1
|
Wang F, Sun YN, Zhang BT, Yang Q, He AD, Xu WY, Liu J, Liu MX, Li XH, Yu YQ, Zhu J. Value of fractional-order calculus (FROC) model diffusion-weighted imaging combined with simultaneous multi-slice (SMS) acceleration technology for evaluating benign and malignant breast lesions. BMC Med Imaging 2024; 24:190. [PMID: 39075336 DOI: 10.1186/s12880-024-01368-4] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/19/2024] [Accepted: 07/16/2024] [Indexed: 07/31/2024] Open
Abstract
BACKGROUND This study explores the diagnostic value of combining fractional-order calculus (FROC) diffusion-weighted model with simultaneous multi-slice (SMS) acceleration technology in distinguishing benign and malignant breast lesions. METHODS 178 lesions (73 benign, 105 malignant) underwent magnetic resonance imaging with diffusion-weighted imaging using multiple b-values (14 b-values, highest 3000 s/mm2). Independent samples t-test or Mann-Whitney U test compared image quality scores, FROC model parameters (D,, ), and ADC values between two groups. Multivariate logistic regression analysis identified independent variables and constructed nomograms. Model discrimination ability was assessed with receiver operating characteristic (ROC) curve and calibration chart. Spearman correlation analysis and Bland-Altman plot evaluated parameter correlation and consistency. RESULTS Malignant lesions exhibited lower D, and ADC values than benign lesions (P < 0.05), with higher values (P < 0.05). In SSEPI-DWI and SMS-SSEPI-DWI sequences, the AUC and diagnostic accuracy of D value are maximal, with D value demonstrating the highest diagnostic sensitivity, while value exhibits the highest specificity. The D and combined model had the highest AUC and accuracy. D and ADC values showed high correlation between sequences, and moderate. Bland-Altman plot demonstrated unbiased parameter values. CONCLUSION SMS-SSEPI-DWI FROC model provides good image quality and lesion characteristic values within an acceptable time. It shows consistent diagnostic performance compared to SSEPI-DWI, particularly in D and values, and significantly reduces scanning time.
Collapse
Affiliation(s)
- Fei Wang
- Department of Radiology, The First Affiliated Hospital of Anhui Medical University, No.218, Jixi Road, Hefei, 230032, China
- Department of Radiology, Anqing Municipal Hospital, No.352, Renmin Road, Anqing, 246003, China
| | - Yi-Nan Sun
- Department of Radiology, Anqing Municipal Hospital, No.352, Renmin Road, Anqing, 246003, China
| | - Bao-Ti Zhang
- Department of Radiology, Anqing Municipal Hospital, No.352, Renmin Road, Anqing, 246003, China
| | - Qing Yang
- Department of Radiology, Anqing Municipal Hospital, No.352, Renmin Road, Anqing, 246003, China
| | - An-Dong He
- Department of Radiology, Anqing Municipal Hospital, No.352, Renmin Road, Anqing, 246003, China
| | - Wang-Yan Xu
- Department of Radiology, Anqing Municipal Hospital, No.352, Renmin Road, Anqing, 246003, China
| | - Jun Liu
- Department of Radiology, Anqing Municipal Hospital, No.352, Renmin Road, Anqing, 246003, China
| | - Meng-Xiao Liu
- MR Research & Marketing Department, Siemens Healthineers Co., Ltd, No.278, Zhouzugong Road, Shanghai, 201318, China
| | - Xiao-Hu Li
- Department of Radiology, The First Affiliated Hospital of Anhui Medical University, No.218, Jixi Road, Hefei, 230032, China
| | - Yong-Qiang Yu
- Department of Radiology, The First Affiliated Hospital of Anhui Medical University, No.218, Jixi Road, Hefei, 230032, China.
| | - Juan Zhu
- Department of Radiology, Anqing Municipal Hospital, No.352, Renmin Road, Anqing, 246003, China.
| |
Collapse
|
2
|
Pistel M, Brock L, Laun FB, Erber R, Weiland E, Uder M, Wenkel E, Ohlmeyer S, Bickelhaupt S. Stability of Radiomic Features against Variations in Lesion Segmentations Computed on Apparent Diffusion Coefficient Maps of Breast Lesions. Diagnostics (Basel) 2024; 14:1427. [PMID: 39001317 PMCID: PMC11241112 DOI: 10.3390/diagnostics14131427] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/18/2024] [Revised: 06/18/2024] [Accepted: 06/24/2024] [Indexed: 07/16/2024] Open
Abstract
Diffusion-weighted imaging (DWI) combined with radiomics can aid in the differentiation of breast lesions. Segmentation characteristics, however, might influence radiomic features. To evaluate feature stability, we implemented a standardized pipeline featuring shifts and shape variations of the underlying segmentations. A total of 103 patients were retrospectively included in this IRB-approved study after multiparametric diagnostic breast 3T MRI with a spin-echo diffusion-weighted sequence with echoplanar readout (b-values: 50, 750 and 1500 s/mm2). Lesion segmentations underwent shifts and shape variations, with >100 radiomic features extracted from apparent diffusion coefficient (ADC) maps for each variation. These features were then compared and ranked based on their stability, measured by the Overall Concordance Correlation Coefficient (OCCC) and Dynamic Range (DR). Results showed variation in feature robustness to segmentation changes. The most stable features, excluding shape-related features, were FO (Mean, Median, RootMeanSquared), GLDM (DependenceNonUniformity), GLRLM (RunLengthNonUniformity), and GLSZM (SizeZoneNonUniformity), which all had OCCC and DR > 0.95 for both shifting and resizing the segmentation. Perimeter, MajorAxisLength, MaximumDiameter, PixelSurface, MeshSurface, and MinorAxisLength were the most stable features in the Shape category with OCCC and DR > 0.95 for resizing. Considering the variability in radiomic feature stability against segmentation variations is relevant when interpreting radiomic analysis of breast DWI data.
Collapse
Affiliation(s)
- Mona Pistel
- Institute of Radiology, University Hospital Erlangen, Friedrich-Alexander-Universität Erlangen-Nürnberg (FAU), 91054 Erlangen, Germany
- Siemens Healthineers AG, 91052 Erlangen, Germany
| | - Luise Brock
- Institute of Radiology, University Hospital Erlangen, Friedrich-Alexander-Universität Erlangen-Nürnberg (FAU), 91054 Erlangen, Germany
| | - Frederik Bernd Laun
- Institute of Radiology, University Hospital Erlangen, Friedrich-Alexander-Universität Erlangen-Nürnberg (FAU), 91054 Erlangen, Germany
| | - Ramona Erber
- Institute of Pathology, Friedrich-Alexander-Universität Erlangen-Nürnberg (FAU), 91054 Erlangen, Germany
| | - Elisabeth Weiland
- MR Application Predevelopment, Siemens Healthineers AG, 91052 Erlangen, Germany
| | - Michael Uder
- Institute of Radiology, University Hospital Erlangen, Friedrich-Alexander-Universität Erlangen-Nürnberg (FAU), 91054 Erlangen, Germany
| | - Evelyn Wenkel
- Institute of Radiology, University Hospital Erlangen, Friedrich-Alexander-Universität Erlangen-Nürnberg (FAU), 91054 Erlangen, Germany
- Radiologie München, 80331 München, Germany
| | - Sabine Ohlmeyer
- Institute of Radiology, University Hospital Erlangen, Friedrich-Alexander-Universität Erlangen-Nürnberg (FAU), 91054 Erlangen, Germany
| | - Sebastian Bickelhaupt
- Institute of Radiology, University Hospital Erlangen, Friedrich-Alexander-Universität Erlangen-Nürnberg (FAU), 91054 Erlangen, Germany
| |
Collapse
|
3
|
Tang C, Li F, He L, Hu Q, Qin Y, Yan X, Ai T. Comparison of continuous-time random walk and fractional order calculus models in characterizing breast lesions using histogram analysis. Magn Reson Imaging 2024; 108:47-58. [PMID: 38307375 DOI: 10.1016/j.mri.2024.01.012] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/11/2023] [Revised: 11/11/2023] [Accepted: 01/22/2024] [Indexed: 02/04/2024]
Abstract
OBJECTIVE To compare the diagnostic performance of different mathematical models for DWI and explore whether parameters reflecting spatial and temporal heterogeneity can demonstrate better diagnostic accuracy than the diffusion coefficient parameter in distinguishing benign and malignant breast lesions, using whole-tumor histogram analysis. METHODS This retrospective study was approved by the institutional ethics committee and included 104 malignant and 42 benign cases. All patients underwent breast magnetic resonance imaging (MRI) with a 3.0 T MR scanner using the simultaneous multi-slice (SMS) readout-segment ed echo-planar imaging (rs-EPI). Histogram metrics of Mono- apparent diffusion coefficient (ADC), CTRW, and FROC-derived parameters were compared between benign and malignant breast lesions, and the diagnostic performance of each diffusion parameter was evaluated. Statistical analysis was performed using Mann-Whitney U test and receiver operating characteristic (ROC) curve. RESULTS The DFROC-median exhibited the highest AUC for distinguishing benign and malignant breast lesions (AUC = 0.965). The temporal heterogeneity parameter αCTRW-median generated a statistically higher AUC compared to the spatial heterogeneity parameter βCTRW-median (AUC = 0.850 and 0.741, respectively; p = 0.047). Finally, the combination of median values of CTRW parameters displayed a slightly higher AUC than that of FROC parameters, with no significant difference however (AUC = 0.971 and 0.965, respectively; p = 0.172). CONCLUSIONS The diffusion coefficient parameter exhibited superior diagnostic performance in distinguishing breast lesions when compared to the temporal and spatial heterogeneity parameters.
Collapse
Affiliation(s)
- Caili Tang
- Department of Radiology, Tongji Hospital, Tongji Medical College, Huazhong University of Science and Technology, Wuhan 430030, China
| | - Feng Li
- Department of Radiology, Xiangyang Central Hospital, Affiliated Hospital of Hubei University of Arts and Science, Xiangyang, Hubei 441021, China
| | - Litong He
- Department of Radiology, Tongji Hospital, Tongji Medical College, Huazhong University of Science and Technology, Wuhan 430030, China
| | - Qilan Hu
- Department of Radiology, Tongji Hospital, Tongji Medical College, Huazhong University of Science and Technology, Wuhan 430030, China
| | - Yanjin Qin
- Department of Radiology, Tongji Hospital, Tongji Medical College, Huazhong University of Science and Technology, Wuhan 430030, China
| | - Xu Yan
- MR Research Collaboration Team, Siemens Healthineers Ltd, 278, Zhouzhu Road, Nanhui, Shanghai 201318, China
| | - Tao Ai
- Department of Radiology, Tongji Hospital, Tongji Medical College, Huazhong University of Science and Technology, Wuhan 430030, China.
| |
Collapse
|
4
|
Skwierawska D, Laun FB, Wenkel E, Kapsner LA, Janka R, Uder M, Ohlmeyer S, Bickelhaupt S. Diffusion-Weighted Imaging for Skin Pathologies of the Breast-A Feasibility Study. Diagnostics (Basel) 2024; 14:934. [PMID: 38732348 PMCID: PMC11083106 DOI: 10.3390/diagnostics14090934] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/07/2024] [Revised: 04/19/2024] [Accepted: 04/24/2024] [Indexed: 05/13/2024] Open
Abstract
Several breast pathologies can affect the skin, and clinical pathways might differ significantly depending on the underlying diagnosis. This study investigates the feasibility of using diffusion-weighted imaging (DWI) to differentiate skin pathologies in breast MRIs. This retrospective study included 88 female patients who underwent diagnostic breast MRI (1.5 or 3T), including DWI. Skin areas were manually segmented, and the apparent diffusion coefficients (ADCs) were compared between different pathologies: inflammatory breast cancer (IBC; n = 5), benign skin inflammation (BSI; n = 11), Paget's disease (PD; n = 3), and skin-involved breast cancer (SIBC; n = 11). Fifty-eight women had healthy skin (H; n = 58). The SIBC group had a significantly lower mean ADC than the BSI and IBC groups. These differences persisted for the first-order features of the ADC (mean, median, maximum, and minimum) only between the SIBC and BSI groups. The mean ADC did not differ significantly between the BSI and IBC groups. Quantitative DWI assessments demonstrated differences between various skin-affecting pathologies, but did not distinguish clearly between all of them. More extensive studies are needed to assess the utility of quantitative DWI in supplementing the diagnostic assessment of skin pathologies in breast imaging.
Collapse
Affiliation(s)
- Dominika Skwierawska
- Institute of Radiology, Universitätsklinikum Erlangen, Friedrich-Alexander-Universität Erlangen-Nürnberg (FAU), Maximiliansplatz 3, 91054 Erlangen, Germany
| | - Frederik B. Laun
- Institute of Radiology, Universitätsklinikum Erlangen, Friedrich-Alexander-Universität Erlangen-Nürnberg (FAU), Maximiliansplatz 3, 91054 Erlangen, Germany
| | - Evelyn Wenkel
- Radiologie München, Burgstraße 7, 80331 München, Germany
- Medical Faculty, Friedrich-Alexander-Universität Erlangen-Nürnberg (FAU), 91054 Erlangen, Germany
| | - Lorenz A. Kapsner
- Institute of Radiology, Universitätsklinikum Erlangen, Friedrich-Alexander-Universität Erlangen-Nürnberg (FAU), Maximiliansplatz 3, 91054 Erlangen, Germany
- Chair of Medical Informatics, Friedrich-Alexander-Universität Erlangen-Nürnberg (FAU), Wetterkreuz 15, 91058 Erlangen-Tennenlohe, Germany
| | - Rolf Janka
- Institute of Radiology, Universitätsklinikum Erlangen, Friedrich-Alexander-Universität Erlangen-Nürnberg (FAU), Maximiliansplatz 3, 91054 Erlangen, Germany
| | - Michael Uder
- Institute of Radiology, Universitätsklinikum Erlangen, Friedrich-Alexander-Universität Erlangen-Nürnberg (FAU), Maximiliansplatz 3, 91054 Erlangen, Germany
| | - Sabine Ohlmeyer
- Institute of Radiology, Universitätsklinikum Erlangen, Friedrich-Alexander-Universität Erlangen-Nürnberg (FAU), Maximiliansplatz 3, 91054 Erlangen, Germany
| | - Sebastian Bickelhaupt
- Institute of Radiology, Universitätsklinikum Erlangen, Friedrich-Alexander-Universität Erlangen-Nürnberg (FAU), Maximiliansplatz 3, 91054 Erlangen, Germany
| |
Collapse
|
5
|
Mao C, Hu L, Jiang W, Qiu Y, Yang Z, Liu Y, Wang M, Wang D, Su Y, Lin J, Yan X, Cai Z, Zhang X, Shen J. Discrimination between human epidermal growth factor receptor 2 (HER2)-low-expressing and HER2-overexpressing breast cancers: a comparative study of four MRI diffusion models. Eur Radiol 2024; 34:2546-2559. [PMID: 37672055 DOI: 10.1007/s00330-023-10198-x] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/05/2023] [Revised: 06/13/2023] [Accepted: 07/08/2023] [Indexed: 09/07/2023]
Abstract
OBJECTIVES To determine the value of conventional DWI, continuous-time random walk (CTRW), fractional order calculus (FROC), and stretched exponential model (SEM) in discriminating human epidermal growth factor receptor 2 (HER2) status of breast cancer (BC). METHODS This prospective study included 158 women who underwent DWI, CTRW, FROC, and SEM and were pathologically categorized into the HER2-zero-expressing group (n = 10), HER2-low-expressing group (n = 86), and HER2-overexpressing group (n = 62). Nine diffusion parameters, namely ADC, αCTRW, βCTRW, DCTRW, βFROC, DFROC, μFROC, αSEM, and DDCSEM of the primary tumor, were derived from four diffusion models. These diffusion metrics and clinicopathologic features were compared between groups. Logistic regression was used to determine the optimal diffusion metrics and clinicopathologic variables for classifying the HER2-expressing statuses. Receiver operating characteristic (ROC) curves were used to evaluate their discriminative ability. RESULTS The estrogen receptor (ER) status, progesterone receptor (PR) status, and tumor size differed between HER2-low-expressing and HER2-overexpressing groups (p < 0.001 to p = 0.009). The αCTRW, DCTRW, βFROC, DFROC, μFROC, αSEM, and DDCSEM were significantly lower in HER2-low-expressing BCs than those in HER2-overexpressing BCs (p < 0.001 to p = 0.01). Further multivariable logistic regression analysis showed that the αCTRW was the single best discriminative metric, with an area under the curve (AUC) being higher than that of ADC (0.802 vs. 0.610, p < 0.05); the addition of ER status, PR status, and tumor size to the αCTRW improved the AUC to 0.877. CONCLUSIONS The αCTRW could help discriminate the HER2-low-expressing and HER2-overexpressing BCs. CLINICAL RELEVANCE STATEMENT Human epidermal growth factor receptor 2 (HER2)-low-expressing breast cancer (BC) might also benefit from the HER2-targeted therapy. Prediction of HER2-low-expressing BC or HER2-overexpressing BC is crucial for appropriate management. Advanced continuous-time random walk diffusion MRI offers a solution to this clinical issue. KEY POINTS • Human epidermal receptor 2 (HER2)-low-expressing BC had lower αCTRW, DCTRW, βFROC, DFROC, μFROC, αSEM, and DDCSEM values compared with HER2-overexpressing breast cancer. • The αCTRW was the single best diffusion metric (AUC = 0.802) for discrimination between the HER2-low-expressing and HER2-overexpressing breast cancers. • The addition of αCTRW to the clinicopathologic features (estrogen receptor status, progesterone receptor status, and tumor size) further improved the discriminative ability.
Collapse
Affiliation(s)
- Chunping Mao
- Department of Radiology, Sun Yat-Sen Memorial Hospital, Sun Yat-Sen University, No. 107 Yanjiang Road West, Guangzhou, 510120, Guangdong, China
- Guangdong Provincial Key Laboratory of Malignant Tumor Epigenetics and Gene Regulation, Medical Research Center, Sun Yat-Sen Memorial Hospital, Sun Yat-Sen University, Guangzhou, Guangdong, China
| | - Lanxin Hu
- Department of Radiology, Sun Yat-Sen Memorial Hospital, Sun Yat-Sen University, No. 107 Yanjiang Road West, Guangzhou, 510120, Guangdong, China
- Guangdong Provincial Key Laboratory of Malignant Tumor Epigenetics and Gene Regulation, Medical Research Center, Sun Yat-Sen Memorial Hospital, Sun Yat-Sen University, Guangzhou, Guangdong, China
| | - Wei Jiang
- Department of Radiology, Sun Yat-Sen Memorial Hospital, Sun Yat-Sen University, No. 107 Yanjiang Road West, Guangzhou, 510120, Guangdong, China
- Guangdong Provincial Key Laboratory of Malignant Tumor Epigenetics and Gene Regulation, Medical Research Center, Sun Yat-Sen Memorial Hospital, Sun Yat-Sen University, Guangzhou, Guangdong, China
| | - Ya Qiu
- Department of Radiology, Sun Yat-Sen Memorial Hospital, Sun Yat-Sen University, No. 107 Yanjiang Road West, Guangzhou, 510120, Guangdong, China
- Guangdong Provincial Key Laboratory of Malignant Tumor Epigenetics and Gene Regulation, Medical Research Center, Sun Yat-Sen Memorial Hospital, Sun Yat-Sen University, Guangzhou, Guangdong, China
| | - Zehong Yang
- Department of Radiology, Sun Yat-Sen Memorial Hospital, Sun Yat-Sen University, No. 107 Yanjiang Road West, Guangzhou, 510120, Guangdong, China
- Guangdong Provincial Key Laboratory of Malignant Tumor Epigenetics and Gene Regulation, Medical Research Center, Sun Yat-Sen Memorial Hospital, Sun Yat-Sen University, Guangzhou, Guangdong, China
| | - Yeqing Liu
- Guangdong Provincial Key Laboratory of Malignant Tumor Epigenetics and Gene Regulation, Medical Research Center, Sun Yat-Sen Memorial Hospital, Sun Yat-Sen University, Guangzhou, Guangdong, China
- Department of Pathology, Sun Yat-Sen Memorial Hospital, Sun Yat-Sen University, Guangzhou, Guangdong, China
| | - Mengzhu Wang
- MR Scientific Marketing, Siemens Healthcare, Guangzhou, Guangdong, China
| | - Dongye Wang
- Department of Radiology, Sun Yat-Sen Memorial Hospital, Sun Yat-Sen University, No. 107 Yanjiang Road West, Guangzhou, 510120, Guangdong, China
- Guangdong Provincial Key Laboratory of Malignant Tumor Epigenetics and Gene Regulation, Medical Research Center, Sun Yat-Sen Memorial Hospital, Sun Yat-Sen University, Guangzhou, Guangdong, China
| | - Yun Su
- Department of Radiology, Sun Yat-Sen Memorial Hospital, Sun Yat-Sen University, No. 107 Yanjiang Road West, Guangzhou, 510120, Guangdong, China
- Guangdong Provincial Key Laboratory of Malignant Tumor Epigenetics and Gene Regulation, Medical Research Center, Sun Yat-Sen Memorial Hospital, Sun Yat-Sen University, Guangzhou, Guangdong, China
| | - Jinru Lin
- Department of Radiology, Sun Yat-Sen Memorial Hospital, Sun Yat-Sen University, No. 107 Yanjiang Road West, Guangzhou, 510120, Guangdong, China
- Guangdong Provincial Key Laboratory of Malignant Tumor Epigenetics and Gene Regulation, Medical Research Center, Sun Yat-Sen Memorial Hospital, Sun Yat-Sen University, Guangzhou, Guangdong, China
| | - Xu Yan
- MR Scientific Marketing, Siemens Healthcare, Guangzhou, Guangdong, China
| | - Zhaoxi Cai
- Department of Radiology, Sun Yat-Sen Memorial Hospital, Sun Yat-Sen University, No. 107 Yanjiang Road West, Guangzhou, 510120, Guangdong, China
- Guangdong Provincial Key Laboratory of Malignant Tumor Epigenetics and Gene Regulation, Medical Research Center, Sun Yat-Sen Memorial Hospital, Sun Yat-Sen University, Guangzhou, Guangdong, China
| | - Xiang Zhang
- Department of Radiology, Sun Yat-Sen Memorial Hospital, Sun Yat-Sen University, No. 107 Yanjiang Road West, Guangzhou, 510120, Guangdong, China.
- Guangdong Provincial Key Laboratory of Malignant Tumor Epigenetics and Gene Regulation, Medical Research Center, Sun Yat-Sen Memorial Hospital, Sun Yat-Sen University, Guangzhou, Guangdong, China.
| | - Jun Shen
- Department of Radiology, Sun Yat-Sen Memorial Hospital, Sun Yat-Sen University, No. 107 Yanjiang Road West, Guangzhou, 510120, Guangdong, China.
- Guangdong Provincial Key Laboratory of Malignant Tumor Epigenetics and Gene Regulation, Medical Research Center, Sun Yat-Sen Memorial Hospital, Sun Yat-Sen University, Guangzhou, Guangdong, China.
| |
Collapse
|
6
|
Oh KE, Vasandani N, Anwar A. Radiomics to Differentiate Malignant and Benign Breast Lesions: A Systematic Review and Diagnostic Test Accuracy Meta-Analysis. Cureus 2023; 15:e49015. [PMID: 38024014 PMCID: PMC10657146 DOI: 10.7759/cureus.49015] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Accepted: 11/18/2023] [Indexed: 12/01/2023] Open
Abstract
Breast cancer is a prevalent global health concern, necessitating accurate diagnostic tools for effective management. Diagnostic imaging plays a pivotal role in breast cancer diagnosis, staging, treatment planning, and outcome evaluation. Radiomics is an emerging field of study in medical imaging that contains a broad set of computational methods to extract quantitative features from radiographic images. This can be utilized to guide diagnosis, treatment response, and prognosis in clinical settings. A systematic review was performed in concordance with Preferred Reporting Items for Systematic Reviews and Meta-Analyses (PRISMA) guidelines and the Cochrane Handbook for Systematic Reviews of Diagnostic Test Accuracy. Quality was assessed using the radiomics quality score. Diagnostic sensitivity and specificity of radiomics analysis, with 95% confidence intervals (CIs), were included for meta-analysis. The area under the curve analysis was recorded. An extensive statistical analysis was performed following the Cochrane guidelines. Statistical significance was determined if p-values were less than 0.05. Statistical analyses were conducted using Review Manager (RevMan), Version 5.4.1. A total of 31 manuscripts involving 8,773 patients were included, with 17 contributing to the meta-analysis. The cohort comprised 56.2% malignant breast cancers and 43.8% benign breast lesions. MRI demonstrated a sensitivity of 0.91 (95% CI: 0.89-0.92) and a specificity of 0.84 (95% CI: 0.82-0.86) in differentiating between benign and malignant breast cancers. Mammography-based radiomic features predicted breast cancer subtype with a sensitivity of 0.79 (95% CI: 0.76-0.82) and a specificity of 0.81 (95% CI: 0.79-0.84). Ultrasound-based analysis yielded a sensitivity of 0.92 (95% CI: 0.90-0.94) and a specificity of 0.85 (95% CI: 0.83-0.88). Only one study reported the results of radiomic evaluation from CT, which had a sensitivity of 0.95 (95% CI: 0.88-0.99) and a specificity of 0.56 (95% CI: 0.45-0.67). Across different imaging modalities, radiomics exhibited robust diagnostic accuracy in differentiating benign and malignant breast lesions. The results underscore the potential of radiomic assessment as a minimally invasive alternative or adjunctive diagnostic tool for breast cancer. This is pioneering data that reports on a novel diagnostic approach that is understudied and underreported. However, due to study limitations, the complexity of this technology, and the need for future development, biopsy still remains the current gold standard method of determining breast cancer type.
Collapse
Affiliation(s)
- Ke En Oh
- Department of Surgery, University Hospital Galway, Galway, IRL
| | | | - Afiq Anwar
- Department of Surgery, University Hospital Galway, Galway, IRL
| |
Collapse
|
7
|
Qin Y, Tang C, Hu Q, Yi J, Yin T, Ai T. Assessment of Prognostic Factors and Molecular Subtypes of Breast Cancer With a Continuous-Time Random-Walk MR Diffusion Model: Using Whole Tumor Histogram Analysis. J Magn Reson Imaging 2023; 58:93-105. [PMID: 36251468 DOI: 10.1002/jmri.28474] [Citation(s) in RCA: 5] [Impact Index Per Article: 5.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/09/2022] [Revised: 09/28/2022] [Accepted: 09/29/2022] [Indexed: 11/07/2022] Open
Abstract
BACKGROUND The continuous-time random-walk (CTRW) diffusion model to evaluate breast cancer prognosis is rarely reported. PURPOSE To investigate the correlations between apparent diffusion coefficient (ADC) and CTRW-specific parameters with prognostic factors and molecular subtypes of breast cancer. STUDY TYPE Retrospective. POPULATION One hundred fifty-seven women (median age, 50 years; range, 26-81 years) with histopathology-confirmed breast cancer. FIELD STRENGTH/SEQUENCE Simultaneous multi-slice readout-segmented echo-planar imaging at 3.0T. ASSESSMENT The histogram metrics of ADC, anomalous diffusion coefficient (D), temporal diffusion heterogeneity (α), and spatial diffusion heterogeneity (β) were calculated for whole-tumor volume. Associations between histogram metrics and prognostic factors (estrogen receptor [ER], progesterone receptor [PR], human epidermal growth factor receptor 2 [HER2], and Ki-67 proliferation index), axillary lymph node metastasis (ALNM), and tumor grade were assessed. The performance of histogram metrics, both alone and in combination, for differentiating molecular subtypes (HER2-positive, Luminal or triple negative) was also assessed. STATISTICAL TESTS Comparisons were made using Mann-Whitney test between different prognostic factor statuses and molecular subtypes. Receiver operating characteristic curve analysis was used to assess the performance of mean and median histogram metrics in differentiating the molecular subtypes. A P value <0.05 was considered statistically significant. RESULTS The histogram metrics of ADC, D, and α differed significantly between ER-positive and ER-negative status, and between PR-positive and PR-negative status. The histogram metrics of ADC, D, α, and β were also significantly different between the HER2-positive and HER2-negative subgroups, and between ALNM-positive and ALNM-negative subgroups. The histogram metrics of α and β significantly differed between high and low Ki-67 proliferation subgroups, and between histological grade subgroups. The combination of αmean and βmean achieved the highest performance (AUC = 0.702) to discriminate the Luminal and HER2-positive subtypes. DATA CONCLUSION Whole-tumor histogram analysis of the CTRW model has potential to provide additional information on the prognosis and intrinsic subtyping classification of breast cancer. EVIDENCE LEVEL 4 TECHNICAL EFFICACY: Stage 2.
Collapse
Affiliation(s)
- Yanjin Qin
- Department of Radiology, Tongji Hospital, Tongji Medical College, Huazhong University of Science and Technology, Wuhan, China
| | - Caili Tang
- Department of Radiology, Tongji Hospital, Tongji Medical College, Huazhong University of Science and Technology, Wuhan, China
| | - Qilan Hu
- Department of Radiology, Tongji Hospital, Tongji Medical College, Huazhong University of Science and Technology, Wuhan, China
| | - Jingru Yi
- Department of Radiology, Tongji Hospital, Tongji Medical College, Huazhong University of Science and Technology, Wuhan, China
| | - Ting Yin
- MR Collaborations, Siemens Healthineers Ltd., Chengdu, China
| | - Tao Ai
- Department of Radiology, Tongji Hospital, Tongji Medical College, Huazhong University of Science and Technology, Wuhan, China
| |
Collapse
|
8
|
Mehta R, Bu Y, Zhong Z, Dan G, Zhong PS, Zhou C, Hu W, Zhou XJ, Xu M, Wang S, Karaman MM. Characterization of breast lesions using multi-parametric diffusion MRI and machine learning. Phys Med Biol 2023; 68:085006. [PMID: 36808921 DOI: 10.1088/1361-6560/acbde0] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/13/2022] [Accepted: 02/21/2023] [Indexed: 02/23/2023]
Abstract
Objective. To investigate quantitative imaging markers based on parameters from two diffusion-weighted imaging (DWI) models, continuous-time random-walk (CTRW) and intravoxel incoherent motion (IVIM) models, for characterizing malignant and benign breast lesions by using a machine learning algorithm.Approach. With IRB approval, 40 women with histologically confirmed breast lesions (16 benign, 24 malignant) underwent DWI with 11b-values (50 to 3000 s/mm2) at 3T. Three CTRW parameters,Dm,α, andβand three IVIM parametersDdiff,Dperf, andfwere estimated from the lesions. A histogram was generated and histogram features of skewness, variance, mean, median, interquartile range; and the value of the 10%, 25% and 75% quantiles were extracted for each parameter from the regions-of-interest. Iterative feature selection was performed using the Boruta algorithm that uses the Benjamin Hochberg False Discover Rate to first determine significant features and then to apply the Bonferroni correction to further control for false positives across multiple comparisons during the iterative procedure. Predictive performance of the significant features was evaluated using Support Vector Machine, Random Forest, Naïve Bayes, Gradient Boosted Classifier (GB), Decision Trees, AdaBoost and Gaussian Process machine learning classifiers.Main Results. The 75% quantile, and median ofDm; 75% quantile off;mean, median, and skewness ofβ;kurtosis ofDperf; and 75% quantile ofDdiffwere the most significant features. The GB differentiated malignant and benign lesions with an accuracy of 0.833, an area-under-the-curve of 0.942, and an F1 score of 0.87 providing the best statistical performance (p-value < 0.05) compared to the other classifiers.Significance. Our study has demonstrated that GB with a set of histogram features from the CTRW and IVIM model parameters can effectively differentiate malignant and benign breast lesions.
Collapse
Affiliation(s)
- Rahul Mehta
- Center for Magnetic Resonance Research, University of Illinois at Chicago, Chicago, IL, United States of America
- Department of Biomedical Engineering, University of Illinois at Chicago, Chicago, IL, United States of America
| | - Yangyang Bu
- The First School of Clinical Medicine of Zhejiang Chinese Medical University, Hangzhou, People's Republic of China
- Department of Radiology, The First Affiliated Hospital of Zhejiang Chinese Medical University, Hangzhou, People's Republic of China
| | - Zheng Zhong
- Center for Magnetic Resonance Research, University of Illinois at Chicago, Chicago, IL, United States of America
- Department of Biomedical Engineering, University of Illinois at Chicago, Chicago, IL, United States of America
| | - Guangyu Dan
- Center for Magnetic Resonance Research, University of Illinois at Chicago, Chicago, IL, United States of America
- Department of Biomedical Engineering, University of Illinois at Chicago, Chicago, IL, United States of America
| | - Ping-Shou Zhong
- Department of Mathematics, Statistics, and Computer Science, University of Illinois at Chicago, Chicago, IL, United States of America
| | - Changyu Zhou
- The First School of Clinical Medicine of Zhejiang Chinese Medical University, Hangzhou, People's Republic of China
- Department of Radiology, The First Affiliated Hospital of Zhejiang Chinese Medical University, Hangzhou, People's Republic of China
| | - Weihong Hu
- The First School of Clinical Medicine of Zhejiang Chinese Medical University, Hangzhou, People's Republic of China
- Department of Radiology, The First Affiliated Hospital of Zhejiang Chinese Medical University, Hangzhou, People's Republic of China
| | - Xiaohong Joe Zhou
- Departments of Radiology and Neurosurgery, University of Illinois at Chicago, Chicago, IL, United States of America
| | - Maosheng Xu
- The First School of Clinical Medicine of Zhejiang Chinese Medical University, Hangzhou, People's Republic of China
- Department of Radiology, The First Affiliated Hospital of Zhejiang Chinese Medical University, Hangzhou, People's Republic of China
| | - Shiwei Wang
- The First School of Clinical Medicine of Zhejiang Chinese Medical University, Hangzhou, People's Republic of China
- Department of Radiology, The First Affiliated Hospital of Zhejiang Chinese Medical University, Hangzhou, People's Republic of China
| | - M Muge Karaman
- Center for Magnetic Resonance Research, University of Illinois at Chicago, Chicago, IL, United States of America
- Department of Biomedical Engineering, University of Illinois at Chicago, Chicago, IL, United States of America
| |
Collapse
|
9
|
Wang C, Wang G, Zhang Y, Dai Y, Yang D, Wang C, Li J. Differentiation of benign and malignant breast lesions using diffusion-weighted imaging with a fractional-order calculus model. Eur J Radiol 2023; 159:110646. [PMID: 36577184 DOI: 10.1016/j.ejrad.2022.110646] [Citation(s) in RCA: 6] [Impact Index Per Article: 6.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/15/2022] [Revised: 11/25/2022] [Accepted: 12/07/2022] [Indexed: 12/23/2022]
Abstract
PURPOSE To assess the feasibility of using three diffusion parameters (D, β, and μ) derived from fractional-order calculus (FROC) diffusion model for improving the differentiation between benign and malignant breast lesions. METHOD In this prospective study, 103 patients with breast lesions were enrolled. All subjects underwent diffusion-weighted imaging (DWI) with 12b values. Inter-observer agreement with respect to quantification of parameters by two radiologists was assessed using intraclass coefficient. Conventional apparent diffusion coefficient (ADC) and three FROC model parameters D, β, and μ were compared between the benign lesion and malignant lesion groups using the Mann-Whitney U test. Then, a comprehensive prediction model was created by using binary logistic regression. Receiver operating characteristic (ROC) curve analysis was performed to evaluate the diagnostic performance of the parameters using histopathological diagnosis as the reference standard. RESULTS The FROC parameters and ADC all exhibited significant differences between benign lesions and malignant lesions (P<0.001). Among the individual parameters, the sensitivity of μ was higher than ADC (95.92% for μ vs 91.84% for ADC), and the specificity of β was higher than ADC (72.22% for β vs 70.37% for ADC). The combination of ADC and FROC parameters (D and β) generated the largest area under the ROC curve (0.841) when compared with individual parameters, indicating an improved performance for differentiating benign lesions from malignant lesions. CONCLUSIONS This study demonstrated the feasibility of using the FROC diffusion model to improve the accuracy of identifying malignant breast lesions.
Collapse
Affiliation(s)
- Chunhong Wang
- Department of Radiology, Xinyang Central Hospital, No. 01 Xinyang Siyi Road, Xinyang 464000, Henan, China
| | - Guanying Wang
- Department of Radiology, Xinyang Central Hospital, No. 01 Xinyang Siyi Road, Xinyang 464000, Henan, China
| | - Yunfei Zhang
- MR Collaboration, Central Research Institute, United Imaging Healthcare, Shanghai, China
| | - Yongming Dai
- MR Collaboration, Central Research Institute, United Imaging Healthcare, Shanghai, China
| | - Dan Yang
- Department of Radiology, Xinyang Central Hospital, No. 01 Xinyang Siyi Road, Xinyang 464000, Henan, China
| | - Changfu Wang
- Imaging department, Huaihe Hospital, Henan University, Kaifeng, 475000, Henan, China
| | - Jianhong Li
- Department of Radiology, Xinyang Central Hospital, No. 01 Xinyang Siyi Road, Xinyang 464000, Henan, China.
| |
Collapse
|
10
|
Preoperative assessment of microvascular invasion of hepatocellular carcinoma using non-Gaussian diffusion-weighted imaging with a fractional order calculus model: A pilot study. Magn Reson Imaging 2023; 95:110-117. [PMID: 34506910 DOI: 10.1016/j.mri.2021.09.003] [Citation(s) in RCA: 3] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/31/2021] [Revised: 09/05/2021] [Accepted: 09/05/2021] [Indexed: 12/15/2022]
Abstract
PURPOSE To assess the clinical potential of a set of new diffusion parameters (D, β, and μ) derived from fractional order calculus (FROC) diffusion model in predicting microvascular invasion (MVI) of hepatocellular carcinoma (HCC). MATERIALS AND METHODS Between January 2019 to November 2020, a total of 63 patients with HCC were enrolled in this study. Diffusion-weighted images were acquired by using ten b-values (0-2000 s/mm2). The FROC model parameters including diffusion coefficient (D), fractional order parameter (β), a microstructural quantity (μ) together with a conventional apparent diffusion coefficient (ADC) were calculated. Intraclass coefficients were calculated for assessing the agreement of parameters quantified by two radiologists. The differences of these values between the MVI-positive and MVI-negative HCC groups were compared by using independent sample t-test or the Mann-Whitney U test. Then the parameters showing significant differences between subgroups, including the β and D, were integrated to develop a comprehensive predictive model via binary logistic regression. The diagnostic performance was evaluated by receiver operating characteristic (ROC) analysis. RESULTS Among all the studied diffusion parameters, significant differences were found in D, β, and ADC between the MVI-positive and MVI-negative groups. MVI-positive HCCs showed significantly higher β values (0.65 ± 0.17 vs. 0.51 ± 0.13, P = 0.001), along with lower D values (0.84 ± 0.11 μm2/ms vs. 1.03 ± 0.13 μm2/ms, P < 0.001) and lower ADC values (1.38 ± 0.46 μm2/ms vs. 2.09 ± 0.70 μm2/ms, P < 0.001) than those of MVI-negative HCCs. According to the ROC analysis, the combination of D and β demonstrated the largest area under the ROC curve (0.920) compared with individual parameters (D: 0.912; β: 0.733; and ADC: 0.831) for differentiating MVI-positive from MVI-negative HCCs. CONCLUSIONS The FROC parameters can be used as noninvasive quantitative imaging markers for preoperatively predicting the MVI status of HCCs.
Collapse
|
11
|
Shao X, An L, Liu H, Feng H, Zheng L, Dai Y, Yu B, Zhang J. Cervical Carcinoma: Evaluation Using Diffusion MRI With a Fractional Order Calculus Model and its Correlation With Histopathologic Findings. Front Oncol 2022; 12:851677. [PMID: 35480091 PMCID: PMC9036957 DOI: 10.3389/fonc.2022.851677] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/10/2022] [Accepted: 03/03/2022] [Indexed: 11/13/2022] Open
Abstract
Objective The objective of the study is to investigate the feasibility of using the fractional order calculus (FROC) model to reflect tumor subtypes and histological grades of cervical carcinoma. Methods Sixty patients with untreated cervical carcinoma underwent multi-b-value diffusion-weighted imaging (DWI) at 3.0T magnetic resonance imaging (MRI). The mono-exponential and the FROC models were fitted. The differences in the histological subtypes and grades were evaluated by the Mann–Whitney U test. Receiver operating characteristic (ROC) analyses were performed to assess the diagnostic performance and to determine the best predictor for both univariate analysis and multivariate analysis. Differences between ROC curves were tested using the Hanley and McNeil test, while the sensitivity, specificity, and accuracy were compared using the McNemar test. P-value <0.05 was considered as significant difference. The Bonferroni corrections were applied to reduce problems associated with multiple comparisons. Results Only the parameter β, derived from the FROC model could differentiate cervical carcinoma subtypes (P = 0.03) and the squamous cell carcinoma (SCC) lesions exhibited significantly lower β than that in the adenocarcinoma (ACA) lesions. All the individual parameters, namely, ADC, β, D, and μ derived from the FROC model, could differentiate low-grade cervical carcinomas from high-grade ones (P = 0.022, 0.009, 0.004, and 0.015, respectively). The combination of all the FROC parameters showed the best overall performance, providing the highest sensitivity (81.2%) and AUC (0.829). Conclusion The parameters derived from the FROC model were able to differentiate the subtypes and grades of cervical carcinoma.
Collapse
Affiliation(s)
- Xian Shao
- Department of Anesthesiology, The Fourth Hospital of Shijiazhuang, Shijiazhuang, China
| | - Li An
- Department of Anesthesiology, The Fourth Hospital of Shijiazhuang, Shijiazhuang, China
| | - Hui Liu
- Department of Radiology, The Fourth Hospital of Hebei Medical University, Shijiazhuang, China
| | - Hui Feng
- Department of Radiology, The Fourth Hospital of Hebei Medical University, Shijiazhuang, China
| | - Liyun Zheng
- MR Collaboration, Central Research Institute, United Imaging Healthcare, Shanghai, China
| | - Yongming Dai
- MR Collaboration, Central Research Institute, United Imaging Healthcare, Shanghai, China
| | - Bin Yu
- Department of Emergency, The Fourth Hospital of Hebei Medical University, Shijiazhuang, China
| | - Jin Zhang
- Department of Anesthesiology, The Fourth Hospital of Shijiazhuang, Shijiazhuang, China
| |
Collapse
|
12
|
Shi B, Xue K, Yin Y, Xu Q, Shi B, Wu D, Ye J. Grading of clear cell renal cell carcinoma using diffusion MRI with a fractional order calculus model. Acta Radiol 2022; 64:421-430. [PMID: 35040361 DOI: 10.1177/02841851211072482] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/07/2023]
Abstract
BACKGROUND The fractional order calculus (FROC) model has been developed to describe restrained motion of water molecules as well as microstructural heterogeneity, providing a novel tool for non-invasive tumor grading. PURPOSE To evaluate the role of the FROC model in characterizing clear cell renal cell carcinoma (ccRCC) grades. MATERIAL AND METHODS A total of 59 patients diagnosed with ccRCC were included in this prospective study. The diffusion metrics derived from the mono-exponential model (apparent diffusion coefficient [ADC]), intra-voxel incoherent motion [IVIM] model [D, D*, f], and FROC model [Dfroc, β, μ]) were calculated and compared between low- and high-grade ccRCCs. Binary logistic regression analysis was performed to establish the diagnostic models. Receiver operating characteristic (ROC) analysis and DeLong test were performed to evaluate and compare the diagnostic performance of metrics in grading ccRCC. RESULTS All the metrics except D* and f exhibited statistical differences between low- and high-grade ccRCCs. ROC analysis showed individual FROC parameters, μ, Dfroc, and β, outperformed ADC and IVIM parameters in grading ccRCC. For single parameter, μ demonstrated the highest AUC value, sensitivity, and diagnostic accuracy in discriminating the two ccRCC groups while β exhibited the optimal specificity. Importantly, the combination of Dfroc, μ, and β could further improve the diagnostic performance. CONCLUSION The FROC parameters were superior to ADC and IVIM parameters in grading ccRCC, indicating the great potential of the FROC model in distinguishing low- and high-grade ccRCCs.
Collapse
Affiliation(s)
- Bowen Shi
- Department of Medical Imaging, Clinic Medical School, Yangzhou University, Northern Jiangsu Province Hospital, Yangzhou, PR China
| | - Ke Xue
- Central Research Institute, United Imaging Healthcare, Shanghai, PR China
| | - Yili Yin
- Department of Medical Imaging, Clinic Medical School, Yangzhou University, Northern Jiangsu Province Hospital, Yangzhou, PR China
| | - Qing Xu
- Department of Medical Imaging, Clinic Medical School, Yangzhou University, Northern Jiangsu Province Hospital, Yangzhou, PR China
| | - Binbin Shi
- Department of Medical Imaging, Clinic Medical School, Yangzhou University, Northern Jiangsu Province Hospital, Yangzhou, PR China
| | - Dongmei Wu
- Shanghai Key Laboratory of Magnetic Resonance, School of Physics and Electronics Science, East China Normal University, Shanghai, PR China
| | - Jing Ye
- Department of Medical Imaging, Clinic Medical School, Yangzhou University, Northern Jiangsu Province Hospital, Yangzhou, PR China
| |
Collapse
|
13
|
Mokry T, Pantke J, Mlynarska-Bujny A, Hasse FC, Kuder TA, Schlemmer HP, Kauczor HU, Rom J, Bickelhaupt S. Diffusivity mapping of the ovaries: Variability of apparent diffusion and kurtosis variables over the menstrual cycle and influence of oral contraceptives. Magn Reson Imaging 2021; 80:50-57. [PMID: 33905830 DOI: 10.1016/j.mri.2021.04.006] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/18/2020] [Revised: 04/14/2021] [Accepted: 04/21/2021] [Indexed: 11/26/2022]
Abstract
PURPOSE We aimed to investigate whether quantitative diffusivity variables of healthy ovaries vary during the menstrual cycle and to evaluate alterations in women using oral contraceptives (OC). METHODS This prospective study (S-339/2016) included 30 healthy female volunteers, with (n = 15) and without (n = 15) intake of OC between 07/2017 and 09/2019. Participants underwent 3T diffusion-weighted MRI (b-values 0-2000 s/mm2) three times during a menstrual cycle (T1 = day 1-5; T2 = day 7-12; T3 = day 19-24). Both ovaries were manually three-dimensionally segmented on b = 1500 s/mm2; apparent diffusion coefficient (ADC) calculation and kurtosis fitting (Dapp, Kapp) were performed. Differences in ADC, Dapp and Kapp between time points and groups were compared using repeated measures ANOVA and t-test after Shapiro-Wilk and Brown-Forsythe test for normality and equal variance. RESULTS In women with a natural menstrual cycle, ADC and kurtosis variables showed significant changes in ovaries with the dominant follicle between T1 vs T2 and T1 vs T3, whilst no differences were observed between T2 vs T3: ADC ± SD for T1 1.524 ± 0.160, T2 1.737 ± 0.160, and T3 1.747 ± 0.241 μm2/ms (p = 0.01 T2 vs T1; p = 1.0 T2 vs T3, p = 0.003 T3 vs T1); Dapp ± SD for T1 2.018 ± 0.140, T2 2.272 ± 0.189, and T3 2.230 ± 0.256 μm2/ms (p = 0.003 T2 vs T1, p = 1.0 T2 vs T3, p = 0.02 T3 vs T1); Kapp ± SD for T1 0.614 ± 0.0339, T2 0.546 ± 0.0637, and T3 0.529 ± 0.0567 (p < 0.001 T2 vs T1, p = 0.86 T2 vs T3, p < 0.001 T3 vs T1). No significant differences were found in the contralateral ovaries or in females taking OC. CONCLUSION Physiological cycle-dependent changes in quantitative diffusivity variables of ovaries should be considered especially when interpreting radiomics analyses in reproductive women.
Collapse
Affiliation(s)
- Theresa Mokry
- Department of Diagnostic and Interventional Radiology, Heidelberg University Hospital, Im Neuenheimer Feld 110, 69120 Heidelberg, Germany.
| | - Judith Pantke
- Department of Diagnostic and Interventional Radiology, Heidelberg University Hospital, Im Neuenheimer Feld 110, 69120 Heidelberg, Germany
| | - Anna Mlynarska-Bujny
- Department of Radiology, German Cancer Research Center, Heidelberg, Germany; Department of Medical Physics in Radiology, German Cancer Research Center, Heidelberg, Germany; Medical Faculty Heidelberg, Heidelberg University, Germany
| | - Felix Christian Hasse
- Department of Diagnostic and Interventional Radiology, Heidelberg University Hospital, Im Neuenheimer Feld 110, 69120 Heidelberg, Germany
| | - Tristan Anselm Kuder
- Department of Medical Physics in Radiology, German Cancer Research Center, Heidelberg, Germany
| | | | - Hans-Ulrich Kauczor
- Department of Diagnostic and Interventional Radiology, Heidelberg University Hospital, Im Neuenheimer Feld 110, 69120 Heidelberg, Germany
| | - Joachim Rom
- Hospital for General Obstetrics and Gynecology, Hospital Frankfurt Hoechst, Frankfurt, Germany
| | - Sebastian Bickelhaupt
- Department of Radiology, German Cancer Research Center, Heidelberg, Germany; Junior Group Medical Imaging and Radiology - Cancer Prevention, German Cancer Research Center, Heidelberg, Germany; Institute of Radiology, Erlangen University Hospital, Erlangen, Germany
| |
Collapse
|
14
|
Karaman MM, Tang L, Li Z, Sun Y, Li JZ, Zhou XJ. In vivo assessment of Lauren classification for gastric adenocarcinoma using diffusion MRI with a fractional order calculus model. Eur Radiol 2021; 31:5659-5668. [PMID: 33616764 DOI: 10.1007/s00330-021-07694-3] [Citation(s) in RCA: 8] [Impact Index Per Article: 2.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/25/2020] [Revised: 12/21/2020] [Accepted: 01/18/2021] [Indexed: 11/28/2022]
Abstract
OBJECTIVES To evaluate the performance of a fractional order calculus (FROC) diffusion model for imaging-based assessment of Lauren classification in gastric adenocarcinoma. METHODS In this study, 43 patients (15 females, 28 males) with gastric adenocarcinoma underwent MRI at 1.5 T. According to pathology-based Lauren classification, 10 patients had diffuse-type, 20 had intestinal-type, and 13 had mixed-type lesions. The diffuse and mixed types were combined as diffuse-and-mixed type to be differentiated from the intestinal type using diffusion MRI. Diffusion-weighted images were acquired by using eleven b-values (0-2000 s/mm2). Three FROC model parameters comprising diffusion coefficient D, intravoxel diffusion heterogeneity β, and a microstructural quantity μ, together with a conventional apparent diffusion coefficient (ADC), were estimated. The mean parameter values in the tumour were computed by using a percentile histogram analysis. Individual or linear combinations of the mean parameters in the tumour were used to differentiate the diffuse-and-mixed type from the intestinal type using descriptive statistics and receiver operating characteristic (ROC) analyses. RESULTS Significant differences were observed between diffuse-and-mixed-type and intestinal-type lesions in D (0.99 ± 0.20 μm2/ms vs. 1.11 ± 0.23 μm2/ms; p = 0.036), β (0.37 ± 0.08 vs. 0.43 ± 0.11; p = 0.043), μ (7.92 ± 2.79 μm vs. 9.87 ± 1.52 μm; p = 0.038), and ADC (0.81 ± 0.34 μm2/ms vs. 0.96 ± 0.19 μm2/ms; p = 0.033). Among the individual parameters, μ produced the largest area under the ROC curve (0.739). The combinations of (D, β, μ) and (β and μ) produced the best overall performance with a sensitivity of 0.739, specificity of 0.750, accuracy of 0.744, and area under the curve of 0.793 (95% confidence interval: 0.657-0.929). CONCLUSION Diffusion MRI with the FROC model holds promise for non-invasive assessment of Lauren classification for gastric adenocarcinoma. KEY POINTS • High b-value diffusion MRI with a FROC model that is sensitive to tissue microstructures can differentiate the diffuse-and-mixed type from intestinal type of gastric adenocarcinoma. • The combination of FROC parameters produced the best result for distinguishing the diffuse-and-mixed type from the intestinal type with an area under the receiver operating characteristic curve of 0.793. • The FROC model parameters, individually or conjointly, hold promise for repeated, non-invasive evaluations of gastric adenocarcinoma at various time points throughout disease progression or regression to complement conventional Lauren classification.
Collapse
Affiliation(s)
- M Muge Karaman
- Center for MR Research, University of Illinois at Chicago, Chicago, IL, USA.,Department of Bioengineering, University of Illinois at Chicago, Chicago, IL, USA
| | - Lei Tang
- Department of Radiology, Peking University Cancer Hospital and Institute, Beijing, China
| | - Ziyu Li
- Department of Gastrointestinal Surgery, Peking University Cancer Hospital and Institute, Beijing, China
| | - Yu Sun
- Department of Pathology, Peking University Cancer Hospital and Institute, Beijing, China
| | - Jia-Zheng Li
- Department of Radiology, Peking University Cancer Hospital and Institute, Beijing, China
| | - Xiaohong Joe Zhou
- Center for MR Research, University of Illinois at Chicago, Chicago, IL, USA. .,Department of Bioengineering, University of Illinois at Chicago, Chicago, IL, USA. .,Departments of Radiology and Neurosurgery, University of Illinois at Chicago, Chicago, IL, USA. .,Center for Magnetic Resonance Research, University of Illinois at Chicago, 2242 West Harrison Street, Suite 103, M/C 831, Chicago, IL, 60612, USA.
| |
Collapse
|
15
|
Tuza FADA, de Sá PM, Castro HA, Lopes AJ, de Melo PL. Combined forced oscillation and fractional-order modeling in patients with work-related asthma: a case-control study analyzing respiratory biomechanics and diagnostic accuracy. Biomed Eng Online 2020; 19:93. [PMID: 33298072 PMCID: PMC7724713 DOI: 10.1186/s12938-020-00836-6] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/25/2020] [Accepted: 11/23/2020] [Indexed: 12/03/2022] Open
Abstract
BACKGROUND Fractional-order (FrOr) models have a high potential to improve pulmonary science. These models could be useful for biomechanical studies and diagnostic purposes, offering accurate models with an improved ability to describe nature. This paper evaluates the performance of the Forced Oscillation (FO) associated with integer (InOr) and FrOr models in the analysis of respiratory alterations in work-related asthma (WRA). METHODS Sixty-two individuals were evaluated: 31 healthy and 31 with WRA with mild obstruction. Patients were analyzed pre- and post-bronchodilation. The diagnostic accuracy was evaluated using the area under the receiver operating characteristic curve (AUC). To evaluate how well do the studied models correspond to observed data, we analyzed the mean square root of the sum (MSEt) and the relative distance (Rd) of the estimated model values to the measured resistance and reactance measured values. RESULTS AND DISCUSSION Initially, the use of InOr and FrOr models increased our understanding of the WRA physiopathology, showing increased peripheral resistance, damping, and hysteresivity. The FrOr model (AUC = 0.970) outperformed standard FO (AUC = 0.929), as well as InOr modeling (AUC = 0.838) in the diagnosis of respiratory changes, achieving high accuracy. FrOr improved the curve fitting (MSEt = 0.156 ± 0.340; Rd = 3.026 ± 1.072) in comparison with the InOr model (MSEt = 0.367 ± 0.991; Rd = 3.363 ± 1.098). Finally, we demonstrated that bronchodilator use increased dynamic compliance, as well as reduced damping and peripheral resistance. CONCLUSIONS Taken together, these results show clear evidence of the utility of FO associated with fractional-order modeling in patients with WRA, improving our knowledge of the biomechanical abnormalities and the diagnostic accuracy in this disease.
Collapse
Affiliation(s)
- Fábio Augusto D Alegria Tuza
- Biomedical Instrumentation Laboratory, Institute of Biology and Faculty of Engineering, State University of Rio de Janeiro, Haroldo Lisboa da Cunha Pavilion Number 104 and 105, São Francisco Xavier Street 524 Maracanã, Rio de Janeiro, RJ, 20550-013, Brazil
- BioVasc Research Laboratory, Institute of Biology, State University of Rio de Janeiro, Rio de Janeiro, Brazil
| | - Paula Morisco de Sá
- Biomedical Instrumentation Laboratory, Institute of Biology and Faculty of Engineering, State University of Rio de Janeiro, Haroldo Lisboa da Cunha Pavilion Number 104 and 105, São Francisco Xavier Street 524 Maracanã, Rio de Janeiro, RJ, 20550-013, Brazil
- BioVasc Research Laboratory, Institute of Biology, State University of Rio de Janeiro, Rio de Janeiro, Brazil
| | - Hermano A Castro
- National School of Public Health, Oswaldo Cruz Foundation, Rio de Janeiro, Brazil
| | - Agnaldo José Lopes
- School of Medical Sciences, Pulmonary Function Testing Laboratory, State University of Rio de Janeiro, Rio de Janeiro, RJ, Brazil
- Rehabilitation Sciences Post-Graduation Program, Augusto Motta University Centre, Rio de Janeiro, Brazil
| | - Pedro Lopes de Melo
- Biomedical Instrumentation Laboratory, Institute of Biology and Faculty of Engineering, State University of Rio de Janeiro, Haroldo Lisboa da Cunha Pavilion Number 104 and 105, São Francisco Xavier Street 524 Maracanã, Rio de Janeiro, RJ, 20550-013, Brazil.
- BioVasc Research Laboratory, Institute of Biology, State University of Rio de Janeiro, Rio de Janeiro, Brazil.
| |
Collapse
|
16
|
Ribeiro CO, Lopes AJ, de Melo PL. Oscillation Mechanics, Integer and Fractional Respiratory Modeling in COPD: Effect of Obstruction Severity. Int J Chron Obstruct Pulmon Dis 2020; 15:3273-3289. [PMID: 33324050 PMCID: PMC7733470 DOI: 10.2147/copd.s276690] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/12/2020] [Accepted: 11/09/2020] [Indexed: 12/28/2022] Open
Abstract
Purpose This research examines the emerging role of respiratory oscillometry associated with integer (InOr) and fractional order (FrOr) respiratory models in the context of groups of patients with increasing severity. The contributions to our understanding of the respiratory abnormalities along the course of increasing COPD severity and the diagnostic use of this method were also evaluated. Patients and Methods Forty-five individuals with no history of smoking or pulmonary diseases (control group) and 141 individuals with diagnoses of COPD were studied, being classified into 45 mild, 42 moderate, 36 severe and 18 very severe cases. Results This study has shown initially that the course of increasing COPD severity was adequately described by the model parameters. This resulted in significant and consistent correlations among these parameters and spirometric indexes. Additionally, this evaluation enhanced our understanding of the respiratory abnormalities in different COPD stages. The diagnostic accuracy analyses provided evidence that hysteresivity, obtained from FrOr modeling, allowed a highly accurate identification in patients with mild changes [area under the receiver operator characteristic curve (AUC)= 0.902]. Similar analyses in groups of moderate and severe patients showed that peripheral resistance, derived from InOr modeling, provided the most accurate parameter (AUC=0.898 and 0.998, respectively), while in very severe patients, traditional, InOr and FrOr parameters were able to reach high diagnostic accuracy (AUC>0.9). Conclusion InOr and FrOr modeling improved our knowledge of the respiratory abnormalities along the course of increasing COPD severity. In addition, the present study provides evidence that these models may contribute in the diagnosis of COPD. Respiratory oscillometry exams require only tidal breathing and are easy to perform. Taken together, these practical considerations and the results of the present study suggest that respiratory oscillometry associated with InOr and FrOr models may help to improve lung function tests in COPD.
Collapse
Affiliation(s)
- Caroline Oliveira Ribeiro
- Biomedical Instrumentation Laboratory, Institute of Biology and Faculty of Engineering, State University of Rio de Janeiro, Rio de Janeiro, Brazil
| | - Agnaldo José Lopes
- Pulmonary Function Laboratory, State University of Rio de Janeiro, Rio de Janeiro, Brazil.,Pulmonary Rehabilitation Laboratory, Augusto Motta University Center, Rio de Janeiro, Brazil
| | - Pedro Lopes de Melo
- Biomedical Instrumentation Laboratory, Institute of Biology and Faculty of Engineering, State University of Rio de Janeiro, Rio de Janeiro, Brazil
| |
Collapse
|
17
|
Mlynarska-Bujny A, Bickelhaupt S, Laun FB, König F, Lederer W, Daniel H, Ladd ME, Schlemmer HP, Delorme S, Kuder TA. Influence of residual fat signal on diffusion kurtosis MRI of suspicious mammography findings. Sci Rep 2020; 10:13286. [PMID: 32764721 PMCID: PMC7413543 DOI: 10.1038/s41598-020-70154-3] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/17/2019] [Accepted: 07/17/2020] [Indexed: 01/10/2023] Open
Abstract
Recent studies showed the potential of diffusion kurtosis imaging (DKI) as a tool for improved classification of suspicious breast lesions. However, in diffusion-weighted imaging of the female breast, sufficient fat suppression is one of the main factors determining the success. In this study, the data of 198 patients examined in two study centres was analysed using standard diffusion and kurtosis evaluation methods and three DKI fitting approaches accounting phenomenologically for fat-related signal contamination of the lesions. Receiver operating characteristic curve analysis showed the highest area under the curve (AUC) for the method including fat correction terms (AUC = 0.85, p < 0.015) in comparison to the values obtained with the standard diffusion (AUC = 0.77) and kurtosis approach (AUC = 0.79). Comparing the two study centres, the AUC value improved from 0.77 to 0.86 (p = 0.036) using a fat correction term for the first centre, while no significant difference with no adverse effects was observed for the second centre (AUC 0.89 vs. 0.90, p = 0.95). Contamination of the signal in breast lesions with unsuppressed fat causing a reduction of diagnostic performance of diffusion kurtosis imaging may potentially be counteracted by proposed adapted evaluation methods.
Collapse
Affiliation(s)
- Anna Mlynarska-Bujny
- Department of Radiology, German Cancer Research Center (DKFZ), Heidelberg, Germany.,Department of Medical Physics in Radiology, German Cancer Research Center (DKFZ), Im Neuenheimer Feld 280, 69120, Heidelberg, Germany.,Faculty of Medicine, University of Heidelberg, Heidelberg, Germany
| | - Sebastian Bickelhaupt
- Junior Group Medical Imaging and Radiology - Cancer Prevention, German Cancer Research Center (DKFZ), Heidelberg, Germany.,Institute of Radiology, University Hospital Erlangen, Friedrich-Alexander-Universität Erlangen-Nürnberg (FAU), Erlangen, Germany
| | - Frederik Bernd Laun
- Institute of Radiology, University Hospital Erlangen, Friedrich-Alexander-Universität Erlangen-Nürnberg (FAU), Erlangen, Germany
| | - Franziska König
- Department of Radiology, German Cancer Research Center (DKFZ), Heidelberg, Germany
| | - Wolfgang Lederer
- Radiological Clinic at the ATOS Clinic Heidelberg, Heidelberg, Germany
| | - Heidi Daniel
- Radiology Center Mannheim (RZM), Mannheim, Germany
| | - Mark Edward Ladd
- Department of Medical Physics in Radiology, German Cancer Research Center (DKFZ), Im Neuenheimer Feld 280, 69120, Heidelberg, Germany.,Faculty of Medicine, University of Heidelberg, Heidelberg, Germany.,Faculty of Physics and Astronomy, University of Heidelberg, Heidelberg, Germany
| | - Heinz-Peter Schlemmer
- Department of Radiology, German Cancer Research Center (DKFZ), Heidelberg, Germany.,Faculty of Medicine, University of Heidelberg, Heidelberg, Germany
| | - Stefan Delorme
- Department of Radiology, German Cancer Research Center (DKFZ), Heidelberg, Germany
| | - Tristan Anselm Kuder
- Department of Medical Physics in Radiology, German Cancer Research Center (DKFZ), Im Neuenheimer Feld 280, 69120, Heidelberg, Germany.
| |
Collapse
|
18
|
Chen W, Zhu LN, Dai YM, Jiang JS, Bu SS, Xu XQ, Wu FY. Differentiation of salivary gland tumor using diffusion-weighted imaging with a fractional order calculus model. Br J Radiol 2020; 93:20200052. [PMID: 32649236 DOI: 10.1259/bjr.20200052] [Citation(s) in RCA: 8] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/29/2022] Open
Abstract
OBJECTIVE To evaluate the feasibility of using imaging parameters (D, β and μ) obtained from fractional order calculus (FROC) diffusion model to differentiate salivary gland tumors. METHODS 15 b-value (0-2000 s/mm2) diffusion-weighted imaging (DWI) was scanned in 62 patients with salivary gland tumors (47 benign and 15 malignant). Diffusion coefficient D, fractional order parameter β (which correlates with tissue heterogeneity) and a microstructural quantity μ of the solid portion within the tumor were calculated, and compared between benign and malignant groups, or among pleomorphic adenoma (PA), Warthin's tumor (WT), and malignant tumor (MT) groups. Performance of FROC parameters for differentiation was assessed using receiver operating characteristic analysis. RESULTS None of the FROC parameters exhibited significant differences between benign and malignant group (D, p = 0.150; β, p = 0.967; μ, p = 0.693). WT showed significantly lower D (p < 0.001) and β (p < 0.001), while higher μ (p = 0.001) than PA. Combination of D, β and μ showed optimal diagnostic performance (area under the curve, AUC, 0.998). MT showed significantly lower D (p = 0.001) and β (p = 0.025) than PA, while no significant difference was found on μ (p = 0.064). Combination of D and β showed optimal diagnostic performance (AUC, 0.933). Significant difference was found on β (p = 0.027) between MT and WT, while not on D (p = 0.806) and μ (p = 0.789). Setting a βof 0.615 as the cut-off value, optimal diagnostic performance could be obtained (AUC = 0.806). CONCLUSION A non-Gaussian FROC diffusion model can serve as a noninvasive and quantitative imaging technique for differentiating salivary gland tumors. ADVANCES IN KNOWLEDGE (1) PA showed higher D and β and lower μ than WT. (2) PA had higher D and β than MT. (3) WT demonstrated lower β than MT. (4) β, as a new FROC parameter, could offer an added value to the differentiation.
Collapse
Affiliation(s)
- Wei Chen
- Department of Radiology, The First Affiliated Hospital of Nanjing Medical University, Nanjing, China
| | - Liu-Ning Zhu
- Department of Stomatology, The First Affiliated Hospital of Nanjing Medical University, Nanjing, China
| | - Yong-Ming Dai
- United Imaging Healthcare, Central Research Institute, Shanghai, China
| | - Jia-Suo Jiang
- Department of Radiology, The First Affiliated Hospital of Nanjing Medical University, Nanjing, China
| | - Shou-Shan Bu
- Department of Stomatology, The First Affiliated Hospital of Nanjing Medical University, Nanjing, China
| | - Xiao-Quan Xu
- Department of Radiology, The First Affiliated Hospital of Nanjing Medical University, Nanjing, China
| | - Fei-Yun Wu
- Department of Radiology, The First Affiliated Hospital of Nanjing Medical University, Nanjing, China
| |
Collapse
|
19
|
Chhetri A, Li X, Rispoli JV. Current and Emerging Magnetic Resonance-Based Techniques for Breast Cancer. Front Med (Lausanne) 2020; 7:175. [PMID: 32478083 PMCID: PMC7235971 DOI: 10.3389/fmed.2020.00175] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/15/2019] [Accepted: 04/15/2020] [Indexed: 01/10/2023] Open
Abstract
Breast cancer is the most commonly diagnosed cancer among women worldwide, and early detection remains a principal factor for improved patient outcomes and reduced mortality. Clinically, magnetic resonance imaging (MRI) techniques are routinely used in determining benign and malignant tumor phenotypes and for monitoring treatment outcomes. Static MRI techniques enable superior structural contrast between adipose and fibroglandular tissues, while dynamic MRI techniques can elucidate functional characteristics of malignant tumors. The preferred clinical procedure-dynamic contrast-enhanced MRI-illuminates the hypervascularity of breast tumors through a gadolinium-based contrast agent; however, accumulation of the potentially toxic contrast agent remains a major limitation of the technique, propelling MRI research toward finding an alternative, noninvasive method. Three such techniques are magnetic resonance spectroscopy, chemical exchange saturation transfer, and non-contrast diffusion weighted imaging. These methods shed light on underlying chemical composition, provide snapshots of tissue metabolism, and more pronouncedly characterize microstructural heterogeneity. This review article outlines the present state of clinical MRI for breast cancer and examines several research techniques that demonstrate capacity for clinical translation. Ultimately, multi-parametric MRI-incorporating one or more of these emerging methods-presently holds the best potential to afford improved specificity and deliver excellent accuracy to clinics for the prediction, detection, and monitoring of breast cancer.
Collapse
Affiliation(s)
- Apekshya Chhetri
- Magnetic Resonance Biomedical Engineering Laboratory, Weldon School of Biomedical Engineering, Purdue University, West Lafayette, IN, United States
- Basic Medical Sciences, College of Veterinary Medicine, Purdue University, West Lafayette, IN, United States
| | - Xin Li
- Magnetic Resonance Biomedical Engineering Laboratory, Weldon School of Biomedical Engineering, Purdue University, West Lafayette, IN, United States
| | - Joseph V. Rispoli
- Magnetic Resonance Biomedical Engineering Laboratory, Weldon School of Biomedical Engineering, Purdue University, West Lafayette, IN, United States
- Center for Cancer Research, Purdue University, West Lafayette, IN, United States
- School of Electrical & Computer Engineering, Purdue University, West Lafayette, IN, United States
| |
Collapse
|
20
|
Abstract
Non-invasive magnetic resonance imaging (MRI) techniques are increasingly applied in the clinic with a fast growing body of evidence regarding its value for clinical decision making. In contrast to biochemical or histological markers, the key advantages of imaging biomarkers are the non-invasive nature and the spatial and temporal resolution of these approaches. The following chapter focuses on clinical applications of novel MR biomarkers in humans with a strong focus on oncologic diseases. These include both clinically established biomarkers (part 1-4) and novel MRI techniques that recently demonstrated high potential for clinical utility (part 5-7).
Collapse
Affiliation(s)
- Daniel Paech
- Division of Radiology, German Cancer Research Center (DKFZ), Im Neuenheimer Feld 280, 69120, Heidelberg, Germany
| | - Heinz-Peter Schlemmer
- Division of Radiology, German Cancer Research Center (DKFZ), Im Neuenheimer Feld 280, 69120, Heidelberg, Germany.
| |
Collapse
|
21
|
Chen S, Guan X, Shu Z, Li Y, Cao W, Dong F, Zhang M, Shao G, Shao F. A New Application of Multimodality Radiomics Improves Diagnostic Accuracy of Nonpalpable Breast Lesions in Patients with Microcalcifications-Only in Mammography. Med Sci Monit 2019; 25:9786-9793. [PMID: 31860635 PMCID: PMC6936317 DOI: 10.12659/msm.918721] [Citation(s) in RCA: 9] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/24/2022] Open
Abstract
Background The aim of this study was to assess a radiomic scheme that combines image features from digital mammography and dynamic contrast-enhanced MRI to improve classification accuracy of nonpalpable breast lesion (NBL) with Breast Imaging-Reporting and Data System (BI-RADS) 3–5 microcalcifications-only in mammography. Material/Methods This retrospective study was approved by the Internal Research Review and Ethical Committee of our hospital. We included 81 patients who underwent a three-dimensional digital breast X-ray wire positioning for local resection between October 2012 and November 2016. All patients underwent breast MRI and mammography before the treatment, and all obtained pathological confirmation. According to the pathological results, 41 patients with benign lesions were assigned to the benign group and 40 patients with malignant lesions were assigned to the malignant group. We used the random forest algorithm to select significant features and to test the single and multimodal classifiers using the Leave-One-Out-Cross-Validation method. An area under the receiver operating characteristic curve was also used to evaluate its discriminating performance. Results The multimodal classifier achieved AUC of 0.903, with a sensitivity of 82.5% and a specificity of 80.48%, which was better than any single modality. Conclusions Multimodal radiomics classification shows promising power in discriminating malignant lesions from benign lesions in NBL patients with BI-RADS 3–5 microcalcifications-only in mammography.
Collapse
Affiliation(s)
- Shujun Chen
- Institute of Cancer and Basic Medicine (ICBM), Chinese Academy of Sciences, Hangzhou, Zhejiang, China (mainland).,Department of Radiology, Cancer Hospital of The University of Chinese Academy of Sciences, Hangzhou, Zhejiang, China (mainland).,Department of Radiology, Zhejiang Cancer Hospital, Hangzhou, Zhejiang, China (mainland)
| | - Xiaojun Guan
- Department of Radiology, 2nd Affiliated Hospital, Zhejiang University School of Medicine, Hangzhou, Zhejiang, China (mainland)
| | - Zhenyu Shu
- Department of Radiology, Zhejiang Provincial People's Hospital, Affiliated People's Hospital of Hangzhou Medical College, Hangzhou, Zhejiang, China (mainland)
| | - Yongfeng Li
- Institute of Cancer and Basic Medicine (ICBM), Chinese Academy of Sciences, Hangzhou, Zhejiang, China (mainland).,Department of Breast Surgery, Cancer Hospital of The University of Chinese Academy of Sciences, Hangzhou, Zhejiang, China (mainland).,Department of Breast Surgery, Zhejiang Cancer Hospital, Hangzhou, Zhejiang, China (mainland)
| | - Wenming Cao
- Institute of Cancer and Basic Medicine (ICBM), Chinese Academy of Sciences, Hangzhou, Zhejiang, China (mainland).,Department of Breast Oncology, Zhejiang Cancer Hospital, Hangzhou, Zhejiang, China (mainland).,Department of Breast Oncology, Cancer Hospital of The University of Chinese Academy of Sciences, Hangzhou, Zhejiang, China (mainland)
| | - Fei Dong
- Department of Radiology, 2nd Affiliated Hospital, Zhejiang University School of Medicine, Hangzhou, Zhejiang, China (mainland)
| | - Minming Zhang
- Department of Radiology, 2nd Affiliated Hospital, Zhejiang University School of Medicine, Hangzhou, Zhejiang, China (mainland)
| | - Guoliang Shao
- Institute of Cancer and Basic Medicine (ICBM), Chinese Academy of Sciences, Hangzhou, Zhejiang, China (mainland).,Department of Radiology, Cancer Hospital of the University of Chinese Academy of Sciences, Hangzhou, Zhejiang, China (mainland).,Department of Radiology, Zhejiang Cancer Hospital, Hangzhou, Zhejiang, China (mainland)
| | - Feng Shao
- Institute of Cancer and Basic Medicine (ICBM), Chinese Academy of Sciences, Hangzhou, Zhejiang, China (mainland).,Department of Gynecological Oncology, Cancer Hospital of The University of Chinese Academy of Sciences, Hangzhou, Zhejiang, China (mainland).,Department of Gynecological Oncology, Zhejiang Cancer Hospital, Hangzhou, Zhejiang, China (mainland)
| |
Collapse
|
22
|
Simultaneous Multislice Echo Planar Imaging for Accelerated Diffusion-Weighted Imaging of Malignant and Benign Breast Lesions. Invest Radiol 2019; 54:524-530. [DOI: 10.1097/rli.0000000000000560] [Citation(s) in RCA: 30] [Impact Index Per Article: 6.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/21/2022]
|
23
|
Negrão de Figueiredo G, Ingrisch M, Fallenberg EM. Digital Analysis in Breast Imaging. Breast Care (Basel) 2019; 14:142-150. [PMID: 31316312 DOI: 10.1159/000501099] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/25/2019] [Accepted: 05/21/2019] [Indexed: 01/02/2023] Open
Abstract
Breast imaging is a multimodal approach that plays an essential role in the diagnosis of breast cancer. Mammography, sonography, magnetic resonance, and image-guided biopsy are imaging techniques used to search for malignant changes in the breast or precursors of malignant changes in, e.g., screening programs or follow-ups after breast cancer treatment. However, these methods still have some disadvantages such as interobserver variability and the mammography sensitivity in women with radiologically dense breasts. In order to overcome these difficulties and decrease the number of false positive findings, improvements in imaging analysis with the help of artificial intelligence are constantly being developed and tested. In addition, the extraction and correlation of imaging features with special tumor characteristics and genetics of the patients in order to get more information about treatment response, prognosis, and also cancer risk are coming more and more in focus. The aim of this review is to address recent developments in digital analysis of images and demonstrate their potential value in multimodal breast imaging.
Collapse
Affiliation(s)
| | - Michael Ingrisch
- Department of Radiology, Ludwig Maximilian University of Munich - Grosshadern Campus, Munich, Germany
| | - Eva Maria Fallenberg
- Department of Radiology, Ludwig Maximilian University of Munich - Grosshadern Campus, Munich, Germany
| |
Collapse
|
24
|
Threshold Isocontouring on High b-Value Diffusion-Weighted Images in Magnetic Resonance Mammography. J Comput Assist Tomogr 2019; 43:434-442. [PMID: 31082949 DOI: 10.1097/rct.0000000000000868] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/25/2022]
Abstract
OBJECTIVES Motivated by the similar appearance of malignant breast lesions in high b-value diffusion-weighted imaging (DWI) and positron emission tomography, the purpose of this work was to evaluate the applicability of a threshold isocontouring approach commonly used in positron emission tomography to analyze DWI data acquired from female human breasts with minimal interobserver variability. METHODS Twenty-three female participants (59.4 ± 10.0 years) with 23 lesions initially classified as suggestive of cancers in x-ray mammography screening were subsequently imaged on a 1.5-T magnetic resonance imaging scanner. Diffusion-weighted imaging was performed prior to biopsy with b values of 0, 100, 750, and 1500 s/mm. Isocontouring with different threshold levels was performed on the highest b-value image to determine the voxels used for subsequent evaluation of diffusion metrics. The coefficient of variation was computed by specifying 4 different regions of interest drawn around the lesion. Additionally, a receiver operating statistical analysis was performed. RESULTS Using a relative threshold level greater than or equal to 0.85 almost completely suppresses the intra-individual and inter-individual variability. Among 4 studied diffusion metrics, the diffusion coefficients from the intravoxel incoherent motion model returned the highest area under curve value of 0.9. The optimal cut-off diffusivity was found to be 0.85 μm/ms with a sensitivity of 87.5% and specificity of 90.9%. CONCLUSION Threshold isocontouring on high b-value maps is a viable approach to reliably evaluate DWI data of suspicious focal lesions in magnetic resonance mammography.
Collapse
|
25
|
Marinho CDL, Maioli MCP, do Amaral JLM, Lopes AJ, de Melo PL. Respiratory resistance and reactance in adults with sickle cell anemia: Part 2-Fractional-order modeling and a clinical decision support system for the diagnosis of respiratory disorders. PLoS One 2019; 14:e0213257. [PMID: 30845242 PMCID: PMC6405112 DOI: 10.1371/journal.pone.0213257] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/07/2018] [Accepted: 02/19/2019] [Indexed: 11/20/2022] Open
Abstract
BACKGROUND A better understanding of sickle cell anemia (SCA) and improvements in drug therapy and health policy have contributed to the emergence of a large population of adults living with this disease. The mechanisms by which SCA produces adverse effects on the respiratory system of these patients are largely unknown. Fractional-order (FrOr) models have a high potential to improve pulmonary clinical science and could be useful for diagnostic purposes, offering accurate models with an improved ability to mimic nature. Part 2 of this two-part study examines the changes in respiratory mechanics in patients with SCA using the new perspective of the FrOr models. These results are compared with those obtained in traditional forced oscillation (FOT) parameters, investigated in Part 1 of the present study, complementing this first analysis. METHODOLOGY/PRINCIPAL FINDINGS The data consisted of three categories of subjects: controls (n = 23), patients with a normal spirometric exam (n = 21) and those presenting restriction (n = 24). The diagnostic accuracy was evaluated by investigating the area under the receiver operating characteristic curve (AUC). Initially, it was observed that biomechanical changes in SCA included increased values of fractional inertance, as well as damping and hysteresivity (p<0.001). The correlation analysis showed that FrOr parameters are associated with functional exercise capacity (R = -0.57), pulmonary diffusion (R = -0.71), respiratory muscle performance (R = 0.50), pulmonary flows (R = -0.62) and airway obstruction (R = 0.60). Fractional-order modeling showed high diagnostic accuracy in the detection of early respiratory abnormalities (AUC = 0.93), outperforming spirometry (p<0.03) and standard FOT analysis (p<0.01) used in Part 1 of this study. A combination of machine learning methods with fractional-order modeling further improved diagnostic accuracy (AUC = 0.97). CONCLUSIONS FrOr modeling improved our knowledge about the biomechanical abnormalities in adults with SCA. Changes in FrOr parameters are associated with functional exercise capacity decline, abnormal pulmonary mechanics and diffusion. FrOr modeling outperformed spirometric and traditional forced oscillation analyses, showing a high diagnostic accuracy in the diagnosis of early respiratory abnormalities that was further improved by an automatic clinical decision support system. This finding suggested the potential utility of this combination to help identify early respiratory changes in patients with SCA.
Collapse
Affiliation(s)
- Cirlene de Lima Marinho
- Biomedical Instrumentation Laboratory—Institute of Biology and Faculty of Engineering, and BioVasc Research Laboratory—Institute of Biology, State University of Rio de Janeiro, Rio de Janeiro, Brazil
| | | | - Jorge Luis Machado do Amaral
- Department of Electronics and Telecommunications Engineering, State University of Rio de Janeiro, Rio de Janeiro, Brazil
| | - Agnaldo José Lopes
- School of Medical Sciences, Pulmonary Function Testing Laboratory, Rio de Janeiro/RJ, State University of Rio de Janeiro, Rio de Janeiro, Brazil
- Rehabilitation Sciences Post-Graduation Program, Augusto Motta University Centre, Rio de Janeiro, Brazil
| | - Pedro Lopes de Melo
- Biomedical Instrumentation Laboratory—Institute of Biology and Faculty of Engineering, and BioVasc Research Laboratory—Institute of Biology, State University of Rio de Janeiro, Rio de Janeiro, Brazil
| |
Collapse
|
26
|
Tan H, Chen J, Zhao YL, Liu JH, Zhang L, Liu CS, Huang D. Feasibility of Intravoxel Incoherent Motion for Differentiating Benign and Malignant Thyroid Nodules. Acad Radiol 2019; 26:147-153. [PMID: 29908978 DOI: 10.1016/j.acra.2018.05.011] [Citation(s) in RCA: 8] [Impact Index Per Article: 1.6] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/15/2017] [Revised: 04/29/2018] [Accepted: 05/02/2018] [Indexed: 12/29/2022]
Abstract
RATIONALE AND OBJECTIVES This study aimed to preliminarily investigate the feasibility of intravoxel incoherent motion (IVIM) theory in the differential diagnosis of benign and malignant thyroid nodules. MATERIALS AND METHODS Forty-five patients with 56 confirmed thyroid nodules underwent preoperative routine magnetic resonance imaging and IVIM diffusion-weighted imaging. The histopathologic diagnosis was confirmed by surgery. Apparent diffusion coefficient (ADC), perfusion fraction f, diffusivity D, and pseudo-diffusivity D* were quantified. Independent samples t test of IVIM-derived metrics were conducted between benign and malignant nodules. Receiver-operating characteristic analyses were performed to determine the optimal thresholds as well as the sensitivity and specificity for differentiating. RESULTS Significant intergroup difference was observed in ADC, D, D*, and f (p < 0.001). Malignant tumors featured significantly lower ADC, D and D* values and a higher f value than that of benign nodules. The ADC, D, and D* could distinguish the benign from malignant thyroid nodules, and parameter f differentiate the malignant tumors from benign nodules. The values of the area under the curve for parameter ADC, D, and D* were 0.784 (p = 0.001), 0.795 (p = 0.001), and 0.850 (p < 0.001), separately, of which the area under the curve of f value was the maximum for identifying the malignant from benign nodules, which was 0.841 (p < 0.001). CONCLUSION This study suggested that ADC and IVIM-derived metrics, including D, D*, and f, could potentially serve as noninvasive predictors for the preoperative differentiating of thyroid nodules, and f value performed best in identifying the malignant from benign nodules among these parameters.
Collapse
Affiliation(s)
- Hui Tan
- Department of Radiology, Renmin Hospital of Wuhan University, No. 99, Zhang Zhidong Road, Wuhan 430060, Hubei, China.
| | - Jun Chen
- Department of Radiology, Renmin Hospital of Wuhan University, No. 99, Zhang Zhidong Road, Wuhan 430060, Hubei, China.
| | - Yi Ling Zhao
- Department of Radiology, Renmin Hospital of Wuhan University, No. 99, Zhang Zhidong Road, Wuhan 430060, Hubei, China
| | - Jin Huan Liu
- Department of Radiology, Renmin Hospital of Wuhan University, No. 99, Zhang Zhidong Road, Wuhan 430060, Hubei, China
| | - Liang Zhang
- Department of Radiology, Renmin Hospital of Wuhan University, No. 99, Zhang Zhidong Road, Wuhan 430060, Hubei, China
| | - Chang Sheng Liu
- Department of Radiology, Renmin Hospital of Wuhan University, No. 99, Zhang Zhidong Road, Wuhan 430060, Hubei, China
| | - Dongjie Huang
- Department of Radiology, Renmin Hospital of Wuhan University, No. 99, Zhang Zhidong Road, Wuhan 430060, Hubei, China
| |
Collapse
|
27
|
Tang L, Zhou XJ. Diffusion MRI of cancer: From low to high b-values. J Magn Reson Imaging 2018; 49:23-40. [PMID: 30311988 DOI: 10.1002/jmri.26293] [Citation(s) in RCA: 118] [Impact Index Per Article: 19.7] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/26/2018] [Revised: 07/20/2018] [Accepted: 07/23/2018] [Indexed: 12/14/2022] Open
Abstract
Following its success in early detection of cerebral ischemia, diffusion-weighted imaging (DWI) has been increasingly used in cancer diagnosis and treatment evaluation. These applications are propelled by the rapid development of novel diffusion models to extract biologically valuable information from diffusion-weighted MR signals, and significant advances in MR hardware that has enabled image acquisition with high b-values. This article reviews recent technical developments and clinical applications in cancer imaging using DWI, with a special emphasis on high b-value diffusion models. The article is organized in four sections. First, we provide an overview of diffusion models that are relevant to cancer imaging. The model parameters are discussed in relation to three tissue properties-cellularity, vascularity, and microstructures. An emphasis is placed on characterization of microstructural heterogeneity, given its novelty and close relevance to cancer. Second, we illustrate diffusion MR clinical applications in each of the following three categories: 1) cancer detection and diagnosis; 2) cancer grading, staging, and classification; and 3) cancer treatment response prediction and evaluation. Third, we discuss several practical issues, including selection of image acquisition parameters, reproducibility and reliability, motion management, image distortion, etc., that are commonly encountered when applying DWI to cancer in clinical settings. Lastly, we highlight a few ongoing challenges and provide some possible future directions, particularly in the area of establishing standards via well-organized multicenter clinical trials to accelerate clinical translation of advanced DWI techniques to improving cancer care on a large scale. Level of Evidence: 5 Technical Efficacy: Stage 2 J. Magn. Reson. Imaging 2019;49:23-40.
Collapse
Affiliation(s)
- Lei Tang
- Department of Radiology, Peking University Cancer Hospital & Institute, Key laboratory of Carcinogenesis and Translational Research, Beijing, China
| | - Xiaohong Joe Zhou
- Center for MR Research and Departments of Radiology, Neurosurgery, and Bioengineering, University of Illinois at Chicago, Chicago, Illinois, USA
| |
Collapse
|
28
|
Bickelhaupt S, Jaeger PF, Laun FB, Lederer W, Daniel H, Kuder TA, Wuesthof L, Paech D, Bonekamp D, Radbruch A, Delorme S, Schlemmer HP, Steudle FH, Maier-Hein KH. Radiomics Based on Adapted Diffusion Kurtosis Imaging Helps to Clarify Most Mammographic Findings Suspicious for Cancer. Radiology 2018; 287:761-770. [PMID: 29461172 DOI: 10.1148/radiol.2017170273] [Citation(s) in RCA: 67] [Impact Index Per Article: 11.2] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/09/2023]
Abstract
Purpose To evaluate a radiomics model of Breast Imaging Reporting and Data System (BI-RADS) 4 and 5 breast lesions extracted from breast-tissue-optimized kurtosis magnetic resonance (MR) imaging for lesion characterization by using a sensitivity threshold similar to that of biopsy. Materials and Methods This institutional study included 222 women at two independent study sites (site 1: training set of 95 patients; mean age ± standard deviation, 58.6 years ± 6.6; 61 malignant and 34 benign lesions; site 2: independent test set of 127 patients; mean age, 58.2 years ± 6.8; 61 malignant and 66 benign lesions). All women presented with a finding suspicious for cancer at x-ray mammography (BI-RADS 4 or 5) and an indication for biopsy. Before biopsy, diffusion-weighted MR imaging (b values, 0-1500 sec/mm2) was performed by using 1.5-T imagers from different MR imaging vendors. Lesions were segmented and voxel-based kurtosis fitting adapted to account for fat signal contamination was performed. A radiomics feature model was developed by using a random forest regressor. The fixed model was tested on an independent test set. Conventional interpretations of MR imaging were also assessed for comparison. Results The radiomics feature model reduced false-positive results from 66 to 20 (specificity 70.0% [46 of 66]) at the predefined sensitivity of greater than 98.0% [60 of 61] in the independent test set, with BI-RADS 4a and 4b lesions benefiting from the analysis (specificity 74.0%, [37 of 50]; 60.0% [nine of 15]) and BI-RADS 5 lesions showing no added benefit. The model significantly improved specificity compared with the median apparent diffusion coefficient (P < .001) and apparent kurtosis coefficient (P = .02) alone. Conventional reading of dynamic contrast material-enhanced MR imaging provided sensitivity of 91.8% (56 of 61) and a specificity of 74.2% (49 of 66). Accounting for fat signal intensity during fitting significantly improved the area under the curve of the model (P = .001). Conclusion A radiomics model based on kurtosis diffusion-weighted imaging performed by using MR imaging machines from different vendors allowed for reliable differentiation between malignant and benign breast lesions in both a training and an independent test data set. © RSNA, 2018 Online supplemental material is available for this article.
Collapse
Affiliation(s)
- Sebastian Bickelhaupt
- From the Department of Radiology (S.B., L.W., D.P., D.B., A.R., S.D., H.P.S., F.S.), Division of Medical Image Computing (P.F.J., K.H.M.H.), and Department of Medical Physics in Radiology (F.B.L., T.A.K.), German Cancer Research Center, Im Neuenheimer Feld 280, 69120 Heidelberg, Germany; Institute of Radiology, University Hospital Erlangen, Erlangen, Germany (F.B.L.); Radiological Practice at the ATOS Clinic Heidelberg, Heidelberg, Germany (W.L.); and Radiology Center Mannheim, Mannheim, Germany (H.D.)
| | - Paul Ferdinand Jaeger
- From the Department of Radiology (S.B., L.W., D.P., D.B., A.R., S.D., H.P.S., F.S.), Division of Medical Image Computing (P.F.J., K.H.M.H.), and Department of Medical Physics in Radiology (F.B.L., T.A.K.), German Cancer Research Center, Im Neuenheimer Feld 280, 69120 Heidelberg, Germany; Institute of Radiology, University Hospital Erlangen, Erlangen, Germany (F.B.L.); Radiological Practice at the ATOS Clinic Heidelberg, Heidelberg, Germany (W.L.); and Radiology Center Mannheim, Mannheim, Germany (H.D.)
| | - Frederik Bernd Laun
- From the Department of Radiology (S.B., L.W., D.P., D.B., A.R., S.D., H.P.S., F.S.), Division of Medical Image Computing (P.F.J., K.H.M.H.), and Department of Medical Physics in Radiology (F.B.L., T.A.K.), German Cancer Research Center, Im Neuenheimer Feld 280, 69120 Heidelberg, Germany; Institute of Radiology, University Hospital Erlangen, Erlangen, Germany (F.B.L.); Radiological Practice at the ATOS Clinic Heidelberg, Heidelberg, Germany (W.L.); and Radiology Center Mannheim, Mannheim, Germany (H.D.)
| | - Wolfgang Lederer
- From the Department of Radiology (S.B., L.W., D.P., D.B., A.R., S.D., H.P.S., F.S.), Division of Medical Image Computing (P.F.J., K.H.M.H.), and Department of Medical Physics in Radiology (F.B.L., T.A.K.), German Cancer Research Center, Im Neuenheimer Feld 280, 69120 Heidelberg, Germany; Institute of Radiology, University Hospital Erlangen, Erlangen, Germany (F.B.L.); Radiological Practice at the ATOS Clinic Heidelberg, Heidelberg, Germany (W.L.); and Radiology Center Mannheim, Mannheim, Germany (H.D.)
| | - Heidi Daniel
- From the Department of Radiology (S.B., L.W., D.P., D.B., A.R., S.D., H.P.S., F.S.), Division of Medical Image Computing (P.F.J., K.H.M.H.), and Department of Medical Physics in Radiology (F.B.L., T.A.K.), German Cancer Research Center, Im Neuenheimer Feld 280, 69120 Heidelberg, Germany; Institute of Radiology, University Hospital Erlangen, Erlangen, Germany (F.B.L.); Radiological Practice at the ATOS Clinic Heidelberg, Heidelberg, Germany (W.L.); and Radiology Center Mannheim, Mannheim, Germany (H.D.)
| | - Tristan Anselm Kuder
- From the Department of Radiology (S.B., L.W., D.P., D.B., A.R., S.D., H.P.S., F.S.), Division of Medical Image Computing (P.F.J., K.H.M.H.), and Department of Medical Physics in Radiology (F.B.L., T.A.K.), German Cancer Research Center, Im Neuenheimer Feld 280, 69120 Heidelberg, Germany; Institute of Radiology, University Hospital Erlangen, Erlangen, Germany (F.B.L.); Radiological Practice at the ATOS Clinic Heidelberg, Heidelberg, Germany (W.L.); and Radiology Center Mannheim, Mannheim, Germany (H.D.)
| | - Lorenz Wuesthof
- From the Department of Radiology (S.B., L.W., D.P., D.B., A.R., S.D., H.P.S., F.S.), Division of Medical Image Computing (P.F.J., K.H.M.H.), and Department of Medical Physics in Radiology (F.B.L., T.A.K.), German Cancer Research Center, Im Neuenheimer Feld 280, 69120 Heidelberg, Germany; Institute of Radiology, University Hospital Erlangen, Erlangen, Germany (F.B.L.); Radiological Practice at the ATOS Clinic Heidelberg, Heidelberg, Germany (W.L.); and Radiology Center Mannheim, Mannheim, Germany (H.D.)
| | - Daniel Paech
- From the Department of Radiology (S.B., L.W., D.P., D.B., A.R., S.D., H.P.S., F.S.), Division of Medical Image Computing (P.F.J., K.H.M.H.), and Department of Medical Physics in Radiology (F.B.L., T.A.K.), German Cancer Research Center, Im Neuenheimer Feld 280, 69120 Heidelberg, Germany; Institute of Radiology, University Hospital Erlangen, Erlangen, Germany (F.B.L.); Radiological Practice at the ATOS Clinic Heidelberg, Heidelberg, Germany (W.L.); and Radiology Center Mannheim, Mannheim, Germany (H.D.)
| | - David Bonekamp
- From the Department of Radiology (S.B., L.W., D.P., D.B., A.R., S.D., H.P.S., F.S.), Division of Medical Image Computing (P.F.J., K.H.M.H.), and Department of Medical Physics in Radiology (F.B.L., T.A.K.), German Cancer Research Center, Im Neuenheimer Feld 280, 69120 Heidelberg, Germany; Institute of Radiology, University Hospital Erlangen, Erlangen, Germany (F.B.L.); Radiological Practice at the ATOS Clinic Heidelberg, Heidelberg, Germany (W.L.); and Radiology Center Mannheim, Mannheim, Germany (H.D.)
| | - Alexander Radbruch
- From the Department of Radiology (S.B., L.W., D.P., D.B., A.R., S.D., H.P.S., F.S.), Division of Medical Image Computing (P.F.J., K.H.M.H.), and Department of Medical Physics in Radiology (F.B.L., T.A.K.), German Cancer Research Center, Im Neuenheimer Feld 280, 69120 Heidelberg, Germany; Institute of Radiology, University Hospital Erlangen, Erlangen, Germany (F.B.L.); Radiological Practice at the ATOS Clinic Heidelberg, Heidelberg, Germany (W.L.); and Radiology Center Mannheim, Mannheim, Germany (H.D.)
| | - Stefan Delorme
- From the Department of Radiology (S.B., L.W., D.P., D.B., A.R., S.D., H.P.S., F.S.), Division of Medical Image Computing (P.F.J., K.H.M.H.), and Department of Medical Physics in Radiology (F.B.L., T.A.K.), German Cancer Research Center, Im Neuenheimer Feld 280, 69120 Heidelberg, Germany; Institute of Radiology, University Hospital Erlangen, Erlangen, Germany (F.B.L.); Radiological Practice at the ATOS Clinic Heidelberg, Heidelberg, Germany (W.L.); and Radiology Center Mannheim, Mannheim, Germany (H.D.)
| | - Heinz-Peter Schlemmer
- From the Department of Radiology (S.B., L.W., D.P., D.B., A.R., S.D., H.P.S., F.S.), Division of Medical Image Computing (P.F.J., K.H.M.H.), and Department of Medical Physics in Radiology (F.B.L., T.A.K.), German Cancer Research Center, Im Neuenheimer Feld 280, 69120 Heidelberg, Germany; Institute of Radiology, University Hospital Erlangen, Erlangen, Germany (F.B.L.); Radiological Practice at the ATOS Clinic Heidelberg, Heidelberg, Germany (W.L.); and Radiology Center Mannheim, Mannheim, Germany (H.D.)
| | - Franziska Hildegard Steudle
- From the Department of Radiology (S.B., L.W., D.P., D.B., A.R., S.D., H.P.S., F.S.), Division of Medical Image Computing (P.F.J., K.H.M.H.), and Department of Medical Physics in Radiology (F.B.L., T.A.K.), German Cancer Research Center, Im Neuenheimer Feld 280, 69120 Heidelberg, Germany; Institute of Radiology, University Hospital Erlangen, Erlangen, Germany (F.B.L.); Radiological Practice at the ATOS Clinic Heidelberg, Heidelberg, Germany (W.L.); and Radiology Center Mannheim, Mannheim, Germany (H.D.)
| | - Klaus Hermann Maier-Hein
- From the Department of Radiology (S.B., L.W., D.P., D.B., A.R., S.D., H.P.S., F.S.), Division of Medical Image Computing (P.F.J., K.H.M.H.), and Department of Medical Physics in Radiology (F.B.L., T.A.K.), German Cancer Research Center, Im Neuenheimer Feld 280, 69120 Heidelberg, Germany; Institute of Radiology, University Hospital Erlangen, Erlangen, Germany (F.B.L.); Radiological Practice at the ATOS Clinic Heidelberg, Heidelberg, Germany (W.L.); and Radiology Center Mannheim, Mannheim, Germany (H.D.)
| |
Collapse
|