1
|
Mann H, Khan S, Prasad A, Bayat F, Gu J, Jackson K, Li Y, Hosseinidoust Z, Didar TF, Filipe CDM. Bacteriophage-Activated DNAzyme Hydrogels Combined with Machine Learning Enable Point-of-Use Colorimetric Detection of Escherichia coli. ADVANCED MATERIALS (DEERFIELD BEACH, FLA.) 2025; 37:e2411173. [PMID: 39588857 PMCID: PMC11756048 DOI: 10.1002/adma.202411173] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 07/30/2024] [Revised: 11/10/2024] [Indexed: 11/27/2024]
Abstract
Developing cost-effective, consumer-accessible platforms for point-of-use environmental and clinical pathogen testing is a priority, to reduce reliance on laborious, time-consuming culturing approaches. Unfortunately, a system offering ultrasensitive detection capabilities in a form that requires little auxiliary equipment or training has remained elusive. Here, a colorimetric DNAzyme-crosslinked hydrogel sensor is presented. In the presence of a target pathogen, DNAzyme cleavage results in hydrogel dissolution, yielding the release of entrapped gold nanoparticles in a manner visible to the naked eye. Recognizing that Escherichia coli holds high relevance within both environmental and clinical environments, an E. coli-responsive DNAzyme is incorporated into this platform. Through the optimization of the hydrogel polymerization process and the discovery of bacteriophage-induced DNAzyme signal amplification, 101 CFU mL-1 E. coli is detected within real-world lake water samples. Subsequent pairing with an artificial intelligence model removed ambiguity in sensor readout, offering 96% true positive and 100% true negative accuracy. Finally, high sensor specificity and stability results supported clinical use, where 100% of urine samples collected from patients with E. coli urinary tract infections are accurately identified. No false positives are observed when testing healthy samples. Ultimately, this platform stands to significantly improve population health by substantially increasing pathogen testing accessibility.
Collapse
Affiliation(s)
- Hannah Mann
- Department of Chemical EngineeringMcMaster University1280 Main Street WestHamiltonONL8S 4L8Canada
| | - Shadman Khan
- School of Biomedical EngineeringMcMaster University1280 Main Street WestHamiltonONL8S 4L8Canada
| | - Akansha Prasad
- School of Biomedical EngineeringMcMaster University1280 Main Street WestHamiltonONL8S 4L8Canada
| | - Fereshteh Bayat
- School of Biomedical EngineeringMcMaster University1280 Main Street WestHamiltonONL8S 4L8Canada
| | - Jimmy Gu
- Department of Biochemistry and Biomedical SciencesMcMaster University1280 Main Street WestHamiltonONL8S 4L8Canada
| | - Kyle Jackson
- Department of Chemical EngineeringMcMaster University1280 Main Street WestHamiltonONL8S 4L8Canada
| | - Yingfu Li
- Department of Biochemistry and Biomedical SciencesMcMaster University1280 Main Street WestHamiltonONL8S 4L8Canada
| | - Zeinab Hosseinidoust
- Department of Chemical EngineeringMcMaster University1280 Main Street WestHamiltonONL8S 4L8Canada
| | - Tohid F. Didar
- School of Biomedical EngineeringMcMaster University1280 Main Street WestHamiltonONL8S 4L8Canada
- Department of Mechanical EngineeringMcMaster UniversityHamiltonONL8S 4L7Canada
| | - Carlos D. M. Filipe
- Department of Chemical EngineeringMcMaster University1280 Main Street WestHamiltonONL8S 4L8Canada
| |
Collapse
|
2
|
Fernández Blanco A, Moreno Y, García-Hernández J, Hernández M. A Photonic Immunosensor Detection Method for Viable and Non-Viable E. coli in Water Samples. Microorganisms 2024; 12:1328. [PMID: 39065096 PMCID: PMC11278787 DOI: 10.3390/microorganisms12071328] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/30/2024] [Revised: 06/17/2024] [Accepted: 06/21/2024] [Indexed: 07/28/2024] Open
Abstract
Detection and enumeration of coliform bacteria using traditional methods and current molecular techniques against E. coli usually involve long processes with less sensitivity and specificity to distinguish between viable and non-viable bacteria for microbiological water analysis. This approach involves developing and validating an immunosensor comprising ring resonators functionalized with specific antibodies surrounded by a network of microchannels as an alternative method for detecting and indirectly enumerating Escherichia coli in samples of water for consumption. Different ELISA assays were conducted to characterize monoclonal and polyclonal antibodies selected as detection probes for specific B-galactosidase enzymes and membrane LPS antigens of E. coli. An immobilization control study was performed on silicon nitride surfaces used in the immunosensor, immobilized with the selected antibodies from the ELISA assays. The specificity of this method was confirmed by detecting as few as 10 CFU/mL of E. coli from viable and non-viable target bacteria after applying various disinfection methods to water samples intended for human consumption. The 100% detection rate and a 100 CFU/mL Limit of Quantification of the proposed method were validated through a comprehensive assessment of the immunosensor-coupled microfluidic system, involving at least 50 replicates with a concentration range of 10 to 106 CFU/mL of the target bacteria and 50 real samples contaminated with and without disinfection treatment. The correlation coefficient of around one calculated for each calibration curve obtained from the results demonstrated sensitive and rapid detection capabilities suitable for application in water resources intended for human consumption within the food industry. The biosensor was shown to provide results in less than 4 h, allowing for rapid identification of microbial contamination crucial for ensuring water monitoring related to food safety or environmental diagnosis and allowing for timely interventions to mitigate contamination risks. Indeed, the achieved setup facilitates the in situ execution of laboratory processes, allowing for the detection of both viable and non-viable bacteria, and it implies future developments of simultaneous detection of pathogens in the same contaminated sample.
Collapse
Affiliation(s)
| | - Yolanda Moreno
- Institute of Water and Environmental Engineering, Universitat Politècnica de València, 46022 Valencia, Spain
| | - Jorge García-Hernández
- Advanced Center for Food Microbiology, Biotechnology Department, Universitat Politècnica de València, 46022 Valencia, Spain; (J.G.-H.); (M.H.)
| | - Manuel Hernández
- Advanced Center for Food Microbiology, Biotechnology Department, Universitat Politècnica de València, 46022 Valencia, Spain; (J.G.-H.); (M.H.)
| |
Collapse
|
3
|
Malik S, Singh J, Saini K, Chaudhary V, Umar A, Ibrahim AA, Akbar S, Baskoutas S. Paper-based sensors: affordable, versatile, and emerging analyte detection platforms. ANALYTICAL METHODS : ADVANCING METHODS AND APPLICATIONS 2024; 16:2777-2809. [PMID: 38639474 DOI: 10.1039/d3ay02258g] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 04/20/2024]
Abstract
Paper-based sensors, often referred to as paper-based analytical devices (PADs), stand as a transformative technology in the field of analytical chemistry. They offer an affordable, versatile, and accessible solution for diverse analyte detection. These sensors harness the unique properties of paper substrates to provide a cost-effective and adaptable platform for rapid analyte detection, spanning chemical species, biomolecules, and pathogens. This review highlights the key attributes that make paper-based sensors an attractive choice for analyte detection. PADs demonstrate their versatility by accommodating a wide range of analytes, from ions and gases to proteins, nucleic acids, and more, with customizable designs for specific applications. Their user-friendly operation and minimal infrastructure requirements suit point-of-care diagnostics, environmental monitoring, food safety, and more. This review also explores various fabrication methods such as inkjet printing, wax printing, screen printing, dip coating, and photolithography. Incorporating nanomaterials and biorecognition elements promises even more sophisticated and sensitive applications.
Collapse
Affiliation(s)
- Sumit Malik
- Department of Chemistry, Maharishi Markandeshwar (Deemed to be University), Mullana, Ambala, 133203, Haryana, India.
| | - Joginder Singh
- Department of Chemistry, Maharishi Markandeshwar (Deemed to be University), Mullana, Ambala, 133203, Haryana, India.
| | - Kajal Saini
- Department of Chemistry, Maharishi Markandeshwar (Deemed to be University), Mullana, Ambala, 133203, Haryana, India.
| | - Vivek Chaudhary
- Department of Chemistry, Maharishi Markandeshwar (Deemed to be University), Mullana, Ambala, 133203, Haryana, India.
| | - Ahmad Umar
- Department of Chemistry, Faculty of Science and Arts, Promising Centre for Sensors and Electronic Devices (PCSED), Najran University, Najran-11001, Kingdom of Saudi Arabia.
- Department of Materials Science and Engineering, The Ohio State University, Columbus 43210, OH, USA
- STEM Pioneers Training Lab, Najran University, Najran 11001, Kingdom of Saudi Arabia
| | - Ahmed A Ibrahim
- Department of Chemistry, Faculty of Science and Arts, Promising Centre for Sensors and Electronic Devices (PCSED), Najran University, Najran-11001, Kingdom of Saudi Arabia.
- STEM Pioneers Training Lab, Najran University, Najran 11001, Kingdom of Saudi Arabia
| | - Sheikh Akbar
- Department of Materials Science and Engineering, The Ohio State University, Columbus 43210, OH, USA
| | | |
Collapse
|
4
|
Manzanas C, Morrison E, Kim YS, Alipanah M, Adedokun G, Jin S, Osborne TZ, Fan ZH. Molecular testing devices for on-site detection of E. coli in water samples. Sci Rep 2023; 13:4245. [PMID: 36918634 PMCID: PMC10013241 DOI: 10.1038/s41598-023-31208-4] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/09/2022] [Accepted: 03/08/2023] [Indexed: 03/16/2023] Open
Abstract
Escherichia coli (E. coli) cells are present in fecal materials that can be the main source for disease-causing agents in water. As a result, E. coli is recommended as a water quality indicator. We have developed an innovative platform to detect E. coli for monitoring water quality on-site by integrating paper-based sample preparation with nucleic acid isothermal amplification. The platform carries out bacterial lysis and DNA enrichment onto a paper pad through ball-based valves for fluid control, with no need of laboratory equipment, followed by loop-mediated isothermal amplification (LAMP) in a battery-operated coffee mug, and colorimetric detection. We have used the platform to detect E. coli in environmental water samples in about 1 h, with a limit of quantitation of 0.2 CFU/mL, and 3 copies per reaction. The platform was confirmed for detecting multiple E. coli strains, and for water samples of different salt concentrations. We validated the functions of the platform by analyzing recreational water samples collected near the Atlantic Ocean that contain different concentrations of salt and bacteria.
Collapse
Affiliation(s)
- Carlos Manzanas
- Interdisciplinary Microsystems Group, Department of Mechanical and Aerospace Engineering, University of Florida, P.O. Box 116250, Gainesville, FL, 32611, USA
| | - Elise Morrison
- Department of Environmental Engineering Sciences, University of Florida, P.O. Box 116580, Gainesville, FL, 32611, USA.
| | - Young S Kim
- Department of Molecular Genetics and Microbiology, University of Florida, PO Box 100266, Gainesville, FL, 32610, USA
| | - Morteza Alipanah
- Interdisciplinary Microsystems Group, Department of Mechanical and Aerospace Engineering, University of Florida, P.O. Box 116250, Gainesville, FL, 32611, USA
| | - George Adedokun
- Interdisciplinary Microsystems Group, Department of Mechanical and Aerospace Engineering, University of Florida, P.O. Box 116250, Gainesville, FL, 32611, USA
| | - Shouguang Jin
- Department of Molecular Genetics and Microbiology, University of Florida, PO Box 100266, Gainesville, FL, 32610, USA
| | - Todd Z Osborne
- Whitney Laboratory of Marine Bioscience, University of Florida, P.O. Box 116580, St. Augustine, FL, 32080, USA.
- Soil, Water, and Ecosystem Sciences Department, University of Florida, P.O. Box 110290, Gainesville, FL, 32611, USA.
| | - Z Hugh Fan
- Interdisciplinary Microsystems Group, Department of Mechanical and Aerospace Engineering, University of Florida, P.O. Box 116250, Gainesville, FL, 32611, USA.
- J. Crayton Pruitt Family Department of Biomedical Engineering, University of Florida, P.O. Box 116131, Gainesville, FL, 32611, USA.
| |
Collapse
|
5
|
Santos M, Mariz M, Tiago I, Martins J, Alarico S, Ferreira P. A review on urinary tract infections diagnostic methods: Laboratory-based and point-of-care approaches. J Pharm Biomed Anal 2022; 219:114889. [PMID: 35724611 DOI: 10.1016/j.jpba.2022.114889] [Citation(s) in RCA: 13] [Impact Index Per Article: 4.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/09/2022] [Revised: 05/18/2022] [Accepted: 06/11/2022] [Indexed: 02/07/2023]
Abstract
Urinary tract infections (UTIs) are among the most common infectious diseases worldwide. This type of infections can be healthcare-associated or community-acquired and affects millions of people every year. Different diagnostic procedures are available to detect pathogens in urine and they can be divided into two main categories: laboratory-based and point-of-care (POC) detection techniques. Traditional methodologies are often time-consuming, thus, achieving a rapid and accurate identification of pathogens is a challenging feature that has been pursued by many research groups and companies operating in this area. The purpose of this review is to compare and highlight advantages and disadvantages of the traditional and currently most used detection methods, as well as the emerging POC approaches and the relevant advances in on-site detection of pathogens´ mechanisms, suitable to be adapted to UTI diagnosis. Lately, the commercially available UTI self-testing kits and devices are helping in the diagnosis of urinary infections as patients or care givers are able to perform the test, easily and comfortably at home and, upon the result, decide when to attend an appointment/Urgent Health Care Unit.
Collapse
Affiliation(s)
- Marta Santos
- CIEPQPF, Chemical Engineering Department, University of Coimbra, 3030-790 Coimbra, Portugal
| | - Marcos Mariz
- CIEPQPF, Chemical Engineering Department, University of Coimbra, 3030-790 Coimbra, Portugal
| | - Igor Tiago
- CFE, Centre for Functional Ecology (CFE), Department of Life Sciences, University of Coimbra, Coimbra, Portugal
| | - Jimmy Martins
- Faculty of Medicine and Biomedical Sciences, University of Algarve, 8005-139 Faro, Portugal
| | - Susana Alarico
- CNC, Center for Neuroscience and Cell Biology, University of Coimbra, 3004-504 Coimbra, Portugal; CIBB, Centre for Innovative Biomedicine and Biotechnology, University of Coimbra, 3004-504 Coimbra, Portugal; IIIUC, Institute for Interdisciplinary Research, University of Coimbra, 3004-504 Coimbra, Portugal.
| | - Paula Ferreira
- CIEPQPF, Chemical Engineering Department, University of Coimbra, 3030-790 Coimbra, Portugal; Department of Chemical and Biological Engineering, Coimbra Institute of Engineering, 3030-199 Coimbra, Portugal.
| |
Collapse
|
6
|
Alafeef M, Dighe K, Moitra P, Pan D. Monitoring the Viral Transmission of SARS-CoV-2 in Still Waterbodies Using a Lanthanide-Doped Carbon Nanoparticle-Based Sensor Array. ACS SUSTAINABLE CHEMISTRY & ENGINEERING 2022; 10:245-258. [PMID: 35036178 PMCID: PMC8751013 DOI: 10.1021/acssuschemeng.1c06066] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 09/05/2021] [Revised: 12/13/2021] [Indexed: 05/02/2023]
Abstract
The latest epidemic of extremely infectious coronavirus disease 2019 (COVID-19) has created a significant public health concern. Despite substantial efforts to contain severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) within a specific location, shortcomings in the surveillance of predominantly asymptomatic infections constrain attempts to identify the epidemiological spread of the virus. Continuous surveillance of wastewater streams, including sewage, offers opportunities to track the spread of SARS-CoV-2, which is believed to be found in fecal waste. To demonstrate the feasibility of SARS-CoV-2 detection in wastewater systems, we herein present a novel facilely constructed fluorescence sensing array based on a panel of three different lanthanide-doped carbon nanoparticles (LnCNPs). The differential fluorescence response pattern due to the counterion-ligand interactions allowed us to employ powerful pattern recognition to effectively detect SARS-CoV-2 and differentiate it from other viruses or bacteria. The sensor results were benchmarked to the gold standard RT-qPCR, and the sensor showed excellent sensitivity (1.5 copies/μL) and a short sample-to-results time of 15 min. This differential response of the sensor array was also explained from the differential mode of binding of the LnCNPs with the surface proteins of the studied bacteria and viruses. Therefore, the developed sensor array provides a cost-effective, community diagnostic tool that could be potentially used as a novel epidemiologic surveillance approach to mitigate the spread of COVID-19.
Collapse
Affiliation(s)
- Maha Alafeef
- Bioengineering
Department, University of Illinois at Urbana-Champaign, Urbana, Illinois 61801, United States
- Biomedical
Engineering Department, Jordan University
of Science and Technology, Irbid 22110, Jordan
- Departments
of Diagnostic Radiology and Nuclear Medicine and Pediatrics, University of Maryland Baltimore, Health Sciences
Facility III, 670 W Baltimore Street, Baltimore, Maryland 21201, United
States
- Department
of Chemical, Biochemical, and Environmental Engineering, University of Maryland Baltimore County, Interdisciplinary
Health Sciences Facility, 1000 Hilltop Circle, Baltimore, Maryland 21250, United
States
| | - Ketan Dighe
- Bioengineering
Department, University of Illinois at Urbana-Champaign, Urbana, Illinois 61801, United States
- Department
of Chemical, Biochemical, and Environmental Engineering, University of Maryland Baltimore County, Interdisciplinary
Health Sciences Facility, 1000 Hilltop Circle, Baltimore, Maryland 21250, United
States
| | - Parikshit Moitra
- Departments
of Diagnostic Radiology and Nuclear Medicine and Pediatrics, University of Maryland Baltimore, Health Sciences
Facility III, 670 W Baltimore Street, Baltimore, Maryland 21201, United
States
| | - Dipanjan Pan
- Bioengineering
Department, University of Illinois at Urbana-Champaign, Urbana, Illinois 61801, United States
- Departments
of Diagnostic Radiology and Nuclear Medicine and Pediatrics, University of Maryland Baltimore, Health Sciences
Facility III, 670 W Baltimore Street, Baltimore, Maryland 21201, United
States
- Department
of Chemical, Biochemical, and Environmental Engineering, University of Maryland Baltimore County, Interdisciplinary
Health Sciences Facility, 1000 Hilltop Circle, Baltimore, Maryland 21250, United
States
| |
Collapse
|
7
|
Mashat BH, Awad MM, Amin AH, Osman YAM. Sensitivity and Reliability of Two Antibodies in Detecting E. coli in Meat and Water. ARCHIVES OF PHARMACY PRACTICE 2022. [DOI: 10.51847/dhyfesoys8] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/11/2022] Open
|
8
|
Hosseini A, Mas J. The β-galactosidase assay in perspective: Critical thoughts for biosensor development. Anal Biochem 2021; 635:114446. [PMID: 34752779 DOI: 10.1016/j.ab.2021.114446] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/25/2021] [Revised: 10/21/2021] [Accepted: 11/01/2021] [Indexed: 01/24/2023]
Abstract
Recently, the β-galactosidase assay has become a key component in the development of assays and biosensors for the detection of enterobacteria and E. coli in water quality monitoring. The assay has often performed below its maximum potential, mainly due to a poor choice of conditions. In this study we establish a set of optimal conditions and provide a rough estimate of how departure from optimal values reduces the output of the assay potentially decreasing its sensitivity. We have established that maximum response for detecting low cell concentrations requires an induction of the samples using IPTG at a concentration of 0.2 mM during 180 min. Permeabilization of the samples is mandatory as lack of it results in an almost 60% reduction in assay output. The choice of enzyme substrate is critical as different substrates yield products with different extinction coefficients or fluorescence yields. The concentration of substrate used must be high enough (around 3 to 4 times Km) to ensure that the activity measured is not substrate limited. Finally, as the color/fluorescence of the reaction products is highly dependent on pH, care must be taken to ensure that pH at the time of reading is high enough to provide maximum signal.
Collapse
Affiliation(s)
- Anahita Hosseini
- Department of Genetics and Microbiology, Universitat Autònoma de Barcelona (UAB), Bellaterra, Barcelona, Spain.
| | - Jordi Mas
- Department of Genetics and Microbiology, Universitat Autònoma de Barcelona (UAB), Bellaterra, Barcelona, Spain
| |
Collapse
|
9
|
Monitoring Approaches for Faecal Indicator Bacteria in Water: Visioning a Remote Real-Time Sensor for E. coli and Enterococci. WATER 2020. [DOI: 10.3390/w12092591] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 12/20/2022]
Abstract
A comprehensive review was conducted to assess the current state of monitoring approaches for primary faecal indicator bacteria (FIB) E. coli and enterococci. Approaches were identified and examined in relation to their accuracy, ability to provide continuous data and instantaneous detection results, cost, environmental awareness regarding necessary reagent release or other pollution sources, in situ monitoring capability, and portability. Findings showed that several methods are precise and sophisticated but cannot be performed in real-time or remotely. This is mainly due to their laboratory testing requirements, such as lengthy sample preparations, the requirement for expensive reagents, and fluorescent tags. This study determined that portable fluorescence sensing, combined with advanced modelling methods to compensate readings for environmental interferences and false positives, can lay the foundations for a hybrid FIB sensing approach, allowing remote field deployment of a fleet of networked FIB sensors that can collect high-frequency data in near real-time. Such sensors will support proactive responses to sudden harmful faecal contamination events. A method is proposed to enable the development of the visioned FIB monitoring tool.
Collapse
|
10
|
Liu Y, Chen P, Yuan S, Sun B, Sun R, Meng X. A novel method for sensitive detection of Escherichia coli O157:H7 based on an aptamer and hybridization chain reaction. ANALYTICAL METHODS : ADVANCING METHODS AND APPLICATIONS 2020; 12:3734-3740. [PMID: 32729852 DOI: 10.1039/d0ay00708k] [Citation(s) in RCA: 13] [Impact Index Per Article: 2.6] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/12/2023]
Abstract
This work developed a novel assay for the detection of Escherichia coli O157:H7 (E. coli O157:H7), which is based on the specific recognition of an aptamer (H0) for E. coli O157:H7, the signal amplification of a hybridization chain reaction (HCR) and the adsorption and quenching effect of graphene oxide (GO). The feasibility of this work was verified through control experiments. The concentration of GO, the HCR time, the concentration of H0, and the concentration of H1/H2 were optimized. A series of E. coli O157:H7 dilutions were detected under the optimal conditions, and the detection range was 2.6 × 102 to 2.6 × 108 CFU mL-1. The linear equation is y = 591.1x- 943.9, R2 = 0.995, and LOD is 5 × 101 CFU mL-1. Milk samples were used for the spike recovery experiment, and the recovery rate was 92.6-103.6%. This method shortens the detection time greatly and provides a new strategy for food safety monitoring.
Collapse
Affiliation(s)
- Yuexin Liu
- Jilin Agricultural University, College of Food Science and Engineering, Xincheng Street, Changchun, 130118, China.
| | | | | | | | | | | |
Collapse
|
11
|
Kikuchi N, May M, Zweber M, Madamba J, Stephens C, Kim U, Mobed-Miremadi M. Sustainable, Alginate-Based Sensor for Detection of Escherichia coli in Human Breast Milk. SENSORS (BASEL, SWITZERLAND) 2020; 20:E1145. [PMID: 32093069 PMCID: PMC7071128 DOI: 10.3390/s20041145] [Citation(s) in RCA: 8] [Impact Index Per Article: 1.6] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 01/20/2020] [Revised: 02/07/2020] [Accepted: 02/15/2020] [Indexed: 12/19/2022]
Abstract
There are no existing affordable diagnostics for sensitive, rapid, and on-site detection of pathogens in milk. To this end, an on-site colorimetric-based sustainable assay has been developed and optimized using an L16 (54) Taguchi design to obtain results in hours without PCR amplification. To determine the level of Escherichia coli (E. coli) contamination, after induction with 150 µL of breast milk, the B-Per bacterial protein extraction kit was added to a solution containing an alginate-based microcapsule assay. Within this 3 mm spherical novel sensor design, X-Gal (5-Bromo-4-Chloro-3-Indolyl β-d-Galactopyranoside) was entrapped at a concentration of 2 mg/mL. The outward diffusing X-Gal was cleaved by β-galactosidase from E. coli and dimerized in the solution to yield a blue color after incubation at 40 °C. Color intensity was correlated with the level of E. coli contamination using a categorical scale. After an 8 h incubation period, a continuous imaging scale based on intensity normalization was used to determine a binary lower limit of detection (LOD), which corresponded to 102 colony forming unit per mL (CFU/mL) and above. The cost of the overall assay was estimated to be $0.81 per sample, well under the $3 benchmark for state-of-the-art immune-based test kits for pathogen detection in biofluids. Considering the reported binary LOD cutoff of 102 CFU/mL and above, this proposed hydrogel-based assay is suited to meet global requirements for screening breast milk or milk for pathogenic organisms of 104 CFU/mL, with a percentage of false positives to be determined in future efforts.
Collapse
Affiliation(s)
- Nicholas Kikuchi
- Department of Bioengineering, Santa Clara University, Santa Clara, CA 95053, USA; (N.K.); (M.Z.); (J.M.)
| | - Margaret May
- Department of Bioengineering, Santa Clara University, Santa Clara, CA 95053, USA; (N.K.); (M.Z.); (J.M.)
| | - Matthew Zweber
- Department of Bioengineering, Santa Clara University, Santa Clara, CA 95053, USA; (N.K.); (M.Z.); (J.M.)
| | - Jerard Madamba
- Department of Bioengineering, Santa Clara University, Santa Clara, CA 95053, USA; (N.K.); (M.Z.); (J.M.)
| | - Craig Stephens
- Department of Biology, Santa Clara University, Santa Clara, CA 95053, USA;
| | - Unyoung Kim
- Department of Bioengineering, Santa Clara University, Santa Clara, CA 95053, USA; (N.K.); (M.Z.); (J.M.)
| | - Maryam Mobed-Miremadi
- Department of Bioengineering, Santa Clara University, Santa Clara, CA 95053, USA; (N.K.); (M.Z.); (J.M.)
| |
Collapse
|
12
|
Kumar S, Nehra M, Mehta J, Dilbaghi N, Marrazza G, Kaushik A. Point-of-Care Strategies for Detection of Waterborne Pathogens. SENSORS (BASEL, SWITZERLAND) 2019; 19:E4476. [PMID: 31623064 PMCID: PMC6833035 DOI: 10.3390/s19204476] [Citation(s) in RCA: 41] [Impact Index Per Article: 6.8] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 09/20/2019] [Revised: 10/11/2019] [Accepted: 10/13/2019] [Indexed: 12/31/2022]
Abstract
Waterborne diseases that originated due to pathogen microorganisms are emerging as a serious global health concern. Therefore, rapid, accurate, and specific detection of these microorganisms (i.e., bacteria, viruses, protozoa, and parasitic pathogens) in water resources has become a requirement of water quality assessment. Significant research has been conducted to develop rapid, efficient, scalable, and affordable sensing techniques to detect biological contaminants. State-of-the-art technology-assisted smart sensors have improved features (high sensitivity and very low detection limit) and can perform in a real-time manner. However, there is still a need to promote this area of research, keeping global aspects and demand in mind. Keeping this view, this article was designed carefully and critically to explore sensing technologies developed for the detection of biological contaminants. Advancements using paper-based assays, microfluidic platforms, and lateral flow devices are discussed in this report. The emerging recent trends, mainly point-of-care (POC) technologies, of water safety analysis are also discussed here, along with challenges and future prospective applications of these smart sensing technologies for water health diagnostics.
Collapse
Affiliation(s)
- Sandeep Kumar
- Department of Bio and Nano Technology, Guru Jambheshwar University of Science and Technology, Hisar-Haryana 125001, India.
| | - Monika Nehra
- Department of Bio and Nano Technology, Guru Jambheshwar University of Science and Technology, Hisar-Haryana 125001, India.
| | - Jyotsana Mehta
- Department of Bio and Nano Technology, Guru Jambheshwar University of Science and Technology, Hisar-Haryana 125001, India.
| | - Neeraj Dilbaghi
- Department of Bio and Nano Technology, Guru Jambheshwar University of Science and Technology, Hisar-Haryana 125001, India.
| | - Giovanna Marrazza
- Department of Chemistry "Ugo Schiff", University of Florence, Via della Lastruccia 3, 50019 Sesto Fiorentino, Florence, Italy.
| | - Ajeet Kaushik
- Department of Natural Sciences, Florida Polytechnic University, Lakeland, FL 33805-8531, USA.
| |
Collapse
|
13
|
Kim HJ, Kwon C, Lee BS, Noh H. One-step sensing of foodborne pathogenic bacteria using a 3D paper-based device. Analyst 2019; 144:2248-2255. [PMID: 30775740 DOI: 10.1039/c8an02151a] [Citation(s) in RCA: 25] [Impact Index Per Article: 4.2] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/15/2023]
Abstract
Managing food contamination from bacteria has been an ongoing issue in the public health and industrial fields. Enzymatic substrates possessing optical properties, e.g. fluorescence or color manifestation, are widely exploited in pathogenic/non-pathogenic bacteria culture methods. Recently, various chromogenic substrates have been utilized in the development of point-of-care diagnostic tools. Herein, four types of chromogenic substrates were exploited to develop paper-based sensors for major foodborne pathogens. We designed a compact sized three-dimensional paper device with a simple user interface. By inserting functional layers in the middle of multilayers, pre-lysis and pH regulation steps were excluded and the analysis time was subsequently reduced, while only one sample droplet was needed for the whole analysis process. After the enzymatic reactions had proceeded, target-specific colors appeared. When it was combined with enrichment, 101 cfu mL-1 of pathogens were successfully detected in 4-8 hours, while those in milk samples were readily sensed in 12 hours. The proposed bacteria sensor exhibited great advantages of low cost, portability and simple operation, while showing a respectable limit-of-detection as low as 101 cfu mL-1 and below. Significantly, we emphasize that it takes fewer steps than existing methods and provides a reduced analysis time owing to the layer functionalization.
Collapse
Affiliation(s)
- Hyeok Jung Kim
- Department of Optometry, Seoul National University of Science and Technology (Seoultech), 232 Gongneung-ro, Nowon-gu, Seoul 01811, Korea.
| | | | | | | |
Collapse
|
14
|
Novel sensor platform for rapid detection and quantification of coliforms on food contact surfaces. J Microbiol Methods 2018; 153:74-83. [PMID: 30240812 DOI: 10.1016/j.mimet.2018.09.009] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/10/2018] [Revised: 09/17/2018] [Accepted: 09/17/2018] [Indexed: 01/30/2023]
Abstract
In this paper, a novel sensor platform based on screen printed carbon electrode coated by graphene modified polyacrylamide gel (GR/PAAGC) was developed and implemented for sampling, detection and enumeration of coliform bacteria (coliforms) on food contact surfaces. The optimized formula of polyacrylamide (PAA) and agar-agar increased the adhesive properties of the gel, being crucial for the coliforms recovery, attached to food contact surfaces. The 6-Chloro-3-indoxyl-β-D-galactopyranoside (6-CIGP) was used as a new electrochemical reporter for β-D-galactosidase activity. The released 6,6'-Dichloro-Indigo (6-DI) was directly detected by GR/PAAGC sensor. The presence of Isopropyl-β-D-thiogalactopyranoside (IPTG) and n-Octyl-β-D-thiogalactopyranoside (OBDG) in the gel contributed to reduction of the detection time. The addition of graphene enhanced the voltammetric signal and increased the conductivity of PAA gel. The anodic and cathodic peaks of the released product were directly proportional to the concentration of coliforms. Bacterial cell concentrations ranging from 1.6log10CFU/mL to 6.6log10CFU/mL were detected. Well-shaped, sharp voltammetric curves were generated within 3 h. Redox peaks exhibited good sensitivity with detection limits (LOD) < 0.6log10CFU/mL. After series of optimization experiments, coliforms ranging from 0.6log10CFU/cm2 to 6.610CFU/cm2 on stainless steel surfaces have been detected within 30 min with a LOD of 0.1log10CFU/cm2. The developed rapid, sensitive, reproducible and specific sensor successfully applied for single detection as well as for real-time monitoring of growth of coliform bacteria on stainless steel surfaces during food processing.
Collapse
|