1
|
Harris JT, Ward K, Winski A, Elisha E, Lukwaro MG, Muterian Z, Nagatomo K, Wagner C, Radhakrishnan P. Diagnosis and Management of Silicotuberculosis in Resource-Limited East Africa. Cureus 2025; 17:e76961. [PMID: 39906440 PMCID: PMC11793831 DOI: 10.7759/cureus.76961] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Accepted: 01/05/2025] [Indexed: 02/06/2025] Open
Abstract
A 41-year-old East African man with a history of previously treated tuberculosis (TB) presented with hemoptysis, dyspnea, night sweats, and fatigue. He was treated for assumed silicotuberculosis (ST) and made a good recovery. The diagnosis of ST is challenging and requires thorough evaluation due to its overlapping clinical and radiological features with pulmonary TB and silicosis. Its diagnosis and treatment in resource-limited areas is especially complicated and nuanced. Understanding the effects of resource limitation on the diagnosis and treatment of ST can help the medical community address the medical care gap often present in these areas of the world since the region's limited access to advanced diagnostic tools and treatment options exacerbates the burden of the disease.
Collapse
Affiliation(s)
| | - Kaleb Ward
- Family Medicine, HonorHealth, Scottsdale, USA
| | | | | | | | | | | | | | | |
Collapse
|
2
|
Kay AW, Ness T, Verkuijl SE, Viney K, Brands A, Masini T, González Fernández L, Eisenhut M, Detjen AK, Mandalakas AM, Steingart KR, Takwoingi Y. Xpert MTB/RIF Ultra assay for tuberculosis disease and rifampicin resistance in children. Cochrane Database Syst Rev 2022; 9:CD013359. [PMID: 36065889 PMCID: PMC9446385 DOI: 10.1002/14651858.cd013359.pub3] [Citation(s) in RCA: 18] [Impact Index Per Article: 6.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 12/12/2022]
Abstract
BACKGROUND Every year, an estimated one million children and young adolescents become ill with tuberculosis, and around 226,000 of those children die. Xpert MTB/RIF Ultra (Xpert Ultra) is a molecular World Health Organization (WHO)-recommended rapid diagnostic test that simultaneously detects Mycobacterium tuberculosis complex and rifampicin resistance. We previously published a Cochrane Review 'Xpert MTB/RIF and Xpert MTB/RIF Ultra assays for tuberculosis disease and rifampicin resistance in children'. The current review updates evidence on the diagnostic accuracy of Xpert Ultra in children presumed to have tuberculosis disease. Parts of this review update informed the 2022 WHO updated guidance on management of tuberculosis in children and adolescents. OBJECTIVES To assess the diagnostic accuracy of Xpert Ultra for detecting: pulmonary tuberculosis, tuberculous meningitis, lymph node tuberculosis, and rifampicin resistance, in children with presumed tuberculosis. Secondary objectives To investigate potential sources of heterogeneity in accuracy estimates. For detection of tuberculosis, we considered age, comorbidity (HIV, severe pneumonia, and severe malnutrition), and specimen type as potential sources. To summarize the frequency of Xpert Ultra trace results. SEARCH METHODS We searched the Cochrane Infectious Diseases Group Specialized Register, MEDLINE, Embase, three other databases, and three trial registers without language restrictions to 9 March 2021. SELECTION CRITERIA Cross-sectional and cohort studies and randomized trials that evaluated Xpert Ultra in HIV-positive and HIV-negative children under 15 years of age. We included ongoing studies that helped us address the review objectives. We included studies evaluating sputum, gastric, stool, or nasopharyngeal specimens (pulmonary tuberculosis), cerebrospinal fluid (tuberculous meningitis), and fine needle aspirate or surgical biopsy tissue (lymph node tuberculosis). For detecting tuberculosis, reference standards were microbiological (culture) or composite reference standard; for stool, we also included Xpert Ultra performed on a routine respiratory specimen. For detecting rifampicin resistance, reference standards were drug susceptibility testing or MTBDRplus. DATA COLLECTION AND ANALYSIS Two review authors independently extracted data and, using QUADAS-2, assessed methodological quality judging risk of bias separately for each target condition and reference standard. For each target condition, we used the bivariate model to estimate summary sensitivity and specificity with 95% confidence intervals (CIs). We stratified all analyses by type of reference standard. We summarized the frequency of Xpert Ultra trace results; trace represents detection of a very low quantity of Mycobacterium tuberculosis DNA. We assessed certainty of evidence using GRADE. MAIN RESULTS We identified 14 studies (11 new studies since the previous review). For detection of pulmonary tuberculosis, 335 data sets (25,937 participants) were available for analysis. We did not identify any studies that evaluated Xpert Ultra accuracy for tuberculous meningitis or lymph node tuberculosis. Three studies evaluated Xpert Ultra for detection of rifampicin resistance. Ten studies (71%) took place in countries with a high tuberculosis burden based on WHO classification. Overall, risk of bias was low. Detection of pulmonary tuberculosis Sputum, 5 studies Xpert Ultra summary sensitivity verified by culture was 75.3% (95% CI 64.3 to 83.8; 127 participants; high-certainty evidence), and specificity was 97.1% (95% CI 94.7 to 98.5; 1054 participants; high-certainty evidence). Gastric aspirate, 7 studies Xpert Ultra summary sensitivity verified by culture was 70.4% (95% CI 53.9 to 82.9; 120 participants; moderate-certainty evidence), and specificity was 94.1% (95% CI 84.8 to 97.8; 870 participants; moderate-certainty evidence). Stool, 6 studies Xpert Ultra summary sensitivity verified by culture was 56.1% (95% CI 39.1 to 71.7; 200 participants; moderate-certainty evidence), and specificity was 98.0% (95% CI 93.3 to 99.4; 1232 participants; high certainty-evidence). Nasopharyngeal aspirate, 4 studies Xpert Ultra summary sensitivity verified by culture was 43.7% (95% CI 26.7 to 62.2; 46 participants; very low-certainty evidence), and specificity was 97.5% (95% CI 93.6 to 99.0; 489 participants; high-certainty evidence). Xpert Ultra sensitivity was lower against a composite than a culture reference standard for all specimen types other than nasopharyngeal aspirate, while specificity was similar against both reference standards. Interpretation of results In theory, for a population of 1000 children: • where 100 have pulmonary tuberculosis in sputum (by culture): - 101 would be Xpert Ultra-positive, and of these, 26 (26%) would not have pulmonary tuberculosis (false positive); and - 899 would be Xpert Ultra-negative, and of these, 25 (3%) would have tuberculosis (false negative). • where 100 have pulmonary tuberculosis in gastric aspirate (by culture): - 123 would be Xpert Ultra-positive, and of these, 53 (43%) would not have pulmonary tuberculosis (false positive); and - 877 would be Xpert Ultra-negative, and of these, 30 (3%) would have tuberculosis (false negative). • where 100 have pulmonary tuberculosis in stool (by culture): - 74 would be Xpert Ultra-positive, and of these, 18 (24%) would not have pulmonary tuberculosis (false positive); and - 926 would be Xpert Ultra-negative, and of these, 44 (5%) would have tuberculosis (false negative). • where 100 have pulmonary tuberculosis in nasopharyngeal aspirate (by culture): - 66 would be Xpert Ultra-positive, and of these, 22 (33%) would not have pulmonary tuberculosis (false positive); and - 934 would be Xpert Ultra-negative, and of these, 56 (6%) would have tuberculosis (false negative). Detection of rifampicin resistance Xpert Ultra sensitivity was 100% (3 studies, 3 participants; very low-certainty evidence), and specificity range was 97% to 100% (3 studies, 128 participants; low-certainty evidence). Trace results Xpert Ultra trace results, regarded as positive in children by WHO standards, were common. Xpert Ultra specificity remained high in children, despite the frequency of trace results. AUTHORS' CONCLUSIONS We found Xpert Ultra sensitivity to vary by specimen type, with sputum having the highest sensitivity, followed by gastric aspirate and stool. Nasopharyngeal aspirate had the lowest sensitivity. Xpert Ultra specificity was high against both microbiological and composite reference standards. However, the evidence base is still limited, and findings may be imprecise and vary by study setting. Although we found Xpert Ultra accurate for detection of rifampicin resistance, results were based on a very small number of studies that included only three children with rifampicin resistance. Therefore, findings should be interpreted with caution. Our findings provide support for the use of Xpert Ultra as an initial rapid molecular diagnostic in children being evaluated for tuberculosis.
Collapse
Key Words
- adolescent
- child
- humans
- antibiotics, antitubercular
- antibiotics, antitubercular/therapeutic use
- cross-sectional studies
- hiv infections
- hiv infections/drug therapy
- microbial sensitivity tests
- mycobacterium tuberculosis
- mycobacterium tuberculosis/genetics
- rifampin
- rifampin/pharmacology
- sensitivity and specificity
- sputum
- sputum/microbiology
- tuberculosis, lymph node
- tuberculosis, lymph node/diagnosis
- tuberculosis, lymph node/drug therapy
- tuberculosis, meningeal
- tuberculosis, meningeal/cerebrospinal fluid
- tuberculosis, meningeal/diagnosis
- tuberculosis, meningeal/drug therapy
- tuberculosis, pulmonary
- tuberculosis, pulmonary/diagnosis
- tuberculosis, pulmonary/drug therapy
- tuberculosis, pulmonary/microbiology
Collapse
Affiliation(s)
- Alexander W Kay
- The Global Tuberculosis Program, Texas Children's Hospital, Section of Global and Immigrant Health, Department of Pediatrics, Baylor College of Medicine, Houston, Texas, USA
| | - Tara Ness
- The Global Tuberculosis Program, Texas Children's Hospital, Section of Global and Immigrant Health, Department of Pediatrics, Baylor College of Medicine, Houston, Texas, USA
| | | | - Kerri Viney
- Global TB Programme, World Health Organization, Geneva, Switzerland
| | - Annemieke Brands
- Global TB Programme, World Health Organization, Geneva, Switzerland
| | - Tiziana Masini
- Global TB Programme, World Health Organization, Geneva, Switzerland
| | - Lucia González Fernández
- The Global Tuberculosis Program, Texas Children's Hospital, Section of Global and Immigrant Health, Department of Pediatrics, Baylor College of Medicine, Houston, Texas, USA
| | - Michael Eisenhut
- Paediatric Department, Luton & Dunstable University Hospital NHS Foundation Trust, Luton, UK
| | | | - Anna M Mandalakas
- The Global Tuberculosis Program, Texas Children's Hospital, Section of Global and Immigrant Health, Department of Pediatrics, Baylor College of Medicine, Houston, Texas, USA
| | - Karen R Steingart
- Honorary Research Fellow, Department of Clinical Sciences, Liverpool School of Tropical Medicine, Liverpool, UK
| | - Yemisi Takwoingi
- Test Evaluation Research Group, Institute of Applied Health Research, University of Birmingham, Birmingham, UK
| |
Collapse
|
3
|
Kohli M, Schiller I, Dendukuri N, Yao M, Dheda K, Denkinger CM, Schumacher SG, Steingart KR. Xpert MTB/RIF Ultra and Xpert MTB/RIF assays for extrapulmonary tuberculosis and rifampicin resistance in adults. Cochrane Database Syst Rev 2021; 1:CD012768. [PMID: 33448348 PMCID: PMC8078545 DOI: 10.1002/14651858.cd012768.pub3] [Citation(s) in RCA: 47] [Impact Index Per Article: 11.8] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 12/12/2022]
Abstract
BACKGROUND Xpert MTB/RIF Ultra (Xpert Ultra) and Xpert MTB/RIF are World Health Organization (WHO)-recommended rapid nucleic acid amplification tests (NAATs) widely used for simultaneous detection of Mycobacterium tuberculosis complex and rifampicin resistance in sputum. To extend our previous review on extrapulmonary tuberculosis (Kohli 2018), we performed this update to inform updated WHO policy (WHO Consolidated Guidelines (Module 3) 2020). OBJECTIVES To estimate diagnostic accuracy of Xpert Ultra and Xpert MTB/RIF for extrapulmonary tuberculosis and rifampicin resistance in adults with presumptive extrapulmonary tuberculosis. SEARCH METHODS Cochrane Infectious Diseases Group Specialized Register, MEDLINE, Embase, Science Citation Index, Web of Science, Latin American Caribbean Health Sciences Literature, Scopus, ClinicalTrials.gov, the WHO International Clinical Trials Registry Platform, the International Standard Randomized Controlled Trial Number Registry, and ProQuest, 2 August 2019 and 28 January 2020 (Xpert Ultra studies), without language restriction. SELECTION CRITERIA Cross-sectional and cohort studies using non-respiratory specimens. Forms of extrapulmonary tuberculosis: tuberculous meningitis and pleural, lymph node, bone or joint, genitourinary, peritoneal, pericardial, disseminated tuberculosis. Reference standards were culture and a study-defined composite reference standard (tuberculosis detection); phenotypic drug susceptibility testing and line probe assays (rifampicin resistance detection). DATA COLLECTION AND ANALYSIS Two review authors independently extracted data and assessed risk of bias and applicability using QUADAS-2. For tuberculosis detection, we performed separate analyses by specimen type and reference standard using the bivariate model to estimate pooled sensitivity and specificity with 95% credible intervals (CrIs). We applied a latent class meta-analysis model to three forms of extrapulmonary tuberculosis. We assessed certainty of evidence using GRADE. MAIN RESULTS 69 studies: 67 evaluated Xpert MTB/RIF and 11 evaluated Xpert Ultra, of which nine evaluated both tests. Most studies were conducted in China, India, South Africa, and Uganda. Overall, risk of bias was low for patient selection, index test, and flow and timing domains, and low (49%) or unclear (43%) for the reference standard domain. Applicability for the patient selection domain was unclear for most studies because we were unsure of the clinical settings. Cerebrospinal fluid Xpert Ultra (6 studies) Xpert Ultra pooled sensitivity and specificity (95% CrI) against culture were 89.4% (79.1 to 95.6) (89 participants; low-certainty evidence) and 91.2% (83.2 to 95.7) (386 participants; moderate-certainty evidence). Of 1000 people where 100 have tuberculous meningitis, 168 would be Xpert Ultra-positive: of these, 79 (47%) would not have tuberculosis (false-positives) and 832 would be Xpert Ultra-negative: of these, 11 (1%) would have tuberculosis (false-negatives). Xpert MTB/RIF (30 studies) Xpert MTB/RIF pooled sensitivity and specificity against culture were 71.1% (62.8 to 79.1) (571 participants; moderate-certainty evidence) and 96.9% (95.4 to 98.0) (2824 participants; high-certainty evidence). Of 1000 people where 100 have tuberculous meningitis, 99 would be Xpert MTB/RIF-positive: of these, 28 (28%) would not have tuberculosis; and 901 would be Xpert MTB/RIF-negative: of these, 29 (3%) would have tuberculosis. Pleural fluid Xpert Ultra (4 studies) Xpert Ultra pooled sensitivity and specificity against culture were 75.0% (58.0 to 86.4) (158 participants; very low-certainty evidence) and 87.0% (63.1 to 97.9) (240 participants; very low-certainty evidence). Of 1000 people where 100 have pleural tuberculosis, 192 would be Xpert Ultra-positive: of these, 117 (61%) would not have tuberculosis; and 808 would be Xpert Ultra-negative: of these, 25 (3%) would have tuberculosis. Xpert MTB/RIF (25 studies) Xpert MTB/RIF pooled sensitivity and specificity against culture were 49.5% (39.8 to 59.9) (644 participants; low-certainty evidence) and 98.9% (97.6 to 99.7) (2421 participants; high-certainty evidence). Of 1000 people where 100 have pleural tuberculosis, 60 would be Xpert MTB/RIF-positive: of these, 10 (17%) would not have tuberculosis; and 940 would be Xpert MTB/RIF-negative: of these, 50 (5%) would have tuberculosis. Lymph node aspirate Xpert Ultra (1 study) Xpert Ultra sensitivity and specificity (95% confidence interval) against composite reference standard were 70% (51 to 85) (30 participants; very low-certainty evidence) and 100% (92 to 100) (43 participants; low-certainty evidence). Of 1000 people where 100 have lymph node tuberculosis, 70 would be Xpert Ultra-positive and 0 (0%) would not have tuberculosis; 930 would be Xpert Ultra-negative and 30 (3%) would have tuberculosis. Xpert MTB/RIF (4 studies) Xpert MTB/RIF pooled sensitivity and specificity against composite reference standard were 81.6% (61.9 to 93.3) (377 participants; low-certainty evidence) and 96.4% (91.3 to 98.6) (302 participants; low-certainty evidence). Of 1000 people where 100 have lymph node tuberculosis, 118 would be Xpert MTB/RIF-positive and 37 (31%) would not have tuberculosis; 882 would be Xpert MTB/RIF-negative and 19 (2%) would have tuberculosis. In lymph node aspirate, Xpert MTB/RIF pooled specificity against culture was 86.2% (78.0 to 92.3), lower than that against a composite reference standard. Using the latent class model, Xpert MTB/RIF pooled specificity was 99.5% (99.1 to 99.7), similar to that observed with a composite reference standard. Rifampicin resistance Xpert Ultra (4 studies) Xpert Ultra pooled sensitivity and specificity were 100.0% (95.1 to 100.0), (24 participants; low-certainty evidence) and 100.0% (99.0 to 100.0) (105 participants; moderate-certainty evidence). Of 1000 people where 100 have rifampicin resistance, 100 would be Xpert Ultra-positive (resistant): of these, zero (0%) would not have rifampicin resistance; and 900 would be Xpert Ultra-negative (susceptible): of these, zero (0%) would have rifampicin resistance. Xpert MTB/RIF (19 studies) Xpert MTB/RIF pooled sensitivity and specificity were 96.5% (91.9 to 98.8) (148 participants; high-certainty evidence) and 99.1% (98.0 to 99.7) (822 participants; high-certainty evidence). Of 1000 people where 100 have rifampicin resistance, 105 would be Xpert MTB/RIF-positive (resistant): of these, 8 (8%) would not have rifampicin resistance; and 895 would be Xpert MTB/RIF-negative (susceptible): of these, 3 (0.3%) would have rifampicin resistance. AUTHORS' CONCLUSIONS Xpert Ultra and Xpert MTB/RIF may be helpful in diagnosing extrapulmonary tuberculosis. Sensitivity varies across different extrapulmonary specimens: while for most specimens specificity is high, the tests rarely yield a positive result for people without tuberculosis. For tuberculous meningitis, Xpert Ultra had higher sensitivity and lower specificity than Xpert MTB/RIF against culture. Xpert Ultra and Xpert MTB/RIF had similar sensitivity and specificity for rifampicin resistance. Future research should acknowledge the concern associated with culture as a reference standard in paucibacillary specimens and consider ways to address this limitation.
Collapse
MESH Headings
- Adult
- Antibiotics, Antitubercular/therapeutic use
- Bias
- Drug Resistance, Bacterial
- False Negative Reactions
- False Positive Reactions
- Humans
- Mycobacterium tuberculosis/drug effects
- Mycobacterium tuberculosis/isolation & purification
- Nucleic Acid Amplification Techniques/methods
- Nucleic Acid Amplification Techniques/statistics & numerical data
- Reagent Kits, Diagnostic
- Rifampin/therapeutic use
- Sensitivity and Specificity
- Tuberculosis/cerebrospinal fluid
- Tuberculosis/diagnosis
- Tuberculosis/drug therapy
- Tuberculosis, Lymph Node/cerebrospinal fluid
- Tuberculosis, Lymph Node/diagnosis
- Tuberculosis, Lymph Node/drug therapy
- Tuberculosis, Meningeal/cerebrospinal fluid
- Tuberculosis, Meningeal/diagnosis
- Tuberculosis, Meningeal/drug therapy
- Tuberculosis, Multidrug-Resistant/cerebrospinal fluid
- Tuberculosis, Multidrug-Resistant/diagnosis
- Tuberculosis, Multidrug-Resistant/drug therapy
- Tuberculosis, Pleural/cerebrospinal fluid
- Tuberculosis, Pleural/diagnosis
- Tuberculosis, Pleural/drug therapy
Collapse
Affiliation(s)
- Mikashmi Kohli
- Department of Epidemiology, Biostatistics and Occupational Health, McGill University, Montreal, Canada
| | - Ian Schiller
- Centre for Outcomes Research, McGill University Health Centre - Research Institute, Montreal, Canada
| | - Nandini Dendukuri
- Centre for Outcomes Research, McGill University Health Centre - Research Institute, Montreal, Canada
| | - Mandy Yao
- Centre for Outcomes Research, McGill University Health Centre - Research Institute, Montreal, Canada
| | - Keertan Dheda
- Centre for Lung Infection and Immunity Unit, Department of Medicine and UCT Lung Institute, University of Cape Town, Cape Town, South Africa
- Faculty of Infectious and Tropical Diseases, Department of Immunology and Infection, London School of Hygiene and Tropical Medicine, London, UK
| | - Claudia M Denkinger
- FIND, Geneva , Switzerland
- Division of Tropical Medicine, Centre for Infectious Diseases, University Hospital Heidelberg, Heidelberg, Germany
| | | | - Karen R Steingart
- Honorary Research Fellow, Department of Clinical Sciences, Liverpool School of Tropical Medicine, Liverpool, UK
| |
Collapse
|
4
|
Kay AW, González Fernández L, Takwoingi Y, Eisenhut M, Detjen AK, Steingart KR, Mandalakas AM. Xpert MTB/RIF and Xpert MTB/RIF Ultra assays for active tuberculosis and rifampicin resistance in children. Cochrane Database Syst Rev 2020; 8:CD013359. [PMID: 32853411 PMCID: PMC8078611 DOI: 10.1002/14651858.cd013359.pub2] [Citation(s) in RCA: 20] [Impact Index Per Article: 4.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 01/17/2023]
Abstract
BACKGROUND Every year, at least one million children become ill with tuberculosis and around 200,000 children die. Xpert MTB/RIF and Xpert Ultra are World Health Organization (WHO)-recommended rapid molecular tests that simultaneously detect tuberculosis and rifampicin resistance in adults and children with signs and symptoms of tuberculosis, at lower health system levels. To inform updated WHO guidelines on molecular assays, we performed a systematic review on the diagnostic accuracy of these tests in children presumed to have active tuberculosis. OBJECTIVES Primary objectives • To determine the diagnostic accuracy of Xpert MTB/RIF and Xpert Ultra for (a) pulmonary tuberculosis in children presumed to have tuberculosis; (b) tuberculous meningitis in children presumed to have tuberculosis; (c) lymph node tuberculosis in children presumed to have tuberculosis; and (d) rifampicin resistance in children presumed to have tuberculosis - For tuberculosis detection, index tests were used as the initial test, replacing standard practice (i.e. smear microscopy or culture) - For detection of rifampicin resistance, index tests replaced culture-based drug susceptibility testing as the initial test Secondary objectives • To compare the accuracy of Xpert MTB/RIF and Xpert Ultra for each of the four target conditions • To investigate potential sources of heterogeneity in accuracy estimates - For tuberculosis detection, we considered age, disease severity, smear-test status, HIV status, clinical setting, specimen type, high tuberculosis burden, and high tuberculosis/HIV burden - For detection of rifampicin resistance, we considered multi-drug-resistant tuberculosis burden • To compare multiple Xpert MTB/RIF or Xpert Ultra results (repeated testing) with the initial Xpert MTB/RIF or Xpert Ultra result SEARCH METHODS: We searched the Cochrane Infectious Diseases Group Specialized Register, MEDLINE, Embase, Science Citation Index, the Cumulative Index to Nursing and Allied Health Literature (CINAHL), Scopus, the WHO International Clinical Trials Registry Platform, ClinicalTrials.gov, and the International Standard Randomized Controlled Trials Number (ISRCTN) Registry up to 29 April 2019, without language restrictions. SELECTION CRITERIA Randomized trials, cross-sectional trials, and cohort studies evaluating Xpert MTB/RIF or Xpert Ultra in HIV-positive and HIV-negative children younger than 15 years. Reference standards comprised culture or a composite reference standard for tuberculosis and drug susceptibility testing or MTBDRplus (molecular assay for detection of Mycobacterium tuberculosis and drug resistance) for rifampicin resistance. We included studies evaluating sputum, gastric aspirate, stool, nasopharyngeal or bronchial lavage specimens (pulmonary tuberculosis), cerebrospinal fluid (tuberculous meningitis), fine needle aspirates, or surgical biopsy tissue (lymph node tuberculosis). DATA COLLECTION AND ANALYSIS Two review authors independently extracted data and assessed study quality using the Quality Assessment of Studies of Diagnostic Accuracy - Revised (QUADAS-2). For each target condition, we used the bivariate model to estimate pooled sensitivity and specificity with 95% confidence intervals (CIs). We stratified all analyses by type of reference standard. We assessed certainty of evidence using the GRADE approach. MAIN RESULTS For pulmonary tuberculosis, 299 data sets (68,544 participants) were available for analysis; for tuberculous meningitis, 10 data sets (423 participants) were available; for lymph node tuberculosis, 10 data sets (318 participants) were available; and for rifampicin resistance, 14 data sets (326 participants) were available. Thirty-nine studies (80%) took place in countries with high tuberculosis burden. Risk of bias was low except for the reference standard domain, for which risk of bias was unclear because many studies collected only one specimen for culture. Detection of pulmonary tuberculosis For sputum specimens, Xpert MTB/RIF pooled sensitivity (95% CI) and specificity (95% CI) verified by culture were 64.6% (55.3% to 72.9%) (23 studies, 493 participants; moderate-certainty evidence) and 99.0% (98.1% to 99.5%) (23 studies, 6119 participants; moderate-certainty evidence). For other specimen types (nasopharyngeal aspirate, 4 studies; gastric aspirate, 14 studies; stool, 11 studies), Xpert MTB/RIF pooled sensitivity ranged between 45.7% and 73.0%, and pooled specificity ranged between 98.1% and 99.6%. For sputum specimens, Xpert Ultra pooled sensitivity (95% CI) and specificity (95% CI) verified by culture were 72.8% (64.7% to 79.6%) (3 studies, 136 participants; low-certainty evidence) and 97.5% (95.8% to 98.5%) (3 studies, 551 participants; high-certainty evidence). For nasopharyngeal specimens, Xpert Ultra sensitivity (95% CI) and specificity (95% CI) were 45.7% (28.9% to 63.3%) and 97.5% (93.7% to 99.3%) (1 study, 195 participants). For all specimen types, Xpert MTB/RIF and Xpert Ultra sensitivity were lower against a composite reference standard than against culture. Detection of tuberculous meningitis For cerebrospinal fluid, Xpert MTB/RIF pooled sensitivity and specificity, verified by culture, were 54.0% (95% CI 27.8% to 78.2%) (6 studies, 28 participants; very low-certainty evidence) and 93.8% (95% CI 84.5% to 97.6%) (6 studies, 213 participants; low-certainty evidence). Detection of lymph node tuberculosis For lymph node aspirates or biopsies, Xpert MTB/RIF pooled sensitivity and specificity, verified by culture, were 90.4% (95% CI 55.7% to 98.6%) (6 studies, 68 participants; very low-certainty evidence) and 89.8% (95% CI 71.5% to 96.8%) (6 studies, 142 participants; low-certainty evidence). Detection of rifampicin resistance Xpert MTB/RIF pooled sensitivity and specificity were 90.0% (67.6% to 97.5%) (6 studies, 20 participants; low-certainty evidence) and 98.3% (87.7% to 99.8%) (6 studies, 203 participants; moderate-certainty evidence). AUTHORS' CONCLUSIONS We found Xpert MTB/RIF sensitivity to vary by specimen type, with gastric aspirate specimens having the highest sensitivity followed by sputum and stool, and nasopharyngeal specimens the lowest; specificity in all specimens was > 98%. Compared with Xpert MTB/RIF, Xpert Ultra sensitivity in sputum was higher and specificity slightly lower. Xpert MTB/RIF was accurate for detection of rifampicin resistance. Xpert MTB/RIF was sensitive for diagnosing lymph node tuberculosis. For children with presumed tuberculous meningitis, treatment decisions should be based on the entirety of clinical information and treatment should not be withheld based solely on an Xpert MTB/RIF result. The small numbers of studies and participants, particularly for Xpert Ultra, limits our confidence in the precision of these estimates.
Collapse
MESH Headings
- Adolescent
- Antibiotics, Antitubercular/therapeutic use
- Bias
- Child
- Feces/microbiology
- Gastrointestinal Contents/microbiology
- Humans
- Molecular Typing/methods
- Molecular Typing/standards
- Mycobacterium tuberculosis/drug effects
- Mycobacterium tuberculosis/isolation & purification
- Rifampin/therapeutic use
- Sensitivity and Specificity
- Sputum/microbiology
- Tuberculosis, Lymph Node/diagnosis
- Tuberculosis, Lymph Node/drug therapy
- Tuberculosis, Lymph Node/microbiology
- Tuberculosis, Meningeal/cerebrospinal fluid
- Tuberculosis, Meningeal/diagnosis
- Tuberculosis, Meningeal/drug therapy
- Tuberculosis, Meningeal/microbiology
- Tuberculosis, Multidrug-Resistant/diagnosis
- Tuberculosis, Multidrug-Resistant/drug therapy
- Tuberculosis, Multidrug-Resistant/microbiology
- Tuberculosis, Pulmonary/diagnosis
- Tuberculosis, Pulmonary/drug therapy
- Tuberculosis, Pulmonary/microbiology
Collapse
Affiliation(s)
- Alexander W Kay
- The Global Tuberculosis Program, Texas Children's Hospital, Section of Global and Immigrant Health, Department of Pediatrics, Baylor College of Medicine, Houston, Texas, USA
| | | | - Yemisi Takwoingi
- Test Evaluation Research Group, Institute of Applied Health Research, University of Birmingham, Birmingham, UK
| | - Michael Eisenhut
- Paediatric Department, Luton & Dunstable University Hospital NHS Foundation Trust, Luton, UK
| | | | - Karen R Steingart
- Honorary Research Fellow, Department of Clinical Sciences, Liverpool School of Tropical Medicine, Liverpool, UK
| | - Anna M Mandalakas
- The Global Tuberculosis Program, Texas Children's Hospital, Section of Global and Immigrant Health, Department of Pediatrics, Baylor College of Medicine, Houston, Texas, USA
| |
Collapse
|
5
|
Wei Z, Zhang X, Wei C, Yao L, Li Y, Zhang X, Xu H, Jia Y, Guo R, Wu Y, Yang K, Gao X. Diagnostic accuracy of in-house real-time PCR assay for Mycobacterium tuberculosis: a systematic review and meta-analysis. BMC Infect Dis 2019; 19:701. [PMID: 31395014 PMCID: PMC6686366 DOI: 10.1186/s12879-019-4273-z] [Citation(s) in RCA: 17] [Impact Index Per Article: 2.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/12/2017] [Accepted: 07/10/2019] [Indexed: 11/10/2022] Open
Abstract
BACKGROUND In recent years, studies on the diagnostic accuracy of in-house real-time PCR (hRT-PCR) assay for the detection of Mycobacterium tuberculosis (Mtb) have been reported with unignorable discrepancies. To assess the overall accuracy of the hRT-PCR assay for Mtb diagnosis in different samples for individuals with active pulmonary and extra-pulmonary Mtb infection, a systematic review and meta-analysis were performed. METHODS The PUBMED, EMBASE, Web of Science, and Cochrane databases were searched up to June 2017 for eligible studies that estimated diagnostic sensitivity and specificity with the hRT-PCR assay in respiratory and non-respiratory samples in pulmonary and extra-pulmonary Mtb infection patients, with Mtb culture as the reference standard. Bivariate random effect models were used to provide pooled estimation of diagnostic accuracy. Further, subgroup and meta-regression analyses were performed to explore sources of heterogeneity. The risk of bias was assessed by the QUADAS-2 tool. RESULTS Of the 3589 candidate studies, 18 eligible studies met our inclusion criteria. Compared to Mtb culture data, the pooled sensitivity and specificity were 0.96 and 0.92, respectively. The diagnostic odds ratio (DOR) was 192.96 (95% CI 68.46, 543.90), and the area under the summary ROC curve (AUC) was 0.9791. There was significant heterogeneity in sensitivity and specificity among the enrolled studies (p < 0.001). The studies with high-quality assessment and application of respiratory specimen were associated with better accuracy. CONCLUSIONS In low-income/high-burden settings, our results suggested that the hRT-PCR assay could be a useful test for the diagnosis of TB with high sensitivity and specificity.
Collapse
Affiliation(s)
- Zhenhong Wei
- Blood Transfusion Department, Gansu Provincial Hospital, Lanzhou, 730000, Gansu, China
| | - Xiaoping Zhang
- Blood Transfusion Department, Gansu Provincial Hospital, Lanzhou, 730000, Gansu, China
| | - Chaojun Wei
- The Institute of Clinical Research and Translational Medicine, Gansu Provincial Hospital, No. 204, Donggang street, Chengguan district, Lanzhou, 730000, Gansu, China
| | - Liang Yao
- The Institute of Clinical Study and Evidence-Based Medicine, Gansu Provincial Hospital, Lanzhou, 730000, Gansu, China.,Evidence-Based Medicine Center and Key Laboratory of Evidence-Based Medicine and Knowledge Translation of Gansu Province, College of Basic Medicine, Lanzhou University, No. 199, Donggang street, Chengguan district, Lanzhou, 73000, Gansu, China
| | - Yonghong Li
- The Institute of Clinical Research and Translational Medicine, Gansu Provincial Hospital, No. 204, Donggang street, Chengguan district, Lanzhou, 730000, Gansu, China
| | - Xiaojing Zhang
- Blood Transfusion Department, Gansu Provincial Hospital, Lanzhou, 730000, Gansu, China
| | - Hui Xu
- The Institute of Clinical Research and Translational Medicine, Gansu Provincial Hospital, No. 204, Donggang street, Chengguan district, Lanzhou, 730000, Gansu, China
| | - Yanjuan Jia
- The Institute of Clinical Research and Translational Medicine, Gansu Provincial Hospital, No. 204, Donggang street, Chengguan district, Lanzhou, 730000, Gansu, China
| | - Rui Guo
- The Institute of Clinical Research and Translational Medicine, Gansu Provincial Hospital, No. 204, Donggang street, Chengguan district, Lanzhou, 730000, Gansu, China
| | - Yu Wu
- The Institute of Clinical Research and Translational Medicine, Gansu Provincial Hospital, No. 204, Donggang street, Chengguan district, Lanzhou, 730000, Gansu, China
| | - Kehu Yang
- The Institute of Clinical Study and Evidence-Based Medicine, Gansu Provincial Hospital, Lanzhou, 730000, Gansu, China. .,Evidence-Based Medicine Center and Key Laboratory of Evidence-Based Medicine and Knowledge Translation of Gansu Province, College of Basic Medicine, Lanzhou University, No. 199, Donggang street, Chengguan district, Lanzhou, 73000, Gansu, China.
| | - Xiaoling Gao
- The Institute of Clinical Research and Translational Medicine, Gansu Provincial Hospital, No. 204, Donggang street, Chengguan district, Lanzhou, 730000, Gansu, China.
| |
Collapse
|
6
|
Kohli M, Schiller I, Dendukuri N, Dheda K, Denkinger CM, Schumacher SG, Steingart KR. Xpert ® MTB/RIF assay for extrapulmonary tuberculosis and rifampicin resistance. Cochrane Database Syst Rev 2018; 8:CD012768. [PMID: 30148542 PMCID: PMC6513199 DOI: 10.1002/14651858.cd012768.pub2] [Citation(s) in RCA: 132] [Impact Index Per Article: 18.9] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 12/11/2022]
Abstract
BACKGROUND Tuberculosis (TB) is the world's leading infectious cause of death. Extrapulmonary TB accounts for 15% of TB cases, but the proportion is increasing, and over half a million people were newly diagnosed with rifampicin-resistant TB in 2016. Xpert® MTB/RIF (Xpert) is a World Health Organization (WHO)-recommended, rapid, automated, nucleic acid amplification assay that is used widely for simultaneous detection of Mycobacterium tuberculosis complex and rifampicin resistance in sputum specimens. This Cochrane Review assessed the accuracy of Xpert in extrapulmonary specimens. OBJECTIVES To determine the diagnostic accuracy of Xpert a) for extrapulmonary TB by site of disease in people presumed to have extrapulmonary TB; and b) for rifampicin resistance in people presumed to have extrapulmonary TB. SEARCH METHODS We searched the Cochrane Infectious Diseases Group Specialized Register, MEDLINE, Embase, Science Citation Index, Web of Science, Latin American Caribbean Health Sciences Literature (LILACS), Scopus, ClinicalTrials.gov, the WHO International Clinical Trials Registry Platform, the International Standard Randomized Controlled Trial Number (ISRCTN) Registry, and ProQuest up to 7 August 2017 without language restriction. SELECTION CRITERIA We included diagnostic accuracy studies of Xpert in people presumed to have extrapulmonary TB. We included TB meningitis and pleural, lymph node, bone or joint, genitourinary, peritoneal, pericardial, and disseminated TB. We used culture as the reference standard. For pleural TB, we also included a composite reference standard, which defined a positive result as the presence of granulomatous inflammation or a positive culture result. For rifampicin resistance, we used culture-based drug susceptibility testing or MTBDRplus as the reference standard. DATA COLLECTION AND ANALYSIS Two review authors independently extracted data, assessed risk of bias and applicability using the QUADAS-2 tool. We determined pooled predicted sensitivity and specificity for TB, grouped by type of extrapulmonary specimen, and for rifampicin resistance. For TB detection, we used a bivariate random-effects model. Recognizing that use of culture may lead to misclassification of cases of extrapulmonary TB as 'not TB' owing to the paucibacillary nature of the disease, we adjusted accuracy estimates by applying a latent class meta-analysis model. For rifampicin resistance detection, we performed univariate meta-analyses for sensitivity and specificity separately to include studies in which no rifampicin resistance was detected. We used theoretical populations with an assumed prevalence to provide illustrative numbers of patients with false positive and false negative results. MAIN RESULTS We included 66 unique studies that evaluated 16,213 specimens for detection of extrapulmonary TB and rifampicin resistance. We identified only one study that evaluated the newest test version, Xpert MTB/RIF Ultra (Ultra), for TB meningitis. Fifty studies (76%) took place in low- or middle-income countries. Risk of bias was low for patient selection, index test, and flow and timing domains and was high or unclear for the reference standard domain (most of these studies decontaminated sterile specimens before culture inoculation). Regarding applicability, in the patient selection domain, we scored high or unclear concern for most studies because either patients were evaluated exclusively as inpatients at tertiary care centres, or we were not sure about the clinical settings.Pooled Xpert sensitivity (defined by culture) varied across different types of specimens (31% in pleural tissue to 97% in bone or joint fluid); Xpert sensitivity was > 80% in urine and bone or joint fluid and tissue. Pooled Xpert specificity (defined by culture) varied less than sensitivity (82% in bone or joint tissue to 99% in pleural fluid and urine). Xpert specificity was ≥ 98% in cerebrospinal fluid, pleural fluid, urine, and peritoneal fluid.Xpert testing in cerebrospinal fluidXpert pooled sensitivity and specificity (95% credible interval (CrI)) against culture were 71.1% (60.9% to 80.4%) and 98.0% (97.0% to 98.8%), respectively (29 studies, 3774 specimens; moderate-certainty evidence).For a population of 1000 people where 100 have TB meningitis on culture, 89 would be Xpert-positive: of these, 18 (20%) would not have TB (false-positives); and 911 would be Xpert-negative: of these, 29 (3%) would have TB (false-negatives).For TB meningitis, ultra sensitivity and specificity against culture (95% confidence interval (CI)) were 90% (55% to 100%) and 90% (83% to 95%), respectively (one study, 129 participants).Xpert testing in pleural fluidXpert pooled sensitivity and specificity (95% CrI) against culture were 50.9% (39.7% to 62.8%) and 99.2% (98.2% to 99.7%), respectively (27 studies, 4006 specimens; low-certainty evidence).For a population of 1000 people where 150 have pleural TB on culture, 83 would be Xpert-positive: of these, seven (8%) would not have TB (false-positives); and 917 would be Xpert-negative: of these, 74 (8%) would have TB (false-negatives).Xpert testing in urineXpert pooled sensitivity and specificity (95% CrI) against culture were 82.7% (69.6% to 91.1%) and 98.7% (94.8% to 99.7%), respectively (13 studies, 1199 specimens; moderate-certainty evidence).For a population of 1000 people where 70 have genitourinary TB on culture, 70 would be Xpert-positive: of these, 12 (17%) would not have TB (false-positives); and 930 would be Xpert-negative: of these, 12 (1%) would have TB (false-negatives).Xpert testing for rifampicin resistanceXpert pooled sensitivity (20 studies, 148 specimens) and specificity (39 studies, 1088 specimens) were 95.0% (89.7% to 97.9%) and 98.7% (97.8% to 99.4%), respectively (high-certainty evidence).For a population of 1000 people where 120 have rifampicin-resistant TB, 125 would be positive for rifampicin-resistant TB: of these, 11 (9%) would not have rifampicin resistance (false-positives); and 875 would be negative for rifampicin-resistant TB: of these, 6 (1%) would have rifampicin resistance (false-negatives).For lymph node TB, the accuracy of culture, the reference standard used, presented a greater concern for bias than in other forms of extrapulmonary TB. AUTHORS' CONCLUSIONS In people presumed to have extrapulmonary TB, Xpert may be helpful in confirming the diagnosis. Xpert sensitivity varies across different extrapulmonary specimens, while for most specimens, specificity is high, the test rarely yielding a positive result for people without TB (defined by culture). Xpert is accurate for detection of rifampicin resistance. For people with presumed TB meningitis, treatment should be based on clinical judgement, and not withheld solely on an Xpert result, as is common practice when culture results are negative.
Collapse
Affiliation(s)
- Mikashmi Kohli
- McGill UniversityDepartment of Epidemiology, Biostatistics and Occupational HealthMontrealCanada
| | - Ian Schiller
- McGill University Health Centre ‐ Research InstituteDivision of Clinical EpidemiologyMontrealCanada
| | - Nandini Dendukuri
- McGill University Health Centre ‐ Research InstituteDivision of Clinical EpidemiologyMontrealCanada
| | - Keertan Dheda
- University of Cape Town3 Centre for Lung Infection and Immunity Unit, Department of Medicine and UCT Lung InstituteCape TownSouth Africa
| | | | | | - Karen R Steingart
- Department of Clinical Sciences, Liverpool School of Tropical MedicineHonorary Research FellowPembroke PlaceLiverpoolUK
| |
Collapse
|
7
|
Datta S, Budhauliya R, Chatterjee S, Veer V, Chakravarty R. Enhancement of PCR Detection Limit by Single-Tube Restriction Endonuclease-PCR (RE-PCR). Mol Diagn Ther 2016; 20:297-305. [PMID: 26993322 DOI: 10.1007/s40291-016-0195-2] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/26/2022]
Abstract
BACKGROUND Polymerase chain reaction (PCR) is widely used in biological research and diagnostics because of its high sensitivity and specificity. However, the sensitivity of PCR is strongly influenced by topological characteristics of the template. Supercoiled templates are known to inhibit PCR, whereas linearized forms of the same supercoiled templates facilitate PCR. OBJECTIVES This study was conducted to compare the PCR efficiency of circular supercoiled DNA templates to their restriction endonuclease (RE)-mediated linearized forms. Additionally, we also evaluated the possibility of RE digestion of the circular supercoiled templates within the complete PCR buffer. METHODS Following a systematic approach, we demonstrated that circular supercoiled templates could be efficiently linearized by RE in the complete PCR buffer itself. This allowed linearization of circular supercoiled templates and their subsequent amplification in the PCR buffer in a single-tube format. RESULTS Using this extremely simple RE-PCR approach, we documented up to tenfold increases in detection efficiency of PCR with two different circular supercoiled templates of clinical origin, including an international calibration standard. CONCLUSIONS This inexpensive and easy approach to increasing PCR sensitivity can be easily adapted to any standard PCR protocol aimed at amplifying circular supercoiled genomes. Apart from its application in the development of sensitive clinical diagnostic PCR assays for a large number of organisms, this method could also prove to be very useful in simplifying the existing protocols for other applications where pre-PCR restriction digestion is required, such as mutation detection, genotyping, and selective template amplification.
Collapse
Affiliation(s)
- Sibnarayan Datta
- Molecular Virology Laboratory, Defence Research Laboratory (DRDO), Tezpur, Assam, 784001, India.
| | - Raghvendra Budhauliya
- Molecular Virology Laboratory, Defence Research Laboratory (DRDO), Tezpur, Assam, 784001, India
| | - Soumya Chatterjee
- Molecular Virology Laboratory, Defence Research Laboratory (DRDO), Tezpur, Assam, 784001, India
| | - Vijay Veer
- Molecular Virology Laboratory, Defence Research Laboratory (DRDO), Tezpur, Assam, 784001, India
| | - Runu Chakravarty
- Hepatitis Research Laboratory, ICMR Virus Unit, Kolkata (ICMR), Kolkata, 700010, West Bengal, India
| |
Collapse
|