1
|
Ruiter S, Bard D, Ben Jeddi H, Saunders J, Snawder J, Warren N, Gorce JP, Cauda E, Kuijpers E, Pronk A. Exposure Monitoring Strategies for Applying Low-Cost PM Sensors to Assess Flour Dust in Industrial Bakeries. Ann Work Expo Health 2023; 67:379-391. [PMID: 36617226 DOI: 10.1093/annweh/wxac088] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/20/2022] [Accepted: 11/23/2022] [Indexed: 01/09/2023] Open
Abstract
Low-cost particulate matter (PM) sensors provide new methods for monitoring occupational exposure to hazardous substances, such as flour dust. These devices have many possible benefits, but much remains unknown about their performance for different exposure monitoring strategies in the workplace. We explored the performance of PM sensors for four different monitoring strategies (time-weighted average and high time resolution, each quantitative and semi-quantitative) for assessing occupational exposure using low-cost PM sensors in a field study in the industrial bakery sector. Measurements were collected using four types of sensor (PATS+, Isensit, Airbeam2, and Munisense) and two reference devices (respirable gravimetric samplers and an established time-resolved device) at two large-scale bakeries, spread over 11 participants and 6 measurement days. Average PM2.5 concentrations of the low-cost sensors were compared with gravimetric respirable concentrations for 8-h shift periods and 1-min PM2.5 concentrations of the low-cost sensors were compared with time-resolved PM2.5 data from the reference device (quantitative monitoring strategy). Low-cost sensors were also ranked in terms of exposure for 8-h shifts and for 15-min periods with a shift (semi-quantitative monitoring strategy). Environmental factors and methodological variables, which can affect sensor performance, were investigated. Semi-quantitative monitoring strategies only showed more accurate results compared with quantitative strategies when these were based on shift-average exposures. The main factors that influenced sensor performance were the type of placement (positioning the devices stationary versus personal) and the company or workstation where measurements were collected. Together, these findings provide an overview of common strengths and drawbacks of low-cost sensors and different ways these can be applied in the workplace. This can be used as a starting point for further investigations and the development of guidance documents and data analysis methods.
Collapse
Affiliation(s)
- Sander Ruiter
- Netherlands Organization for Applied Scientific Research (TNO), Healthy Living and Work, RAPID 3584 CB Utrecht, The Netherlands
| | - Delphine Bard
- Health and Safety Executive (HSE), HSE Science and Research Centre, Harpur Hill, Buxton SK17 9JN, UK
| | - Hasnae Ben Jeddi
- Netherlands Organization for Applied Scientific Research (TNO), Healthy Living and Work, RAPID 3584 CB Utrecht, The Netherlands
| | - John Saunders
- Health and Safety Executive (HSE), HSE Science and Research Centre, Harpur Hill, Buxton SK17 9JN, UK
| | - John Snawder
- Centers for Disease Control and Prevention, National Institute for Occupational Safety and Health (NIOSH), 1090 Tusculum Avenue, Cincinnati, OH 45226, USA
| | - Nick Warren
- Health and Safety Executive (HSE), HSE Science and Research Centre, Harpur Hill, Buxton SK17 9JN, UK
| | - Jean-Philippe Gorce
- Health and Safety Executive (HSE), HSE Science and Research Centre, Harpur Hill, Buxton SK17 9JN, UK
| | - Emanuele Cauda
- Centers for Disease Control and Prevention, National Institute for Occupational Safety and Health (NIOSH), 1090 Tusculum Avenue, Cincinnati, OH 45226, USA
| | - Eelco Kuijpers
- Netherlands Organization for Applied Scientific Research (TNO), Healthy Living and Work, RAPID 3584 CB Utrecht, The Netherlands
| | - Anjoeka Pronk
- Netherlands Organization for Applied Scientific Research (TNO), Healthy Living and Work, RAPID 3584 CB Utrecht, The Netherlands
| |
Collapse
|
2
|
Glenn K, He J, Rochlin R, Teng S, Hecker JG, Novosselov I. Assessment of aerosol persistence in ICUs via low-cost sensor network and zonal models. Sci Rep 2023; 13:3992. [PMID: 36899063 PMCID: PMC10006437 DOI: 10.1038/s41598-023-30778-7] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/19/2022] [Accepted: 03/01/2023] [Indexed: 03/12/2023] Open
Abstract
The COVID-19 pandemic raised public awareness about airborne particulate matter (PM) due to the spread of infectious diseases via the respiratory route. The persistence of potentially infectious aerosols in public spaces and the spread of nosocomial infections in medical settings deserve careful investigation; however, a systematic approach characterizing the fate of aerosols in clinical environments has not been reported. This paper presents a methodology for mapping aerosol propagation using a low-cost PM sensor network in ICU and adjacent environments and the subsequent development of the data-driven zonal model. Mimicking aerosol generation by a patient, we generated trace NaCl aerosols and monitored their propagation in the environment. In positive (closed door) and neutral-pressure (open door) ICUs, up to 6% or 19%, respectively, of all PM escaped through the door gaps; however, the outside sensors did not register an aerosol spike in negative-pressure ICUs. The K-means clustering analysis of temporospatial aerosol concentration data suggests that ICU can be represented by three distinct zones: (1) near the aerosol source, (2) room periphery, and (3) outside the room. The data suggests two-phase plume behavior: dispersion of the original aerosol spike throughout the room, followed by an evacuation phase where "well-mixed" aerosol concentration decayed uniformly. Decay rates were calculated for positive, neutral, and negative pressure operations, with negative-pressure rooms clearing out nearly twice as fast. These decay trends closely followed the air exchange rates. This research demonstrates the methodology for aerosol monitoring in medical settings. This study is limited by a relatively small data set and is specific to single-occupancy ICU rooms. Future work needs to evaluate medical settings with high risks of infectious disease transmission.
Collapse
Affiliation(s)
- K Glenn
- Department of Mechanical Engineering, University of Washington, Seattle, USA
| | - J He
- Department of Mechanical Engineering, University of Washington, Seattle, USA
| | - R Rochlin
- Department of Mechanical Engineering, University of Washington, Seattle, USA
| | - S Teng
- Department of Mechanical Engineering, University of Washington, Seattle, USA
| | - J G Hecker
- Department of Anesthesiology and Pain Medicine, University of Washington, Seattle, USA
| | - I Novosselov
- Department of Mechanical Engineering, University of Washington, Seattle, USA.
| |
Collapse
|