1
|
Wang Y, Chen S, Chen X, Xu Z, Lin K, Shi L, Mu Q, Liu L. Coaxial Bright and Dark Field Optical Coherence Tomography. IEEE Trans Biomed Eng 2024; 71:1879-1888. [PMID: 38231824 DOI: 10.1109/tbme.2024.3355174] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/19/2024]
Abstract
To improve the signal collection efficiency of Optical Coherence Tomography (OCT) for biomedical applications. A novel coaxial optical design was implemented, utilizing a wavefront-division beam splitter in the sample arm with a 45-degree rod mirror. This design allowed for the simultaneous collection of bright and dark field signals. The bright field signal was detected within its circular aperture in a manner similar to standard OCT, while the dark field signal passed through an annular-shaped aperture and was collected by the same spectrometer via a fiber array. This new configuration improved the signal collection efficiency by ∼3 dB for typical biological tissues. Dark-field OCT images were found to provide higher resolution, contrast and distinct information compared to standard bright-field OCT. By compounding bright and dark field images, speckle noise was suppressed by ∼ √2 . These advantages were validated using Teflon phantoms, chicken breast ex vivo, and human skin in vivo. This new OCT configuration significantly enhances signal collection efficiency and image quality, offering great potential for improving OCT technology with better depth, contrast, resolution, speckles, and signal-to-noise ratio. We believe that the bright and dark field signals will enable more comprehensive tissue characterization with the angled scattered light. This advancement will greatly promote the OCT technology in various clinical and biomedical research applications.
Collapse
|
2
|
Maltais-Tariant R, Itzamna Becerra-Deana R, Brais-Brunet S, Dehaes M, Boudoux C. Speckle contrast reduction through the use of a modally-specific photonic lantern for optical coherence tomography. BIOMEDICAL OPTICS EXPRESS 2023; 14:6250-6259. [PMID: 38420311 PMCID: PMC10898554 DOI: 10.1364/boe.504861] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 09/06/2023] [Revised: 10/31/2023] [Accepted: 11/02/2023] [Indexed: 03/02/2024]
Abstract
A few-mode optical coherence tomography (FM-OCT) system was developed around a 2 × 1 modally-specific photonic lantern (MSPL) centered at 1310 nm. The MSPL allowed FM-OCT to acquire two coregistered images with uncorrelated speckle patterns generated by their specific coherent spread function. Here, we showed that averaging such images in vitro and in vivo reduced the speckle contrast by up to 28% and increased signal-to-noise ratio (SNR) by up to 48% with negligible impact on image spatial resolution. This method is compatible with other speckle reduction techniques to further improve OCT image quality.
Collapse
Affiliation(s)
| | | | - Simon Brais-Brunet
- Research Centre, CHU Sainte-Justine, Montréal, Canada
- Université de Montréal, Institute of Biomedical Engineering, Montréal, Canada
| | - Mathieu Dehaes
- Research Centre, CHU Sainte-Justine, Montréal, Canada
- Université de Montréal, Institute of Biomedical Engineering, Montréal, Canada
- Université de Montréal, Department of Radiology, Radio-oncology and Nuclear Medicine, Montréal, Canada
| | - Caroline Boudoux
- Polytechnique Montréal, Department of Engineering Physics, Montréal, Canada
- Castor Optics, Saint-Laurent, Canada
- Research Centre, CHU Sainte-Justine, Montréal, Canada
| |
Collapse
|
3
|
Wolfgang M, Kern A, Deng S, Stranzinger S, Liu M, Drexler W, Leitgeb R, Haindl R. Ultra-high-resolution optical coherence tomography for the investigation of thin multilayered pharmaceutical coatings. Int J Pharm 2023; 643:123096. [PMID: 37268027 DOI: 10.1016/j.ijpharm.2023.123096] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/20/2023] [Revised: 05/25/2023] [Accepted: 05/26/2023] [Indexed: 06/04/2023]
Abstract
Optical Coherence Tomography (OCT) has recently gained attention as a promising technology for in-line monitoring of pharmaceutical film-coating processes for (single-layered) tablet coatings and end-point detection with commercial systems. An increasing interest in the investigation of multiparticulate dosage forms with mostly multi-layered coatings below 20 µm final film thickness demands advancement in OCT technology for pharmaceutical imaging. We present an ultra-high-resolution (UHR-) OCT and investigate its performance based on three different multiparticulate dosage forms with different layer structures (one single-layered, two multi-layered) with layer thicknesses in a range from 5 to 50 µm. The achieved system resolution of 2.4 µm (axial) and 3.4 µm (lateral, both in air) enables the assessment of defects, film thickness variability and morphological features within the coating, previously unattainable using OCT. Despite the high transverse resolution, the provided depth of field was found sufficient to reach the core region of all dosage forms under test. We further demonstrate an automated segmentation and evaluation of UHR-OCT images for coating thicknesses, where human experts struggle using today's standard OCT systems.
Collapse
Affiliation(s)
| | - Alice Kern
- Center for Medical Physics and Biomedical Engineering, Medical University of Vienna, Vienna, Austria
| | - Shiyu Deng
- Center for Medical Physics and Biomedical Engineering, Medical University of Vienna, Vienna, Austria
| | | | - Mengyang Liu
- Center for Medical Physics and Biomedical Engineering, Medical University of Vienna, Vienna, Austria; Singapore Eye Research Institute, Singapore National Eye Centre, Singapore, Singapore
| | - Wolfgang Drexler
- Center for Medical Physics and Biomedical Engineering, Medical University of Vienna, Vienna, Austria
| | - Rainer Leitgeb
- Center for Medical Physics and Biomedical Engineering, Medical University of Vienna, Vienna, Austria; Christian Doppler Laboratory OPTRAMED, Medical University of Vienna, Vienna, Austria.
| | - Richard Haindl
- Center for Medical Physics and Biomedical Engineering, Medical University of Vienna, Vienna, Austria; School of Chemistry, Chemical Engineering and Biotechnology, Nanyang Technological University, 62 Nanyang Drive, Singapore, Singapore; Singapore Eye Research Institute, Singapore National Eye Centre, Singapore, Singapore
| |
Collapse
|
4
|
Zheng K, Li W, Sun B, Wang Y, Guan C, Liu J, Shi J. Annular and unidirectional transverse scattering with high directivity based on magnetoelectric coupling. OPTICS EXPRESS 2023; 31:14037-14047. [PMID: 37157276 DOI: 10.1364/oe.485916] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/10/2023]
Abstract
Transverse scattering is a special directional scattering perpendicular to the propagation direction, which has attracted great interest due to its potential applications from directional antennas, optical metrology to optical sensing. Here we reveal annular transverse scattering and unidirectional transverse scattering by magnetoelectric coupling of Omega particle. The annular transverse scattering can be achieved by the longitudinal dipole mode of the Omega particle. Furthermore, we demonstrate the highly asymmetric unidirectional transverse scattering by adjusting the transverse electric dipole (ED) and longitudinal magnetic dipole (MD) modes. Meanwhile, the forward scattering and backward scattering are suppressed by the interference of transverse ED and longitudinal MD modes. In particular, the lateral force exerted on the particle is accompanied by the transverse scattering. Our results provide a useful toolset for manipulating light scattered by the particle and broaden the application range of the particle with magnetoelectric coupling.
Collapse
|
5
|
Iyer RR, Liu YZ, Renteria CA, Tibble BE, Choi H, Žurauskas M, Boppart SA. Ultra-parallel label-free optophysiology of neural activity. iScience 2022; 25:104307. [PMID: 35602935 PMCID: PMC9114528 DOI: 10.1016/j.isci.2022.104307] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/30/2021] [Revised: 02/18/2022] [Accepted: 04/22/2022] [Indexed: 01/21/2023] Open
Abstract
The electrical activity of neurons has a spatiotemporal footprint that spans three orders of magnitude. Traditional electrophysiology lacks the spatial throughput to image the activity of an entire neural network; besides, labeled optical imaging using voltage-sensitive dyes and tracking Ca2+ ion dynamics lack the versatility and speed to capture fast-spiking activity, respectively. We present a label-free optical imaging technique to image the changes to the optical path length and the local birefringence caused by neural activity, at 4,000 Hz, across a 200 × 200 μm2 region, and with micron-scale spatial resolution and 300-pm displacement sensitivity using Superfast Polarization-sensitive Off-axis Full-field Optical Coherence Microscopy (SPoOF OCM). The undulations in the optical responses from mammalian neuronal activity were matched with field-potential electrophysiology measurements and validated with channel blockers. By directly tracking the widefield neural activity at millisecond timescales and micrometer resolution, SPoOF OCM provides a framework to progress from low-throughput electrophysiology to high-throughput ultra-parallel label-free optophysiology.
Collapse
Affiliation(s)
- Rishyashring R. Iyer
- Beckman Institute for Advanced Science and Technology, University of Illinois at Urbana-Champaign, Urbana, IL, USA,Department of Electrical and Computer Engineering, University of Illinois at Urbana-Champaign, Urbana, IL, USA
| | - Yuan-Zhi Liu
- Beckman Institute for Advanced Science and Technology, University of Illinois at Urbana-Champaign, Urbana, IL, USA
| | - Carlos A. Renteria
- Beckman Institute for Advanced Science and Technology, University of Illinois at Urbana-Champaign, Urbana, IL, USA,Department of Bioengineering, University of Illinois at Urbana-Champaign, Urbana, IL, USA
| | - Brian E. Tibble
- Beckman Institute for Advanced Science and Technology, University of Illinois at Urbana-Champaign, Urbana, IL, USA
| | - Honggu Choi
- Beckman Institute for Advanced Science and Technology, University of Illinois at Urbana-Champaign, Urbana, IL, USA
| | - Mantas Žurauskas
- Beckman Institute for Advanced Science and Technology, University of Illinois at Urbana-Champaign, Urbana, IL, USA
| | - Stephen A. Boppart
- Beckman Institute for Advanced Science and Technology, University of Illinois at Urbana-Champaign, Urbana, IL, USA,Department of Electrical and Computer Engineering, University of Illinois at Urbana-Champaign, Urbana, IL, USA,Department of Bioengineering, University of Illinois at Urbana-Champaign, Urbana, IL, USA,Carle Illinois College of Medicine, University of Illinois at Urbana-Champaign, Urbana, IL, USA,Cancer Center at Illinois, University of Illinois at Urbana-Champaign, Urbana, IL, USA,Corresponding author
| |
Collapse
|
6
|
Valente D, Vienola KV, Zawadzki RJ, Jonnal RS. Simultaneous directional full-field OCT using path-length and carrier multiplexing. OPTICS EXPRESS 2021; 29:32179-32195. [PMID: 34615295 PMCID: PMC8687100 DOI: 10.1364/oe.435761] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 07/07/2021] [Revised: 09/02/2021] [Accepted: 09/07/2021] [Indexed: 06/13/2023]
Abstract
Full-field swept-source optical coherence tomography (FF-SS-OCT) is an emerging technology with potential applications in ophthalmic imaging, microscopy, metrology, and other domains. Here we demonstrate a novel method of multiplexing FF-SS-OCT signals using carrier modulation (CM). The principle of CM could be used to inspect various properties of the scattered light, e.g. its spectrum, polarization, Doppler shift, or distribution in the pupil. The last of these will be explored in this work, where CM was used to acquire images passing through two different optical pupils. The two pupils contained semicircular optical windows with perpendicular orientations, with each window permitting measurement of scattering anisotropy in one dimension by inducing an optical delay between the images formed by the two halves of the pupil. Together, the two forms of multiplexing permit measurement of differential scattering anisotropy in the x and y dimensions simultaneously. To demonstrate the feasibility of this technique our carrier multiplexed directional FF-OCT (CM-D-FF-OCT) system was used to acquire images of a microlens array, human hair, onion skin and in vivo human retina. The results of these studies are presented and briefly discussed in the context of future development and application of this technique.
Collapse
Affiliation(s)
- Denise Valente
- Vision Science and Advanced Retinal Imaging Laboratory (VSRI), Department of Ophthalmology and Vision Science, University of California Davis, Sacramento, CA 95817, USA
| | - Kari V. Vienola
- Vision Science and Advanced Retinal Imaging Laboratory (VSRI), Department of Ophthalmology and Vision Science, University of California Davis, Sacramento, CA 95817, USA
| | - Robert J. Zawadzki
- Vision Science and Advanced Retinal Imaging Laboratory (VSRI), Department of Ophthalmology and Vision Science, University of California Davis, Sacramento, CA 95817, USA
- EyePod Small Animal Ocular Imaging Laboratory, Department of Cell Biology and Human Anatomy, University of California Davis, Davis, CA 95616, USA
| | - Ravi S. Jonnal
- Vision Science and Advanced Retinal Imaging Laboratory (VSRI), Department of Ophthalmology and Vision Science, University of California Davis, Sacramento, CA 95817, USA
| |
Collapse
|
7
|
de Sivry-Houle MP, Beaudoin SB, Brais-Brunet S, Dehaes M, Godbout N, Boudoux C. All-fiber few-mode optical coherence tomography using a modally-specific photonic lantern. BIOMEDICAL OPTICS EXPRESS 2021; 12:5704-5719. [PMID: 34692210 PMCID: PMC8515961 DOI: 10.1364/boe.428101] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Received: 04/26/2021] [Revised: 06/29/2021] [Accepted: 07/21/2021] [Indexed: 05/13/2023]
Abstract
Optical coherence tomography (OCT) was recently performed using a few-mode (FM) fiber to increase contrast or improve resolution using a sequential time-domain demultiplexing scheme isolating the different interferometric signals of the mode-coupled backscattered light. Here, we present an all-fiber FM-OCT system based on a parallel modal demultiplexing scheme exploiting a novel modally-specific photonic lantern (MSPL). The MSPL allows for maximal fringe visibility for each fiber propagation mode in an all-fiber assembly which provides the robustness required for clinical applications. The custom-built MSPL was designed for OCT at 930 nm and is wavelength-independent over the broad OCT spectrum. We further present a comprehensive coupling model for the interpretation of FM-OCT images using the first two propagation modes of a few-mode fiber, validate its predictions, and demonstrate the technique using in vitro microbead phantoms and ex vivo biological samples.
Collapse
Affiliation(s)
| | | | - Simon Brais-Brunet
- Université de Montréal, Institute of Biomedical Engineering, Montréal (QC), Canada
| | - Mathieu Dehaes
- Université de Montréal, Institute of Biomedical Engineering, Montréal (QC), Canada
- Université de Montréal, Department of Radiology, Radio-oncology and Nuclear Medicine, Montréal (QC), Canada
- Research Centre, CHU Ste-Justine, Montréal (QC), Canada
| | - Nicolas Godbout
- Polytechnique Montréal, Engineering Physics Department, Montréal (QC), Canada
| | - Caroline Boudoux
- Polytechnique Montréal, Engineering Physics Department, Montréal (QC), Canada
- Research Centre, CHU Ste-Justine, Montréal (QC), Canada
| |
Collapse
|
8
|
Lochocki B, Morrema THJ, Ariese F, Hoozemans JJM, de Boer JF. The search for a unique Raman signature of amyloid-beta plaques in human brain tissue from Alzheimer's disease patients. Analyst 2020; 145:1724-1736. [PMID: 31907497 DOI: 10.1039/c9an02087j] [Citation(s) in RCA: 19] [Impact Index Per Article: 4.8] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/10/2023]
Abstract
Definite Alzheimer's disease (AD) diagnosis is commonly done on ex vivo brain tissue using immuno-histochemical staining to visualize amyloid-beta (Aβ) aggregates, also known as Aβ plaques. Raman spectroscopy has shown its potential for non-invasive and label-free determination of bio-molecular compositions, aiding the post-mortem diagnosis of pathological tissue. Here, we investigated whether conventional Raman spectroscopy could be used for the detection of amyloid beta deposits in fixed, ex vivo human brain tissue, taken from the frontal cortex region. We examined the spectra and spectral maps of three severe AD cases and two healthy control cases and compared their spectral outcome among each other as well as to recent results in the literature obtained with various spectroscopic techniques. After hyperspectral Raman mapping, Aβ plaques were visualized using Thioflavin-S staining on the exact same tissue sections. As a result, we show that tiny diffuse or tangled-like morphological structures, visible under microscopic conditions on unstained tissue and often but erroneously assumed to be deposits of Aβ, are instead usually an aggregation of highly auto-fluorescent lipofuscin granulates without any, or limited, plaque or plaque-like association. The occurrence of these auto-fluorescent particles is equally distributed in both AD and healthy control cases. Therefore, they cannot be used as possible criteria for Alzheimer's disease diagnosis. Furthermore, a unique plaque-specific/Aβ spectrum could not be determined even after possible spectral interferences were carefully removed.
Collapse
Affiliation(s)
- Benjamin Lochocki
- Department of Physics and Astronomy, LaserLaB Amsterdam, VU Amsterdam, The Netherlands.
| | - Tjado H J Morrema
- Department of Pathology, Amsterdam Neuroscience, Amsterdam University Medical Center, Amsterdam, The Netherlands
| | - Freek Ariese
- Department of Physics and Astronomy, LaserLaB Amsterdam, VU Amsterdam, The Netherlands.
| | - Jeroen J M Hoozemans
- Department of Pathology, Amsterdam Neuroscience, Amsterdam University Medical Center, Amsterdam, The Netherlands
| | - Johannes F de Boer
- Department of Physics and Astronomy, LaserLaB Amsterdam, VU Amsterdam, The Netherlands.
| |
Collapse
|
9
|
Meng Z, Ding L, Feng S, Xing F, Nie S, Ma J, Pedrini G, Yuan C. Numerical dark-field imaging using deep-learning. OPTICS EXPRESS 2020; 28:34266-34278. [PMID: 33182900 DOI: 10.1364/oe.401786] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Received: 07/23/2020] [Accepted: 10/20/2020] [Indexed: 06/11/2023]
Abstract
Dark-field microscopy is a powerful technique for enhancing the imaging resolution and contrast of small unstained samples. In this study, we report a method based on end-to-end convolutional neural network to reconstruct high-resolution dark-field images from low-resolution bright-field images. The relation between bright- and dark-field which was difficult to deduce theoretically can be obtained by training the corresponding network. The training data, namely the matched bright- and dark-field images of the same object view, are simultaneously obtained by a special designed multiplexed image system. Since the image registration work which is the key step in data preparation is not needed, the manual error can be largely avoided. After training, a high-resolution numerical dark-field image is generated from a conventional bright-field image as the input of this network. We validated the method by the resolution test target and quantitative analysis of the reconstructed numerical dark-field images of biological tissues. The experimental results show that the proposed learning-based method can realize the conversion from bright-field image to dark-field image, so that can efficiently achieve high-resolution numerical dark-field imaging. The proposed network is universal for different kinds of samples. In addition, we also verify that the proposed method has good anti-noise performance and is not affected by the unstable factors caused by experiment setup.
Collapse
|
10
|
Lichtenegger A, Gesperger J, Niederleithner M, Ginner L, Woehrer A, Drexler W, Baumann B, Leitgeb RA, Salas M. Ex-vivo Alzheimer's disease brain tissue investigation: a multiscale approach using 1060-nm swept source optical coherence tomography for a direct correlation to histology. NEUROPHOTONICS 2020; 7:035004. [PMID: 32855993 PMCID: PMC7441220 DOI: 10.1117/1.nph.7.3.035004] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 04/08/2020] [Accepted: 08/04/2020] [Indexed: 06/11/2023]
Abstract
Significance: Amyloid-beta ( A - β ) plaques are pathological protein deposits formed in the brain of Alzheimer's disease (AD) patients upon disease progression. Further research is needed to elucidate the complex underlying mechanisms involved in their formation using label-free, tissue preserving, and volumetric techniques. Aim: The aim is to achieve a one-to-one correlation of optical coherence tomography (OCT) data to histological micrographs of brain tissue using 1060-nm swept source OCT. Approach: A - β plaques were investigated in ex-vivo AD brain tissue using OCT with the capability of switching between two magnifications. For the exact correlation to histology, a 3D-printed tool was designed to generate samples with parallel flat surfaces. Large field-of-view (FoV) and sequentially high-resolution volumes at different locations were acquired. The large FoV served to align the OCT to histology images; the high-resolution images were used to visualize fine details. Results: The instrument and the presented method enabled an accurate correlation of histological micrographs with OCT data. A - β plaques were identified as hyperscattering features in both FoV OCT modalities. The plaques identified in volumetric OCT data were in good agreement with immunohistochemically derived micrographs. Conclusion: OCT combined with the 3D-printed tool is a promising approach for label-free, nondestructive, volumetric, and fast tissue analysis.
Collapse
Affiliation(s)
- Antonia Lichtenegger
- Medical University of Vienna, Center for Medical Physics and Biomedical Engineering, Vienna, Austria
| | - Johanna Gesperger
- Medical University of Vienna, Center for Medical Physics and Biomedical Engineering, Vienna, Austria
- Medical University of Vienna, Division of Neuropathology and Neurochemistry, Department of Neurology, Vienna, Austria
| | - Michael Niederleithner
- Medical University of Vienna, Center for Medical Physics and Biomedical Engineering, Vienna, Austria
| | - Laurin Ginner
- Medical University of Vienna, Center for Medical Physics and Biomedical Engineering, Vienna, Austria
- AIT Austrian Institute of Technology GmbH, Vienna, Austria
| | - Adelheid Woehrer
- Medical University of Vienna, Division of Neuropathology and Neurochemistry, Department of Neurology, Vienna, Austria
| | - Wolfgang Drexler
- Medical University of Vienna, Center for Medical Physics and Biomedical Engineering, Vienna, Austria
| | - Bernhard Baumann
- Medical University of Vienna, Center for Medical Physics and Biomedical Engineering, Vienna, Austria
| | - Rainer A. Leitgeb
- Medical University of Vienna, Center for Medical Physics and Biomedical Engineering, Vienna, Austria
- Medical University of Vienna, Christian Doppler Laboratory for Innovative Optical Imaging and its Translation to Medicine, Vienna, Austria
| | - Matthias Salas
- Medical University of Vienna, Center for Medical Physics and Biomedical Engineering, Vienna, Austria
- Medical University of Vienna, Division of Neuropathology and Neurochemistry, Department of Neurology, Vienna, Austria
| |
Collapse
|
11
|
Zhang H, Steelman ZA, Ceballos S, Chu KK, Wax A. Reconstruction of angle-resolved backscattering through a multimode fiber for cell nuclei and particle size determination. APL PHOTONICS 2020; 5:076105. [PMID: 36874207 PMCID: PMC9980710 DOI: 10.1063/5.0011500] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 04/21/2020] [Accepted: 06/25/2020] [Indexed: 06/18/2023]
Abstract
We demonstrate reconstruction of angle-resolved optical backscattering after transmission through a multimode fiber. Angle-resolved backscattering is an important tool for particle sizing, and has been developed as a diagnostic modality for detecting epithelial precancer. In this work, we fully characterized the transfer function of a multimode fiber using a plane-wave illumination basis across two dimensions. Once characterized, angle-resolved scattering information which has been scrambled by multimodal propagation can be easily and accurately reconstructed. Our technique was validated using a Mie theory-based inverse light scattering analysis (ILSA) algorithm on polystyrene microsphere phantoms of known sizes. To demonstrate the clinical potential of this approach, nuclear morphology was determined from the reconstructed angular backscattering from MCF-10A human mammary epithelial cell samples and validated against quantitative image analysis (QIA) of fluorescence microscopy images.
Collapse
Affiliation(s)
- Haoran Zhang
- Department of Biomedical Engineering, Duke University, Durham, NC, 227708, USA
| | - Zachary A Steelman
- Department of Biomedical Engineering, Duke University, Durham, NC, 227708, USA
| | - Silvia Ceballos
- Department of Biomedical Engineering, Duke University, Durham, NC, 227708, USA
| | - Kengyeh K Chu
- Department of Biomedical Engineering, Duke University, Durham, NC, 227708, USA
| | - Adam Wax
- Department of Biomedical Engineering, Duke University, Durham, NC, 227708, USA
| |
Collapse
|
12
|
Gardner MR, Baruah V, Vargas G, Motamedi M, Milner TE, Rylander HG. Scattering Angle Resolved Optical Coherence Tomography Detects Early Changes in 3xTg Alzheimer's Disease Mouse Model. Transl Vis Sci Technol 2020; 9:18. [PMID: 32821490 PMCID: PMC7401921 DOI: 10.1167/tvst.9.5.18] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/22/2019] [Accepted: 03/02/2020] [Indexed: 02/07/2023] Open
Abstract
Purpose Clinical intensity-based optical coherence tomographic retinal imaging is unable to resolve some of the earliest changes to Alzheimer's disease (AD) neurons. The aim of this pilot study was to demonstrate that scattering-angle-resolved optical coherence tomography (SAR-OCT), which is sensitive to changes in light scattering angle, is a candidate retinal imaging modality for early AD detection. SAR-OCT signal data may be sensitive to changes in intracellular constituent morphology that are not detectable with conventional OCT. Methods In this cross-sectional study, retinas of a triple transgenic mouse model of AD (3xTg-AD) were imaged alongside age-matched control mice (C57BL/6J) using SAR-OCT. A total of 32 mice (12 control, 20 3xTg-Ad) at four ages (10, 20, 30, and 45 weeks) were included in this cross-sectional study, and three retinal feature sets (scattering, thickness, and angiography) were examined between the disease and control groups. Results AD mice had significantly increased scattering diversity (lower SAR-OCT C parameter) at the earliest imaging time (10 weeks). Differences in the C parameter between AD and control mice were diminished at later times when both groups showed increased scattering diversity. AD mice have reduced retinal thickness compared to controls, particularly in central regions and superficial layers. No differences in vascular density or fractional blood volume between groups were detected. Conclusions SAR-OCT is sensitive to scattering angle changes in a 3xTg-AD mouse model and could provide early-stage biomarkers for neurodegenerative diseases such as AD. Translational Relevance Clinical OCT systems may be modified to record SAR-OCT images for non-invasive retinal diagnostic imaging of patients with neurodegenerative diseases such as AD.
Collapse
Affiliation(s)
- Michael R Gardner
- Department of Biomedical Engineering, The University of Texas at Austin, Austin, TX, USA.,Department of Biomedical Engineering, King Faisal University, Al-Hofuf, Al-Ahsa, Saudi Arabia
| | - Vikram Baruah
- Department of Biomedical Engineering, The University of Texas at Austin, Austin, TX, USA
| | - Gracie Vargas
- Center for Biomedical Engineering, The University of Texas Medical Branch, Galveston, TX, USA
| | - Massoud Motamedi
- Center for Biomedical Engineering, The University of Texas Medical Branch, Galveston, TX, USA
| | - Thomas E Milner
- Department of Biomedical Engineering, The University of Texas at Austin, Austin, TX, USA
| | - Henry G Rylander
- Department of Biomedical Engineering, The University of Texas at Austin, Austin, TX, USA
| |
Collapse
|
13
|
Eugui P, Harper DJ, Kummer S, Lichtenegger A, Gesperger J, Himmel T, Augustin M, Merkle CW, Glösmann M, Baumann B. Three-dimensional visualization of opacifications in the murine crystalline lens by in vivo optical coherence tomography. BIOMEDICAL OPTICS EXPRESS 2020; 11:2085-2097. [PMID: 32341868 PMCID: PMC7173898 DOI: 10.1364/boe.387335] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Received: 01/03/2020] [Revised: 03/05/2020] [Accepted: 03/12/2020] [Indexed: 05/03/2023]
Abstract
Diagnostic classification techniques used to diagnose cataracts, the world's leading cause of blindness, are currently based on subjective methods. Here, we present optical coherence tomography as a noninvasive tool for volumetric visualization of lesions formed in the crystalline lens. A custom-made swept-source optical coherence tomography (SS-OCT) system was utilized to investigate the murine crystalline lens. In addition to imaging cataractous lesions in aged wildtype mice, we studied the structure and shape of cataracts in a mouse model of Alzheimer's disease. Hyperscattering opacifications in the crystalline lens were observed in both groups. Post mortem histological analysis were performed to correlate findings in the anterior and posterior part of the lens to 3D OCT in vivo imaging. Our results showcase the capability of OCT to rapidly visualize cataractous lesions in the murine lens and suggest that OCT might be a valuable tool that provides additional insight for preclinical studies of cataract formation.
Collapse
Affiliation(s)
- Pablo Eugui
- Center for Medical Physics and Biomedical Engineering, Medical University of Vienna, Austria
| | - Danielle J. Harper
- Center for Medical Physics and Biomedical Engineering, Medical University of Vienna, Austria
| | - Stefan Kummer
- Core Facility for Research and Technology, University of Veterinary Medicine, Austria
| | - Antonia Lichtenegger
- Center for Medical Physics and Biomedical Engineering, Medical University of Vienna, Austria
| | - Johanna Gesperger
- Center for Medical Physics and Biomedical Engineering, Medical University of Vienna, Austria
- Division of Neuropathology and Neurochemistry, Department of Neurology of the Medical University of Vienna, Austria
| | - Tanja Himmel
- Core Facility for Research and Technology, University of Veterinary Medicine, Austria
| | - Marco Augustin
- Center for Medical Physics and Biomedical Engineering, Medical University of Vienna, Austria
| | - Conrad W. Merkle
- Center for Medical Physics and Biomedical Engineering, Medical University of Vienna, Austria
| | - Martin Glösmann
- Core Facility for Research and Technology, University of Veterinary Medicine, Austria
| | - Bernhard Baumann
- Center for Medical Physics and Biomedical Engineering, Medical University of Vienna, Austria
| |
Collapse
|
14
|
Eugui P, Harper DJ, Lichtenegger A, Augustin M, Merkle CW, Woehrer A, Hitzenberger CK, Baumann B. Polarization-sensitive imaging with simultaneous bright- and dark-field optical coherence tomography. OPTICS LETTERS 2019; 44:4040-4043. [PMID: 31415542 DOI: 10.1364/ol.44.004040] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Received: 05/24/2019] [Accepted: 07/04/2019] [Indexed: 05/20/2023]
Abstract
We present a polarization-sensitive (PS) extension for bright- and dark-field (BRAD) optical coherence tomography imaging. Using a few-mode fiber detection scheme, the light backscattered at different angles is separated, and the BRAD images of tissue scattering are generated. A calibration method to correct for the fiber birefringence is proposed. Since particle scattering profiles are polarization dependent, a PS detection extends the capabilities for investigating the scattering properties of biological tissues. Both phantoms consisting of different-sized microparticles and a brain tissue specimen were imaged to validate the system performance and demonstrate the complementary image contrast.
Collapse
|
15
|
Orth A, Ploschner M, Wilson ER, Maksymov IS, Gibson BC. Optical fiber bundles: Ultra-slim light field imaging probes. SCIENCE ADVANCES 2019; 5:eaav1555. [PMID: 31032405 PMCID: PMC6486219 DOI: 10.1126/sciadv.aav1555] [Citation(s) in RCA: 35] [Impact Index Per Article: 7.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 08/20/2018] [Accepted: 03/06/2019] [Indexed: 05/02/2023]
Abstract
Optical fiber bundle microendoscopes are widely used for visualizing hard-to-reach areas of the human body. These ultrathin devices often forgo tunable focusing optics because of size constraints and are therefore limited to two-dimensional (2D) imaging modalities. Ideally, microendoscopes would record 3D information for accurate clinical and biological interpretation, without bulky optomechanical parts. Here, we demonstrate that the optical fiber bundles commonly used in microendoscopy are inherently sensitive to depth information. We use the mode structure within fiber bundle cores to extract the spatio-angular description of captured light rays-the light field-enabling digital refocusing, stereo visualization, and surface and depth mapping of microscopic scenes at the distal fiber tip. Our work opens a route for minimally invasive clinical microendoscopy using standard bare fiber bundle probes. Unlike coherent 3D multimode fiber imaging techniques, our incoherent approach is single shot and resilient to fiber bending, making it attractive for clinical adoption.
Collapse
Affiliation(s)
- A. Orth
- ARC Centre of Excellence for Nanoscale BioPhotonics, School of Science, RMIT University, Melbourne, VIC 3000, Australia
- Corresponding author.
| | - M. Ploschner
- ARC Centre of Excellence for Nanoscale BioPhotonics, Department of Physics and Astronomy, Macquarie University, Sydney, NSW 2109, Australia
| | - E. R. Wilson
- ARC Centre of Excellence for Nanoscale BioPhotonics, School of Science, RMIT University, Melbourne, VIC 3000, Australia
| | - I. S. Maksymov
- ARC Centre of Excellence for Nanoscale BioPhotonics, School of Science, RMIT University, Melbourne, VIC 3000, Australia
- Centre for Micro-Photonics, Swinburne University of Technology, Hawthorn, VIC 3122, Australia
| | - B. C. Gibson
- ARC Centre of Excellence for Nanoscale BioPhotonics, School of Science, RMIT University, Melbourne, VIC 3000, Australia
| |
Collapse
|
16
|
Zhang H, Steelman ZA, Ho DS, Chu KK, Wax A. Angular range, sampling and noise considerations for inverse light scattering analysis of nuclear morphology. JOURNAL OF BIOPHOTONICS 2019; 12:e201800258. [PMID: 30239148 PMCID: PMC6375761 DOI: 10.1002/jbio.201800258] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 07/10/2018] [Accepted: 09/19/2018] [Indexed: 05/05/2023]
Abstract
In recent years, significant work has been devoted to the use of angle-resolved elastic scattering for the extraction of nuclear morphology in tissue. By treating the nucleus as a Mie scattering object, techniques such as angle-resolved low-coherence interferometry (a/LCI) have demonstrated substantial success in identifying nuclear alterations associated with dysplasia. Because optical biopsies are inherently noninvasive, only a small, discretized portion of the 4π scattering field can be collected from tissue, limiting the amount of information available for diagnostic purposes. In this work, we comprehensively characterize the diagnostic impact of variations in angular sampling, range and noise for inverse light scattering analysis of nuclear morphology, using a previously reported dataset from 40 patients undergoing a/LCI optical biopsy for cervical dysplasia. The results from this analysis are applied to a benchtop scanning a/LCI system which compromises angular range for wide-area scanning capability. This work will inform the design of next-generation optical biopsy probes by directing optical design towards parameters which offer the most diagnostic utility.
Collapse
Affiliation(s)
- Haoran Zhang
- Department of Biomedical Engineering, Duke University, Durham, NC, 27708, USA
| | - Zachary A. Steelman
- Department of Biomedical Engineering, Duke University, Durham, NC, 27708, USA
- Correspondence: Zachary A. Steelman, Department of Biomedical Engineering, Duke University, 101 Science Drive, Durham, NC, 27705, USA
| | - Derek S. Ho
- Department of Biomedical Engineering, Duke University, Durham, NC, 27708, USA
| | - Kengyeh K. Chu
- Department of Biomedical Engineering, Duke University, Durham, NC, 27708, USA
| | - Adam Wax
- Department of Biomedical Engineering, Duke University, Durham, NC, 27708, USA
| |
Collapse
|
17
|
Lichtenegger A, Muck M, Eugui P, Harper DJ, Augustin M, Leskovar K, Hitzenberger CK, Woehrer A, Baumann B. Assessment of pathological features in Alzheimer's disease brain tissue with a large field-of-view visible-light optical coherence microscope. NEUROPHOTONICS 2018; 5:035002. [PMID: 30137880 PMCID: PMC6057230 DOI: 10.1117/1.nph.5.3.035002] [Citation(s) in RCA: 9] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 03/29/2018] [Accepted: 07/09/2018] [Indexed: 05/18/2023]
Abstract
We implemented a wide field-of-view visible-light optical coherence microscope (OCM) for investigating ex-vivo brain tissue of patients diagnosed with Alzheimer's disease (AD) and of a mouse model of AD. A submicrometer axial resolution in tissue was achieved using a broad visible light spectrum. The use of various objective lenses enabled reaching micrometer transversal resolution and the acquisition of images of microscopic brain features, such as cell structures, vessels, and white matter tracts. Amyloid-beta plaques in the range of 10 to 70 μ m were visualized. Large field-of-view images of young and old mouse brain sections were imaged using an automated x - y - z stage. The plaque load was characterized, revealing an age-related increase. Human brain tissue affected by cerebral amyloid angiopathy was investigated and hyperscattering structures resembling amyloid beta accumulations in the vessel walls were identified. All results were in good agreement with histology. A comparison of plaque features in both human and mouse brain tissue was performed, revealing an increase in plaque load and a decrease in reflectivity for mouse as compared with human brain tissue. Based on the promising outcome of our experiments, visible light OCM might be a powerful tool for investigating microscopic features in ex-vivo brain tissue.
Collapse
Affiliation(s)
- Antonia Lichtenegger
- Medical University of Vienna, Center for Medical Physics and Biomedical Engineering, Vienna, Austria
| | - Martina Muck
- Medical University of Vienna, Center for Medical Physics and Biomedical Engineering, Vienna, Austria
- General Hospital and Medical University of Vienna, Institute of Neurology, Vienna, Austria
| | - Pablo Eugui
- Medical University of Vienna, Center for Medical Physics and Biomedical Engineering, Vienna, Austria
| | - Danielle J. Harper
- Medical University of Vienna, Center for Medical Physics and Biomedical Engineering, Vienna, Austria
| | - Marco Augustin
- Medical University of Vienna, Center for Medical Physics and Biomedical Engineering, Vienna, Austria
| | - Konrad Leskovar
- Medical University of Vienna, Center for Medical Physics and Biomedical Engineering, Vienna, Austria
- Vienna University of Technology, Institute of Applied Physics, Vienna, Austria
| | - Christoph K. Hitzenberger
- Medical University of Vienna, Center for Medical Physics and Biomedical Engineering, Vienna, Austria
| | - Adelheid Woehrer
- General Hospital and Medical University of Vienna, Institute of Neurology, Vienna, Austria
| | - Bernhard Baumann
- Medical University of Vienna, Center for Medical Physics and Biomedical Engineering, Vienna, Austria
| |
Collapse
|