1
|
Yang Y, Chen C, Chen Z, Zeng L, Xue F, Zhou J. Redistribution of Epithelium and Stroma and Their Relationship With Corneal Curvature After 1-Month Cessation of Overnight Orthokeratology. Eye Contact Lens 2024; 50:249-254. [PMID: 38687606 DOI: 10.1097/icl.0000000000001085] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Accepted: 01/31/2024] [Indexed: 05/02/2024]
Abstract
OBJECTIVES To investigate the changes in the thickness of epithelium and stroma and their relationship with corneal curvature following the cessation of overnight orthokeratology for a period of 1 month. METHODS This prospective study consecutively included 20 juveniles (20 right eyes) who had undergone overnight orthokeratology for a minimum of one year and were willing to discontinue the treatment. The study measured and compared epithelial and corneal curvature using optical coherence tomography and Medmont topographer at the first day of cessation and 1 month after cessation. In addition, changes in uncorrected visual acuity and refractive error before and after the cessation of the treatment were analyzed. RESULTS The study found a significant increase in the thickness of the epithelium in the central 2-mm area after the cessation of the treatment (t = -4.807, P <0.001). Moreover, the stroma in the paracentral area (2-5 mm) and peripheral area (5-6 mm) showed a general thinning trend ( P =0.016, P =0.016). Regarding the correlation analysis, the change in central epithelial thickness (ΔCET) was significantly correlated with the change in paracentral corneal curvature (ΔPCCC) (r=0.610, P =0.007) and the change in peripheral corneal curvature (ΔPCC) (r=0.597, P =0.009). Similarly, the change in central stromal thickness (ΔCST) was significantly correlated with the change in central corneal curvature (ΔCCC) (r=0.500, P =0.035), ΔPCCC (r=0.700, P =0.001), and ΔPCC (r=0.635, P =0.005). CONCLUSIONS The study found that the corneal remodeling induced by orthokeratology was reversible after the cessation of the treatment. Specifically, changes in the epithelium were found to be more prominent in the central area, while changes in the stroma were more pronounced in the paracentral and peripheral areas. In addition, the study established a significant correlation between central corneal remodeling and changes in curvature.
Collapse
Affiliation(s)
- Ying Yang
- Department of Ophthalmology (Y.Y.), Jiangsu Province Hospital of Chinese Medicine, Affiliated Hospital of Nanjing University of Chinese Medicine, Nanjing, Jiangsu Province, People's Republic of China; and Department of Ophthalmology (C.C., Z.C., L.Z., F.X., J.Z.), Eye & ENT Hospital, Fudan University, NHC Key Laboratory of Myopia (Fudan University), Key Laboratory of Myopia, Chinese Academy of Medical Sciences, Shanghai Research Centre of Ophthalmology and Optometry, Shanghai, People's Republic of China
| | | | | | | | | | | |
Collapse
|
2
|
Martínez-Plaza E, López-de la Rosa A, Molina-Martín A, Piñero DP. Orthokeratology effect on the corneoscleral profile: Beyond the bull's eye. Ophthalmic Physiol Opt 2024; 44:757-768. [PMID: 38240175 DOI: 10.1111/opo.13279] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/05/2023] [Revised: 01/08/2024] [Accepted: 01/09/2024] [Indexed: 05/01/2024]
Abstract
PURPOSE To assess the impact of 3 months of orthokeratology (ortho-k) contact lenses (CLs) for myopia correction on the corneoscleral profile, as changes in scleral geometry could serve as indirect evidence of alteration in the corneal biomechanical properties. METHODS Twenty subjects (40 eyes) were recruited to wear ortho-k lenses overnight; however, after discontinuation (two CL fractures, one under-correction and two non-serious adverse events), 16 subjects (31 eyes) finished a 3-month follow-up. Corneoscleral topographies were acquired using the Eye Surface Profiler (ESP) system before and after 3 months of lens wear. Steep (SimKs) and flat (SimKf) simulated keratometry and scleral sagittal height measurements for 13-, 14- and 15-mm chord lengths were automatically calculated by the ESP software. Additionally, sagittal height and slope were calculated in polar format from 21 radii (0-10 mm from the corneal apex) at 12 angles (0-330°). Linear mixed models were fitted to determine the differences between visits. RESULTS SimKs and SimKf were increased significantly (p ≤ 0.02). The sagittal height in polar format increased significantly (p = 0.046) at a radius of 2.5 mm for 150°, 180°, 210° and 240° orientations and at a radius of 3.0 mm for 210°. Additionally, the slope in polar format significantly decreased (p ≤ 0.04) at radii ranges of 0.0-0.5, 0.5-1.0 and 1.0-1.5 mm for multiple angles and at a radii range of 5.0-5.5 mm for 90°. It also increased significantly (p ≤ 0.045) at a radii range of 1.5-2.0 mm for 30° and at radii ranges of 2.0-2.5, 2.5-3.0 and 3.0-3.5 mm for multiple angles. No significant changes were found for any parameter measured from the scleral area. CONCLUSIONS Three months of overnight ortho-k lens wear changed the central and mid-peripheral corneal geometry as expected, maintaining the peripheral cornea and the surrounding sclera stability.
Collapse
Affiliation(s)
- Elena Martínez-Plaza
- Group of Optics and Visual Perception, Department of Optics, Pharmacology and Anatomy, University of Alicante, Alicante, Spain
- University of Valladolid, Valladolid, Spain
| | - Alberto López-de la Rosa
- Department of Theoretical Physics, Atomic and Optics, University of Valladolid, Valladolid, Spain
- Instituto de Oftalmobiología Aplicada (IOBA), University of Valladolid, Valladolid, Spain
| | - Ainhoa Molina-Martín
- Group of Optics and Visual Perception, Department of Optics, Pharmacology and Anatomy, University of Alicante, Alicante, Spain
| | - David P Piñero
- Group of Optics and Visual Perception, Department of Optics, Pharmacology and Anatomy, University of Alicante, Alicante, Spain
- Department of Ophthalmology, Vithas Medimar International Hospital, Alicante, Spain
| |
Collapse
|
3
|
Pattan HF, Liu X, Tankam P. In vivo assessment of human corneal epithelial cells in orthokeratology lens wearers: A pilot study. Optom Vis Sci 2024; 101:263-271. [PMID: 38683973 DOI: 10.1097/opx.0000000000002130] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 05/02/2024] Open
Abstract
SIGNIFICANCE Central corneal epithelial thinning associated with midperipheral epithelial thickening has been reported as the main factor contributing to the effectiveness of orthokeratology (ortho-k) in myopia control. Yet, the cellular mechanism governing the regional change in refractive power remains elusive. PURPOSE This study aimed to evaluate the correlation between the regional change in corneal epithelial thickness and cell density in ortho-k wearers. METHODS A new human prototype of a polarization-dependent optical coherence microscope was developed to enable noncontact and noninvasive in vivo imaging of corneal epithelial cells in ortho-k wearers with and without their ortho-k lens. The epithelial thickness and cell density were evaluated at the central and midperipheral corneal locations in four ortho-k wearers and four spectacle wearers serving as controls. RESULTS Polarization-dependent optical coherence microscope achieved in vivo volumetric imaging of all epithelial cell types in ortho-k wearers with and without their lens over a field of view of 0.5 × 0.5 mm 2 with an isotropic resolution of ~2.2 mm. The central epithelial thinning and midperipheral epithelial thickening were consistent across all ortho-k wearers. However, the inconsistency in their regional epithelial cell density highlighted a great variability in individual response to ortho-k treatment. There was no strong correlation between epithelial thickness and cell density, especially at the midperipheral cornea, in ortho-k participants. CONCLUSIONS This study constitutes our first step toward uncovering the cellular mechanism underlying the effectiveness of ortho-k in myopia control. Future studies will focus on the longitudinal evaluation of epithelial cells before and during ortho-k treatment to identify factors governing individual response to ortho-k treatment and ultimately inform the dynamics of epithelial cells taking place during the ortho-k treatment.
Collapse
Affiliation(s)
- Hadiya F Pattan
- School of Optometry, Indiana University, Bloomington, Indiana
| | - Xiao Liu
- School of Optometry, Indiana University, Bloomington, Indiana
| | | |
Collapse
|
4
|
Abtahi MA, Beheshtnejad AH, Latifi G, Akbari-Kamrani M, Ghafarian S, Masoomi A, Sonbolastan SA, Jahanbani-Ardakani H, Atighechian M, Banan L, Nouri H, Abtahi SH. Corneal Epithelial Thickness Mapping: A Major Review. J Ophthalmol 2024; 2024:6674747. [PMID: 38205099 PMCID: PMC10776199 DOI: 10.1155/2024/6674747] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/20/2022] [Revised: 06/27/2023] [Accepted: 12/21/2023] [Indexed: 01/12/2024] Open
Abstract
The corneal epithelium (CE) is the outermost layer of the cornea with constant turnover, relative stability, remarkable plasticity, and compensatory properties to mask alterations in the underlying stroma. The advent of quantitative imaging modalities capable of producing epithelial thickness mapping (ETM) has made it possible to characterize better the different patterns of epithelial remodeling. In this comprehensive synthesis, we reviewed all available data on ETM with different methods, including very high-frequency ultrasound (VHF-US) and spectral-domain optical coherence tomography (SD-OCT) in normal individuals, corneal or systemic diseases, and corneal surgical scenarios. We excluded OCT studies that manually measured the corneal epithelial thickness (CET) (e.g., by digital calipers) or the CE (e.g., by confocal scanning or handheld pachymeters). A comparison of different CET measuring technologies and devices capable of producing thickness maps is provided. Normative data on CET and the possible effects of gender, aging, diurnal changes, refraction, and intraocular pressure are discussed. We also reviewed ETM data in several corneal disorders, including keratoconus, corneal dystrophies, recurrent epithelial erosion, herpes keratitis, keratoplasty, bullous keratopathy, carcinoma in situ, pterygium, and limbal stem cell deficiency. The available data on the potential role of ETM in indicating refractive surgeries, planning the procedure, and assessing postoperative changes are reviewed. Alterations in ETM in systemic and ocular conditions such as eyelid abnormalities and dry eye disease and the effects of contact lenses, topical medications, and cataract surgery on the ETM profile are discussed.
Collapse
Affiliation(s)
| | | | - Golshan Latifi
- Farabi Eye Hospital, Tehran University of Medical Sciences, Tehran, Iran
| | | | - Sadegh Ghafarian
- Farabi Eye Hospital, Tehran University of Medical Sciences, Tehran, Iran
| | - Ahmad Masoomi
- Farabi Eye Hospital, Tehran University of Medical Sciences, Tehran, Iran
| | | | | | | | - Laleh Banan
- Sunshine Coast University Hospital, Brisbane, Queensland, Australia
| | - Hosein Nouri
- Ophthalmic Research Center, Research Institute for Ophthalmology and Vision Science, Shahid Beheshti University of Medical Sciences, Tehran, Iran
| | - Seyed-Hossein Abtahi
- Ophthalmic Research Center, Research Institute for Ophthalmology and Vision Science, Shahid Beheshti University of Medical Sciences, Tehran, Iran
| |
Collapse
|
5
|
Meng Z, Chen S, Zhe N, Cao T, Li Z, Zhang Y, Wei R. Short-term Changes in Epithelial and Optical Redistribution Induced by Different Orthokeratology Designs. Eye Contact Lens 2023; 49:528-534. [PMID: 37902624 PMCID: PMC10659253 DOI: 10.1097/icl.0000000000001045] [Citation(s) in RCA: 1] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Accepted: 08/25/2023] [Indexed: 10/31/2023]
Abstract
OBJECTIVES This study aimed to investigate corneal epithelial and topographic changes caused by two commercial myopia orthokeratology (ortho-k) designs. METHODS Twenty-six subjects fitted with vision shape treatment (VST) lenses and 30 subjects fitted with corneal reshaping therapy (CRT) lenses were reviewed 1 day, 1 week, and 1 month after lens initiation. A spectral-domain optical coherence tomography system was used to create epithelial maps that were in turn used to determine the average epithelial thickness of each zone and the diameter of treatment zone. By measuring the topographic tangential differential map, the treatment zone diameter and the power and width of the high convex zone (HCZ) were obtained. All epithelial thicknesses and topographic corneal variations recorded were analyzed. RESULTS At the central zone, the epithelial thickness changes (△ET) decreased significantly after 1 day of ortho-k in two groups. At 2- to 9-mm peripheral zone, ortho-k increased △ET until 1 week in the VST group, whereas it kept increasing in the CRT group after 1 week. At 1 month, the central △ET is -9.51±2.38 mm in the VST group, which was comparable to -8.72±3.43 mm in the CRT group. The nasal HCZ power and the △ET of nasal and inferior nasal were significantly larger in the CRT group. A positive correlation was found between the HCZ power and △ET generated by VST-type lenses inferiorly and temporally. For the CRT group, a positive correlation was found between inferior HCZ power and △ET. CONCLUSIONS At the early stage of ortho-k, epithelial thickness and topography change quickly and simultaneously. Epithelial changes were in line with corneal topography reshaping. Epithelial and optical remodelling were affected by different lens types.
Collapse
Affiliation(s)
- Ziqi Meng
- Tianjin Key Laboratory of Retinal Functions and Diseases (Z.M., R.W.), Tianjin Branch of National Clinical Research Center for Ocular Disease, Eye Institute and School of Optometry, Tianjin Medical University Eye Hospital, Tianjin, China; Eye Hospital and School of Ophthalmology and Optometry (Z.M., S.C., N.Z., Z.L., Y.Z.), Wenzhou Medical University, Wenzhou, China; National Clinical Research Center for Ocular Diseases, Wenzhou, China; Eye Hospital of Wenzhou Medical University Hangzhou Branch, Hangzhou, China; and Mailman School of Public Health (T.C.), Columbia University Irving Medical Center, New York, NY
| | - Siping Chen
- Tianjin Key Laboratory of Retinal Functions and Diseases (Z.M., R.W.), Tianjin Branch of National Clinical Research Center for Ocular Disease, Eye Institute and School of Optometry, Tianjin Medical University Eye Hospital, Tianjin, China; Eye Hospital and School of Ophthalmology and Optometry (Z.M., S.C., N.Z., Z.L., Y.Z.), Wenzhou Medical University, Wenzhou, China; National Clinical Research Center for Ocular Diseases, Wenzhou, China; Eye Hospital of Wenzhou Medical University Hangzhou Branch, Hangzhou, China; and Mailman School of Public Health (T.C.), Columbia University Irving Medical Center, New York, NY
| | - Nan Zhe
- Tianjin Key Laboratory of Retinal Functions and Diseases (Z.M., R.W.), Tianjin Branch of National Clinical Research Center for Ocular Disease, Eye Institute and School of Optometry, Tianjin Medical University Eye Hospital, Tianjin, China; Eye Hospital and School of Ophthalmology and Optometry (Z.M., S.C., N.Z., Z.L., Y.Z.), Wenzhou Medical University, Wenzhou, China; National Clinical Research Center for Ocular Diseases, Wenzhou, China; Eye Hospital of Wenzhou Medical University Hangzhou Branch, Hangzhou, China; and Mailman School of Public Health (T.C.), Columbia University Irving Medical Center, New York, NY
| | - Tongxin Cao
- Tianjin Key Laboratory of Retinal Functions and Diseases (Z.M., R.W.), Tianjin Branch of National Clinical Research Center for Ocular Disease, Eye Institute and School of Optometry, Tianjin Medical University Eye Hospital, Tianjin, China; Eye Hospital and School of Ophthalmology and Optometry (Z.M., S.C., N.Z., Z.L., Y.Z.), Wenzhou Medical University, Wenzhou, China; National Clinical Research Center for Ocular Diseases, Wenzhou, China; Eye Hospital of Wenzhou Medical University Hangzhou Branch, Hangzhou, China; and Mailman School of Public Health (T.C.), Columbia University Irving Medical Center, New York, NY
| | - Zhangliang Li
- Tianjin Key Laboratory of Retinal Functions and Diseases (Z.M., R.W.), Tianjin Branch of National Clinical Research Center for Ocular Disease, Eye Institute and School of Optometry, Tianjin Medical University Eye Hospital, Tianjin, China; Eye Hospital and School of Ophthalmology and Optometry (Z.M., S.C., N.Z., Z.L., Y.Z.), Wenzhou Medical University, Wenzhou, China; National Clinical Research Center for Ocular Diseases, Wenzhou, China; Eye Hospital of Wenzhou Medical University Hangzhou Branch, Hangzhou, China; and Mailman School of Public Health (T.C.), Columbia University Irving Medical Center, New York, NY
| | - Yunjie Zhang
- Tianjin Key Laboratory of Retinal Functions and Diseases (Z.M., R.W.), Tianjin Branch of National Clinical Research Center for Ocular Disease, Eye Institute and School of Optometry, Tianjin Medical University Eye Hospital, Tianjin, China; Eye Hospital and School of Ophthalmology and Optometry (Z.M., S.C., N.Z., Z.L., Y.Z.), Wenzhou Medical University, Wenzhou, China; National Clinical Research Center for Ocular Diseases, Wenzhou, China; Eye Hospital of Wenzhou Medical University Hangzhou Branch, Hangzhou, China; and Mailman School of Public Health (T.C.), Columbia University Irving Medical Center, New York, NY
| | - Ruihua Wei
- Tianjin Key Laboratory of Retinal Functions and Diseases (Z.M., R.W.), Tianjin Branch of National Clinical Research Center for Ocular Disease, Eye Institute and School of Optometry, Tianjin Medical University Eye Hospital, Tianjin, China; Eye Hospital and School of Ophthalmology and Optometry (Z.M., S.C., N.Z., Z.L., Y.Z.), Wenzhou Medical University, Wenzhou, China; National Clinical Research Center for Ocular Diseases, Wenzhou, China; Eye Hospital of Wenzhou Medical University Hangzhou Branch, Hangzhou, China; and Mailman School of Public Health (T.C.), Columbia University Irving Medical Center, New York, NY
| |
Collapse
|
6
|
Kim H, Lee W, Kim YA, Yu S, Jeong J, Choi Y, Lee Y, Park YH, Kang MS, Kim MS, Kim TG. RNA-Sequencing Analysis Reveals the Role of Mitochondrial Energy Metabolism Alterations and Immune Cell Activation in Form-Deprivation and Lens-Induced Myopia in Mice. Genes (Basel) 2023; 14:2163. [PMID: 38136985 PMCID: PMC10743199 DOI: 10.3390/genes14122163] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/07/2023] [Revised: 11/27/2023] [Accepted: 11/28/2023] [Indexed: 12/24/2023] Open
Abstract
Myopia is a substantial global public health concern primarily linked to the elongation of the axial length of the eyeball. While numerous animal models have been employed to investigate myopia, the specific contributions of genetic factors and the intricate signaling pathways involved remain incompletely understood. In this study, we conducted RNA-seq analysis to explore genes and pathways in two distinct myopia-inducing mouse models: form-deprivation myopia (FDM) and lens-induced myopia (LIM). Comparative analysis with a control group revealed significant differential expression of 2362 genes in FDM and 503 genes in LIM. Gene Set Enrichment Analysis (GSEA) identified a common immune-associated pathway between LIM and FDM, with LIM exhibiting more extensive interactions. Notably, downregulation was observed in OxPhos complex III of FDM and complex IV of LIM. Subunit A of complex I was downregulated in LIM but upregulated in FDM. Additionally, complex V was upregulated in LIM but downregulated in FDM. These findings suggest a connection between alterations in energy metabolism and immune cell activation, shedding light on a novel avenue for understanding myopia's pathophysiology. Our research underscores the necessity for a comprehensive approach to comprehending myopia development, which integrates insights from energy metabolism, oxidative stress, and immune response pathways.
Collapse
Affiliation(s)
- Hojung Kim
- Translational-Transdisciplinary Research Center, Clinical Research Institute, Kyung Hee University Hospital at Gangdong, Kyung Hee University College of Medicine, Seoul 05278, Republic of Korea; (H.K.); (W.L.); (Y.-A.K.); (S.Y.); (J.J.); (Y.C.); (Y.L.)
| | - Wonmin Lee
- Translational-Transdisciplinary Research Center, Clinical Research Institute, Kyung Hee University Hospital at Gangdong, Kyung Hee University College of Medicine, Seoul 05278, Republic of Korea; (H.K.); (W.L.); (Y.-A.K.); (S.Y.); (J.J.); (Y.C.); (Y.L.)
- Department of Medicine, Kyung Hee University College of Medicine, Seoul 02453, Republic of Korea
| | - Ye-Ah Kim
- Translational-Transdisciplinary Research Center, Clinical Research Institute, Kyung Hee University Hospital at Gangdong, Kyung Hee University College of Medicine, Seoul 05278, Republic of Korea; (H.K.); (W.L.); (Y.-A.K.); (S.Y.); (J.J.); (Y.C.); (Y.L.)
- Department of Biomedical Science and Technology, Graduate School, Kyung Hee University, Seoul 02453, Republic of Korea
| | - Sanghyeon Yu
- Translational-Transdisciplinary Research Center, Clinical Research Institute, Kyung Hee University Hospital at Gangdong, Kyung Hee University College of Medicine, Seoul 05278, Republic of Korea; (H.K.); (W.L.); (Y.-A.K.); (S.Y.); (J.J.); (Y.C.); (Y.L.)
- Department of Biomedical Science and Technology, Graduate School, Kyung Hee University, Seoul 02453, Republic of Korea
| | - Jisu Jeong
- Translational-Transdisciplinary Research Center, Clinical Research Institute, Kyung Hee University Hospital at Gangdong, Kyung Hee University College of Medicine, Seoul 05278, Republic of Korea; (H.K.); (W.L.); (Y.-A.K.); (S.Y.); (J.J.); (Y.C.); (Y.L.)
- Department of Biomedical Science and Technology, Graduate School, Kyung Hee University, Seoul 02453, Republic of Korea
| | - Yueun Choi
- Translational-Transdisciplinary Research Center, Clinical Research Institute, Kyung Hee University Hospital at Gangdong, Kyung Hee University College of Medicine, Seoul 05278, Republic of Korea; (H.K.); (W.L.); (Y.-A.K.); (S.Y.); (J.J.); (Y.C.); (Y.L.)
- Department of Biomedical Science and Technology, Graduate School, Kyung Hee University, Seoul 02453, Republic of Korea
| | - Yoonsung Lee
- Translational-Transdisciplinary Research Center, Clinical Research Institute, Kyung Hee University Hospital at Gangdong, Kyung Hee University College of Medicine, Seoul 05278, Republic of Korea; (H.K.); (W.L.); (Y.-A.K.); (S.Y.); (J.J.); (Y.C.); (Y.L.)
| | - Yong Hwan Park
- Department of Microbiology, Ajou University School of Medicine, Suwon 16499, Republic of Korea;
| | - Min Seok Kang
- Department of Ophthalmology, Kyung Hee University Medical Center, Kyung Hee University College of Medicine, Seoul 02447, Republic of Korea;
| | - Man S. Kim
- Translational-Transdisciplinary Research Center, Clinical Research Institute, Kyung Hee University Hospital at Gangdong, Kyung Hee University College of Medicine, Seoul 05278, Republic of Korea; (H.K.); (W.L.); (Y.-A.K.); (S.Y.); (J.J.); (Y.C.); (Y.L.)
| | - Tae Gi Kim
- Department of Ophthalmology, Kyung Hee University Hospital at Gangdong, Kyung Hee University College of Medicine, Seoul 05278, Republic of Korea
| |
Collapse
|
7
|
Zhao GP, Zhai HT, Xiang HZ, Wu LM, Chen QO, Chen C, Zhou M. Biomechanical study of cornea response under orthokeratology lens therapy: A finite element analysis. INTERNATIONAL JOURNAL FOR NUMERICAL METHODS IN BIOMEDICAL ENGINEERING 2023; 39:e3691. [PMID: 36799066 DOI: 10.1002/cnm.3691] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 09/02/2022] [Accepted: 02/07/2023] [Indexed: 06/18/2023]
Abstract
Orthokeratology (OK) is becoming a mainstream modality for myopia correction and control, but its underlying mechanism is not yet fully understood. In this study, the biomechanical response of cornea under the OK lens was investigated to further understand the mechanism of OK therapy. Numerical models of the cornea and OK lens with different corneal refractive powers and myopia degrees were established to analyze features and differences of the spatial displacement and stress distribution in different areas of the anterior corneal surface by finite element method. Displacement distributions on the anterior cornea surface with refractive powers of 39.5, 43, 46 D, and myopia degrees of -1.0, -3.0, -6.0 D demonstrate similar deformation trends and nearly rotationally symmetrical attributes of different corneal parameters. Displacement of mid-peripheral cornea was significantly high compared with that of the central and peripheral cornea, peaking at ~2.4 mm off the corneal apex. The stress increased with the increase in myopia degrees and was significantly large for the myopia degrees of -6.0 D at S1; the stress at S2 and S6 was low and stable and did not differ much at S3; the stress at S4 and S5, however, was extremely high. In summary, simulation result of orthokeratology can effectively evaluate the performance of OK lens and it properly associates with the differential map of the corneal topography. The base curve of the OK lens may also play a role in mid-peripheral corneal steepening. The design around the OK lens' alignment curve needs to be optimized.
Collapse
Affiliation(s)
- Gai-Ping Zhao
- School of Health Science and Engineering, University of Shanghai for Science and Technology, Shanghai, China
| | - Hai-Tao Zhai
- School of Health Science and Engineering, University of Shanghai for Science and Technology, Shanghai, China
| | - Hua-Zhong Xiang
- School of Health Science and Engineering, University of Shanghai for Science and Technology, Shanghai, China
| | - Li-Ming Wu
- School of Health Science and Engineering, University of Shanghai for Science and Technology, Shanghai, China
| | - Qi-Ou Chen
- MicroPort Vision Power MedTech (Shanghai) Co., Ltd, Shanghai, China
| | - Chi Chen
- MicroPort Vision Power MedTech (Shanghai) Co., Ltd, Shanghai, China
| | - Meng Zhou
- MicroPort Vision Power MedTech (Shanghai) Co., Ltd, Shanghai, China
| |
Collapse
|
8
|
Pérez-Corral J, Cardona G, Piñero DP, Barroso D, Armadans L. Short- and mid-term changes in CORVIS ST parameters in successful, adult orthokeratology patients. Clin Exp Optom 2023; 106:726-733. [PMID: 36375143 DOI: 10.1080/08164622.2022.2140031] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/27/2022] [Revised: 07/12/2022] [Accepted: 10/20/2022] [Indexed: 11/16/2022] Open
Abstract
CLINICAL RELEVANCE The changes in various biomechanical and tomographic characteristics of the cornea associated with orthokeratology may allow us to identify potential mid- and long-term structural alterations, resulting in a better understanding of the governing mechanisms of this procedure and in its optimisation. BACKGROUND The study aimed at describing short and mid-term changes in CORVIS ST® parameters and indices in orthokeratology (ortho-k), and their diurnal variations. METHODS A prospective observational study was designed in which several CORVIS ST® parameters of 75 new adult participants successfully fitted with overnight ortho-k Seefree® (Conóptica - Hecht Contactlinsen) contact lenses were explored. Measurements were conducted in baseline (BL) conditions and in the morning and evening at the one-night (1 NM/1NT), one-week (1WM/1 WT) and 3-month (3 MM/3MT) follow-up visits. RESULTS Statistically significant differences were found in DARatio_2 mm, IntRad, ARTh, CBI and TBI following overnight ortho-k, when compared with BL values, with most values reaching stability at 1WM or reverting to BL values at 3 MM. The ARTh and CBI parameters showed some of the most significant temporal variations (both p < 0.001), probably reflecting the encountered differences in central corneal thickness between BL and 1WM (p = 0.010) and between BL and 3 MM (p = 0.016). In general, corneal rigidity was higher in the morning at all follow-up visits, and decreased during the day. No statistically significant changes in adjusted intraocular pressure values were found. CONCLUSION Ortho-k in adults may be considered a safe procedure in terms of short and mid-term changes in CORVIS ST® parameters. The observed alterations in most of the parameters provided by the Corvis ST® probably responded to the well-described changes in corneal pachymetry and tomography, rather than to actual alterations in corneal rigidity.
Collapse
Affiliation(s)
- Joan Pérez-Corral
- School of Optics and Optometry, Department of Optics and Optometry, Universitat Politècnica de Catalunya, Terrassa, Spain
| | - Genis Cardona
- School of Optics and Optometry, Department of Optics and Optometry, Universitat Politècnica de Catalunya, Terrassa, Spain
| | - David P Piñero
- Department of Optics, Pharmacology and Anatomy, University of Alicante, Alicante, Spain
| | - David Barroso
- School of Optics and Optometry, Department of Optics and Optometry, Universitat Politècnica de Catalunya, Terrassa, Spain
| | - Laura Armadans
- School of Optics and Optometry, Department of Optics and Optometry, Universitat Politècnica de Catalunya, Terrassa, Spain
| |
Collapse
|
9
|
Al-Mahrouqi H, Cheung IMY, Angelo L, Yu TY, Gokul A, Ziaei M. Therapeutic non-ectasia applications of cornea cross-linking. Clin Exp Optom 2023; 106:580-590. [PMID: 36690333 DOI: 10.1080/08164622.2022.2159790] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/05/2022] [Revised: 08/28/2022] [Accepted: 10/10/2022] [Indexed: 01/25/2023] Open
Abstract
Corneal cross-linking is a photopolymerization technique traditionally used to strengthen corneal tissue. Corneal cross-linking utilizes riboflavin (vitamin B2) as a photosensitizer and ultraviolet-A light (UVA) to create strong covalent bonds within the corneal stroma, increasing tissue stiffness. Multiple studies have demonstrated corneal cross-linking's effectiveness in treating corneal ectasia, a progressive, degenerative, and non-inflammatory thinning disorder, as quantified by key tomographic, refractive, and visual parameters. Since its introduction two decades ago, corneal cross-linking has surpassed its original application in halting corneal ectatic disease and its application has expanded into several other areas. Corneal cross-linking also possesses antibacterial, antienzymolytic and antioedematous properties, and has since become a tool in treating microbial keratitis, correcting refractive error, preventing iatrogenic ectasia, stabilising bullous keratopathy and controlling post keratoplasty ametropia. This review provides an overview of the current evidence base for the therapeutic non-ectasia applications of cornea cross-linking and looks at future developments in the field.
Collapse
Affiliation(s)
| | | | - Lize Angelo
- Department of Ophthalmology, University of Auckland, Auckland, New Zealand
| | - Tzu-Ying Yu
- Department of Ophthalmology, Greenlane Clinical Centre, Auckland District Health Board, Auckland, New Zealand
| | - Akilesh Gokul
- Department of Ophthalmology, University of Auckland, Auckland, New Zealand
| | - Mohammed Ziaei
- Department of Ophthalmology, University of Auckland, Auckland, New Zealand
| |
Collapse
|
10
|
Mahmoud O, Andrews C, Soeken T, Nallasamy S, Nallasamy N. Optical Biometry Changes Throughout Childhood and Adolescence in Patients Wearing Ortho-K Lenses. Clin Ophthalmol 2023; 17:1919-1927. [PMID: 37425028 PMCID: PMC10329451 DOI: 10.2147/opth.s413810] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/11/2023] [Accepted: 06/08/2023] [Indexed: 07/11/2023] Open
Abstract
Background Orthokeratology has been shown to suppress progressive myopia in some children. We examine the changes in optical biometry parameters in orthokeratology (Ortho-K) patients, in a retrospective longitudinal study at a tertiary eye care center in Ann Arbor, MI, USA. Methods Optical biometry measurements obtained with the Lenstar LS 900 (Haag-Streit USA Inc, EyeSuite software version i9.1.0.0) were aggregated from 170 patients who had undergone Ortho-K for myopia correction between 5 and 20 years of age. Pre-intervention biometry measurements were compared with follow-up measurements done 6-18 months after initiation of Ortho-K. Linear mixed models were used to quantify associations in biometry changes with age of intervention allowing for correlation between measurements on two eyes of the same patient. Results A total of 91 patients were included in the study. Axial length increased through the age of 15.7 ± 0.84 years for Ortho-K patients at our center. The growth curve in our Ortho-K population was comparable to previously published normal growth curves in Wuhan and Germany populations. Corneal thickness and keratometry decreased at a stable rate regardless of age of intervention (-7.9 µm, 95% CI [-10.2, -5.7], p < 0.001). Conclusion In our population, Ortho-K did not appear to affect the overall trajectory of axial length progression when compared to normal growth curves, despite showing a previously described reduction in corneal thickness. As Ortho-K has been shown to have varying effects that differ from individual to individual, it continues to be important to reassess its effects on new populations to better understand its ideal uses.
Collapse
Affiliation(s)
- Ossama Mahmoud
- Kellogg Eye Center Department of Ophthalmology and Visual Sciences, University of Michigan, Ann Arbor, MI, USA
- School of Medicine, Wayne State University, Detroit, MI, USA
| | - Chris Andrews
- Kellogg Eye Center Department of Ophthalmology and Visual Sciences, University of Michigan, Ann Arbor, MI, USA
| | - Timothy Soeken
- Kellogg Eye Center Department of Ophthalmology and Visual Sciences, University of Michigan, Ann Arbor, MI, USA
| | - Sudha Nallasamy
- The Vision Center, Children’s Hospital Los Angeles, Los Angeles, CA, USA
- USC Roski Eye Institute, Keck School of Medicine of the University of Southern California, LA, California, USA
| | - Nambi Nallasamy
- Kellogg Eye Center Department of Ophthalmology and Visual Sciences, University of Michigan, Ann Arbor, MI, USA
- Department of Computational Medicine and Bioinformatics, University of Michigan, Ann Arbor, MI, USA
| |
Collapse
|
11
|
Modeling and Prediction of the Immediate and Short-Term Effect of Myopic Orthokeratology. Eye Contact Lens 2023; 49:77-82. [PMID: 36694311 DOI: 10.1097/icl.0000000000000962] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Accepted: 10/22/2022] [Indexed: 01/26/2023]
Abstract
PURPOSE To characterize the clinical changes occurring in the initial phase of the orthokeratology (OK) treatment for myopia correction, developing a model of prediction of the refractive changes in such phase. METHODS Prospective study enrolling 64 eyes of 32 patients (range, 20-40 years) undergoing myopic OK treatment with the reverse geometry contact lens CRT (Paragon Vision Science). Changes in uncorrected visual acuity (UCVA) and best-corrected visual acuity (BCVA), refraction, corneal topography, ocular aberrations, and corneal epithelial thickness were evaluated during the first hour of OK lens wear and after 1 week of OK treatment. Multiple linear regression analysis was used to obtain a model to predict the short-term refractive effect of OK. RESULTS The UCVA improved at each visit, reaching normal visual acuity values after a week (P<0.001) of OK treatment, which was consistent with the significant spherical equivalent (SE) reduction and central flattening (P<0.001). Multiple linear regression analysis revealed that one night change in refraction (ΔR×1N) could be predicted according to the following expression (P<0.001, R2=0.686): ΔR×1N=1.042+0.028×Age+1.014×BCET (baseline central epithelium thickness)-0.752×BKm (baseline mean keratometry)-1.405×BSE (baseline SE)+1.032×ΔR×1 h (change in SE after 1 hr of OK lens use). Similarly, a statistically relevant linear relationship was obtained for predicting the refractive change after 1 week (ΔR×1W) of OK use (P<0.001, R2=0.928): ΔR×1W=3.470-1.046×BSE-1.552×BBCVA (baseline BCVA)-0.391×BKm+0.450×ΔR×1 h. CONCLUSIONS The immediate and short-term refractive effects of myopic OK with the reverse geometry contact lens CRT can be predicted with enough accuracy from baseline and first trial visits data.
Collapse
|
12
|
Changes in corneal thickness, corneal volume, and densitometry after long-term orthokeratology wear. Cont Lens Anterior Eye 2023; 46:101703. [PMID: 35550858 DOI: 10.1016/j.clae.2022.101703] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/30/2020] [Revised: 04/23/2022] [Accepted: 04/29/2022] [Indexed: 01/18/2023]
Abstract
PURPOSE To investigate changes in the corneal volume, corneal densitometry and pachymetry of young myopes wearing over-night orthokeratology (OK) contact lenses. METHODS The medical records of 28 right eyes of young myopes wearing OK between 2013 and 2018 were reviewed retrospectively. The baseline refractive error, best corrected visual acuities at baseline and uncorrected visual acuity at the most recent visit were recorded. Corneal volume of the central 10 mm cornea; densitometry at central, nasal and temporal cornea; and pachymetry along the horizontal and vertical meridians were collected from the Pentacam® HR at baseline, after one night of lens wear, and at the latest visit. RESULTS The mean age of subjects was 12.03 ± 3.80 years at the time of OK lens fitting and wore OK overnight for a mean duration of 666 days (range 206-1736 days). The baseline spherical equivalent refractive error was -3.03 ± 1.56 D (range -1.00 to -6.00 D). The corneal volume increased significantly after OK wear (p = 0.001). Corneal densitometry increased after OK wear, but the change did not reach statistical significance (p = 0.113). Pachymetry in the central cornea did not change significantly across all visits (p > 0.05) but increased significantly in the mid-peripheral regions of the cornea. Baseline refractive error was not found to be correlated with the changes in corneal volume, corneal densitometry, or pachymetry. CONCLUSION The increase in corneal volume and densitometry and no significant change in the central corneal thickness may indicate the presence of corneal oedema from long-term OK wear. The baseline refraction was not correlated with the changes in corneal volume, densitometry or pachymetry.
Collapse
|
13
|
Su B, Bao Z, Guo Y, Zheng H, Zhou J, Lu F, Jiang J. Changes in Shape Discrimination Sensitivity Under Glare Conditions After Orthokeratology in Myopic Children: A Prospective Study. Invest Ophthalmol Vis Sci 2023; 64:6. [PMID: 36626175 PMCID: PMC9838587 DOI: 10.1167/iovs.64.1.6] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/11/2023] Open
Abstract
Purpose To investigate changes in shape discrimination under mesopic conditions with and without glare after orthokeratology in myopic children. Methods This prospective study included 79 eyes of 79 myopic children (ages: 8-16 years). Shape discrimination thresholds (SDTs) were measured using radial frequency patterns, with a radial frequency of 4 cycles/360°, a peak spatial frequency of 3 cycles per degree, a contrast of 20%, and a mean radius of 1.5 degrees. SDT under mesopic conditions with and without glare was measured before orthokeratology and again at 1 week and 1 month after orthokeratology. Changes in the SDTs and their relationships to baseline ocular parameters were analyzed. Results SDTs with glare decreased significantly at 1 week (-0.08 ± 0.15 log(arcsec), P < 0.001) and 1 month (-0.09 ± 0.15 log(arcsec), P < 0.001) after orthokeratology. SDTs without glare remained stable (P = 0.81 and P = 1.00, respectively). The difference between SDTs with and without glare also decreased significantly at 1 week (-0.10 ± 0.17 log(arcsec), P < 0.001) and at 1 month (-0.08 ± 0.18 log(arcsec), P = 0.001) after orthokeratology. Based on a multivariate analysis, the greater decrease in SDT with glare after 1 month of orthokeratology was associated with a higher baseline spherical equivalent refraction. Conclusions Orthokeratology resulted in improved shape discrimination in myopic children under mesopic conditions but only when measured in the presence of glare.
Collapse
Affiliation(s)
- Binbin Su
- Eye Hospital and School of Ophthalmology and Optometry, Wenzhou Medical University, Wenzhou, China,National Clinical Research Center for Ocular Diseases, Wenzhou, China
| | - Zhishu Bao
- Eye Hospital and School of Ophthalmology and Optometry, Wenzhou Medical University, Wenzhou, China,National Clinical Research Center for Ocular Diseases, Wenzhou, China
| | - Yue Guo
- Eye Hospital and School of Ophthalmology and Optometry, Wenzhou Medical University, Wenzhou, China
| | - Huihu Zheng
- Eye Hospital and School of Ophthalmology and Optometry, Wenzhou Medical University, Wenzhou, China
| | - Jiawei Zhou
- Eye Hospital and School of Ophthalmology and Optometry, Wenzhou Medical University, Wenzhou, China,National Clinical Research Center for Ocular Diseases, Wenzhou, China
| | - Fan Lu
- Eye Hospital and School of Ophthalmology and Optometry, Wenzhou Medical University, Wenzhou, China,National Clinical Research Center for Ocular Diseases, Wenzhou, China
| | - Jun Jiang
- Eye Hospital and School of Ophthalmology and Optometry, Wenzhou Medical University, Wenzhou, China,National Clinical Research Center for Ocular Diseases, Wenzhou, China
| |
Collapse
|
14
|
Avetisov SE, Musaeva GM, Bubnova IA. [Effect of conventional and orthokeratological hard contact lenses on anatomical and functional characteristics of the cornea]. Vestn Oftalmol 2023; 139:7-15. [PMID: 36924510 DOI: 10.17116/oftalma20231390117] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 03/18/2023]
Abstract
Contact lenses are widely used for correction of myopia due to their accessibility, effectiveness and relative safety. PURPOSE This study evaluated the potential effects of conventional hard contact lenses (HCL) and orthokeratological contact lenses (OKL) on anatomical and functional condition of the cornea in myopia correction. MATERIAL AND METHODS The study included 80 patients (159 eyes) with low, moderate and high myopia. Group 1 consisted of 40 patients (79 eyes) who used conventional HCL; group 2 included 40 patients (80 eyes) who used OKL. All patients underwent topographic keratometry, corneal pachymetry mapping (Pentacam, Oculus, Germany; Visante OCT, Carl Zeiss, Germany), high-order aberrometry (OPD Scan, Nidek, Japan), confocal microscopy (Confoscan 4, Nidek, Japan), evaluation of corneal biomechanical properties (ORA, Reichert Technologies, USA) and corneal light scattering (Pentacam, Oculus, Germany). Examinations were taken before the treatment started and after 8-12 months of contact lens wear. RESULTS Group 1 showed corneal thickness increase in all zones (by 0.9-1.1%), no significant changes in corneal refraction, and increase in corneal hysteresis and corneal resistance factor. OKL wear led to a significant flattening of anterior surface of the cornea and steepening of its paracentral area, decrease in central corneal thickness (by 2.8%) and increase in mid-peripheral thickness (by 2.2%). No significant changes in posterior corneal surface were observed in the study patients. More significant increase in higher-order aberrations and the degree of light scattering was observed in group 2, while changes in subepithelial nerve plexus and stromal structure were more significant in group 1. CONCLUSION Long-term OKL wear shows more significant morphological and functional corneal changes compared to RGP lens.
Collapse
Affiliation(s)
- S E Avetisov
- Krasnov Research Institute of Eye Disease, Moscow, Russia.,I.M. Sechenov First Moscow State Medical University (Sechenov University), Moscow, Russia
| | - G M Musaeva
- I.M. Sechenov First Moscow State Medical University (Sechenov University), Moscow, Russia
| | - I A Bubnova
- Krasnov Research Institute of Eye Disease, Moscow, Russia
| |
Collapse
|
15
|
Yang S, Zhang J, Tan Y, Wang Y. Unraveling the mechanobiology of cornea: From bench side to the clinic. Front Bioeng Biotechnol 2022; 10:953590. [PMID: 36263359 PMCID: PMC9573972 DOI: 10.3389/fbioe.2022.953590] [Citation(s) in RCA: 5] [Impact Index Per Article: 2.5] [Reference Citation Analysis] [Abstract] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/26/2022] [Accepted: 09/06/2022] [Indexed: 11/18/2022] Open
Abstract
The cornea is a transparent, dome-shaped structure on the front part of the eye that serves as a major optic element and a protector from the external environment. Recent evidence shows aberrant alterations of the corneal mechano-environment in development and progression of various corneal diseases. It is, thus, critical to understand how corneal cells sense and respond to mechanical signals in physiological and pathological conditions. In this review, we summarize the corneal mechano-environment and discuss the impact of these mechanical cues on cellular functions from the bench side (in a laboratory research setting). From a clinical perspective, we comprehensively review the mechanical changes of corneal tissue in several cornea-related diseases, including keratoconus, myopia, and keratectasia, following refractive surgery. The findings from the bench side and clinic underscore the involvement of mechanical cues in corneal disorders, which may open a new avenue for development of novel therapeutic strategies by targeting corneal mechanics.
Collapse
Affiliation(s)
- Shu Yang
- Clinical College of Ophthalmology, Tianjin Medical University, Tianjin, China
- Tianjin Eye Institute, Tianjin Key Lab of Ophthalmology and Visual Science, Tianjin Eye Hospital, Tianjin, China
- Department of Ophthalmology, The First People’s Hospital of Huzhou, Huzhou, Zhejiang, China
| | - Jing Zhang
- Clinical College of Ophthalmology, Tianjin Medical University, Tianjin, China
- Tianjin Eye Institute, Tianjin Key Lab of Ophthalmology and Visual Science, Tianjin Eye Hospital, Tianjin, China
- School of Optometry, Hong Kong Polytechnic University, Hong Kong SAR, China
| | - Youhua Tan
- Hong Kong Polytechnic University Shenzhen Research Institute, Shenzhen, China
- Department of Biomedical Engineering, Hong Kong Polytechnic University, Hong Kong SAR, China
- *Correspondence: Youhua Tan, ; Yan Wang,
| | - Yan Wang
- Clinical College of Ophthalmology, Tianjin Medical University, Tianjin, China
- Tianjin Eye Institute, Tianjin Key Lab of Ophthalmology and Visual Science, Tianjin Eye Hospital, Tianjin, China
- *Correspondence: Youhua Tan, ; Yan Wang,
| |
Collapse
|
16
|
López García Rosuero M, Arranz Bombin A, Romero R, Hornero R, Martin R. Clinical tool to measure fluorescein patterns in orthokeratology. PeerJ 2022; 10:e14068. [PMID: 36172500 PMCID: PMC9512001 DOI: 10.7717/peerj.14068] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/28/2022] [Accepted: 08/26/2022] [Indexed: 01/20/2023] Open
Abstract
Background Orthokeratology (ortho-k) is an overnight clinical contact lens wear technique to correct myopia and to reduce myopia progression wearing reverse-geometry rigid gas-permeable lenses. The lens fitting procedure in clinical practice usually requires subjective assessment of fluorescein pattern (fluorescein "bull's eye" pattern). The aim of this study was to develop a novel tool for fluorescein pattern measurements to reduce subjective practitioner dependency, especially in inexperienced practitioners, in ortho-k practice. Methods A new MATLAB customized algorithm to measure the horizontal width of the four main zones of ortho-k fluorescein patterns (central bearing, tear reservoir, mid-peripheral bearing and edge lift) was designed. The algorithm was tested on a small image database consisting of 26 ortho-k fluorescein pattern images of 13 volunteers fitted with reverse geometry lenses (Seefree, Conoptica-Hecht Contactlinsen). The agreement between two independent observers and the ImageJ measurements was determined. Results The new clinical tool provided similar measurements to ImageJ software for the central bearing (4.20 ± 0.74 and 4.27 ± 0.69 mm; P = 0.21), tear reservoir (1.69 ± 0.41 and 1.69 ± 0.45 mm; P = 0.69), mid-peripheral bearing (1.17 ± 0.11 and 1.13 ± 0.10 mm; P < 0.01) and edge lift (0.48 ± 0.06 and 0.48 ± 0.06 mm; P = 0.81) zones. Good agreement between the software (limits of agreement lower than ±0.55 mm) and inter-observer measurements (limits of agreement lower than ±0.66 mm) was found. Conclusions The proposed clinical tool for semiautomatic fluorescein pattern measurements in ortho-k could help to reduce practitioner dependency in fluorescein pattern assessment with future potential to introduce prediction algorithms or artificial intelligence methods in myopia control management.
Collapse
Affiliation(s)
| | | | - Roberto Romero
- Biomedical Engineering Group, Universidad de Valladolid, Valladolid, Spain
| | - Roberto Hornero
- Biomedical Engineering Group, Universidad de Valladolid, Valladolid, Spain
| | - Raul Martin
- School of Optometry, Universidad de Valladolid, Valladolid, Spain,Biomedical Engineering Group, Universidad de Valladolid, Valladolid, Spain,IOBA Eye Institute, Universidad de Valladolid, Valladolid, Spain
| |
Collapse
|
17
|
Alghamdi A, Khan MS, Dakhil TA. Understanding Corneal Epithelial Thickness Mapping. Middle East Afr J Ophthalmol 2022; 29:147-155. [PMID: 37408717 PMCID: PMC10319081 DOI: 10.4103/meajo.meajo_207_22] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/08/2022] [Revised: 12/31/2022] [Accepted: 03/06/2023] [Indexed: 07/07/2023] Open
Abstract
Corneal epithelial thickness (CET) and the regional variations in response to changes in corneal architecture and biomechanics have recently drawn the interest of corneal surgeons. Corneal epithelium possesses the tremendous capability of remodeling and changing its thickness. This remodeling of corneal epithelium takes place in response to underlying stromal irregularities which can result from a variety of corneal disorders including corneal ectasia. Measurement of CET can reveal the underlying stromal abnormalities and supplement in early diagnosis of corneal disorders especially corneal ectasia which has been one of the leading challenges in planning corneal refractive surgery. A significant number of patients ends up in ectasia after refractive surgery and the most common cause of this complication is the presence of preoperative subclinical keratoconus. Furthermore, postoperative complications of corneal refractive surgery are partly masked by epithelial remodeling and make the diagnosis and management difficult and extremely challenging. This leads not only to unpredictable visual and refractive outcome but also the need of multiple interventions to treat these complications. Although corneal tomography is considered as gold standard in the detection and diagnosis of corneal ectasia, a small number of subclinical cases may still go undetected. In this review, we have highlighted the underlying mechanism of epithelial remodeling, the devices and imaging modalities used to measure CET, and application of epithelial mapping in the diagnosis and management of various corneal disorders.
Collapse
Affiliation(s)
- Abdullah Alghamdi
- Department of Ophthalmology, Prince Sultan Military Medical City, Riyadh, Saudi Arabia
| | - Muhammad S. Khan
- Department of Ophthalmology, Prince Sultan Military Medical City, Riyadh, Saudi Arabia
| | - Turki A. Dakhil
- Department of Ophthalmology, Prince Sultan Military Medical City, Riyadh, Saudi Arabia
| |
Collapse
|
18
|
Li X, Xu J, Hong J, Yao J. The relationship between corneal biomechanical parameters and treatment outcomes of orthokeratology lenses. BMC Ophthalmol 2022; 22:262. [PMID: 35690754 PMCID: PMC9188053 DOI: 10.1186/s12886-022-02480-1] [Citation(s) in RCA: 4] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/13/2021] [Accepted: 05/03/2022] [Indexed: 11/15/2022] Open
Abstract
Background To evaluate changes in corneal biomechanical properties after long-term orthokeratology (OK) treatment and the factors affecting treatment outcomes. Methods Twenty-four myopic teenagers who wore OK lenses for more than 1 year were included. Twenty-three individuals of the same age and with the same spherical equivalent wearing single-vision spectacles (SVS) were enrolled as controls. After routine eye examinations, corneal biomechanical properties and axial length were measured. Parameters were compared between groups. Results Less axial elongation (AE) occurred in the OK group (P = 0.021). The OK group experienced a statistically significant decrease in the A1 deformation amplitude (P = 0.02), whole eye movement maximum (P = 0.026), and Ambrósio’s relational thickness to the horizontal profile (ARTh) (P < 0.001), and a statistically significant increase in the pachyslope (P < 0.001) and Corvis biomechanical index (P < 0.001). Smaller ARTh and a larger highest concavity deflection area resulted in a better refractive state. The inhibitory effect of AE was better for older patients with smaller ARTh. Conclusions Long-term OK treatment slowed myopia progression by reshaping the cornea. Smaller ARTh after OK lens wear indicated a better refractive state and slower AE and could predict OK lens treatment outcomes.
Collapse
Affiliation(s)
- Xia Li
- Department of Ophthalmology, Shanghai Aier Eye Hospital, Shanghai, China
| | - Jianjiang Xu
- Department of Ophthalmology and Visual Science, Shanghai Medical College, Eye, Ear, Nose, and Throat Hospital, Fudan University, No. 83 Fenyang Road, Xuhui District, Shanghai, 200031, China.,Key Laboratory of Myopia of State Health Ministry and Key Laboratory of Visual Impairment and Restoration of Shanghai, Eye, Ear, Nose and Throat Hospital, Fudan University, Shanghai, China
| | - Jiaxu Hong
- Department of Ophthalmology and Visual Science, Shanghai Medical College, Eye, Ear, Nose, and Throat Hospital, Fudan University, No. 83 Fenyang Road, Xuhui District, Shanghai, 200031, China. .,Key Laboratory of Myopia of State Health Ministry and Key Laboratory of Visual Impairment and Restoration of Shanghai, Eye, Ear, Nose and Throat Hospital, Fudan University, Shanghai, China.
| | - Jing Yao
- Department of Ophthalmology and Visual Science, Shanghai Medical College, Eye, Ear, Nose, and Throat Hospital, Fudan University, No. 83 Fenyang Road, Xuhui District, Shanghai, 200031, China. .,Key Laboratory of Myopia of State Health Ministry and Key Laboratory of Visual Impairment and Restoration of Shanghai, Eye, Ear, Nose and Throat Hospital, Fudan University, Shanghai, China.
| |
Collapse
|
19
|
Wang A, Yang C, Shen L, Wang J, Zhang Z, Yang W. Axial length shortening after orthokeratology and its relationship with myopic control. BMC Ophthalmol 2022; 22:243. [PMID: 35659643 PMCID: PMC9164339 DOI: 10.1186/s12886-022-02461-4] [Citation(s) in RCA: 7] [Impact Index Per Article: 3.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/22/2021] [Accepted: 05/18/2022] [Indexed: 02/07/2023] Open
Abstract
Purpose To determine the pattern of axial variation in subjects with initial shortened axial length during the entire period of orthokeratology and to discuss the possibility of shortened AL after one month of orthokeratology becoming a predictor of myopia control. Method This study retrospectively included 106 children with myopia aged 8 to 14 wearing OK lenses. Fifty-four eyes with shortened axial length (AL) at the first-month visit were enrolled in the axial length shortening (ALS) group, and fifty-two eyes without shortened AL were enrolled in the no axial length shortening (NALS) group. Axial length and refractive error at baseline and within the entire period of orthokeratology (20 months), including fitting, washout period and re-wear, were measured. Eighty-five children who started wearing single vision spectacle were also included as a control group. Results In the ALS group, AL became longer after shortening and slowly exceeded baseline; afterward, AL experienced a rebound during the washout period and shortened again if OK lenses were re-worn. After washout period, significant difference in AL (ALS:0.28 ± 0.19 mm, NALS: 0.52 ± 0.17 mm) and spherical equivalent (ALS:-0.43 ± 0.44D, NALS:-0.91 ± 0.40D) between the two groups were found(P<0.05). The changes in AL and SE were both significantly correlated with the changes in AL at the first-month visit (P<0.05). Conclusion After AL is shortened in the initial stage of orthokeratology, it will experience a rapid rebound during the washout period, and the shortening can reappear when re-wearing OK lenses. Hence, the evaluation of orthokeratology will be more objective and accurate after the wash-out period. In addition, the existence and degree of axial shortening can be used as a predictor of long-term myopia development. Supplementary Information The online version contains supplementary material available at 10.1186/s12886-022-02461-4.
Collapse
|
20
|
Canestraro J, Hultcrantz M, Modi S, Hamlin PA, Shoushtari AN, Konner JA, Tew WP, Iyengar NM, Heinemann M, Abramson DH, Francis JH. Refractive Shifts and Changes in Corneal Curvature Associated With Antibody-Drug Conjugates. Cornea 2022; 41:792-801. [PMID: 34839332 PMCID: PMC9106803 DOI: 10.1097/ico.0000000000002934] [Citation(s) in RCA: 4] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/16/2021] [Accepted: 09/28/2021] [Indexed: 11/25/2022]
Abstract
PURPOSE Antibody-drug conjugates (ADCs) are a class of cancer drug wherein some are associated with corneal abnormalities, but there is a dearth of published information on refractive shifts in patients receiving ADCs. Here, we evaluated the dynamics of refractive error and keratometry readings in patients with ADC-related keratopathy and microcyst-like epithelial changes (MECs). METHODS This study is a retrospective case series including 58 eyes of 29 patients with ADC-related keratopathy from a single tertiary care cancer referral center (MSKCC). One eye (29 total) was randomly assigned for statistical analysis. In addition, a subset analysis of MEC location-refractive error correlation was performed on 20 eyes. Clinical records including slitlamp examination, indirect ophthalmoscopy, calculated spherical equivalence (SE), keratometry, and visual acuity were recorded at baseline, during, and off treatment. RESULTS A subset analysis of MEC location-refractive error correlation of 20 eyes revealed the following: Peripheral MECs were significantly associated with hyperopic shifts (P value < 0.001) and paracentral/central associated with myopic shifts (P value < 0.001). In the full cohort and on drug, the greatest change in SE from baseline was myopic (68%, as high as -4.75 D) and hyperopic (32%, as much as +3.75 D). Eighty-nine percent had a change in vision from baseline while on drug, but at the 3-month follow-up off drug, SE and vision returned to baseline in 33% and 82% of eyes. CONCLUSIONS Peripheral MECs were significantly associated with hyperopic shifts, and paracentral/central MECs were associated with myopic shifts. While on drug, most eyes had a myopic refractive shift, which corresponded with corneal steepening.
Collapse
Affiliation(s)
- Julia Canestraro
- Ophthalmic Oncology Service, Memorial Sloan Kettering Cancer Center, New York, NY, USA
| | - Malin Hultcrantz
- Myeloma Service, Memorial Sloan Kettering Cancer Center, New York, NY, USA
| | - Shanu Modi
- Department of Medicine, Memorial Sloan Kettering Cancer Center, New York, NY, USA
| | - Paul A Hamlin
- Department of Medicine, Memorial Sloan Kettering Cancer Center, New York, NY, USA
| | | | - Jason A Konner
- Department of Medicine, Memorial Sloan Kettering Cancer Center, New York, NY, USA
| | - William P Tew
- Department of Medicine, Memorial Sloan Kettering Cancer Center, New York, NY, USA
| | - Neil M Iyengar
- Department of Medicine, Memorial Sloan Kettering Cancer Center, New York, NY, USA
| | - Murk Heinemann
- Ophthalmic Oncology Service, Memorial Sloan Kettering Cancer Center, New York, NY, USA
- Weill Cornell Medical Center, New York, NY, USA
| | - David H Abramson
- Ophthalmic Oncology Service, Memorial Sloan Kettering Cancer Center, New York, NY, USA
- Weill Cornell Medical Center, New York, NY, USA
| | - Jasmine H Francis
- Ophthalmic Oncology Service, Memorial Sloan Kettering Cancer Center, New York, NY, USA
- Weill Cornell Medical Center, New York, NY, USA
| |
Collapse
|
21
|
Post-Ortho-K Corneal Epithelium Changes in Myopic Eyes. DISEASE MARKERS 2022; 2022:3361172. [PMID: 35677633 PMCID: PMC9168212 DOI: 10.1155/2022/3361172] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 03/07/2022] [Accepted: 05/08/2022] [Indexed: 11/18/2022]
Abstract
The study is aimed at evaluating corneal epithelial thickness changes associated with overnight orthokeratology (ortho-K). In this retrospective study, epithelial thickness was measured using optical coherence tomography (OCT) before and after 1 day, 1 week, 1 month, and 3 months ortho-K nightly lens wear. Compared with pre-orthokeratology measurements, central (2 mm) corneal epithelium thickness was significantly reduced at 1 day, 1 week, 1 month, and 3 months with ortho-K (P < 0.05). Paracentral (2 mm~5 mm annular ring) epithelial thickness was also significantly reduced at superior temporal, inferior temporal, temporal, and inferior locations after ortho-K (P < 0.05), while midperipheral (5 mm~6 mm annular ring) epithelial thickness was greater post- than pre-ortho-K at superior, superior temporal, inferior temporal, inferior, and inferior nasal locations (P < 0.05). In other zones, superior, superior nasal, nasal, and inferior nasal in paracentral annular ring and temporal and superior nasal in midperipheral ring, epithelial thickness underwent no significant change. Ortho-K lens wear caused the central corneal epitheliums to thin. The temporal half zones become thinner in paracentral zones and thicker in midperipheral zones.
Collapse
|
22
|
Kuo YK, Chen YT, Chen HM, Wu PC, Sun CC, Yeung L, Lin KK, Chen HC, Chuang LH, Lai CC, Chen YH, Liu CF. Efficacy of Myopia Control and Distribution of Corneal Epithelial Thickness in Children Treated with Orthokeratology Assessed Using Optical Coherence Tomography. J Pers Med 2022; 12:jpm12020278. [PMID: 35207766 PMCID: PMC8875657 DOI: 10.3390/jpm12020278] [Citation(s) in RCA: 8] [Impact Index Per Article: 4.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/26/2021] [Revised: 01/07/2022] [Accepted: 01/25/2022] [Indexed: 12/16/2022] Open
Abstract
The association between myopia control efficacy in children treated with orthokeratology and corneal epithelial thickness is still unknown. The aim of this study was to explore the corneal epithelial thickness and its association with axial length changes in children treated with orthokeratology. This retrospective cohort study enrolled children aged from 9 to 15 years who had received orthokeratology for myopia control and had been followed up for at least 1 year. Anterior segment optical coherence tomography was performed to generate wide epithelial thickness maps of the patients. Annual axial length changes were calculated from the axial length at 6 months after the initiation of orthokeratology lens wear and at final measurements. Corneal epithelial thickness data were obtained from 24 sectors and a central 2 mm zone of the wide epithelial thickness map. Associations between annual axial length changes and corneal epithelial thickness for each sector/zone of the wide epithelial thickness map, and orthokeratology treatment data were determined by generalized estimating equations. Finally, a total of 83 eyes of 43 patients (mean age 11.2 years) were included in the analysis. The mean annual axial length change was 0.169 mm; when regressing demographic and ortho-k parameters to mean annual axial length changes, age and target power were both negatively associated with them (β = −14.43, p = 0.008; β = −0.26, p = 0.008, respectively). After adjusting for age and target power, the annual axial length changes were positively associated with the corneal epithelium thickness of IT1, I1, SN2, and S2 sectors of the wide epithelial thickness map, and negatively with that of the I3 sector. In conclusion, we identified associations between annual axial length changes and the corneal epithelium thickness of certain sectors in children treated with orthokeratology. This may facilitate the design of orthokeratology lenses with enhanced efficacy for myopia control.
Collapse
Affiliation(s)
- Yu-Kai Kuo
- Department of Ophthalmology, Chang Gung Memorial Hospital, Keelung 20401, Taiwan; (Y.-K.K.); (H.-M.C.); (C.-C.S.); (L.Y.); (L.-H.C.); (C.-C.L.)
- College of Medicine, Chang Gung University, Taoyuan 33302, Taiwan; (Y.-T.C.); (P.-C.W.); (K.-K.L.); (H.-C.C.)
| | - Yen-Ting Chen
- College of Medicine, Chang Gung University, Taoyuan 33302, Taiwan; (Y.-T.C.); (P.-C.W.); (K.-K.L.); (H.-C.C.)
- Department of Ophthalmology, Chang Gung Memorial Hospital, Linkou 33305, Taiwan
| | - Ho-Min Chen
- Department of Ophthalmology, Chang Gung Memorial Hospital, Keelung 20401, Taiwan; (Y.-K.K.); (H.-M.C.); (C.-C.S.); (L.Y.); (L.-H.C.); (C.-C.L.)
- College of Medicine, Chang Gung University, Taoyuan 33302, Taiwan; (Y.-T.C.); (P.-C.W.); (K.-K.L.); (H.-C.C.)
| | - Pei-Chang Wu
- College of Medicine, Chang Gung University, Taoyuan 33302, Taiwan; (Y.-T.C.); (P.-C.W.); (K.-K.L.); (H.-C.C.)
- Department of Ophthalmology, Kaohsiung Chang Gung Memorial Hospital, Kaohsiung 83301, Taiwan
| | - Chi-Chin Sun
- Department of Ophthalmology, Chang Gung Memorial Hospital, Keelung 20401, Taiwan; (Y.-K.K.); (H.-M.C.); (C.-C.S.); (L.Y.); (L.-H.C.); (C.-C.L.)
- College of Medicine, Chang Gung University, Taoyuan 33302, Taiwan; (Y.-T.C.); (P.-C.W.); (K.-K.L.); (H.-C.C.)
| | - Ling Yeung
- Department of Ophthalmology, Chang Gung Memorial Hospital, Keelung 20401, Taiwan; (Y.-K.K.); (H.-M.C.); (C.-C.S.); (L.Y.); (L.-H.C.); (C.-C.L.)
- College of Medicine, Chang Gung University, Taoyuan 33302, Taiwan; (Y.-T.C.); (P.-C.W.); (K.-K.L.); (H.-C.C.)
| | - Ken-Kuo Lin
- College of Medicine, Chang Gung University, Taoyuan 33302, Taiwan; (Y.-T.C.); (P.-C.W.); (K.-K.L.); (H.-C.C.)
- Department of Ophthalmology, Chang Gung Memorial Hospital, Linkou 33305, Taiwan
| | - Hung-Chi Chen
- College of Medicine, Chang Gung University, Taoyuan 33302, Taiwan; (Y.-T.C.); (P.-C.W.); (K.-K.L.); (H.-C.C.)
- Department of Ophthalmology, Chang Gung Memorial Hospital, Linkou 33305, Taiwan
- Center for Tissue Engineering, Chang Gung Memorial Hospital, Linkou 33305, Taiwan
| | - Lan-Hsin Chuang
- Department of Ophthalmology, Chang Gung Memorial Hospital, Keelung 20401, Taiwan; (Y.-K.K.); (H.-M.C.); (C.-C.S.); (L.Y.); (L.-H.C.); (C.-C.L.)
- College of Medicine, Chang Gung University, Taoyuan 33302, Taiwan; (Y.-T.C.); (P.-C.W.); (K.-K.L.); (H.-C.C.)
| | - Chi-Chun Lai
- Department of Ophthalmology, Chang Gung Memorial Hospital, Keelung 20401, Taiwan; (Y.-K.K.); (H.-M.C.); (C.-C.S.); (L.Y.); (L.-H.C.); (C.-C.L.)
- College of Medicine, Chang Gung University, Taoyuan 33302, Taiwan; (Y.-T.C.); (P.-C.W.); (K.-K.L.); (H.-C.C.)
| | - Yau-Hung Chen
- Department of Chemistry, Tamkang University, Tamsui 251301, Taiwan;
| | - Chun-Fu Liu
- Department of Ophthalmology, Chang Gung Memorial Hospital, Keelung 20401, Taiwan; (Y.-K.K.); (H.-M.C.); (C.-C.S.); (L.Y.); (L.-H.C.); (C.-C.L.)
- College of Medicine, Chang Gung University, Taoyuan 33302, Taiwan; (Y.-T.C.); (P.-C.W.); (K.-K.L.); (H.-C.C.)
- Program in Molecular Medicine, National Yang Ming Chiao Tung University, Taipei 112304, Taiwan
- Correspondence: ; Tel.: +886-2-2431-3131
| |
Collapse
|
23
|
Zhao L, Jing L, Li J, Du X. Changes in corneal densitometry after long-term orthokeratology for myopia and short-term discontinuation. PLoS One 2022; 17:e0263121. [PMID: 35120161 PMCID: PMC8815901 DOI: 10.1371/journal.pone.0263121] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/28/2021] [Accepted: 01/12/2022] [Indexed: 11/18/2022] Open
Abstract
Purpose
To quantify changes in corneal densitometry after long-term orthokeratology treatment in myopic children and to analyze the reversibility one month after discontinuation.
Methods
Seventy-four myopic subjects aged 8–16 years, who wore orthokeratology lenses for two years, were divided into relatively steep- (lens movement within 1.0–1.5 mm, thirty-six participants) and flat-fitting groups (lens movement within 1.5–2.0 mm, thirty-eight participants). Based on refractive errors, they were divided into low and moderate myopia groups (thirty-seven participants in each group). Corneal densitometry was performed using Pentacam (Oculus Optikgeräte GmbH, Wetzlar, Germany) at each follow-up timepoint. Repeated-measures analysis of variance was used to compare the parameters before and after orthokeratology.
Results
The corneal densitometry values over the 0–10 mm diameter area increased from 12.84±1.38 grayscale units (GSU) at baseline to 13.59±1.42 GSU after three-month orthokeratology (P = .001) and reached 14.92±1.45 GSU at two years (P < .001). An increase in densitometry began at one month (P = .001) over the 0–2 mm annulus compared with that at three months over the 2–6 mm and 6–10 mm zones (P = .002,.014). The densitometry values significantly increased at three months in the relatively steep-fitting group (P = .003) and at one year in the relatively flat-fitting group (P = .001). After discontinuation of orthokeratology for one month, the values showed no significant decrease.
Conclusions
Long-term orthokeratology treatment causes a small but statistically significant increase in corneal densitometry values. During the first year, the onset of these changes was related to the fitting mode. Corneal densitometry values showed no significant reduction after one-month discontinuation.
Collapse
Affiliation(s)
- Lianghui Zhao
- Qingdao Eye Hospital of Shandong First Medical University, Qingdao, China
- State Key Laboratory Cultivation Base, Shandong Provincial Key Laboratory of Ophthalmology, Shandong Eye Institute, Shandong First Medical University & Shandong Academy of Medical Sciences, Qingdao, China
- Weifang Medical University, Weifang, China
| | - Lili Jing
- Qingdao Eye Hospital of Shandong First Medical University, Qingdao, China
- State Key Laboratory Cultivation Base, Shandong Provincial Key Laboratory of Ophthalmology, Shandong Eye Institute, Shandong First Medical University & Shandong Academy of Medical Sciences, Qingdao, China
| | - Jie Li
- Qingdao Eye Hospital of Shandong First Medical University, Qingdao, China
- State Key Laboratory Cultivation Base, Shandong Provincial Key Laboratory of Ophthalmology, Shandong Eye Institute, Shandong First Medical University & Shandong Academy of Medical Sciences, Qingdao, China
| | - Xianli Du
- Qingdao Eye Hospital of Shandong First Medical University, Qingdao, China
- State Key Laboratory Cultivation Base, Shandong Provincial Key Laboratory of Ophthalmology, Shandong Eye Institute, Shandong First Medical University & Shandong Academy of Medical Sciences, Qingdao, China
- * E-mail:
| |
Collapse
|
24
|
Hoshing A, Bhosale S, Samant M, Bamne A, Kalyankar H. A cross-sectional study to compare the normal corneal epithelial thickness in various age groups of Indian population using 9 mm wide optical coherence tomography scans. Indian J Ophthalmol 2022; 70:505-510. [PMID: 35086226 PMCID: PMC9023985 DOI: 10.4103/ijo.ijo_1621_21] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/10/2022] Open
Abstract
Purpose: To compare the corneal epithelial thickness among various age groups of normal Indians with 9-mm-wide optical coherence tomography scans. Methods: This cross sectional, observational study recruited patients in the age groups of 5–20 years (group 1), 21–35 years (group 2), 36–50 years (group 3), and more than 51 years (group 4). They underwent a detailed ophthalmic examination and were excluded if found to have any ocular surface or intraocular disease (except cataract and refractive error), undergone any ophthalmic surgery, corneal topography changes suggestive of corneal ectasias, or been continuously using any topical medication in either eye for a period of 3 months or more with the last instillation being within 1 month of inclusion in the study. Corneal epithelial thickness (CET) was measured using anterior segment optical coherence tomography (AS-OCT). The CET data from 25 sectors in each eye were analyzed for each age group. Results: There were 71 subjects in group 1, 76 subjects in group 2, 59 subjects in group 3, and 57 subjects in group 4. The mean (± standard deviation) ages in the groups 1, 2, 3, and 4 were 14.04 ± 5.10, 26.63 ± 4.71, 42.66 ± 3.92, and 61.65 ± 7.47 years, respectively. The central corneal thickness in all age groups was comparable. Maximum variance in CET parameters was seen in superior cornea. Conclusion: Central corneal thickness remains fairly stable over various age groups. The maximum variance in CET over age is seen in superior cornea. The findings from the Indian population correlate well with racially and geographically distinct subjects.
Collapse
Affiliation(s)
- Abhishek Hoshing
- Department of Cornea and Refractive Surgery, Laxmi Eye Institute, Panvela; Department of Ophthalmology, Apollo Hospitals, Navi Mumbai, Maharashtra, India
| | - Seema Bhosale
- Cataract Services, Laxmi Eye Institute, Panvel, Maharashtra, India
| | - Monica Samant
- Pediatric Ophthalmology, Strabismus and Neuro-Ophthalmology, Laxmi Eye Institute, Panvel, Maharashtra, India
| | - Aditya Bamne
- Clinical Optometry, Laxmi Eye Institute, Panvel, Maharashtra, India
| | - Huma Kalyankar
- Clinical Optometry, Laxmi Eye Institute, Panvel, Maharashtra, India
| |
Collapse
|
25
|
Ran Z, Moore J, Jiang F, Guo H, Eliasy A, Lopes BT, Bao F, Jiang J, Abass A, Elsheikh A. A new approach for quantifying epithelial and stromal thickness changes after orthokeratology contact lens wear. ROYAL SOCIETY OPEN SCIENCE 2021; 8:211108. [PMID: 34950488 PMCID: PMC8692962 DOI: 10.1098/rsos.211108] [Citation(s) in RCA: 6] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 07/23/2021] [Accepted: 11/29/2021] [Indexed: 05/03/2023]
Abstract
The aim of the study was to develop an automatic segmentation approach to optical coherence tomography (OCT) images and to investigate the changes in epithelial and stromal thickness profile and radius of curvature after the use of orthokeratology (Ortho-K) contact lenses. A total of 45 right eyes from 52 participants were monitored before, and after one month of, uninterrupted overnight Ortho-K lens wear. The tomography of their right eyes was obtained using optical OCT and rotating Scheimpflug imaging (OCULUS Pentacam). A custom-built MATLAB code for automatic segmentation of corneal OCT images was created and used to assess changes in epithelial thickness, stromal thickness, corneal and stromal profiles and radii of curvature before, and after one month of, uninterrupted overnight wear of Ortho-K lenses. In the central area (0-2 mm diameter), the epithelium thinned by 12.8 ± 6.0 µm (23.8% on average, p < 0.01) after one month of Ortho-K lens wear. In the paracentral area (2-5 mm diameter), the epithelium thinned nasally and temporally (by 2.4 ± 5.9 µm, 4.5% on average, p = 0.031). The stroma thickness increased in the central area (by 4.8 ± 16.1 µm, p = 0.005). The radius of curvature of the central corneal anterior surface increased by 0.24 ± 0.26 mm (3.1%, p < 0.01) along the horizontal meridian and by 0.34 ± 0.18 mm (4.2%, p < 0.01) along the vertical meridian. There were no significant changes in the anterior and posterior stromal radius of curvature. This study introduced a new method to automatically detect the anterior corneal surface, the epithelial posterior surface and the posterior corneal surface in OCT scans. Overnight wear of Ortho-K lenses caused thinning of the central corneal epithelium. The anterior corneal surface became flattered while the anterior and posterior surfaces of the stroma did not undergo significant changes. The results are consistent with the changes reported in previous studies. The reduction in myopic refractive error caused by Ortho-K lens wear was mainly due to changes in corneal epithelium thickness profile.
Collapse
Affiliation(s)
- Ziying Ran
- School of Engineering, University of Liverpool, Liverpool, UK
| | - Joshua Moore
- School of Engineering, University of Liverpool, Liverpool, UK
- Department of Mathematical Sciences, School of Physical Sciences, University of Liverpool, Liverpool, UK
| | - Fan Jiang
- Eye Hospital, Wenzhou Medical University, Wenzhou, People's Republic of China
| | - Hongmei Guo
- College of Biomedical Engineering, Taiyuan University of Technology, Taiyuan City, Shanxi Province, People's Republic of China
| | - Ashkan Eliasy
- School of Engineering, University of Liverpool, Liverpool, UK
| | - Bernardo T. Lopes
- School of Engineering, University of Liverpool, Liverpool, UK
- Federal University of São Paulo, 1500 Vila Clementino, São Paulo 04021-001, Brazil
| | - FangJun Bao
- Eye Hospital, Wenzhou Medical University, Wenzhou, People's Republic of China
| | - Jun Jiang
- Eye Hospital, Wenzhou Medical University, Wenzhou, People's Republic of China
| | - Ahmed Abass
- School of Engineering, University of Liverpool, Liverpool, UK
- Department of Production Engineering and Mechanical Design, Faculty of Engineering, Port Said University, Port Fuad, Egypt
| | - Ahmed Elsheikh
- School of Engineering, University of Liverpool, Liverpool, UK
- Beijing Advanced Innovation Centre for Biomedical Engineering, Beihang University, Beijing, People's Republic of China
- National Institute for Health Research (NIHR) Biomedical Research Centre at Moorfields Eye Hospital NHS Foundation Trust and UCL Institute of Ophthalmology, London, UK
| |
Collapse
|
26
|
Wu J, Fang W, Xu H, Liu X, Zhao D, Rong Q. The Biomechanical Response of the Cornea in Orthokeratology. Front Bioeng Biotechnol 2021; 9:743745. [PMID: 34708026 PMCID: PMC8542762 DOI: 10.3389/fbioe.2021.743745] [Citation(s) in RCA: 10] [Impact Index Per Article: 3.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/19/2021] [Accepted: 09/06/2021] [Indexed: 11/13/2022] Open
Abstract
Orthokeratology has been widely used to control myopia, but the mechanism is still unknown. To further investigate the underlying mechanism of corneal reshaping using orthokeratology lenses via the finite element method, numerical models with different corneal curvatures, corneal thicknesses, and myopia reduction degrees had been developed and validated to simulate the corneal response and quantify the changes in maximum stress in the central and peripheral corneal areas during orthokeratology. The influence of the factors on corneal response had been analyzed by using median quantile regression. A partial eta squared value in analysis of variance models was established to compare the effect size of these factors. The results showed central and peripheral corneal stress responses changed significantly with increased myopia reduction, corneal curvature, and corneal thickness. The target myopia reduction had the greatest effect on the central corneal stress value (partial eta square = 0.9382), followed by corneal curvature (partial eta square = 0.5650) and corneal thickness (partial eta square = 0.1975). The corneal curvature had the greatest effect on the peripheral corneal stress value (partial eta square = 0.5220), followed by myopia reduction (partial eta square = 0.2375) and corneal thickness (partial eta square = 0.1972). In summary, the biomechanical response of the cornea varies significantly with the change in corneal conditions and lens designs. Therefore, the orthokeratology lens design and the lens fitting process should be taken into consideration in clinical practice, especially for patients with high myopia and steep corneas.
Collapse
Affiliation(s)
- Jinfang Wu
- Department of Mechanics and Engineering Science, College of Engineering, Peking University, Beijing, China
| | - Wenxuan Fang
- Department of Mechanics and Engineering Science, College of Engineering, Peking University, Beijing, China
| | - Huiwen Xu
- Department of Epidemiology and Biostatistics, School of Public Health, Peking University, Beijing, China.,Medical Informatics Center, Peking University, Beijing, China
| | - Xiaode Liu
- Department of Mechanics and Engineering Science, College of Engineering, Peking University, Beijing, China.,X Lab, the Second Academy of CASIC, Beijing, China
| | - Dongliang Zhao
- School of Chemical Biology and Biotechnology, Peking University Shenzhen Graduate School, Shenzhen, China
| | - Qiguo Rong
- Department of Mechanics and Engineering Science, College of Engineering, Peking University, Beijing, China
| |
Collapse
|
27
|
Hoshing AA, Bhosale S, Samant MP, Bamne A, Kalyankar H. A cross-sectional study to determine the normal corneal epithelial thickness in Indian population using 9-mm wide optical coherence tomography scans. Indian J Ophthalmol 2021; 69:2425-2429. [PMID: 34427236 PMCID: PMC8544085 DOI: 10.4103/ijo.ijo_244_21] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/04/2022] Open
Abstract
Purpose To study the corneal epithelial thickness with 9-mm scans of optical coherence tomography in normal Indians with appropriate representation of all age groups. Methods This was a cross-sectional observational study. 263 patients were divided into the age groups 5-20 years, 21-35 years, 36-50 years and more than 51 years were recruited for the study. All patients underwent a detailed ophthalmic examination. Patients found to have any ocular surface or intraocular disease condition (except cataract and refractive error), or who had undergone any ophthalmic surgery in the past, or had corneal topography changes suggestive of corneal ectasias (screened in patients with astigmatism more than 3 diopters) or had been continuously using any topical medication in either eye for a period of 3 months or more with the last instillation being within 1 month of inclusion in the study were excluded. All subjects underwent corneal epithelial thickness measurement with anterior segment optical coherence tomography (AS-OCT) on the Avanti OCT (Model RTVueXR1002, Optovue, USA). The corneal epithelial thickness (CET) data from 25 sectors in each eye were analyzed. Results 263 right and left eyes of 263 patients were analyzed in the study. Mean CETs in the central 2 mm zone were 54.13 ± 4.51 μm and 54.37 ± 3.75 μm for the right and left eyes, respectively. The superior peripheral sectors and inferior paracentral sectors were the thinnest and the thickest sectors, respectively, in both eyes. Conclusion CET parameters for Indian eyes are comparable to those reported from racially distinct and geographically distant study subjects.
Collapse
Affiliation(s)
- Abhishek A Hoshing
- Department of Cornea and Refractive Surgery, Strabismus and Neuro-Ophthalmology, Laxmi Eye Institute, Panvel; Department of Ophthalmology, Apollo Hospitals, Navi Mumbai, Maharashtra, India
| | - Seema Bhosale
- Department of Cataract Services, Strabismus and Neuro-Ophthalmology, Laxmi Eye Institute, Panvel, Maharashtra, India
| | - Monica P Samant
- Department of Pediatric Ophthalmology, Strabismus and Neuro-Ophthalmology, Laxmi Eye Institute, Panvel, Maharashtra, India
| | - Aditya Bamne
- Department of Clinical Optometry, Laxmi Eye Institute, Panvel, Maharashtra, India
| | - Huma Kalyankar
- Department of Clinical Optometry, Laxmi Eye Institute, Panvel, Maharashtra, India
| |
Collapse
|
28
|
Nam M, Kim SW. Changes in Corneal Epithelial Thickness Induced by Topical Antiglaucoma Medications. J Clin Med 2021; 10:jcm10163464. [PMID: 34441760 PMCID: PMC8397015 DOI: 10.3390/jcm10163464] [Citation(s) in RCA: 8] [Impact Index Per Article: 2.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/11/2021] [Revised: 07/30/2021] [Accepted: 08/02/2021] [Indexed: 12/20/2022] Open
Abstract
Corneal thickness measurement is important for assessing intraocular pressure in patients with glaucoma. This study investigated the changes in corneal epithelial thickness (CET) induced by antiglaucoma medications and explored the factors affecting CET measurement. CET was measured over a 9.0 mm diameter area by using Fourier domain optical coherence tomography in 125 patients with primary open-angle glaucoma and 125 age-matched controls without glaucoma. The influence of sex, age, benzalkonium chloride (BAK)-containing instillations, disease severity, and types and numbers of medications was analyzed using simple and multiple regression analyses. CET over 25 sectors was smaller in the glaucoma group than in the control group (mean difference of 4.2 µm in the central 2.0 mm zone; 52.8 ± 3.6 vs. 48.5 ± 3.9, p < 0.001). Simple regression analysis revealed age, use of β-blockers, prostaglandin, carbonic anhydrase inhibitors, total number of medications, and number of daily BAK-containing instillations were associated with a thinner epithelium. Multiple regression analysis revealed β-blockers, prostaglandin, and number of BAK-containing instillations were significant factors. Use of β-blockers and number of BAK-containing instillations were also associated with a thinner epithelium in the monotherapy subgroup analysis. CET was significantly smaller in patients with glaucoma receiving topical medications and was affected by the use of β-blockers, prostaglandin, and BAK.
Collapse
|
29
|
Wan K, Yau HT, Cheung SW, Cho P. Corneal thickness changes in myopic children during and after short-term orthokeratology lens wear. Ophthalmic Physiol Opt 2021; 41:757-767. [PMID: 33878198 DOI: 10.1111/opo.12824] [Citation(s) in RCA: 11] [Impact Index Per Article: 3.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/29/2020] [Accepted: 02/08/2021] [Indexed: 01/02/2023]
Abstract
PURPOSE To evaluate thickness changes in the central and mid-peripheral cornea (CCT and mPCT), corneal epithelium (CET and mPET) and stroma (CST and mPST) of myopic children during and after short-term orthokeratology (ortho-k) lens wear, with conventional (CCF, 0.75 D) and increased compression factors (ICF, 1.75 D). METHODS This was a self-controlled case series study. Subjects wore a CCF lens in one eye and an ICF lens in the other. Anterior segment optical coherence tomography images were captured weekly for 1 month during lens wear and for 2 weeks after discontinuing lens wear. CCT and CET (central 3-mm cornea) and mPCT and mPET (within a 4-6 mm diameter annulus) were measured. Stromal thickness (ST) was determined by subtracting epithelium thickness (ET) from corneal thickness (CT). The repeatability of the analytical software was also investigated on age-matched spectacle-wearing subjects (n = 98). RESULTS Excluding three outliers (>3 S.D.s), the coefficient of repeatability and intraclass correlation coefficients of 98 spectacle-wearing subjects ranged from 2.63 to 4.64 μm and from 0.90 to 0.99, respectively. For the weekly-change study, CCT and CET in both eyes were significantly thinner after lens wear (p < 0.001) and CET thinning in the ICF eyes were significantly higher (p < 0.02). CCT changes were mainly contributed by CET. CST, mPCT, mPET and mPST changes were not significant (p > 0.20) in either eye. CT (all sublayers) rebounded to baseline values 2 weeks after discontinuing lens wear (0.99 > p > 0.12). CONCLUSIONS Significant reductions in CT and ET, but not ST, were observed within 1 month of ortho-k lens wear. Wearing ICF lenses resulted in a higher reduction in CET. Corneal thickness changes were reversible after discontinuing lens wear.
Collapse
Affiliation(s)
- Kin Wan
- Centre for Myopia Research, School of Optometry, The Hong Kong Polytechnic University, Hong Kong Special Administrative Region, China
| | - Hing Tuen Yau
- Information Technology Services, The University of Hong Kong, Hong Kong Special Administrative Region, China
| | - Sin Wan Cheung
- Centre for Myopia Research, School of Optometry, The Hong Kong Polytechnic University, Hong Kong Special Administrative Region, China
| | - Pauline Cho
- Centre for Myopia Research, School of Optometry, The Hong Kong Polytechnic University, Hong Kong Special Administrative Region, China
| |
Collapse
|
30
|
Nti AN, Berntsen DA. Optical changes and visual performance with orthokeratology. Clin Exp Optom 2021; 103:44-54. [DOI: 10.1111/cxo.12947] [Citation(s) in RCA: 16] [Impact Index Per Article: 5.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/02/2019] [Revised: 06/17/2019] [Accepted: 06/18/2019] [Indexed: 12/24/2022] Open
Affiliation(s)
- Augustine N Nti
- The Ocular Surface Institute, College of Optometry, University of Houston, Houston, Texas, USA,
| | - David A Berntsen
- The Ocular Surface Institute, College of Optometry, University of Houston, Houston, Texas, USA,
| |
Collapse
|
31
|
Kim WK, Ryu IH, Yoo J, Kim SW. Effect of Gender, Age, and Ocular and Growth-Related Factors on Corneal Epithelial and Stromal Thickness in Children. J Clin Med 2020; 9:jcm9123849. [PMID: 33260816 PMCID: PMC7760657 DOI: 10.3390/jcm9123849] [Citation(s) in RCA: 7] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/28/2020] [Revised: 11/24/2020] [Accepted: 11/25/2020] [Indexed: 01/01/2023] Open
Abstract
Data on corneal epithelial and stromal thickness in school-aged children in relation to gender, age, and ocular and growth parameters are limited. In this retrospective study, we analyzed corneal epithelial and stromal thickness measured with the RTVue system (Optovue, Inc., Fremont, CA, USA) in 122 male and 201 female Korean children (mean age 9.59 ± 2.18 years) with myopia. We used simple and multiple regression analysis to establish the relationships between gender, age, refractive status, axial length, anterior chamber depth (ACD), corneal refractive power, white-to-white corneal diameter (WTW), height, and body weight. Age, body weight, height, and central corneal thickness were positively associated with corneal epithelial thickness, whereas WTW was negatively associated. The multiple regression analysis showed corneal epithelial thickness was affected by sex, body weight, WTW, and central corneal thickness (CCT), while stromal thickness was influenced by age, sex, and WTW. Both corneal epithelial and stromal thickness were significantly greater in male than in female children and were affected by growth. Neither corneal epithelial nor stromal thickness were associated with the severity of myopia, corneal refractive power, or axial length.
Collapse
Affiliation(s)
- Wook Kyum Kim
- B & VIIT Eye Center, Seoul 06615, Korea; (W.K.K.); (I.H.R.)
| | - Ik Hee Ryu
- B & VIIT Eye Center, Seoul 06615, Korea; (W.K.K.); (I.H.R.)
| | - Jeongseo Yoo
- Department of Ophthalmology, Yonsei University Wonju College of Medicine, Wonju 26426, Gangwon-do, Korea;
| | - Sun Woong Kim
- Department of Ophthalmology, Yonsei University Wonju College of Medicine, Wonju 26426, Gangwon-do, Korea;
- Correspondence:
| |
Collapse
|
32
|
Lin Z, Duarte-Toledo R, Manzanera S, Lan W, Artal P, Yang Z. Two-dimensional peripheral refraction and retinal image quality in orthokeratology lens wearers. BIOMEDICAL OPTICS EXPRESS 2020; 11:3523-3533. [PMID: 33014548 PMCID: PMC7510915 DOI: 10.1364/boe.397077] [Citation(s) in RCA: 6] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Received: 05/07/2020] [Revised: 05/26/2020] [Accepted: 05/26/2020] [Indexed: 05/28/2023]
Abstract
Orthokeratology (O-K) is a common procedure that uses rigid contact lenses to reshape the cornea while worn overnight. Beyond the correction of refractive error, it has been suggested that this approach can also be used to reduce myopia progression, possibly because it induces changes in peripheral optics. As this hypothesis remains unproven, the aim of the present study was to explore changes in peripheral retinal optical quality in a group of myopic children following O-K treatment. We provide a comprehensive description of optical characteristics in a group of myopes before and after achieving stable corneal reshaping using overnight O-K lenses. These characteristics extended across the central visual field (60° horizontal x 36° vertical) as measured with a custom Hartmman-Shack wavefront sensor. After corneal reshaping, peripheral refraction was found to be asymmetrically distributed, with a myopic relative refraction of approximately 3D in the temporal retina. Astigmatism and higher order aberrations also increased in the temporal side. Based on corneal topography following treatment, subjects were divided into two groups: Centred Treatment (CT, decentration ∈ [-0.5 + 0.5] mm) and Slightly Decentred Treatment (subjects with more decentred lenses). The process was also modelled by ray-tracing simulation. The results indicate that increased myopia in the temporal retina is caused by the decentration of lenses towards the temporal side. Peripheral optics differ significantly following O-K lens treatment, but further research is required to determine whether this is likely to affect myopia progression.
Collapse
Affiliation(s)
- Zhenghua Lin
- Aier School of Ophthalmology, Central South University, Changsha, China
| | - Raul Duarte-Toledo
- Laboratorio de Óptica, Universidad de Murcia, Campus de Espinardo, 30100, Murcia, Spain
| | - Silvestre Manzanera
- Laboratorio de Óptica, Universidad de Murcia, Campus de Espinardo, 30100, Murcia, Spain
| | - Weizhong Lan
- Aier School of Ophthalmology, Central South University, Changsha, China
- Aier School of Optometry, Hubei University of Science and Technology, Xianning, China
| | - Pablo Artal
- Laboratorio de Óptica, Universidad de Murcia, Campus de Espinardo, 30100, Murcia, Spain
- Aier School of Ophthalmology, Central South University, Changsha, China
| | - Zhikuan Yang
- Aier School of Ophthalmology, Central South University, Changsha, China
- Aier School of Optometry, Hubei University of Science and Technology, Xianning, China
| |
Collapse
|
33
|
Corneal Total and Epithelial Thickness Measured by Sonogage Ultrasound Pachometry and High-resolution Optical Coherence Tomography. Optom Vis Sci 2020; 97:346-350. [PMID: 32413006 DOI: 10.1097/opx.0000000000001508] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/26/2022] Open
Abstract
SIGNIFICANCE This research questions the validity of using the Sonogage ultrasound (US) pachometer to measure corneal epithelial thickness and coincidentally provides confirmation for the conventional view of the mechanism of orthokeratology (OK) based on central epithelial thinning. PURPOSE The Sonogage (Corneo-Gage Plus 1) pachometer uses A-scan US to measure total corneal thickness. It is claimed that this instrument can also measure corneal epithelial thickness. We sought to validate this claim by comparing total and epithelial thickness measurements with the Sonogage with those obtained with high-resolution optical coherence tomography (OCT). METHODS Fourteen non-contact lens wearers and 14 subjects who had worn Paragon CRT OK lenses overnight for greater than 1 month were recruited. Three OCT and five US measurements were taken in one eye of each subject. Depending on normality of data, paired t tests or Wilcoxon tests were used to compare total and epithelial thicknesses measured with the Sonogage pachometer and the Tomey Casia OCT. Pearson or Spearman correlation analyses were used to examine relationships between measurements obtained with the two instruments. RESULTS There was a significant difference in total corneal thickness measurements between the two instruments. Although a significant correlation was found (r = 0.916, P < .001), the Sonogage consistently measured greater total corneal thickness than did the OCT (+19.5 ± 9.2 μm; P < .001). Epithelial thickness using the Sonogage showed little variation (range, 46.4 to 50.0 μm), whereas epithelial thickness using the OCT ranged from 30.7 to 54.7 μm. There was no significant correlation between epithelial thicknesses obtained with the two instruments (r = -0.135, P = .49). Epithelial thickness measured by OCT was significantly thinner in OK wearers (35.8 ± 2.8 μm) than in nonlens wearers (46.7 ± 4.5 μm, P < .001). CONCLUSIONS The Sonogage is not able to measure epithelial thickness in vivo, returning essentially identical measurements over a range of epithelial thicknesses. Optical coherence tomography measurements confirm the conventional view of the mechanism of OK based on central epithelial thinning.
Collapse
|
34
|
Correlation of corneal pigmented arc with wide epithelial thickness map in orthokeratology-treated children using optical coherence tomography measurements. Cont Lens Anterior Eye 2020; 43:238-243. [PMID: 32143962 DOI: 10.1016/j.clae.2020.02.004] [Citation(s) in RCA: 7] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/20/2019] [Revised: 12/25/2019] [Accepted: 02/12/2020] [Indexed: 11/24/2022]
Abstract
PURPOSE To determine the intensity of corneal pigmented arc in orthokeratology (ortho-k)-treated children and its correlation with wide epithelial thickness map (ETM) obtained through anterior segment optical coherent tomography (AS-OCT). METHODS This retrospective case series reviews medical records of children who received ortho-k treatment for myopia control. Intensity of ortho-k-associated pigmented arc after wearing ortho-k lens more than 12 months and its correlation with each sector/zone of wide ETM obtained by AS-OCT was explored. Pigmented arcs were further divided into apparent and unapparent groups, and the clinical differences between groups were determined. RESULTS This study included 57 eyes of 29 children (mean age, 11.4 years, range 9-15); after initiating ortho-k treatment, the incidence of the corneal pigmented arc was 91.2% with mean lens wear duration of 26.1 months. Intensity of pigmented arc was significantly correlated with lens wear duration, target power, baseline degree of myopia, C zone and sectors I2, I3 and IT3 on wide ETM. Comparison between apparent and unapparent groups showed the same significant results except for C zone. After adjusting for lens wear duration and target power, sector I2 has the highest association with pigmented arc severity. CONCLUSION Children treated with ortho-k are likely to develop ortho-k-associated pigmented arcs. The new wide ETM of AS-OCT can provide important information regarding the intensity of pigmented arc in these children. This can support customized pigmented arc-free ortho-k treatment for children in the future.
Collapse
|
35
|
Liu CF, Lee JS, Sun CC, Lin KK, Hou CH, Yeung L, Peng SY. Correlation between pigmented arc and epithelial thickness (COPE) study in orthokeratology-treated patients using OCT measurements. Eye (Lond) 2019; 34:352-359. [PMID: 31391544 DOI: 10.1038/s41433-019-0542-8] [Citation(s) in RCA: 9] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/15/2018] [Revised: 06/23/2019] [Accepted: 07/12/2019] [Indexed: 11/09/2022] Open
Abstract
PURPOSE To determine the intensity of corneal pigmented arc in orthokeratology (ortho-k)-treated children, and its correlation with key epithelial thickness measurements obtained by anterior segment optical coherence tomography (AS-OCT). METHODS This study is a retrospective case series. Medical records of children who received ortho-k treatment for myopia control in our hospital were reviewed. Intensity of ortho-k-associated pigmented arc and its correlation with key epithelial thickness parameters in the central 7-mm-diameter zone obtained by AS-OCT was examined. The subjects were further divided into apparent and unapparent pigmented arc groups for severity comparison. RESULTS The mean age of children was 11.4 years, and the incidence of corneal pigmented arc was 92.2% after lens wear for a mean duration of 21.2 months. Intensity of pigmented arc was found to be significantly correlated with key epithelial thickness parameters, including maximum and minimum epithelial thickness (Spearman's rank correlation coefficient (rs) = 0.404, P = 0.003; rs = - 0.426, P = 0.002, respectively), the difference between them (Min-Max) (rs = -0.624, P < 0.001) and standard deviation (rs = 0.659, P < 0.001). Significant correlation between intensity of pigmented arc and ortho-k target power (rs = 0.454, P = 0.001) was found. Comparison between the two groups showed significant difference in the same key epithelial thickness parameters. CONCLUSIONS Children receiving ortho-k treatment tended to develop pigmented arcs. Significant correlation between intensity of pigmented arc and key epithelial thickness parameters was observed. AS-OCT can be a useful tool for predicting intensity of pigmented arc in ortho-k-treated children.
Collapse
Affiliation(s)
- Chun-Fu Liu
- Department of Ophthalmology, Chang Gung Memorial Hospital, Keelung, Taiwan.,College of Medicine, Chang Gung University, Taoyuan, Taiwan.,Program in Molecular Medicine, National Yang Ming University, Taipei, Taiwan
| | - Jiahn-Shing Lee
- College of Medicine, Chang Gung University, Taoyuan, Taiwan.,Department of Ophthalmology, Chang Gung Memorial Hospital, Linkou, Taiwan
| | - Chi-Chin Sun
- Department of Ophthalmology, Chang Gung Memorial Hospital, Keelung, Taiwan.,Department of Chinese Medicine, College of Medicine, Chang Gung University, Taoyuan, Taiwan
| | - Ken-Kuo Lin
- College of Medicine, Chang Gung University, Taoyuan, Taiwan.,Department of Ophthalmology, Chang Gung Memorial Hospital, Linkou, Taiwan
| | - Chiun-Ho Hou
- College of Medicine, Chang Gung University, Taoyuan, Taiwan.,Department of Ophthalmology, Chang Gung Memorial Hospital, Linkou, Taiwan
| | - Ling Yeung
- Department of Ophthalmology, Chang Gung Memorial Hospital, Keelung, Taiwan.,College of Medicine, Chang Gung University, Taoyuan, Taiwan
| | - Shu-Yen Peng
- Department of Ophthalmology, Chang Gung Memorial Hospital, Keelung, Taiwan. .,College of Medicine, Chang Gung University, Taoyuan, Taiwan.
| |
Collapse
|