1
|
Choi H. Design of Preamplifier for Ultrasound Transducers. SENSORS (BASEL, SWITZERLAND) 2024; 24:786. [PMID: 38339502 PMCID: PMC10856992 DOI: 10.3390/s24030786] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 12/01/2023] [Revised: 12/31/2023] [Accepted: 01/12/2024] [Indexed: 02/12/2024]
Abstract
In diagnostic ultrasound imaging applications, preamplifiers are used as first-stage analog front-end amplifiers for ultrasound transducers because they can amplify weak acoustic signals generated directly by ultrasound transducers. For emerging diagnostic ultrasound imaging applications, different types of preamplifiers with specific design parameters and circuit topologies have been developed, depending on the types of the ultrasound transducer. In particular, the design parameters of the preamplifier, such as the gain, bandwidth, input- or output-referred noise components, and power consumption, have a tradeoff relationship. Guidelines on the detailed design concept, design parameters, and specific circuit design techniques of the preamplifier used for ultrasound transducers are outlined in this paper, aiming to help circuit designers and academic researchers optimize the performance of ultrasound transducers used in the diagnostic ultrasound imaging applications for research directions.
Collapse
Affiliation(s)
- Hojong Choi
- Department of Electronic Engineering, Gachon University, 1342 Seongnam-daero, Sujeong-gu, Seongnam 13120, Republic of Korea
| |
Collapse
|
2
|
Heo SP, Choi H, Yang YM. Novel stability approach using Routh-Hurwitz criterion for brain computer interface applications. Technol Health Care 2024; 32:17-25. [PMID: 38669494 PMCID: PMC11191471 DOI: 10.3233/thc-248002] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 04/28/2024]
Abstract
BACKGROUND The stability criterion approach is very important for estimating precise behavior before or after fabricating brain computer interface system applications. OBJECTIVE A novel approach using the Routh-Hurwitz standard criterion method is proposed to easily determine and analyze the stability of brain computer interface system applications. Using this developed approach, we were able to easily test the stability of technical issue using simple programmed codes before or after brain computer interfaces fabrication applications. METHODS Using a MATLAB simulation program package, we are able to provide two different special case examples such as a first zero element and a row of zeros to verify the capability of our proposed Routh-Hurwitz method. RESULTS The MATLAB simulation program provided efficient Routh-Hurwitz standard criterion results by differentiating the highest coefficients of the s and a. CONCLUSION This technical paper explains how to use our proposed new Routh-Hurwitz standard condition to simply ascertain and determine the brain computer interface system stability without customized commercial simulation tools.
Collapse
Affiliation(s)
- Sung-Phil Heo
- Department of Information and Telecommunication Engineering, Gangneung-Wonju National University, Wonju, Korea
| | - Hojong Choi
- Department of Electronic Engineering, Gachon University, Seongnam, Korea
| | - Yeon-Mo Yang
- School of Electronic Engineering, Kumoh National Institute of Technology, Gumi, Korea
| |
Collapse
|
3
|
Choi H. Power Amplifier Design for Ultrasound Applications. MICROMACHINES 2023; 14:1342. [PMID: 37512653 PMCID: PMC10383379 DOI: 10.3390/mi14071342] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 05/16/2023] [Revised: 06/19/2023] [Accepted: 06/26/2023] [Indexed: 07/30/2023]
Abstract
A design analysis of the power amplifiers developed for ultrasound applications was conducted because ultrasound applications require different types of power amplifiers, which are one of the most critical electronic components in ultrasound systems. To generate acoustic signals using transducers, which are among the most important mechanical devices in ultrasound systems, an appropriate output voltage, current, or power signal must be produced by a power amplifier. Therefore, an appropriate design analysis of the power amplifier must be conducted to obtain the optimal performance from a transducer. In addition, because of new ultrasound research trends, such as ultrasound systems with other imaging modalities and wireless ultrasound systems, the selection of an appropriate power amplifier could improve the performance of an ultrasound system with other imaging and therapy modalities. This paper describes the design parameters of a power amplifier, including the gain, bandwidth, harmonic distortion, and efficiency. Each power amplifier has specific applications and limitations. Therefore, this review will assist design engineers and ultrasound researchers who need to develop or use power amplifiers in ultrasound applications.
Collapse
Affiliation(s)
- Hojong Choi
- Department of Electronic Engineering, Gachon University, 1342 Seongnam-daero, Sujeong-gu, Seongnam 13120, Republic of Korea
| |
Collapse
|
4
|
Bloise S, Marcellino A, Sanseviero M, Martucci V, Testa A, Leone R, Del Giudice E, Frasacco B, Gizzone P, Proietti Ciolli C, Ventriglia F, Lubrano R. Point-of-Care Thoracic Ultrasound in Children: New Advances in Pediatric Emergency Setting. Diagnostics (Basel) 2023; 13:1765. [PMID: 37238249 PMCID: PMC10217038 DOI: 10.3390/diagnostics13101765] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/05/2023] [Revised: 05/10/2023] [Accepted: 05/11/2023] [Indexed: 05/28/2023] Open
Abstract
Point-of-care thoracic ultrasound at the patient's bedside has increased significantly recently, especially in pediatric settings. Its low cost, rapidity, simplicity, and repeatability make it a practical examination to guide diagnosis and treatment choices, especially in pediatric emergency departments. The fields of application of this innovative imaging method are many and include primarily the study of lungs but also that of the heart, diaphragm, and vessels. This manuscript aims to describe the most important evidence for using thoracic ultrasound in the pediatric emergency setting.
Collapse
Affiliation(s)
- Silvia Bloise
- UOC di Pediatria e Neonatologia Ospedale Santa Maria Goretti—Polo Pontino, Dipartimento Materno Infantile e di Scienze Urologiche, Sapienza Università di Roma, 00185 Roma, Italy
| | | | | | | | | | | | | | | | | | | | | | | |
Collapse
|
5
|
Choi H. Harmonic-Reduced Bias Circuit for Ultrasound Transducers. SENSORS (BASEL, SWITZERLAND) 2023; 23:s23094438. [PMID: 37177641 PMCID: PMC10181787 DOI: 10.3390/s23094438] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 03/15/2023] [Revised: 04/23/2023] [Accepted: 04/27/2023] [Indexed: 05/15/2023]
Abstract
The gain of class-C power amplifiers is generally lower than that of class-A power amplifiers. Thus, higher-amplitude input voltage signals for class-C power amplifiers are required. However, high-amplitude input signals generate unwanted harmonic signals. Therefore, a novel bias circuit was proposed to suppress the harmonic signals generated by class-C power amplifiers, which improves the output voltage amplitudes. To verify the proposed idea, the input harmonic signals when using a harmonic-reduced bias circuit (-61.31 dB, -89.092 dB, -90.53 dB, and -90.32 dB) were measured and were found to be much lower than those when using the voltage divider bias circuit (-57.19 dB, -73.49 dB, -70.97 dB, and -73.61 dB) at 25 MHz, 50 MHz, 75 MHz, and 100 MHz, respectively. To further validate the proposed idea, the pulse-echo measurements were compared using the bias circuits. The peak-to-peak echo amplitude and bandwidth of the piezoelectric transducer, measured when using a harmonic-reduced bias circuit (27.07 mV and 37.19%), were higher than those achieved with a voltage divider circuit (18.55 mV and 22.71%). Therefore, the proposed scheme may be useful for ultrasound instruments with low sensitivity.
Collapse
Affiliation(s)
- Hojong Choi
- Department of Electronic Engineering, Gachon University, 1342 Seongnam-daero, Sujeong-gu, Seongnam 13120, Republic of Korea
| |
Collapse
|
6
|
Choi H. An Inverse Class-E Power Amplifier for Ultrasound Transducer. SENSORS (BASEL, SWITZERLAND) 2023; 23:3466. [PMID: 37050526 PMCID: PMC10098776 DOI: 10.3390/s23073466] [Citation(s) in RCA: 1] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 02/17/2023] [Revised: 03/23/2023] [Accepted: 03/24/2023] [Indexed: 05/27/2023]
Abstract
An inverse Class-E power amplifier was designed for an ultrasound transducer. The proposed inverse Class-E power amplifier can be useful because of the low series inductance values used in the output matching network that helps to reduce signal distortions. Therefore, a newly designed Class-E power amplifier can obtain a proper echo signal quality. The measured output voltage, voltage gain, voltage gain difference, and power efficiency were 50.1 V, 22.871 dB, 0.932 dB, and 55.342%, respectively. This low voltage difference and relatively high efficiency could verify the capability of the ultrasound transducer. The pulse-echo response experiment using an ultrasound transducer was performed to verify the capability of the proposed inverse Class-E power amplifier. The obtained echo signal amplitude and pulse width were 6.01 mVp-p and 0.81 μs, respectively. The -6 dB bandwidth and center frequencies of the echo signal were 27.25 and 9.82 MHz, respectively. Consequently, the designed Class-E power amplifier did not significantly alter the performance of the center frequency of the ultrasound transducer; therefore, it could be employed particularly in certain ultrasound applications that require high linearity and reasonable power efficiency.
Collapse
Affiliation(s)
- Hojong Choi
- Department of Electronic Engineering, Gachon University, Seongnam-daero 1342, Sujeong-gu, Seongnam 13120, Gyeonggi-do, Republic of Korea
| |
Collapse
|
7
|
Zhang Y, Miao B, Wang G, Zhou H, Zhang S, Hu Y, Wu J, Yu X, Li J. ScAlN Film-Based Piezoelectric Micromechanical Ultrasonic Transducers with Dual-Ring Structure for Distance Sensing. MICROMACHINES 2023; 14:516. [PMID: 36984923 PMCID: PMC10051667 DOI: 10.3390/mi14030516] [Citation(s) in RCA: 1] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 01/29/2023] [Revised: 02/19/2023] [Accepted: 02/21/2023] [Indexed: 06/18/2023]
Abstract
Piezoelectric micromechanical ultrasonic transducers (pMUTs) are new types of distance sensors with great potential for applications in automotive, unmanned aerial vehicle, robotics, and smart homes. However, previously reported pMUTs are limited by a short sensing distance due to lower output sound pressure. In this work, a pMUT with a special dual-ring structure based on scandium-doped aluminum nitride (ScAlN) is proposed. The combination of a dual-ring structure with pinned boundary conditions and a high piezoelectric performance ScAlN film allows the pMUT to achieve a large dynamic displacement of 2.87 μm/V and a high electromechanical coupling coefficient (kt2) of 8.92%. The results of ranging experiments show that a single pMUT achieves a distance sensing of 6 m at a resonant frequency of 91 kHz, the farthest distance sensing registered to date. This pMUT provides surprisingly fertile ground for various distance sensing applications.
Collapse
Affiliation(s)
- Yuchao Zhang
- Suzhou Institute of Nano-Tech and Nano-Bionics, Chinese Academy of Sciences, Suzhou 215123, China
- Key Laboratory of Multifunctional Nanomaterials and Smart Systems, Chinese Academy of Sciences, Suzhou 215123, China
- School of Electrical and Mechanical Engineering, Changchun University of Science and Technology, Changchun 130022, China
| | - Bin Miao
- Suzhou Institute of Nano-Tech and Nano-Bionics, Chinese Academy of Sciences, Suzhou 215123, China
- Key Laboratory of Multifunctional Nanomaterials and Smart Systems, Chinese Academy of Sciences, Suzhou 215123, China
| | - Guanghua Wang
- School of Electrical and Mechanical Engineering, Changchun University of Science and Technology, Changchun 130022, China
| | - Hongyu Zhou
- School of Electrical and Mechanical Engineering, Changchun University of Science and Technology, Changchun 130022, China
| | - Shiqin Zhang
- School of Electrical and Mechanical Engineering, Changchun University of Science and Technology, Changchun 130022, China
| | - Yimin Hu
- Suzhou Institute of Nano-Tech and Nano-Bionics, Chinese Academy of Sciences, Suzhou 215123, China
- Key Laboratory of Multifunctional Nanomaterials and Smart Systems, Chinese Academy of Sciences, Suzhou 215123, China
| | - Junfeng Wu
- School of Aeronautics, Nanjing University of Aeronautics and Astronautics, Nanjing 211106, China
| | - Xuechao Yu
- Suzhou Institute of Nano-Tech and Nano-Bionics, Chinese Academy of Sciences, Suzhou 215123, China
- Key Laboratory of Multifunctional Nanomaterials and Smart Systems, Chinese Academy of Sciences, Suzhou 215123, China
| | - Jiadong Li
- Suzhou Institute of Nano-Tech and Nano-Bionics, Chinese Academy of Sciences, Suzhou 215123, China
- Key Laboratory of Multifunctional Nanomaterials and Smart Systems, Chinese Academy of Sciences, Suzhou 215123, China
- School of Electrical and Mechanical Engineering, Changchun University of Science and Technology, Changchun 130022, China
| |
Collapse
|
8
|
Choi H. A Doherty Power Amplifier for Ultrasound Instrumentation. SENSORS (BASEL, SWITZERLAND) 2023; 23:s23052406. [PMID: 36904610 PMCID: PMC10007245 DOI: 10.3390/s23052406] [Citation(s) in RCA: 5] [Impact Index Per Article: 5.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 12/15/2022] [Revised: 01/29/2023] [Accepted: 01/30/2023] [Indexed: 05/27/2023]
Abstract
The ultrasound instrumentation uses linear power amplifiers with low power efficiency, generating unwanted heat and resulting in the deterioration of the echo signal quality of measured targets. Therefore, this study aims to develop a power amplifier scheme to increase power efficiency while maintaining appropriate echo signal quality. In communication systems, the Doherty power amplifier has shown relatively good power efficiency while producing high signal distortion. The same design scheme cannot be directly applied to ultrasound instrumentation. Therefore, the Doherty power amplifier needs to be re-designed. To verify the feasibility of the instrumentation, a Doherty power amplifier was designed to obtain high power efficiency. The measured gain, output 1-dB compression point, and power-added efficiency of the designed Doherty power amplifier were 33.71 dB, 35.71 dBm, and 57.24% at 25 MHz, respectively. In addition, the performance of the developed amplifier was measured and tested using the ultrasound transducer through the pulse-echo responses. The output power with 25 MHz, 5-cycle, and 43.06 dBm generated from the Doherty power amplifier was sent through the expander to the focused ultrasound transducer with 25 MHz and 0.5″ diameter. The detected signal was sent via a limiter. Afterwards, the signal was amplified by a 36.8 dB gain preamplifier, and then displayed in the oscilloscope. The measured peak-to-peak amplitude in the pulse-echo response with an ultrasound transducer was 0.9698 V. The data showed a comparable echo signal amplitude. Therefore, the designed Doherty power amplifier can improve the power efficiency used for medical ultrasound instrumentation.
Collapse
Affiliation(s)
- Hojong Choi
- Department of Electronic Engineering, Gachon University, 1342 Seongnam-daero, Sujeong-gu, Seongnam 13120, Gyeonggi-do, Republic of Korea
| |
Collapse
|
9
|
Zhang W, Ma Z, Wang H, Deng J, Li P, Jia Y, Dong Y, Sha H, Yan F, Tu W. Study on automatic ultrasound scanning of lumbar spine and visualization system for path planning in lumbar puncture surgery. MATHEMATICAL BIOSCIENCES AND ENGINEERING : MBE 2023; 20:613-623. [PMID: 36650781 DOI: 10.3934/mbe.2023028] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/17/2023]
Abstract
In lumbar puncture surgery, compared with the conventional methodologies like computed tomography and magnetic resonance imaging, ultrasound imaging offers the advantages of being low cost, no radiation and real-time image generation. However, the use of ultrasound equipment in lumbar puncture involves a cumbersome and time-consuming process for the subjective imaging of the overall structure of the lumbar spine in order to determine the exact puncture point and path. Meanwhile, the robotic arm puncture system has the advantages of high precision, good stability and simple and efficient operation. As a result, robotic-assisted ultrasound scanning is valuable for the assessment of a puncture path in spinal tap surgery. In this pursuit, based on the official URSDK development package for a robot arm and the Transmission Control Protocol/Internet Protocol, the system proposed in the present study involves a program to control the robot arm to clamp down onto an ultrasonic probe to enable automatic scanning and acquisition of images. A three-dimensional reconstruction program based on the visualization toolkit was designed, and a lumbar spine experiment was conducted with this system. A total of 136 two-dimensional ultrasound images were collected in the lumbar spine model experiment by enhancing contrast of and denoising the original ultrasound images, and a linear interpolation algorithm was used to perform the three-dimensional reconstruction of the lumbar spine model. The reconstructed structure was defective, but the location of the spinous process gap was determined with the sagittal and coronal images. The feasibility of the system was verified by the reconstruction results, which can provide a reference for determining the puncture point and path planning in the lumbar puncture surgery.
Collapse
Affiliation(s)
- Wenlu Zhang
- Institute of Biomedical Engineering, Chinese Academy of Medical Sciences & Peking Union Medical College, Tianjin 300192, China
| | - Ziyue Ma
- Institute of Biomedical Engineering, Chinese Academy of Medical Sciences & Peking Union Medical College, Tianjin 300192, China
| | - Hong Wang
- Institute of Biomedical Engineering, Chinese Academy of Medical Sciences & Peking Union Medical College, Tianjin 300192, China
| | - Juan Deng
- Institute of Biomedical Engineering, Chinese Academy of Medical Sciences & Peking Union Medical College, Tianjin 300192, China
| | - Pengfei Li
- Institute of Biomedical Engineering, Chinese Academy of Medical Sciences & Peking Union Medical College, Tianjin 300192, China
| | - Yu Jia
- Institute of Biomedical Engineering, Chinese Academy of Medical Sciences & Peking Union Medical College, Tianjin 300192, China
| | - Yabin Dong
- Institute of Biomedical Engineering, Chinese Academy of Medical Sciences & Peking Union Medical College, Tianjin 300192, China
| | - Hong Sha
- Institute of Biomedical Engineering, Chinese Academy of Medical Sciences & Peking Union Medical College, Tianjin 300192, China
| | - Feng Yan
- Department of Neurosurgery, Capital Medical University Xuanwu Hospital, Beijing 100053, China
| | - Wenjun Tu
- Institute of Radiation Medicine, Chinese Academy of Medical Sciences & Peking Union Medical College, Tianjin 300192, China
| |
Collapse
|
10
|
Zhang Z, Li J, Peng L, Sun B. Multi-Band Power Amplifier Module with Back-Off Efficiency Improvement using Ultra-Compact 3D Vertical Stack Multi-Chip Package for Cellular Handsets. MICROMACHINES 2022; 13:1976. [PMID: 36422405 PMCID: PMC9698143 DOI: 10.3390/mi13111976] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 10/19/2022] [Revised: 11/07/2022] [Accepted: 11/14/2022] [Indexed: 06/16/2023]
Abstract
A highly integrated multi-mode multi-band (MMMB) power amplifier module (PAM) using hybrid bulk complementary metal oxide semiconductor (CMOS), gallium arsenide (GaAs) heterojunction bipolar transistor (HBT), and silicon-on-insulator (SOI) technologies for low band (LB, 824-915 MHz) and high band (HB, 1710-1980 MHz) is proposed. The hybrid MMMB PAM integrates a bulk CMOS controller die, a GaAs HBT power amplifier (PA) die and a SOI switch die on a six-layer laminate. To simultaneously obtain both highly efficient and highly linear characteristics over a wide range of input power levels, a parallel dual-chain PA strategy has been adopted to provide vary bias current and gain for low-power mode (LPM) and high-power mode (HPM) operation. Additionally, a broadband two-section low-pass output matching network design based on the suppression of high-order harmonics is proposed for enhanced efficiency and linearity. In order to achieve further miniaturization, a three-dimensional (3D) die stack multi-chip module (MCM) packaging structure, where the presented CMOS controller die is stacked vertically on the GaAs HBT PA die, is implemented. The measurement results show that the fabricated MMMB PAM achieves 26.1-27 dB of power gains and 38-38.4% of PAEs at an output power (Pout) of 28 dBm in the HPM, and 20.4-20.9 dB of power gains and 12.4-13.8% of PAEs at Pout of 17 dBm in the LPM over LB. For HB, power gains of 24.3-26.7 dB while maintaining PAEs of 38.2-39.9% at Pout of 28 dBm, and power gains of 15.9-17.5 dB while maintaining PAEs of 12.3-12.8% at Pout of 17 dBm are realized in the HPM and LPM, respectively. The fabricated PAM covering five frequency bands and operating at two power modes only occupies a 5 × 3.5 mm2 area. To the best of the authors' knowledge, this work is the first demonstration of a MMMB PAM adopting an ultra-compact 3D vertical stack MCM package with favorable RF performance.
Collapse
Affiliation(s)
- Zhihao Zhang
- School of Integrated Circuits, Guangdong University of Technology, Guangzhou 510006, China
| | - Jing Li
- Institute of Public Policy, South China University of Technology, Guangzhou 510610, China
| | - Lin Peng
- School of Integrated Circuits, Guangdong University of Technology, Guangzhou 510006, China
| | - Bo Sun
- School of Integrated Circuits, Guangdong University of Technology, Guangzhou 510006, China
| |
Collapse
|
11
|
An ultrasound-induced wireless power supply based on AlN piezoelectric micromachined ultrasonic transducers. Sci Rep 2022; 12:16174. [PMID: 36171230 PMCID: PMC9519918 DOI: 10.1038/s41598-022-19693-5] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/28/2022] [Accepted: 09/02/2022] [Indexed: 11/09/2022] Open
Abstract
Wireless power transfer is one of the enabling technologies for powering implantable biomedical devices. Biocompatibility and CMOS compatibility of wireless power transfer devices are highly desired due to safety and footprint concerns. Toward implantable applications, this paper presents an ultrasound-induced wireless power supply based on AlN piezoelectric micromachined ultrasonic transducer (PMUT). The wireless power supply integrates wireless power transfer, power management and energy storage functions. The PMUT array is used as a passive wireless power receiver, followed by electrical impedance matching networks and a voltage multiplier for efficient power transmission and rectification. The output power intensity of the wireless receiver reaches 7.36 μW/mm2 with an incident ultrasound power below the FDA safety limit. The output power of the wireless power supply reaches 18.8 μW and a 100-μF capacitor is fully charged to 3.19 V after power management, which are sufficient to power many low-power implantable biomedical devices such as for neural electrical stimulation, biosensors and intrabody communication applications. The wireless power supply is implemented in a PCB with a diameter of 1 cm. With biocompatibility and CMOS compatibility of AlN thin film compared to commonly used PZT, the proposed solution paves the way for safer and ultraminiaturized wireless power supplies with further development incorporating all the functions on a monolithic chip in the future.
Collapse
|
12
|
Liu ZY, Zhang P, Zhang BX, Wang W. Multi Spherical Wave Imaging Method Based on Ultrasonic Array. SENSORS (BASEL, SWITZERLAND) 2022; 22:6800. [PMID: 36146155 PMCID: PMC9504764 DOI: 10.3390/s22186800] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 07/28/2022] [Revised: 09/04/2022] [Accepted: 09/05/2022] [Indexed: 06/16/2023]
Abstract
The imaging range of traditional plane wave imaging is usually limited by the directivity of the plane wave. In this paper, a multi spherical wave imaging method based on an ultrasonic array is proposed, which radiates both compression and shear waves in a solid medium to form the multi spherical wave. Firstly, excitation characteristics of the multi spherical wave are analyzed theoretically and the calculation method of echo delay of multi spherical wave imaging is derived. Multi spherical wave imaging is compared with conventional ultrasonic plane wave imaging by designing experiments. Compared with ultrasonic plane wave imaging, multi spherical wave imaging is not limited to the size of the transducer and can greatly improve the detection range. In addition, compared with the multi plane wave imaging method, the multi spherical wave imaging algorithm is relatively simple, fast, and has high application value.
Collapse
Affiliation(s)
- Zhi-Ying Liu
- Key Laboratory of Acoustics, Institute of Acoustics, Chinese Academy of Sciences, Beijing 100190, China
- University of Chinese Academy of Sciences, Beijing 100049, China
| | - Ping Zhang
- Key Laboratory of Acoustics, Institute of Acoustics, Chinese Academy of Sciences, Beijing 100190, China
- Key Laboratory of Nondestructive Testing, Ministry of Education, Nanchang Hangkong University, Nanchang 330063, China
| | - Bi-Xing Zhang
- Key Laboratory of Acoustics, Institute of Acoustics, Chinese Academy of Sciences, Beijing 100190, China
- University of Chinese Academy of Sciences, Beijing 100049, China
| | - Wen Wang
- Key Laboratory of Acoustics, Institute of Acoustics, Chinese Academy of Sciences, Beijing 100190, China
- University of Chinese Academy of Sciences, Beijing 100049, China
| |
Collapse
|
13
|
Cheng C, Peters T, Dangi A, Agrawal S, Chen H, Kothapalli SR, Trolier-McKinstry S. Improving PMUT Receive Sensitivity via DC Bias and Piezoelectric Composition. SENSORS (BASEL, SWITZERLAND) 2022; 22:5614. [PMID: 35957175 PMCID: PMC9370952 DOI: 10.3390/s22155614] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 06/28/2022] [Revised: 07/23/2022] [Accepted: 07/25/2022] [Indexed: 06/15/2023]
Abstract
The receive sensitivity of lead zirconate titanate (PZT) piezoelectric micromachined ultrasound transducers (PMUTs) was improved by applying a DC bias during operation. The PMUT receive sensitivity is governed by the voltage piezoelectric coefficient, h31,f. With applied DC biases (up to 15 V) on a 2 μm PbZr0.52Ti0.48O3 film, e31,f increased 1.6 times, permittivity decreased by a factor of 0.6, and the voltage coefficient increased by ~2.5 times. For released PMUT devices, the ultrasound receive sensitivity improved by 2.5 times and the photoacoustic signal improved 1.9 times with 15 V applied DC bias. B-mode photoacoustic imaging experiments showed that with DC bias, the PMUT received clearer photoacoustic signals from pencil leads at 4.3 cm, compared to 3.7 cm without DC bias.
Collapse
Affiliation(s)
- Christopher Cheng
- Department of Materials Science and Engineering, Penn State University, University Park, PA 16802, USA; (C.C.); (T.P.)
| | - Travis Peters
- Department of Materials Science and Engineering, Penn State University, University Park, PA 16802, USA; (C.C.); (T.P.)
| | - Ajay Dangi
- Department of Biomedical Engineering, Penn State University, University Park, PA 16802, USA; (A.D.); (S.A.); (H.C.); (S.-R.K.)
| | - Sumit Agrawal
- Department of Biomedical Engineering, Penn State University, University Park, PA 16802, USA; (A.D.); (S.A.); (H.C.); (S.-R.K.)
| | - Haoyang Chen
- Department of Biomedical Engineering, Penn State University, University Park, PA 16802, USA; (A.D.); (S.A.); (H.C.); (S.-R.K.)
| | - Sri-Rajasekhar Kothapalli
- Department of Biomedical Engineering, Penn State University, University Park, PA 16802, USA; (A.D.); (S.A.); (H.C.); (S.-R.K.)
| | - Susan Trolier-McKinstry
- Department of Materials Science and Engineering and Materials Research Institute, Penn State University, University Park, PA 16802, USA
| |
Collapse
|
14
|
A Microwave Imaging Procedure for Lung Lesion Detection: Preliminary Results on Multilayer Phantoms. ELECTRONICS 2022. [DOI: 10.3390/electronics11132105] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 02/06/2023]
Abstract
In this work, a feasibility study for lung lesion detection through microwave imaging based on Huygens’ principle (HP) has been performed using multilayer oval shaped phantoms mimicking human torso having a cylindrically shaped inclusion simulating lung lesion. First, validation of the proposed imaging method has been performed through phantom experiments using a dedicated realistic human torso model inside an anechoic chamber, employing a frequency range of 1–5 GHz. Subsequently, the miniaturized torso phantom validation (using both single and double inclusion scenarios) has been accomplished using a microwave imaging (MWI) device, which operates in free space using two antennas in multi-bistatic configuration. The identification of the target’s presence in the lung layer has been achieved on the obtained images after applying both of the following artifact removal procedures: (i) the “rotation subtraction” method using two adjacent transmitting antenna positions, and (ii) the “ideal” artifact removal procedure utilizing the difference between received signals from unhealthy and healthy scenarios. In addition, a quantitative analysis of the obtained images was executed based on the definition of signal to clutter ratio (SCR). The obtained results verify that HP can be utilized successfully to discover the presence and location of the inclusion in the lung-mimicking phantom, achieving an SCR of 9.88 dB.
Collapse
|
15
|
Using Zone Impedance Matching Technique to Improve the Power Transfer Capability of an Inductive Charging System over a Long Distance. ELECTRONICS 2022. [DOI: 10.3390/electronics11131982] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 11/16/2022]
Abstract
In many outdoor inductive charging applications, the objects can move quickly, and the environment can change unpredictably. It is therefore difficult to design a fast controller that tracks the change in mutual coupling between the transmitter and receiver. The diminished power delivery to the objects either leads to incomplete charging or prolongs the charging time. In this paper, the concept of a zone impedance matching technique is proposed. This technique pre-matches the transmitter coil to the desired coupling coefficients. Thus, the power transfer capability of the inductive charger can be maintained at a reasonably high level over a long transmission distance and under a wide receiver misalignment. Based on a three-coil inductive power transfer (IPT) system, the proposed concept is practically implemented with a simple control scheme. The proposed IPT system equips a multi-tap transmitter coil to provide flexibility in selecting different numbers of turns in the transmitter coil. The controller senses the currents of the transmitter coil and the repeater coil to determine the zone of impedance to adapt to the change in mutual coupling of the coils. A mathematical analysis is conducted to formulate the design procedures for the proposed system. Under a wide range of distance and misalignment conditions, practical measurement results verified that the proposed system achieves higher power delivery than an ordinary design.
Collapse
|
16
|
Automatic 3D MRI-Ultrasound Registration for Image Guided Arthroscopy. APPLIED SCIENCES-BASEL 2022. [DOI: 10.3390/app12115488] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 02/01/2023]
Abstract
Registration of partial view intra-operative ultrasound (US) to pre-operative MRI is an essential step in image-guided minimally invasive surgery. In this paper, we present an automatic, landmark-free 3D multimodal registration of pre-operative MRI to 4D US (high-refresh-rate 3D-US) for enabling guidance in knee arthroscopy. We focus on the problem of initializing registration in the case of partial views. The proposed method utilizes a pre-initialization step of using the automatically segmented structures from both modalities to achieve a global geometric initialization. This is followed by computing distance maps of the procured segmentations for registration in the distance space. Following that, the final local refinement between the MRI-US volumes is achieved using the LC2 (Linear correlation of linear combination) metric. The method is evaluated on 11 cases spanning six subjects, with four levels of knee flexion. A best-case error of 1.41 mm and 2.34∘ and an average registration error of 3.45 mm and 7.76∘ is achieved in translation and rotation, respectively. An inter-observer variability study is performed, and a mean difference of 4.41 mm and 7.77∘ is reported. The errors obtained through the developed registration algorithm and inter-observer difference values are found to be comparable. We have shown that the proposed algorithm is simple, robust and allows for the automatic global registration of 3D US and MRI that can enable US based image guidance in minimally invasive procedures.
Collapse
|
17
|
A Wideband High-Efficiency GaN MMIC Power Amplifier for Sub-6-GHz Applications. MICROMACHINES 2022; 13:mi13050793. [PMID: 35630260 PMCID: PMC9145704 DOI: 10.3390/mi13050793] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 05/07/2022] [Revised: 05/14/2022] [Accepted: 05/17/2022] [Indexed: 11/30/2022]
Abstract
The monolithic microwave integrated circuit (MMIC) power amplifiers serve an essential and critical role in RF transmit/receive (T/R) modules of phased array radar systems, mobile communication systems and satellite systems. Over recent years, there has been an increasing requirement to develop wideband high-efficiency MMIC high power amplifiers (HPAs) to accommodate wideband operation and reduce power consumption. This paper presents a wideband high efficiency MMIC HPA for Sub-6-GHz applications using a 0.25-μm gate-length D-mode GaN/SiC high electron mobility transistor (HEMT) process. The amplifier consists of two stages with two HEMT cells for the driver stage and eight HEMT cells for the power stage. To obtain a flat gain while maintaining the wideband characteristic, a gain equalization technique is employed in the inter-stage matching circuit. Meanwhile, a low-loss output matching network is utilized to ensure high efficiency. The fabricated HPA occupies a compact chip area of 14.35 mm2 including testing pads. Over the frequency range of 2–6 GHz, measured results of this HPA show a saturated continuous wave (CW) output power of 44.4–45.2 dBm, a power added efficiency (PAE) of 35.8–51.3%, a small signal gain of 24–25.5 dB, and maximum input and output return losses of 14.5 and 10 dB, respectively.
Collapse
|
18
|
Choi H. Novel dual-resistor-diode limtier circuit structures for high-voltage reliable ultrasound receiver systems. Technol Health Care 2022; 30:513-520. [PMID: 35124625 PMCID: PMC9028643 DOI: 10.3233/thc-228047] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/15/2022]
Abstract
BACKGROUND: The limiters have been used to protect the ultrasound receivers because of the inherent characteristic of the transducers which are required to use the high voltage excitation to obtain the reasonable echo signal amplitudes. OBJECTIVE: Among the variety of the limiters, the performances of discharge voltage degradation from the limiters gradually deteriorate the whole ultrasound systems according to the applied voltages of the ultrasonic transducers. This could cause the ultrasound systems to be unreliable for the long-term operations, resulting in possibly breaking the receiver systems. METHODS: Designed limiters were evaluated with insertion loss, total harmonic distortion, and pulse-echo responses with the ultrasound transducer devices. RESULTS: Designed new dual-resistor-diode limiters exhibited greater and faster suppression of the pulse width (1.15 V and 6.1 μs) for high-voltage signals. CONCLUSIONS: Our proposed dual-resistor-diode limiter could be one of the potential candidates for reliable ultrasound receiver system.
Collapse
|
19
|
Yang J, Chen X, Cai H, Wang Y. Generalized sidelobe canceler beamforming combined with eigenspace-wiener postfilter for medical ultrasound imaging. Technol Health Care 2022; 30:501-512. [PMID: 35124624 PMCID: PMC9028622 DOI: 10.3233/thc-thc228046] [Citation(s) in RCA: 2] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/15/2022]
Abstract
BACKGROUND: The beamforming algorithm is key to the image quality of the medical ultrasound system. The generalized sidelobe canceler (GSC) beamforming can improve the image quality in lateral resolution, but the contrast is not improved correspondingly. OBJECTIVE: In our research, we try to optimize the generalized sidelobe canceler to obtain images that achieve an improvement in both lateral resolution and contrast. METHODS: We put forward a new beamforming algorithm which combines the generalized sidelobe canceler and Eigenspace-Wiener postfilter. According to eigenspace decomposition of the covariance matrix of the received data, the components of the Wiener postfilter can be calculated from the signal matrix and the noise matrix. Then, the adaptive weight vector of GSC is further constrained by the Eigenspace-Wiener postfilter, which make the output energy of the receiving array closer to the desired signal than the conventional GSC output. RESULTS: We compare the new beamforming algorithm with delay-and-sum (DS) beamforming, synthetic aperture (SA) beamforming, and GSC beamforming using the simulated and experimental data sets. The quantitative results show that our method reduces the FWHM by 85.5%, 80.5%, and 38.9% while improving the CR by 123.6%, 47.7%, 84.4% on basis of DS, SA, and GSC beamforming, respectively. CONCLUSIONS: The new beamforming algorithm can obviously improve the imaging quality of medical ultrasound imaging systems in both lateral resolution and contrast.
Collapse
Affiliation(s)
| | - Xiaodong Chen
- Corresponding author: Xiaodong Chen, Key Laboratory of Opto-Electronics Information Technology, Ministry of Education, School of Precision Instrument and Opto-Electronics Engineering, Tianjin University, Tianjin 300072, China. Tel.: +86 22 2740 4535; E-mail:
| | | | | |
Collapse
|
20
|
Ryu S, Ryu J, Choi H. Fisheye lens design for solar-powered mobile ultrasound devices. Technol Health Care 2022; 30:243-250. [PMID: 35124601 PMCID: PMC9028671 DOI: 10.3233/thc-228023] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/15/2022]
Abstract
BACKGROUND: Compared to benchtop ultrasound machines, mobile ultrasound machines require portable batteries when acquiring information regarding human tissues during outdoor activities. OBJECTIVE: A novel fisheye lens type was designed to address the charging issue where it is difficult to constantly track the sun. This method does not require the use of a mechanical motor that constantly tracks the sun to charge the portable batteries. METHODS: To obtain an optical solar power system, the numerical aperture (NA) and field angle must be increased. Therefore, we use the fisheye lens with the largest field angle. RESULTS: The NA of the designed fisheye lens system reaches 0.75, allowing light collection of approximately ± 48∘. Additionally, the efficiency ratio of the central and surrounding areas also satisfies more than 80% at a field angle of 85∘ and more than 70% at field angles of 85∘ to 90∘, respectively. CONCLUSIONS: We designed a novel fisheye lens for solar-powered mobile ultrasound machines used outdoors.
Collapse
Affiliation(s)
- Seonho Ryu
- Department of Optical System Engineering, Kumoh National Institute of Technology, Gumi, Korea
| | - Jaemyung Ryu
- Department of Optical System Engineering, Kumoh National Institute of Technology, Gumi, Korea
| | - Hojong Choi
- Department of Medical IT Convergence Engineering, Kumoh National Institute of Technology, Gumi, Korea
| |
Collapse
|
21
|
Saez-Mingorance B, Mendez-Gomez J, Mauro G, Castillo-Morales E, Pegalajar-Cuellar M, Morales-Santos DP. Air-Writing Character Recognition with Ultrasonic Transceivers. SENSORS 2021; 21:s21206700. [PMID: 34695913 PMCID: PMC8537432 DOI: 10.3390/s21206700] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 09/10/2021] [Revised: 09/24/2021] [Accepted: 09/28/2021] [Indexed: 11/16/2022]
Abstract
The interfaces between users and systems are evolving into a more natural communication, including user gestures as part of the interaction, where air-writing is an emerging application for this purpose. The aim of this work is to propose a new air-writing system based on only one array of ultrasonic transceivers. This track will be obtained based on the pairwise distance of the hand marker with each transceiver. After acquiring the track, different deep learning algorithms, such as long short-term memory (LSTM), convolutional neural networks (CNN), convolutional autoencoder (ConvAutoencoder), and convolutional LSTM have been evaluated for character recognition. It has been shown how these algorithms provide high accuracy, where the best result is extracted from the ConvLSTM, with 99.51% accuracy and 71.01 milliseconds of latency. Real data were used in this work to evaluate the proposed system in a real scenario to demonstrate its high performance regarding data acquisition and classification.
Collapse
Affiliation(s)
- Borja Saez-Mingorance
- Infineon Technologies AG, Am Campeon 1-15, 85579 Neubiberg, Germany; (B.S.-M.); (J.M.-G.); (G.M.)
- Department of Electronic and Computer Technology, University of Granada, Avenida de Fuente Nueva s/n, 18071 Granada, Spain;
| | - Javier Mendez-Gomez
- Infineon Technologies AG, Am Campeon 1-15, 85579 Neubiberg, Germany; (B.S.-M.); (J.M.-G.); (G.M.)
- Department of Electronic and Computer Technology, University of Granada, Avenida de Fuente Nueva s/n, 18071 Granada, Spain;
| | - Gianfranco Mauro
- Infineon Technologies AG, Am Campeon 1-15, 85579 Neubiberg, Germany; (B.S.-M.); (J.M.-G.); (G.M.)
- Department of Electronic and Computer Technology, University of Granada, Avenida de Fuente Nueva s/n, 18071 Granada, Spain;
| | - Encarnacion Castillo-Morales
- Department of Electronic and Computer Technology, University of Granada, Avenida de Fuente Nueva s/n, 18071 Granada, Spain;
| | - Manuel Pegalajar-Cuellar
- Department of Computer Science and Artificial Intelligence, University of Granada, Calle Periodista Daniel Saucedo Aranda s/n, 18071 Granada, Spain;
| | - Diego P. Morales-Santos
- Department of Electronic and Computer Technology, University of Granada, Avenida de Fuente Nueva s/n, 18071 Granada, Spain;
- Correspondence:
| |
Collapse
|
22
|
The Value of Contrast-Enhanced Ultrasound (CEUS) in Differentiating Testicular Masses: A Systematic Review and Meta-Analysis. APPLIED SCIENCES-BASEL 2021. [DOI: 10.3390/app11198990] [Citation(s) in RCA: 18] [Impact Index Per Article: 6.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 12/11/2022]
Abstract
Ultrasound (US) still represents the mainstay of scrotal imaging. However, contrast-enhanced ultrasound (CEUS) is a relatively novel, but increasingly utilized diagnostic modality. In consequence, we performed a systematic review (SR) and pooled meta-analysis to investigate the diagnostic performance of CEUS in the evaluation of testicular masses (TM). A SR up to June 2021 was performed according to the Preferred Reporting Items for Systematic Reviews and Meta-Analyses (PRISMA) statement. The diagnostic performance of CEUS was evaluated basing on two different endpoints: neoplastic vs. non-neoplastic and malignant vs. benign TM. Sensitivity, specificity, positive predictive value (PPV), and negative predictive value (NPV) from eligible studies were pooled and summary receiver operating characteristic (SROC) curves were constructed for each endpoint. Overall, six qualified studies were deemed suitable for this meta-analysis. Diagnostic performance of CEUS showed an accuracy of 0.96 in detecting neoplastic masses (sensitivity of 0.89, PPV of 0.85, specificity of 0.62, and NPV of 0.69) and an accuracy of 0.96 in detecting malignant masses (sensitivity of 0.86, PPV of 0.73, specificity of 0.87, and NPV of 0.91). Taken together, CEUS may represent a promising minimally invasive diagnostic tool for characterization of TM, since it allows clinicians to identify neoplastic lesions and exclude malignant tumor.
Collapse
|
23
|
Pei Y, Zhang G, Zhang Y, Zhang W. Breast Acoustic Parameter Reconstruction Method Based on Capacitive Micromachined Ultrasonic Transducer Array. MICROMACHINES 2021; 12:963. [PMID: 34442585 PMCID: PMC8400655 DOI: 10.3390/mi12080963] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 06/10/2021] [Revised: 08/07/2021] [Accepted: 08/10/2021] [Indexed: 11/17/2022]
Abstract
Ultrasound computed tomography (USCT) systems based on capacitive micromachined ultrasonic transducer (CMUT) arrays have a wide range of application prospects. For this paper, a high-precision image reconstruction method based on the propagation path of ultrasound in breast tissue are designed for the CMUT ring array; that is, time-reversal algorithms and FBP algorithms are respectively used to reconstruct sound speed distribution and acoustic attenuation distribution. The feasibility of this reconstruction method is verified by numerical simulation and breast model experiments. According to reconstruction results, sound speed distribution reconstruction deviation can be reduced by 53.15% through a time-reversal algorithm based on wave propagation theory. The attenuation coefficient distribution reconstruction deviation can be reduced by 61.53% through FBP based on ray propagation theory. The research results in this paper will provide key technological support for a new generation of ultrasound computed tomography systems.
Collapse
Affiliation(s)
| | - Guojun Zhang
- State Key Laboratory of Dynamic Testing Technology, North University of China, Taiyuan 030051, China; (Y.P.); (Y.Z.); (W.Z.)
| | | | | |
Collapse
|
24
|
Patil S, Alkahtani A, Bhandi S, Mashyakhy M, Alvarez M, Alroomy R, Hendi A, Varadarajan S, Reda R, Raj AT, Testarelli L. Ultrasound Imaging versus Radiographs in Differentiating Periapical Lesions: A Systematic Review. Diagnostics (Basel) 2021; 11:1208. [PMID: 34359291 PMCID: PMC8303698 DOI: 10.3390/diagnostics11071208] [Citation(s) in RCA: 17] [Impact Index Per Article: 5.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/31/2021] [Revised: 06/29/2021] [Accepted: 07/02/2021] [Indexed: 12/25/2022] Open
Abstract
BACKGROUND Ultrasonography is a non-invasive method of diagnosing periapical lesions while radiologic methods are more common. Periapical lesions due to endodontic infection are one of the most common causes of periapical radiolucency that need to be distinguished to help determine the course of treatment. This review aimed to examine the accuracy of ultrasound and compare it to radiographs in distinguishing these lesions in vivo. METHODS This review process followed the PRISMA guidelines. A literature search of databases (PubMed, Scopus, Embase, and Web of Science) was conducted without any restrictions on time. Articles available in English were included. The selection was done according to the inclusion and exclusion criteria. The QUADAS-2 tool was used to assess the quality of the studies. RESULTS The search provided a total of 87 articles, out of which, five were selected for the final review. In all the studies, ultrasound had higher accuracy in distinguishing periapical lesions. All the studies indicated a risk of bias, especially in patient selection. CONCLUSION Within limitations, the study indicates that ultrasound is a better diagnostic tool to distinguish periapical lesions compared to radiographs but further studies with well-designed, rigorous protocols and low risk of bias are needed to provide stronger evidence.
Collapse
Affiliation(s)
- Shankargouda Patil
- Department of Maxillofacial Surgery and Diagnostic Sciences, Division of Oral Pathology, College of Dentistry, Jazan University, Jazan 45142, Saudi Arabia;
| | - Ahmed Alkahtani
- Department of Restorative Dental Sciences, College of Dentistry, King Saud University, Riyadh 11451, Saudi Arabia;
| | - Shilpa Bhandi
- Department of Restorative Dental Sciences, College of Dentistry, Jazan University, Jazan 45142, Saudi Arabia; (S.B.); (M.M.)
| | - Mohammed Mashyakhy
- Department of Restorative Dental Sciences, College of Dentistry, Jazan University, Jazan 45142, Saudi Arabia; (S.B.); (M.M.)
| | - Mario Alvarez
- Division of Endodontics and Orthodontics, University of Southern California, Los Angeles, CA 90007, USA;
| | - Riyadh Alroomy
- Department of Restorative Dental Sciences, College of Dentistry, Majmaah University, AlMajmaah 11952, Saudi Arabia;
| | - Ali Hendi
- Department of Radiology, Faculty of Medicine, Jazan University, Jazan 45142, Saudi Arabia;
| | - Saranya Varadarajan
- Department of Oral Pathology and Microbiology, Sri Venkateswara Dental College and Hospital, Chennai 600130, India; (S.V.); (A.T.R.)
| | - Rodolfo Reda
- Department of Oral and Maxillofacial Sciences, Sapienza University, University of Rome, 00161 Rome, Italy;
| | - A. Thirumal Raj
- Department of Oral Pathology and Microbiology, Sri Venkateswara Dental College and Hospital, Chennai 600130, India; (S.V.); (A.T.R.)
| | - Luca Testarelli
- Department of Oral and Maxillofacial Sciences, Sapienza University, University of Rome, 00161 Rome, Italy;
| |
Collapse
|
25
|
A Novel Analog Circuit Soft Fault Diagnosis Method Based on Convolutional Neural Network and Backward Difference. Symmetry (Basel) 2021. [DOI: 10.3390/sym13061096] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/16/2022] Open
Abstract
This paper develops a novel soft fault diagnosis approach for analog circuits. The proposed method employs the backward difference strategy to process the data, and a novel variant of convolutional neural network, i.e., convolutional neural network with global average pooling (CNN-GAP) is taken for feature extraction and fault classification. Specifically, the measured raw domain response signals are firstly processed by the backward difference strategy and the first-order and the second-order backward difference sequences are generated, which contain the signal variation and the rate of variation characteristics. Then, based on the one-dimensional convolutional neural network, the CNN-GAP is developed by introducing the global average pooling technical. Since global average pooling calculates each input vector’s mean value, the designed CNN-GAP could deal with different lengths of input signals and be applied to diagnose different circuits. Additionally, the first-order and the second-order backward difference sequences along with the raw domain response signals are directly fed into the CNN-GAP, in which the convolutional layers automatically extract and fuse multi-scale features. Finally, fault classification is performed by the fully connected layer of the CNN-GAP. The effectiveness of our proposal is verified by two benchmark circuits under symmetric and asymmetric fault conditions. Experimental results prove that the proposed method outperforms the existing methods in terms of diagnosis accuracy and reliability.
Collapse
|
26
|
A Virtual Instrument for Measuring the Piezoelectric Coefficients of a Thin Disc in Radial Resonant Mode. SENSORS 2021; 21:s21124107. [PMID: 34203765 PMCID: PMC8232585 DOI: 10.3390/s21124107] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 05/17/2021] [Revised: 05/31/2021] [Accepted: 06/08/2021] [Indexed: 11/17/2022]
Abstract
In this paper, we describe and present a Virtual Instrument, a tool that allows the determination of the electromechanical, dielectric, and elastic coefficients in polarised ferroelectric ceramic discs (piezoceramics) in the linear range, including all of the losses when the piezoceramics are vibrating in radial mode. There is no evidence in the recent scientific literature of any automatic system conceived and implemented as a Virtual Instrument based on an iterative algorithm issued as an alternative to solve the limitations of the ANSI IEEE 176 standard for the characterisation of piezoelectric coefficients of thin discs in resonant mode. The characterisation of these coefficients is needed for the design of ultrasonic sensors and generators. In 1995, two of the authors of this work, together with other authors, published an iterative procedure that allowed for the automatic determination of the complex constants for lossy piezoelectric materials in radial mode. As described in this work, the procedures involved in using a Virtual Instrument have been improved: the response time for the characterisation of a piezoelectric sample is shorter (approximately 5 s); the accuracy in measurement and, therefore, in the estimates of the coefficients has been increased; the calculation speed has been increased; an intuitive, simple, and friendly user interface has been designed, and tools have been provided for exporting and inspecting the measured and processed data. No Virtual Instrument has been found in the recent scientific literature that has improved on the iterative procedure designed in 1995. This Virtual Instrument is based on the measurement of a unique magnitude, the electrical admittance (Y = G + iB) in the frequency range of interest. After measuring the electrical admittance, estimates of the set of piezoelectric coefficients of the device are obtained. The programming language used in the construction of the Virtual Instrument is LabVIEW 2019®.
Collapse
|
27
|
Zhang T, Zhang W, Shao X, Yang Y, Wang Z, Wu Y, Pei Y. A Study on Capacitive Micromachined Ultrasonic Transducer Periodic Sparse Array. MICROMACHINES 2021; 12:mi12060684. [PMID: 34208152 PMCID: PMC8230818 DOI: 10.3390/mi12060684] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 04/29/2021] [Revised: 06/07/2021] [Accepted: 06/09/2021] [Indexed: 11/18/2022]
Abstract
Capacitive micromachined ultrasonic transducer (CMUT) is an ultrasonic transducer based on the microelectromechanical system (MEMS). CMUT elements are easily made into a high-density array, which will increase the hardware complexity. In order to reduce the number of active channels, this paper studies the grating lobes generated by CMUT periodic sparse array (PSA) pairs. Through the design of active element positions in the transmitting and receiving processes, the simulation results of effective aperture and beam patterns show that the common grating lobes (CGLs) generated by the transmit and receive array are eliminated. On the basis of point targets imaging, a CMUT linear array with 256 elements is used to carry out the PSA pairs experiment. Under the same sparse factor (SF), the optimal sparse array configuration can be selected to reduce the imaging artifacts. This conclusion is of great significance for the application of CMUT in three-dimensional ultrasound imaging.
Collapse
Affiliation(s)
- Tian Zhang
- State Key Laboratory of Dynamic Testing Technology, North University of China, Taiyuan 030051, China; (T.Z.); (Y.Y.); (Z.W.); (Y.W.); (Y.P.)
- National Key Laboratory for Electronic Measurement Technology, School of Instrument and Electronics, North University of China, Taiyuan 030051, China
| | - Wendong Zhang
- State Key Laboratory of Dynamic Testing Technology, North University of China, Taiyuan 030051, China; (T.Z.); (Y.Y.); (Z.W.); (Y.W.); (Y.P.)
- National Key Laboratory for Electronic Measurement Technology, School of Instrument and Electronics, North University of China, Taiyuan 030051, China
- Correspondence: (W.Z.); (X.S.)
| | - Xingling Shao
- State Key Laboratory of Dynamic Testing Technology, North University of China, Taiyuan 030051, China; (T.Z.); (Y.Y.); (Z.W.); (Y.W.); (Y.P.)
- National Key Laboratory for Electronic Measurement Technology, School of Instrument and Electronics, North University of China, Taiyuan 030051, China
- Correspondence: (W.Z.); (X.S.)
| | - Yuhua Yang
- State Key Laboratory of Dynamic Testing Technology, North University of China, Taiyuan 030051, China; (T.Z.); (Y.Y.); (Z.W.); (Y.W.); (Y.P.)
- National Key Laboratory for Electronic Measurement Technology, School of Instrument and Electronics, North University of China, Taiyuan 030051, China
| | - Zhihao Wang
- State Key Laboratory of Dynamic Testing Technology, North University of China, Taiyuan 030051, China; (T.Z.); (Y.Y.); (Z.W.); (Y.W.); (Y.P.)
- National Key Laboratory for Electronic Measurement Technology, School of Instrument and Electronics, North University of China, Taiyuan 030051, China
| | - Yang Wu
- State Key Laboratory of Dynamic Testing Technology, North University of China, Taiyuan 030051, China; (T.Z.); (Y.Y.); (Z.W.); (Y.W.); (Y.P.)
- National Key Laboratory for Electronic Measurement Technology, School of Instrument and Electronics, North University of China, Taiyuan 030051, China
| | - Yu Pei
- State Key Laboratory of Dynamic Testing Technology, North University of China, Taiyuan 030051, China; (T.Z.); (Y.Y.); (Z.W.); (Y.W.); (Y.P.)
- National Key Laboratory for Electronic Measurement Technology, School of Instrument and Electronics, North University of China, Taiyuan 030051, China
| |
Collapse
|
28
|
Rotational Piezoelectric Energy Harvesting: A Comprehensive Review on Excitation Elements, Designs, and Performances. ENERGIES 2021. [DOI: 10.3390/en14113098] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 02/01/2023]
Abstract
Rotational Piezoelectric Energy Harvesting (RPZTEH) is widely used due to mechanical rotational input power availability in industrial and natural environments. This paper reviews the recent studies and research in RPZTEH based on its excitation elements and design and their influence on performance. It presents different groups for comparison according to their mechanical inputs and applications, such as fluid (air or water) movement, human motion, rotational vehicle tires, and other rotational operational principal including gears. The work emphasises the discussion of different types of excitations elements, such as mass weight, magnetic force, gravity force, centrifugal force, gears teeth, and impact force, to show their effect on enhancing output power. It revealed that a small compact design with the use of magnetic, gravity, and centrifugal forces as excitation elements and a fixed piezoelectric to avoid a slip ring had a good influence on output power optimisation. One of the interesting designs that future works should focus on is using gear for frequency up-conversion to enhance output power density and keep the design simple and compact.
Collapse
|
29
|
Makowski M, Knap L. Study of a Controlled Piezoelectric Damper. SENSORS 2021; 21:s21103509. [PMID: 34069988 PMCID: PMC8157864 DOI: 10.3390/s21103509] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 04/23/2021] [Revised: 05/10/2021] [Accepted: 05/13/2021] [Indexed: 11/16/2022]
Abstract
In this work an original construction of a vibration damper controlled by means of a valve with a short time of operation lag is presented. The valve-controlling properties of the damper regulates the flow of fluid between the chambers of the damper and was constructed using piezoelectric actuators, whose characteristic feature is the possibility to change dimensions, e.g., length, under the influence of voltage. As a result, by changing voltage it is possible to control the throttle of the flow by changing the width of a gap, which influences a change of damping forces. Such a solution enables a quicker change of damping forces than in other kinds of controlled damper. Due to the obtained properties, the damper may be applied to reduce the vibrations of vehicles and machines that undergo quick-change loads. In the article, the results of experimental studies of the aforementioned damper are presented. Based on the results, dissipative characteristics were determined. Also, results of numerical studies comprising the development of a numerical model of a controlled piezoelectric damper are shown. Results of numerical studies, as well as experimental studies, are presented in the form of dissipative characteristics. Comparison of results of numerical and experimental studies confirms the possibility to apply this kind of construction in semi-active systems of vibration reduction of vehicles and machines.
Collapse
|
30
|
Kazys R, Vaskeliene V. High Temperature Ultrasonic Transducers: A Review. SENSORS 2021; 21:s21093200. [PMID: 34062979 PMCID: PMC8125082 DOI: 10.3390/s21093200] [Citation(s) in RCA: 20] [Impact Index Per Article: 6.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 04/08/2021] [Revised: 04/20/2021] [Accepted: 04/29/2021] [Indexed: 11/16/2022]
Abstract
There are many fields such as online monitoring of manufacturing processes, non-destructive testing in nuclear plants, or corrosion rate monitoring techniques of steel pipes in which measurements must be performed at elevated temperatures. For that high temperature ultrasonic transducers are necessary. In the presented paper, a literature review on the main types of such transducers, piezoelectric materials, backings, and the bonding techniques of transducers elements suitable for high temperatures, is presented. In this review, the main focus is on ultrasonic transducers with piezoelectric elements suitable for operation at temperatures higher than of the most commercially available transducers, i.e., 150 °C. The main types of the ultrasonic transducers that are discussed are the transducers with thin protectors, which may serve as matching layers, transducers with high temperature delay lines, wedges, and waveguide type transducers. The piezoelectric materials suitable for high temperature applications such as aluminum nitride, lithium niobate, gallium orthophosphate, bismuth titanate, oxyborate crystals, lead metaniobate, and other piezoceramics are analyzed. Bonding techniques used for joining of the transducer elements such as joining with glue, soldering, brazing, dry contact, and diffusion bonding are discussed. Special attention is paid to efficient diffusion and thermo-sonic diffusion bonding techniques. Various types of backings necessary for improving a bandwidth and to obtain a short pulse response are described.
Collapse
|
31
|
A New Approach to Power Efficiency Improvement of Ultrasonic Transmitters via a Dynamic Bias Technique. SENSORS 2021; 21:s21082795. [PMID: 33921082 PMCID: PMC8071451 DOI: 10.3390/s21082795] [Citation(s) in RCA: 9] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 03/12/2021] [Revised: 04/07/2021] [Accepted: 04/12/2021] [Indexed: 12/17/2022]
Abstract
To obtain a high-quality signal from an ultrasound system through the transmitter, it is necessary to achieve an appropriate operating point of the power amplifier in the ultrasonic transmitter by applying high static bias voltage. However, the power amplifier needs to be operated at low bias voltage, because a power amplifier operating at high bias voltage may consume a large amount of power and increase the temperature of the active devices, worsening the signal characteristics of the ultrasound systems. Therefore, we propose a new method of increasing the bias voltage for a specific period to solve this problem by reducing the output signal distortion of the power amplifier and decreasing the load on the active device. To compare the performance of the proposed method, we measured and compared the signals of the amplifier with the proposed technique and the amplifier only. Notably, improvement was achieved with 11.1% of the power added efficiency and 3.23% of the total harmonic distortion (THD). Additionally, the echo signal generated by the ultrasonic transducer was improved by 2.73 dB of amplitude and 0.028% of THD under the conditions of an input signal of 10 mW. Therefore, the proposed method could be useful for improving ultrasonic transmitter performance using the developed technique.
Collapse
|