1
|
Joshi P, Shinde A, Sudhiram S, Sarangi BR, Mani NK. Wearable threads for monitoring sanitizer quality using dye displacement assay. RSC Adv 2024; 14:37155-37163. [PMID: 39569111 PMCID: PMC11577342 DOI: 10.1039/d4ra04379k] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/15/2024] [Accepted: 11/06/2024] [Indexed: 11/22/2024] Open
Abstract
This study employs zero-cost (≈0.01 $) and durable thread-based devices to evaluate the quality of simulated and commercial sanitizer samples through dye displacement assay (DDA). A diverse range of sanitizer compositions, including ethanol concentrations of 55%, 75%, and 95% (v/v), were analysed. This investigation encompasses an assessment of the marker type (Doms and Hauser brands) on the migration distance of the dye region marked on thread devices. Our results demonstrate a proportional increase in the migration distance of the dye with increasing ethanol concentrations due to a decrease in the coefficient of viscosity and solvation power of ethanol on dye molecules. Additionally, a field trial for the thorough assessment of commercial sanitizer quality using thread-based devices further underscores the efficacy of this methodology. A calibration plot for a braided thread with Doms marker dye provides a reliable means to quantitatively assess the ethanol content in different commercial sanitizer compositions. Our findings collectively highlight the significance of this innovative method as a valuable tool for quality control and assessment for public health and hygiene as well as for preparing us for another pandemic.
Collapse
Affiliation(s)
- Pratham Joshi
- Microfluidics, Sensors and Diagnostics (μSenD) Laboratory, Centre for Microfluidics, Biomarkers, Photoceutics and Sensors (μBioPS), Department of Biotechnology, Manipal Institute of Technology, Manipal Academy of Higher Education Manipal Karnataka 576104 India
- Innotech Manipal, Manipal Institute of Technology, Manipal Academy of Higher Education Manipal Karnataka 576104 India
| | - Akhiya Shinde
- Microfluidics, Sensors and Diagnostics (μSenD) Laboratory, Centre for Microfluidics, Biomarkers, Photoceutics and Sensors (μBioPS), Department of Biotechnology, Manipal Institute of Technology, Manipal Academy of Higher Education Manipal Karnataka 576104 India
| | - Sukanya Sudhiram
- Physical and Chemical Biology Laboratory, Department of Physics, Indian Institute of Technology Palakkad Kerala 678623 India
| | - Bibhu Ranjan Sarangi
- Physical and Chemical Biology Laboratory, Department of Physics, Indian Institute of Technology Palakkad Kerala 678623 India
- Biological Sciences and Engineering, Indian Institute of Technology Palakkad Kerala 678623 India
| | - Naresh Kumar Mani
- Microfluidics, Sensors and Diagnostics (μSenD) Laboratory, Centre for Microfluidics, Biomarkers, Photoceutics and Sensors (μBioPS), Department of Biotechnology, Manipal Institute of Technology, Manipal Academy of Higher Education Manipal Karnataka 576104 India
- Innotech Manipal, Manipal Institute of Technology, Manipal Academy of Higher Education Manipal Karnataka 576104 India
| |
Collapse
|
2
|
Gomes Torres ACMB, Mathias C, Baal SCS, Kohler AF, Cunha ML, Blanes L. Advancements in LAMP-Based Diagnostics: Emerging Techniques and Applications in Viral Detection with a Focus on Herpesviruses in Transplant Patient Management. Int J Mol Sci 2024; 25:11506. [PMID: 39519059 PMCID: PMC11546353 DOI: 10.3390/ijms252111506] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/11/2024] [Revised: 10/22/2024] [Accepted: 10/23/2024] [Indexed: 11/16/2024] Open
Abstract
Loop-mediated isothermal amplification (LAMP) is a highly effective molecular diagnostic technique, particularly advantageous for point-of-care (POC) settings. In recent years, LAMP has expanded to include various adaptations such as DARQ-LAMP, QUASR, FLOS-LAMP, displacement probes and molecular beacons. These methods enable multiplex detection of multiple targets in a single reaction, enhancing cost-effectiveness and diagnostic efficiency. Consequently, LAMP has gained significant traction in diagnosing diverse viruses, notably during the COVID-19 pandemic. However, its application for detecting Herpesviridae remains relatively unexplored. This group of viruses is of particular interest due to their latency and potential reactivation, crucial for immunocompromised patients, including organ and hematopoietic stem cell transplant recipients. This review highlights recent advancements in LAMP for virus diagnosis and explores current research trends and future prospects, emphasizing the detection challenges posed by Herpesviridae.
Collapse
Affiliation(s)
| | - Carolina Mathias
- Post-Graduation Program in Genetics, Department of Genetics, Federal University of Parana, Curitiba 81530-980, Brazil; (C.M.); (S.C.S.B.); (A.F.K.); (M.L.C.)
| | - Suelen Cristina Soares Baal
- Post-Graduation Program in Genetics, Department of Genetics, Federal University of Parana, Curitiba 81530-980, Brazil; (C.M.); (S.C.S.B.); (A.F.K.); (M.L.C.)
| | - Ana Flávia Kohler
- Post-Graduation Program in Genetics, Department of Genetics, Federal University of Parana, Curitiba 81530-980, Brazil; (C.M.); (S.C.S.B.); (A.F.K.); (M.L.C.)
| | - Mylena Lemes Cunha
- Post-Graduation Program in Genetics, Department of Genetics, Federal University of Parana, Curitiba 81530-980, Brazil; (C.M.); (S.C.S.B.); (A.F.K.); (M.L.C.)
| | - Lucas Blanes
- Laboratory for Applied Science and Technology in Health, Carlos Chagas Institute, Oswaldo Cruz Foundation (Fiocruz), Curitiba 81350-010, Brazil;
| |
Collapse
|
3
|
Crego-Vicente B, del Olmo MD, Muro A, Fernández-Soto P. Multiplexing LAMP Assays: A Methodological Review and Diagnostic Application. Int J Mol Sci 2024; 25:6374. [PMID: 38928080 PMCID: PMC11203869 DOI: 10.3390/ijms25126374] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/30/2024] [Revised: 05/27/2024] [Accepted: 06/06/2024] [Indexed: 06/28/2024] Open
Abstract
The loop-mediated isothermal amplification (LAMP) technique is a great alternative to PCR-based methods, as it is fast, easy to use and works with high sensitivity and specificity without the need for expensive instruments. However, one of the limitations of LAMP is difficulty in achieving the simultaneous detection of several targets in a single tube, as the methodologies that allow this rely on fluorogenic probes containing specific target sequences, complicating their adaptation and the optimization of assays. Here, we summarize different methods for the development of multiplex LAMP assays based on sequence-specific detection, illustrated with a schematic representation of the technique, and evaluate their practical application based on the real-time detection and quantification of results, the possibility to visualize the results at a glance, the prior stabilization of reaction components, promoting the point-of-care use, the maximum number of specific targets amplified, and the validation of the technique in clinical samples. The various LAMP multiplexing methodologies differ in their operating conditions and mechanism. Each methodology has its advantages and disadvantages, and the choice among them will depend on specific application interests.
Collapse
Affiliation(s)
| | | | - Antonio Muro
- Infectious and Tropical Diseases Research Group (e-INTRO), Biomedical Research Institute of Salamanca Research Centre for Tropical Diseases at the University of Salamanca (IBSAL-CIETUS), Faculty of Pharmacy, University of Salamanca, 37007 Salamanca, Spain; (B.C.-V.); (M.D.d.O.)
| | - Pedro Fernández-Soto
- Infectious and Tropical Diseases Research Group (e-INTRO), Biomedical Research Institute of Salamanca Research Centre for Tropical Diseases at the University of Salamanca (IBSAL-CIETUS), Faculty of Pharmacy, University of Salamanca, 37007 Salamanca, Spain; (B.C.-V.); (M.D.d.O.)
| |
Collapse
|
4
|
Kim D, DeBriere TJ, Eastmond BH, Alomar AA, Yaren O, McCarter J, Bradley KM, Benner SA, Alto BW, Burkett-Cadena ND. Rapid detection of West Nile and Dengue viruses from mosquito saliva by loop-mediated isothermal amplification and displaced probes. PLoS One 2024; 19:e0298805. [PMID: 38394282 PMCID: PMC10889885 DOI: 10.1371/journal.pone.0298805] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/01/2023] [Accepted: 01/30/2024] [Indexed: 02/25/2024] Open
Abstract
Arthropod-borne viruses are major causes of human and animal disease, especially in endemic low- and middle-income countries. Mosquito-borne pathogen surveillance is essential for risk assessment and vector control responses. Sentinel chicken serosurveillance (antibody testing) and mosquito pool screening (by RT-qPCR or virus isolation) are currently used to monitor arbovirus transmission, however substantial time lags of seroconversion and/or laborious mosquito identification and RNA extraction steps sacrifice their early warning value. As a consequence, timely vector control responses are compromised. Here, we report on development of a rapid arbovirus detection system whereby adding sucrose to reagents of loop-mediated isothermal amplification with displaced probes (DP-LAMP) elicits infectious mosquitoes to feed directly upon the reagent mix and expectorate viruses into the reagents during feeding. We demonstrate that RNA from pathogenic arboviruses (West Nile and Dengue viruses) transmitted in the infectious mosquito saliva was detectable rapidly (within 45 minutes) without RNA extraction. Sucrose stabilized viral RNA at field temperatures for at least 48 hours, important for transition of this system to practical use. After thermal treatment, the DP-LAMP could be reliably visualized by a simple optical image sensor to distinguish between positive and negative samples based on fluorescence intensity. Field application of this technology could fundamentally change conventional arbovirus surveillance methods by eliminating laborious RNA extraction steps, permitting arbovirus monitoring from additional sites, and substantially reducing time needed to detect circulating pathogens.
Collapse
Affiliation(s)
- Dongmin Kim
- Florida Medical Entomology Laboratory, University of Florida, Vero Beach, Florida, United States of America
| | | | - Bradley H. Eastmond
- Florida Medical Entomology Laboratory, University of Florida, Vero Beach, Florida, United States of America
| | - Abdullah A. Alomar
- Florida Medical Entomology Laboratory, University of Florida, Vero Beach, Florida, United States of America
| | - Ozlem Yaren
- Firebird Biomolecular Sciences LLC, Alachua, Florida, United States of America
- Foundation for Applied Molecular Evolution, Alachua, Florida, United States of America
| | - Jacquelyn McCarter
- Firebird Biomolecular Sciences LLC, Alachua, Florida, United States of America
- Foundation for Applied Molecular Evolution, Alachua, Florida, United States of America
| | - Kevin M. Bradley
- Foundation for Applied Molecular Evolution, Alachua, Florida, United States of America
| | - Steven A. Benner
- Firebird Biomolecular Sciences LLC, Alachua, Florida, United States of America
- Foundation for Applied Molecular Evolution, Alachua, Florida, United States of America
| | - Barry W. Alto
- Florida Medical Entomology Laboratory, University of Florida, Vero Beach, Florida, United States of America
| | - Nathan D. Burkett-Cadena
- Florida Medical Entomology Laboratory, University of Florida, Vero Beach, Florida, United States of America
| |
Collapse
|
5
|
Sritong N, Ngo WW, Ejendal KFK, Linnes JC. Development of an integrated sample amplification control for salivary point-of-care pathogen testing. Anal Chim Acta 2024; 1287:342072. [PMID: 38182338 PMCID: PMC10860388 DOI: 10.1016/j.aca.2023.342072] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/03/2023] [Revised: 11/20/2023] [Accepted: 11/25/2023] [Indexed: 01/07/2024]
Abstract
BACKGROUND The COVID-19 pandemic has led to a rise in point-of-care (POC) and home-based tests, but concerns over usability, accuracy, and effectiveness have arisen. The incorporation of internal amplification controls (IACs), essential control for translational POC diagnostics, could mitigate false-negative and false-positive results due to sample matrix interference or inhibition. Although emerging POC nucleic acid amplification tests (NAATs) for detecting SARS-CoV-2 show impressive analytical sensitivity in the lab, the assessment of clinical accuracy with IACs is often overlooked. In some cases, the IACs were run spatially, complicating assay workflow. Therefore, the multiplex assay for pathogen and IAC is needed. RESULTS We developed a one-pot duplex reverse transcriptase loop-mediated isothermal amplification (RT-LAMP) assay for saliva samples, a non-invasive and simple collected specimen for POC NAATs. The ORF1ab gene of SARS-CoV-2 was used as a target and a human 18S ribosomal RNA in human saliva was employed as an IAC to ensure clinical reliability of the RT-LAMP assay. The optimized assay could detect SARS-CoV-2 viral particles down to 100 copies/μL of saliva within 30 min without RNA extraction. The duplex RT-LAMP for SARS-CoV-2 and IAC is successfully amplified in the same reaction without cross-reactivity. The valid results were easily visualized in triple-line lateral flow immunoassay, in which two lines (flow control and IAC lines) represent valid negative results and three lines (flow control, IAC, and test line) represent valid positive results. This duplex assay demonstrated a clinical sensitivity of 95%, specificity of 100%, and accuracy of 96% in 30 clinical saliva samples. SIGNIFICANCE IACs play a crucial role in ensuring user confidence with respect to the accuracy and reliability of at-home and POC molecular diagnostics. We demonstrated the multiplex capability of SARS-COV-2 and human18S ribosomal RNA RT-LAMP without complicating assay design. This generic platform can be extended in a similar manner to include human18S ribosomal RNA IACs into different clinical sample matrices.
Collapse
Affiliation(s)
- Navaporn Sritong
- Weldon School of Biomedical Engineering, Purdue University, West Lafayette, IN, USA
| | - Winston Wei Ngo
- Weldon School of Biomedical Engineering, Purdue University, West Lafayette, IN, USA
| | - Karin F K Ejendal
- Weldon School of Biomedical Engineering, Purdue University, West Lafayette, IN, USA
| | - Jacqueline C Linnes
- Weldon School of Biomedical Engineering, Purdue University, West Lafayette, IN, USA; Department of Public Health, Purdue University, West Lafayette, IN, USA.
| |
Collapse
|
6
|
Sritong N, Ngo WW, Ejendal KFK, Linnes JC. Development of an Integrated Sample Amplification Control for Salivary Point-of-Care Pathogen Testing. MEDRXIV : THE PREPRINT SERVER FOR HEALTH SCIENCES 2023:2023.10.03.23296477. [PMID: 37873363 PMCID: PMC10593008 DOI: 10.1101/2023.10.03.23296477] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 10/25/2023]
Abstract
Background The COVID-19 pandemic has led to a rise in point-of-care (POC) and home-based tests, but concerns over usability, accuracy, and effectiveness have arisen. The incorporation of internal amplification controls (IACs), essential control for translational POC diagnostics, could mitigate false-negative and false-positive results due to sample matrix interference or inhibition. Although emerging POC nucleic acid amplification tests (NAATs) for detecting SARS-CoV-2 show impressive analytical sensitivity in the lab, the assessment of clinical accuracy with IACs is often overlooked. In some cases, the IACs were run spatially, complicating assay workflow. Therefore, the multiplex assay for pathogen and IAC is needed. Results We developed a one-pot duplex reverse transcriptase loop-mediated isothermal amplification (RT-LAMP) assay for saliva samples, a non-invasive and simple collected specimen for POC NAATs. The ORF1ab gene of SARS-CoV-2 was used as a target and a human 18S ribosomal RNA in human saliva was employed as an IAC to ensure clinical reliability of the RT-LAMP assay. The optimized assay could detect SARS-CoV-2 viral particles down to 100 copies/μL of saliva within 30 minutes without RNA extraction. The duplex RT-LAMP for SARS-CoV-2 and IAC is successfully amplified in the same reaction without cross-reactivity. The valid results were easily visualized in triple-line lateral flow immunoassay, in which two lines (flow control and IAC lines) represent valid negative results and three lines (flow control, IAC, and test line) represent valid positive results. This duplex assay demonstrated a clinical sensitivity of 95%, specificity of 100%, and accuracy of 96% in 30 clinical saliva samples. Significance IACs play a crucial role in ensuring user confidence with respect to the accuracy and reliability of at-home and POC molecular diagnostics. We demonstrated the multiplex capability of SARS-COV-2 and human18S ribosomal RNA RT-LAMP without complicating assay design. This generic platform can be extended in a similar manner to include human18S ribosomal RNA IACs into different clinical sample matrices.
Collapse
Affiliation(s)
- Navaporn Sritong
- Weldon School of Biomedical Engineering, Purdue University, West Lafayette, IN, USA
| | - Winston Wei Ngo
- Weldon School of Biomedical Engineering, Purdue University, West Lafayette, IN, USA
| | - Karin F. K. Ejendal
- Weldon School of Biomedical Engineering, Purdue University, West Lafayette, IN, USA
| | - Jacqueline C. Linnes
- Weldon School of Biomedical Engineering, Purdue University, West Lafayette, IN, USA
- Department of Public Health, Purdue University, West Lafayette, IN, USA
| |
Collapse
|
7
|
Yaren O, McCarter J, Morris AR, Bradley KM, Karalkar NB, McLendon DC, Kim D, Eastmond BH, Burkett-Cadena ND, Alto BW, Benner SA. Multiplex Surveillance Kit Using Sweetened Solid Support to Detect Arboviruses Isothermally in Mosquito Saliva from the Field. Anal Chem 2023; 95:10736-10743. [PMID: 37390024 DOI: 10.1021/acs.analchem.3c01735] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 07/02/2023]
Abstract
Recently reported "displaceable probe" loop amplification (DP-LAMP) architecture has shown to amplify viral RNA from SARS-CoV-2 with little sample processing. The architecture allows signals indicating the presence of target nucleic acids to be spatially separated, and independent in sequence, from the complicated concatemer that LAMP processes create as part of their amplification process. This makes DP-LAMP an attractive molecular strategy to integrate with trap and sampling innovations to detect RNA from arboviruses carried by mosquitoes in the field. These innovations include (a) development of organically produced carbon dioxide with ethylene carbonate as a bait deployable in mosquito trap, avoiding the need for dry ice, propane tanks, or inorganic carbonates and (b) a process that induces mosquitoes to lay virus-infected saliva on a quaternary ammonium-functionalized paper (Q-paper) matrix, where (c) the matrix (i) inactivates the deposited viruses, (ii) releases their RNA, and (iii) captures viral RNA in a form that keeps it stable for days at ambient temperatures. We report this integration here, with a surprisingly simple workflow. DP-LAMP with a reverse transcriptase was found to amplify arboviral RNA directly from Q-paper, without requiring a separate elution step. This capture-amplification-detection architecture can be multiplexed, with the entire system integrated into a device that can support a campaign of surveillance, in the wild outdoors, that reports the prevalence of arboviruses from field-captured mosquitoes.
Collapse
Affiliation(s)
- Ozlem Yaren
- Foundation for Applied Molecular Evolution, Alachua, Florida 32615-9495, United States
- Firebird Biomolecular Sciences LLC, Alachua, Florida 32615, United States
| | - Jacquelyn McCarter
- Foundation for Applied Molecular Evolution, Alachua, Florida 32615-9495, United States
- Firebird Biomolecular Sciences LLC, Alachua, Florida 32615, United States
| | - Andrew R Morris
- Foundation for Applied Molecular Evolution, Alachua, Florida 32615-9495, United States
- College of Medicine, University of Florida, Gainesville, Florida 32611,, USA
| | - Kevin M Bradley
- Foundation for Applied Molecular Evolution, Alachua, Florida 32615-9495, United States
| | - Nilesh B Karalkar
- Foundation for Applied Molecular Evolution, Alachua, Florida 32615-9495, United States
| | - Daniel C McLendon
- Firebird Biomolecular Sciences LLC, Alachua, Florida 32615, United States
| | - Dongmin Kim
- Florida Medical Entomology Laboratory, University of Florida, Vero Beach, Florida 32962-4699, United States
| | - Bradley H Eastmond
- Florida Medical Entomology Laboratory, University of Florida, Vero Beach, Florida 32962-4699, United States
- Thermo Fisher Scientific, Frederick, Maryland 02451, USA
| | - Nathan D Burkett-Cadena
- Florida Medical Entomology Laboratory, University of Florida, Vero Beach, Florida 32962-4699, United States
| | - Barry W Alto
- Florida Medical Entomology Laboratory, University of Florida, Vero Beach, Florida 32962-4699, United States
| | - Steven A Benner
- Foundation for Applied Molecular Evolution, Alachua, Florida 32615-9495, United States
- Firebird Biomolecular Sciences LLC, Alachua, Florida 32615, United States
| |
Collapse
|
8
|
Sritong N, Sala de Medeiros M, Basing LA, Linnes JC. Promise and perils of paper-based point-of-care nucleic acid detection for endemic and pandemic pathogens. LAB ON A CHIP 2023; 23:888-912. [PMID: 36688463 PMCID: PMC10028599 DOI: 10.1039/d2lc00554a] [Citation(s) in RCA: 12] [Impact Index Per Article: 6.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/27/2023]
Abstract
From HIV and influenza to emerging pathogens like COVID-19, each new infectious disease outbreak has highlighted the need for massively-scalable testing that can be performed outside centralized laboratory settings at the point-of-care (POC) in order to prevent, track, and monitor endemic and pandemic threats. Nucleic acid amplification tests (NAATs) are highly sensitive and can be developed and scaled within weeks while protein-based rapid tests require months for production. Combining NAATs with paper-based detection platforms are promising due to the manufacturability, scalability, and simplicity of each of these components. Typically, paper-based NAATs consist of three sequential steps: sample collection and preparation, amplification of DNA or RNA from pathogens of interest, and detection. However, these exist within a larger ecosystem of sample collection and interpretation workflow, usability, and manufacturability which can be vastly perturbed during a pandemic emergence. This review aims to explore the challenges of paper-based NAATs covering sample-to-answer procedures along with three main types of clinical samples; blood, urine, and saliva, as well as broader operational, scale up, and regulatory aspects of device development and implementation. To fill the technological gaps in paper-based NAATs, a sample-in-result-out system that incorporates the integrated sample collection, sample preparation, and integrated internal amplification control while also balancing needs of users and manufacturability upfront in the early design process is required.
Collapse
Affiliation(s)
- Navaporn Sritong
- Weldon School of Biomedical Engineering, Purdue University, West Lafayette, IN, USA.
| | | | - Laud Anthony Basing
- Department of Medical Diagnostics, Kwame Nkrumah University of Science and Technology, Kumasi, Ashanti, Ghana
| | - Jacqueline C Linnes
- Weldon School of Biomedical Engineering, Purdue University, West Lafayette, IN, USA.
| |
Collapse
|
9
|
Crego-Vicente B, Fernández-Soto P, García-Bernalt Diego J, Febrer-Sendra B, Muro A. Development of a Duplex LAMP Assay with Probe-Based Readout for Simultaneous Real-Time Detection of Schistosoma mansoni and Strongyloides spp. -A Laboratory Approach to Point-Of-Care. Int J Mol Sci 2023; 24:ijms24010893. [PMID: 36614336 PMCID: PMC9821331 DOI: 10.3390/ijms24010893] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/17/2022] [Revised: 12/22/2022] [Accepted: 12/30/2022] [Indexed: 01/06/2023] Open
Abstract
Loop-mediated isothermal amplification (LAMP) is the most popular technology for point-of-care testing applications due its rapid, sensitive and specific detection with simple instrumentation compared to PCR-based methods. Many systems for reading the results of LAMP amplifications exist, including real-time fluorescence detection using fluorophore-labelled probes attached to oligonucleotide sequences complementary to the target nucleic acid. This methodology allows the simultaneous detection of multiple targets (multiplexing) in one LAMP assay. A method for multiplexing LAMP is the amplification by release of quenching (DARQ) technique by using a 5'-quencher modified LAMP primer annealed to 3'-fluorophore-labelled acting as detection oligonucleotide. The main application of multiplex LAMP is the rapid and accurate diagnosis of infectious diseases, allowing differentiation of co-infecting pathogens in a single reaction. Schistosomiasis, caused among other species by Schistosoma mansoni and strongyloidiasis, caused by Strongyloides stercoralis, are the most common helminth-parasite infections worldwide with overlapping distribution areas and high possibility of coinfections in the human population. It would be of great interest to develop a duplex LAMP to detect both pathogens in the same reaction. In this study, we investigate the use of our two previously developed and well-stablished LAMP assays for S. mansoni and Strongyloides spp. DNA detection in a new duplex real-time eight-primer system based on a modified DARQ probe method that can be performed in a portable isothermal fluorimeter with minimal laboratory resources. We also applied a strategy to stabilize the duplexed DARQ-LAMP mixtures at room temperature for use as ready-to-use formats facilitating analysis in field settings as point-of-care diagnostics for schistosomiasis and strongyloidiasis.
Collapse
|
10
|
Warneford-Thomson R, Shah PP, Lundgren P, Lerner J, Morgan J, Davila A, Abella BS, Zaret K, Schug J, Jain R, Thaiss CA, Bonasio R. A LAMP sequencing approach for high-throughput co-detection of SARS-CoV-2 and influenza virus in human saliva. eLife 2022; 11:69949. [PMID: 35532013 PMCID: PMC9084890 DOI: 10.7554/elife.69949] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/05/2021] [Accepted: 04/24/2022] [Indexed: 12/02/2022] Open
Abstract
The COVID-19 pandemic has created an urgent need for rapid, effective, and low-cost SARS-CoV-2 diagnostic testing. Here, we describe COV-ID, an approach that combines RT-LAMP with deep sequencing to detect SARS-CoV-2 in unprocessed human saliva with a low limit of detection (5–10 virions). Based on a multi-dimensional barcoding strategy, COV-ID can be used to test thousands of samples overnight in a single sequencing run with limited labor and laboratory equipment. The sequencing-based readout allows COV-ID to detect multiple amplicons simultaneously, including key controls such as host transcripts and artificial spike-ins, as well as multiple pathogens. Here, we demonstrate this flexibility by simultaneous detection of 4 amplicons in contrived saliva samples: SARS-CoV-2, influenza A, human STATHERIN, and an artificial SARS calibration standard. The approach was validated on clinical saliva samples, where it showed excellent agreement with RT-qPCR. COV-ID can also be performed directly on saliva absorbed on filter paper, simplifying collection logistics and sample handling.
Collapse
Affiliation(s)
- Robert Warneford-Thomson
- Graduate Group in Biochemistry and Biophysics, University of Pennsylvania Perelman School of Medicine, Philadelphia, United States.,Epigenetics Institute, University of Pennsylvania Perelman School of Medicine, Philadelphia, United States.,Department of Cell and Developmental Biology, University of Pennsylvania Perelman School of Medicine, Philadelphia, United States
| | - Parisha P Shah
- Epigenetics Institute, University of Pennsylvania Perelman School of Medicine, Philadelphia, United States.,Department of Cell and Developmental Biology, University of Pennsylvania Perelman School of Medicine, Philadelphia, United States.,Department of Medicine, University of Pennsylvania Perelman School of Medicine, Philadelphia, United States
| | - Patrick Lundgren
- Department of Microbiology, University of Pennsylvania Perelman School of Medicine, Philadelphia, United States
| | - Jonathan Lerner
- Department of Cell and Developmental Biology, University of Pennsylvania Perelman School of Medicine, Philadelphia, United States
| | - Jason Morgan
- Department of Emergency Medicine and Penn Acute Research Collaboration, University of Pennsylvania Perelman School of Medicine, Philadelphia, United States
| | - Antonio Davila
- Department of Emergency Medicine and Penn Acute Research Collaboration, University of Pennsylvania Perelman School of Medicine, Philadelphia, United States.,University of Pennsylvania School of Nursing, Philadelphia, United States
| | - Benjamin S Abella
- Department of Emergency Medicine and Penn Acute Research Collaboration, University of Pennsylvania Perelman School of Medicine, Philadelphia, United States
| | - Kenneth Zaret
- Epigenetics Institute, University of Pennsylvania Perelman School of Medicine, Philadelphia, United States.,Department of Cell and Developmental Biology, University of Pennsylvania Perelman School of Medicine, Philadelphia, United States
| | - Jonathan Schug
- Next-Generation Sequencing Core, Department of Genetics, University of Pennsylvania Perelman School of Medicine, Philadelphia, United States
| | - Rajan Jain
- Epigenetics Institute, University of Pennsylvania Perelman School of Medicine, Philadelphia, United States.,Department of Cell and Developmental Biology, University of Pennsylvania Perelman School of Medicine, Philadelphia, United States.,Department of Medicine, University of Pennsylvania Perelman School of Medicine, Philadelphia, United States
| | - Christoph A Thaiss
- Department of Microbiology, University of Pennsylvania Perelman School of Medicine, Philadelphia, United States
| | - Roberto Bonasio
- Epigenetics Institute, University of Pennsylvania Perelman School of Medicine, Philadelphia, United States.,Department of Cell and Developmental Biology, University of Pennsylvania Perelman School of Medicine, Philadelphia, United States
| |
Collapse
|
11
|
Davidson JL, Wang J, Maruthamuthu MK, Dextre A, Pascual-Garrigos A, Mohan S, Putikam SVS, Osman FOI, McChesney D, Seville J, Verma MS. A paper-based colorimetric molecular test for SARS-CoV-2 in saliva. BIOSENSORS & BIOELECTRONICS: X 2021; 9:100076. [PMID: 34423284 PMCID: PMC8364207 DOI: 10.1016/j.biosx.2021.100076] [Citation(s) in RCA: 34] [Impact Index Per Article: 8.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 06/15/2021] [Revised: 08/09/2021] [Accepted: 08/10/2021] [Indexed: 04/16/2023]
Abstract
Herein, we describe the development of a paper-based device to detect nucleic acids of pathogens of interest in complex samples using loop-mediated isothermal amplification (LAMP) by producing a colorimetric response visible to the human eye. To demonstrate the utility of this device in emerging public health emergencies, we developed and optimized our device to detect SARS-CoV-2 in human saliva without preprocessing. The resulting device was capable of detecting the virus within 60 min and had an analytical sensitivity of 97% and a specificity of 100% with a limit of detection of 200 genomic copies/μL of patient saliva using image analysis. The device consists of a configurable number of reaction zones constructed of Grade 222 chromatography paper separated by 20 mil polystyrene spacers attached to a Melinex® backing via an ARclean® double-sided adhesive. The resulting device is easily configurable to detect multiple targets and has the potential to detect a variety of pathogens simply by changing the LAMP primer sets.
Collapse
Affiliation(s)
- Josiah Levi Davidson
- Department of Agricultural and Biological Engineering, Purdue University, West Lafayette, IN, 47907, USA
- Birck Nanotechnology Center, Purdue University, West Lafayette, IN, 47907, USA
| | - Jiangshan Wang
- Department of Agricultural and Biological Engineering, Purdue University, West Lafayette, IN, 47907, USA
- Birck Nanotechnology Center, Purdue University, West Lafayette, IN, 47907, USA
| | - Murali Kannan Maruthamuthu
- Department of Agricultural and Biological Engineering, Purdue University, West Lafayette, IN, 47907, USA
- Birck Nanotechnology Center, Purdue University, West Lafayette, IN, 47907, USA
| | - Andres Dextre
- Department of Agricultural and Biological Engineering, Purdue University, West Lafayette, IN, 47907, USA
- Birck Nanotechnology Center, Purdue University, West Lafayette, IN, 47907, USA
| | - Ana Pascual-Garrigos
- Department of Agricultural and Biological Engineering, Purdue University, West Lafayette, IN, 47907, USA
- Birck Nanotechnology Center, Purdue University, West Lafayette, IN, 47907, USA
| | - Suraj Mohan
- Department of Agricultural and Biological Engineering, Purdue University, West Lafayette, IN, 47907, USA
- Birck Nanotechnology Center, Purdue University, West Lafayette, IN, 47907, USA
| | - Sai Venkata Sravan Putikam
- Department of Agricultural and Biological Engineering, Purdue University, West Lafayette, IN, 47907, USA
- Birck Nanotechnology Center, Purdue University, West Lafayette, IN, 47907, USA
| | - Fujr Osman Ibrahim Osman
- Department of Agricultural and Biological Engineering, Purdue University, West Lafayette, IN, 47907, USA
- Birck Nanotechnology Center, Purdue University, West Lafayette, IN, 47907, USA
| | | | | | - Mohit S Verma
- Department of Agricultural and Biological Engineering, Purdue University, West Lafayette, IN, 47907, USA
- Birck Nanotechnology Center, Purdue University, West Lafayette, IN, 47907, USA
- Weldon School of Biomedical Engineering, Purdue University, West Lafayette, IN, 47907, USA
| |
Collapse
|
12
|
Moore KJM, Cahill J, Aidelberg G, Aronoff R, Bektaş A, Bezdan D, Butler DJ, Chittur SV, Codyre M, Federici F, Tanner NA, Tighe SW, True R, Ware SB, Wyllie AL, Afshin EE, Bendesky A, Chang CB, Dela Rosa R, Elhaik E, Erickson D, Goldsborough AS, Grills G, Hadasch K, Hayden A, Her SY, Karl JA, Kim CH, Kriegel AJ, Kunstman T, Landau Z, Land K, Langhorst BW, Lindner AB, Mayer BE, McLaughlin LA, McLaughlin MT, Molloy J, Mozsary C, Nadler JL, D'Silva M, Ng D, O'Connor DH, Ongerth JE, Osuolale O, Pinharanda A, Plenker D, Ranjan R, Rosbash M, Rotem A, Segarra J, Schürer S, Sherrill-Mix S, Solo-Gabriele H, To S, Vogt MC, Yu AD, Mason CE. Loop-Mediated Isothermal Amplification Detection of SARS-CoV-2 and Myriad Other Applications. J Biomol Tech 2021; 32:228-275. [PMID: 35136384 PMCID: PMC8802757 DOI: 10.7171/jbt.21-3203-017] [Citation(s) in RCA: 6] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/23/2022]
Abstract
As the second year of the COVID-19 pandemic begins, it remains clear that a massive increase in the ability to test for SARS-CoV-2 infections in a myriad of settings is critical to controlling the pandemic and to preparing for future outbreaks. The current gold standard for molecular diagnostics is the polymerase chain reaction (PCR), but the extraordinary and unmet demand for testing in a variety of environments means that both complementary and supplementary testing solutions are still needed. This review highlights the role that loop-mediated isothermal amplification (LAMP) has had in filling this global testing need, providing a faster and easier means of testing, and what it can do for future applications, pathogens, and the preparation for future outbreaks. This review describes the current state of the art for research of LAMP-based SARS-CoV-2 testing, as well as its implications for other pathogens and testing. The authors represent the global LAMP (gLAMP) Consortium, an international research collective, which has regularly met to share their experiences on LAMP deployment and best practices; sections are devoted to all aspects of LAMP testing, including preanalytic sample processing, target amplification, and amplicon detection, then the hardware and software required for deployment are discussed, and finally, a summary of the current regulatory landscape is provided. Included as well are a series of first-person accounts of LAMP method development and deployment. The final discussion section provides the reader with a distillation of the most validated testing methods and their paths to implementation. This review also aims to provide practical information and insight for a range of audiences: for a research audience, to help accelerate research through sharing of best practices; for an implementation audience, to help get testing up and running quickly; and for a public health, clinical, and policy audience, to help convey the breadth of the effect that LAMP methods have to offer.
Collapse
Affiliation(s)
- Keith J M Moore
- School of Science and Engineering, Ateneo de Manila University, Quezon City 1108, Philippines
| | | | - Guy Aidelberg
- Université de Paris, INSERM U1284, Center for Research and Interdisciplinarity (CRI), 75006 Paris, France
- Just One Giant Lab, Centre de Recherches Interdisciplinaires (CRI), 75004 Paris, France
| | - Rachel Aronoff
- Just One Giant Lab, Centre de Recherches Interdisciplinaires (CRI), 75004 Paris, France
- Action for Genomic Integrity Through Research! (AGiR!), Lausanne, Switzerland
- Association Hackuarium, Lausanne, Switzerland
| | - Ali Bektaş
- Oakland Genomics Center, Oakland, CA 94609, USA
| | - Daniela Bezdan
- Institute of Medical Genetics and Applied Genomics, University of Tübingen, 72076 Tübingen, Germany
- NGS Competence Center Tübingen (NCCT), University of Tübingen, 72076 Tübingen, Germany
- Poppy Health, Inc, San Francisco, CA 94158, USA
- Institute of Medical Virology and Epidemiology of Viral Diseases, University Hospital, 72076 Tübingen, Germany
| | - Daniel J Butler
- Department of Physiology and Biophysics, Weill Cornell Medicine, New York, NY 10065, USA
- The HRH Prince Alwaleed Bin Talal Bin Abdulaziz Alsaud Institute for Computational Biomedicine, Weill Cornell Medicine, New York, NY 10065, USA
| | - Sridar V Chittur
- Center for Functional Genomics, Department of Biomedical Sciences, School of Public Health, University at Albany, State University of New York, Rensselaer, 12222, USA
| | - Martin Codyre
- GiantLeap Biotechnology Ltd, Wicklow A63 Kv91, Ireland
| | - Fernan Federici
- ANID, Millennium Science Initiative Program, Millennium Institute for Integrative Biology (iBio), Institute for Biological and Medical Engineering, Schools of Engineering, Biology and Medicine, Pontificia Universidad Católica de Chile, Santiago 8331150, Chile
| | | | | | - Randy True
- FloodLAMP Biotechnologies, San Carlos, CA 94070, USA
| | - Sarah B Ware
- Just One Giant Lab, Centre de Recherches Interdisciplinaires (CRI), 75004 Paris, France
- BioBlaze Community Bio Lab, 1800 W Hawthorne Ln, Ste J-1, West Chicago, IL 60185, USA
- Blossom Bio Lab, 1800 W Hawthorne Ln, Ste K-2, West Chicago, IL 60185, USA
| | - Anne L Wyllie
- Department of Epidemiology of Microbial Diseases, Yale School of Public Health, New Haven, CT 06510, USA
| | - Evan E Afshin
- Department of Physiology and Biophysics, Weill Cornell Medicine, New York, NY 10065, USA
- The HRH Prince Alwaleed Bin Talal Bin Abdulaziz Alsaud Institute for Computational Biomedicine, Weill Cornell Medicine, New York, NY 10065, USA
- The WorldQuant Initiative for Quantitative Prediction, Weill Cornell Medicine, New York, NY 10065, USA
| | - Andres Bendesky
- Department of Ecology, Evolution and Environmental Biology, Columbia University, New York, NY 10027, USA
- Zuckerman Mind Brain Behavior Institute, Columbia University, New York, NY 10027, USA
| | - Connie B Chang
- Department of Chemical and Biological Engineering, Montana State University, Bozeman, 59717, USA
- Center for Biofilm Engineering, Montana State University, Bozeman, 59717, USA
| | - Richard Dela Rosa
- School of Science and Engineering, Ateneo de Manila University, Quezon City 1108, Philippines
| | - Eran Elhaik
- Department of Biology, Lund University, Sölvegatan 35, Lund, Sweden
| | - David Erickson
- Sibley School of Mechanical and Aerospace Engineering, Cornell University, Ithaca, NY 14850, USA
| | | | - George Grills
- Department of Microbiology, University of Pennsylvania, Philadelphia, 19104, USA
| | - Kathrin Hadasch
- Université de Paris, INSERM U1284, Center for Research and Interdisciplinarity (CRI), 75006 Paris, France
- Department of Biology, Membrane Biophysics, Technische Universität Darmstadt, 64289 Darmstadt, Germany
- Lab3 eV, Labspace Darmstadt, 64295 Darmstadt, Germany
- IANUS Verein für Friedensorientierte Technikgestaltung eV, 64289 Darmstadt, Germany
| | - Andrew Hayden
- Center for Functional Genomics, Department of Biomedical Sciences, School of Public Health, University at Albany, State University of New York, Rensselaer, 12222, USA
| | | | - Julie A Karl
- Department of Pathology and Laboratory Medicine, School of Medicine and Public Health, University of Wisconsin, Madison, Madison 53705, USA
| | | | | | | | - Zeph Landau
- Department of Computer Science, University of California, Berkeley, Berkeley, 94720, USA
| | - Kevin Land
- Mologic, Centre for Advanced Rapid Diagnostics, (CARD), Bedford Technology Park, Thurleigh MK44 2YA, England
- Department of Electrical, Electronic and Computer Engineering, University of Pretoria, 0028 Pretoria, South Africa
| | | | - Ariel B Lindner
- Université de Paris, INSERM U1284, Center for Research and Interdisciplinarity (CRI), 75006 Paris, France
| | - Benjamin E Mayer
- Department of Biology, Membrane Biophysics, Technische Universität Darmstadt, 64289 Darmstadt, Germany
- Lab3 eV, Labspace Darmstadt, 64295 Darmstadt, Germany
| | | | - Matthew T McLaughlin
- Department of Pathology and Laboratory Medicine, School of Medicine and Public Health, University of Wisconsin, Madison, Madison 53705, USA
| | - Jenny Molloy
- Department of Chemical Engineering and Biotechnology, University of Cambridge, Cambridge CB3 0AS, England
| | - Christopher Mozsary
- Department of Physiology and Biophysics, Weill Cornell Medicine, New York, NY 10065, USA
- The HRH Prince Alwaleed Bin Talal Bin Abdulaziz Alsaud Institute for Computational Biomedicine, Weill Cornell Medicine, New York, NY 10065, USA
| | - Jerry L Nadler
- Department of Pharmacology, New York Medical College, Valhalla, 10595, USA
| | - Melinee D'Silva
- Department of Pharmacology, New York Medical College, Valhalla, 10595, USA
| | - David Ng
- Zuckerman Mind Brain Behavior Institute, Columbia University, New York, NY 10027, USA
| | - David H O'Connor
- Department of Pathology and Laboratory Medicine, School of Medicine and Public Health, University of Wisconsin, Madison, Madison 53705, USA
| | - Jerry E Ongerth
- University of Wollongong, Environmental Engineering, Wollongong NSW 2522, Australia
| | - Olayinka Osuolale
- Applied Environmental Metagenomics and Infectious Diseases Research (AEMIDR), Department of Biological Sciences, Elizade University, Ilara Mokin, Nigeria
| | - Ana Pinharanda
- Department of Biological Sciences, Columbia University, New York, NY 10027, USA
| | - Dennis Plenker
- Cold Spring Harbor Laboratory, Cold Spring Harbor, NY 11724, USA
| | - Ravi Ranjan
- Genomics Resource Laboratory, Institute for Applied Life Sciences, University of Massachusetts, Amherst, 01003, USA
| | - Michael Rosbash
- Howard Hughes Medical Institute and Department of Biology, Brandeis University, Waltham, MA 02453, USA
| | | | | | | | - Scott Sherrill-Mix
- Department of Microbiology, University of Pennsylvania, Philadelphia, 19104, USA
| | | | - Shaina To
- School of Science and Engineering, Ateneo de Manila University, Quezon City 1108, Philippines
| | - Merly C Vogt
- Department of Biological Sciences, Columbia University, New York, NY 10027, USA
| | - Albert D Yu
- Howard Hughes Medical Institute and Department of Biology, Brandeis University, Waltham, MA 02453, USA
| | - Christopher E Mason
- Department of Physiology and Biophysics, Weill Cornell Medicine, New York, NY 10065, USA
- The HRH Prince Alwaleed Bin Talal Bin Abdulaziz Alsaud Institute for Computational Biomedicine, Weill Cornell Medicine, New York, NY 10065, USA
- The WorldQuant Initiative for Quantitative Prediction, Weill Cornell Medicine, New York, NY 10065, USA
- The Feil Family Brain and Mind Research Institute, Weill Cornell Medicine, New York, NY 10065, USA
| |
Collapse
|
13
|
Bektaş A, Covington MF, Aidelberg G, Arce A, Matute T, Núñez I, Walsh J, Boutboul D, Delaugerre C, Lindner AB, Federici F, Jayaprakash AD. Accessible LAMP-Enabled Rapid Test (ALERT) for Detecting SARS-CoV-2. Viruses 2021; 13:742. [PMID: 33922716 PMCID: PMC8146324 DOI: 10.3390/v13050742] [Citation(s) in RCA: 15] [Impact Index Per Article: 3.8] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/14/2021] [Revised: 04/08/2021] [Accepted: 04/15/2021] [Indexed: 01/07/2023] Open
Abstract
The coronavirus disease 2019 (COVID-19) pandemic has highlighted bottlenecks in large-scale, frequent testing of populations for infections. Polymerase chain reaction (PCR)-based diagnostic tests are expensive, reliant on centralized labs, can take days to deliver results, and are prone to backlogs and supply shortages. Antigen tests that bind and detect the surface proteins of a virus are rapid and scalable but suffer from high false negative rates. To address this problem, an inexpensive, simple, and robust 60-minute do-it-yourself (DIY) workflow to detect viral RNA from nasal swabs or saliva with high sensitivity (0.1 to 2 viral particles/μL) and specificity (>97% true negative rate) utilizing reverse transcription loop-mediated isothermal amplification (RT-LAMP) was developed. ALERT (Accessible LAMP-Enabled Rapid Test) incorporates the following features: (1) increased shelf-life and ambient temperature storage, compared to liquid reaction mixes, by using wax layers to isolate enzymes from other reagents; (2) improved specificity compared to other LAMP end-point reporting methods, by using sequence-specific QUASR (quenching of unincorporated amplification signal reporters); (3) increased sensitivity, compared to methods without purification through use of a magnetic wand to enable pipette-free concentration of sample RNA and cell debris removal; (4) quality control with a nasopharyngeal-specific mRNA target; and (5) co-detection of other respiratory viruses, such as influenza B, by multiplexing QUASR-modified RT-LAMP primer sets. The flexible nature of the ALERT workflow allows easy, at-home and point-of-care testing for individuals and higher-throughput processing for labs and hospitals. With minimal effort, severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2)-specific primer sets can be swapped out for other targets to repurpose ALERT to detect other viruses, microorganisms, or nucleic acid-based markers.
Collapse
Affiliation(s)
- Ali Bektaş
- Oakland Genomics Center, 355 30th Street, Oakland, CA 94609, USA; (M.F.C.)
| | - Michael F. Covington
- Oakland Genomics Center, 355 30th Street, Oakland, CA 94609, USA; (M.F.C.)
- Amaryllis Nucleics, 355 30th Street, Oakland, CA 94609, USA
| | - Guy Aidelberg
- Center for Research and Interdisciplinarity (CRI), Université de Paris, INSERM U1284, F-75006 Paris, France; (G.A.); (A.B.L.)
| | - Anibal Arce
- Institute for Biological and Medical Engineering, Schools of Engineering, Biology and Medicine, Pontificia Universidad Católica de Chile, Santiago 7820244, Chile; (A.A.); (T.M.); (I.N.); (F.F.)
- FONDAP Center for Genome Regulation, ANID–Millennium Science Initiative Program–Millennium Institute for Integrative Biology (iBIO), Santiago 8331150, Chile
| | - Tamara Matute
- Institute for Biological and Medical Engineering, Schools of Engineering, Biology and Medicine, Pontificia Universidad Católica de Chile, Santiago 7820244, Chile; (A.A.); (T.M.); (I.N.); (F.F.)
- FONDAP Center for Genome Regulation, ANID–Millennium Science Initiative Program–Millennium Institute for Integrative Biology (iBIO), Santiago 8331150, Chile
| | - Isaac Núñez
- Institute for Biological and Medical Engineering, Schools of Engineering, Biology and Medicine, Pontificia Universidad Católica de Chile, Santiago 7820244, Chile; (A.A.); (T.M.); (I.N.); (F.F.)
- FONDAP Center for Genome Regulation, ANID–Millennium Science Initiative Program–Millennium Institute for Integrative Biology (iBIO), Santiago 8331150, Chile
| | - Julia Walsh
- School of Public Health, University of California Berkeley, Berkeley, CA 94720, USA;
| | - David Boutboul
- Clinical Immunology Department, U976 HIPI, Hôpital Saint Louis, Université de Paris, F-75006 Paris, France; (D.B.); (C.D.)
| | - Constance Delaugerre
- Clinical Immunology Department, U976 HIPI, Hôpital Saint Louis, Université de Paris, F-75006 Paris, France; (D.B.); (C.D.)
| | - Ariel B. Lindner
- Center for Research and Interdisciplinarity (CRI), Université de Paris, INSERM U1284, F-75006 Paris, France; (G.A.); (A.B.L.)
| | - Fernán Federici
- Institute for Biological and Medical Engineering, Schools of Engineering, Biology and Medicine, Pontificia Universidad Católica de Chile, Santiago 7820244, Chile; (A.A.); (T.M.); (I.N.); (F.F.)
- FONDAP Center for Genome Regulation, ANID–Millennium Science Initiative Program–Millennium Institute for Integrative Biology (iBIO), Santiago 8331150, Chile
| | - Anitha D. Jayaprakash
- Oakland Genomics Center, 355 30th Street, Oakland, CA 94609, USA; (M.F.C.)
- Girihlet Inc., 355 30th Street, Oakland, CA 94609, USA
| |
Collapse
|