1
|
Mukherjee S, Bhaduri S, Harwood R, Murray P, Wilm B, Bearon R, Poptani H. Multiparametric MRI based assessment of kidney injury in a mouse model of ischemia reperfusion injury. Sci Rep 2024; 14:19922. [PMID: 39198525 PMCID: PMC11358484 DOI: 10.1038/s41598-024-70401-x] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/29/2024] [Accepted: 08/16/2024] [Indexed: 09/01/2024] Open
Abstract
Kidney diseases pose a global healthcare burden, with millions requiring renal replacement therapy. Ischemia/reperfusion injury (IRI) is a common pathology of acute kidney injury, causing hypoxia and subsequent inflammation-induced kidney damage. Accurate detection of acute kidney injury due to IRI is crucial for timely intervention. We used longitudinal, multi-parametric magnetic resonance imaging (MRI) employing arterial spin labelling (ASL), diffusion weighted imaging (DWI), and dynamic contrast enhanced (DCE)-MRI to assess IRI induced changes in both the injured and healthy contralateral kidney, in a unilateral IRI mouse model (n = 9). Multi-parametric MRI demonstrated significant differences in kidney volume (p = 0.001), blood flow (p = 0.002), filtration coefficient (p = 0.038), glomerular filtration rate (p = 0.005) and apparent diffusion coefficient (p = 0.048) between the injured kidney and contralateral kidney on day 1 post-IRI surgery. Identification of the injured kidney using principal component analysis including most of the imaging parameters demonstrated an area under the curve (AUC) of 0.97. These results point to the utility of multi-parametric MRI in early detection of IRI-induced kidney damage suggesting that the combination of various MRI parameters may be suitable for monitoring the extent of injury in this model.
Collapse
Affiliation(s)
- Soham Mukherjee
- Centre for Pre-Clinical Imaging, Molecular and Integrative Biology, Institute of Systems, University of Liverpool, Crown Street, Liverpool, L69 3BX, UK
| | - Sourav Bhaduri
- Centre for Pre-Clinical Imaging, Molecular and Integrative Biology, Institute of Systems, University of Liverpool, Crown Street, Liverpool, L69 3BX, UK
- Institute for Advancing Intelligence (IAI), TCG CREST, Kolkata, India
| | - Rachel Harwood
- Department of Women's and Children's Health, Institute of Life Course and Medical Sciences, University of Liverpool, Liverpool, UK
| | - Patricia Murray
- Department of Women's and Children's Health, Institute of Life Course and Medical Sciences, University of Liverpool, Liverpool, UK
| | - Bettina Wilm
- Department of Women's and Children's Health, Institute of Life Course and Medical Sciences, University of Liverpool, Liverpool, UK
| | - Rachel Bearon
- Department of Mathematical Science, University of Liverpool, Liverpool, UK
- Department of Mathematics, Kings College, London, UK
| | - Harish Poptani
- Centre for Pre-Clinical Imaging, Molecular and Integrative Biology, Institute of Systems, University of Liverpool, Crown Street, Liverpool, L69 3BX, UK.
| |
Collapse
|
2
|
Selby NM, Francis ST. Assessment of Acute Kidney Injury using MRI. J Magn Reson Imaging 2024. [PMID: 38334370 DOI: 10.1002/jmri.29281] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/30/2023] [Revised: 01/19/2024] [Accepted: 01/23/2024] [Indexed: 02/10/2024] Open
Abstract
There has been growing interest in using quantitative magnetic resonance imaging (MRI) to describe and understand the pathophysiology of acute kidney injury (AKI). The ability to assess kidney blood flow, perfusion, oxygenation, and changes in tissue microstructure at repeated timepoints is hugely appealing, as this offers new possibilities to describe nature and severity of AKI, track the time-course to recovery or progression to chronic kidney disease (CKD), and may ultimately provide a method to noninvasively assess response to new therapies. This could have significant clinical implications considering that AKI is common (affecting more than 13 million people globally every year), harmful (associated with short and long-term morbidity and mortality), and currently lacks specific treatments. However, this is also a challenging area to study. After the kidney has been affected by an initial insult that leads to AKI, complex coexisting processes ensue, which may recover or can progress to CKD. There are various preclinical models of AKI (from which most of our current understanding derives), and these differ from each other but more importantly from clinical AKI. These aspects are fundamental to interpreting the results of the different AKI studies in which renal MRI has been used, which encompass different settings of AKI and a variety of MRI measures acquired at different timepoints. This review aims to provide a comprehensive description and interpretation of current studies (both preclinical and clinical) in which MRI has been used to assess AKI, and discuss future directions in the field. LEVEL OF EVIDENCE: 1 TECHNICAL EFFICACY: Stage 3.
Collapse
Affiliation(s)
- Nicholas M Selby
- Centre for Kidney Research and Innovation, Academic Unit for Translational Medical Sciences, School of Medicine, University of Nottingham, Nottingham, UK
- Department of Renal Medicine, University Hospitals of Derby and Burton NHS Foundation Trust, Derby, UK
| | - Susan T Francis
- Sir Peter Mansfield Imaging Centre, School of Physics and Astronomy, University of Nottingham, Nottingham, UK
- NIHR Nottingham Biomedical Research Centre, Nottingham University Hospitals NHS Trust and The University of Nottingham, Nottingham, UK
| |
Collapse
|
3
|
Grashei M, Wodtke P, Skinner JG, Sühnel S, Setzer N, Metzler T, Gulde S, Park M, Witt D, Mohr H, Hundshammer C, Strittmatter N, Pellegata NS, Steiger K, Schilling F. Simultaneous magnetic resonance imaging of pH, perfusion and renal filtration using hyperpolarized 13C-labelled Z-OMPD. Nat Commun 2023; 14:5060. [PMID: 37604826 PMCID: PMC10442412 DOI: 10.1038/s41467-023-40747-3] [Citation(s) in RCA: 8] [Impact Index Per Article: 8.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/22/2022] [Accepted: 08/09/2023] [Indexed: 08/23/2023] Open
Abstract
pH alterations are a hallmark of many pathologies including cancer and kidney disease. Here, we introduce [1,5-13C2]Z-OMPD as a hyperpolarized extracellular pH and perfusion sensor for MRI which allows to generate a multiparametric fingerprint of renal disease status and to detect local tumor acidification. Exceptional long T1 of two minutes at 1 T, high pH sensitivity of up to 1.9 ppm per pH unit and suitability of using the C1-label as internal frequency reference enables pH imaging in vivo of three pH compartments in healthy rat kidneys. Spectrally selective targeting of both 13C-resonances enables simultaneous imaging of perfusion and filtration in 3D and pH in 2D within one minute to quantify renal blood flow, glomerular filtration rates and renal pH in healthy and hydronephrotic kidneys with superior sensitivity compared to clinical routine methods. Imaging multiple biomarkers within a single session renders [1,5-13C2]Z-OMPD a promising new hyperpolarized agent for oncology and nephrology.
Collapse
Affiliation(s)
- Martin Grashei
- Department of Nuclear Medicine, TUM School of Medicine, Klinikum rechts der Isar, Technical University of Munich, D-81675, Munich, Germany
| | - Pascal Wodtke
- Department of Nuclear Medicine, TUM School of Medicine, Klinikum rechts der Isar, Technical University of Munich, D-81675, Munich, Germany
| | - Jason G Skinner
- Department of Nuclear Medicine, TUM School of Medicine, Klinikum rechts der Isar, Technical University of Munich, D-81675, Munich, Germany
| | - Sandra Sühnel
- Department of Nuclear Medicine, TUM School of Medicine, Klinikum rechts der Isar, Technical University of Munich, D-81675, Munich, Germany
| | - Nadine Setzer
- Department of Nuclear Medicine, TUM School of Medicine, Klinikum rechts der Isar, Technical University of Munich, D-81675, Munich, Germany
| | - Thomas Metzler
- Comparative Experimental Pathology (CEP), Institute of Pathology, School of Medicine, Technical University of Munich, D-81675, Munich, Germany
| | - Sebastian Gulde
- Institute for Diabetes and Cancer, Helmholtz Zentrum München, D-85764, Neuherberg, Germany
| | - Mihyun Park
- Department of Biosciences, TUM School of Natural Sciences, Technical University of Munich, D-85748, Garching, Germany
| | - Daniela Witt
- Department of Biosciences, TUM School of Natural Sciences, Technical University of Munich, D-85748, Garching, Germany
| | - Hermine Mohr
- Institute for Diabetes and Cancer, Helmholtz Zentrum München, D-85764, Neuherberg, Germany
| | - Christian Hundshammer
- Department of Nuclear Medicine, TUM School of Medicine, Klinikum rechts der Isar, Technical University of Munich, D-81675, Munich, Germany
| | - Nicole Strittmatter
- Department of Biosciences, TUM School of Natural Sciences, Technical University of Munich, D-85748, Garching, Germany
| | - Natalia S Pellegata
- Institute for Diabetes and Cancer, Helmholtz Zentrum München, D-85764, Neuherberg, Germany
- Department of Biology and Biotechnology, University of Pavia, I-27100, Pavia, Italy
| | - Katja Steiger
- Comparative Experimental Pathology (CEP), Institute of Pathology, School of Medicine, Technical University of Munich, D-81675, Munich, Germany
| | - Franz Schilling
- Department of Nuclear Medicine, TUM School of Medicine, Klinikum rechts der Isar, Technical University of Munich, D-81675, Munich, Germany.
- Munich Institute of Biomedical Engineering, Technical University of Munich, D-85748, Garching, Germany.
- German Cancer Consortium (DKTK), Partner Site Munich and German Cancer Research Center (DKFZ), D-69120, Heidelberg, Germany.
| |
Collapse
|
4
|
Rasmussen CW, Bøgh N, Bech SK, Thorsen TH, Hansen ESS, Bertelsen LB, Laustsen C. Fibrosis imaging with multiparametric proton and sodium MRI in pig injury models. NMR IN BIOMEDICINE 2023; 36:e4838. [PMID: 36151711 PMCID: PMC10078455 DOI: 10.1002/nbm.4838] [Citation(s) in RCA: 6] [Impact Index Per Article: 6.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 03/14/2022] [Revised: 09/10/2022] [Accepted: 09/12/2022] [Indexed: 05/10/2023]
Abstract
Chronic kidney disease (CKD) is common and has huge implications for health and mortality. It is aggravated by intrarenal fibrosis, but the assessment of fibrosis is limited to kidney biopsies, which carry a risk of complications and sampling errors. This calls for a noninvasive modality for diagnosing and staging intrarenal fibrosis. The current, exploratory study evaluates a multiparametric MRI protocol including sodium imaging (23 Na-MRI) to determine the opportunities within this modality to assess kidney injury as a surrogate endpoint of fibrosis. The study includes 43 pigs exposed to ischemia-reperfusion injury (IRI) or unilateral ureteral obstruction (UUO), or serving as healthy controls. Fibrosis was determined using gene expression analysis of collagen. The medulla/cortex ratio of 23 Na-MRI decreased in the injured kidney in the IRI pigs, but not in the UUO pigs (p = 0.0180, p = 0.0754). To assess the combination of MRI parameters in estimating fibrosis, we created a linear regression model consisting of the cortical apparent diffusion coefficient, ΔR2*, ΔT1, the 23 Na medulla/cortex ratio, and plasma creatinine (R2 = 0.8009, p = 0.0117). The 23 Na medulla/cortex ratio only slightly improved the fibrosis prediction model, leaving 23 Na-MRI in an ambiguous place for evaluation of intrarenal fibrosis. Use of multiparametric MRI in combination with plasma creatinine shows potential for the estimation of fibrosis in human kidney disease, but more translational and clinical work is warranted before MRI can contribute to earlier diagnosis and evaluation of treatment for acute kidney injury and CKD.
Collapse
Affiliation(s)
- Camilla W. Rasmussen
- The MR Research Center, Department of Clinical MedicineAarhus UniversityAarhusDenmark
| | - Nikolaj Bøgh
- The MR Research Center, Department of Clinical MedicineAarhus UniversityAarhusDenmark
| | - Sabrina K. Bech
- The MR Research Center, Department of Clinical MedicineAarhus UniversityAarhusDenmark
| | - Thomas H. Thorsen
- The MR Research Center, Department of Clinical MedicineAarhus UniversityAarhusDenmark
| | - Esben S. S. Hansen
- The MR Research Center, Department of Clinical MedicineAarhus UniversityAarhusDenmark
| | - Lotte B. Bertelsen
- The MR Research Center, Department of Clinical MedicineAarhus UniversityAarhusDenmark
| | - Christoffer Laustsen
- The MR Research Center, Department of Clinical MedicineAarhus UniversityAarhusDenmark
| |
Collapse
|
5
|
Tao Q, Zhang D, Zhang Q, Liu C, Ye S, Feng Y, Liu R. Mitochondrial targeted ROS Scavenger based on nitroxide for Treatment and MRI imaging of Acute Kidney Injury. Free Radic Res 2022; 56:303-315. [PMID: 35746859 DOI: 10.1080/10715762.2022.2093724] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/04/2022]
Abstract
INTRODUCTION Overproduction of reactive oxygen species (ROS) during oxidative stress is a hallmark of acute kidney injure (AKI), which induced the damage to the renal cells and mitochondrial injury. PURPOSE In this contribution, we prepared mitochondrial targeted nitroxide, which linked 3-carboxy-2,2,5,5-tetramethylpyrrolidine 1-oxyl (carboxy-PROXYL) with (2-aminoethyl)triphenylphosphonium bromide (TPP), named TPP-PROXYL to eliminate the ROS in situ and image the oxidative stress reaction by MRI. METHODS 2,7-Dichlorodihydrofluorescein diacetate (DCFH-DA) staining, mitochondrial membrane potential assay (JC-1) staining and transmission electron microscope (TEM) experiments were processed to verify that TPP-PROXYL could target mitochondria, scavenge the ROS, and prevent damage to mitochondria in live cells. Contrast enhanced MRI also been used to monitor these redox reaction in AKI model. RESULTS TPP-PROXYL demonstrated excellent ROS T1-weighted magnetic resonance imaging (MRI) enhancement in vitro and in vivo, with r1 value about 0.190 mM-1·s-1. In vivo AKI treatment experiments proved that TPP-PROXYL could improve the survival rate of mice and inhibit kidney damage. Moreover, the great ROS scavenging capability and the renal damage reduction during AKI treatment of TPP-PROXYL was verified via MR imaging technology. CONCLUSION Collectively, this research provides TPP-PROXYL would serve as a powerful platform to realize ROS scavenging, treatment and MR imaging of AKI.
Collapse
Affiliation(s)
- Quan Tao
- School of Biomedical Engineering, Southern Medical University, Guangzhou, China.,Guangdong Provincial Key Laboratory of Medical Image Processing, Southern Medical University, Guangzhou, China.,Guangdong Province Engineering Laboratory for Medical Imaging and Diagnostic Technology, Southern Medical University, Guangzhou, China.,Key Laboratory of Mental Health of the Ministry of Education & Guangdong-Hong Kong-Macao Greater Bay Area Center for Brain Science and Brain-Inspired Intelligence, Southern Medical University, Guangzhou, China
| | - Di Zhang
- School of Biomedical Engineering, Southern Medical University, Guangzhou, China.,Guangdong Provincial Key Laboratory of Medical Image Processing, Southern Medical University, Guangzhou, China.,Guangdong Province Engineering Laboratory for Medical Imaging and Diagnostic Technology, Southern Medical University, Guangzhou, China.,Key Laboratory of Mental Health of the Ministry of Education & Guangdong-Hong Kong-Macao Greater Bay Area Center for Brain Science and Brain-Inspired Intelligence, Southern Medical University, Guangzhou, China
| | - Qianqian Zhang
- School of Biomedical Engineering, Southern Medical University, Guangzhou, China.,Guangdong Provincial Key Laboratory of Medical Image Processing, Southern Medical University, Guangzhou, China.,Guangdong Province Engineering Laboratory for Medical Imaging and Diagnostic Technology, Southern Medical University, Guangzhou, China.,Key Laboratory of Mental Health of the Ministry of Education & Guangdong-Hong Kong-Macao Greater Bay Area Center for Brain Science and Brain-Inspired Intelligence, Southern Medical University, Guangzhou, China
| | - Chuang Liu
- School of Biomedical Engineering, Southern Medical University, Guangzhou, China.,Guangdong Provincial Key Laboratory of Medical Image Processing, Southern Medical University, Guangzhou, China.,Guangdong Province Engineering Laboratory for Medical Imaging and Diagnostic Technology, Southern Medical University, Guangzhou, China.,Key Laboratory of Mental Health of the Ministry of Education & Guangdong-Hong Kong-Macao Greater Bay Area Center for Brain Science and Brain-Inspired Intelligence, Southern Medical University, Guangzhou, China
| | - Sheng Ye
- School of Biomedical Engineering, Southern Medical University, Guangzhou, China.,Guangdong Provincial Key Laboratory of Medical Image Processing, Southern Medical University, Guangzhou, China.,Guangdong Province Engineering Laboratory for Medical Imaging and Diagnostic Technology, Southern Medical University, Guangzhou, China.,Key Laboratory of Mental Health of the Ministry of Education & Guangdong-Hong Kong-Macao Greater Bay Area Center for Brain Science and Brain-Inspired Intelligence, Southern Medical University, Guangzhou, China
| | - Yanqiu Feng
- School of Biomedical Engineering, Southern Medical University, Guangzhou, China.,Guangdong Provincial Key Laboratory of Medical Image Processing, Southern Medical University, Guangzhou, China.,Guangdong Province Engineering Laboratory for Medical Imaging and Diagnostic Technology, Southern Medical University, Guangzhou, China.,Key Laboratory of Mental Health of the Ministry of Education & Guangdong-Hong Kong-Macao Greater Bay Area Center for Brain Science and Brain-Inspired Intelligence, Southern Medical University, Guangzhou, China
| | - Ruiyuan Liu
- School of Biomedical Engineering, Southern Medical University, Guangzhou, China.,Guangdong Provincial Key Laboratory of Medical Image Processing, Southern Medical University, Guangzhou, China.,Guangdong Province Engineering Laboratory for Medical Imaging and Diagnostic Technology, Southern Medical University, Guangzhou, China.,Key Laboratory of Mental Health of the Ministry of Education & Guangdong-Hong Kong-Macao Greater Bay Area Center for Brain Science and Brain-Inspired Intelligence, Southern Medical University, Guangzhou, China
| |
Collapse
|
6
|
Comparison of multiparametric magnetic resonance imaging sequences with laboratory parameters for prognosticating renal function in chronic kidney disease. Sci Rep 2021; 11:22129. [PMID: 34764322 PMCID: PMC8586015 DOI: 10.1038/s41598-021-01147-z] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/05/2021] [Accepted: 10/11/2021] [Indexed: 11/12/2022] Open
Abstract
Magnetic resonance imaging (MRI) is playing an increasingly important role in evaluating chronic kidney disease (CKD). It has the potential to be used not only for evaluation of physiological and pathological states, but also for prediction of disease course. Although different MRI sequences have been employed in renal disease, there are few studies that have compared the different sequences. We compared several multiparametric MRI sequences, and compared their results with the estimated glomerular filtration rate. Principal component analysis showed a similarity between T1 values and tissue perfusion (arterial spin labelling), and between fractional anisotropy (diffusion tensor imaging) and apparent diffusion coefficient values (diffusion-weighted imaging). In multiple regression analysis, only T2* values, derived from the blood oxygenation level-dependent (BOLD) MRI sequence, were associated with estimated glomerular filtration rate slope after adjusting for degree of proteinuria, a classic prognostic factor for CKD. In receiver operating characteristic curve analysis, T2* values were a good predictor of rapid deterioration, regardless of the degree of proteinuria. This suggests further study of the use of BOLD-derived T2* values in the workup of CKD, especially to predict the disease course.
Collapse
|
7
|
Zhao F, Zhou X, Messina E, Hu L, Holahan MA, Swaminath G, Hines CDG. Robust arterial spin labeling MRI measurement of pharmacologically induced perfusion change in rat kidneys. NMR IN BIOMEDICINE 2021; 34:e4566. [PMID: 34096123 DOI: 10.1002/nbm.4566] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 12/21/2020] [Revised: 04/29/2021] [Accepted: 05/12/2021] [Indexed: 06/12/2023]
Abstract
Kidney diseases such as acute kidney injury, diabetic nephropathy and chronic kidney disease (CKD) are related to dysfunctions of the microvasculature in the kidney causing a decrease in renal blood perfusion (RBP). Pharmacological intervention to improve the function of the microvasculature is a viable strategy for the potential treatment of these diseases. The measurement of RBP is a reliable biomarker to evaluate the efficacy of pharmacological agents' actions on the microvasculature, and measurement of RBP responses to different pharmacological agents can also help elucidate the mechanism of hemodynamic regulation in the kidney. Magnetic resonance imaging (MRI) with flow-sensitive alternating inversion recovery (FAIR) arterial spin labeling (ASL) has been used to measure RBP in humans and animals. However, artifacts caused by respiratory and peristaltic motions limit the potential of FAIR ASL in drug discovery and kidney research. In this study, the combined anesthesia protocol of inactin with a low dose of isoflurane was used to fully suppress peristalsis in rats, which were ventilated with an MRI-synchronized ventilator. FAIR ASL data were acquired in eight axial slices using a single-shot, gradient-echo, echo-planar imaging (EPI) sequence. The artifacts in the FAIR ASL RBP measurement due to respiratory and peristaltic motions were substantially eliminated. The RBP responses to fenoldopam and L-NAME were measured, and the increase and decrease in RBP caused by fenoldopam and L-NAME, respectively, were robustly observed. To further validate FAIR ASL, the renal blood flow (RBF) responses to the same agents were measured by an invasive perivascular flow probe method. The pharmacological agent-induced responses in RBP and RBF are similar. This indicates that FAIR ASL has the sensitivity to measure pharmacologically induced changes in RBP. FAIR ASL with multislice EPI can be a valuable tool for supporting drug discovery, and for elucidating the mechanism of hemodynamic regulation in kidneys.
Collapse
Affiliation(s)
| | | | | | - Lufei Hu
- Merck & Co. Inc., Kenilworth, New Jersey, USA
| | | | | | | |
Collapse
|
8
|
Alhummiany BA, Shelley D, Saysell M, Olaru MA, Kühn B, Buckley DL, Bailey J, Wroe K, Coupland C, Mansfield MW, Sourbron SP, Sharma K. Bias and Precision in Magnetic Resonance Imaging-Based Estimates of Renal Blood Flow: Assessment by Triangulation. J Magn Reson Imaging 2021; 55:1241-1250. [PMID: 34397124 DOI: 10.1002/jmri.27888] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/12/2021] [Revised: 07/31/2021] [Accepted: 08/03/2021] [Indexed: 12/26/2022] Open
Abstract
BACKGROUND Renal blood flow (RBF) can be measured with dynamic contrast enhanced-MRI (DCE-MRI) and arterial spin labeling (ASL). Unfortunately, individual estimates from both methods vary and reference-standard methods are not available. A potential solution is to include a third, arbitrating MRI method in the comparison. PURPOSE To compare RBF estimates between ASL, DCE, and phase contrast (PC)-MRI. STUDY TYPE Prospective. POPULATION Twenty-five patients with type-2 diabetes (36% female) and five healthy volunteers (HV, 80% female). FIELD STRENGTH/SEQUENCES A 3 T; gradient-echo 2D-DCE, pseudo-continuous ASL (pCASL) and cine 2D-PC. ASSESSMENT ASL, DCE, and PC were acquired once in all patients. ASL and PC were acquired four times in each HV. RBF was estimated and split-RBF was derived as (right kidney RBF)/total RBF. Repeatability error (RE) was calculated for each HV, RE = 1.96 × SD, where SD is the standard deviation of repeat scans. STATISTICAL TESTS Paired t-tests and one-way analysis of variance (ANOVA) were used for statistical analysis. The 95% confidence interval (CI) for difference between ASL/PC and DCE/PC was assessed using two-sample F-test for variances. Statistical significance level was P < 0.05. Influential outliers were assessed with Cook's distance (Di > 1) and results with outliers removed were presented. RESULTS In patients, the mean RBF (mL/min/1.73m2 ) was 618 ± 62 (PC), 526 ± 91 (ASL), and 569 ± 110 (DCE). Differences between measurements were not significant (P = 0.28). Intrasubject agreement was poor for RBF with limits-of-agreement (mL/min/1.73m2 ) [-687, 772] DCE-ASL, [-482, 580] PC-DCE, and [-277, 460] PC-ASL. The difference PC-ASL was significantly smaller than PC-DCE, but this was driven by a single-DCE outlier (P = 0.31, after removing outlier). The difference in split-RBF was comparatively small. In HVs, mean RE (±95% CI; mL/min/1.73 m2 ) was significantly smaller for PC (79 ± 41) than for ASL (241 ± 85). CONCLUSIONS ASL, DCE, and PC RBF show poor agreement in individual subjects but agree well on average. Triangulation with PC suggests that the accuracy of ASL and DCE is comparable. EVIDENCE LEVEL 2 TECHNICAL EFFICACY: Stage 2.
Collapse
Affiliation(s)
| | - David Shelley
- Department of Biomedical Imaging Sciences, University of Leeds, Leeds, UK.,Leeds Teaching Hospitals NHS Trust, Leeds, UK
| | - Margaret Saysell
- Department of Biomedical Imaging Sciences, University of Leeds, Leeds, UK.,Leeds Teaching Hospitals NHS Trust, Leeds, UK
| | | | - Bernd Kühn
- Siemens Healthcare GmbH, Erlangen, Germany
| | - David L Buckley
- Department of Biomedical Imaging Sciences, University of Leeds, Leeds, UK
| | | | - Kelly Wroe
- Leeds Teaching Hospitals NHS Trust, Leeds, UK
| | | | | | - Steven P Sourbron
- Department of Imaging, Infection, Immunity and Cardiovascular Disease, The University of Sheffield, Sheffield, UK
| | - Kanishka Sharma
- Department of Imaging, Infection, Immunity and Cardiovascular Disease, The University of Sheffield, Sheffield, UK
| |
Collapse
|
9
|
Lin L, Zhou X, Dekkers IA, Lamb HJ. Cardiorenal Syndrome: Emerging Role of Medical Imaging for Clinical Diagnosis and Management. J Pers Med 2021; 11:734. [PMID: 34442378 PMCID: PMC8400880 DOI: 10.3390/jpm11080734] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/27/2021] [Revised: 07/24/2021] [Accepted: 07/24/2021] [Indexed: 12/16/2022] Open
Abstract
Cardiorenal syndrome (CRS) concerns the interconnection between heart and kidneys in which the dysfunction of one organ leads to abnormalities of the other. The main clinical challenges associated with cardiorenal syndrome are the lack of tools for early diagnosis, prognosis, and evaluation of therapeutic effects. Ultrasound, computed tomography, nuclear medicine, and magnetic resonance imaging are increasingly used for clinical management of cardiovascular and renal diseases. In the last decade, rapid development of imaging techniques provides a number of promising biomarkers for functional evaluation and tissue characterization. This review summarizes the applicability as well as the future technological potential of each imaging modality in the assessment of CRS. Furthermore, opportunities for a comprehensive imaging approach for the evaluation of CRS are defined.
Collapse
Affiliation(s)
- Ling Lin
- Cardiovascular Imaging Group (CVIG), Department of Radiology, Leiden University Medical Center, 2333 ZA Leiden, The Netherlands; (L.L.); (I.A.D.); (H.J.L.)
| | - Xuhui Zhou
- Department of Radiology, The Eighth Affiliated Hospital of Sun Yat-sen University, Shenzhen 510833, China
| | - Ilona A. Dekkers
- Cardiovascular Imaging Group (CVIG), Department of Radiology, Leiden University Medical Center, 2333 ZA Leiden, The Netherlands; (L.L.); (I.A.D.); (H.J.L.)
| | - Hildo J. Lamb
- Cardiovascular Imaging Group (CVIG), Department of Radiology, Leiden University Medical Center, 2333 ZA Leiden, The Netherlands; (L.L.); (I.A.D.); (H.J.L.)
| |
Collapse
|
10
|
Iñigo-Marco I, Istúriz J, Fernández M, Nicolas MJ, Domínguez P, Bastarrika G, Valencia M, Fernández-Seara MA. Imaging of Stroke in Rodents Using a Clinical Scanner and Inductively Coupled Specially Designed Receiver Coils. Ann Biomed Eng 2021; 49:746-756. [PMID: 32918104 DOI: 10.1007/s10439-020-02610-0] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/06/2020] [Accepted: 09/02/2020] [Indexed: 11/26/2022]
Abstract
Imaging of small laboratory animals in clinical MRI scanners is feasible but challenging. Compared with dedicated preclinical systems, clinical scanners have relatively low B0 field (1.5-3.0 T) and gradient strength (40-60 mT/m). This work explored the use of wireless inductively coupled coils (ICCs) combined with appropriate pulse sequence parameters to overcome these two drawbacks, with a special emphasis on the optimization of the coil passive detuning circuit for this application. A Bengal rose photothrombotic stroke model was used to induce cortical infarction in rats and mice. Animals were imaged in a 3T scanner using T2 and T1-weighted sequences. In all animals, the ICCs allowed acquisition of high-quality images of the infarcted brain at acute and chronic stages. Images obtained with the ICCs showed a substantial increase in SNR compared to clinical coils (by factors of 6 in the rat brain and 16-17 in the mouse brain), and the absence of wires made the animal preparation workflow straightforward.
Collapse
Affiliation(s)
- Ignacio Iñigo-Marco
- Neuroscience Program, CIMA, University of Navarra, Pamplona, Spain
- IdiSNA, Navarra Institute for Health Research, Pamplona, Spain
| | | | - Miguel Fernández
- Radiology Department, Clínica Universidad de Navarra, Pio XII, 36, 31008, Pamplona, Spain
| | - Maria J Nicolas
- Neuroscience Program, CIMA, University of Navarra, Pamplona, Spain
- IdiSNA, Navarra Institute for Health Research, Pamplona, Spain
| | - Pablo Domínguez
- IdiSNA, Navarra Institute for Health Research, Pamplona, Spain
- Radiology Department, Clínica Universidad de Navarra, Pio XII, 36, 31008, Pamplona, Spain
| | - Gorka Bastarrika
- IdiSNA, Navarra Institute for Health Research, Pamplona, Spain
- Radiology Department, Clínica Universidad de Navarra, Pio XII, 36, 31008, Pamplona, Spain
| | - Miguel Valencia
- Neuroscience Program, CIMA, University of Navarra, Pamplona, Spain
- IdiSNA, Navarra Institute for Health Research, Pamplona, Spain
| | - María A Fernández-Seara
- IdiSNA, Navarra Institute for Health Research, Pamplona, Spain.
- Radiology Department, Clínica Universidad de Navarra, Pio XII, 36, 31008, Pamplona, Spain.
| |
Collapse
|
11
|
Longo DL, Irrera P, Consolino L, Sun PZ, McMahon MT. Renal pH Imaging Using Chemical Exchange Saturation Transfer (CEST) MRI: Basic Concept. Methods Mol Biol 2021; 2216:241-256. [PMID: 33476004 DOI: 10.1007/978-1-0716-0978-1_14] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 04/19/2023]
Abstract
Magnetic Resonance Imaging (MRI) has been actively explored in the last several decades for assessing renal function by providing several physiological information, including glomerular filtration rate, renal plasma flow, tissue oxygenation and water diffusion. Within MRI, the developing field of chemical exchange saturation transfer (CEST) has potential to provide further functional information for diagnosing kidney diseases. Both endogenous produced molecules as well as exogenously administered CEST agents have been exploited for providing functional information related to kidney diseases in preclinical studies. In particular, CEST MRI has been exploited for assessing the acid-base homeostasis in the kidney and for monitoring pH changes in several disease models. This review summarizes several CEST MRI procedures for assessing kidney functionality and pH, for monitoring renal pH changes in different kidney injury models and for evaluating renal allograft rejection.This chapter is based upon work from the COST Action PARENCHIMA, a community-driven network funded by the European Cooperation in Science and Technology (COST) program of the European Union, which aims to improve the reproducibility and standardization of renal MRI biomarkers. This introduction chapter is complemented by two separate chapters describing the experimental procedure and data analysis.
Collapse
Affiliation(s)
- Dario Livio Longo
- Institute of Biostructures and Bioimaging (IBB), Italian National Research Council (CNR), Torino, Italy.
| | - Pietro Irrera
- University of Campania "Luigi Vanvitelli", Napoli, Italy
| | - Lorena Consolino
- Department of Molecular Biotechnology and Health Sciences, University of Torino, Torino, Italy
| | - Phillip Zhe Sun
- Yerkes Imaging Center, Yerkes National Primate Research Center, Emory University, Atlanta, GA, USA
- Department of Radiology and Imaging Sciences, Emory University School of Medicine, Atlanta, GA, USA
- Athinoula A. Martinos Center for Biomedical Imaging, Department of Radiology, Massachusetts General Hospital and Harvard Medical School, Charlestown, MA, USA
| | - Michael T McMahon
- F.M. Kirby Research Center for Functional Brain Imaging, Kennedy Krieger Institute, Baltimore, MD, USA
- Division of MR Research, The Russell H. Morgan Department of Radiology and Radiological Science, The Johns Hopkins University School of Medicine, Baltimore, MD, USA
| |
Collapse
|
12
|
Ku MC, Fernández-Seara MA, Kober F, Niendorf T. Noninvasive Renal Perfusion Measurement Using Arterial Spin Labeling (ASL) MRI: Basic Concept. Methods Mol Biol 2021; 2216:229-239. [PMID: 33476003 PMCID: PMC9703206 DOI: 10.1007/978-1-0716-0978-1_13] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 06/12/2023]
Abstract
The kidney is a complex organ involved in the excretion of metabolic products as well as the regulation of body fluids, osmolarity, and homeostatic status. These functions are influenced in large part by alterations in the regional distribution of blood flow between the renal cortex and medulla. Renal perfusion is therefore a key determinant of glomerular filtration. Therefore the quantification of regional renal perfusion could provide important insights into renal function and renal (patho)physiology. Arterial spin labeling (ASL) based perfusion MRI techniques, can offer a noninvasive and reproducible way of measuring renal perfusion in animal models. This chapter addresses the basic concept of ASL-MRI.This chapter is based upon work from the COST Action PARENCHIMA, a community-driven network funded by the European Cooperation in Science and Technology (COST) program of the European Union, which aims to improve the reproducibility and standardization of renal MRI biomarkers. This introduction chapter is complemented by two separate chapters describing the experimental procedure and data analysis.
Collapse
Affiliation(s)
- Min-Chi Ku
- Berlin Ultrahigh Field Facility (B.U.F.F.), Max Delbrück Center for Molecular Medicine in the Helmholtz Association, Berlin, Germany
| | | | - Frank Kober
- Aix-Marseille Université, CNRS, Centre de Résonance Magnétique Biologique et Médicale (CRMBM), Marseille, France
| | - Thoralf Niendorf
- Berlin Ultrahigh Field Facility (B.U.F.F.), Max Delbrück Center for Molecular Medicine (MDC) in the Helmholtz Association, Berlin, Germany
| |
Collapse
|
13
|
Zöllner FG, Dastrù W, Irrera P, Longo DL, Bennett KM, Beeman SC, Bretthorst GL, Garbow JR. Analysis Protocol for Dynamic Contrast Enhanced (DCE) MRI of Renal Perfusion and Filtration. Methods Mol Biol 2021; 2216:637-653. [PMID: 33476028 PMCID: PMC9703217 DOI: 10.1007/978-1-0716-0978-1_38] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 06/12/2023]
Abstract
Here we present an analysis protocol for dynamic contrast enhanced magnetic resonance imaging (DCE-MRI) data of the kidneys. It covers comprehensive steps to facilitate signal to contrast agent concentration mapping via T1 mapping and the calculation of renal perfusion and filtration parametric maps using model-free approaches, model free analysis using deconvolution, the Toft's model and a Bayesian approach.This chapter is based upon work from the COST Action PARENCHIMA, a community-driven network funded by the European Cooperation in Science and Technology (COST) program of the European Union, which aims to improve the reproducibility and standardization of renal MRI biomarkers. This analysis protocol chapter is complemented by two separate chapters describing the basic concept and experimental procedure.
Collapse
Affiliation(s)
- Frank G Zöllner
- Computer Assisted Clinical Medicine, Medical Faculty Mannheim, Heidelberg University, Mannheim, Germany
| | - Walter Dastrù
- Department of Molecular Biotechnology and Health Sciences, University of Torino, Torino, Italy
| | - Pietro Irrera
- University of Campania "Luigi Vanvitelli", Naples, Italy
| | - Dario Livio Longo
- Institute of Biostructures and Bioimaging (IBB), Italian National Research Council (CNR), Torino, Italy.
| | - Kevin M Bennett
- Washington University School of Medicine, St. Louis, MO, USA
| | - Scott C Beeman
- Washington University School of Medicine, St. Louis, MO, USA
| | | | - Joel R Garbow
- Washington University School of Medicine, St. Louis, MO, USA
| |
Collapse
|
14
|
Sodium ( 23Na) MRI of the Kidney: Basic Concept. Methods Mol Biol 2021; 2216:257-266. [PMID: 33476005 DOI: 10.1007/978-1-0716-0978-1_15] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/14/2022]
Abstract
The handling of sodium by the renal system is a key indicator of renal function. Alterations in the corticomedullary distribution of sodium are considered important indicators of pathology in renal diseases. The derangement of sodium handling can be noninvasively imaged using sodium magnetic resonance imaging (23Na MRI), with data analysis allowing for the assessment of the corticomedullary sodium gradient. Here we introduce sodium imaging, describe the existing methods, and give an overview of preclinical sodium imaging applications to illustrate the utility and applicability of this technique for measuring renal sodium handling.This chapter is based upon work from the COST Action PARENCHIMA, a community-driven network funded by the European Cooperation in Science and Technology (COST) program of the European Union, which aims to improve the reproducibility and standardization of renal MRI biomarkers. This introduction chapter is complemented by two separate chapters describing the experimental procedure and data analysis.
Collapse
|
15
|
Pedersen M, Irrera P, Dastrù W, Zöllner FG, Bennett KM, Beeman SC, Bretthorst GL, Garbow JR, Longo DL. Dynamic Contrast Enhancement (DCE) MRI-Derived Renal Perfusion and Filtration: Basic Concepts. Methods Mol Biol 2021; 2216:205-227. [PMID: 33476002 DOI: 10.1007/978-1-0716-0978-1_12] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/14/2022]
Abstract
Dynamic contrast-enhanced (DCE) MRI monitors the transit of contrast agents, typically gadolinium chelates, through the intrarenal regions, the renal cortex, the medulla, and the collecting system. In this way, DCE-MRI reveals the renal uptake and excretion of the contrast agent. An optimal DCE-MRI acquisition protocol involves finding a good compromise between whole-kidney coverage (i.e., 3D imaging), spatial and temporal resolution, and contrast resolution. By analyzing the enhancement of the renal tissues as a function of time, one can determine indirect measures of clinically important single-kidney parameters as the renal blood flow, glomerular filtration rate, and intrarenal blood volumes. Gadolinium-containing contrast agents may be nephrotoxic in patients suffering from severe renal dysfunction, but otherwise DCE-MRI is clearly useful for diagnosis of renal functions and for assessing treatment response and posttransplant rejection.Here we introduce the concept of renal DCE-MRI, describe the existing methods, and provide an overview of preclinical DCE-MRI applications to illustrate the utility of this technique to measure renal perfusion and glomerular filtration rate in animal models.This publication is based upon work from the COST Action PARENCHIMA, a community-driven network funded by the European Cooperation in Science and Technology (COST) program of the European Union, which aims to improve the reproducibility and standardization of renal MRI biomarkers. This introduction is complemented by two separate publications describing the experimental procedure and data analysis.
Collapse
Affiliation(s)
- Michael Pedersen
- Department of Clinical Medicine - Comparative Medicine Lab, Aarhus University, Aarhus, Denmark
| | - Pietro Irrera
- University of Campania "Luigi Vanvitelli", Napoli, Italy
| | - Walter Dastrù
- Department of Molecular Biotechnology and Health Sciences, University of Torino, Torino, Italy
| | - Frank G Zöllner
- Computer Assisted Clinical Medicine, Medical Faculty Mannheim, Heidelberg University, Mannheim, Germany
| | - Kevin M Bennett
- Washington University School of Medicine, St. Louis, MO, USA
| | - Scott C Beeman
- Washington University School of Medicine, St. Louis, MO, USA
| | | | - Joel R Garbow
- Washington University School of Medicine, St. Louis, MO, USA
| | - Dario Livio Longo
- Institute of Biostructures and Bioimaging (IBB), Italian National Research Council (CNR), Torino, Italy.
| |
Collapse
|
16
|
Irrera P, Consolino L, Cutrin JC, Zöllner FG, Longo DL. Dual assessment of kidney perfusion and pH by exploiting a dynamic CEST-MRI approach in an acute kidney ischemia-reperfusion injury murine model. NMR IN BIOMEDICINE 2020; 33:e4287. [PMID: 32153058 DOI: 10.1002/nbm.4287] [Citation(s) in RCA: 14] [Impact Index Per Article: 3.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 05/14/2019] [Revised: 02/03/2020] [Accepted: 02/18/2020] [Indexed: 06/10/2023]
Abstract
Several factors can lead to acute kidney injury, but damage following ischemia and reperfusion injuries is the main risk factor and usually develops into chronic disease. MRI has often been proposed as a method with which to assess renal function. It does so by measuring the renal perfusion of an injected Gd-based contrast agent. The use of pH-responsive agents as part of the CEST (chemical exchange saturation transfer)-MRI technique has recently shown that pH homeostasis is also an important indicator of kidney functionality. However, there is still a need for methods that can provide more than one type of information following the injection of a single contrast agent for the characterization of renal function. Herein we propose, for the first time, dynamic CEST acquisition following iopamidol injection to quantify renal function by assessing both perfusion and pH homeostasis. The aim of this study is to assess renal functionality in a murine unilateral ischemia-reperfusion injury model at two time points (3 and 7 days) after acute kidney injury. The renal-perfusion estimates measured with iopamidol were compared with those obtained with a gadolinium-based agent, via a dynamic contrast enhanced (DCE)-MRI approach, to validate the proposed method. Compared with the contralateral kidneys, the clamped ones showed a significant decrease in renal perfusion, as measured using the DCE-MRI approach, which is consistent with reduced filtration capability. Dynamic CEST-MRI findings provided similar results, indicating that the clamped kidneys displayed significantly reduced renal filtration that persisted up to 7 days after the damage. In addition, CEST-MRI pH imaging showed that the clamped kidneys displayed significantly increased pH values, reflecting the disturbance to pH homeostasis. Our results demonstrate that a single CEST-MRI contrast agent can provide multiple types of information related to renal function and can discern healthy kidneys from pathological ones by combining perfusion measurements with renal pH mapping.
Collapse
Affiliation(s)
- Pietro Irrera
- Università degli Studi della Campania "Luigi Vanvitelli", Napoli, Italy
- Istituto di Biostrutture e Bioimmagini (IBB), Consiglio Nazionale delle Ricerche (CNR), Torino, Italy
| | - Lorena Consolino
- Centro di Imaging Molecolare, Dipartimento di Biotecnologie Molecolari e Scienze per la Salute, Università degli Studi di Torino, Torino, Italy
| | - Juan Carlos Cutrin
- Centro di Imaging Molecolare, Dipartimento di Biotecnologie Molecolari e Scienze per la Salute, Università degli Studi di Torino, Torino, Italy
| | - Frank G Zöllner
- Computer Assisted Clinical Medicine, Medical Faculty Mannheim, Heidelberg University, Mannheim, Germany
| | - Dario Livio Longo
- Istituto di Biostrutture e Bioimmagini (IBB), Consiglio Nazionale delle Ricerche (CNR), Torino, Italy
| |
Collapse
|
17
|
Niendorf T, Seeliger E, Cantow K, Flemming B, Waiczies S, Pohlmann A. Probing renal blood volume with magnetic resonance imaging. Acta Physiol (Oxf) 2020; 228:e13435. [PMID: 31876349 DOI: 10.1111/apha.13435] [Citation(s) in RCA: 13] [Impact Index Per Article: 3.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/20/2019] [Revised: 12/18/2019] [Accepted: 12/19/2019] [Indexed: 02/06/2023]
Abstract
Damage to the kidney substantially reduces life expectancy. Renal tissue hypoperfusion and hypoxia are key elements in the pathophysiology of acute kidney injury and its progression to chronic kidney disease. In vivo assessment of renal haemodynamics and tissue oxygenation remains a challenge. Blood oxygenation level-dependent (BOLD) magnetic resonance imaging (MRI) is sensitive to changes in the effective transversal relaxation time (T2 *) in vivo, and is non-invasive and indicative of renal tissue oxygenation. However, the renal T2 * to tissue pO2 relationship is not governed exclusively by renal blood oxygenation, but is affected by physiological confounders with alterations in renal blood volume fraction (BVf) being of particular relevance. To decipher this interference probing renal BVf is essential for the pursuit of renal MR oximetry. Superparamagnetic iron oxide nanoparticle (USPIO) preparations can be used as MRI visible blood pool markers for detailing alterations in BVf. This review promotes the opportunities of MRI-based assessment of renal BVf. Following an outline on the specifics of renal oxygenation and perfusion, changes in renal BVf upon interventions and their potential impact on renal T2 * are discussed. We also describe the basic principles of renal BVf assessment using ferumoxytol-enhanced MRI in the equilibrium concentration regimen. We demonstrate that ferumoxytol does not alter control of renal haemodynamics and oxygenation. Preclinical applications of ferumoxytol enhanced renal MRI as well as considerations for its clinical implementation for examining renal BVf changes are provided alongside practical considerations. Finally, we explore the future directions of MRI-based assessment of renal BVf.
Collapse
Affiliation(s)
- Thoralf Niendorf
- Berlin Ultrahigh Field Facility (B.U.F.F.) Max Delbrück Center for Molecular Medicine in the Helmholtz Association Berlin Germany
| | - Erdmann Seeliger
- Institute of Physiology Charité – Universitätsmedizin Berlin Campus Mitte, and Center for Cardiovascular Research (CCR) Berlin Germany
| | - Kathleen Cantow
- Institute of Physiology Charité – Universitätsmedizin Berlin Campus Mitte, and Center for Cardiovascular Research (CCR) Berlin Germany
| | - Bert Flemming
- Institute of Physiology Charité – Universitätsmedizin Berlin Campus Mitte, and Center for Cardiovascular Research (CCR) Berlin Germany
| | - Sonia Waiczies
- Berlin Ultrahigh Field Facility (B.U.F.F.) Max Delbrück Center for Molecular Medicine in the Helmholtz Association Berlin Germany
| | - Andreas Pohlmann
- Berlin Ultrahigh Field Facility (B.U.F.F.) Max Delbrück Center for Molecular Medicine in the Helmholtz Association Berlin Germany
| |
Collapse
|
18
|
Bueters R, Bael A, Gasthuys E, Chen C, Schreuder MF, Frazier KS. Ontogeny and Cross-species Comparison of Pathways Involved in Drug Absorption, Distribution, Metabolism, and Excretion in Neonates (Review): Kidney. Drug Metab Dispos 2020; 48:353-367. [DOI: 10.1124/dmd.119.089755] [Citation(s) in RCA: 15] [Impact Index Per Article: 3.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/18/2019] [Accepted: 02/04/2020] [Indexed: 02/06/2023] Open
|
19
|
Pedersen M, Ursprung S, Jensen JD, Jespersen B, Gallagher F, Laustsen C. Hyperpolarised 13C-MRI metabolic and functional imaging: an emerging renal MR diagnostic modality. MAGMA (NEW YORK, N.Y.) 2020; 33:23-32. [PMID: 31782036 DOI: 10.1007/s10334-019-00801-y] [Citation(s) in RCA: 8] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 07/01/2019] [Revised: 10/21/2019] [Accepted: 11/12/2019] [Indexed: 12/11/2022]
Abstract
Magnetic resonance imaging (MRI) is a well-established modality for assessing renal morphology and function, as well as changes that occur during disease. However, the significant metabolic changes associated with renal disease are more challenging to assess with MRI. Hyperpolarized carbon-13 MRI is an emerging technique which provides an opportunity to probe metabolic alterations at high sensitivity by providing an increase in the signal-to-noise ratio of 20,000-fold or more. This review will highlight the current status of hyperpolarised 13C-MRI and its translation into the clinic and how it compares to metabolic measurements provided by competing technologies such as positron emission tomography (PET).
Collapse
Affiliation(s)
| | - Stephan Ursprung
- Department of Radiology, University of Cambridge, Addenbrooke's Hospital, Cambridge, UK
| | - Jens Dam Jensen
- Department of Renal Medicine, Aarhus University Hospital, Aarhus, Denmark
| | - Bente Jespersen
- Department of Renal Medicine, Aarhus University Hospital, Aarhus, Denmark
| | - Ferdia Gallagher
- Department of Radiology, University of Cambridge, Addenbrooke's Hospital, Cambridge, UK
| | - Christoffer Laustsen
- MR Research Centre, Department of Clinical Medicine, Aarhus University Hospital, Palle Juul Jensens Boulevard, 8200, Aarhus N, Denmark.
| |
Collapse
|
20
|
Zöllner FG, Šerifović-Trbalić A, Kabelitz G, Kociński M, Materka A, Rogelj P. Image registration in dynamic renal MRI-current status and prospects. MAGNETIC RESONANCE MATERIALS IN PHYSICS BIOLOGY AND MEDICINE 2019; 33:33-48. [PMID: 31598799 PMCID: PMC7210245 DOI: 10.1007/s10334-019-00782-y] [Citation(s) in RCA: 12] [Impact Index Per Article: 2.4] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Subscribe] [Scholar Register] [Received: 06/30/2019] [Revised: 09/16/2019] [Accepted: 09/25/2019] [Indexed: 12/26/2022]
Abstract
Magnetic resonance imaging (MRI) modalities have achieved an increasingly important role in the clinical work-up of chronic kidney diseases (CKD). This comprises among others assessment of hemodynamic parameters by arterial spin labeling (ASL) or dynamic contrast-enhanced (DCE-) MRI. Especially in the latter, images or volumes of the kidney are acquired over time for up to several minutes. Therefore, they are hampered by motion, e.g., by pulsation, peristaltic, or breathing motion. This motion can hinder subsequent image analysis to estimate hemodynamic parameters like renal blood flow or glomerular filtration rate (GFR). To overcome motion artifacts in time-resolved renal MRI, a wide range of strategies have been proposed. Renal image registration approaches could be grouped into (1) image acquisition techniques, (2) post-processing methods, or (3) a combination of image acquisition and post-processing approaches. Despite decades of progress, the translation in clinical practice is still missing. The aim of the present article is to discuss the existing literature on renal image registration techniques and show today’s limitations of the proposed techniques that hinder clinical translation. This paper includes transformation, criterion function, and search types as traditional components and emerging registration technologies based on deep learning. The current trend points towards faster registrations and more accurate results. However, a standardized evaluation of image registration in renal MRI is still missing.
Collapse
Affiliation(s)
- Frank G Zöllner
- Computer Assisted Clinical Medicine, Medical Faculty Mannheim, Heidelberg University, Theodor-Kutzer-Ufer 1-3, 68167, Mannheim, Germany.
| | | | - Gordian Kabelitz
- Computer Assisted Clinical Medicine, Medical Faculty Mannheim, Heidelberg University, Theodor-Kutzer-Ufer 1-3, 68167, Mannheim, Germany
| | - Marek Kociński
- Institute of Electronics, Lodz University of Technology, Lodz, Poland
| | - Andrzej Materka
- Institute of Electronics, Lodz University of Technology, Lodz, Poland
| | - Peter Rogelj
- Faculty of Mathematics, Natural Sciences and Information Technologies, University of Primorska, Koper, Slovenia
| |
Collapse
|
21
|
Hernandez-Garcia L, Lahiri A, Schollenberger J. Recent progress in ASL. Neuroimage 2019; 187:3-16. [PMID: 29305164 PMCID: PMC6030511 DOI: 10.1016/j.neuroimage.2017.12.095] [Citation(s) in RCA: 62] [Impact Index Per Article: 12.4] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/30/2017] [Revised: 12/21/2017] [Accepted: 12/30/2017] [Indexed: 11/26/2022] Open
Abstract
This article aims to provide the reader with an overview of recent developments in Arterial Spin Labeling (ASL) MRI techniques. A great deal of progress has been made in recent years in terms of the SNR and acquisition speed. New strategies have been introduced to improve labeling efficiency, reduce artefacts, and estimate other relevant physiological parameters besides perfusion. As a result, ASL techniques has become a reliable workhorse for researchers as well as clinicians. After a brief overview of the technique's fundamentals, this article will review new trends and variants in ASL including vascular territory mapping and velocity selective ASL, as well as arterial blood volume imaging techniques. This article will also review recent processing techniques to reduce partial volume effects and physiological noise. Next the article will examine how ASL techniques can be leveraged to calculate additional physiological parameters beyond perfusion and finally, it will review a few recent applications of ASL in the literature.
Collapse
Affiliation(s)
| | - Anish Lahiri
- FMRI Laboratory, University of Michigan, United States
| | | |
Collapse
|
22
|
Taso M, Guidon A, Alsop DC. Influence of background suppression and retrospective realignment on free-breathing renal perfusion measurement using pseudo-continuous ASL. Magn Reson Med 2018; 81:2439-2449. [PMID: 30474312 DOI: 10.1002/mrm.27575] [Citation(s) in RCA: 12] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/03/2018] [Revised: 09/24/2018] [Accepted: 09/27/2018] [Indexed: 12/27/2022]
Abstract
PURPOSE To assess the influence of background suppression and retrospective realignment on physiological noise and image quality in free-breathing renal pseudo-continuous arterial spin labeling (pCASL). METHODS Ten subjects were scanned at 3T with a pCASL prepared single-slice coronal acquisition through the kidneys under free breathing. Multiple acquisitions were performed with various levels of residual background signal based on optimization of pulse timings to achieve specific background suppression levels (<2%, <5%, <10%, <20%). A retrospective non-rigid motion-correction strategy was also implemented. RESULTS Decreasing level of residual background signal was associated with higher temporal SNR. The retrospective motion-correction provided an additional but not statistically significant improvement in tSNR. The highest image quality was obtained with the lowest level of residual background signal accompanied by the retrospective motion-correction, although no significant difference in quantitative renal blood-flow could be observed. CONCLUSIONS Renal perfusion measurement with ASL under free breathing is feasible and robust against physiological noise when using strong background suppression strategies. Finally, retrospective motion-correction further improves image quality but cannot replace background suppression.
Collapse
Affiliation(s)
- Manuel Taso
- Division of MRI Research, Department of Radiology, Beth Israel Deaconess Medical Center and Harvard Medical School, Boston, Massachusetts
| | - Arnaud Guidon
- Global MR applications and workflow, GE Healthcare, Boston, Massachusetts
| | - David C Alsop
- Division of MRI Research, Department of Radiology, Beth Israel Deaconess Medical Center and Harvard Medical School, Boston, Massachusetts
| |
Collapse
|
23
|
Hu G, Yang Z, Liang W, Lai C, Mei Y, Li Y, Xu J, Luo L, Quan X. Intravoxel Incoherent Motion and Arterial Spin Labeling MRI Analysis of Reversible Unilateral Ureteral Obstruction in Rats. J Magn Reson Imaging 2018; 50:288-296. [PMID: 30328247 DOI: 10.1002/jmri.26536] [Citation(s) in RCA: 8] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/23/2018] [Revised: 09/20/2018] [Accepted: 09/20/2018] [Indexed: 12/30/2022] Open
Abstract
BACKGROUND Renal fibrosis is a common consequence of chronic kidney disease (CKD) and is the mechanism by which various forms of CKD progress to endstage renal failure. Accurate assessment of renal fibrosis is important for treatment. PURPOSE To measure longitudinal changes of intravoxel incoherent motion (IVIM) and arterial spin labeling (ASL) before and after reversible unilateral ureteral obstruction in an animal model. STUDY TYPE Self-controlled animal study. ANIMAL MODEL Surgical obstruction of the ureters was performed and then removed after 5 days. Rats were scanned on Days 0, 1, 3, and 5 after creating the obstruction and on Days 4, 7, and 12 after releasing the obstruction. FIELD STRENGTH/SEQUENCE 3.0T/IVIM/ASL. ASSESSMENT The apparent diffusion coefficient (ADC), pure molecular diffusion (D), perfusion fraction (f), pseudodiffusion (D*), and renal blood flow (RBF) obtained from the ASL were measured. STATISTICAL TESTS Using SPSS v. 20.0 software, P < 0.05 were considered statistically significant. The data from each timepoint were compared using one-way analysis of variance and correlation analysis was applied to various parameters. RESULTS The postobstruction kidneys showed renal tubule swelling and increased collagen fiber content. Renal tubule swelling was relieved after reversing the obstruction, but Masson staining and cell density analysis revealed progressive changes that were primarily localized to the medulla. In general, ADC, D, f, D*, and RBF decreased with time during the 5 days of obstruction, and increased after release of the obstruction. ADC positively correlated with D, f, D*, and RBF (r = 0.415, r = 0.634, r = 0.465 r = 0.586, P < 0.001, respectively) in the cortex in this study. Also, ADC showed a positive correlation with D, f, and D* (r = 0.724, r = 0.749, r = 0.151, P < 0.001, respectively) in the medulla. DATA CONCLUSION Kidney perfusion was the major factor affecting ADC. Functional imaging may be useful for following progression of CKD. LEVEL OF EVIDENCE 1 Technical Efficacy: Stage 2 J. Magn. Reson. Imaging 2019;50:288-296.
Collapse
Affiliation(s)
- Genwen Hu
- Department of Radiology, Shenzhen People's Hospital (Second Clinical Medical College of Jinan University), Shenzhen, P.R. China
| | - Zhong Yang
- Department of Radiology, Shenzhen People's Hospital (Second Clinical Medical College of Jinan University), Shenzhen, P.R. China
| | - Wen Liang
- Department of Radiology, Zhujiang Hospital, Southern Medical University, Guangzhou, P.R. China
| | - Caiyong Lai
- Department of Urology, First Affiliated Hospital of Jinan University, Guangzhou, P.R. China
| | - Yingjie Mei
- MR Clinical Science, Philips Healthcare, GuangZhou, P.R. China
| | - Yufa Li
- Department of Pathology, Guangdong General Hospital, Guangdong Academy of Medical Sciences, Guangzhou, P.R. China
| | - Jianmin Xu
- Department of Radiology, Shenzhen People's Hospital (Second Clinical Medical College of Jinan University), Shenzhen, P.R. China
| | - Liangping Luo
- Medical Imaging Center, First Affiliated Hospital of Jinan University, Guangzhou, P.R. China
| | - Xianyue Quan
- Department of Radiology, Zhujiang Hospital, Southern Medical University, Guangzhou, P.R. China
| |
Collapse
|
24
|
Liu J, Han Z, Chen G, Li Y, Zhang J, Xu J, van Zijl PCM, Zhang S, Liu G. CEST MRI of sepsis-induced acute kidney injury. NMR IN BIOMEDICINE 2018; 31:e3942. [PMID: 29897643 DOI: 10.1002/nbm.3942] [Citation(s) in RCA: 25] [Impact Index Per Article: 4.2] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 02/20/2018] [Revised: 04/15/2018] [Accepted: 04/23/2018] [Indexed: 06/08/2023]
Abstract
Sepsis-induced acute kidney injury (SAKI) is a major complication of kidney disease associated with increased mortality and faster progression. Therefore, the development of imaging biomarkers to detect septic AKI is of great clinical interest. In this study, we aimed to characterize the endogenous chemical exchange saturation transfer (CEST) MRI contrast in the lipopolysaccharide (LPS)-induced SAKI mouse model and to investigate the use of CEST MRI for detecting such injury. We used a SAKI mouse model that was generated by i.p. injection of 10 mg/kg LPS. The resulting kidney injury was confirmed by the elevation of serum creatinine and histology. MRI assessments were performed 24 h after LPS injection, including CEST MRI at different B1 strengths (1, 1.8 and 3 μT), T1 mapping, T2 mapping and conventional magnetization transfer contrast (MTC) MRI. The CEST MRI results were analyzed using Z-spectra, in which the normalized water signal saturation (Ssat /S0 ) is measured as a function of saturation frequency. Substantial decreases in CEST contrast were observed at both 3.5 and - 3.5 ppm frequency offset from water at all B1 powers, with the most significant difference obtained at a B1 of 1.8 μT. The average Ssat /S0 differences between injured and normal kidneys were 0.07 (0.55 ± 0.04 versus 0.62 ± 0.04, P = 0.0028) and 0.07 (0.50 ± 0.04 versus 0.57 ± 0.03, P = 0.0008) for 3.5 and - 3.5 ppm, respectively. In contrast, the T1 and T2 relaxation times and MTC contrast in the injured kidneys did not show a significant change compared with the normal control. Our results showed that CEST MRI is more sensitive to the pathological changes in injured kidneys than the changes in T1 , T2 and MTC effect, indicating its potential clinical utility for molecular imaging of renal diseases.
Collapse
Affiliation(s)
- Jing Liu
- Graduate College, Southern Medical University, Guangzhou, Guangdong, China
- Department of Radiology, Guangdong Provincial People's Hospital/Guangdong General Hospital, Guangzhou, Guangdong, China
- Department of Radiology, Johns Hopkins University School of Medicine, Baltimore, MD, USA
| | - Zheng Han
- Department of Radiology, Johns Hopkins University School of Medicine, Baltimore, MD, USA
| | - Guoli Chen
- Department of Pathology and Laboratory Medicine, Pennsylvania State University College of Medicine, Hershey, PA, USA
| | - Yuguo Li
- Department of Radiology, Johns Hopkins University School of Medicine, Baltimore, MD, USA
| | - Jia Zhang
- Department of Radiology, Johns Hopkins University School of Medicine, Baltimore, MD, USA
| | - Jiadi Xu
- Department of Radiology, Johns Hopkins University School of Medicine, Baltimore, MD, USA
- F.M. Kirby Research Center for Functional Brain Imaging, Kennedy Krieger Institute, Baltimore, MD, USA
| | - Peter C M van Zijl
- Department of Radiology, Johns Hopkins University School of Medicine, Baltimore, MD, USA
- F.M. Kirby Research Center for Functional Brain Imaging, Kennedy Krieger Institute, Baltimore, MD, USA
| | - Shuixing Zhang
- Graduate College, Southern Medical University, Guangzhou, Guangdong, China
- Department of Radiology, Guangdong Provincial People's Hospital/Guangdong General Hospital, Guangzhou, Guangdong, China
- Department of Radiology, The First Affiliated Hospital of Jinan University, Guangzhou, China
| | - Guanshu Liu
- Department of Radiology, Johns Hopkins University School of Medicine, Baltimore, MD, USA
- F.M. Kirby Research Center for Functional Brain Imaging, Kennedy Krieger Institute, Baltimore, MD, USA
| |
Collapse
|
25
|
Apparent Diffusion Coefficient is a Useful Biomarker for Monitoring Adipose-Derived Mesenchymal Stem Cell Therapy of Renal Ischemic-Reperfusion Injury. Mol Imaging Biol 2018; 20:750-760. [DOI: 10.1007/s11307-018-1184-0] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/04/2023]
|
26
|
Zhang B, Dong Y, Guo B, Chen W, Ouyang F, Lian Z, Liu J, Zhang S. Application of noninvasive functional imaging to monitor the progressive changes in kidney diffusion and perfusion in contrast-induced acute kidney injury rats at 3.0 T. Abdom Radiol (NY) 2018; 43:655-662. [PMID: 28677006 DOI: 10.1007/s00261-017-1247-8] [Citation(s) in RCA: 14] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/11/2022]
Abstract
OBJECTIVES Contrast-induced acute kidney injury is a prevalent cause of renal failure, and the noninvasive tools to monitor its progress are lacking. We applied intravoxel incoherent motion (IVIM) DWI to measure the progressive changes in kidney diffusion and perfusion of CI-AKI. METHODS Twenty-four rats received Iopromide (370 mg/ml, 1600 mg iodine/kg) to induce CI-AKI. IVIM DWI was performed on rats (n = 6) at 24 h prior to and 12, 24, 48, 72, and 96 h after the injection using a 3.0 T MRI scanner. The progressive changes in the diffusion (D) and perfusion parameters (D* and f) were studied in the cortex (CO), outer medulla (OM), and inner medulla (IM). For the histology group (n = 18), three rats were sacrificed at each time point. RESULTS In the CO, D reduced progressively from 24 to 48 h (P < 0.001) and increased starting from 72 h (P < 0.001). However, D decreased until to 72 h in the medulla (P < 0.001) and increased starting from 96 h (P < 0.001). D* decreased to the bottom at 24 h in the cortex and medulla (P = 0.037) and started to recover at 48 h (P = 0.007). f decreased in the cortex and medulla in an early stage (12 h) (P = 0.035) of CI-AKI and then ascended in the later stage (72 h) (P = 0.017). The H & E staining showed different degrees of serial pathological change including cloudy swelling, atrophy, even necrosis, and interstitial vasodilation of tubule epithelial cells and glomerulus cells. CONCLUSION Our study demonstrates the feasibility of using IVIM DWI to monitor the progress of CI-AKI, implying that IVIM DWI is a useful biomarker in the staging of CI-AKI.
Collapse
|
27
|
Non-Invasive Renal Perfusion Imaging Using Arterial Spin Labeling MRI: Challenges and Opportunities. Diagnostics (Basel) 2018; 8:diagnostics8010002. [PMID: 29303965 PMCID: PMC5871985 DOI: 10.3390/diagnostics8010002] [Citation(s) in RCA: 40] [Impact Index Per Article: 6.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/27/2017] [Revised: 12/25/2017] [Accepted: 01/02/2018] [Indexed: 12/28/2022] Open
Abstract
Tissue perfusion allows for delivery of oxygen and nutrients to tissues, and in the kidneys is also a key determinant of glomerular filtration. Quantification of regional renal perfusion provides a potential window into renal (patho) physiology. However, non-invasive, practical, and robust methods to measure renal perfusion remain elusive, particularly in the clinic. Arterial spin labeling (ASL), a magnetic resonance imaging (MRI) technique, is arguably the only available method with potential to meet all these needs. Recent developments suggest its viability for clinical application. This review addresses several of these developments and discusses remaining challenges with the emphasis on renal imaging in human subjects.
Collapse
|
28
|
Mariager CØ, Nielsen PM, Qi H, Ringgaard S, Laustsen C. Hyperpolarized 13
C,15
N2
-urea T2
relaxation changes in acute kidney injury. Magn Reson Med 2017; 80:696-702. [DOI: 10.1002/mrm.27050] [Citation(s) in RCA: 17] [Impact Index Per Article: 2.4] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/27/2017] [Revised: 11/29/2017] [Accepted: 11/29/2017] [Indexed: 01/18/2023]
Affiliation(s)
| | - Per Mose Nielsen
- MR Research Centre, Department of Clinical Medicine; Aarhus University; Aarhus Denmark
| | - Haiyun Qi
- MR Research Centre, Department of Clinical Medicine; Aarhus University; Aarhus Denmark
| | - Steffen Ringgaard
- MR Research Centre, Department of Clinical Medicine; Aarhus University; Aarhus Denmark
| | - Christoffer Laustsen
- MR Research Centre, Department of Clinical Medicine; Aarhus University; Aarhus Denmark
| |
Collapse
|
29
|
Romero CA, Cabral G, Knight RA, Ding G, Peterson EL, Carretero OA. Noninvasive measurement of renal blood flow by magnetic resonance imaging in rats. Am J Physiol Renal Physiol 2017; 314:F99-F106. [PMID: 28978533 DOI: 10.1152/ajprenal.00332.2017] [Citation(s) in RCA: 6] [Impact Index Per Article: 0.9] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/27/2022] Open
Abstract
Renal blood flow (RBF) provides important information regarding renal physiology and nephropathies. Arterial spin labeling-magnetic resonance imaging (ASL-MRI) is a noninvasive method of measuring blood flow without exogenous contrast media. However, low signal-to-noise ratio and respiratory motion artifacts are challenges for RBF measurements in small animals. Our objective was to evaluate the feasibility and reproducibility of RBF measurements by ASL-MRI using respiratory-gating and navigator correction methods to reduce motion artifacts. ASL-MRI images were obtained from the kidneys of Sprague-Dawley (SD) rats on a 7-Tesla Varian MRI system with a spin-echo imaging sequence. After 4 days, the study was repeated to evaluate its reproducibility. RBF was also measured in animals under unilateral nephrectomy and in renal artery stenosis (RST) to evaluate the sensitivity in high and low RBF models, respectively. RBF was also evaluated in Dahl salt-sensitive (SS) rats and spontaneous hypertensive rats (SHR). In SD rats, the cortical RBFs (cRBF) were 305 ± 59 and 271.8 ± 39 ml·min-1·100 g tissue-1 in the right and left kidneys, respectively. Retest analysis revealed no differences ( P = 0.2). The test-retest reliability coefficient was 92 ± 5%. The cRBFs before and after the nephrectomy were 296.8 ± 30 and 428.2 ± 45 ml·min-1·100 g tissue-1 ( P = 0.02), respectively. The kidneys with RST exhibited a cRBF decrease compared with sham animals (86 ± 17.6 vs. 198 ± 33.7 ml·min-1·100 g tissue-1; P < 0.01). The cRBFs in SD, Dahl-SS, and SHR rats were not different ( P = 0.35). We conclude that ASL-MRI performed with navigator correction and respiratory gating is a feasible and reliable noninvasive method for measuring RBF in rats.
Collapse
Affiliation(s)
- Cesar A Romero
- Hypertension and Vascular Research Division, Department of Internal Medicine, Henry Ford Hospital , Detroit, Michigan
| | - Glauber Cabral
- Department of Neurology-NMR Research, Henry Ford Hospital , Detroit, Michigan
| | - Robert A Knight
- Department of Neurology-NMR Research, Henry Ford Hospital , Detroit, Michigan
| | - Guangliang Ding
- Department of Neurology-NMR Research, Henry Ford Hospital , Detroit, Michigan
| | - Edward L Peterson
- Department of Public Health Sciences, Henry Ford Hospital , Detroit, Michigan
| | - Oscar A Carretero
- Hypertension and Vascular Research Division, Department of Internal Medicine, Henry Ford Hospital , Detroit, Michigan
| |
Collapse
|
30
|
Longo DL, Cutrin JC, Michelotti F, Irrera P, Aime S. Noninvasive evaluation of renal pH homeostasis after ischemia reperfusion injury by CEST-MRI. NMR IN BIOMEDICINE 2017; 30:e3720. [PMID: 28370530 DOI: 10.1002/nbm.3720] [Citation(s) in RCA: 33] [Impact Index Per Article: 4.7] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 11/14/2016] [Revised: 02/06/2017] [Accepted: 02/06/2017] [Indexed: 06/07/2023]
Abstract
Acute kidney injury (AKI) in mice caused by sustained ischemia followed by reperfusion is associated with acute tubular necrosis and renal dysfunctional blood flow. Although the principal role of the kidney is the maintenance of acid-base balance, current imaging approaches are unable to assess this important parameter, and clinical biomarkers are not robust enough in evaluating the severity of kidney damage. Therefore, novel noninvasive imaging approaches are needed to assess the acid-base homeostasis in vivo. This study investigates the usefulness of MRI-chemical exchange saturation transfer (CEST) pH imaging (through iopamidol injection) in characterizing moderate and severe AKI in mice following unilateral ischemia reperfusion injury. Moderate (20 min) and severe (40 min) ischemia were induced in Balb/C mice, which were imaged at several time points thereafter (Days 0, 1, 2, 7). A significant increase of renal pH values was observed as early as one day after the ischemia reperfusion damage for both moderate and severe ischemia. MRI-CEST pH imaging distinguished the evolution of moderate from severe AKI. A recovery of normal renal pH values was observed for moderate AKI, whereas a persisting renal pH increase was observed for severe AKI on Day 7. Renal filtration fraction was significantly lower for clamped kidneys (0.54-0.57) in comparison to contralateral kidneys (0.84-0.86) following impairment of glomerular filtration. The severe AKI group showed a reduced filtration fraction even after 7 days (0.38 for the clamped kidneys). Notably, renal pH values were significantly correlated with the histopathological score. In conclusion, MRI-CEST pH mapping is a valid tool for the noninvasive evaluation of both acid-base balance and renal filtration in patients with ischemia reperfusion injury.
Collapse
Affiliation(s)
- Dario Livio Longo
- Istituto di Biostrutture e Bioimmagini (CNR), c/o Centro di Biotecnologie Molecolari, Torino, Italy
- Dipartimento di Biotecnologie Molecolari e Scienze per la Salute, Università degli Studi di Torino, Torino, Italy
| | - Juan Carlos Cutrin
- Dipartimento di Biotecnologie Molecolari e Scienze per la Salute, Università degli Studi di Torino, Torino, Italy
| | - Filippo Michelotti
- Dipartimento di Biotecnologie Molecolari e Scienze per la Salute, Università degli Studi di Torino, Torino, Italy
| | - Pietro Irrera
- Dipartimento di Biotecnologie Molecolari e Scienze per la Salute, Università degli Studi di Torino, Torino, Italy
| | - Silvio Aime
- Dipartimento di Biotecnologie Molecolari e Scienze per la Salute, Università degli Studi di Torino, Torino, Italy
| |
Collapse
|
31
|
van Eijs MJM, van Zuilen AD, de Boer A, Froeling M, Nguyen TQ, Joles JA, Leiner T, Verhaar MC. Innovative Perspective: Gadolinium-Free Magnetic Resonance Imaging in Long-Term Follow-Up after Kidney Transplantation. Front Physiol 2017; 8:296. [PMID: 28559850 PMCID: PMC5432553 DOI: 10.3389/fphys.2017.00296] [Citation(s) in RCA: 8] [Impact Index Per Article: 1.1] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/09/2017] [Accepted: 04/24/2017] [Indexed: 12/23/2022] Open
Abstract
Since the mid-1980s magnetic resonance imaging (MRI) has been investigated as a non- or minimally invasive tool to probe kidney allograft function. Despite this long-standing interest, MRI still plays a subordinate role in daily practice of transplantation nephrology. With the introduction of new functional MRI techniques, administration of exogenous gadolinium-based contrast agents has often become unnecessary and true non-invasive assessment of allograft function has become possible. This raises the question why application of MRI in the follow-up of kidney transplantation remains restricted, despite promising results. Current literature on kidney allograft MRI is mainly focused on assessment of (sub) acute kidney injury after transplantation. The aim of this review is to survey whether MRI can provide valuable diagnostic information beyond 1 year after kidney transplantation from a mechanistic point of view. The driving force behind chronic allograft nephropathy is believed to be chronic hypoxia. Based on this, techniques that visualize kidney perfusion and oxygenation, scarring, and parenchymal inflammation deserve special interest. We propose that functional MRI mechanistically provides tools for diagnostic work-up in long-term follow-up of kidney allografts.
Collapse
Affiliation(s)
- Mick J M van Eijs
- Department of Nephrology and Hypertension, University Medical Center UtrechtUtrecht, Netherlands
| | - Arjan D van Zuilen
- Department of Nephrology and Hypertension, University Medical Center UtrechtUtrecht, Netherlands
| | - Anneloes de Boer
- Department of Radiology, University Medical Center UtrechtUtrecht, Netherlands
| | - Martijn Froeling
- Department of Radiology, University Medical Center UtrechtUtrecht, Netherlands
| | - Tri Q Nguyen
- Department of Pathology, University Medical Center UtrechtUtrecht, Netherlands
| | - Jaap A Joles
- Department of Nephrology and Hypertension, University Medical Center UtrechtUtrecht, Netherlands
| | - Tim Leiner
- Department of Radiology, University Medical Center UtrechtUtrecht, Netherlands
| | - Marianne C Verhaar
- Department of Nephrology and Hypertension, University Medical Center UtrechtUtrecht, Netherlands
| |
Collapse
|
32
|
Severe bilateral ischemic-reperfusion renal injury: hyperacute and acute changes in apparent diffusion coefficient, T1, and T2 mapping with immunohistochemical correlations. Sci Rep 2017; 7:1725. [PMID: 28496138 PMCID: PMC5431885 DOI: 10.1038/s41598-017-01895-x] [Citation(s) in RCA: 20] [Impact Index Per Article: 2.9] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/05/2016] [Accepted: 04/04/2017] [Indexed: 02/08/2023] Open
Abstract
The aim of this study was to investigate the hyperacute and acute changes in apparent diffusion coefficient (ADC), T1, and T2 mapping in rat kidneys after severe bilateral renal ischemic-reperfusion injury (IRI). After baseline MRI, 24 Spraque-Dawley rats with renal IRI were divided equally as group 1 (post-IRI MRI at 6 hours, days 1, 3, and 7) and groups 2, 3, and 4 (post-IRI MRI at 6 hours; 6 hours and day 1; 6 hours, days 1 and 3, respectively), while six other rats without IRI (group 5) were used as sham control. ADC, T1, and T2 values of the cortex and outer and inner stripes of outer medulla (OSOM and ISOM), and immunohistochemical studies assessing monocyte chemoattractant protein-1 (MCP-1), CD68+ cells, tubular cast formation, and collagen deposition in three zones at different time points were evaluated. Significantly reduced ADCs in OSOM and ISOM are noninvasive biomarkers denoting hyperacute damages after IRI. Linear regression analysis revealed a significant inverse correlation between 6-hour/baseline ADC ratios and MCP-1 staining (P < 0.001, r2 = 0.738). ADC, T1, and T2 values are useful for assessing variable IRI changes in different layers depending on underlying microstructural and histopathological changes at different time points.
Collapse
|
33
|
Nielsen PM, Laustsen C, Bertelsen LB, Qi H, Mikkelsen E, Kristensen MLV, Nørregaard R, Stødkilde-Jørgensen H. In situ lactate dehydrogenase activity: a novel renal cortical imaging biomarker of tubular injury? Am J Physiol Renal Physiol 2017; 312:F465-F473. [DOI: 10.1152/ajprenal.00561.2015] [Citation(s) in RCA: 29] [Impact Index Per Article: 4.1] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/17/2015] [Accepted: 09/15/2016] [Indexed: 12/11/2022] Open
Abstract
Renal ischemia-reperfusion injury is the state of which a tissue experiences injury after a phase of restrictive blood supply and recirculation. Ischemia-reperfusion injury (I/R-I) is a leading cause of acute kidney injury (AKI) in several disease states, including kidney transplantation, sepsis, and hypovolemic shock. The most common methods to evaluate AKI are creatinine clearance, plasma creatinine, blood urea nitrogen, or renal histology. However, currently, there are no precise methods to directly assess renal injury state noninvasively. Hyperpolarized 13C-pyruvate MRI enables noninvasive accurate quantification of the in vivo conversion of pyruvate to lactate, alanine, and bicarbonate. In the present study, we investigated the in situ alterations of metabolic conversion of pyruvate to lactate, alanine, and bicarbonate in a unilateral I/R-I rat model with 30 min and 60 min of ischemia followed by 24 h of reperfusion. The pyruvate conversion was unaltered compared with sham in the 30 min I/R-I group, while a significant reduced metabolic conversion was found in the postischemic kidney after 60 min of ischemia. This indicates that after 30 min of ischemia, the kidney maintains normal metabolic function in spite of decreased kidney function, whereas the postischemic kidney after 60 min of ischemia show a generally reduced metabolic enzyme activity concomitant with a reduced kidney function. We have confidence that these findings can have a high prognostic value in prediction of kidney injury and the outcome of renal injury.
Collapse
Affiliation(s)
- Per Mose Nielsen
- MRI Research Centre, Aarhus University Hospital, Aarhus N, Denmark; and
| | | | | | - Haiyun Qi
- MRI Research Centre, Aarhus University Hospital, Aarhus N, Denmark; and
| | - Emmeli Mikkelsen
- MRI Research Centre, Aarhus University Hospital, Aarhus N, Denmark; and
| | | | - Rikke Nørregaard
- Department of Clinical Medicine, Aarhus University Hospital, Aarhus N, Denmark
| | | |
Collapse
|
34
|
Zimmer F, Klotz S, Hoeger S, Yard BA, Krämer BK, Schad LR, Zöllner FG. Quantitative arterial spin labelling perfusion measurements in rat models of renal transplantation and acute kidney injury at 3T. Z Med Phys 2017; 27:39-48. [DOI: 10.1016/j.zemedi.2016.02.004] [Citation(s) in RCA: 12] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/27/2015] [Revised: 02/11/2016] [Accepted: 02/22/2016] [Indexed: 10/22/2022]
|
35
|
Fumarase activity: an in vivo and in vitro biomarker for acute kidney injury. Sci Rep 2017; 7:40812. [PMID: 28094329 PMCID: PMC5240145 DOI: 10.1038/srep40812] [Citation(s) in RCA: 32] [Impact Index Per Article: 4.6] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/16/2016] [Accepted: 12/12/2016] [Indexed: 11/08/2022] Open
Abstract
Renal ischemia/reperfusion injury (IRI) is a leading cause of acute kidney injury (AKI), and at present, there is a lack of reliable biomarkers that can diagnose AKI and measure early progression because the commonly used methods cannot evaluate single-kidney IRI. Hyperpolarized [1,4-13C2]fumarate conversion to [1,4-13C2]malate by fumarase has been proposed as a measure of necrosis in rat tumor models and in chemically induced AKI rats. Here we show that the degradation of cell membranes in connection with necrosis leads to elevated fumarase activity in plasma and urine and secondly that hyperpolarized [1,4-13C2]malate production 24 h after reperfusion correlates with renal necrosis in a 40-min unilateral ischemic rat model. Fumarase activity screening on bio-fluids can detect injury severity, in bilateral as well as unilateral AKI models, differentiating moderate and severe AKI as well as short- and long-term AKI. Furthermore after verification of renal injury by bio-fluid analysis the precise injury location can be monitored by in vivo measurements of the fumarase activity non-invasively by hyperpolarized [1,4-13C]fumarate MR imaging. The combined in vitro and in vivo biomarker of AKI responds to the essential requirements for a new reliable biomarker of AKI.
Collapse
|
36
|
Zöllner FG, Gaa T, Zimmer F, Ong MM, Riffel P, Hausmann D, Schoenberg SO, Weis M. [Quantitative perfusion imaging in magnetic resonance imaging]. Radiologe 2016; 56:113-23. [PMID: 26796337 DOI: 10.1007/s00117-015-0068-4] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/17/2022]
Abstract
CLINICAL/METHODICAL ISSUE Magnetic resonance imaging (MRI) is recognized for its superior tissue contrast while being non-invasive and free of ionizing radiation. Due to the development of new scanner hardware and fast imaging techniques during the last decades, access to tissue and organ functions became possible. One of these functional imaging techniques is perfusion imaging with which tissue perfusion and capillary permeability can be determined from dynamic imaging data. STANDARD RADIOLOGICAL METHODS Perfusion imaging by MRI can be performed by two approaches, arterial spin labeling (ASL) and dynamic contrast-enhanced (DCE) MRI. While the first method uses magnetically labelled water protons in arterial blood as an endogenous tracer, the latter involves the injection of a contrast agent, usually gadolinium (Gd), as a tracer for calculating hemodynamic parameters. PERFORMANCE Studies have demonstrated the potential of perfusion MRI for diagnostics and also for therapy monitoring. ACHIEVEMENTS The utilization and application of perfusion MRI are still restricted to specialized centers, such as university hospitals. A broad application of the technique has not yet been implemented. PRACTICAL RECOMMENDATIONS The MRI perfusion technique is a valuable tool that might come broadly available after implementation of standards on European and international levels. Such efforts are being promoted by the respective professional bodies.
Collapse
Affiliation(s)
- F G Zöllner
- Computerunterstützte Klinische Medizin, Medizinische Fakultät Mannheim, Universität Heidelberg, Theodor-Kutzer-Ufer 1-3, 68167, Mannheim, Deutschland.
| | - T Gaa
- Computerunterstützte Klinische Medizin, Medizinische Fakultät Mannheim, Universität Heidelberg, Theodor-Kutzer-Ufer 1-3, 68167, Mannheim, Deutschland
| | - F Zimmer
- Computerunterstützte Klinische Medizin, Medizinische Fakultät Mannheim, Universität Heidelberg, Theodor-Kutzer-Ufer 1-3, 68167, Mannheim, Deutschland
| | - M M Ong
- Institut für Klinische Radiologie und Nuklearmedizin, Universitätsmedizin Mannheim, Medizinische Fakultät Mannheim, Universität Heidelberg, Mannheim, Deutschland
| | - P Riffel
- Institut für Klinische Radiologie und Nuklearmedizin, Universitätsmedizin Mannheim, Medizinische Fakultät Mannheim, Universität Heidelberg, Mannheim, Deutschland
| | - D Hausmann
- Institut für Klinische Radiologie und Nuklearmedizin, Universitätsmedizin Mannheim, Medizinische Fakultät Mannheim, Universität Heidelberg, Mannheim, Deutschland
| | - S O Schoenberg
- Institut für Klinische Radiologie und Nuklearmedizin, Universitätsmedizin Mannheim, Medizinische Fakultät Mannheim, Universität Heidelberg, Mannheim, Deutschland
| | - M Weis
- Institut für Klinische Radiologie und Nuklearmedizin, Universitätsmedizin Mannheim, Medizinische Fakultät Mannheim, Universität Heidelberg, Mannheim, Deutschland
| |
Collapse
|
37
|
Chan JY, Ooi EH. Sensitivity of thermophysiological models of cryoablation to the thermal and biophysical properties of tissues. Cryobiology 2016; 73:304-315. [DOI: 10.1016/j.cryobiol.2016.10.006] [Citation(s) in RCA: 8] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/03/2016] [Revised: 10/18/2016] [Accepted: 10/20/2016] [Indexed: 10/20/2022]
|
38
|
Zhang JL, Conlin CC, Carlston K, Xie L, Kim D, Morrell G, Morton K, Lee VS. Optimization of saturation-recovery dynamic contrast-enhanced MRI acquisition protocol: monte carlo simulation approach demonstrated with gadolinium MR renography. NMR IN BIOMEDICINE 2016; 29:969-77. [PMID: 27200499 PMCID: PMC5206992 DOI: 10.1002/nbm.3553] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 08/18/2015] [Revised: 03/13/2016] [Accepted: 04/11/2016] [Indexed: 05/18/2023]
Abstract
Dynamic contrast-enhanced (DCE) MRI is widely used for the measurement of tissue perfusion and to assess organ function. MR renography, which is acquired using a DCE sequence, can measure renal perfusion, filtration and concentrating ability. Optimization of the DCE acquisition protocol is important for the minimization of the error propagation from the acquired signals to the estimated parameters, thus improving the precision of the parameters. Critical to the optimization of contrast-enhanced T1 -weighted protocols is the balance of the T1 -shortening effect across the range of gadolinium (Gd) contrast concentration in the tissue of interest. In this study, we demonstrate a Monte Carlo simulation approach for the optimization of DCE MRI, in which a saturation-recovery T1 -weighted gradient echo sequence is simulated and the impact of injected dose (D) and time delay (TD, for saturation recovery) is tested. The results show that high D and/or high TD cause saturation of the peak arterial signals and lead to an overestimation of renal plasma flow (RPF) and glomerular filtration rate (GFR). However, the use of low TD (e.g. 100 ms) and low D leads to similar errors in RPF and GFR, because of the Rician bias in the pre-contrast arterial signals. Our patient study including 22 human subjects compared TD values of 100 and 300 ms after the injection of 4 mL of Gd contrast for MR renography. At TD = 100 ms, we computed an RPF value of 157.2 ± 51.7 mL/min and a GFR of 33.3 ± 11.6 mL/min. These results were all significantly higher than the parameter estimates at TD = 300 ms: RPF = 143.4 ± 48.8 mL/min (p = 0.0006) and GFR = 30.2 ± 11.5 mL/min (p = 0.0015). In conclusion, appropriate optimization of the DCE MRI protocol using simulation can effectively improve the precision and, potentially, the accuracy of the measured parameters. Copyright © 2016 John Wiley & Sons, Ltd.
Collapse
Affiliation(s)
- Jeff L. Zhang
- Correspondence to: J. L. Zhang, University of Utah School of Medicine, Department of Radiology, 729 Arapeend Dr., Salt Lake City, UT 84108, USA.
| | | | | | | | | | | | | | | |
Collapse
|
39
|
Zhou HY, Chen TW, Zhang XM. Functional Magnetic Resonance Imaging in Acute Kidney Injury: Present Status. BIOMED RESEARCH INTERNATIONAL 2016; 2016:2027370. [PMID: 26925411 PMCID: PMC4746277 DOI: 10.1155/2016/2027370] [Citation(s) in RCA: 28] [Impact Index Per Article: 3.5] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 12/01/2015] [Revised: 01/05/2016] [Accepted: 01/06/2016] [Indexed: 12/27/2022]
Abstract
Acute kidney injury (AKI) is a common complication of hospitalization that is characterized by a sudden loss of renal excretory function and associated with the subsequent development of chronic kidney disease, poor prognosis, and increased mortality. Although the pathophysiology of renal functional impairment in the setting of AKI remains poorly understood, previous studies have identified changes in renal hemodynamics, perfusion, and oxygenation as key factors in the development and progression of AKI. The early assessment of these changes remains a challenge. Many established approaches are not applicable to humans because of their invasiveness. Functional renal magnetic resonance (MR) imaging offers an alternative assessment tool that could be used to evaluate renal morphology and function noninvasively and simultaneously. Thus, the purpose of this review is to illustrate the principle, application, and role of the techniques of functional renal MR imaging, including blood oxygen level-dependent imaging, arterial spin labeling, and diffusion-weighted MR imaging, in the management of AKI. The use of gadolinium in MR imaging may exacerbate renal impairment and cause nephrogenic systemic fibrosis. Therefore, dynamic contrast-enhanced MR imaging will not be discussed in this paper.
Collapse
Affiliation(s)
- Hai Ying Zhou
- Sichuan Key Laboratory of Medical Imaging, Department of Radiology, Affiliated Hospital of North Sichuan Medical College, 63 Wenhua Road, Shunqing District, Nanchong, Sichuan 637000, China
| | - Tian Wu Chen
- Sichuan Key Laboratory of Medical Imaging, Department of Radiology, Affiliated Hospital of North Sichuan Medical College, 63 Wenhua Road, Shunqing District, Nanchong, Sichuan 637000, China
| | - Xiao Ming Zhang
- Sichuan Key Laboratory of Medical Imaging, Department of Radiology, Affiliated Hospital of North Sichuan Medical College, 63 Wenhua Road, Shunqing District, Nanchong, Sichuan 637000, China
| |
Collapse
|
40
|
Klotz S, Pallavi P, Tsagogiorgas C, Zimmer F, Zöllner FG, Binzen U, Greffrath W, Treede RD, Walter J, Harmsen MC, Krämer BK, Hafner M, Yard BA, Hoeger S. N-octanoyl dopamine treatment exerts renoprotective properties in acute kidney injury but not in renal allograft recipients. Nephrol Dial Transplant 2015; 31:564-73. [DOI: 10.1093/ndt/gfv363] [Citation(s) in RCA: 9] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/27/2015] [Accepted: 09/17/2015] [Indexed: 12/26/2022] Open
|
41
|
Using intravoxel incoherent motion MR imaging to study the renal pathophysiological process of contrast-induced acute kidney injury in rats: Comparison with conventional DWI and arterial spin labelling. Eur Radiol 2015; 26:1597-605. [DOI: 10.1007/s00330-015-3990-y] [Citation(s) in RCA: 36] [Impact Index Per Article: 4.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/23/2015] [Revised: 06/23/2015] [Accepted: 08/31/2015] [Indexed: 01/01/2023]
|
42
|
Chen B, Zhao K, Li B, Cai W, Wang X, Zhang J, Fang J. High temporal resolution dynamic contrast-enhanced MRI using compressed sensing-combined sequence in quantitative renal perfusion measurement. Magn Reson Imaging 2015; 33:962-9. [PMID: 25967586 DOI: 10.1016/j.mri.2015.05.004] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/02/2014] [Accepted: 05/06/2015] [Indexed: 10/23/2022]
Abstract
PURPOSE To demonstrate the feasibility of the improved temporal resolution by using compressed sensing (CS) combined imaging sequence in dynamic contrast-enhanced MRI (DCE-MRI) of kidney, and investigate its quantitative effects on renal perfusion measurements. MATERIALS AND METHODS Ten rabbits were included in the accelerated scans with a CS-combined 3D pulse sequence. To evaluate the image quality, the signal-to-noise ratio (SNR) and contrast-to-noise ratio (CNR) were compared between the proposed CS strategy and the conventional full sampling method. Moreover, renal perfusion was estimated by using the separable compartmental model in both CS simulation and realistic CS acquisitions. RESULTS The CS method showed DCE-MRI images with improved temporal resolution and acceptable image contrast, while presenting significantly higher SNR than the fully sampled images (p<.01) at 2-, 3- and 4-X acceleration. In quantitative measurements, renal perfusion results were in good agreement with the fully sampled one (concordance correlation coefficient=0.95, 0.91, 0.88) at 2-, 3- and 4-X acceleration in CS simulation. Moreover, in realistic acquisitions, the estimated perfusion by the separable compartmental model exhibited no significant differences (p>.05) between each CS-accelerated acquisition and the full sampling method. CONCLUSION The CS-combined 3D sequence could improve the temporal resolution for DCE-MRI in kidney while yielding diagnostically acceptable image quality, and it could provide effective measurements of renal perfusion.
Collapse
Affiliation(s)
- Bin Chen
- Academy for Advanced Interdisciplinary Studies, Peking University, 100871, Beijing, China
| | - Kai Zhao
- Dept. of Radiology, Peking University First Hospital, 100034, Beijing, China
| | - Bo Li
- College of Engineering, Peking University, 100871, Beijing, China
| | - Wenchao Cai
- Dept. of Radiology, Peking University First Hospital, 100034, Beijing, China
| | - Xiaoying Wang
- Academy for Advanced Interdisciplinary Studies, Peking University, 100871, Beijing, China; Dept. of Radiology, Peking University First Hospital, 100034, Beijing, China
| | - Jue Zhang
- Academy for Advanced Interdisciplinary Studies, Peking University, 100871, Beijing, China; College of Engineering, Peking University, 100871, Beijing, China.
| | - Jing Fang
- Academy for Advanced Interdisciplinary Studies, Peking University, 100871, Beijing, China; College of Engineering, Peking University, 100871, Beijing, China
| |
Collapse
|
43
|
Prevost VH, Girard OM, Callot V, Cozzone PJ, Duhamel G. Fast imaging strategies for mouse kidney perfusion measurement with pseudocontinuous arterial spin labeling (pCASL) at ultra high magnetic field (11.75 tesla). J Magn Reson Imaging 2015; 42:999-1008. [DOI: 10.1002/jmri.24874] [Citation(s) in RCA: 10] [Impact Index Per Article: 1.1] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/16/2014] [Accepted: 02/04/2015] [Indexed: 12/28/2022] Open
Affiliation(s)
- Valentin H Prevost
- Aix-Marseille Université, CNRS Centre de Résonance Magnétique Biologique et Médicale, UMR 7339, Marseille, France
| | - Olivier M Girard
- Aix-Marseille Université, CNRS Centre de Résonance Magnétique Biologique et Médicale, UMR 7339, Marseille, France
| | - Virginie Callot
- Aix-Marseille Université, CNRS Centre de Résonance Magnétique Biologique et Médicale, UMR 7339, Marseille, France
| | - Patrick J Cozzone
- Aix-Marseille Université, CNRS Centre de Résonance Magnétique Biologique et Médicale, UMR 7339, Marseille, France
| | - Guillaume Duhamel
- Aix-Marseille Université, CNRS Centre de Résonance Magnétique Biologique et Médicale, UMR 7339, Marseille, France
| |
Collapse
|
44
|
Zöllner FG, Kalayciyan R, Chacón-Caldera J, Zimmer F, Schad LR. Pre-clinical functional Magnetic Resonance Imaging part I: The kidney. Z Med Phys 2014; 24:286-306. [DOI: 10.1016/j.zemedi.2014.05.002] [Citation(s) in RCA: 10] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/19/2013] [Revised: 05/19/2014] [Accepted: 05/19/2014] [Indexed: 01/10/2023]
|
45
|
Velroyen A, Bech M, Zanette I, Schwarz J, Rack A, Tympner C, Herrler T, Staab-Weijnitz C, Braunagel M, Reiser M, Bamberg F, Pfeiffer F, Notohamiprodjo M. X-ray phase-contrast tomography of renal ischemia-reperfusion damage. PLoS One 2014; 9:e109562. [PMID: 25299243 PMCID: PMC4192129 DOI: 10.1371/journal.pone.0109562] [Citation(s) in RCA: 20] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/15/2014] [Accepted: 09/02/2014] [Indexed: 01/28/2023] Open
Abstract
Purpose The aim of the study was to investigate microstructural changes occurring in unilateral renal ischemia-reperfusion injury in a murine animal model using synchrotron radiation. Material and Methods The effects of renal ischemia-reperfusion were investigated in a murine animal model of unilateral ischemia. Kidney samples were harvested on day 18. Grating-Based Phase-Contrast Imaging (GB-PCI) of the paraffin-embedded kidney samples was performed at a Synchrotron Radiation Facility (beam energy of 19 keV). To obtain phase information, a two-grating Talbot interferometer was used applying the phase stepping technique. The imaging system provided an effective pixel size of 7.5 µm. The resulting attenuation and differential phase projections were tomographically reconstructed using filtered back-projection. Semi-automated segmentation and volumetry and correlation to histopathology were performed. Results GB-PCI provided good discrimination of the cortex, outer and inner medulla in non-ischemic control kidneys. Post-ischemic kidneys showed a reduced compartmental differentiation, particularly of the outer stripe of the outer medulla, which could not be differentiated from the inner stripe. Compared to the contralateral kidney, after ischemia a volume loss was detected, while the inner medulla mainly retained its volume (ratio 0.94). Post-ischemic kidneys exhibited severe tissue damage as evidenced by tubular atrophy and dilatation, moderate inflammatory infiltration, loss of brush borders and tubular protein cylinders. Conclusion In conclusion GB-PCI with synchrotron radiation allows for non-destructive microstructural assessment of parenchymal kidney disease and vessel architecture. If translation to lab-based approaches generates sufficient density resolution, and with a time-optimized image analysis protocol, GB-PCI may ultimately serve as a non-invasive, non-enhanced alternative for imaging of pathological changes of the kidney.
Collapse
Affiliation(s)
- Astrid Velroyen
- Chair of Biomedical Physics, Department of Physics (E17), Munich, Bavaria, Germany
| | - Martin Bech
- Chair of Biomedical Physics, Department of Physics (E17), Munich, Bavaria, Germany
- Medical Radiation Physics, Lund University, Lund, Sweden
| | - Irene Zanette
- Chair of Biomedical Physics, Department of Physics (E17), Munich, Bavaria, Germany
| | - Jolanda Schwarz
- Chair of Biomedical Physics, Department of Physics (E17), Munich, Bavaria, Germany
| | - Alexander Rack
- European Synchrotron Radiation Facility, Grenoble, France
| | - Christiane Tympner
- Institute of Pathology, Ludwig-Maximilians-University Munich, Munich, Germany
| | - Tanja Herrler
- Department of General, Trauma, Hand, and Plastic Surgery, Ludwig-Maximilians-University Hospital Munich, Munich, Germany
| | - Claudia Staab-Weijnitz
- Institute for Clinical Radiology, University Hospitals Munich, Munich, Germany
- Comprehensive Pneumology Center, University Hospital, Ludwig-Maximilians-University and Helmholtz Zentrum Munich, Munich, Germany
| | - Margarita Braunagel
- Institute for Clinical Radiology, University Hospitals Munich, Munich, Germany
| | - Maximilian Reiser
- Institute for Clinical Radiology, University Hospitals Munich, Munich, Germany
| | - Fabian Bamberg
- Institute for Clinical Radiology, University Hospitals Munich, Munich, Germany
- Department of Radiology, University Hospital Tuebingen, Tuebingen, Germany
| | - Franz Pfeiffer
- Chair of Biomedical Physics, Department of Physics (E17), Munich, Bavaria, Germany
| | - Mike Notohamiprodjo
- Institute for Clinical Radiology, University Hospitals Munich, Munich, Germany
- Department of Radiology, University Hospital Tuebingen, Tuebingen, Germany
- * E-mail:
| |
Collapse
|
46
|
Rong S, Hueper K, Kirsch T, Greite R, Klemann C, Mengel M, Meier M, Menne J, Leitges M, Susnik N, Meier M, Haller H, Shushakova N, Gueler F. Renal PKC-ε deficiency attenuates acute kidney injury and ischemic allograft injury via TNF-α-dependent inhibition of apoptosis and inflammation. Am J Physiol Renal Physiol 2014; 307:F718-26. [DOI: 10.1152/ajprenal.00372.2013] [Citation(s) in RCA: 28] [Impact Index Per Article: 2.8] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/22/2022] Open
Abstract
Acute kidney injury (AKI) increases the risk of morbidity and mortality after major surgery and transplantation. We investigated the effect of PKC-ε deficiency on AKI and ischemic allograft damage after kidney transplantation. PKC-ε-deficient and wild type (WT) control mice were subjected to 35 min of renal pedicle clamping to induce AKI. PKC-ε deficiency was associated with a marked improvement in survival and an attenuated loss of kidney function. Furthermore, functional MRI experiments revealed better renal perfusion in PKC-ε-deficient mice than in WT mice one day after IRI. Acute tubular necrosis and neutrophil infiltration were markedly reduced in PKC-ε-deficient mice. To determine whether this resistance to ischemia-reperfusion injury resulted from changes in local renal cells or infiltrating leukocytes, we studied a life-supporting renal transplant model of ischemic graft injury. We transplanted kidneys from H2b PKC-ε-deficient mice (129/SV) and their corresponding WT littermates into major histocompatibility complex-incompatible H2d recipients (BALB/c) and induced ischemic graft injury by prolonged cold ischemia time. Recipients of WT allografts developed severe renal failure and died within 10 days of transplantation. Recipients of PKC-ε-deficient allografts had better renal function and survival; they had less generation of ROS and upregulation of proinflammatory proteins (i.e., ICAM-1, inducible nitric oxide synthase, and TNF-α) and showed less tubular epithelial cell apoptosis and inflammation in their allografts. These data suggest that local renal PKC-ε expression mediates proapoptotic and proinflammatory signaling and that an inhibitor of PKC-ε signaling could be used to prevent hypoxia-induced AKI.
Collapse
Affiliation(s)
- Song Rong
- Department of Nephrology, Hannover Medical School, Hannover, Germany
- The Transplantation Center, Affiliated Hospital, Zunyi Medical College, Zunyi, China
| | - Katja Hueper
- Institute for Diagnostic and Interventional Radiology, Medical School Hannover, Hannover, Germany
| | - Torsten Kirsch
- Department of Nephrology, Hannover Medical School, Hannover, Germany
| | - Robert Greite
- Department of Nephrology, Hannover Medical School, Hannover, Germany
| | - Christian Klemann
- Centre for Paediatrics and Adolescent Medicine, Department of Pediatric Surgery, Hannover Medical School, Hannover, Germany
| | - Michael Mengel
- Department of Laboratory Medicine and Pathology, University of Alberta, Edmonton, Canada
| | - Matthias Meier
- Department of Nephrology, Hannover Medical School, Hannover, Germany
| | - Jan Menne
- Department of Nephrology, Hannover Medical School, Hannover, Germany
- Phenos GmbH, Hannover, Germany
| | - Michael Leitges
- Department of Nephrology, Hannover Medical School, Hannover, Germany
- The Biotechnology Centre of Oslo, University of Oslo, Oslo, Norway
| | - Nathan Susnik
- Department of Nephrology, Hannover Medical School, Hannover, Germany
| | - Martin Meier
- Imaging Center, Institute for Animal Science, Medical School Hannover, Hannover, Germany; and
| | - Hermann Haller
- Department of Nephrology, Hannover Medical School, Hannover, Germany
| | - Nelli Shushakova
- Department of Nephrology, Hannover Medical School, Hannover, Germany
- Phenos GmbH, Hannover, Germany
| | - Faikah Gueler
- Department of Nephrology, Hannover Medical School, Hannover, Germany
| |
Collapse
|
47
|
Chen B, Zhang Y, Song X, Wang X, Zhang J, Fang J. Quantitative estimation of renal function with dynamic contrast-enhanced MRI using a modified two-compartment model. PLoS One 2014; 9:e105087. [PMID: 25141138 PMCID: PMC4139329 DOI: 10.1371/journal.pone.0105087] [Citation(s) in RCA: 6] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/24/2014] [Accepted: 07/19/2014] [Indexed: 11/18/2022] Open
Abstract
OBJECTIVE To establish a simple two-compartment model for glomerular filtration rate (GFR) and renal plasma flow (RPF) estimations by dynamic contrast-enhanced magnetic resonance imaging (DCE-MRI). MATERIALS AND METHODS A total of eight New Zealand white rabbits were included in DCE-MRI. The two-compartment model was modified with the impulse residue function in this study. First, the reliability of GFR measurement of the proposed model was compared with other published models in Monte Carlo simulation at different noise levels. Then, functional parameters were estimated in six healthy rabbits to test the feasibility of the new model. Moreover, in order to investigate its validity of GFR estimation, two rabbits underwent acute ischemia surgical procedure in unilateral kidney before DCE-MRI, and pixel-wise measurements were implemented to detect the cortical GFR alterations between normal and abnormal kidneys. RESULTS The lowest variability of GFR and RPF measurements were found in the proposed model in the comparison. Mean GFR was 3.03±1.1 ml/min and mean RPF was 2.64±0.5 ml/g/min in normal animals, which were in good agreement with the published values. Moreover, large GFR decline was found in dysfunction kidneys comparing to the contralateral control group. CONCLUSION Results in our study demonstrate that measurement of renal kinetic parameters based on the proposed model is feasible and it has the ability to discriminate GFR changes in healthy and diseased kidneys.
Collapse
Affiliation(s)
- Bin Chen
- Academy for Advanced Interdisciplinary Studies, Peking University, Beijing, China
| | - Yudong Zhang
- Department of Radiology, Peking University First Hospital, Beijing, China
| | - Xiaojian Song
- Academy for Advanced Interdisciplinary Studies, Peking University, Beijing, China
- Department of Electrical Engineering, Chengdu University of Information Technology, Chengdu, Sichuan, China
| | - Xiaoying Wang
- Academy for Advanced Interdisciplinary Studies, Peking University, Beijing, China
- Department of Radiology, Peking University First Hospital, Beijing, China
- * E-mail: (XW); (JZ)
| | - Jue Zhang
- Academy for Advanced Interdisciplinary Studies, Peking University, Beijing, China
- College of Engineering, Peking University, Beijing, China
- * E-mail: (XW); (JZ)
| | - Jing Fang
- Academy for Advanced Interdisciplinary Studies, Peking University, Beijing, China
- College of Engineering, Peking University, Beijing, China
| |
Collapse
|
48
|
Tan H, Thacker J, Franklin T, Prasad PV. Sensitivity of arterial spin labeling perfusion MRI to pharmacologically induced perfusion changes in rat kidneys. J Magn Reson Imaging 2014; 41:1124-8. [PMID: 24796852 DOI: 10.1002/jmri.24645] [Citation(s) in RCA: 12] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/03/2014] [Accepted: 03/21/2014] [Indexed: 12/13/2022] Open
Abstract
PURPOSE To investigate whether arterial spin labeling (ASL) MRI is sensitive to changes by pharmacologically induced vasodilation and vasoconstriction in rat kidneys. MATERIALS AND METHODS Changes in renal cortical blood flow in seven rats were induced by adenosine infusion (vasodilation) and L-NAME injection (vasoconstriction). All imaging studies were performed on a 3 Tesla scanner using a FAIR-TrueFISP sequence for the ASL implementation. The acquisition time for each ASL scan was 6 min. Cortical perfusion rates were calculated using regions of interest analysis, and the differences in perfusion rates during baseline, vasodilation, and vasoconstriction were compared and assessed for statistical significance. RESULTS Compared with the baseline, an average of 94 mL/100 g/min increase and 157 mL/100 g/min decrease in cortical perfusion was observed following adenosine infusion and L-NAME administration, respectively. The changes in cortical perfusion were significant between baseline and vasodilation (P < 0.05), baseline and vasoconstriction (P < 0.01), and vasodilation and vasoconstriction (P < 0.01). CONCLUSION ASL is sensitive to pharmacologically induced perfusion changes in rat kidneys at doses comparable to current use. The preliminary results suggest the feasibility of ASL for investigating renal blood flow in a variety of rodent models.
Collapse
Affiliation(s)
- Huan Tan
- Department of Surgery (Neurosurgery), University of Chicago, Chicago, Illinois, USA
| | | | | | | |
Collapse
|
49
|
Zhang JL, Morrell G, Rusinek H, Sigmund EE, Chandarana H, Lerman LO, Prasad PV, Niles D, Artz N, Fain S, Vivier PH, Cheung AK, Lee VS. New magnetic resonance imaging methods in nephrology. Kidney Int 2014; 85:768-78. [PMID: 24067433 PMCID: PMC3965662 DOI: 10.1038/ki.2013.361] [Citation(s) in RCA: 71] [Impact Index Per Article: 7.1] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/29/2013] [Revised: 07/16/2013] [Accepted: 07/17/2013] [Indexed: 02/06/2023]
Abstract
Established as a method to study anatomic changes, such as renal tumors or atherosclerotic vascular disease, magnetic resonance imaging (MRI) to interrogate renal function has only recently begun to come of age. In this review, we briefly introduce some of the most important MRI techniques for renal functional imaging, and then review current findings on their use for diagnosis and monitoring of major kidney diseases. Specific applications include renovascular disease, diabetic nephropathy, renal transplants, renal masses, acute kidney injury, and pediatric anomalies. With this review, we hope to encourage more collaboration between nephrologists and radiologists to accelerate the development and application of modern MRI tools in nephrology clinics.
Collapse
Affiliation(s)
- Jeff L Zhang
- Department of Radiology, University of Utah, Salt Lake City, Utah, USA
| | - Glen Morrell
- Department of Radiology, University of Utah, Salt Lake City, Utah, USA
| | - Henry Rusinek
- Department of Radiology, New York University, New York, New York, USA
| | - Eric E Sigmund
- Department of Radiology, New York University, New York, New York, USA
| | - Hersh Chandarana
- Department of Radiology, New York University, New York, New York, USA
| | - Lilach O Lerman
- Department of Nephrology and Hypertension, Mayo Clinic, Rochester, MN, USA
| | | | - David Niles
- Department of Medical Physics, University of Wisconsin-Madison, Madison, Wisconsin, USA
| | - Nathan Artz
- Department of Medical Physics, University of Wisconsin-Madison, Madison, Wisconsin, USA
| | - Sean Fain
- Department of Medical Physics, University of Wisconsin-Madison, Madison, Wisconsin, USA
| | | | - Alfred K Cheung
- Division of Nephrology and Hypertension, University of Utah, Salt Lake City, Utah, USA
| | - Vivian S Lee
- Department of Radiology, University of Utah, Salt Lake City, Utah, USA
| |
Collapse
|
50
|
Zöllner FG, Zimmer F, Klotz S, Hoeger S, Schad LR. Functional imaging of acute kidney injury at 3 Tesla: investigating multiple parameters using DCE-MRI and a two-compartment filtration model. Z Med Phys 2014; 25:58-65. [PMID: 24629306 DOI: 10.1016/j.zemedi.2014.01.002] [Citation(s) in RCA: 16] [Impact Index Per Article: 1.6] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/11/2013] [Revised: 01/10/2014] [Accepted: 01/10/2014] [Indexed: 11/28/2022]
Abstract
OBJECT To investigate how MR-based parameters reflect functional changes in kidneys with acute kidney injury (AKI) using dynamic contrast enhanced MRI and a two-compartment renal filtration model. MATERIALS AND METHODS MRI data of eight male Lewis rats were analyzed retrospectively. Five animals were subjected to AKI, three native rats served as control. All animals underwent perfusion imaging by dynamic contrast-enhanced MRI. Renal blood volume, glomerular filtration rate (GFR) as well as plasma and tubular mean transit times were estimated from regions-of-interest drawn in the renal cortex. Differences between healthy kidneys and kidneys subjected to AKI were analyzed using a paired t-test. RESULTS Significant differences between ischemic and healthy kidneys could only be detected for the glomerular filtration rate. For all other calculated parameters, differences were present, however not significant. In rats with AKI, average single kidney GFR was 0.66 ± 0.37 ml/min for contralateral and 0.26 ± 0.12 ml/ min for diseased kidneys (P = 0.0254). For the healthy control group, the average GFR was 0.39 ± 0.06 ml/min and 0.41 ± 0.11 ml/min, respectively. Differences between diseased kidneys of AKI rats and ipsilateral kidneys of the healthy control group were significant (P = 0.0381). CONCLUSION Significant differences of functional parameters reflecting damage of the renal tissue of kidneys with AKI compared to the contralateral, healthy kidneys could only be detected by GFR. GFR might be a useful parameter that allows for a spatially resolved detection of abnormal changes of renal tissue by AKI.
Collapse
Affiliation(s)
- Frank G Zöllner
- Computer Assisted Clinical Medicine, Medical Faculty Mannheim, Heidelberg University, Mannheim, Germany.
| | - Fabian Zimmer
- Computer Assisted Clinical Medicine, Medical Faculty Mannheim, Heidelberg University, Mannheim, Germany
| | - Sarah Klotz
- Department of Medicine V, University Medical Centre Mannheim, Heidelberg University, Mannheim, Germany
| | - Simone Hoeger
- Department of Medicine V, University Medical Centre Mannheim, Heidelberg University, Mannheim, Germany
| | - Lothar R Schad
- Computer Assisted Clinical Medicine, Medical Faculty Mannheim, Heidelberg University, Mannheim, Germany
| |
Collapse
|