1
|
Wu YF, Tu RX, Zhang Y, Zhao XY, Qu J, Wang Y, Yu AY. Influence of Ocular Biometric Parameters on Intraocular Lens Position: A Prospective Cohort Study. J Refract Surg 2024; 40:e438-e444. [PMID: 39007810 DOI: 10.3928/1081597x-20240514-02] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 07/16/2024]
Abstract
PURPOSE To assess the influence of ocular biometric parameters on intraocular lens (IOL) tilt and decentration after cataract surgery. METHODS Patients scheduled for cataract surgery were screened for inclusion in this prospective cohort study. Tilt and decentration of the crystalline lens and IOL were measured using the CASIA2 (Tomey). Anterior chamber depth (ACD), lens thickness (LT), and axial length (AL) were preoperatively measured by the IOLMaster 700 (Carl Zeiss Meditec AG). Multivariate regression analysis was performed to assess the influence of ocular biometric parameters on IOL tilt and decentration after cataract surgery. RESULTS In total, 191 eyes of 120 patients were included. Age was positively correlated with IOL tilt, whereas ACD and AL were negatively correlated with IOL tilt. A strong positive correlation was found between preoperative crystalline lenses and postoperative IOLs in tilt magnitude (r = 0.769, P < .001) and tilt direction (r = 0.688, P < .001). A positive correlation was found between preoperative and postoperative lens decentration magnitude and decentration direction. Greater postoperative IOL tilt and decentration were significantly associated with greater preoperative crystalline lens tilt (P < .001) and decentration (P = .027). CONCLUSIONS IOL tilt was greater in older patients. Shorter AL and shallower ACD contributed to greater IOL tilt. The tilt and decentration of the IOL will be greater in patients with greater tilt and decentration of the crystalline lens. [J Refract Surg. 2024;40(7):e438-e444.].
Collapse
|
2
|
de Paula A, Gattazzo I, Savini G, Schiano Lomoriello D, Corsi A. An analysis of the factors involved in IOL decentration after phacoemulsification using CASIA 2 anterior segment optical coherence tomography. Int Ophthalmol 2024; 44:194. [PMID: 38656707 DOI: 10.1007/s10792-024-03126-5] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/21/2024] [Accepted: 04/11/2024] [Indexed: 04/26/2024]
Abstract
PURPOSE To evaluate the magnitude of IOL transversal shift (ITS) after phacoemulsification and to analyse the factors contributing to IOL decentration and ITS. METHODS 94 consecutive patients who underwent cataract surgery and IOL implantation was enrolled. Each patient underwent anterior segment optical coherence tomography with CASIA 2 (Tomey, Nagoya, Japan) to assess crystalline lens decentration, thickness and diameter seven days preoperatively and at one and sixty days postoperatively. Univariate and multivariate linear regression analysis were performed to evaluate the determinants of ITS and final decentration. RESULTS The preoperative crystalline lens diameter was associated with the ITS and with the IOL final decentration. A positive association between the final IOL decentration and the first post-surgical day decentration was found (p < 0.0001). CONCLUSION Greater crystalline lens diameter was associated with greater decentration and with greater ITS. Day-one IOL decentration seems to be the main determinant of final IOL decentration.
Collapse
Affiliation(s)
- Alessandro de Paula
- Ophthalmology Unit, Policlinico Casilino, Via Casilina, 1049, 00169, Rome, Italy.
| | - Irene Gattazzo
- Ophthalmology Unit, NESMOS Department, St. Andrea Hospital, University of Rome "La Sapienza", Rome, Italy
| | | | | | - Andrea Corsi
- Ophthalmology Unit, Policlinico Casilino, Via Casilina, 1049, 00169, Rome, Italy
| |
Collapse
|
3
|
Liu X, Wu W, Huang Y, Fu Y, Huang Y, Li Q. Repeatability of Pentacam-derived intraocular lens decentration measurements and the level of agreement with OPD-Scan III: A prospective observational case series. PLoS One 2024; 19:e0299064. [PMID: 38517869 PMCID: PMC10959365 DOI: 10.1371/journal.pone.0299064] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/05/2023] [Accepted: 01/03/2024] [Indexed: 03/24/2024] Open
Abstract
PURPOSE This study aimed to assess the repeatability of intraocular lens (IOL) decentration measurements obtained through Pentacam, based on corneal topographic axis (CTA) and pupillary axis (PA), and to evaluate the level of agreement between Pentacam and OPD-Scan III devices in measuring IOL decentration. METHODS In this prospective observational case series, three measurements were performed with Pentacam to evaluate the repeatability of the measurements. The analysis included the calculation of the mean and standard deviations (SD), conducting a repeated measures analysis of variance (rANOVA), and determining an intraclass correlation coefficient (ICC) to assess the repeatability of the measurements. Moreover, Bland-Altman analysis was employed to assess the agreement between Pentacam and OPD-Scan III devices in measuring IOL decentration. IOL decentration measurements were obtained with respect to both CTA and PA. RESULTS A total of 40 eyes from 40 patients were analyzed. The rANOVA revealed no significant difference among three consecutive measurements of IOL decentration obtained with Pentacam. The mean SD of all parameters ranged from 0.04 mm to 0.07 mm. With CTA as the reference axis, the ICC values for Pentacam measurements of IOL decentration were 0.82 mm for the X-axis, 0.76 mm for the Y-axis, and 0.82 mm for spatial distance. When using PA as the reference axis, the corresponding ICC values were 0.87, 0.89, and 0.77, respectively. The 95% limits of agreement for all IOL decentration measurements were wide when comparing Pentacam and OPD-Scan III. CONCLUSIONS Pentacam demonstrated high repeatability in measuring IOL decentration with respect to both CTA and PA. However, due to poor agreement between Pentacam and OPD-Scan III measurements, caution should be exercised when using data interchangeably between the two devices.
Collapse
Affiliation(s)
- Xiaobao Liu
- Shengli Clinical Medical College of Fujian Medical University; Fujian Medical University, Fuzhou, China
| | - Wenjie Wu
- Shengli Clinical Medical College of Fujian Medical University; Fujian Medical University, Fuzhou, China
- Department of Ophthalmology, Fujian Provincial Hospital, Fuzhou, China
| | - Yulong Huang
- Shengli Clinical Medical College of Fujian Medical University; Fujian Medical University, Fuzhou, China
| | - Yabo Fu
- Shengli Clinical Medical College of Fujian Medical University; Fujian Medical University, Fuzhou, China
- Department of Ophthalmology, Longyan People Hospital of Fujian, Longyan, China
| | - Yue Huang
- Shengli Clinical Medical College of Fujian Medical University; Fujian Medical University, Fuzhou, China
| | - Qiong Li
- Shengli Clinical Medical College of Fujian Medical University; Fujian Medical University, Fuzhou, China
- Department of Ophthalmology, Fujian Provincial Hospital, Fuzhou, China
| |
Collapse
|
4
|
Armonaite L, Behndig A. Repositioning of in-the-bag Dislocated Intraocular Lenses: A Randomized Clinical Trial Comparing Two Surgical Methods. Ophthalmic Res 2023; 66:590-598. [PMID: 36739865 DOI: 10.1159/000529506] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/04/2022] [Accepted: 01/27/2023] [Indexed: 02/05/2023]
Abstract
INTRODUCTION The aim of this study was to evaluate intraocular lens (IOL) tilt, IOL-induced astigmatism (IIA), refractive change, and impact of capsular fibrosis on IOL position after scleral fixation of dislocated IOL using two methods: ab externo scleral suture loop fixation (group A) and a modification, embracing the continuous curvilinear capsulorhexis (group B). METHODS In this prospective randomized clinical trial conducted at St. Erik Eye Hospital, 117 patients with dislocated IOL were randomized to group A (n = 61) or B (n = 56). Patients with ordinary pseudophakia (n = 60) served as controls. IOL tilt was measured three-dimensionally with anterior segment optical coherence tomography (AS-OCT). RESULTS The median IOL tilt was similar with both methods (A: 7.8°; B: 8.3°; p = 0.51) but higher than in ordinary pseudophakia (5.4°; p < 0.001). Both groups showed a myopic shift, p < 0.001. In cases without capsular fibrosis, the median IOL tilt was 15.5° in group A (n = 7) and 7.0° in group B (n = 5), p = 0.19. For each degree of IOL tilt, IIA increased by 0.075 D (p < 0.001). IOL position could be measured with AS-OCT in all patients given that the IOL was visible in the pupil. CONCLUSION After IOL fixation surgery, IOL tilt is higher than in normal pseudophakia. A study involving more patients without capsular fibrosis could clarify whether IOL position is better with method B in this subgroup. IAA is low, but myopic shift is common. AS-OCT is useful for IOL tilt assessment after IOL fixation surgery.
Collapse
Affiliation(s)
- Laura Armonaite
- Division of Ophthalmology and Vision, Department of Clinical Neuroscience, St. Erik Eye Hospital, Karolinska Institutet, Stockholm, Sweden
| | - Anders Behndig
- Department of Clinical Sciences/Ophthalmology, Umeå University Hospital, Umeå University, Umeå, Sweden
| |
Collapse
|
5
|
Osawa R, Sano M, Yuguchi T, Kaiya T, Oshika T. Effects of Modified Haptics on Surgical Outcomes and Rotational Stability of Toric Intraocular Lens Implantation. J Refract Surg 2022; 38:648-653. [PMID: 36214346 DOI: 10.3928/1081597x-20220715-02] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/05/2022]
Abstract
PURPOSE To assess the rotational stability of a new toric intraocular lens (IOL), TECNIS toric II (toric II), which is a modified version of the TECNIS toric IOL (toric I) with frosted haptics (Johnson & Johnson). METHODS A total of 101 eyes of 101 patients who had been treated with phacoemulsification and toric IOL implantation were included. Before and 1 day, 1 week, and 1 month after surgery, uncorrected (UDVA) and corrected (CDVA) distance visual acuity were measured. Preoperative corneal astigmatism and postoperative manifest refractive astigmatism at 1 day and 1 month were analyzed. At 1 day and 1 month postoperatively, the amount of IOL axis misalignment from the intended orientation, tilt, and decentration were measured using anterior segment optical coherence tomography. RESULTS Fifty-one eyes received the toric I IOL and 50 eyes received the toric II IOL. Toric I IOLs showed a significantly larger amount of axis misalignment than toric II IOLs at both 1 day (9.6 ± 7.6° vs 5.4 ± 4.8°, P = .003) and 1 month (9.1 ± 7.8° vs. 4.7 ± 4.2°, P = .003) postoperatively.The proportion of eyes with misalignment greater than 10° was significantly larger with toric I than toric II IOLs (P < .001). There were no significant differences between IOLs in the amount of residual astigmatism, UDVA, CDVA, and amount of tilt and decentration at 1 day and 1 month postoperatively. CONCLUSIONS The TECNIS toric II IOL with frosted haptics has significantly improved rotational stability compared to its previous model. [J Refract Surg. 2022;38(10):648-653.].
Collapse
|
6
|
Tokuhisa T, Watanabe T, Watanabe A, Nakano T. Refractive error induced by intraocular lens tilt after intrascleral intraocular lens fixation. Int Ophthalmol 2022; 42:1213-1220. [PMID: 35064856 DOI: 10.1007/s10792-021-02106-3] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/31/2021] [Accepted: 10/21/2021] [Indexed: 10/19/2022]
Abstract
PURPOSE To investigate the spherical shift of intraocular lens (IOL) tilt after intrascleral fixation. METHODS We retrospectively reviewed the medical records of patients who underwent flanged intrascleral IOL fixation with transconjunctival 25- or 27-gauge pars plana vitrectomy at the Department of Ophthalmology of the Jikei University Hospital. The minimum follow-up duration was 3 months. Second-generation anterior segment optical coherence tomography (CASIA2; TOMEY) was used to obtain the values of tilt and decentration of the intrasclerally fixated IOL and postoperative anterior chamber depth. We investigated the relationship between refractive error and various parameters, such as IOL tilt and decentration, axial length, and keratometry. In addition to our clinical investigation, we conducted optical simulations using Zemax to evaluate the spherical shift of the IOL tilt by means of the through-focus response and change in spherical equivalent power. RESULTS The study involved 72 eyes of 67 patients. The degree of IOL tilt was correlated with the amount of refractive error (Spearman's rank correlation coefficient [CC] = - 0.32; P = 0.006). In particular, a tilt angle greater than 10° strongly affected the refractive error. The postoperative anterior chamber depth also correlated with the refractive error (CC = 0.50; P < 0.001), as opposed to decentration (CC = - 0.17; P = 0.15), axial length (CC = - 0.08; P = 0.49), and keratometry (CC = - 0.06; P = 0.64). Optical simulations also revealed a myopic shift that exponentially increased as the tilt became greater. CONCLUSION IOL tilts that are greater than 10° induce refractive error.
Collapse
Affiliation(s)
- Teruaki Tokuhisa
- Department of Ophthalmology, The Jikei University School of Medicine, 3-25-8 Nishishinbashi, Minatoku, Tokyo, 105-0003, Japan.
| | - Tomoyuki Watanabe
- Department of Ophthalmology, The Jikei University School of Medicine, 3-25-8 Nishishinbashi, Minatoku, Tokyo, 105-0003, Japan
| | - Akira Watanabe
- Department of Ophthalmology, The Jikei University School of Medicine, 3-25-8 Nishishinbashi, Minatoku, Tokyo, 105-0003, Japan
| | - Tadashi Nakano
- Department of Ophthalmology, The Jikei University School of Medicine, 3-25-8 Nishishinbashi, Minatoku, Tokyo, 105-0003, Japan
| |
Collapse
|
7
|
Adjustment of intraocular lens tilt during intrascleral fixation assisted by intraoperative OCT. J Cataract Refract Surg 2021; 47:1308-1313. [PMID: 34544086 DOI: 10.1097/j.jcrs.0000000000000615] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/30/2020] [Accepted: 02/04/2021] [Indexed: 01/19/2023]
Abstract
PURPOSE To evaluate the efficacy of using intraoperative optical coherence tomography (iOCT) to adjust the tilting of an intraocular lens (IOL) during implantation with intrascleral fixation. SETTING Kyorin University Hospital, Tokyo, Japan. DESIGN Retrospective, case-control, single-center study. METHODS Thirty-seven eyes of 37 patients who had undergone pars plana vitrectomy with intrascleral fixation of an IOL by a single surgeon were retrospectively studied. The length of the externalized haptics was determined when the anterior surface of the IOL was parallel to the plane of the iris as observed by iOCT. The maximal IOL tilt relative to the visual axis and to the iris plane was measured by anterior segment OCT (CASIA2; Tomey Corp.). RESULTS Intraoperative crosssectional OCT (RESCAN 700: Carl Zeiss Meditec AG) scans were used to adjust the degree of IOL tilt in 23 eyes (iOCT group) and not used in 14 eyes (control group). The maximal angle of IOL tilt relative to the visual axis was significantly smaller in the iOCT group than that in the control group (5.45 ± 2.63 degrees vs 10.38 ± 10.48 degrees, P = .034). The maximal angle of the IOL tilt to the iris plane was also significantly smaller in the iOCT group than that in the control group (4.58 ± 1.86 degrees vs 9.60 ± 10.82 degrees; P = .040). The distance of decentration was greater in the iOCT group (0.56 ± 0.29 mm) than that of the control group (0.41 ± 0.41 mm, P = .005). CONCLUSIONS Intraoperative OCT can be used to adjust the degree of IOL tilt to reduce the lenticular astigmatism during intrascleral fixation surgery.
Collapse
|
8
|
Influence of frosted haptics on rotational stability of toric intraocular lenses. Sci Rep 2021; 11:15099. [PMID: 34302005 PMCID: PMC8302686 DOI: 10.1038/s41598-021-94293-3] [Citation(s) in RCA: 17] [Impact Index Per Article: 5.7] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/24/2021] [Accepted: 07/01/2021] [Indexed: 11/24/2022] Open
Abstract
We investigated the unfolding property and rotational stability of a new toric intraocular lens (IOL); TECNIS toric II (toric-II, ZCW, Johnson & Johnson) that is an improved version of TECNIS toric IOL (toric-I, ZCV). Both IOLs are based on an identical platform, except for the frosted haptics with toric-II IOL. The study consisted of two parts; experimental study and clinical, retrospective, case series. Experimental study indicated that the overall time from IOL ejection to unfolding to 11 mm was significantly shorter with toricII than toric-I IOLs (p = 0.032), due to the earlier separation of the haptics from the optic with toric-II IOL. Clinical study included 131 eyes of 99 patients who had undergone phacoemulsification and toric IOL implantation. At 3 months postoperatively, toric-II IOL showed significantly better rotational stability than toric-I IOL, including smaller residual manifest astigmatism (p = 0.018), less amount of axis misalignment from the intended axis (p = 0.04), lower incidence of misalignment > 10º (p = 0.0044), and less degree of prediction errors (p = 0.043). Postoperative uncorrected distance visual acuity tended to be better in the toric-II than in the toric-I groups, with marginal statistical difference (p = 0.057). TECNIS toric II IOL with the frosted haptics showed significantly better rotational stability than its predecessor, probably due to quicker unfolding and greater friction with the capsular bag.
Collapse
|
9
|
Ding X, Wang Q, Xiang L, Chang P, Huang S, Zhao YE. Three-Dimensional Assessments of Intraocular Lens Stability With High-Speed Swept-Source Optical Coherence Tomography. J Refract Surg 2021; 36:388-394. [PMID: 32521026 DOI: 10.3928/1081597x-20200420-01] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/09/2019] [Accepted: 04/20/2020] [Indexed: 12/28/2022]
Abstract
PURPOSE To evaluate the effect of intraocular lens (IOL) optic overlapping on IOL stability and to determine the relationship between the capsulorhexis and IOL movement with the three-dimensional method of swept-source optical coherence tomography (SS-OCT). METHODS This study identified patients with age-related cataracts and divided them into two groups according to their anterior capsule and IOL optic relationship: total anterior capsule overlap (360°) and partial anterior capsule overlap (< 360°). Standard SS-OCT radial scanning was performed in all eyes at 1 day, 1 week, 1 month, and 3 months after cataract surgery, respectively. The obtained photographs were used for the postoperative position measurements of capsulorhexis and IOL after three-dimensional reconstruction. RESULTS This study included 46 eyes of 34 patients: total overlap group (n = 29) and partial overlap group (n = 17). The postoperative aqueous depth significantly decreased in the first week after surgery (P < .001). The IOL tilt was greater in the partial overlap group than that in the total overlap group (P = .014). The IOL moved significantly in the first week postoperatively (both P < .001). IOL decentration in the x-axis was greater in the partial overlap group than that in the total overlap group (P = .024). The IOL and capsulorhexis both moved sharply in the first week (both P < .05). The IOL moved consistently with the capsulorhexis in the 3 months after surgery (all P > .05). CONCLUSIONS The total overlap group showed better IOL centrality and stability. IOL movement may be driven by capsular bag contraction and fibrosis. Thus, it was demonstrated that postoperative IOL position and IOL performance were closely linked with proper size of central continuous curvilinear capsulorhexis. [J Refract Surg. 2020;36(6):388-394.].
Collapse
|
10
|
Ashena Z, Maqsood S, Ahmed SN, Nanavaty MA. Effect of Intraocular Lens Tilt and Decentration on Visual Acuity, Dysphotopsia and Wavefront Aberrations. Vision (Basel) 2020; 4:vision4030041. [PMID: 32937750 PMCID: PMC7559075 DOI: 10.3390/vision4030041] [Citation(s) in RCA: 47] [Impact Index Per Article: 11.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/29/2020] [Revised: 08/17/2020] [Accepted: 09/11/2020] [Indexed: 02/07/2023] Open
Abstract
Tilt and decentration of intraocular lenses (IOL) may occur secondary to a complicated cataract surgery or following an uneventful phacoemulsification. Although up to 2–3° tilt and a 0.2–0.3 mm decentration are common and clinically unnoticed for any design of IOL, larger extent of tilt and decentration has a negative impact on the optical performance and subsequently, the patients’ satisfaction. This negative impact does not affect various types of IOLs equally. In this paper we review the methods of measuring IOL tilt and decentration and focus on the effect of IOL tilt and decentration on visual function, in particular visual acuity, dysphotopsia, and wavefront aberrations. Our review found that the methods to measure the IOL displacement have significantly evolved and the available studies have employed different methods in their measurement, while comparability of these methods is questionable. There has been no universal reference point and axis to measure the IOL displacement between different studies. A remarkably high variety and brands of IOLs are used in various studies and occasionally, opposite results are noticed when two different brands of a same design were compared against another IOL design in two studies. We conclude that <5° of inferotemporal tilt is common in both crystalline lenses and IOLs with a correlation between pre- and postoperative lens tilt. IOL tilt has been noticed more frequently with scleral fixated compared with in-the-bag IOLs. IOL decentration has a greater impact than tilt on reduction of visual acuity. There was no correlation between IOL tilt and decentration and dysphotopsia. The advantages of aspheric IOLs are lost when decentration is >0.5 mm. The effect of IOL displacement on visual function is more pronounced in aberration correcting IOLs compared to spherical and standard non-aberration correcting aspherical IOLs and in multifocal versus monofocal IOLs. Internal coma has been frequently associated with IOL tilt and decentration, and this increases with pupil size. There is no correlation between spherical aberration and IOL tilt or decentration. Although IOL tilt produces significant impact on visual outcome in toric IOLs, these lenses are more sensitive to rotation compared to tilt.
Collapse
Affiliation(s)
- Zahra Ashena
- Sussex Eye Hospital, Brighton & Sussex University Hospitals NHS Trust, Eastern Road, Brighton BN2 5BF, UK;
| | - Sundas Maqsood
- Eastbourne District General Hospital, Kings Drive, Eastbourne BN21 2UD, UK;
| | - Syed Naqib Ahmed
- Northampton General Hospital, Cliftonville, Northampton NN1 5BD, UK;
| | - Mayank A. Nanavaty
- Sussex Eye Hospital, Brighton & Sussex University Hospitals NHS Trust, Eastern Road, Brighton BN2 5BF, UK;
- Brighton & Sussex Medical School, University of Sussex, Falmer, Brighton BN1 9PX, UK
- Correspondence: ; Tel.: +44-01273-606126
| |
Collapse
|
11
|
Zhang F, Zhang J, Li W, Zhou L, Feng D, Zhang H, Fang W, Sun R, Liu Z. Correlative Comparison of Three Ocular Axes to Tilt and Decentration of Intraocular Lens and Their Effects on Visual Acuity. Ophthalmic Res 2019; 63:165-173. [PMID: 31846979 DOI: 10.1159/000504716] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/07/2019] [Accepted: 11/10/2019] [Indexed: 11/19/2022]
Abstract
PURPOSE To evaluate which ocular axis, the corneal topographic axis (CTA), pupillary axis (PA) or line of sight (LOS), for measuring the tilt and decentration of intraocular lens (IOL) is most relevant to correct distance visual acuity (CDVA). METHODS A Scheimpflug device (Pentacam HR) was prospectively used to determine the tilt and decentration of IOLs in vivo 3 months after cataract surgery. A new method was developed to reliably measure PA and LOS. We further evaluated CTA and then used Spearman correlation coefficient and linear regression to assess the correlation between CDVA and IOL displacement based on the data of three different ocular axes. RESULTS Forty-six eyes from 46 patients were evaluated. The majority of decentration and tilt of IOL with reference to CTA, PA and LOS were towards the subtemporal direction. We found that the horizontal meridian data measured using CTA and PA were statistically significantly different (p = 0.011 for tilt; p = 0.005 for decentration). The correlation between CDVA and the distance of decentration temporally (r = -0.344, p = 0.035) and inferiorly (r = -0.336, p = 0.042) of the IOL with regard to CTA was significant. PA and LOS measurements had no correlation with any indices. CONCLUSION Assessment of tilt and decentration of the IOL with reference to different ocular axes was markedly different. IOL tilt and decentration measured by CTA were significantly correlated with CDVA.
Collapse
Affiliation(s)
- Fan Zhang
- Department of Ophthalmology, Qingdao Women and Children Hospital, Qingdao University, Qingdao, China.,Department of Ophthalmology, Xuanwu Hospital, Capital Medical University, Beijing, China
| | - Jian Zhang
- Department of Ophthalmology, Xuanwu Hospital, Capital Medical University, Beijing, China,
| | - Wei Li
- Bascom Palmer Eye Institute, University of Miami School of Medicine, Miami, Florida, USA
| | - Lin Zhou
- Department of Ophthalmology, First Hospital of Tsinghua University, Beijing, China
| | - Di Feng
- School of Instrumentation Science and Optoelectronics Engineering, Beihang University, Beijing, China
| | - Haixia Zhang
- Biomechanics, School of Biomedical Engineering, Capital Medical University, Beijing, China.,Biomechanics, Beijing Key Laboratory of Basic Research on Biomechanics in Clinical University, Beijing, China
| | - Wei Fang
- Department of Ophthalmology, Xuanwu Hospital, Capital Medical University, Beijing, China
| | - Ran Sun
- Department of Ophthalmology, Xuanwu Hospital, Capital Medical University, Beijing, China
| | - Zhicheng Liu
- Biomechanics, School of Biomedical Engineering, Capital Medical University, Beijing, China.,Biomechanics, Beijing Key Laboratory of Basic Research on Biomechanics in Clinical University, Beijing, China
| |
Collapse
|
12
|
Fang Y, Xixia D, Jin L, Lei L, Pingjun C, Hongfang Z, Yun-E Z. Relationship of Posterior Capsular Opacification and Capsular Bend Type Investigation Based on Swept-source Optical Coherence Tomography. Curr Eye Res 2019; 45:17-23. [PMID: 31348676 DOI: 10.1080/02713683.2019.1645183] [Citation(s) in RCA: 7] [Impact Index Per Article: 1.4] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/26/2022]
Abstract
Purpose: To investigate the relationship between capsular bend type and posterior capsule opacification (PCO) at a three-dimensional (3D) level using high-speed swept-source optical coherence tomography (SS-OCT).Methods: This was a retrospective study. A total of 99 eyes that underwent standard cataract surgery with phacoemulsification 2 years ago were analyzed. Standard SS-OCT radial scanning was performed in all eyes and the obtained photos were used for morphological observations of the capsular bend-IOL complex, the adhesion of posterior capsule to the IOL optic, and the position of the anterior capsulorhexis. Digital retroillumination photographs were taken of the posterior capsule of each eye to evaluate PCO (scoring and area).Results: In terms of the PCO score and area, there was no statistical difference between eyes with complete and incomplete adhesion of posterior capsule to IOL (both P > .05), whereas the partial overlap group showed a statistical difference greater than the total overlap group (P < .05). There were two types of capsular bends, completed adhesion (CA) and incomplete adhesion (IA). IA was divided into funnel adhesion (IA-F), parallel adhesion (IA-P), and detached adhesion (IA-D). The incomplete adhesion index (IAI) varied between eyes and ranged from 0 to 1. The PCO score and area in the high IAI group (higher than 0.50) were significantly greater than the low IAI group (< 0.50) (P < .05). In addition, the PCO score and area were significantly higher in the cohort with at least one IA-D capsular bend in six districts to the group that did not have IA-D capsular bend (P < .05).Conclusions: Complete or incomplete adhesion of the posterior capsule to the IOL optic may not be necessary for the development of PCO. Our study suggests that capsular bend type may be used as an index to predict PCO.
Collapse
Affiliation(s)
- Yu Fang
- School of Optometry and Ophthalmology and Eye Hospital, Wenzhou Medical University, Wenzhou, Zhejiang, China
| | - Ding Xixia
- School of Optometry and Ophthalmology and Eye Hospital, Wenzhou Medical University, Wenzhou, Zhejiang, China
| | - Li Jin
- School of Optometry and Ophthalmology and Eye Hospital, Wenzhou Medical University, Wenzhou, Zhejiang, China
| | - Lin Lei
- School of Optometry and Ophthalmology and Eye Hospital, Wenzhou Medical University, Wenzhou, Zhejiang, China
| | - Chang Pingjun
- School of Optometry and Ophthalmology and Eye Hospital, Wenzhou Medical University, Wenzhou, Zhejiang, China
| | - Zhang Hongfang
- School of Optometry and Ophthalmology and Eye Hospital, Wenzhou Medical University, Wenzhou, Zhejiang, China
| | - Zhao Yun-E
- School of Optometry and Ophthalmology and Eye Hospital, Wenzhou Medical University, Wenzhou, Zhejiang, China
| |
Collapse
|
13
|
Xixia D, Pingjun C, Hongfang Z, Giacomo S, Jinhai H, Feixue C, A-yong Y, Fang H, Shenghai H, Lei L, Yun-e Z. Three-Dimensional Morphology Study of Capsule in Pseudophakic Eyes with High-Speed Swept-Source Optical Coherence Tomography. Curr Eye Res 2019; 44:607-613. [PMID: 30653366 DOI: 10.1080/02713683.2019.1570275] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/27/2022]
Affiliation(s)
- Ding Xixia
- School of Optometry and Ophthalmology and Eye Hospital, Wenzhou Medical University, Wenzhou, Zhejiang, China
- Key Laboratory of Vision Science, Ministry of Health P.R. China, Wenzhou, Zhejiang, China
| | - Chang Pingjun
- School of Optometry and Ophthalmology and Eye Hospital, Wenzhou Medical University, Wenzhou, Zhejiang, China
- Key Laboratory of Vision Science, Ministry of Health P.R. China, Wenzhou, Zhejiang, China
| | - Zhang Hongfang
- School of Optometry and Ophthalmology and Eye Hospital, Wenzhou Medical University, Wenzhou, Zhejiang, China
- Key Laboratory of Vision Science, Ministry of Health P.R. China, Wenzhou, Zhejiang, China
| | | | - Huang Jinhai
- School of Optometry and Ophthalmology and Eye Hospital, Wenzhou Medical University, Wenzhou, Zhejiang, China
- Key Laboratory of Vision Science, Ministry of Health P.R. China, Wenzhou, Zhejiang, China
| | - Chu Feixue
- School of Optometry and Ophthalmology and Eye Hospital, Wenzhou Medical University, Wenzhou, Zhejiang, China
- Key Laboratory of Vision Science, Ministry of Health P.R. China, Wenzhou, Zhejiang, China
| | - Yu A-yong
- School of Optometry and Ophthalmology and Eye Hospital, Wenzhou Medical University, Wenzhou, Zhejiang, China
- Key Laboratory of Vision Science, Ministry of Health P.R. China, Wenzhou, Zhejiang, China
| | - Huang Fang
- School of Optometry and Ophthalmology and Eye Hospital, Wenzhou Medical University, Wenzhou, Zhejiang, China
- Key Laboratory of Vision Science, Ministry of Health P.R. China, Wenzhou, Zhejiang, China
| | - Huang Shenghai
- School of Optometry and Ophthalmology and Eye Hospital, Wenzhou Medical University, Wenzhou, Zhejiang, China
- Key Laboratory of Vision Science, Ministry of Health P.R. China, Wenzhou, Zhejiang, China
| | - Lin Lei
- School of Optometry and Ophthalmology and Eye Hospital, Wenzhou Medical University, Wenzhou, Zhejiang, China
- Key Laboratory of Vision Science, Ministry of Health P.R. China, Wenzhou, Zhejiang, China
| | - Zhao Yun-e
- School of Optometry and Ophthalmology and Eye Hospital, Wenzhou Medical University, Wenzhou, Zhejiang, China
- Key Laboratory of Vision Science, Ministry of Health P.R. China, Wenzhou, Zhejiang, China
| |
Collapse
|
14
|
Short-term Dynamics after Single- and Three-piece Acrylic Intraocular Lens Implantation: A Swept-source Anterior Segment Optical Coherence Tomography Study. Sci Rep 2018; 8:10230. [PMID: 29980770 PMCID: PMC6035277 DOI: 10.1038/s41598-018-28609-1] [Citation(s) in RCA: 17] [Impact Index Per Article: 2.8] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/26/2018] [Accepted: 06/26/2018] [Indexed: 01/19/2023] Open
Abstract
Accurate alignment of an intraocular lens (IOL) is indispensable for achieving accurate postoperative refractive outcomes. Thus, we evaluated decentration and tilt of single- and three-piece IOLs, as well as anterior chamber depth (ACD), at 3 hours, 24 hours, 2 weeks, and 4 weeks after cataract surgery, using swept-source anterior segment optical coherence tomography. There was no significant difference in postoperative visual acuity between eyes with single- or three-piece IOLs. Absolute values of IOL decentration at 24 hours and 2 weeks after surgery were significantly larger (P = 0.008 and 0.046, respectively) in eyes with the single-piece IOL than in those with the three-piece IOL. Both single- and three-piece IOLs tended to tilt toward the inferotemporal direction; however, there was no significant difference in the absolute values of IOL tilt at any postoperative time point. ACD at 24 hours after surgery was significantly deeper (P = 0.009) in eyes with the three-piece IOL, compared with eyes with the single-piece IOL. Therefore, although both single- and three-piece IOL locations varied transiently after surgery, IOL locations were similar between both IOLs at 4 weeks after surgery and were not associated with any statistical difference in visual function.
Collapse
|
15
|
Assessment of tilt and decentration of crystalline lens and intraocular lens relative to the corneal topographic axis using anterior segment optical coherence tomography. PLoS One 2017; 12:e0184066. [PMID: 28863141 PMCID: PMC5581187 DOI: 10.1371/journal.pone.0184066] [Citation(s) in RCA: 63] [Impact Index Per Article: 9.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/26/2017] [Accepted: 08/17/2017] [Indexed: 12/18/2022] Open
Abstract
Purpose To investigate the tilt and decentration of the crystalline lens and the intraocular lens (IOL) relative to the corneal topographic axis using anterior segment ocular coherence tomography (AS-OCT). Methods A sample set of 100 eyes from 49 subjects (41 eyes with crystalline lenses and 59 eyes with IOLs) were imaged using second generation AS-OCT (CASIA2, TOMEY) in June and July 2016 at Okayama University. Both mydriatic and non-mydriatic images were obtained, and the tilt and decentration of the crystalline lens and the IOL were quantified. The effects of pupil dilation on measurements were also assessed. Results The crystalline lens showed an average tilt of 5.15° towards the inferotemporal direction relative to the corneal topographic axis under non-mydriatic conditions and 5.25° under mydriatic conditions. Additionally, an average decentration of 0.11 mm towards the temporal direction was observed under non-mydriatic conditions and 0.08 mm under mydriatic conditions. The average tilt for the IOL was 4.31° towards the inferotemporal direction relative to the corneal topographic axis under non-mydriatic conditions and 4.65° in the same direction under mydriatic conditions. The average decentration was 0.05 mm towards the temporal direction under non-mydriatic conditions and 0.08 mm in the same direction under mydriatic conditions. A strong correlation was found between the average tilt and decentration values of the crystalline lens and the IOL under both non-mydriatic and mydriatic conditions (all Spearman correlation coefficients, r ≥ 0.800; all P < 0.001). Conclusion When measured using second generation AS-OCT, both the crystalline lens and the IOL showed an average tilt of 4–6° toward the inferotemporal direction relative to the corneal topographic axis and an average decentration of less than 0.12 mm towards the temporal direction. These results were not influenced by pupil dilation and they showed good repeatability.
Collapse
|