1
|
Ngoc LTN, Lee YC. Current Trends in RNA Virus Detection via Nucleic Acid Isothermal Amplification-Based Platforms. BIOSENSORS 2024; 14:97. [PMID: 38392016 PMCID: PMC10886876 DOI: 10.3390/bios14020097] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 12/24/2023] [Revised: 02/07/2024] [Accepted: 02/09/2024] [Indexed: 02/24/2024]
Abstract
Ribonucleic acid (RNA) viruses are one of the major classes of pathogens that cause human diseases. The conventional method to detect RNA viruses is real-time quantitative reverse transcription polymerase chain reaction (qRT-PCR), but it has some limitations. It is expensive and time-consuming, with infrastructure and trained personnel requirements. Its high throughput requires sophisticated automation and large-scale infrastructure. Isothermal amplification methods have been explored as an alternative to address these challenges. These methods are rapid, user-friendly, low-cost, can be performed in less specialized settings, and are highly accurate for detecting RNA viruses. Microfluidic technology provides an ideal platform for performing virus diagnostic tests, including sample preparation, immunoassays, and nucleic acid-based assays. Among these techniques, nucleic acid isothermal amplification methods have been widely integrated with microfluidic platforms for RNA virus detection owing to their simplicity, sensitivity, selectivity, and short analysis time. This review summarizes some common isothermal amplification methods for RNA viruses. It also describes commercialized devices and kits that use isothermal amplification techniques for SARS-CoV-2 detection. Furthermore, the most recent applications of isothermal amplification-based microfluidic platforms for RNA virus detection are discussed in this article.
Collapse
Affiliation(s)
- Le Thi Nhu Ngoc
- Department of Nano Science and Technology Convergence, Gachon University, 1342 Seongnam-Daero, Sujeong-gu, Seongnam-si 13120, Gyeonggi-do, Republic of Korea
| | - Young-Chul Lee
- Department of BioNano Technology, Gachon University, 1342 Seongnam-daero, Sujeong-gu, Seongnam-si 13120, Gyeonggi-do, Republic of Korea
| |
Collapse
|
2
|
Liu X, Zhou X, Li X, Wei Y, Wang T, Liu S, Yang H, Sun X. Saliva Analysis Based on Microfluidics: Focusing the Wide Spectrum of Target Analyte. Crit Rev Anal Chem 2023:1-23. [PMID: 38039145 DOI: 10.1080/10408347.2023.2287656] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/03/2023]
Abstract
Saliva is one of the most critical human body fluids that can reflect the state of the human body. The detection of saliva is of great significance for disease diagnosis and health monitoring. Microfluidics, characterized by microscale size and high integration, is an ideal platform for the development of rapid and low-cost disease diagnostic techniques and devices. Microfluidic-based saliva testing methods have aroused considerable interest due to the increasing need for noninvasive testing and frequent or long-term testing. This review briefly described the significance of saliva analysis and generally classified the targets in saliva detection into pathogenic microorganisms, inorganic substances, and organic substances. By using this classification as a benchmark, the state-of-the-art research results on microfluidic detection of various substances in saliva were summarized. This work also put forward the challenges and future development directions of microfluidic detection methods for saliva.
Collapse
Affiliation(s)
- Xin Liu
- Department of Respiratory Medicine, The Fourth Hospital of China Medical University, Shenyang, China
| | - Xinyue Zhou
- Department of Respiratory Medicine, The Fourth Hospital of China Medical University, Shenyang, China
| | - Xiaojia Li
- Teaching Center for Basic Medical Experiment, China Medical University, Shenyang, China
| | - Yixuan Wei
- Teaching Center for Basic Medical Experiment, China Medical University, Shenyang, China
| | - Tianlin Wang
- School of Intelligent Medicine, China Medical University, Shenyang, China
| | - Shuo Liu
- Department of Respiratory Medicine, The Fourth Hospital of China Medical University, Shenyang, China
| | - Huazhe Yang
- School of Intelligent Medicine, China Medical University, Shenyang, China
| | - Xiaoting Sun
- School of Forensic Medicine, China Medical University, Shenyang, China
| |
Collapse
|
3
|
Zhu H, Kim BJ, Spizz G, Rothrock D, Yasmin R, Arida J, Grocholl J, Montagna R, Schwartz B, Trujillo S, Almeria S. Development and Evaluation/Verification of a Fully Automated Test Platform for the Rapid Detection of Cyclospora cayetanensis in Produce Matrices. Microorganisms 2023; 11:2805. [PMID: 38004816 PMCID: PMC10673183 DOI: 10.3390/microorganisms11112805] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/02/2023] [Revised: 11/16/2023] [Accepted: 11/17/2023] [Indexed: 11/26/2023] Open
Abstract
Cyclosporiasis, caused by the coccidian parasite Cyclospora cayetanensis, has emerged as an increasing global public health concern, with the incidence of laboratory-confirmed domestically acquired cases in the US exceeding 10,000 since 2018. A recently published qPCR assay (Mit1C) based on a mitochondrial target gene showed high specificity and good sensitivity for the detection of C. cayetanensis in fresh produce. The present study shows the integration and verification of the same mitochondrial target into a fully automated and streamlined platform that performs DNA isolation, PCR, hybridization, results visualization, and reporting of results to simplify and reduce hands-on time for the detection of this parasite. By using the same primer sets for both the target of interest (i.e., Mit1C) and the internal assay control (IAC), we were able to rapidly migrate the previously developed Mit1C qPCR assay into the more streamlined and automated format Rheonix C. cayetanensisTM Assay. Once the best conditions for detection were optimized and the migration to the fully automated format was completed, we compared the performance of the automated platform against the original "bench top" Mit1C qPCR assay. The automated Rheonix C. cayetanensis Assay achieved equivalent performance characteristics as the original assay, including the same performance for both inclusion and exclusion panels, and it was able to detect as low as 5 C. cayetanensis oocysts in fresh produce while significantly reducing hands-on time. We expect that the streamlined assay can be used as a tool for outbreak and/or surveillance activities to detect the presence of C. cayetanensis in produce samples.
Collapse
Affiliation(s)
- Hui Zhu
- Rheonix, Inc., Ithaca, NY 14850, USA; (H.Z.); (B.J.K.); (G.S.); (D.R.); (R.Y.); (R.M.); (B.S.)
| | - Beum Jun Kim
- Rheonix, Inc., Ithaca, NY 14850, USA; (H.Z.); (B.J.K.); (G.S.); (D.R.); (R.Y.); (R.M.); (B.S.)
| | - Gwendolyn Spizz
- Rheonix, Inc., Ithaca, NY 14850, USA; (H.Z.); (B.J.K.); (G.S.); (D.R.); (R.Y.); (R.M.); (B.S.)
| | - Derek Rothrock
- Rheonix, Inc., Ithaca, NY 14850, USA; (H.Z.); (B.J.K.); (G.S.); (D.R.); (R.Y.); (R.M.); (B.S.)
| | - Rubina Yasmin
- Rheonix, Inc., Ithaca, NY 14850, USA; (H.Z.); (B.J.K.); (G.S.); (D.R.); (R.Y.); (R.M.); (B.S.)
| | - Joseph Arida
- Division of Virulence Assessment, Office of Applied Research and Safety Assessment, Center for Food Safety and Applied Nutrition, U.S. Food and Drug Administration, Laurel, MD 20708, USA; (J.A.); (J.G.); (S.T.)
- Joint Institute for Food Safety and Applied Nutrition, University of Maryland, College Park, MD 20742, USA
| | - John Grocholl
- Division of Virulence Assessment, Office of Applied Research and Safety Assessment, Center for Food Safety and Applied Nutrition, U.S. Food and Drug Administration, Laurel, MD 20708, USA; (J.A.); (J.G.); (S.T.)
| | - Richard Montagna
- Rheonix, Inc., Ithaca, NY 14850, USA; (H.Z.); (B.J.K.); (G.S.); (D.R.); (R.Y.); (R.M.); (B.S.)
| | - Brooke Schwartz
- Rheonix, Inc., Ithaca, NY 14850, USA; (H.Z.); (B.J.K.); (G.S.); (D.R.); (R.Y.); (R.M.); (B.S.)
| | - Socrates Trujillo
- Division of Virulence Assessment, Office of Applied Research and Safety Assessment, Center for Food Safety and Applied Nutrition, U.S. Food and Drug Administration, Laurel, MD 20708, USA; (J.A.); (J.G.); (S.T.)
| | - Sonia Almeria
- Division of Virulence Assessment, Office of Applied Research and Safety Assessment, Center for Food Safety and Applied Nutrition, U.S. Food and Drug Administration, Laurel, MD 20708, USA; (J.A.); (J.G.); (S.T.)
| |
Collapse
|
4
|
Oruganti S, Lakshmi Gundimeda S, Buddolla V, Anantha Lakshmi B, Kim YJ. Paper-based diagnostic chips for viral detection. Clin Chim Acta 2023:117413. [PMID: 37263536 DOI: 10.1016/j.cca.2023.117413] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/20/2023] [Revised: 05/18/2023] [Accepted: 05/25/2023] [Indexed: 06/03/2023]
Abstract
Viruses cause various diseases in humans, and pose serious health risks to individuals and populations worldwide. As a result, various diagnostic procedures and methods have been developed to prevent, manage, and reduce the burden of viral diseases, each with its own benefits and drawbacks. Among these, paper-based diagnostic chips are becoming increasingly common because of their speed, accuracy, convenience, and economical and environmental friendliness. These paper-based diagnostic tests have ideal point-of-care (POC) diagnostic applications, particularly in personalized healthcare. Paper-based diagnostics have emerged as innovative and low-cost solutions for diagnosing viral diseases in remote and underdeveloped regions where traditional diagnostic methods are not readily available. These tests are easy to use, require minimal equipment, and can be performed by nonspecialized personnel, making them accessible even in resource-constrained settings. In this review, we discuss recent developments in paper-based diagnostic chips, the importance of improved methods for identifying viral pathogens, drawbacks of traditional detection techniques, and challenges and prospects of paper-based diagnostic chips for the detection of viruses.
Collapse
Affiliation(s)
- Srividya Oruganti
- Dr. Buddolla's Institute of Life Sciences, Tirupati-517506, Andhra Pradesh, India
| | | | - Viswanath Buddolla
- Dr. Buddolla's Institute of Life Sciences, Tirupati-517506, Andhra Pradesh, India
| | - Buddolla Anantha Lakshmi
- Department of Electronic Engineering, Gachon University, 1342 Seongnam-Daero, Seongnam, Gyeonggi-Do 13120, Republic of Korea.
| | - Young-Joon Kim
- Department of Electronic Engineering, Gachon University, 1342 Seongnam-Daero, Seongnam, Gyeonggi-Do 13120, Republic of Korea.
| |
Collapse
|
5
|
Altindiş M, Kahraman Kilbaş EP. Managing Viral Emerging Infectious Diseases via Current and Future Molecular Diagnostics. Diagnostics (Basel) 2023; 13:diagnostics13081421. [PMID: 37189522 DOI: 10.3390/diagnostics13081421] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/29/2023] [Revised: 04/10/2023] [Accepted: 04/14/2023] [Indexed: 05/17/2023] Open
Abstract
Emerging viral infectious diseases have been a constant threat to global public health in recent times. In managing these diseases, molecular diagnostics has played a critical role. Molecular diagnostics involves the use of various technologies to detect the genetic material of various pathogens, including viruses, in clinical samples. One of the most commonly used molecular diagnostics technologies for detecting viruses is polymerase chain reaction (PCR). PCR amplifies specific regions of the viral genetic material in a sample, making it easier to detect and identify viruses. PCR is particularly useful for detecting viruses that are present in low concentrations in clinical samples, such as blood or saliva. Another technology that is becoming increasingly popular for viral diagnostics is next-generation sequencing (NGS). NGS can sequence the entire genome of a virus present in a clinical sample, providing a wealth of information about the virus, including its genetic makeup, virulence factors, and potential to cause an outbreak. NGS can also help identify mutations and discover new pathogens that could affect the efficacy of antiviral drugs and vaccines. In addition to PCR and NGS, there are other molecular diagnostics technologies that are being developed to manage emerging viral infectious diseases. One of these is CRISPR-Cas, a genome editing technology that can be used to detect and cut specific regions of viral genetic material. CRISPR-Cas can be used to develop highly specific and sensitive viral diagnostic tests, as well as to develop new antiviral therapies. In conclusion, molecular diagnostics tools are critical for managing emerging viral infectious diseases. PCR and NGS are currently the most commonly used technologies for viral diagnostics, but new technologies such as CRISPR-Cas are emerging. These technologies can help identify viral outbreaks early, track the spread of viruses, and develop effective antiviral therapies and vaccines.
Collapse
Affiliation(s)
- Mustafa Altindiş
- Medical Microbiology Department, Faculty of Medicine, Sakarya University, Sakarya 54050, Türkiye
| | - Elmas Pınar Kahraman Kilbaş
- Medical Laboratory Techniques, Vocational School of Health Services, Fenerbahce University, Istanbul 34758, Türkiye
| |
Collapse
|
6
|
Rey Gomez LM, Hirani R, Care A, Inglis DW, Wang Y. Emerging Microfluidic Devices for Sample Preparation of Undiluted Whole Blood to Enable the Detection of Biomarkers. ACS Sens 2023; 8:1404-1421. [PMID: 37011238 DOI: 10.1021/acssensors.2c02696] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 04/05/2023]
Abstract
Blood testing allows for diagnosis and monitoring of numerous conditions and illnesses; it forms an essential pillar of the health industry that continues to grow in market value. Due to the complex physical and biological nature of blood, samples must be carefully collected and prepared to obtain accurate and reliable analysis results with minimal background signal. Examples of common sample preparation steps include dilutions, plasma separation, cell lysis, and nucleic acid extraction and isolation, which are time-consuming and can introduce risks of sample cross-contamination or pathogen exposure to laboratory staff. Moreover, the reagents and equipment needed can be costly and difficult to obtain in point-of-care or resource-limited settings. Microfluidic devices can perform sample preparation steps in a simpler, faster, and more affordable manner. Devices can be carried to areas that are difficult to access or that do not have the resources necessary. Although many microfluidic devices have been developed in the last 5 years, few were designed for the use of undiluted whole blood as a starting point, which eliminates the need for blood dilution and minimizes blood sample preparation. This review will first provide a short summary on blood properties and blood samples typically used for analysis, before delving into innovative advances in microfluidic devices over the last 5 years that address the hurdles of blood sample preparation. The devices will be categorized by application and the type of blood sample used. The final section focuses on devices for the detection of intracellular nucleic acids, because these require more extensive sample preparation steps, and the challenges involved in adapting this technology and potential improvements are discussed.
Collapse
Affiliation(s)
| | - Rena Hirani
- Australian Red Cross Lifeblood, Sydney, New South Wales 2015, Australia
| | - Andrew Care
- School of Life Sciences, University of Technology Sydney, Ultimo, New South Wales 2007, Australia
| | - David W Inglis
- School of Engineering, Faculty of Science and Engineering and △School of Natural Sciences, Faculty of Science and Engineering, Macquarie University, Sydney, New South Wales 2109, Australia
| | | |
Collapse
|
7
|
Pittman TW, Decsi DB, Punyadeera C, Henry CS. Saliva-based microfluidic point-of-care diagnostic. Theranostics 2023; 13:1091-1108. [PMID: 36793864 PMCID: PMC9925318 DOI: 10.7150/thno.78872] [Citation(s) in RCA: 23] [Impact Index Per Article: 23.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/13/2022] [Accepted: 01/11/2023] [Indexed: 02/04/2023] Open
Abstract
There has been a long-standing interest in point-of-care (POC) diagnostics as a tool to improve patient care because it can provide rapid, actionable results near the patient. Some of the successful examples of POC testing include lateral flow assays, urine dipsticks, and glucometers. Unfortunately, POC analysis is somewhat limited by the ability to manufacture simple devices to selectively measure disease specific biomarkers and the need for invasive biological sampling. Next generation POCs are being developed that make use of microfluidic devices to detect biomarkers in biological fluids in a non-invasive manner, addressing the above-mentioned limitations. Microfluidic devices are desirable because they can provide the ability to perform additional sample processing steps not available in existing commercial diagnostics. As a result, they can provide more sensitive and selective analysis. While most POC methods make use of blood or urine as a sample matrix, there has been a growing push to use saliva as a diagnostic medium. Saliva represents an ideal non-invasive biofluid for detecting biomarkers because it is readily available in large quantities and analyte levels reflect those in blood. However, using saliva in microfluidic devices for POC diagnostics is a relatively new and an emerging field. The overarching aim of this review is to provide an update on recent literature focused on the use of saliva as a biological sample matrix in microfluidic devices. We will first cover the characteristics of saliva as a sample medium and then review microfluidic devices that are developed for the analysis of salivary biomarkers.
Collapse
Affiliation(s)
- Trey W Pittman
- Department of Chemistry, Colorado State University, Fort Collins, Colorado 80523, USA
| | - Daniel Balazs Decsi
- Centre for Biomedical Technologies, School of Biomedical Sciences, Faculty of Health, QUT.,Griffith Institute for Drug Discover, Griffith University, Nathan, Australia
| | - Chamindie Punyadeera
- Griffith Institute for Drug Discover, Griffith University, Nathan, Australia.,Menzies Health Institute, Griffith University, Gold Coast, Australia.,Translational Research Institute, Woolloongabba, Australia
| | - Charles S Henry
- Department of Chemistry, Colorado State University, Fort Collins, Colorado 80523, USA.,Metallurgy and Materials Science Research Institute, Chulalongkorn University, Soi Chula 12, Phayathai Rd., Pathumwan, Bangkok 10330, Thailand
| |
Collapse
|
8
|
Surti PV, Kim MW, Phan LMT, Kailasa SK, Mungray AK, Park JP, Park TJ. Progress on dot-blot assay as a promising analytical tool: Detection from molecules to cells. Trends Analyt Chem 2022. [DOI: 10.1016/j.trac.2022.116736] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/08/2023]
|
9
|
Jankelow AM, Lee H, Wang W, Hoang TH, Bacon A, Sun F, Chae S, Kindratenko V, Koprowski K, Stavins RA, Ceriani DD, Engelder ZW, King WP, Do MN, Bashir R, Valera E, Cunningham BT. Smartphone clip-on instrument and microfluidic processor for rapid sample-to-answer detection of Zika virus in whole blood using spatial RT-LAMP. Analyst 2022; 147:3838-3853. [PMID: 35726910 PMCID: PMC9399074 DOI: 10.1039/d2an00438k] [Citation(s) in RCA: 16] [Impact Index Per Article: 8.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/21/2022]
Abstract
Rapid, simple, inexpensive, accurate, and sensitive point-of-care (POC) detection of viral pathogens in bodily fluids is a vital component of controlling the spread of infectious diseases. The predominant laboratory-based methods for sample processing and nucleic acid detection face limitations that prevent them from gaining wide adoption for POC applications in low-resource settings and self-testing scenarios. Here, we report the design and characterization of an integrated system for rapid sample-to-answer detection of a viral pathogen in a droplet of whole blood comprised of a 2-stage microfluidic cartridge for sample processing and nucleic acid amplification, and a clip-on detection instrument that interfaces with the image sensor of a smartphone. The cartridge is designed to release viral RNA from Zika virus in whole blood using chemical lysis, followed by mixing with the assay buffer for performing reverse-transcriptase loop-mediated isothermal amplification (RT-LAMP) reactions in six parallel microfluidic compartments. The battery-powered handheld detection instrument uniformly heats the compartments from below, and an array of LEDs illuminates from above, while the generation of fluorescent reporters in the compartments is kinetically monitored by collecting a series of smartphone images. We characterize the assay time and detection limits for detecting Zika RNA and gamma ray-deactivated Zika virus spiked into buffer and whole blood and compare the performance of the same assay when conducted in conventional PCR tubes. Our approach for kinetic monitoring of the fluorescence-generating process in the microfluidic compartments enables spatial analysis of early fluorescent "bloom" events for positive samples, in an approach called "Spatial LAMP" (S-LAMP). We show that S-LAMP image analysis reduces the time required to designate an assay as a positive test, compared to conventional analysis of the average fluorescent intensity of the entire compartment. S-LAMP enables the RT-LAMP process to be as short as 22 minutes, resulting in a total sample-to-answer time in the range of 17-32 minutes to distinguish positive from negative samples, while demonstrating a viral RNA detection as low as 2.70 × 102 copies per μl, and a gamma-irradiated virus of 103 virus particles in a single 12.5 μl droplet blood sample.
Collapse
Affiliation(s)
- Aaron M Jankelow
- Department of Bioengineering, University of Illinois at Urbana-Champaign, Urbana, IL 61801, USA.
- Nick Holonyak Jr Micro and Nanotechnology Lab, University of Illinois at Urbana-Champaign, Urbana, IL 61801, USA
| | - Hankeun Lee
- Nick Holonyak Jr Micro and Nanotechnology Lab, University of Illinois at Urbana-Champaign, Urbana, IL 61801, USA
- Department of Electrical and Computer Engineering, University of Illinois at Urbana-Champaign, Urbana, IL 61801, USA
| | - Weijing Wang
- Nick Holonyak Jr Micro and Nanotechnology Lab, University of Illinois at Urbana-Champaign, Urbana, IL 61801, USA
- Department of Electrical and Computer Engineering, University of Illinois at Urbana-Champaign, Urbana, IL 61801, USA
| | - Trung-Hieu Hoang
- Department of Electrical and Computer Engineering, University of Illinois at Urbana-Champaign, Urbana, IL 61801, USA
| | - Amanda Bacon
- Nick Holonyak Jr Micro and Nanotechnology Lab, University of Illinois at Urbana-Champaign, Urbana, IL 61801, USA
- Department of Electrical and Computer Engineering, University of Illinois at Urbana-Champaign, Urbana, IL 61801, USA
| | - Fu Sun
- Nick Holonyak Jr Micro and Nanotechnology Lab, University of Illinois at Urbana-Champaign, Urbana, IL 61801, USA
- Department of Electrical and Computer Engineering, University of Illinois at Urbana-Champaign, Urbana, IL 61801, USA
| | - Seol Chae
- Nick Holonyak Jr Micro and Nanotechnology Lab, University of Illinois at Urbana-Champaign, Urbana, IL 61801, USA
- Department of Electrical and Computer Engineering, University of Illinois at Urbana-Champaign, Urbana, IL 61801, USA
| | - Victoria Kindratenko
- Department of Bioengineering, University of Illinois at Urbana-Champaign, Urbana, IL 61801, USA.
- Nick Holonyak Jr Micro and Nanotechnology Lab, University of Illinois at Urbana-Champaign, Urbana, IL 61801, USA
| | - Katherine Koprowski
- Department of Bioengineering, University of Illinois at Urbana-Champaign, Urbana, IL 61801, USA.
- Nick Holonyak Jr Micro and Nanotechnology Lab, University of Illinois at Urbana-Champaign, Urbana, IL 61801, USA
| | - Robert A Stavins
- Department of Mechanical Science and Engineering, University of Illinois at Urbana-Champaign, Urbana, IL 61801, USA
| | | | | | - William P King
- Nick Holonyak Jr Micro and Nanotechnology Lab, University of Illinois at Urbana-Champaign, Urbana, IL 61801, USA
- Department of Mechanical Science and Engineering, University of Illinois at Urbana-Champaign, Urbana, IL 61801, USA
| | - Minh N Do
- Department of Electrical and Computer Engineering, University of Illinois at Urbana-Champaign, Urbana, IL 61801, USA
| | - Rashid Bashir
- Department of Bioengineering, University of Illinois at Urbana-Champaign, Urbana, IL 61801, USA.
- Nick Holonyak Jr Micro and Nanotechnology Lab, University of Illinois at Urbana-Champaign, Urbana, IL 61801, USA
- Department of Electrical and Computer Engineering, University of Illinois at Urbana-Champaign, Urbana, IL 61801, USA
- Department of Mechanical Science and Engineering, University of Illinois at Urbana-Champaign, Urbana, IL 61801, USA
- Center for Genomic Diagnostics, Woese Institute for Genomic Biology, Urbana, IL 61801, USA
| | - Enrique Valera
- Department of Bioengineering, University of Illinois at Urbana-Champaign, Urbana, IL 61801, USA.
- Nick Holonyak Jr Micro and Nanotechnology Lab, University of Illinois at Urbana-Champaign, Urbana, IL 61801, USA
| | - Brian T Cunningham
- Department of Bioengineering, University of Illinois at Urbana-Champaign, Urbana, IL 61801, USA.
- Nick Holonyak Jr Micro and Nanotechnology Lab, University of Illinois at Urbana-Champaign, Urbana, IL 61801, USA
- Department of Electrical and Computer Engineering, University of Illinois at Urbana-Champaign, Urbana, IL 61801, USA
- Center for Genomic Diagnostics, Woese Institute for Genomic Biology, Urbana, IL 61801, USA
| |
Collapse
|
10
|
Abstract
Healthcare is undergoing large transformations, and it is imperative to leverage new technologies to support the advent of personalized medicine and disease prevention. It is now well accepted that the levels of certain biological molecules found in blood and other bodily fluids, as well as in exhaled breath, are an indication of the onset of many human diseases and reflect the health status of the person. Blood, urine, sweat, or saliva biomarkers can therefore serve in early diagnosis of diseases such as cancer, but also in monitoring disease progression, detecting metabolic disfunctions, and predicting response to a given therapy. For most point-of-care sensors, the requirement that patients themselves can use and apply them is crucial not only regarding the diagnostic part, but also at the sample collection level. This has stimulated the development of such diagnostic approaches for the non-invasive analysis of disease-relevant analytes. Considering these timely efforts, this review article focuses on novel, sensitive, and selective sensing systems for the detection of different endogenous target biomarkers in bodily fluids as well as in exhaled breath, which are associated with human diseases.
Collapse
|
11
|
Kumar S, Sharma S, Kumari S, Pande V, Savargaonkar D, Anvikar AR. Magnetic Multiplex Loop Mediated Isothermal Amplification (MM-LAMP) technique for simultaneous detection of dengue and chikungunya virus. J Virol Methods 2021; 300:114407. [PMID: 34896457 DOI: 10.1016/j.jviromet.2021.114407] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/09/2020] [Revised: 10/14/2021] [Accepted: 12/07/2021] [Indexed: 11/28/2022]
Abstract
Dengue and chikungunya viruses are arthropod borne virus spread through common vector instigating infection in human. There has been an increased recognition that more attention needs to be paid to similar sympotoms caused by both of the virus as they spread in the same region at same time. It warrants need of cost effective, user friendly and rapid multiplex diagnostic technique which could simultaneously diagnose and identify between two virus diseases in resource poor setting. A magnetic multiplex loop mediated isothermal amplification (MM-LAMP) technique was developed by coupling multiplex LAMP with magnetic particle-based naked eye visualization to overcome the shortcoming of simultaneous detection of both diseases. In recent years this technology has emerged as a particularly attractive candidate as amplification reaction process completes within 45 min. The first step involves multiplexing biotin and digoxigenin coated dengue and chikungunya primers respectively in LAMP reaction followed by precipitation of the amplified DNA with polyethylene glycol (PEG) buffer and finally clumping with streptavidin and anti-digoxigenin coated magnetic particle for virus discrimination and naked eye visualization. The DNA detection limit of MM LAMP visualization was 51.65 ng/μl which is comparable to the electrophoresis base UV light visualization. The results showed potential superiority over standard methods polymerase chain reaction (PCR). This current advancement empowers multiplex LAMP utility in resource limited setting without using any of the florescent dyes, turbidimeter, or the sophisticated quantitative PCR machine etc which restrict multiplex LAMP technique to laboratorial use only. We have proposed a novel method without such limitations. This technique has potential as a point of care technique for simultaneous detection of two diseases.
Collapse
Affiliation(s)
- Sandeep Kumar
- Parasite Host Biology, ICMR-National Institute of Malaria Research, Sector-8, Dwarka, New Delhi, 110077, India; Department of Biotechnology, Kumaun University, Bhimtal, Uttarakhand, 263136, India
| | - Supriya Sharma
- Parasite Host Biology, ICMR-National Institute of Malaria Research, Sector-8, Dwarka, New Delhi, 110077, India
| | - Sarita Kumari
- Parasite Host Biology, ICMR-National Institute of Malaria Research, Sector-8, Dwarka, New Delhi, 110077, India; Department of Biotechnology, Kumaun University, Bhimtal, Uttarakhand, 263136, India
| | - Veena Pande
- Department of Biotechnology, Kumaun University, Bhimtal, Uttarakhand, 263136, India
| | - Deepali Savargaonkar
- Parasite Host Biology, ICMR-National Institute of Malaria Research, Sector-8, Dwarka, New Delhi, 110077, India
| | - Anupkumar R Anvikar
- Parasite Host Biology, ICMR-National Institute of Malaria Research, Sector-8, Dwarka, New Delhi, 110077, India.
| |
Collapse
|
12
|
Chu H, Liu C, Liu J, Yang J, Li Y, Zhang X. Recent advances and challenges of biosensing in point-of-care molecular diagnosis. SENSORS AND ACTUATORS. B, CHEMICAL 2021; 348:130708. [PMID: 34511726 PMCID: PMC8424413 DOI: 10.1016/j.snb.2021.130708] [Citation(s) in RCA: 14] [Impact Index Per Article: 4.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 06/19/2021] [Revised: 08/30/2021] [Accepted: 08/31/2021] [Indexed: 05/07/2023]
Abstract
Molecular diagnosis, which plays a major role in infectious disease screening with successful understanding of the human genome, has attracted more attention because of the outbreak of COVID-19 recently. Since point-of-care testing (POCT) can expand the application of molecular diagnosis with the benefit of rapid reply, low cost, and working in decentralized environments, many researchers and commercial institutions have dedicated tremendous effort and enthusiasm to POCT-based biosensing for molecular diagnosis. In this review, we firstly summarize the state-of-the-art techniques and the construction of biosensing systems for POC molecular diagnosis. Then, the application scenarios of POCT-based biosensing for molecular diagnosis were also reviewed. Finally, several challenges and perspectives of POC biosensing for molecular diagnosis are discussed. This review is expected to help researchers deepen comprehension and make progresses in POCT-based biosensing field for molecular diagnosis applications.
Collapse
Affiliation(s)
- Hongwei Chu
- Shenzhen Key Laboratory of Flexible Printed Electronics Technology, School of Science, Harbin Institute of Technology (Shenzhen), Shenzhen, Guangdong 518055, China
| | - Conghui Liu
- College of Chemistry and Environmental Engineering, Shenzhen University, Shenzhen, Guangdong 518060, China
| | - Jinsen Liu
- Shenzhen ENCO Instrument Co., Ltd, Shenzhen 518000, China
| | - Jiao Yang
- Shenzhen Key Laboratory of Flexible Printed Electronics Technology, School of Science, Harbin Institute of Technology (Shenzhen), Shenzhen, Guangdong 518055, China
| | - Yingchun Li
- Shenzhen Key Laboratory of Flexible Printed Electronics Technology, School of Science, Harbin Institute of Technology (Shenzhen), Shenzhen, Guangdong 518055, China
| | - Xueji Zhang
- College of Chemistry and Environmental Engineering, Shenzhen University, Shenzhen, Guangdong 518060, China
| |
Collapse
|
13
|
|
14
|
Zhang X, Li G, Chen G, Zhu N, Wu D, Wu Y, James TD. Recent progresses and remaining challenges for the detection of Zika virus. Med Res Rev 2021; 41:2039-2108. [PMID: 33559917 DOI: 10.1002/med.21786] [Citation(s) in RCA: 8] [Impact Index Per Article: 2.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/22/2020] [Revised: 12/23/2020] [Accepted: 01/05/2021] [Indexed: 12/26/2022]
Abstract
Zika virus (ZIKV) has emerged as a particularly notorious mosquito-borne flavivirus, which can lead to a devastating congenital syndrome in the fetuses of pregnant mothers (e.g., microcephaly, spasticity, craniofacial disproportion, miscarriage, and ocular abnormalities) and cause the autoimmune disorder Guillain-Barre' syndrome of adults. Due to its severity and rapid dispersal over several continents, ZIKV has been acknowledged to be a global health concern by the World Health Organization. Unfortunately, the ZIKV has recently resurged in India with the potential for devastating effects. Researchers from all around the world have worked tirelessly to develop effective detection strategies and vaccines for the prevention and control of ZIKV infection. In this review, we comprehensively summarize the most recent research into ZIKV, including the structural biology and evolution, historical overview, pathogenesis, symptoms, and transmission. We then focus on the detection strategies for ZIKV, including viral isolation, serological assays, molecular assays, sensing methods, reverse transcription loop mediated isothermal amplification, transcription-mediated amplification technology, reverse transcription strand invasion based amplification, bioplasmonic paper-based device, and reverse transcription isothermal recombinase polymerase amplification. To conclude, we examine the limitations of currently available strategies for the detection of ZIKV, and outline future opportunities and research challenges.
Collapse
Affiliation(s)
- Xianlong Zhang
- School of Food and Biological Engineering, Shaanxi University of Science and Technology, Xi'an, China
| | - Guoliang Li
- School of Food and Biological Engineering, Shaanxi University of Science and Technology, Xi'an, China
| | - Guang Chen
- School of Food and Biological Engineering, Shaanxi University of Science and Technology, Xi'an, China
| | - Niu Zhu
- Department of Public Health, Xi'an Medical University, Xi'an, China
| | - Di Wu
- Institute for Global Food Security, Queen's University Belfast, Belfast, UK
| | - Yongning Wu
- NHC Key Laboratory of Food Safety Risk Assessment, Food Safety Research Unit (2019RU014) of Chinese Academy of Medical Science, China National Center for Food Safety Risk Assessment, Beijing, China
| | - Tony D James
- Department of Chemistry, University of Bath, Bath, UK.,School of Chemistry and Chemical Engineering, Henan Normal University, Xinxiang, China
| |
Collapse
|
15
|
Alam MA, Hasan MR, Anzar N, Suleman S, Narang J. Diagnostic approaches for the rapid detection of Zika virus–A review. Process Biochem 2021. [DOI: 10.1016/j.procbio.2020.11.009] [Citation(s) in RCA: 9] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 02/07/2023]
|
16
|
Azzi L, Maurino V, Baj A, Dani M, d’Aiuto A, Fasano M, Lualdi M, Sessa F, Alberio T. Diagnostic Salivary Tests for SARS-CoV-2. J Dent Res 2021; 100:115-123. [PMID: 33131360 PMCID: PMC7604673 DOI: 10.1177/0022034520969670] [Citation(s) in RCA: 45] [Impact Index Per Article: 15.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/12/2022] Open
Abstract
The diagnosis of Severe Acute Respiratory Syndrome Coronavirus 2 (SARS-CoV-2) infection relies on the detection of viral RNA by real-time reverse transcription polymerase chain reaction (rRT-PCR) performed with respiratory specimens, especially nasopharyngeal swabs. However, this procedure requires specialized medical personnel, centralized laboratory facilities, and time to provide results (from several hours up to 1 d). In addition, there is a non-negligible risk of viral transmission for the operator who performs the procedure. For these reasons, several studies have suggested the use of other body fluids, including saliva, for the detection of SARS-CoV-2. The use of saliva as a diagnostic specimen has numerous advantages: it is easily self-collected by the patient with almost no discomfort, it does not require specialized health care personnel for its management, and it reduces the risks for the operator. In the past few months, several scientific papers, media, and companies have announced the development of new salivary tests to detect SARS-CoV-2 infection. Posterior oropharyngeal saliva should be distinguished from oral saliva, since the former is a part of respiratory secretions, while the latter is produced by the salivary glands, which are outside the respiratory tract. Saliva can be analyzed through standard (rRT-PCR) or rapid molecular biology tests (direct rRT-PCR without extraction), although, in a hospital setting, these procedures may be performed only in addition to nasopharyngeal swabs to minimize the incidence of false-negative results. Conversely, the promising role of saliva in the diagnosis of SARS-CoV-2 infection is highlighted by the emergence of point-of-care technologies and, most important, point-of-need devices. Indeed, these devices can be directly used in workplaces, airports, schools, cinemas, and shopping centers. An example is the recently described Rapid Salivary Test, an antigen test based on the lateral flow assay, which detects the presence of the virus by identifying the spike protein in the saliva within a few minutes.
Collapse
Affiliation(s)
- L. Azzi
- Unit of Oral Medicine and
Pathology, ASST dei Sette Laghi–Ospedale di Circolo e Fondazione Macchi,
Department of Medicine and Surgery, University of Insubria, Varese,
Italy
| | - V. Maurino
- Unit of Oral Medicine and
Pathology, ASST dei Sette Laghi–Ospedale di Circolo e Fondazione Macchi,
Department of Medicine and Surgery, University of Insubria, Varese,
Italy
| | - A. Baj
- Laboratory of Clinical
Microbiology, ASST dei Sette Laghi–Ospedale di Circolo e Fondazione Macchi,
Department of Medicine and Surgery, University of Insubria, Varese,
Italy
| | - M. Dani
- Unit of Oral Medicine and
Pathology, ASST dei Sette Laghi–Ospedale di Circolo e Fondazione Macchi,
Department of Medicine and Surgery, University of Insubria, Varese,
Italy
| | - A. d’Aiuto
- Unit of Oral Medicine and
Pathology, ASST dei Sette Laghi–Ospedale di Circolo e Fondazione Macchi,
Department of Medicine and Surgery, University of Insubria, Varese,
Italy
| | - M. Fasano
- Laboratory of Biochemistry and
Functional Proteomics, Department of Science and High Technology, Busto
Arsizio (VA), Italy
| | - M. Lualdi
- Laboratory of Biochemistry and
Functional Proteomics, Department of Science and High Technology, Busto
Arsizio (VA), Italy
| | - F. Sessa
- Unit of Pathology, ASST dei Sette
Laghi–Ospedale di Circolo e Fondazione Macchi, Department of Medicine and
Surgery, University of Insubria, Varese, Italy
| | - T. Alberio
- Laboratory of Biochemistry and
Functional Proteomics, Department of Science and High Technology, Busto
Arsizio (VA), Italy
| |
Collapse
|
17
|
Moehling TJ, Choi G, Dugan LC, Salit M, Meagher RJ. LAMP Diagnostics at the Point-of-Care: Emerging Trends and Perspectives for the Developer Community. Expert Rev Mol Diagn 2021; 21:43-61. [PMID: 33474990 DOI: 10.1080/14737159.2021.1873769] [Citation(s) in RCA: 112] [Impact Index Per Article: 37.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/07/2023]
Abstract
Introduction: Over the past decade, loop-mediated isothermal amplification (LAMP) technology has played an important role in molecular diagnostics. Amongst numerous nucleic acid amplification assays, LAMP stands out in terms of sample-to-answer time, sensitivity, specificity, cost, robustness, and accessibility, making it ideal for field-deployable diagnostics in resource-limited regions.Areas covered: In this review, we outline the front-end LAMP design practices for point-of-care (POC) applications, including sample handling and various signal readout methodologies. Next, we explore existing LAMP technologies that have been validated with clinical samples in the field. We summarize recent work that utilizes reverse transcription (RT) LAMP to rapidly detect SARS-CoV-2 as an alternative to standard PCR protocols. Finally, we describe challenges in translating LAMP from the benchtop to the field and opportunities for future LAMP assay development and performance reporting.Expert opinion: Despite the popularity of LAMP in the academic research community and a recent surge in interest in LAMP due to the COVID-19 pandemic, there are numerous areas for improvement in the fundamental understanding of LAMP, which are needed to elevate the field of LAMP assay development and characterization.
Collapse
Affiliation(s)
- Taylor J Moehling
- Sandia National Laboratories, Biotechnology & Bioengineering Dept., Livermore, CA, USA
| | - Gihoon Choi
- Sandia National Laboratories, Biotechnology & Bioengineering Dept., Livermore, CA, USA
| | - Lawrence C Dugan
- Lawrence Livermore National Laboratory, Biosciences & Biotechnology Div., Livermore, CA, USA
| | - Marc Salit
- Joint Initiative for Metrology in Biology, SLAC National Accelerator Lab and Departments of Bioengineering and Pathology, Stanford University, Stanford, CA, USA
| | - Robert J Meagher
- Sandia National Laboratories, Biotechnology & Bioengineering Dept., Livermore, CA, USA
| |
Collapse
|
18
|
Basiri A, Heidari A, Nadi MF, Fallahy MTP, Nezamabadi SS, Sedighi M, Saghazadeh A, Rezaei N. Microfluidic devices for detection of RNA viruses. Rev Med Virol 2021; 31:1-11. [PMID: 32844526 PMCID: PMC7460878 DOI: 10.1002/rmv.2154] [Citation(s) in RCA: 66] [Impact Index Per Article: 22.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/21/2020] [Revised: 07/21/2020] [Accepted: 07/22/2020] [Indexed: 12/12/2022]
Abstract
There is a long way to go before the coronavirus disease 2019 (Covid-19) outbreak comes under control. qRT-PCR is currently used for the detection of severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2), the causative agent of Covid-19, but it is expensive, time-consuming, and not as sensitive as it should be. Finding a rapid, easy-to-use, and cheap diagnostic method is necessary to help control the current outbreak. Microfluidic systems provide a platform for many diagnostic tests, including RT-PCR, RT-LAMP, nested-PCR, nucleic acid hybridization, ELISA, fluorescence-Based Assays, rolling circle amplification, aptamers, sample preparation multiplexer (SPM), Porous Silicon Nanowire Forest, silica sol-gel coating/bonding, and CRISPR. They promise faster, cheaper, and easy-to-use methods with higher sensitivity, so microfluidic devices have a high potential to be an alternative method for the detection of viral RNA. These devices have previously been used to detect RNA viruses such as H1N1, Zika, HAV, HIV, and norovirus, with acceptable results. This paper provides an overview of microfluidic systems as diagnostic methods for RNA viruses with a focus on SARS-CoV-2.
Collapse
Affiliation(s)
- Arefeh Basiri
- Department of Biomaterials and Tissue Engineering, School of Advanced Technology in MedicineIsfahan University of Medical SciencesIsfahanIran
- Systematic Review and Meta‐analysis Expert Group (SRMEG), Universal Scientific Education and Research Network (USERN), TehranIran
| | - Arash Heidari
- Systematic Review and Meta‐analysis Expert Group (SRMEG), Universal Scientific Education and Research Network (USERN), TehranIran
- School of MedicineTehran University of Medical SciencesTehranIran
| | - Melina Farshbaf Nadi
- Systematic Review and Meta‐analysis Expert Group (SRMEG), Universal Scientific Education and Research Network (USERN), TehranIran
- School of MedicineTehran University of Medical SciencesTehranIran
| | - Mohammad Taha Pahlevan Fallahy
- Systematic Review and Meta‐analysis Expert Group (SRMEG), Universal Scientific Education and Research Network (USERN), TehranIran
- School of MedicineTehran University of Medical SciencesTehranIran
| | - Sasan Salehi Nezamabadi
- Systematic Review and Meta‐analysis Expert Group (SRMEG), Universal Scientific Education and Research Network (USERN), TehranIran
- School of MedicineTehran University of Medical SciencesTehranIran
| | - Mohammadreza Sedighi
- Systematic Review and Meta‐analysis Expert Group (SRMEG), Universal Scientific Education and Research Network (USERN), TehranIran
- School of MedicineTehran University of Medical SciencesTehranIran
| | - Amene Saghazadeh
- Systematic Review and Meta‐analysis Expert Group (SRMEG), Universal Scientific Education and Research Network (USERN), TehranIran
- Research Center for Immunodeficiencies, Children's Medical CenterTehran University of Medical SciencesTehranIran
| | - Nima Rezaei
- Research Center for Immunodeficiencies, Children's Medical CenterTehran University of Medical SciencesTehranIran
- Department of Immunology, School of MedicineTehran University of Medical SciencesTehranIran
- Network of Immunity in Infection, Malignancy and Autoimmunity (NIIMA), Universal Scientific Education and Research Network (USERN), TehranIran
| |
Collapse
|
19
|
Teoh BT, Chin KL, Samsudin NI, Loong SK, Sam SS, Tan KK, Khor CS, Abd-Jamil J, Zainal N, Wilder-Smith A, Zandi K, AbuBakar S. A reverse transcription loop-mediated isothermal amplification for broad coverage detection of Asian and African Zika virus lineages. BMC Infect Dis 2020; 20:947. [PMID: 33308203 PMCID: PMC7731766 DOI: 10.1186/s12879-020-05585-4] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/10/2020] [Accepted: 11/04/2020] [Indexed: 11/10/2022] Open
Abstract
BACKGROUND Early detection of Zika virus (ZIKV) infection during the viremia and viruria facilitates proper patient management and mosquito control measurement to prevent disease spread. Therefore, a cost-effective nucleic acid detection method for the diagnosis of ZIKV infection, especially in resource-deficient settings, is highly required. METHODS In the present study, a single-tube reverse transcription loop-mediated isothermal amplification (RT-LAMP) assay was developed for the detection of both the Asian and African-lineage ZIKV. The detection limit, strain coverage and cross-reactivity of the ZIKV RT-LAMP assay was evaluated. The sensitivity and specificity of the RT-LAMP were also evaluated using a total of 24 simulated clinical samples. The ZIKV quantitative reverse transcription-polymerase chain reaction (qRT-PCR) assay was used as the reference assay. RESULTS The detection limit of the RT-LAMP assay was 3.73 ZIKV RNA copies (probit analysis, P ≤ 0.05). The RT-LAMP assay detected the ZIKV genomes of both the Asian and African lineages without cross-reacting with other arthropod-borne viruses. The sensitivity and specificity of the RT-LAMP assay were 90% (95% CI = 59.6-98.2) and 100% (95% CI = 78.5-100.0), respectively. The RT-LAMP assay detected ZIKV genome in 9 of 24 (37.5%) of the simulated clinical samples compared to 10 of 24 (41.7%) by qRT-PCR assay with a high level of concordance (κ = 0.913, P < 0.001). CONCLUSION The RT-LAMP assay is applicable for the broad coverage detection of both the Asian and African ZIKV strains in resource-deficient settings.
Collapse
Affiliation(s)
- Boon-Teong Teoh
- Tropical Infectious Diseases Research and Education Centre (TIDREC), Universiti Malaya, Kuala Lumpur, Malaysia.
| | - Kim-Ling Chin
- Tropical Infectious Diseases Research and Education Centre (TIDREC), Universiti Malaya, Kuala Lumpur, Malaysia.,Institute for Advanced Studies (IAS), Universiti Malaya, Kuala Lumpur, Malaysia
| | - Nur-Izyan Samsudin
- Tropical Infectious Diseases Research and Education Centre (TIDREC), Universiti Malaya, Kuala Lumpur, Malaysia
| | - Shih-Keng Loong
- Tropical Infectious Diseases Research and Education Centre (TIDREC), Universiti Malaya, Kuala Lumpur, Malaysia
| | - Sing-Sin Sam
- Tropical Infectious Diseases Research and Education Centre (TIDREC), Universiti Malaya, Kuala Lumpur, Malaysia
| | - Kim-Kee Tan
- Tropical Infectious Diseases Research and Education Centre (TIDREC), Universiti Malaya, Kuala Lumpur, Malaysia
| | - Chee-Sieng Khor
- Tropical Infectious Diseases Research and Education Centre (TIDREC), Universiti Malaya, Kuala Lumpur, Malaysia
| | - Juraina Abd-Jamil
- Tropical Infectious Diseases Research and Education Centre (TIDREC), Universiti Malaya, Kuala Lumpur, Malaysia
| | - Nurhafiza Zainal
- Department of Medical Microbiology, Faculty of Medicine, Universiti Malaya, Kuala Lumpur, Malaysia
| | - Annelies Wilder-Smith
- Department of Public Health and Clinical Medicine, Epidemiology and Global Health, Umeå University, Umeå, Sweden.,Lee Kong Chian School of Medicine, Nanyang Technological University, Singapore, Republic of Singapore
| | - Keivan Zandi
- Department of Medical Microbiology, Faculty of Medicine, Universiti Malaya, Kuala Lumpur, Malaysia.,Center for AIDS Research, Laboratory of Biochemical Pharmacology, Department of Pediatrics, Emory University School of Medicine, Atlanta, GA, USA
| | - Sazaly AbuBakar
- Tropical Infectious Diseases Research and Education Centre (TIDREC), Universiti Malaya, Kuala Lumpur, Malaysia. .,Department of Medical Microbiology, Faculty of Medicine, Universiti Malaya, Kuala Lumpur, Malaysia.
| |
Collapse
|
20
|
Berkenbrock JA, Grecco-Machado R, Achenbach S. Microfluidic devices for the detection of viruses: aspects of emergency fabrication during the COVID-19 pandemic and other outbreaks. Proc Math Phys Eng Sci 2020; 476:20200398. [PMID: 33363440 PMCID: PMC7735301 DOI: 10.1098/rspa.2020.0398] [Citation(s) in RCA: 24] [Impact Index Per Article: 6.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/19/2020] [Accepted: 10/05/2020] [Indexed: 12/17/2022] Open
Abstract
Extensive testing of populations against COVID-19 has been suggested as a game-changer quest to control the spread of this contagious disease and to avoid further disruption in our social, healthcare and economical systems. Nonetheless, testing millions of people for a new virus brings about quite a few challenges. The development of effective tests for the new coronavirus has become a worldwide task that relies on recent discoveries and lessons learned from past outbreaks. In this work, we review the most recent publications on microfluidics devices for the detection of viruses. The topics of discussion include different detection approaches, methods of signalling and fabrication techniques. Besides the miniaturization of traditional benchtop detection assays, approaches such as electrochemical analyses, field-effect transistors and resistive pulse sensors are considered. For emergency fabrication of quick test kits, the local capabilities must be evaluated, and the joint work of universities, industries, and governments seems to be an unequivocal necessity.
Collapse
Affiliation(s)
- José Alvim Berkenbrock
- Department of Electrical and Computer Engineering, University of Saskatchewan, Saskatoon, SK, Canada
| | - Rafaela Grecco-Machado
- Department of Anatomy, Physiology and Pharmacology, University of Saskatchewan, Saskatoon, SK, Canada
| | - Sven Achenbach
- Department of Electrical and Computer Engineering, University of Saskatchewan, Saskatoon, SK, Canada
| |
Collapse
|
21
|
Reta DH, Tessema TS, Ashenef AS, Desta AF, Labisso WL, Gizaw ST, Abay SM, Melka DS, Reta FA. Molecular and Immunological Diagnostic Techniques of Medical Viruses. Int J Microbiol 2020; 2020:8832728. [PMID: 32908530 PMCID: PMC7474384 DOI: 10.1155/2020/8832728] [Citation(s) in RCA: 21] [Impact Index Per Article: 5.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/13/2020] [Revised: 06/24/2020] [Accepted: 08/15/2020] [Indexed: 01/12/2023] Open
Abstract
Viral infections are causing serious problems in human population worldwide. The recent outbreak of coronavirus disease 2019 caused by SARS-CoV-2 is a perfect example how viral infection could pose a great threat to global public health and economic sectors. Therefore, the first step in combating viral pathogens is to get a timely and accurate diagnosis. Early and accurate detection of the viral presence in patient sample is crucial for appropriate treatment, control, and prevention of epidemics. Here, we summarize some of the molecular and immunological diagnostic approaches available for the detection of viral infections of humans. Molecular diagnostic techniques provide rapid viral detection in patient sample. They are also relatively inexpensive and highly sensitive and specific diagnostic methods. Immunological-based techniques have been extensively utilized for the detection and epidemiological studies of human viral infections. They can detect antiviral antibodies or viral antigens in clinical samples. There are several commercially available molecular and immunological diagnostic kits that facilitate the use of these methods in the majority of clinical laboratories worldwide. In developing countries including Ethiopia where most of viral infections are endemic, exposure to improved or new methods is highly limited as these methods are very costly to use and also require technical skills. Since researchers and clinicians in all corners of the globe are working hard, it is hoped that in the near future, they will develop good quality tests that can be accessible in low-income countries.
Collapse
Affiliation(s)
- Daniel Hussien Reta
- School of Veterinary Medicine, Wollo University, Dessie, Ethiopia
- Institute of Biotechnology, Addis Ababa University, Addis Ababa, Ethiopia
| | | | | | - Adey Feleke Desta
- Department of Microbial, Cellular and Molecular Biology, College of Natural and Computational Sciences, Addis Ababa University, Addis Ababa, Ethiopia
| | - Wajana Lako Labisso
- Department of Pathology, College of Health Sciences, Addis Ababa University, Addis Ababa, Ethiopia
| | - Solomon Tebeje Gizaw
- Department of Medical Biochemistry, College of Health Sciences, Addis Ababa University, Addis Ababa, Ethiopia
| | - Solomon Mequanente Abay
- Department of Pharmacology and Clinical Pharmacy, School of Pharmacy, College of Health Sciences, Addis Ababa University, Addis Ababa, Ethiopia
| | - Daniel Seifu Melka
- Department of Medical Biochemistry, College of Health Sciences, Addis Ababa University, Addis Ababa, Ethiopia
| | - Fisseha Alemu Reta
- Institute of Biotechnology, Addis Ababa University, Addis Ababa, Ethiopia
- Department of Biology, College of Natural and Computational Sciences, Jigjiga University, Jigjiga, Ethiopia
| |
Collapse
|
22
|
A need to raise the bar - A systematic review of temporal trends in diagnostics for Japanese encephalitis virus infection, and perspectives for future research. Int J Infect Dis 2020; 95:444-456. [PMID: 32205287 PMCID: PMC7294235 DOI: 10.1016/j.ijid.2020.03.039] [Citation(s) in RCA: 14] [Impact Index Per Article: 3.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/07/2020] [Revised: 03/09/2020] [Accepted: 03/15/2020] [Indexed: 12/14/2022] Open
Abstract
Japanese encephalitis virus (JEV) remains a leading cause of neurological infection in Asia. A systematic review identified 20,212 published human cases of laboratory-confirmed JEV infections from 205 studies. 15,167 (75%) of cases were confirmed with the lowest confidence diagnostic test, i.e., level 3 or 4, or level 4. Only 109 (53%) of the studies reported contemporaneous testing for dengue-specific antibodies. A fundamental pre-requisite for the control of JE is lacking — that of a simple and specific diagnostic procedure that can be adapted for point-of-care tests and readily used throughout JE endemic regions of the world.
Objective Japanese encephalitis virus infection (JE) remains a leading cause of neurological disease in Asia, mainly involving individuals living in remote areas with limited access to treatment centers and diagnostic facilities. Laboratory confirmation is fundamental for the justification and implementation of vaccination programs. We reviewed the literature on historical developments and current diagnostic capability worldwide, to identify knowledge gaps and instill urgency to address them. Methods Searches were performed in Web of Science and PubMed using the term 'Japanese encephalitis' up to 13th October 2019. Studies reporting laboratory-confirmed symptomatic JE cases in humans were included, and data on details of diagnostic tests were extracted. A JE case was classified according to confirmatory levels (Fischer et al., 2008; Campbell et al., 2011; Pearce et al., 2018; Heffelfinger et al., 2017), where level 1 represented the highest level of confidence. Findings 20,212 published JE cases were identified from 205 studies. 15,167 (75%) of these positive cases were confirmed with the lowest-confidence diagnostic tests (level 3 or 4, or level 4). Only 109 (53%) of the studies reported contemporaneous testing for dengue-specific antibodies. Conclusion A fundamental pre-requisite for the control of JEV is lacking — that of a simple and specific diagnostic procedure that can be adapted for point-of-care tests and readily used throughout JE-endemic regions of the world.
Collapse
|
23
|
Campos EVR, de Oliveira JL, Abrantes DC, Rogério CB, Bueno C, Miranda VR, Monteiro RA, Fraceto LF. Recent Developments in Nanotechnology for Detection and Control of Aedes aegypti-Borne Diseases. Front Bioeng Biotechnol 2020; 8:102. [PMID: 32154233 PMCID: PMC7047929 DOI: 10.3389/fbioe.2020.00102] [Citation(s) in RCA: 19] [Impact Index Per Article: 4.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/27/2019] [Accepted: 02/03/2020] [Indexed: 11/24/2022] Open
Abstract
Arboviruses such as yellow fever, dengue, chikungunya and zika are transmitted mainly by the mosquito vector Aedes aegypti. Especially in the tropics, inefficacy of mosquito control causes arboviruses outbreaks every year, affecting the general population with debilitating effects in infected individuals. Several strategies have been tried to control the proliferation of A. aegypti using physical, biological, and chemical control measures. Other methods are currently under research and development, amongst which the use of nanotechnology has attracted a lot of attention of the researchers in relation to the production of more effective repellents and larvicides with less toxicity, and development of rapid sensors for the detection of virus infections. In this review, the utilization of nano-based formulations on control and diagnosis of mosquito-borne diseases were discussed. We also emphasizes the need for future research for broad commercialization of nano-based formulations in world market aiming a positive impact on public health.
Collapse
Affiliation(s)
| | | | | | | | - Carolina Bueno
- São Paulo State University—UNESP, Institute of Science and Technology, Sorocaba, Brazil
| | | | | | | |
Collapse
|
24
|
Artika IM, Wiyatno A, Ma'roef CN. Pathogenic viruses: Molecular detection and characterization. INFECTION GENETICS AND EVOLUTION 2020; 81:104215. [PMID: 32006706 PMCID: PMC7106233 DOI: 10.1016/j.meegid.2020.104215] [Citation(s) in RCA: 37] [Impact Index Per Article: 9.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 09/15/2019] [Revised: 01/23/2020] [Accepted: 01/28/2020] [Indexed: 12/14/2022]
Abstract
Pathogenic viruses are viruses that can infect and replicate within human cells and cause diseases. The continuous emergence and re-emergence of pathogenic viruses has become a major threat to public health. Whenever pathogenic viruses emerge, their rapid detection is critical to enable implementation of specific control measures and the limitation of virus spread. Further molecular characterization to better understand these viruses is required for the development of diagnostic tests and countermeasures. Advances in molecular biology techniques have revolutionized the procedures for detection and characterization of pathogenic viruses. The development of PCR-based techniques together with DNA sequencing technology, have provided highly sensitive and specific methods to determine virus circulation. Pathogenic viruses potentially having global catastrophic consequences may emerge in regions where capacity for their detection and characterization is limited. Development of a local capacity to rapidly identify new viruses is therefore critical. This article reviews the molecular biology of pathogenic viruses and the basic principles of molecular techniques commonly used for their detection and characterization. The principles of good laboratory practices for handling pathogenic viruses are also discussed. This review aims at providing researchers and laboratory personnel with an overview of the molecular biology of pathogenic viruses and the principles of molecular techniques and good laboratory practices commonly implemented for their detection and characterization. The continous emergence and re-emergence of pathogenic viruses has become a major threat to public health. PCR-based techniques together with DNA sequencing technology have provided highly sensitive and specific methods to determine virus circulation. Southeast Asia is considered to be vulnerable to potential outbreaks of pathogenic viruses. A number of pathogenic viruses have been reported to circulate in this region. The 2019 novel coronavirus has also been identified in Southeast Asia. Development of local capacity to rapidly identify new viruses is very important.
Collapse
Affiliation(s)
- I Made Artika
- Biosafety Level 3 Unit, Eijkman Institute for Molecular Biology, Jalan Diponegoro 69, Jakarta 10430, Indonesia; Department of Biochemistry, Faculty of Mathematics and Natural Sciences, Bogor Agricultural University, Darmaga Campus, Bogor 16680, Indonesia.
| | - Ageng Wiyatno
- Emerging Virus Research Unit, Eijkman Institute for Molecular Biology, Jalan Diponegoro 69, Jakarta 10430, Indonesia
| | - Chairin Nisa Ma'roef
- Emerging Virus Research Unit, Eijkman Institute for Molecular Biology, Jalan Diponegoro 69, Jakarta 10430, Indonesia
| |
Collapse
|
25
|
Lopez-Jimena B, Bakheit M, Bekaert M, Harold G, Frischmann S, Fall C, Diagne CT, Faye O, Faye O, Sall AA, Weidmann M. Development and Validation of Real-Time RT-LAMP Assays for the Specific Detection of Zika Virus. Methods Mol Biol 2020; 2142:147-164. [PMID: 32367366 DOI: 10.1007/978-1-0716-0581-3_13] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 06/11/2023]
Abstract
Two one-step real-time reverse transcription loop-mediated isothermal amplification (RT-LAMP) assays for the detection of Zika virus (ZIKV) were developed, based on two different primer design approaches: (1) open source, based on a combination of sequence diversity clustering (phylogeny and principal component analysis) and LAVA algorithm, using 45 whole genome ZIKV sequences retrieved from the National Center for Biotechnology Information (NCBI) database; (2) standard software for LAMP primer design (Primer Explorer V4), using 59 sequences of the ZIKV 3' UTR. The assays were firstly evaluated with External Quality Assessment panels from INSTAND e.V. (Germany) and EVD-LabNet (The Netherlands) including 4 and 12 unknown samples, respectively, and secondly, with 9 human, mosquito, and monkey ZIKV isolates from Africa (Senegal, Ivory Coast, and Uganda) and America (Brazil). The limit of detection as determined by probit analysis was 181 molecules for both RT-LAMP assays, and 100% reproducibility in the assays was obtained for 103 molecules (4/8 repetitions were positive for 102 molecules). Both assays were specific, amplifying only ZIKV RNA and not cross-detecting other arboviruses included in this study.
Collapse
Affiliation(s)
- Benjamin Lopez-Jimena
- Institute of Aquaculture, University of Stirling, Scotland, UK.
- Centre for Diagnostics Development, LifeArc, Scotland, UK.
| | | | - Michaël Bekaert
- Institute of Aquaculture, University of Stirling, Scotland, UK
| | - Graham Harold
- Institute of Aquaculture, University of Stirling, Scotland, UK
| | | | - Cheikh Fall
- Arbovirus and Viral Haemorrhagic Fever Unit, Institut Pasteur de Dakar, Dakar, Senegal
| | - Cheikh Tidiane Diagne
- Arbovirus and Viral Haemorrhagic Fever Unit, Institut Pasteur de Dakar, Dakar, Senegal
| | - Oumar Faye
- Arbovirus and Viral Haemorrhagic Fever Unit, Institut Pasteur de Dakar, Dakar, Senegal
| | - Ousmane Faye
- Arbovirus and Viral Haemorrhagic Fever Unit, Institut Pasteur de Dakar, Dakar, Senegal
| | - Amadou Alpha Sall
- Arbovirus and Viral Haemorrhagic Fever Unit, Institut Pasteur de Dakar, Dakar, Senegal
| | | |
Collapse
|
26
|
Ozer T, Geiss BJ, Henry CS. Review-Chemical and Biological Sensors for Viral Detection. JOURNAL OF THE ELECTROCHEMICAL SOCIETY 2020; 167:037523. [PMID: 32287357 PMCID: PMC7106559 DOI: 10.1149/2.0232003jes] [Citation(s) in RCA: 79] [Impact Index Per Article: 19.8] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 10/03/2019] [Revised: 11/25/2019] [Indexed: 05/19/2023]
Abstract
Infectious diseases commonly occur in contaminated water, food, and bodily fluids and spread rapidly, resulting in death of humans and animals worldwide. Among infectious agents, viruses pose a serious threat to public health and global economy because they are often difficult to detect and their infections are hard to treat. Since it is crucial to develop rapid, accurate, cost-effective, and in-situ methods for early detection viruses, a variety of sensors have been reported so far. This review provides an overview of the recent developments in electrochemical sensors and biosensors for detecting viruses and use of these sensors on environmental, clinical and food monitoring. Electrochemical biosensors for determining viruses are divided into four main groups including nucleic acid-based, antibody-based, aptamer-based and antigen-based electrochemical biosensors. Finally, the drawbacks and advantages of each type of sensors are identified and discussed.
Collapse
Affiliation(s)
- Tugba Ozer
- Department of Chemistry, Colorado State University, USA
- Yildiz Technical University, Faculty of Chemistry-Metallurgy, Department of Bioengineering, Istanbul, Turkey
| | - Brian J Geiss
- Department of Microbiology, Immunology & Pathology, Colorado State University, USA
- School of Biomedical Engineering, Colorado State University, USA
| | - Charles S Henry
- Department of Chemistry, Colorado State University, USA
- School of Biomedical Engineering, Colorado State University, USA
| |
Collapse
|
27
|
da Silva SJR, Pardee K, Pena L. Loop-Mediated Isothermal Amplification (LAMP) for the Diagnosis of Zika Virus: A Review. Viruses 2019; 12:v12010019. [PMID: 31877989 PMCID: PMC7019470 DOI: 10.3390/v12010019] [Citation(s) in RCA: 71] [Impact Index Per Article: 14.2] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/11/2019] [Revised: 11/30/2019] [Accepted: 12/04/2019] [Indexed: 12/17/2022] Open
Abstract
The recent outbreak of Zika virus (ZIKV) in the Americas and its devastating developmental and neurological manifestations has prompted the development of field-based diagnostics that are rapid, reliable, handheld, specific, sensitive, and inexpensive. The gold standard molecular method for lab-based diagnosis of ZIKV, from either patient samples or insect vectors, is reverse transcription-quantitative polymerase chain reaction (RT-qPCR). The method, however, is costly and requires lab-based equipment and expertise, which severely limits its use as a point-of-care (POC) tool in resource-poor settings. Moreover, given the lack of antivirals or approved vaccines for ZIKV infection, a POC diagnostic test is urgently needed for the early detection of new outbreaks and to adequately manage patients. Loop-mediated isothermal amplification (LAMP) is a compelling alternative to RT-qPCR for ZIKV and other arboviruses. This low-cost molecular system can be freeze-dried for distribution and exhibits high specificity, sensitivity, and efficiency. A growing body of evidence suggests that LAMP assays can provide greater accessibility to much-needed diagnostics for ZIKV infections, especially in developing countries where the ZIKV is now endemic. This review summarizes the different LAMP methods that have been developed for the virus and summarizes their features, advantages, and limitations.
Collapse
Affiliation(s)
| | - Keith Pardee
- Leslie Dan Faculty of Pharmacy, University of Toronto, Toronto, ON M5S 3M2, Canada;
| | - Lindomar Pena
- Department of Virology, Aggeu Magalhaes Institute (IAM), Oswaldo Cruz Foundation (Fiocruz), 50670-420 Recife, Brazil;
- Correspondence: ; Tel.: +55-81-2123-7849
| |
Collapse
|
28
|
Field diagnosis and genotyping of chikungunya virus using a dried reverse transcription loop-mediated isothermal amplification (LAMP) assay and MinION sequencing. PLoS Negl Trop Dis 2019; 13:e0007480. [PMID: 31158221 PMCID: PMC6564047 DOI: 10.1371/journal.pntd.0007480] [Citation(s) in RCA: 21] [Impact Index Per Article: 4.2] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/06/2019] [Revised: 06/13/2019] [Accepted: 05/20/2019] [Indexed: 12/17/2022] Open
Abstract
Detection and sequencing of chikungunya virus (CHIKV) genome was performed using a combination of a modified reverse transcription loop-mediated isothermal amplification (RT-LAMP) method and a MinION sequencer. We developed the protocol for drying all the reagents for the RT-LAMP in a single reaction tube. Using this system, the CHIKV genome was effectively amplified under isothermal conditions, and used as a template for MinION sequencing with a laptop computer. Our in-house RT-LAMP method and MinION sequencing system were also validated with RNAs and serum samples from recent outbreaks of CHIKV patients in Brazil. The obtained sequence data confirmed the CHIKV outbreaks and identified the genotype. In summary, our established inexpensive on-site genome detection and sequencing system is applicable for both diagnosis of CHIKV infected patients and genotyping of the CHIKV virus in future outbreak in remote areas. Chikungunya virus has re-emerged as an important pathogen causing several outbreaks in the world. As the clinical symptoms of chikungunya is similar to other mosquito-borne febrile diseases, the definitive diagnosis of the disease is based on the detection of viral genome from the patient blood. Loop-mediated isothermal amplification (LAMP) is a method that rapidly amplify nucleic acids under isothermal condition. In the present work, a simple dried format LAMP test for chikungunya diagnosis was developed which can be directly amplified from human blood. Combining with the portable sequencer MinION sequencing system, a method to identify the viral genotype was also established. The developed on-site diagnosis and genotyping system is easy to perform, sensitive, and rapid. Therefore, it offers great promise as a routine simple tool for diagnosis and disease management of chikungunya.
Collapse
|
29
|
Dunbar S, Das S. Amplification chemistries in clinical virology. J Clin Virol 2019; 115:18-31. [PMID: 30953805 PMCID: PMC7106405 DOI: 10.1016/j.jcv.2019.03.015] [Citation(s) in RCA: 13] [Impact Index Per Article: 2.6] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/14/2018] [Revised: 02/19/2019] [Accepted: 03/25/2019] [Indexed: 01/04/2023]
Abstract
Molecular diagnostic methods have evolved and matured considerably over the last several decades and are constantly being evaluated and adopted by clinical laboratories for the identification of infectious pathogens. Advancement in other technologies such as fluorescence, electronics, instrumentation, automation, and sensors have made the overall diagnostic process more accurate, sensitive, and rapid. Nucleic acid based detection procedures, which rely on the fundamental principles of DNA replication have emerged as a popular and standard diagnostic method, and several commercial assays are currently available based on different nucleic acid amplification techniques. This review focuses on the major amplification chemistries that are used for developing commercial assays and discusses their application in the clinical virology laboratory.
Collapse
|
30
|
Khurshid Z, Zafar M, Khan E, Mali M, Latif M. Human saliva can be a diagnostic tool for Zika virus detection. J Infect Public Health 2019; 12:601-604. [PMID: 31129010 DOI: 10.1016/j.jiph.2019.05.004] [Citation(s) in RCA: 37] [Impact Index Per Article: 7.4] [Reference Citation Analysis] [Abstract] [Key Words] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/09/2018] [Revised: 09/21/2018] [Accepted: 05/05/2019] [Indexed: 02/08/2023] Open
Abstract
Zika virus (ZIKV), an Aedes mosquito-borne flavivirus, has captured public health attention worldwide. Initially, the virus was reported in Africa and Asia. However, the outbreak of ZIKV in Brazil and the United States of America demonstrated the global health risk. Symptoms of ZIKV infection vary from mild fever, rash, and joint pain to an apparent increase in microcephaly in infants and severe manifestations including Guillain-Barré syndrome in adults. Such consequences led to enormous health challenges, and consequently the World Health Organization declared a global health emergency. This review incorporates all aspects of ZIKV that could significantly impact human health, including epidemiology, clinical presentation, possible complications, cutting-edge therapeutic management of ZIKV infection, and latest developments in ZIKV diagnosis, particularly the value of human saliva as a diagnostic fluid.
Collapse
Affiliation(s)
- Zohaib Khurshid
- Department of Prosthodontics and Dental Implantology, College of Dentistry, King Faisal University, Al-Hofuf, Saudi Arabia.
| | - Muhammad Zafar
- Department of Dental Materials, College of Dentistry, Taibah University, Medina Munawwarah, Saudi Arabia; Department of Dental Materials, Islamic International Dental College, Riphah International University, Islamabad, Pakistan.
| | - Erum Khan
- Department of Oral Pathology, Liaquat University of Medical and Health Sciences, Jamshoro, Pakistan.
| | - Maria Mali
- Department of Orthodontics, College of Dentistry, Islamic International Dental College, Riphah International University, Islamabad, Pakistan.
| | - Muhammad Latif
- Centre for Genetics and Inherited Diseases (CGID), Taibah University, Medina Munawwarah, Saudi Arabia.
| |
Collapse
|
31
|
Moço ACR, Guedes PH, Flauzino JMR, da Silva HS, Vieira JG, Castro ACH, Gomes ÉVR, Tolentino FM, Soares MMCN, Madurro JM, Brito‐Madurro AG. Electrochemical Detection of Zika Virus in Biological Samples: A Step for Diagnosis Point‐of‐care. ELECTROANAL 2019. [DOI: 10.1002/elan.201900068] [Citation(s) in RCA: 19] [Impact Index Per Article: 3.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/13/2022]
Affiliation(s)
- Anna C. R. Moço
- Institute of BiotechnologyFederal University of Uberlândia Uberlândia BrazilTel. +55 34 32182203
| | - Pedro H. Guedes
- Institute of BiotechnologyFederal University of Uberlândia Uberlândia BrazilTel. +55 34 32182203
| | - José M. R. Flauzino
- Institute of BiotechnologyFederal University of Uberlândia Uberlândia BrazilTel. +55 34 32182203
| | | | - Jussara G. Vieira
- Institute of BiotechnologyFederal University of Uberlândia Uberlândia BrazilTel. +55 34 32182203
| | - Ana C. H. Castro
- Institute of BiotechnologyFederal University of Uberlândia Uberlândia BrazilTel. +55 34 32182203
| | - Érica V. R. Gomes
- Adolfo Lutz InstituteRegional Laboratory in São José do Rio Preto Brazil
| | | | | | - João M. Madurro
- Institute of ChemistryFederal University of Uberlândia Uberlândia Brazil
| | - Ana G. Brito‐Madurro
- Institute of BiotechnologyFederal University of Uberlândia Uberlândia BrazilTel. +55 34 32182203
| |
Collapse
|
32
|
Development and Validation of Reverse Transcription Loop-Mediated Isothermal Amplification (RT-LAMP) for Rapid Detection of ZIKV in Mosquito Samples from Brazil. Sci Rep 2019; 9:4494. [PMID: 30872672 PMCID: PMC6418238 DOI: 10.1038/s41598-019-40960-5] [Citation(s) in RCA: 45] [Impact Index Per Article: 9.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/06/2018] [Accepted: 12/10/2018] [Indexed: 12/29/2022] Open
Abstract
The rapid spread of Zika virus (ZIKV) represents a global public health problem, especially in areas that harbor several mosquito species responsible for virus transmission, such as Brazil. In these areas, improvement in mosquito control needs to be a top priority, but mosquito viral surveillance occurs inefficiently in ZIKV-endemic countries. Quantitative reverse transcription PCR (qRT-PCR) is the gold standard for molecular diagnostic of ZIKV in both human and mosquito samples. However, the technique presents high cost and limitations for Point-of-care (POC) diagnostics, which hampers its application for a large number of samples in entomological surveillance programs. Here, we developed and validated a one-step reverse transcription LAMP (RT-LAMP) platform for detection of ZIKV in mosquito samples. The RT-LAMP assay was highly specific for ZIKV and up to 10,000 times more sensitive than qRT-PCR. Assay validation was performed using 60 samples from Aedes aegypti and Culex quinquefasciatus mosquitoes collected in Pernambuco State, Brazil, which is at the epicenter of the Zika epidemic. The RT-LAMP had a sensitivity of 100%, specificity of 91.18%, and overall accuracy of 95.24%. Thus, our POC diagnostics is a powerful and inexpensive tool to monitor ZIKV in mosquito populations and will allow developing countries to establish better control strategies for this devastating pathogen.
Collapse
|
33
|
Jiang X, Loeb JC, Manzanas C, Lednicky JA, Fan ZH. Valve-Enabled Sample Preparation and RNA Amplification in a Coffee Mug for Zika Virus Detection. Angew Chem Int Ed Engl 2018; 57:17211-17214. [PMID: 30358036 DOI: 10.1002/anie.201809993] [Citation(s) in RCA: 28] [Impact Index Per Article: 4.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/30/2018] [Revised: 10/07/2018] [Indexed: 11/07/2022]
Abstract
The recent outbreaks of Zika virus (ZIKV) infection represent a public health challenge. Rapid, cost-effective, and reliable diagnostic tools for ZIKV detection at the point of care (POC) are highly desirable, especially for resource-limited nations. To address the need, we have developed an integrated device to achieve sample-to-answer ZIKV detection. The device features innovative ball-based valves enabling the storage and sequential delivery of reagents for virus lysis and a paper-based unit for RNA enrichment and purification. The paper unit is placed in a commercially available coffee mug that provides a constant temperature for reverse transcription loop-mediated isothermal amplification (RT-LAMP), followed by colorimetric detection by naked eye or a cellphone camera. Using the device, we demonstrated the reproducible detection of ZIKV in human urine and saliva samples.
Collapse
Affiliation(s)
- Xiao Jiang
- J. Crayton Pruitt Family Department of Biomedical Engineering, University of Florida, Gainesville, FL, 32611, USA
| | - Julia C Loeb
- Department of Environmental and Global Health, and Emerging Pathogens Institute, University of Florida, Gainesville, FL, 32611, USA
| | - Carlos Manzanas
- Department of Mechanical and Aerospace Engineering, University of Florida, P.O. Box 116250, Gainesville, FL, 32611, USA
| | - John A Lednicky
- Department of Environmental and Global Health, and Emerging Pathogens Institute, University of Florida, Gainesville, FL, 32611, USA
| | - Z Hugh Fan
- J. Crayton Pruitt Family Department of Biomedical Engineering, University of Florida, Gainesville, FL, 32611, USA.,Department of Mechanical and Aerospace Engineering, University of Florida, P.O. Box 116250, Gainesville, FL, 32611, USA
| |
Collapse
|
34
|
Jiang X, Loeb JC, Manzanas C, Lednicky JA, Fan ZH. Valve‐Enabled Sample Preparation and RNA Amplification in a Coffee Mug for Zika Virus Detection. Angew Chem Int Ed Engl 2018. [DOI: 10.1002/ange.201809993] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/13/2022]
Affiliation(s)
- Xiao Jiang
- J. Crayton Pruitt Family Department of Biomedical Engineering University of Florida Gainesville FL 32611 USA
| | - Julia C. Loeb
- Department of Environmental and Global Health, and Emerging Pathogens Institute University of Florida Gainesville FL 32611 USA
| | - Carlos Manzanas
- Department of Mechanical and Aerospace Engineering University of Florida P.O. Box 116250 Gainesville FL 32611 USA
| | - John A. Lednicky
- Department of Environmental and Global Health, and Emerging Pathogens Institute University of Florida Gainesville FL 32611 USA
| | - Z. Hugh Fan
- J. Crayton Pruitt Family Department of Biomedical Engineering University of Florida Gainesville FL 32611 USA
- Department of Mechanical and Aerospace Engineering University of Florida P.O. Box 116250 Gainesville FL 32611 USA
| |
Collapse
|
35
|
Parreira R. Laboratory Methods in Molecular Epidemiology: Viral Infections. Microbiol Spectr 2018; 6:10.1128/microbiolspec.ame-0003-2018. [PMID: 30387412 PMCID: PMC11633636 DOI: 10.1128/microbiolspec.ame-0003-2018] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/16/2018] [Indexed: 01/05/2023] Open
Abstract
Viruses, which are the most abundant biological entities on the planet, have been regarded as the "dark matter" of biology in the sense that despite their ubiquity and frequent presence in large numbers, their detection and analysis are not always straightforward. The majority of them are very small (falling under the limit of 0.5 μm), and collectively, they are extraordinarily diverse. In fact, the majority of the genetic diversity on the planet is found in the so-called virosphere, or the world of viruses. Furthermore, the most frequent viral agents of disease in humans display an RNA genome, and frequently evolve very fast, due to the fact that most of their polymerases are devoid of proofreading activity. Therefore, their detection, genetic characterization, and epidemiological surveillance are rather challenging. This review (part of the Curated Collection on Advances in Molecular Epidemiology of Infectious Diseases) describes many of the methods that, throughout the last few decades, have been used for viral detection and analysis. Despite the challenge of having to deal with high genetic diversity, the majority of these methods still depend on the amplification of viral genomic sequences, using sequence-specific or sequence-independent approaches, exploring thermal profiles or a single nucleic acid amplification temperature. Furthermore, viral populations, and especially those with RNA genomes, are not usually genetically uniform but encompass swarms of genetically related, though distinct, viral genomes known as viral quasispecies. Therefore, sequence analysis of viral amplicons needs to take this fact into consideration, as it constitutes a potential analytic problem. Possible technical approaches to deal with it are also described here. *This article is part of a curated collection.
Collapse
Affiliation(s)
- Ricardo Parreira
- Unidade de Microbiologia Médica/Global Health and Tropical Medicine (GHTM) Research Centre, Instituto de Higiene e Medicina Tropical (IHMT), Universidade Nova de Lisboa (UNL), 1349-008 Lisboa, Portugal
| |
Collapse
|
36
|
Castro T, Sabalza M, Barber C, Abrams W, Da Costa AC, De Pádua Milagres FA, Braz-Silva PH, Malamud D, Gallottini M. Rapid diagnosis of Zika virus through saliva and urine by Loop-mediated isothermal amplification (LAMP). J Oral Microbiol 2018; 10:1510712. [PMID: 30202506 PMCID: PMC6127837 DOI: 10.1080/20002297.2018.1510712] [Citation(s) in RCA: 17] [Impact Index Per Article: 2.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/02/2018] [Revised: 07/30/2018] [Accepted: 08/02/2018] [Indexed: 01/09/2023] Open
Abstract
Background: Zika virus (ZIKV) is a single-stranded RNA virus and member of the Flaviviridae family. Recent studies have reported that saliva can be an important alternative to detect ZIKV. Saliva requires less processing than blood greatly simplifying the assay. Loop-mediated Isothermal Amplification (LAMP) is a rapid assay that detects nucleic acids, including ZIKV RNA. Aim: The aim of this study was to evaluate the efficacy of saliva and urine to diagnose ZIKV infection in subjects during the acute phase, through ZIKV RNA detection by LAMP. Method: A total of 131 samples (68 saliva and 63 urine samples) from 69 subjects in the acute phase of ZIKV infection, and confirmed positive for ZIKV by blood analysis through real time-PCR, were collected and analyzed by Reverse Transcriptase Loop-mediated Isothermal Amplification (RT-LAMP). Results: From the 68 saliva samples, 45 (66.2%) were positive for ZIKV with an average time to positivity (Tp) of 13.5 min, and from the 63 urine samples, 25 (39.7%) were positive with the average Tp of 15.8 min. Saliva detected more samples (p = 0.0042) and had faster Tp (p = 0.0176) as compared with urine. Conclusion: Saliva proved to be a feasible alternative to diagnose ZIKV infection during the acute phase by LAMP.
Collapse
Affiliation(s)
- Talita Castro
- Stomatology Department, School of Dentistry, University of São Paulo, São Paulo, SP, Brazil
| | - Maite Sabalza
- Department of Basic Science and Craniofacial Biology, College of Dentistry, New York University, New York, NY, USA
| | - Cheryl Barber
- Department of Basic Science and Craniofacial Biology, College of Dentistry, New York University, New York, NY, USA
| | - William Abrams
- Department of Basic Science and Craniofacial Biology, College of Dentistry, New York University, New York, NY, USA
| | - Antonio Charlys Da Costa
- Laboratory of Medical Research, Institute of Tropical Medicine, University of São Paulo, São Paulo, SP, Brazil
| | - Flavio Augusto De Pádua Milagres
- Epidemiological Surveillance and Infectious Diseases, Secretary of Health of Tocantins and Federal University of Tocantins, Palmas, TO, Brazil
| | - Paulo Henrique Braz-Silva
- Stomatology Department, School of Dentistry, University of São Paulo, São Paulo, SP, Brazil.,Laboratory of Medical Research, Institute of Tropical Medicine, University of São Paulo, São Paulo, SP, Brazil
| | - Daniel Malamud
- Department of Basic Science and Craniofacial Biology, College of Dentistry, New York University, New York, NY, USA
| | - Marina Gallottini
- Stomatology Department, School of Dentistry, University of São Paulo, São Paulo, SP, Brazil
| |
Collapse
|