Ito K, Ishikawa Y, Teramura S, Yamada T. Feasibility of the analytical dose calculation method for Au-198 brachytherapy. Phys Med 2024; 125:104501. [PMID: 39217788 DOI: 10.1016/j.ejmp.2024.104501] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 10/12/2023] [Revised: 06/22/2024] [Accepted: 08/22/2024] [Indexed: 09/04/2024] Open
Abstract
PURPOSE A dose calculation algorithm Computed Tomography (CT)-based analytical dose calculation method (CTanly), which can correct for subject inhomogeneity and size-dependent scatter doses, was applied to the 198Au seed. In this study, we evaluated the effectiveness of the CTanly method by comparing the gold standard Monte Carlo (MC) method and the conventional TG43 method on two virtual phantoms and patient CT images simulating oral cancer. METHODS As virtual phantoms, a water phantom and a heterogeneous phantom with soft tissue inserted cubic fat, lung, and bone were used. A 2-mm-thick lead plate was also inserted into the heterogeneous phantom as a dose attenuator. Virtual 198Au seeds and a 2-mm-thick lead plate were placed on the patient CT images. Dose distributions obtained via the TG43 and CTanly methods were compared with those of the MC by gamma analysis with 2%/2-mm thresholds. The computation durations were also compared. RESULTS In the water phantom, dose distributions comparable to those obtained via the MC method were obtained regardless of the algorithm. For the inhomogeneity phantom and patient case, the CTanly method showed an improvement in the gamma passing rate and dose distributions similar to those of the MC method were obtained. The computation time, which was days with the MC method, was reduced to minutes with the CTanly method. CONCLUSIONS The CTanly method is effective for 198Au seed dose calculations and takes a shorter time to obtain the dose distributions than the MC method.
Collapse
Affiliation(s)
- Kengo Ito
- Division of Radiology, Tohoku Medical and Pharmaceutical University, Sendai, Miyagi 983-8536, Japan.
| | - Yojiro Ishikawa
- Division of Radiology, Tohoku Medical and Pharmaceutical University, Sendai, Miyagi 983-8536, Japan
| | - Satoshi Teramura
- Division of Radiology, Tohoku Medical and Pharmaceutical University, Sendai, Miyagi 983-8536, Japan
| | - Takayuki Yamada
- Division of Radiology, Tohoku Medical and Pharmaceutical University, Sendai, Miyagi 983-8536, Japan
| |
Collapse
|
2
|
Akino Y, Shiomi H, Tsujimoto T, Hamatani N, Hirata T, Oda M, Takeshita A, Shimamoto H, Ogawa K, Murakami S. Inverse planning optimization with lead block effectively suppresses dose to the mandible in high-dose-rate brachytherapy for tongue cancer. Jpn J Radiol 2023; 41:1290-1297. [PMID: 37273111 PMCID: PMC10613594 DOI: 10.1007/s11604-023-01451-w] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/22/2023] [Accepted: 05/14/2023] [Indexed: 06/06/2023]
Abstract
PURPOSE In this study, we developed in-house software to evaluate the effect of the lead block (LB)-inserted spacer on the mandibular dose in interstitial brachytherapy (ISBT) for tongue cancer. In addition, an inverse planning algorithm for LB attenuation was developed, and its performance in mandibular dose reduction was evaluated. METHODS Treatment plans of 30 patients with tongue cancer treated with ISBT were evaluated. The prescribed dose was 54 Gy/9 fractions. An in-house software was developed to calculate the dose distribution based on the American Association of Physicists in Medicine (AAPM) Task Group No.43 (TG-43) formalism. The mandibular dose was calculated with consideration of the LB attenuation. The attenuation coefficient of the lead was computed using the PHITS Monte Carlo simulation. The software further optimized the treatment plans using an attraction-repulsion model (ARM) to account for the LB attenuation. RESULTS Compared to the calculation in water, the D2 cc of the mandible changed by - 2.4 ± 2.3 Gy (range, - 8.6 to - 0.1 Gy) when the LB attenuation was considered. The ARM optimization with consideration of the LB resulted in a - 2.4 ± 2.4 Gy (range, - 8.2 to 0.0 Gy) change in mandibular D2 cc. CONCLUSIONS This study enabled the evaluation of the dose distribution with consideration of the LB attenuation. The ARM optimization with lead attenuation further reduced the mandibular dose.
Collapse
Affiliation(s)
- Yuichi Akino
- Department of Radiation Oncology, Osaka University Graduate School of Medicine, 2-2, Yamadaoka, Suita, Osaka, 565-0871, Japan.
- Department of Oral and Maxillofacial Radiology, Osaka University Graduate School of Dentistry, Suita, Osaka, Japan.
| | - Hiroya Shiomi
- Department of Radiation Oncology, Osaka University Graduate School of Medicine, 2-2, Yamadaoka, Suita, Osaka, 565-0871, Japan
- Department of Oral and Maxillofacial Radiology, Osaka University Graduate School of Dentistry, Suita, Osaka, Japan
| | - Tomomi Tsujimoto
- Department of Oral and Maxillofacial Radiology, Osaka University Graduate School of Dentistry, Suita, Osaka, Japan
| | - Noriaki Hamatani
- Department of Medical Physics, Osaka Heavy-Ion Therapy Center, Osaka, Japan
| | - Takero Hirata
- Department of Radiation Oncology, Osaka University Graduate School of Medicine, 2-2, Yamadaoka, Suita, Osaka, 565-0871, Japan
| | - Michio Oda
- Department of Medical Technology, Osaka University Hospital, Suita, Osaka, Japan
| | - Ami Takeshita
- Department of Oral and Maxillofacial Radiology, Osaka University Graduate School of Dentistry, Suita, Osaka, Japan
| | - Hiroaki Shimamoto
- Department of Oral and Maxillofacial Radiology, Osaka University Graduate School of Dentistry, Suita, Osaka, Japan
| | - Kazuhiko Ogawa
- Department of Radiation Oncology, Osaka University Graduate School of Medicine, 2-2, Yamadaoka, Suita, Osaka, 565-0871, Japan
| | - Shumei Murakami
- Department of Oral and Maxillofacial Radiology, Osaka University Graduate School of Dentistry, Suita, Osaka, Japan
| |
Collapse
|
3
|
He Y, Ma C, Hou J, Li X, Peng X, Wang H, Wang S, Liu L, Liu B, Tian L, Liu Z, Liu X, Xu X, Zhang D, Jiang C, Wang J, Yao Y, Zhu G, Bai Y, Wang S, Sun C, Li J, He S, Wang C, Zhang Z, Qiu W. Chinese expert group consensus on diagnosis and clinical management of osteoradionecrosis of the mandible. Int J Oral Maxillofac Surg 2020; 49:411-419. [PMID: 31353174 DOI: 10.1016/j.ijom.2019.06.015] [Citation(s) in RCA: 11] [Impact Index Per Article: 2.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/18/2019] [Revised: 03/23/2019] [Accepted: 06/05/2019] [Indexed: 02/08/2023]
Abstract
Osteoradionecrosis of the mandible (MORN) is one of the most devastating complications caused by radiation therapy in the head and neck region. It is characterized by infection and chronic necrosis of the mandible as the main manifestation. Clinically, MORN-related symptoms include swelling, pain, dysphagia, trismus, masticatory or speech disorders, refractory orocutaneous fistula, bone exposure, and even pathological fracture. MORN has become a challenging clinical problem for oral and maxillofacial surgeons to deal with, but thus far, this problem has not been solved due to the lack of widely accepted treatment algorithms or guidelines. Because of the nonexistence of standardized treatment criteria, most clinical treatment against MORN nowadays is largely based on controversial empirical understandings, while recommendations on post-therapeutic evaluations are scarce. Therefore, to further unify and standardize the diagnosis and treatment of MORN, to decrease the huge waste of medical resources, and ultimately, to improve the wellbeing of the patients, the Chinese Society of Oral and Maxillofacial Surgery (CSOMS) convened an expert panel specialized in MORN from 16 domestic medical colleges and affiliated hospitals to discuss the spectrum of diagnosis and and formulate treatment. In addition, consensus recommendations were also revised with a comprehensive literature review of the previous treatment experiences and research pearls. This 'expert consensus statement on diagnosis and clinical management of MORN' is for clinical reference.
Collapse
Affiliation(s)
- Y He
- Department of Oral & Maxillofacial - Head & Neck Oncology, 9th People's Hospital, Shanghai Jiao Tong University School of Medicine, Shanghai Key Laboratory of Stomatology, Shanghai, China.
| | - C Ma
- Department of Oral & Maxillofacial - Head & Neck Oncology, 9th People's Hospital, Shanghai Jiao Tong University School of Medicine, Shanghai Key Laboratory of Stomatology, Shanghai, China
| | - J Hou
- Department of Oral and Maxillofacial Surgery, Guanghua School of Stomatology, Hospital of Stomatology, Sun Yat-Sen University, Guangzhou, China
| | - X Li
- Department of Oral & Maxillofacial - Head & Neck Oncology, 9th People's Hospital, Shanghai Jiao Tong University School of Medicine, Shanghai Key Laboratory of Stomatology, Shanghai, China
| | - X Peng
- Department of Oral and Maxillofacial Surgery, Peking University School and Hospital of Stomatology, Beijing, China
| | - H Wang
- Stomatology Hospital Affiliated to School of Medicine, Zhejiang University, Zhejiang, China
| | - S Wang
- Salivary Gland Disease Center and Molecular Laboratory for Gene Therapy and Tooth Regeneration, School of Stomatology, Capital Medical University, Beijing, China
| | - L Liu
- Department of Oral and Maxillofacial Surgery, West China Hospital of Stomatology, Sichuan University, Chengdu, China
| | - B Liu
- The State Key Laboratory Breeding Base of Basic Science of Stomatology and Key Laboratory of Oral Biomedicine Ministry of Education, School and Hospital of Stomatology, Wuhan University, Wuhan, Hubei, China
| | - L Tian
- Department of Cranio-facial Trauma and Orthognathic Surgery, School of Stomatology, Fourth Military Medical University, Xi'an, China; The State Key Laboratory of Military Stomatology, School of Stomatology, Fourth Military Medical University, Xi'an, China
| | - Z Liu
- Department of Oral & Maxillofacial - Head & Neck Oncology, 9th People's Hospital, Shanghai Jiao Tong University School of Medicine, Shanghai Key Laboratory of Stomatology, Shanghai, China
| | - X Liu
- Department of Oral and Maxillofacial Surgery, Guanghua School of Stomatology, Hospital of Stomatology, Sun Yat-Sen University, Guangzhou, China
| | - X Xu
- Department of Oral and Maxillofacial Surgery, The Second Affiliated Hospital Zhejiang University School of Medicine, Zhejiang, Hangzhou, China
| | - D Zhang
- Department of Oral and Maxillofacial Surgery, Shandong Provincial Hospital Affiliated to Shandong University, Jinan, Shandong, China
| | - C Jiang
- Department of Oral and Maxillofacial Surgery, Xiangya Hospital, Central South University, Changsha, China
| | - J Wang
- Department of Head and Neck Surgery, Gansu Province Tumor Hospital, Lanzhou, China
| | - Y Yao
- Department of Radiotherapy, 9th People's Hospital, Shanghai Jiao Tong University School of Medicine, Shanghai, China
| | - G Zhu
- Department of Radiotherapy, Renji Hospital, Shanghai Jiao Tong University School of Medicine, Shanghai, China
| | - Y Bai
- Department of Radiotherapy, Renji Hospital, Shanghai Jiao Tong University School of Medicine, Shanghai, China
| | - S Wang
- Department of Radiation Oncology, Eye & ENT Hospital, Fudan University, Shanghai, China
| | - C Sun
- Department of Oromaxillofacial - Head and Neck Surgery, Department of Oral and Maxillofacial Surgery, School of Stomatology, China Medical University, Liaoning, China
| | - J Li
- Department of Oral and Maxillofacial Surgery, Sun Yat-Sen Memorial Hospital, Sun Yat-Sen University, Guangzhou, China
| | - S He
- The State Key Laboratory Breeding Base of Basic Science of Stomatology and Key Laboratory of Oral Biomedicine Ministry of Education, School and Hospital of Stomatology, Wuhan University, Wuhan, Hubei, China
| | - C Wang
- Department of Oral and Maxillofacial Surgery, Guanghua School of Stomatology, Hospital of Stomatology, Sun Yat-Sen University, Guangzhou, China
| | - Z Zhang
- Department of Oral & Maxillofacial - Head & Neck Oncology, 9th People's Hospital, Shanghai Jiao Tong University School of Medicine, Shanghai Key Laboratory of Stomatology, Shanghai, China
| | - W Qiu
- Department of Oral & Maxillofacial - Head & Neck Oncology, 9th People's Hospital, Shanghai Jiao Tong University School of Medicine, Shanghai Key Laboratory of Stomatology, Shanghai, China
| |
Collapse
|
4
|
A new implant device to prevent edema-associated underdosage in high-dose-rate interstitial brachytherapy of mobile tongue cancer. J Contemp Brachytherapy 2020; 11:573-578. [PMID: 31969916 PMCID: PMC6964338 DOI: 10.5114/jcb.2019.91225] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/26/2019] [Accepted: 10/24/2019] [Indexed: 11/30/2022] Open
Abstract
Purpose Tongue edema is a potential cause of treatment target underdosage in high-dose-rate interstitial brachytherapy (HDR-ISBT) of mobile tongue cancer. To prevent such edema-associated alteration of dosimetry, we developed a special silicon device. In this report we communicate our initial experience with two mobile tongue cancer patients whom we treated using this new device. Material and methods The device consists of silicone tubes with a fixed width and scalable length depending on tongue size. These tubes are lined and fixed like a palisade, allowing the device to be used also as a template. The device is placed next to the lateral border of the tongue and on the floor of the mouth. In addition, a vinyl template can be placed on the dorsal tongue surface with both devices combined for implantation guidance. Between June and August 2012, two patients with locally confined tongue cancer were treated. Results Between June and August 2012, two mobile tongue cancer patients classified as cT2N0M0 were treated with HDR-ISBT using the silicone device. They underwent ISBT as monotherapy with fractional doses of 6.0 Gy up to a total physical dose of 54.0 Gy. The D90 (CTV) values of both patients were 6.3 Gy and 6.6 Gy and the D2cc (mandible) values were 3.4 Gy and 2.6 Gy, respectively. At present, both patients remain without local disease recurrence at 60 and 56 months after ISBT, respectively. Conclusions The described silicone device has the potential to prevent underdosage to the treatment target related to tongue edema. It has been shown to be safe and easy to implement.
Collapse
|
5
|
Dalwadi S, Suri A, Kamat A, Butler EB, Farach AM. Laparoscopic Allograft Spacer Placement to Minimize Bowel Dose During Re-irradiation with Interstitial Brachytherapy. Cureus 2019; 11:e5958. [PMID: 31799096 PMCID: PMC6863581 DOI: 10.7759/cureus.5958] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/05/2022] Open
Abstract
In primary or re-irradiation of gynecologic malignancies, achieving optimal dosimetry with adjacent normal tissue becomes challenging. Surgical spacers are tissue-equivalent materials placed within the patient to protect organs at risk from long-term radiation effects and are commonly used in prostate cancer. We report the use of an allograft mesh to protect adhesed bowel from high-dose radiation for definitive treatment of recurrent endometrial cancer. An 88-year-old female was diagnosed with International Federation of Gynecology and Obstetrics (FIGO) stage II endometrial cancer after she developed urinary frequency, hesitancy, and hematuria. She underwent neoadjuvant chemoradiation, followed by laparoscopic hysterectomy with bilateral salpingo-oophorectomy and adjuvant vaginal cuff brachytherapy. She developed 1.8 cm bilateral vaginal cuff recurrence and was dispositioned for interstitial brachytherapy. An allograft mesh spacer was placed laparoscopically before repeat, high dose rate brachytherapy to protect nearby structures. Dose-escalation was achieved without compromising normal tissue constraints. The patient tolerated the procedure without evidence of long-term toxicity at one year. Multidisciplinary discussion may help identify patients who would benefit from spacer placement before select dose-escalated radiation therapy. Laparoscopic allograft mesh is one of many types of surgical spacers available for such patients.
Collapse
Affiliation(s)
| | - Anuj Suri
- Obstetrics and Gynecology, Houston Methodist Hospital, Houston, USA
| | - Aparna Kamat
- Obstetrics and Gynecology, Houston Methodist Hospital, Houston, USA
| | - E Brian Butler
- Radiation Oncology, Houston Methodist Hospital, Houston, USA
| | - Andrew M Farach
- Radiation Oncology, Houston Methodist Hospital, Houston, USA
| |
Collapse
|
6
|
Monzen H, Tamura M, Kijima K, Otsuka M, Matsumoto K, Wakabayashi K, Choi MG, Yoon DK, Doi H, Akiyama H, Nishimura Y. Estimation of radiation shielding ability in electron therapy and brachytherapy with real time variable shape tungsten rubber. Phys Med 2019; 66:29-35. [PMID: 31550531 DOI: 10.1016/j.ejmp.2019.09.233] [Citation(s) in RCA: 12] [Impact Index Per Article: 2.4] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 08/06/2019] [Revised: 08/28/2019] [Accepted: 09/14/2019] [Indexed: 11/16/2022] Open
Abstract
PURPOSE To clarify the physical characteristics of a newly developed real time variable shape rubber containing tungsten (STR) with changes in heat and estimate its shielding abilities against electron beams and γ-rays from 192Ir. METHODS Dynamic mechanical analysis for the STR (density = 7.3 g/cm3) was conducted at a frequency of 1.0 Hz in the temperature range of -60 °C to 60 °C. We evaluated tanδ, defined as the ratio (E″/E') between the storage modulus (E') and loss modulus (E″). The transmission rates were measured against 6- and 12-MeV electron beams and the percentage depth dose and lateral dose profile were compared with low-melting alloy (LMA). For the shielding rate of 192Ir against γ-rays, measurement data and Monte Carlo simulation data were obtained with STR thickness ranging from 1.0 mm to 16.0 mm. RESULTS At 36 °C, the tanδ value was 0.520, while at 60 °C, this value was 1.016. For 6- and 12-MeV electron beams, the transmission rates decreased with increasing STR thickness and reached plateaus at approximately 1.0% and 4.0% with STR thickness of >7.0 and >12.0 mm, respectively. The dose distributions were almost equal to those for LMA. Against γ-rays, the thickness of STR that obtained a 50% attenuation rate for 192Ir was 5.804 mm. The Monte Carlo calculation results were 2.6% higher on average than the measurement results. CONCLUSION The STR can be changed shape in real time at 60 °C and maintains its shape at body temperatures. It has adequate shielding abilities against megavoltage electron beams and γ-rays from 192Ir.
Collapse
Affiliation(s)
- Hajime Monzen
- Department of Medical Physics, Graduate School of Medical Sciences, Kindai University, Osaka-Sayama, Osaka 589-8511, Japan.
| | - Mikoto Tamura
- Department of Medical Physics, Graduate School of Medical Sciences, Kindai University, Osaka-Sayama, Osaka 589-8511, Japan
| | - Kenta Kijima
- Department of Medical Physics, Graduate School of Medical Sciences, Kindai University, Osaka-Sayama, Osaka 589-8511, Japan
| | - Masakazu Otsuka
- Department of Medical Physics, Graduate School of Medical Sciences, Kindai University, Osaka-Sayama, Osaka 589-8511, Japan; Department of Central Radiology, Kindai University Hospital, Osaka-Sayama, Osaka 589-8511, Japan
| | - Kenji Matsumoto
- Department of Medical Physics, Graduate School of Medical Sciences, Kindai University, Osaka-Sayama, Osaka 589-8511, Japan; Department of Central Radiology, Kindai University Hospital, Osaka-Sayama, Osaka 589-8511, Japan
| | - Kazuki Wakabayashi
- Department of Medical Physics, Graduate School of Medical Sciences, Kindai University, Osaka-Sayama, Osaka 589-8511, Japan
| | - Min-Geon Choi
- Department of Medical Physics, Graduate School of Medical Sciences, Kindai University, Osaka-Sayama, Osaka 589-8511, Japan; Department of Biomedical Engineering and Research Institute of Biomedical Engineering, College of Medicine, Catholic University of Korea, Seoul 06591, South Korea
| | - Do-Kun Yoon
- Department of Biomedical Engineering and Research Institute of Biomedical Engineering, College of Medicine, Catholic University of Korea, Seoul 06591, South Korea
| | - Hiroshi Doi
- Department of Radiation Oncology, Faculty of Medicine, Kindai University, 377-2 Ohno-higashi, Osaka-Sayama, Osaka 589-8511, Japan
| | - Hironori Akiyama
- Department of Oral Radiology, Osaka Dental University, 1-5-17 Otemae Chuo-ku, Osaka 540-0008, Japan
| | - Yasumasa Nishimura
- Department of Radiation Oncology, Faculty of Medicine, Kindai University, 377-2 Ohno-higashi, Osaka-Sayama, Osaka 589-8511, Japan
| |
Collapse
|
7
|
Ikawa H, Koto M, Ebner DK, Hayashi K, Takagi R, Tonogi M, Nomura T, Tsuji H, Kamada T. The Efficacy of a Custom-Made Mouthpiece With Spacer to Reduce Osteoradionecrosis in Carbon-Ion Radiation Therapy for Tongue-Base Tumor. Adv Radiat Oncol 2018; 4:15-19. [PMID: 30706004 PMCID: PMC6349587 DOI: 10.1016/j.adro.2018.08.016] [Citation(s) in RCA: 9] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/26/2018] [Revised: 08/14/2018] [Accepted: 08/14/2018] [Indexed: 11/16/2022] Open
Affiliation(s)
- Hiroaki Ikawa
- Hospital of the National Institute of Radiological Sciences, National Institutes for Quantum and Radiological Science and Technology, Chiba, Japan
| | - Masashi Koto
- Hospital of the National Institute of Radiological Sciences, National Institutes for Quantum and Radiological Science and Technology, Chiba, Japan
| | - Daniel K Ebner
- Hospital of the National Institute of Radiological Sciences, National Institutes for Quantum and Radiological Science and Technology, Chiba, Japan.,Brown University Alpert Medical School, Providence, Rhode Island
| | - Kazuhiko Hayashi
- Hospital of the National Institute of Radiological Sciences, National Institutes for Quantum and Radiological Science and Technology, Chiba, Japan
| | - Ryo Takagi
- Hospital of the National Institute of Radiological Sciences, National Institutes for Quantum and Radiological Science and Technology, Chiba, Japan
| | - Morio Tonogi
- Department of Oral and Maxillofacial Surgery, Nihon University School of Dentistry, Tokyo, Japan
| | - Takeshi Nomura
- Department of Oral Medicine, Oral and Maxillofacial Surgery, Tokyo Dental College, Tokyo, Japan
| | - Hiroshi Tsuji
- Hospital of the National Institute of Radiological Sciences, National Institutes for Quantum and Radiological Science and Technology, Chiba, Japan
| | - Tadashi Kamada
- Hospital of the National Institute of Radiological Sciences, National Institutes for Quantum and Radiological Science and Technology, Chiba, Japan
| |
Collapse
|
8
|
|
9
|
Utility of intraoral stents in external beam radiotherapy for head and neck cancer. Rep Pract Oncol Radiother 2017; 22:310-318. [PMID: 28515675 DOI: 10.1016/j.rpor.2017.03.002] [Citation(s) in RCA: 20] [Impact Index Per Article: 2.9] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/22/2016] [Revised: 01/25/2017] [Accepted: 03/16/2017] [Indexed: 11/21/2022] Open
Abstract
AIM This study aimed to assess the utility and stability of intraoral stent during intensity-modulated radiation therapy (IMRT). BACKGROUND The benefits of intraoral stents in radiotherapy are unclear. MATERIALS AND METHODS We analyzed 386 setup errors in 12 patients who received IMRT for head and neck cancers without intraoral stents (intraoral stent [-]) and 183 setup errors in 6 patients who received IMRT with intraoral stents (intraoral stent [+]). All patients were matched according to the immobilization method (masks and boards). Setup errors were measured as the distance from the initial setup based on the marking on the skin and mask to the corrected position based on bone matching on cone beam computed tomography. RESULTS The mean interfractional setup errors in the right-left, craniocaudal, anterior-posterior (AP), and three-dimensional (3D) directions were -0.33, 0.08, -0.25, and 2.75 mm in the intraoral stent (-) group and -0.37, 0.24, -0.63, and 2.42 mm in the intraoral stent (+) group, respectively (P = 0.50, 0.65, 0.01, and 0.02, respectively). The systematic errors for the same directions were 0.89, 1.46, 1.15, and 0.88 mm in the intraoral stent (-) group and 0.62, 1.69, 0.68, and 0.56 mm in the intraoral stents (+) group, respectively. The random errors were 1.43, 1.43, 1.44, and 1.22 mm in the intraoral stent (-) group and 1.06, 1.11, 1.05, and 0.92 mm in the intraoral stents (+) group, respectively. CONCLUSION Setup errors can be significantly reduced in the AP and 3D-directions by using intraoral stents.
Collapse
|