1
|
Caiaffa CD, Ambekar YS, Singh M, Lin YL, Wlodarczyk B, Aglyamov SR, Scarcelli G, Larin KV, Finnell RH. Disruption of Fuz in mouse embryos generates hypoplastic hindbrain development and reduced cranial nerve ganglia. Dev Dyn 2024; 253:846-858. [PMID: 38501709 PMCID: PMC11411014 DOI: 10.1002/dvdy.702] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/08/2023] [Revised: 02/07/2024] [Accepted: 02/20/2024] [Indexed: 03/20/2024] Open
Abstract
BACKGROUND The brain and spinal cord formation is initiated in the earliest stages of mammalian pregnancy in a highly organized process known as neurulation. Environmental or genetic interferences can impair neurulation, resulting in clinically significant birth defects known collectively as neural tube defects. The Fuz gene encodes a subunit of the CPLANE complex, a macromolecular planar polarity effector required for ciliogenesis. Ablation of Fuz in mouse embryos results in exencephaly and spina bifida, including dysmorphic craniofacial structures due to defective cilia formation and impaired Sonic Hedgehog signaling. RESULTS We demonstrate that knocking Fuz out during embryonic mouse development results in a hypoplastic hindbrain phenotype, displaying abnormal rhombomeres with reduced length and width. This phenotype is associated with persistent reduction of ventral neuroepithelial stiffness in a notochord adjacent area at the level of the rhombomere 5. The formation of cranial and paravertebral ganglia is also impaired in these embryos. CONCLUSIONS This study reveals that hypoplastic hindbrain development, identified by abnormal rhombomere morphology and persistent loss of ventral neuroepithelial stiffness, precedes exencephaly in Fuz ablated murine mutants, indicating that the gene Fuz has a critical function sustaining normal neural tube development and neuronal differentiation.
Collapse
Affiliation(s)
- Carlo Donato Caiaffa
- Center for Precision Environmental Health, Baylor College of Medicine, Houston, TX, USA
- Department of Pediatrics, Dell Pediatric Research Institute, University of Texas at Austin Dell Medical School, Austin, TX, USA
| | | | - Manmohan Singh
- Department of Biomedical Engineering, University of Houston, Houston, TX, USA
| | - Ying Linda Lin
- Center for Precision Environmental Health, Baylor College of Medicine, Houston, TX, USA
| | - Bogdan Wlodarczyk
- Center for Precision Environmental Health, Baylor College of Medicine, Houston, TX, USA
| | - Salavat R. Aglyamov
- Department of Biomedical Engineering, University of Houston, Houston, TX, USA
| | - Giuliano Scarcelli
- Fischell Department of Bioengineering, University of Maryland, College Park, MD, USA
| | - Kirill V. Larin
- Department of Biomedical Engineering, University of Houston, Houston, TX, USA
- Department of Molecular Physiology and Biophysics, Baylor College of Medicine, Houston, TX, USA
| | - Richard H. Finnell
- Center for Precision Environmental Health, Baylor College of Medicine, Houston, TX, USA
- Department of Molecular and Cellular Biology, Molecular and Human Genetics and Medicine, Baylor College of Medicine, Houston, TX, USA
| |
Collapse
|
2
|
Mekonnen TT, Ambekar YS, Zevallos-Delgado C, Nair A, Zvietcovich F, Zarkoob H, Singh M, Lim YW, Ferrer M, Aglyamov SR, Scarcelli G, Song MJ, Larin KV. Dual optical elastography detects TGF - β -induced alterations in the biomechanical properties of skin scaffolds. JOURNAL OF BIOMEDICAL OPTICS 2024; 29:095002. [PMID: 39295639 PMCID: PMC11409821 DOI: 10.1117/1.jbo.29.9.095002] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 05/11/2024] [Revised: 08/27/2024] [Accepted: 09/03/2024] [Indexed: 09/21/2024]
Abstract
Significance The skin's mechanical properties are tightly regulated. Various pathologies can affect skin stiffness, and understanding these changes is a focus in tissue engineering. Ex vivo skin scaffolds are a robust platform for evaluating the effects of various genetic and molecular interactions on the skin. Transforming growth factor-beta ( TGF - β ) is a critical signaling molecule in the skin that can regulate the amount of collagen and elastin in the skin and, consequently, its mechanical properties. Aim This study investigates the biomechanical properties of bio-engineered skin scaffolds, focusing on the influence of TGF - β , a signaling molecule with diverse cellular functions. Approach The TGF - β receptor I inhibitor, galunisertib, was employed to assess the mechanical changes resulting from dysregulation of TGF - β . Skin scaffold samples, grouped into three categories (control, TGF - β -treated, and TGF - β + galunisertib-treated), were prepared in two distinct culture media-one with aprotinin (AP) and another without. Two optical elastography techniques, namely wave-based optical coherence elastography (OCE) and Brillouin microscopy, were utilized to quantify the biomechanical properties of the tissues. Results Results showed significantly higher wave speed (with AP, p < 0.001 ; without AP, p < 0.001 ) and Brillouin frequency shift (with AP, p < 0.001 ; without AP, p = 0.01 ) in TGF - β -treated group compared with the control group. The difference in wave speed between the control and TGF - β + galunisertib with ( p = 0.10 ) and without AP ( p = 0.36 ) was not significant. Moreover, the TGF - β + galunisertib-treated group exhibited lower wave speed without and with AP and reduced Brillouin frequency shift than the TGF - β -treated group without AP, further strengthening the potential role of TGF - β in regulating the mechanical properties of the samples. Conclusions These findings offer valuable insights into TGF - β -induced biomechanical alterations in bio-engineered skin scaffolds, highlighting the potential of OCE and Brillouin microscopy in the development of targeted therapies in conditions involving abnormal tissue remodeling and fibrosis.
Collapse
Affiliation(s)
- Taye T. Mekonnen
- University of Houston, Department of Biomedical Engineering, Houston, Texas, United States
- University of Sydney, Department of Mechanical Engineering, Sydney, New South Wales, Australia
| | - Yogeshwari S. Ambekar
- University of Houston, Department of Biomedical Engineering, Houston, Texas, United States
- University of Maryland, Fischell Department of Bioengineering, College Park, Maryland, United States
| | | | - Achuth Nair
- University of Houston, Department of Biomedical Engineering, Houston, Texas, United States
| | - Fernando Zvietcovich
- University of Houston, Department of Biomedical Engineering, Houston, Texas, United States
- Pontificia Universidad Catolica del Peru, Department of Engineering, Lima, Peru
| | - Hoda Zarkoob
- National Institutes of Health, National Center for Advancing Translational Sciences, Rockville, Maryland, United States
| | - Manmohan Singh
- University of Houston, Department of Biomedical Engineering, Houston, Texas, United States
| | - Yi Wei Lim
- National Institutes of Health, National Center for Advancing Translational Sciences, Rockville, Maryland, United States
| | - Marc Ferrer
- National Institutes of Health, National Center for Advancing Translational Sciences, Rockville, Maryland, United States
| | - Salavat R. Aglyamov
- University of Houston, Department of Mechanical Engineering, Houston, Texas, United States
| | - Giuliano Scarcelli
- University of Maryland, Fischell Department of Bioengineering, College Park, Maryland, United States
| | - Min Jae Song
- National Institutes of Health, National Center for Advancing Translational Sciences, Rockville, Maryland, United States
| | - Kirill V. Larin
- University of Houston, Department of Biomedical Engineering, Houston, Texas, United States
| |
Collapse
|
3
|
Yang F, Chen Z, Wang P, Shi Y. Phase-Domain Photoacoustic Mechanical Imaging for Quantitative Elastography and Viscography. IEEE Trans Biomed Eng 2024; 71:2330-2340. [PMID: 38381629 DOI: 10.1109/tbme.2024.3368150] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/23/2024]
Abstract
The role and importance of mechanical properties of cells and tissues in pathophysiological processes have widely been acknowledged. However, current elastography techniques most based on transverse elastic waves, diminish the translation of wave speed into elastic modulus due to its limited wave propagation direction. Here, we propose phase-domain photoacoustic mechanical imaging (PD-PAMI), leveraging the initial time and phase response characteristics of an omnidirectional photoacoustic elastic wave to quantitatively extract elastic and viscous moduli. Theoretical simulations and experiment on tissue-mimicking phantoms with different levels of viscoelastic properties were conducted to validate the approach with a precision in elasticity and viscosity estimation of 4.6% and 6.6%, respectively. The trans-scale viscoelasticity mappings over three length scales-covering cell, tissue section, and in vivo organ, were provided to demonstrate the scalability of the technique with different implementations of PD-PAMI. Experiments on animal models of breast tumour and atherosclerosis reveal that PD-PAMI technique enables effective monitoring of the viscoelastic parameters for examinations of the diseases involved with the variations in collagen or lipid composition and in inflammation level. PD-PAMI technique opens new perspectives of conventional PA imaging and provides new technical way for biomechanical imaging, prefiguring potential clinical applications in mechanopathology-involved disease diagnosis.
Collapse
|
4
|
Loveless BA, Moin KA, Hoopes PC, Moshirfar M. The Utilization of Brillouin Microscopy in Corneal Diagnostics: A Systematic Review. Cureus 2024; 16:e65769. [PMID: 39211657 PMCID: PMC11361473 DOI: 10.7759/cureus.65769] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Accepted: 07/26/2024] [Indexed: 09/04/2024] Open
Abstract
Corneal biomechanical data has been used since 2005 to screen for keratoconus and corneal ectasia by corneal specialists. Older technology uses force applanation techniques over a 3 mm area in the central cornea, making it highly dependent on extraneous variables and unable to calculate the elasticity of the tissue. Brillouin microscopy is a newer method that uses a natural shift in the frequency of light as it passes through a material. This frequency shift can be used to estimate the viscoelasticity of the tissue. The advantage of Brillouin microscopy is that it can create a full three-dimensional (3D) map of the entire cornea without direct contact. A literature search was conducted using the databases PubMed, Google Scholar, and Ovid regarding the applications of Brillouin microscopy in corneal diagnostics. A final total of 16 articles was included describing the various ex vivo and in vivo studies conducted using Brillouin microscopy. Applications of this technology spanned from keratoconus diagnosis to post-corneal refractive surgery evaluation. All studies evaluated corneal biomechanics and other corneal properties through the quantification of Brillouin frequency shifts. Many of the studies found that this diagnostic device is capable of detecting subtle changes in corneal thickness and biomechanics in keratoconic corneas at a high level of specificity and sensitivity. However, limitations of Brillouin microscopy may include the duration of time required for use and fluctuations in accuracy depending on the corneal hydration state. Future technology seems to be geared toward a combination of optical coherence tomography (OCT) and Brillouin microscopy, using OCT as a three-dimensional pupil-tracking modality. Further research and understanding of the technology involved will lead to better care of patients in the field of ophthalmology.
Collapse
Affiliation(s)
- Bosten A Loveless
- Ophthalmology, Hoopes Vision Research Center, Draper, USA
- Ophthalmology, Rocky Vista University College of Osteopathic Medicine, Ivins, USA
| | - Kayvon A Moin
- Ophthalmology, Hoopes Vision Research Center, Draper, USA
- Ophthalmology, American University of the Caribbean School of Medicine, Cupecoy, SXM
| | | | - Majid Moshirfar
- John A. Moran Eye Center, University of Utah School of Medicine, Salt Lake City, USA
- Ophthalmology, Hoopes Vision Research Center, Draper, USA
- Eye Banking and Corneal Transplantation, Utah Lions Eye Bank, Murray, USA
| |
Collapse
|
5
|
Ambekar YS, Caiaffa CD, Wlodarczyk BJ, Singh M, Schill AW, Steele JW, Zhang J, Aglyamov SR, Scarcelli G, Finnell RH, Larin KV. Optical coherence tomography-guided Brillouin microscopy highlights regional tissue stiffness differences during anterior neural tube closure in the Mthfd1l murine mutant. Development 2024; 151:dev202475. [PMID: 38682273 PMCID: PMC11165724 DOI: 10.1242/dev.202475] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/03/2023] [Accepted: 04/18/2024] [Indexed: 05/01/2024]
Abstract
Neurulation is a highly synchronized biomechanical process leading to the formation of the brain and spinal cord, and its failure leads to neural tube defects (NTDs). Although we are rapidly learning the genetic mechanisms underlying NTDs, the biomechanical aspects are largely unknown. To understand the correlation between NTDs and tissue stiffness during neural tube closure (NTC), we imaged an NTD murine model using optical coherence tomography (OCT), Brillouin microscopy and confocal fluorescence microscopy. Here, we associate structural information from OCT with local stiffness from the Brillouin signal of embryos undergoing neurulation. The stiffness of neuroepithelial tissues in Mthfd1l null embryos was significantly lower than that of wild-type embryos. Additionally, exogenous formate supplementation improved tissue stiffness and gross embryonic morphology in nullizygous and heterozygous embryos. Our results demonstrate the significance of proper tissue stiffness in normal NTC and pave the way for future studies on the mechanobiology of normal and abnormal embryonic development.
Collapse
Affiliation(s)
| | - Carlo Donato Caiaffa
- Center for Precision Environmental Health, Baylor College of Medicine, Houston, TX 77030, USA
- Department of Pediatrics, Dell Pediatric Research Institute, Dell Medical School, University of Texas at Austin, Austin, TX 78723, USA
| | - Bogdan J. Wlodarczyk
- Center for Precision Environmental Health, Baylor College of Medicine, Houston, TX 77030, USA
| | - Manmohan Singh
- Department of Biomedical Engineering, University of Houston, Houston, TX 77204, USA
| | - Alexander W. Schill
- Department of Biomedical Engineering, University of Houston, Houston, TX 77204, USA
| | - John W. Steele
- Center for Precision Environmental Health, Baylor College of Medicine, Houston, TX 77030, USA
| | - Jitao Zhang
- Department of Biomedical Engineering, Wayne State University, Detroit, MI 48201, USA
| | - Salavat R. Aglyamov
- Department of Mechanical Engineering, University of Houston, Houston, TX 77204, USA
| | - Giuliano Scarcelli
- Fischell Department of Bioengineering, University of Maryland, College Park, MD 20742, USA
| | - Richard H. Finnell
- Center for Precision Environmental Health, Baylor College of Medicine, Houston, TX 77030, USA
| | - Kirill V. Larin
- Department of Biomedical Engineering, University of Houston, Houston, TX 77204, USA
- Molecular Physiology and Biophysics, Baylor College of Medicine, Houston, TX 77030, USA
| |
Collapse
|
6
|
Romodina MN, Parmar A, Singh K. In vivo measurement of the biomechanical properties of human skin with motion-corrected Brillouin microscopy. BIOMEDICAL OPTICS EXPRESS 2024; 15:1777-1784. [PMID: 38495685 PMCID: PMC10942711 DOI: 10.1364/boe.516032] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 12/14/2023] [Revised: 01/18/2024] [Accepted: 01/30/2024] [Indexed: 03/19/2024]
Abstract
Biomechanical testing of human skin in vivo is important to study the aging process and pathological conditions such as skin cancer. Brillouin microscopy allows the all-optical, non-contact visualization of the mechanical properties of cells and tissues over space. Here, we use the combination of Brillouin microscopy and optical coherence tomography for motion-corrected, depth-resolved biomechanical testing of human skin in vivo. We obtained two peaks in the Brillouin spectra for the epidermis, the first at 7 GHz and the second near 9-10 GHz. The experimentally measured Brillouin frequency shift of the dermis is lower compared to the epidermis and is 6.8 GHz, indicating the lower stiffness of the dermis.
Collapse
Affiliation(s)
- Maria N. Romodina
- Max Planck Institute for the Science of Light, Staudtstr. 2, 91058 Erlangen, Germany
| | - Asha Parmar
- Max Planck Institute for the Science of Light, Staudtstr. 2, 91058 Erlangen, Germany
- Department of Physics, Friedrich Alexander University Erlangen-Nürnberg, Erlangen, Germany
| | - Kanwarpal Singh
- Max Planck Institute for the Science of Light, Staudtstr. 2, 91058 Erlangen, Germany
- Department of Physics, Friedrich Alexander University Erlangen-Nürnberg, Erlangen, Germany
- Department of Electrical and Computer Engineering, McMaster University, 1280 Main Street West, Hamilton, ON, L8S 4K1, Canada
| |
Collapse
|
7
|
Kabakova I, Zhang J, Xiang Y, Caponi S, Bilenca A, Guck J, Scarcelli G. Brillouin microscopy. NATURE REVIEWS. METHODS PRIMERS 2024; 4:8. [PMID: 39391288 PMCID: PMC11465583 DOI: 10.1038/s43586-023-00286-z] [Citation(s) in RCA: 1] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Accepted: 11/30/2023] [Indexed: 10/12/2024]
Abstract
The field of Brillouin microscopy and imaging was established approximately 20 years ago, thanks to the development of non-scanning high-resolution optical spectrometers. Since then, the field has experienced rapid expansion, incorporating technologies from telecommunications, astrophotonics, multiplexed microscopy, quantum optics and machine learning. Consequently, these advancements have led to much-needed improvements in imaging speed, spectral resolution and sensitivity. The progress in Brillouin microscopy is driven by a strong demand for label-free and contact-free methods to characterize the mechanical properties of biomaterials at the cellular and subcellular scales. Understanding the local biomechanics of cells and tissues has become crucial in predicting cellular fate and tissue pathogenesis. This Primer aims to provide a comprehensive overview of the methods and applications of Brillouin microscopy. It includes key demonstrations of Brillouin microscopy and imaging that can serve as a reference for the existing research community and new adopters of this technology. The article concludes with an outlook, presenting the authors' vision for future developments in this vibrant field. The Primer also highlights specific examples where Brillouin microscopy can have a transformative impact on biology and biomedicine.
Collapse
Affiliation(s)
- Irina Kabakova
- School of Mathematical and Physical Sciences, University of Technology Sydney, Sydney, New South Wales, Australia
| | - Jitao Zhang
- Department of Biomedical Engineering, Wayne State University, Detroit, MI, USA
| | - Yuchen Xiang
- Department of Metabolism, Digestion & Reproduction, Imperial College London, London, UK
| | - Silvia Caponi
- Istituto Officina dei Materiali–National Research Council (IOM-CNR)–Research Unit in Perugia, c/o Department of Physics and Geology, University of Perugia, Perugia, Italy
| | - Alberto Bilenca
- Biomedical Engineering Department, Ben-Gurion University of the Negev, Be’er-Sheva, Israel
| | - Jochen Guck
- Max Planck Institute for the Science of Light, Erlangen, Germany
- Max-Planck-Zentrum für Physik und Medizin, Erlangen, Germany
| | - Giuliano Scarcelli
- Fischell Department of Bioengineering, University of Maryland, College Park, MD, USA
- Maryland Biophysics Program, University of Maryland, College Park, MD, USA
| |
Collapse
|
8
|
Nair A, Zvietcovich F, Singh M, Weikert MP, Aglyamov SR, Larin KV. Optical coherence elastography measures the biomechanical properties of the ex vivo porcine cornea after LASIK. JOURNAL OF BIOMEDICAL OPTICS 2024; 29:016002. [PMID: 38223300 PMCID: PMC10787573 DOI: 10.1117/1.jbo.29.1.016002] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 09/15/2023] [Revised: 11/29/2023] [Accepted: 12/26/2023] [Indexed: 01/16/2024]
Abstract
Significance The biomechanical impact of refractive surgery has long been an area of investigation. Changes to the cornea structure cause alterations to its mechanical integrity, but few studies have examined its specific mechanical impact. Aim To quantify how the biomechanical properties of the cornea are altered by laser assisted in situ keratomileusis (LASIK) using optical coherence elastography (OCE) in ex vivo porcine corneas. Approach Three OCE techniques, wave-based air-coupled ultrasound (ACUS) OCE, heartbeat (Hb) OCE, and compression OCE were used to measure the mechanical properties of paired porcine corneas, where one eye of the pair was left untreated, and the fellow eye underwent LASIK. Changes in stiffness as a function of intraocular pressure (IOP) before and after LASIK were measured using each technique. Results ACUS-OCE showed that corneal stiffness changed as a function of IOP for both the untreated and the treated groups. The elastic wave speed after LASIK was lower than before LASIK. Hb-OCE and compression OCE showed regional changes in corneal strain after LASIK, where the absolute strain difference between the cornea anterior and posterior increased after LASIK. Conclusions The results of this study suggest that LASIK may soften the cornea and that these changes are largely localized to the region where the surgery was performed.
Collapse
Affiliation(s)
- Achuth Nair
- University of Houston, Department of Biomedical Engineering, Houston, Texas, United States
| | | | - Manmohan Singh
- University of Houston, Department of Biomedical Engineering, Houston, Texas, United States
| | - Mitchell P. Weikert
- Baylor College of Medicine, Cullen Eye Institute, Houston, Texas, United States
| | - Salavat R. Aglyamov
- University of Houston, Department of Mechanical Engineering, Houston, Texas, United States
| | - Kirill V. Larin
- University of Houston, Department of Biomedical Engineering, Houston, Texas, United States
- Baylor College of Medicine, Department of Physiology and Biophysics, Houston, Texas, United States
| |
Collapse
|
9
|
Yang F, Chen W, Chen Z. Photoacoustic micro-viscoelastography for mapping mechanocellular properties. JOURNAL OF BIOPHOTONICS 2024; 17:e202300262. [PMID: 37738101 DOI: 10.1002/jbio.202300262] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 07/08/2023] [Revised: 08/22/2023] [Accepted: 09/19/2023] [Indexed: 09/24/2023]
Abstract
Cellular biomechanical properties provide essential insights into biological functions regarding health and disease. Current measurements of the biomechanical properties of cells require physical contact with cells or pre-loading on the cells. Here, we have developed photoacoustic micro-viscoelastography (PAMVE), which utilizes the phase characteristics of photoacoustic (PA) response, for mapping mechanocellular properties in a load-free manner. PAMVE realizes the local viscoelasticity measurement on the macrophages and red blood cells with micrometer scale. Furthermore, PAMVE can successfully identify the adipose cell and skeletal muscle cell due to the difference in their composition-related biomechanical properties. PAMVE represents an irreplaceable option for interrogating characteristic mechanocellular properties, opening the possibility of studying cellular mechanobiology and pathophysiology.
Collapse
Affiliation(s)
- Fen Yang
- Department of Biomedical Engineering, Guangdong Provincial Key Laboratory of Advanced Biomaterials, Southern University of Science and Technology, Shenzhen, Guangdong, China
- MOE Key Laboratory of Laser Life Science and Institute of Laser Life Science, College of Biophotonics, South China Normal University, Guangzhou, China
| | - Wei Chen
- Department of Biomedical Engineering, Guangdong Provincial Key Laboratory of Advanced Biomaterials, Southern University of Science and Technology, Shenzhen, Guangdong, China
| | - Zhongjiang Chen
- School of Medical Technology and Engineering, Fujian Medical University, Fuzhou, China
| |
Collapse
|
10
|
Yang F, Ding W, Fu X, Chen W, Tang J. Photoacoustic elasto-viscography and optical coherence microscopy for multi-parametric ex vivo brain imaging. BIOMEDICAL OPTICS EXPRESS 2023; 14:5615-5628. [PMID: 38021134 PMCID: PMC10659785 DOI: 10.1364/boe.503847] [Citation(s) in RCA: 2] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Received: 08/24/2023] [Revised: 09/22/2023] [Accepted: 09/22/2023] [Indexed: 12/01/2023]
Abstract
Optical coherence microscopy (OCM) has shown the importance of imaging ex vivo brain slices at the microscopic level for a better understanding of the disease pathology and mechanism. However, the current OCM-based techniques are mainly limited to providing the tissue's optical properties, such as the attenuation coefficient, scattering coefficient, and cell architecture. Imaging the tissue's mechanical properties, including the elasticity and viscosity, in addition to the optical properties, to provide a comprehensive multi-parametric assessment of the sample has remained a challenge. Here, we present an integrated photoacoustic elasto-viscography (PAEV) and OCM imaging system to measure the sample's optical absorption coefficient, attenuation coefficient, and mechanical properties, including elasticity and viscosity. The obtained mechanical and optical properties were consistent with anatomical features observed in the PAEV and OCM images. The elasticity and viscosity maps showed rich variations of microstructural mechanical properties of mice brain. In the reconstructed elasto-viscogram of brain slices, greater elasticity, and lower viscosity were observed in white matter than in gray matter. With the ability to provide multi-parametric properties of the sample, the PAEV-OCM system holds the potential for a more comprehensive study of brain disease pathology.
Collapse
Affiliation(s)
- Fen Yang
- Department of Biomedical Engineering, Guangdong Provincial Key Laboratory of Advanced Biomaterials, Southern University of Science and Technology, Shenzhen, Guangdong 518055, China
| | - Wenguo Ding
- Department of Biomedical Engineering, Guangdong Provincial Key Laboratory of Advanced Biomaterials, Southern University of Science and Technology, Shenzhen, Guangdong 518055, China
| | - Xinlei Fu
- Department of Biomedical Engineering, Guangdong Provincial Key Laboratory of Advanced Biomaterials, Southern University of Science and Technology, Shenzhen, Guangdong 518055, China
| | - Wei Chen
- Department of Biomedical Engineering, Guangdong Provincial Key Laboratory of Advanced Biomaterials, Southern University of Science and Technology, Shenzhen, Guangdong 518055, China
| | - Jianbo Tang
- Department of Biomedical Engineering, Guangdong Provincial Key Laboratory of Advanced Biomaterials, Southern University of Science and Technology, Shenzhen, Guangdong 518055, China
| |
Collapse
|
11
|
Caiaffa CD, Ambekar YS, Singh M, Lin YL, Wlodarczyk B, Aglyamov SR, Scarcelli G, Larin KV, Finnell R. Disruption of Fuz in mouse embryos generates hypoplastic hindbrain development and reduced cranial nerve ganglia. BIORXIV : THE PREPRINT SERVER FOR BIOLOGY 2023:2023.08.04.552068. [PMID: 37577618 PMCID: PMC10418252 DOI: 10.1101/2023.08.04.552068] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 08/15/2023]
Abstract
The formation of the brain and spinal cord is initiated in the earliest stages of mammalian pregnancy in a highly organized process known as neurulation. Convergent and extension movements transforms a flat sheet of ectodermal cells into a narrow and elongated line of neuroepithelia, while a major source of Sonic Hedgehog signaling from the notochord induces the overlying neuroepithelial cells to form two apposed neural folds. Afterward, neural tube closure occurs by synchronized coordination of the surface ectoderm and adjacent neuroepithelial walls at specific axial regions known as neuropores. Environmental or genetic interferences can impair neurulation resulting in neural tube defects. The Fuz gene encodes a subunit of the CPLANE complex, which is a macromolecular planar polarity effector required for ciliogenesis. Ablation of Fuz in mouse embryos results in exencephaly and spina bifida, including dysmorphic craniofacial structures due to defective cilia formation and impaired Sonic Hedgehog signaling. In this work, we demonstrate that knocking Fuz out during embryonic mouse development results in a hypoplastic hindbrain phenotype, displaying abnormal rhombomeres with reduced length and width. This phenotype is associated with persistent loss of ventral neuroepithelial stiffness, in a notochord adjacent area at the level of the rhombomere 5, preceding the development of exencephaly in Fuz ablated mutants. The formation of cranial and paravertebral ganglia is also impaired in these embryos, indicating that Fuz has a critical function sustaining normal neural tube development and neuronal differentiation. SIGNIFICANCE STATEMENT Neural tube defects (NTDs) are a common cause of disability in children, representing the second most common congenital structural malformation in humans following only congenital cardiovascular malformations. NTDs affect approximately 1 to 2 pregnancies per 1000 births every year worldwide, when the mechanical forces folding the neural plate fails to close at specific neuropores located anteriorly (cranial) or posteriorly (caudal) along the neural tube, in a process known as neurulation, which happens throughout the third and fourth weeks of human pregnancy.
Collapse
|
12
|
Tomizawa Y, Daggett DF, Zheng G, Hoshino K. Light microscopy-based elastography for the mechanical characterization of zebrafish somitogenesis. JOURNAL OF BIOPHOTONICS 2023; 16:e202200238. [PMID: 36336921 DOI: 10.1002/jbio.202200238] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 07/25/2022] [Revised: 09/25/2022] [Accepted: 10/14/2022] [Indexed: 06/16/2023]
Abstract
We evaluated the elasticity of live tissues of zebrafish embryos using label-free optical elastography. We employed a pair of custom-built elastic microcantilevers to gently compress a zebrafish embryo and used optical-tracking analysis to obtain the induced internal strain. We then built a finite element method (FEM) model and matched the strain with the optical analysis. The elastic moduli were found by minimizing the root-mean-square errors between the optical and FEM analyses. We evaluated the average elastic moduli of a developing somite, the overlying ectoderm, and the underlying yolk of seven zebrafish embryos during the early somitogenesis stages. The estimation results showed that the average elastic modulus of the somite increased from 150 to 700 Pa between 4- and 8-somite stages, while those of the ectoderm and the yolk stayed between 100 and 200 Pa, and they did not show significant changes. The result matches well with the developmental process of somitogenesis reported in the literature. This is among the first attempts to quantify spatially-resolved elasticity of embryonic tissues from optical elastography.
Collapse
Affiliation(s)
- Yuji Tomizawa
- Department of Biomedical Engineering, University of Connecticut, Storrs, Connecticut, USA
| | - David F Daggett
- Department of Molecular and Cell Biology, University of Connecticut, Storrs, Connecticut, USA
| | - Guoan Zheng
- Department of Biomedical Engineering, University of Connecticut, Storrs, Connecticut, USA
| | - Kazunori Hoshino
- Department of Biomedical Engineering, University of Connecticut, Storrs, Connecticut, USA
| |
Collapse
|
13
|
Handler C, Scarcelli G, Zhang J. Time-lapse mechanical imaging of neural tube closure in live embryo using Brillouin microscopy. Sci Rep 2023; 13:263. [PMID: 36609620 PMCID: PMC9823106 DOI: 10.1038/s41598-023-27456-z] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/13/2022] [Accepted: 01/02/2023] [Indexed: 01/09/2023] Open
Abstract
Neural tube closure (NTC) is a complex process of embryonic development involving molecular, cellular, and biomechanical mechanisms. While the genetic factors and biochemical signaling have been extensively investigated, the role of tissue biomechanics remains mostly unexplored due to the lack of tools. Here, we developed an optical modality that can conduct time-lapse mechanical imaging of neural plate tissue as the embryo is experiencing neurulation. This technique is based on the combination of a confocal Brillouin microscope and a modified ex ovo culturing of chick embryo with an on-stage incubator. With this technique, for the first time, we captured the mechanical evolution of the neural plate tissue with live embryos. Specifically, we observed the continuous increase in tissue modulus of the neural plate during NTC for ex ovo cultured embryos, which is consistent with the data of in ovo culture as well as previous studies. Beyond that, we found that the increase in tissue modulus was highly correlated with the tissue thickening and bending. We foresee this non-contact and label-free technique opening new opportunities to understand the biomechanical mechanisms in embryonic development.
Collapse
Affiliation(s)
- Chenchen Handler
- grid.164295.d0000 0001 0941 7177Fischell Department of Bioengineering, A. James Clark School of Engineering, University of Maryland, College Park, MD 20742 USA
| | - Giuliano Scarcelli
- grid.164295.d0000 0001 0941 7177Fischell Department of Bioengineering, A. James Clark School of Engineering, University of Maryland, College Park, MD 20742 USA
| | - Jitao Zhang
- Department of Biomedical Engineering, Wayne State University, Detroit, MI, 48201, USA.
| |
Collapse
|
14
|
Nair A, Ambekar YS, Zevallos-Delgado C, Mekonnen T, Sun M, Zvietcovich F, Singh M, Aglyamov S, Koch M, Scarcelli G, Espana EM, Larin KV. Multiple Optical Elastography Techniques Reveal the Regulation of Corneal Stiffness by Collagen XII. Invest Ophthalmol Vis Sci 2022; 63:24. [PMID: 36383352 PMCID: PMC9680591 DOI: 10.1167/iovs.63.12.24] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/16/2022] [Accepted: 10/19/2022] [Indexed: 11/17/2022] Open
Abstract
Purpose Collagen XII plays a role in regulating the structure and mechanical properties of the cornea. In this work, several optical elastography techniques were used to investigate the effect of collagen XII deficiency on the stiffness of the murine cornea. Methods A three-prong optical elastography approach was used to investigate the mechanical properties of the cornea. Brillouin microscopy, air-coupled ultrasonic optical coherence elastography (OCE) and heartbeat OCE were used to assess the mechanical properties of wild type (WT) and collagen XII-deficient (Col12a1-/-) murine corneas. The Brillouin frequency shift, elastic wave speed, and compressive strain were all measured as a function of intraocular pressure (IOP). Results All three optical elastography modalities measured a significantly decreased stiffness in the Col12a1-/- compared to the WT (P < 0.01 for all three modalities). The optical coherence elastography techniques showed that mean stiffness increased as a function of IOP; however, Brillouin microscopy showed no discernable trend in Brillouin frequency shift as a function of IOP. Conclusions Our approach suggests that the absence of collagen XII significantly softens the cornea. Although both optical coherence elastography techniques showed an expected increase in corneal stiffness as a function of IOP, Brillouin microscopy did not show such a relationship, suggesting that the Brillouin longitudinal modulus may not be affected by changes in IOP. Future work will focus on multimodal biomechanical models, evaluating the effects of other collagen types on corneal stiffness, and in vivo measurements.
Collapse
Affiliation(s)
- Achuth Nair
- Department of Biomedical Engineering, University of Houston, Houston, TX, United States
| | - Yogeshwari S. Ambekar
- Department of Biomedical Engineering, University of Houston, Houston, TX, United States
| | | | - Taye Mekonnen
- Department of Biomedical Engineering, University of Houston, Houston, TX, United States
| | - Mei Sun
- Cornea and External Disease, Department of Ophthalmology, Morsani College of Medicine, University of South Florida, Tampa, Florida, United States
| | - Fernando Zvietcovich
- Department of Engineering, Pontificia Universidad Catolica del Peru, San Miguel, Lima, Peru
| | - Manmohan Singh
- Department of Biomedical Engineering, University of Houston, Houston, TX, United States
| | - Salavat Aglyamov
- Department of Mechanical Engineering, University of Houston, Houston, TX, United States
| | - Manuel Koch
- Institute for Dental Research and Oral Musculoskeletal Biology, Center for Molecular Medicine Cologne, and Center for Biochemistry, Medical Faculty, University of Cologne, Cologne, Germany
| | - Giuliano Scarcelli
- Fischell Department of Bioengineering, University of Maryland, College Park, MD, United States
| | - Edgar M. Espana
- Cornea and External Disease, Department of Ophthalmology, Morsani College of Medicine, University of South Florida, Tampa, Florida, United States
- Department of Molecular Pharmacology & Physiology, Morsani College of Medicine, University of South Florida, Tampa, Florida, United States
| | - Kirill V. Larin
- Department of Biomedical Engineering, University of Houston, Houston, TX, United States
- Department of Molecular Physiology and Biophysics, Baylor College of Medicine, Houston, Texas, United States
| |
Collapse
|