1
|
Cao S, Chen R, Yang Q, He X, Chiavaioli F, Ran Y, Guan BO. Point-of-care diagnosis of pre-eclampsia based on microfiber Bragg grating biosensor. Biosens Bioelectron 2024; 249:116014. [PMID: 38219469 DOI: 10.1016/j.bios.2024.116014] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/07/2023] [Revised: 12/30/2023] [Accepted: 01/07/2024] [Indexed: 01/16/2024]
Abstract
Pre-eclampsia is a serious multi-organ complication that severely threatens the safety of pregnant women and infants. To accurate and timely diagnose pre-eclampsia, point-of-care (POC) biosensing of the specific biomarkers is urgently required. However, one of the key biomarkers of pre-eclampsia, placental growth factor (PlGF), has a reduced level of expression in patients, which challenges the quantification capability and Limit-of-detection (LOD) of biosensors. Herein, we reported a microfiber Bragg grating biosensor for the quantification of PlGF in clinical serum samples. The Bragg grating was inscribed in a unilateral tapered fiber to generate the segmented Fabry-Perot spectrum for improving the capability of detection. Furthermore, a temperature-calibrated Bragg grating was added to enable dual parametric detection of PlGF and temperature simultaneously for removing the crosstalk. Finally, the biosensor was envisaged to be perfectly compatible with microfluidic chips, and thus dramatically reducing the sample consumption to as small as 10 μL. The proposed biosensor can respond to PlGF with concentrations ranging from 5 to 120 pg mL-1, attaining a LOD of 5 pg mL-1 of clinical relevance. More importantly, the biosensor achieved micro volume detection of clinical serum samples from patients, and the ROC curve with an AUC of 0.977 confirmed the viability of the device. Our study paves the way to a new idea for cost-effective and high-precision screening of patients with pre-eclampsia, and hence envisages a promising prospect for point-of-care (POC) diagnosis of patients with pre-eclampsia.
Collapse
Affiliation(s)
- Shifang Cao
- Clinical Laboratory Center, The First Clinical Medical College, Jinan University, Guangzhou, 510630, China; Guangdong Provincial Key Laboratory of Optical Fiber Sensing and Communications, Institute of Photonics Technology, Jinan University, Guangzhou, 510632, China
| | - Ruiping Chen
- Department of Obstetrics and Gynecology, The First Clinical Medical College, Jinan University, Guangzhou, 510630, China.
| | - Qiaochu Yang
- Guangdong Provincial Key Laboratory of Optical Fiber Sensing and Communications, Institute of Photonics Technology, Jinan University, Guangzhou, 510632, China
| | - Xin He
- Clinical Laboratory Center, The First Clinical Medical College, Jinan University, Guangzhou, 510630, China.
| | - Francesco Chiavaioli
- National Research Council of Italy (CNR), Institute of Applied Physics "Nello Carrara", Sesto Fiorentino, 50019, Italy
| | - Yang Ran
- Guangdong Provincial Key Laboratory of Optical Fiber Sensing and Communications, Institute of Photonics Technology, Jinan University, Guangzhou, 510632, China.
| | - Bai-Ou Guan
- Guangdong Provincial Key Laboratory of Optical Fiber Sensing and Communications, Institute of Photonics Technology, Jinan University, Guangzhou, 510632, China
| |
Collapse
|
2
|
Harmonic optical microfiber Bragg grating immunosensor for the accelerative test of cardiac biomarker (cTn-I). Biosens Bioelectron 2021; 179:113081. [PMID: 33588296 DOI: 10.1016/j.bios.2021.113081] [Citation(s) in RCA: 22] [Impact Index Per Article: 7.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/03/2020] [Revised: 01/20/2021] [Accepted: 02/04/2021] [Indexed: 02/08/2023]
Abstract
Fiber-optic biosensor has shown tremendous promise in probing cardiac biomarkers label-free and in-operando. However, temperature cross-sensitivity is ubiquitously found and impedes further advances of the fiber-optic biosensors, especially for the scenario of rapid test at-body. In this study, we exploit a new regime that harnesses the harmonic resonances of a single microfiber Bragg grating to rule out the impact of the thermal noise. The reflections yielded by the harmonics can be engineered simultaneously at the two overriding optical wavebands, i.e., 1 μm and 1.55 μm, promising a remote acquisition of the sensing signals at patient by virtue of the Yb and/or Er-doped fiber amplifiers which are highly commercial. Furthermore, the functionality of the temperature-offset allows for the understanding of the biomolecular stimulating at the body temperature and thus facilitating the acceleration of the cardiac biomarker test. The proposed proof-of-concept enriches the arsenal of tools for fiber biosensors and enables a vista for the instant and in-vivo diagnosis of acute heart diseases.
Collapse
|
3
|
Kim S, Brady J, Al-Badani F, Yu S, Hart J, Jung S, Tran TT, Myung NV. Nanoengineering Approaches Toward Artificial Nose. Front Chem 2021; 9:629329. [PMID: 33681147 PMCID: PMC7935515 DOI: 10.3389/fchem.2021.629329] [Citation(s) in RCA: 9] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/14/2020] [Accepted: 01/05/2021] [Indexed: 12/16/2022] Open
Abstract
Significant scientific efforts have been made to mimic and potentially supersede the mammalian nose using artificial noses based on arrays of individual cross-sensitive gas sensors over the past couple decades. To this end, thousands of research articles have been published regarding the design of gas sensor arrays to function as artificial noses. Nanoengineered materials possessing high surface area for enhanced reaction kinetics and uniquely tunable optical, electronic, and optoelectronic properties have been extensively used as gas sensing materials in single gas sensors and sensor arrays. Therefore, nanoengineered materials address some of the shortcomings in sensitivity and selectivity inherent in microscale and macroscale materials for chemical sensors. In this article, the fundamental gas sensing mechanisms are briefly reviewed for each material class and sensing modality (electrical, optical, optoelectronic), followed by a survey and review of the various strategies for engineering or functionalizing these nanomaterials to improve their gas sensing selectivity, sensitivity and other measures of gas sensing performance. Specifically, one major focus of this review is on nanoscale materials and nanoengineering approaches for semiconducting metal oxides, transition metal dichalcogenides, carbonaceous nanomaterials, conducting polymers, and others as used in single gas sensors or sensor arrays for electrical sensing modality. Additionally, this review discusses the various nano-enabled techniques and materials of optical gas detection modality, including photonic crystals, surface plasmonic sensing, and nanoscale waveguides. Strategies for improving or tuning the sensitivity and selectivity of materials toward different gases are given priority due to the importance of having cross-sensitivity and selectivity toward various analytes in designing an effective artificial nose. Furthermore, optoelectrical sensing, which has to date not served as a common sensing modality, is also reviewed to highlight potential research directions. We close with some perspective on the future development of artificial noses which utilize optical and electrical sensing modalities, with additional focus on the less researched optoelectronic sensing modality.
Collapse
Affiliation(s)
- Sanggon Kim
- Department of Chemical and Environmental Engineering, University of California-Riverside, Riverside, CA, United States
| | - Jacob Brady
- Department of Chemical and Environmental Engineering, University of California-Riverside, Riverside, CA, United States
| | - Faraj Al-Badani
- Department of Chemical and Environmental Engineering, University of California-Riverside, Riverside, CA, United States
| | - Sooyoun Yu
- Department of Chemical and Biomolecular Engineering, University of Notre Dame, Notre Dame, IN, United States
| | - Joseph Hart
- Department of Chemical and Biomolecular Engineering, University of Notre Dame, Notre Dame, IN, United States
| | - Sungyong Jung
- Department of Electrical Engineering, University of Texas at Arlington, Arlington, TX, United States
| | - Thien-Toan Tran
- Department of Chemical and Biomolecular Engineering, University of Notre Dame, Notre Dame, IN, United States
| | - Nosang V. Myung
- Department of Chemical and Environmental Engineering, University of California-Riverside, Riverside, CA, United States
- Department of Chemical and Biomolecular Engineering, University of Notre Dame, Notre Dame, IN, United States
| |
Collapse
|
4
|
Micro-/Nanofiber Optics: Merging Photonics and Material Science on Nanoscale for Advanced Sensing Technology. iScience 2019; 23:100810. [PMID: 31931430 PMCID: PMC6957875 DOI: 10.1016/j.isci.2019.100810] [Citation(s) in RCA: 39] [Impact Index Per Article: 7.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/16/2019] [Revised: 11/24/2019] [Accepted: 12/23/2019] [Indexed: 12/13/2022] Open
Abstract
Micro-/nanofibers (MNFs) are optical fibers with diameters close to or below the wavelength of the guided light. These tiny fibers can offer engineerable waveguiding properties including optical confinement, fractional evanescent fields, and surface intensity, which is very attractive to optical sensing on the micro-/nano scale. In this review, we first introduce the basics of MNF optics and MNF optical sensors from physical and chemical to biological applications and review the progress and current status of this field. Then, we review and discuss hybrid MNF structures for advanced optical sensing by merging MNFs with functional structures including chemical indicators, quantum dots, dye molecules, plasmonic nanoparticles, 2-D materials, and optofluidic chips. Thirdly, we introduce the emerging trends in developing MNF-based advanced sensing technology for ultrasensitive, active, and wearable sensors and discuss the future prospects and challenges in this exciting research field. Finally, we end the review with a brief conclusion.
Collapse
|
5
|
Ran Y, Long J, Xu Z, Hu D, Guan BO. Temperature monitorable refractometer of microfiber Bragg grating using a duet of harmonic resonances. OPTICS LETTERS 2019; 44:3186-3189. [PMID: 31259917 DOI: 10.1364/ol.44.003186] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Received: 04/10/2019] [Accepted: 05/22/2019] [Indexed: 06/09/2023]
Abstract
To overcome the temperature cross-sensitivity of the microfiber Bragg grating (m-FBG) refractometer, we propose a novel refractive-index-temperature dual-sensing paradigm involving the third harmonic Bragg resonance that presents distinctive sensing characteristics. Strong resonances are obtained in both 1060 nm and 1550 nm wavebands under the modulation of the UV Talbot pattern. Moreover, higher-order transverse mode coupled resonance is also observed at the third harmonic waveband, supplementing an independent signal for enabling a sensing trio potentially. It is believed that the proposed dual-sensing paradigm would contribute to the m-FBT-based chemoprobes/bioprobes.
Collapse
|
6
|
High-Resolution Displacement Sensor Based on a Chirped Fabry–Pérot Interferometer Inscribed on a Tapered Microfiber. APPLIED SCIENCES-BASEL 2019. [DOI: 10.3390/app9030403] [Citation(s) in RCA: 6] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 11/16/2022]
Abstract
In this study, a high-resolution optical fiber Fabry–Pérot (FP) interferometer displacement sensor with chirped spectral characteristics based on a tapered microfiber is theoretically discussed and experimentally implemented. Instead of inscribing two fiber Bragg gratings (FBGs) on the symmetric position of the microfiber, we continuously inscribed one long FBG along the microfiber region to reduce the cavity length. The bandwidth of the interferometer is over 35 nm, and its displacement sensitivity is as high as 36.5 nm/mm at the tension state.
Collapse
|
7
|
Micro/Nanofibre Optical Sensors: Challenges and Prospects. SENSORS 2018; 18:s18030903. [PMID: 30720780 PMCID: PMC5876663 DOI: 10.3390/s18030903] [Citation(s) in RCA: 42] [Impact Index Per Article: 7.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 01/17/2018] [Revised: 02/21/2018] [Accepted: 02/23/2018] [Indexed: 01/24/2023]
Abstract
Micro/nanofibres (MNFs) are optical fibres with diameters close to or below the vacuum wavelength of visible or near-infrared light. Due to its wavelength- or sub-wavelength scale diameter and relatively large index contrast between the core and cladding, an MNF can offer engineerable waveguiding properties including optical confinement, fractional evanescent fields and surface intensity, which is very attractive to optical sensing on the micro and nanometer scale. In particular, the waveguided low-loss tightly confined large fractional evanescent fields, enabled by atomic level surface roughness and extraordinary geometric and material uniformity in a glass MNF, is one of its most prominent merits in realizing optical sensing with high sensitivity and great versatility. Meanwhile, the mesoporous matrix and small diameter of a polymer MNF, make it an excellent host fibre for functional materials for fast-response optical sensing. In this tutorial, we first introduce the basics of MNF optics and MNF optical sensors, and review the progress and current status of this field. Then, we discuss challenges and prospects of MNF sensors to some extent, with several clues for future studies. Finally, we conclude with a brief outlook for MNF optical sensors.
Collapse
|
8
|
A label-free cardiac biomarker immunosensor based on phase-shifted microfiber Bragg grating. Biosens Bioelectron 2018; 100:155-160. [DOI: 10.1016/j.bios.2017.08.061] [Citation(s) in RCA: 59] [Impact Index Per Article: 9.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/15/2017] [Revised: 08/18/2017] [Accepted: 08/30/2017] [Indexed: 11/20/2022]
|