, United States
| | - Kayla Marra
- Dartmouth College, Thayer School of Engineering, 14 Engineering Drive, Hanover, New Hampshire 03755, United States
| | - Jason R. Gunn
- Dartmouth College, Thayer School of Engineering, 14 Engineering Drive, Hanover, New Hampshire 03755, United States
| | - Kimberley S. Samkoe
- Dartmouth College, Thayer School of Engineering, 14 Engineering Drive, Hanover, New Hampshire 03755, United States
- Geisel School of Medicine, Department of Surgery, 1 Rope Ferry Road, Hanover, New Hampshire 03755, United States
| | - Brian W. Pogue
- Dartmouth College, Thayer School of Engineering, 14 Engineering Drive, Hanover, New Hampshire 03755, United States
- Geisel School of Medicine, Department of Surgery, 1 Rope Ferry Road, Hanover, New Hampshire 03755, United States
| |
Collapse
|