Diamond-Coated Silicon ATR Elements for Process Analytics. SENSORS 2021; 21:s21196442. [PMID: 34640761 PMCID: PMC8512763 DOI: 10.3390/s21196442] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 08/10/2021] [Revised: 09/09/2021] [Accepted: 09/20/2021] [Indexed: 11/17/2022]
Abstract
Infrared attenuated total reflection (ATR) spectroscopy is a common laboratory technique for the analysis of highly absorbing liquids or solid samples. However, ATR spectroscopy is rarely found in industrial processes, where inline measurement, continuous operation, and minimal maintenance are important issues. Most materials for mid-infrared (MIR) spectroscopy and specifically for ATR elements do not have either high enough infrared transmission or sufficient mechanical and chemical stability to be exposed to process fluids, abrasive components, and aggressive cleaning agents. Sapphire is the usual choice for infrared wavelengths below 5 µm, and beyond that, only diamond is an established material. The use of diamond coatings on other ATR materials such as silicon will increase the stability of the sensor and will enable the use of larger ATR elements with increased sensitivity at lower cost for wavelengths above 5 µm. Theoretical and experimental investigations of the dependence of ATR absorbances on the incidence angle and thickness of nanocrystalline diamond (NCD) coatings on silicon were performed. By optimizing the coating thickness, a substantial amplification of the ATR absorbance can be achieved compared to an uncoated silicon element. Using a compact FTIR instrument, ATR spectra of water, acetonitrile, and propylene carbonate were measured with planar ATR elements made of coated and uncoated silicon. Compared to sapphire, the long wavelength extreme of the spectral range is extended to approximately 8 μm. With effectively nine ATR reflections, the sensitivity is expected to exceed the performance of typical diamond tip probes.
Collapse
|
2
|
Cylindrical IR-ATR Sensors for Process Analytics. SENSORS 2020; 20:s20102917. [PMID: 32455667 PMCID: PMC7284823 DOI: 10.3390/s20102917] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 04/25/2020] [Revised: 05/18/2020] [Accepted: 05/19/2020] [Indexed: 11/18/2022]
Abstract
Infrared attenuated total reflection (ATR) spectroscopy is a common laboratory technique for the analysis of highly absorbing liquids and solids. However, in a process environment, maintaining a sufficient sample exchange and cleaning of the sensitive surface of the element is a crucial issue. An important industrial application is the measurement of isocyanate concentrations. Isocyanates are necessary for the fabrication of polyurethane materials and are among the chemicals with the highest production volume worldwide. For process applications, narrowband photometers or MEMS spectrometers are more appropriate than the use of bulky FTIR instruments frequently encountered in a laboratory environment. Toluene diisocyanate (TDI) and hexamethylene diisocyanate (HDI) concentrations are measured with a planar ATR photometer setup. Using a miniature Fabry–Perot interferometer (FPI), trace concentrations below 100 ppm (m/m) are detected. By employing an ATR element of the cylindrical shape, sensors can be realized with a smooth surface ideally suited for an automatic cleaning system in a process environment. A laboratory setup with sapphire tubes as ATR elements for incorporation in a liquid flow system is described. Reflection and transmission configurations were investigated. Measurements with acetonitrile as a less toxic substitute showed that with cylindrical ATR sensors’ detection limits for isocyanate concentrations below 100 ppm (m/m) are feasible.
Collapse
|
3
|
Rassel S, Xu C, Zhang S, Ban D. Noninvasive blood glucose detection using a quantum cascade laser. Analyst 2020; 145:2441-2456. [PMID: 32167098 DOI: 10.1039/c9an02354b] [Citation(s) in RCA: 13] [Impact Index Per Article: 3.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/09/2023]
Abstract
A Quantum Cascade Laser (QCL) was invented in the late 90s as a promising mid-infrared light source and it has contributed to the fields of industry, military, medicine, and biology. The room temperature operation, watt-level output power, compact size, and wide tuning capability of this laser advanced the field of noninvasive blood glucose detection with the use of transmission, absorption, and photoacoustic spectroscopy. This review provides a complete overview of the recent progress and technical details of these spectroscopy techniques, using QCL as an infrared light source for detecting blood glucose concentrations in diabetic patients.
Collapse
Affiliation(s)
- Shazzad Rassel
- Waterloo Institute for Nanotechnology and Department of Electrical and Computer Engineering, University of Waterloo, 200 University Ave W, Waterloo, ON N2L 3G1, Canada.
| | | | | | | |
Collapse
|
4
|
Infrared Spectroscopy with a Fiber-Coupled Quantum Cascade Laser for Attenuated Total Reflection Measurements Towards Biomedical Applications. SENSORS 2019; 19:s19235130. [PMID: 31771133 PMCID: PMC6929073 DOI: 10.3390/s19235130] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 10/15/2019] [Revised: 11/12/2019] [Accepted: 11/20/2019] [Indexed: 12/18/2022]
Abstract
The development of rapid and accurate biomedical laser spectroscopy systems in the mid-infrared has been enabled by the commercial availability of external-cavity quantum cascade lasers (EC-QCLs). EC-QCLs are a preferable alternative to benchtop instruments such as Fourier transform infrared spectrometers for sensor development as they are small and have high spectral power density. They also allow for the investigation of multiple analytes due to their broad tuneability and through the use of multivariate analysis. This article presents an in vitro investigation with two fiber-coupled measurement setups based on attenuated total reflection spectroscopy and direct transmission spectroscopy for sensing. A pulsed EC-QCL (1200–900 cm−1) was used for measurements of glucose and albumin in aqueous solutions, with lactate and urea as interferents. This analyte composition was chosen as an example of a complex aqueous solution with relevance for biomedical sensors. Glucose concentrations were determined in both setup types with root-mean-square error of cross-validation (RMSECV) of less than 20 mg/dL using partial least-squares (PLS) regression. These results demonstrate accurate analyte measurements, and are promising for further development of fiber-coupled, miniaturised in vivo sensors based on mid-infrared spectroscopy.
Collapse
|
5
|
Isensee K, Kröger-Lui N, Petrich W. Biomedical applications of mid-infrared quantum cascade lasers - a review. Analyst 2019; 143:5888-5911. [PMID: 30444222 DOI: 10.1039/c8an01306c] [Citation(s) in RCA: 27] [Impact Index Per Article: 5.4] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/24/2022]
Abstract
Mid-infrared spectroscopy has been applied to research in biology and medicine for more than 20 years and conceivable applications have been identified. More recently, these applications have been shown to benefit from the use of quantum cascade lasers due to their specific properties, namely high spectral power density, small beam parameter product, narrow emission spectrum and, if needed, tuning capabilities. This review provides an overview of the achievements and illustrates some applications which benefit from the key characteristics of quantum cascade laser-based mid-infrared spectroscopy using examples such as breath analysis, the investigation of serum, non-invasive glucose monitoring in bulk tissue and the combination of spectroscopy and microscopy of tissue thin sections for rapid histopathology.
Collapse
Affiliation(s)
- Katharina Isensee
- Kirchhoff-Institute for Physics, Heidelberg University, INF 277, 69120 Heidelberg, Germany.
| | | | | |
Collapse
|
6
|
Schwaighofer A, Brandstetter M, Lendl B. Quantum cascade lasers (QCLs) in biomedical spectroscopy. Chem Soc Rev 2017; 46:5903-5924. [DOI: 10.1039/c7cs00403f] [Citation(s) in RCA: 102] [Impact Index Per Article: 14.6] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/16/2022]
Abstract
This review focuses on the recent applications of QCLs in mid-IR spectroscopy of clinically relevant samples.
Collapse
Affiliation(s)
- Andreas Schwaighofer
- Institute of Chemical Technologies and Analytics
- Vienna University of Technology
- 1060 Vienna
- Austria
| | | | - Bernhard Lendl
- Institute of Chemical Technologies and Analytics
- Vienna University of Technology
- 1060 Vienna
- Austria
| |
Collapse
|
7
|
Li D, Yu S, Sun C, Zou C, Yu H, Xu K. U-shaped fiber-optic ATR sensor enhanced by silver nanoparticles for continuous glucose monitoring. Biosens Bioelectron 2015; 72:370-5. [DOI: 10.1016/j.bios.2015.05.023] [Citation(s) in RCA: 15] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/16/2015] [Revised: 05/09/2015] [Accepted: 05/09/2015] [Indexed: 10/23/2022]
|
8
|
Lambrecht A, Pfeifer M, Konz W, Herbst J, Axtmann F. Broadband spectroscopy with external cavity quantum cascade lasers beyond conventional absorption measurements. Analyst 2015; 139:2070-8. [PMID: 24367797 DOI: 10.1039/c3an01457f] [Citation(s) in RCA: 30] [Impact Index Per Article: 3.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/21/2022]
Abstract
Laser spectroscopy is a powerful tool for analyzing small molecules, i.e. in the gas phase. In the mid-infrared spectral region quantum cascade lasers (QCLs) have been established as the most frequently used laser radiation source. Spectroscopy of larger molecules in the gas phase, of complex mixtures, and analysis in the liquid phase requires a broader tuning range and is thus still the domain of Fourier transform infrared (FTIR) spectroscopy. However, the development of tunable external cavity (EC) QCLs is starting to change this situation. The main advantage of QCLs is their high spectral emission power that is enhanced by a factor of 10(4) compared with thermal light sources. Obviously, transmission measurements with EC-QCLs in strongly absorbing samples are feasible, which can hardly be measured by FTIR due to detector noise limitations. We show that the high power of EC-QCLs facilitates spectroscopy beyond simple absorption measurements. Starting from QCL experiments with liquid samples, we show results of fiber evanescent field analysis (FEFA) to detect pesticides in drinking water. FEFA is a special case of attenuated total reflection spectroscopy. Furthermore, powerful CW EC-QCLs enable fast vibrational circular dichroism (VCD) spectroscopy of chiral molecules in the liquid phase - a technique which is very time consuming with standard FTIR equipment. We present results obtained for the chiral compound 1,1'-bi-2-naphthol (BINOL). Finally, powerful CW EC-QCLs enable the application of laser photothermal emission spectroscopy (LPTES). We demonstrate this for a narrowband and broadband absorber in the gas phase. All three techniques have great potential for MIR process analytical applications.
Collapse
Affiliation(s)
- Armin Lambrecht
- Fraunhofer Institut für Physikalische Messtechnik, Heidenhofstr. 8, 79110 Freiburg, Germany.
| | | | | | | | | |
Collapse
|
9
|
Yu S, Li D, Chong H, Sun C, Yu H, Xu K. In vitro glucose measurement using tunable mid-infrared laser spectroscopy combined with fiber-optic sensor. BIOMEDICAL OPTICS EXPRESS 2013; 5:275-86. [PMID: 24466493 PMCID: PMC3891338 DOI: 10.1364/boe.5.000275] [Citation(s) in RCA: 9] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 10/21/2013] [Revised: 12/06/2013] [Accepted: 12/07/2013] [Indexed: 05/20/2023]
Abstract
Because mid-infrared (mid-IR) spectroscopy is not a promising method to noninvasively measure glucose in vivo, a method for minimally invasive high-precision glucose determination in vivo by mid-IR laser spectroscopy combined with a tunable laser source and small fiber-optic attenuated total reflection (ATR) sensor is introduced. The potential of this method was evaluated in vitro. This research presents a mid-infrared tunable laser with a broad emission spectrum band of 9.19 to 9.77[Formula: see text](1024~1088 cm(-1)) and proposes a method to control and stabilize the laser emission wavelength and power. Moreover, several fiber-optic ATR sensors were fabricated and investigated to determine glucose in combination with the tunable laser source, and the effective sensing optical length of these sensors was determined for the first time. In addition, the sensitivity of this system was four times that of a Fourier transform infrared (FT-IR) spectrometer. The noise-equivalent concentration (NEC) of this laser measurement system was as low as 3.8 mg/dL, which is among the most precise glucose measurements using mid-infrared spectroscopy. Furthermore, a partial least-squares regression and Clarke error grid were used to quantify the predictability and evaluate the prediction accuracy of glucose concentration in the range of 5 to 500 mg/dL (physiologically relevant range: 30~400 mg/dL). The experimental results were clinically acceptable. The high sensitivity, tunable laser source, low NEC and small fiber-optic ATR sensor demonstrate an encouraging step in the work towards precisely monitoring glucose levels in vivo.
Collapse
Affiliation(s)
- Songlin Yu
- State Key Laboratory of Precision Measuring Technology & Instruments, Tianjin University No. 92, Weijin Road, Nankai District, Tianjin 300072, China
| | - Dachao Li
- State Key Laboratory of Precision Measuring Technology & Instruments, Tianjin University No. 92, Weijin Road, Nankai District, Tianjin 300072, China
| | - Hao Chong
- State Key Laboratory of Precision Measuring Technology & Instruments, Tianjin University No. 92, Weijin Road, Nankai District, Tianjin 300072, China
| | - Changyue Sun
- Tianjin Key Laboratory of Biomedical Detecting Techniques & Instruments, Tianjin University, No. 92, Weijin Road, Nankai District, Tianjin 300072, China
| | - Haixia Yu
- Tianjin Key Laboratory of Biomedical Detecting Techniques & Instruments, Tianjin University, No. 92, Weijin Road, Nankai District, Tianjin 300072, China
| | - Kexin Xu
- State Key Laboratory of Precision Measuring Technology & Instruments, Tianjin University No. 92, Weijin Road, Nankai District, Tianjin 300072, China
| |
Collapse
|
10
|
Brandstetter M, Sumalowitsch T, Genner A, Posch AE, Herwig C, Drolz A, Fuhrmann V, Perkmann T, Lendl B. Reagent-free monitoring of multiple clinically relevant parameters in human blood plasma using a mid-infrared quantum cascade laser based sensor system. Analyst 2013; 138:4022-8. [DOI: 10.1039/c3an00300k] [Citation(s) in RCA: 45] [Impact Index Per Article: 4.1] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/21/2022]
|
11
|
Yang X, Zhang AY, Wheeler DA, Bond TC, Gu C, Li Y. Direct molecule-specific glucose detection by Raman spectroscopy based on photonic crystal fiber. Anal Bioanal Chem 2011; 402:687-91. [DOI: 10.1007/s00216-011-5575-1] [Citation(s) in RCA: 54] [Impact Index Per Article: 4.2] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/05/2011] [Revised: 11/10/2011] [Accepted: 11/11/2011] [Indexed: 11/30/2022]
|
12
|
Vrančić C, Fomichova A, Gretz N, Herrmann C, Neudecker S, Pucci A, Petrich W. Continuous glucose monitoring by means of mid-infrared transmission laser spectroscopy in vitro. Analyst 2011; 136:1192-8. [PMID: 21274463 DOI: 10.1039/c0an00537a] [Citation(s) in RCA: 39] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/21/2022]
Abstract
The continuous surveillance of glucose concentration reduces short-term risks and long-term complications for people with diabetes mellitus, a disorder of glucose metabolism. As a first step towards the continuous monitoring of glucose, reagent-free transmission spectroscopy in the mid-infrared region has been carried out in vitro using a quantum cascade laser and an optical silver halide fiber. A 30 μm gap in the fiber allowed for transmission spectroscopy of aqueous glucose solutions at a wavelength of 9.69 μm, which is specific to a molecular vibration of glucose. A noise-equivalent concentration as low as 4 mg/dL was achieved at an average power of 1.8 mW and an integration time of 50 s. This is among the most precise of glucose measurements using mid-infrared spectroscopy. Even with the very low average laser power of 0.07 mW the sensitivity of previous results (using a fiber optical evanescent field analysis) has been improved upon by almost one order of magnitude. Finally, the impact of potentially interfering substances such as other carbohydrates was analyzed.
Collapse
Affiliation(s)
- Christian Vrančić
- Kirchhoff Institute for Physics, University of Heidelberg, Im Neuenheimer Feld 227, 69120 Heidelberg, Germany
| | | | | | | | | | | | | |
Collapse
|
13
|
Gonzalvez A, Garrigues S, de la Guardia M, Armenta S. The ways to the trace level analysis in infrared spectroscopy. ANALYTICAL METHODS : ADVANCING METHODS AND APPLICATIONS 2011; 3:43-52. [PMID: 32938108 DOI: 10.1039/c0ay00437e] [Citation(s) in RCA: 15] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/11/2023]
Abstract
The future of infrared (IR) spectroscopy as an analytical technique is assured due to its versatility and its numerous advantages; such as the possibility to obtain molecular specific information for virtually any sample in any state with no treatment or minimal sample preparation. However, spectroscopists are not satisfied with relegating IR spectroscopy just to major and minor component analysis and have been looking at analysis at the trace level too. This review is the recognition of the brilliant research performed during the past two decades and the advances achieved in this area, which have made possible the analysis of contaminants at parts per billion (ppb) levels by IR in different matrices; such as water and soils.
Collapse
Affiliation(s)
- Ana Gonzalvez
- Analytical Chemistry Department, University of Valencia, 50th Dr Moliner Street, 46100, Burjassot, Spain.
| | - Salvador Garrigues
- Analytical Chemistry Department, University of Valencia, 50th Dr Moliner Street, 46100, Burjassot, Spain.
| | - Miguel de la Guardia
- Analytical Chemistry Department, University of Valencia, 50th Dr Moliner Street, 46100, Burjassot, Spain.
| | - Sergio Armenta
- Department of Chemistry, UniversitatAutonoma de Barcelona, EdificiCn, Bellatera 08192, Spain
| |
Collapse
|
14
|
Grills DC, Cook AR, Fujita E, George MW, Preses JM, Wishart JF. Application of external-cavity quantum cascade infrared lasers to nanosecond time-resolved infrared spectroscopy of condensed-phase samples following pulse radiolysis. APPLIED SPECTROSCOPY 2010; 64:563-570. [PMID: 20537222 DOI: 10.1366/000370210791414344] [Citation(s) in RCA: 14] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/29/2023]
Abstract
Pulse radiolysis, utilizing short pulses of high-energy electrons from accelerators, is a powerful method for rapidly generating reduced or oxidized species and other free radicals in solution. Combined with fast time-resolved spectroscopic detection (typically in the ultraviolet/visible/near-infrared), it is invaluable for monitoring the reactivity of species subjected to radiolysis on timescales ranging from picoseconds to seconds. However, it is often difficult to identify the transient intermediates definitively due to a lack of structural information in the spectral bands. Time-resolved vibrational spectroscopy offers the structural specificity necessary for mechanistic investigations but has received only limited application in pulse radiolysis experiments. For example, time-resolved infrared (TRIR) spectroscopy has only been applied to a handful of gas-phase studies, limited mainly by several technical challenges. We have exploited recent developments in commercial external-cavity quantum cascade laser (EC-QCL) technology to construct a nanosecond TRIR apparatus that has allowed, for the first time, TRIR spectra to be recorded following pulse radiolysis of condensed-phase samples. Near single-shot sensitivity of DeltaOD <1 x 10(-3) has been achieved, with a response time of <20 ns. Using two continuous-wave EC-QCLs, the current apparatus covers a probe region from 1890-2084 cm(-1), and TRIR spectra are acquired on a point-by-point basis by recording transient absorption decay traces at specific IR wavelengths and combining these to generate spectral time slices. The utility of the apparatus has been demonstrated by monitoring the formation and decay of the one-electron reduced form of the CO(2) reduction catalyst, [Re(I)(bpy)(CO)(3)(CH(3)CN)](+), in acetonitrile with nanosecond time resolution following pulse radiolysis. Characteristic red-shifting of the nu(CO) IR bands confirmed that one-electron reduction of the complex took place. The availability of TRIR detection with high sensitivity opens up a wide range of mechanistic pulse radiolysis investigations that were previously difficult or impossible to perform with transient UV/visible detection.
Collapse
Affiliation(s)
- David C Grills
- Chemistry Department, Brookhaven National Laboratory, Upton, New York 11973-5000, USA.
| | | | | | | | | | | |
Collapse
|
15
|
Affiliation(s)
- Otto S. Wolfbeis
- Institute of Analytical Chemistry, Chemo- and Biosensors, University of Regensburg, D-93040 Regensburg, Germany
| |
Collapse
|
16
|
Ellis DI, Dunn WB, Griffin JL, Allwood JW, Goodacre R. Metabolic fingerprinting as a diagnostic tool. Pharmacogenomics 2008; 8:1243-66. [PMID: 17924839 DOI: 10.2217/14622416.8.9.1243] [Citation(s) in RCA: 301] [Impact Index Per Article: 18.8] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/25/2022] Open
Abstract
Within the framework of systems biology, functional analyses at all 'omic levels have seen an intense level of activity during the first decade of the twenty-first century. These include genomics, transcriptomics, proteomics, metabolomics and lipidomics. It could be said that metabolomics offers some unique advantages over the other 'omics disciplines and one of the core approaches of metabolomics for disease diagnostics is metabolic fingerprinting. This review provides an overview of the main metabolic fingerprinting approaches used for disease diagnostics and includes: infrared and Raman spectroscopy, Nuclear magnetic resonance (NMR) spectroscopy, followed by an introduction to a wide range of novel mass spectrometry-based methods, which are currently under intense investigation and developmental activity in laboratories worldwide. It is hoped that this review will act as a springboard for researchers and clinicians across a wide range of disciplines in this exciting era of multidisciplinary and novel approaches to disease diagnostics.
Collapse
Affiliation(s)
- David I Ellis
- University of Manchester, School of Chemistry, Manchester Interdisciplinary Biocentre, 131 Princess Street, Manchester M1 7ND, UK.
| | | | | | | | | |
Collapse
|
17
|
Wang L, Mizaikoff B. Application of multivariate data-analysis techniques to biomedical diagnostics based on mid-infrared spectroscopy. Anal Bioanal Chem 2008; 391:1641-54. [PMID: 18379763 DOI: 10.1007/s00216-008-1989-9] [Citation(s) in RCA: 93] [Impact Index Per Article: 5.8] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/10/2008] [Revised: 02/14/2008] [Accepted: 02/18/2008] [Indexed: 10/22/2022]
Abstract
The objective of this contribution is to review the application of advanced multivariate data-analysis techniques in the field of mid-infrared (MIR) spectroscopic biomedical diagnosis. MIR spectroscopy is a powerful chemical analysis tool for detecting biomedically relevant constituents such as DNA/RNA, proteins, carbohydrates, lipids, etc., and even diseases or disease progression that may induce changes in the chemical composition or structure of biological systems including cells, tissues, and bio-fluids. However, MIR spectra of multiple constituents are usually characterized by strongly overlapping spectral features reflecting the complexity of biological samples. Consequently, MIR spectra of biological samples are frequently difficult to interpret by simple data-analysis techniques. Hence, with increasing complexity of the sample matrix more sophisticated mathematical and statistical data analysis routines are required for deconvoluting spectroscopic data and for providing useful results from information-rich spectroscopic signals. A large body of work relates to the combination of multivariate data-analysis techniques with MIR spectroscopy, and has been applied by a variety of research groups to biomedically relevant areas such as cancer detection and analysis, artery diseases, biomarkers, and other pathologies. The reported results indeed reveal a promising perspective for more widespread application of multivariate data analysis in assisting MIR spectroscopy as a screening or diagnostic tool in biomedical research and clinical studies. While the authors do not mean to ignore any relevant contributions to biomedical analysis across the entire electromagnetic spectrum, they confine the discussion in this contribution to the mid-infrared spectral range as a potentially very useful, yet underutilized frequency region. Selected representative examples without claiming completeness will demonstrate a range of biomedical diagnostic applications with particular emphasis on the advantageous interaction between multivariate data analysis and MIR spectroscopy.
Collapse
Affiliation(s)
- Liqun Wang
- School of Chemistry and Biochemistry, Georgia Institute of Technology, Atlanta, GA, 30332-0400, USA
| | | |
Collapse
|
18
|
Abstract
BACKGROUND Tight glycemic control (TGC) studies in intensive care units (ICU) have shown substantial improvements in clinical outcomes. However, implementation of TGC in ICU practice is partly constrained by the lack of automated continuous blood glucose monitoring systems that can facilitate clinically accurate feedback of glycemic data. The aim of this work is to develop a portable automated blood sampling system for integration with a glucose sensor for use in critical care settings. METHODS clinical prototypes for glucose sensing in blood were developed based on two distinct technologies: mid-infrared laser absorption spectroscopy and electrochemistry. Concurrently, an automated peripheral venous blood sampling system was developed for integration with the glucose sensing system. RESULTS The glucose sensing prototypes were validated clinically with various biological samples in a continuous mode. A customized micropump was employed in conjunction with a novel peripheral venous catheter system to automatically sample blood from the subject's forearm. Microvolumes of blood were sampled in continuous and intermittent modes at clinically relevant user-defined frequencies. The clinical feasibility of blood sampling, along with continuous glucose sensing, was demonstrated. CONCLUSION Cascade's automated peripheral venous blood sampling system, in combination with a flow-through glucose sensor system, offers several advantages over current state-of-the-art systems. This includes the potential for significantly improved workflow in the ICU, minimal discomfort to the patient, and accurate glucose measurement in whole blood, thus helping achieve tight glycemic control.
Collapse
|
19
|
Kondepati VR, Heise HM. Recent progress in analytical instrumentation for glycemic control in diabetic and critically ill patients. Anal Bioanal Chem 2007; 388:545-63. [PMID: 17431594 DOI: 10.1007/s00216-007-1229-8] [Citation(s) in RCA: 54] [Impact Index Per Article: 3.2] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/27/2006] [Revised: 02/16/2007] [Accepted: 02/22/2007] [Indexed: 01/08/2023]
Abstract
Implementing strict glycemic control can reduce the risk of serious complications in both diabetic and critically ill patients. For this reason, many different analytical, mainly electrochemical and optical sensor approaches for glucose measurements have been developed. Self-monitoring of blood glucose (SMBG) has been recognised as being an indispensable tool for intensive diabetes therapy. Recent progress in analytical instrumentation, allowing submicroliter samples of blood, alternative site testing, reduced test time, autocalibration, and improved precision, is comprehensively described in this review. Continuous blood glucose monitoring techniques and insulin infusion strategies, developmental steps towards the realization of the dream of an artificial pancreas under closed loop control, are presented. Progress in glucose sensing and glycemic control for both patient groups is discussed by assessing recent published literature (up to 2006). The state-of-the-art and trends in analytical techniques (either episodic, intermittent or continuous, minimal-invasive, or noninvasive) detailed in this review will provide researchers, health professionals and the diabetic community with a comprehensive overview of the potential of next-generation instrumentation suited to either short- and long-term implantation or ex vivo measurement in combination with appropriate body interfaces such as microdialysis catheters.
Collapse
Affiliation(s)
- Venkata Radhakrishna Kondepati
- ISAS--Institute for Analytical Sciences at the University of Dortmund, Bunsen-Kirchhoff-Strasse 11, 44139, Dortmund, Germany
| | | |
Collapse
|
20
|
Heise HM, Damm U, Bodenlenz M, Kondepati VR, Köhler G, Ellmerer M. Bedside monitoring of subcutaneous interstitial glucose in healthy individuals using microdialysis and infrared spectrometry. JOURNAL OF BIOMEDICAL OPTICS 2007; 12:024004. [PMID: 17477719 DOI: 10.1117/1.2714907] [Citation(s) in RCA: 13] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/15/2023]
Abstract
An IR-spectroscopy-based bedside device, coupled to a subcutaneously implanted microdialysis probe, is developed for quasicontinuous glucose monitoring with intermittent readouts at 10-min intervals, avoiding any sensor recalibration under long-term operation. The simultaneous estimation of the microdialysis recovery rate is possible using an acetate containing perfusate and determining its losses across the dialysis membrane. Measurements are carried out on four subjects, with experiments lasting either 8 or 28 h, respectively. Using the spectral interval data either from 1180 to 950 or 1560 to 1000 cm(-1), standard errors of prediction (SEPs) between 0.13 and 0.28 mM are achieved using multivariate calibration with partial least-squares (PLS) or classical least-squares (CLS) calibration models, respectively. The transfer of a PLS calibration model using the spectral and reference concentration data of the dialysates from the three 8-h-long experiments to a 28-h monitoring episode with another healthy subject is tested. Including microdialysis recovery for the determination of the interstitial glucose concentrations, an SEP of 0.24 mM is obtained versus whole blood glucose values. The option to determine other metabolites such as urea or lactate offers the possibility to develop a calibration- and reagent-free point-of-care analyzer.
Collapse
Affiliation(s)
- H Michael Heise
- ISAS-Institute for Analytical Sciences at the University of Dortmund, Bunsen-Kirchhoff-Str. 11, D-44139 Dortmund, Germany.
| | | | | | | | | | | |
Collapse
|