1
|
Khaledyan D, Marini TJ, O’Connell A, Meng S, Kan J, Brennan G, Zhao Y, Baran TM, Parker KJ. WATUNet: a deep neural network for segmentation of volumetric sweep imaging ultrasound. MACHINE LEARNING: SCIENCE AND TECHNOLOGY 2024; 5:015042. [PMID: 38464559 PMCID: PMC10921088 DOI: 10.1088/2632-2153/ad2e15] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/03/2023] [Revised: 01/31/2024] [Accepted: 02/28/2024] [Indexed: 03/12/2024] Open
Abstract
Limited access to breast cancer diagnosis globally leads to delayed treatment. Ultrasound, an effective yet underutilized method, requires specialized training for sonographers, which hinders its widespread use. Volume sweep imaging (VSI) is an innovative approach that enables untrained operators to capture high-quality ultrasound images. Combined with deep learning, like convolutional neural networks, it can potentially transform breast cancer diagnosis, enhancing accuracy, saving time and costs, and improving patient outcomes. The widely used UNet architecture, known for medical image segmentation, has limitations, such as vanishing gradients and a lack of multi-scale feature extraction and selective region attention. In this study, we present a novel segmentation model known as Wavelet_Attention_UNet (WATUNet). In this model, we incorporate wavelet gates and attention gates between the encoder and decoder instead of a simple connection to overcome the limitations mentioned, thereby improving model performance. Two datasets are utilized for the analysis: the public 'Breast Ultrasound Images' dataset of 780 images and a private VSI dataset of 3818 images, captured at the University of Rochester by the authors. Both datasets contained segmented lesions categorized into three types: no mass, benign mass, and malignant mass. Our segmentation results show superior performance compared to other deep networks. The proposed algorithm attained a Dice coefficient of 0.94 and an F1 score of 0.94 on the VSI dataset and scored 0.93 and 0.94 on the public dataset, respectively. Moreover, our model significantly outperformed other models in McNemar's test with false discovery rate correction on a 381-image VSI set. The experimental findings demonstrate that the proposed WATUNet model achieves precise segmentation of breast lesions in both standard-of-care and VSI images, surpassing state-of-the-art models. Hence, the model holds considerable promise for assisting in lesion identification, an essential step in the clinical diagnosis of breast lesions.
Collapse
Affiliation(s)
- Donya Khaledyan
- Department of Electrical and Computer Engineering, University of Rochester, Rochester, NY, United States of America
| | - Thomas J Marini
- Department of Imaging Sciences, University of Rochester Medical Center, Rochester, NY, United States of America
| | - Avice O’Connell
- Department of Imaging Sciences, University of Rochester Medical Center, Rochester, NY, United States of America
| | - Steven Meng
- Department of Imaging Sciences, University of Rochester Medical Center, Rochester, NY, United States of America
| | - Jonah Kan
- Department of Imaging Sciences, University of Rochester Medical Center, Rochester, NY, United States of America
| | - Galen Brennan
- Department of Imaging Sciences, University of Rochester Medical Center, Rochester, NY, United States of America
| | - Yu Zhao
- Department of Imaging Sciences, University of Rochester Medical Center, Rochester, NY, United States of America
| | - Timothy M Baran
- Department of Imaging Sciences, University of Rochester Medical Center, Rochester, NY, United States of America
| | - Kevin J Parker
- Department of Electrical and Computer Engineering, University of Rochester, Rochester, NY, United States of America
- Department of Imaging Sciences, University of Rochester Medical Center, Rochester, NY, United States of America
| |
Collapse
|
2
|
Liang WH, Chan SC, Lee HH, Hung SC, Lin CC, Chen CJ, Chen MJ, Lai JH. Feasibility and Safety of 5G-Based Telerobotic Abdominal Ultrasonography. JOURNAL OF ULTRASOUND IN MEDICINE : OFFICIAL JOURNAL OF THE AMERICAN INSTITUTE OF ULTRASOUND IN MEDICINE 2024; 43:355-360. [PMID: 37916293 DOI: 10.1002/jum.16368] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 10/15/2023] [Accepted: 10/18/2023] [Indexed: 11/03/2023]
Abstract
OBJECTIVE Telemedicine can offer services to remote patients regardless of the distance. Fifth-generation (5G) mobile networks may make telemedicine practical because of their low latency. This study aimed to evaluate the feasibility and safety of a novel 5G robot-assisted remote abdominal ultrasound (AUS) telemedicine technology in clinical applications in distant locations. METHODS We performed 5G-based telerobotic AUS in patients who were located more than 100 km away from the physicians. RESULTS The telerobotic AUS had a longer examination time than the conditional bedside AUS; however, the complete examination rate was not inferior. None of the volunteers experienced discomfort during the examination and the examination time was acceptable for all. CONCLUSION Our findings confirm the feasibility and safety of 5G-based telerobotic AUS in clinical practice.
Collapse
Affiliation(s)
- Wei-Hsin Liang
- Division of Gastroenterology, Department of Internal Medicine, Mackay Memorial Hospital, Taipei, Taiwan
| | - Sean-Chen Chan
- Division of Gastroenterology, Department of Internal Medicine, Mackay Memorial Hospital, Taipei, Taiwan
| | - Ho-Hsin Lee
- Service Systems Technology Center, Industrial Technology Research Institute, Hsinchu City, Taiwan
| | - Shang-Chih Hung
- Service Systems Technology Center, Industrial Technology Research Institute, Hsinchu City, Taiwan
| | - Ching-Chung Lin
- Division of Gastroenterology, Department of Internal Medicine, Mackay Memorial Hospital, Taipei, Taiwan
- Mackay Medical College, New Taipei, Taiwan
| | - Chih-Jen Chen
- Division of Gastroenterology, Department of Internal Medicine, Mackay Memorial Hospital, Taipei, Taiwan
| | - Ming-Jen Chen
- Division of Gastroenterology, Department of Internal Medicine, Mackay Memorial Hospital, Taipei, Taiwan
- Mackay Medical College, New Taipei, Taiwan
| | - Jian-Han Lai
- Division of Gastroenterology, Department of Internal Medicine, Mackay Memorial Hospital, Taipei, Taiwan
- Mackay Medical College, New Taipei, Taiwan
| |
Collapse
|
3
|
Khaledyan D, Marini TJ, M. Baran T, O’Connell A, Parker K. Enhancing breast ultrasound segmentation through fine-tuning and optimization techniques: Sharp attention UNet. PLoS One 2023; 18:e0289195. [PMID: 38091358 PMCID: PMC10718429 DOI: 10.1371/journal.pone.0289195] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/12/2023] [Accepted: 09/03/2023] [Indexed: 12/18/2023] Open
Abstract
Segmentation of breast ultrasound images is a crucial and challenging task in computer-aided diagnosis systems. Accurately segmenting masses in benign and malignant cases and identifying regions with no mass is a primary objective in breast ultrasound image segmentation. Deep learning (DL) has emerged as a powerful tool in medical image segmentation, revolutionizing how medical professionals analyze and interpret complex imaging data. The UNet architecture is a highly regarded and widely used DL model in medical image segmentation. Its distinctive architectural design and exceptional performance have made it popular among researchers. With the increase in data and model complexity, optimization and fine-tuning models play a vital and more challenging role than before. This paper presents a comparative study evaluating the effect of image preprocessing and different optimization techniques and the importance of fine-tuning different UNet segmentation models for breast ultrasound images. Optimization and fine-tuning techniques have been applied to enhance the performance of UNet, Sharp UNet, and Attention UNet. Building upon this progress, we designed a novel approach by combining Sharp UNet and Attention UNet, known as Sharp Attention UNet. Our analysis yielded the following quantitative evaluation metrics for the Sharp Attention UNet: the Dice coefficient, specificity, sensitivity, and F1 score values obtained were 0.93, 0.99, 0.94, and 0.94, respectively. In addition, McNemar's statistical test was applied to assess significant differences between the approaches. Across a number of measures, our proposed model outperformed all other models, resulting in improved breast lesion segmentation.
Collapse
Affiliation(s)
- Donya Khaledyan
- Department of Electrical and Electronics Engineering, University of Rochester, Rochester, NY, United States of America
| | - Thomas J. Marini
- Department of Imaging Sciences, University of Rochester Medical Center, Rochester, NY, United States of America
| | - Timothy M. Baran
- Department of Imaging Sciences, University of Rochester Medical Center, Rochester, NY, United States of America
| | - Avice O’Connell
- Department of Imaging Sciences, University of Rochester Medical Center, Rochester, NY, United States of America
| | - Kevin Parker
- Department of Electrical and Electronics Engineering, University of Rochester, Rochester, NY, United States of America
- Department of Imaging Sciences, University of Rochester Medical Center, Rochester, NY, United States of America
| |
Collapse
|
4
|
Shi R, Rosario J. Paramedic-Performed Prehospital Tele-Ultrasound: A Powerful Technology or an Impractical Endeavor? A Scoping Review. Prehosp Disaster Med 2023; 38:645-653. [PMID: 37622570 PMCID: PMC10548023 DOI: 10.1017/s1049023x23006234] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/24/2023] [Revised: 06/26/2023] [Accepted: 07/06/2023] [Indexed: 08/26/2023]
Abstract
Ultrasound with remote assistance (tele-ultrasound) may have potential to improve accessibility of ultrasound for prehospital patients. A review of recent literature on this topic has not been done before, and the feasibility of prehospital tele-ultrasound performed by non-physician personnel is unclear. In an effort to address this, the literature was qualitatively analyzed from January 1, 2010 - December 31, 2021 in the MEDLINE, EMBASE, and Cochrane online databases on prehospital, paramedic-acquired tele-ultrasound, and ten articles were found. There was considerable heterogeneity in the study design, technologies used, and the amount of ultrasound training for the paramedics, preventing cross-comparisons of different studies. Tele-ultrasound has potential to improve ultrasound accessibility by leveraging skills of a remote ultrasound expert, but there are still technological barriers to overcome before determinations on feasibility can be made.
Collapse
Affiliation(s)
- Rachel Shi
- University of Central Florida College of Medicine, Orlando, Florida, USA
| | - Javier Rosario
- University of Central Florida College of Medicine, Orlando, Florida, USA
| |
Collapse
|
5
|
Erlick M, Marini T, Drennan K, Dozier A, Castaneda B, Baran T, Toscano M. Assessment of a Brief Standardized Obstetric Ultrasound Training Program for Individuals Without Prior Ultrasound Experience. Ultrasound Q 2023; 39:124-128. [PMID: 36223486 DOI: 10.1097/ruq.0000000000000626] [Citation(s) in RCA: 6] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 04/05/2023]
Abstract
ABSTRACT Obstetric volume sweep imaging (OB VSI) is a simple set of transducer movements guided by external body landmarks that can be taught to ultrasound-naive non-experts. This approach can increase access to ultrasound in rural/low-resources settings lacking trained sonographers. This study presents and evaluates a training program for OB VSI. Six trainees without previous formal ultrasound experience received a training program on the OB VSI protocol containing focused didactics and supervised live hands-on ultrasound scanning practice. Trainees then independently performed 194 OB VSI examinations on pregnancies >14 weeks with known prenatal ultrasound abnormalities. Images were reviewed by maternal-fetal medicine specialists for the primary outcome (protocol deviation rates) and secondary outcomes (examination quality and image quality). Protocol deviation was present in 25.8% of cases, but only 7.7% of these errors affected the diagnostic potential of the ultrasound. Error rate differences between trainees ranged from 8.6% to 53.8% ( P < 0.0001). Image quality was excellent or acceptable in 88.2%, and 96.4% had image quality capable of yielding a diagnostic interpretation. The frequency of protocol deviations decreased over time in the majority of trainees, demonstrating retention of training program over time. This brief OB VSI training program for ultrasound-naive non-experts yielded operators capable of producing high-quality images capable of diagnostic interpretation after 3 hours of training. This training program could be adapted for use by local community members in low-resource/rural settings to increase access to obstetric ultrasound.
Collapse
Affiliation(s)
- Mariah Erlick
- University of Rochester School of Medicine and Dentistry
| | - Thomas Marini
- Department of Imaging Sciences, University of Rochester Medical Center
| | - Kathryn Drennan
- Department of Obstetrics and Gynecology, University of Rochester Medical Center
| | - Ann Dozier
- Department of Public Health Sciences, University of Rochester Medical Center
| | - Benjamin Castaneda
- Laboratorio de Imágenes Médicas, Departamento de Ingeniería, Pontificia Universidad Católica del Perú
| | - Timothy Baran
- Department of Imaging Sciences, The Institute for Optics, Department of Biomedical Engineering, University of Rochester Medical Center
| | - Marika Toscano
- Department of Obstetrics and Gynecology, University of Rochester Medical Center
| |
Collapse
|
6
|
Khaledyan D, Marini TJ, O’Connell A, Parker K. Enhancing Breast Ultrasound Segmentation through Fine-tuning and Optimization Techniques: Sharp Attention UNet. BIORXIV : THE PREPRINT SERVER FOR BIOLOGY 2023:2023.07.14.549040. [PMID: 37503223 PMCID: PMC10370074 DOI: 10.1101/2023.07.14.549040] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 07/29/2023]
Abstract
Segmentation of breast ultrasound images is a crucial and challenging task in computer-aided diagnosis systems. Accurately segmenting masses in benign and malignant cases and identifying regions with no mass is a primary objective in breast ultrasound image segmentation. Deep learning (DL) has emerged as a powerful tool in medical image segmentation, revolutionizing how medical professionals analyze and interpret complex imaging data. The UNet architecture is a highly regarded and widely used DL model in medical image segmentation. Its distinctive architectural design and exceptional performance have made it a popular choice among researchers in the medical image segmentation field. With the increase in data and model complexity, optimization and fine-tuning models play a vital and more challenging role than before. This paper presents a comparative study evaluating the effect of image preprocessing and different optimization techniques and the importance of fine-tuning different UNet segmentation models for breast ultrasound images. Optimization and fine-tuning techniques have been applied to enhance the performance of UNet, Sharp UNet, and Attention UNet. Building upon this progress, we designed a novel approach by combining Sharp UNet and Attention UNet, known as Sharp Attention UNet. Our analysis yielded the following quantitative evaluation metrics for the Sharp Attention UNet: the dice coefficient, specificity, sensitivity, and F1 score obtained values of 0.9283, 0.9936, 0.9426, and 0.9412, respectively. In addition, McNemar's statistical test was applied to assess significant differences between the approaches. Across a number of measures, our proposed model outperforms the earlier designed models and points towards improved breast lesion segmentation algorithms.
Collapse
Affiliation(s)
- Donya Khaledyan
- Department of Electrical and Electronics Engineering, University of Rochester, Rochester, NY, USA
| | - Thomas J. Marini
- Department of Imaging Sciences, University of Rochester Medical Center, Rochester, NY, USA
| | - Avice O’Connell
- Department of Imaging Sciences, University of Rochester Medical Center, Rochester, NY, USA
| | - Kevin Parker
- Department of Electrical and Electronics Engineering, University of Rochester, Rochester, NY, USA
- Department of Imaging Sciences, University of Rochester Medical Center, Rochester, NY, USA
| |
Collapse
|
7
|
Curioso WH, Coronel-Chucos LG, Henríquez-Suarez M. Integrating Telehealth for Strengthening Health Systems in the Context of the COVID-19 Pandemic: A Perspective from Peru. INTERNATIONAL JOURNAL OF ENVIRONMENTAL RESEARCH AND PUBLIC HEALTH 2023; 20:5980. [PMID: 37297584 PMCID: PMC10252887 DOI: 10.3390/ijerph20115980] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 03/01/2023] [Revised: 05/02/2023] [Accepted: 05/25/2023] [Indexed: 06/12/2023]
Abstract
The COVID-19 pandemic forced the government to rapidly modify its legal framework to adopt telemedicine and promote the implementation of telehealth services to meet the healthcare needs of patients in Peru. In this paper, we aim to review the main changes to the regulatory framework and describe selected initiatives to promote the telehealth framework that emerged in Peru during the COVID-19 pandemic. In addition, we discuss the challenges to integrate telehealth services for strengthening health systems in Peru. The Peruvian telehealth regulatory framework began in 2005, and in subsequent years, laws and regulations were established that sought to progressively implement a national telehealth network. However, mainly local initiatives were deployed. In this sense, significant challenges remain to be addressed, such as infrastructure in healthcare centers, including high-speed Internet connectivity; infostructure of health-information systems, including interoperability with electronic medical records; monitoring and evaluation of the national agenda for the health sector in 2020-2025; expanding the healthcare workforce in terms of digital health; and developing the capacities of healthcare users on health literacy, including digital aspects. In addition, there is enormous potential for telemedicine as a key strategy to deal with the COVID-19 pandemic and to improve access to rural and hard-to-reach areas and populations. There is thus an urgent need to effectively implement an integrated national telehealth system to address sociocultural issues and strengthen the competencies of human resources in telehealth and digital health in Peru.
Collapse
Affiliation(s)
- Walter H. Curioso
- Vicerrectorado de Investigación, Universidad Continental, Lima 15046, Peru
- Health Services Administration, Continental University of Florida, Margate, FL 33063, USA
| | | | | |
Collapse
|
8
|
Toscano M, Marini T, Lennon C, Erlick M, Silva H, Crofton K, Serratelli W, Rana N, Dozier AM, Castaneda B, Baran TM, Drennan K. Diagnosis of Pregnancy Complications Using Blind Ultrasound Sweeps Performed by Individuals Without Prior Formal Ultrasound Training. Obstet Gynecol 2023; 141:937-948. [PMID: 37103534 DOI: 10.1097/aog.0000000000005139] [Citation(s) in RCA: 2] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/21/2022] [Accepted: 01/22/2023] [Indexed: 04/28/2023]
Abstract
OBJECTIVE To estimate the diagnostic accuracy of blind ultrasound sweeps performed with a low-cost, portable ultrasound system by individuals with no prior formal ultrasound training to diagnose common pregnancy complications. METHODS This is a single-center, prospective cohort study conducted from October 2020 to January 2022 among people with second- and third-trimester pregnancies. Nonspecialists with no prior formal ultrasound training underwent a brief training on a simple eight-step approach to performing a limited obstetric ultrasound examination that uses blind sweeps of a portable ultrasound probe based on external body landmarks. The sweeps were interpreted by five blinded maternal-fetal medicine subspecialists. Sensitivity, specificity, and positive and negative predictive values for blinded ultrasound sweep identification of pregnancy complications (fetal malpresentation, multiple gestations, placenta previa, and abnormal amniotic fluid volume) were compared with a reference standard ultrasonogram as the primary analysis. Kappa for agreement was also assessed. RESULTS Trainees performed 194 blinded ultrasound examinations on 168 unique pregnant people (248 fetuses) at a mean of 28±5.85 weeks of gestation for a total of 1,552 blinded sweep cine clips. There were 49 ultrasonograms with normal results (control group) and 145 ultrasonograms with abnormal results with known pregnancy complications. In this cohort, the sensitivity for detecting a prespecified pregnancy complication was 91.7% (95% CI 87.2-96.2%) overall, with the highest detection rate for multiple gestations (100%, 95% CI 100-100%) and noncephalic presentation (91.8%, 95% CI 86.4-97.3%). There was high negative predictive value for placenta previa (96.1%, 95% CI 93.5-98.8%) and abnormal amniotic fluid volume (89.5%, 95% CI 85.3-93.6%). There was also substantial to perfect mean agreement for these same outcomes (range 87-99.6% agreement, Cohen κ range 0.59-0.91, P<.001 for all). CONCLUSION Blind ultrasound sweeps of the gravid abdomen guided by an eight-step protocol using only external anatomic landmarks and performed by previously untrained operators with a low-cost, portable, battery-powered device had excellent sensitivity and specificity for high-risk pregnancy complications such as malpresentation, placenta previa, multiple gestations, and abnormal amniotic fluid volume, similar to results of a diagnostic ultrasound examination using a trained ultrasonographer and standard-of-care ultrasound machine. This approach has the potential to improve access to obstetric ultrasonography globally.
Collapse
Affiliation(s)
- Marika Toscano
- Division of Maternal-Fetal Medicine, Department of Gynecology & Obstetrics, Johns Hopkins University School of Medicine, Baltimore, Maryland; the Department of Imaging Sciences, the Department of Public Health Sciences, and the Department of Obstetrics & Gynecology, University of Rochester Medical Center, and the University of Rochester School of Medicine and Dentistry, Rochester, New York; and the Division of Electric Engineering, Department of Academic Engineering, Pontificia Universidad Catolica del Peru, Lima, Peru
| | | | | | | | | | | | | | | | | | | | | | | |
Collapse
|
9
|
Marini TJ, Castaneda B, Satheesh M, Zhao YT, Reátegui-Rivera CM, Sifuentes W, Baran TM, Kaproth-Joslin KA, Ambrosini R, Rios-Mayhua G, Dozier AM. Sustainable volume sweep imaging lung teleultrasound in Peru: Public health perspectives from a new frontier in expanding access to imaging. FRONTIERS IN HEALTH SERVICES 2023; 3:1002208. [PMID: 37077694 PMCID: PMC10106710 DOI: 10.3389/frhs.2023.1002208] [Citation(s) in RCA: 2] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Received: 07/24/2022] [Accepted: 02/27/2023] [Indexed: 04/05/2023]
Abstract
BackgroundPulmonary disease is a common cause of morbidity and mortality, but the majority of the people in the world lack access to diagnostic imaging for its assessment. We conducted an implementation assessment of a potentially sustainable and cost-effective model for delivery of volume sweep imaging (VSI) lung teleultrasound in Peru. This model allows image acquisition by individuals without prior ultrasound experience after only a few hours of training.MethodsLung teleultrasound was implemented at 5 sites in rural Peru after a few hours of installation and staff training. Patients were offered free lung VSI teleultrasound examination for concerns of respiratory illness or research purposes. After ultrasound examination, patients were surveyed regarding their experience. Health staff and members of the implementation team also participated in separate interviews detailing their views of the teleultrasound system which were systematically analyzed for key themes.ResultsPatients and staff rated their experience with lung teleultrasound as overwhelmingly positive. The lung teleultrasound system was viewed as a potential way to improve access to imaging and the health of rural communities. Detailed interviews with the implementation team revealed obstacles to implementation important for consideration such as gaps in lung ultrasound understanding.ConclusionsLung VSI teleultrasound was successfully deployed to 5 health centers in rural Peru. Implementation assessment revealed enthusiasm for the system among members of the community along with important areas of consideration for future teleultrasound deployment. This system offers a potential means to increase access to imaging for pulmonary illness and improve the health of the global community.
Collapse
Affiliation(s)
- Thomas J. Marini
- Department of Imaging Sciences, University of Rochester Medical Center, Rochester, NY, United States
- Correspondence: Thomas J. Marini
| | - Benjamin Castaneda
- Departamento de Ingeniería, Laboratorio de Imágenes Médicas, Pontificia Universidad Católica del Perú, Lima, Peru
| | - Malavika Satheesh
- Department of Imaging Sciences, University of Rochester Medical Center, Rochester, NY, United States
| | - Yu T. Zhao
- Department of Imaging Sciences, University of Rochester Medical Center, Rochester, NY, United States
| | | | | | - Timothy M. Baran
- Department of Imaging Sciences, University of Rochester Medical Center, Rochester, NY, United States
| | | | - Robert Ambrosini
- Department of Imaging Sciences, University of Rochester Medical Center, Rochester, NY, United States
| | | | - Ann M. Dozier
- Department of Public Health, University of Rochester Medical Center, Rochester, NY, United States
| |
Collapse
|
10
|
Marini TJ, Castaneda B, Iyer R, Baran TM, Nemer O, Dozier AM, Parker KJ, Zhao Y, Serratelli W, Matos G, Ali S, Ghobryal B, Visca A, O'Connell A. Breast Ultrasound Volume Sweep Imaging: A New Horizon in Expanding Imaging Access for Breast Cancer Detection. JOURNAL OF ULTRASOUND IN MEDICINE : OFFICIAL JOURNAL OF THE AMERICAN INSTITUTE OF ULTRASOUND IN MEDICINE 2023; 42:817-832. [PMID: 35802491 DOI: 10.1002/jum.16047] [Citation(s) in RCA: 8] [Impact Index Per Article: 4.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 05/02/2022] [Revised: 06/11/2022] [Accepted: 06/13/2022] [Indexed: 05/26/2023]
Abstract
OBJECTIVE The majority of people in the world lack basic access to breast diagnostic imaging resulting in delay to diagnosis of breast cancer. In this study, we tested a volume sweep imaging (VSI) ultrasound protocol for evaluation of palpable breast lumps that can be performed by operators after minimal training without prior ultrasound experience as a means to increase accessibility to breast ultrasound. METHODS Medical students without prior ultrasound experience were trained for less than 2 hours on the VSI breast ultrasound protocol. Patients presenting with palpable breast lumps for standard of care ultrasound examination were scanned by a trained medical student with the VSI protocol using a Butterfly iQ handheld ultrasound probe. Video clips of the VSI scan imaging were later interpreted by an attending breast imager. Results of VSI scan interpretation were compared to the same-day standard of care ultrasound examination. RESULTS Medical students scanned 170 palpable lumps with the VSI protocol. There was 97% sensitivity and 100% specificity for a breast mass on VSI corresponding to 97.6% agreement with standard of care (Cohen's κ = 0.95, P < .0001). There was a detection rate of 100% for all cancer presenting as a sonographic mass. High agreement for mass characteristics between VSI and standard of care was observed, including 87% agreement on Breast Imaging-Reporting and Data System assessments (Cohen's κ = 0.82, P < .0001). CONCLUSIONS Breast ultrasound VSI for palpable lumps offers a promising means to increase access to diagnostic imaging in underserved areas. This approach could decrease delay to diagnosis for breast cancer, potentially improving morbidity and mortality.
Collapse
Affiliation(s)
| | | | - Radha Iyer
- University of Rochester Medical Center, Rochester, NY, USA
| | | | - Omar Nemer
- University of Rochester Medical Center, Rochester, NY, USA
| | - Ann M Dozier
- University of Rochester Medical Center, Rochester, NY, USA
| | - Kevin J Parker
- University of Rochester Medical Center, Rochester, NY, USA
| | - Yu Zhao
- University of Rochester Medical Center, Rochester, NY, USA
| | | | - Gregory Matos
- University of Rochester Medical Center, Rochester, NY, USA
| | - Shania Ali
- University of Rochester Medical Center, Rochester, NY, USA
| | | | - Adam Visca
- University of Rochester Medical Center, Rochester, NY, USA
| | | |
Collapse
|
11
|
Maita KC, Palmieri-Serrano L, Avila FR, Torres-Guzman RA, Garcia JP, S. Eldaly A, Haider CR, Felton CL, Paulson MR, Maniaci MJ, Forte AJ. Imaging evaluated remotely through telemedicine as a reliable alternative for accurate diagnosis: a systematic review. HEALTH AND TECHNOLOGY 2023. [DOI: 10.1007/s12553-023-00745-3] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 03/29/2023]
|
12
|
Marini TJ, Castaneda B, Parker K, Baran TM, Romero S, Iyer R, Zhao YT, Hah Z, Park MH, Brennan G, Kan J, Meng S, Dozier A, O’Connell A. No sonographer, no radiologist: Assessing accuracy of artificial intelligence on breast ultrasound volume sweep imaging scans. PLOS DIGITAL HEALTH 2022; 1:e0000148. [PMID: 36812553 PMCID: PMC9931251 DOI: 10.1371/journal.pdig.0000148] [Citation(s) in RCA: 6] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 02/23/2022] [Accepted: 10/21/2022] [Indexed: 05/12/2023]
Abstract
Breast ultrasound provides a first-line evaluation for breast masses, but the majority of the world lacks access to any form of diagnostic imaging. In this pilot study, we assessed the combination of artificial intelligence (Samsung S-Detect for Breast) with volume sweep imaging (VSI) ultrasound scans to evaluate the possibility of inexpensive, fully automated breast ultrasound acquisition and preliminary interpretation without an experienced sonographer or radiologist. This study was conducted using examinations from a curated data set from a previously published clinical study of breast VSI. Examinations in this data set were obtained by medical students without prior ultrasound experience who performed VSI using a portable Butterfly iQ ultrasound probe. Standard of care ultrasound exams were performed concurrently by an experienced sonographer using a high-end ultrasound machine. Expert-selected VSI images and standard of care images were input into S-Detect which output mass features and classification as "possibly benign" and "possibly malignant." Subsequent comparison of the S-Detect VSI report was made between 1) the standard of care ultrasound report by an expert radiologist, 2) the standard of care ultrasound S-Detect report, 3) the VSI report by an expert radiologist, and 4) the pathological diagnosis. There were 115 masses analyzed by S-Detect from the curated data set. There was substantial agreement of the S-Detect interpretation of VSI among cancers, cysts, fibroadenomas, and lipomas to the expert standard of care ultrasound report (Cohen's κ = 0.73 (0.57-0.9 95% CI), p<0.0001), the standard of care ultrasound S-Detect interpretation (Cohen's κ = 0.79 (0.65-0.94 95% CI), p<0.0001), the expert VSI ultrasound report (Cohen's κ = 0.73 (0.57-0.9 95% CI), p<0.0001), and the pathological diagnosis (Cohen's κ = 0.80 (0.64-0.95 95% CI), p<0.0001). All pathologically proven cancers (n = 20) were designated as "possibly malignant" by S-Detect with a sensitivity of 100% and specificity of 86%. Integration of artificial intelligence and VSI could allow both acquisition and interpretation of ultrasound images without a sonographer and radiologist. This approach holds potential for increasing access to ultrasound imaging and therefore improving outcomes related to breast cancer in low- and middle- income countries.
Collapse
Affiliation(s)
- Thomas J. Marini
- Department of Imaging Sciences, University of Rochester Medical Center, Rochester, New York, United States of America
- * E-mail:
| | - Benjamin Castaneda
- Departamento de Ingeniería, Pontificia Universidad Católica del Perú, Lima, Peru
| | - Kevin Parker
- Department of Imaging Sciences, University of Rochester Medical Center, Rochester, New York, United States of America
| | - Timothy M. Baran
- Department of Imaging Sciences, University of Rochester Medical Center, Rochester, New York, United States of America
| | - Stefano Romero
- Departamento de Ingeniería, Pontificia Universidad Católica del Perú, Lima, Peru
| | - Radha Iyer
- Department of Imaging Sciences, University of Rochester Medical Center, Rochester, New York, United States of America
| | - Yu T. Zhao
- Department of Imaging Sciences, University of Rochester Medical Center, Rochester, New York, United States of America
| | - Zaegyoo Hah
- Samsung Medison Co., Ltd., Seoul, Republic of Korea
| | - Moon Ho Park
- Samsung Electronics Co., Ltd., Seoul, Republic of Korea
| | - Galen Brennan
- Department of Imaging Sciences, University of Rochester Medical Center, Rochester, New York, United States of America
| | - Jonah Kan
- Department of Imaging Sciences, University of Rochester Medical Center, Rochester, New York, United States of America
| | - Steven Meng
- Department of Imaging Sciences, University of Rochester Medical Center, Rochester, New York, United States of America
| | - Ann Dozier
- Department of Public Health, University of Rochester Medical Center, Rochester, New York, United States of America
| | - Avice O’Connell
- Department of Imaging Sciences, University of Rochester Medical Center, Rochester, New York, United States of America
| |
Collapse
|
13
|
Morel B, Hellec C, Fievet A, Taveau CS, Abimelech M, Dujardin PA, Brunereau L, Patat F. Reliability of 3-D Virtual Abdominal Tele-ultrasonography in Pediatric Emergency: Comparison with Standard-of-Care Ultrasound Examination. ULTRASOUND IN MEDICINE & BIOLOGY 2022; 48:2310-2321. [PMID: 36055859 DOI: 10.1016/j.ultrasmedbio.2022.07.004] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 01/10/2022] [Revised: 06/01/2022] [Accepted: 07/09/2022] [Indexed: 06/15/2023]
Abstract
Ultrasound is currently recommended as the first-line examination for abdominal symptoms in children. However, a pediatric radiologist is not always available on site, especially during on-call duty. This study was aimed at evaluating the reliability of an innovative 3-D virtual abdominal tele-ultrasonography in this context. A prospective study was conducted between December 2020 and May 2021 that recruited 103 children undergoing ultrasound for abdominal pain. Trauma cases were excluded. Four tridimensional acquisitions were performed with a Smart Sensor 3D device (Canon Medical Systems, Otawara, Japan). Each tele-ultrasonography was secondarily blindly reviewed by two radiologists (one senior and one resident) with Fusion software (Canon Medical Systems). Acceptance and quality of the acquisitions were evaluated on a Likert scale. Inter-rater reliability was quantified using Cohen's κ coefficient and intraclass correlation coefficient. The ultrasound examination was normal in 66 cases (64%), abnormal in 36 cases (35%) and inconclusive in 1 case (1%). The acquisitions were obtained without objections from the children, their parents or the operators in more than 95% of cases. The quality of the acquisitions was considered good to excellent in 84% and 70% of cases. The sensitivity of the senior radiologist and the resident was 86% and 84%, respectively; specificity was 95% and 92%, positive predictive value 92% and 86% and negative predictive value 92 and 91% when comparing the conclusions of the standard and the tele-ultrasound examinations. Cohen's κ coefficients of the diagnosis obtained with the standard and the tele-ultrasound examinations were 0.82 and 0.71, respectively. The inter-rater Cohen's κ coefficient was 0.84. The intraclass correlation coefficient between the standard abdominal examination and the 3-D tele-ultrasound reformatted images for the following quantitative variables on pathological cases was 0.99 (confidence interval: 0.98-0.99). Virtual abdominal tele-ultrasonography is a promising method in pediatric emergencies.
Collapse
Affiliation(s)
- Baptiste Morel
- UMR 1253, iBrain, Université de Tours, INSERM, Tours, France; Pediatric Radiology Department, Clocheville Hospital, CHRU de Tours, Tours, France.
| | - Corentin Hellec
- Pediatric Radiology Department, Clocheville Hospital, CHRU de Tours, Tours, France
| | - Adèle Fievet
- Pediatric Radiology Department, Clocheville Hospital, CHRU de Tours, Tours, France
| | | | - Martine Abimelech
- Pediatric Radiology Department, Regional Hospital of Orleans, Orleans, France
| | | | | | - Frédéric Patat
- UMR 1253, iBrain, Université de Tours, INSERM, Tours, France; Clinical Investigation Center, INSERM 1415, CHRU Tours, Tours, France
| |
Collapse
|
14
|
Marini TJ, Kaproth-Joslin K, Ambrosini R, Baran TM, Dozier AM, Zhao YT, Satheesh M, Mahony Reátegui-Rivera C, Sifuentes W, Rios-Mayhua G, Castaneda B. Volume sweep imaging lung teleultrasound for detection of COVID-19 in Peru: a multicentre pilot study. BMJ Open 2022; 12:e061332. [PMID: 36192102 PMCID: PMC9534786 DOI: 10.1136/bmjopen-2022-061332] [Citation(s) in RCA: 8] [Impact Index Per Article: 2.7] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 01/26/2022] [Accepted: 08/03/2022] [Indexed: 11/30/2022] Open
Abstract
OBJECTIVES Pulmonary disease is a significant cause of morbidity and mortality in adults and children, but most of the world lacks diagnostic imaging for its assessment. Lung ultrasound is a portable, low-cost, and highly accurate imaging modality for assessment of pulmonary pathology including pneumonia, but its deployment is limited secondary to a lack of trained sonographers. In this study, we piloted a low-cost lung teleultrasound system in rural Peru during the COVID-19 pandemic using lung ultrasound volume sweep imaging (VSI) that can be operated by an individual without prior ultrasound training circumventing many obstacles to ultrasound deployment. DESIGN Pilot study. SETTING Study activities took place in five health centres in rural Peru. PARTICIPANTS There were 213 participants presenting to rural health clinics. INTERVENTIONS Individuals without prior ultrasound experience in rural Peru underwent brief training on how to use the teleultrasound system and perform lung ultrasound VSI. Subsequently, patients attending clinic were scanned by these previously ultrasound-naïve operators with the teleultrasound system. PRIMARY AND SECONDARY OUTCOME MEASURES Radiologists examined the ultrasound imaging to assess its diagnostic value and identify any pathology. A random subset of 20% of the scans were analysed for inter-reader reliability. RESULTS Lung VSI teleultrasound examinations underwent detailed analysis by two cardiothoracic attending radiologists. Of the examinations, 202 were rated of diagnostic image quality (94.8%, 95% CI 90.9% to 97.4%). There was 91% agreement between radiologists on lung ultrasound interpretation among a 20% sample of all examinations (κ=0.76, 95% CI 0.53 to 0.98). Radiologists were able to identify sequelae of COVID-19 with the predominant finding being B-lines. CONCLUSION Lung VSI teleultrasound performed by individuals without prior training allowed diagnostic imaging of the lungs and identification of sequelae of COVID-19 infection. Deployment of lung VSI teleultrasound holds potential as a low-cost means to improve access to imaging around the world.
Collapse
Affiliation(s)
- Thomas J Marini
- University of Rochester Medical Center, Rochester, New York, USA
| | | | - Robert Ambrosini
- University of Rochester Medical Center, Rochester, New York, USA
| | - Timothy M Baran
- University of Rochester Medical Center, Rochester, New York, USA
| | - Ann M Dozier
- University of Rochester Medical Center, Rochester, New York, USA
| | - Yu T Zhao
- University of Rochester Medical Center, Rochester, New York, USA
| | | | | | | | | | | |
Collapse
|
15
|
Bo XW, Sun LP, Wan J, Sun YK, Zhang YQ, He T, Qian ZB, Qin C, Guo LH, Xu HX. Accuracy of point-of-care tele-ultrasonography for assisting ultrasound-naive resident doctors in detecting lower-limb deep venous thrombosis: A prospective controlled trial. Biomed Signal Process Control 2022. [DOI: 10.1016/j.bspc.2022.103738] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/07/2022]
|
16
|
Chai HH, Ye RZ, Xiong LF, Xu ZN, Chen X, Xu LJ, Hu X, Jiang LF, Peng CZ. Successful Use of a 5G-Based Robot-Assisted Remote Ultrasound System in a Care Center for Disabled Patients in Rural China. Front Public Health 2022; 10:915071. [PMID: 35923952 PMCID: PMC9339711 DOI: 10.3389/fpubh.2022.915071] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/07/2022] [Accepted: 06/22/2022] [Indexed: 12/07/2022] Open
Abstract
Background Disability has become a global population health challenge. Due to difficulties in self-care or independent living, patients with disability mainly live in community-based care centers or institutions for long-term care. Nonetheless, these settings often lack basic medical resources, such as ultrasonography. Thus, remote ultrasonic robot technology for clinical applications across wide regions is imperative. To date, few experiences of remote diagnostic systems in rural care centers have been reported. Objective To assess the feasibility of a fifth-generation cellular technology (5G)-based robot-assisted remote ultrasound system in a care center for disabled patients in rural China. Methods Patients underwent remote robot-assisted and bedside ultrasound examinations of the liver, gallbladder, spleen, and kidneys. We compared the diagnostic consistency and differences between the two modalities and evaluated the examination duration, image quality, and safety. Results Forty-nine patients were included (21 men; mean age: 61.0 ± 19.0 [range: 19-91] years). Thirty-nine and ten had positive and negative results, respectively; 67 lesions were detected. Comparing the methods, 41 and 8 patients had consistent and inconsistent diagnoses, respectively. The McNemar and kappa values were 0.727 and 0.601, respectively. The mean duration of remote and bedside examinations was 12.2 ± 4.5 (range: 5-26) min and 7.5 ± 1.8 (range: 5-13) min (p < 0.001), respectively. The median image score for original images on the patient side and transmitted images on the doctor side was 5 points (interquartile range: [IQR]: 4.7-5.0) and 4.7 points (IQR: 4.5-5.0) (p = 0.176), respectively. No obvious complications from the examination were reported. Conclusions A 5G-based robot-assisted remote ultrasound system is feasible and has comparable diagnostic efficiency to traditional bedside ultrasound. This system may provide a unique solution for basic ultrasound diagnostic services in primary healthcare settings.
Collapse
Affiliation(s)
- Hui-hui Chai
- Department of Medical Ultrasound, Shanghai Tenth People' Hospital, Tongji University School of Medicine, Shanghai, China
| | - Rui-zhong Ye
- Emergency and Critical Care Center, Department of Ultrasound Medicine, Zhejiang Provincial People's Hospital (Affiliated People's Hospital, Hangzhou Medical College), Hangzhou, China
| | - Lin-fei Xiong
- Department of Engineering, BGI Life Science Research Institution, Shenzhen, China
| | - Zi-ning Xu
- Emergency and Critical Care Center, Department of Ultrasound Medicine, Zhejiang Provincial People's Hospital (Affiliated People's Hospital, Hangzhou Medical College), Hangzhou, China
| | - Xuan Chen
- Department of Engineering, BGI Life Science Research Institution, Shenzhen, China
| | - Li-juan Xu
- Department of General Practice, Yuanshu Disabled Care Center, Huzhou, China
| | - Xin Hu
- Department of General Practice, Yuanshu Disabled Care Center, Huzhou, China
| | - Lian-feng Jiang
- Department of General Practice, Yuanshu Disabled Care Center, Huzhou, China
| | - Cheng-zhong Peng
- Department of Medical Ultrasound, Shanghai Tenth People' Hospital, Tongji University School of Medicine, Shanghai, China
- Ultrasound Research and Education Institute, Clinical Research Center for Interventional Medicine, Tongji University School of Medicine, Shanghai, China
- Shanghai Engineering Research Center of Ultrasound Diagnosis and Treatment, Shanghai, China
| |
Collapse
|
17
|
Alarcon R, Romero SE, Guevara N, Montoya X, Rios G, Terrones R, Marini TJ, Castaneda B. Panoramic Reconstruction of B-mode Lung Ultrasound Images Acquired using a Longitudinal Volume Sweep Imaging Protocol. ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY. IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY. ANNUAL INTERNATIONAL CONFERENCE 2022; 2022:3903-3906. [PMID: 36085702 DOI: 10.1109/embc48229.2022.9871438] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/15/2023]
Abstract
The ongoing COVID-19 pandemic has already affected more than 300 million people worldwide. Medical imaging shortage affects an estimated of 4 billion people, especially in rural and remote areas (RAs), limiting diagnostic assessment of respiratory illness. Lung ultrasound imaging (LUS) together with volume sweep imaging (VSI) acquisition protocols have been successfully piloted as a solution for lung screening in RAs eliminating the need for trained operators and on-site radiologists. Nevertheless, this protocol requires the acquisition of 12 videos for 6 areas with both longitudinal and transverse positions of the transducer. Nonetheless, bandwidth limitations can hamper the transmission of these videos for remote interpretation. This work aimed to developed a stitching algorithm capable of generating a panoramic reconstruction of LUS cine clips. The results show reconstructions with minimal loss of information as 92.5% of the panoramic images conserved the presence of A-lines. These results show that LUS can be represented as an image without significantly compromising its quality. This can be useful to overcome bandwidth issues as well as improve the time on lung assessment of the patient.
Collapse
|
18
|
Uschnig C, Recker F, Blaivas M, Dong Y, Dietrich CF. Tele-ultrasound in the Era of COVID-19: A Practical Guide. ULTRASOUND IN MEDICINE & BIOLOGY 2022; 48:965-974. [PMID: 35317949 PMCID: PMC8743597 DOI: 10.1016/j.ultrasmedbio.2022.01.001] [Citation(s) in RCA: 9] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 07/27/2021] [Revised: 12/21/2021] [Accepted: 01/04/2022] [Indexed: 06/14/2023]
Abstract
Telemedicine has evolved over the past 50 years, with video consultations and telehealth (TH) mobile apps that are now widely used to support care in the management of chronic conditions, but are infrequently used in acute conditions such as emergencies. In the wake of the COVID-19 pandemic, demand is growing for video consultations as they minimize health provider-patient interactions and thereby the risk of infection. Advanced applications such as tele-ultrasound (TUS) have not yet gained a foothold despite their achieving technical maturity and the availability of software from numerous companies for TUS for their respective portable ultrasound devices. However, ultrasound is indispensable for triage in emergencies and also offers distinct advantages in the diagnosis of COVID-19 pneumonia for certain patient populations such as pregnant women, children and immobilized patients. Additionally, recent work suggests lung ultrasound can accurately risk stratify patients for likely infection when immediate polymerase chain reaction (PCR) testing is not available and has prognostic utility for positive patients with respect to the need for admission and intensive care unit (ICU) treatment. Though currently underutilized, a wider implementation of TUS in TH applications and processes may be an important stepping-stone for telemedicine. The addition of ultrasound to TH may allow it to cross the barrier from being an application used mainly for primary care and chronic conditions to an indispensable tool used in emergency care, disaster situations, remote areas and low-income countries where it is difficult to obtain high-quality diagnostic imaging. The objective of this review was to provide an overview of the current state of telemedicine, insights into current and future use scenarios, its practical application as well as current TUS uses and their potential value with an overview of currently available portable and handheld ultrasound devices. In the wake of the COVID-19 pandemic we point out an unmet need and use case of TUS as a supportive tool for health care providers and organizations in the management of affected patients.
Collapse
Affiliation(s)
- Christopher Uschnig
- Department of Internal Medicine, Clinics Beau-Site, Salem and Permanence, Bern, Switzerland.
| | - Florian Recker
- Department of Obstetrics and Prenatal Medicine, University Hospital Bonn, Venusberg Campus, Germany
| | - Michael Blaivas
- Department of Emergency Medicine, St. Francis Hospital, University of South Carolina School of Medicine, Columbus, Georgia, USA
| | - Yi Dong
- Department of Ultrasound, Zhongshan Hospital, Fudan University, Shanghai, China
| | - Christoph F Dietrich
- Department of Internal Medicine, Clinics Beau-Site, Salem and Permanence, Bern, Switzerland
| |
Collapse
|
19
|
Arroyo J, Marini TJ, Saavedra AC, Toscano M, Baran TM, Drennan K, Dozier A, Zhao YT, Egoavil M, Tamayo L, Ramos B, Castaneda B. No sonographer, no radiologist: New system for automatic prenatal detection of fetal biometry, fetal presentation, and placental location. PLoS One 2022; 17:e0262107. [PMID: 35139093 PMCID: PMC8827457 DOI: 10.1371/journal.pone.0262107] [Citation(s) in RCA: 16] [Impact Index Per Article: 5.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/20/2021] [Accepted: 12/17/2021] [Indexed: 02/06/2023] Open
Abstract
Ultrasound imaging is a vital component of high-quality Obstetric care. In rural and under-resourced communities, the scarcity of ultrasound imaging results in a considerable gap in the healthcare of pregnant mothers. To increase access to ultrasound in these communities, we developed a new automated diagnostic framework operated without an experienced sonographer or interpreting provider for assessment of fetal biometric measurements, fetal presentation, and placental position. This approach involves the use of a standardized volume sweep imaging (VSI) protocol based solely on external body landmarks to obtain imaging without an experienced sonographer and application of a deep learning algorithm (U-Net) for diagnostic assessment without a radiologist. Obstetric VSI ultrasound examinations were performed in Peru by an ultrasound operator with no previous ultrasound experience who underwent 8 hours of training on a standard protocol. The U-Net was trained to automatically segment the fetal head and placental location from the VSI ultrasound acquisitions to subsequently evaluate fetal biometry, fetal presentation, and placental position. In comparison to diagnostic interpretation of VSI acquisitions by a specialist, the U-Net model showed 100% agreement for fetal presentation (Cohen's κ 1 (p<0.0001)) and 76.7% agreement for placental location (Cohen's κ 0.59 (p<0.0001)). This corresponded to 100% sensitivity and specificity for fetal presentation and 87.5% sensitivity and 85.7% specificity for anterior placental location. The method also achieved a low relative error of 5.6% for biparietal diameter and 7.9% for head circumference. Biometry measurements corresponded to estimated gestational age within 2 weeks of those assigned by standard of care examination with up to 89% accuracy. This system could be deployed in rural and underserved areas to provide vital information about a pregnancy without a trained sonographer or interpreting provider. The resulting increased access to ultrasound imaging and diagnosis could improve disparities in healthcare delivery in under-resourced areas.
Collapse
Affiliation(s)
- Junior Arroyo
- Laboratorio de Imágenes Médicas, Departamento de Ingeniería, Pontificia Universidad Católica del Perú, Lima, Peru
| | - Thomas J. Marini
- Department of Imaging Sciences, University of Rochester Medical Center, Rochester, New York, United States of America
| | - Ana C. Saavedra
- Laboratorio de Imágenes Médicas, Departamento de Ingeniería, Pontificia Universidad Católica del Perú, Lima, Peru
| | - Marika Toscano
- Department of Obstetrics and Gynecology, University of Rochester Medical Center, Rochester, New York, United States of America
| | - Timothy M. Baran
- Department of Imaging Sciences, University of Rochester Medical Center, Rochester, New York, United States of America
| | - Kathryn Drennan
- Department of Obstetrics and Gynecology, University of Rochester Medical Center, Rochester, New York, United States of America
| | - Ann Dozier
- Department of Public Health, University of Rochester Medical Center, Rochester, New York, United States of America
| | - Yu Tina Zhao
- Department of Imaging Sciences, University of Rochester Medical Center, Rochester, New York, United States of America
| | - Miguel Egoavil
- Research & Development, Medical Innovation & Technology, Lima, Perú
| | - Lorena Tamayo
- Research & Development, Medical Innovation & Technology, Lima, Perú
| | - Berta Ramos
- Department of Imaging Sciences, University of Rochester Medical Center, Rochester, New York, United States of America
| | - Benjamin Castaneda
- Laboratorio de Imágenes Médicas, Departamento de Ingeniería, Pontificia Universidad Católica del Perú, Lima, Peru
| |
Collapse
|
20
|
Marini TJ, Weis JM, Baran TM, Kan J, Meng S, Yeo A, Zhao YT, Ambrosini R, Cleary S, Rubens D, Chess M, Castaneda B, Dozier A, O'Connor T, Garra B, Kaproth-Joslin K. Lung ultrasound volume sweep imaging for respiratory illness: a new horizon in expanding imaging access. BMJ Open Respir Res 2021; 8:8/1/e000919. [PMID: 34772730 PMCID: PMC8593737 DOI: 10.1136/bmjresp-2021-000919] [Citation(s) in RCA: 11] [Impact Index Per Article: 2.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/16/2021] [Accepted: 10/19/2021] [Indexed: 12/12/2022] Open
Abstract
Background Respiratory illness is a leading cause of morbidity in adults and the number one cause of mortality in children, yet billions of people lack access to medical imaging to assist in its diagnosis. Although ultrasound is highly sensitive and specific for respiratory illness such as pneumonia, its deployment is limited by a lack of sonographers. As a solution, we tested a standardised lung ultrasound volume sweep imaging (VSI) protocol based solely on external body landmarks performed by individuals without prior ultrasound experience after brief training. Each step in the VSI protocol is saved as a video clip for later interpretation by a specialist. Methods Dyspneic hospitalised patients were scanned by ultrasound naive operators after 2 hours of training using the lung ultrasound VSI protocol. Separate blinded readers interpreted both lung ultrasound VSI examinations and standard of care chest radiographs to ascertain the diagnostic value of lung VSI considering chest X-ray as the reference standard. Comparison to clinical diagnosis as documented in the medical record and CT (when available) were also performed. Readers offered a final interpretation of normal, abnormal, or indeterminate/borderline for each VSI examination, chest X-ray, and CT. Results Operators scanned 102 subjects (0–89 years old) for analysis. Lung VSI showed a sensitivity of 93% and a specificity of 91% for an abnormal chest X-ray and a sensitivity of 100% and a specificity of 93% for a clinical diagnosis of pneumonia. When any cases with an indeterminate rating on chest X-ray or ultrasound were excluded (n=38), VSI lung ultrasound showed 92% agreement with chest X-ray (Cohen’s κ 0.83 (0.68 to 0.97, p<0.0001)). Among cases with CT (n=21), when any ultrasound with an indeterminate rating was excluded (n=3), there was 100% agreement with VSI. Conclusion Lung VSI performed by previously inexperienced ultrasound operators after brief training showed excellent agreement with chest X-ray and high sensitivity and specificity for a clinical diagnosis of pneumonia. Blinded readers were able to identify other respiratory diseases including pulmonary oedema and pleural effusion. Deployment of lung VSI could benefit the health of the global community.
Collapse
Affiliation(s)
| | | | | | - Jonah Kan
- University of Rochester School of Medicine and Dentistry, URMC, Rochester, NY, USA
| | - Steven Meng
- University of Rochester School of Medicine and Dentistry, URMC, Rochester, NY, USA
| | - Alex Yeo
- Department of Medicine, Boston University Medical Center, Boston, MA, USA
| | - Yu T Zhao
- Department of Imaging Sciences, URMC, Rochester, NY, USA
| | | | - Sean Cleary
- Department of Imaging Sciences, URMC, Rochester, NY, USA
| | - Deborah Rubens
- Department of Imaging Sciences, URMC, Rochester, NY, USA
| | - Mitchell Chess
- Department of Imaging Sciences, URMC, Rochester, NY, USA
| | - Benjamin Castaneda
- Departmento de Ingeniería, Pontificia Universidad Católica del Perú, Lima, Peru
| | - Ann Dozier
- Department of Public Health Sciences, URMC, Rochester, NY, USA
| | | | - Brian Garra
- Medical Imaging Ministries of the Americas, Clermont, FL, USA
| | | |
Collapse
|