1
|
Cambronero S, Dupré A, Mastier C, Chen Y, Hamelin O, Melodelima D. Intraoperative HIFU ablation of the liver at the hepatocaval confluence as adjunct to surgery: Preliminary animal experiments. ULTRASONICS 2024; 148:107556. [PMID: 39719790 DOI: 10.1016/j.ultras.2024.107556] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 10/07/2024] [Revised: 12/11/2024] [Accepted: 12/13/2024] [Indexed: 12/26/2024]
Abstract
Treating colorectal liver metastases (CLMs) located at the hepatocaval confluence with surgery is challenging due to its complexity and associated high risks of perioperative mortality and morbidity. Moreover, thermal ablation techniques are sensitive to the "heat-sink" effect, which reduces their efficacy when tumors are in contact with major blood vessels. In this study we evaluated the feasibility and safety of an intraoperative high-intensity focused ultrasound (HIFU) device for destroying liver tissue volumes sufficiently large to consider treating CLMs at the hepatocaval confluence. Experiments were conducted on six pigs that were followed up to 19 days after the treatment. One HIFU ablation in each animal was created using a 370 s exposure at 100 W. Homogeneous HIFU ablations of liver tissues were safely created at the hepatocaval confluence around the hepatic veins (HVs) in all animals. The targeted HVs were similar to those of humans, with an average diameter of 9.1 ± 1.4 mm. The longest and shortest axes of the HIFU ablations were on average 44.5 ± 11.5 mm and 26.7 ± 4.9 mm, respectively. These values indicate that this device could destroy CLMs up to 2 cm in diameter. Doppler acquisitions, MRI and histological analysis confirmed that HIFU ablations were in contact with the inferior vena cava and extended to the HV wall and that blood flow was maintained. This in vivo preclinical study showed that intraoperative HIFU destruction of liver tissues at the hepatocaval confluence under Doppler ultrasound guidance could therefore represent a new therapeutic option for CLMs.
Collapse
Affiliation(s)
- Sophie Cambronero
- LabTAU, INSERM, Centre Leon Berard, Universite Lyon 1, F-69003 LYON, France
| | - Aurélien Dupré
- LabTAU, INSERM, Centre Leon Berard, Universite Lyon 1, F-69003 LYON, France; Centre Leon Berard, F-69008 LYON, France
| | | | - Yao Chen
- Centre Leon Berard, F-69008 LYON, France
| | | | - David Melodelima
- LabTAU, INSERM, Centre Leon Berard, Universite Lyon 1, F-69003 LYON, France.
| |
Collapse
|
2
|
Zhou Y, Gong X, You Y. In vivo evaluation of focused ultrasound ablation surgery (FUAS)-induced coagulation using echo amplitudes of the therapeutic focused ultrasound transducer. Int J Hyperthermia 2024; 41:2325477. [PMID: 38439505 DOI: 10.1080/02656736.2024.2325477] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/15/2024] [Accepted: 02/26/2024] [Indexed: 03/06/2024] Open
Abstract
OBJECTIVE Monitoring sensitivity of sonography in focused ultrasound ablation surgery (FUAS) is limited (no hyperechoes in ∼50% of successful coagulation in uterine fibroids). A more accurate and sensitive approach is required. METHOD The echo amplitudes of the focused ultrasound (FUS) transducer in a testing mode (short pulse duration and low power) were found to correlate with the ex vivo coagulation. To further evaluate its coagulation prediction capabilities, in vivo experiments were carried out. The liver, kidney, and leg muscles of three adult goats were treated using clinical FUAS settings, and the echo amplitude of the FUS transducer and grayscale in sonography before and after FUAS were collected. On day 7, animals were sacrificed humanely, and the treated tissues were dissected to expose the lesion. Echo amplitude changes and lesion areas were analyzed statistically, as were the coagulation prediction metrics. RESULTS The echo amplitude changes of the FUS transducer correlate well with the lesion areas in the liver (R = 0.682). Its prediction in accuracy (94.4% vs. 50%), sensitivity (92.9% vs. 35.7%), and negative prediction (80% vs. 30.8%) is better than sonography, but similar in specificity (80% vs. 100%) and positive prediction (100% vs. 100%). In addition, the correlation between tissue depth and the lesion area is not good (|R| < 0.2). Prediction performances in kidney and leg muscles are similar. CONCLUSION The FUS echo amplitudes are sensitive to the tissue properties and their changes after FUAS. They are sensitive and reliable in evaluating and predicting FUAS outcomes.
Collapse
Affiliation(s)
- Yufeng Zhou
- State Key Laboratory of Ultrasound in Medicine and Engineering, College of Biomedical Engineering, Chongqing Medical University, Chongqing, China
- Chongqing Key Laboratory of Biomedical Engineering, Chongqing Medical University, Chongqing, China
- National Medical Products Administration (NMPA) Key Laboratory for Quality Evaluation of Ultrasonic Surgical Equipment, Wuhan, Hubei, China
| | - Xiaobo Gong
- Research and Development, National Engineering Research Center of Ultrasound Medicine, Chongqing, China
| | - Yaqing You
- Research and Development, National Engineering Research Center of Ultrasound Medicine, Chongqing, China
| |
Collapse
|
3
|
Delattre V, Cambronero S, Chen Y, Haar GT, Rivens I, Polton G, Lafon C, Melodelima D. In vivo exposure of the bladder using a non-invasive high intensity focused ultrasound toroidal transducer. ULTRASONICS 2024; 138:107239. [PMID: 38211366 DOI: 10.1016/j.ultras.2024.107239] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 08/31/2023] [Revised: 11/15/2023] [Accepted: 01/01/2024] [Indexed: 01/13/2024]
Abstract
A toroidal high-intensity focused ultrasound (HIFU) transducer was used to expose normal bladder wall tissues non-invasively in vivo in a porcine model in order to investigate the potential to treat bladder tumors. The transducer was divided into 32 concentric rings with equal surface areas, operating at 2.5 MHz. Eight animals were split into two groups of 4. In the first group, post-mortem evaluation was performed immediately after ultrasound exposure. In the second group, animals survived for up to seven days before post-mortem evaluation. The ultrasound imaging guided HIFU device was hand-held during the procedure using optical tracking to ensure correct targeting. One thermal lesion in each animal was created using a 40 s exposure at 80 acoustic Watts (free-field) in the trigone region of the bladder wall. The average (±Standard Deviation) abdominal wall and bladder wall thicknesses were 10.3 ± 1.4 mm and 1.1 ± 0.4 mm respectively. The longest and shortest axes of the HIFU ablations were 7.7 ± 2.9 mm and 6.0 ± 1.8 mm, respectively, resulting in an ablation of the whole thickness of the bladder wall in most cases. Ablation were performed at an average depth (distance from the skin surface to the centre of the HIFU lesion) of 42.5 ± 3.8 mm and extended throughout the thickness of the bladder. There were two cases of injury to tissues immediately adjacent to the bladder wall but without signs of perforation, as confirmed by histological analysis. Non-invasive HIFU ablation using a hand-held toroidal transducer was successfully performed to destroy regions of the bladder wall in vivo.
Collapse
Affiliation(s)
- Victor Delattre
- LabTAU, INSERM, Centre Léon Bérard, Université Claude Bernard Lyon 1, F-69003, Lyon, France.
| | - Sophie Cambronero
- LabTAU, INSERM, Centre Léon Bérard, Université Claude Bernard Lyon 1, F-69003, Lyon, France
| | - Yao Chen
- LabTAU, INSERM, Centre Léon Bérard, Université Claude Bernard Lyon 1, F-69003, Lyon, France
| | - Gail Ter Haar
- Joint Department of Physics, Institute of Cancer Research and Royal Marsden Hospital NHS Trust, Sutton, Surrey, UK
| | - Ian Rivens
- Joint Department of Physics, Institute of Cancer Research and Royal Marsden Hospital NHS Trust, Sutton, Surrey, UK
| | - Gerry Polton
- North Downs Specialist Referrals, Bletchingley, Surrey, UK
| | - Cyril Lafon
- LabTAU, INSERM, Centre Léon Bérard, Université Claude Bernard Lyon 1, F-69003, Lyon, France; Joint Department of Physics, Institute of Cancer Research and Royal Marsden Hospital NHS Trust, Sutton, Surrey, UK
| | - David Melodelima
- LabTAU, INSERM, Centre Léon Bérard, Université Claude Bernard Lyon 1, F-69003, Lyon, France
| |
Collapse
|
4
|
Wu Y, Guo J, Peng W. Application of the IDEAL framework in hepatopancreatobiliary surgery: a review of the literature. Langenbecks Arch Surg 2023; 409:20. [PMID: 38153558 DOI: 10.1007/s00423-023-03211-w] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/09/2023] [Accepted: 12/20/2023] [Indexed: 12/29/2023]
Abstract
PURPOSE To evaluate every stage of surgical innovation and generate high-quality research evidence, the IDEAL (Idea, Development, Exploration, Assessment, Long-term study) framework was developed. This study aimed to explore the application of the IDEAL framework in hepatopancreatobiliary surgery and identify factors limiting its dissemination. METHODS We conducted a citation search of 8 core IDEAL framework articles in PubMed, Embase, Web of Science, and Scopus databases from 2009 to 2022. Two independent reviewers screened and selected articles related to hepatopancreatobiliary surgery. RESULTS A total of 1621 articles were identified through citation search. Following screening, 132 articles were finally retained, including 75 original studies (57%) and 57 secondary studies (43%). Of the original studies, only 10 articles (13%) accurately applied the IDEAL framework in methodology, distributed as follows: 1 in pre-IDEAL stage (0), 2 in Idea stage (1), 7 in Development stage (2a), 1 in Exploration stage (2b), and no articles in Assessment and Long-term study stages (3, 4). In the secondary studies, 36 articles (63%) mentioned and discussed the IDEAL framework, and all supported its application. CONCLUSIONS The application of the IDEAL framework in hepatopancreatobiliary surgery is increasingly widespread, as evidenced by its substantial citation in numerous articles. However, the utilization of the IDEAL framework remains predominantly confined to the early stages of innovation in hepatopancreatobiliary surgery, coupled with instances of misapplication stemming from insufficient comprehension of the framework. Further efforts are necessary to extend the impact of the IDEAL framework and provide surgeons with comprehensive guidance for its judicious implementation.
Collapse
Affiliation(s)
- Youwei Wu
- Division of Liver Surgery, Department of General Surgery, West China Hospital, Sichuan University, Chengdu, 610041, China
| | - Jiulin Guo
- Department of Information, West China Hospital, Sichuan University, Chengdu, China
| | - Wei Peng
- Division of Liver Surgery, Department of General Surgery, West China Hospital, Sichuan University, Chengdu, 610041, China.
- Chinese Evidence-Based Medicine Center, West China Hospital, Sichuan University, Chengdu, China.
| |
Collapse
|
5
|
Dupré A, Rivoire M, Metzger S, Cropet C, Vincenot J, Peyrat P, Chen Y, Pérol D, Melodelima D. Intra-operative High-Intensity Focused Ultrasound in Patients With Colorectal Liver Metastases: A Prospective Ablate-and-Resect Study. ULTRASOUND IN MEDICINE & BIOLOGY 2023; 49:1845-1851. [PMID: 37268553 DOI: 10.1016/j.ultrasmedbio.2023.04.010] [Citation(s) in RCA: 2] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 01/31/2023] [Revised: 04/07/2023] [Accepted: 04/21/2023] [Indexed: 06/04/2023]
Abstract
OBJECTIVE High-intensity focused ultrasound (HIFU) is a recent, non-ionizing and non-invasive technology of focal destruction. Independence from the heat-sink effect of blood flow makes HIFU an interesting technique for focal ablation of liver tumors. Current available technology is based on extracorporeal treatment that limits use of HIFU for the treatment of liver tumors, as elementary ablations are small and must be juxtaposed to treat tumors, resulting in long-duration treatment. We developed an HIFU probe with toroidal technology, which increases the volume of ablation, for intra-operative use, and we assessed the feasibility and efficacy of this device in patients with colorectal liver metastasis (CLM) measuring less than 30 mm. METHODS This study was an ablate-and-resect, prospective, single-center, phase II study. All ablations were performed in the area of liver scheduled for liver resection to avoid loss of chance of recovery. The primary objective was to ablate CLM with safety margins (>5 mm). RESULTS Between May 2014 and July 2020, 15 patients were enrolled and 24 CLM were targeted. The HIFU ablation time was 370 s. In total, 23 of 24 CLM were successfully treated (95.8%). No damage occurred to extrahepatic tissues. HIFU ablations were oblate shaped with an average long axis of 44.3 ± 6.1 mm and an average shortest axis of 35.9 ± 6.7 mm. On pathological examination, the average diameter of the treated metastasis was 12.2 ± 4.8 mm. CONCLUSION Intra-operative HIFU can safely and accurately produce large ablations in 6 min with real-time guidance (ClinicalTrials.gov identifier: NCT01489787).
Collapse
Affiliation(s)
- Aurélien Dupré
- Department of Surgical Oncology, Centre Léon Bérard, Lyon, France; LabTAU, INSERM, Université Lyon 1, Centre Léon Bérard, Lyon, France.
| | - Michel Rivoire
- Department of Surgical Oncology, Centre Léon Bérard, Lyon, France; LabTAU, INSERM, Université Lyon 1, Centre Léon Bérard, Lyon, France
| | | | - Claire Cropet
- DRCI, Biostatistics Unit, Centre Léon Bérard, Lyon, France
| | - Jérémy Vincenot
- LabTAU, INSERM, Université Lyon 1, Centre Léon Bérard, Lyon, France
| | - Patrice Peyrat
- Department of Surgical Oncology, Centre Léon Bérard, Lyon, France
| | - Yao Chen
- Department of Surgical Oncology, Centre Léon Bérard, Lyon, France
| | - David Pérol
- DRCI, Biostatistics Unit, Centre Léon Bérard, Lyon, France
| | - David Melodelima
- LabTAU, INSERM, Université Lyon 1, Centre Léon Bérard, Lyon, France
| |
Collapse
|
6
|
Cambronero S, Dupré A, Mastier C, Melodelima D. Non-invasive High-Intensity Focused Ultrasound Treatment of Liver Tissues in an In Vivo Porcine Model: Fast, Large and Safe Ablations Using a Toroidal Transducer. ULTRASOUND IN MEDICINE & BIOLOGY 2023; 49:212-224. [PMID: 36441030 DOI: 10.1016/j.ultrasmedbio.2022.08.015] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 03/30/2022] [Revised: 07/30/2022] [Accepted: 08/28/2022] [Indexed: 06/16/2023]
Abstract
A toroidal high-intensity focused ultrasound (HIFU) transducer was used to non-invasively treat liver tissues in vivo in a pig model. The transducer was divided into 32 concentric rings with equal surface areas operating at 2.5 MHz. First, attenuation of skin, fat, muscle and liver tissues was measured in fresh animal samples to adjust the energy delivered to the focal zone. Then, 8 animals were included in the present protocol and placed in a dorsal decubitus proclive position at an angle of 15°. The device was held by hand, and sonications were performed during apnea. Two thermal HIFU lesions were created in 40 s in each animal. The average abdominal wall thickness was 14.8 ± 1.3 mm (12.5-17.6 mm). The longest and shortest axes of the HIFU ablations were 20.9 ± 6.3 mm (14.0-33.7 mm) and 14.2 ± 5.5 mm (7.0-22.0 mm), respectively. All HIFU lesions were visible on sonograms. The correlation between the dimensions of the HIFU lesions observed on sonograms and those obtained during gross examination was r = 0.84. Creating large and fast ablations with reliable ultrasound imaging guidance in the liver using this handheld device may represent a new therapeutic option for patients with liver tumors.
Collapse
Affiliation(s)
| | - Aurélien Dupré
- LabTAU, INSERM, Centre Léon Bérard, Université Lyon, Lyon, France; Centre Léon Bérard, Lyon, France
| | | | - David Melodelima
- LabTAU, INSERM, Centre Léon Bérard, Université Lyon, Lyon, France
| |
Collapse
|
7
|
Geoghegan R, Ter Haar G, Nightingale K, Marks L, Natarajan S. Methods of monitoring thermal ablation of soft tissue tumors - A comprehensive review. Med Phys 2022; 49:769-791. [PMID: 34965307 DOI: 10.1002/mp.15439] [Citation(s) in RCA: 23] [Impact Index Per Article: 7.7] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/12/2020] [Revised: 11/30/2020] [Accepted: 12/15/2021] [Indexed: 11/12/2022] Open
Abstract
Thermal ablation is a form of hyperthermia in which oncologic control can be achieved by briefly inducing elevated temperatures, typically in the range 50-80°C, within a target tissue. Ablation modalities include high intensity focused ultrasound, radiofrequency ablation, microwave ablation, and laser interstitial thermal therapy which are all capable of generating confined zones of tissue destruction, resulting in fewer complications than conventional cancer therapies. Oncologic control is contingent upon achieving predefined coagulation zones; therefore, intraoperative assessment of treatment progress is highly desirable. Consequently, there is a growing interest in the development of ablation monitoring modalities. The first section of this review presents the mechanism of action and common applications of the primary ablation modalities. The following section outlines the state-of-the-art in thermal dosimetry which includes interstitial thermal probes and radiologic imaging. Both the physical mechanism of measurement and clinical or pre-clinical performance are discussed for each ablation modality. Thermal dosimetry must be coupled with a thermal damage model as outlined in Section 4. These models estimate cell death based on temperature-time history and are inherently tissue specific. In the absence of a reliable thermal model, the utility of thermal monitoring is greatly reduced. The final section of this review paper covers technologies that have been developed to directly assess tissue conditions. These approaches include visualization of non-perfused tissue with contrast-enhanced imaging, assessment of tissue mechanical properties using ultrasound and magnetic resonance elastography, and finally interrogation of tissue optical properties with interstitial probes. In summary, monitoring thermal ablation is critical for consistent clinical success and many promising technologies are under development but an optimal solution has yet to achieve widespread adoption.
Collapse
Affiliation(s)
- Rory Geoghegan
- Department of Urology, University of California Los Angeles, Los Angeles, California, USA
| | - Gail Ter Haar
- Department of Physics, Institute of Cancer Research, University of London, Sutton, UK
| | - Kathryn Nightingale
- Department of Biomedical Engineering, Duke University, Durham, North Carolina, USA
| | - Leonard Marks
- Department of Urology, University of California Los Angeles, Los Angeles, California, USA
| | - Shyam Natarajan
- Departments of Urology & Bioengineering, University of California Los Angeles, Los Angeles, California, USA
| |
Collapse
|
8
|
Cilleros C, Dupré A, Chen Y, Vincenot J, Rivoire M, Melodelima D. Intraoperative HIFU Ablation of the Pancreas Using a Toroidal Transducer in a Porcine Model. The First Step towards a Clinical Treatment of Locally Advanced Pancreatic Cancer. Cancers (Basel) 2021; 13:6381. [PMID: 34945001 PMCID: PMC8699564 DOI: 10.3390/cancers13246381] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/03/2021] [Revised: 12/13/2021] [Accepted: 12/16/2021] [Indexed: 12/20/2022] Open
Abstract
Apart from palliative chemotherapy, no other therapy has been proven effective for the treatment of locally advanced pancreatic tumors. In this study, an intraoperative high-intensity focused ultrasound (HIFU) device was tested in vivo to demonstrate the feasibility of treating the pancreatic parenchyma and tissues surrounding the superior mesenteric vessels prior to clinical translation of this technique. Twenty pigs were included and treated using a HIFU device equipped with a toroidal transducer and an integrated ultrasound imaging probe. Treatments were performed with energy escalation (from 30 kJ to 52 kJ). All treatments resulted in visible (macroscopically and in ultrasound images) homogeneous thermal damage, which was confirmed by histology. The dimensions of thermal lesions measured in ultrasound images and those measured macroscopically were correlated (r = 0.82, p < 0.05). No arterial spasms or occlusion were observed at the lowest energy setting. Temporary spasm of the peripancreatic artery was observed when using an energy setting greater than 30 kJ. The possibility of treating the pancreas and tissues around mesenteric vessels without vascular thrombosis holds great promise for the treatment of locally advanced pancreatic cancers. If clinically successful, chemotherapy followed by HIFU treatment could rapidly become a novel treatment option for locally advanced pancreatic cancer.
Collapse
Affiliation(s)
- Celia Cilleros
- LabTAU, INSERM, Centre Léon Bérard, Université Lyon 1, Univ Lyon, F-69003 Lyon, France; (C.C.); (A.D.); (Y.C.); (M.R.)
- EDAP TMS, 4 Rue du Dauphiné, F-69120 Vaulx-en-Velin, France;
| | - Aurélien Dupré
- LabTAU, INSERM, Centre Léon Bérard, Université Lyon 1, Univ Lyon, F-69003 Lyon, France; (C.C.); (A.D.); (Y.C.); (M.R.)
| | - Yao Chen
- LabTAU, INSERM, Centre Léon Bérard, Université Lyon 1, Univ Lyon, F-69003 Lyon, France; (C.C.); (A.D.); (Y.C.); (M.R.)
| | - Jeremy Vincenot
- EDAP TMS, 4 Rue du Dauphiné, F-69120 Vaulx-en-Velin, France;
| | - Michel Rivoire
- LabTAU, INSERM, Centre Léon Bérard, Université Lyon 1, Univ Lyon, F-69003 Lyon, France; (C.C.); (A.D.); (Y.C.); (M.R.)
| | - David Melodelima
- LabTAU, INSERM, Centre Léon Bérard, Université Lyon 1, Univ Lyon, F-69003 Lyon, France; (C.C.); (A.D.); (Y.C.); (M.R.)
| |
Collapse
|
9
|
Torres-Jiménez J, Esteban-Villarrubia J, Ferreiro-Monteagudo R, Carrato A. Local Treatments in the Unresectable Patient with Colorectal Cancer Metastasis: A Review from the Point of View of the Medical Oncologist. Cancers (Basel) 2021; 13:5938. [PMID: 34885047 PMCID: PMC8656541 DOI: 10.3390/cancers13235938] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/04/2021] [Revised: 11/18/2021] [Accepted: 11/21/2021] [Indexed: 12/12/2022] Open
Abstract
For patients with isolated liver metastases from colorectal cancer who are not candidates for potentially curative resections, non-surgical local treatments may be useful. Non-surgical local treatments are classified according to how the treatment is administered. Local treatments are applied directly on hepatic parenchyma, such as radiofrequency, microwave hyperthermia and cryotherapy. Locoregional therapies are delivered through the hepatic artery, such as chemoinfusion, chemoembolization or selective internal radiation with Yttrium 90 radioembolization. The purpose of this review is to describe the different interventional therapies that are available for these patients in routine clinical practice, the most important clinical trials that have tried to demonstrate the effectiveness of each therapy and recommendations from principal medical oncologic societies.
Collapse
Affiliation(s)
- Javier Torres-Jiménez
- Medical Oncology Department, University Hospital Ramon y Cajal, 28034 Madrid, Spain; (J.E.-V.); (R.F.-M.)
| | - Jorge Esteban-Villarrubia
- Medical Oncology Department, University Hospital Ramon y Cajal, 28034 Madrid, Spain; (J.E.-V.); (R.F.-M.)
| | - Reyes Ferreiro-Monteagudo
- Medical Oncology Department, University Hospital Ramon y Cajal, 28034 Madrid, Spain; (J.E.-V.); (R.F.-M.)
| | - Alfredo Carrato
- Medical Oncology Department, Ramón y Cajal Health Research Institute (IRYCIS), CIBERONC, Alcalá University, University Hospital Ramon y Cajal, 28034 Madrid, Spain;
| |
Collapse
|
10
|
Sanchez M, Barrere V, Treilleux I, Chopin N, Melodelima D. Development of a noninvasive HIFU treatment for breast adenocarcinomas using a toroidal transducer based on preliminary attenuation measurements. ULTRASONICS 2021; 115:106459. [PMID: 33990009 DOI: 10.1016/j.ultras.2021.106459] [Citation(s) in RCA: 10] [Impact Index Per Article: 2.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 07/21/2020] [Revised: 01/21/2021] [Accepted: 05/04/2021] [Indexed: 06/12/2023]
Abstract
Breast cancer is the most commonly diagnosed type of cancer among women. For the last fifteen years, treatments that are less invasive than lumpectomy, such as high-intensity focused ultrasound (HIFU) therapy, have been developed, with encouraging results. In this study, a toroidal HIFU transducer was used to create lesions of at least 2 cm in diameter within less than one minute of treatment. The toroidal HIFU transducer created two focal zones that led to large, fast and homogeneous ablations (10.5 cc/min). The experiments were conducted in 30 human samples of normal breast tissues recovered from mastectomies to measure acoustic attenuation (N = 30), and then, HIFU lesions were created (N = 15). Eight HIFU ablations were performed to evaluate the reproducibility of the lesions. HIFU lesions were created in 45 s with a toroidal HIFU transducer working at 2.5 MHz. The longest and shortest axes of the HIFU lesions were 21.7 ± 3.1 mm and 23.5 ± 3.3 mm respectively, corresponding to an average volume of 7.3 ± 1.4 cm3. These HIFU lesions were performed at an average depth of 19.0 ± 1.5 mm, while the integrity of the skin was preserved. The HIFU-treated breast tissues had a higher level of attenuation (0.57 ± 0.11 Np.cm-1.MHz-1) when compared to the untreated tissues (0.21 ± 0.04 Np.cm-1.MHz-1). This study shows the feasibility of a fast and fully noninvasive treatment using a toroidal transducer for breast tumors measuring up to 15 mm in diameter.
Collapse
Affiliation(s)
- M Sanchez
- LabTAU, INSERM, Centre Léon Bérard, Université Lyon 1, Univ Lyon, F-69003 Lyon, France
| | - V Barrere
- LabTAU, INSERM, Centre Léon Bérard, Université Lyon 1, Univ Lyon, F-69003 Lyon, France
| | | | - N Chopin
- Centre Léon Bérard, F-69008 Lyon, France
| | - D Melodelima
- LabTAU, INSERM, Centre Léon Bérard, Université Lyon 1, Univ Lyon, F-69003 Lyon, France.
| |
Collapse
|
11
|
Barrere V, Sanchez M, Cambronero S, Dupré A, Rivoire M, Melodelima D. Evaluation of Ultrasonic Attenuation in Primary and Secondary Human Liver Tumors and Its Potential Effect on High-Intensity Focused Ultrasound Treatment. ULTRASOUND IN MEDICINE & BIOLOGY 2021; 47:1761-1774. [PMID: 33895037 DOI: 10.1016/j.ultrasmedbio.2021.03.014] [Citation(s) in RCA: 6] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 06/15/2020] [Revised: 03/15/2021] [Accepted: 03/17/2021] [Indexed: 06/12/2023]
Abstract
Primary and secondary liver tumors are completely different diseases but are usually treated similarly using high-intensity focused ultrasound (HIFU). However, the acoustic parameters of these tissues are not well documented. In this study, attenuation coefficients were evaluated in fresh primary (N = 8) and secondary (N = 13) human liver tumor samples recovered by hepatectomy. The average attenuation coefficients of the primary and secondary liver tumors were 0.10 ± 0.03 and 0.20 ± 0.04 Np/cm/MHz, respectively. The average attenuation coefficients of the liver tissue surrounding the primary and secondary tumors were 0.16 ± 0.07 and 0.07 ± 0.02 Np/cm/MHz, respectively. Numerical simulations performed using these values revealed that completely different HIFU ablation patterns were created in primary and secondary liver tumors using the same exposure parameters. The dimensions of a typical HIFU lesion were two times larger in secondary liver tumors than in primary tumors. HIFU treatment parameters should be set properly according to the acoustic properties of the diseased liver tissue.
Collapse
Affiliation(s)
- Victor Barrere
- LabTAU, INSERM, Centre Léon Bérard, Université Lyon 1, Univ Lyon, Lyon, France
| | - Marine Sanchez
- LabTAU, INSERM, Centre Léon Bérard, Université Lyon 1, Univ Lyon, Lyon, France
| | - Sophie Cambronero
- LabTAU, INSERM, Centre Léon Bérard, Université Lyon 1, Univ Lyon, Lyon, France
| | - Aurelien Dupré
- LabTAU, INSERM, Centre Léon Bérard, Université Lyon 1, Univ Lyon, Lyon, France
| | - Michel Rivoire
- LabTAU, INSERM, Centre Léon Bérard, Université Lyon 1, Univ Lyon, Lyon, France
| | - David Melodelima
- LabTAU, INSERM, Centre Léon Bérard, Université Lyon 1, Univ Lyon, Lyon, France.
| |
Collapse
|
12
|
The Italian Consensus on minimally invasive simultaneous resections for synchronous liver metastasis and primary colorectal cancer: A Delphi methodology. Updates Surg 2021; 73:1247-1265. [PMID: 34089501 DOI: 10.1007/s13304-021-01100-9] [Citation(s) in RCA: 33] [Impact Index Per Article: 8.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/03/2021] [Accepted: 05/12/2021] [Indexed: 12/17/2022]
Abstract
At the time of diagnosis synchronous colorectal cancer, liver metastases (SCRLM) account for 15-25% of patients. If primary tumour and synchronous liver metastases are resectable, good results may be achieved performing surgical treatment incorporated into the chemotherapy regimen. So far, the possibility of simultaneous minimally invasive (MI) surgery for SCRLM has not been extensively investigated. The Italian surgical community has captured the need and undertaken the effort to establish a National Consensus on this topic. Four main areas of interest have been analysed: patients' selection, procedures, techniques, and implementations. To establish consensus, an adapted Delphi method was used through as many reiterative rounds were needed. Systematic literature reviews were conducted according to the Preferred Reporting Items for Systematic Reviews and Meta-Analyses instructions. The Consensus took place between February 2019 and July 2020. Twenty-six Italian centres participated. Eighteen clinically relevant items were identified. After a total of three Delphi rounds, 30-tree recommendations reached expert consensus establishing the herein presented guidelines. The Italian Consensus on MI surgery for SCRLM indicates possible pathways to optimise the treatment for these patients as consensus papers express a trend that is likely to become shortly a standard procedure for clinical pictures still on debate. As matter of fact, no RCT or relevant case series on simultaneous treatment of SCRLM are available in the literature to suggest guidelines. It remains to be investigated whether the MI technique for the simultaneous treatment of SCRLM maintain the already documented benefit of the two separate surgeries.
Collapse
|
13
|
Development of a Simple In Vitro Artery Model and an Evaluation of the Impact of Pulsed Flow on High-Intensity Focused Ultrasound Ablation. Ing Rech Biomed 2021. [DOI: 10.1016/j.irbm.2020.11.004] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/22/2022]
|
14
|
Lafon C, Moore D, Eames MDC, Snell J, Drainville RA, Padilla F. Evaluation of Pseudorandom Sonications for Reducing Cavitation With a Clinical Neurosurgery HIFU Device. IEEE TRANSACTIONS ON ULTRASONICS, FERROELECTRICS, AND FREQUENCY CONTROL 2021; 68:1224-1233. [PMID: 33166253 DOI: 10.1109/tuffc.2020.3036774] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/11/2023]
Abstract
Transcranial high-intensity focused ultrasound is used in clinics for treating essential tremor (ET) and proposed for many other brain disorders. This promising treatment modality requires high energy resulting eventually in undesired cavitation and potential side effects. The goals of the present work were: 1) to evaluate the potential increase of the cavitation threshold using pseudorandom gated sonications and 2) to assess the heating capabilities with such sonications. The experiments were performed with the transcranial magnetic resonance (MR)-compatible ExAblate Neuro system (InSightec, Haifa, Israel) operating at a frequency of 670 kHz, either in continuous wave (CW) or with pseudorandom gated sonications of 50% duty cycle. Cavitation activity with the two types of sonications was compared using chemical dosimetry of hydroxyl radical production at the focus of the transducer, after propagation in water or through a human skull. Heating trials were performed in a hydrogel tissue-mimicking material embedded in a human skull to mimic a clinical situation. The temperature was measured by MR-thermometry when focusing at the geometrical focus and steering off focus up to 15 mm. Compared with CW sonications, the use of gated sonication did not affect the efficiency (60%) nor the steering abilities of the transducer. After propagation through a human skull, gated sonication required a higher pressure level (10 MPa) to initiate cavitation as compared with CW (5.8 MPa). Moreover, at equivalent acoustic power above the cavitation threshold, the level of cavitation activity initiated with gated sonications was much lower with gated sonication than with continuous sonications, almost half after propagation through water and one-third after propagation through a skull. This lowered cavitation activity may be attributed to a breaking of the dynamic of the bubbles moving from monochromatic to more broadband sonications and to the removal of residual cavitation nuclei between pulses with gated sonications. The heating capability was not affected by the gated sonications, and similar temperature increases were reached at focus with both types of sonications when sonicating at equivalent acoustic power, both in water or after propagation through a human skull (+15 °C at 325 W for 10 s). These data, acquired with a clinical system, suggest that gated sonication could be an alternative to continuous sonications when cavitation onset is an issue.
Collapse
|
15
|
Battais A, Barrère V, N'Djin WA, Dupré A, Rivoire M, Melodelima D. Fast and Selective Ablation of Liver Tumors by High-Intensity Focused Ultrasound Using a Toroidal Transducer Guided by Ultrasound Imaging: The Results of Animal Experiments. ULTRASOUND IN MEDICINE & BIOLOGY 2020; 46:3286-3295. [PMID: 32891425 DOI: 10.1016/j.ultrasmedbio.2020.08.001] [Citation(s) in RCA: 6] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 01/28/2020] [Revised: 07/31/2020] [Accepted: 08/02/2020] [Indexed: 06/11/2023]
Abstract
This study demonstrated that high-intensity focused ultrasound (HIFU) produced with an intra-operative toroidal-shaped transducer causes fast, selective liver tumor ablations in an animal model. The HIFU device is composed of 256 emitters working at 3 MHz. A 7.5 MHz ultrasound imaging probe centered on the HIFU transducer guided treatment. VX2 tumor segments (25 mg) were implanted into the right lateral liver lobes of 45 New Zealand rabbits. The animals were evenly divided into groups 1 (toroidal HIFU ablation), 2 (surgical resection) and 3 (untreated control). Therapeutic responses were evaluated with gross pathology and histology 11 d post-treatment. Toroidal transducer-produced HIFU ablation (average ablation rate 10.5 cc/min) allowed fast and homogeneous tumor treatment. Sonograms showed all ablations. VX2 tumors were completely coagulated and surrounded by safety margins without surrounding-organ secondary HIFU lesions. HIFU group tumor volumes at autopsy (39 mm3) were significantly lower than control group volumes (2610 mm3, p < 0.0001). HIFU group tumor metastasis (27%) was lower than resected (33%) and control (67%) group metastasis. Ultrasound imaging, gross pathology and histology results supported these outcomes. HIFU procedures had no complications. Rabbit liver tumor ablation using a toroidal HIFU transducer under ultrasound imaging guidance might therefore be an effective intra-operative treatment for localized liver metastases.
Collapse
Affiliation(s)
- Amélie Battais
- LabTAU, INSERM, Centre Léon Bérard, Université Lyon 1, Univ Lyon, F-69003, Lyon, France
| | - Victor Barrère
- LabTAU, INSERM, Centre Léon Bérard, Université Lyon 1, Univ Lyon, F-69003, Lyon, France
| | - W Apoutou N'Djin
- LabTAU, INSERM, Centre Léon Bérard, Université Lyon 1, Univ Lyon, F-69003, Lyon, France
| | - Aurélien Dupré
- LabTAU, INSERM, Centre Léon Bérard, Université Lyon 1, Univ Lyon, F-69003, Lyon, France
| | - Michel Rivoire
- LabTAU, INSERM, Centre Léon Bérard, Université Lyon 1, Univ Lyon, F-69003, Lyon, France
| | - David Melodelima
- LabTAU, INSERM, Centre Léon Bérard, Université Lyon 1, Univ Lyon, F-69003, Lyon, France.
| |
Collapse
|
16
|
Wen Y, Zhao S, Holmqvist A, Hahn-Stromberg V, Adell G, Holmlund B, Pathak S, Peng Z, Sun XF. Predictive Role of Biopsy Based Biomarkers for Radiotherapy Treatment in Rectal Cancer. J Pers Med 2020; 10:jpm10040168. [PMID: 33066317 PMCID: PMC7712120 DOI: 10.3390/jpm10040168] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/28/2020] [Revised: 10/01/2020] [Accepted: 10/09/2020] [Indexed: 12/30/2022] Open
Abstract
Background and Purpose: Radiation therapy has long been contemplated as an important mode in the treatment of rectal cancer. However, there are few ideal tools available for clinicians to make a radiotherapy decision at the time of diagnosis for rectal cancer. The purpose of this study was to assess whether biomarkers expressed in the biopsy could help to choose the suitable therapy and provide predictive and/or prognostic information. Experimental Design: In total, 30 biomarkers were analyzed in 219 biopsy samples before treatment to discover the possibility of using them as an indicator for radiotherapy selection, diagnosis, survival and recurrence. Results: Twenty-two biomarkers (COX2-RT, COX2-NonRT, etc.; 36.67%) had diagnostic value. For survival, four biomarkers (NFKBP65, p130, PINCH and PPAR) were significant in regulating gene promoter activity and overall survival, while four had a trend (AEG1, LOX, SATB1 and SIRT6). Three biomarkers (COX2, PINCH and WRAP53) correlated with disease-free survival, while eight had a trend (AEG1, COX2, Ki67, LOX, NFKBP65, PPAR and SATB1). Four biomarkers (COX2-RT, NFKBP65cyto-RT, P130cyto-NonRT and PPARcyto-RT) were independent prognostic factors for recurrence. NFKBP65 and SIRT6 were significantly correlated with lymph node metastasis regardless of radiation. Patients with high AEG1, LOX, NFKBP65, PPAR and SATB1 had or showed a positive trend for better survival after radiotherapy, while those with positive PINCH and WRAP53 expression would not benefit from radiotherapy. Conclusions: AEG1, LOX, NFKBP65cyto, PPAR and SATB1 could be used as indicators for choosing radiotherapy. COX2-RT, COX2-NonRT and some other biomarkers may provide additional help for diagnosis.
Collapse
Affiliation(s)
- Yugang Wen
- Department of General Surgery, Shanghai General Hospital, School of Medicine, Shanghai Jiaotong University, Shanghai 200080, China; (Y.W.); (S.Z.)
- Department of Oncology and Department of Biomedical and Clinical Sciences, Linköping University, SE-581 83 Linköping, Sweden; (A.H.); (G.A.); (B.H.)
| | - Senlin Zhao
- Department of General Surgery, Shanghai General Hospital, School of Medicine, Shanghai Jiaotong University, Shanghai 200080, China; (Y.W.); (S.Z.)
- Department of Oncology and Department of Biomedical and Clinical Sciences, Linköping University, SE-581 83 Linköping, Sweden; (A.H.); (G.A.); (B.H.)
| | - Annica Holmqvist
- Department of Oncology and Department of Biomedical and Clinical Sciences, Linköping University, SE-581 83 Linköping, Sweden; (A.H.); (G.A.); (B.H.)
| | | | - Gunnar Adell
- Department of Oncology and Department of Biomedical and Clinical Sciences, Linköping University, SE-581 83 Linköping, Sweden; (A.H.); (G.A.); (B.H.)
| | - Birgitta Holmlund
- Department of Oncology and Department of Biomedical and Clinical Sciences, Linköping University, SE-581 83 Linköping, Sweden; (A.H.); (G.A.); (B.H.)
| | - Surajit Pathak
- Faculty of Allied Health Sciences, Chettinad Academy of Research and Education, Kelambakkam, Chennai 603 103, India;
| | - Zhihai Peng
- Department of General Surgery, Shanghai General Hospital, School of Medicine, Shanghai Jiaotong University, Shanghai 200080, China; (Y.W.); (S.Z.)
- Correspondence: (Z.P.); (X.-F.S.); Tel.: +86-13761010066 (Z.P.); +46-10-1032066 (X.-F.S.)
| | - Xiao-Feng Sun
- Department of Oncology and Department of Biomedical and Clinical Sciences, Linköping University, SE-581 83 Linköping, Sweden; (A.H.); (G.A.); (B.H.)
- Correspondence: (Z.P.); (X.-F.S.); Tel.: +86-13761010066 (Z.P.); +46-10-1032066 (X.-F.S.)
| |
Collapse
|
17
|
Daunizeau L, Nguyen A, Le Garrec M, Chapelon JY, N'Djin WA. Robot-assisted ultrasound navigation platform for 3D HIFU treatment planning: Initial evaluation for conformal interstitial ablation. Comput Biol Med 2020; 124:103941. [PMID: 32818742 DOI: 10.1016/j.compbiomed.2020.103941] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/06/2020] [Revised: 07/19/2020] [Accepted: 07/27/2020] [Indexed: 10/23/2022]
Abstract
Interstitial Ultrasound-guided High Intensity Focused Ultrasound (USgHIFU) therapy has the potential to deliver ablative treatments which conform to the target tumor. In this study, a robot-assisted US-navigation platform has been developed for 3D US guidance and planning of conformal HIFU ablations. The platform was used to evaluate a conformal therapeutic strategy associated with an interstitial dual-mode USgHIFU catheter prototype (64 elements linear-array, measured central frequency f = 6.5 MHz), developed for the treatment of HepatoCellular Carcinoma (HCC). The platform included a 3D navigation environment communicating in real-time with an open research dual-mode US scanner/HIFU generator and a robotic arm, on which the USgHIFU catheter was mounted. 3D US-navigation was evaluated in vitro for guiding and planning conformal HIFU ablations using a tumor-mimic model in porcine liver. Tumor-mimic volumes were then used as targets for evaluating conformal HIFU treatment planning in simulation. Height tumor-mimics (ovoid- or disc-shaped, sizes: 3-29 cm3) were created and visualized in liver using interstitial 2D US imaging. Robot-assisted spatial manipulation of these images and real-time 3D navigation allowed reconstructions of 3D B-mode US images for accurate tumor-mimic volume estimation (relative error: 4 ± 5%). Sectorial and full-revolution HIFU scanning (angular sectors: 88-360°) could both result in conformal ablations of the tumor volumes, as soon as their radii remained ≤ 24 mm. The presented US navigation-guided HIFU procedure demonstrated advantages for developing conformal interstitial therapies in standard operative rooms. Moreover, the modularity of the developed platform makes it potentially useful for developing other HIFU approaches.
Collapse
Affiliation(s)
- L Daunizeau
- LabTAU, INSERM, Centre Léon Bérard, Université Lyon 1, Univ Lyon, F-69003, Lyon, France.
| | - A Nguyen
- LabTAU, INSERM, Centre Léon Bérard, Université Lyon 1, Univ Lyon, F-69003, Lyon, France
| | - M Le Garrec
- LabTAU, INSERM, Centre Léon Bérard, Université Lyon 1, Univ Lyon, F-69003, Lyon, France
| | - J Y Chapelon
- LabTAU, INSERM, Centre Léon Bérard, Université Lyon 1, Univ Lyon, F-69003, Lyon, France
| | - W A N'Djin
- LabTAU, INSERM, Centre Léon Bérard, Université Lyon 1, Univ Lyon, F-69003, Lyon, France
| |
Collapse
|
18
|
Yang T, Ng DM, Du N, He N, Dai X, Chen P, Wu F, Chen B, Fan X, Yan K, Zhou X, Dong M, Zheng Z, Gu L. HIFU for the treatment of difficult colorectal liver metastases with unsuitable indications for resection and radiofrequency ablation: a phase I clinical trial. Surg Endosc 2020; 35:2306-2315. [PMID: 32435962 DOI: 10.1007/s00464-020-07644-y] [Citation(s) in RCA: 16] [Impact Index Per Article: 3.2] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/08/2019] [Accepted: 05/13/2020] [Indexed: 12/15/2022]
Abstract
BACKGROUND The goal of this study is to evaluate the safety and efficacy of high intensity focused ultrasound (HIFU) for patients with colorectal liver metastases (CRLM) but were contraindicated for resection and radiofrequency ablation. METHODS Patients between 20 and 80 years of age with 1-3 liver metastases from colorectal cancer were selected. Included patients have had their primary lesions removed with no evidence of extrahepatic metastasis prior to the study. Ultrasound-guided HIFU was employed and target regions' ablation was achieved with repeated sonications from the deep to shallow regions of the tumors section by section. RESULTS Thirteen patients were enrolled. The most common adverse events (AEs) were pain (n = 8), followed by fatigue (n = 7), increased aspartate aminotransferase (AST) (n = 7), increased alanine aminotransferase (ALT) (n = 5), and skin edema (n = 4). No grade ≥ 3 AEs occurred and while most patients (76.9%) achieved a complete response, three patients achieved a partial response. The objective response rate was 100% after the first HIFU treatment. Nine patients relapsed but the tumors were mostly isolated to the liver (8/9). The median follow-up period was 25 months. The 2-year progression-free survival (PFS) was 16.7%, and the median PFS was 9 months. Notably, the 2-year overall survival (OS) was 77.8%, and the median OS was 25 months. CONCLUSION This study indicates that the HIFU treatment is safe, is able to achieve a good tumor response rate and long-term prognosis even when the foci were in high-risk locations, and should be considered for patients who were considered unsuitable for other local treatments.
Collapse
Affiliation(s)
- Tong Yang
- Department of Tumor HIFU Therapy, HwaMei Hospital, University of Chinese Academy of Sciences, Ningbo, Zhejiang, China
- Ningbo Institute of Life and Health Industry, University of Chinese Academy of Sciences, Haishu District, Northwest Street 41, Ningbo, 315010, Zhejiang, China
| | | | - Nannan Du
- The Second Clinical Medical College, Zhejiang Chinese Medical University, Hangzhou, Zhejiang, China
| | - Ning He
- Department of Tumor HIFU Therapy, HwaMei Hospital, University of Chinese Academy of Sciences, Ningbo, Zhejiang, China
| | - Xiaoyu Dai
- Department of Anus and Intestine Surgery, HwaMei Hospital, University of Chinese Academy of Sciences, Ningbo, Zhejiang, China
| | - Ping Chen
- Department of General Surgery, HwaMei Hospital, University of Chinese Academy of Sciences, Haishu District, Northwest Street 41, Ningbo, 315010, Zhejiang, China
| | - Feng Wu
- Department of General Surgery, HwaMei Hospital, University of Chinese Academy of Sciences, Haishu District, Northwest Street 41, Ningbo, 315010, Zhejiang, China
| | - Bo Chen
- Department of Medical Image, HwaMei Hospital, University of Chinese Academy of Sciences, Ningbo, Zhejiang, China
| | - Xiaoxiang Fan
- Department of Interventional Therapy, HwaMei Hospital, University of Chinese Academy of Sciences, Ningbo, Zhejiang, China
| | - Kun Yan
- Department of Medical Image, HwaMei Hospital, University of Chinese Academy of Sciences, Ningbo, Zhejiang, China
| | - Xinfeng Zhou
- Department of General Surgery, HwaMei Hospital, University of Chinese Academy of Sciences, Haishu District, Northwest Street 41, Ningbo, 315010, Zhejiang, China
| | - Mingjun Dong
- Department of Anus and Intestine Surgery, HwaMei Hospital, University of Chinese Academy of Sciences, Ningbo, Zhejiang, China
| | - Zhi Zheng
- Department of Tumor HIFU Therapy, HwaMei Hospital, University of Chinese Academy of Sciences, Ningbo, Zhejiang, China
| | - Lihu Gu
- Ningbo Institute of Life and Health Industry, University of Chinese Academy of Sciences, Haishu District, Northwest Street 41, Ningbo, 315010, Zhejiang, China.
- Key Laboratory of Diagnosis and Treatment of Digestive System Tumors of Zhejiang Province, Haishu District, Northwest Street 41, Ningbo, 315010, Zhejiang, China.
- Department of General Surgery, HwaMei Hospital, University of Chinese Academy of Sciences, Haishu District, Northwest Street 41, Ningbo, 315010, Zhejiang, China.
| |
Collapse
|
19
|
Vion-Bailly J, N'Djin WA, Suarez Castellanos IM, Mestas JL, Carpentier A, Chapelon JY. A causal study of the phenomenon of ultrasound neurostimulation applied to an in vivo invertebrate nervous model. Sci Rep 2019; 9:13738. [PMID: 31551448 PMCID: PMC6760187 DOI: 10.1038/s41598-019-50147-7] [Citation(s) in RCA: 10] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/11/2018] [Accepted: 09/04/2019] [Indexed: 11/10/2022] Open
Abstract
Focused ultrasound are considered to be a promising tool for the treatment of neurological conditions, overcoming the limitations of current neurostimulation techniques in terms of spatial resolution and invasiveness. Much evidence to support the feasibility of ultrasound activation of neurons at the systemic level has already been provided, but to this day, the biophysical mechanisms underlying ultrasound neurostimulation are still widely unknown. In order to be able to establish a clear and robust causality between acoustic parameters of the excitation and neurobiological characteristics of the response, it is necessary to work at the cellular level, or alternatively on very simple animal models. The study reported here responds to three objectives. Firstly, to propose a simple nervous model for the study of the ultrasound neurostimulation phenomenon, associated with a clear and simple experimental protocol. Secondly, to compare the characteristics of this model’s nervous response to ultrasound neurostimulation with its nervous response to mechanical and electrical stimulation. Thirdly, to study the role played by certain acoustic parameters in the success rate of the phenomenon of ultrasound stimulation. The feasibility of generating action potentials (APs) in the giant axons of an earthworm’s ventral nerve cord, using pulsed ultrasound stimuli (f = 1.1 MHz, Ncycles = 175–1150, PRF = 25–125 Hz, Npulses = 20, PA = 2.5–7.3 MPa), was demonstrated. The time of generation (TOG) of APs associated with ultrasound stimulation was found to be significantly shorter and more stable than the TOG associated with mechanical stimulation (p < 0.001). By applying a causal approach to interpret the results of this study, it was concluded that, in this model, the nervous response to focused ultrasound is initiated along the afferent neurons, in between the mechanosensors and the synaptic connections with the giant axons. Additionally, early results are provided, highlighting a trend for the success rate of ultrasound neurostimulation and number of APs triggered per response to increase with increasing pulse repetition frequency (p < 0.05 and p < 0.001, respectively), increasing pulse duration and increasing pulse amplitude.
Collapse
Affiliation(s)
- Jérémy Vion-Bailly
- LabTAU, INSERM, Centre Léon Bérard, Université Lyon 1, Univ Lyon, F-69003, Lyon, France.
| | - W Apoutou N'Djin
- LabTAU, INSERM, Centre Léon Bérard, Université Lyon 1, Univ Lyon, F-69003, Lyon, France
| | | | - Jean-Louis Mestas
- LabTAU, INSERM, Centre Léon Bérard, Université Lyon 1, Univ Lyon, F-69003, Lyon, France
| | - Alexandre Carpentier
- Assistance Publique Hôpitaux de Paris, Hôpital Pitié-Salpêtrière, Neurosurgery department, Paris, F-75013, France.,Sorbonne Université, Paris, F-75005, France
| | - Jean-Yves Chapelon
- LabTAU, INSERM, Centre Léon Bérard, Université Lyon 1, Univ Lyon, F-69003, Lyon, France
| |
Collapse
|
20
|
Caloone J, Barrere V, Sanchez M, Cambronero S, Huissoud C, Melodelima D. High-Intensity Focused Ultrasound Using a Toroidal Transducer as an Adjuvant Treatment for Placenta Accreta: A Preliminary Ex Vivo Study. Ing Rech Biomed 2019. [DOI: 10.1016/j.irbm.2019.05.008] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/12/2022]
|
21
|
Li M, Wan G, Yu H, Xiong W. High-intensity focused ultrasound inhibits invasion and metastasis of colon cancer cells by enhancing microRNA-124-mediated suppression of STAT3. FEBS Open Bio 2019; 9:1128-1136. [PMID: 30980700 PMCID: PMC6551491 DOI: 10.1002/2211-5463.12642] [Citation(s) in RCA: 7] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/31/2019] [Revised: 03/31/2019] [Accepted: 04/12/2019] [Indexed: 12/18/2022] Open
Abstract
Metastasis is the primary contributor to colorectal cancer mortality. High‐intensity focused ultrasound (HIFU) is an emerging technology for tumor therapy that exerts its effects through tumor ablation, mechanical disruption, and enhancement of immune responses. However, it remains unclear whether HIFU can influence tumor metastasis. Here, we examined the effect of HIFU on tumor metastasis of colorectal cancer cells and the underlying mechanisms. HIFU was observed to inhibit migration of HCT‐116 cells in vitro and suppress lung metastasis in a mouse model of colon cancer. In addition, HIFU up‐regulated microRNA (miR) ‐124 expression, which inhibited the activation of signal transducer and activator of transcription 3 (STAT3) and inhibited migration of HCT‐116 cells. Treatment with an inhibitor of miR‐124 reversed the effect of HIFU on cell migration. In conclusion, our results suggest that HIFU exerts anti‐metastatic effects in colon cancer, and this effect is possibly mediated via up‐regulation of miR‐124 and subsequent miR‐124‐mediated STAT3 suppression.
Collapse
Affiliation(s)
- Meiying Li
- Department of Ultrasound, Shanghai University of Traditional Chinese Medicine Affiliated PUTUO Hospital, China
| | - Guangsheng Wan
- Oncology Department of Traditional Chinese Medicine, Shanghai University of Traditional Chinese Medicine Affiliated PUTUO Hospital, China
| | - Hongjie Yu
- Oncology Department of Traditional Chinese Medicine, Shanghai University of Traditional Chinese Medicine Affiliated PUTUO Hospital, China
| | - Wei Xiong
- Department of Ultrasound, Shanghai University of Traditional Chinese Medicine Affiliated PUTUO Hospital, China
| |
Collapse
|
22
|
Ouyang H, Ma W, Zhang T, Liu F, Zhao L, Fang M, Quan M, Pan Z. Systemic chemotherapy in combination with liver-directed therapy improves survival in patients with pancreatic adenocarcinoma and synchronous liver metastases. Pancreatology 2018; 18:983-989. [PMID: 30287168 DOI: 10.1016/j.pan.2018.09.015] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 02/26/2018] [Revised: 09/27/2018] [Accepted: 09/28/2018] [Indexed: 12/11/2022]
Abstract
OBJECTIVES We investigated whether the combination of systemic chemotherapy (SCT) and liver-directed therapy (LDT) was superior to chemotherapy alone for patients with pancreatic adenocarcinoma and synchronous liver metastases (PACLM). METHODS We reviewed the medical records of 184 patients treated with SCT ± LDT at Tianjin Medical University Cancer Hospital from 2001 to 2015. Overall survival (OS) was the primary end-point. The role of treatment modality and other clinical factors was evaluated by univariate and Cox regression analyses. RESULTS Sixty-four (34.8%) patients in the SCT-LDT group and 120 (65.2%) patients in the SCT group were included in the analysis. Baseline clinical characteristics were similar between the groups (all P > 0.05). The median survival was 8.7 months in the SCT-LDT group and was 6.3 months in the SCT group. The 0.5-, 1-, 2- and 3-year survival rates were 67.2%, 33.4%, 13.3% and 8.9%, respectively, after SCT-LDT, and were 54.9%, 19.0%, 4.5% and 2.0%, respectively, after SCT (P = 0.01). Primary tumor size, ascites, and treatment modality (SCT + LDT vs. SCT) independently predicted survival (P < 0.05). The clinical efficacy congruously favored the SCT-LDT group across the majority of subgroups. CONCLUSIONS SCT combined with LDT was well tolerated and may be effective to improve survival of patients with PACLM. Ascites and large primary tumor size were poor prognostic factors associated with survival.
Collapse
Affiliation(s)
- Huaqiang Ouyang
- Department of Integrative Oncology, Tianjin Medical University Cancer Institute and Hospital, Tianjin, China; National Clinical Research Center for Cancer, Key Laboratory of Cancer Prevention and Therapy, Tianjin, Tianjin's Clinical Research Center for Cancer, Tianjin, China
| | - Weidong Ma
- National Clinical Research Center for Cancer, Key Laboratory of Cancer Prevention and Therapy, Tianjin, Tianjin's Clinical Research Center for Cancer, Tianjin, China; Department of Pancreatic Oncology, Tianjin Medical University Cancer Institute and Hospital, Tianjin, China
| | - Ti Zhang
- National Clinical Research Center for Cancer, Key Laboratory of Cancer Prevention and Therapy, Tianjin, Tianjin's Clinical Research Center for Cancer, Tianjin, China; Department of Hepatobiliary Surgery, Tianjin Medical University Cancer Institute and Hospital, Tianjin, China
| | - Fang Liu
- National Clinical Research Center for Cancer, Key Laboratory of Cancer Prevention and Therapy, Tianjin, Tianjin's Clinical Research Center for Cancer, Tianjin, China; Department of Interventional Oncology, Tianjin Medical University Cancer Institute and Hospital, Tianjin, China
| | - Lujun Zhao
- National Clinical Research Center for Cancer, Key Laboratory of Cancer Prevention and Therapy, Tianjin, Tianjin's Clinical Research Center for Cancer, Tianjin, China; Department of Radiation Oncology, Tianjin Medical University Cancer Institute and Hospital, Tianjin, China
| | - Minghui Fang
- Department of Integrative Oncology, Tianjin Medical University Cancer Institute and Hospital, Tianjin, China; National Clinical Research Center for Cancer, Key Laboratory of Cancer Prevention and Therapy, Tianjin, Tianjin's Clinical Research Center for Cancer, Tianjin, China
| | - Manman Quan
- Department of Integrative Oncology, Tianjin Medical University Cancer Institute and Hospital, Tianjin, China; National Clinical Research Center for Cancer, Key Laboratory of Cancer Prevention and Therapy, Tianjin, Tianjin's Clinical Research Center for Cancer, Tianjin, China
| | - Zhanyu Pan
- Department of Integrative Oncology, Tianjin Medical University Cancer Institute and Hospital, Tianjin, China; National Clinical Research Center for Cancer, Key Laboratory of Cancer Prevention and Therapy, Tianjin, Tianjin's Clinical Research Center for Cancer, Tianjin, China.
| |
Collapse
|
23
|
Khachane A, Philippou Y, Hirst A, McCulloch P. Appraising the uptake and use of the IDEAL Framework and Recommendations: A review of the literature. Int J Surg 2018; 57:84-90. [PMID: 30098412 DOI: 10.1016/j.ijsu.2018.07.008] [Citation(s) in RCA: 24] [Impact Index Per Article: 3.4] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/06/2018] [Revised: 07/18/2018] [Accepted: 07/24/2018] [Indexed: 11/28/2022]
Abstract
INTRODUCTION Evaluation of new surgical innovations is complex and variably regulated, and historically the quality of surgical studies has been criticized. The IDEAL (Idea, Development, Exploration, Assessment, Long-term monitoring) Framework was established to provide a pathway for evaluating surgical innovations at each stage of their development in order to produce high quality surgical research. Since the inception of IDEAL in 2009, there has been no assessment of its use. In this review, we look at the uptake and usage of IDEAL by examining the published literature. METHODS We conducted a literature search to identify all of the publications that cited IDEAL and included only those papers that intentionally used IDEAL as part of the study methodology. We then characterized these publications by year of publication, specialty, and geographical location. We performed a critical appraisal of Stage 1, 2a, and 2b studies in order to assess the degree to which authors have correctly followed the Framework and Recommendations. RESULTS We found 790 citations of IDEAL publications, and after abstract and full-text screening, 38 prospective studies for a surgical innovation that used IDEAL remained. We saw an overall increase in the uptake of IDEAL, with a predominance in urology and origin in the United Kingdom. The critical appraisal showed that although authors identified their project as using IDEAL, they often failed to include key IDEAL characteristics; this was especially true for the features unique to IDEAL Stages 2a and 2b. CONCLUSION It is evident from the large number of studies citing IDEAL that the importance and challenges of reporting surgical research is well recognized among researchers. There is growing enthusiasm for using IDEAL but the current level of understanding of the Recommendations is low. Clearer and more comprehensive explanation of the application of the IDEAL Framework and Recommendations is needed to guide surgical researchers undertaking IDEAL based studies of surgical innovations.
Collapse
Affiliation(s)
- Asha Khachane
- IDEAL Collaboration, Oxford, UK, Maimonides Medical Center, Brooklyn, NY, USA.
| | | | | | | |
Collapse
|
24
|
Caloone J, Huissoud C, Kocot A, Vincenot J, Dehay C, Giroud P, Misery P, Allias F, Rudigoz RC, Melodelima D. Non-invasive high-intensity focused ultrasound treatment of the placenta: a preliminary in-vivo study using a simian model. ULTRASOUND IN OBSTETRICS & GYNECOLOGY : THE OFFICIAL JOURNAL OF THE INTERNATIONAL SOCIETY OF ULTRASOUND IN OBSTETRICS AND GYNECOLOGY 2017; 50:635-641. [PMID: 27804180 DOI: 10.1002/uog.17350] [Citation(s) in RCA: 11] [Impact Index Per Article: 1.4] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 06/05/2016] [Revised: 10/23/2016] [Accepted: 10/24/2016] [Indexed: 06/06/2023]
Abstract
OBJECTIVE To demonstrate the feasibility and efficacy of high-intensity focused ultrasound (HIFU) for the non-invasive creation of placental lesions in a simian model. METHODS Eight pregnant monkeys were exposed to HIFU treatment after anesthesia, using a toroidal HIFU 2.5-MHz transducer with an integrated ultrasound imaging probe. Lesions on the placental tissue were created non-invasively by placing the HIFU probe on the skin surface. Fetal and maternal parameters, such as maternal heart rate, fetal heart rate and subcutaneous and intra-amniotic fluid temperature, were recorded during HIFU exposure. Cesarean section was performed immediately after the procedure to extract the placenta and examine the fetus and the maternal abdominal cavity. Placental HIFU lesions were assessed by ultrasound, gross pathology and histology. RESULTS The mean gestational age of the monkeys was 72 ± 4 days. In total, 13 HIFU procedures were performed. The acoustic power and exposure time were increased progressively. This gradual increase in total energy delivered was used to determine a set of parameters to create reproducible lesions in the placenta without complications. Five placental lesions were observed with average diameters of 6.4 ± 0.5 mm and 7.8 ± 0.7 mm and an average depth of 3.8 ± 1.5 mm. Ultrasound examination of the placentae revealed hyperechoic regions that correlated well with macroscopic analysis of the HIFU lesions. Necrosis of placental tissue exposed to HIFU was confirmed with macroscopic and microscopic analysis. There was no significant variation in maternal and fetal parameters during HIFU exposure. CONCLUSIONS This study demonstrates the feasibility of HIFU applied non-invasively to the placental unit in an in-vivo pregnant monkey model. The technique is safe in the immediate short term and is potentially translatable to human pregnancy. Copyright © 2016 ISUOG. Published by John Wiley & Sons Ltd.
Collapse
Affiliation(s)
- J Caloone
- Inserm, U1032, Laboratory of Therapeutic Applications of Ultrasound, Lyon, France
- Université de Lyon, Lyon, France
- Department of Obstetrics and Gynecology, Croix Rousse University Hospital, Lyon, France
| | - C Huissoud
- Department of Obstetrics and Gynecology, Croix Rousse University Hospital, Lyon, France
- Stem Cell and Brain Research Institute, Institut National de la Sante et de la Recherche Médicale U846, Bron, France
| | - A Kocot
- Inserm, U1032, Laboratory of Therapeutic Applications of Ultrasound, Lyon, France
- Université de Lyon, Lyon, France
| | - J Vincenot
- Inserm, U1032, Laboratory of Therapeutic Applications of Ultrasound, Lyon, France
- Université de Lyon, Lyon, France
| | - C Dehay
- Stem Cell and Brain Research Institute, Institut National de la Sante et de la Recherche Médicale U846, Bron, France
| | - P Giroud
- Stem Cell and Brain Research Institute, Institut National de la Sante et de la Recherche Médicale U846, Bron, France
| | - P Misery
- Stem Cell and Brain Research Institute, Institut National de la Sante et de la Recherche Médicale U846, Bron, France
| | - F Allias
- Université de Lyon, Lyon, France
- Department of Pathology, Croix Rousse University Hospital, Lyon, France
| | - R C Rudigoz
- Department of Obstetrics and Gynecology, Croix Rousse University Hospital, Lyon, France
| | - D Melodelima
- Inserm, U1032, Laboratory of Therapeutic Applications of Ultrasound, Lyon, France
- Université de Lyon, Lyon, France
| |
Collapse
|
25
|
N'Djin WA, Gerold B, Vion-Bailly J, Canney MS, Nguyen-Dinh A, Carpentier A, Chapelon JY. Capacitive Micromachined Ultrasound Transducers for Interstitial High-Intensity Ultrasound Therapies. IEEE TRANSACTIONS ON ULTRASONICS, FERROELECTRICS, AND FREQUENCY CONTROL 2017; 64:1245-1260. [PMID: 28541897 DOI: 10.1109/tuffc.2017.2707663] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/07/2023]
Abstract
Capacitive micromachined ultrasound transducers (CMUTs) exhibit several potential advantages over conventional piezo technologies for use in therapeutic ultrasound (US) devices, including ease of miniaturization and integration with electronics, broad bandwidth (>several megahertz), and compatibility with magnetic resonance imaging (MRI). In this paper, the electroacoustic performance of CMUTs designed for interstitial high-intensity contact US (HICU) applications was evaluated and the feasibility of generating US-induced heating and thermal destruction of biological tissues was studied. One-dimensional CMUT linear arrays as well as a prism-shaped 2-D array composed of multiple 1-D linear arrays mounted on a cylindrical catheter were fabricated. The electromechanical and acoustic characteristics of the CMUTs were first studied at low intensity. Then, the acoustic output during continuous wave (CW) driving was studied while varying the bias voltage ( VDC ) and driving voltage ( VAC ). US heating was performed in tissue-mimicking gel phantoms under infrared (IR) or MR-thermometry monitoring. Acoustic intensities compatible with thermal ablation were obtained by driving the CMUTs in the collapse-snapback operation mode ( [Formula: see text]). Hysteresis in the acoustic output was observed with varying VDC . IR- and MR-thermometry monitoring showed directional US-induced heating patterns in tissue-mimicking phantoms (frequency: 6-8 MHz and exposure time: 60-240 s) extending over 1.5-cm depth from the CMUT surface. Irreversible thermal damage was produced in turkey breast tissue samples ( [Formula: see text]). Multidirectional US-induced heating was also achieved in 3-D with the CMUT catheter. These studies demonstrate that CMUTs can be integrated into HICU devices and be used for heating and destruction of tissue under MR guidance.
Collapse
|
26
|
Dupré A, Pérol D, Blanc E, Peyrat P, Basso V, Chen Y, Vincenot J, Kocot A, Melodelima D, Rivoire M. Efficacy of high-intensity focused ultrasound-assisted hepatic resection (HIFU-AR) on blood loss reduction in patients with liver metastases requiring hepatectomy: study protocol for a randomized controlled trial. Trials 2017; 18:57. [PMID: 28166812 PMCID: PMC5294714 DOI: 10.1186/s13063-017-1801-2] [Citation(s) in RCA: 6] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/19/2016] [Accepted: 01/16/2017] [Indexed: 01/26/2023] Open
Abstract
BACKGROUND Liver resection is the only potentially curative treatment for colorectal liver metastases (LM). It is considered a safe procedure, but is often associated with blood loss during liver transection. Blood transfusions are frequently needed, but they are associated with increased morbidity and risk of recurrence. Many surgical devices have been developed to decrease blood loss. However, none of them has proven superior to the standard crushing technique. We developed a new, powerful intra-operative high-intensity focused ultrasound (HIFU) transducer which destroys tissue by coagulative necrosis. We aim to evaluate whether HIFU-assisted liver resection (HIFU-AR) results in reduced blood loss. METHODS This is a prospective, single-centre, randomized (1:1 ratio), comparative, open-label phase II study. Patients with LM requiring a hepatectomy for ≥ 2 segments will be included. Patients with cirrhosis or sinusoidal obstruction syndrome with portal hypertension will be excluded. The primary endpoint is normalized blood loss in millilitres per square centimetre of liver section plane. Secondary endpoints are: total blood loss, transection time, transection time per square centimetre of liver area, haemostasis time, clip density on the liver section area, rate and duration of the Pringle manœuvre, rate of patients needing a blood transfusion, length of hospital stay, morbidity, patients with positive resection margin, and local recurrence. Assuming a blood loss of 7.6 ± 3.7 mL/cm2 among controls, the study will have 85% power to detect a twofold decrease of blood loss in the experimental arm, using a Wilcoxon (Mann-Whitney) rank-sum test with a 0.05 two-sided significance level. Twenty-one randomized patients per arm are required. Considering the risk of contraindications at surgery, up to eight patients may be enrolled in addition to the 42 planned, with an enrolment period of 24 months. Randomization will be stratified by surgeon. DISCUSSION We previously demonstrated the safety and efficacy of intra-operative HIFU in patients operated on for LM. We also demonstrated the efficacy of HIFU-AR in a preclinical study. Participants in the HIFU-AR group of this randomized trial can expect to benefit from reduced blood loss and decreased ischemia of liver parenchyma. TRIAL REGISTRATION Clinicaltrial.gov, NCT02728167 . Registered on 22 March 2016.
Collapse
Affiliation(s)
- Aurélien Dupré
- Department of Surgical Oncology, Centre Léon Bérard, 28 Rue Laennec, Lyon, 69008, France. .,Inserm, U1032, LabTau, University of Lyon, Lyon, 69003, France.
| | - David Pérol
- Department of Clinical Research (DRCI), Centre Léon Bérard, Lyon, 69008, France
| | - Ellen Blanc
- Department of Clinical Research (DRCI), Centre Léon Bérard, Lyon, 69008, France
| | - Patrice Peyrat
- Department of Surgical Oncology, Centre Léon Bérard, 28 Rue Laennec, Lyon, 69008, France
| | - Valéria Basso
- Department of Surgical Oncology, Centre Léon Bérard, 28 Rue Laennec, Lyon, 69008, France
| | - Yao Chen
- Department of Surgical Oncology, Centre Léon Bérard, 28 Rue Laennec, Lyon, 69008, France
| | - Jérémy Vincenot
- Inserm, U1032, LabTau, University of Lyon, Lyon, 69003, France
| | - Anthony Kocot
- Inserm, U1032, LabTau, University of Lyon, Lyon, 69003, France
| | | | - Michel Rivoire
- Department of Surgical Oncology, Centre Léon Bérard, 28 Rue Laennec, Lyon, 69008, France.,Inserm, U1032, LabTau, University of Lyon, Lyon, 69003, France
| |
Collapse
|
27
|
Thermal Ablation of the Pancreas With Intraoperative High-Intensity Focused Ultrasound: Safety and Efficacy in a Porcine Model. Pancreas 2017; 46:219-224. [PMID: 27841792 DOI: 10.1097/mpa.0000000000000720] [Citation(s) in RCA: 15] [Impact Index Per Article: 1.9] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 01/05/2023]
Abstract
OBJECTIVE New focal destruction technologies such as high-intensity focused ultrasound (HIFU) may improve the prognosis of pancreatic ductal adenocarcinoma. Our objectives were to demonstrate the safety and efficacy of intraoperative pancreatic HIFU ablation in a porcine model. METHODS In a porcine model (N = 12), a single HIFU ablation was performed in either the body or tail of the pancreas, distant to superior mesenteric vessels. All animals were sacrificed on the eighth day. The primary objective was to obtain an HIFU ablation measuring at least 1 cm without premature death. RESULTS In total, 12 HIFU ablations were carried out. These ablations were performed within 160 seconds and on average measured 20 (15-27) × 16 (8-26) mm. The primary objective was fulfilled in all but 1 pig. There were no premature deaths or severe complications. High-intensity focused ultrasound treatment was associated with a transitory increase in amylase and lipase levels, and pseudocysts were observed in half of the pigs without being clinically apparent. All ablations were well delimited at both gross and histological examinations. CONCLUSIONS Intraoperative thermal destruction of porcine pancreas with HIFU is feasible. Reproducibility and safety have to be confirmed when applied close to mesenteric vessels and in long-term preclinical studies.
Collapse
|
28
|
Lesser TG, Boltze C, Schubert H, Wolfram F. Flooded Lung Generates a Suitable Acoustic Pathway for Transthoracic Application of High Intensity Focused Ultrasound in Liver. Int J Med Sci 2016; 13:741-748. [PMID: 27766022 PMCID: PMC5069408 DOI: 10.7150/ijms.16411] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 06/07/2016] [Accepted: 08/22/2016] [Indexed: 01/20/2023] Open
Abstract
Background: In recent years, high intensity focused ultrasound (HIFU) has gained increasing clinical interest as a non-invasive method for local therapy of liver malignancies. HIFU treatment of tumours and metastases in the liver dome is limited due to the adjacent ultrasound blocking lung. One-lung flooding (OLF) enables complete sonography of lung and adjoining organs including liver. HIFU liver ablation passing through the flooded lung could enable a direct intercostal beam path and thus improve dose deposition in liver. In this study, we evaluate the feasibility of an ultrasound guided transthoracic, transpulmonary HIFU ablation of liver using OLF. Methods: After right-side lung flooding, ultrasound guided HIFU was applied transthoracic- transpulmonary into liver to create thermal lesions in three pigs. The HIFU beam was targeted five times into liver, two times at the liver surface and three times deeper into the tissue. During autopsy examinations of lung, diaphragm and liver located in the HIFU path were performed. The focal liver lesions and lung tissue out of the beam path were examined histologically. Results: Fifteen thermal liver lesions were generated by transpulmonary HIFU sonication in all targeted regions. The lesions appeared well-demarcated in grey color with a cigar-shaped configuration. The mean length and width of the superficial and deeper lesions were 15.8 mm (range: 13-18 mm) and 5.8 mm (range: 5-7 mm), and 10.9 mm (range: 9-13 mm) and 3.3 mm (range: 2-5 mm), respectively. Histopathological, all liver lesions revealed a homogeneous thermal necrosis lacking vitality. There were no signs of damage of the overlying diaphragm and lung tissue. Conclusions: Flooded lung is a suitable pathway for applying HIFU to the liver, thus enabling a transthoracic, transpulmonary approach. The enlarged acoustic window could enhance the ablation speed for targets in the hepatic dome.
Collapse
Affiliation(s)
- Thomas Günther Lesser
- Department of Thoracic and Vascular Surgery, SRH Wald-Klinikum Gera, Teaching Hospital of Friedrich-Schiller University of Jena, Germany
| | - Carsten Boltze
- Institute of Pathology, SRH Wald-Klinikum Gera, Teaching Hospital of Friedrich-Schiller University Jena, Germany
| | - Harald Schubert
- Institute of Animal Experimentation and Animal Welfare, Jena University Hospital, Friedrich-Schiller University Jena, Germany
| | - Frank Wolfram
- Department of Thoracic and Vascular Surgery, SRH Wald-Klinikum Gera, Teaching Hospital of Friedrich-Schiller University of Jena, Germany
| |
Collapse
|
29
|
Bessiere F, N'djin WA, Colas EC, Chavrier F, Greillier P, Chapelon JY, Chevalier P, Lafon C. Ultrasound-Guided Transesophageal High-Intensity Focused Ultrasound Cardiac Ablation in a Beating Heart: A Pilot Feasibility Study in Pigs. ULTRASOUND IN MEDICINE & BIOLOGY 2016; 42:1848-1861. [PMID: 27158083 DOI: 10.1016/j.ultrasmedbio.2016.03.007] [Citation(s) in RCA: 17] [Impact Index Per Article: 1.9] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 06/09/2015] [Revised: 03/02/2016] [Accepted: 03/11/2016] [Indexed: 06/05/2023]
Abstract
Catheter ablation for the treatment of arrhythmia is associated with significant complications and often-repeated procedures. Consequently, a less invasive and more efficient technique is required. Because high-intensity focused ultrasound (HIFU) enables the generation of precise thermal ablations in deep-seated tissues without harming the tissues in the propagation path, it has the potential to be used as a new ablation technique. A system capable of delivering HIFU into the heart by a transesophageal route using ultrasound (US) imaging guidance was developed and tested in vivo in six male pigs. HIFU exposures were performed on atria and ventricles. At the time of autopsy, visual inspection identified thermal lesions in the targeted areas in three of the animals. These lesions were confirmed by histologic analysis (mean size: 5.5 mm(2) × 11 mm(2)). No esophageal thermal injury was observed. One animal presented with bradycardia due to an atrio-ventricular block, which provides real-time confirmation of an interaction between HIFU and the electrical circuits of the heart. Thus, US-guided HIFU has the potential to minimally invasively create myocardial lesions without an intra-cardiac device.
Collapse
Affiliation(s)
- Francis Bessiere
- Hospices Civils de Lyon, Hôpital Cardiovasculaire Louis Pradel, Lyon, France; Inserm, LabTau, Lyon, France; Université de Lyon, Lyon, France.
| | | | | | | | - Paul Greillier
- Hospices Civils de Lyon, Hôpital Cardiovasculaire Louis Pradel, Lyon, France; Inserm, LabTau, Lyon, France
| | | | - Philippe Chevalier
- Hospices Civils de Lyon, Hôpital Cardiovasculaire Louis Pradel, Lyon, France; Université de Lyon, Lyon, France
| | - Cyril Lafon
- Inserm, LabTau, Lyon, France; Université de Lyon, Lyon, France
| |
Collapse
|
30
|
Vincenot J, Kocot A, Vignot A, Chavrier F, Blanc E, Dupré A, Rivoire M, Chapelon J, Melodelima D. Toroidal Transducer for Intraoperative Thermal Ablation of Pancreatic Tumours by High-Intensity Focused Ultrasound. First In Vitro Experiments. Ing Rech Biomed 2016. [DOI: 10.1016/j.irbm.2016.02.001] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/22/2022]
|
31
|
Abstract
High intensity focused ultrasound (HIFU) is rapidly gaining clinical acceptance as a technique capable of providing non-invasive heating and ablation for a wide range of applications. Usually requiring only a single session, treatments are often conducted as day case procedures, with the patient either fully conscious, lightly sedated or under light general anesthesia. HIFU scores over other thermal ablation techniques because of the lack of necessity for the transcutaneous insertion of probes into the target tissue. Sources placed either outside the body (for treatment of tumors or abnormalities of the liver, kidney, breast, uterus, pancreas brain and bone), or in the rectum (for treatment of the prostate), provide rapid heating of a target tissue volume, the highly focused nature of the field leaving tissue in the ultrasound propagation path relatively unaffected. Numerous extra-corporeal, transrectal and interstitial devices have been designed to optimize application-specific treatment delivery for the wide-ranging areas of application that are now being explored with HIFU. Their principle of operation is described here, and an overview of their design principles is given.
Collapse
Affiliation(s)
- Gail Ter Haar
- Joint Department of Physics, The Institute of Cancer Research, Sutton, London, UK.
| |
Collapse
|
32
|
An Ultrasound Image-Based Dynamic Fusion Modeling Method for Predicting the Quantitative Impact of In Vivo Liver Motion on Intraoperative HIFU Therapies: Investigations in a Porcine Model. PLoS One 2015; 10:e0137317. [PMID: 26398366 PMCID: PMC4580572 DOI: 10.1371/journal.pone.0137317] [Citation(s) in RCA: 13] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/06/2015] [Accepted: 08/15/2015] [Indexed: 11/19/2022] Open
Abstract
Organ motion is a key component in the treatment of abdominal tumors by High Intensity Focused Ultrasound (HIFU), since it may influence the safety, efficacy and treatment time. Here we report the development in a porcine model of an Ultrasound (US) image-based dynamic fusion modeling method for predicting the effect of in vivo motion on intraoperative HIFU treatments performed in the liver in conjunction with surgery. A speckle tracking method was used on US images to quantify in vivo liver motions occurring intraoperatively during breathing and apnea. A fusion modeling of HIFU treatments was implemented by merging dynamic in vivo motion data in a numerical modeling of HIFU treatments. Two HIFU strategies were studied: a spherical focusing delivering 49 juxtapositions of 5-second HIFU exposures and a toroidal focusing using 1 single 40-second HIFU exposure. Liver motions during breathing were spatially homogenous and could be approximated to a rigid motion mainly encountered in the cranial-caudal direction (f = 0.20 Hz, magnitude > 13 mm). Elastic liver motions due to cardiovascular activity, although negligible, were detectable near millimeter-wide sus-hepatic veins (f = 0.96 Hz, magnitude < 1 mm). The fusion modeling quantified the deleterious effects of respiratory motions on the size and homogeneity of a standard "cigar-shaped" millimetric lesion usually predicted after a 5-second single spherical HIFU exposure in stationary tissues (Dice Similarity Coefficient: DSC < 45%). This method assessed the ability to enlarge HIFU ablations during respiration, either by juxtaposing "cigar-shaped" lesions with spherical HIFU exposures, or by generating one large single lesion with toroidal HIFU exposures (DSC > 75%). Fusion modeling predictions were preliminarily validated in vivo and showed the potential of using a long-duration toroidal HIFU exposure to accelerate the ablation process during breathing (from 0.5 to 6 cm3 · min(-1)). To improve HIFU treatment control, dynamic fusion modeling may be interesting for assessing numerically focusing strategies and motion compensation techniques in more realistic conditions.
Collapse
|
33
|
Correction: First clinical experience of intra-operative high intensity focused ultrasound in patients with colorectal liver metastases: a phase I-IIa study. PLoS One 2015; 10:e0123751. [PMID: 25822493 PMCID: PMC4378928 DOI: 10.1371/journal.pone.0123751] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Download PDF] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/23/2022] Open
|