1
|
Durst ME, Yurak S, Moscatelli J, Linhares I, Vargas R. Remote Focusing in a Temporal Focusing Microscope. OSA CONTINUUM 2021; 4:2757-2770. [PMID: 35531308 PMCID: PMC9075704 DOI: 10.1364/osac.443116] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 09/13/2021] [Accepted: 10/18/2021] [Indexed: 06/14/2023]
Abstract
In a temporal focusing microscope, dispersion can remotely shift the temporal focal plane axially, but only a single depth can be in focus at a time on a fixed camera. In this paper, we demonstrate remote focusing in a temporal focusing microscope. Dispersion tuning with an electrically tunable lens (ETL) in a 4 f pulse shaper scans the excitation plane axially, and another ETL in the detection path keeps the shifted excitation plane in focus on the camera. Image stacks formed using two ETLs versus a traditional stage scan are equivalent.
Collapse
|
2
|
Papagiakoumou E, Ronzitti E, Emiliani V. Scanless two-photon excitation with temporal focusing. Nat Methods 2020; 17:571-581. [PMID: 32284609 DOI: 10.1038/s41592-020-0795-y] [Citation(s) in RCA: 60] [Impact Index Per Article: 15.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/20/2019] [Accepted: 02/28/2020] [Indexed: 11/09/2022]
Abstract
Temporal focusing, with its ability to focus light in time, enables scanless illumination of large surface areas at the sample with micrometer axial confinement and robust propagation through scattering tissue. In conventional two-photon microscopy, widely used for the investigation of intact tissue in live animals, images are formed by point scanning of a spatially focused pulsed laser beam, resulting in limited temporal resolution of the excitation. Replacing point scanning with temporally focused widefield illumination removes this limitation and represents an important milestone in two-photon microscopy. Temporal focusing uses a diffusive or dispersive optical element placed in a plane conjugate to the objective focal plane to generate position-dependent temporal pulse broadening that enables axially confined multiphoton absorption, without the need for tight spatial focusing. Many techniques have benefitted from temporal focusing, including scanless imaging, super-resolution imaging, photolithography, uncaging of caged neurotransmitters and control of neuronal activity via optogenetics.
Collapse
Affiliation(s)
- Eirini Papagiakoumou
- Wavefront-Engineering Microscopy Group, Photonics Department, Institut de la Vision, Sorbonne University, Inserm S968, CNRS UMR7210, Fondation Voir et Entendre, Paris, France
| | - Emiliano Ronzitti
- Wavefront-Engineering Microscopy Group, Photonics Department, Institut de la Vision, Sorbonne University, Inserm S968, CNRS UMR7210, Fondation Voir et Entendre, Paris, France
| | - Valentina Emiliani
- Wavefront-Engineering Microscopy Group, Photonics Department, Institut de la Vision, Sorbonne University, Inserm S968, CNRS UMR7210, Fondation Voir et Entendre, Paris, France.
| |
Collapse
|
3
|
Durst ME, Turcios A, Laurence C, Moskovitz E. Dispersion compensation by a liquid lens (DisCoBALL). APPLIED OPTICS 2019; 58:428-435. [PMID: 30645323 PMCID: PMC6342488 DOI: 10.1364/ao.58.000428] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 09/25/2018] [Accepted: 12/11/2018] [Indexed: 06/09/2023]
Abstract
We present dispersion compensation by a liquid lens (DisCoBALL), which provides tunable group-delay dispersion (GDD) that is high speed, has a large tuning range, and uses off-the-shelf components. GDD compensation is crucial for experiments with ultrashort pulses. With an electrically tunable lens (ETL) at the Fourier plane of a 4f grating pair pulse shaper, the ETL applies a parabolic phase shift in space and therefore a parabolic phase shift to the laser spectrum, i.e., GDD. The GDD can be tuned with a range greater than 2×105 fs2 at a rate of 100 Hz while maintaining stable coupling into a single-mode fiber.
Collapse
|
4
|
Ronzitti E, Emiliani V, Papagiakoumou E. Methods for Three-Dimensional All-Optical Manipulation of Neural Circuits. Front Cell Neurosci 2018; 12:469. [PMID: 30618626 PMCID: PMC6304748 DOI: 10.3389/fncel.2018.00469] [Citation(s) in RCA: 17] [Impact Index Per Article: 2.8] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/04/2018] [Accepted: 11/19/2018] [Indexed: 12/18/2022] Open
Abstract
Optical means for modulating and monitoring neuronal activity, have provided substantial insights to neurophysiology and toward our understanding of how the brain works. Optogenetic actuators, calcium or voltage imaging probes and other molecular tools, combined with advanced microscopies have allowed an "all-optical" readout and modulation of neural circuits. Completion of this remarkable work is evolving toward a three-dimensional (3D) manipulation of neural ensembles at a high spatiotemporal resolution. Recently, original optical methods have been proposed for both activating and monitoring neurons in a 3D space, mainly through optogenetic compounds. Here, we review these methods and anticipate possible combinations among them.
Collapse
Affiliation(s)
| | | | - Eirini Papagiakoumou
- Wavefront Engineering Microscopy Group, Photonics Department, Institut de la Vision, Sorbonne Université, Inserm S968, CNRS UMR7210, Paris, France
| |
Collapse
|
5
|
Hernandez O, Pietrajtis K, Mathieu B, Dieudonné S. Optogenetic stimulation of complex spatio-temporal activity patterns by acousto-optic light steering probes cerebellar granular layer integrative properties. Sci Rep 2018; 8:13768. [PMID: 30213968 PMCID: PMC6137064 DOI: 10.1038/s41598-018-32017-w] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/01/2017] [Accepted: 08/28/2018] [Indexed: 12/11/2022] Open
Abstract
Optogenetics provides tools to control afferent activity in brain microcircuits. However, this requires optical methods that can evoke asynchronous and coordinated activity within neuronal ensembles in a spatio-temporally precise way. Here we describe a light patterning method, which combines MHz acousto-optic beam steering and adjustable low numerical aperture Gaussian beams, to achieve fast 2D targeting in scattering tissue. Using mossy fiber afferents to the cerebellar cortex as a testbed, we demonstrate single fiber optogenetic stimulation with micron-scale lateral resolution, >100 µm depth-penetration and 0.1 ms spiking precision. Protracted spatio-temporal patterns of light delivered by our illumination system evoked sustained asynchronous mossy fiber activity with excellent repeatability. Combining optical and electrical stimulations, we show that the cerebellar granular layer performs nonlinear integration, whereby sustained mossy fiber activity provides a permissive context for the transmission of salient inputs, enriching combinatorial views on mossy fiber pattern separation.
Collapse
Affiliation(s)
- Oscar Hernandez
- Institut de biologie de l'Ecole normale supérieure (IBENS), Ecole normale supérieure, CNRS, INSERM, PSL Université, 46 rue d'Ulm, 75005, Paris, France
- Wavefront-engineering Microscopy Group, Neurophotonics Laboratory, CNRS UMR8250, Paris Descartes University, Sorbonne Paris Cité, 45 rue des Saints-Pères, 75270, Paris Cedex 06, France
- CNC Program, Stanford University, Stanford, California, 94305, USA
| | - Katarzyna Pietrajtis
- Institut de biologie de l'Ecole normale supérieure (IBENS), Ecole normale supérieure, CNRS, INSERM, PSL Université, 46 rue d'Ulm, 75005, Paris, France
| | - Benjamin Mathieu
- Institut de biologie de l'Ecole normale supérieure (IBENS), Ecole normale supérieure, CNRS, INSERM, PSL Université, 46 rue d'Ulm, 75005, Paris, France
| | - Stéphane Dieudonné
- Institut de biologie de l'Ecole normale supérieure (IBENS), Ecole normale supérieure, CNRS, INSERM, PSL Université, 46 rue d'Ulm, 75005, Paris, France.
| |
Collapse
|
6
|
Sun B, Salter PS, Roider C, Jesacher A, Strauss J, Heberle J, Schmidt M, Booth MJ. Four-dimensional light shaping: manipulating ultrafast spatiotemporal foci in space and time. LIGHT, SCIENCE & APPLICATIONS 2018; 7:17117. [PMID: 30839626 PMCID: PMC6107044 DOI: 10.1038/lsa.2017.117] [Citation(s) in RCA: 46] [Impact Index Per Article: 7.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 05/14/2017] [Revised: 08/08/2017] [Accepted: 08/08/2017] [Indexed: 05/14/2023]
Abstract
The spectral dispersion of ultrashort pulses allows the simultaneous focusing of light in both space and time, which creates so-called spatiotemporal foci. Such space-time coupling may be combined with the existing holographic techniques to give a further dimension of control when generating focal light fields. In the present study, it is shown that a phase-only hologram placed in the pupil plane of an objective and illuminated by a spatially chirped ultrashort pulse can be used to generate three-dimensional arrays of spatio-temporally focused spots. By exploiting the pulse front tilt generated at focus when applying simultaneous spatial and temporal focusing (SSTF), it is possible to overlap neighboring foci in time to create a smooth intensity distribution. The resulting light field displays a high level of axial confinement, with experimental demonstrations given through two-photon microscopy and the non-linear laser fabrication of glass.
Collapse
Affiliation(s)
- Bangshan Sun
- Department of Engineering Science, University of Oxford, Parks Road, Oxford OX1 3PJ, UK
- Institute of Photonic Technologies, Friedrich-Alexander-University Erlangen-Nuremberg, Konrad-Zuse-Strasse 3/5, Erlangen 91052, Germany
| | - Patrick S Salter
- Department of Engineering Science, University of Oxford, Parks Road, Oxford OX1 3PJ, UK
| | - Clemens Roider
- Institute of Photonic Technologies, Friedrich-Alexander-University Erlangen-Nuremberg, Konrad-Zuse-Strasse 3/5, Erlangen 91052, Germany
- Division of Biomedical Physics, Innsbruck Medical University, Mullerstrasse 44, Innsbruck 6020, Austria
| | - Alexander Jesacher
- Division of Biomedical Physics, Innsbruck Medical University, Mullerstrasse 44, Innsbruck 6020, Austria
- Graduate School in Advanced Optical Technologies (SAOT), Friedrich-Alexander University Erlangen-Nuremberg, Paul-Gordan-Strasse 6, Erlangen 91052, Germany
| | - Johannes Strauss
- Institute of Photonic Technologies, Friedrich-Alexander-University Erlangen-Nuremberg, Konrad-Zuse-Strasse 3/5, Erlangen 91052, Germany
- Graduate School in Advanced Optical Technologies (SAOT), Friedrich-Alexander University Erlangen-Nuremberg, Paul-Gordan-Strasse 6, Erlangen 91052, Germany
| | - Johannes Heberle
- Institute of Photonic Technologies, Friedrich-Alexander-University Erlangen-Nuremberg, Konrad-Zuse-Strasse 3/5, Erlangen 91052, Germany
- Graduate School in Advanced Optical Technologies (SAOT), Friedrich-Alexander University Erlangen-Nuremberg, Paul-Gordan-Strasse 6, Erlangen 91052, Germany
| | - Michael Schmidt
- Institute of Photonic Technologies, Friedrich-Alexander-University Erlangen-Nuremberg, Konrad-Zuse-Strasse 3/5, Erlangen 91052, Germany
- Graduate School in Advanced Optical Technologies (SAOT), Friedrich-Alexander University Erlangen-Nuremberg, Paul-Gordan-Strasse 6, Erlangen 91052, Germany
| | - Martin J Booth
- Department of Engineering Science, University of Oxford, Parks Road, Oxford OX1 3PJ, UK
- Graduate School in Advanced Optical Technologies (SAOT), Friedrich-Alexander University Erlangen-Nuremberg, Paul-Gordan-Strasse 6, Erlangen 91052, Germany
- Centre for Neural Circuits and Behaviour, University of Oxford, Mansfield Road, Oxford OX1 3SR, UK
| |
Collapse
|
7
|
Hernandez O, Papagiakoumou E, Tanese D, Fidelin K, Wyart C, Emiliani V. Three-dimensional spatiotemporal focusing of holographic patterns. Nat Commun 2016; 7:11928. [PMID: 27306044 PMCID: PMC4912686 DOI: 10.1038/ncomms11928] [Citation(s) in RCA: 76] [Impact Index Per Article: 9.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/10/2015] [Accepted: 05/12/2016] [Indexed: 12/11/2022] Open
Abstract
Two-photon excitation with temporally focused pulses can be combined with phase-modulation approaches, such as computer-generated holography and generalized phase contrast, to efficiently distribute light into two-dimensional, axially confined, user-defined shapes. Adding lens-phase modulations to 2D-phase holograms enables remote axial pattern displacement as well as simultaneous pattern generation in multiple distinct planes. However, the axial confinement linearly degrades with lateral shape area in previous reports where axially shifted holographic shapes were not temporally focused. Here we report an optical system using two spatial light modulators to independently control transverse- and axial-target light distribution. This approach enables simultaneous axial translation of single or multiple spatiotemporally focused patterns across the sample volume while achieving the axial confinement of temporal focusing. We use the system's capability to photoconvert tens of Kaede-expressing neurons with single-cell resolution in live zebrafish larvae. Three-dimensional computer-generated holography cannot be implemented with temporal focusing. Here, Hernandez et al. use two spatial light modulators to control transverse- and axial-target light distribution, generating spatiotemporally focused patterns with uniform light distribution throughout the entire volume.
Collapse
Affiliation(s)
- Oscar Hernandez
- Wavefront-Engineering Microscopy Group, Neurophotonics Laboratory, CNRS UMR 8250, Paris Descartes University, UFR Biomédicale, 45 rue des Saints-Pères, 75270 Paris Cedex 06, France
| | - Eirini Papagiakoumou
- Wavefront-Engineering Microscopy Group, Neurophotonics Laboratory, CNRS UMR 8250, Paris Descartes University, UFR Biomédicale, 45 rue des Saints-Pères, 75270 Paris Cedex 06, France.,Institut national de la santé et de la recherche médicale (Inserm), France
| | - Dimitrii Tanese
- Wavefront-Engineering Microscopy Group, Neurophotonics Laboratory, CNRS UMR 8250, Paris Descartes University, UFR Biomédicale, 45 rue des Saints-Pères, 75270 Paris Cedex 06, France
| | - Kevin Fidelin
- Institut du Cerveau et de la Moelle Épinière, UPMC, Inserm UMR S975, CNRS UMR 7225, Campus Hospitalier Pitié Salpêtrière, 47 building de l'Hôpital, 75013 Paris, France
| | - Claire Wyart
- Institut du Cerveau et de la Moelle Épinière, UPMC, Inserm UMR S975, CNRS UMR 7225, Campus Hospitalier Pitié Salpêtrière, 47 building de l'Hôpital, 75013 Paris, France
| | - Valentina Emiliani
- Wavefront-Engineering Microscopy Group, Neurophotonics Laboratory, CNRS UMR 8250, Paris Descartes University, UFR Biomédicale, 45 rue des Saints-Pères, 75270 Paris Cedex 06, France
| |
Collapse
|
8
|
Spesyvtsev R, Rendall HA, Dholakia K. Wide-field three-dimensional optical imaging using temporal focusing for holographically trapped microparticles. OPTICS LETTERS 2015; 40:4847-50. [PMID: 26512465 DOI: 10.1364/ol.40.004847] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/26/2023]
Abstract
A contemporary challenge across the natural sciences is the simultaneous optical imaging or stimulation of small numbers of cells or colloidal particles organized into arbitrary geometries. We demonstrate the use of temporal focusing with holographic optical tweezers in order to achieve depth-resolved two-photon imaging of trapped objects arranged in arbitrary three-dimensional (3D) geometries using a single objective. Trapping allows for the independent position control of multiple objects by holographic beam shaping. Temporal focusing of ultrashort pulses provides the wide-field two-photon depth-selective activation of fluorescent samples. We demonstrate the wide-field depth-resolved illumination of both trapped fluorescent beads and trapped HL60 cells in suspension with full 3D positioning control. These approaches are compatible with implementation through scattering media and can be beneficial for emergent studies in colloidal science and particularly optogenetics, offering targeted photoactivation over a wide area with micrometer-precision depth control.
Collapse
|