1
|
Tosyalı HK, Elibol FKE, Hancıoğlu S, Kaçmaz SE, Çalışkan Öİ, Tolunay T, Demir T, Okçu G. Which implant is better for the fixation of posterior wall acetabular fractures: A conventional reconstruction plate or a brand-new calcaneal plate? Injury 2024; 55:111413. [PMID: 38394707 DOI: 10.1016/j.injury.2024.111413] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 12/10/2023] [Revised: 01/18/2024] [Accepted: 01/29/2024] [Indexed: 02/25/2024]
Abstract
BACKGROUND Increased posterior wall acetabular fractures among older adults, require precise treatment to restore stability to the joint, lower the risk of degenerative arthritis, and enhance overall functional recovery. The purpose of this study was to compare the fixation stability and mechanical characteristics of calcaneal buttress plate and conventional reconstruction plate under different loading condition. METHODS Typical acetabular posterior wall fractures were created on twenty synthetic hemipelvis models. They were fixed with calcaneus plate and reconstruction plate. Dynamic and static tests were performed. Displacements of fracture line and stiffness were calculated. FINDINGS After dynamic loading, calcaneus plate fixation has significantly less displacement than the reconstruction plate on the superior posterior wall. Under static loading condition, the calcaneus plate group has significantly less displacement than the reconstruction plate group on the inferior posterior part of the fracture. The average stiffness values of the calcaneus plate group and the reconstruction plate group were 265.16±53.98 N/mm and 167.48±36.87 N/mm, respectively and a statistically significant difference was found between the two groups. INTERPRETATION The calcaneal plate group demonstrated better stability along the fracture line after dynamic and static loading conditions. Especially when the fragment was on the acetabulum's superior posterior, inferior posterior, and inferior rim, Calcaneal buttress plates offer biomechanically effective choices.
Collapse
Affiliation(s)
- Hakan Koray Tosyalı
- Department of Orthopedics and Traumatology, Celal Bayar University Faculty of Medicine, Manisa, Turkey
| | - Fatma Kübra Erbay Elibol
- Department of Biomedical Engineering, TOBB University of Economics and Technology, Ankara, Turkey.
| | - Sertan Hancıoğlu
- Department of Orthopedics and Traumatology, Celal Bayar University Faculty of Medicine, Manisa, Turkey
| | - Suat Emre Kaçmaz
- Department of Orthopedics and Traumatology, Celal Bayar University Faculty of Medicine, Manisa, Turkey
| | - Özde İrem Çalışkan
- Department of Biomedical Engineering, TOBB University of Economics and Technology, Ankara, Turkey
| | - Tolga Tolunay
- Department of Orthopedics and Traumatology, Faculty of Medicine, Gazi University, Ankara, Turkey
| | - Teyfik Demir
- Department of Mechanical Engineering, TOBB University of Economics and Technology, Ankara, Turkey
| | - Güvenir Okçu
- Department of Orthopedics and Traumatology, Celal Bayar University Faculty of Medicine, Manisa, Turkey
| |
Collapse
|
2
|
Şibar K, Alemdaroğlu KB, Elibol FKE, Çalişkan Öİ, Demir T. Talon cannulated compression device as an alternative in the fixation of acetabulum posterior column fractures: A biomechanical study. Injury 2023; 54:110964. [PMID: 37573841 DOI: 10.1016/j.injury.2023.110964] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 06/12/2023] [Revised: 07/12/2023] [Accepted: 07/26/2023] [Indexed: 08/15/2023]
Abstract
To compare the amount of displacement and rigidity at the fracture line under static & dynamic axial loading and torsional stress of conventional cannulated screw (CS), plate screw fixation including inter-fragmentary screw (PL), and talon cannulated compression device or talon screw in other words (TS) in posterior column fracture models. Synthetic hemipelvis bone models presenting a posterior column fracture were used in this study. Group PL, CS, and TS were created with ten bone models prepared for each group for dynamic and static loading tests and another ten for torsional tests. Rigidity and displacement amounts before and after loading were measured at the reference points AL, BL, and CL, located at the acetabulum's top, middle, and bottom, respectively. Torsional tests for each group were used to calculate torsional rigidity and maximum torque values. In dynamic axial loading tests, Group CS showed more displacement than PL at the BL point (p = 0,032) and Group TS at AL (p = 0,032) and CL (p = 0,004) points. In static axial loading tests, Group CS significantly displaced more than TS at AL and CL points (p = 0,05 and p = 0,014, respectively). Group PL and Group TS exhibited similar behavior in dynamic, static axial loading tests and torsional rigidity. The maximum torque that Group PL could withstand was statistically significantly higher than the other two groups (p <0,001). Talon cannulated screws had promising results in posterior column fractures of the acetabulum, which may decline the need for open surgery for stable fixation.
Collapse
Affiliation(s)
- Kemal Şibar
- SBÜ Ankara Training and Research Hospital, Ankara, Turkey.
| | | | | | | | | |
Collapse
|
3
|
Xu B, Liu D, Liu W, Long G, Liu W, Wu Y, He X, Shen Y, Jiang P, Yin M, Fan Y, Shen H, Shi L, Zhang Q, Xue W, Jin C, Chen Z, Chen B, Li J, Hu Y, Li X, Xiao Z, Zhao Y, Dai J. Engineered human spinal cord-like tissues with dorsal and ventral neuronal progenitors for spinal cord injury repair in rats and monkeys. Bioact Mater 2023; 27:125-137. [PMID: 37064803 PMCID: PMC10090126 DOI: 10.1016/j.bioactmat.2023.03.015] [Citation(s) in RCA: 5] [Impact Index Per Article: 5.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/12/2022] [Revised: 03/05/2023] [Accepted: 03/21/2023] [Indexed: 03/31/2023] Open
Abstract
Transplanting human neural progenitor cells is a promising method of replenishing the lost neurons after spinal cord injury (SCI), but differentiating neural progenitor cells into the diverse types of mature functional spinal cord neurons in vivo is challenging. In this study, engineered human embryonic spinal cord-like tissues with dorsal and ventral neuronal characters (DV-SC) were generated by inducing human neural progenitor cells (hscNPCs) to differentiate into various types of dorsal and ventral neuronal cells on collagen scaffold in vitro. Transplantation of DV-SC into complete SCI models in rats and monkeys showed better therapeutic effects than undifferentiated hscNPCs, including pronounced cell survival and maturation. DV-SC formed a targeted connection with the host's ascending and descending axons, partially restored interrupted neural circuits, and improved motor evoked potentials and the hindlimb function of animals with SCI. This suggests that the transplantation of pre-differentiated hscNPCs with spinal cord dorsal and ventral neuronal characteristics could be a promising strategy for SCI repair.
Collapse
|
4
|
Li M, Deng J, Li J, Li Z, Zhang H, Zhao Y, Zhang L, Tang P. A Novel Anatomical Locking Guide Plate for Treating Acetabular Transverse Posterior Wall Fracture: A Finite Element Analysis Study. Orthop Surg 2022; 14:2648-2656. [PMID: 36000214 PMCID: PMC9531056 DOI: 10.1111/os.13414] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 11/23/2021] [Revised: 06/12/2022] [Accepted: 06/26/2022] [Indexed: 11/25/2022] Open
Abstract
OBJECTIVE To improve the treatment of the acetabular transverse posterior wall fracture (ATPWF), a novel anatomical locking guidance plate (NALGP) was designed and compared with traditional fixations using finite element analysis. METHODS The ATPWF model was constructed using the three-dimensional finite element model of the half pelvis via the Mimics software and three internal devices were used to fix this model: the posterior-column locking plate with anterior-column screws (PCLP), double-column locking plates (DCLP), and NALGP. Next, mesh division was conducted by solid 187 tetrahedral elements in the workbench software. After defining the boundary condition and material properties, each assembly model was loaded in an increasing manner with a downward vertical force of 200, 400, and 600 N, respectively. The loading force was directed at 45 degrees upward in the coronal plane and 25 degrees backward in the sagittal plane. Finally, the stress distribution and stress peak of plates and screws were measured and evaluated, and the displacement of fracture fragments under different loading force was assessed among the three groups. RESULTS For stress distribution, it was found that the stress mainly acted on the posterior-column plate, especially concentrated at the middle and lower section of the plate in all three groups after fixation on the ATPWF. In addition, most stresses of screws appeared on the lag screws instead of the common screws. The common screws in the NALGP group experienced larger stresses under all loading force, while those in the DCLP group withstood less stresses compared to those in the PCLP group. For the displacement of fracture fragments, the NALGP group were found to have less fracture fragment displacements than the PCLP group, but had comparable results to DCLP at both the transverse fracture and the posterior wall fracture sites. CONCLUSION The newly-designed fixation device showed superiorities on fracture stabilization over PCLP, but had comparable stability to DCLP. This suggests that the DCLP might be unnecessary for treating ATPWF in some instances because it might cause bigger surgical trauma and blood loss.
Collapse
Affiliation(s)
- Ming Li
- Department of OrthopaedicsChinese PLA General HospitalBeijingChina
- National Clinical Research Center for OrthopedicsSports Medicine and RehabilitationBeijingChina
| | - Junhao Deng
- Department of OrthopaedicsChinese PLA General HospitalBeijingChina
- National Clinical Research Center for OrthopedicsSports Medicine and RehabilitationBeijingChina
- Medical School of Chinese PLABeijingChina
| | - Jiantao Li
- Department of OrthopaedicsChinese PLA General HospitalBeijingChina
- National Clinical Research Center for OrthopedicsSports Medicine and RehabilitationBeijingChina
| | - Zhirui Li
- Department of OrthopaedicsChinese PLA General HospitalBeijingChina
- National Clinical Research Center for OrthopedicsSports Medicine and RehabilitationBeijingChina
| | - Hao Zhang
- Department of OrthopaedicsChinese PLA General HospitalBeijingChina
- National Clinical Research Center for OrthopedicsSports Medicine and RehabilitationBeijingChina
| | - Yanpeng Zhao
- Department of OrthopaedicsChinese PLA General HospitalBeijingChina
- National Clinical Research Center for OrthopedicsSports Medicine and RehabilitationBeijingChina
| | - Licheng Zhang
- Department of OrthopaedicsChinese PLA General HospitalBeijingChina
- National Clinical Research Center for OrthopedicsSports Medicine and RehabilitationBeijingChina
| | - Peifu Tang
- Department of OrthopaedicsChinese PLA General HospitalBeijingChina
- National Clinical Research Center for OrthopedicsSports Medicine and RehabilitationBeijingChina
| |
Collapse
|
5
|
Posterior wall fractures of the acetabulum: treatment using an anatomical plate through direct posterior approach. Arch Orthop Trauma Surg 2022:10.1007/s00402-022-04546-7. [PMID: 35852598 DOI: 10.1007/s00402-022-04546-7] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 03/14/2022] [Accepted: 07/02/2022] [Indexed: 11/27/2022]
Abstract
OBJECTIVES This study was aimed to measure the application of W-shaped acetabular angular plate (WAAP) through direct posterior approach (DPA) on the reconstruction of acetabular posterior wall fractures when compared with reconstruction plates. PATIENTS AND METHODS A retrospective study was performed on patients treated with the WAAP or reconstruction plates via the DPA. The intraoperative data of operative time, blood loss and radiation exposure times were recorded. Radiographs of the pelvis and CT scan were obtained within one week post-operation to assess the reduction quality. The clinical outcome was evaluated by the modified Merle d'Aubigne and Postel score. RESULTS From May 2016 to October 2019, a total of 41 patients with simple acetabular posterior wall fractures were included in this study, 22 from the WAAP group and 19 from the reconstruction plates group. There were no significant differences between the two group in age, gender, time from injury to operation, cause of injuries, length of incision and follow-up time (P > 0.05). In comparison with the reconstruction plates group, the average operation time of the WAAP group was significantly shorter (46.1 ± 12.7 min vs 59.2 ± 17.4 min, P < 0.05), the average radiation exposure times were significantly less (2.3 ± 0.6 vs 3.6 ± 1.0, P < 0.001), the average blood loss was significantly less (240 ± 98.9 ml vs 301.1 ± 66.6 ml, P < 0.05). According to Matta radiology criteria and the modified Merle d' Aubigne and Postel score, no significant difference was observed between the two group, as for the quality of reduction and function outcomes. CONCLUSION The application of WAAP through DPA showed satisfactory preliminary clinical outcomes, showing promise to be an alternative technique for the treatment of acetabular posterior wall fractures.
Collapse
|
6
|
Chen Z, Wu ZX, Chen G, Ou Y, Wen HJ. Oblique-ilioischial plate technique: a novel method for acetabular fractures involving low posterior column. BMC Musculoskelet Disord 2022; 23:540. [PMID: 35668428 PMCID: PMC9169395 DOI: 10.1186/s12891-022-05487-3] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 10/21/2021] [Accepted: 05/30/2022] [Indexed: 11/10/2022] Open
Abstract
Abstract
Background
Complex acetabular fractures involving the anterior and posterior columns are an intractable clinical challenge. The study investigated the safety and efficacy of oblique-ilioischial plate technique for acetabular fractures involving low posterior column.
Methods
A retrospective analysis of 18 patients operated with the oblique-ilioischial plate technique by the modified Stoppa approach (or combined with iliac fossa approach) between August 2016 and July 2021 for low posterior column acetabular fractures was conducted. The anterior column was fixed with a reconstructed plate from the iliac wing along the iliopectineal line to the pubis. The low posterior column was fixed with the novel oblique-ilioischial plate running from the ilium to the ischial ramus. Operative time, intraoperative blood loss, reduction quality, and postoperative hip function were recorded.
Results
Out of the 18 patients, 10 were male and 8 were female. The mean age was 48.6±10.2 years (range: 45–62 years); The mean interval from injury to operation was 7.2±1.4 days (range: 5–19 days); The mean operative time was 2.1±0.3 h (range: 1.0–3.2 hours); The mean intraoperative blood loss was 300±58.4 mL (range: 200–500 mL). Postoperative reduction (Matta’s criteria) was deemed as excellent (n = 9), good (n = 4), and fair (n = 5). At the final follow-up, the hip function (modified Merle d’Aubigne-Postel scale) was deemed as excellent (n = 11), good (n = 3), and fair (n = 4). The mean union time was 4.5±1.8 months (range: 3–6 months). No implant failure, infection, heterotopic ossification, or neurovascular injury were reported.
Conclusion
The oblique-ilioischial plate technique via anterior approach for acetabular fractures involving low posterior column offers reliable fixation, limited invasion, little intraoperative bleeding, and fewer complications. However, larger multicenter control studies are warranted.
Collapse
|
7
|
Toro G, Braile A, De Cicco A, Pezzella R, Ascione F, Cecere AB, Schiavone Panni A. Fragility Fractures of the Acetabulum: Current Concepts for Improving Patients' Outcomes. Indian J Orthop 2022; 56:1139-1149. [PMID: 35813545 PMCID: PMC9232661 DOI: 10.1007/s43465-022-00653-0] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 07/18/2021] [Accepted: 05/04/2022] [Indexed: 02/04/2023]
Abstract
The incidence of fragility fractures of the acetabulum (FFA) is constantly increasing. Generally, these fractures are related to a fall on the greater trochanter involving the anterior column. The management of FFA is extremely difficult considering both patients' comorbidities and poor bone quality. Both non-operative and several operative treatment protocols are available, and the choice among them is still ambiguous. The proposed surgical techniques for FFA [namely open reduction and internal fixation (ORIF), percutaneous fixation and total hip arthroplasty (THA)] are associated with a high complication rate. The treatment with the higher early mortality is the ORIF + THA, while the one with the lowest is the non-operative. However, at longer follow-up, this difference dreadfully change is becoming the opposite. Frequently ORIF, percutaneous fixation, and non-operative treatment need a subsequent re-operation through a THA. This latter could be extremely difficult, because of poor bone quality, acetabular mal union/non-union, bone gaps and hardware retention. However, the outcomes of each of the proposed treatment are mostly poor and controverted; therefore, a comprehensive patient evaluation and an accurate fracture description are required to appropriately manage acetabular fracture in the elderly.
Collapse
Affiliation(s)
- Giuseppe Toro
- grid.9841.40000 0001 2200 8888Department of Medical and Surgical Specialties and Dentistry, University of Campania “Luigi Vanvitelli”, 80138 Naples, Italy ,grid.6530.00000 0001 2300 0941Department of Clinical Sciences and Translational Medicine, University of Rome Tor Vergata, 00133 Rome, Italy
| | - Adriano Braile
- grid.9841.40000 0001 2200 8888Department of Medical and Surgical Specialties and Dentistry, University of Campania “Luigi Vanvitelli”, 80138 Naples, Italy
| | - Annalisa De Cicco
- grid.9841.40000 0001 2200 8888Department of Medical and Surgical Specialties and Dentistry, University of Campania “Luigi Vanvitelli”, 80138 Naples, Italy
| | - Raffaele Pezzella
- Unit of Orthopedics and Traumatology, AORN San Giuseppe Moscati, 83100 Avellino, Italy
| | - Francesco Ascione
- grid.461850.eDepartment of Orthopaedic and Traumatology Surgery, Ospedale Buon Consiglio Fatebenefratelli, 80123 Naples, Italy
| | - Antonio Benedetto Cecere
- grid.9841.40000 0001 2200 8888Department of Medical and Surgical Specialties and Dentistry, University of Campania “Luigi Vanvitelli”, 80138 Naples, Italy
| | - Alfredo Schiavone Panni
- grid.9841.40000 0001 2200 8888Department of Medical and Surgical Specialties and Dentistry, University of Campania “Luigi Vanvitelli”, 80138 Naples, Italy
| |
Collapse
|
8
|
Hinz N, Dehoust J, Münch M, Seide K, Barth T, Schulz AP, Frosch KH, Hartel MJ. Biomechanical analysis of fixation methods in acetabular fractures: a systematic review of test setups. Eur J Trauma Emerg Surg 2022; 48:3541-3560. [PMID: 35305114 PMCID: PMC9532317 DOI: 10.1007/s00068-022-01936-9] [Citation(s) in RCA: 5] [Impact Index Per Article: 2.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/01/2021] [Accepted: 02/20/2022] [Indexed: 11/29/2022]
Abstract
Purpose Optimal anatomical reduction and stable fixation of acetabular fractures are important in avoiding secondary dislocation and osteoarthritis. Biomechanical studies of treatment options of acetabular fractures aim to evaluate the biomechanical properties of different fixation methods. As the setup of the biomechanical test can influence the experimental results, this review aimed to analyze the characteristics, comparability and clinical implications of studies on biomechanical test setups and finite element analyses in the fixation of acetabular fractures. Methods A systematic literature research was conducted according to the PRISMA guidelines, using the PubMed/MEDLINE and Web of Science databases. 44 studies conducting biomechanical analyses of fixation of acetabular fractures were identified, which met the predefined inclusion and exclusion criteria and which were published in English between 2000 and April 16, 2021. The studies were analyzed with respect to distinct parameters, including fracture type, material of pelvis model, investigated fixation construct, loading direction, loading protocol, maximum loading force, outcome parameter and measurement method. Results In summary, there was no standardized test setup within the studies on fixation constructs for acetabular fractures. It is therefore difficult to compare the studies directly, as they employ a variety of different test parameters. Furthermore, the clinical implications of the biomechanical studies should be scrutinized, since several test parameters were not based on observations of the human physiology. Conclusion The limited comparability and restricted clinical implications should be kept in mind when interpreting the results of biomechanical studies and when designing test setups to evaluate fixation methods for acetabular fractures. Supplementary Information The online version contains supplementary material available at 10.1007/s00068-022-01936-9.
Collapse
Affiliation(s)
- Nico Hinz
- Department of Trauma Surgery, Orthopedic and Sports Traumatology, BG Hospital Hamburg, Bergedorfer Strasse 10, 21033, Hamburg, Germany
| | - Julius Dehoust
- Department of Trauma Surgery, Orthopedic and Sports Traumatology, BG Hospital Hamburg, Bergedorfer Strasse 10, 21033, Hamburg, Germany
| | - Matthias Münch
- Laboratory for Biomechanics, BG Hospital Hamburg, Bergedorfer Strasse 10, 21033, Hamburg, Germany
| | - Klaus Seide
- Department of Trauma Surgery, Orthopedic and Sports Traumatology, BG Hospital Hamburg, Bergedorfer Strasse 10, 21033, Hamburg, Germany.,Laboratory for Biomechanics, BG Hospital Hamburg, Bergedorfer Strasse 10, 21033, Hamburg, Germany
| | - Tobias Barth
- Laboratory for Biomechanics, BG Hospital Hamburg, Bergedorfer Strasse 10, 21033, Hamburg, Germany
| | - Arndt-Peter Schulz
- Department of Trauma Surgery, Orthopedic and Sports Traumatology, BG Hospital Hamburg, Bergedorfer Strasse 10, 21033, Hamburg, Germany.,Fraunhofer Research Institution for Individualized and Cell-Based Medical Engineering, Mönkhofer Weg 239 a, 23562, Lübeck, Germany
| | - Karl-Heinz Frosch
- Department of Trauma Surgery, Orthopedic and Sports Traumatology, BG Hospital Hamburg, Bergedorfer Strasse 10, 21033, Hamburg, Germany.,Department of Trauma and Orthopedic Surgery, University Medical Center Hamburg-Eppendorf, Martinistrasse 52, 20246, Hamburg, Germany
| | - Maximilian J Hartel
- Department of Trauma Surgery, Orthopedic and Sports Traumatology, BG Hospital Hamburg, Bergedorfer Strasse 10, 21033, Hamburg, Germany. .,Department of Trauma and Orthopedic Surgery, University Medical Center Hamburg-Eppendorf, Martinistrasse 52, 20246, Hamburg, Germany.
| |
Collapse
|
9
|
Ferrante H, Schemitsch EH, Zdero R, Bagheri ZS. Biomechanical analysis of fixation methods for acetabular fractures: A review. Med Eng Phys 2021; 89:51-62. [PMID: 33608125 DOI: 10.1016/j.medengphy.2021.02.002] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/17/2020] [Revised: 01/20/2021] [Accepted: 02/03/2021] [Indexed: 11/11/2022]
Abstract
Acetabular fractures are known as one of the most frequent types of pelvic fractures with growing frequency among elderly people. Because of this, it is important to establish the methods of repair that will produce optimal outcomes for fracture healing and joint remobilization. Open reduction and internal fixation are considered as the "gold standard" of acetabular fracture repair; however, to the best of authors' knowledge, there is no systematic review comparing different repair methods from biomechanical point of view. As such, in this review paper, we summarize the results of English language literature biomechanically focused on acetabular fracture fixation methods in the last thirty years with the aim to create a reference for clinical decision making. The selected literature within the review is broken down into categories based on type of fracture, i.e., simple or complex, and then further grouped based on fracture line orientation. Clinical recommendations and future research possibilities are also provided.
Collapse
Affiliation(s)
- Hannah Ferrante
- Department of Mechanical Engineering, George Mason University, 4400 University Dr, Fairfax, VA 22030, USA
| | - Emil H Schemitsch
- Department of Mechanical Engineering & Department of Surgery, London Health Science Center, Western University, 1151 Richmond St, London, ON N6A 3K7, Canada
| | - Radovan Zdero
- Department of Mechanical Engineering & Department of Surgery, London Health Science Center, Western University, 1151 Richmond St, London, ON N6A 3K7, Canada
| | - Z Shaghayegh Bagheri
- Department of Mechanical Engineering, George Mason University, 4400 University Dr, Fairfax, VA 22030, USA.
| |
Collapse
|
10
|
Huang J, Liao M, Chen X. [Application of new H-shaped anatomical titanium plate for posterior wall/posterior column acetabular fractures]. ZHONGGUO XIU FU CHONG JIAN WAI KE ZA ZHI = ZHONGGUO XIUFU CHONGJIAN WAIKE ZAZHI = CHINESE JOURNAL OF REPARATIVE AND RECONSTRUCTIVE SURGERY 2021; 35:64-69. [PMID: 33448201 DOI: 10.7507/1002-1892.202007045] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Subscribe] [Scholar Register] [Indexed: 11/03/2022]
Abstract
Objective To explore the effectiveness of a new H-shaped anatomical titanium plate in treatment of posterior wall/posterior column acetabular fractures. Methods Between March 2012 and April 2019, 46 patients with acetabular fractures involving posterior wall/posterior column were treated with the new H-shaped anatomical titanium plates. There were 28 males and 18 females. The age ranged from 20 to 70 years, with an average of 45.5 years. Among the patients, 34 cases were injured by traffic accidents and 12 cases by falling from height. The time from injury to operation ranged from 2 to 14 days, with an average of 7 days. According to Letournel-Judet classification, there were 12 cases of posterior wall fractures, 1 case of posterior column fracture, 3 cases of transverse fractures, 9 cases of transverse fractures involving posterior walls, 8 cases of posterior column and posterior wall fractures, 2 cases of anterior column and posterior semi-transverse fractures, 3 cases of T-shaped fractures, and 8 cases of double column fractures. Matta reduction standard was used to evaluate fracture reduction and Merle d'Aubign-Postel score was used to evaluate hip joint function. Results All operations were successfully completed. The time of posterior operation was 60-120 minutes, with an average of 80 minutes. The amount of intraoperative blood loss ranged from 200 to 600 mL, with an average of 300 mL. All the incisions healed by first intention and no infection, deep vein thrombosis, or sciatic nerve injury occurred. All 46 patients were followed up 6-72 months, with an average of 37 months. According to Matta reduction standard, 40 cases obtained anatomic reduction, 4 cases satisfactory reduction, 2 cases unsatisfactory reduction, and the satisfaction rate was 95.7% (44/46). All fractures healed, and the healing time was 3-6 months, with an average of 4.3 months. No internal fixation failure occurred during the follow-up. At last follow-up, the Merle d'Aubign-Postel score ranged from 6 to 18 (mean, 15.5), including 38 cases of excellent, 4 cases of good, 2 cases of fair, and 2 cases of poor, with an excellent and good rate of 91.3% (42/46). Heterotopic ossification occurred in 4 cases, traumatic arthritis in 4 cases, and osteonecrosis of femoral head in 2 cases after operation. Conclusion For acetabular fractures involving posterior wall/posterior column, the new H-shaped anatomical titanium plate can provide stable fixation, satisfactory reduction, and good recovery of hip function.
Collapse
Affiliation(s)
- Jiexin Huang
- Department of Orthopedics, Nanping First Hospital Affiliated to Fujian Medical University, Nanping Fujian, 353000, P.R.China
| | - Mingxin Liao
- Department of Orthopedics, Nanping First Hospital Affiliated to Fujian Medical University, Nanping Fujian, 353000, P.R.China
| | - Xiaojie Chen
- Department of Orthopedics, Nanping First Hospital Affiliated to Fujian Medical University, Nanping Fujian, 353000, P.R.China
| |
Collapse
|
11
|
Correction: Correction: Posterior column acetabular fracture fixation using a W-shaped angular plate: A biomechanical analysis. PLoS One 2019; 14:e0218646. [PMID: 31194848 PMCID: PMC6564843 DOI: 10.1371/journal.pone.0218646] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Download PDF] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/19/2022] Open
|
12
|
Su K, Liu S, Wu T, Yin Y, Zhang R, Li S, Zhang Y. Correction: Posterior column acetabular fracture fixation using a W-shaped angular plate: A biomechanical analysis. PLoS One 2019; 14:e0217734. [PMID: 31166972 PMCID: PMC6550398 DOI: 10.1371/journal.pone.0217734] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/19/2022] Open
Abstract
[This corrects the article DOI: 10.1371/journal.pone.0187886.].
Collapse
|
13
|
Altun G, Saka G, Demir T, Elibol FKE, Polat MO. Precontoured buttress plate vs reconstruction plate for acetabulum posterior wall fractures: A biomechanical study. World J Orthop 2019; 10:219-227. [PMID: 31149562 PMCID: PMC6533420 DOI: 10.5312/wjo.v10.i5.219] [Citation(s) in RCA: 8] [Impact Index Per Article: 1.6] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 01/19/2019] [Revised: 04/30/2019] [Accepted: 05/14/2019] [Indexed: 02/06/2023] Open
Abstract
BACKGROUND The purpose of open reduction and internal fixation of acetabulum posterior wall fractures is to restore anatomical structure and stability of the hip joint, in order to start weight bearing as soon as possible and prevent hip arthrosis; restoration of the anatomy should preserve function of the joint as well. Although “special shaped precontoured plates” have been developed in recent years for surgical treatment of this region, studies comparing the traditional plates with the newly designed precontoured plates are lacking.
AIM To evaluate the biomechanical properties of precontoured anatomic buttress and conventional curved reconstruction plates (CCRPs) for posterior wall acetabulum fracture treatment.
METHODS Twelve pelvis models were created for testing plate treatment of fracture in the posterior wall of the acetabulum. These 12 pelvis models were used to create 24 hemipelvis models (experimental) by cutting from the sagittal plane and passing over the center of gravity, after which the posterior wall acetabular fractures (of similar type and size) were created. In these experimental models, the right acetabulum was fixed with a 5-hole CCRP, while the left was fixed with a precontoured anatomic buttress plate (PABP). Samples were placed through the test device and were subjected to static load testing, with a constant testing velocity of 2 mm/min until the load reached 2.3 kN or the acetabular fixation failed. Dynamic tests were also performed with sinusoidal wave load, with a maximal load of 2.3 kN and a load ratio of 0.1.
RESULTS The average stiffness values were 460.83 ± 95.47 N/mm for the PABP and 291.99 ± 118.58 N/mm for the 5-hole CCRP. The precontoured anatomic acetabulum buttress plates had significantly higher rigidity than the CCRPs (P = 0.022). There was a statistically significant difference between the unloaded and 2.3 kN-loaded values of AL (posterosuperior fracture line vertical to the ground surface) and CL (posteroinferior fracture line vertical to the ground surface) parameters for both the PABPs and the 5-hole CCRPs (P = 0.036 and P = 0.045, respectively). According to the static tests, the amount of total displacement was significantly less in the PABPs than in the CCRPs. Comparative analysis of the displacement in the BL (posterior wall fracture line horizontal to the ground) parameter yielded no statistically significant differences between the PABP and the 5-hole CCRPs (P = 0.261).
CONCLUSION PABP provides more stable fixation in acetabulum posterior wall fractures than 5-hole CCRP, allowing for proximal or distal fracture line screw application without reshaping.
Collapse
Affiliation(s)
- Güray Altun
- Department of Orthopaedics and Traumatology, University of Health Sciences Umraniye Training and Research Hospital, Ümraniye, Istanbul 34764, Turkey
| | - Gürsel Saka
- Department of Orthopaedics and Traumatology, Intercontinental Hisar Hospital, Ümraniye, Istanbul 34768, Turkey
| | - Teyfik Demir
- Department of Mechanical Engineering, TOBB University of Economics and Technology, Çankaya, Ankara 06560, Turkey
| | - Fatma Kübra Erbay Elibol
- Department of Mechanical Engineering, TOBB University of Economics and Technology, Çankaya, Ankara 06560, Turkey
| | - Mehmet Orçun Polat
- Department of Industrial Engineering, Kadir Has University, Department of Industrial Engineering, Fatih, Istanbul 34083, Turkey
| |
Collapse
|
14
|
Zhang R, Hou Z, Zhang Y. Crescent Technique with Dual C-Shaped Reconstruction Plates for Posterior Acetabular Wall Fractures: An Invited Commentary. J INVEST SURG 2019; 33:684-686. [PMID: 30894045 DOI: 10.1080/08941939.2018.1556365] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/27/2022]
Affiliation(s)
- Ruipeng Zhang
- Department of Orthopaedic Surgery, Third Hospital of Hebei Medical University, Shijiazhuang, China.,Key Laboratory of Biomechanics of Hebei Province, Shijiazhuang, China
| | - Zhiyong Hou
- Department of Orthopaedic Surgery, Third Hospital of Hebei Medical University, Shijiazhuang, China.,Key Laboratory of Biomechanics of Hebei Province, Shijiazhuang, China
| | - Yingze Zhang
- Department of Orthopaedic Surgery, Third Hospital of Hebei Medical University, Shijiazhuang, China.,Key Laboratory of Biomechanics of Hebei Province, Shijiazhuang, China
| |
Collapse
|
15
|
Maini L, Mishra A, Agarwal G, Verma T, Sharma A, Tyagi A. 3D printing in designing of anatomical posterior column plate. J Clin Orthop Trauma 2018; 9:236-240. [PMID: 30202155 PMCID: PMC6128798 DOI: 10.1016/j.jcot.2018.07.009] [Citation(s) in RCA: 9] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 06/05/2018] [Accepted: 07/14/2018] [Indexed: 10/28/2022] Open
Abstract
BACKGROUND Acetabulum has a complex anatomy due to which anatomical acetabular plates are still under developmental phase. Although intra-operative contouring of reconstruction plate is done as a standard practice, it is associated with increased operative time and morbidity of patient. We have designed an acetabular plate for posterior fixation from experience of previous studies performed in our institute on acetabular fracture fixation which should be appropriate for most of the patient of Indian origin. Apart from avoiding intra-operative contouring of acetabular plates it also helps in preventing intra articular screw penetration. METHODS We selected five consecutive patients with acetabular fracture needed to be operated from posterior approach and designed patient specific plate template from virtual surgical planning and 3D printing. These plate templates were then matched with our acetabular plate design and were used intra-operatively. Many parameters were assessed to evaluate accuracy of our plate design in those five patients. RESULT All the plate templates appear to match our designed plate and no intra-operative contouring was required with our plate design. CONCLUSION This was a pilot study and we need a large sample size to study accuracy of our acetabular plate design which might avoid intra-operative contouring, decreasing morbidity of patient and prevent wastage of resources in pre-operative planning and computer designing.
Collapse
Affiliation(s)
| | - Abhishek Mishra
- Corresponding author. Plot no. 60, Vivek nagar colony, Nasirpur, Varanasi, Uttar Pradesh, India.
| | | | | | | | | |
Collapse
|