1
|
Li B, Ni J, Chen F, Lu F, Zhang L, Wu W, Zhang Z. Evaluation of three-dimensional dual-energy CT cholangiopancreatography image quality in patients with pancreatobiliary dilatation: Comparison with conventional single-energy CT. Eur J Radiol Open 2023; 11:100537. [PMID: 37942123 PMCID: PMC10628547 DOI: 10.1016/j.ejro.2023.100537] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/14/2023] [Revised: 10/18/2023] [Accepted: 10/24/2023] [Indexed: 11/10/2023] Open
Abstract
Objective This study aimed to evaluate three-dimensional (3D) negative-contrast CT cholangiopancreatography (nCTCP) image quality using dual-energy CT (DECT) with iterative reconstruction (IR) technique in patients with pancreatobiliary dilatation compared with single-energy CT (SECT). Methods Of the patients, 67 and 56 underwent conventional SECT (SECT set) and DECT with IR technique (DECT set), respectively. All patients were retrospectively analyzed during the portal phase to compare objective image quality and other data including patient demographics, hepatic and pancreatic parenchymal enhancement, noise, and attenuation difference (AD) between dilated ducts and enhanced hepatic parenchyma, signal-to-noise ratio (SNR), contrast-to-noise ratio (CNR), and CT volume dose index (CTDIvol). Two radiologists used the five-point Likert scale to evaluate the subjective image quality of 3D nCTCP regarding image noise, sharpness of dilated ducts, and overall image quality. Statistical analyses used the Mann-Whitney U test. Results No significant difference in patient demographics in either CT set was showed during objective evaluation (p > 0.05). However, higher hepatic and pancreatic parenchymal enhancement, AD, SNR, and CNR and lower hepatic and pancreatic noise (p < 0.005) as well as CTDIvol (p = 0.005) on DECT than on SECT were observed. Higher mean grades on DECT than on SECT were showed for image noise (4.65 vs 3.92), sharpness of dilated ducts (4.52 vs 3.94), and overall image quality (4.45 vs 3.91; p < 0.001), respectively during subjective evaluation. Conclusion A higher overall image quality and lower radiation dose on 3D nCTCP can be obtained by DECT with IR technique than with conventional SECT in patients with pancreatobiliary dilatation.
Collapse
Affiliation(s)
- Bin Li
- Department of Radiology, Wuxi No.2 People’s Hospital, 68 Zhong shan Rd., Wuxi 214002, Jiangsu, PR China
| | - JianMing Ni
- Department of Radiology, Wuxi No.2 People’s Hospital, 68 Zhong shan Rd., Wuxi 214002, Jiangsu, PR China
| | - FangMing Chen
- Department of Radiology, Wuxi No.2 People’s Hospital, 68 Zhong shan Rd., Wuxi 214002, Jiangsu, PR China
| | - FengQi Lu
- Department of Radiology, Wuxi No.2 People’s Hospital, 68 Zhong shan Rd., Wuxi 214002, Jiangsu, PR China
| | - Lei Zhang
- Department of Radiology, Wuxi No.2 People’s Hospital, 68 Zhong shan Rd., Wuxi 214002, Jiangsu, PR China
| | - WenJuan Wu
- Department of Radiology, Wuxi No.2 People’s Hospital, 68 Zhong shan Rd., Wuxi 214002, Jiangsu, PR China
| | - ZhuiYang Zhang
- Department of Radiology, Wuxi No.2 People’s Hospital, 68 Zhong shan Rd., Wuxi 214002, Jiangsu, PR China
| |
Collapse
|
2
|
Hu WT, Chen W, Zhou M, Fan J, Yan F, Liu B, Lu FY, Chen R, Guo Y, Yang W. Quantitative analyzes of the variability in airways via four-dimensional dynamic ventilation CT in patients with chronic obstructive pulmonary disease: correlation with spirometry data and severity of airflow limitation. J Thorac Dis 2023; 15:4775-4786. [PMID: 37868900 PMCID: PMC10586961 DOI: 10.21037/jtd-23-573] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/05/2023] [Accepted: 08/04/2023] [Indexed: 10/24/2023]
Abstract
Background In chronic obstructive pulmonary disease (COPD) patients, the diagnosis and assessment of disease severity are mainly based on spirometry, which may lead to misjudgments due to poor patient compliance. Thoracic four-dimensional dynamic ventilation computed tomography (4D-CT) provides more airway data approximating true physiological function than conventional CT. We aimed to determine dynamic changes in airways to elucidate the pathological mechanism underlying COPD and predict the severity of airflow limitation in patients. Methods Forty-two COPD patients underwent 4D-CT and spirometry. The minimum lumen diameter changed with the breathing cycle in 4th-generation airways and was continuously measured in the apical (RB1), lateral (RB4) and posterior basal segments (RB10) of the right lung. The minimum lumen diameter in the peak inspiration and peak expiration as well as the peak expiratory/peak inspiratory ratio (E/I ratio), and dynamic coefficient of variance (CV) were calculated. Results Correlations of FEV1% with the CV of minimum lumen diameter in RB1 (ρ=-0.473, P=0.002) and in RB10 (ρ=-0.480, P=0.005) were observed, suggesting that the dynamic variability in 4th-generation airways was associated with airflow limitation in COPD patients. The CV of the minimum lumen diameter in RB1 significantly differed between the GOLD I + II and GOLD III + IV groups {8.59 [interquartile range (IQR), 6.63-14.86] vs. 14.64 (10.65-25.88), respectively; P=0.016}, suggesting that the dynamic CV in RB1 increased significantly in the GOLD III + IV group, which had worse pulmonary ventilation function. Based on the receiver operating characteristic (ROC) curve analysis, CV-RB1 predicted FEV1% <50% with an optimal cut-off of 9.43% [sensitivity 85.7%, specificity 57.1%, area under the curve (AUC) 0.717]. Conclusions 4D-CT might be an available method to help diagnose and evaluate the severity of COPD.
Collapse
Affiliation(s)
- Wei-Ting Hu
- Department of Pulmonary and Critical Care Medicine, Ruijin Hospital, Shanghai Jiao Tong University School of Medicine, Shanghai, China
- Institute of Respiratory Diseases, Shanghai Jiao Tong University School of Medicine, Shanghai, China
- Shanghai Key Laboratory of Emergency Prevention, Diagnosis and Treatment of Respiratory Infectious Diseases, Shanghai, China
| | - Wei Chen
- Department of Pulmonary and Critical Care Medicine, Ruijin Hospital, Shanghai Jiao Tong University School of Medicine, Shanghai, China
- Institute of Respiratory Diseases, Shanghai Jiao Tong University School of Medicine, Shanghai, China
- Shanghai Key Laboratory of Emergency Prevention, Diagnosis and Treatment of Respiratory Infectious Diseases, Shanghai, China
| | - Min Zhou
- Department of Pulmonary and Critical Care Medicine, Ruijin Hospital, Shanghai Jiao Tong University School of Medicine, Shanghai, China
- Institute of Respiratory Diseases, Shanghai Jiao Tong University School of Medicine, Shanghai, China
- Shanghai Key Laboratory of Emergency Prevention, Diagnosis and Treatment of Respiratory Infectious Diseases, Shanghai, China
| | - Jing Fan
- Department of Radiology, Ruijin Hospital, Shanghai Jiao Tong University School of Medicine, Shanghai, China
| | - Fuhua Yan
- Department of Radiology, Ruijin Hospital, Shanghai Jiao Tong University School of Medicine, Shanghai, China
| | - Bing Liu
- Department of Pulmonary and Critical Care Medicine, Ruijin Hospital, Shanghai Jiao Tong University School of Medicine, Shanghai, China
- Institute of Respiratory Diseases, Shanghai Jiao Tong University School of Medicine, Shanghai, China
- Shanghai Key Laboratory of Emergency Prevention, Diagnosis and Treatment of Respiratory Infectious Diseases, Shanghai, China
| | - Fang-Ying Lu
- Department of Pulmonary and Critical Care Medicine, Ruijin Hospital, Shanghai Jiao Tong University School of Medicine, Shanghai, China
- Institute of Respiratory Diseases, Shanghai Jiao Tong University School of Medicine, Shanghai, China
- Shanghai Key Laboratory of Emergency Prevention, Diagnosis and Treatment of Respiratory Infectious Diseases, Shanghai, China
| | - Rong Chen
- Department of Pulmonary and Critical Care Medicine, Ruijin Hospital, Shanghai Jiao Tong University School of Medicine, Shanghai, China
- Institute of Respiratory Diseases, Shanghai Jiao Tong University School of Medicine, Shanghai, China
- Shanghai Key Laboratory of Emergency Prevention, Diagnosis and Treatment of Respiratory Infectious Diseases, Shanghai, China
| | - Yi Guo
- Department of Pulmonary and Critical Care Medicine, Ruijin Hospital, Shanghai Jiao Tong University School of Medicine, Shanghai, China
- Institute of Respiratory Diseases, Shanghai Jiao Tong University School of Medicine, Shanghai, China
- Shanghai Key Laboratory of Emergency Prevention, Diagnosis and Treatment of Respiratory Infectious Diseases, Shanghai, China
| | - Wenjie Yang
- Department of Radiology, Ruijin Hospital, Shanghai Jiao Tong University School of Medicine, Shanghai, China
| |
Collapse
|
3
|
Ohno Y, Ozawa Y, Nagata H, Bando S, Cong S, Takahashi T, Oshima Y, Hamabuchi N, Matsuyama T, Ueda T, Yoshikawa T, Takenaka D, Toyama H. Area-Detector Computed Tomography for Pulmonary Functional Imaging. Diagnostics (Basel) 2023; 13:2518. [PMID: 37568881 PMCID: PMC10416899 DOI: 10.3390/diagnostics13152518] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/05/2023] [Revised: 07/22/2023] [Accepted: 07/25/2023] [Indexed: 08/13/2023] Open
Abstract
An area-detector CT (ADCT) has a 320-detector row and can obtain isotropic volume data without helical scanning within an area of nearly 160 mm. The actual-perfusion CT data within this area can, thus, be obtained by means of continuous dynamic scanning for the qualitative or quantitative evaluation of regional perfusion within nodules, lymph nodes, or tumors. Moreover, this system can obtain CT data with not only helical but also step-and-shoot or wide-volume scanning for body CT imaging. ADCT also has the potential to use dual-energy CT and subtraction CT to enable contrast-enhanced visualization by means of not only iodine but also xenon or krypton for functional evaluations. Therefore, systems using ADCT may be able to function as a pulmonary functional imaging tool. This review is intended to help the reader understand, with study results published during the last a few decades, the basic or clinical evidence about (1) newly applied reconstruction methods for radiation dose reduction for functional ADCT, (2) morphology-based pulmonary functional imaging, (3) pulmonary perfusion evaluation, (4) ventilation assessment, and (5) biomechanical evaluation.
Collapse
Affiliation(s)
- Yoshiharu Ohno
- Department of Diagnostic Radiology, Fujita Health University School of Medicine, Toyoake 470-1192, Aichi, Japan
- Joint Research Laboratory of Advanced Medical Imaging, Fujita Health University School of Medicine, Toyoake 470-1192, Aichi, Japan;
| | - Yoshiyuki Ozawa
- Department of Radiology, Fujita Health University School of Medicine, Toyoake 470-1192, Aichi, Japan; (Y.O.)
| | - Hiroyuki Nagata
- Joint Research Laboratory of Advanced Medical Imaging, Fujita Health University School of Medicine, Toyoake 470-1192, Aichi, Japan;
| | - Shuji Bando
- Department of Radiology, Fujita Health University School of Medicine, Toyoake 470-1192, Aichi, Japan; (Y.O.)
| | - Shang Cong
- Department of Radiology, Fujita Health University School of Medicine, Toyoake 470-1192, Aichi, Japan; (Y.O.)
| | - Tomoki Takahashi
- Department of Radiology, Fujita Health University School of Medicine, Toyoake 470-1192, Aichi, Japan; (Y.O.)
| | - Yuka Oshima
- Department of Radiology, Fujita Health University School of Medicine, Toyoake 470-1192, Aichi, Japan; (Y.O.)
| | - Nayu Hamabuchi
- Department of Radiology, Fujita Health University School of Medicine, Toyoake 470-1192, Aichi, Japan; (Y.O.)
| | - Takahiro Matsuyama
- Department of Radiology, Fujita Health University School of Medicine, Toyoake 470-1192, Aichi, Japan; (Y.O.)
| | - Takahiro Ueda
- Department of Radiology, Fujita Health University School of Medicine, Toyoake 470-1192, Aichi, Japan; (Y.O.)
| | - Takeshi Yoshikawa
- Department of Diagnostic Radiology, Hyogo Cancer Center, Akashi 673-0021, Hyogo, Japan
| | - Daisuke Takenaka
- Department of Diagnostic Radiology, Hyogo Cancer Center, Akashi 673-0021, Hyogo, Japan
| | - Hiroshi Toyama
- Department of Radiology, Fujita Health University School of Medicine, Toyoake 470-1192, Aichi, Japan; (Y.O.)
| |
Collapse
|
4
|
Hoyoshi K, Ohmura T, Kayano S, Goto M, Muramatsu S, Homma N. [A Review of Current Knowledge for X-ray Energy in CT: Practical Guide for CT Technologist]. Nihon Hoshasen Gijutsu Gakkai Zasshi 2022; 78:449-463. [PMID: 35400711 DOI: 10.6009/jjrt.2022-1238] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/11/2022]
Abstract
In computed tomography (CT) systems, the optimal X-ray energy in imaging depends on the material composition and the subject size. Among the parameters related to the X-ray energy, we can arbitrarily change only the tube voltage. For years, the tube voltage has often been set at 120 kVp. However, since about 2000, there has been an increasing interest in reducing radiation dose, and it has led to the publication of various reports on low tube voltage. Furthermore, with the spread of dual-energy CT, virtual monochromatic X-ray images are widely used since the contrast can be adjusted by selecting the optional energy. Therefore, because of the renewed interest in X-ray energy in CT imaging, the issue of energy and imaging needs to be summarized. In this article, we describe the basics of physical characteristics of X-ray attenuation with materials and its influence on the process of CT imaging. Moreover, the relationship between X-ray energy and CT imaging is discussed for clinical applications.
Collapse
Affiliation(s)
- Kazutaka Hoyoshi
- Department of Radiology, Yamagata University Hospital.,Department of Radiological Imaging and Informatics, Tohoku University Graduate School of Medicine
| | - Tomomi Ohmura
- Department of Radiology and Nuclear Medicine, Akita Cerebrospinal and Cardiovascular Center
| | - Shingo Kayano
- Department of Radiological Technology, Tohoku University Hospital
| | - Mitsunori Goto
- Department of Radiological Technology, Miyagi Cancer Center (Current address: Department of Radiology, Fujita Health University Hospital)
| | | | - Noriyasu Homma
- Department of Radiological Imaging and Informatics, Tohoku University Graduate School of Medicine
| |
Collapse
|
5
|
Detectability of Head and Neck Cancer via New Computed Tomography Reconstruction Tools including Iterative Reconstruction and Metal Artifact Reduction. Diagnostics (Basel) 2021; 11:diagnostics11112154. [PMID: 34829501 PMCID: PMC8620183 DOI: 10.3390/diagnostics11112154] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/30/2021] [Revised: 11/07/2021] [Accepted: 11/10/2021] [Indexed: 12/24/2022] Open
Abstract
State-of-the-art technology in Computed Tomography (CT) includes iterative reconstruction algorithms (IR) and metal artefact reduction (MAR) techniques. The objective of the study is to show the benefits of this technology for the detection of primary and recurrent head and neck cancer. A total of 131 patients underwent contrast-enhanced CT for diagnosis of primary and recurrent Head and Neck cancer; 110 patients were included. All scans were reconstructed using iterative reconstruction, and metal artifact reduction was applied when indicated. Tumor detectability was evaluated dichotomously. Histopathological findings were used as a standard of reference. Data were analyzed retrospectively, statistics was performed through diagnostic test characteristics. State-of-the-art Head and Neck CT showed a sensitivity of 0.83 (95% CI; 0.61–0.95) with 0.93 specificity (95% CI; 0.84–0.98) for primary tumor detection. Recurrent tumors were identified with a 0.94 sensitivity (95% CI; 0.71–0.99) and 0.93 specificity (95% CI; 0.84–0.98) in this study. Conclusion: State-of-the-art reconstruction tools improve the diagnostic quality of Head and Neck CT, especially for recurrent tumor detection, compared with data published for standard CT. IR and MAR are easily implemented in routine clinical settings and improve image evaluation by reducing artifacts and image noise while lowering radiation exposure.
Collapse
|
6
|
Usefulness of Model-Based Iterative Reconstruction in Brain CT as Compared With Hybrid Iterative Reconstruction. J Comput Assist Tomogr 2021; 45:600-605. [PMID: 34176874 DOI: 10.1097/rct.0000000000001171] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/25/2022]
Abstract
OBJECTIVE The aim of this study was to compare the contrast of gray to white matter between forward-projected model-based iterative reconstruction solution (FIRST) and hybrid iterative reconstruction (IR) by measuring computed tomography value of brain parenchyma. METHODS Computed tomography values of the gray and white matter in 15 areas of 21 patients (7 males, 14 females; average age, 49.5 ± 10.7 years) were measured and compared between FIRST and hybrid IR with filtered back projection (FBP) using 2 different reconstruction kernels FC21 and FC26. RESULTS The ratio of gray to white matter obtained using FIRST (1.25 ± 0.08) was significantly higher than that obtained using FBP with both kernel FC21 (1.13 ± 0.03) and kernel FC26 (1.22 ± 0.06). CONCLUSIONS FIRST increases the contrast between the gray and white matter, and decreases noise in brain computed tomography compared with FBP with hybrid IR.
Collapse
|
7
|
Tang H, Huang X, Cheng X, Yang D, Huang Y, Zhou Y. Evaluation of peri-prosthetic radiolucent lines surrounding the cementless femoral stem using digital tomosynthesis with metal artifact reduction: a cadaveric study in comparison with radiography and computed tomography. Quant Imaging Med Surg 2020; 10:1786-1800. [PMID: 32879857 DOI: 10.21037/qims-19-1018] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/20/2022]
Abstract
Background The traditional criterion for the diagnosis of implant loosening in total hip arthroplasty (THA) was once defined as a radiolucent line of >2 mm in width, based on plain radiography. Recent progress in imaging technology has allowed for the identification of complete radiolucent lines of ≤2 mm around the whole prosthesis as the basis for diagnosing component loosening in the absence of component migration. This study aimed to compare the sensitivity and specificity of digital tomosynthesis with metal artifact reduction with those of radiography and conventional computed tomography (CT) for detecting radiolucent lines of ≤2 mm surrounding cementless femoral stems of different widths. Methods The medullary canals of 4 cadaveric femurs were broached to 13 mm in diameter. Cylindrical cementless femoral stems with diameters of 9, 10, 11, 12, and 13 mm were sequentially inserted into each femur, creating 5 groups of radiolucent lines 2.0, 1.5-1.6, 1.1-1.2, 0.5-0.6, and 0 mm in diameter, respectively. Imaging by tomosynthesis, radiography, and CT was conducted for each radiolucent line model. The width information of the radiolucent line models was used as a reference standard for calculating sensitivity and specificity: observations in the group of 0 mm were used for calculating specificity, and those in the other four groups were used for sensitivity. The differences in sensitivity and specificity between the imaging methods were compared with chi-square test, and the 95% confidence intervals of improvements in the sensitivity and specificity of tomosynthesis compared with radiography and CT were calculated using mixed effects models. Results The overall sensitivity of tomosynthesis (63.3%) for detecting radiolucent lines ≤2 mm wide was significantly higher (P<0.017) than that of radiography (20.5%) and CT (50.2%), an improvement of 58.2%±3.1% (95% CI, P<0.001) and 21.7%±7.1% (95% CI, P<0.001) compared to radiography and CT, respectively. The sensitivity values for detecting radiolucent lines in all four groups by tomosynthesis and CT were significantly higher than those of radiography (P<0.017). Tomosynthesis also had significantly higher sensitivity than CT (P<0.017) in detecting radiolucent line ≤1.2 mm wide. The specificity of TMAR, radiography, and CT for detecting radiolucent lines was 87.5%, 92.5%, and 82.5%, respectively, with no significant difference (P>0.017). Conclusions Digital tomosynthesis with metal artifact reduction had significantly higher sensitivity than radiography for detecting radiolucent lines ≤2 mm wide surrounding cementless femoral stems. It also displayed higher sensitivity than CT for detecting radiolucent lines ≤1.2 mm in width. With a higher rate of detection for radiolucent lines narrower than 2 mm, tomosynthesis has the potential to improve the accuracy of early diagnosis of cementless THA stem loosening in clinical practice.
Collapse
Affiliation(s)
- Hao Tang
- Department of Orthopaedic Surgery, Beijing Jishuitan Hospital, Fourth Clinical College of Peking University, Beijing, China
| | - Xingjian Huang
- Department of Orthopaedic Surgery, Beijing Jishuitan Hospital, Fourth Clinical College of Peking University, Beijing, China
| | - Xiaoguang Cheng
- Department of Radiology, Beijing Jishuitan Hospital, Fourth Clinical College of Peking University, Beijing, China
| | - Dejin Yang
- Department of Orthopaedic Surgery, Beijing Jishuitan Hospital, Fourth Clinical College of Peking University, Beijing, China
| | - Yong Huang
- Department of Orthopaedic Surgery, Beijing Jishuitan Hospital, Fourth Clinical College of Peking University, Beijing, China
| | - Yixin Zhou
- Department of Orthopaedic Surgery, Beijing Jishuitan Hospital, Fourth Clinical College of Peking University, Beijing, China
| |
Collapse
|
8
|
Martini K, Moon JW, Revel MP, Dangeard S, Ruan C, Chassagnon G. Optimization of acquisition parameters for reduced-dose thoracic CT: A phantom study. Diagn Interv Imaging 2020; 101:269-279. [PMID: 32107196 DOI: 10.1016/j.diii.2020.01.012] [Citation(s) in RCA: 18] [Impact Index Per Article: 4.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/26/2019] [Revised: 01/23/2020] [Accepted: 01/28/2020] [Indexed: 02/06/2023]
Abstract
PURPOSE The purpose of this study was to analyze the impact of different options for reduced-dose computed tomography (CT) on image noise and visibility of pulmonary structures in order to define the best choice of parameters when performing ultra-low dose acquisitions of the chest in clinical routine. MATERIALS AND METHODS Using an anthropomorphic chest phantom, CT images were acquired at four defined low dose levels (computed tomography dose index [CTDIvol]=0.15, 0.20, 0.30 and 0.40mGy), by changing tube voltage, pitch factor, or rotation time and adapting tube current to reach the predefined CTDIvol-values. Images were reconstructed using two different levels of iteration (adaptive statistical iterative reconstruction [ASIR®]-v70% and ASIR®-v100%). Signal-to-noise ratio (SNR) as well as contrast-to-noise ratio (CNR) was calculated. Visibility of pulmonary structures (bronchi/vessels) were assessed by two readers on a 5-point-Likert scale. RESULTS Best visual image assessments and CNR/SNR were obtained with high tube voltage, while lowest scores were reached with lower pitch factor followed by high tube current. Protocols favoring lower pitch factor resulted in decreased visibility of bronchi/vessels, especially in the periphery. Decreasing radiation dose from 0.40 to 0.30mGy was not associated with a significant decrease in visual scores (P<0.05), however decreasing radiation dose from 0.30mGy to 0.15mGy was associated with a lower visibility of most of the evaluated structures (P<0.001). While image noise could be significantly reduced when ASIR®-v100% instead of ASIR®-v70% was used, the visibility-scores of pulmonary structures did not change significantly. CONCLUSION Favoring high tube voltage is the best option for reduced-dose protocols. A decrease of SNR and CNR does not necessarily go along with reduced visibility of pulmonary structures.
Collapse
Affiliation(s)
- K Martini
- Department of Radiology, Cochin Hospital, AP-HP Centre, 75014 Paris, France; Diagnostic and Interventional Radiology, University Hospital Zurich, 8008 Zurich, Switzerland
| | - J W Moon
- Department of Radiology, Cochin Hospital, AP-HP Centre, 75014 Paris, France
| | - M P Revel
- Department of Radiology, Cochin Hospital, AP-HP Centre, 75014 Paris, France; Université de Paris, Descartes-Paris 5, 75006 Paris, France
| | - S Dangeard
- Department of Radiology, Cochin Hospital, AP-HP Centre, 75014 Paris, France
| | - C Ruan
- General Electric Healthcare, 78530 Buc, France
| | - G Chassagnon
- Department of Radiology, Cochin Hospital, AP-HP Centre, 75014 Paris, France; Université de Paris, Descartes-Paris 5, 75006 Paris, France; Center for Visual Computing, École Centrale Supelec, 91190 Gif-sur-Yvette, France.
| |
Collapse
|
9
|
Richards CE, Obaid DR. Low-Dose Radiation Advances in Coronary Computed Tomography Angiography in the Diagnosis of Coronary Artery Disease. Curr Cardiol Rev 2019; 15:304-315. [PMID: 30806322 PMCID: PMC8142354 DOI: 10.2174/1573403x15666190222163737] [Citation(s) in RCA: 20] [Impact Index Per Article: 4.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 11/28/2018] [Revised: 12/24/2018] [Accepted: 12/26/2018] [Indexed: 01/16/2023] Open
Abstract
Background
Coronary computed tomography angiography (CCTA) is now widely used in the diagnosis of coronary artery disease since it is a rapid, minimally invasive test with a diagnostic accuracy comparable to coronary angiography. However, to meet demands for increasing spatial and temporal resolution, higher x-ray radiation doses are required to circumvent the resulting increase in image noise. Exposure to high doses of ionizing radiation with CT imaging is a major health concern due to the potential risk of radiation-associated malignancy. Given its increasing use, a number of dose saving algorithms have been implemented to CCTA to minimize radiation exposure to “as low as reasonably achievable (ALARA)” without compromising diagnostic image quality. Objective
The purpose of this review is to outline the most recent advances and current status of dose saving techniques in CCTA. Method
PubMed, Medline, EMBASE and Scholar databases were searched to identify feasibility studies, clinical trials, and technology guidelines on the technical advances in CT scanner hardware and reconstruction software. Results
Sub-millisievert (mSv) radiation doses have been reported for CCTA due to a combination of strategies such as prospective electrocardiogram-gating, high-pitch helical acquisition, tube current modulation, tube voltage reduction, heart rate reduction, and the most recent novel adaptive iterative reconstruction algorithms. Conclusion
Advances in radiation dose reduction without loss of image quality justify the use of CCTA as a non-invasive alternative to coronary catheterization in the diagnosis of coronary artery disease.
Collapse
Affiliation(s)
- Caryl E Richards
- Department of Cardiology, Morriston Hospital, Heol Maes Eglwys, Morriston, Swansea, SA6 6NL, United Kingdom
| | - Daniel R Obaid
- Department of Cardiology, Morriston Hospital, Heol Maes Eglwys, Morriston, Swansea, SA6 6NL, United Kingdom.,Swansea University Medical School, Swansea University, Grove Building, Singleton Park, Sketty, Swansea SA2 8PP, United Kingdom
| |
Collapse
|
10
|
Xu Y, Yamashiro T, Moriya H, Muramatsu S, Murayama S. Quantitative Emphysema Measurement On Ultra-High-Resolution CT Scans. Int J Chron Obstruct Pulmon Dis 2019; 14:2283-2290. [PMID: 31631998 PMCID: PMC6790117 DOI: 10.2147/copd.s223605] [Citation(s) in RCA: 12] [Impact Index Per Article: 2.4] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/17/2019] [Accepted: 09/23/2019] [Indexed: 12/29/2022] Open
Abstract
Purpose To evaluate the advantages of ultra-high-resolution computed tomography (U-HRCT) scans for the quantitative measurement of emphysematous lesions over conventional HRCT scans. Materials and methods This study included 32 smokers under routine clinical care who underwent chest CT performed by a U-HRCT scanner. Chronic obstructive pulmonary disease (COPD) was diagnosed in 13 of the 32 participants. Scan data were reconstructed by 2 different protocols: i) U-HRCT mode with a 1024×1024 matrix and 0.25-mm slice thickness and ii) conventional HRCT mode with a 512×512 matrix and 0.5-mm slice thickness. On both types of scans, lesions of emphysema were quantitatively assessed as percentage of low attenuation volume (LAV%, <-950 Hounsfield units). LAV% values determined for scan data from the U-HRCT and conventional HRCT modes were compared by the Wilcoxon matched-pairs signed rank test. The association between LAV% and forced expiratory volume in 1 s per forced vital capacity (FEV1/FVC) was assessed by the Spearman rank correlation test. Results Mean values for LAV% determined for the U-HRCT and conventional HRCT modes were 8.9 ± 8.8% and 7.3 ± 8.4%, respectively (P<0.0001). The correlation coefficients for LAV% and FEV1/FVC on the U-HRCT and conventional HRCT modes were 0.50 and 0.49, respectively (both P<0.01). Conclusion Compared with conventional HRCT scans, U-HRCT scans reveal emphysematous lesions in greater detail, and provide slightly increased correlation with airflow limitation.
Collapse
Affiliation(s)
- Yanyan Xu
- Department of Radiology, Graduate School of Medical Science, University of the Ryukyus, Okinawa, Japan.,Department of Radiology, China-Japan Friendship Hospital, Beijing, People's Republic of China
| | - Tsuneo Yamashiro
- Department of Radiology, Graduate School of Medical Science, University of the Ryukyus, Okinawa, Japan.,Department of Radiology, Ohara General Hospital, Fukushima, Japan
| | - Hiroshi Moriya
- Department of Radiology, Ohara General Hospital, Fukushima, Japan
| | - Shun Muramatsu
- Department of Radiology, Ohara General Hospital, Fukushima, Japan
| | - Sadayuki Murayama
- Department of Radiology, Graduate School of Medical Science, University of the Ryukyus, Okinawa, Japan
| |
Collapse
|
11
|
O'Brien C, Kok HK, Kelly B, Kumamaru K, Sahadevan A, Lane S, Buckley O. To investigate dose reduction and comparability of standard dose CT vs Ultra low dose CT in evaluating pulmonary emphysema. Clin Imaging 2019; 53:115-119. [DOI: 10.1016/j.clinimag.2018.10.012] [Citation(s) in RCA: 6] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/05/2018] [Revised: 10/11/2018] [Accepted: 10/12/2018] [Indexed: 12/01/2022]
|
12
|
Ohno Y, Koyama H, Seki S, Kishida Y, Yoshikawa T. Radiation dose reduction techniques for chest CT: Principles and clinical results. Eur J Radiol 2018; 111:93-103. [PMID: 30691672 DOI: 10.1016/j.ejrad.2018.12.017] [Citation(s) in RCA: 24] [Impact Index Per Article: 4.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/31/2018] [Revised: 12/06/2018] [Accepted: 12/16/2018] [Indexed: 11/19/2022]
Abstract
Computer tomography plays a major role in the evaluation of thoracic diseases, especially since the advent of the multidetector-row CT (MDCT) technology. However, the increase use of this technique has raised some concerns about the resulting radiation dose. In this review, we will present the various methods allowing limiting the radiation dose exposure resulting from chest CT acquisitions, including the options of image filtering and iterative reconstruction (IR) algorithms. The clinical applications of reduced dose protocols will be reviewed, especially for lung nodule detection and diagnosis of pulmonary thromboembolism. The performance of reduced dose protocols for infiltrative lung disease assessment will also be discussed. Lastly, the influence of using IR algorithms on computer-aided detection and volumetry of lung nodules, as well as on quantitative and functional assessment of chest diseases will be presented and discussed.
Collapse
Affiliation(s)
- Yoshiharu Ohno
- Division of Functional and Diagnostic Imaging Research, Department of Radiology, Kobe University Graduate School of Medicine, Japan; Advanced Biomedical Imaging Research Center, Kobe University Graduate School of Medicine, Japan.
| | | | - Shinichiro Seki
- Division of Functional and Diagnostic Imaging Research, Department of Radiology, Kobe University Graduate School of Medicine, Japan; Advanced Biomedical Imaging Research Center, Kobe University Graduate School of Medicine, Japan
| | - Yuji Kishida
- Division of Radiology, Department of Radiology, Kobe University Graduate School of Medicine, Japan
| | - Takeshi Yoshikawa
- Division of Functional and Diagnostic Imaging Research, Department of Radiology, Kobe University Graduate School of Medicine, Japan; Advanced Biomedical Imaging Research Center, Kobe University Graduate School of Medicine, Japan
| |
Collapse
|
13
|
Ludes C, Labani A, Severac F, Jeung MY, Leyendecker P, Roy C, Ohana M. Ultra-low-dose unenhanced chest CT: Prospective comparison of high kV/low mA versus low kV/high mA protocols. Diagn Interv Imaging 2018; 100:85-93. [PMID: 30559037 DOI: 10.1016/j.diii.2018.11.012] [Citation(s) in RCA: 16] [Impact Index Per Article: 2.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/06/2018] [Revised: 11/14/2018] [Accepted: 11/19/2018] [Indexed: 12/11/2022]
Abstract
PURPOSE To qualitatively and quantitatively compare unenhanced ultra-low-dose chest computed tomography (ULD-CT) acquired at 80kVp and 135kVp. MATERIALS AND METHODS Fifty-one patients referred for unenhanced chest CT were prospectively included. There were 29 men and 22 women, with a mean age of 64.7±11.6 (SD) years (range: 35-91 years) and a mean body mass index of 26.2±6.3 (SD) (range: 17-54.9). All patients underwent two different ULD-CT protocols (80kVp-40mA and 135kVp-10mA). Image quality of both ULD-CT examinations using a 5-level scale as well as assessability of 6 predetermined lung parenchyma lesions were blindly evaluated by three radiologists and compared using a logistic regression model. Image noise of the two protocols was compared with Wilcoxon signed-rank test. RESULTS The mean dose-length product at 80kVp and at 135kVp were 14.7±1.8 (SD) mGy.cm and 15.6±1.9 (SD) mGy.cm, respectively (P<0.001). Image noise was significantly lower at 135kVp (58.9±12.4) than at 80kVp (74.7±14.5) (P<0.001). For all readers and for all examinations, the 135kVp protocol yielded better image quality than 80kVp protocol, with a mean qualitative score of 4.5±0.7 versus 3.9±0.8 (P<0.001). The 135kVp protocol was significantly more often of diagnostic quality than the 80kvp protocol (92.3% versus 77.8%, respectively) (P<0.001) and was less prone to image quality deterioration in obese patients. Parenchymal lesions were never better depicted on the 80kVp protocol than with the 135kVp protocol. CONCLUSION Unenhanced chest ULD-CT should be acquired at a high kilovoltage and low current, such as 135kVp-10mA, over a low kilovoltage and high current protocol.
Collapse
Affiliation(s)
- C Ludes
- Department of Radiology B, Nouvel Hôpital Civil, Hôpitaux Universitaires de Strasbourg, 67000 Strasbourg, France
| | - A Labani
- Department of Radiology B, Nouvel Hôpital Civil, Hôpitaux Universitaires de Strasbourg, 67000 Strasbourg, France
| | - F Severac
- Department of Public Health, Hôpital Civil, Hôpitaux Universitaires de Strasbourg, 67000 Strasbourg, France; iCube Laboratory, Université de Strasbourg, CNRS, UMR 7357, 67400 Illkirch, France
| | - M Y Jeung
- Department of Radiology B, Nouvel Hôpital Civil, Hôpitaux Universitaires de Strasbourg, 67000 Strasbourg, France
| | - P Leyendecker
- Department of Radiology B, Nouvel Hôpital Civil, Hôpitaux Universitaires de Strasbourg, 67000 Strasbourg, France
| | - C Roy
- Department of Radiology B, Nouvel Hôpital Civil, Hôpitaux Universitaires de Strasbourg, 67000 Strasbourg, France
| | - M Ohana
- Department of Radiology B, Nouvel Hôpital Civil, Hôpitaux Universitaires de Strasbourg, 67000 Strasbourg, France; iCube Laboratory, Université de Strasbourg, CNRS, UMR 7357, 67400 Illkirch, France.
| |
Collapse
|
14
|
Nagatani Y, Takahashi M, Ikeda M, Nitta N, Miyata K, Hanaoka J, Nakano Y, Matsuo S, Hamada Y, Sonoda A, Otani H, Ushio N, Ohta S, Murakami Y, Kaneko C, Inoue A, Kida T, Murata K. Sub-solid nodule detectability in seven observers of seventy-nine clinical cases: comparison between ultra-low-dose chest digital tomosynthesis with iterative reconstruction and chest radiography by receiver-operating characteristics analysis. Eur J Radiol 2018; 107:166-174. [DOI: 10.1016/j.ejrad.2018.08.006] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/23/2018] [Revised: 07/30/2018] [Accepted: 08/09/2018] [Indexed: 12/16/2022]
|
15
|
Hoyoshi K, Satou T, Okada A. [Effect of Hybrid Iterative Reconstruction on CT Image Quality Using Metal Artifact Reduction]. Nihon Hoshasen Gijutsu Gakkai Zasshi 2018; 74:797-804. [PMID: 30122744 DOI: 10.6009/jjrt.2018_jsrt_74.8.797] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/11/2022]
Abstract
PURPOSE This study aimed to evaluate the effect of adaptive iterative dose reduction 3D (AIDR 3D) on the computed tomography (CT) image quality by using single energy metal artifact reduction (SEMAR). MATERIALS & METHODS A water phantom (22 cmφ) with the stem for total hip arthroplasty made of titanium was scanned. The volume CT dose index (CTDIvol) was set to 8.9 and 5.0 mGy. The reconstruction was performed using filtered back projection and AIDR 3D by soft kernel (FC13) and SEMAR. The averaged profile method was used for the quantitative evaluation of artifacts. We placed a rectangular region-of-interest on the artifact part, and obtained the x-direction averaged profile (Profile A). Profile B was obtained using a water phantom without metal. Profiles A and B were normalized as Profiles A' and B' using the mean value calculated from Profile B. Based on the standard deviation (SD) calculated from Profile B', the background variation level was defined as ±2SD, and subtracted from Profile A' (Profile A″). Finally, the area of Profile A″ was calculated and defined as Artifacttotal. Artifactover, and Artifactunder, respectively, the positive- and negative-side components of Artifacttotal. RESULTS Both Artifacttotal and Artifactunder increased according to the strength of AIDR 3D. The variations of Artifactover and Artifactunder, due to the AIDR 3D strength, were small and large, respectively. Further, in comparison with a high dose, the effect of artifact emphasis increased at low dose. Therefore, it should be noted that stronger AIDR 3D can emphasize the residual metal artifact.
Collapse
Affiliation(s)
| | | | - Akio Okada
- Department of Radiology, Yamagata University Hospital
| |
Collapse
|
16
|
Lee KH, Lee KW, Park JH, Han K, Kim J, Lee SM, Park CM. Nodule Classification on Low-Dose Unenhanced CT and Standard-Dose Enhanced CT: Inter-Protocol Agreement and Analysis of Interchangeability. Korean J Radiol 2018; 19:516-525. [PMID: 29713230 PMCID: PMC5904479 DOI: 10.3348/kjr.2018.19.3.516] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/23/2017] [Accepted: 11/13/2017] [Indexed: 12/19/2022] Open
Abstract
Objective To measure inter-protocol agreement and analyze interchangeability on nodule classification between low-dose unenhanced CT and standard-dose enhanced CT. Materials and Methods From nodule libraries containing both low-dose unenhanced and standard-dose enhanced CT, 80 solid and 80 subsolid (40 part-solid, 40 non-solid) nodules of 135 patients were selected. Five thoracic radiologists categorized each nodule into solid, part-solid or non-solid. Inter-protocol agreement between low-dose unenhanced and standard-dose enhanced images was measured by pooling κ values for classification into two (solid, subsolid) and three (solid, part-solid, non-solid) categories. Interchangeability between low-dose unenhanced and standard-dose enhanced CT for the classification into two categories was assessed using a pre-defined equivalence limit of 8 percent. Results Inter-protocol agreement for the classification into two categories {κ, 0.96 (95% confidence interval [CI], 0.94-0.98)} and that into three categories (κ, 0.88 [95% CI, 0.85-0.92]) was considerably high. The probability of agreement between readers with standard-dose enhanced CT was 95.6% (95% CI, 94.5-96.6%), and that between low-dose unenhanced and standard-dose enhanced CT was 95.4% (95% CI, 94.7-96.0%). The difference between the two proportions was 0.25% (95% CI, -0.85-1.5%), wherein the upper bound CI was markedly below 8 percent. Conclusion Inter-protocol agreement for nodule classification was considerably high. Low-dose unenhanced CT can be used interchangeably with standard-dose enhanced CT for nodule classification.
Collapse
Affiliation(s)
- Kyung Hee Lee
- Department of Radiology, Seoul National University Bundang Hospital, Seongnam 13620, Korea
| | - Kyung Won Lee
- Department of Radiology, Seoul National University Bundang Hospital, Seongnam 13620, Korea
| | - Ji Hoon Park
- Department of Radiology, Seoul National University Bundang Hospital, Seongnam 13620, Korea
| | - Kyunghwa Han
- Department of Radiology, Research Institute of Radiological Science, Yonsei University College of Medicine, Seoul 03722, Korea
| | - Jihang Kim
- Department of Radiology, Seoul National University Bundang Hospital, Seongnam 13620, Korea
| | - Sang Min Lee
- Department of Radiology and Research Institute of Radiology, University of Ulsan College of Medicine, Asan Medical Center, Seoul 05505, Korea
| | - Chang Min Park
- Department of Radiology, Seoul National University Hospital, Seoul National University College of Medicine, Seoul 03080, Korea.,Cancer Research Institute, Seoul National University College of Medicine, Seoul 03080, Korea
| |
Collapse
|
17
|
Nagatani Y, Takahashi M, Ikeda M, Yamashiro T, Koyama H, Koyama M, Moriya H, Noma S, Tomiyama N, Ohno Y, Murata K, Murayama S, Moriya H, Sakuma K, Koyama M, Honda O, Tomiyama N, Koyama H, Ohno Y, Sugimura K, Sakamoto R, Nishimoto Y, Noma S, Tada A, Kato K, Miyara T, Yamashiro T, Kamiya H, Kamiya A, Tanaka Y, Murayama S, Nagatani Y, Nitta N, Takahashi M, Murata K. Sub-solid Nodule Detection Performance on Reduced-dose Computed Tomography with Iterative Reduction: Comparison Between 20 mA (7 mAs) and 120 mA (42 mAs) Regarding Nodular Size and Characteristics and Association with Size-specific Dose Estimate. Acad Radiol 2017; 24:995-1007. [PMID: 28606593 DOI: 10.1016/j.acra.2017.01.004] [Citation(s) in RCA: 7] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/03/2016] [Revised: 01/11/2017] [Accepted: 01/13/2017] [Indexed: 12/17/2022]
Abstract
RATIONALE AND OBJECTIVES This study aimed to compare sub-solid nodule detection performances (SSNDP) on chest computed tomography (CT) with Adaptive Iterative Dose Reduction using Three Dimensional Processing (AIDR 3D) between 7 mAs (0.21 mSv) and 42 mAs (1.28 mSv) in total and in subgroups classified by nodular size, characteristics, and location, and analyze the association of SSNDP with size-specific dose estimate (SSDE). MATERIALS AND METHODS As part of the Area-detector Computed Tomography for the Investigation of Thoracic Diseases Study, a Japanese multicenter research project, 68 subjects underwent chest CT with 120 kV, 0.35 seconds per rotation, and three tube currents: 240 mA (84 mAs), 120 mA (42 mAs), and 20 mA (7 mAs). The research committee of the study project outlined and approved our study protocols. The institutional review board of each institution approved this study. Axial 2-mm-thick CT images were reconstructed using AIDR 3D. Standard reference was determined by CT images at 84 mAs. Four radiologists recorded SSN presence by continuously distributed rating on CT at 7 mAs and 42 mAs. Receiver operating characteristic analysis was used to evaluate SSNDP at both doses in total and in subgroups classified by nodular longest diameter (LD) (≥5 mm), characteristics (pure and part-solid), and locations (ventral, intermediate, or dorsal; central or peripheral; and upper, middle, or lower). Detection sensitivity was compared among five groups of SSNs classified based on particular SSDE to nodule on CT with AIDR 3D at 7 mAs. RESULTS Twenty-two part-solid and 86 pure SSNs were identified. For larger SSNs (LD ≥ 5 mm) as well as subgroups classified by nodular locations and part-solid nodules, SSNDP was similar in both methods (area under the receiver operating characteristics curve: 0.96 ± 0.02 in CT at 7 mAs and 0.97 ± 0.01 in CT at 42 mAs), with acceptable interobserver agreements in five locations. For larger SSNs (LD ≥ 5 mm), on CT at 42 mAs, no significant differences in detection sensitivity were found among the five groups classified by SSDE, whereas on CT with 7 mAs, four groups with SSDE of 0.65 or higher were superior in detection sensitivity to the other group, with SSDE less than 0.65 mGy. CONCLUSIONS For SSNs with 5 mm or more in cases with normal range of body habitus, CT at 7 mAs was demonstrated to have comparable SSNDP to CT at 42 mAs regardless of nodular location and characteristics, and SSDE higher than 0.65 mGy is desirable to obtain sufficient SSNDP.
Collapse
|
18
|
Martini K, Barth BK, Higashigaito K, Baumueller S, Alkadhi H, Frauenfelder T. Dose-Optimized Computed Tomography for Screening and Follow-Up of Solid Pulmonary Nodules in Obesity: A Phantom Study. Curr Probl Diagn Radiol 2017; 46:204-209. [DOI: 10.1067/j.cpradiol.2016.07.005] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/14/2015] [Revised: 06/13/2016] [Accepted: 07/28/2016] [Indexed: 12/21/2022]
|
19
|
Breast dose reduction for chest CT by modifying the scanning parameters based on the pre-scan size-specific dose estimate (SSDE). Eur Radiol 2016; 27:2267-2274. [DOI: 10.1007/s00330-016-4618-6] [Citation(s) in RCA: 7] [Impact Index Per Article: 0.9] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/25/2016] [Revised: 09/12/2016] [Accepted: 09/22/2016] [Indexed: 01/20/2023]
|
20
|
Takegami K, Hayashi H, Yamada K, Mihara Y, Kimoto N, Kanazawa Y, Higashino K, Yamashita K, Hayashi F, Okazaki T, Hashizume T, Kobayashi I. Entrance surface dose measurements using a small OSL dosimeter with a computed tomography scanner having 320 rows of detectors. Radiol Phys Technol 2016; 10:49-59. [DOI: 10.1007/s12194-016-0366-1] [Citation(s) in RCA: 11] [Impact Index Per Article: 1.4] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/21/2016] [Revised: 06/13/2016] [Accepted: 06/14/2016] [Indexed: 11/25/2022]
|
21
|
Yamashiro T, Moriya H, Tsubakimoto M, Matsuoka S, Murayama S. Continuous quantitative measurement of the proximal airway dimensions and lung density on four-dimensional dynamic-ventilation CT in smokers. Int J Chron Obstruct Pulmon Dis 2016; 11:755-64. [PMID: 27110108 PMCID: PMC4835141 DOI: 10.2147/copd.s100658] [Citation(s) in RCA: 25] [Impact Index Per Article: 3.1] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/18/2022] Open
Abstract
Purpose Four-dimensional dynamic-ventilation computed tomography (CT) imaging demonstrates continuous movement of the airways and lungs, which cannot be depicted with conventional CT. We aimed to investigate continuous changes in lung density and airway dimensions and to assess the correlation with spirometric values in smokers. Materials and methods This retrospective study was approved by the Institutional Review Board, and informed consent was waived. Twenty-one smokers including six patients with COPD underwent four-dimensional dynamic-ventilation CT during free breathing (160 mm in length). The mean lung density (MLD) of the scanned lung and luminal areas (Ai) of fixed points in the trachea and the right proximal bronchi (main bronchus, upper bronchus, bronchus intermedius, and lower bronchus) were continuously measured. Concordance between the time curve of the MLD and that of the airway Ai values was expressed by cross-correlation coefficients. The associations between these quantitative measurements and the forced expiratory volume in 1 second/forced vital capacity (FEV1/FVC) values were assessed by Spearman’s rank correlation analysis. Results On the time curve for the MLD, the Δ-MLD1.05 values between the peak inspiratory frame to the later third frame (1.05 seconds later) were strongly correlated with the FEV1/FVC (ρ=0.76, P<0.0001). The cross-correlation coefficients between the airway Ai and MLD values were significantly correlated with the FEV1/FVC (ρ=−0.56 to −0.66, P<0.01), except for the right upper bronchus. This suggested that the synchrony between the airway and lung movement was lost in patients with severe airflow limitation. Conclusion Respiratory changes in the MLD and synchrony between the airway Ai and the MLD measured with dynamic-ventilation CT were correlated with patient’s spirometric values.
Collapse
Affiliation(s)
- Tsuneo Yamashiro
- Department of Radiology, Graduate School of Medical Science, University of the Ryukyus, Nishihara, Okinawa, Japan
| | - Hiroshi Moriya
- Department of Radiology, Ohara General Hospital, Fukushima-shi, Fukushima, Japan
| | - Maho Tsubakimoto
- Department of Radiology, Graduate School of Medical Science, University of the Ryukyus, Nishihara, Okinawa, Japan
| | - Shin Matsuoka
- Department of Radiology, St Marianna University School of Medicine, Kawasaki, Kanagawa, Japan
| | - Sadayuki Murayama
- Department of Radiology, Graduate School of Medical Science, University of the Ryukyus, Nishihara, Okinawa, Japan
| |
Collapse
|
22
|
Abstract
More than other medical discipline, radiology is marked by technical innovation and continuous development, as well as the optimization of the underlying physical principles. In this respect, several trends that will crucially change and develop radiology over the next decade can be observed. Through the use of ever faster computer tomography, which also shows an ever-decreasing radiation exposure, the "workhorse" of radiology will have an even greater place and displace conventional X‑ray techniques further. In addition, hybrid imaging, which is based on a combination of nuclear medicine and radiological techniques (keywords: PET/CT, PET/MRI) will become much more established and, in particular, will improve oncological imaging further, allowing increasingly individualized imaging for specific tracers and techniques of functional magnetic resonance imaging for a particular tumour. Future radiology will be strongly characterized by innovations in the software and Internet industry, which will enable new image viewing and processing methods and open up new possibilities in the context of the organization of radiological work.
Collapse
|
23
|
Radiation Dose Reduction in Pediatric Body CT Using Iterative Reconstruction and a Novel Image-Based Denoising Method. AJR Am J Roentgenol 2016; 205:1026-37. [PMID: 26496550 DOI: 10.2214/ajr.14.14185] [Citation(s) in RCA: 16] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/18/2022]
Abstract
OBJECTIVE The objective of this study was to evaluate the radiation dose reduction potential of a novel image-based denoising technique in pediatric abdominopelvic and chest CT examinations and compare it with a commercial iterative reconstruction method. MATERIALS AND METHODS Data were retrospectively collected from 50 (25 abdominopelvic and 25 chest) clinically indicated pediatric CT examinations. For each examination, a validated noise-insertion tool was used to simulate half-dose data, which were reconstructed using filtered back-projection (FBP) and sinogram-affirmed iterative reconstruction (SAFIRE) methods. A newly developed denoising technique, adaptive nonlocal means (aNLM), was also applied. For each of the 50 patients, three pediatric radiologists evaluated four datasets: full dose plus FBP, half dose plus FBP, half dose plus SAFIRE, and half dose plus aNLM. For each examination, the order of preference for the four datasets was ranked. The organ-specific diagnosis and diagnostic confidence for five primary organs were recorded. RESULTS The mean (± SD) volume CT dose index for the full-dose scan was 5.3 ± 2.1 mGy for abdominopelvic examinations and 2.4 ± 1.1 mGy for chest examinations. For abdominopelvic examinations, there was no statistically significant difference between the half dose plus aNLM dataset and the full dose plus FBP dataset (3.6 ± 1.0 vs 3.6 ± 0.9, respectively; p = 0.52), and aNLM performed better than SAFIRE. For chest examinations, there was no statistically significant difference between the half dose plus SAFIRE and the full dose plus FBP (4.1 ± 0.6 vs 4.2 ± 0.6, respectively; p = 0.67), and SAFIRE performed better than aNLM. For all organs, there was more than 85% agreement in organ-specific diagnosis among the three half-dose configurations and the full dose plus FBP configuration. CONCLUSION Although a novel image-based denoising technique performed better than a commercial iterative reconstruction method in pediatric abdominopelvic CT examinations, it performed worse in pediatric chest CT examinations. A 50% dose reduction can be achieved while maintaining diagnostic quality.
Collapse
|
24
|
Influence of Sinogram-Affirmed Iterative Reconstruction on Computed Tomography–Based Lung Volumetry and Quantification of Pulmonary Emphysema. J Comput Assist Tomogr 2016; 40:96-101. [DOI: 10.1097/rct.0000000000000313] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/26/2022]
|
25
|
Evaluation of pulmonary nodules and infection on chest CT with radiation dose equivalent to chest radiography: Prospective intra-individual comparison study to standard dose CT. Eur J Radiol 2015; 85:360-5. [PMID: 26781141 DOI: 10.1016/j.ejrad.2015.11.036] [Citation(s) in RCA: 41] [Impact Index Per Article: 4.6] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/13/2015] [Revised: 11/26/2015] [Accepted: 11/27/2015] [Indexed: 12/20/2022]
Abstract
PURPOSE To compare prospectively, in patients undergoing chest computed tomography (CT) for pulmonary-nodules or infection, image-quality and accuracy of standard dose (SD) and reduced dose (RD) CT with tin-filtration. MATERIAL AND METHODS This IRB-approved study included 100 consecutive patients (36 female;median age 56 years) referred for follow-up of pulmonary-nodules (n=43) or suspicion of infection (n=57) undergoing single-energy CT with SD and RD using tin-filtration at 100 kVp (CTDIvol 2.47 mGy and 0.07 mGy, respectively). Images were reconstructed with advanced modeled iterative reconstruction (ADMIRE) at strength 3 and 5. Image-noise was measured. Two independent readers evaluated nodules and pulmonary-infection. SD CT served as reference standard. RESULTS No significant difference was found in noise between RD with ADMIRE5 and SD with ADMIRE3 (118HU ± 14 vs. 120HU ± 17; p=0.08). Sensitivity for detection of atelectasis and interstitial lung changes was higher in images reconstructed with ADMIRE5 (93% and 88%; respectively) than in those reconstructed with ADIMRE3 (77% and 78%; respectively). Sensitivity for detection of consolidations was 90% for ADMIRE3 and 89% for ADMIRE5. Sensitivity for nodule detection was 71% for ADMIRE3 and 81% for ADMIRE5. Specificity for detection of atelectasis and interstitial lung changes was 99% and 96% with ADMIRE5 and 99% and 96% with ADMIRE3. Specificity for detection of consolidations was 99% for ADMIRE3 and 5. Specificity for detection of nodules was 87% for both ADMIRE3 and 5. CONCLUSION Chest CT with a radiation dose equivalent to conventional radiography is feasible and allows for detection of pulmonary infection with high sensitivity, whereas the accuracy for detecting nodules is only moderate.
Collapse
|
26
|
Image Quality and Radiation Dose of CT Coronary Angiography with Automatic Tube Current Modulation and Strong Adaptive Iterative Dose Reduction Three-Dimensional (AIDR3D). PLoS One 2015; 10:e0142185. [PMID: 26599111 PMCID: PMC4657884 DOI: 10.1371/journal.pone.0142185] [Citation(s) in RCA: 7] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/07/2014] [Accepted: 10/19/2015] [Indexed: 02/07/2023] Open
Abstract
Purpose To investigate image quality and radiation dose of CT coronary angiography (CTCA) scanned using automatic tube current modulation (ATCM) and reconstructed by strong adaptive iterative dose reduction three-dimensional (AIDR3D). Methods Eighty-four consecutive CTCA patients were collected for the study. All patients were scanned using ATCM and reconstructed with strong AIDR3D, standard AIDR3D and filtered back-projection (FBP) respectively. Two radiologists who were blinded to the patients' clinical data and reconstruction methods evaluated image quality. Quantitative image quality evaluation included image noise, signal-to-noise ratio (SNR), and contrast-to-noise ratio (CNR). To evaluate image quality qualitatively, coronary artery is classified into 15 segments based on the modified guidelines of the American Heart Association. Qualitative image quality was evaluated using a 4-point scale. Radiation dose was calculated based on dose-length product. Results Compared with standard AIDR3D, strong AIDR3D had lower image noise, higher SNR and CNR, their differences were all statistically significant (P<0.05); compared with FBP, strong AIDR3D decreased image noise by 46.1%, increased SNR by 84.7%, and improved CNR by 82.2%, their differences were all statistically significant (P<0.05 or 0.001). Segments with diagnostic image quality for strong AIDR3D were 336 (100.0%), 486 (96.4%), and 394 (93.8%) in proximal, middle, and distal part respectively; whereas those for standard AIDR3D were 332 (98.8%), 472 (93.7%), 378 (90.0%), respectively; those for FBP were 217 (64.6%), 173 (34.3%), 114 (27.1%), respectively; total segments with diagnostic image quality in strong AIDR3D (1216, 96.5%) were higher than those of standard AIDR3D (1182, 93.8%) and FBP (504, 40.0%); the differences between strong AIDR3D and standard AIDR3D, strong AIDR3D and FBP were all statistically significant (P<0.05 or 0.001). The mean effective radiation dose was (2.55±1.21) mSv. Conclusion Compared with standard AIDR3D and FBP, CTCA with ATCM and strong AIDR3D could significantly improve both quantitative and qualitative image quality.
Collapse
|
27
|
Martini K, Higashigaito K, Barth BK, Baumueller S, Alkadhi H, Frauenfelder T. Ultralow-dose CT with tin filtration for detection of solid and sub solid pulmonary nodules: a phantom study. Br J Radiol 2015; 88:20150389. [PMID: 26492317 DOI: 10.1259/bjr.20150389] [Citation(s) in RCA: 29] [Impact Index Per Article: 3.2] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/21/2022] Open
Abstract
OBJECTIVES To investigate the diagnostic performance of advanced modelled iterative reconstruction (ADMIRE) to filtered back projection (FBP) when using an ultralow-dose protocol for the detection of solid and subsolid pulmonary nodules. METHODS Single-energy CT was performed at 100 kVp with tin filtration in an anthropomorphic chest phantom with solid and subsolid pulmonary nodules (2-10 mm, attenuation, 20 to -800 HU at 120 kVp). The mean volume CT dose index (CTDIvol) of the standard chest protocol was 2.2 mGy. Subsequent scans were obtained at 1/8 (0.28 mGy), 1/20 (0.10 mGy) and 1/70 (0.03 mGy) dose levels by lowering tube voltage and tube current. Images were reconstructed with FBP and ADMIRE. One reader measured image noise; two readers determined image quality and assessed nodule localization. RESULTS Image noise was significantly reduced using ADMIRE compared with FBP (ADMIRE at a strength level of 5 : 70.4% for 1/20; 71.6% for 1/8; p < 0.001). Interobserver agreement for image quality was excellent (k = 0.88). Image quality was considered diagnostic for all images at 1/20 dose using ADMIRE. Sensitivity of nodule detection was 97.1% (100% for solid, 93.8% for subsolid nodules) at 1/20 dose and 100% for both nodule entities at 1/8 dose using ADMIRE 5. Images obtained with 1/70 dose had moderate sensitivity (overall 85.7%; solid 95%; subsolid 73.3%). CONCLUSION Our study suggests that with a combination of tin filtration and ADMIRE, the CTDIvol of chest CT can be lowered considerably, while sensitivity for nodule detection remains high. For solid nodules, CTDIvol was 0.10 mGy, while subsolid nodules required a slightly higher CTDIvol of 0.28 mGy. ADVANCES IN KNOWLEDGE Detection of subsolid nodules is feasible with ultralow-dose protocols.
Collapse
Affiliation(s)
- Katharina Martini
- University Hospital Zurich, Department of Diagnostic and Interventional Radiology/University of Zurich, Zurich, Switzerland
| | - Kai Higashigaito
- University Hospital Zurich, Department of Diagnostic and Interventional Radiology/University of Zurich, Zurich, Switzerland
| | - Borna K Barth
- University Hospital Zurich, Department of Diagnostic and Interventional Radiology/University of Zurich, Zurich, Switzerland
| | - Stephan Baumueller
- University Hospital Zurich, Department of Diagnostic and Interventional Radiology/University of Zurich, Zurich, Switzerland
| | - Hatem Alkadhi
- University Hospital Zurich, Department of Diagnostic and Interventional Radiology/University of Zurich, Zurich, Switzerland
| | - Thomas Frauenfelder
- University Hospital Zurich, Department of Diagnostic and Interventional Radiology/University of Zurich, Zurich, Switzerland
| |
Collapse
|
28
|
Yamashiro T, Tsubakimoto M, Nagatani Y, Moriya H, Sakuma K, Tsukagoshi S, Inokawa H, Kimoto T, Teramoto R, Murayama S. Automated continuous quantitative measurement of proximal airways on dynamic ventilation CT: initial experience using an ex vivo porcine lung phantom. Int J Chron Obstruct Pulmon Dis 2015; 10:2045-54. [PMID: 26445535 PMCID: PMC4590570 DOI: 10.2147/copd.s87588] [Citation(s) in RCA: 8] [Impact Index Per Article: 0.9] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/30/2022] Open
Abstract
Background The purpose of this study was to evaluate the feasibility of continuous quantitative measurement of the proximal airways, using dynamic ventilation computed tomography (CT) and our research software. Methods A porcine lung that was removed during meat processing was ventilated inside a chest phantom by a negative pressure cylinder (eight times per minute). This chest phantom with imitated respiratory movement was scanned by a 320-row area-detector CT scanner for approximately 9 seconds as dynamic ventilatory scanning. Obtained volume data were reconstructed every 0.35 seconds (total 8.4 seconds with 24 frames) as three-dimensional images and stored in our research software. The software automatically traced a designated airway point in all frames and measured the cross-sectional luminal area and wall area percent (WA%). The cross-sectional luminal area and WA% of the trachea and right main bronchus (RMB) were measured for this study. Two radiologists evaluated the traceability of all measurable airway points of the trachea and RMB using a three-point scale. Results It was judged that the software satisfactorily traced airway points throughout the dynamic ventilation CT (mean score, 2.64 at the trachea and 2.84 at the RMB). From the maximum inspiratory frame to the maximum expiratory frame, the cross-sectional luminal area of the trachea decreased 17.7% and that of the RMB 29.0%, whereas the WA% of the trachea increased 6.6% and that of the RMB 11.1%. Conclusion It is feasible to measure airway dimensions automatically at designated points on dynamic ventilation CT using research software. This technique can be applied to various airway and obstructive diseases.
Collapse
Affiliation(s)
- Tsuneo Yamashiro
- Department of Radiology, Graduate School of Medical Science, University of the Ryukyus, Nishihara, Okinawa, Japan
| | - Maho Tsubakimoto
- Department of Radiology, Graduate School of Medical Science, University of the Ryukyus, Nishihara, Okinawa, Japan
| | - Yukihiro Nagatani
- Department of Radiology, Shiga University of Medical Science, Otsu, Japan
| | - Hiroshi Moriya
- Department of Radiology, Ohara General Hospital, Fukushima, Japan
| | - Kotaro Sakuma
- Department of Radiology, Ohara General Hospital, Fukushima, Japan
| | | | - Hiroyasu Inokawa
- Center for Medical Research and Development, Toshiba Medical Systems Corporation, Otawara, Japan
| | - Tatsuya Kimoto
- Center for Medical Research and Development, Toshiba Medical Systems Corporation, Otawara, Japan
| | - Ryuichi Teramoto
- Corporate Manufacturing Engineering Center, Toshiba Corporation, Yokohama, Japan
| | - Sadayuki Murayama
- Department of Radiology, Graduate School of Medical Science, University of the Ryukyus, Nishihara, Okinawa, Japan
| |
Collapse
|
29
|
|
30
|
Adaptively Tuned Iterative Low Dose CT Image Denoising. COMPUTATIONAL AND MATHEMATICAL METHODS IN MEDICINE 2015; 2015:638568. [PMID: 26089972 PMCID: PMC4458284 DOI: 10.1155/2015/638568] [Citation(s) in RCA: 17] [Impact Index Per Article: 1.9] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 01/23/2015] [Revised: 05/02/2015] [Accepted: 05/03/2015] [Indexed: 11/18/2022]
Abstract
Improving image quality is a critical objective in low dose computed tomography (CT) imaging and is the primary focus of CT image denoising. State-of-the-art CT denoising algorithms are mainly based on iterative minimization of an objective function, in which the performance is controlled by regularization parameters. To achieve the best results, these should be chosen carefully. However, the parameter selection is typically performed in an ad hoc manner, which can cause the algorithms to converge slowly or become trapped in a local minimum. To overcome these issues a noise confidence region evaluation (NCRE) method is used, which evaluates the denoising residuals iteratively and compares their statistics with those produced by additive noise. It then updates the parameters at the end of each iteration to achieve a better match to the noise statistics. By combining NCRE with the fundamentals of block matching and 3D filtering (BM3D) approach, a new iterative CT image denoising method is proposed. It is shown that this new denoising method improves the BM3D performance in terms of both the mean square error and a structural similarity index. Moreover, simulations and patient results show that this method preserves the clinically important details of low dose CT images together with a substantial noise reduction.
Collapse
|
31
|
Kidoh M, Hirai T, Oda S, Utsunomiya D, Kawano T, Yano S, Nakamura H, Makino K, Iryo Y, Azuma M, Hayashida E, Nakaura T, Yamashita Y. Can CT angiography reconstructed from CT perfusion source data on a 320-section volume CT scanner replace conventional CT angiography for the evaluation of intracranial arteries? Jpn J Radiol 2015; 33:353-9. [DOI: 10.1007/s11604-015-0429-y] [Citation(s) in RCA: 9] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/29/2015] [Accepted: 04/24/2015] [Indexed: 10/23/2022]
|
32
|
Lung nodule detection performance in five observers on computed tomography (CT) with adaptive iterative dose reduction using three-dimensional processing (AIDR 3D) in a Japanese multicenter study: Comparison between ultra-low-dose CT and low-dose CT by receiver-operating characteristic analysis. Eur J Radiol 2015; 84:1401-12. [PMID: 25892051 DOI: 10.1016/j.ejrad.2015.03.012] [Citation(s) in RCA: 49] [Impact Index Per Article: 5.4] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/17/2014] [Revised: 03/03/2015] [Accepted: 03/08/2015] [Indexed: 12/21/2022]
Abstract
PURPOSE To compare lung nodule detection performance (LNDP) in computed tomography (CT) with adaptive iterative dose reduction using three dimensional processing (AIDR3D) between ultra-low dose CT (ULDCT) and low dose CT (LDCT). MATERIALS AND METHODS This was part of the Area-detector Computed Tomography for the Investigation of Thoracic Diseases (ACTIve) Study, a multicenter research project being conducted in Japan. Institutional Review Board approved this study and informed consent was obtained. Eighty-three subjects (body mass index, 23.3 ± 3.2) underwent chest CT at 6 institutions using identical scanners and protocols. In a single visit, each subject was scanned using different tube currents: 240, 120 and 20 mA (3.52, 1.74 and 0.29 mSv, respectively). Axial CT images with 2-mm thickness/increment were reconstructed using AIDR3D. Standard of reference (SOR) was determined based on CT images at 240 mA by consensus reading of 2 board-certificated radiologists as to the presence of lung nodules with the longest diameter (LD) of more than 3mm. Another 5 radiologists independently assessed and recorded presence/absence of lung nodules and their locations by continuously-distributed rating in CT images at 20 mA (ULDCT) and 120 mA (LDCT). Receiver-operating characteristic (ROC) analysis was used to evaluate LNDP of both methods in total and also in subgroups classified by LD (>4, 6 and 8 mm) and nodular characteristics (solid and ground glass nodules). RESULTS For SOR, 161 solid and 60 ground glass nodules were identified. No significant difference in LNDP for entire solid nodules was demonstrated between both methods, as area under ROC curve (AUC) was 0.844 ± 0.017 in ULDCT and 0.876 ± 0.026 in LDCT (p=0.057). For ground glass nodules with LD 8mm or more, LNDP was similar between both methods, as AUC 0.899 ± 0.038 in ULDCT and 0.941 ± 0.030 in LDCT. (p=0.144). CONCLUSION ULDCT using AIDR3D with an equivalent radiation dose to chest x-ray could have comparable LNDP to LDCT with AIDR3D except for smaller ground glass nodules in cases with normal range body habitus.
Collapse
|
33
|
Yamashiro T, Miyara T, Honda O, Tomiyama N, Ohno Y, Noma S, Murayama S. Iterative reconstruction for quantitative computed tomography analysis of emphysema: consistent results using different tube currents. Int J Chron Obstruct Pulmon Dis 2015; 10:321-7. [PMID: 25709426 PMCID: PMC4334310 DOI: 10.2147/copd.s74810] [Citation(s) in RCA: 14] [Impact Index Per Article: 1.6] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/23/2022] Open
Abstract
Purpose To assess the advantages of iterative reconstruction for quantitative computed tomography (CT) analysis of pulmonary emphysema. Materials and methods Twenty-two patients with pulmonary emphysema underwent chest CT imaging using identical scanners with three different tube currents: 240, 120, and 60 mA. Scan data were converted to CT images using Adaptive Iterative Dose Reduction using Three Dimensional Processing (AIDR3D) and a conventional filtered-back projection mode. Thus, six scans with and without AIDR3D were generated per patient. All other scanning and reconstruction settings were fixed. The percent low attenuation area (LAA%; < −950 Hounsfield units) and the lung density 15th percentile were automatically measured using a commercial workstation. Comparisons of LAA% and 15th percentile results between scans with and without using AIDR3D were made by Wilcoxon signed-rank tests. Associations between body weight and measurement errors among these scans were evaluated by Spearman rank correlation analysis. Results Overall, scan series without AIDR3D had higher LAA% and lower 15th percentile values than those with AIDR3D at each tube current (P<0.0001). For scan series without AIDR3D, lower tube currents resulted in higher LAA% values and lower 15th percentiles. The extent of emphysema was significantly different between each pair among scans when not using AIDR3D (LAA%, P<0.0001; 15th percentile, P<0.01), but was not significantly different between each pair among scans when using AIDR3D. On scans without using AIDR3D, measurement errors between different tube current settings were significantly correlated with patients’ body weights (P<0.05), whereas these errors between scans when using AIDR3D were insignificantly or minimally correlated with body weight. Conclusion The extent of emphysema was more consistent across different tube currents when CT scans were converted to CT images using AIDR3D than using a conventional filtered-back projection method.
Collapse
Affiliation(s)
- Tsuneo Yamashiro
- Department of Radiology, Graduate School of Medical Science, University of the Ryukyus, Nishihara, Okinawa, Japan
| | - Tetsuhiro Miyara
- Department of Radiology, Graduate School of Medical Science, University of the Ryukyus, Nishihara, Okinawa, Japan
| | - Osamu Honda
- Department of Radiology, Osaka University Graduate School of Medicine, Suita, Osaka, Japan
| | - Noriyuki Tomiyama
- Department of Radiology, Osaka University Graduate School of Medicine, Suita, Osaka, Japan
| | - Yoshiharu Ohno
- Department of Radiology, Kobe University Graduate School of Medicine, Kobe, Hyogo, Japan
| | - Satoshi Noma
- Department of Radiology, Tenri Hospital, Tenri, Nara, Japan
| | - Sadayuki Murayama
- Department of Radiology, Graduate School of Medical Science, University of the Ryukyus, Nishihara, Okinawa, Japan
| |
Collapse
|
34
|
Abstract
Lung diseases cause significant morbidity and mortality and lead to high healthcare utilization. However, few lung disease-specific biomarkers are available to accurately monitor disease activity for the purposes of clinical management or drug development. Advances in cross-modal imaging technologies, such as combined positron emission tomography (PET) and magnetic resonance (MR) imaging scanners and PET or single-photon emission computed tomography (SPECT) combined with computed tomography (CT), may aid in the development of noninvasive, molecular-based biomarkers for lung disease. However, the lungs pose particular challenges in obtaining accurate quantification of imaging data due to the low density of the organ and breathing motion. This review covers the basic physics underlying PET, SPECT, CT, and MR lung imaging and presents technical considerations for multimodal imaging with regard to PET and SPECT quantification. It also includes a brief review of the current and potential clinical applications for these hybrid imaging technologies.
Collapse
Affiliation(s)
- Delphine L Chen
- Department of Internal Medicine, Washington University School of Medicine, St. Louis, MO, USA. Division of Radiological Sciences and Nuclear Medicine, Mallinckrodt Institute of Radiology, Campus Box 8225, 510 S. Kingshighway Blvd, St. Louis, MO 63110, USA
| | - Paul E Kinahan
- Department of Radiology and Bioengineering and Physics, University of Washington Medical Center, Seattle, WA, USA
| |
Collapse
|