1
|
Colautti A, Civilini M, Bortolomeazzi R, Franchi M, Felice A, De Martin S, Iacumin L. Genotypic and phenotypic profiling of 127 Legionella pneumophila strains: Insights into regional spread. PLoS One 2024; 19:e0307646. [PMID: 39028750 PMCID: PMC11259292 DOI: 10.1371/journal.pone.0307646] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/15/2024] [Accepted: 07/10/2024] [Indexed: 07/21/2024] Open
Abstract
Given the recent global surge in Legionnaires' disease cases, the monitoring of Legionella pneumophila becomes increasingly crucial. Epidemiological cases often stem from local outbreaks rather than widespread dissemination, emphasizing the need to study the characteristics of this pathogen at a local level. This study focuses on isolates of L. pneumophila in the Italian region of Friuli Venezia Giulia to assess specific genotype and phenotype distribution over time and space. To this end, a total of 127 L. pneumophila strains isolated between 2005 and 2017 within national surveillance programs were analysed. Rep-PCR, RAPD, and Sau-PCR were used for genotypic characterization, while phenotypic characterization was conducted through fatty acids analysis. RAPD and Sau-PCR effectively assessed genetic characteristics, identifying different profiles for the isolates and excluding the presence of clones. Although Sau-PCR is rarely used to analyse this pathogen, it emerged as the most discriminatory technique. Phenotypically, hierarchical cluster analysis categorized strains into three groups based on varying membrane fatty acid percentages. However, both phenotypic and genotypic analyses revealed a ubiquitous profile distribution at a regional level. These results suggest an absence of correlations between strain profiles, geographical location, and isolation time, indicating instead high variability and strain dissemination within this region.
Collapse
Affiliation(s)
- Andrea Colautti
- Department of Agricultural, Food, Environmental and Animal Science (Di4A), University of Udine, Udine, Italy
| | - Marcello Civilini
- Department of Agricultural, Food, Environmental and Animal Science (Di4A), University of Udine, Udine, Italy
| | - Renzo Bortolomeazzi
- Department of Agricultural, Food, Environmental and Animal Science (Di4A), University of Udine, Udine, Italy
| | - Marinella Franchi
- Laboratory of Microbiology, ARPA–Regional Agency for Environmental Protection Friuli Venezia Giulia, Udine, Italy
| | - Antonella Felice
- Laboratory of Microbiology, ARPA–Regional Agency for Environmental Protection Friuli Venezia Giulia, Udine, Italy
| | - Stefano De Martin
- Laboratory of Microbiology, ARPA–Regional Agency for Environmental Protection Friuli Venezia Giulia, Udine, Italy
| | - Lucilla Iacumin
- Department of Agricultural, Food, Environmental and Animal Science (Di4A), University of Udine, Udine, Italy
| |
Collapse
|
2
|
Riccò M, Ferraro P, Ranzieri S, Boldini G, Zanella I, Marchesi F. Legionnaires' Disease in Occupational Settings: A Cross-Sectional Study from Northeastern Italy (2019). Trop Med Infect Dis 2023; 8:364. [PMID: 37505660 PMCID: PMC10384770 DOI: 10.3390/tropicalmed8070364] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/12/2023] [Revised: 07/09/2023] [Accepted: 07/15/2023] [Indexed: 07/29/2023] Open
Abstract
In Italy, Legionnaires' Disease (LD) causes >1000 hospital admissions per year, with a lethality rate of 5 to 10%. Occupational exposures could reasonably explain a substantial share of total cases, but the role of Occupational Physicians (OPs) in management and prevention of LD has been scarcely investigated. The present survey therefore evaluates the knowledge, attitudes and practices (KAP) regarding LD from a convenience sample of Italian OPs, focusing on their participation in preventive interventions. A total of 165 OPs were recruited through a training event (Parma, Northeastern Italy, 2019), and completed a specifically designed structured questionnaire. The association between reported participation in preventive interventions and individual factors was analyzed using a binary logistic regression model, calculating corresponding multivariable Odds Ratio (aOR). Overall, participants exhibited satisfactory knowledge of the clinical and diagnostic aspects of LD, while substantial uncertainties were associated epidemiological factors (i.e., notification rate and lethality). Although the majority of participating OPs reportedly assisted at least one hospital (26.7%) and/or a nursing home (42.4%) and/or a wastewater treatment plant, only 41.8% reportedly contributed to the risk assessment for LD and 18.8% promoted specifically designed preventive measures. Working as OPs in nursing homes (aOR 8.732; 95% Confidence Intervals [95%CI] 2.991 to 25.487) and wastewater treatment plants (aOR 8.710; 95%CI 2.844 to 26.668) was associated with participation in the risk assessment for LD, while the promotion of preventive practice was associated with working as an OP in hospitals (aOR 6.792; 95%CI 2.026 to 22.764) and wastewater treatment plants (aOR 4.464, 95%CI 1.363 to 14.619). In other words, the effective participation of the OP in the implementation of preventive measures appears uncommon and is limited to certain occupational settings. Collectively, these results highlight the importance of tailoring specifically designed information campaigns aimed to raise the involvement of OPs in the prevention of LD in occupational settings other than healthcare.
Collapse
Affiliation(s)
- Matteo Riccò
- Servizio di Prevenzione e Sicurezza Negli Ambienti di Lavoro (SPSAL), AUSL-IRCCS di Reggio Emilia, Via Amendola n.2, I-42122 Reggio Emilia, Italy
| | - Pietro Ferraro
- Occupational Medicine Unit, Direzione Sanità, Italian Railways' Infrastructure Division, RFI SpA, I-00161 Rome, Italy
| | - Silvia Ranzieri
- Department of Medicine and Surgery, University of Parma, Via Gramsci, 14, I-43126 Parma, Italy
| | - Giorgia Boldini
- Department of Medicine and Surgery, University of Parma, Via Gramsci, 14, I-43126 Parma, Italy
- Servizio di Igiene Pubblica, AUSL di Parma, Via Vasari n.13/a, I-43123 Parma, Italy
| | - Ilaria Zanella
- Department of Medicine and Surgery, University of Parma, Via Gramsci, 14, I-43126 Parma, Italy
| | - Federico Marchesi
- Department of Medicine and Surgery, University of Parma, Via Gramsci, 14, I-43126 Parma, Italy
| |
Collapse
|
3
|
Valciņa O, Pūle D, Ķibilds J, Labecka L, Terentjeva M, Krūmiņa A, Bērziņš A. Evaluation of Genetic Diversity and Virulence Potential of Legionella pneumophila Isolated from Water Supply Systems of Residential Buildings in Latvia. Pathogens 2023; 12:884. [PMID: 37513731 PMCID: PMC10385952 DOI: 10.3390/pathogens12070884] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/27/2023] [Revised: 06/21/2023] [Accepted: 06/27/2023] [Indexed: 07/30/2023] Open
Abstract
Legionella is an opportunistic pathogen with a biphasic life cycle that occasionally infects humans. The aim of the study was to assess the distribution of virulence genes and genetic diversity among L. pneumophila isolated from water supply systems of residential buildings in Latvia. In total, 492 water samples from 200 residential buildings were collected. Identification of Legionella spp. was performed according to ISO 11731, and 58 isolates were subjected to whole-genome sequencing. At least one Legionella-positive sample was found in 112 out of 200 apartment buildings (56.0%). The study revealed extensive sequence-type diversity, where 58 L. pneumophila isolates fell into 36 different sequence types. A total of 420 virulence genes were identified, of which 260 genes were found in all sequenced L. pneumophila isolates. The virulence genes enhC, htpB, omp28, and mip were detected in all isolates, suggesting that adhesion, attachment, and entry into host cells are enabled for all isolates. The relative frequency of virulence genes among L. pneumophila isolates was high. The high prevalence, extensive genetic diversity, and the wide range of virulence genes indicated that the virulence potential of environmental Legionella is high, and proper risk management is of key importance to public health.
Collapse
Affiliation(s)
- Olga Valciņa
- Institute of Food Safety, Animal Health and Environment "BIOR", LV-1076 Riga, Latvia
| | - Daina Pūle
- Institute of Food Safety, Animal Health and Environment "BIOR", LV-1076 Riga, Latvia
- Department of Water Engineering and Technology, Riga Technical University, LV-1048 Riga, Latvia
| | - Juris Ķibilds
- Institute of Food Safety, Animal Health and Environment "BIOR", LV-1076 Riga, Latvia
| | - Linda Labecka
- Institute of Food Safety, Animal Health and Environment "BIOR", LV-1076 Riga, Latvia
| | - Margarita Terentjeva
- Institute of Food and Environmental Hygiene, Faculty of Veterinary Medicine, Latvia University of Life Sciences and Technologies, LV-3004 Jelgava, Latvia
| | - Angelika Krūmiņa
- Department of Infectology, Riga Stradiņš University, LV-1007 Riga, Latvia
| | - Aivars Bērziņš
- Institute of Food Safety, Animal Health and Environment "BIOR", LV-1076 Riga, Latvia
| |
Collapse
|
4
|
Lombardi A, Borriello T, De Rosa E, Di Duca F, Sorrentino M, Torre I, Montuori P, Trama U, Pennino F. Environmental Monitoring of Legionella in Hospitals in the Campania Region: A 5-Year Study. INTERNATIONAL JOURNAL OF ENVIRONMENTAL RESEARCH AND PUBLIC HEALTH 2023; 20:ijerph20085526. [PMID: 37107807 PMCID: PMC10138562 DOI: 10.3390/ijerph20085526] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 03/06/2023] [Revised: 04/06/2023] [Accepted: 04/13/2023] [Indexed: 05/11/2023]
Abstract
Legionella is a pathogen that colonizes soils, freshwater, and building water systems. People who are most affected are those with immunodeficiencies, so it is necessary to monitor its presence in hospitals. The purpose of this study was to evaluate the presence of Legionella in water samples collected from hospitals in the Campania region, Southern Italy. A total of 3365 water samples were collected from January 2018 to December 2022 twice a year in hospital wards from taps and showers, tank bottoms, and air-treatment units. Microbiological analysis was conducted in accordance with the UNI EN ISO 11731:2017, and the correlations between the presence of Legionella and water temperature and residual chlorine were investigated. In total, 708 samples (21.0%) tested positive. The most represented species was L. pneumophila 2-14 (70.9%). The serogroups isolated were 1 (27.7%), 6 (24.5%), 8 (23.3%), 3 (18.9%), 5 (3.1%), and 10 (1.1%). Non-pneumophila Legionella spp. represented 1.4% of the total. Regarding temperature, the majority of Legionella positive samples were found in the temperature range of 26.0-40.9 °C. An influence of residual chlorine on the presence of the bacterium was observed, confirming that chlorine disinfection is effective for controlling contamination. The positivity for serogroups other than serogroup 1 suggested the need to continue environmental monitoring of Legionella and to focus on the clinical diagnosis of other serogroups.
Collapse
Affiliation(s)
- Annalisa Lombardi
- Department of Public Health, University “Federico II”, Via Sergio Pansini N° 5, 80131 Naples, Italy
| | - Tonia Borriello
- Department of Public Health, University “Federico II”, Via Sergio Pansini N° 5, 80131 Naples, Italy
| | - Elvira De Rosa
- Department of Public Health, University “Federico II”, Via Sergio Pansini N° 5, 80131 Naples, Italy
| | - Fabiana Di Duca
- Department of Public Health, University “Federico II”, Via Sergio Pansini N° 5, 80131 Naples, Italy
| | - Michele Sorrentino
- Department of Public Health, University “Federico II”, Via Sergio Pansini N° 5, 80131 Naples, Italy
| | - Ida Torre
- Department of Public Health, University “Federico II”, Via Sergio Pansini N° 5, 80131 Naples, Italy
| | - Paolo Montuori
- Department of Public Health, University “Federico II”, Via Sergio Pansini N° 5, 80131 Naples, Italy
| | - Ugo Trama
- General Directorate of Health, Campania Region, Centro Direzionale C3, 80143 Naples, Italy
| | - Francesca Pennino
- Department of Public Health, University “Federico II”, Via Sergio Pansini N° 5, 80131 Naples, Italy
- Correspondence:
| |
Collapse
|
5
|
Gamage SD, Jinadatha C, Coppin JD, Kralovic SM, Bender A, Ambrose M, Decker BK, DeVries AS, Goto M, Kowalskyj O, Maistros AL, Rizzo V, Simbartl LA, Watson RJ, Roselle GA. Factors That Affect Legionella Positivity in Healthcare Building Water Systems from a Large, National Environmental Surveillance Initiative. ENVIRONMENTAL SCIENCE & TECHNOLOGY 2022; 56:11363-11373. [PMID: 35929739 DOI: 10.1021/acs.est.2c02194] [Citation(s) in RCA: 6] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/15/2023]
Abstract
Legionella growth in healthcare building water systems can result in legionellosis, making water management programs (WMPs) important for patient safety. However, knowledge is limited on Legionella prevalence in healthcare buildings. A dataset of quarterly water testing in Veterans Health Administration (VHA) healthcare buildings was used to examine national environmental Legionella prevalence from 2015 to 2018. Bayesian hierarchical logistic regression modeling assessed factors influencing Legionella positivity. The master dataset included 201,146 water samples from 814 buildings at 168 VHA campuses. Overall Legionella positivity over the 4 years decreased from 7.2 to 5.1%, with the odds of a Legionella-positive sample being 0.94 (0.90-0.97) times the odds of a positive sample in the previous quarter for the 16 quarters of the 4 year period. Positivity varied considerably more at the medical center campus level compared to regional levels or to the building level where controls are typically applied. We found higher odds of Legionella detection in older buildings (OR 0.92 [0.86-0.98] for each more recent decade of construction), in taller buildings (OR 1.20 [1.13-1.27] for each additional floor), in hot water samples (O.R. 1.21 [1.16-1.27]), and in samples with lower residual biocide concentrations. This comprehensive healthcare building review showed reduced Legionella detection in the VHA healthcare system over time. Insights into factors associated with Legionella positivity provide information for healthcare systems implementing WMPs and for organizations setting standards and regulations.
Collapse
Affiliation(s)
- Shantini D Gamage
- National Infectious Diseases Service, Specialty Care Program Office, Veterans Health Administration, Department of Veterans Affairs (VA), Washington, D.C. 20571, United States
- Division of Infectious Diseases, Department of Internal Medicine, University of Cincinnati College of Medicine, Cincinnati, Ohio 45267, United States
| | - Chetan Jinadatha
- Department of Medicine, Central Texas Veterans Health Care System, Temple, Texas 76504, United States
- College of Medicine, Texas A&M University, Bryan, Texas 77807, United States
| | - John D Coppin
- Department of Research, Central Texas Veterans Health Care System, Temple, Texas 76504, United States
| | - Stephen M Kralovic
- National Infectious Diseases Service, Specialty Care Program Office, Veterans Health Administration, Department of Veterans Affairs (VA), Washington, D.C. 20571, United States
- Division of Infectious Diseases, Department of Internal Medicine, University of Cincinnati College of Medicine, Cincinnati, Ohio 45267, United States
- Cincinnati VA Medical Center, Cincinnati, Ohio 45220, United States
| | - Alan Bender
- Booz Allen Hamilton, McLean, Virginia 22102, United States
| | - Meredith Ambrose
- National Infectious Diseases Service, Specialty Care Program Office, Veterans Health Administration, Department of Veterans Affairs (VA), Washington, D.C. 20571, United States
| | - Brooke K Decker
- Division of Infectious Diseases, VA Pittsburgh Healthcare System, Pittsburgh, Pennsylvania 15240, United States
| | - Aaron S DeVries
- Minneapolis VA Healthcare System, Minneapolis, Minnesota 55417, United States
| | - Michihiko Goto
- Iowa City VA Health Care System, Iowa City, Iowa 52246, United States
- University of Iowa Carver College of Medicine, Iowa City, Iowa 52242, United States
| | - Oleh Kowalskyj
- Office of Healthcare Engineering, Healthcare Environment and Facilities Program, Veterans Health Administration, VA, Washington, D.C. 20571, United States
| | - Angela L Maistros
- VA Capitol Health Care Network, Veterans Integrated Service Network (VISN) 5, Linthicum, Maryland 21090, United States
| | - Vincent Rizzo
- Office of Healthcare Engineering, Healthcare Environment and Facilities Program, Veterans Health Administration, VA, Washington, D.C. 20571, United States
| | - Loretta A Simbartl
- National Infectious Diseases Service, Specialty Care Program Office, Veterans Health Administration, Department of Veterans Affairs (VA), Washington, D.C. 20571, United States
| | - Richard J Watson
- Occupational Health and Safety Program Office, Veterans Health Administration, VA, Washington, D.C. 20571, United States
| | - Gary A Roselle
- National Infectious Diseases Service, Specialty Care Program Office, Veterans Health Administration, Department of Veterans Affairs (VA), Washington, D.C. 20571, United States
- Division of Infectious Diseases, Department of Internal Medicine, University of Cincinnati College of Medicine, Cincinnati, Ohio 45267, United States
- Cincinnati VA Medical Center, Cincinnati, Ohio 45220, United States
| |
Collapse
|
6
|
Doménech-Sánchez A, Laso E, Berrocal CI, Albertí S. Environmental surveillance of Legionella in tourist facilities of the Balearic Islands, Spain, 2006 to 2010 and 2015 to 2018. Euro Surveill 2022; 27:2100769. [PMID: 35621000 PMCID: PMC9137269 DOI: 10.2807/1560-7917.es.2022.27.21.2100769] [Citation(s) in RCA: 4] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/23/2021] [Accepted: 12/20/2021] [Indexed: 06/15/2023] Open
Abstract
BackgroundLegionnaires' disease is a respiratory illness often associated with hotels and travel. Spain is a major tourist destination and one of the European countries with most cases of Legionnaires' disease , both community- and travel-associated. However, the prevalence of Legionella in tourist facilities is unknown.AimThe present investigation aimed to survey the tourist facilities in the Balearic Islands, Spain, for Legionella prevalence.MethodsWe visited tourist facilities in the Balearic Islands in two different periods (2006-2010 and 2015-2018) and took water samples following national and international guidelines. Legionella was investigated by culture methods following international standards (ISO 11731:1998).ResultsWe evaluated 13,472 samples from 465 facilities. Bacteria of the Legionella genus were detected in 65.4% of the surveyed facilities. Contamination of the facilities was significantly higher during the second decade (54.5 vs 78.6%). The most frequent colonisers were L. pneumophila serogroup 2-14. We detected the pathogen in 15.9% and 6.9% of hot and cold water distribution systems samples, respectively. The Legionella contamination rate in cold water systems samples was higher when free chlorine levels were < 0.2 mg/L and at > 25 °C temperatures, while in the hot water systems samples, the contamination rate was higher at < 50 °C. Of the samples from hot tubs, 10.9% were contaminated.ConclusionLegionella prevalence in hotels in the Balearic Islands was high but the contamination rates depended on the installations. Corrective measures are still needed to improve Legionella control.
Collapse
Affiliation(s)
- Antonio Doménech-Sánchez
- Saniconsult Ibérica SL, Palma de Mallorca, Spain
- Instituto Universitario de Investigación en Ciencias de la Salud (IUNICS), Universidad de las Islas Baleares, Palma de Mallorca, Spain
- Instituto de Investigación Sanitaria de les Illes Balears (IdIsBa), Palma de Mallorca, Spain
| | - Elena Laso
- Saniconsult Ibérica SL, Palma de Mallorca, Spain
| | | | - Sebastián Albertí
- Instituto Universitario de Investigación en Ciencias de la Salud (IUNICS), Universidad de las Islas Baleares, Palma de Mallorca, Spain
- Instituto de Investigación Sanitaria de les Illes Balears (IdIsBa), Palma de Mallorca, Spain
| |
Collapse
|
7
|
Doménech-Sánchez A, Laso E, Albertí S. Determination of Legionella spp. prevalence in Spanish hotels in five years. Are tourists really at risk? Travel Med Infect Dis 2022; 46:102269. [DOI: 10.1016/j.tmaid.2022.102269] [Citation(s) in RCA: 2] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/22/2021] [Accepted: 01/26/2022] [Indexed: 11/17/2022]
|
8
|
A Tale of Four Danish Cities: Legionella pneumophila Diversity in Domestic Hot Water and Spatial Variations in Disease Incidence. INTERNATIONAL JOURNAL OF ENVIRONMENTAL RESEARCH AND PUBLIC HEALTH 2022; 19:ijerph19052530. [PMID: 35270223 PMCID: PMC8909801 DOI: 10.3390/ijerph19052530] [Citation(s) in RCA: 2] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 01/24/2022] [Revised: 02/17/2022] [Accepted: 02/18/2022] [Indexed: 01/27/2023]
Abstract
Denmark has one of the highest Legionnaires' disease notification rates within Europe, averaging 4.7 cases per 100,000 population annually (2017 to 2020). The relatively high incidence of disease is not uniform across the country, and approximately 70% of all domestically acquired cases in Denmark are caused by Legionella pneumophila (LP) strains that are considered less virulent. The aim of this study was to investigate if colonization rates, levels of colonization, and/or types of LP present in hot water systems were associated with geographic differences in Legionnaires' disease incidence. Domestic water systems from four cities in Denmark were analyzed via culture and qPCR. Serogrouping and sequence typing was performed on randomly selected isolates. Single nucleotide polymorphism was used to identify clonal relationship among isolates from the four cities. The results revealed a high LP colonization rate from 68% to 87.5% among systems, composed primarily of non-serogroup 1. LP serogroup 1 reacting with the monoclonal antibody (MAb) 3/1 was not identified in any of the systems tested, while MAb 3/1 negative serogroup 1 strains were isolated from 10 systems (9.6%). We hypothesize that a combination of factors influences the incidence rate of LD in each city, including sequence type and serogroup distribution, colonization rate, concentration of Legionella in Pre-flush and Flush samples, and potentially building characteristics such as water temperature measured at the point of use.
Collapse
|
9
|
Riccò M. Impact of lockdown and non-pharmaceutical interventions on the epidemiology of Legionnaires' disease. ACTA BIO-MEDICA : ATENEI PARMENSIS 2022; 93:e2022090. [PMID: 35315385 PMCID: PMC8972893 DOI: 10.23750/abm.v93i1.12744] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 01/02/2022] [Accepted: 01/04/2022] [Indexed: 11/23/2022]
Abstract
BACKGROUND AND AIM In order to cope with the requirements of COVID-19 pandemic and prevent overwhelming of the healthcare systems, during 2020 social distancing measures were proposed, and generalized lockdown. Aim of our study is to ascertain whether non-pharmaceutical intervention did have any impact on the epidemiology of Legionnaires' disease (LD), a respiratory infectious disease without interhuman spreading. METHODS Official national reports from 4 index countries in European Union (i.e. Germany, France, Italy, and Spain) were retrieved. The study included all cases notified during 2020 COVID-19 outbreak, versus the cases referred during the same period in 2019. Subgroup analyses for hospital-associated and travel-associated LD cases, as well as for lethality estimates were performed. RESULTS A sustained drop for incidence rate was confirmed, at EU-level (3.5 per 100,000 vs. 5.3 per 100,000) as well as in the national estimates. The decrease was particularly evident in Italy (RR 0.880, 95%CI 0.839 to 0.905), despite a transient surge in notification rates during the month of June, 2020. Subgroup analyses demonstrated a fall in travel-associated cases (-66.8% at EU level), while hospital-associated cases decreased in absolute number when compared to 2019, but where substantially stable in terms when compared to EU estimates. While Case Fatality Ratio increased in comparison with 2019, no significant trend was similarly identified in comparison to EU estimates. Conclusions. Lockdown measures have impacted on the epidemiology of LD in Europe during 2020, but some heterogeneities were identified both across the assessed countries, and the various subgroup. Even though the absolute number of total cases did substantially decrease in 2020 compared to 2019, the effect of non-pharmaceutical interventions was mostly indirect, through a reduced interaction of individuals with environments at potentially high-risk for human infections (e.g. hospitals, accommodation sites, etc.).
Collapse
Affiliation(s)
- Matteo Riccò
- Department of Public Health, Azienda USL-IRCCS di Reggio Emilia, Reggio Emilia, Italy
| |
Collapse
|
10
|
Brunello A, Civilini M, De Martin S, Felice A, Franchi M, Iacumin L, Saccomanno N, Vitacolonna N. Machine learning-assisted environmental surveillance of Legionella: A retrospective observational study in Friuli-Venezia Giulia region of Italy in the period 2002–2019. INFORMATICS IN MEDICINE UNLOCKED 2022. [DOI: 10.1016/j.imu.2021.100803] [Citation(s) in RCA: 2] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/30/2022] Open
|
11
|
De Giglio O, Napoli C, Diella G, Fasano F, Lopuzzo M, Apollonio F, D'Ambrosio M, Campanale C, Triggiano F, Caggiano G, Montagna MT. Integrated approach for legionellosis risk analysis in touristic-recreational facilities. ENVIRONMENTAL RESEARCH 2021; 202:111649. [PMID: 34252427 DOI: 10.1016/j.envres.2021.111649] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 05/13/2021] [Revised: 06/30/2021] [Accepted: 07/02/2021] [Indexed: 06/13/2023]
Abstract
Legionellosis is a severe pneumonia caused by the inhalation of aerosols containing Legionella, Gram-negative bacteria present in the water systems of touristic-recreational facilities. The purpose of this study was to develop a scoring tool to predict the risk of both environmental contamination and Legionnaires' disease cases in such facilities in the Apulia region of southern Italy. We analyzed 47 structural and management parameters/risk factors related to the buildings, water systems, and air conditioning at the facilities. A Poisson regression model was used to compute an overall risk score for each facility with respect to three outcomes: water samples positive for Legionella (risk score range: 7-54), water samples positive for Legionella with an average load exceeding 1000 colony-forming units per liter (CFU/L) (risk score range: 22-179,871), and clinical cases of Legionnaire's disease (risk score range: 6-31). The cut-off values for three outcomes were determined by receiver operating characteristic curves (first outcome, samples positive for Legionella in a touristic-recreational facility: 19; second outcome, samples positive for Legionella in a touristic-recreational facility with an average load exceeding 1000 CFU/L: 2062; third outcome, clinical cases of Legionnaire's disease in a touristic-recreational facility: 22). Above these values, there was a significant probability of observing the outcome. We constructed this predictive model using 70% of a large dataset (18 years of clinical and environmental surveillance) and tested the model on the remaining 30% of the dataset to demonstrate its reliability. Our model enables the assessment of risk for a touristic facility and the creation of a conceptual framework to link the risk analysis with prevention measures.
Collapse
Affiliation(s)
- Osvalda De Giglio
- Regional Reference Laboratory of Clinical and Environmental Surveillance of Legionellosis, Department of Biomedical Science and Human Oncology, University of Bari Aldo Moro, Piazza G. Cesare 11, 70124, Bari, Italy.
| | - Christian Napoli
- Department of Medical Surgical Sciences and Translational Medicine, "Sapienza" University of Rome, Via di Grottarossa 1035/1039, 00189, Rome, Italy.
| | - Giusy Diella
- Regional Reference Laboratory of Clinical and Environmental Surveillance of Legionellosis, Department of Biomedical Science and Human Oncology, University of Bari Aldo Moro, Piazza G. Cesare 11, 70124, Bari, Italy.
| | - Fabrizio Fasano
- Regional Reference Laboratory of Clinical and Environmental Surveillance of Legionellosis, Department of Biomedical Science and Human Oncology, University of Bari Aldo Moro, Piazza G. Cesare 11, 70124, Bari, Italy.
| | - Marco Lopuzzo
- Regional Reference Laboratory of Clinical and Environmental Surveillance of Legionellosis, Department of Biomedical Science and Human Oncology, University of Bari Aldo Moro, Piazza G. Cesare 11, 70124, Bari, Italy.
| | - Francesca Apollonio
- Regional Reference Laboratory of Clinical and Environmental Surveillance of Legionellosis, Department of Biomedical Science and Human Oncology, University of Bari Aldo Moro, Piazza G. Cesare 11, 70124, Bari, Italy.
| | - Marilena D'Ambrosio
- Regional Reference Laboratory of Clinical and Environmental Surveillance of Legionellosis, Department of Biomedical Science and Human Oncology, University of Bari Aldo Moro, Piazza G. Cesare 11, 70124, Bari, Italy.
| | - Carmen Campanale
- Regional Reference Laboratory of Clinical and Environmental Surveillance of Legionellosis, Department of Biomedical Science and Human Oncology, University of Bari Aldo Moro, Piazza G. Cesare 11, 70124, Bari, Italy.
| | - Francesco Triggiano
- Regional Reference Laboratory of Clinical and Environmental Surveillance of Legionellosis, Department of Biomedical Science and Human Oncology, University of Bari Aldo Moro, Piazza G. Cesare 11, 70124, Bari, Italy.
| | - Giuseppina Caggiano
- Regional Reference Laboratory of Clinical and Environmental Surveillance of Legionellosis, Department of Biomedical Science and Human Oncology, University of Bari Aldo Moro, Piazza G. Cesare 11, 70124, Bari, Italy.
| | - Maria Teresa Montagna
- Regional Reference Laboratory of Clinical and Environmental Surveillance of Legionellosis, Department of Biomedical Science and Human Oncology, University of Bari Aldo Moro, Piazza G. Cesare 11, 70124, Bari, Italy.
| |
Collapse
|
12
|
Riccò M, Peruzzi S, Ranzieri S, Giuri PG. Epidemiology of Legionnaires' Disease in Italy, 2004-2019: A Summary of Available Evidence. Microorganisms 2021; 9:microorganisms9112180. [PMID: 34835307 PMCID: PMC8624895 DOI: 10.3390/microorganisms9112180] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/24/2021] [Revised: 10/14/2021] [Accepted: 10/18/2021] [Indexed: 01/11/2023] Open
Abstract
Legionnaires’ disease (LD) incidence has been increasing in several European countries since 2011. Currently, Italy is experiencing high notification rates for LD, whose cause still remains scarcely understood. We sought to summarize the available evidence on the epidemiology of LD in Italy (2004–2019), characterizing the risk of LD by region, sex, age group, and settings of the case (i.e., community, healthcare, or travel-associated cases). Environmental factors (e.g., average air temperatures and relative humidity) were also included in a Poisson regression model in order to assess their potential role on the annual incidence of new LD cases. National surveillance data included a total of 23,554 LD cases occurring between 2004 and 2019 (70.4% of them were of male gender, 94.1% were aged 40 years and older), with age-adjusted incidence rates increasing from 1.053 cases per 100,000 in 2004 to 4.559 per 100,000 in 2019. The majority of incident cases came from northern Italy (43.2% from northwestern Italy, 25.6% from northeastern Italy). Of these, 5.9% were healthcare-related, and 21.1% were travel-associated. A case-fatality ratio of 5.2% was calculated for the whole of the assessed timeframe, with a pooled estimate for mortality of 0.122 events per 100,000 population per year. Poisson regression analysis was associated with conflicting results, as any increase in average air temperature resulted in reduced risk for LD cases (Incidence Rate Ratio [IRR] 0.807, 95% Confidence Interval [95% CI] 0.744–0.874), while higher annual income in older individuals was associated with an increased IRR (1.238, 95% CI 1.134–1.351). The relative differences in incidence between Italian regions could not be explained by demographic factors (i.e., age and sex distribution of the population), and also a critical reappraisal of environmental factors failed to substantiate both the varying incidence across the country and the decennial trend we were able to identify.
Collapse
Affiliation(s)
- Matteo Riccò
- Servizio di Prevenzione e Sicurezza Negli Ambienti di Lavoro (SPSAL), AUSL—IRCCS di Reggio Emilia, Via Amendola n.2, I-42022 Reggio Emilia, Italy
- Correspondence: or ; Tel.: +39-3392-994-343 or +39-522-837-587
| | - Simona Peruzzi
- Laboratorio Analisi Chimico Cliniche e Microbiologiche, Ospedale Civile di Guastalla, AUSL—IRCCS di Reggio Emilia, I-42016 Guastalla, Italy;
| | - Silvia Ranzieri
- Department of Medicine and Surgery, School of Occupational Medicine, University of Parma, Via Gramsci n.14, I-43123 Parma, Italy;
| | - Pasquale Gianluca Giuri
- Dipartimento Internistico Interaziendale, Struttura Operativa Semplice Dipartimentale “Medicina Infettivologica”, AUSL—IRCCS di Reggio Emilia, Ospedale “Sant’Anna”, I-42035 Castelnovo ne’ Monti, Italy;
| |
Collapse
|
13
|
Salinas MB, Fenoy S, Magnet A, Vaccaro L, Gomes TD, Hurtado C, Ollero D, Valdivieso E, Del Águila C, Pozuelo MJ, Izquierdo F. Are pathogenic Legionella non-pneumophila a common bacteria in Water Distribution Networks? WATER RESEARCH 2021; 196:117013. [PMID: 33813251 DOI: 10.1016/j.watres.2021.117013] [Citation(s) in RCA: 10] [Impact Index Per Article: 3.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 12/02/2020] [Revised: 02/16/2021] [Accepted: 03/04/2021] [Indexed: 05/22/2023]
Abstract
The present study analyzes at the national level, the presence of circulating Legionella in the artificial aquatic systems of different facilities of all of them state-owned centers throughout Spain for 12 months. 1754 water samples from various state-owned centers were collected from January to December 2014. Samples were collected from the cooling towers and evaporative condensers (CTC), and water distribution networks such as domestic hot water (DHW), cold water for human consumption (CW), sprinkler irrigation systems (SIS), fire sprinkler systems (FSS), and water from decorative fountains (DF). All these facilities are considered, according to current regulations, as potential amplifying systems for bacteria and possible sources of infection by the generation of droplets and aerosols. The isolation and counting of Legionella in water samples was carried out using microbiological culture following the international normative UNE-EN-ISO 11,731:2007 (ISO 11,731:1998) and UNE-EN ISO 8199:2008 (ISO 8199:2005).The quantification of Legionella colonization, the annual distribution, and the geographical distribution of the Legionella isolates recovered in the water were analyzed. Besides, molecular techniques were used for the characterization of the Legionella non-pneumophila isolates. Legionella was recovered from 15.79% of the analyzed water samples. High colonization was more frequently detected in water samples from CTC, DHW, CW, and DF. Regarding the geographic distribution, positive samples of Legionella were obtained in 14 of the 18 Spanish locations analyzed. Legionella non-pneumophila was the most prevalent and was isolated from water samples from 13 different geographical locations (72%). Legionella anisa and Legionella jordanis were the most frequently non-pneumophila species isolated. Legionella donaldsonii was isolated for the first time in the water distribution networks in Spain. Legionella pneumophila sg 2-14 was detected in 13 locations and Legionella pneumophila sg 1 in 11 locations. Therefore, our study concludes that the presence of Legionella pneumophila and Legionella non-pneumophila species in these systems can be a potential threat to public health and should be examined thoroughly with complementary techniques, such as molecular techniques as a screen for routine diagnosis.
Collapse
Affiliation(s)
- Mireya Beatriz Salinas
- Facultad de Farmacia, Universidad San Pablo-CEU, CEU Universities, Urbanización Montepríncipe, 28660 Boadilla del Monte, Madrid, España
| | - Soledad Fenoy
- Facultad de Farmacia, Universidad San Pablo-CEU, CEU Universities, Urbanización Montepríncipe, 28660 Boadilla del Monte, Madrid, España
| | - Angela Magnet
- Facultad de Farmacia, Universidad San Pablo-CEU, CEU Universities, Urbanización Montepríncipe, 28660 Boadilla del Monte, Madrid, España
| | - Lucianna Vaccaro
- Facultad de Farmacia, Universidad San Pablo-CEU, CEU Universities, Urbanización Montepríncipe, 28660 Boadilla del Monte, Madrid, España
| | - Thiago Ds Gomes
- Facultad de Farmacia, Universidad San Pablo-CEU, CEU Universities, Urbanización Montepríncipe, 28660 Boadilla del Monte, Madrid, España
| | - Carolina Hurtado
- Facultad de Farmacia, Universidad San Pablo-CEU, CEU Universities, Urbanización Montepríncipe, 28660 Boadilla del Monte, Madrid, España
| | - Dolores Ollero
- Facultad de Farmacia, Universidad San Pablo-CEU, CEU Universities, Urbanización Montepríncipe, 28660 Boadilla del Monte, Madrid, España
| | - Elizabeth Valdivieso
- Facultad de Farmacia, Universidad San Pablo-CEU, CEU Universities, Urbanización Montepríncipe, 28660 Boadilla del Monte, Madrid, España
| | - Carmen Del Águila
- Facultad de Farmacia, Universidad San Pablo-CEU, CEU Universities, Urbanización Montepríncipe, 28660 Boadilla del Monte, Madrid, España
| | - María José Pozuelo
- Facultad de Farmacia, Universidad San Pablo-CEU, CEU Universities, Urbanización Montepríncipe, 28660 Boadilla del Monte, Madrid, España
| | - Fernando Izquierdo
- Facultad de Farmacia, Universidad San Pablo-CEU, CEU Universities, Urbanización Montepríncipe, 28660 Boadilla del Monte, Madrid, España.
| |
Collapse
|