1
|
LeChevallier MW, Prosser T, Stevens M. Opportunistic Pathogens in Drinking Water Distribution Systems-A Review. Microorganisms 2024; 12:916. [PMID: 38792751 PMCID: PMC11124194 DOI: 10.3390/microorganisms12050916] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/01/2024] [Revised: 04/24/2024] [Accepted: 04/25/2024] [Indexed: 05/26/2024] Open
Abstract
In contrast to "frank" pathogens, like Salmonella entrocolitica, Shigella dysenteriae, and Vibrio cholerae, that always have a probability of disease, "opportunistic" pathogens are organisms that cause an infectious disease in a host with a weakened immune system and rarely in a healthy host. Historically, drinking water treatment has focused on control of frank pathogens, particularly those from human or animal sources (like Giardia lamblia, Cryptosporidium parvum, or Hepatitis A virus), but in recent years outbreaks from drinking water have increasingly been due to opportunistic pathogens. Characteristics of opportunistic pathogens that make them problematic for water treatment include: (1) they are normally present in aquatic environments, (2) they grow in biofilms that protect the bacteria from disinfectants, and (3) under appropriate conditions in drinking water systems (e.g., warm water, stagnation, low disinfectant levels, etc.), these bacteria can amplify to levels that can pose a public health risk. The three most common opportunistic pathogens in drinking water systems are Legionella pneumophila, Mycobacterium avium, and Pseudomonas aeruginosa. This report focuses on these organisms to provide information on their public health risk, occurrence in drinking water systems, susceptibility to various disinfectants, and other operational practices (like flushing and cleaning of pipes and storage tanks). In addition, information is provided on a group of nine other opportunistic pathogens that are less commonly found in drinking water systems, including Aeromonas hydrophila, Klebsiella pneumoniae, Serratia marcescens, Burkholderia pseudomallei, Acinetobacter baumannii, Stenotrophomonas maltophilia, Arcobacter butzleri, and several free-living amoebae including Naegleria fowleri and species of Acanthamoeba. The public health risk for these microbes in drinking water is still unclear, but in most cases, efforts to manage Legionella, mycobacteria, and Pseudomonas risks will also be effective for these other opportunistic pathogens. The approach to managing opportunistic pathogens in drinking water supplies focuses on controlling the growth of these organisms. Many of these microbes are normal inhabitants in biofilms in water, so the attention is less on eliminating these organisms from entering the system and more on managing their occurrence and concentrations in the pipe network. With anticipated warming trends associated with climate change, the factors that drive the growth of opportunistic pathogens in drinking water systems will likely increase. It is important, therefore, to evaluate treatment barriers and management activities for control of opportunistic pathogen risks. Controls for primary treatment, particularly for turbidity management and disinfection, should be reviewed to ensure adequacy for opportunistic pathogen control. However, the major focus for the utility's opportunistic pathogen risk reduction plan is the management of biological activity and biofilms in the distribution system. Factors that influence the growth of microbes (primarily in biofilms) in the distribution system include, temperature, disinfectant type and concentration, nutrient levels (measured as AOC or BDOC), stagnation, flushing of pipes and cleaning of storage tank sediments, and corrosion control. Pressure management and distribution system integrity are also important to the microbial quality of water but are related more to the intrusion of contaminants into the distribution system rather than directly related to microbial growth. Summarizing the identified risk from drinking water, the availability and quality of disinfection data for treatment, and guidelines or standards for control showed that adequate information is best available for management of L. pneumophila. For L. pneumophila, the risk for this organism has been clearly established from drinking water, cases have increased worldwide, and it is one of the most identified causes of drinking water outbreaks. Water management best practices (e.g., maintenance of a disinfectant residual throughout the distribution system, flushing and cleaning of sediments in pipelines and storage tanks, among others) have been shown to be effective for control of L. pneumophila in water supplies. In addition, there are well documented management guidelines available for the control of the organism in drinking water distribution systems. By comparison, management of risks for Mycobacteria from water are less clear than for L. pneumophila. Treatment of M. avium is difficult due to its resistance to disinfection, the tendency to form clumps, and attachment to surfaces in biofilms. Additionally, there are no guidelines for management of M. avium in drinking water, and one risk assessment study suggested a low risk of infection. The role of tap water in the transmission of the other opportunistic pathogens is less clear and, in many cases, actions to manage L. pneumophila (e.g., maintenance of a disinfectant residual, flushing, cleaning of storage tanks, etc.) will also be beneficial in helping to manage these organisms as well.
Collapse
Affiliation(s)
| | - Toby Prosser
- Melbourne Water, Melbourne, VIC 3001, Australia; (T.P.); (M.S.)
| | - Melita Stevens
- Melbourne Water, Melbourne, VIC 3001, Australia; (T.P.); (M.S.)
| |
Collapse
|
2
|
Liu S, Xia S, Zhang X, Cai X, Yang J, Hu Y, Zhou S, Wang H. Microbial communities exhibit distinct diversities and assembly mechanisms in rainwater and tap-water storage systems. WATER RESEARCH 2024; 253:121305. [PMID: 38367380 DOI: 10.1016/j.watres.2024.121305] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 12/18/2023] [Revised: 02/08/2024] [Accepted: 02/10/2024] [Indexed: 02/19/2024]
Abstract
Roof-harvested rainwater stored for potable and nonpotable usages represent a clean and sustainable water supply resource. However, the microbial dynamics and mechanisms of community assembly in long-termed operated rainwater storage systems remain elusive. In this study, characteristics of microbial communities in different habitats were systematically compared within rainwater and tap-water simulated storage systems (SWSSs) constructed with different tank materials (PVC, stainless steel and cement). Distinct microbial communities were observed between rainwater and tap-water SWSSs for both water and biofilm samples (ANOSIM, p < 0.05), with lower diversity indexes noted in rainwater samples. Notably, a divergent potential pathogen profile was observed between rainwater and tap-water SWSSs, with higher relative abundances of potential pathogens noted in rainwater SWSSs. Moreover, tank materials had a notable impact on microbial communities in rainwater SWSSs (ANOSIM, p < 0.05), rather than tap-water SWSSs, illustrating the distinct interplay between water chemistry and engineering factors in shaping the SWSS microbiomes. Deterministic processes contributed predominantly to the microbial community assembly in cement rainwater SWSSs and all tap-water SWSSs, which might be ascribed to the high pH levels in cement rainwater SWSSs and low-nutrient levels in all tap-water SWSSs, respectively. However, microbial communities in the PVC and stainless-steel rainwater SWSSs were mainly driven by stochastic processes. Overall, the results provided insights to the distinct microbial assembly mechanisms and potential health risks in stored roof-harvested rainwater, highlighting the importance of developing tailored microbial management strategies for the storage and utilization of rainwater.
Collapse
Affiliation(s)
- Sihang Liu
- State Key Laboratory of Pollution Control and Resource Reuse, College of Environmental Science and Engineering, Tongji University, Shanghai 200092, China; Shanghai Institute of Pollution Control and Ecological Security, Shanghai 200092, China
| | - Siqing Xia
- State Key Laboratory of Pollution Control and Resource Reuse, College of Environmental Science and Engineering, Tongji University, Shanghai 200092, China; Shanghai Institute of Pollution Control and Ecological Security, Shanghai 200092, China.
| | - Xiaodong Zhang
- State Key Laboratory of Pollution Control and Resource Reuse, College of Environmental Science and Engineering, Tongji University, Shanghai 200092, China
| | - Xucheng Cai
- State Key Laboratory of Pollution Control and Resource Reuse, College of Environmental Science and Engineering, Tongji University, Shanghai 200092, China
| | - Jinhao Yang
- State Key Laboratory of Pollution Control and Resource Reuse, College of Environmental Science and Engineering, Tongji University, Shanghai 200092, China
| | - Yuxing Hu
- State Key Laboratory of Pollution Control and Resource Reuse, College of Environmental Science and Engineering, Tongji University, Shanghai 200092, China
| | - Shuang Zhou
- School of Medicine, Tongji University, Shanghai 200092, China
| | - Hong Wang
- State Key Laboratory of Pollution Control and Resource Reuse, College of Environmental Science and Engineering, Tongji University, Shanghai 200092, China; Shanghai Institute of Pollution Control and Ecological Security, Shanghai 200092, China.
| |
Collapse
|
3
|
Nisar MA, Ros KE, Brown MH, Bentham R, Best G, Xi J, Hinds J, Whiley H. Stagnation arising through intermittent usage is associated with increased viable but non culturable Legionella and amoeba hosts in a hospital water system. Front Cell Infect Microbiol 2023; 13:1190631. [PMID: 37351181 PMCID: PMC10282743 DOI: 10.3389/fcimb.2023.1190631] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/21/2023] [Accepted: 05/18/2023] [Indexed: 06/24/2023] Open
Abstract
Hospital water systems are a significant source of Legionella, resulting in the potentially fatal Legionnaires' disease. One of the biggest challenges for Legionella management within these systems is that under unfavorable conditions Legionella transforms itself into a viable but non culturable (VBNC) state that cannot be detected using the standard methods. This study used a novel method (flow cytometry-cell sorting and qPCR [VFC+qPCR] assay) concurrently with the standard detection methods to examine the effect of temporary water stagnation, on Legionella spp. and microbial communities present in a hospital water system. Water samples were also analyzed for amoebae using culture and Vermamoeba vermiformis and Acanthamoeba specific qPCR. The water temperature, number and duration of water flow events for the hand basins and showers sampled was measured using the Enware Smart Flow® monitoring system. qPCR analysis demonstrated that 21.8% samples were positive for Legionella spp., 21% for L. pneumophila, 40.9% for V. vermiformis and 4.2% for Acanthamoeba. All samples that were Legionella spp. positive using qPCR (22%) were also positive for VBNC Legionella spp.; however, only 2.5% of samples were positive for culturable Legionella spp. 18.1% of the samples were positive for free-living amoebae (FLA) using culture. All samples positive for Legionella spp. were also positive for FLA. Samples with a high heterotrophic plate count (HPC ≥ 5 × 103 CFU/L) were also significantly associated with high concentrations of Legionella spp. DNA, VBNC Legionella spp./L. pneumophila (p < 0.01) and V. vermiformis (p < 0.05). Temporary water stagnation arising through intermittent usage (< 2 hours of usage per month) significantly (p < 0.01) increased the amount of Legionella spp. DNA, VBNC Legionella spp./L. pneumophila, and V. vermiformis; however, it did not significantly impact the HPC load. In contrast to stagnation, no relationship was observed between the microbes and water temperature. In conclusion, Legionella spp. (DNA and VBNC) was associated with V. vermiformis, heterotrophic bacteria, and stagnation occurring through intermittent usage. This is the first study to monitor VBNC Legionella spp. within a hospital water system. The high percentage of false negative Legionella spp. results provided by the culture method supports the use of either qPCR or VFC+qPCR to monitor Legionella spp. contamination within hospital water systems.
Collapse
Affiliation(s)
- Muhammad Atif Nisar
- College of Science and Engineering, Flinders University, Bedford Park, SA, Australia
| | - Kirstin E. Ros
- College of Science and Engineering, Flinders University, Bedford Park, SA, Australia
| | - Melissa H. Brown
- College of Science and Engineering, Flinders University, Bedford Park, SA, Australia
- Australian Research Council Training Centre for Biofilm Research and Innovation, Flinders University, Bedford Park, SA, Australia
| | - Richard Bentham
- College of Science and Engineering, Flinders University, Bedford Park, SA, Australia
| | - Giles Best
- College of Medicine and Public Health, Flinders University, Bedford Park, SA, Australia
- Flow Cytometry Facility, Flinders University, Bedford Park, SA, Australia
| | - James Xi
- Enware Australia Pty Ltd., Caringbah, NSW, Australia
| | - Jason Hinds
- Enware Australia Pty Ltd., Caringbah, NSW, Australia
| | - Harriet Whiley
- College of Science and Engineering, Flinders University, Bedford Park, SA, Australia
- Australian Research Council Training Centre for Biofilm Research and Innovation, Flinders University, Bedford Park, SA, Australia
| |
Collapse
|
4
|
The Presence of Opportunistic Premise Plumbing Pathogens in Residential Buildings: A Literature Review. WATER 2022. [DOI: 10.3390/w14071129] [Citation(s) in RCA: 10] [Impact Index Per Article: 5.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 02/06/2023]
Abstract
Opportunistic premise plumbing pathogens (OPPP) are microorganisms that are native to the plumbing environment and that present an emerging infectious disease problem. They share characteristics, such as disinfectant resistance, thermal tolerance, and biofilm formation. The colonisation of domestic water systems presents an elevated health risk for immune-compromised individuals who receive healthcare at home. The literature that has identified the previously described OPPPs (Aeromonas spp., Acinetobacter spp., Helicobacter spp., Legionella spp., Methylobacterium spp., Mycobacteria spp., Pseudomonas spp., and Stenotrophomonas spp.) in residential drinking water systems were systematically reviewed. By applying the Preferred reporting items for systematic reviews and meta-analyses guidelines, 214 studies were identified from the Scopus and Web of Science databases, which included 30 clinical case investigations. Tap components and showerheads were the most frequently identified sources of OPPPs. Sixty-four of these studies detected additional clinically relevant pathogens that are not classified as OPPPs in these reservoirs. There was considerable variation in the detection methods, which included traditional culturing and molecular approaches. These identified studies demonstrate that the current drinking water treatment methods are ineffective against many waterborne pathogens. It is critical that, as at-home healthcare services continue to be promoted, we understand the emergent risks that are posed by OPPPs in residential drinking water. Future research is needed in order to provide consistent data on the prevalence of OPPPs in residential water, and on the incidence of waterborne homecare-associated infections. This will enable the identification of the contributing risk factors, and the development of effective controls.
Collapse
|
5
|
Salehi M. Global water shortage and potable water safety; Today's concern and tomorrow's crisis. ENVIRONMENT INTERNATIONAL 2022; 158:106936. [PMID: 34655888 DOI: 10.1016/j.envint.2021.106936] [Citation(s) in RCA: 70] [Impact Index Per Article: 35.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 08/24/2021] [Revised: 10/10/2021] [Accepted: 10/11/2021] [Indexed: 05/28/2023]
Abstract
Climate change, severe droughts, population growth, demand increase, and poor management during the recent decades have further stressed the scarce freshwater resources worldwide and resulted in severe water shortages in many regions. The water utilities address the water shortage by providing alternative source of water, augment the supplied water, supply intermittently, and even bulk water delivery under severe water shortage conditions. On the other hand, many households store water in building storage tanks to cope with insufficient delivery of potable water due to frequent interruptions. All these practices could pose crucial risks to the chemical and microbiological quality of the water. However, consistent monitoring and implementation of mitigation strategies could lower the potential risks associated with these practices. It is critical to identify the potential hazards resulting from the alternative water supplies and distribution practices to develop temporary and long-term monitoring and mitigation plans and reduce the microbial and chemical contamination of potable water delivered to the consumers. This paper provides a holistic review of the significant hazards associated with the practices employed by the water utilities and water consumers to alleviate the potable water shortage and discusses the required monitoring and mitigation practices.
Collapse
Affiliation(s)
- Maryam Salehi
- Department of Civil Engineering, The University of Memphis, 3815 Central Avenue, 108C Engineering Science Bldg, Memphis, TN 38152, United States.
| |
Collapse
|
6
|
De Giglio O, Napoli C, Diella G, Fasano F, Lopuzzo M, Apollonio F, D'Ambrosio M, Campanale C, Triggiano F, Caggiano G, Montagna MT. Integrated approach for legionellosis risk analysis in touristic-recreational facilities. ENVIRONMENTAL RESEARCH 2021; 202:111649. [PMID: 34252427 DOI: 10.1016/j.envres.2021.111649] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 05/13/2021] [Revised: 06/30/2021] [Accepted: 07/02/2021] [Indexed: 06/13/2023]
Abstract
Legionellosis is a severe pneumonia caused by the inhalation of aerosols containing Legionella, Gram-negative bacteria present in the water systems of touristic-recreational facilities. The purpose of this study was to develop a scoring tool to predict the risk of both environmental contamination and Legionnaires' disease cases in such facilities in the Apulia region of southern Italy. We analyzed 47 structural and management parameters/risk factors related to the buildings, water systems, and air conditioning at the facilities. A Poisson regression model was used to compute an overall risk score for each facility with respect to three outcomes: water samples positive for Legionella (risk score range: 7-54), water samples positive for Legionella with an average load exceeding 1000 colony-forming units per liter (CFU/L) (risk score range: 22-179,871), and clinical cases of Legionnaire's disease (risk score range: 6-31). The cut-off values for three outcomes were determined by receiver operating characteristic curves (first outcome, samples positive for Legionella in a touristic-recreational facility: 19; second outcome, samples positive for Legionella in a touristic-recreational facility with an average load exceeding 1000 CFU/L: 2062; third outcome, clinical cases of Legionnaire's disease in a touristic-recreational facility: 22). Above these values, there was a significant probability of observing the outcome. We constructed this predictive model using 70% of a large dataset (18 years of clinical and environmental surveillance) and tested the model on the remaining 30% of the dataset to demonstrate its reliability. Our model enables the assessment of risk for a touristic facility and the creation of a conceptual framework to link the risk analysis with prevention measures.
Collapse
Affiliation(s)
- Osvalda De Giglio
- Regional Reference Laboratory of Clinical and Environmental Surveillance of Legionellosis, Department of Biomedical Science and Human Oncology, University of Bari Aldo Moro, Piazza G. Cesare 11, 70124, Bari, Italy.
| | - Christian Napoli
- Department of Medical Surgical Sciences and Translational Medicine, "Sapienza" University of Rome, Via di Grottarossa 1035/1039, 00189, Rome, Italy.
| | - Giusy Diella
- Regional Reference Laboratory of Clinical and Environmental Surveillance of Legionellosis, Department of Biomedical Science and Human Oncology, University of Bari Aldo Moro, Piazza G. Cesare 11, 70124, Bari, Italy.
| | - Fabrizio Fasano
- Regional Reference Laboratory of Clinical and Environmental Surveillance of Legionellosis, Department of Biomedical Science and Human Oncology, University of Bari Aldo Moro, Piazza G. Cesare 11, 70124, Bari, Italy.
| | - Marco Lopuzzo
- Regional Reference Laboratory of Clinical and Environmental Surveillance of Legionellosis, Department of Biomedical Science and Human Oncology, University of Bari Aldo Moro, Piazza G. Cesare 11, 70124, Bari, Italy.
| | - Francesca Apollonio
- Regional Reference Laboratory of Clinical and Environmental Surveillance of Legionellosis, Department of Biomedical Science and Human Oncology, University of Bari Aldo Moro, Piazza G. Cesare 11, 70124, Bari, Italy.
| | - Marilena D'Ambrosio
- Regional Reference Laboratory of Clinical and Environmental Surveillance of Legionellosis, Department of Biomedical Science and Human Oncology, University of Bari Aldo Moro, Piazza G. Cesare 11, 70124, Bari, Italy.
| | - Carmen Campanale
- Regional Reference Laboratory of Clinical and Environmental Surveillance of Legionellosis, Department of Biomedical Science and Human Oncology, University of Bari Aldo Moro, Piazza G. Cesare 11, 70124, Bari, Italy.
| | - Francesco Triggiano
- Regional Reference Laboratory of Clinical and Environmental Surveillance of Legionellosis, Department of Biomedical Science and Human Oncology, University of Bari Aldo Moro, Piazza G. Cesare 11, 70124, Bari, Italy.
| | - Giuseppina Caggiano
- Regional Reference Laboratory of Clinical and Environmental Surveillance of Legionellosis, Department of Biomedical Science and Human Oncology, University of Bari Aldo Moro, Piazza G. Cesare 11, 70124, Bari, Italy.
| | - Maria Teresa Montagna
- Regional Reference Laboratory of Clinical and Environmental Surveillance of Legionellosis, Department of Biomedical Science and Human Oncology, University of Bari Aldo Moro, Piazza G. Cesare 11, 70124, Bari, Italy.
| |
Collapse
|
7
|
Bolelli L, Ferri EN, Sangiorgi S, Novelli G, Girotti S. The pursuit of good microbiological conditions in domestic softeners: a new improvement. JOURNAL OF WATER AND HEALTH 2020; 18:200-206. [PMID: 32300092 DOI: 10.2166/wh.2020.136] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/11/2023]
Abstract
Effective resin disinfection is mandatory to ensure the microbiological quality of water treated by domestic softeners. The wet and sometimes warm environment inside the softener is ideal for bacteria growth. Our research was focused on the evaluation of the microbial quality of water from softeners sanitized by chlorine solutions or by electrolytic systems. We employed the heterotrophic plate count and specific tests to monitor the presence of opportunistic and pathogenic bacteria (Pseudomonas aeruginosa, Escherichia coli, enterococci, and coliforms). Completely new devices were equipped with a commercially available electrolytic system or with a newly patented one or sanitized by automatic or manual addition of chlorine solutions. In all cases, the contamination was reduced, not completely avoided. In particular, the patented electrolytic system significantly reduced bacterial proliferation in strongly contaminated devices. Our data confirm the difficulties encountered to solve the problem of microbiological quality of softened water and offer encouraging information on new possible solutions.
Collapse
Affiliation(s)
- L Bolelli
- University of Bologna, Via S. Donato 15, 40127 Bologna, Italy E-mail:
| | - Elida Nora Ferri
- University of Bologna, Via S. Donato 15, 40127 Bologna, Italy E-mail:
| | - Stefano Sangiorgi
- University of Bologna, Via S. Donato 15, 40127 Bologna, Italy E-mail:
| | - Giuseppe Novelli
- Culligan Italiana SpA, Via Gandolfi 6, 40057 Cadriano di Granarolo Emilia, Bologna, Italy
| | - Stefano Girotti
- University of Bologna, Via S. Donato 15, 40127 Bologna, Italy E-mail:
| |
Collapse
|
8
|
LeChevallier MW. Occurrence of culturable
Legionella pneumophila
in drinking water distribution systems. ACTA ACUST UNITED AC 2019. [DOI: 10.1002/aws2.1139] [Citation(s) in RCA: 16] [Impact Index Per Article: 3.2] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/09/2022]
|